1 SINGLE STATION CARBON MONOXIDE ALARM Carbon Monoxide Alarm User Guide Model: KN-COP-DP-10YHCA ( CA) AC Plug-in Operated with Sealed Lithium Battery Backup with LED Nightlight ATTENTION: Please take a few minutes to thoroughly read this user guide which should be saved for future reference and passed on to any subsequent owner. P/N EN
2 What to do When the Alarm Sounds! Carbon Monoxide Alarm Procedure If alarm sounds 4 quick beeps, 5 seconds off: 1) Immediately move to fresh air - outdoors or by an open door/ window. Do a head count to check that all persons are accounted for. Do not re-enter the premises nor move away from the open door/window until the emergency services responders have arrived, the premises have been aired out, and your alarm remains in its normal condition. 2) Call your emergency services (Fire Department or 911); PHONE NUMBER: WARNING: Activation of the CO Alarm indicates the presence of Carbon Monoxide (CO) which can kill you. Never restart the source of a CO problem until it has been corrected. Never ignore the sound of the alarm! If the alarm is sounding, pressing the test/reset button will terminate the alarm. If the CO condition that caused the alert in the first place continues, the alarm will reactivate. If the unit alarms again within six minutes, it is sensing high levels of CO which can quickly become a dangerous situation.
3 Welcome Note: Many times throughout this User Guide, we will refer to Carbon Monoxide as CO. This Kidde carbon monoxide (CO) alarm is an important part of your family s home safety plan. This alarm has been designed and tested to detect CO buildup in a residential environment. Your alarm is for use specifically in the home, but not for use in a boat or recreational vehicle. As an owner of a CO alarm, there are some basic facts you should know about for your protection. Many people think that CO alarms operate like smoke alarms. Like smoke alarms, CO alarms monitor the air in your home and sound a loud alarm to warn you of trouble. The way you respond to a CO alarm is quite different than a smoke alarm. That s because a house fire and a CO problem are two distinctly different situations. If your smoke alarm were to alarm, you would quickly be able to judge the level of danger you were in with your senses. You can see and smell the smoke, feel the heat, see, and possibly hear the fire burning. You can also readily see if your smoke alarm is alarming in a non-emergency situation. Because your sense of sight, smell, hearing and touch give you information, you can almost instantly judge what action to take if you hear your smoke alarm. CO is an invisible, odorless, tasteless and non-irritating gas completely undetectable to your senses. That s why it is important to your safety that you have a CO alarm. Important Warning Statements IMPORTANT: This carbon monoxide alarm is designed to detect carbon monoxide from ANY source of combustion. It is NOT designed to detect smoke, fire, or any other gas. WARNING: Carbon monoxide alarms are not smoke alarms. This carbon monoxide alarm is not a substitute for installing and maintaining an appropriate number of smoke alarms in your home. This carbon monoxide alarm will not sense smoke, fire, or any poisonous gas other than carbon monoxide even though carbon monoxide can be generated by fire. For this reason you must install smoke alarms to provide early warning of fire and to protect you and your family from fire and its related hazards.! CAUTION: This alarm will only indicate the presence of carbon monoxide at the sensor. Carbon monoxide may be present in other areas.
4 Important Warning Statements WARNING: This product is intended for use in ordinary indoor locations of family living units, not for use in boats or recreational vehicles. It is not designed to measure compliance with commercial or industrial standards. It is not suitable for installation in hazardous locations as defined in your local building code. The installation of this device should not be used as a substitute for proper installation, use and maintenance of fuel burning appliances, including appropriate ventilation and exhaust systems. It does not prevent CO from occurring, nor can it solve an existing CO problem. WARNING: This device is designed to protect individuals from acute effects of carbon monoxide exposure. It may not fully safeguard individuals with specific medical conditions. If in doubt, consult a medical practitioner. Individuals with medical problems may consider using warning devices which provide audible and visual signals for carbon monoxide concentrations under 30 PPM. This carbon monoxide alarm requires a continuous supply of electrical power it will not work without power. Models without battery backup will not operate during power failure. This alarm has not been investigated for carbon monoxide detection below 70 PPM. Contents of This User Guide 1. Information About Carbon Monoxide 2. Product Features and Specifications 3. Installation Locations 4. Installation Instructions 5. Alarm Characteristics 6. Operating Characteristics 7. Maintenance 8. Limited Warranty
5 1. Information About Carbon Monoxide General Carbon Monoxide Information Carbon monoxide is a colorless, odorless and tasteless poison gas that can be fatal when inhaled. CO inhibits the blood s capacity to carry oxygen. Periodically review this alarm user guide and discuss your CO alarm emergency procedure with all the members of your family. Never ignore a CO alarm. A true alarm is an indication of potentially dangerous levels of CO. CO alarms are designed to alert you to the presence of CO before an emergency before most people would experience symptoms of CO poisoning, giving you time to resolve the problem calmly. Determine if anyone in the household is experiencing symptoms of CO poisoning. Many cases of reported CO poisoning indicate that while victims are aware they are not well, they become so disoriented they are unable to save themselves by either exiting the building or calling for assistance. Also, young children and household pets may be the first affected. You should take extra precautions to protect high-risk persons from CO exposure because they may experience ill effects from CO at levels that would not ordinarily affect a healthy adult. Symptoms of CO Poisoning The following common symptoms are related to CO poisoning and should be discussed with ALL members of the household. Mild Exposure: Slight headache, nausea, vomiting, fatigue (often described as flu-like symptoms). Medium Exposure: Severe throbbing headache, drowsiness, confusion, fast heart rate. Extreme Exposure: Unconsciousness, convulsions, cardio-respiratory failure, death. If you experience even mild symptoms of CO poisoning, consult your doctor immediately!
