BMC ProactiveNet Performance Management - Veritas Cluster Server Monitoring

Size: px
Start display at page:

Download "BMC ProactiveNet Performance Management - Veritas Cluster Server Monitoring"

Transcription

1 BMC ProactiveNet Performance Management - Veritas Cluster Server Monitoring User Documentation January 2013

2 Contacting BMC Software You can access the BMC Software Web site at From this Web site, you can obtain information about the company, its products, corporate offices, special events, and career opportunities. United States and Canada Outside United States and Canada Address BMC Software, Inc CityWest Blvd. Houston TX Telephone (01) Telephone or Fax (01) Fax Copyright 2006 BMC Software, Inc. or licensors, as an unpublished work. All rights reserved. BMC Software, the BMC Software logos, and all other BMC Software product or service names are registered trademarks or trademarks of BMC Software, Inc. IBM is a registered trademark of International Business Machines Corporation. DB2 is a registered trademark of International Business Machines Corporation. Oracle is a registered trademark, and the Oracle product names are registered trademarks or trademarks of Oracle Corporation. All other trademarks belong to their respective companies. BMC Software considers information included in this documentation to be proprietary and confidential. Your use of this information is subject to the terms and conditions of the applicable End User License Agreement for the product and the proprietary and restricted rights notices included in this documentation. Restricted Rights Legend U.S. Government Restricted Rights to Computer Software. UNPUBLISHED -- RIGHTS RESERVED UNDER THE COPYRIGHT LAWS OF THE UNITED STATES. Use, duplication, or disclosure of any data and computer software by the U.S. Government is subject to restrictions, as applicable, set forth in FAR Section , DFARS , DFARS , DFARS , and DFARS , as amended from time to time. Contractor/Manufacturer is BMC Software, Inc., 2101 CityWest Blvd., Houston, TX , USA. Any contract notices should be sent to this 2

3 You can obtain technical support by using the Support page on the BMC Software Web site or by contacting Customer Support by telephone or . To expedite your inquiry, please see "Before Contacting BMC Software." Support Web Site You can obtain technical support from BMC Software 24 hours a day, 7 days a week at From this Web site, you can Read overviews about support services and programs that BMC Software offers: Find the most current information about BMC Software products Search a database for problems similar to yours and possible solutions Order or download product documentation Report a problem or ask a question Subscribe to receive notices when new product versions are released Find worldwide BMC Software support center locations and contact information, including addresses, fax numbers, and telephone numbers Support by Telephone or In the United States and Canada, if you need technical support and do not have access to the Web, call Outside the United States and Canada, please contact your local support center for assistance. To find telephone and contact information for the BMC Software support center that services your location, refer to the Contact Customer Support section of the Support page on the BMC Software Web site at Before Contacting BMC Software Before you contact BMC Software, have the following information available so that Customer Support can begin working on your problem immediately: Product information product name product version (release number) license number and password (trial or permanent) Operating system and environment information machine type operating system type, version, and service pack or other maintenance level such as: PUT or PTF system hardware configuration serial numbers related software (database, application, and communication) including type, version, and service pack or maintenance level Sequence of events leading to the problem Commands and options that you used Messages received (and the time and date that you received them) product error messages 3

4 Table of Contents User Goals and Features...11 Business Value...11 Requirements...12 System Requirements...12 Software Requirements...12 Security Requirements...13 Adding Central Monitoring...18 Administration Tags Preparing for Installation Creating a Component Installation Package...23 Editing a Component Installation Package Downloading and Installing...24 an Installation Package...26 Configuring General Settings Managing Policies Configuring Monitor Settings Configuring Veritas Cluster...30 Server KM...30 Configuring the User Account Enabling the Debug Mode Configuring the Maximum Number of Instances Configuring the Multi-Node...39 Monitoring Mode Configuring the VCS Server...44 Discovery Overrides (Optional)...47 Filtering Elements to Monitor Configuring Thresholds Using BMC ProactiveNet Performance Management...50 Navigating the BMC ProactiveNet Operations Console...53 Adding attributes to the graph Viewing and manipulating...53 attribute graphs...54 Viewing monitors for a device Changing thresholds Managing Baselines and Key Performance Indicators Veritas Cluster Server KM...59 VCS Agent...60 VCS Daemon...60 Table of Contents 4

5 VCS GAB...61 VCS GAB Port...62 VCS Group System...62 VCS LLT...63 VCS LLT Interface...64 VCS LOG...64 VCS Resource...65 VCS Resource System...66 VCS Service Group...67 VCS System...68 VCS System Heartbeat...70 VCS WAN Heartbeat...70 Table of Contents 5

6 Support Information

7 This section contains information about how to contact Customer Support and the levels of support offered for this and other releases. If you have problems with or questions about a BMC product, or for the latest support policies, see the Customer Support website at You can also access product documents and search the Knowledge Base for help with an issue at If you do not have access to the web and you are in the United States or Canada, contact Customer Support at Outside the United States or Canada, contact your local BMC office or agent. 7

8 Legal Notices

9 Copyright 2011 BMC Software, Inc. BMC, BMC Software, and the BMC Software logo are the exclusive properties of BMC Software, Inc., are registered with the U.S. Patent and Trademark Office, and may be registered or pending registration in other countries. All other BMC trademarks, service marks, and logos may be registered or pending registration in the U.S. or in other countries. All other trademarks or registered trademarks are the property of their respective owners. Linux is the registered trademark of Linus Torvalds. Oracle and Java are registered trademarks of Oracle and/or its affiliates. Other names may be trademarks of their respective owners. UNIX is the registered trademark of The Open Group in the US and other countries. The information included in this documentation is the proprietary and confidential information of BMC Software, Inc., its affiliates, or licensors. Your use of this information is subject to the terms and conditions of the applicable End User License agreement for the product and to the proprietary and restricted rights notices included in the product documentation. BMC Softw are Inc CityW est Blvd, Houston TX , USA Customer Support: (United States and Canada) or contact your local support center 9

10 Key Concepts

11 The pages in this section provide a high-level overview of the product. User Goals and Features Business Value Requirements Note that for convenience and brevity, reference to BMC ProactiveNet Performance Management - Veritas Cluster Server Monitoring, may also be made as Veritas Cluster Server KM. User Goals and Features Veritas Cluster Server KM enables you to monitor: Systems: each cluster node health, including the critical processes and system status. Heartbeats: monitors the heartbeats between nodes and global clusters. LLT & GAB: monitors both LLT and GAB protocol health and memberships. Resources & Service Groups: monitors the status of resources and their member system status. Logs: checks for any errors in VCS logs and system logs regularly. Agents: monitors the status of VCS agents for successful failover. Automatic KM Failover: in the event of a VCS failover, the KM continues the monitoring through the new active node. Business Value provides current and historical information through a centralized console so you can easily view and manage your entire Veritas Cluster Server environment. The product collects and brings critical performance data and useful metrics into the BMC ProactiveNet Performance Management environment and enables Veritas Administrators and affected business units to be warned whenever a problem occurs in their Veritas Cluster Server environment. : Enhances productivity Ensures VCS core components are available at all times Provides an end-to-end monitoring of Veritas clusters by integrating with clustered application monitoring. 11

12 Requirements Before installing the Veritas Cluster Server KM, verify the: software requirements system requirements security requirements. System Requirements The following list shows the operating systems and their versions supported by BMC ProactiveNet Performance Management - Veritas Cluster Server Monitoring. Microsoft Windows Server 2003 and 2008, all versions supported by BMC PATROL Agent 3.7 and greater Linux, all distributions supported by BMC PATROL Agent 3.7 and greater Sun Solaris 8, 9, 10, supported by BMC PATROL Agent 3.7 and greater HP-UX 11, supported by BMC PATROL Agent 3.7 and greater IBM AIX 5.x and 6.x, supported by BMC PATROL Agent 3.7 and greater Software Requirements The following table contains a list of required software and their versions supported by BMC ProactiveNet Performance Management - Veritas Cluster Server Monitoring. Software Version Veritas Cluster Server 4.0 (all multi-packs) 4.1 (all multi-packs) 5.0 (all multi-packs) 6.0 (all multi-packs) BMC Software PATROL Agent 3.7.x, 3.8.x, 3.9.x, 9.x BMC Software PATROL Console 3.4.x, 3.5.x, 7.x BMC ProactiveNet Performance Management Portal 2.3.x, 2.4.x, 2.5.x, 2.6.x, 2.7.x, 2.8.x BMC ProactiveNet Performance Manager 8.x, 8.5.x, 8.6.x, 9.x If the version of Veritas Cluster Server is upgraded (or dow ngraded) at a later date, you w ill need to reload commands for the VCS KM. Requirements 12

13 Additional Software Requirements The following table contains a list of additional software requirements of BMC ProactiveNet Performance Management - Veritas Cluster Server Monitoring. Purpose Software Version When running VCS KM with sudo user account on Solaris, HP-UX, AIX or Linux managed nodes Sudo (superuser do) or later When running VCS KM on Linux managed nodes Korn shell binary (/bin/ksh) Any When running VCS KM on Microsoft Windows x64 managed nodes Reg.exe patch KB ( kb/948698) Any The Microsoft W indow s x64 Reg.exe patch, KB is required to allow access to 64-bit registry keys from PATROL Agent. Access the above patch site from the managed node to obtain the correct patch for that platform. Security Requirements A user account with administrative privileges must be configured in BMC PATROL to read and execute Veritas Cluster Server application programs and access file systems. Depending on the operating systems used, several options will be available. The following user accounts can be used: On Unix platforms: a root user a non-root user, such as patrol, that has sudo privileges on Veritas Cluster Server to execute application programs and access file systems a non-root account, such as patrol, configured in Veritas Cluster Server application to administer the Veritas Cluster Server application. On Windows platforms: an administrator user a non-administrator account, such as patrol, configured in Veritas Cluster Server application to administer the Veritas Cluster Server application. The user login details are configured in the KM. The password is stored in the PATROL Agent in a DES encrypted format. The encrypted password can be viewed by any user who has access to the PATROL Agent configuration variables (pconfig). This user could then execute PSL statements using the encrypted password through the PATROL Console. This can be prevented by setting up an appropriate Access Control List (ACL) for users. Please refer to the PATROL Agent Reference Manual for details on how to set up an ACL. Requirements 13

14 Access Permissions The Veritas Cluster Server KM needs read & execute permission to executable and library files under the paths listed below.the Veritas Cluster Server installation path INSTALL_PATH, referenced in the tables below, is normally /opt/vrtsvcs (on Unix) or C:\Program Files\Veritas (on Microsoft Windows). Paths Microsoft Windows INSTALL_PATH/bin/ha* INSTALL_PATH\Cluster Server\bin\ha* /sbin/llt* INSTALL_PATH\comms\llt* /sbin/gab* INSTALL_PATH\comms\gab* INSTALL_PATH/lib INSTALL_PATH\Cluster Server\lib /usr/lib INSTALL_PATH\Cluster Server The Veritas Cluster Server KM includes some scripts which should be executable by the PATROL Agent user and the Veritas Cluster Server KM user. These scripts are stored under KM_HOME path, normally PATROL_HOME/lib/VCS. To list all OS commands used by the Veritas Cluster Server KM, execute the following PSL code from the PATROL Console, using PSL Task menu, after installing and loading the KM. i=0; sudoers=""; foreach var (grep("^/runtime/vcs/commandcontrols/",pconfig("list"))) { ctl=get(var); opt=ntharg(grep("option",ctl),"2-"," ="); nsa=ntharg(grep("nosudoattempt",ctl),"2-"," ="); sua=ntharg(grep("singleuserattempt",ctl),"2-"," ="); typ=ntharg(grep("commandtype",ctl),"2-"," ="); cmd=nthargf(grep("commandtext",ctl),"2-","=","="); if((typ == "") (typ == "OS")) { met=""; if(opt == "NoLogin") { met = "(run as patrol user)"; } elsif(nsa == "YES") { met = "(run as configured user without sudo)"; } elsif(sua == "YES") { met = "(run as supplied user - used in menu)"; } else { scmd=cmd; s=index(scmd,"%sudo"); if(s) { scmd=replace(substr(scmd,s,length(scmd)),"%sudo",""); } sudoers=union(sudoers,ntharg(ntharg(scmd,1," "),"1-"," "," ")); } printf("(%2d) %-30s %-40s: %s\n",i++,ntharg(var,"5","/"),met,cmd); } } printf("\n\ncommands used with sudo:\n%s",sort(sudoers)); The PATROL Agent user (normally patrol) needs read permission to the following files: UNIX Microsoft Windows /var/vrtsvcs/log/engine_a.log INSTALL_PATH\Cluster Server\log\engine_A.txt /var/vrtsvcs/log/hashadow-err_a.log INSTALL_PATH\Cluster Server\log\hashadow-err_A.txt Requirements 14

