The Pentacam: Precision, Confidence, Results, and Accurate Ks!
|
|
|
- Emma George
- 9 years ago
- Views:
Transcription
1 The Pentacam: Precision, Confidence, Results, and Accurate Ks! Produced under an unrestricted educational grant from Oculus, Inc. This monograph is based on an informational symposium presented at the 2006 AAO meeting in Las Vegas. The symposium informed attendees about the diagnostic capabilities of the Pentacam Comprehensive Eye Scanner as well as how best to integrate this pioneering instrument into clinical practice. MICHAEL W. BELIN, MD, FACS, MODERATOR JACK T. HOLLADAY, MD, MSEE, FACS MARC A. MICHELSON, MD J. TREVOR WOODHAMS, MD IQBAL IKE K. AHMED, MD, FRCSC BY MICHAEL W. BELIN, MD, FACS READING THE PENTACAM S MAPS Pattern recognition for screening patients for refractive surgery. Many surgeons who use the Pentacam Comprehensive Eye Scanner (Oculus, Inc., Lynnwood, WA) for the first time worry about misinterpreting the images and mistakenly including or excluding refractive surgery candidates. The key to successfully screening patients with the Pentacam is to create a standardized template that always displays the same maps in the same order using consistent colors and scales. Once you become familiar with the system, you should be able to recognize patterns that tell you if the patient s eyes are normal, usually in a matter of minutes, if not seconds. MY ROUTINE USE I use the Pentacam s four-picture composite report (Figure 1), which includes anterior elevation, posterior Figure 1. The Pentacam composite shows four maps at once. 16 I INSERT TO CATARACT & REFRACTIVE SURGERY TODAY I JANUARY 2007
2 A B Figure 3. Elevation points above the best-fit sphere are positive; numbers below the best-fit sphere are negative. Figure 2. The same eye imaged through two different references axes seems to show astigmatism (A) or keratoconus (B). elevation, pachymetry or corneal thickness, and sagittal curvature maps. I use the first three maps the most. I use best-fit sphere and float for the elevation map setting. My screening display for refractive surgery uses the ±75-µm elevation scale for all my refractive patients (I use a ±150-µm scale in my medical practice since I am evaluating pathology, not screening for normal patients). I use the color scale called intuitive, which I developed for Oculus, Inc., when I screen elevation and pachymetry maps. I limit my display so that it shows only the central 9-mm zone of the eye. Although the machine defaults to 12mm (it covers all the way out to the limbus), I find the central 9mm easier to look at clinically and for surgical screening. The placement of the different maps in the composite display does not matter, as long as it is consistent. CURVATURE MAPS NOT THE MOST INFORMATIVE I have been speaking about the limitations of curvature maps for more than 10 years, and I think surgeons tend to place too much emphasis on sagittal curvature. The curvature map, to a degree, reflects the anterior elevation, but it has many limitations that do not exist on the elevation map. Curvature is a reference-based measurement that changes with the angle of evaluation. These maps assume that the apex line of sight and the reference axis are the same, and they are not. Also, we incorrectly assume that people always look through the center of their corneas, and that the center of the cornea, the apex, and the pupillary center share the same location. If these points differ from one another, they can distort the sagittal curvature map and provide inaccurate clinical information. A Figure 4. Astigmatism has a flat axis that falls above the bestfit sphere and a steep axis that falls below it (A and B). In Figure 2, the curvature map on the left (A) seems to show a fairly normal astigmatic cornea, and the one of the right (B) seems to show a very suspicious-looking keratoconic eye. In actuality, these maps are of the same eye with different reference axes for curvature. Surgeons also tend to believe that the properties of the posterior corneal surface are less important than those of the anterior corneal surface. These two surfaces are equally important; in fact, the posterior corneal surface is probably more sensitive to pathology and more likely to show subtle changes earlier than the anterior surface. If you exclusively screen refractive patients based on their anterior corneal surfaces, you may miss important and potentially critical information. POSTERIOR ELEVATION MUST BE ACCURATE Accurate posterior elevation data are a requisite for accurate pachymetry, because pachymetry is simply the difference between the anterior and posterior surfaces. Because what we look at is not the real elevation data, we use an approach that allows us to pick up subtle changes. We compare the elevation to a shape, the most common being a best-fit sphere. We do not look at the actual elevation, but rather a representation to make it obvious that a shape has undergone change (Figure 3). UNDERSTANDING ECTATIC MAPS The Pentacam slide that probably is the most important B JANUARY 2007 I INSERT TO CATARACT & REFRACTIVE SURGERY TODAY I 17
3 Figure 5. Ectatic eyes often have islands of elevation above the best-fit sphere. Figure 5 shows another example of a normal anterior surface but an ectatic area. Look for islands of elevation above the best-fit sphere. In this eye, the curvature and anterior elevation look normal, but the pachymetric distribution is displaced inferiorly. The pachymetric distribution reflects that there is a very dramatic island on the posterior elevation. This is a map that should be very suspicious for early ectatic degeneration. In Figure 6, sagittal curvature has also been used to define the morphology of the cone in keratoconus. The limitation of curvature makes this parameter an unreliable indicator for locating the cone. Many refractive surgeons are reporting a high incidence of pellucid marginal degeneration (PMD) based on topographic curvature diagnosis. The vast majority of these cases are not true PMD, but reflect the limitation of trying to define shape while looking at a sagittal curvature map. These patients typically represent normal keratoconus with inferiorly displaced cones that get incorrectly located. In Figure 6, you can see that the anterior elevation, the posterior elevation, and the pachymetric distribution all place the cone at the inferior pupillary margin, while the curvature display incorrectly locates the cone near the limbus. CONCLUSION As newer technologies emerge, we can obtain a more comprehensive picture of the corneal anatomy. Accurate assessment of the posterior corneal surface and the pachymetric distribution adds significantly to our knowledge and should allow for better and more complete preoperative evaluations. Figure 6. Cone is often mistaken for pellucid marginal degeneration. and yet causes the most confusion is the comparison between elevation related to astigmatism and that which is abnormal secondary to an ectatic condition. Figure 4 shows an astigmatic map (A) and an ectatic map (B). How much elevation or depression exists in astigmatism does not matter, because by definition, astigmatism will have a flat axis that will fall above the best-fit sphere and a steep axis below this sphere. An astigmatic pattern may have µm in the flat axis and µm in the steep axis. The pachymetric map represents the thickness distribution throughout the cornea. It shows corneas that are not only thin, but with their thinnest portion significantly displaced. At times, the pachymetric distribution may be the most sensitive or earliest indicator of an ectatic disorder and may be abnormal in spite of a normal anterior corneal surface. Michael W. Belin, MD, FACS, is Professor and Director of Cornea & Refractive Surgery at Albany Medical College in New York and Medical Director of the TLC Laser Eye Center in Albany, New York. He serves as a consultant to Oculus, Inc. Dr. Belin may be reached at (518) JACK T. HOLLADAY, MD, MSEE, FACS USING THE HOLLADAY REPORT ON THE OCULUS PENTACAM Multiple mapping selections equal advanced preoperative detection. The Pentacam Comprehensive Eye Scanner differs fundamentally from the Orbscan (Bausch & Lomb, Rochester, NY) by the way in which it takes image slices of the cornea. The Orbscan takes vertical image slices that are separated from one another and have no common point. Thus, the Orbscan cannot re-register for 18 I INSERT TO CATARACT & REFRACTIVE SURGERY TODAY I JANUARY 2007