6 1. Information About Carbon Monoxide Carbon Monoxide PPM Levels Model KN-COP-DP-10YHCA is equipped with a digital display that shows levels of CO (displayed in PPM parts per million). Learn the difference between dangerous, high, mid and low levels. Dangerous Levels: When someone is experiencing symptoms of CO poisoning and CO readings are generally above 100 PPM. Anytime someone is experiencing the symptoms of CO poisoning this should be treated as an emergency. See What to do When the Alarm Sounds (inside front cover). High Levels: Generally above 100 PPM, with no one experiencing symptoms. This should be treated as an urgent situation. See What to do When the Alarm Sounds (inside front cover). Mid Levels: Generally between 50 PPM to 100 PPM. This should be cause for concern and should not be ignored or dismissed. See What to do When the Alarm Sounds (inside front cover). Low Levels: Generally below 50 PPM. Kidde recommends you take action to eliminate the source of CO. See What to do When the Alarm Sounds (inside front cover). Possible Sources of Carbon Monoxide Inside your home, appliances used for heating and cooking are the most likely sources of CO. Vehicles running in attached garages can also produce dangerous levels of CO. CO can be produced when burning any fossil fuel, such as gasoline, propane, natural gas, oil and wood. It can be produced by any fuel-burning appliance that is malfunctioning, improperly installed, or not ventilated correctly, such as: Automobiles, furnaces, gas ranges/stoves, gas clothes dryers, water heaters, portable fuel burning space heaters and generators, fireplaces, wood-burning stoves and certain swimming pool heaters. Blocked chimneys or flues, back drafts and changes in air pressure, corroded or disconnected vent pipes, loose or cracked furnace exchangers. Vehicles and other combustion engines running in an open or closed garage, attached or near a home. Burning charcoal or fuel in grills and hibachis in an enclosed area.
7 1. Information About Carbon Monoxide Conditions That Can Produce Carbon Monoxide The following conditions can result in transient CO situations: Excessive spillage or reverse venting of fuel-burning appliances caused by outdoor ambient conditions, such as, wind direction and/or velocity, including high gusts of wind, heavy air in the vent pipes (cold/humid air with extended periods between cycles). Negative pressure resulting from the use of exhaust fans. Simultaneous operation of several fuel-burning appliances competing for limited internal air. Vent pipe connections vibrating loose from clothes dryers, furnaces, or water heaters. Obstructions in, or unconventional, vent pipe designs which can amplify the above situations. Extended operation of unvented fuel-burning devices (range, oven, fireplace, etc.). Temperature inversions which can trap exhaust gases near the ground. Vehicle idling in an open or closed garage, or near a home. To be safe, know the possible sources of CO in your home. Keep fuelburning appliances and their chimneys and vents in good working condition. Learn the early symptoms of exposure, and if you suspect CO poisoning, move outside to fresh air and get emergency help. Your first line of defense is an annual inspection and regular maintenance of your appliances. Contact a licensed contractor or call your local utility company for assistance. Information About Carbon Monoxide Alarms What They Can and Cannot Do: CO alarms provide early warning of the presence of CO, usually before a healthy adult would experience symptoms. This early warning is possible, however, only if your CO alarm is located, installed and maintained as described in this guide. Because carbon monoxide is a cumulative poison, long-term exposures to low levels may cause symptoms, as well as short-term exposures to high levels. This Kidde unit has a time-weighted alarm the higher the level of CO present, the sooner the alarm will be triggered. This CO alarm can only warn you of the presence of CO. It does not prevent CO from occurring, nor can it solve an existing CO problem. If your unit has alarmed and you ve provided ventilation by leaving your windows and doors open, the CO buildup may have dissipated by the time help responds. Although your problem may appear to be temporarily solved, it s crucial that the source of the CO is determined and that the appropriate repairs are made.
8 1. Information About Carbon Monoxide This CO alarm is designed to act as a monitor; it is not designed for use as a short-term testing device to perform a quick check for the presence of CO. CO alarms have limitations. Like any other electronic device, CO alarms are not fool-proof. CO alarms have a limited operational life. You must test your CO alarm weekly, because it could fail to operate at any time. If your CO alarm fails to test properly, or if its self-diagnostic test reveals a malfunction, immediately have the unit replaced. This alarm will not monitor CO levels while in an error condition. CO alarms can only sense CO that reaches the unit s sensor. It s possible that CO may be present in other areas without reaching the alarm. The rate and ability that which CO reaches the alarm may be affected by: Doors or other obstructions. Fresh air from a vent, an open window or other source. CO being present on one level of the home and not reach a CO alarm installed on a different level. (For example, CO in the basement may not reach an alarm on the second level, near the bedrooms). For these reasons, we recommend you provide complete coverage by placing a CO alarm on every level of the home. Please carefully read all information on properly installing this CO alarm. CO alarms should not be used to detect the presence of natural gas (methane), propane, butane, or other combustible fuels. 2. Product Features and Specifications Temperature: Operating Range: 4.4 C (40 F) to 37.8 C (100 F) Humidity: Operating range: 10-95% relative humidity (RH), non-condensing Audible Alarm: 85+ db at 3.4±0.5 KHz pulsing alarm Sensor: Electrochemical Power: 120 volts AC, 60 Hz, 90 ma max, 3 volt sealed lithium battery back-up Alarm Response Times: 70 PPM = min., 150 PPM = min., 400 PPM = 4-15 min.
9 2. Product Features and Specifications Model KN-COP-DP-10YHCA Alarm Sounder Rotating AC Plug Deactivation / Discharge Switch Digital Display Cover Red Alarm Light Test/Hush Button Green Operate Light / Ambient Light Sensor Peak Level / Light Adjust Nightlight / Escape Light LED Low Battery Warning If the battery power is low, the unit will chirp every 60 seconds, and the display will show Lb to indicate the alarm must be replaced. THE ALARM MUST BE REPLACED IMMEDIATELY! Low Battery HUSH CONTROL When the unit produces a low battery warning, the Low Battery HUSH feature allows you to press the Test/Hush button on the alarm and disable the chirp for a period of approximately 10 hours. This gives you a chance to replace the alarm at a more convenient time without sacrificing your safety by disconnecting the alarm from power. During this Low Battery HUSH period, your alarm is monitoring for CO. If the alarm does not go into Low Battery Hush, the battery power is below the Low Battery Hush threshold. REPLACE THE ALARM IMMEDIATELY! Ambient Light Sensor This alarm includes a feature to determine dark or light conditions. This feature will; 1. Help prevent low battery chirping at night, (when ambient conditions are dark). 2. Dim the display in low light conditions, (night time and darker rooms), and brighten the display in bright light conditions. 3. Turn on the Nightlight LED in low light conditions, (unit must be plugged into AC for Night light operation).