15 /var/adm/messages (on Solaris) /var/adm/syslog/syslog.log (on HP-UX) /var/log/messages (on Linux) If a monitored log file cannot be read by the PATROL Agent user, it will be copied to KM_TEMP path using the configured login account, and processed by the PATROL Agent user. On completion the copied log file will be removed. This may increase the file system usage under KM_TEMP temporarily during this activity. On Windows platforms the Veritas Cluster Server installation is identified by checking the Microsoft Windows Registry: HKEY_LOCAL_MACHINE\SOFTWARE\Veritas\VCS\ The configured login user should have sufficient privileges to run regedit command on the managed node. Sudo User for Operating System Access If a non-root user with sudo privileges is preferred as the Veritas Cluster Server KM user, configure the account as a sudoer through the visudo utility using code appropriate for your platform as detailed below. This user should be able to execute VCS commands and OS commands. The code below also applies to all non-root users who may execute Veritas Cluster Server KM administration and report menu commands using their sudo privileges. The Veritas Cluster Server KM accepts any non-root user with the following sudo configuration in the sudoers file. Please replace user1, user2, user3 with appropriate KM user name. The Veritas Cluster Server installation path INSTALL_PATH, referenced below is normally /opt/vrtsvcs and PATROL_HOME is the path where the PATROL Agent is installed (including the target, like /opt/bmc/patrol3/solaris29-sun4/). This non-root sudo user configured in the KM will be able to execute Veritas Cluster Server commands. To prevent unauthorized access, ensure this user is only used within the KM and not made public for general use. Entering the non-root sudo user with Use Sudo option selected in to the login configuration dialog, before updating the sudoers file, will generate sudo errors. Also if the sudo user is configured differently, the KM may run sudo commands using incorrect sudo settings, which may expose the sudo user password. On Solaris: User_Alias VCSKMUSERS = user1, user2, user3 Defaults:VCSKMUSERS!lecture,!authenticate,\ env_keep+="ld_library_path INSTALL_PATH KM_HOME \ KM_TEMP",env_reset VCSKMUSERS ALL=/bin/*,/sbin/*,/usr/bin/*,/usr/sbin/*,\ INSTALL_PATH/bin/ha*,\ PATROL_HOME/lib/VCS/*,PATROL_HOME/bin/* Requirements 15

16 user1, user2, user3 must be replaced w ith username(s) used by the KM; INSTALL_PATH and PATROL_HOME w ith the relevant paths. On HP-UX: User_Alias VCSKMUSERS = user1, user2, user3 Defaults:VCSKMUSERS!lecture,!authenticate,\ env_keep+="shlib_path INSTALL_PATH KM_HOME \ KM_TEMP",env_reset VCSKMUSERS ALL=/bin/*,/sbin/*,/usr/bin/*,/usr/sbin/*,\ INSTALL_PATH/bin/ha*,\ PATROL_HOME/lib/VCS/*,PATROL_HOME/bin/* user1, user2, user3 must be replaced w ith username(s) used by the KM; INSTALL_PATH and PATROL_HOME w ith the relevant paths. On AIX & Linux: User_Alias VCSKMUSERS = user1, user2, user3 Defaults:VCSKMUSERS!lecture,!authenticate,\ env_keep+="libpath INSTALL_PATH KM_HOME \ KM_TEMP",env_reset VCSKMUSERS ALL=/bin/*,/sbin/*,/usr/bin/*,/usr/sbin/*,\ INSTALL_PATH/bin/ha*,\ PATROL_HOME/lib/VCS/*,PATROL_HOME/bin/* user1, user2, user3 must be replaced w ith username(s) used by the KM; INSTALL_PATH and PATROL_HOME w ith the relevant paths. Requirements 16

17 Planning

18 Adding Central Monitoring Administration Tags Adding Central Monitoring Administration tags should be taken into consideration before installation. A policy specifies a set of actions to be taken when a specific condition on the BMC PATROL Agent is fulfilled. A policy enables you to perform the following actions: Apply specific configuration to one or more BMC PATROL Agents Configure thresholds and set baselines on BMC ProactiveNet Child Servers Each policy is assigned a BMC ProactiveNet Central Monitoring Administration tag and each BMC PATROL Agent can have one or more tags assigned to it. When you assign a tag to a BMC PATROL Agent the associated policy is applied to the PATROL Agent. You can assign the tag value of a policy to a PATROL Agent in the following ways: You can add a PATROL Agent and set the tag as part of the configuration process that you perform from Central Monitoring Administration. For details, see Managing downloads in Central Monitoring Administration. If the PATROL Agent has already been installed, use PATROL Configuration Manager to set the following ruleset that provides the tags: /AgentSetup/Identification/Tags/TAG/tagName =tagdescription For example if the tag which has to be applied is oracletag, the ruleset is as follows /AgentSetup/Identification/Tags/TAG/oracleTag= ORACLE MONITORING In BMC ProactiveNet version 9.0, the tag description is ignored, and only the tag name is used to evaluate the policy. Adding Central Monitoring Administration Tags 18

19 Installing

20 The creation of the Veritas Cluster Server KM installation package is performed directly from BMC ProactiveNet Central Monitoring Administration. An installation package for a component can be downloaded and installed on several servers. The component installation package can be edited and saved under a new name. With Central Monitoring Administration, administrators select monitor installation components, such as the BMC PATROL Agent and monitoring solutions, from a repository to create an installation package. The components can then be installed together using the installation package. Administrators can reuse the installation packages, or deploy the packages to multiple computers. Preparing for Installation The BMC ProactiveNet Central Monitoring Repository is a requirement on the BMC ProactiveNet Central Server where Central Monitoring Administration is enabled. The Central Monitoring Repository includes the current versions of BMC components that you can use with BMC ProactiveNet. After creating a component installation package, administrators can save the package to the Monitoring Installation Packages list for future use, or download the package on the current host without saving the package. For saved packages, administrators can download and install the package on any host, or edit a package. For supported 64-bit Linux versions, you must install the Linux runtime package, glibc.i686, version or later. W ithout the Linux runtime package, BMC ProactiveNet component installations might fail. For further details regarding the BMC ProactiveNet Central Monitoring Administration, please refer to the BMC documentation. 20

21 Creating a Component Installation Package If you want to import the entire repository, first download Central Monitoring Repository files from the BMC Electronic Product Distribution (EPD) facility, or copy the files from your installation kit, to the BMC ProactiveNet Central Server file system. To import a single or custom solution 1. In the navigation pane of Central Monitoring Administration, click the Repository drawer and select Manage Repository. 2. Click Import. 3. In the Import a New Solution dialog box, select Single solution or Custom solution. 4. Browse to a source file in one of the following formats: zip, tar, or tar.gz. The solution must be located on the local computer from which you are running the Central Monitoring Administration web-based console. 5. (Custom solution, only) provide the following details: Custom solutions name: The name of the custom solution, as it will be displayed in Central Monitoring Administration. Custom solution version: The version number for the custom solution. Values in the first two version boxes are required. 6. Click Import. The selected archive file is imported to the repository and extracted. You can close the window during the import process. Creating a Component Installation Package 21

22 To create a component installation package 1. In the navigation pane of Central Monitoring Administration, click the Repository drawer and select Monitoring Repository. 2. Click Add. 3. Select the operating system for which you want to create a package, and then select a platform on which you want to install the package. The list of components in the repository that are supported on the specified operating system and platform is displayed. 4. From the Available components list, select components that you want to include in the package. 5. From the Version list, select the version of the component that you want to include in the package. You can select a specific version or you can select latest, which automatically updates the package with the latest versions of the components when new versions of those components are added to the Central Monitoring Repository. By default, the appropriate BMC PATROL Agent for the operating system and platform that you chose is included in the Selected components list. 6. Click the right arrow button to move the selected components into the Selected Components list, and then click Next. The installation wizards for the products that you selected are displayed. They'll vary depending on the products or components that you selected to include in the package. Go through the wizards to complete the installation. 7. The Installation Package Details is displayed. Verify that the operating system and platform are correct for the type of package that you want to create. Also verify that the components that you want to include are listed in the Included Components list. Provide the following information: Name: Enter a unique name for the package. (Optional) Description: Enter a description of the package. The description is displayed in the Monitoring Installation Packages list on the Monitoring Repository window. Format: Select a file compression format for the package. 8. Perform one or both of the following actions: To save the package for future installation on the current host or other hosts, click Save Installation Package. The package is available in the Monitoring Installation Packages list. To download the package immediately, click Download. If you click Dow nload and do not click Save Installation Package, the package is not saved in the Monitoring Installation Packages list for later use or editing. 9. When you are finished, click Close. Creating a Component Installation Package 22

23 Editing a Component Installation Package You can edit any part of an existing component installation package except the operating system and platform. 1. In the navigation pane of Central Monitoring Administration, click the Repository drawer and select Monitoring Repository. 2. (Optional) To filter the list of packages, select an operating system from the Filter by Operating System list. 3. Select the row for a package and click Edit. 4. From the Available components list, add or remove components, and click Next. 5. Perform one or more of the following actions, depending on your requirements: Edit the installation details of existing components. Add installation details for new components. Click Finish Update to skip to the Installation Package Details window. If you add a component to the package, you must complete the configuration process. The Finish Update button show s an explanatory tooltip and does not skip to the Installation Package Details w indow. 6. In the Installation Package Details window, modify the following information as needed: Name: To save your changes to the same package, do not change the name. To save the package under a unique name, change the name. (Optional) Description: Enter a description of the package. The description is displayed in the Monitoring Installation Packages list on the Monitoring Repository window. Format: Select a file compression format for the installation package. 7. Perform one or both of the following actions: To save the package for future installation on the current host or other hosts, click Save Installation Package. The package is available through the Monitoring Installation Packages list. To download the installation package immediately, click Download. If you click Dow nload and do not click Save Installation Package, the changes are not saved in the Monitoring Installation Packages list for later use or editing. 8. When you are finished, click Close. Editing a Component Installation Package 23

24 Downloading and Installing an Installation Package You can download an installation package and install the components on one or more hosts. The installation runs silently with the information entered during package creation. Recommendation If you defined the BMC ProactiveNet Integration Service variable for PATROL Agents in the installation package, ensure the agents are started in phases. Do not start newly deployed agents all at once. Start and configure monitoring for the agents in planned phases to reduce the performance impact on the Integration Service nodes and on the BMC ProactiveNet Server associated with the automatic workflow process. To download and install an installation package 1. From the computer on which you want to install the package, log on to BMC ProactiveNet Central Monitoring Administration. 2. (Optional) To filter the list of installation packages, select an operating system from the Filter by Operating System list. 3. Click the link for the installation package that you want to download. 4. Through the browser's download dialog box, save the installation package. 5. Extract the installation package as appropriate for your operating system. The package is extracted to the bmc_products directory on the current host. 6. From the bmc_products directory, run the installation utility for your operating system: (UNIX or Linux) RunSilentInstall.sh (Microsoft Windows) RunSilentInstall.exe The package is installed on the current host. If the package includes a BMC PATROL Agent, the agent sends a configuration request by passing its tags to BMC ProactiveNet Central Monitoring Administration, via the Integration Service. Central Monitoring Administration evaluates policies that match the tags, determines the final configuration to be applied, and sends the configuration information back to the agent. Monitoring is based on the configuration information received by the agent. If no policy matches the tags associated with the agent, the agent does not receive configuration information. The agent does not begin monitoring until a matching policy is created. For further information regarding the Repository management, please refer to the BMC ProactiveNet Central Monitoring Administration documentation. Downloading and Installing an Installation Package 24

25 Configuring After Installation

26 You configure monitoring of Veritas Cluster Server KM when you create a policy. A policy is a template containing the configuration of a PATROL Agent. A policy can be assigned to one or more PATROL Agents using a unique tag (Central Monitoring Administration tag), and a PATROL Agent can be assigned one or more policies with different priorities. If you have not already added the Central Monitoring Administration tag to your PATROL Agents during the solution installation, then you must manually assign the tag after you have configured the policy. For details, see Adding Central Monitoring Administration Tags. Configuring General Settings Through the General tab of the Add Policy dialog, you can create a new policy. A policy specifies a set of actions to be taken when a specific condition on the PATROL Agent is fulfilled. First and foremost, actions include monitor configuration. Once a monitor is configured, policies can also specify threshold creation and the setting of baselines. A policy can also include intelligent server-side thresholds so that IT administrators can immediately be alerted on potential problems. Field Instructions Name Enter a policy name. Policy names must be unique. In an environment with tenants, policy names must be unique for a single tenant Tenant (For environments with tenants) Select a tenant name. See Policies and tenants for details. Global indicates a policy applicable to all tenants. Enable policy Select this option to enable the policy, or clear the option to disable the policy. The option is selected by default. If you clear the option, the policy and its associations remain intact, but the policy configuration is not applied until the policy is enabled again. Precedence Enter a number from 0 to 999. Description (Optional) Enter a policy description. Tag Enter a Central Monitoring Administration tag. Policies are applied to BMC PATROL Agents with matching tags. Tags are case sensitive and cannot contain spaces or any of the following characters: /, \, {, }, <, >,,, &. Provider indicates a policy applicable to the cloud service provider Policy precedence When more than one policy is applied to a BMC PATROL Agent and BMC ProactiveNet Child Server, configuration is a union of every attribute defined by the policies. If a conflict arises (that is, two policies configure the same attributes), it is resolved in one of the following ways: Policies with the same tag: If conflicting policies have the same tag, the precedence value determines the order the policies are applied. The policy with the lower number value for precedence is the policy from which the final configuration is applied. Policies with different tags: If conflicting policies have different tags, then the policies are applied according to the order they are listed on the BMC PATROL Agent. The policy listed last on the agent is the policy from which the final configuration is applied. 26

