User Manual. Installation Industrial ETHERNET Rail Switch RS20/RS30 Family. RS20/RS30 Release /06. Technical support
|
|
|
- Amber McGee
- 10 years ago
- Views:
Transcription
1 User Manual Installation Industrial ETHERNET Rail Switch Family RS0 RS0 RS0 +V() 0V 0V +V() +V() 0V 0V +V() +V () 0V 0V +V () I-ADDRESS 9 0 V. I-ADDRESS V. I-ADDRESS V RS0 with ports RS0 with ports RS0 with ports RS0 RS0 +V() 0V 0V +V() +V() 0V 0V +V() I-ADDRESS 9 0 V. I-ADDRESS V RS0 with 6 ports RS0 with 0 ports Release.0 0/06 Technical support [email protected]
2 The naming of copyrighted trademarks in this manual, even when not specially indicated, should not be taken to mean that these names may be considered as free in the sense of the trademark and tradename protection law and hence that they may be freely used by anyone. 006 Hirschmann Automation and Control GmbH Manuals and software are protected by copyright. All rights reserved. The copying, reproduction, translation, conversion into any electronic medium or machine scannable form is not permitted, either in whole or in part. An exception is the preparation of a backup copy of the software for your own use. The performance features described here are binding only if they have been expressly guaranteed in the contract. This publication has been created by Hirschmann Automation and Control GmbH according to the best of our knowledge. Hirschmann reserves the right to change the contents of this manual without prior notice. Hirschmann can give no guarantee in respect of the correctness or accuracy of the details in this publication. Hirschmann can accept no responsibility for damages, resulting from the use of the network components or the associated operating software. In addition, we refer to the conditions of use specified in the license contract. rinted in Germany (0..06) Hirschmann Automation and Control GmbH Stuttgarter Straße Neckartenzlingen Tel
3 Content Safety instructions About this manual Legend Device description 9. Description of the device variants 0.. combination options.. RS0-... number of ports and media.. RS0-... number of ports and media Assembly and startup procedure 6. Device installation 6.. Unpacking and checking 6.. Filling out the labeling field 6.. Adjusting the DI switch settings 7.. Connecting the terminal block for supply voltage and signal contact 7..5 Fitting the device on the ISO/DIN rail, grounding..6 Fitting the terminal block, startup procedure 9..7 Connecting the data lines 9. Displays. Carrying out basic settings. Disassembling the device Technical data 5 General data 5 EMV and stability 6 Network size 7 ower consumption/power output Scope of delivery Order numbers/product name Accessories 9 Based specifications and standards 9 Certifications 0 Further support Release.0 0/06
4 Safety instructions This manual contains instructions which must be observed to ensure your own personal safety and to avoid damage to devices and machinery. U Certified usage lease observe the following: The device may only be employed for the purposes described in the catalog and technical description, and only in conjunction with external devices and components recommended or approved by Hirschmann. The product can only be operated correctly and safely if it is transported, stored, installed and assembled properly and correctly. Furthermore, it must be operated and serviced carefully. U Supply voltage The devices are designed for operation with a safety extra-low voltage.thus, they may only be connected to the supply voltage connections and to the signal contact with ELV circuits or alternatively SELV circuits with the voltage restrictions in accordance with IEC/EN The supply voltage is electrically isolated from the housing. V Use only undamaged parts! V Relevant for North America: The subject unit is to be suppplied by a Class power source complying with the requirements of the National Electrical Code, table (b). If power is redundant supplied (two individual power sources) the power sources together should comply with the requirements of the National Electrical Code, table (b). V Relevant for North America: Use 60/75 C or 75 C copper(cu)wire only. V Relevant for North America for devices certified for hazardous locations: ower, input and output (I/O) wiring must be in accordance with Class I, Division wiring methods [Article 50-(b) of the National Electrical Code, NFA 70] and in accordance with the authority having jurisdiction. U Shielding ground The shielding ground of the connectable twisted pairs lines is connected to the front panel as a conductor. V Beware of possible short circuits when connecting a cable section with conductive shielding braiding. Release.0 0/06
5 U Housing Only technicians authorized by Hirschmann are permitted to open the housing. The device is grounded via the separated ground screw. It is located on the left under the front panel. V Make sure that the electrical installation meets local or nationally applicable safety regulations. V The ventilation slits must not be covered to ensure free air circulation. V The distance to the ventilation slots of the housing has to be a minimum of 0 cm. V Never insert pointed objects (thin screwdrivers, wires, etc.) into the inside of the subrack! Failure to observe this point may result in injuries caused by electric shocks. V The device has to be mounted in an upright position. V If installed in a living area or office environment, the device must be operated exclusively in switch cabinets with fire protection characteristics according to EN U Environment The device may only be operated in the listed maximum surrounding air temperature range at the listed relative air humidity range (non-condensing). V The installation location is to be selected so as to ensure compliance with the climatic limits listed in the Technical Data. V To be used in a ollution Degree listed in the Technical Data. U Qualification requirements for personnel Qualified personnel as understood in this manual and the warning signs, are persons who are familiar with the setup, assembly, startup, and operation of this product and are appropriately qualified for their job. This includes, for example, those persons who have been: D trained or directed or authorized to switch on and off, to ground and to label power circuits and devices or systems in accordance with current safety engineering standards; D trained or directed in the care and use of appropriate safety equipment in accordance with the current standards of safety engineering; D trained in providing first aid. U General Safety Instructions This device is electrically operated. Adhere strictly to the safety requirements relating to voltages applied to the device as described in the operating instructions! Failure to observe the information given in the warnings could result in serious injury and/or major damage. Release.0 0/06 5
6 V Only personnel that have received appropriate training should operate this device or work in its immediate vicinity. The personnel must be fully familiar with all of the warnings and maintenance measures in these operating instructions. V Correct transport, storage, and assembly as well as careful operation and maintenance are essential in ensuring safe and reliable operation of this device. V Only use umdamaged parts! V These products are only to be used in the manner indicated in this version of the manual. V Any work that may have to be performed on the electrical installation should be performed by fully qualified technicians only. Warning! LED- or LASER components according to IEC 605- (00): CLASS LASER RODUCT. LIGHT EMITTING DIODE - CLASS LED RODUCT. Warning LED LIGHT DO NOT STARE INTO THE BEAM OR VIEW DIRECTLY WITH OTICAL INSTRUMENTS (e.g. lens, microscope). Failure to observe this warning within a distance of 00 mm can endanger your eyes. Light is emitted from the optical connections or from the ends of the optical fibers that are connected to them. Light Emitting Diode CLASS M, Wave length 650 nm, ower < mw, according to IEC/CEI 605-:00-0. U National and international safety regulations V Make sure that the electrical installation meets local or nationally applicable safety regulations. U Note on the CE marking The devices comply with the regulations contained in the following European directives: 9/6/EEC Directive of the council for standardizing the regulations of member states on electromagnetic compatibility (changed by RL 9/6/EEC, 9/ /EEC and 9/6/EEC). In accordance with the above-named EU directives, the EU conformity declaration will be at the disposal of the relevant authorities at the following address: 6 Release.0 0/06