10 2. Product Features and Specifications End of Unit Life Warning IMPORTANT: Ten (10) years after the initial power up, this alarm will beep two times every 30 seconds to indicate that it is time to replace the alarm. Display will show End. To help identify the date to replace the alarm, a label has been affixed to the side of the alarm. Write the replace by date (ten years from power up) in a permanent marker on this label. End of Unit Life Hush Control The End of unit Life Hush feature allows you to silence End of Unit life chirping, for a period of 3 days, by pressing the Test/Hush button. This feature can be used 10 times within 30 days, allowing you to replace the alarm at a more convenient time. After 30 days, the alarm will no longer detect CO. RELACE ALARM IMMEDIATELY! Night Light / Escape Light Feature This model is equipped with a night light feature. The brightness of the night light can be adjusted by the user pushing the peak level button and holding the button as the digital display cycles through a range of numbers (settings) from 0 to 10. Release the button at the desired setting number (brightness). If the night light feature is not wanted, push and hold the peak level button, and then release the button when the display cycles to the Off setting. Note: The night light feature does not work if the unit is powered by DC only. The escape light feature can help people exit rooms during alarm situations. The escape light will brightly illuminate during alarm, and will remain lit continuously on AC power as long as the alarm condition exists. On DC power only, the escape light will remain lit continuously as long as the alarm condition exists and the low battery level has not been reached.
11 3. Installation Locations Recommended Installation Locations CO alarms should be mounted in or near bedrooms and living areas. It is recommended that you install a Kidde CO alarm on each level of your home. When choosing your installation locations, make sure you can hear the alarm from all sleeping areas. If you install only one CO alarm in your home, install it near bedrooms, not in the basement or furnace room. DINING KITCHEN BEDROOM BEDROOM LIVING ROOM BEDROOM Recommended Locations The CO alarm plugs into a wall socket. Children must be taught not to handle the CO alarm. Locations To Avoid IMPORTANT: Improper location can affect the sensitive electronic components in this alarm. To avoid causing damage to the unit, to provide optimum performance, and to prevent unnecessary nuisance alarms: Do not install in kitchens, garages or furnace rooms that may expose the sensor to substances that could damage or contaminate it. Do not install in areas where the temperature is colder than 4.4 C (40 F) or hotter than 37.8 C (100 F) such as crawl spaces, attics, porches and garages. Do not install within 1.5 m (5 ) of heating or cooking appliances. (Kidde recommends 4.5 m (15 ) to prevent nuisance alarms). Do not install near vents, flues, chimneys or any forced/unforced air ventilation openings. Do not install near ceiling fans, doors, windows or areas directly exposed to the weather. Do not install in dead air spaces, such as peaks of vaulted ceilings or gabled roofs, where CO may not reach the sensor in time to provide early warning. Do not install this unit near deep-cell large batteries. Large batteries have emissions that can cause the alarm to perform at less than optimum performance. Do not obstruct the vents located on the alarm. Do not place the alarm where drapes, furniture or other objects block the flow of air to the vents.
12 4. Installation Instructions How to Install Your Alarm To install: 1. Remove the switch cover. 2. Choose a standard 120V unswitched outlet to plug the alarm into. 3. If outlet is mounted sideways (horizontally), rotate the plug and plug the alarm in. Note: This model is equipped with a feature that automatically activates the battery backup when the alarm is plugged into an AC outlet for the first time.! CAUTION: Do not rotate the alarm while it is plugged into an outlet, as damage to plug may result. 5. Alarm Characteristics Carbon Monoxide Alarm Indicator When the alarm senses a dangerous level of CO, the unit will emit a loud alarm pattern. The alarm pattern is 4 quick beeps followed by 5 seconds of silence. This cycle repeats as long as a dangerous CO conditions exist. The red Alarm LED will flash the same pattern, the Escape light will illuminate, and the PPM will be displayed on the digital display. The digital display will be brightly lit if the unit is in alarm. 90º ROTATING DIRECT PLUG WARNING: If at any time you test the alarm and it does not perform as described, have it replaced immediately. 6. Operating Characteristics When you first power up the alarm: The red Alarm LED will light and the alarm will chirp once. CO alarm power indicators: AC - Digital display constantly on. DC Only - Green LED flashes briefly once every 60 seconds. Within a few minutes, your carbon monoxide alarm will start monitoring for CO and will continue to do so as long as it receives power. Whenever the KN-COP-DP-10YHCA is operating, the digital display will display 0 (with AC applied) to indicate the unit is monitoring for CO. If the alarm senses dangerous levels of CO, the digital display will alternate between CO and the measured CO concentration in parts per million (PPM), and the alarm will emit an audible alarm pattern, and the Escape light will illuminate.
13 6. Operating Characteristics This alarm will display a 0 if CO concentrations between 0 and 30 PPM have been detected within the last 15 seconds. When the unit is first powered up, the digital display will show three eights indicating the alarm is in the start-up mode. The three eights will remain for approximately 5 seconds. After 5 seconds, the alarm should display 0 and begin monitoring the air for CO and will continue to do so as long as it receives power. The digital display will be brightly lit if the unit is in alarm, or in high light, and then will become dim in the standby condition during low light conditions. The Night light, in low light conditions with AC applied, will illuminate. The following table illustrates the possible digital displays, describes the audible alarm patterns, and the recommended actions to take. Operating and Alarm Characteristics LED Display Shows Alarm Sound Unit Status Recommendation An alternating display of CO and the CO concentration from Escape light is on. --- then 888. Escape light briefly lit. 4 quick beeps, 5 seconds silence, repeating Alarm condition. Dangerous concentrations of CO detected 4 quick beeps, Self checking (Test 5 seconds silence, button was pressed) repeated once Refer to What to do When the Alarm Sounds (inside front cover) None CO has not been detected. Steady 0 displayed. None Normal AC operation None (sensing no CO) and with a good battery. Display alternates between Lb and current CO level, (0-999) One quick beep every 60 seconds AC powered and in Low Battery condition Replace alarm. Steady Err displayed One quick beep every 30 seconds Unit malfunction If Err continues, unit has malfunctioned and must be replaced immediately. Unit will not respond to CO. Press the Peak Level button while unit is in Err mode to obtain error code and call Product Support line. An alternating display of PCO and the CO concentration (PPM) None Unit has detected 100ppm or more CO Push test/reset button, check appliances No display. Green LED flashes briefly once every 60 seconds. None Battery backup operation. Unit monitoring for CO. Verify AC power is restored as soon as possible to conserve battery. End displayed. Red LED flashes two times every 30 seconds 2 quick beeps every 30 seconds. End of unit life Replace unit immediately. Refer to Section 2 for End of Life Warning and Discharge section on the next page.
