Beverage-Air Refrigerator Performance Testing
|
|
|
- Julianna Mills
- 10 years ago
- Views:
Transcription
1 Beverage-Air Refrigerator Performance Testing Application of ASHRAE FSTC Report # Final Report, January 2003 Prepared by: Fred Wong David Zabrowski David Cowen Fisher-Nickel, Inc. Contributor: Angelo Karas Scott Miner Fisher-Nickel, Inc by Fisher-Nickel, inc. All rights reserved. The information in this report is based on data generated at the.
2 Acknowledgments California consumers are not obligated to purchase any full service or other service not funded by this program. This program is funded by California utility ratepayers under the auspices of the California Public Utilities Commission. Los consumidores en California no estan obligados a comprar servicios completos o adicionales que no esten cubiertos bajo este programa. Este programa esta financiado por los usuarios de servicios públicos en California bajo la jurisdiccion de la Comision de Servicios Públicos de California. A National Advisory Group provides guidance to the Food Service Technology Center Project. Members include: Advantica Restaurant Group Applebee s International Group California Energy Commission (CEC) California Restaurant Association Carl Karcher Enterprises, Inc. DJ Horton & Associates Electric Power Research Institute (EPRI) Enbridge Gas Distribution EPA Energy Star Gas Technology Institute (GTI) Lawrence Berkeley National Laboratories McDonald s Corporation National Restaurant Association Pacific Gas and Electric Company Safeway, Inc. Southern California Edison Underwriters Laboratories (UL) University of California at Berkeley University of California at Riverside US Department of Energy, FEMP Policy on the Use of Food Service Technology Center Test Results and Other Related Information Fisher-Nickel, inc. and the (FSTC) do not endorse particular products or services from any specific manufacturer or service provider. The FSTC is strongly committed to testing food service equipment using the best available scientific techniques and instrumentation. The FSTC is neutral as to fuel and energy source. It does not, in any way, encourage or promote the use of any fuel or energy source nor does it endorse any of the equipment tested at the FSTC. FSTC test results are made available to the general public through technical research reports and publications and are protected under U.S. and international copyright laws. In the event that FSTC data are to be reported, quoted, or referred to in any way in publications, papers, brochures, advertising, or any other publicly available documents, the rules of copyright must be strictly followed, including written permission from Fisher-Nickel, inc. in advance and proper attribution to Fisher-Nickel, inc. and the Food Service Technology Center. In any such publication, sufficient text must be excerpted or quoted so as to give full and fair representation of findings as reported in the original documentation from FSTC. Legal Notice This report was prepared as a result of work sponsored by the California Public Utilities Commission (Commission). It does not necessarily represent the views of the Commission, its employees, or the State of California. The Commission, the State of California, its employees, contractors, and subcontractors make no warranty, express or implied, and assume no legal liability for the information in this report; nor does any party represent that the use of this information will not infringe upon privately owned rights. This report has not been approved or disapproved by the Commission nor has the Commission passed upon the accuracy or adequacy of the information in this report. Specific appreciation is extended to Beverage-Air, for supplying the with a 2-door reach-in refrigerator for controlled testing in the appliance laboratory.
3 Contents Page Background... 1 Objectives... 2 Appliance Description... 3 Setup and Instrumentation... 3 Test Procedure and Results... 5 Conclusions... 9 References Appendix A: Glossary Appendix B: Appliance Specifications iii
4 List of Figures and Tables Figures Page 1 Adjustable refrigeration shelving system Beverage-Air ER48-1A2 refrigerator Test simulator with thermocouple configuration Test simulator locations and configuration Shelf locations and test simulator configuration Hour individual test simulator temperatures Hour average shelf temperatures... 6 Tables Page 1 Appliance Specifications Energy Consumption Test Results Hour Temperature Performance Energy Consumption and Cost iv