7 Hirschmann Automation and Control GmbH Stuttgarter Straße 5-5 D-765 Neckartenzlingen Germany hone The product can be used in living areas (living area, place of business, small business) and in industrial areas. D Interference immunity: EN :00 D Emitted interference: EN 550:99 + A A 00, Class A Warning! This is a class A device. This device can cause interference in living areas, and in this case the operator may be required to take appropriate measures. The assembly guidelines provided in these instructions must be strictly adhered to in order to observe the EMC value limits. U FCC note: Appropriate testing has established that this device fulfills the requirements of a class A digital device in line with part 5 of the FCC regulations. These requirements are designed to provide sufficient protection against interference where the device is being used in a business environment. The device creates and uses high frequencies and can radiate same, and if it is not installed and used in accordance with this operating manual, it can cause radio transmission interference. The use of this device in a living area can also cause interference, and in this case the user is obliged to cover the costs of removing the interference. U Recycling note: After usage, this product must be disposed of properly as electronic waste in accordance with the current disposal regulations of your county / state / country. Release.0 0/06 7
8 About this manual The following manuals are included as DF files on the enclosed CD ROM: D User manual Installation D User manual Basic configuration D User manual Redundancy configuration D Reference manual Web-based Interface and D Reference manual Command Line Interface If you use Network Management Software HiVision you have further opportunities to: D have an event logbook. D configure the System Location and System Name. D configure the network address range and SNM parameters. D save the configuration on the Switch. D simultaneous configuration of several Switches. D configure the relevant ports to be displayed red if there is no link state. Legend The commendations used in this manual have the following meanings: D V U Listing Work step Subheading Release.0 0/06
9 Device description The Open Rail Family offers you a variety of more than 50 switch models. You set up your own switch according to your requirements regarding the number of ports, transmission speed, media type, connector type, temperature range, certifications and software variant. The devices are designed for the special requirements of industrial automation. They meet the relevant industry standards, provide very high operational reliability, even under extreme conditions, and also long-term reliability and flexibility. The devices operate without fans and have a redundant voltage supply. The switches are very quickly mounted by snapping them onto a hat rail. The HIER-Ring redundancy concept enables you to quickly carry out a reconfiguration, and also a simple configuration with only one additional connection. The diagnosis display and the display of the operating parameters and I address information field provide a quick overview. It can be easily managed via a Web browser, via Telnet, with a management software product (such as F) or locally on the switch (V. interface). The allows you to construct switched industrial ETHERNET networks that conform to the IEEE 0. and 0.u standards using copper wires or optical fibers in a bus or ring topology. You can connect terminal devices and other infrastructure components via twisted pair cables, multi-mode LWL and single-mode LWL. The twisted pair ports support autocrossing, autonegotiation and autopolarity. Depending on the software you choose, the devices provide you with a large range of functions: D Redundancy functions (Rapid Spanning Tree, Redundant Ring Structure, HIER-Ring, Redundant Coupling, Link Aggregation, Redundant ower Supply) D rotection from unauthorized access D Synchronized system time in the network D Network load control D Function diagnosis D Diagnostics (hardware self-testing) D Reset D riority D VLAN D Topology recognition D Web-based interface D Command Line Interface - CLI D SNM Release.0 0/06 9
10 D 0.x port authentication D Real Time Clock (rofessional software variant) The addition, to the Open Rail range, of the MICE range of switches, the MACH range of backbone switches, the BAT wireless transmission system, the EAGLE security system, and products for the LI control room, provides continuous communication across all levels of the company.. Description of the device variants The devices differ with regard to the range of software functions, the number of interfaces, and the media type for connecting segments. D The RS0-... device variants are rail switches with,, 6 or * 0/00 Mbit Ethernet ports. You can choose the media for ports and. The other, 6, or ports are 0/00 Mbit Ethernet ports with twisted pair connections via RJ5 connectors. D In the RS0-... device variants, ports and are gigabit ports (000 Mbit Ethernet, FX or TX). You can choose the media for ports and. The other, 6 or ports are 0/00 Mbit Ethernet ports with twisted pair connections with RJ5 connectors. The devices also provide you with the following options for selecting the variant you desire: D Temperature range: D Standard (0 C to 60 C) or D Extended (-0 C to +70 C) without conformal coating D Extended (-0 C to +70 C) with conformal coating D Certifications: D CE, UL D CE, UL, German Lloyd (GL), IEC 650 Declaration (Sub Station), IEEE 6 (Sub Station), EN 50- Railway (along track) D CE, UL, German Lloyd (GL), IEC 650 Declaration (Sub Station), IEEE 6 (Sub Station), EN 50- Railway (along track), EN 5055 Declaration (Railway) and ATEX 00a (Hazardous Location) D Software variant: Enhanced or rofessional The devices comply with the specifications of the standards: ISO/IEC 0-u 00BASE-TX/-000BASE-T, ISO/IEC 0-00BASE-FX and ISO/IEC 0-000BASE-SX/LX. 0 Release.0 0/06
11 .. combination options The product designation of your device is made from combining the desired product characteristics in accordance with the following table. The short designation is in column. osition Attribute Ident. Feature to roduct RS0 Rail switch without gigabit ports RS0 Rail Switch with gigabit ports 5 - (hyphen) - 6 to 7 Number of 0/00 0 * 0/00 Mbit Ethernet Mbit ports 0 * 0/00 Mbit Ethernet 6 6 * 0/00 Mbit Ethernet * 0/00 Mbit Ethernet and 9 Number of * 000 Mbit Ethernet Mbit ports 0 * 000 Mbit Ethernet (without port devices) 0 and ort (ring port) T Twisted pair TX, RJ5 M Multimode FX, DSC, 0/00 Mbit M Multimode FX, ST, 0/00 Mbit S Singlemode FX, DSC, 0/00 Mbit L Singlemode longhaul, DSC, 0/00 Mbit O6 SF slot, 000 Mbit and ort (ring port) T Twisted pair TX, RJ5 M Multimode FX, DSC, 0/00 Mbit M Multimode FX, ST, 0/00 Mbit S Singlemode FX, DSC, 0/00 Mbit L Singlemode longhaul, DSC, 0/00 Mbit O6 SF slot, 000 Mbit Temperature range S Standard 0 C to +60 C T Extended -0 C to +70 C E Extended -0 C to +70 C, conformal coating 5 Voltage range D 9,6 VDC to 60 VDC or VAC to 0 VAC 6 Specifications A CE, UL H CE, UL, GL, railway (along track), sub station B CE, UL, GL, railway (along track), sub station, hazardous location (ATEX), railway (train) 7 Software variant E Enhanced rofessional Table : Combination options of the device version Release.0 0/06