14 6. Operating Characteristics Peak Level Event Alert A Peak Level Event occurs whenever CO concentrations are greater than 100 PPM. The display will alternate between PCO and the currently measured CO concentration, (0-999), even if that concentration has returned to 0 PPM, (see Peak Level Memory section below to display peak level CO from the event). The display will alternate continuously on AC power, and will briefly display once every minute on DC only. 1. The unit goes into alarm or, 2. CO concentration level drops below 100 PPM AND the user clears the Peak CO Memory, (see Peak Level Memory Reset section below). If the CO concentration is greater than 30 PPM and less than 100 PPM, the display will indicate the measured CO concentration only. Peak Level Memory When the Peak Level button is pressed and held, the display shows the highest CO reading taken by the CO alarm since its last reset or power up. The Peak Level display feature will display levels between PPM. Although the Peak Level feature will display levels below 30 PPM, these levels will not result in an alarm no matter how long the device is exposed to these levels. The Peak Level feature is helpful in identifying if you have had a CO reading since resetting the alarm. Concentrations of CO between 1 and 30 PPM can often occur in normal, everyday conditions. Concentrations of CO below 30 PPM may be an indication of a transient condition that may appear today and never reappear. Some CO conditions may start out as low level leaks but could develop into CO concentrations that may become harmful. Peak Level Memory Reset Press and hold the Peak Level button, then press and hold the Test/ Hush button. When the number on the display reads 0, release both buttons. The memory will be cleared and the alarm will begin monitoring for CO. Discharge At end of unit life, locate the deactivation / discharge switch and push the switch in the direction shown, until switch clicks into place. This will silence the end of unit life or low battery chirping, drain the battery, and render the unit safe for disposal.
15 7. Maintenance NOTE: This unit is sealed. The cover is not removable. Due to the loudness of the alarm, we suggest that you place your fingers over the sounder opening while testing your alarm.! Caution: Continuous exposure to the high sound level of this alarm over an extended period of time may cause hearing loss. Testing To test the alarm, press the Test/Hush button. If the unit is operating properly, you will hear 4 quick beeps followed by 5 seconds of silence followed by 4 quick beeps. The display will show in sequence --- then 888, and the Escape light will illuminate. Within several seconds the unit will return to monitor for CO. Note: You do not need to press the Test button to take a CO reading. Maintenance Tips To keep your alarm in good working order, you must follow these steps: Test the alarm once a week by pressing the Test/Reset button. Vacuum the alarm cover once a month to remove accumulated dust. Never use detergents or solvents to clean the alarm. Chemicals can permanently damage or temporarily contaminate the sensor. Avoid spraying air fresheners, hair spray, paint or other aerosols near the alarm. Do not paint the unit. Paint will seal the vents and interfere with proper sensor operation. Move the CO Alarm to a remote location, to prevent possible damage or contamination of the sensor, prior to performing any of the following: Staining or stripping floors or furniture, painting or wall-papering Using aerosols or adhesives WARNING: Reinstall the CO Alarm as soon as possible to assure continuous protection. The following is a list of substances that at high levels can damage the sensor or cause temporary readings that are not CO readings: Ethylene, ethanol, alcohol, iso-propanol, benzene, toluene, ethyl acetate, hydrogen, hydrogen sulfide and sulfur dioxide. Also most aerosol sprays, alcohol based products, paint, thinner, solvent, adhesive, hair spray, after shave, perfume, auto exhaust (cold start) and some cleaning agents.