27 Managing Policies This topic provides general instructions for the following policy management tasks: editing, deleting, enabling and disabling. Before you begin Enable Central Monitoring Administration and log on to Central Monitoring Administration. Refer to the BMC documentation and more especially to the section Enabling and configuring Central Monitoring Administration for details. Policies w ith only threshold configuration or server side configuration are applicable only after a policy w ith monitor configuration is applied. To edit a monitoring policy 1. In the navigation pane of Central Monitoring Administration, click the Policies drawer and select a policy view. 2. Select a policy and click Edit. 3. Edit the Configuring general settings of the policy. 4. Edit information on one or more of the following tabs: Configuring monitor settings. Configuring threshold settings. 5. Click Update. To delete a monitoring policy Deleting a policy deletes all monitor instances and most settings configured through the policy. Devices remain in the User Groups to which they have been added. 1. In the navigation pane of Central Monitoring Administration, click the Policies drawer and select a policy view. 2. Select one or more policies and click Delete. 3. Click Yes to confirm deletion. To enable or disable a monitoring policy Enable or disable policies for maintenance and troubleshooting. When a policy is disabled, the policy and its associations remain intact, but the policy configuration is not applied until the policy is enabled again. 1. In the navigation pane of Central Monitoring Administration, click the Policies drawer and select a policy view. 2. Select one or more policies and click Enable or Disable. Configuring General Settings 27

28 Configuring Monitor Settings When you create or edit a policy, you can add and configure monitor types. The Add Monitor Types dialog box presents configuration fields for compatible BMC PATROL monitoring solutions that are located in the Central Monitoring Repository. For a list of monitoring solutions that you can configure through Central Monitoring Administration, see the Monitoring solutions configurable through Central Monitoring Administration chapter in the BPPM online documentation. For configuration details for a specific monitor type, see the monitor documentation. To configure custom monitoring solutions through Central Monitoring Administration, ensure the solution is structured correctly; for details, see the Building a PATROL Know ledge Module Developers Guide on BMC Support website. To configure the Monitor Type settings using the Add Monitor Types dialog box To add a monitor type: 1. In the navigation pane of Central Monitoring Administration, click the Policies drawer and select a policy view. 2. Click Add to display the Add Policy dialog box. 3. Configure the policy general settings. 4. Click the Monitor Configuration tab. Configuring Monitor Settings 28

29 5. Click Add A dding Monitor Types 6. From the Solution menu, select Veritas Cluster Server. 7. From the Version menu, select the required version. 8. From the Monitor Type menu, select the required monitor: Monitor Type Description Veritas Cluster Server KM To set the general settings of Veritas Cluster Server KM (credentials, debug mode, instances, multinode mode, etc.) VCS Agent Enables access to the filtering options to select the VCS Agents elements that will be monitored. VCS Daemon Enables access to the filtering options to select the daemons elements that will be monitored. VCS GAP Port Enables access to the filtering options to select the GAB ports elements that will be monitored. VCS Group System Enables access to the filtering options to select the VCS group systems elements that will be monitored. Configuring Monitor Settings 29

30 VCS LLT Interface To set filtering options that indicate the VCS LLT interfaces to monitor. VCS Resource To set filtering options that indicate the VCS Resources to monitor. VCS Resource System To set filtering options that indicate the VCS Resource Systems to monitor. VCS Service Group To set filtering options that indicate the VCS Service Groups to monitor. VCS System To set filtering options that indicate the VCS Systems to monitor. VCS System Heartbeat To set filtering options that indicate the VCS System Heartbeats to monitor. VCS WAN Heartbeat To set filtering options that indicate the VCS WAB Heartbeats to monitor. Configuring Veritas Cluster Server KM Before using Veritas Cluster Server KM, you'll have to configure its general settings. This section will learn you how to: configure the user account enable the debug mode configure the maximum number of instances configure the multi-node monitoring mode configure the VCS server discovery overrides (Optional). Configuring the User Account A user account with administrative privileges must be configured in BMC ProactiveNet to read and execute Veritas Cluster Server application programs and file systems. Depending on the operating systems used, several options will be available. On Unix platforms, you can use the following user accounts: a root user a non-root user, such as patrol, that has sudo privileges on Veritas Cluster Server to execute application programs and access file systems a non-root account, such as patrol, configured in the Veritas Cluster Server application to administer the Veritas Cluster Server application. On Windows platforms, you can use the following user accounts: Configuring Monitor Settings 30

31 an administrator user a non-administrator account, such as patrol, configured in the Veritas Cluster Server application to administer the Veritas Cluster Server application. To configure the user account 1. Add or edit a monitor type 2. From the Monitor Type menu, select Veritas Cluster Server KM Configuring Monitor Settings 31

32 3. In the Hostname field, enter: localhost to apply these settings to all PATROL Agents installed on the VCS Servers a hostname or IP address to apply these settings to a specific server 3. Set the VCS Credentials: To use the default PATROL Agent Account, check the Use Agent Default Account box To use a different user account, enter the login details in the Username and Password fields (Unix Only) If the user account has sudo privileges, check the Use Sudo box and indicate the sudo binary file path (by default: /usr/local/bin/sudo) 5. Click the Advanced button if you need to configure: the debug mode the maximum number of instances the multi-node monitoring mode the VCS Server discovery overrides (Optional). 6. Click Add to List. 7. Click Update. Enabling the Debug Mode When you encounter an issue and wish to report it to Sentry Software, you will be asked to enable the Debug Mode and provide the debug output to the Sentry Software support team. To enable the debug mode 1. Edit a Veritas Cluster Server KM monitor type: In the navigation pane of Central Monitoring Administration, click the Policies drawer and select a policy view Select a policy and click Edit In the Monitor Configuration tab, select Veritas Cluster Server KM monitor type and click Edit Configuring Monitor Settings 32

33 Editing the V CS Monitoring Settings Configuring Monitor Settings 33

34 2. From the List - VCS Monitoring Settings, select the host or localhost 3. Click the Advanced button A dvanced Settings Configuring Monitor Settings 34

35 4. Click the Debug button Configuring the Debug Mode 5. Select all the elements for which you want to obtain debug information 6. In the Options section, indicate: when the system must stop logging debug information. The required format is: YYYY/MM/DD HH:MM:SS where the debug file will be stored. The default path is: <PATROL_HOME>/lib/VCS/debug 7. Click Close on all pop-ups 8. Click Modify Selection in the main window and click Update. When the debug end time is reached, a tar/zip file is automatically created under <PATROL_HOME>/ lib/vcs/ and can be sent to the BMC Support for help. It is also recommended to check the VCS.log file, stored in <PATROL_HOME>/log, for any error. Configuring Monitor Settings 35

36 Configuring the Maximum Number of Instances By default, the solution discovers and monitors all the instances. Because there may be a very large number of instances to monitor and this may represent a important workload to the agents and the BPPM servers, it is recommended to only monitor the critical ones. This can be done by configuring the instance limits. 1. Edit a Veritas Cluster Server KM KM monitor type: In the navigation pane of Central Monitoring Administration, click the Policies drawer and select a policy view Select a policy and click Edit In the Monitor Configuration tab, select a Veritas Cluster Server monitor type and click Edit Editing the V CS Monitoring Settings Configuring Monitor Settings 36

37 2. From the List - VCS Monitoring Settings, select the host or localhost 3. Click the Advanced button A dvanced Settings Configuring Monitor Settings 37

38 4. Click the Instance Max button For each monitored element, indicate the maximum number of instances to be displayed Enter 0 in the relevant field to disable the monitoring of a specific element Click Close on all pop-ups Click Modify Selection in the main window and click Update. Configuring Monitor Settings 38

39 Configuring the Multi-Node Monitoring Mode If the Veritas Cluster Server environment is installed in a cluster using Veritas Cluster Server, Veritas Cluster File System, Oracle Solaris Cluster or Microsoft Cluster, Veritas Cluster Server KM must be installed on all the cluster nodes to enable continuous monitoring and avoid single point of failure. To avoid duplicate alerts from multiple nodes, it is recommended to configure the solution to operate in multi-node monitoring mode. To configure the multi-node monitoring mode 1. Edit a Veritas Cluster Server KM monitor type: In the navigation pane of Central Monitoring Administration, click the Policies drawer and select a policy view Select a policy and click Edit In the Monitor Configuration tab, select Veritas Cluster Server KM monitor type and click Edit Configuring Monitor Settings 39

40 Editing the V CS Monitoring Settings Configuring Monitor Settings 40

41 2. From the List - VCS Monitoring Settings, select the host or localhost 3. Click the Advanced button A dvanced Settings Configuring Monitor Settings 41

42 4. Select Enable Multi-node Monitoring Mode and click the Multi-node M... button Configuring Multi-node Mode 5. Configure the Multi-node Mode: Select the appropriate Cluster Application. Indicate the Failover Group Name. Leave this field blank if you have previously selected Veritas Cluster File System. Then the Veritas Cluster Server KM will monitor the entire cluster from the active master system, which is identified by vxdctl -c mode command. This method requires vxconfigd in enable mode with its clustered state active. In the Monitoring Node Names field, name all the VCS systems where the monitoring solution is installed. The list must be delimited by commas. 6. (Optional) Allow the solution to check the monitoring mode of the remote PATROL Agents. If the Remote PATROL Agent Checking is disabled, the solution will monitor actively through active VCS Server system or on the node where failover group is online and will not check the monitoring status of the other nodes through PATROL Agent: Check the Enable Remote PATROL Agent Checking box. Click the Remote Agent button Configuring Monitor Settings 42

43 Configuring the Remote A gent In the Monitoring Node Name field, indicate the cluster node used for multi-node mode failover Indicate all the information required to communicate with the remote PATROL Agent (protocol, port number, and credentials) In the Number of Attempts field, indicate how many times the solution will try to communicate with the remote PATROL Agent before failing over Enter the timeout between attempts Click Add to List Resume the procedure for all the nodes previously listed in step 5 7. Click Close on all pop-ups 8. Click Modify Selection in the main window and click Update. Veritas Cluster Server will then be monitored through the active or online node. The other nodes, which are standing by for a failover, will be in passive multi-node mode and only the local Veritas Cluster Server components will be monitored. Configuring Monitor Settings 43

44 If a managed node is unable to determine the system w hich should be in Active Multi-node Mode, it w ill change to Temporary Single-node Mode. Configuring the VCS Server Discovery Overrides (Optional) The solution automatically discovers the Veritas Cluster Server installation and configuration paths, the temporary directory path used by the VCS KM, the node type, and the node status. This information can however be overridden. To configure VCS server discovery overrides 1. Edit a VCS KM monitor type: In the navigation pane of Central Monitoring Administration, click the Policies drawer and select a policy view Select a policy and click Edit In the Monitor Configuration tab, select a Veritas Cluster Server KM monitor type and click Edit Configuring Monitor Settings 44

45 Editing the V CS Monitoring Settings Configuring Monitor Settings 45

46 2. From the List - VCS Monitoring Settings, select the host or localhost 3. Click the Advanced button A dvanced Settings 4. In the VCS Server Discovery Overrides section, indicate: the VCS installation path the VCS configuration path the temporary directory path the node status. 5. Click Close on all pop-ups 6. Click Modify Selection in the main window and click Update. Configuring Monitor Settings 46

47 Filtering Elements to Monitor By default, the solution monitors all the elements discovered, which may represent an important workload to the agents and the BPPM servers. Because the monitoring of some elements may be irrelevant for various reasons, you can apply filters to indicate which elements will be monitored or not. Filtering options are available for the following monitor types: VCS Agent, VCS Daemon, VCS GAB Port, VCS Group System, VCS LLT Interface, VCS Resource, VCS Resource System, VCS Service Group, VCS System, VCS System Heartbeat, and VCS WAN Heartbeat. To filter elements to monitor 1. Add or edit a monitor type 2. Select the Monitor Type for which you wish to apply filters. 3. In the Hostname field, enter: localhost to apply these settings to all PATROL Agents installed on Veritas Cluster Servers a hostname or IP address to apply these settings to a specific server 4. Indicate which elements will be monitored: Click the Filtering button In the Keep Only... section, indicate the regular expression for the element to be monitored and click Add to List In the Exclude... section, indicate the regular expression for the element not to be monitored and click Add To List Resume procedure to keep and/or exclude as many elements as required Click Close 5. If needed, manually add elements to be monitored: Click the Manual Add button Indicate the element to be monitored and click Add to List Resume procedure to add as many elements as required Click Close 6. Click Add to List. 7. Click Add. 8. Finally, Update the policy. Configuring Thresholds When you are creating or editing a policy, you can add and configure monitor thresholds. The Add Thresholds dialog box presents threshold configuration fields for BMC ProactiveNet monitors that are configured through Central Monitoring Administration. For details about baselines and Key Performance Indicators (KPI), see BMC ProactiveNet Central Monitoring Administration or BMC ProactiveNet documentation or refer to the Managing Baselines and Key Performance Indicators section. For details about the monitored attributes, refer to the specific monitor type in the Reference Guide section. Configuring Monitor Settings 47