5 Background Refrigeration is an integral, and potentially expensive, part of every food service establishment. Commercial refrigeration comprises 6% of a food service operation's energy use 1 ; in refrigeration-intensive operations, such as super markets, that percentage could be even higher. The American Society of Heating Refrigerating and Air-Conditioning Engineers (ASHRAE ) developed the BSR/ASHRAE Standard Method of Testing Closed Refrigerators, which determines the daily energy consumption of closed refrigerators. For many years the California Energy Commission (CEC) has been requiring manufacturers to provide energy performance numbers based on the ASHRAE test method (the predecessor of ASHRAE ) for any commercial refrigeration unit sold in the state of California for many years. The differences between and are changes in simulator mixture, placement of ambient temperature measurement device, and refrigerator loading scenario 2,3. The EPA has also established guidelines that determine performance criteria for the Energy Star label for refrigerators. Dedicated to the advancement of the food service industry, the Food Service Technology Center (FSTC) has focused on the development of standard test methods for commercial food service equipment since The primary component of the FSTC is a 10,000 square-foot appliance laboratory equipped with energy monitoring and data acquisition hardware, 60 linear feet of canopy exhaust hoods integrated with utility distribution systems, appliance setup and storage areas, and a state-of-the-art demonstration and training facility. Beverage-Air s double door reach-in refrigerator employs epoxy-coated rails for a multitude of shelf configurations, as well as a fan shut-off switch that operates when the doors open. This report presents the results of applying the ASHRAE test method to the Beverage-Air ER48-1AS double
6 door reach-in refrigerator. The glossary in Appendix A is provided so that the reader has a quick reference to the terms used in this report. Objectives The objective of this report is to examine the operation and performance of a Beverage-Air 48-inch double-door reach-in refrigerator, under the controlled conditions of the ASHRAE's standard Method of Testing Closed Refrigerators. The scope of this testing at the FSTC is as follows: 1. Verify that the appliance is operating at the manufacturer s rated energy input (current draw). 2. Document test simulator temperatures and appliance energy consumption during the 24-hour test. 3. Characterize the simulator temperatures and energy use during the 8-hour door openings and 16-hour idle. 4. Estimate the operating cost based on a standardized cost model. Appliance Description Beverage-Air s ER48-1AS, 48-inch double-door reach-in refrigerator includes epoxy coated wire rod slides (see Figure 1), which accommodates 18 x 26-inch (full size) sheet pans. The cavity is cooled by a top mounted system, which turns off when the doors are opened. The top and front are stainless steel, with aluminum comprising the case, interior and end panels (Figure 2). Figure 1. Epoxy coated rods for adjustable shelving
7 Nominal 2-inch thick R22 polyurethane insulation (foamed in place) prevents heat gain into the refrigerator cavity, while the two doors feature self-closing hinges and snap-in magnetic gaskets. Appliance specifications are listed in Table 1, and the manufacturer s literature is in Appendix B. Table 1. Appliance Specifications. Figure 2. Beverage-Air ER48-1AS Reach-In Refrigerator. Manufacturer Model Generic Appliance Type External Dimensions Shelf Configuration Current Rating Refrigerant Type Refrigerant Amount Design Pressure Construction Usable Volume Beverage-Air ER48-1AS Double-Door Reach-in Refrigerator 52" wide x 33.5" deep x 84.5" high (including casters) Epoxy Coated Wire Rod Slides volts R134A 14 oz 250 psig high; 250 psig low Stainless-steel doors and grill with steel gray acrylic finish for exterior sides. Exterior top bottom and back are galvanized steel, and an anodized aluminum finish interior 42.5 cubic feet Setup and Instrumentation Laboratory Set-Up The reach-in refrigerator was installed in an environmental room on a tiled floor, in accordance with the provision of the ASHRAE test method. During testing, the room was held at a dry bulb temperature of 75.2 ± 1.8 F and a wet bulb temperature of 64.4 ± 1.8 F. Air currents were 90 to the plane of the doors, with a velocity no greater than 49.2 fpm. Lighting within the test-room was no less than 74.4 foot-candles (800 Lux)
8 Test Simulator Packages Figure 3. Test simulator with thermocouple location and configuration. The tests were conducted using plastic containers with lids and were 1 U.S. liquid pint by volume. Each container held an artificial sponge material and was filled with a heat transfer solution. The test packages were divided into two groups: test simulators and filler packages. The filler packages contained foam and water. The test simulators packages contained foam and a 50% by volume, solution of propylene glycol and distilled water. Each test simulator package was instrumented with a thermocouple in the geometric center to measure the temperature of the solution during the test period (Figure 3). Instrumentation A total of twenty-four test simulators were used to measure the temperature of simulated food product during the 24-hour test. Due to the adjustable shelving design in the Beverage-Air, sheet pans were placed at intervals specified by the ASHRAE standard of 20 inches center to center between test simulators. Each shelf was loaded with four test simulator packages - one at each corner. Figure 4 illustrates the position of the test simulator packages. Figure 4. Test simulator placement