16 8. Limited Warranty Ten Year Limited Warranty If after reviewing this user guide you feel that your alarm is defective in any way, do not tamper with the unit. In many cases, the quickest way to exchange your alarm is to return it to the original place of purchase. Alternatively, you may return it for servicing to Kidde. If you have questions, call Kidde Customer Service at Kidde warrants that the enclosed alarm will be free from defects in material and workmanship or design under normal use and service for a period of ten years from the date of purchase. The obligation of Kidde under this warranty is limited to repairing or replacing the alarm or any part which we find to be defective in material, workmanship or design, free of charge, upon sending the alarm with proof of date of purchase, postage and return postage prepaid, to: Kidde Canada Inc., P.O. Box 40, Apsley, ON K0L 1A0. This warranty shall not apply to the alarm if it has been damaged, modified, abused or altered after the date of purchase or if it fails to operate due to improper maintenance or inadequate A.C. power. Any implied warranties arising out of this sale, including but not limited to the implied warranties of description,merchantability and fitness for a particular purpose, are limited in duration to the above warranty period. In no event shall the Manufacturer be liable for loss of use of this product or for any indirect, special, incidental or consequential damages, or costs, or expenses incurred by the consumer or any other user of this product, whether due to a breach of contract, negligence, strict liability in tort or otherwise. The Manufacturer shall have no liability for any personal injury, property damage or any special, incidental, contingent or consequential damage of any kind resulting from gas leakage, fire or explosion. Since some provinces do not allow limitations of the duration of an implied warranty or do not allow the exclusion or limitation of incidental or consequential damages, the above limitations or exclusions may not apply to you. While this warranty gives you specific legal rights, you may also have other rights which vary from province to province. The above warranty may not be altered except in writing signed by both parties hereto. IMPORTANT: Do not remove unit back cover. Back cover removal will void warranty. Your Kidde Carbon Monoxide Alarm is not a substitute for property, disability, life or other insurance of any kind. Appropriate insurance coverage is your responsibility. Consult your insurance agent. Kidde Canada Inc., P.O. Box 40, Apsley, ON K0L1A0 QUESTIONS OR FOR MORE INFORMATION Call our Consumer Hotline at or contact us at our website at
Carbon Monoxide Alarm User s Guide
Carbon Monoxide Alarm User s Guide 900-0235 and 900-0234 SINGLE STATION CARBON MONOXIDE ALARM Carbon Monoxide Alarm Carbon Monoxide Alarm 900-0235 KN-COB-DP-LS-CA 900-0234 KN-COP-DP-LS-CA with Digital
Carbon Monoxide Alarm User s Guide
Carbon Monoxide Alarm User s Guide Models: KN-COB-B-LPM and KN-COPP-B-LPM (with Digital Display) KN-COB-B-LPM KN-COPP-B-LPM with Digital Display Digital Display Peak Level Memory 3-AA Battery Operation
Carbon Monoxide Alarm User s Guide
Carbon Monoxide Alarm User s Guide Models: KN-COB-DP-LS and KN-COP-DP-LS Carbon Monoxide Alarm Carbon Monoxide Alarm KN-COB-DP-LS 120V AC Plug-In 9V Battery Backup Tamper Resist Feature KN-COP-DP-LS with
Carbon Monoxide and Explosive Gas Alarm User s Guide
Carbon Monoxide and Explosive Gas Alarm User s Guide Model: KN-COEG-3 (900-0113) SINGLE STATION CARBON MONOXIDE ALARM ALSO SUITABLE FOR USE AS A RESIDENTIAL GAS DETECTOR KN-COEG-3 with Digital Display
Carbon Monoxide Alarm User s Guide
Carbon Monoxide Alarm User s Guide 900-0099 900-0099 KN-COPP-3-RC with Digital Display AC Plug-in Operated with Self Recharging Battery Backup ATTENTION: Please take a few minutes to thoroughly read this
Carbon Monoxide Alarm User s Guide
SINGLE STATION CARBON MONOXIDE ALARM Carbon Monoxide Alarm User s Guide 900-0255 900-0255 KN-COPF-i-CA with Digital Display AC Plug-in Operated with Rechargeable Battery Backup ATTENTION: Please take a
TX-6310-01-1 Carbon Monoxide Alarm Manual
TX-6310-01-1 Carbon Monoxide Alarm Manual Figure 1: Alarm features Green Power LED Alarm sounder Test/Hush button Attention: Please take a few minutes to thoroughly read this guide which should be saved
Alarms. State of Wisconsin Rules ss. 101.149(2) and (3) Comm. 62.1200 Comm.21.097
Carbon Monoxide Alarms State of Wisconsin Rules ss. 101.149(2) and (3) Comm. 62.1200 Comm.21.097 Carbon Monoxide Hazards CO, is a colorless, odorless and tasteless, yet highly toxic gas. Its molecules
120 VAC, 60 Hz, 100 ma Maximum Single Station Carbon Monoxide Alarm Also suitable as a Residential Gas Detector
Models MCN400, MCN400L, MCND401, MCND401L Certified to Standards UL 2034 & UL 1484 Plug-In Carbon Monoxide & Natural Gas Alarm with Backup Battery Protection Models MCN600, MCN600L, MCND601, MCND601L Single
Macurco CM-E1 Carbon Monoxide Detector
Macurco CM-E1 Carbon Monoxide Detector User Instructions Important: These User Instructions are to be provided to the homeowner/end user upon product installation. Each person installing or using this
Carbon Monoxide. Alarm. User s Guide U L. Kidde CO Alarm with Digital Display and Peak Level Memory Model: KN-COPP-3
Carbon Monoxide See page 26 for What to do when the alarm sounds Alarm User s Guide Kidde CO Alarm with Digital Display and Peak Level Memory Model: KN-COPP-3 Please have the following information ready
User Guide for the Kidde RemoteLync. Remote Notification Device
User Guide for the Kidde RemoteLync Remote Notification Device 120V AC 3 Color LED Indicator Voice Message System For questions concerning your device, please call our Product Support Line at 1-800-880-6788.
Smoke and Carbon Monoxide Alarm
User s Guide for Model KN-COSM-B Combination Smoke and Carbon Monoxide Alarm Battery Operated 2-LED Display Hush Peak Level Memory For questions concerning your Smoke and Carbon Monoxide Alarm, please
! WARNING: RECREATIONAL VEHICLE (RV) Combination Carbon Monoxide and Gas Alarm USER S MANUAL Model 25-741 ABOUT THIS ALARM
RECREATIONAL VEHICLE (RV) Combination Carbon Monoxide and Gas Alarm USER S MANUAL Model 25-741 PATENT US 7,248,156 ALL RIGHTS RESERVED 25RV052013-1 ATTENTION: This user s manual contains important Carbon
OWNER S MANUAL for Models:
RU L E196731 LISTED DESIGN CERTIFIED IAS 6-96-2nd EDITION CO ALARM US R OWNER S MANUAL for Models: 7030SL 7035/7035SL 9 Volt Battery CO Alarm, Single Station 9 Volt Battery CO Alarm with LCD Digital Display
LOUTH COUNTY COUNCIL STATEMENT OF POLICY ON DOMESTIC FIRE DETECTION AND ALARM SYSTEMS
LOUTH COUNTY COUNCIL STATEMENT OF POLICY ON DOMESTIC FIRE DETECTION AND ALARM SYSTEMS Louth County Council as both a Housing and Fire Authority has a responsibility to encourage compliance and best practise
CO-220 Carbon Monoxide Meter
Page 1 CO-220 Carbon Monoxide Meter Instruction Sheet Introduction The CO-220 Carbon Monoxide Meter (hereafter referred to as the Meter ) detects the presence of carbon monoxide (CO) and measures concentrations
WTSL-SN-1 Alarm Control Unit with Wi-Safe 2 Installation and User Guide
WTSL-SN-1 Alarm Control Unit with Wi-Safe 2 Installation and User Guide "sona control unit install" For use with Wi-Safe 2 Smoke, Heat and Carbon Monoxide Alarms 1 PLEASE READ THIS GUIDE IN FULL BEFORE
Combination Smoke & Carbon Monoxide Alarm
120 V AC and 9 V Battery Backup Combination Smoke & Carbon Monoxide Alarm with Voice Alarm System, Hush, and Peak Level Memory Model KN-COSM-ICA (model KN-COSM-IBCA only) User s Guide Model KN-COSM-IBCA
INTRODUCTION USER S MANUAL
USER S MANUAL BATTERY OPERATED CARBON MONOXIDE ALARM WITH SILENCE FEATURE INTRODUCTION BASIC SAFETY INFORMATION Dangers, Warnings, and Cautions alert you to important operating instructions or to potentially
Sounding the Call Carbon Monoxide What You Need to Know
Sounding the Call Carbon Monoxide What You Need to Know Bob Scott NASCSP Energy Services Director CO Overview What We Will Talk About What is CO? What are the effects and at what levels? What are the symptoms?