4 Figure 2. The density map shows lenticular opacities. Figure 1. The Pentacam takes multiple image samples. any eye movement that occurs while it is capturing the images. The Pentacam maintains the central point (the thinnest point) of each meridian in the sample images (Figure 1). Thus, during the examination, the software can re-register these central points and eliminate the eye movement. This single feature makes the Pentacam s measurements 10 times more accurate than the Orbscan s. The Pentacam s density maps allow the physician to quantitate opcacities. For example, the map of a cataract may show opacities that scatter light and degrade vision (Figure 2). Thus, the physician can show these maps to the patient and document the changes that are occurring to the patient s crystalline lens in his chart. CURVATURE MAPS I like to include curvature maps in my preoperative screening. It is true that curvature maps are relative to the center of the earth (primary corneal radius of curvature), and that height maps are relative to a vertex point on the cornea. The Pentacam uses a sagittal drop-down map to reference a fixed physical point on the surface of the cornea for elevation maps. When using a curvature map, you calculate a radius and then determine the major center of the radius of the curvature (a calculated point). If the machine does not calculate the right point, or if the patient is not lined up, then the radius-of-curvature calculation will be off. The Pentacam has an alignment device that prevents decentration. When performing IOL calculations, you cannot use height math to determine the power of the cornea. Corneal power is based on the height data; you must Figure 3. The Holladay Report displays five Pentacam maps. calculate a radius. Topography does not supply back surface power. Therefore, the variation in back surface power among the human population means that K readings that may appear the same between multiple patients are not exactly the same, because their posterior curvatures and net powers are different. In order to calculate posterior curvature values, my staff and I measured 100 consecutive refractive surgery patients who were between 20 and 30 years old with the Pentacam pre- and postoperatively. Using the historical method, we were able to calculate what their K readings should have been postoperatively. The correlation was 96%, with 0.55D standard deviation. Thus, we were able to predict patients postoperative refractive powers within 0.55D, which is much better than the historical and other methods. THE HOLLADAY REPORT Because I like to look at several maps when evaluating a patient, I worked with Oculus to create the JANUARY 2007 I INSERT TO CATARACT & REFRACTIVE SURGERY TODAY I 19
5 A B Figure 4. A best-fit sphere (A) does not align as well to a prolate cornea as a toric ellipsoid (B). A C Figure 5. Advanced preoperative detection with five maps: refractive power (A); tangential (B); sagittal anterior (C); relative pachymetry (D); and elevation [posterior] (E). Holladay Report (Figure 3). The Report uses a landscape rather than a portrait format to show a variety of information that can be printed out and placed in the chart for the physician. For example, I may want to know how the refractive power has changed over the surface of the cornea so I can correlate refractive changes with changes on the corneal surface. The refractive power map can identify whether cataract surgery has produced a decentered ablation zone. An axial power map would not show this information, but a refractive power map uses Snell s law and shows an index of refraction to calculate the power. The tangential map is also a curvature map, but is based on local radius of curvature; it is much more sensitive and detailed and therefore highlights any aberrations induced by refractive surgery. BEST-FIT SPHERES VERSUS ELLIPSOIDS Most physicians who transition from the Orbscan to the Pentacam are accustomed to using a best-fit sphere D B E (Figure 4A), because software written for these devices during the last 15 years was formulated for this shape. The profession is now moving toward using toric ellipsoids, which make the readings much more sensitive (Figure 4B). The technique is somewhat advanced; you no longer see a band across the corneal surface as you do in an eye with astigmatism when using sphere as a reference. Using toric ellipsoids, the Pentacam generates a new map called relative pachymetry. This system measures the front and back corneal powers and displays what we call an equivalent K reading over a 4-mm zone. Let me explain further. Every IOL formula used today reduces the K reading by 2% to compensate for the fact that the true net power of the cornea is approximately 0.75D (2%) less than the K reading. However, the Pentacam does measure true net power directly. If the true net power were input, with any of these formulas, they will reduce the calculated power by another 0.75D, thus producing 0.75D of error (double correction). The equivalent K reading boosts the IOL power s value to be comparable to the keratometer, but it also adjusts the calculation by the back surface power either positively or negatively to obtain the difference in the back power from the normal calculation that the keratometer assumes. For example, a measurement of 45.00D on the keratometer will measure 44.25D on the Pentacam s true net power. I change that to 45.00D so I have the same reading, but then I add or subtract the difference in the back surface power that was assumed by the keratometer. Most formulas assume the back surface of the cornea is 82.2% of the front surface power. If the reading is a little higher or lower, I can adjust the equivalent parametric power to utilize the precision of the Pentacam and take into account the back surface power, without needing a new A-constant for every lens available today to change it by 0.75D. This approach produces the right value for the calculation. 20 I INSERT TO CATARACT & REFRACTIVE SURGERY TODAY I JANUARY 2007
6 MAPPING CORNEAL ECTASIA Corneal ectasia by definition is a thinning keratoconus. The posterior surface usually reveals the first detectable thinning, because, as the epithelium gets thinner over the anterior surface of the cone, Bowman s membrane comes forward, making the thinning undetectable on curvature and height maps. I believe that a best-fit sphere is not as sensitive as the posterior surface map, because the cornea usually is prolate and has astigmatism. The back surface is never as precise as the front, because its curvature and height are calculated by looking through the front surface of the cornea, making the back surface a virtual image. The cornea is not a sphere, it is a football. A prolate ellipsoid shape only detects irregularities on a prolate surface. With this shape, an ectatic spot on a prolate cornea would look like a small bump on a map. Then, the tangential map, relative pachymetry map, and posterior elevation map all show the same hot spot point (Figure 5). A hot spot in the same location on all three maps indicates a suspicious irregularity such as a cone or corneal thinning. Thus, the information provided by these three maps equals advanced preoperative detection. The tangential map helps you look for the nipple of the aberration, the toric ellipsoid float helps you eliminate the normal elevation above the sphere so that you are looking only at the irregularity, and the relative pachymetry map directs you to the thinnest point on the cornea relative to its normal thickness. Jack T. Holladay, MD, MSEE, FACS, is Clinical Professor of Ophthalmology at Baylor College of Medicine in Houston, and he is Founder and Medical Director of the Holladay LASIK Institute in Bellaire, Texas. He is a consultant to Oculus, Inc. Dr. Holladay may be reached at (713) ; [email protected]. when analyzing the cornea for prospective refractive surgery. Corneal elevation is the measurement of height between two different points at different elevations. Elevation data is a primary data source for the Pentacam. Slope is the primary data source for Placido-disc based technology. The slope or the gradient is commonly used to describe the measurement of the steepness, incline, or grade of a straight line from two points with different elevations. A corneal topographer derives slope data from the reflection of concentric rings of light measuring the topography of the cornea. Figure 1. Nonorthogonal astigmatism on topography. MARC A. MICHELSON, MD CORNEAL ELEVATIONS, SLOPE, AND CURVATURE Why topography is not enough. The following two cases demonstrate why I find the Pentacam Comprehensive Eye Scanner so invaluable for screening and evaluating patients for refractive surgery. BACKGROUND Corneal elevation, slope, and curvature are three different measurements. Understanding their derivation and measurements becomes extremely important Figure 2. The Pentacam s sagittal curve front view. JANUARY 2007 I INSERT TO CATARACT & REFRACTIVE SURGERY TODAY I 21