9 The ASHRAE standard specifies that at least 20% of the remaining available refrigerator volume be filled with filler packages, where test simulators are not required. Filler packages consisted of the same foam-filled plastic containers with water replacing the mixture of propylene glycol and distilled water. Figure 5 represents the filler packages, test simulators, and shelf positions within the test refrigerator. Electrical energy consumption was measured with a Watt-hour transducer that generated a pulse for every watt-hours. The transducer and thermocouples were connected to an automated data acquisition unit that recorded data every 5 seconds. Energy consumption and input rates were calculated and temperature profiles were generated from this information. Test Procedure and Results 24-Hour Test The refrigerator was stabilized to achieve test simulator temperatures of 38 ± 2 F, as mandated by the California Energy Commission (CEC) for a period where repetitive conditions exist. Researchers conducted a 24-hour test, which incorporates two operating scenarios: 8 hours with door openings and 16 hours with the doors closed (idle state). During the door-opening portion of the test, each door was opened for six seconds to an angle greater than 75 degrees, six times an hour (once every ten minutes). This door-opening portion was designed to emulate normal operation during the day. The unit consumed an average of kw during the 24-hour test, while maintaining an average test simulator temperature of 40 F. Figures 6 and 7 show the test simulator temperatures during the 24-hour test. Figure 5. Shelf locations and configuration
10 46 Average Temperature Highest Temperature Lowest Temperature Figure Hour individual test simulator temperatures. Test Simulator Temperature ( F) Shelf #1 Shelf #2 Shelf #3 32 Top Bottom Test Simulator Position 46 Shelf #1 Shelf #2 Shelf # hour Door Openings Temperature ( F) Figure Hour average shelf temperatures Test Time (hr)
11 Test Results Compressor percentage run time, or duty cycle, was calculated during the 24- hour test. Duty cycle was further calculated for the 8-hour door opening portion and 16-hour idle portion. The compressor exhibited more frequent, short on-cycles during the 8-hour door-opening test. The average energy consumption rates during the 8-hour and 16-hour portions were kw and kw, respectively. Ambient air entering the refrigerator cavity during the door openings was the primary reason for the 28% increase in energy consumption rate. During the idle state, any loss of cavity temperature was due to heat transfer through the insulation and door seals. Table 2 summarizes the test results for the energy consumption of the refrigerator. The Beverage-Air was able to maintain an average test simulator temperature of 40 F over the 24- hour test period. Though ASHRAE does not currently require a specified temperature range, the CEC requires a range of 38 ± 2 F for average simulator temperature. Table 3 summarizes the temperature data for the Beverage-Air refrigerator test. With an average energy consumption rate of approximately kw during the 24-hour test, the Beverage-Air refrigerator used 11% less energy than a previously tested refrigerator at the Food Service Technology Center. 4 Table 2. Energy Consumption Test Results. 8-Hr Door Openings 16-Hr Idle 24-Hr Test Compressor Duty Cycle (%) Fan Energy Consumption (kwh) Compressor Energy Consumption (kwh) Total Energy Consumption (kwh) Energy Consumption Rate (kw)
12 Table Hour Temperature Performance. Ambient Dry-Bulb Temperature ( F) 74.2 Ambient Wet-Bulb Temperature ( F) 63.5 Average Temperature (AT) for All Test Simulators ( F) 40 Coldest Test Simulator Average (CTSA) Temperature ( F) 38.6 Coldest Test Simulator (CTS) Temperature ( F) 36.9 Warmest Test Simulator Average (WTSA) Temperature ( F) 41.0 Warmest Test Simulator (WTS) Temperature ( F) 42.1 Energy Model Researchers developed an energy usage/cost model to estimate annual user costs. The model is based on operational energy use from both the door openings and closed door conditions. The door opening condition was used to estimate daily energy use of the unit, while the closed door condition was used to estimate idle state during the night. The model assumed 24 operating hours per day, 365 days per year. The energy cost was based on $0.10/kWh, a typical average energy rate for the United States. Energy consumption and operating cost are summarized in Table 4. Table 4. Energy Consumption and Cost. Energy Consumption (kwh/yr) Annual Operating Cost ($/yr) Door Openings Door Closed 1, Total 1,
13 Conclusions Beverage-Air's double-door reach-in refrigerator performed well during the comprehensive laboratory testing. The unit was capable of maintaining the CEC required test simulator temperatures during both door-opening and closed door portions of 38 ± 2 F. Energy consumption rate was low, at kw for the 24-hour test relative to units previously tested at the FSTC. The reported energy consumption under is higher than it would be under due to the loading scenario that was used for this test (unit was loaded to 20% capacity instead of 100% as required for ). Furthermore, the Beverage-Air's low energy use qualifies it as an Energy Star refrigerator