Having a gas appliance installed or serviced? Doing home improvements?
Keeping you safe Having a gas appliance installed or serviced? Think Safety. Think RGI. In your home, safety comes first. If you are having a gas appliance installed, serviced or repaired, always use a
CO-9B User Manual CARBON MONOXIDE POISONOUS GAS ALARM
CO-9B User Manual CARBON MONOXIDE POISONOUS GAS ALARM CONTENTS INTRODUCTION FEATURES CARBON MONOXIDE AND HOW IT CAN AFFECT YOU AND YOUR FAMILY WHERE TO INSTALL YOUR DETECTOR 2 2 3 5 WHAT TO DO IN THE EVENT
INSTALLATION BASIC SAFETY INFORMATION USER S MANUAL PLUG-IN EXPLOSIVE GAS AND CARBON MONOXIDE ALARM WITH BATTERY BACK-UP AND SILENCE FEATURE
PLUG-IN EXPLOSIVE GAS AND CARBON MONOXIDE ALARM WITH BATTERY BACK-UP AND SILENCE FEATURE IMPORTANT! PLEASE READ CAREFULLY AND SAVE. This unit was shipped with a user s manual that contains important information
Natural Gas Safety. What You Need to Know
Natural Gas Safety What You Need to Know Knowledge is Safety Approximately 52% of all U.S. households use natural gas for Home heating Cooking Water heaters Gas logs Outdoor gas grills Our Local History
www.coned.com Natural Gas Safety What You Need To Know
www.coned.com Natural Gas Safety What You Need To Know We are committed to keeping our customers safe and we respond rapidly to any calls about gas leaks. We work with emergency responders to protect you.
EzFlex Combustible Gas Leak Detector Model EZ40
User's Guide EzFlex Combustible Gas Leak Detector Model EZ40 Introduction Congratulations on your purchase of the Extech EZ40 Combustible Gas Leak Detector. The EZ40 detects the presence of combustible
Smoke and Carbon Monoxide Alarm User Guide
SINGLE AND/OR MULTIPLE STATION SMOKE ALARM Smoke and Carbon Monoxide Alarm User Guide Model: KN-COSM-IBACA (900-0119) SINGLE AND/OR MULTIPLE STATION CARBON MONOXIDE ALARM 120 V AC Operated with 2-AA Front-Loading
Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors
Carbon Monoxide (CO) Detection PRODUCTS Accessories Conventional Detectors 2 Complete CO Detection The system-connected CO1224T and CO1224TR CO detectors with RealTest provide early warning by using reliable
Owner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
System-Connected Carbon Monoxide Detectors
A P P L I C A T I O N S G U I D E System-Connected Carbon Monoxide Detectors S Y S T E M S E N S O R System-Connected Carbon Monoxide Detectors Contents Introduction...2 Section 1: Standards That Apply...2
Mold Alert... Operation Manual P0270
Mold Alert... Operation Manual P0270 introduction Congratulations on your purchase of the P0270 Mold Alert! Mold is as old as the Earth and it s everywhere. Under the right set of conditions, it can actually
BEP FD-2 CONTOUR MATRIX FUME DETECTOR
BEP FD-2 CONTOUR MATRIX FUME DETECTOR INSTALLATION AND OPERATING INSTRUCTIONS Table of Contents 1 WARRANTY...3 2 IMPORTANT...3 3 CAUTIONS WHEN USING GAS SENSORS...3 4 FEATURES...4 5 SPECIFICATION...4 6
Instruction manual for Firstline FCS12000CH
Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of
Smoke Alarm User s Guide
10Y29 For model: 10Y29 Smoke Alarm User s Guide Lithium (non-replaceable sealed in) Battery-Operated Optical Smoke Alarm with HUSH TM Control to temporarily silence nuisance alarms. Thank you for purchasing
3 WATT LED SPOTLIGHT Model No. SLM - 3801
3 WATT LED SPOTLIGHT Model No. SLM - 3801 OWNER'S MANUAL Customer Service Tel: 1-800-268-3319 Superex Canada Ltd, Toronto,M2H 3B8 Made in China Table of Contents A). Important Safety Instructions B). Charging
Carbon monoxide. General information
Carbon monoxide General information Key Points Fire Flammable gas May react violently with other substances Use fine water spray with normal fire-fighting clothing and breathing apparatus Health Toxic
2-WAY WIRELESS SUPERVISED PHOTOELECTRIC SMOKE DETECTOR. Model: EL-4703 INSTALLATION INSTRUCTIONS
2-WAY WIRELESS SUPERVISED PHOTOELECTRIC SMOKE DETECTOR Model: EL-4703 INSTALLATION INSTRUCTIONS GENERAL DESCRIPTION Electronics Line's smoke detector is single station, photoelectric smoke detector with
Manual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
User s Guide. Security Systems D220
User s Guide Security Systems D220 Table of Contents About This User s Guide... 3 Introduction... 3 Security System Basics... 4 Controlled Points... 5 24-Hour Points... 6 Keypad Keys... 6 Keypad Lights...