12 U Example: RS0-00O6TSE RS0-0 0 O6 T S D A E RS0-: Rail Switch with gigabit ports 0: x 00 Mbit Ethernet ports 0: x 000 Mbit Ethernet ports O6: ort = SF slot, 000 Mbit T: ort = twisted pair TX, RJ5 connector, 000 Mbit S: Temperature range standard (0 C to 60 C) D: Voltage range 9,6 VDC to 60 VDC or VAC to 0 VAC A: Specifications CE and UL E: Software version enhanced.. RS0-... number of ports and media ort + port, connection (at your own option) T: twisted pair TX, RJ5, 0/00 Mbit M: multimode FX, DSC, 00 Mbit M: multimode FX, ST, 00 Mbit S: singlemode FX, DSC, 00 Mbit L: SM longhaul, FX, DSC, 00 Mbit +V () 0V 0V RS0 +V () 6-pin pluggable terminal block LED display elements -pin DI switch +V () 0V 0V RS0 +V () +V () 0V 0V RS0 +V () I-ADDRESS V. interface V. access external management I address field I-ADDRESS V. I-ADDRESS V. MAC address field orts in line with 0/00BASE-T(X) (RJ5 connectors) RS0-000MT RS0-000MM RS0-000TT Fig. : Models with * 0/00 MBit ports (RS ) Release.0 0/06
13 V() 0V 0V +V() V V() 0V 0V +V() V. 5 6 ort + ort, Anschluß nach Wahl T: Twisted air TX, RJ5, 0/00 Mbit M: Multimode FX, DSC, 00 Mbit M: Multimode FX, ST, 00 Mbit S: Singlemode FX, DSC, 00 Mbit L: SM Longhaul, FX, DSC, 00 Mbit +V() 0V 0V RS0 +V() steckbarer Klemmblock 6polig LED Anzeigeelemente poliger DI-Schalter I-ADDRESS V. Schnittstelle V.-Zugang externes Management I-ADDRESS RS0 +V() 0V 0V +V() V. 5 6 RS0 +V() 0V 0V +V() I-ADDRESS V I-Adressfeld MAC-Adressfeld orts nach 0/00BASE-T(X) (RJ5-Anschlüsse) 7 7 RS0-000TT RS0-000MT RS0-000MM Fig. : Models with * 0/00 MBit ports (RS ) ort + port, connection (at your own option) T: twisted pair TX, RJ5, 0/00 Mbit M: multimode FX, DSC, 00 Mbit M: multimode FX, ST, 00 Mbit S: singlemode FX, DSC, 00 Mbit L: SM longhaul, FX, DSC, 00 Mbit +V() 0V 0V RS0 +V() 6-pin pluggable terminal block LED display elements -pin DI switch I-ADDRESS V. interface V. access external management I-ADDRESS RS0 I-ADDRESS RS I address field MAC address field orts in line with 0/00BASE-T(X) (RJ5 connectors) RS0-600TT RS0-600MT RS0-600MM Fig. : Models with 6 * 0/00 MBit ports (RS ) Release.0 0/06
14 +V() 0V 0V +V() V V() 0V 0V +V() V. 9 0 ort + port, connection (at your own option) T: twisted pair TX, RJ5, 0/00 Mbit M: multimode FX, DSC, 00 Mbit M: multimode FX, ST, 00 Mbit S: singlemode FX, DSC, 00 Mbit L: SM longhaul, FX, DSC, 00 Mbit 5 7 +V() 0V 0V 6 RS0 +V() 6-pin pluggable terminal block LED display elements -pin DI switch I-ADDRESS 9 0 V. interface V. access external management I-ADDRESS RS0 I-ADDRESS RS I address field MAC address field orts in line with 0/00BASE-T(X) (RJ5 connectors) RS0-00TT RS0-00MT RS0-00MM Fig. : Models with * 0/00 MBit ports (RS ).. RS0-... number of ports and media ort + port, connection (at your own option) T: twisted pair TX, RJ5, 0/00/000 Mbit O6: FX, SF slot, 000 Mbit +V() 0V 0V RS0 +V() 6-pin pluggable terminal block LED display elements -pin DI switch +V() 0V 0V RS0 +V() +V() 0V 0V RS0 +V() I-ADDRESS V. interface V. access external management I address field I-ADDRESS V I-ADDRESS V MAC address field orts in line with 0/00BASE-T(X) (RJ5 connectors) RS0-00O6T RS0-00O6O6 RS0-00TT Fig. 5: Models with * 000 Mbit ports and * 0/00 MBit ports (RS ) Release.0 0/06
15 V() 0V 0V +V() V RS0 +V() 0V 0V +V() V V() 0V 0V +V() V. 5 7 RS0 +V() 0V 0V +V() V ort + port, connection (at your own option) T: twisted pair TX, RJ5, 0/00/000 Mbit O6: FX, SF slot, 000 Mbit +V() 0V 0V RS0 +V() 6-pin pluggable terminal block LED display elements -pin DI switch I-ADDRESS V. interface V. access external management I address field I-ADDRESS RS0 I-ADDRESS RS MAC address field orts in line with 0/00BASE-T(X) (RJ5 connectors) RS0-60O6T RS0-60O6O6 RS0-60TT Fig. 6: Models with * 000 Mbit ports and 6 * 0/00 MBit ports (RS ) ort + port, connection (at your own option) T: twisted pair TX, RJ5, 0/00/000 Mbit O6: FX, SF slot, 000 Mbit 5 7 +V() 0V 0V 6 RS0 +V() 6-pin pluggable terminal block LED display elements -pin DI switch I-ADDRESS 9 0 V. 9 0 interface V. access external management I address field I-ADDRESS I-ADDRESS MAC address field orts in line with 0/00BASE-T(X) (RJ5 connectors) RS0-0O6T RS0-0O6O6 RS0-0TT... Fig. 7: Models with * 000 Mbit ports and * 0/00 MBit ports (RS0-0...) Release.0 0/06 5
16 Assembly and startup procedure The device has been developed for practical application in a harsh industrial environment. Accordingly, the installation process has been kept simple. On delivery, the device is ready for operation. The following procedure is appropriate for assembly: D Unpacking and checking D Filling out the labeling field D Adjusting the DI switch settings D Connecting the terminal block for supply voltage and signal contact D Fitting the device on the ISO/DIN rail, grounding D Fitting the terminal block, startup procedure D Connecting the data lines. Device installation.. Unpacking and checking V Check whether the package was delivered complete see Scope of delivery on page. V Check the individual parts for transport damage... Filling out the labeling field The information field for the I address on the front of the device helps you to structure your network installation clearly. RS0 I address of the device (labeling field) +V() 0V 0V +V() MAC address of the device (label) I-ADDRESS V RS0 with ports Fig. : Labeling field for the I address of the device 6 Release.0 0/06
17 .. Adjusting the DI switch settings The -pin DI switch on the front panel of the device offers you the following possibilities: switch switch Ring coupling Ring redundancy Redundancy Manager Ring port Control port OFF OFF on off off + OFF on off on + OFF on on off + off off off Coupling port Fig. 9: -pin DI switch V Check whether the switch default settings match your requirements before starting the device... Connecting the terminal block for supply voltage and signal contact The supply voltage and the signal contacts are connected via a 6-pin terminal block with snap locking. U Supply voltage The supply voltage can be connected redundantly. Both inputs are uncoupled. With redundant supply, the transformer supplies the device alone with the higher output voltage. The supply voltage is electrically isolated from the housing. You can choose between DC or AC voltage when connecting the supply voltage. You use the +V and 0V pins to connect the AC voltage (see Fig. 0).. +V() 0V 0V +V() +V() 0V 0V +V() , VDC 9, VDC DC voltage G G...0 VAC...0 VAC AC voltage Fig. 0: Connection of the supply voltage on the 6-pin terminal block Release.0 0/06 7
18 Note: With non-redundant supply of the mains voltage, the device reports a power failure. You can prevent this message by applying the supply voltage over the two inputs or by changing the configuration via management. U Signal contact D The signal contact ("", pin assignment of the terminal block see Fig. Connection of the supply voltage on the 6-pin terminal block on page 7) monitors proper functioning of the device, thus enabling remote diagnostics. You can specify the type of function monitoring in the Management. D You can also use the Management to switch the signal contact manually and thus control external devices. A break in contact is reported via the potential-free signal contact (relay contact, closed circuit): D The failure of at least one of the two supply voltages (supply voltage or < 9,6 V). D A continuous malfunction in the device (internal. VDC voltage). D The defective link status of at least one port. With the device, the indication of link status can be masked by the management for each port. Link status is not monitored in the delivery condition. D The loss of Redundancy guarantee. D Error during self-test. The following conditions are reported in stand-by mode D Control cable disrupted D Control cable shorted D artner device is in stand-by mode The following conditions are reported in normal mode: D Control cable shorted D artner device is in normal mode The following condition is reported in mode additionally: D Ring redundancy guaranteed. Ring redundancy is not monitored in the delivery condition. V ull the terminal blocks off the device and connect the power supply and signal lines. Release.0 0/06