14 References 1. Claar, C.N., Mazzucchi, R.P., Heidell, J.A., The Project on Restaurant Energy Performance (PREP) - End-Use Monitoring and Analysis. Prepared for the Office of Building Energy Research and Development, DOE, May. 2. American Society of Heating, Refrigerating and Air-Conditioning Engineers. ASHRAE Method of Testing Closed Refrigerators. Atlanta. American Society of Heating, Refrigerating and Air- Conditioning Engineers. Atlanta, GA. 3. American Society of Heating, Refrigerating and Air-Conditioning Engineers. ASHRAE Method of Testing Closed Refrigerators. Atlanta. American Society of Heating, Refrigerating and Air- Conditioning Engineers. Atlanta, GA Traulsen Two-Door Reach-In Refrigerator Performance Test. Report prepared for Customer Energy Management. San Francisco. Pacific Gas and Electric Company. 5. Environmental Protection Agency Energy Star Qualified Commercial Solid Door Refrigerators and Freezers
15 A Glossary Coldest Test Simulator Average ( F) CTPA The test simulator with the coldest average temperature over the test period. Coldest Test Simulator ( F) CTP The coldest temperature reached of the test simulator with the coldest average temperature. Coldest Test Simulator Average Temperature, ( F) CTSA The test simulator with the coldest average temperature over the test period. Coldest Test Simulator ( F) CTS The coldest temperature reached of the test simulator with the coldest temperature. Compressor Duty Cycle (%) The calculated percentage compressor "on" time or run time. Dry Bulb Temperature ( F) DB Temperature The ambient air temperature. Duty Cycle (%) Load Factor The average energy consumption rate (based on a specified operating period for the appliance) expressed as a percentage of the measured energy input rate. Duty Cycle = Average Energy Consumption Rate MeasuredEnergy Input Rate x 100 Energy Input Rate (kw or kbtu/h) Energy Consumption Rate Energy Rate The peak rate at which an appliance will consume energy, typically reflected during preheat. Filler Material Material consisting of water, or of a mixture of 50% 2% distilled water and 50% 2% propylene glycol, or wood blocks with an overall density not less than 480 kg/m 3 (30 lb/ft 3 ); used for filling the refrigerator spaces not occupied by test simulators. Filler Package Dummy Package Packages used as product mass, consisting of containers with filler material that closely follow food product characteristics, used to fill the spaces between test simulators for product mass A-1
16 Glossary Idle Energy Rate (kw or Btu/h) Idle Energy Input Rate Idle Rate The rate of appliance energy consumption while it is idling or holding at a stabilized operating condition or temperature. Intergrated Average Temperature, IAT ( F) Average Temperature, AT ( F) The average temperature of all of the test simulators over the test period. Measured Input Rate (kw or Btu/h) Measured Energy Input Rate Measured Peak Energy Input Rate The maximum or peak rate at which an appliance consumes energy, typically reflected during the initial appliance draw-down or cooldown period (i.e., the period of operation when the compressor(s) are on ). Rated Energy Input Rate (kw, W or Btu/h, Btu/h) Input Rating (ANSI definition) Nameplate Energy Input Rate Rated Input The maximum or peak rate at which an appliance consumes energy as rated by the manufacturer and specified on the nameplate. Test Simulator Package Test Simulator A 1 U.S. pint (473 ml) container holding a sponge and a 50%-50% solution of water and propylene glycol with a thermocouple to measure the center temperature of the container. Warmest Test Simulator( F) WTS The highest temperature recorded of the test simulator with the warmest average temperature over the test period. Warmest Test Simulator Average( F) WTPA The test package with the warmest average temperature over the test period. Warmest Test Simulator Average( F) WTSA The test simulator with the warmest average temperature over the test period. Wet Bulb Temperature ( F) WB Temperature An air temperature where the temperature is a function of the saturation of the air. Relative Humidity (%) RH A measurement of the degree of saturation of air, with 100% indicating completely saturated air and 0% indicating completely dry air. Test Method A definitive procedure for the identification, measurement, and evaluation of one or more qualities, characteristics, or properties of a material, product, system, or service that produces a test result A-2
17 B Manufacturer Specifications Appendix B includes the product literature for the Beverage-Air ER48-1AS refrigerator B-1