7 Figure 3. This topographical map looks normal. Figure 4. The photokeratoscopic image of the same eye. Figure 5. The eye s front sagittal curve map. Slope is the first derivative of elevation. It is then used to calculate either elevation or curvature. Curvature is the rate of change of the slope. It is the second derivative of elevation and is calculated from slope data from the topography. Thus, looking at the source data, a topographer calculates the curvature and elevation from the slope, whereas the Pentacam uses elevation as its primary source data. This is an important distinction, because a topographer calculates (not measures) elevation data, and abnormal or surgically altered corneas may have multiple elevation solutions from these derived calculations. Since the Pentacam s primary data source is elevation, the first and second derivatives (slope and curvature) can be accurately calculated. CASE NO. 1 Figure 1 shows topography from a cornea that is obviously abnormal. This eye has nonorthogonal astigmatism. The Pentacam s sagittal curve front view Figure 6. The eye s preoperative anterior elevation map. (Figure 2) successfully mirrors the abnormal nonorthogonal corneal astigmatism as seen by topography, but the Pentacam provides much more information. Note the location of the cornea s thinnest point as well as the highest point of elevation. A posterior float of +21µm on the posterior elevation map indicates possible keratoconus. The Pentacam also has a keratoconic profile that provides indices of abnormal elevations and curvature confirming the abnormalities of this cornea. CASE NO. 2 Figure 3 is an axial topographical map of a cornea from a 33-year-old male with a refraction of X 10, yielding a BCVA of 20/25. The topography appears to be normal with a typical astigmatic pattern. Figure 4 shows the photokeratoscopic Placido-disc imagery of this cornea. I think is very important to review the photokeratoscope, because it is the primary source data for the topography. First, the central rings 22 I INSERT TO CATARACT & REFRACTIVE SURGERY TODAY I JANUARY 2007
8 are oval, thus indicating astigmatism. This clearly demonstrates an apical astigmatism of the cornea. This image also shows steep areas where the rings are compressed as well as flatter areas where they are more separated. The topographic map of this cornea does not have any steep or flat areas corresponding the steeper and flatter regions on the photokeratoscope. This information, standing alone and isolated, indicates that the patient may be a candidate for LASIK. The Pentacam, however, provides data that more closely resemble the photokeratoscope from the topographer than the axial topographic map. The system s sagittal curve front view reveals almost 6.80D of apical astigmatism at the center of his cornea. (Figure 5). There are steep areas that correspond to the contour map of the photokeratoscope of up to 50.20D, and corresponding flat areas of 46.00D: an almost a 4.00D differential within 0.50mm on the surface of the cornea. Thus, the topography accurately captured the source data from the photokeratoscopic map, but it failed to accurately compute this data to the axial topographic map, which in this case does not truly reflect the abnormalities of this cornea. Note the interesting elevation abnormalities of the front corneal surface on the anterior elevation map (Figure 6): there is a high point elevation of +12µm from a best-fit sphere and also a depression of -14µm. The back elevation data on this eye are not unusual, but the optical pachymetric map clearly shows an abnormal pachymetry by a decentered corneal apex at the thinnest part of the cornea. The Pentacam vividly shows that this patient is not a LASIK candidate. The astigmatism in the refraction does not match that in the cornea. There are 6.80D of central astigmatism at the corneal apex and the refraction was only 1.75D of astigmatism. The kertaoconic profile states that the cornea is abnormal. The K-values on the Pentacam exceed 48.00D. The Pentacam has successfully identified an abnormal cornea, when, in fact, the topography clearly did not. This case clearly has medicolegal implications. If a preoperative Pentacam analysis on this patient s eye reads abnormal, then the physician should not proceed with surgery. Marc A. Michelson, MD, is Clinical Associate Professor of Ophthalmology at the UAB Medical Center in Birmingham, Alabama, and he practices Ophthalmology at the Alabama Eye & Cataract Center, P.C., in Birmingham. He has received honoraria and reimbursement for travel for speaking on behalf of Oculus. Dr. Michelson may be reached at (205) ; [email protected]. J. TREVOR WOODHAMS, MD PENTACAM FOR THE REFRACTIVE IOL SURGEON This technology is not limited to LASIK surgeons. Over the past year, the number of lens-based refractive procedures I performed in my practice increased dramatically, whereas I used to offer cornea-based refractive surgery exclusively. This change presented my staff and I with new challenges, such as selecting candidates for LASIK. When we screen for contraindicative pathologies like keratoconus and forme fruste keratoconus, the corneal and elevation topography available on the Pentacam Comprehensive Eye Scanner are much better than Placido-based topography, especially with the new software developed by Jack Holladay, MD. Thus, the Pentacam takes the guesswork out of patient selection. Figure 1. Pathologies identified with the Pentacam. Figure 2. Is this a cataract? The Pentacam tracks progression. JANUARY 2007 I INSERT TO CATARACT & REFRACTIVE SURGERY TODAY I 23
9 Figure 3. Scheimpflug imaging of an incorrectly sized ICL. CLINICAL USE I have been using the Pentacam for about 3 years. For lenticular surgery, I use it to calculate (1) the lens thickness for the Holladay II IOL formula, (2) the anterior chamber depth for primary IOL formulas, (3) the space between the back of the cornea and the anterior lens capsule, and (4) the distance from the anterior chamber to the IOL for piggybacking. My staff and I also use the device to look for eccentric apices, corresponding float areas, and borderline abnormal corneal thicknesses (Figure 1). This technology evaluates the cornea for surgery more consistently than the Orbscan topographer (Bausch & Lomb, Rochester, NY). It also provides more information about the anterior chamber, which I believe is refractive surgery s new frontier. IMAGING BEHIND THE CORNEA The Pentacam uses a bright flash (Scheimpflug photography) to take images of the exposed anterior chamber. When used through a dilated pupil, it provides the anterior chamber s depth, density, thickness, diameter, and angle measurement. These data are important because IOL implantation nomograms are still evolving. Surgeons no longer believe that white-to-white distance is an accurate measurement of the ciliary sulcus diameter, which is an important parameter for implanting implantable contact lenses (Visian ICL; STAAR Surgical Company, Monrovia, CA) in particular. OTHER CLINICAL APPLICATIONS Documenting and Following Pathology The Pentacam can help the surgeon document lenticular changes in questionable eyes and track them over time. For example, does the eye in Figure 2 have a cataract? It is my eye, with 20/20 vision and modest night vision complaints. The Pentacam can track the opalescence as it develops. Figure 4. The tilt of an implanted accommodative IOL. Determining Room for an ICL When implanting an ICL, the surgeon must determine whether the eye s angle is wide enough or deep enough for the lens to push the iris forward. Figure 3 shows a patient with too long an ICL because of poor white-to-white calculations. Note the grossly excessive vault. Revealing IOL Tilt Figure 4 shows an eye implanted with a Crystalens Accommodating IOL (Eyeonics, Inc., Aliso Viejo, CA) approximately 4 years ago, when these lenses were experiencing some problems with Z syndrome. The image shows intact anterior and posterior capsules and the tilted IOL. Accommodative IOL Placement I anticipate that refractive lens surgeons will find the Pentacam important for managing the capsule and selecting designs of future accommodative IOLs. We will have to know the thickness of these lenses and the depth of the posterior chamber. The Pentacam can measure true white-to-white diameters. Moreover, researchers are conducting biometric studies in order to produce an MRI of the eyeball and ensure the best fit for ICLs. Anterior Chamber Measurements for IOL Exchange Many of my patients who underwent RK 10 years ago are now requesting enhancements, and I often implant the Crystalens. Unfortunately, these patients frequently need an IOL exchange due to power calculation difficulties. The Pentacam can get the most accurate measurement from either the anterior or posterior surface to the front of the IOL once the natural lens is removed. SUMMARY In conclusion, the Pentacam s diagnostic utility is not limited to LASIK, but will also be crucial for refractive lens 24 I INSERT TO CATARACT & REFRACTIVE SURGERY TODAY I JANUARY 2007