19 ..5 Fitting the device on the ISO/DIN rail, grounding V You mount the device on a 5 mm hat rail according to DIN EN Attach the upper snap-in guide of the device into the hat rail and press it down against the hat rail until it snaps into place. Note: The shielding ground of the connectable twisted pair lines is connected to the front panel as a conductor. Fig. : Assembly U Ground The front panel of the device is grounded via a separate ground screw...6 Fitting the terminal block, startup procedure V Mount the terminal block for the supply voltage and the signal contact on the front of the device. Make sure that the snap lock snaps into place. By connecting the supply voltage at the terminal block, you start the operation of the device...7 Connecting the data lines You can connect terminal devices and other segments at the ports of the device via twisted pair cables and LWL cables. U 0/00 Mbit/s twisted pair connection 0/00 Mbit/s ports (R5 socket) enable the connection of terminal devices or independent network segments in compliance with the IEEE 0. 00BASE-TX / 0BASE-T standards. These ports support: D autonegotiation D autopolarity D autocrossing (when autonegotiation is switched on) Release.0 0/06 9
20 D 00 Mbit/s half duplex mode, 00 Mbit/s full duplex mode D 0 Mbit/s half duplex mode, 0 Mbit/s full duplex mode State on delivery: autonegotiation is activated with exception of the HIER-Ring ports: 00 Mbit/s full duplex. The socket housings are electrically connected to the lower covering. Fig. : in assignment of a T/TX interface in MDI-X mode, RJ5 socket U 0/00/000 Mbit/s twisted pair connection 000 Mbit/s twisted pair connection 000 MBit/s twisted pair ports (RJ5 sockets) enable the connection of terminal devices or independent network segments in compliance with the IEEE 0-, 000 Edition 000BASE-T standard. These ports support: D autonegotiation D autopolarity D autocrossing (when autonegotiation is switched on) D 000 Mbit/s full duplex D 00 Mbit/s half duplex, 00 Mbit/s full duplex, D 0 Mbit/s half duplex, 0 Mbit/s full duplex. State on delivery: autonegotiation. The socket housing is electrically connected to the front panel. The pin assignment corresponds to MDI-X. n.c. in n.c. in 7 TD- in 6 n.c. in 5 n.c. in TD+ in RD- in RD+ in BI_DC- BI_DC+ BI_- BI_DD- BI_DD+ BI_+ BI_DB- BI_DB+ in in 7 in 6 in 5 in in in in Fig. : in assignment of a 000 MBit/s twisted pair interface U 00 Mbit/s F/O connection 00 MBit/s F/O ports (ST- or DSC) enable the connection of terminal devices or independent network segments in compliance with the IEEE 0. 00BASE-FX standard. These ports support: D full and half duplex mode State on delivery: full duplex. Note: Make sure, that you conncet LH ports only to LH ports, SM ports only to SM ports and MM ports only to MM ports. 0 Release.0 0/06
21 U Gbit/s F/O connection Gbit/s F/O ports (DSC sockets) enable the connection of terminal devices or independent network segments in compliance with the IEEE (ISO/IEC 0-:000) 000BASE-SX or 000BASE-LX standard. These ports support: D autonegotiation, D full duplex mode State on delivery: autonegotiation. Note: Make sure, that you conncet LH ports only to LH ports, SX ports only to SX ports and LX ports only to LX ports. V Connect the data lines according to your requirements.. Displays After applying the operating voltage, the software starts and initializes itself. The device then performs a selftest. Various LEDs light up in the process. The process lasts approximately 60 seconds. Device status ort status U Device status These LED's provide information about conditions which affect the operation of the whole device. - ower (green/yellow LED) Meaning lit green both supply voltages on lit yellow only one supply voltage is on ( or ) not lit supply voltage is too low Error ) Meaning lit red the signal contact is open, i.e. it reports an error not lit the signal contact is closed, i.e. it does not report an error Release.0 0/06
22 - Redundancy Manager (green/yellow LED) lit green lit yellow not lit flashes green lit green not lit Meaning function active, redundant port not active function active, redundant port active function not active Incorrect configuration of HIER-Ring (e.g. ring not connected to ring port Meaning opeartion active operation not active ) If the manual adjustment is active on the signal contact, then the error display is independent of the signal contact setting. U ort status The green and yellow LEDs on the specific ports display port-related information. During the boot phase, the status of the boot procedure is displayed with these LEDs:. (Link status, green LED) not lit lit green flashes green ( time per second) flashes green ( times per second) (Data, yellow LED), not lit flashes yellow Meaning no valid connection valid connection port is switched to stand-by port is disabled Meaning no data reception at the specific port data reception at the specific port. Carrying out basic settings I addresses must be entered when the device is installed for the first time. The device provides 6 options for configuring the I addresses: D Entry via the V. connection. D Entry by HiDiscovery protocol D Configuration via BOOT D Configuration via DHC D Configuration via DHC Option D The AutoConfiguration Adapter Release.0 0/06
23 U State of delivery D I address: The device looks for the I address using DHC D assword for management: user, password: public (read only) admin, password: private (read and write) D V. data rate: baud D Ring redundancy: on Ring ports on 00 Mbit full duplex or 000 Mbit autonegotiation D Ethernet ports: Link status is not evaluated (signal contact) D Optical 00 Mbit ports: 00 Mbit full duplex All other ports: autonegotiation D Redundancy manager switched off (DI switch : OFF) D Stand-by coupling off (DI switch Stand-by: OFF) ort = control port, port = coupling port for red. ring coupling U interface The socket offers an interface for the local connection of an Auto- Configuration Adapter ACA -. It is a device for saving/loading the configuration and for loading the software. in number Signal name VCC - Data + Data Ground U V. interface (external management) A serial interface is provided on the RJ socket (V. interface) for the local connection of an external management station (VT00 terminal or C with appropriate terminal emulation) or an AutoConfiguration Adapter ACA. This makes it possible to establish a connection to the Command Line Interface CLI and to the system monitor. VT 00 terminal settings Speed Data Stopbit Handshake arity baud bit bit off none The socket housing is electrically connected to the front cover of the device. The V. interface is electrically connected to the supply voltage. Release.0 0/06
24 in 6 in RJ DB9 in 5 in in CTS n.c. TX GND RX RTS Fig. : in assignment of the V interface Note: You will find the order number for the terminal cable, which is ordered separately, in the chapter Technical data on page 5. You will find a detailed description of the configuration in the Basic Configuration User Manual on the CD-ROM.. Disassembling the device V To take the device off the ISO/DIN rail, insert a screwdriver horizontally under the housing into the locking slide, pull it (without tipping the screwdriver) downwards and lift the device upwards. Release.0 0/06