48 Before you begin Ensure that monitor configuration is complete before thresholds are applied. Thresholds cannot be applied to monitors that are not configured through Central Monitoring Administration. If you have not done so already, define general policy details. To add and configure monitor thresholds 1. Open the Add Policy dialog box. Click for steps: In the navigation pane of Central Monitoring Administration, click the Policies drawer and select a policy view. Click Add, or select an existing policy and click Edit. 2. Select the Threshold Configuration tab and click Add. 3. In the Add Thresholds dialog box, select an item from each of the following lists: Solution, Version, and Monitor Type. Configuration fields are displayed. 4. In the Scope list, the Instance option is automatically selected. Type an Instance Name string or regular expression to apply threshold configuration to instances with matching patterns. Select Match Device Name to include the associated device and use the entire <devicename> \<instancename> string for pattern matching. Instance thresholds are applied to the matched monitor instance names or instance names patterns. You can use the following regular expression patterns for the instance name:?, +, *, ( ),, [ ], { }, ^, $,. If the instance name contains one of the pattern characters (except for *), use a backslash ( \ ) before the pattern character. For example, to enter the instance name Storage1 (1), enter Storage1 \(1\). 5. From the Attribute list, select a monitor attribute. In the Attribute list, some attributes are designated as key performance indicators (KPIs). Depending on the monitored environment and version, the list of KPIs might appear differently in the BMC ProactiveNet Operations Console. 6. From the Type of Threshold list, select the threshold type. 7. Select and enter values for the threshold parameters. 8. To continue configuration, perform one or more of the following actions in the Add Thresholds dialog box, and then select a different monitor type, version, or solution: To add the configuration details for the threshold to the Threshold Configuration tab, click the Add button at the bottom of the window. To return the settings in the current window to default values, click the Reset button at the bottom of the window. The values on the current window are reset. Be sure to click the Add button to save the configuration on the Threshold Configuration tab. 9. When you finish configuration, click Close. The configuration details are displayed in the table on the Threshold Configuration tab. 10. When you finish configuring thresholds, click Save at the bottom of the Add Policy dialog box, or Update at the bottom of the Edit Policy dialog box. After you save or update the policy, new threshold configurations are pushed to BMC PATROL Agents with matching Central Monitoring Configuration tags. Configuring Thresholds 48

49 To edit a threshold configuration On the Threshold Configuration tab, select a threshold definition, and click Edit. Edit the configuration values and click Update. When you finish editing the threshold configuration, click Close. To save changes to the policy, click Update at the bottom of the Edit Policy dialog box. After you update the policy, updated threshold configurations are pushed to BMC PATROL Agents with matching Central Monitoring Configuration tags. To delete a threshold configuration 1. On the Threshold Configuration tab, select attributes, monitor types, versions, or solutions. 2. Click Delete. 3. After you delete one or more threshold configurations, click Close. 4. To save changes to the policy, click Update at the bottom of the Edit Policy dialog box. After you update the policy, deleted threshold configurations are removed from BMC PATROL Agents with matching Central Monitoring Configuration tags. Recommended Thresholds Thresholds define acceptable high and/or low values for the data collected. Thresholds can be created as part of a policy that can be applied to multiple monitors types on multiple BMC PATROL Agents. The Reference Guide provides a list of monitor types with their respective attributes and, when meaningful, a recommended threshold. Using BMC ProactiveNet Performance Management This section provides a brief overview of how to navigate and use the product in the BMC ProactiveNet Operations Console. Navigating the BMC ProactiveNet Operations Console Adding attributes to the graph Viewing and manipulating attribute graphs Viewing monitors for a device Changing Thresholds For more detailed information, see BMC ProactiveNet User Guide in the PDF product guides. Configuring Thresholds 49

50 Navigating the BMC ProactiveNet Operations Console The BMC ProactiveNet Operations Console is a Web-based application that provides options to navigate through BMC ProactiveNet and view all of the information collected and computed by the BMC ProactiveNet Server related to events, views, and graphs. Navigation tree The navigation tree shows an at-a-glance synopsis of events and views. Event and component folders are displayed hierarchically and are divided into the following categories, or nodes. Object Definition Global node The Global node contains the following default collectors: All Event Collectors displays the entire event collector hierarchy All Abnormalities displays all the abnormality events All Services displays all the services All Groups displays all the groups All Devices displays all the devices Based on permissions, users can create event and component folders under this node to organize the event view. My Folder node Based on permissions, users can create event and component folders under this node to organize the event view. To further organize your display, beneath these top-level folders you can add event and component folders, including folders for Component Instances (CIs) associated with a service model. Your ability to add event and component folders depends on your permissions. The severity icons for a collector dynamically change depending on the severity level of the events for that collector. For example, if there is a Critical event on one of the devices, the green icon changes to a red icon, indicating a Critical event. The icons enable you to see the status of devices on your system immediately. For complete details, see the BMC ProactiveNet Getting Started Guide on the BMC Support website. Navigation drawers The navigation pane in the Operations Console contains a series of drawers that enable you to navigate through BMC ProactiveNet functions and views. You can select which drawers to display in the navigation pane. The following table describes the available drawers in the navigation pane and describes their functions. Using BMC ProactiveNet Performance Management 50

51 Drawer Description Main Provides access to event lists and displays event information and status. Other cells Lists available remote cells connected to the BMC ProactiveNet Server and monitored by BMC ProactiveNet. Reports Enables you to generate and manage reports based on data collected by BMC ProactiveNet. Note: You must have permission to view this drawer. Views & graphs Provides options for the management of views and graphs in the Operations Console Bookmarks Enables you to view, rename, and delete bookmarks of objects and their related views that you create in the navigation tree. Find CI Provides a search mechanism so that you can search for Component Instances that meet the specified search criteria. Note: You must have permission to view this drawer. Event and component folders Event and component folders enable you to organize cells and collectors to make event displays meaningful for operators. For example, you might create an event folder for collectors that gather database warning events and allow only operators who are database administrators access to that event folder. You can drag components from one existing folder to another within the top-level folders in the navigation tree. You also can drag and drop CIs from the Tile or Graph view to an existing folder in the All Services folder. Event folders An event folder is a grouping of collectors that shows the relationship of events or abnormalities through the hierarchy of the navigation tree. Administrators define event folders and associate them with one or more collectors. Each level of the collector is shown as a node under the event folder. An event list is associated with the lowest level nodes of an event folder. The parent level of an event folder represents all of the events or abnormalities associated with the collectors. Event collectors Event collectors gather events for display in an event list to provide operators with meaningful groups of events or abnormalities and to show relationship through the hierarchy of the nodes in the navigation tree. To access the event list for a collector, operators click the collector node in the navigation tree. Event collectors are dynamic or static. Nodes for dynamic collectors appear or disappear from the navigation tree based on whether or not events are present that meet the criteria for those collectors. Nodes for static collectors remain in the navigation tree regardless of whether events are present or not. Component folders A component folder is a grouping of groups, services, or devices from several different event lists (collectors) that shows the relationship of groups, services, or devices through the hierarchy of the navigation tree. Administrators define component folders and associate them with one or more Using BMC ProactiveNet Performance Management 51

52 groups, services, or devices. Each level of the component folder is shown as a node under the parent component folder. An event list is associated with the lowest level nodes of a component folder. The parent level of a component folder represents all of the events associated with the groups, services, or devices. Component folders are static or dynamic. You populate static component folders by selecting from a list of objects. You populate dynamic component folders by creating a query. Static folders always contain only the objects that you manually select. Dynamic folders contain the objects that match the query, so the contents of these folders can change without further editing. Operations Console views The following table shows the different views that are available, depending on what object you select in the navigation tree. Each view is accessed by clicking the associated Console view icon. If a view is not available for the object that is selected in the navigation tree, the icon for that view is not displayed in the toolbar. View Description Event The Event view displays all events in an event list. This is the default view for all objects. Use the Event view to check the details of events and to address events that highlight incorrect state. Probable Cause Analysis can help you to identify the cause of the event. An event could be assigned to other users, who can acknowledge and take ownership of the event, fix the problem, and close the event. You can also address the incorrect condition by invoking remote actions, detailed diagnostics, and local actions. The Graph view helps check the impacting service and you can cross-launch to Impact Model Designer, Service Level Manager and Product Catalog in BMC Remedy IT Service Management (BMC Remedy ITSM). You can display an Event view for: Event collectors Abnormalities Services Groups Devices Monitors Title The Canvas view enables you to create a graphical representation of the components that are being monitored in your environment. The components are represented by objects that you can place on a background image. The objects can be graphics, such as images or connectors, or metrics information represented in a tile. You can create and display a Canvas view for: Event collectors services Groups Devices Tree/Graph The Tree/Graph view displays information for a selected object as a tree that represents the hierarchy of the object. The Tree view is available for groups and services. You can use the Tree view to get a real-time, interactive visualization of the event status and other details of the selected group or service. In the Group hyperbolic tree, the entire group hierarchy and devices are visible on a hyperbolic pane that is mapped to a circular display region. Service tree is applicable only for the selected service. If a service is selected in the navigation tree, this view displays a graphical representation of the configuration items in the service model and shows how those configuration items relate to each other. Use the Graph view to monitor events for published service models that represent your business services. You can display a Tree/Graph view for: Services Using BMC ProactiveNet Performance Management 52

53 View Description Groups Grid Grid view displays information for the selected object in a tabular format. you can view the event status and other details of the selected object through hyperlinks to graphs, views, etc. You can display a Grid view for: Abnormalities Groups Devices For more detailed information, BMC ProactiveNet Getting Started Guide on the BMC Support website. Adding attributes to the graph Following configuration, only one attribute is enabled for the graph of each monitor. You might want to add additional attributes to the monitor graph. 1. In the BMC ProactiveNet Operations console, select the Navigation drawer. 2. Select Global > Devices. 3. Select the Grid view. All the monitored devices are displayed in table format. 4. Select a device from the displayed table. 5. Select a monitor. 6. Click Tools >Show Graph 7. Select the Attributes & Indicators tab. 8. Select one or more attributes. Up to 12 attributes of a monitor can be displayed on a single graph. Though only two units of measurement can be used. Viewing and manipulating attribute graphs The graph provides a visual display of the attributes of a monitor. Up to 12 attributes of a monitor can be displayed on a single graph In the BMC ProactiveNet Operations console, select the Navigation drawer. Select Global > Devices. Select the Grid view. All the monitored devices are displayed in table format. Select a device from the table. Select a monitor. Click Tools > Show Graph If Collect Data is not enabled then no data is available. The Graph Display window opens, displaying a graph displaying the values of the selected attributes for this monitor. You can use the options available on this tab to manipulate the graph. For complete details, refer to BMC ProactiveNet User Guide on the BMC Support website. Using BMC ProactiveNet Performance Management 53

54 Viewing monitors for a device This section provides a brief overview of how to view the monitors for a selected device. For complete details, refer to BMC ProactiveNet User Guide on the BMC Support website. To view the Monitor types for a device In the BMC ProactiveNet Operations console, select the Navigation drawer. Select Global > Devices. Select the Grid view. All the monitored devices are displayed in table format. Select a device from the table. A hierarchical tree listing the monitors for that device is displayed. You can click the + and - to expand and collapse nodes of the hierarchical tree. The following information is displayed: Information Description Monitor Name Device name or process name, a device might appear more than once if it is monitored by several PATROL Agents Monitor Type Name of the monitor type. This will correspond to the element displayed in the Monitor Name column, specifying the type of device or process monitored Source Agent ProactiveNet server where the PATROL Agent and integration service are running Open Number of open alerts, a green globe is displayed if no alerts are open Closed Number of closed alerts Enabled Enabled if data is being collected Changing thresholds You can adjust the thresholds for the attributes of a monitor type either globally or for a specific device instance. In the BMC ProactiveNet Operations console, select the Navigation drawer Select Select Select Select Select Global > Devices. the Grid view. All the monitored devices are displayed in table format. a device from the table. a monitor. Tools > Thresholds. A menu containing the available thresholds is displayed. Global thresholds are applied to all monitor instances of the selected monitor type. Instance thresholds are applied to the selected monitor instance. 6. Edit the Threshold settings 7. Click Apply. Using BMC ProactiveNet Performance Management 54