10 procedures. The system s ability to visualize and measure the anterior segment s structures is currently unsurpassed. I look forward to the added level of accuracy that the new high-definition model will bring to this technology. J. Trevor Woodhams, MD, is Surgical Director of the Woodhams Eye Clinic in Atlanta. He acknowledged no financial interest in the products or companies mentioned herein but is reimbursed for travel expenses by Oculus, Inc. Dr. Woodhams may be reached at (770) ; [email protected]. IQBAL IKE K. AHMED, MD, FRCSC PENTACAM: WHAT EVERY CATARACT SURGEON NEEDS TO KNOW (And benefit from.) The advantages the Pentacam Comprehensive Eye Scanner brings to the corneal refractive surgeon are quite apparent. My colleagues and I have been using the device for more than 18 months, during which I have identified six important ways the Pentacam serves cataract surgeons. N O. 1: ASTIGMATIC CORRECTION We have used the Pentacam s corneal topographic and thickness maps when performing limbal relaxing incisions (LRIs) or astigmatic keratotomy either intra- or postoperatively to correct astigmatism. With the current drive toward refractive precision and spectacle independence, most users now are attempting or at least considering utilizing the device s adjunctive corneal incisional treatment for cylinder as well. The system is also very helpful in identifying patients who may have irregular astigmatism. Surgeons must look for asymmetric versus symmetric cylinder and determining the appropriate incisional location and depth. Figure 1. This eye had 4.10D of cylinder preoperatively. Figure 1 shows a typical example of an eye that presents with a cataract and has a significant amount of astigmatic corneal cylinder. After receiving LRIs along the axis of the positive cylinder, the eye looks significantly different in the curvature maps, and its astigmatism has been reduced to around 1.50D (Figure 2). In this case, the Pentacam added value by providing curvature maps as well as corneal thickness measurements so that the surgeon could adjust the depth of the incisions. Measurements of the corneal periphery can also aid in determining the appropriate location and depth of those incisions. Many surgeons are now using LRIs postoperatively at the slit lamp as refractive touch-ups. Safety is extremely important in this application, and here again the Pentacam s corneal thickness measurements can be useful. N O. 2: COMBINING PENTACAM DATA WITH WAVEFRONT ANALYSIS How can we combine wavefront analysis of corneal spherical aberrations, higher-order aberrations, and spherical aberration-correcting IOLs with the measurements the Pentacam delivers? The Pentacam provides a Zernike analysis of the cornea, which is something I think will be of great value for determining the appropriate customized IOL for specific patients. Postoperative refractive targets in cases of spherical aberration is still a matter for debate: do we target zero, or else a little bit of positive spherical aberration to try to optimize the patient s contrast sensitivity? With the current Pentacam platform, this corneal spherical aberration measurement is given as a coefficient of the Zernike polynomial the system calculates. It does require third-party software to determine the desired postoperative result. N O. 3: CATARACT ASSESSMENT: DENSITY, CONSISTENCY, AND THICKNESS The Pentacam is able to evaluate a cataract s location, density, thickness, and consistency as well as the anterior chamber s depth, width, and angle measurements (Figure 3). Ophthalmic surgeons proceeding into intraocular and cataract surgery will increasingly rely on appropriate three-dimensional assessments of the eye for surgical planning. I foresee a time when we enter cataract density measurements into a phaco machine to determine a patient s appropriate power modulation and fluidics. The device can also assess more subtle phenomena, like posterior capsular opacification and an anterior cortical or anterior subcapsular cataract. NO. 4: AC DEPTH AND ANGLE MEASUREMENTS Knowing anterior chamber dimensions are also useful for treating ocular pathologies. For example, pseudoexfoliation patients can have a shallow chamber (as narrow as 2.5mm) that increases their risk of intraoperative complications. This JANUARY 2007 I INSERT TO CATARACT & REFRACTIVE SURGERY TODAY I 25
11 Figure 2. The eye s astigmatic cylinder was reduced to 1.50D. Figure 3. Different grades of cataract seen with the Pentacam. Figure 4. The post-lasik Holladay Report for keratometry. feature of the Pentacam can also be useful for determining angle closure and sizing anterior chamber IOLs. The system allows the surgeon to examine angle-to-angle measurements and trabecular-iris angle measurements (for patients who may be at risk for angle closure) and reconstruct a three-dimensional model of the anterior chamber. N O. 5: PERFORMING KERATOMETRY IN THE POST-LASIK PATIENT The Holladay II report is essential for determining keratometry for patients who have had LASIK or corneal refractive surgery (Figure 4). Because the Pentacam enables central corneal sampling compared to Placido-disc technology and also is able to determine anterior and posterior corneal curvature and thus ratio, Dr. Holladay has devised calculations to provide more accurate keratometry for IOL calculations in the post-lasik patient. N O. 6: IOL ASSESSMENT The ability to postoperatively view and evaluate IOL positioning, centration, and tilt is invaluable, especially Figure 5. The Pentacam calculates best-fit curve and plane. when a patient has not achieved the desired result or may have postoperative dysphotopsia or other visual complaints. Certain third-party software for the Pentacam can easily illustrate the outline of an IOL in most cases. It can then calculate a lens best-fit curve and plane in comparison to the optical and geometric axes of the anterior chamber, thus allowing the physician to determine the correct positioning of the IOL (Figure 5). SUMMARY I have found that the Pentacam offers significant value to the cataract surgeon as ophthalmology evolves into an era where imaging is becoming more important in all areas of the eye. Iqbal Ike K. Ahmed, MD, FRCSC, is Assistant Professor at the University of Toronto and Clinical Assistant Professor at the University of Utah in Salt Lake City. He is not a consultant to Oculus, Inc., and he acknowledged no financial interest in the company or its products. Dr. Ahmed may be reached at (905) ; [email protected]. 26 I INSERT TO CATARACT & REFRACTIVE SURGERY TODAY I JANUARY 2007
Keratoconus Detection Using Corneal Topography
Keratoconus Detection Using Corneal Topography Jack T. Holladay, MD, MSEE, FACS ABSTRACT PURPOSE: To review the topographic patterns associated with keratoconus suspects and provide criteria for keratoconus
The Pentacam: Offering a Clearer View
Supplement to Sponsored by an educational grant from Oculus, Inc. February 2008 The Pentacam: Offering a Clearer View Densitometry software for cataracts Topography for premium-channel cataract surgery
Incision along Steep Axis
Toric IOL An option or a must? ~ 15% cataract surgical patients >1.5 D Options: spectacles, CLs, Incision along steep axis, LRI, AK, toric IOL, Excimer Laser or a combination Walter J. Stark, MD Professor
What is the main target for all phaco surgeons?