25 Technical data General data Dimensions W x H x D Weight RS RS / RS RS / RS RS / RS RS RS / RS RS / RS RS / RS mm x mm x mm 7 mm x mm x mm 0 mm x mm x mm 0 mm x mm x mm 00 g 0 g 600 g 650 g Voltage supply Operating voltage 9,6 to 60 V DC safety extra-low voltage (SELV/ ELV), redundant inputs decoupled. Relevant for North America: Nec Class power source 5 A maximum. or to 0 V AC Overload current non-changeable fuse protection at input Isolation voltage between operating voltage and housing 00 V Surrounding Storage temperature (surrounding air) Humidity Atmospheric pressure Operating temperature Extended Standard ollution degree rotection types Laser protection rotection types Standard: -0 C to +70 C Extended: -0 C to +5 C 0% to 95% (non condensing) up to.000 m (795 ha), higher altitudes on demand 0 C to +60 C -0 C to +70 C Class conforming to EN 605- (00) I 0 Release.0 0/06 5
26 EMV and stability EMV interference proof EN EN EN EN Discharge of static electricity Contact discharge: test level Air discharge: test level Electromagnetic fields Test level (0-000 MHz) Fast transients (burst), test level, x - ower line - Data line Surge voltage - ower line, line/line: test level - ower line, line/earth: test level - Data line: test level ) roduct code A: Certification = CE, UL roduct code B: Certification = CE, UL, GL, Railway, Sub Station, see Combination options of the device version on page A ) B ) kv KV kv 5 kv 0 V/m 0 V/m kv kv 0,5 kv kv kv kv kv kv kv kv EN Cable-based RF faults, test level 0 khz - 50 khz 50 khz - 0 MHz V 0 V V 0 V EN Impulse-shaped magnetic fields; test level - 00 A/m EMV emitted immunity EN 550 Class A Yes Yes FCC 7 CFR art 5 Class A Yes Yes Germanischer Lloyd Rules for Classification and Construction VI Yes art, Ed. 00 Stability Vibration IEC Test FC, testing level in line with IEC Yes Yes 6- Germanischer Lloyd Guidelines for the erformance - Yes of Type Tests art IEC 70-- Table Normal Installation in line with - Yes EN650- Shock IEC Test Ea, testing level in line with IEC Yes Yes 6- IEC 70-- Table Normal Installation in line with EN Yes 6 Release.0 0/06
27 Network size Length of a twisted pair segment 00 m approx. cat5e cable with 000BASE-TX Table : T port 0BASE-T / 00BASE-TX / 000BASE-T roduct Wave Fiber System Expansion Fiber data code length attenuation -M, -M MM 00 nm 50/5 µm 0- db 0-5 km,0 db/km, 00 MHz*km -M, -M MM 00 nm 6,5/5 µm 0- db 0- km,0 db/km, 500 MHz*km -S SM 00 nm 9/5 µm 0-6 db 0-0 km 0, db/km;,5 ps/(nm*km) -L LH 550 nm 9/5 µm 7-9 db -6 km 0, db/km; 9 ps/(nm*km) Table : F/O port 00BASE-FX roduct Wave Fiber System Expansion Fiber data code length attenuation -SX/LC MM 50 nm 50/5 µm 0-7,5 db m,0 db/km, 00 MHz*km -LX/LC MM 0 nm ) 50/5 µm 0- db m,0 db/km, 00 MHz*km -SX/LC MM 50 nm 6,5/5 µm 0-7,5 db 0-75 m, db/km, 00 MHz*km -LX/LC MM 0 nm ) 6,5/5 µm 0- db m,0 db/km, 500 MHz*km -LX/LC SM 0 nm 9/5 µm 0- db 0-0 km 0, db/km;,5 ps/(nm*km) -LH/LC LH 550 nm 9/5 µm 6- db -7 km 0,5 db/km; 9 ps/(nm*km) -LH+/LC LH 550 nm 9/5 µm 5- db 60-0 km 0,5 db/km; 9 ps/(nm*km) Table : F/O port 000BASE-FX MM = multimode SM = singlemode LH = singlemode longhaul ) with F/O adapter in line with IEEE clause (single-mode fiber offset-launch mode conditioning patch cord) Release.0 0/06 7
28 ower consumption/power output Name ower consumption ower output RS , xtx port 5. W. Btu (IT)/h RS , xfx port. xtx port 6.5 W. Btu (IT)/h RS , xfx port 7.7 W 6. Btu (IT)/h RS , xtx port 5. W. Btu (IT)/h RS , xfx port, xtx port 6.5 W. Btu (IT)/h RS , xfx port 7. W 6. Btu (IT)/h RS , xtx port 9. W. Btu (IT)/h RS , xfx port, xtx port 0.6 W 6. Btu (IT)/h RS , xfx port. W 0. Btu (IT)/h RS , xtx port. W. Btu (IT)/h RS , xfx port, xtx port. W 5. Btu (IT)/h RS , xfx port 5.5 W 5.9 Btu (IT)/h RS , xtx port.9 W 0. Btu (IT)/h RS , xfx port, xtx port.6 W 9. Btu (IT)/h RS , xfx port. W. Btu (IT)/h RS , xtx port.0 W. Btu (IT)/h RS , xfx port, xtx port.7 W. Btu (IT)/h RS , xfx port. W. Btu (IT)/h RS , xtx port 5.7 W 5.6 Btu (IT)/h RS , xfx port, xtx port 5. W 5.6 Btu (IT)/h RS , xfx port 5. W 5.6 Btu (IT)/h Scope of delivery Device RS0-... or RS0-... Scope of delivery RS0-... or RS0-... device terminal block for supply voltage and indicator contact description and operating instructions CD-ROM Order numbers/product name See table Combination options of the device version on page Release.0 0/06
29 Accessories Name Order no. Manual Basics Industrial ETHERNET and TC/I AutoConfiguration Adapter ACA AutoConfiguration Adapter ACA Terminal access cable pin terminal block (50 units) Rail ower Supply RS Rail ower Supply RS Rail ower Supply RS Netzwork management software HiVision OC server software HiOC M - SF - SX / LC M - SF - LX / LC M - SF - LH / LC M - SF - LH+ / LC Based specifications and standards EN :00 Generic standards Immunity for industrial environments EN 550:99 + A 000 Information technology equipment Radio disturbance + A-00 characteristics EN 60950:00 Safety of Information Technology Equipment (ITE) EN 6-:000 rogrammable Controllers EN 50-:000 Railway applications - EMC - emitted interference and interference immunity for signal and telecommunication systems FCC 7 CFR art 5:00 Code of Federal Regulations Germanischer Lloyd Rules for Classification and Construction VI art, Ed. 00 cul 50:99 Safety for Industrial Control Equipment cul 60 Electrical Equipment for Use in Class I and Class II, Div. and Class III Hazardous (Classified) Locations EN 5055 Declaration (Railway) EN 650- Communications networks and systems in stations IEEE 6 Standard Environment and Testing Requirements for Communication Networking Devices in Electric ower Substations Table 5: List of based specifications and standards Certified devices are marked with a certification identifier. Release.0 0/06 9
30 RFC 76 UD RFC 769 SNT RFC 7 TFT RFC 907 MIB RFC 79 I RFC 95 HTT/.0 RFC 79 ICM RFC DHC RFC 79 TC RFC DHC-Options RFC 6 AR RFC 6 IGMv RFC 95 BOOT RFC 9 MAU-MIB RFC IGMv RFC SNM Framework RFC 57 SNMv RFC SNM MD RFC 55 SMIv RFC SNM Applications RFC MIB RFC SNM USM RFC 9 Dotd RFC 5 SNM VACM RFC 5 BOOT-Extensions RFC 6 SM RFC 757 RFC 67 Dotp/Q Table 6: List of RFCs IEEE 0. D IEEE 0. D-99 IEEE 0. Q IEEE 0. Q-99 IEEE 0. w.00 IEEE Switching, GAR, GMR, Spanning Tree Media access control (MAC) bridges (includes IEEE 0.p riority and Dynamic Multicast Filtering, GAR, GMR) Tagging Virtual Bridged Local Area Networks (VLAN Tagging, GVR) Rapid Reconfiguration Ethernet Table 7: List of IEEE standards Certifications Standard cul 50 / CSA C. No. cul 60 / CSA C. No. Germanischer Lloyd MS0 / MS0 pending pending pending Table : Certifications, actual state see 0 Release.0 0/06
31 Further support U Technical questions and training courses In the event of technical queries, please talk to the Hirschmann contract partner responsible for looking after your account or directly to the Hirschmann office. You can find the addresses of our contract partners on the Internet: Our support line is also at your disposal: D Tel. +9(05) -5 D Fax +9(77) -55 Answers to Frequently Asked Questions can be found on the Hirschmann internet site U Hirschmann Competence Center In the longterm, product excellence alone is not an absolute guarantee of a successful project implementation. Comprehensive service makes a difference worldwide. In the current scenario of global competition, the Hirschmann Competence Center stands head and shoulders above the competition with its comprehensive spectrum of innovative services: D Consulting incorporates comprehensive technical advice, from system evaluation through network planning to project planning. D Training offers you an introduction to the technological fundamentals, product briefing and user training with certification. D Support ranges from commissioning through the standby service to maintenance concepts. With the Competence Center, you firmly rule out any compromise: the client-specific package leaves you free to choose the service components that you will use. Internet: Release.0 0/06
32
ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide
31007950 7/2009 ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide 7/2009 31007950.02 www.schneider-electric.com NOTICE Read these instructions carefully, and look at the equipment to become
My first Hirschmann: The SPIDER family of switches.