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
Smoke Alarm User s Guide
P3010H Photoelectric Smoke Alarm w/ Safety Light P3010B Photoelectric Smoke Alarm w/ Voice Alarm P3010L Photoelectric Smoke Alarm Smoke Alarm User s Guide Thank you for purchasing this Kidde Smoke Alarm.
FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK
FIREPLACE HEATER FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK If you have any questions about the operation of your fireplace heater, please contact Crane Customer Care. Toll Free: 888-599-0992
Know Your Smoke Alarm
Know Your Smoke Alarm Updated January 29th 2008 Port Angeles Fire Department, Washington Ver. 1.0 Purpose of Smoke Alarms A smoke detector or smoke alarm is a device that detects smoke and issues an alarm
600-GD & 600-GDL 600 SERIES GAS DETECTOR
600-GD & 600-GDL 600 SERIES GAS DETECTOR INSTALLATION AND OPERATING INSTRUCTIONS This page has been deliberately left blank. Page 1 Table of Contents 1 WARRANTY...3 2 IMPORTANT...3 3 CAUTIONS WHEN USING
Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H
HR SERIES HEAT RECOVERY VENTILATOR (HRV) Home Owners Guide Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR100V HR160H & HR220H READ AND SAVE THIS GUIDE PP0924 09/2013 ABOUT S&P S&P is the world's
INSTRUCTION MANUAL PC5OO WITH PC5OORK KEYPAD
INSTRUCTION MANUAL PC5OO WITH PC5OORK KEYPAD TABLE OF CONTENTS SYSTEM INFORMATION 2 INTRODUCTION 3 Test Your System Regularly...3 Important Notice...3 Glossary...3 BASIC OPERATION 4 Arming Your System...4
ICC CODE CORNER 2012 IFC Code & Commentary
SECTION 908 EMERGENCY ALARM SYSTEMS 908.1 Group H occupancies. Emergency alarms for the detection and notification of an emergency condition in Group H occupancies shall be provided as required in Chapter
INSTRUCTION MANUAL PC255O
INSTRUCTION MANUAL PC255O Canadian Department of Communications Notice NOTICE: The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment
User Guide for the DS7060 Control/Communicator
DS7060 User Guide Copyright 1996-97 Detection Systems, Inc. User Guide for the DS7060 Control/Communicator Copyright 1996-97 Detection Systems, Inc. Detection Systems, Inc., 130 Perinton Parkway, Fairport,
Split Type Room Air Conditioner. KSWM units
OWNER S MANUAL Split Type Room Air Conditioner KSWM units Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.
WFS-627 User Manual. Wi-Safe Strobe Alert System Part of the Wi-Safe Home Safety System
WFS-627 User Manual Wi-Safe Strobe Alert System Part of the Wi-Safe Home Safety System INTRODUCTION 2 OVERVIEW 3 DEFINITIONS 4 APPLICATION 5 POSITIONING 5 LIMITATIONS 6 HOW TO INSTALL YOUR STROBE ALERT
SL280UHV SERIES GAS FURNACE WARNING
2010 Lennox Industries Inc. Dallas, Texas, USA 506677 01 11/2010 Supersedes 506409 01 SL280UHV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
616, 626, 636 & 646 Keypads
616, 626, 636 & 646 Keypads User s Manual TABLE OF CONTENTS 1.0 BASIC OPERATION...2 2.0 ACCESS CODES...4 3.0 ARMING & DISARMING...6 4.0 PANIC ZONES...13 5.0 KEY ACCESS PROGRAMMING.14 6.0 ADDITIONAL FEATURES...15
Ionization alarms are best suited for rooms, which contain highly combustible material. These types of material include:
Smoke Detector University Most people are aware of the danger of fire but are unaware of the fatality of smoke. More people die from breathing smoke than by burns. In fact, deaths from smoke inhalation
PC Tab Security System INSTRUCTION MANUAL
PC Tab Security System INSTRUCTION MANUAL This manual is intended as a Quick Start manual covering the basic functions that have been enabled on the alarm panel. The alarm panel is capable of extensive
Gas appliances. Get them checked Keep them safe. The problem
Gas appliances Get them checked Keep them safe The problem Every year about 14 people die from carbon monoxide poisoning caused by gas appliances and flues which have not been properly installed or maintained.
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
Fire Safety Risk Assessment Checklist for Residential Care Premises
Checklist for Residential Care Premises Name of Premises: Address of Premises: Name of Responsible Person: What area / location does the assessment cover? Does the assessment cover the whole site YES or
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
Combustible Gas Leak Detector 720b
Combustible Gas Leak Detector 720b The Value Leader TM Contents Specifications Product Features Standard Accessories Optional Accessories General Description Operating Instructions Battery Replacement
el-720 Carbon Dioxide Gas Leak Detector User s Guide
el-720 Carbon Dioxide Gas Leak Detector User s Guide Congratulations on the purchase of the AccuTools el-720 Carbon Dioxide Gas Leak Detector, the most technologically advanced instrument of its kind.
Fuels Safety Program FS- 072-06 7 DIRECTOR S PUBLIC SAFETY ORDER
Ref. No.: Rev. No.: Fuels Safety Program FS- 072-06 7 DIRECTOR S PUBLIC SAFETY ORDER Date: January 13, 2006 IN THE MATTER OF: THE TECHNICAL STANDARDS AND SAFETY ACT, 2000, S.O. 2000, c. 16 - and - ONTARIO
DUCT TYPE AIR CONDITIONER
OPERATING MANUAL OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES AIR CONDITIONER DUCT TYPE English Deutsch
User s Guide. Security Systems
User s Guide Security Systems National Security Systems Inc (800)457-1999 2 Table of Contents About This Users Guide... 4 Introduction... 4 Security System Basics... 5 Controlled Points... 6 24-Hour Points...