CORRECTION C O OF ASTIGMATISM DURING CATARACT SURGERY Abdallah dllh K. Hassouna, M.D. Sherein S. Wahba, M.D. Ain Shams University 2009 Main target What is the main target for all phaco surgeons? Main Target
OCULUS PENTACAM BASIC CLASSIC HR
OCULUS PENTACAM BASIC CLASSIC We focus on progress Many Patients have Apprehensions before an Examination. > The eye is an extremely sensitive area Loss or impairment of sight always produces anxiety.
How do we use the Galilei for cataract and refractive surgery?
How do we use the Galilei for cataract and refractive surgery? Douglas D. Koch, MD Mariko Shirayama, MD* Li Wang, MD, PhD* Mitchell P. Weikert, MD Cullen Eye Institute Baylor College of Medicine Houston,
Pentacam. The. The gold standard in anterior segment tomography. Supplement to February 2011
Supplement to February 2011 The Pentacam The gold standard in anterior segment tomography. Produced under an educational grant from Oculus Optikgeraete GmbH. THE PENTACAM The Pentacam: An Impressive Technology
MAke A difference in someone s life
MAke A difference in someone s life Fitting guide En del av Multilens contents Introduction 1 Applications 2 characteristics 2 Fitting philosophy 3 Fitting process 4 Ideal fit 5 Comfort vs lens awarness
Page: 1 of 6. Corneal Topography/Computer-Assisted Corneal Topography/ Photokeratoscopy
Section: Surgery Effective Date: July 15, 2015 Last Review Status/Date: June 2015 Page: 1 of 6 Corneal Topography/ Photokeratoscopy Description Computer-assisted topography/photokeratoscopy provides a
Ectasia after laser in-situ keratomileusis (LASIK)
Ectasia after laser in-situ keratomileusis (LASIK) 長 庚 紀 念 醫 院 眼 科 蕭 靜 熹 Post-LASIK ectasia A rare complication of LASIK Manhattan jury awarded a former investment banker a record $7.25 million for post-lasik
5/24/2013 ESOIRS 2013. Moderator: Alaa Ghaith, MD. Faculty: Ahmed El Masri, MD Mohamed Shafik, MD Mohamed El Kateb, MD
ESOIRS 2013 Moderator: Alaa Ghaith, MD Faculty: Ahmed El Masri, MD Mohamed Shafik, MD Mohamed El Kateb, MD 1 A systematic approach to the management of Keratoconus through the presentation of different
CORNEAL TOPOGRAPHY. Refractive power of the eye
CORNEAL TOPOGRAPHY Anne Faucher, M.D., FRCS University of Toronto Refractive power of the eye Eye has 3 refractive elements: 1. Cornea 2. Lens 3. Axial length Cornea (air/tear film interface) provides
THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening
THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening GALILEI G4 Clinical Applications Corneal Implant Planning The comes with a licensable corneal inlay software
PRACTITIONER S FITTING GUIDE. Keratoconus Irregular Cornea Post Graft
PRACTITIONER S FITTING GUIDE Keratoconus Irregular Cornea Post Graft Four lens designs to fit all corneal shapes... One simple systematic approach to fitting Featuring Easy-to-fit using a simple systematic
OCULUS Pentacam Pentacam HR
OCULUS Pentacam Pentacam HR The Gold Standard in Anterior Segment Tomography We focus on progress Providing the best care to your patients > The eye is extremely sensitive. Loss or impairment of sight
How To Implant A Keraring
Corneal Remodeling Using the Keraring A variety of thicknesses, arc lengths, and optical zone sizes allows tailoring of the procedure to the individual patient. BY DOMINIQUE PIETRINI, MD; AND TONY GUEDJ
Management of Astigmatism in Cataract Surgery
Management of Astigmatism in Cataract Surgery Jonathan B. Rubenstein, M Vice- Chairman and eutsch Family Professor of Ophthalmology irector of Refractive Surgery Rush University Medical Center Financial
ALL-IN-ONE Optical Biometry, Dual Scheimpflug Tomography and Placido Topography
ALL-IN-ONE Optical Biometry, Dual Scheimpflug Tomography and Placido Topography GALILEI G6 Clinical Applications High confidence premium IOL selection The GALILEI G6 offers a link to the ray-tracing software
IOL Power Calculation After Myopic LASIK. Hany Helaly, Lecturer of Ophthalmology, Faculty of Medicine, Alexandria University.
IOL Power Calculation After Myopic LASIK Hany Helaly, Lecturer of Ophthalmology, Faculty of Medicine, Alexandria University. SUPERVISORS Prof. Dr. Mohammad El-Hifnawy Professor of Ophthalmology Faculty
Insert to October 2014. Sponsored by OCULUS Optikgeräte GmbH EXPERT STRATEGIES FOR YOUR DAILY PRACTICE. Pentacam Take a closer look.
Insert to October 2014 Sponsored by OCULUS Optikgeräte GmbH EXPERT STRATEGIES FOR YOUR DAILY PRACTICE Pentacam Take a closer look. Contents Improving Quality of Vision After Cataract Surgery... 3 BY H.