My first Hirschmann: The SPIDER family of switches. Large selection of entry level switches Compact design Simple rail installation Industry standard 24 V supply voltage Plug & Play gets you up and running
HARTING mcon 1000 Introduction and features
Introduction and features HARTING mcon 1000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features Supporting Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s)
User Manual. Installation Industrial ETHERNET Switch MICE MS20/MS30. MICE MS20/MS30 Release 2.0 02/06. Technical support HAC-Support@hirschmann.
User Manual Installation Industrial ETHERNET Switch MICE. MICE MS20 MICE MS30 MICE Release 2.0 02/06 Technical support [email protected] The naming of copyrighted trademarks in this manual, even
HARTING econ 3000 Introduction and features
HARTING Introduction and features HARTING es, unmanaged, for installation in control cabinets General Description Features The Fast es of the product family HARTING are suitable for industrial applications
Hirschmann Switch-Tuning: The new Gigabit OpenRail.
irschmann Switch-Tuning: The new Gigabit OpenRail. 9-port Full-Gigabit ETERNET switch For upgrading slower networks ighest levels of flexibility thanks to the SFP Designed for use in industrial environments
MACH 100. Workgroup Switches. Workgroup Switches. The new MACH100 family
The new family Workgroup Switches MACH 100 Workgroup Switches MACH 100 MACH 100 : Industrial Workgroup Switches. The quality that customers expect from Hirschmann designed for control room and light industrial
HARTING mcon 3000 Introduction and features
Introduction and features HARTING mcon 3000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features The fully managed es of the product family HARTING mcon
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
Rack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
Ha-VIS FTS 3000 Introduction and features
Ha-VIS Introduction and features Ethernet Switch Ha-VIS FTS 3100s-A 10-port Ethernet Switch with Fast Track Technology configurable via USB General Description Features The Fast Ethernet Switches of the
Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter
Industrial 10/100/BASE-T to 100/BASE-X SFP Media Converter Physical Port 1-port 10/100/BASE-T RJ45 with auto MDI / MDI-X function 1 SFP interface, 100/BASE-X dual mode (auto detection) Layer 2 Features
HARTING econ 4000 Introduction and features
HARTING econ 4000 Introduction and features HARTING econ 4000 es, unmanaged, for flat wall mounting General Description The Fast es of the product family HARTING econ 4000 are recommended for use in the
Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter
ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter
Welcome to the Hirschmann Power Zone: The new MACH1000 Substation Switches.
Welcome to the irschmann Power Zone: The new Substation Switches. Ruggedized Gigabit-ETERNET switches Total connectivity, uncompromising modular design Extended temperature range: 40 C up to + 85 C Extremely
8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide
8-port 10/100Base-TX +2-port 100Base-FX Switch User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by
ProCurve Switch 8000m (J4110A) and Switch 8000m
ProCurve Switch 4000m and Switch 8000m The ProCurve Switch 4000m and 8000m are managed modular 10/100/1000 desktop switches that provide scalable, expandable, low-cost migration to 10/100 switching for
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
ProCurve Switch 2500 Series
The ProCurve Switch 2500 series consists of low-cost, stackable, managed 24- and 12-port switches with 10/100 auto-sensing per port and 2 open transceiver slots for Gigabit or 100Base-FX. ProCurve Switches
IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction
IES-3080/3062 Series Features Industrial 8-port managed Ethernet switch Fastest Redundant Ethernet Ring: O-Ring (recovery time < 10ms over 250 units of connection) Open-Ring supports the other vendor s
HP ProCurve High-Speed Transceivers Installation Guide
HP ProCurve High-Speed Transceivers Installation Guide Introduction The HP ProCurve High-Speed Transceivers can be installed into a number of HP ProCurve networking devices to provide 100 Mbps and 1000
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
Provides one channel for Ethernet over existing
LB304A LBPS301A LBPS304A Hardened Ethernet Extender Quick Start Guide Provides one channel for Ethernet over existing voice-grade copper twisted-pair wire. copper BLACK wire. BOX Customer Support Information
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment
XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment Part of the device networking family of networkenablement products, XPress-Pro SW series
Expert Line Managed Industrial Switch with M-Ring Function 16x 10/100 Base-TX, 2x 10/100/1000Base-T (100/1000 Base-X SFP Ports)
MICROSENS Expert Line Managed Industrial Switch with M-Ring Function 16x 10/100 Base-TX, 2x 10/100/1000Base-T (100/1000 Base-X SFP Ports) General Ethernet is an international standard that has been proven
3500/22M Transient Data Interface
3500/22M Transient Data Interface Bently Nevada* Asset Condition Monitoring Description The 3500 Transient Data Interface (TDI) is the interface between the 3500 monitoring system and GE s System 1* machinery
M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide
M7250P PoE Powered Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX Installation Guide September 2009 VERSITRON, Inc. 83 Albe Drive - Suite C Newark, DE 19702 www.versitron.com www.versitron.com
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and
5-port 10/100Base-TX Industrial Switch (314500) User s Guide
5-port 10/100Base-TX Industrial Switch (314500) User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by
Gigabit Switching Ethernet Media Converters - Product User Guide
Gigabit Switching Ethernet Media Converters - Product User Guide PL0338 Issue3 Introduction These Tyco Electronics Gigabit Media Converters translate between 1000Base-T copper and 1000Base-X fiber optic
User Guide. MC100CM MC110CS Fast Ethernet Media Converter. MC111CS MC112CS WDM Fast Ethernet Media Converter
User Guide MC100CM MC110CS Fast Ethernet Media Converter MC111CS MC112CS WDM Fast Ethernet Media Converter COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark
Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11
Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and
Provides one channel for Ethernet over existing
LB304A LBPS301A LBPS304A Hardened Ethernet Extender Quick Start Guide Provides one channel for Ethernet over existing voice-grade copper twisted-pair wire. copper BLACK wire. BOX Customer Support Information
TrueAlarm Fire Alarm Systems
TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es
SHEET. Skorpion Managed Ethernet Switch Series. EISK8M Series