55 Managing Baselines and Key Performance Indicators In order to facilitate the detection of abnormalities on your monitored environment, BMC ProactiveNet calculates baselines per attributes based on values collected over a specified period of time to determine a normal operating range. When the collected values for these attributes are out of range, an alert is triggered. Some attributes are identified by default as Key Performance Indicators and therefore automatically included in the base lining calculation. Managing baselines The baseline is the expected normal operating range for a metric or attribute of a monitor. The baseline is calculated by collecting the values for a monitor s attributes and metrics over a specified time period and establishing a low baseline value (consisting of the 10th percentile of all the values for a given time period) and a high baseline value (consisting of the 90th percentile of all the values for a given time period), taking a weighted average of these values over time. A higher weight is given to the latest data being factored into the baseline average. The accuracy of the baseline improves over time. Requirements for baseline generation For baselines to be generated for an attribute, that abnormality threshold means that the threshold exists and is not suppressed. Additionally, if the Key Performance Indicator (KPI) mode is active, only those attributes that have an active abnormality threshold and are also KPI attributes will have baselines generated for them. Absolute thresholds (w ith "outside baseline") or signature thresholds do not satisfy these requirements. Managing Key Performance Indicators The KPI attribute of an attribute can be activated or deactivated manually through the BMC ProactiveNet Administration Console. In this KM, some attributes have been designated as important indicators of performance (KPIs). We do not recommend that these default settings are modified. However, advanced users may activate or deactivate KPIs from the BMC ProactiveNet Administration Console. Using BMC ProactiveNet Performance Management 55

56 To add or remove Key Performance Indicator (KPI) attributes for a monitor type 1. In the Administration Console, from the menu bar, choose Tools > KPI Administration. The KPI Administration dialog box is displayed. 2. From the Monitor Type list, choose the monitor type for which you want to add or remove KPI attributes. A list of attributes for the selected monitor type is displayed. 3. In the KPI column for the attributes that you want to add or remove as Key Performance Indicators: select the KPI check box to add the corresponding attribute as a KPI deselect the KPI check box to remove the corresponding attribute from the KPIs for that monitor type For complete and detailed information on this procedure, please refer to the BMC ProactiveNet documentation available from BMC W eb site. Attributes considered as KPIs are respectively identified by the following icon:. Using BMC ProactiveNet Performance Management 56

57 Reference Guide

58 Introduction This chapter provides statistical information about resources, operating status, and performances managed by the Veritas Cluster Server KM. It contains tables describing the attributes used in the KM, grouped by Monitor Types, and provides a brief description of each attribute and its default settings. Monitor Types Veritas Cluster Server KM VCS Agent VCS Daemon VCS GAB VCS GAB Port VCS Group System VCS LLT VCS LLT Interface VCS Log VCS Resource VCS Resource System VCS Service Group VCS System VCS System Heartbeat VCS WAN Heartbeat Baselines and Key Performance Indicators Some attributes are identified by default as Key Performance Indicators (KPIs) and therefore automatically included in the base lining calculation. To learn more about auto baselining and KPIs, please refer to the Managing Baselines and Key Performance Indicators chapter. In this guide, attributes flagged as KPIs are respectively identified by the following icon: 58.

59 Veritas Cluster Server KM Attributes Name Description Units Recommended Alert Conditions BMC ProactiveNet Attribute Type Login Status Monitors the status of the VCS KM login details (username/password) for the operating system. 0 = Ok 1 = Suspicious 2 = Failure Warning = 1 Alarm = 2 Collection Status Monitoring Mode Indicates the VCS monitoring mode. 0 = Permanent Single-node Mode 1 = Temporary Single-node Mode 2 = Active Multi-node Mode 3 = Passive Multi-node Mode -1 = Unknown Collection Status Node Status Monitors error messages for the Veritas Cluster Server application on this managed system. It is set by VCS_SERVER application class discovery. If any of the Veritas Cluster Server application daemons is not running, this parameter will be set to "Failure" state. The list of critical Veritas Cluster Server daemons can be customized using the KM command Configuration > Node Status from the Veritas Cluster Server icon. If there are any suspicious command exits due to an error, this parameter will be set to "Suspicious" state. If this status parameter changes to warning or alarm state, the recovery action will trigger an event and annotate the last data point. 0 = Ok 1 = Suspicious 2 = Failure Warning = 1 Alarm = 2 Availability 59

60 VCS Agent Attributes Name Description Units Recommended Alert Conditions BMC ProactiveNet Attribute Type Fault Count Displays the number of the agent faults as reported in the command executed by the data collector. Count n/a Statistics State Displays the state of the agent as reported in the command executed by the data collector. 0 = Running 1 = Not Started 2 = Not Running -1 = Unknown Availability Status Monitors the status of the agent.the following State to Status mapping rule is used: Not Running > Failure Unknown > Failure All other states > OK 0 = Ok 1 = Suspicious 2 = Failure Warning = 1 Alarm = 2 Availability For detailed information about KPI, see Managing Baselines and Key Performance Indicators. VCS Daemon Attributes Name Description Units Recommended Alert Conditions BMC ProactiveNet Attribute Type CPU Duration Indicates the CPU seconds consumed by the daemon. seconds Statistics CPU Utilization Indicates the CPU seconds consumed by the daemon. % Statistics Memory Size Indicates the core image size of the daemon in the virtual memory. KB Statistics Processes Count Indicates the number of the processes/threads of the daemon found. processes Statistics VCS Agent 60

61 State Indicates the state of the daemon as reported in the command executed by the data collector. 0 = Running 1 = Sleeping 2 = Waiting 3 = Queued 4= Intermediate 5= Terminated 6 = Stopped/ Disabled 7 = Growing 8= xistent/ Not Responding 9 = Not Running -1 = Unknown Availability Status Monitors the status of the daemon. The following State to Status mapping rule is used: Not Running > Failure Terminated, Stopped > Suspicious Growing, or Unknown > Suspicious All other states > OK 0 = Ok 1 = Suspicious 2 = Failure Warning = 1 Alarm = 2 Availability For detailed information about KPI, see Managing Baselines and Key Performance Indicators. VCS GAB Attributes Name Description Units Recommended Alert Conditions BMC ProactiveNet Attribute Type Node Count This parameter displays the number of nodes. Count Statistics Status This parameter monitors the status of the GAB module. If the GAB module is not configured or in jeopardy, this parameter will be set to "Failure". 0 = Ok 1 = Suspicious 2 = Failure Warning = 1 Alarm = 2 n/a For detailed information about VCS Daemon KPI, see Managing Baselines and Key Performance Indicators. 61

62 VCS GAB Port Attributes Name Description Units Recommended Alert Conditions BMC ProactiveNet Attribute Type State This parameter displays the state of the GAB as reported in the command executed by the data collector. 0= Membership 1 = Waiting for Seed 2 = Jeopardy -1 = Unknown Availability Status This parameter monitors the status of the GAB. 0 = Ok 1 = Suspicious 2 = Failure Warning = 1 Alarm = 2 Availability The following State to Status mapping rule is used: Waiting for Seed > Suspicious Jeopardy > Failure Unknown > Failure All other states > OK VCS Group System Attributes Name Description Units Recommended Alert Conditions BMC ProactiveNet Attribute Type Auto Disabled This parameter indicates whether the service group has been auto-disabled on the system by Veritas Cluster Server. 0 = No 1 = Yes -1 = Unknown Alarm = 1 Availability Enabled This parameter indicates whether the service group has been enabled on the system. 0 = No 1 = Yes -1 = Unknown Warning = 0 Availability Pending Probe Count This parameter displays the number of pending probes for this group system. Count Warning if out of [0-100] Statistics range Warning: Probed This parameter indicates whether the service group has been successfully probed on the system. 0 = No 1 = Yes -1 = Unknown Warning = 0 VCS GAB 62 Collection Status

63 State This parameter displays the state of the group system as reported in the command executed by the data collector. Note: ONLINE* and OFFLINE* states represent all other ONLINE and OFFLINE states with a secondary state respectively. 0 = ONLINE 1 = ONLINE* 2 = OFFLINE 3 = OFFLINE* 4 = STARTING 5 = STOPPING 6 = PARTIAL 7 = FAULTED -1 = UNKNOWN Status This parameter monitors the status of the group system. The following State to Status mapping rule is used: ONLINE* or OFFLINE > Suspicious STARTING or STOPPING > Suspicious PARTIAL or FAULTED > Failure Unknown > Failure All other states > OK 0 = Ok 1 = Suspicious 2 = Failure For detailed information about Warning = 1 Alarm = 2 Availability Availability KPI, see Managing Baselines and Key Performance Indicators. VCS LLT Attributes Name Description Link Count Recommended Alert Conditions BMC ProactiveNet Attribute Type This parameter displays the Count number of links active in the LLT communication. Statistics Receive Packet Rate This parameter displays the packets/second number of received packets per second in the LLT communication. Statistics Received Not Connected Packets Count This parameter displays the Packets number of non-connected received packets in the LLT communication. Statistics Received Packet Count This parameter displays the Packets number of received packets in the LLT communication. Statistics Send Packet Rate This parameter displays the packets/second number of sent packets per second in the LLT communication. Statistics VCS Group System Units 63

64 Sent Connected Packet Count This parameter displays the packets number of sent connected packets in the LLT communication. Statistics Sent Not Connected Packet Count This parameter displays the Count number of non-connected received packets in the LLT communication. Statistics Sent Packet Count This parameter displays the Packets number of sent packets in the LLT communication. Statistics Status This parameter monitors the status of the LLT module. If the LLT module is not running, this parameter will be set to "Failure". Warning = 1 Alarm = 2 Statistics For detailed information about 0 = Ok 1 = Suspicious 2 = Failure KPI, see Managing Baselines and Key Performance Indicators. VCS LLT Interface Attributes Name Description Units Recommended Alert BMC ProactiveNet Conditions Attribute Type State This parameter displays the state of the LLT as reported in the command executed by the data collector. 0 = Down 1 = Up -1 = Unknown Availability Status This parameter monitors the status of the LLT.The following State to Status mapping rule is used: Down > Failure Unknown > Failure All other states > OK 0 = Ok 1= Suspicious 2 = Failure Warning = 1 Alarm = 2 Availability VCS LOG Attributes VCS LLT Name Description Units Recommended Alert Conditions BMC ProactiveNet Attribute Type Alarm Message Count This parameter monitors the number of alarm messages. Count Alarm if out of [0-100] range Alarm: Statistics 64

65 File Space Growth Rate This parameter displays the growth rate of the amount of space used by the log file. KB/s Statistics File Space Used This parameter displays the amount of space used by the log file. KB Statistics Filesystem Space Used Percent This parameter monitors the percentage of capacity used by the log file. Percent (%) Alarm if out of [0-100] range Warning: Alarm: Statistics Space Available This parameter monitors the available space for the log file to use (this is also the available space on the file system). MB Warning = 2-5 Alarm = -1 to 2 Availability Space Used Percent This parameter monitors the percentage of space used by the file system (where the log file resides). Percent (%) Alarm if out of [0-100] range Warning: Alarm: Statistics Warning Message Count This parameter monitors the number warning messages. Count Alarm if out of [0-100] range Warning: Statistics For detailed information about KPI, see Managing Baselines and Key Performance Indicators. VCS Resource Attributes Name Description Units Recommended Alert Conditions BMC ProactiveNet Attribute Type Failover Status This parameter monitors the failover status of the resource. If the VCS system(s) where this resource is ONLINE differs between the current and previous collection cycles, this parameter will be set to "Suspicious". If there is no ONLINE system found for this resource, it will be set to "Failure". 0 = Ok 1 = Suspicious 2 = Failure Warning = 1 Alarm = 2 Availability Fault SystemCount This parameter displays the number of systems where this resource is in FAULTED state. Count Warning if out of [0-100] Statistics range Warning: VCS LOG 65

66 Offline System Count This parameter displays the number of systems where this resource is in OFFLINE state. Count Statistics Online System Count This parameter displays the number of systems where this resource is in ONLINE state. Count Statistics Partial System Count This parameter, set by VCSResourceCollector, displays the number of systems where this resource is in PARTIAL state. Count Statistics State This parameter displays the state of the resource as reported in the command executed by the data collector. 0 = Enabled 1 = Disabled 2 = Disabled / Critical -1 = Unknwon Availability Status This parameter monitors the status of the resource. 0 = Ok 1 = Suspicious 2 = Failure Warning = 1 Alarm = 2 Availability For detailed information about KPI, see Managing Baselines and Key Performance Indicators. VCS Resource System Attributes Name Description Units Recommended Alert Conditions BMC ProactiveNet Attribute Type Probed This parameter indicates whether the resource has been successfully probed on the system. 0 = No 1 = Yes -1 = Unknown Warning = 0 Availability State This parameter displays the state of the resource system as reported in the command executed by the data collector. 0 = ONLINE 1 = ONLINE* 2 = OFFLINE 3 = OFFLINE* 4 = STARTING 5 = STOPPING 6 = PARTIAL 7 = FAULTED -1 = UNKNOWN Availability Status This parameter monitors 0 = Ok the status of the resource 1 = Suspicious system. 2 = Failure The following State to Status mapping rule is used: ONLINE* or OFFLINE* > Suspicious STARTING or STOPPING > Suspicious Warning = 1 Alarm = 2 Availability VCS Resource 66