Course # Intra Corneal Ring Segments Contact Lens Management of Irregular Astigmatism
Course # 772 Intra Corneal Ring Segments Contact Lens Management of Irregular Astigmatism Intra Corneal Ring Segments Contact Lens Management of Irregular Astigmatism Financial Disclosure I do not own
Insert to October 2013 THE COMPLETE PICTURE. Experiences with the ALADDIN system. Sponsored by Topcon
Insert to October 2013 THE COMPLETE PICTURE Experiences with the ALADDIN system Sponsored by Topcon THE COMPLETE PICTURE Advantages of The Aladdin How this all-in-one optical biometer edged out the IOLMaster
AcrySof IQ Toric IOL (SN6ATT) Surgeon Keys for Success & Acknowledgement
AcrySof IQ Toric IOL (SN6ATT) Surgeon Keys for Success & Acknowledgement Alcon Laboratories, Inc is pleased to announce the availability of the AcrySof IQ Toric intraocular lens, and delighted that you
Curtin G. Kelley, M.D. Director of Vision Correction Surgery Arena Eye Surgeons Associate Clinical Professor of Ophthalmology The Ohio State
Curtin G. Kelley, M.D. Director of Vision Correction Surgery Arena Eye Surgeons Associate Clinical Professor of Ophthalmology The Ohio State University Columbus, Ohio Refractive Errors Myopia (nearsightedness)
EUROPEAN JOURNAL OF PHARMACEUTICAL AND MEDICAL RESEARCH www.ejpmr.com
ejpmr, 2015,2(3), 436-440 EUROPEAN JOURNAL OF PHARMACEUTICAL AND MEDICAL RESEARCH www.ejpmr.com Tumram et al. SJIF Impact Factor 2.026 Research Article ISSN 3294-3211 EJPMR CLINICAL OUTCOME OF TORIC IOL
Refractive Surgery. Common Refractive Errors
Refractive Surgery Over the last 25 years developments in medical technology and Refractive Surgery allow almost all need for glasses and contact lenses to be eliminated. Currently there are a number of
Kerry D. Solomon, MD, is Director of the Carolina Eyecare Research Institute at Carolina Eyecare Physicians in Charleston, S.C.
I think the ideal diagnostic technology for all of us would be a device where we could take a measurement, make an adjustment based on the patient s history, including past surgery, and come up with an
Minimally Invasive Surgery: Femtosecond Lasers and Other Innovative Microsurgical Techniques
Minimally Invasive Surgery: Femtosecond Lasers and Other Innovative Microsurgical Techniques Julio Narváez MD Associate Professor of Ophthalmology Loma Linda University Non-Refractive Applications of Femtosecond
What are your options for correcting astigmatism?
What are your options for correcting astigmatism? If you depend upon eyeglasses, you may have experienced the inconvenience of not being able to find your glasses when you really need them. Eyeglasses
Surgical Advances in Keratoconus. Keratoconus. Innovations in Ophthalmology. New Surgical Advances. Diagnosis of Keratoconus. Scheimpflug imaging
Surgical Advances in Keratoconus Keratoconus Ectatic disorder 1 in 1,000 individuals Starts in adolescence & early adulthood Uncertain cause 20% require corneal transplant Innovations in Ophthalmology
Customized corneal ablation and super vision. Customized Corneal Ablation and Super Vision
Customized Corneal Ablation and Super Vision Scott M. MacRae, MD; James Schwiegerling, PhD; Robert Snyder, MD, PhD ABSTRACT PURPOSE: To review the early development of new technologies that are becoming
KERATOCONUS IS A BILATERAL, ASYMMETRIC, CHRONIC,
Comparison of and Intacs for Keratoconus and Post-LASIK Ectasia MUNISH SHARMA, MD, AND BRIAN S. BOXER WACHLER, MD PURPOSE: To evaluate the efficacy of single-segment Intacs and compare with double-segment
7/24/2014 ORBSCAN. Dr. HARITHA
ORBSCAN Dr. HARITHA Cornea is the most powerful refractive element, contributing 43D of total 60D power of eye. Anterior surface elliptical, HD-11.5mm VD-10.6mm. Posterior surface- circular,avg D- 11.5mm
Refractive Surgery. Evolution of Refractive Error Correction
Refractive Surgery Techniques that correct for refractive error in the eye have undergone dramatic evolution. The cornea is the easiest place to place a correction, so most techniques have focused on modifying
Cataract Testing. What a Patient undergoes prior to surgery
Cataract Testing What a Patient undergoes prior to surgery FINANCIAL DISCLOSURE I have no financial interest or relationships to disclose What do most Technicians find to be the most mundane yet very important
Make a difference in someone s life FITTING GUIDE
Make a difference in someone s life FITTING GUIDE CONTENTS Introduction 3 Applications 4 Characteristics 4 Fitting philosophy 5 Mid-peripheral / limbal zone 6 Only 3 fitting variables to determine 7 Ideal
SCHWIND CAM Perfect Planning wide range of applications
SCHWIND CAM Perfect Planning wide range of applications ORK-CAM PresbyMAX PALK-CAM PTK-CAM 2 SCHWIND CAM the system solution The latest version of the modular SCHWIND CAM represents an even more efficient
LASIK. Complications. Customized Ablations. Photorefractive Keratectomy. Femtosecond Keratome for LASIK. Cornea Resculpted
Refractive Surgery: Which Procedure for Which Patient? David R. Hardten, M.D. Minneapolis, Minnesota Have done research, consulting, or speaking for: Alcon, Allergan, AMO, Bausch & Lomb, Inspire, Medtronic,
Looking for Keratoconus
07.31.06 Screening for LASIK: Tips and Techniques Surgeons share helpful strategies for identifying which patients are good candidates and which could be trouble. Christopher Kent, Senior Editor Screening
IOL Power Calculations for Postrefractive Surgery Eyes
eyetube.net The Creator s Forum: IOL Power Calculations for Postrefractive Surgery Eyes Olsen Formula By Thomas Olsen, MD, PhD The calculation of IOL power in an eye that has undergone corneal refractive
Insert to. January 2011. Comfort and confidence for all IOL calculations
Insert to January 2011 Comfort and confidence for all IOL calculations Advanced Optical Biometry and Keratometry with LENSTAR LS 900 CONTENTS Lenstar and Ray-Tracing Calculations...3 By Jaime Aramberri,
Irregular astigmatism:
Irregular astigmatism: definition, classification, topographic and clinical presentation Ming X. Wang, MD, PhD Clinical Associate Professor of Ophthalmology of University of Tennessee Director, Wang Vision
Cataract Surgery in Small Eyes Richard S. Hoffman, MD Clinical Associate Professor of Ophthalmology Oregon Health & Science University No Financial Interests Anatomic Classification Short AC depth with
Cataract Surgery after Myopic Refractive Procedures. Ray Guard Eye Center Huang Wei-Jen, MD
Cataract Surgery after Myopic Refractive Procedures Ray Guard Eye Center Huang Wei-Jen, MD Financial Disclosures : * No financial interest on products mentioned Cataract Surgery after Myopic Refractive
Post LASIK Ectasia. Examination: Gina M. Rogers, MD and Kenneth M. Goins, MD
Post LASIK Ectasia Gina M. Rogers, MD and Kenneth M. Goins, MD October 6, 2012 Chief Complaint: Decreasing vision after laser- assisted in- situ keratomileusis (LASIK) History of Present Illness: This
415.922.9500 www.pacificvision.org
Issue 046 September 2012 efocus Excellence in Co-Managed Care P A C I F I C V I S I O N I N S T I T U T E Life in Focus 415.922.9500 www.pacificvision.org Last month, we held a dinner with the Bay Area
Consumer s Guide to LASIK
Consumer s Guide to LASIK A Community Service Project brought to you by Price Vision Group Your Guide To A Successful LASIK Procedure The purpose of this educational guide is to help prospective patients
final corrected draft
Archived at the Flinders Academic Commons http://dspace.flinders.edu.au/dspace/ This is the author s final corrected draft of this article. It has undergone peer review. Citation for the publisher s version:
Providing Optimal Optics For Your Astigmatic Cataract Patients. While the cornea remains relatively stable and prolate throughout life
Providing Optimal Optics For Your Astigmatic Cataract Patients David I. Geffen, OD, FAAO Why keep the crystalline lens? While the cornea remains relatively stable and prolate throughout life Unless we
Optimizing outcomes with toric IOLs
digital.eyeworld.org The news magazine of the American Society of Cataract & Refractive Surgery Optimizing outcomes with toric IOLs Supplement to EyeWorld May 2015 Supported by an educational grant from
Alexandria s Guide to LASIK
Alexandria s Guide to LASIK A Community Service Project sponsored by: Wallace Laser Center Your Guide To A Successful LASIK Procedure The word LASIK is actually an acronym for Laser Assisted In-Situ Keratomileusis.