EISK8M Series d a t a SHEET Skorpion Managed Ethernet Switch Series The EISK8M Series offers a compact rugged managed 10/100 Mbps Ethernet switch with a choice of eight copper ports or a mix of six copper
IMC-101 Series Hardware Installation Guide
IMC-101 Series Hardware Installation Guide Moxa Industrial Media Converter Seventh Edition, August 2013 2013 Moxa Inc. All rights reserved. P/N: 1802001014025 Overview Moxa s IMC-101 industrial media converters
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
2-Pair. Managed SHDSL Ethernet Extender. User s Manual
2-Pair User s Manual 1. Quick Start Guide This quick start guide describes how to install and use the Managed SHDSL Ethernet Extender. This is the Ethernet Extender of choice to extend 10/100 Ethernet
LwLVision-USB 2.0. Installation Guide
LwLVision-USB 2.0 Installation Guide About this manual This manual has been carefully compiled and examined to the state-of-the-art. G&D neither explicitly nor implicitly takes guarantee or responsibility
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
RGPS-7084GP-P. Industrial 12-port rack-mount managed Gigabit PoE Ethernet switch with 8x10/100/1000Base-T(X) P.S.E. ports and 4x1000Base-X, SFP socket
Rack-Mount Managed Gigabit PoE v1.2 / Dec, 2011 Features Supports O-Ring (recovery time < 30ms over 250 units of connection), MSTP/RSTP/STP (IEEE 802.1s/w/D) for Ethernet Redundancy Supports Jumbo frame
IFS SP-PoE Splitter User Manual
IFS SP-PoE Splitter User Manual P/N 1069176-EN REV 1.01 ISS 01JUL10 2011 UTC Fire & Security. All rights reserved. Content Overview 2 Package contents 2 Introduction 3 Product Specifications 3 Hardware
Moxa EtherDevice Switch
Moxa EtherDevice Switch EDS-205 Hardware Installation Guide Third Edition, June 2008 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. P/N: 1802002050000 Overview The
F2400 FOM II Series Fiber Optic Modem Technical Manual
F2400 FOM II Series Fiber Optic Modem Technical Manual T1 Revision B Copyright April 2003 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A030430283T PROPRIETARY DATA All data
Industrial Ethernet Main Catalog 2008
Main Catalog 2008 Some errors can be really expensive. What good are the greatest technical inventions if you are going to save on the smallest details later? That man today is capable of great technical
Supports O-Ring (recovery time < 30ms over 250 units of connection) and MSTP(RSTP/STP compatible) for Ethernet
DGS-9168GP-AIO_S 16x10/100/1000Base-T(X) and 8x100/1000Base-X, SFP socket, LC connector bypass Features Supports O-Ring (recovery time < 30ms over 250 units of connection) and MSTP(RSTP/STP compatible)
SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program
Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves
1Industrial Ethernet Switch
Ethernet Switch DIN-Rail Managed Ethernet Switch v2.0/ Dec, 2011 IES-3080/3062 Series Features 8-port managed Ethernet switch 1 Ethernet Switch Fastest Redundant Ethernet Ring: O-Ring (recovery time
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
EtherDevice Switch EDS-726 Series
Managed Redundant EtherDevice TM Switch Solutions EtherDevice Switch EDS-726 Series 26-Port Gigabit Ethernet Switch Modular, Managed, Redundant Features Industrial Networking Capability Redundant Gigabit
MOXA EtherDevice Switch
MOXA EtherDevice Switch EDS-308/305 Hardware Installation Guide Sixth Edition, March 005 Moxa Networking Co., Ltd. Tel: +886--910-130 Fax: +886--910-131 www.moxa.com [email protected] [email protected]
ZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
FOM-5A, 6A. Asynchronous Fiber Optic Modem
FOM-5A, 6A Asynchronous Fiber Optic Modem FEATURES Asynchronous transmission at up to 19.2 kbps Transmission range up to 3 km (1.8 mi), regardless of data rate Full- or half-duplex Transfers one control
MICROSENS. Installation Switch with PoE (5x10/100Base-TX) and fiber uplink (1x100Base-FX) General. Features
Installation Switch with PoE (5x10/100Base-TX) and fiber uplink (1x100Base-FX) MICROSENS General The MICROSENS Installation Switch enables the connection of 5 end devices via twisted pair cable which also
Long Range Ethernet Extender
Long Range Ethernet Extender Model Number: EIDM-EXTEND-2 User s Manual Rev. 1.0 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road Ottawa, IL 61350 USA Phone: (815) 433-5100 General
USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)
USER MANUAL MODEL 2300M SERIES OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M) An ISO-9001 Certified Company Part# 07M2300M Doc# 077321U Rev. A Revised 4/14/03 SALES OFFICE (301) 975-1000
xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English
xepi 2 Diagnostic Unit and Configuration Interface Doc. Version 4.0 Installation Guide English Dear Customer, This "Installation Guide" will help you to install the hardware. If you have any further questions,
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A
USER S MANUAL Ethernet 10/100 Transceiver Series DL221/DL221A June 1999 ETHERNET 10/100 TRANSCEIVER INSTRUCTION MANUAL SERIES DL221/DL221A INTRODUCTION Thank you for purchasing the Radiant Communications
10/100/1000 Base-T to Gigabit Fiber Media Converter
10/100/1000 Base-T to Gigabit Fiber Media Converter Operation Manual DA-MC1101 Powered by Before Using the Product FCC Compliance Statement This device complies with part 15 of the FCC Rules. Operation
8-Port PoE Network Switch
Page 1 of 12 8-Port PoE Network Switch User s Guide Document Number 91I00-1 Rev A August, 2009 FCC Warning: Page 2 of 12 This devices has been tested and found to comply with the regulations for Class
Ethernet Switch EDS-518A Series
Managed Ethernet Switch Solutions EtherDevice Switch EDS-518A Series 16+2G-Port Gigabit Managed Redundant Ethernet Switch Highlights 2 Gigabit plus 16 fast Ethernet ports for copper and fiber Gigabit Turbo
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
MICROSENS. 45x45 Installation Switch for FTTO applications. Introduction. Characteristics
45x45 Installation Switch for FTTO applications MICROSENS Introduction Current versions of the 45x45 installation switch are usually employed in cable channels and floor boxes in FTTO (Fiber-to-the-office)
Optimux-34, Optimux-25
Data Sheet Optimux-34, Optimux-25 Up to 16 E1/T1 links and high-speed data or Ethernet traffic multiplexed into fiber optic uplink E3 copper uplink for Optimux-34 Single-mode, multimode, single-mode over
EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH
ENGLISH EMOSAFE EN-100 Product Data Sheet Network Isolators for PCB assembly November 2013 1 GENERAL DESCRIPTION The EMOSAFE EN-100 Network Isolator interrupts all galvanically conducting connections (conductors
VOICE RECORDING SYSTEM ISDN PRI / BRI
Sense Box VOICE RECORDING SYSTEM ISDN PRI / BRI / Analog SUB-SYSTEM ISDN2, ISDN30 Sense Box USER MANUAL TABLE OF CONTENTS 1. STATUTORY INFORMATION... 3 1.1 SAFETY WARNING... 3 1.2 SAFETY EXTRA LOW VOLTAGE