67 PARTIAL or FAULTED > Failure Unknown > Failure All other states > OK VCS Service Group Attributes Name Description Units Recommended Alert Conditions BMC ProactiveNet Attribute Type Failover Status This parameter monitors the failover status of the group. If the VCS system(s) where this service group is ONLINE differs between the current and previous collection cycles, this parameter will be set to "Suspicious" state. If there is no ONLINE system found for this service group, it will be set to "Failure". 0 = Ok 1 = Suspicious 2 = Failure Warning = 1 Alarm = 2 Availability Fault System Count This parameter displays the number of systems where this service group is in FAULTED state. Count Warning if out of [0100] range Warning: Statistics Frozen State This parameter displays the frozen state of the group as reported in the command executed by the data collector. 0 = Not Frozen 1 = TFrozen 2 = Frozen -1 = Unknown Availability Frozen Status This parameter monitors the frozen status of the group. TFrozen > Suspicious Frozen > Failure Unknown > Failure All other states > OK 0 = Ok 1 = Suspicious 2 = Failure Warning = 1 Alarm = 2 Availability Offline System Count This parameter displays the number of systems where this service group is in OFFLINE state. Count Statistics Online System Count This parameter displays the number of systems where this service group is in ONLINE state. Count Alarm 0 Statistics Partial System Count This parameter displays the number of systems where this service group is in PARTIAL state. Count Statistics For detailed information about VCS Resource System KPI, see Managing Baselines and Key Performance Indicators. 67

68 VCS System Attributes Name Description Units Recommended Alert Conditions BMC ProactiveNet Attribute Type CPU Available Percent This parameter monitors the percentage of available CPU on the system. Percent (%) Warning = 5-10 Alarm: 0-5 Statistics CPU Used Percent This parameter displays the percentage of CPU used by the system. Percent (%) Statistics Load Warning Duration This parameter indicates how long the system load has been over the warning threshold set in Veritas Cluster Server with the LoadTimeCounter system attribute. Seconds Statistics System Frozen State This parameter displays the frozen state of the system as reported in the command executed by the data collector. 0 = Not Frozen 1 = TFrozen 2 = Frozen -1 = Unknown Availability System Frozen Status This parameter monitors the frozen status of the system. The following State to Status mapping rule is used: TFrozen > Suspicious Frozen > Failure Unknown > Failure All other states > OK 0 = Ok 1 = Suspicious 2 = Failure Warning = 1 Alarm = 2 Availability Online Group Count This parameter displays the number of groups that are online or about to go online on a system, as reported in the command executed by the data collector. Count Statistics System State This parameter displays the state of the resource system as reported in the command executed by the data collector. 0 = INITING Availability VCS System 68

69 1= CURRENT_DIS COVER_WAIT 2= CURRENT_PEE R_WAIT 3= STALE_DISCO VER_WAIT 4= STALE_PEER_ WAIT 5= LOCAL_BUILD 6= REMOTE_BUIL D 7 = RUNNING 8= ADMIN_WAIT 9= STALE_ADMIN _WAIT 10 = LEAVING 11 = EXITING 12 = EXITING_FOR CIBLY 13 = EXITED 14 = FAULTED -1 = UNKNOWN System Status This parameter monitors 0 = Ok the status of the system. 1 = Suspicious The following State to 2 = Failure Status mapping rule is used: CURRENT_DISCOVER_ WAIT, CURRENT_PEER_WAIT, STALE_DISCOVER_WAI T, STALE_PEER_WAIT, LOCAL_BUILD, or REMOTE_BUILD for more than 10 minutes > Suspicious ADMIN_WAIT, STALE_ADMIN_WAIT, LEAVING, EXITING, EXITING_FORCIBLY, or EXITED > Suspicious FAULTED, or UNKNOWN > Failure All other states > OK Warning = 1 Alarm = 2 Availability Stopped Agent Count This parameter displays the number of stopped agents on the system. Count Statistics System Up Down State This parameter displays the up/down state of the system as reported in the command executed by the data collector. 0 = Down 1 = Up -1 = Unknown Availability VCS System 69

70 System Up Down Status This parameter monitors the up/down status of the system. The following State to Status mapping rule is used: Down > Failure Unknown > Failure All other states > OK For detailed information about 0 = Ok 1 = Suspicious 2 = Failure Warning = 1 Alarm = 2 Availability KPI, see Managing Baselines and Key Performance Indicators. VCS System Heartbeat Attributes Name Description Units Recommended Alert Conditions BMC ProactiveNet Attribute Type State This parameter displays the state of the heartbeat as reported in the command executed by the data collector. 0 = Down 1 = Up -1 = Unknown Availability Status This parameter monitors the status of the heartbeat. 0 = Ok 1 = Suspicious 2 = Failure Warning = 1 Alarm = 2 Availability VCS WAN Heartbeat Attributes Name Description Units Recommended Alert Conditions BMC ProactiveNet Attribute Type State This parameter displays the state of the WAN heartbeat as reported in the command executed by the data collector. 0 = Dead 1 = Alive -1 = Unknown Availability Status This parameter monitors the status of the WAN heartbeat. 0 = Ok 1 = Suspicious 2 = Failure Warning = 1 Alarm = 2 Availability VCS System 70

71 About BMC Software BMC Software, Inc. NYSE:BMC, is a leading provider of enterprise management solutions that empower companies to manage their IT infrastructure from a business perspective. Delivering Business Service Management, BMC Software solutions span enterprise systems, applications, databases, and service management. Founded in 1980, BMC Software has offices worldwide and fiscal 2004 revenues of more than $1.4 billion. For more information about BMC Software, visit About Sentry Software Sentry Software, a strategic Technology Alliance Partner of BMC Software, provides key monitoring solutions specifically designed to expand the capabilities of BMC Performance Manager, thus enabling up to 100% coverage of any infrastructure. Sentry Software specializes in single solutions for multi-platform monitoring of hardware, custom applications or any IT component, and blackout windows. Sentry Software products are deployed in 45 countries across the globe and lead the list of BMC Software s third-party product sales. For more information about Sentry Software, please visit

BMC ProactiveNet Performance Management - Veritas Cluster Server Monitoring

BMC ProactiveNet Performance Management - Veritas Cluster Server Monitoring USER DOCUMENTATION HIGH AVAILABILITY MONITORING BMC ProactiveNet Performance Management - Veritas Cluster Server Monitoring Version 2.5.01 September 2015 Contacting BMC Software You can access the BMC

More information

BMC ProactiveNet Performance Management - Veritas File System Monitoring

BMC ProactiveNet Performance Management - Veritas File System Monitoring BMC ProactiveNet Performance Management - Veritas File System Monitoring User Documentation January 2013 Contacting BMC Software You can access the BMC Software Web site at http://www.bmc.com/. From this

More information

TrueSight Operations Management Monitoring Studio

TrueSight Operations Management Monitoring Studio USER DOCUMENTATION APPLICATIONS MONITORING TrueSight Operations Management Monitoring Studio Version 9.0.00 June 2015 Contacting BMC Software You can access the BMC Software Web site at http://www.bmc.com.

More information

BMC ProactiveNet Performance Management EMC NetWorker Monitoring

BMC ProactiveNet Performance Management EMC NetWorker Monitoring BMC ProactiveNet Performance Management EMC NetWorker Monitoring User Documentation January 2013 Table of Contents User Goals and Features...5 Business Value...5 Requirements...5 System Requirements...6

More information

White Paper BMC Remedy Action Request System Security

White Paper BMC Remedy Action Request System Security White Paper BMC Remedy Action Request System Security June 2008 www.bmc.com Contacting BMC Software You can access the BMC Software website at http://www.bmc.com. From this website, you can obtain information

More information

PATROL Console Server and RTserver Getting Started

PATROL Console Server and RTserver Getting Started PATROL Console Server and RTserver Getting Started Supporting PATROL Console Server 7.5.00 RTserver 6.6.00 February 14, 2005 Contacting BMC Software You can access the BMC Software website at http://www.bmc.com.

More information

IBM WebSphere Application Server Version 7.0

IBM WebSphere Application Server Version 7.0 IBM WebSphere Application Server Version 7.0 Centralized Installation Manager for IBM WebSphere Application Server Network Deployment Version 7.0 Note: Before using this information, be sure to read the

More information

BMC FootPrints Asset Core - Asset Discovery. Version 11.7

BMC FootPrints Asset Core - Asset Discovery. Version 11.7 BMC FootPrints Asset Core - Asset Discovery Version 11.7 Legal Notices Copyright 1999, 2009 BMC Software, Inc. Copyright 1994-2013 Numara Software, Inc. BMC, BMC Software, and the BMC Software logo are

More information

BMC Impact Solutions Infrastructure Management Guide

BMC Impact Solutions Infrastructure Management Guide BMC Impact Solutions Infrastructure Management Guide Supporting BMC Impact Manager version 7.3 BMC Impact Administration Server 7.3 BMC Impact Explorer version 7.3 BMC Impact Portal version 7.3 February

More information

BMC Service Request Management 7.6.04 User s Guide

BMC Service Request Management 7.6.04 User s Guide BMC Service Request Management 7.6.04 User s Guide January 2011 www.bmc.com Contacting BMC Software You can access the BMC Software website at http://www.bmc.com. From this website, you can obtain information

More information

BMC Performance Manager Portal Monitoring and Management Guide

BMC Performance Manager Portal Monitoring and Management Guide BMC Performance Manager Portal Monitoring and Management Guide Supporting BMC Performance Manager Portal 2.7 Remote Service Monitor 2.7 April 2009 www.bmc.com Contacting BMC Software You can access the

More information

Control-M for Hadoop. Technical Bulletin. www.bmc.com

Control-M for Hadoop. Technical Bulletin. www.bmc.com Technical Bulletin Control-M for Hadoop Version 8.0.00 September 30, 2014 Tracking number: PACBD.8.0.00.004 BMC Software is announcing that Control-M for Hadoop now supports the following: Secured Hadoop

More information

WHITE PAPER. Best Practices for Configuring PATROL for Microsoft Exchange Servers

WHITE PAPER. Best Practices for Configuring PATROL for Microsoft Exchange Servers WHITE PAPER Best Practices for Configuring PATROL for Microsoft Exchange Servers Contents INTRODUCTION..................................................... 3 PATROL SECURITY....................................................

More information

BMC Client Management - Client Agent Rollout. Version 12.0

BMC Client Management - Client Agent Rollout. Version 12.0 BMC Client Management - Client Agent Rollout Version 12.0 Legal Notices Copyright 1999, 2009 BMC Software, Inc. Copyright 1994-2014 Numara Software, Inc. BMC, BMC Software, and the BMC Software logo are

More information

BMC BladeLogic Client Automation Installation Guide

BMC BladeLogic Client Automation Installation Guide BMC BladeLogic Client Automation Installation Guide Supporting BMC BladeLogic Client Automation 8.2.02 January 2013 www.bmc.com Contacting BMC Software You can access the BMC Software website at http://www.bmc.com.

More information

Online Backup Client User Manual Linux

Online Backup Client User Manual Linux Online Backup Client User Manual Linux 1. Product Information Product: Online Backup Client for Linux Version: 4.1.7 1.1 System Requirements Operating System Linux (RedHat, SuSE, Debian and Debian based

More information

Embarcadero Performance Center 2.7 Installation Guide

Embarcadero Performance Center 2.7 Installation Guide Embarcadero Performance Center 2.7 Installation Guide Copyright 1994-2009 Embarcadero Technologies, Inc. Embarcadero Technologies, Inc. 100 California Street, 12th Floor San Francisco, CA 94111 U.S.A.