Phacoemulsification: Considerations for Astigmatism Management Jason P. Brinton, MD and Thomas A. Oetting, MS, MD June 10, 2011
Phacoemulsification: Considerations for Astigmatism Management Jason P. Brinton, MD and Thomas A. Oetting, MS, MD June 10, 2011 Introduction Patient expectations for cataract surgery have increased significantly
Supplement to October 2014. Master Your Toric Planning and Improve Refractive Outcomes With the LENSTAR LS 900. Sponsored by
Supplement to October 2014 Master Your Toric Planning and Improve Refractive Outcomes With the LENSTAR LS 900 Sponsored by Contents Lenstar and the T-Cone Toric Platform... xx Offering sophisticated planning
Paragon RG-4 Fitting Reference Guide
PARAGON VISION SCIENCES Paragon RG-4 Fitting Reference Guide* & Certification Manual 2008 *This document is an abbreviated version and does not replace the FDA approved professional fitting guide. Lenses
ADVANCED IOL POWER CALCULATIONS. Jack T. Holladay, MD, MSEE, FACS
Jack T. Holladay, M.D., M.S.E.E., F.A.C.S. ADVANCED IOL POWER CALCULATIONS Jack T. Holladay, MD, MSEE, FACS I. Formulas and Measurements A. Variables Used to Predict ACD 1. Binkhorst 2-1981 - AL 2. Holladay
COS Statement on Values for Uninsured Services in Canada
COS Statement on Values for Uninsured Services in Canada Introduction A number of eye health services provided by physicians are not considered medically necessary and are therefore not insured under provincial
ADVANCED IOL POWER CALCULATIONS. Jack T. Holladay, MD, MSEE, FACS
Jack T. Holladay, M.D., M.S.E.E., F.A.C.S. ADVANCED IOL POWER CALCULATIONS Jack T. Holladay, MD, MSEE, FACS I. Formulas and Measurements A. Variables Used to Predict ACD 1. Binkhorst 2-1981 - AL 2. Holladay
Comparison to other anterior segment imaging devices
found helpful in a number of areas of ophthalmology. However, in the field of anterior segment tumors its usefulness is confined to a subset of tumors that are confined to the iris, hypo pigmented, and
ICRS implantation with the Femto LDV laser in stabilized KC patients: 6 months results
ICRS implantation with the Femto LDV laser in stabilized KC patients: 6 months results Jérôme C. VRYGHEM, M.D. Brussels Eye Doctors Brussels, Belgium No financial interest! A lot of KC patients show interest
Premium Lenses in Problematic Patients
Premium Lenses in Problematic Patients How to be successful with presbyopic lenses in eyes that have already had LASIK surgery. Walter Bethke, Managing Editor If implanting a monofocal intraocular lens
The Galilei Dual Scheimpflug Analyzer incorporates multiple diagnostic modalities into one device to map the cornea and anterior segment.
Supplement to March 2009 The Galilei Dual Scheimpflug Analyzer incorporates multiple diagnostic modalities into one device to map the cornea and anterior segment. Sponsored by an unrestricted educational
Making the Most of High-tech Biometry
4/2/2014 Making the Most of High-tech Biometry Today s advanced technology calls for a well-informed user in order to optimize results. Here s help. By Christopher Kent Senior Editor As cataract surgery
Welcome to the Verisyse Seminar
Patient Seminar Welcome to the Verisyse Seminar Today we ll answer some of the most common questions about the Verisyse Phakic Intraocular Lens (IOL) including: Who is a candidate How the procedure is
ABrand New Refraction Meas urement Instrument
PW ABrand New Refraction Meas urement Instrument The TOPCON KR-9000PW WAVEFRONT ANALYZER incorporates comprehensive measurement of the eye's total optical system which has not been achieved until now,
Simple regression formula for intraocular lens power adjustment in eyes requiring cataract surgery after excimer laser photoablation
J CATARACT REFRACT SURG - VOL 32, MARCH 26 Simple regression formula for intraocular lens power adjustment in eyes requiring cataract surgery after excimer laser photoablation Samuel Masket, MD, Seth Everett
Posterior Corneal Astigmatism: Is It Important? MP Weikert, MD Baylor College of Medicine October 23, 2011
: Is It Important? MP Weikert, MD Baylor College of Medicine October 23, 2011 Corneal Imaging What major challenge do we face when imaging the cornea? Measuring the curvature & refractive power of the
Standardized Analyses of Correction of Astigmatism With the Visian Toric Phakic Implantable Collamer Lens
Standardized Analyses of Correction of Astigmatism With the Visian Toric Phakic Implantable Collamer Lens Donald R. Sanders, MD, PhD; Edwin J. Sarver, PhD ABSTRACT PURPOSE: To demonstrate the methodology
Supplement to January 2013. Sponsored by STAAR Surgical. New Outcomes:
Supplement to January 2013 Sponsored by STAAR Surgical New Outcomes: Visian ICL CentraFLOW Technology Highlights from the Ninth Annual Visian ICL Experts Symposium, September 2012 Visian ICL With KS-Aquaport
Cornea and Refractive Surgery Update
Cornea and Refractive Surgery Update Fall 2015 Optometric Education Dinner Sebastian Lesniak MD Matossian Eye Associates Disclosures: None Bio: Anterior Segment and Cornea Surgery Fellowship Wills Eye
AVOIDING VISUAL COMPLAINTS WITH PREMIUM IOLS Total corneal power must be evaluated to achieve success with multifocal and toric IOLs.
Supplement to October 2013 ALL-IN-ONE The most complete solution for refractive and cataract surgery. CONTENTS TECHNOLOGICAL ADVANCES OF THE GALILEI All you need for daily clinical practice, in one device.