EDR-G903 Series. Industrial Gigabit Firewall/VPN secure router. Introduction. Specifications. Industrial Ethernet Solutions
EDR-G903 Series Industrial Gigabit Firewall/VPN secure router Router/Firewall/VPN* all-in-one High performance Gigabit copper/fiber combo port WAN redundancy function with 2 WAN interfaces and 1 LAN interface
FriendlyNET FX4000 4-Slot Modular Switch. User s Manual
FriendlyNET FX4000 4-Slot Modular Switch User s Manual 2 Asanté FriendlyNET FX4000 Table of Contents Chapter 1. Introduction 5 Key Features 5 Package Contents 5 Chapter 2. Product Overview 7 Front Panel
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M
SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M Compact Operating Instructions Legal information Qualified Personnel The product/system described in this documentation
R60 USB to CAN interface Manual (1.5 EN)
R60 USB to CAN interface Manual (1.5 EN) General information R60 USB to CAN interface Manual Version 1.5 EN, 02/2010, DOC01586 Copyright 2010 by ; all rights reserved. Eugen-Adolff-Strasse 134, D-71522
Communication Unit 560CMU05 Data sheet
RTU560 product line Communication Unit 560CMU05 Data sheet E1 10/100 MB LAN E2 10/100 MB LAN CP1, CP2 RS232C or RS485 Ethernet Controller Ethernet Controller USART Processor bus MPU ELAN520 /Flash Memory
PoE+ Extender Switch User's Manual. Rev. 2.00-60W
PoE+ Extender Switch User's Manual Rev. 2.00-60W We make no warranties with respect to this documentation and disclaim any implied warranties of merchantability, quality, or fitness for any particular
Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
How To Protect Your Deltav Controllers From Cyber Attacks
February 2015 Page 1 DeltaV Controller Firewall The provides additional security protection from for your DeltaV controllers Provides an additional level of economical cyber-protection to your DeltaV controllers
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
Perle 10/100/1000 Ethernet Media Converter Module
Perle 10/100/1000 Ethernet Media Converter Module Installation Guide C-1110-XXXXX CM-1110-XXXXX C-1110-SFP CM-1110-SFP Unmanaged Module Managed Module Unmanaged Module Managed Module P/N 5500308-21 Overview
IES-P3073GC Series. Industrial IEC 61850-3 10-port managed Ethernet switch with 7x10/100Base-T(X) and 3xGigabit combo ports, SFP socket.
DIN-Rail Managed v1.41 / Dec, 2011 IES-P3073GC Series Features Designed for power substation / Railway application and fully compliant with the requirement of IEC 61850-3 and IEEE 1613 World s fastest
Perle 10/100 Ethernet Media Converters
Perle 10/100 Ethernet Media Converters Installation Guide S-110-XXXXXX S-110-XXXXXX-XT P/N 5500302-16 (Rev B) Overview This document contains instructions necessary for the installation and operation of
DeltaV Control Network Hardware
DeltaV Distributed Control System Product Data Sheet October 2014 DeltaV Control Network Hardware The DeltaV Control Network is easy to install and maintain with the new DeltaV Smart Switches Easy to use
ProCurve Switch 1400 Series
The ProCurve Switch 1400 series provides plug-and-play simplicity for high-bandwidth connectivity. The Switch 1400 series consists of two unmanaged switches. The ProCurve Switch 1400-24G is a 24-port 10/100/1000
Alcalde # 1822 Col. Miraflores C.P. 44270 Guadalajara, Jal. México MX 01 (33) 3854-5975 y 3823-4349 USA 001 (858)-869-5401 (Chulavista, CA.
Tu Sitio de Automatización! LBJetNet385628G Introduction The LBJetNet385628G is an Industrial Modular Managed Ethernet Switch, equipped with 3 modular slot for maximum 24 10/100 Base-TX Ports or 18 100Base-FX
TK800-Series Industrial GPRS / UMTS / LTE Router
The new generation LTE with 100 Mbps LTE standard for high transmission rates and good network coverage in sparsely populated areas Dynamic Multipoint VPN GRE, L2TP, IPSec, DMVPN, OpenVPN Simple and fast
This is a product of VCCI Class B Compliance
FCC Warning This equipment has been tested and found to comply with the regulations for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog
USER MANUAL PingBrother EPIW104 managed passive poe switch & IP watchdog CONTENT Content... 2 Chapter 1... 3 1.1 Preface... 3 1.2 CE mark warning... 3 1.3 FCC warning... 4 Chapter 2... 5 2.1 Physical description...
4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Ethernet Switch Wide Temperature
4-Port 10/Mbps with + 1-Port FX Industrial Ethernet Switch Wide Temperature 15 F Fiber Optic Link Capability for Flexible Distance Extension The series equips one Base-FX port that provides more flexibility
Loop-IP6702 TDMoEthernet
Loop-IP6702 TDMoEthernet Description: Loop-IP-6702 device allows operator to transport 1 or 2 E1/T1* with timing and Ethernet traffic over IP network. This allows cost effective migration to IP network
Supports O-Ring (recovery time < 30ms over 250 units of connection) and MSTP(RSTP/STP compatible) for Ethernet
IGS-9812GP Series Industrial 20-port managed Gigabit Ethernet switch with 8x10/100/1000Base-T(X) ports and 12x100/1000Base-X, SFP socket Features Supports O-Ring (recovery time < 30ms over 250 units of
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1
BLACK BOX NETWORK SERVICES OCTOBER 2007 MT195A-T1 MT196A-E1 T1/E1 Link Extenders Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved
Manageable 10/100/1000 Mbs Ethernet Modular Multi-Media Switch
Manageable 10/100/1000 Mbs Ethernet Modular Multi-Media Switch CMX-2400G SNMP/Web Manageable, Modular Switch chassis with two GBIC slots Features: Modules with eight 10/100 UTP or LC Fiber ports: CMX-8TX,
4 Ports + 3 SFP Gigabit Smart Switch Use Manual. Ver.A0
4 Ports + 3 SFP Gigabit Smart Switch Use Manual Ver.A0 Chapter 1 Product Specification 1.1 Product Characteristics Complies with IEEE802.3,IEEE802.3u,IEEE802.3ab standards; 4 10/100/1000Mbps Auto-Negotiation
Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.
Proud Partners with MOBATime GPS or DCF 77 MOBA-NMS (Network Management Sy The new multipurpose time server for the LAN and NTP-based Distributed Time System by MOBATIME DTS 4138.timeserver The DTS 4138.timeserver
Ixia Director TM. Powerful, All-in-One Smart Filtering with Ultra-High Port Density. Efficient Monitoring Access DATA SHEET
Ixia Director TM Powerful, All-in-One Smart Filtering with Ultra-High Port Density The Ixia Director TM is a smart filtering appliance that directs traffic of interest to your monitoring tools. Now you
GEU-0822 8-Port Gigabit Switch
GEU-0822 8-Port Gigabit Switch 1 V1. 1_20150622 1. INTRODUCTION... 3 1.1 Product Briefs... 3 1.2 Product Features... 3 1.3 Hardware Introduction... 4 2. CONNECTING THE SWITCH... 5 2.1 Package Contents...
784 INTELLIGENT TRANSPORTATION SYSTEMS NETWORK DEVICES. (REV 11-17-11) (FA 1-5-12) (7-12)
784 INTELLIGENT TRANSPORTATION SYSTEMS NETWORK DEVICES. (REV 11-17-11) (FA 1-5-12) (7-12) SUBARTICLE 784-1.2.2 (of the Supplemental Specifications) is deleted and the 784-1.2.2 Networking Standards: Ensure
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