User s Guide. Security Systems
User s Guide Security Systems 2 Table of Contents About This Users Guide... 4 Introduction... 4 Security System Basics... 5 Controlled Points... 6 24-Hour Points... 7 Keypad Keys... 7 Keypad Tones... 8
User s Manual AURORA 1.2K/2.2K
User s Manual AURORA 1.2K/2.2K Uninterruptible Power System Safety CAUTION This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user serviceable
Conserve Socket Power Timer. User Guide
Conserve Socket Power Timer User Guide A device left plugged in but not in use can still draw power. The Conserve Socket Power Timer automatically shuts off power after the time interval you select so
Automatic Phone-Out Home Monitoring Systems
Automatic Phone-Out Home Monitoring Systems Power Outage and Freeze Alarm Model Number: THP202 Power Outage, Freeze and Flood Alarm Product Description Model Number: THP201 These monitoring systems are
FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM
FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM Page 0 Table of Contents Introduction 1 System Basics.. 1 Burglary Protection.. 1 Fire Protection.. 1 Security Codes. 1 Zones and Partitions
The client organisation that was best at meeting residents needs in the provision of a maintenance service
Wolverhampton Homes NHMF Best Practice Awards 2009 Submission for: - The client organisation that was best at meeting residents needs in the provision of a maintenance service Leaseholders gas maintenance
SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective
SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective The National Fire Alarm Code, NFPA 72, sets the minimum requirements of performance, selection, use and location of automatic detection
HILLS Series LED Code Pad User Manual
HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2
DIGITAL 7 YEAR LIFE CARBON MONOXIDE ALARM (Includes all colour variants)
CO-9D User Manual DIGITAL 7 YEAR LIFE CARBON MONOXIDE ALARM (Includes all colour variants) Please read me as I could save your life. Please retain this user manual for future reference CONTENTS INTRODUCTION
TWO BURNER PROPANE CAMPING STOVE
OWNER S MANUAL ASSEMBLY AND OPERATING INSTRUCTIONS TWO BURNER PROPANE CAMPING STOVE WARNING READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS IN THIS MANUAL TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE. Propane
DOMESTIC SMOKE ALARMS
SOUTH AUSTRALIAN METROPOLITAN FIRE SERVICE HOME FIRE SAFETY INFORMATION For further advice contact the Community Safety Department South Australian Metropolitan Fire Service on 8204 3611 DOMESTIC SMOKE
How To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
INSTRUCTION MANUAL LCD-6OO SECURITY STATION
INSTRUCTION MANUAL 1993 Digital Security Controls Ltd. 1645 Flint Road, Downsview, Ontario, Canada M3J 2J6 Printed in Canada 29000144 R1 LCD-6OO SECURITY STATION Table of Contents Introduction 1 About
White Paper. Best Practices for Gas Monitoring in the Commercial Kitchen
White Paper Best Practices for Gas Monitoring in the Commercial Kitchen Enhancing Kitchen Safety through Strategic Gas Monitoring Overview Commercial kitchens are one of the most hazardous commercial building
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
PAPER SHREDDER PRS-F-01 USER MANUAL
PAPER SHREDDER PRS-F-01 USER MANUAL INSTALLATION Only operate this product from the type of power source indicated on the marking label. If you are not sure of the type of power available, consult an
USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018
USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and
Indoor Air Quality. 2. Test and identify sources that contribute to poor indoor air quality.
Why is indoor air quality a concern? Safe air quality, both indoors and outdoors, is very important for health. In addition to poor outdoor air quality, indoor air quality is also a concern. Some examples
Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location
Wireless Alarm System Panic Button User s Manual Choice ALERT Control all sensors, accessories and remote transmitters from one location Table of Contents Important Safeguards 4 Introduction 5 Activating
527 CMR: BOARD OF FIRE PREVENTION REGULATIONS
527 CMR 31.00: CARBON MONOXIDE ALARMS Section 31.01: Purpose and Scope 31.02: Definitions 31.03: General Installation Provisions 31.04: Specific Installation Provisions 31.05: Carbon Monoxide Protection:
3000W Power Inverter
3000W Power Inverter OWNER S MANUAL Model number-4573000 TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND THIS INSTRUCTIONAL MANUAL. THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE
Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7
Register online today for a chance to win a FREE Tripp Lite product! www.tripplite.com/warranty Owner s Manual Internet Office & BC Personal UPS Systems Not suitable for mobile applications. Important
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...
TWO BURNER PROPANE CAMPING STOVE
842-A100-S_CmpStove.qxd 2/10/06 11:20 AM Page 1 OWNER S MANUAL TWO BURNER PROPANE CAMPING STOVE FAILURE TO FOLLOW ALL S AND INSTRUCTIONS IN THIS MANUAL COULD LEAD TO PERSONAL INJURY, INCLUDING DEATH. RETAIN
Upstate NY Recovery assistance information
Upstate NY Recovery assistance information www.nationalgrid.com Emergency contact information National Grid Customer Service 1-800-642-4272 National Grid Gas Emergency: 1-800-892-2345 Federal Emergency
Fire Damage. To Help Prevent. a Guide
a Guide To Help Prevent Fire Damage Fire damage in your home can be costly and emotionally devastating. The damage caused by the flames and smoke can destroy a lifetime of memories in a matter of minutes.
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
Installation Instructions
520 Installation Instructions Thank you very much for purchasing PIAA product. Please read this entire manual before installation and use of this product. For Installers Please give this Installation Manual
Dennis Fire Department Fire Prevention Mark Dellner Fire Chief
Dennis Fire Department Fire Prevention Mark Dellner Fire Chief FIRE SAFETY INSPECTION GUIDELINES FOR COMMERCIAL PROPERTIES (MA Fire Prevention Regulations 527 CMR, MGL Chapter 148) FIRE PREVENTION CHECKLIST-
IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.
THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to
Users Guide to Keypad Functions
Users Guide to Keypad Functions MANUAL NO. 700-175-01J ISSUED JAN 2002 VERSION 1.41 Summary of Operation A rm/ disarm [#] + [USER CODE] Quick Quick Quick Panic Fire Medical Away Arm Stay Arm Stay Arm &