Richard S. Hoffman, MD. Clinical Associate Professor of Ophthalmology Oregon Health & Science University
Zeiss Mel 80 and Visumax Refractive Laser Systems Richard S. Hoffman, MD Clinical Associate Professor of Ophthalmology Oregon Health & Science University No Financial Interest ZEISS Workstation CRS-Master
Timothy D. McGarity, M.D.
Timothy D. McGarity, M.D. Dr. McGarity received his B.S. in Microbiology, honors, at the University of Arkansas, Fayetteville, and his M.D. at the University of Arkansas for Medical Sciences, Little Rock.
VA high quality, complications low with phakic IOL
Page 1 of 5 VA high quality, complications low with phakic IOL Use in keratoconus will continue, one surgeon predicts; another ponders long-term safety Nov 1, 2007 By:Nancy Groves Ophthalmology Times Several
Overview. Addressing Astigmatism with Toric IOL Implantation: Pre-Operative and Operative Considerations. Where are we now? How have we progressed?
Addressing Astigmatism with Toric IOL Implantation: Pre-Operative and Operative Considerations Jason Wang, M.D. Spring Symposium 2012 OMNI Eye Specialists / Spivack Vision Center March 3, 2012 Overview
When To Laser, When To Implant, When To Do Both
When To Laser, When To Implant, When To Do Both Scott MacRae, MD Professor of Ophthalmology Professor of Visual Sciences StrongVision Refractive Surgery Center University of Rochester Eye Institute Refractive
OMNI EYE SPECIALISTS. The Intraocular Lens
OMNI EYE SPECIALISTS Intraocular Lens Options In Cataract Surgery Or Refractive Lens Exchange Surgery Your decision to have vision surgery is important and the doctors at Omni Eye Specialists will explain
Validation of a New Scoring System for the Detection of Early Forme of Keratoconus
10.5005/jp-journals-10025-1019 Alain Saad, Damien Gatinel ORIGINAL ARTICLE Validation of a New Scoring System for the Detection of Early Forme of Keratoconus Alain Saad, Damien Gatinel ABSTRACT Purpose:
Keratoconus Lasers, Lenses & Boomerangs (the journey, missing links, and management & treatment options) Moderator: Jan P G Bergmanson, OD, PhD
2014 AAO CCLRT Section Symposium Keratoconus Lasers, Lenses & Boomerangs (the journey, missing links, and management & treatment options) Moderator: Jan P G Bergmanson, OD, PhD Recurrent Keratoconus: Does
Uncorrected astigmatism can cause visual
Spatial Vision and Astigmatism Correction What is the minimum amount of astigmatism that should be corrected? By Eloy A. Villegas, PhD; and Pablo Artal, PhD Uncorrected astigmatism can cause visual quality
Your one stop vision centre Our ophthalmic centre offers comprehensive eye management, which includes medical,
sight see OLYMPIA EYE & LASER CENTRE Your one stop vision centre Our ophthalmic centre offers comprehensive eye management, which includes medical, At the Olympia Eye & Laser Centre, our vision is to improve
How To Treat Eye Sight Problems With Eye Care
Dealing With The Refractive Surprise Richard S. Hoffman, MD Clinical Associate Professor of Ophthalmology Casey Eye Institute Oregon Health and Science University No Financial Interest Why The Surprise?
Ectasia Risk Scoring System (ERSS): Limitations and Variability in Predictive Value
Ectasia Risk Scoring System (ERSS): Limitations and Variability in Predictive Value Jay S. Pepose, M.D., Ph.D. Director, Pepose Vision Institute Professor of Clinical Ophthalmology Washington University
LASIK and Refractive Surgery. Laser and Lens Vision Correction Options
LASIK and Refractive Surgery Laser and Lens Vision Correction Options For over 30 years, The Eye Institute of Utah has been giving people vision for life... Dr. Andrew Lyle, vision pioneer and founder
By Dr Waleed Al-Tuwairqi, MD Dr Omnia Sherif, MD Ophthalmology Consultants, Elite Medical & Surgical Center Riyadh -KSA.
By Dr Waleed Al-Tuwairqi, MD Dr Omnia Sherif, MD Ophthalmology Consultants, Elite Medical & Surgical Center Riyadh -KSA Rome, Italy 2013 بسم الرحمن الرحيم In the name of Allah, Most Gracious, Most Merciful
Challenging Refractive Surgery Cases. Vance Thompson, MD, FACS Refractive and Cataract Surgery Vance Thompson Vision Sioux Falls, South Dakota
Challenging Refractive Surgery Cases Vance Thompson, MD, FACS Refractive and Cataract Surgery Vance Thompson Vision Sioux Falls, South Dakota Financial Disclosures Research/consulting: Alcon AMO B & L
The cataract laser technology of tomorrow is here for you today.
The cataract laser technology of tomorrow is here for you today. See inside to learn about all your exciting new options Thanks to new advancements, this is a great time to have cataract surgery Laser
New and Improved Femtosecond Laser Applications. Karl Stonecipher, MD Wavefront Congress 2008
New and Improved Femtosecond Laser Applications Karl Stonecipher, MD Wavefront Congress 2008 When birds don t fly, neither should you. When cows bunch together in a field, a storm is coming. When ants
INTRACOR. An excerpt from the presentations by Dr Luis Ruiz and Dr Mike Holzer and the Round Table discussion moderated by Dr Wing-Kwong Chan in the
INTRACOR An excerpt from the presentations by Dr Luis Ruiz and Dr Mike Holzer and the Round Table discussion moderated by Dr Wing-Kwong Chan in the 1 Dr Luis Ruiz Presbyopia treatment with INTRACOR Luis
Corneal Power Measurements Using Scheimpflug Imaging in Eyes With Prior Corneal Refractive Surgery
Corneal Power Measurements Using Scheimpflug Imaging in Eyes With Prior Corneal Refractive Surgery Jack T. Holladay, MD, MSEE, FACS; Warren E. Hill, MD, FACS; Andreas Steinmueller, MSc ABSTRACT PURPOSE:
New topographic custom ablation procedure for treating irregular astigmatism post keratoplasty with high frequency (1 KHz) excimer laser.
New topographic custom ablation procedure for treating irregular astigmatism post keratoplasty with high frequency (1 KHz) excimer laser. G. COLONNA M.D., G. Lorusso M.D., S. Santoro M.D. ESCRS Berlin
Overview of Refractive Surgery
Overview of Refractive Surgery Michael N. Wiggins, MD Assistant Professor, College of Health Related Professions and College of Medicine, Department of Ophthalmology Jones Eye Institute University of Arkansas
Customized corneal ablation can be designed. Slit Skiascopic-guided Ablation Using the Nidek Laser. Scott MacRae, MD; Masanao Fujieda
Slit Skiascopic-guided Ablation Using the Nidek Laser Scott MacRae, MD; Masanao Fujieda ABSTRACT PURPOSE: To present the approach of using a scanning slit refractometer (the ARK 10000) in conjunction with
Custom Cataract Surgery. Laser and Lens Options
Custom Cataract Surgery Laser and Lens Options What is a Cataract? More than fifty percent of people over the age of 60, and quite a few younger than that, suffer from cataracts. In fact, cataracts are