More information

CA Spectrum and CA Service Desk

CA Spectrum and CA Service Desk CA Spectrum and CA Service Desk Integration Guide CA Spectrum 9.4 / CA Service Desk r12 and later This Documentation, which includes embedded help systems and electronically distributed materials, (hereinafter

More information

Veritas Cluster Server Database Agent for Microsoft SQL Configuration Guide

Veritas Cluster Server Database Agent for Microsoft SQL Configuration Guide Veritas Cluster Server Database Agent for Microsoft SQL Configuration Guide Windows 2000, Windows Server 2003 5.0 11293743 Veritas Cluster Server Database Agent for Microsoft SQL Configuration Guide Copyright

More information

WebSphere Business Monitor V7.0: Clustering Single cluster deployment environment pattern

WebSphere Business Monitor V7.0: Clustering Single cluster deployment environment pattern Copyright IBM Corporation 2010 All rights reserved WebSphere Business Monitor V7.0: Clustering Single cluster deployment environment pattern What this exercise is about... 2 Exercise requirements... 2

More information

PN 00651. Connect:Enterprise Secure FTP Client Release Notes Version 1.2.00

PN 00651. Connect:Enterprise Secure FTP Client Release Notes Version 1.2.00 PN 00651 Connect:Enterprise Secure FTP Client Release Notes Version 1.2.00 Connect:Enterprise Secure FTP Client Release Notes Version 1.2.00 First Edition This documentation was prepared to assist licensed

More information

Synthetic Monitoring Scripting Framework. User Guide

Synthetic Monitoring Scripting Framework. User Guide Synthetic Monitoring Scripting Framework User Guide Please direct questions about {Compuware Product} or comments on this document to: APM Customer Support FrontLine Support Login Page: http://go.compuware.com

More information

This document contains the following topics:

This document contains the following topics: Release Notification BMC Discovery Solution Version 8.1.00 December 18, 2009 This document describes the products and components contained in version 8.1.00 of BMC Discovery Solution. If you have any questions,

More information

How To Install An Aneka Cloud On A Windows 7 Computer (For Free)

How To Install An Aneka Cloud On A Windows 7 Computer (For Free) MANJRASOFT PTY LTD Aneka 3.0 Manjrasoft 5/13/2013 This document describes in detail the steps involved in installing and configuring an Aneka Cloud. It covers the prerequisites for the installation, the

More information

1. Product Information

1. Product Information ORIXCLOUD BACKUP CLIENT USER MANUAL LINUX 1. Product Information Product: Orixcloud Backup Client for Linux Version: 4.1.7 1.1 System Requirements Linux (RedHat, SuSE, Debian and Debian based systems such

More information

Veritas Cluster Server Database Agent for Microsoft SQL Configuration Guide

Veritas Cluster Server Database Agent for Microsoft SQL Configuration Guide Veritas Cluster Server Database Agent for Microsoft SQL Configuration Guide Windows Server 2003, Windows Server 2008 5.1 Veritas Cluster Server Database Agent for Microsoft SQL Configuration Guide Copyright

More information

CA Nimsoft Monitor. Probe Guide for E2E Application Response Monitoring. e2e_appmon v2.2 series

CA Nimsoft Monitor. Probe Guide for E2E Application Response Monitoring. e2e_appmon v2.2 series CA Nimsoft Monitor Probe Guide for E2E Application Response Monitoring e2e_appmon v2.2 series Copyright Notice This online help system (the "System") is for your informational purposes only and is subject

More information

BMC ProactiveNet Performance Management - Tivoli Storage Manager Monitoring Version 2.7.01. User Documentation

BMC ProactiveNet Performance Management - Tivoli Storage Manager Monitoring Version 2.7.01. User Documentation BMC ProactiveNet Performance Management - Tivoli Storage Manager Monitoring User Documentation October 2013 Table of Contents User Goals and Features...11 Business Value...11 Requirements...12...12 System

More information

CA SiteMinder. Web Agent Installation Guide for IIS 12.51

CA SiteMinder. Web Agent Installation Guide for IIS 12.51 CA SiteMinder Web Agent Installation Guide for IIS 12.51 This Documentation, which includes embedded help systems and electronically distributed materials (hereinafter referred to as the Documentation

More information

RecoveryVault Express Client User Manual

RecoveryVault Express Client User Manual For Linux distributions Software version 4.1.7 Version 2.0 Disclaimer This document is compiled with the greatest possible care. However, errors might have been introduced caused by human mistakes or by

More information

Application Servers - BEA WebLogic. Installing the Application Server

Application Servers - BEA WebLogic. Installing the Application Server Proven Practice Application Servers - BEA WebLogic. Installing the Application Server Product(s): IBM Cognos 8.4, BEA WebLogic Server Area of Interest: Infrastructure DOC ID: AS01 Version 8.4.0.0 Application

More information

CA Nimsoft Monitor Snap

CA Nimsoft Monitor Snap CA Nimsoft Monitor Snap Configuration Guide for IIS Server Monitoring iis v1.5 series Legal Notices This online help system (the "System") is for your informational purposes only and is subject to change

More information

CA ARCserve Backup for Windows

CA ARCserve Backup for Windows CA ARCserve Backup for Windows Agent for Microsoft SharePoint Server Guide r15 This documentation and any related computer software help programs (hereinafter referred to as the "Documentation") are for

More information

WebSphere Business Monitor V7.0 Installation and stand-alone server profile creation

WebSphere Business Monitor V7.0 Installation and stand-alone server profile creation Copyright IBM Corporation 2010 All rights reserved WebSphere Business Monitor V7.0 Installation and stand-alone server profile creation What this exercise is about... 2 Exercise requirements... 2 What

More information

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream User Manual Onsight Management Suite Version 5.1 Another Innovation by Librestream Doc #: 400075-06 May 2012 Information in this document is subject to change without notice. Reproduction in any manner

More information

Online Backup Client User Manual

Online Backup Client User Manual For Linux distributions Software version 4.1.7 Version 2.0 Disclaimer This document is compiled with the greatest possible care. However, errors might have been introduced caused by human mistakes or by

More information

Attix5 Pro Server Edition

Attix5 Pro Server Edition Attix5 Pro Server Edition V7.0.3 User Manual for Linux and Unix operating systems Your guide to protecting data with Attix5 Pro Server Edition. Copyright notice and proprietary information All rights reserved.

More information

Integration for BMC Remedy Service Desk

Integration for BMC Remedy Service Desk Integration for BMC Remedy Service Desk User Guide Supporting Integration for BMC Remedy Service Desk 7.3.01 BMC Impact Manager 7.3.01 BMC Remedy Service Desk 7.3.01 BMC ProactiveNet Performance Management

More information

Online Backup Client User Manual Mac OS

Online Backup Client User Manual Mac OS Online Backup Client User Manual Mac OS 1. Product Information Product: Online Backup Client for Mac OS X Version: 4.1.7 1.1 System Requirements Operating System Mac OS X Leopard (10.5.0 and higher) (PPC

More information

Online Backup Client User Manual Mac OS

Online Backup Client User Manual Mac OS Online Backup Client User Manual Mac OS 1. Product Information Product: Online Backup Client for Mac OS X Version: 4.1.7 1.1 System Requirements Operating System Mac OS X Leopard (10.5.0 and higher) (PPC

More information

Knowledge Article Performance Comparison: BMC Remedy ITSM Incident Management version 7.5.00 Vs. 7.0.03 on Windows

Knowledge Article Performance Comparison: BMC Remedy ITSM Incident Management version 7.5.00 Vs. 7.0.03 on Windows Knowledge Article Performance Comparison: BMC Remedy ITSM Incident Management version 7.5.00 Vs. 7.0.03 on Windows April 2009 www.bmc.com Contacting BMC Software You can access the BMC Software website

More information

CA SiteMinder. Web Agent Installation Guide for IIS. r12.5

CA SiteMinder. Web Agent Installation Guide for IIS. r12.5 CA SiteMinder Web Agent Installation Guide for IIS r12.5 This Documentation, which includes embedded help systems and electronically distributed materials, (hereinafter referred to as the Documentation

More information

BMC Remedy IT Service Management Suite 7.6.04 Installing and Configuring Server Groups

BMC Remedy IT Service Management Suite 7.6.04 Installing and Configuring Server Groups BMC Remedy IT Service Management Suite 7.6.04 Installing and Configuring Server Groups January 2011 www.bmc.com Contacting BMC Software You can access the BMC Software website at http://www.bmc.com. From

More information

HP Enterprise Integration module for SAP applications

HP Enterprise Integration module for SAP applications HP Enterprise Integration module for SAP applications Software Version: 2.50 User Guide Document Release Date: May 2009 Software Release Date: May 2009 Legal Notices Warranty The only warranties for HP

More information

TIBCO ActiveMatrix BusinessWorks Plug-in for TIBCO Managed File Transfer Software Installation

TIBCO ActiveMatrix BusinessWorks Plug-in for TIBCO Managed File Transfer Software Installation TIBCO ActiveMatrix BusinessWorks Plug-in for TIBCO Managed File Transfer Software Installation Software Release 6.0 November 2015 Two-Second Advantage 2 Important Information SOME TIBCO SOFTWARE EMBEDS

More information

Online Backup Linux Client User Manual

Online Backup Linux Client User Manual Online Backup Linux Client User Manual Software version 4.0.x For Linux distributions August 2011 Version 1.0 Disclaimer This document is compiled with the greatest possible care. However, errors might

More information

Administration Quick Start

Administration Quick Start www.novell.com/documentation Administration Quick Start ZENworks 11 Support Pack 3 February 2014 Legal Notices Novell, Inc., makes no representations or warranties with respect to the contents or use of

More information

CONTROL-M/Enterprise Manager API Developer Guide

CONTROL-M/Enterprise Manager API Developer Guide CONTROL-M/Enterprise Manager API Developer Guide Supporting CONTROL-M/Enterprise Manager version 6.4.01 September 2008 www.bmc.com Contacting BMC Software You can access the BMC Software website at http://www.bmc.com.

More information

CA Unified Infrastructure Management Server

CA Unified Infrastructure Management Server CA Unified Infrastructure Management Server CA UIM Server Configuration Guide 8.0 Document Revision History Version Date Changes 8.0 September 2014 Rebranded for UIM 8.0. 7.6 June 2014 No revisions for

More information

Veritas Operations Manager Release Notes. 3.0 Rolling Patch 1

Veritas Operations Manager Release Notes. 3.0 Rolling Patch 1 Veritas Operations Manager Release Notes 3.0 Rolling Patch 1 Veritas Operations Manager Release Notes The software described in this book is furnished under a license agreement and may be used only in

More information

Oracle Enterprise Manager. Description. Versions Supported

Oracle Enterprise Manager. Description. Versions Supported Oracle Enterprise Manager System Monitoring Plug-in Installation Guide for Microsoft SQL Server Release 10 (4.0.3.1.0) E14811-03 June 2009 This document provides a brief description about the Oracle System

More information

Implementing a SAS 9.3 Enterprise BI Server Deployment TS-811. in Microsoft Windows Operating Environments

Implementing a SAS 9.3 Enterprise BI Server Deployment TS-811. in Microsoft Windows Operating Environments Implementing a SAS 9.3 Enterprise BI Server Deployment TS-811 in Microsoft Windows Operating Environments Table of Contents Introduction... 1 Step 1: Create a SAS Software Depot..... 1 Step 2: Prepare

More information

CA Nimsoft Monitor. Probe Guide for IIS Server Monitoring. iis v1.5 series

CA Nimsoft Monitor. Probe Guide for IIS Server Monitoring. iis v1.5 series CA Nimsoft Monitor Probe Guide for IIS Server Monitoring iis v1.5 series Legal Notices Copyright 2013, CA. All rights reserved. Warranty The material contained in this document is provided "as is," and

More information

How To Install Caarcserve Backup Patch Manager 27.3.2.2 (Carcserver) On A Pc Or Mac Or Mac (Or Mac)

How To Install Caarcserve Backup Patch Manager 27.3.2.2 (Carcserver) On A Pc Or Mac Or Mac (Or Mac) CA ARCserve Backup Patch Manager for Windows User Guide r16 This Documentation, which includes embedded help systems and electronically distributed materials, (hereinafter referred to as the Documentation

More information

Oracle Enterprise Manager. Description. Versions Supported

Oracle Enterprise Manager. Description. Versions Supported Oracle Enterprise Manager System Monitoring Plug-in Installation Guide for Microsoft SQL Server Release 12 (4.1.3.2.0) E18740-01 November 2010 This document provides a brief description about the Oracle

More information

White Paper: BMC Service Management Process Model 7.6 BMC Best Practice Flows

White Paper: BMC Service Management Process Model 7.6 BMC Best Practice Flows White Paper: BMC Service Management Process Model 7.6 BMC Best Practice Flows October 2009 www.bmc.com Contacting BMC Software You can access the BMC Software website at http://www.bmc.com. From this website,

More information

User's Guide - Beta 1 Draft

User's Guide - Beta 1 Draft IBM Tivoli Composite Application Manager for Microsoft Applications: Microsoft Hyper-V Server Agent vnext User's Guide - Beta 1 Draft SC27-2319-05 IBM Tivoli Composite Application Manager for Microsoft

More information

How To Configure A Bomgar.Com To Authenticate To A Rdius Server For Multi Factor Authentication

How To Configure A Bomgar.Com To Authenticate To A Rdius Server For Multi Factor Authentication Security Provider Integration RADIUS Server 2015 Bomgar Corporation. All rights reserved worldwide. BOMGAR and the BOMGAR logo are trademarks of Bomgar Corporation; other trademarks shown are the property

More information

JAMF Software Server Installation Guide for Linux. Version 8.6

JAMF Software Server Installation Guide for Linux. Version 8.6 JAMF Software Server Installation Guide for Linux Version 8.6 JAMF Software, LLC 2012 JAMF Software, LLC. All rights reserved. JAMF Software has made all efforts to ensure that this guide is accurate.

More information

Online Backup Client User Manual

Online Backup Client User Manual Online Backup Client User Manual Software version 3.21 For Linux distributions January 2011 Version 2.0 Disclaimer This document is compiled with the greatest possible care. However, errors might have

More information

StreamServe Persuasion SP4

StreamServe Persuasion SP4 StreamServe Persuasion SP4 Installation Guide Rev B StreamServe Persuasion SP4 Installation Guide Rev B 2001-2009 STREAMSERVE, INC. ALL RIGHTS RESERVED United States patent #7,127,520 No part of this document

More information

Kaseya Server Instal ation User Guide June 6, 2008

Kaseya Server Instal ation User Guide June 6, 2008 Kaseya Server Installation User Guide June 6, 2008 About Kaseya Kaseya is a global provider of IT automation software for IT Solution Providers and Public and Private Sector IT organizations. Kaseya's

More information

CA Unified Infrastructure Management

CA Unified Infrastructure Management CA Unified Infrastructure Management Probe Guide for IIS Server Monitoring iis v1.7 series Copyright Notice This online help system (the "System") is for your informational purposes only and is subject

More information

Sametime Gateway Version 9. Deploying DMZ Secure Proxy Server

Sametime Gateway Version 9. Deploying DMZ Secure Proxy Server Sametime Gateway Version 9 Deploying DMZ Secure Proxy Server November 2013 Edition Notice Note: Before using this information and the product it supports, read the information in "Notices." This edition

More information

Deploying System Center 2012 R2 Configuration Manager

Deploying System Center 2012 R2 Configuration Manager Deploying System Center 2012 R2 Configuration Manager This document is for informational purposes only. MICROSOFT MAKES NO WARRANTIES, EXPRESS, IMPLIED, OR STATUTORY, AS TO THE INFORMATION IN THIS DOCUMENT.