18 Item No Quantity BEVERAGE-AIR COMMERCIAL REFRIGERATION EQUIPMENT GENERAL SPECIFICATIONS REACH-IN REFRIGERATORS E-Series MODELS: ER24 ER48 ER74 CONSTRUCTION: Heavy duty construction includes stainless front (doors and grilles) with #3 finish. Exterior sides are steel with gray, acrylic finish. Exterior top, back, and bottom are galvanized steel. Exterior mounted thermometer is drum type. Interior cabinet liner is anodized aluminum finish. Interior pilasters are regular type. Interior shelves are steel wire-coated. Cabinets are insulated with R22 foamed-in-place polyurethane insulation, 2" minimum thickness. All doors are full size unless specified half size and include keyed door locks as standard with solid doors. Doors attach to cabinet on cam lift hinges. Hinges permit doors to stay open at 120 degrees and gravity self-close. A plug-in type, vinyl magnetic gasket is attached to each door. Shelves are adjustable on 1/2" centers. Traffic tough work flow handle is standard. Door openings include low wattage, anti-condensate heaters. A switch located at the top of each full door opening activates light and shuts off evaporator fan motor(s) when door is opened. Six inch, adjustable, corrosion resistant legs are standard. A 9' cord is provided with models. ER24 REFRIGERATION: Unit s system is located at top of cabinet. A capillary tube is used to meter R134a refrigerant between condenser and high humidity, coated evaporator coil. Temperature control is located behind front grill. Hot gas (nonelectrical) condensate evaporator is located at top of cabinet. AIR DISTRIBUTION: Beverage-Air s unique down-duct air distribution provides the ideal environment for food preservation. Refrigerated air is discharged from an insulated evaporator coil compartment located above the interior top of cabinet into a distribution plenum. From the plenum, air is discharged down both sidewalls one half way back. In two section models, 3-way air discharge is accomplished with an additional down duct located on the center of the back wall from the discharge plenum to the floor. In three section models, 4-way air discharge is accomplished with two additional down ducts located on the back wall. Air is returned upward across the full width of the interior into a louvered plenum assuring even temperatures throughout the cabinet. Made in USA ER48 Optional Half (Solid or Glass) Doors Available In All Models ER74 C-UL Standard on all models except ER74, must be specified a Specialty Equipment company PO BOX 5932, Spartanburg, SC Fax #
19 File # Spec. ER24, ER48, ER74 Reach-In Refrigerators SPECIFICATIONS ER24 SOLID DOOR GLASS DOOR Exterior Width 26" 26" Exterior Depth, Overhandle 33 1/2" 33 1/2" Exterior Height, With Legs 84 1/2" 84 1/2" Cubic Feet Cabinet Voltage (50 Cycle Available) Horsepower 1/4 1/4 Amps Recommended BTU/HR* Crated Weight Shelves 3 3 Shelf Dimension 20 3/4" x 26" 20 3/4" x 26" SPECIFICATIONS ER48 SOLID DOOR GLASS DOOR Exterior Width 52" 52" Exterior Depth, Overhandle 33 1/2" 33 1/2" Exterior Height, With Legs 84 1/2" 84 1/2" Cubic Feet Cabinet Voltage (50 Cycle Available) Horsepower 1/3 1/3 Amps Recommended BTU/HR* Crated Weight Shelves 6 6 Shelf Dimension 20 3/4" x 26" 20 3/4" x 26" SPECIFICATIONS ER74 SOLID DOOR GLASS DOOR Exterior Width 78" 78" Exterior Depth, Overhandle 33 1/2" 33 1/2" Exterior Height, With Legs 84 1/2" 84 1/2" Cubic Feet Cabinet Voltage (50 Cycle Available) Horsepower 1/2 3/4 Amps Recommended BTU/HR* Crated Weight Shelves 9 9 Shelf Dimension 20 3/4" x 26" 20 3/4" x 26" NOTES: *Net refrigeration capacity of cabinet at 20 F evaporator temperature & 120 F condenser temperature. Heat load generated by cabinet is 2565 BTU/HR for ER24, 3375 for ER48, and 6143 for ER74. ER BW PAN AND TRAY SLIDE COMBINATIONS NO. 1 STAINLESS STEEL ANGLE SLIDE Part No. 61C08-007A Each pair rim supports 2 ea. 12"x 20" hotel pans - 3" minimum spacing Requires use of heavy duty pilaster kit No. 61C08-010A (2 required per section) Max. Cap. 16Pr/Sec NO. 2 STAINLESS STEEL ANGLE SLIDE Part No. 61C08-008A Each pair rim supports 1 ea. 18" x 26" bun pan or 2 ea. 14"x 18" bun pans - 2" minimum spacing Requires use of wide pilaster, kit No. 61C08-011A (2 required per section) Max. Cap. 26Pr/Sec NO. 3 STAINLESS STEEL ANGLE SLIDE Part No. 61C08-009A Each pair bottom supports 2 ea. 12" x 20" hotel pans or 1 ea. 18" x 26" bun pan or 2 ea. 14" x 18" bun pans Requires use of heavy duty pilaster, kit No. 61C08-010A (2 required per section) Max. Cap. 16Pr/Sec NO. 4 EPOXY COATED WIRE ROD SLIDE Part No. 61C31-053A Rim supports a maximum of 19 ea. 18" x 26" bun pans per half section with 1 1/2" fixed spacing Pilasters not required - Adjustable to pan width Max. Cap. 38Pr/Sec OPTIONAL EQUIPMENT Stainless Steel Breakers Prison Package Casters Remote Hook-Up Digital Thermometer Gastronorm Pan Slides (Check factory) Rehinging of Doors Stainless Steel Shelves Half Solid Doors Half Glass Doors Full Glass Doors Locks - Glass Door a Specialty Equipment company PO BOX 5932, Spartanburg, SC Fax #
Traulsen Two-Door Reach-In Refrigerator Performance Test
Traulsen Two-Door Reach-In Refrigerator Performance Test In accordance with ASHRAE 117-1992R Method of Testing Closed Refrigerators FSTC Report 5011.99.73 Food Service Technology Center Final Report, December
HOSHIZAKI AMERICA, INC.
Item #40096 10/27/2014 1 HOSHIZAKI AMERICA, INC. Hoshizaki America has built a legacy of quality design, reliability and customer commitment. In our Commercial Series refrigeration line, you ll see solutions
MAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
SECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
ULT Freezer Performance Testing Emerson Design Services Network Project # 111686
ULT Freezer Performance Testing Emerson Design Services Network Project # 111686 Design Services Network Test Performed by: Dan Rice & Don Wenrich Design Services Network Report Prepared by: Robert V.
VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water
2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation
Southbend Simple Steam, Model EZ-3 Electric Steamer Performance Test
Southbend Simple Steam, Model EZ-3 Electric Steamer Performance Test Application of ASTM Standard Test Method F 1484-99 FSTC Report 5011.99.83 Food Service Technology Center Manager: Don Fisher Final Report,
ARMSTRONG AIR HEAT PUMPS www.armstrongair.com
INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7
HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons
Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM Comfort Comfort is determined
Element D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Coldrooms designed for your application
UK Price Book 2013 Coldrooms Coldrooms designed for your application Foster Coldstores has a wealth of experience in the manufacture and supply of coldrooms. We can satisfy all business needs ranging from
SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
Performance Rating of Room Fan- Coils
ANSI/AHRI Standard 440 with Addendum 1 (Formerly ARI Standard 440) 2008 Standard for Performance Rating of Room Fan- Coils ANSI/AHRI STANDARD 440-2008 WITH ADDENDUM 1, PERFORMANCE RATING OF ROOM FAN-COILS
Mechanical Rooftop Custom Capabilities
Mechanical Rooftop Custom Capabilities Mechanical Construction Capabilities Price manufactures a wide range of custom gas heat and DX cooled units to meet your new construction and retrofit needs. In addition
Middleby Marshall, Model PS570 Conveyor Oven Performance Test
Middleby Marshall, Model PS570 Conveyor Oven Performance Test Application of ASTM Standard Test Method F 1817-97 CKVL Report 0011107 April 2003 Prepared by: Rich Swierczyna Paul Sobiski Architectural Energy
PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS
NOR-LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-4291 FAX www.norlake.com Split-Pak Pre-Assembled
Refrigerators - Freezers. Ekofrigolab & Ekobasic Series
Refrigerators - Freezers Ekofrigolab & Ekobasic Series Angelantoni Life Science S.r.l. manufactures a wide range of refrigerated cabinets and combined refrigerator/freezer cabinets. We offer high reliability
Commercial Portable Air Conditioners
Commercial Portable Air Conditioners Air Rover commercial portable air conditioners provide the environmental stability and comfort required by today s sensitive equipment, allowing your business to avoid
COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.
COIL INPUT SCREENS Example of a Water Coil Input Screen: (*please see the appendix for an example of an Evaporator, Steam or Condenser Coil input screen) PHYSICAL DATA ITEM NUMBER: Always use a 1 through?
26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.
T H R U - T H E - W A L L A I R C O N D I T I O N E R S 26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. W A L L M A S T E R T H R U - T H E - W A L L A I R C O N D I T I O N E R
TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series
TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series The range of E-Pro cold units includes various types of refrigerated units and worktops. Thanks to the flexible
Commercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
Enclosure and Airflow Management Solution
Enclosure and Airflow Management Solution CFD Analysis Report Des Plaines, Illinois December 22, 2013 Matt Koukl- DECP Mission Critical Systems Affiliated Engineers, Inc. Contents Executive Summary...
Ice Machine Field Study: Energy and Water Saving with Ice Machine Upgrade and Load Shifting
Ice Machine Field Study: Energy and Water Saving with Ice Machine Upgrade and Load Shifting FSTC Report 501310087 Food Service Technology Center September 2011 Prepared by: Angelo Karas David Cowen Don
Bring the fresh in. Dedicated Outside Air Systems
Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
APC APPLICATION NOTE #112
#112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.
Cold Room & Refrigeration System (Casserole Assembly) No of units: 1
Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency
SINGLE PACKAGE VERTICAL AIR CONDITIONERS
SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,
Cabinets 101: Configuring A Network Or Server Cabinet
Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What
SECTION 15732 AIR CONDITIONING UNIT
SECTION 15732 AIR CONDITIONING UNIT PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Packaged, split system air conditioning unit No. 1. 1.02 REFERENCES A. Air-Conditioning, Heating, and Refrigeration
A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.
SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel
Troubleshooting Your Refrigerator
Troubleshooting Your Refrigerator With conscientious care, a refrigerator will perform for years with little or no repairs. Refrigerators are categorized according to the way frost is removed from them.
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
Single Package Vertical Air Conditioners. Vert-I-Pak
Single Package Vertical Air Conditioners Vert-I-Pak Installs easily in a closet for quiet operation and provides a more homelike appearance for your guests. THE EXPERTS IN ROOM AIR CONDITIONING A Better
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
Light Duty Commercial Electric Water Heater
Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and
MovinCool Office Pro Series. The Portable Spot Cooling Solution
MovinCool Office Pro Series The Portable Spot Cooling Solution The Office Pro 2002 American Standard Inc. All rights reserved Losing Is Not An Option With The Office Pro Series. The loss of data and equipment
Answers to Your Questions from the Webinar
2008 Desert Aire and USA Swimming. Used by permission. Desert Aire & USA Swimming - Aquatics Webinar - Answers to Your Questions Answers to Your Questions from the Webinar Thank you for your interest in
Morgue refrigeration unit
Morgue refrigeration unit The Morgue refrigeration units are made of sturdy, self-supporting walls, floor and ceiling elements. They are delivered in separate components and are to be assembled on site
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions
WAECO COOLMATIC 2.8 CUBIC FEET 12/24 VOLTS DC & 110 / 220 VOLTS AC BUILT-IN REFRIGERATOR-FREEZER WITH FLUSH MOUNT FRAME
Well after screwing around with the old Norcold refrigerator for the past 2 years I finally decided to search for a replacement. I looked at the Wal-Mart offerings but just did not like the look and feel
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C
COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing
Vertical Display and Storage B1350-2. SKOPE Gen2: Three Door Chiller
Vertical Display and Storage User Manual MAN1227 Rev. 3.0 March 2008 edition CONTACT ADDRESSES Designed and Manufactured by New Zealand SKOPE INDUSTRIES LIMITED PO Box 1091, Christchurch New Zealand Freephone:
Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.
Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,
A. Section includes air conditioning units, controls and control panels.
SECTION 23 81 23 - COMPUTER-ROOM AIR-CONDITIONERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes air conditioning units, controls and control panels. 1.2 REFERENCES A. Air-Conditioning, Heating, and
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
Low Profile Unit Cooler
Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost
BEVERAGE-AIR PARTS MANUAL FOR DD/BB/BM/GF/MS ALL PURPOSE COLD DIRECT DRAW BACK BAR BAR MOBILE GLASS FROSTER MIXED STORAGE 115V/60HZ 220V/50HZ
BEVERAGE-AIR PARTS MANUAL FOR DD/BB/BM/GF/MS ALL PURPOSE COLD DIRECT DRAW BACK BAR BAR MOBILE GLASS FROSTER MIXED STORAGE 115V/60HZ 220V/50HZ DD/BB/MS SECTION TABLE OF CONTENTS BM23 SECTION PART PAGE NUMBER
III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014
III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III.1. Large Roof Mount PN: 89-3037 Roof Mount Unit Eco 136 Parallel roof mount Air-conditioning and ventilation systems The Eco 136
All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
Energy Efficiency. Energy Efficient Home Cooling:
Energy Efficiency Energy Efficient Home Cooling: Choosing an air conditioning system is an important decision. A poor choice may be costly to purchase and operate and yet fail to provide the desired cooling
Heating oven with mechanical convection
FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous
IV. Rear Mount System
Mobile Climate Control 45 MCC Reference Manual 2014 PN: 89-3069 Rearmount Air Conditioning System Eco RM Capacity, Reliability, and Serviceability MCC Eco RM unit, selected as preferred equipment by leading
ARTS AND CRAFTS 10.1.0. 5410 (open) 5412 (doors) H : 84" Tote Tray Storage. Damp Storage. Tote Tray Storage. Notebook Board Storage, Doors
Drawing Board Storage, Open Drawing Board Storage, Doors Drawing Board Storage Notebook Storage, Open 1670 D : 23.25" holds 32 drawing boards 1 shelf, adjustable on 1¼" increments maximum board height
SECTION 23 81 43 HEAT PUMPS
SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:
Air Conditioning Sign-Off Sheet
Air Conditioning Sign-Off Sheet Printed Technician Name Address Social Security Number Telephone Number City State Zip Code Install Or Verify The Accuracy Of An Air Conditioner s Installation The candidate
Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC
TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while
Incubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air
technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
PREVENTATIVE MAINTENANCE
PREVENTATIVE MAINTENANCE PREVENTIVE MAINTENANCE Sandwich Unit: Proper Operation Turn on at least 45 minutes before loading Load only pre-chilled food 34-37 F Move quickly from walk-in to sandwich unit
This permit does not include replacement or upgrading of the existing electrical panel or service (a separate electrical permit must be obtained).
CITY OF MILPITAS Building & Safety Department 455 E. Calaveras Blvd. Milpitas, CA 95035 408-586-3240 www.ci.milpitas.ca.gov RESIDENTIAL AIR CONDITIONING, REPLACEMENT 1. PERMIT INFORMATION: The replacement
INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-213 REV. 4 Supersedes Form No. C11-213 Rev. 3 INDOOR COILS RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM
Total Heat Versus Sensible Heat Evaporator Selection Methods & Application
Total Heat Versus Sensible Heat Evaporator Selection Methods & Application Scope The purpose of this paper is to provide specifying engineers, purchasers and users of evaporators in industrial refrigeration
MUELLER FALLING FILM CHILLERS
MUELLER FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS ARE DESIGNED TO COOL ANY FLUID TO WITHIN 2 F OF ITS FREEZE POINT. The primary application for Mueller s falling film chiller is to cool food-grade
M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60
ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac II air conditioner is a vertical, wall mounted, cost effective air conditioner
MAYTAG MFD2560HEB NACIONAL E IMPORTACIÓN CABINET BACK
CABINET BACK 1 CABINET BACK 1 12575101ED BACK, MACH COMP 2 67004098 COVER, WATER VALVE 3 M0238616 SCREW, SM 4 M0251015 SCREW 5 B5759649 GASKET, MC BACK 6 67004092 BLOCK, FILTER 7 M0211018 SCREW, SM 8 67003729
Air Conditioners Technical Data
Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-JV Outdoor Unit RX-JV TABLE OF CONTENTS RX-JV Features............................................................. 2 2 Specifications.......................................................
Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System
Auxiliary HVAC RAM ProMaster Standard Tie-in Extreme Climate System Auxiliary HVAC High performance aftermarket heating and cooling systems engineered for vehicle specific platforms that minimize install
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
3Aftermarket Systems. Air Conditioners and Kombos.. 411. Heater/Pressurizer...440. System Matrix...441. Aftermarket System Requirements...
3Aftermarket Systems Air Conditioning & Heating Replacement Parts Aftermarket Systems Air Conditioners and Kombos.. 411 KA-300 Air Conditioner... 411 KK-315 Heater/Air Conditioner Kombo...412 KA-400 Air
marine/bespoke split applications
split applications marine/bespoke evaporators, condensers and split air conditioning systems suitable for a multitude of applications such as coastal, extreme high and low ambients, harsh dusty environments
EFFECTS OF INDOOR RELATIVE HUMIDITY ON REFRIGERATED DISPLAY CASE PERFORMANCE
P (5, EFFECTS OF INDOOR RELATIVE HUMIDITY ON REFRIGERATED DISPLAY CASE PERFORMANCE Ronald H. Howell, Professor Luis Rosario, Graduate Student Antonio Bula, Graduate Student Department of Mechanical Engineering
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL Service Information If service or parts are required, contact the nearest Norcold Service Center. To find an authorized Norcold Service Center
air conditioners how to choose a cooling system
air conditioners how to choose a cooling system taking responsibility As an individual, your efficient use of energy brings benefits such as lower bills, improved comfort levels in your home and a reduced
Conserve O Gram. Cold Storage for Photograph Collections Using Individual Freezer Units. Introduction. Types of Freezers. August 2009 Number 14/11
Conserve O Gram August 2009 Number 14/11 Cold Storage for Photograph Collections Using Individual Freezer Units Introduction Most photograph collections can benefit from cold storage. When collections
Case Studies in Restaurant Water Heating
Case Studies in Restaurant Water Heating Donald Fisher, Fisher-Nickel, Inc. William Pietrucha, Pacific Gas and Electric Company ABSTRACT This paper presents an overview of hot water use and the associated
REFRIGERATION. Standard Features & Accessories. Model Options. Built-In 30 W. Full-Height Wine Cellar. All models include. VCWB300 Professional
Standard Features & Accessories All models include Capacity accommodates up to 150 full-size bottles o 84 H./24 D. Exclusive TriTemp storage system o Three independent temperature zones o Settings are
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
Integral Kit Instructions
Integral Kit Instructions For Fisher & Paykel Cabinet widths of 525, 635, 680, 790 mm wide For curved door Models Series B, C, D & G Manual 814980 Updated August 2008 IMPORTANT If your refrigerator has
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
Safety. Fire Resistant. Gas Cylinder
All Cabinets Ship Flyer CAB09...Many in 48 hrs. Heavy Duty All Welded CABINETS 31 Models Safety Fire Resistant Spill Containment Gas Cylinder Made in USA Distributed By: Our Quality Serves You Longer JAMCO
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
French Door Refrigerator E23BC78IPS professional series
French Door Refrigerator E23BC78IPS professional series 23 CU. FT. COUNTER-DEPTH FRENCH DOOR REFRIGERATOR Custom Temp Drawer Enjoy the ultimate in versatility with 9 preset selections including White/Sparkling
Cased/Uncased Coils For Gas And Oil Furnaces
Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Rheem Indoor Coils are designed for use
FOXAIR 60/50 ALL MODELS
FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,
SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION
SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION The purpose of this guide specification is to assist the specifier in correctly specifying Mechanical System Testing
Access Server Rack Cabinet Compatibility Guide
Access Server Rack Cabinet Compatibility Guide A Guide to the Selection and Evaluation of Access Server Rack Cabinets for Compatibility and Use with Third Party Server Chassis Kalkenstraat 91-93 B-8800
LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_071015. Products that provide lasting solutions.
LH and GH/GL Series UNIT COOLERS Technical Bulletin: LHGH_001_07101 Products that provide lasting solutions. LH Series Unit Coolers Dual Discharge Low Hite Series At 9 1/ maximum height, the LH Series
CE6500 Energy Recovery Ventilator
ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge
Pacific Gas and Electric Company Energy-Efficiency Rebates for Your Business. Refrigeration Rebate Catalog Saving energy for a brighter future
Pacific Gas and Electric Company Energy-Efficiency s for Your Business Refrigeration Catalog Saving energy for a brighter future Table of Contents Pacific Gas and Electric Company (PG&E) offers financing