More information

HP Service Manager. Software Version: 9.40 For the supported Windows and Linux operating systems. Application Setup help topics for printing

HP Service Manager. Software Version: 9.40 For the supported Windows and Linux operating systems. Application Setup help topics for printing HP Service Manager Software Version: 9.40 For the supported Windows and Linux operating systems Application Setup help topics for printing Document Release Date: December 2014 Software Release Date: December

More information

NETWRIX EVENT LOG MANAGER

NETWRIX EVENT LOG MANAGER NETWRIX EVENT LOG MANAGER ADMINISTRATOR S GUIDE Product Version: 4.0 July/2012. Legal Notice The information in this publication is furnished for information use only, and does not constitute a commitment

More information

BMC Impact Integration Developer s Kit Web Services Server Developer Guide

BMC Impact Integration Developer s Kit Web Services Server Developer Guide BMC Impact Integration Developer s Kit Web Services Server Developer Guide Supporting BMC Impact Integration Developer s Kit v. 7.1 BMC Impact Integration Web Services Server v. 7.1 January 2008 www.bmc.com

More information

Online Backup Client User Manual

Online Backup Client User Manual For Mac OS X Software version 4.1.7 Version 2.2 Disclaimer This document is compiled with the greatest possible care. However, errors might have been introduced caused by human mistakes or by other means.

More information

Enterprise Manager. Version 6.2. Installation Guide

Enterprise Manager. Version 6.2. Installation Guide Enterprise Manager Version 6.2 Installation Guide Enterprise Manager 6.2 Installation Guide Document Number 680-028-014 Revision Date Description A August 2012 Initial release to support version 6.2.1

More information

System Monitoring Plug-in for Microsoft SQL Server User s Guide Release 12.1.0.6.0 for Windows

System Monitoring Plug-in for Microsoft SQL Server User s Guide Release 12.1.0.6.0 for Windows [1]Oracle Enterprise Manager System Monitoring Plug-in for Microsoft SQL Server User s Guide Release 12.1.0.6.0 for Windows E35211-13 August 2015 Oracle Enterprise Manager System Monitoring Plug-in for

More information

VERITAS NetBackup 6.0 Encryption

VERITAS NetBackup 6.0 Encryption VERITAS NetBackup 6.0 Encryption System Administrator s Guide for UNIX, Windows, and Linux N15274C September 2005 Disclaimer The information contained in this publication is subject to change without notice.

More information

Idera SQL Diagnostic Manager Management Pack Guide for System Center Operations Manager. Install Guide. Idera Inc., Published: April 2013

Idera SQL Diagnostic Manager Management Pack Guide for System Center Operations Manager. Install Guide. Idera Inc., Published: April 2013 Idera SQL Diagnostic Manager Management Pack Guide for System Center Operations Manager Install Guide Idera Inc., Published: April 2013 Contents Introduction to the Idera SQL Diagnostic Manager Management

More information

IBM Aspera Add-in for Microsoft Outlook 1.3.2

IBM Aspera Add-in for Microsoft Outlook 1.3.2 IBM Aspera Add-in for Microsoft Outlook 1.3.2 Windows: 7, 8 Revision: 1.3.2.100253 Generated: 02/12/2015 10:58 Contents 2 Contents Introduction... 3 System Requirements... 5 Setting Up... 6 Account Credentials...6

More information

Symantec NetBackup for Lotus Notes Administrator's Guide

Symantec NetBackup for Lotus Notes Administrator's Guide Symantec NetBackup for Lotus Notes Administrator's Guide for UNIX, Windows, and Linux Release 7.5 Symantec NetBackup for Lotus Notes Administrator's Guide The software described in this book is furnished

More information

Installation and Configuration Guide for Windows and Linux

Installation and Configuration Guide for Windows and Linux Installation and Configuration Guide for Windows and Linux vcenter Operations Manager 5.7 This document supports the version of each product listed and supports all subsequent versions until the document

More information

CA Nimsoft Monitor. Probe Guide for Lotus Notes Server Monitoring. notes_server v1.5 series

CA Nimsoft Monitor. Probe Guide for Lotus Notes Server Monitoring. notes_server v1.5 series CA Nimsoft Monitor Probe Guide for Lotus Notes Server Monitoring notes_server v1.5 series Legal Notices This online help system (the "System") is for your informational purposes only and is subject to

More information

CA Performance Center

CA Performance Center CA Performance Center Single Sign-On User Guide 2.4 This Documentation, which includes embedded help systems and electronically distributed materials, (hereinafter referred to as the Documentation ) is

More information

How To Configure A Bmca Log File Adapter For Windows 2.5 (For Windows) For A Powerpoint 2.2 (For Microsoft) (For Ubuntu) (Powerpoint 2) (Windows) (Perl) (

How To Configure A Bmca Log File Adapter For Windows 2.5 (For Windows) For A Powerpoint 2.2 (For Microsoft) (For Ubuntu) (Powerpoint 2) (Windows) (Perl) ( BMC Impact Event Adapters User Guide Supporting BMC Event and Impact Management 2.0 BMC ProactiveNet Performance Manager 8.0 November 2009 www.bmc.com Contacting BMC Software You can access the BMC Software

More information

Data Access Guide. BusinessObjects 11. Windows and UNIX

Data Access Guide. BusinessObjects 11. Windows and UNIX Data Access Guide BusinessObjects 11 Windows and UNIX 1 Copyright Trademarks Use restrictions Patents Copyright 2004 Business Objects. All rights reserved. If you find any problems with this documentation,

More information

CA Nimsoft Monitor. Probe Guide for URL Endpoint Response Monitoring. url_response v4.1 series

CA Nimsoft Monitor. Probe Guide for URL Endpoint Response Monitoring. url_response v4.1 series CA Nimsoft Monitor Probe Guide for URL Endpoint Response Monitoring url_response v4.1 series Legal Notices This online help system (the "System") is for your informational purposes only and is subject

More information

CA XOsoft Replication for Windows

CA XOsoft Replication for Windows CA XOsoft Replication for Windows Microsoft SQL Server Operation Guide r12.5 This documentation and any related computer software help programs (hereinafter referred to as the Documentation ) is for the

More information

Installation Guide for Pulse on Windows Server 2008R2

Installation Guide for Pulse on Windows Server 2008R2 MadCap Software Installation Guide for Pulse on Windows Server 2008R2 Pulse Copyright 2014 MadCap Software. All rights reserved. Information in this document is subject to change without notice. The software

More information

HP Device Manager 4.7

HP Device Manager 4.7 Technical white paper HP Device Manager 4.7 LDAP Troubleshooting Guide Table of contents Introduction... 2 HPDM LDAP-related context and background... 2 LDAP in HPDM... 2 Full domain account name login...

More information

Sage 300 ERP 2014. Sage CRM 7.2 Integration Guide

Sage 300 ERP 2014. Sage CRM 7.2 Integration Guide Sage 300 ERP 2014 Sage CRM 7.2 Integration Guide This is a publication of Sage Software, Inc. Version 2014 Copyright 2013. Sage Software, Inc. All rights reserved. Sage, the Sage logos, and the Sage product

More information

Simba XMLA Provider for Oracle OLAP 2.0. Linux Administration Guide. Simba Technologies Inc. April 23, 2013

Simba XMLA Provider for Oracle OLAP 2.0. Linux Administration Guide. Simba Technologies Inc. April 23, 2013 Simba XMLA Provider for Oracle OLAP 2.0 April 23, 2013 Simba Technologies Inc. Copyright 2013 Simba Technologies Inc. All Rights Reserved. Information in this document is subject to change without notice.

More information

Siebel Installation Guide for UNIX. Siebel Innovation Pack 2013 Version 8.1/8.2, Rev. A April 2014

Siebel Installation Guide for UNIX. Siebel Innovation Pack 2013 Version 8.1/8.2, Rev. A April 2014 Siebel Installation Guide for UNIX Siebel Innovation Pack 2013 Version 8.1/8.2, Rev. A April 2014 Copyright 2005, 2014 Oracle and/or its affiliates. All rights reserved. This software and related documentation

More information

User's Guide - Beta 1 Draft

User's Guide - Beta 1 Draft IBM Tivoli Composite Application Manager for Microsoft Applications: Microsoft Cluster Server Agent vnext User's Guide - Beta 1 Draft SC27-2316-05 IBM Tivoli Composite Application Manager for Microsoft

More information

Bitrix Site Manager ASP.NET. Installation Guide

Bitrix Site Manager ASP.NET. Installation Guide Bitrix Site Manager ASP.NET Installation Guide Contents Introduction... 4 Chapter 1. Checking for IIS Installation... 5 Chapter 2. Using An Archive File to Install Bitrix Site Manager ASP.NET... 7 Preliminary

More information

AlarmPoint Adapter for BMC Remedy AR System by AlarmPoint Systems

AlarmPoint Adapter for BMC Remedy AR System by AlarmPoint Systems AlarmPoint Adapter for BMC Remedy AR System by AlarmPoint Systems User Guide Supporting AlarmPoint Adapter for BMC Remedy AR System by AlarmPoint Systems November 30, 2007 Contacting BMC Software You can

More information

Installation and Configuration Guide for Windows and Linux

Installation and Configuration Guide for Windows and Linux Installation and Configuration Guide for Windows and Linux vcenter Operations Manager 5.0.3 This document supports the version of each product listed and supports all subsequent versions until the document

More information

Installation Guide for Pulse on Windows Server 2012

Installation Guide for Pulse on Windows Server 2012 MadCap Software Installation Guide for Pulse on Windows Server 2012 Pulse Copyright 2014 MadCap Software. All rights reserved. Information in this document is subject to change without notice. The software

More information

CA Workload Automation Agent for Databases

CA Workload Automation Agent for Databases CA Workload Automation Agent for Databases Implementation Guide r11.3.4 This Documentation, which includes embedded help systems and electronically distributed materials, (hereinafter referred to as the

More information

Product Manual. MDM On Premise Installation Version 8.1. Last Updated: 06/07/15

Product Manual. MDM On Premise Installation Version 8.1. Last Updated: 06/07/15 Product Manual MDM On Premise Installation Version 8.1 Last Updated: 06/07/15 Parallels IP Holdings GmbH Vordergasse 59 8200 Schaffhausen Switzerland Tel: + 41 52 632 0411 Fax: + 41 52 672 2010 www.parallels.com

More information

Virtual Data Centre. User Guide

Virtual Data Centre. User Guide Virtual Data Centre User Guide 2 P age Table of Contents Getting Started with vcloud Director... 8 1. Understanding vcloud Director... 8 2. Log In to the Web Console... 9 3. Using vcloud Director... 10

More information

Out n About! for Outlook Electronic In/Out Status Board. Administrators Guide. Version 3.x

Out n About! for Outlook Electronic In/Out Status Board. Administrators Guide. Version 3.x Out n About! for Outlook Electronic In/Out Status Board Administrators Guide Version 3.x Contents Introduction... 1 Welcome... 1 Administration... 1 System Design... 1 Installation... 3 System Requirements...

More information

User Guide. CTERA Agent. August 2011 Version 3.0

User Guide. CTERA Agent. August 2011 Version 3.0 User Guide CTERA Agent August 2011 Version 3.0 Copyright 2009-2011 CTERA Networks Ltd. All rights reserved. No part of this document may be reproduced in any form or by any means without written permission

More information

CTERA Agent for Linux

CTERA Agent for Linux User Guide CTERA Agent for Linux September 2013 Version 4.0 Copyright 2009-2013 CTERA Networks Ltd. All rights reserved. No part of this document may be reproduced in any form or by any means without written

More information

CA ARCserve Replication and High Availability for Windows

CA ARCserve Replication and High Availability for Windows CA ARCserve Replication and High Availability for Windows Microsoft SQL Server Operation Guide r15 This documentation and any related computer software help programs (hereinafter referred to as the "Documentation")

More information

DS License Server. Installation and Configuration Guide. 3DEXPERIENCE R2014x

DS License Server. Installation and Configuration Guide. 3DEXPERIENCE R2014x DS License Server Installation and Configuration Guide 3DEXPERIENCE R2014x Contains JAVA SE RUNTIME ENVIRONMENT (JRE) VERSION 7 Contains IBM(R) 64-bit SDK for AIX(TM), Java(TM) Technology Edition, Version

More information