SINEAX VK 616 Programmable Temperature Transmitter for RTD and TC inputs
|
|
- Austen Mills
- 7 years ago
- Views:
Transcription
1 SINEAX VK 66 for installation in the terminal head of a temperature sensor DIN 79, Shape B 00 II () G Application SINEAX VK 66 is a two-wire head-mounted transmitter. It is designed for measuring temperature in combination with thermocouples or resistance thermometers. Thermocouple nonlinearities are automatically compensated. The output signal is a current in the range 0 ma. The input variable and measuring range are programmed with the aid of a PC and the corresponding software. The sensor circuit is monitored for open and short-circuits and the output responds in a defined manner if one is detected. The power supply of 0 V DC is connected together with the signal by the two leads connected to the measurement output (loop powered). Fig.. Measuring transmitter SINEAX VK 66 7/7, input/output not electrically isolated. Features / Benefits Input variable and measuring range programmed using PC / Simplifies project planning and engineering, short delivery times, low stocking levels Measuring ranges Measured variables Limits Min. Max. span span Temperatures with resistance thermometers for two-, three- or four-wire connection Pt 00, IEC to 850 C 50 K 850 K Ni 00, DIN to 50 C 50 K 50 K Temperatures with thermocouples Type B, E, J, K, N, R, S, T acc. to IEC acc. to type mv 80 mv Type L and U, DIN 70 Type W5 Re/W6 Re, Type W Re/W5 Re acc. to ASTM E Standard versions The following versions are available ex stock already programmed for the basic configuration. It is only necessary to quote the Order No.: Table : Standard (non-ex) version Fig.. Measuring transmitter SINEAX VK 66 7/7, input/output electrically isolated. Optionally with or without electrical isolation between input and output / Prevents measurement errors due to potential leakage Open and short-circuit sensor circuit supervision / Defined output response should the supervision pick up Programmable with or without power supply connection Terminals with captive screws Available in type of protection Intrinsic safety EEx ia IIC T6 (see Table : Data on explosion protection ) Basic configuration: Measuring input: Pt 00 for three-wire connection Measuring range: 0 00 C Measuring output: 0 ma, linearised with temperature Open-circuit supervision: Output.6 ma Mains ripple suppression: For frequency 50 Hz Table : Version EEx ia IIC T6 Version Dimensions Order No. mm Not electrically isolated Height 6.8 mm 7 85 Electrically isolated Height 0.8 mm 7 86 Version Dimensions Order No. mm Not electrically isolated Height 6.8 mm 7 85 Electrically isolated Height 0.8 mm Please complete the Order Code according to Table : Specification and ordering information for versions with userspecific input ranges. Camille Bauer VK 66 Le 0.00
2 SINEAX VK 66 Programming A PC, the programming cable PK 60 plus ancillary cable and the programming software V 600 plus are required to program the transmitter. (Details of the programming cable and the software are to be found in the separate data sheet: PK 60 Le.) The connections between PC PK 60 SINEAX VK 66 can be seen from Fig.. The transmitter can be programmed either with or without the power supply connected. The software V 600 plus is supplied on one CD and runs under Windows 95, 98 and NT. The programming cable PK 60 adjusts the signal level between the PC and the transmitter SINEAX VK 66. The programming cable PK 60 is used for programming both standard and Ex versions. It is possible to programme the temperature transmitter installed into the hazardous area. SINEAX VK 66 Programming connector Ancillary cable Interface PK 60 Fig.. Example of the set-up for programming a SINEAX VK 66 without the power supply. For this case the switch on the interface must be set to ON. OFF ON OFF: Power supply connected to SINEAX ON: Power supply not connected to SINEAX Technical data Measuring input Temperature with resistance thermometers Measuring range limits: See table 5 Resistance types: Type Pt 00 (IEC 60 75) Type Ni 00 (DIN 760) Measuring current: 0.0 ma Standard circuit: resistance thermometer for two-, three- or four-wire connection Input resistance: R i > 0 MΩ Lead resistance: 0 Ω per lead Temperature with thermocouple Measuring range limits: See table 5 Thermocouple pairs: Type B: Pt0Rh-Pt6Rh (IEC 58) Type E: NiCr-CuNi (IEC 58) Type J: Fe-CuNi (IEC 58) Type K: NiCr-Ni (IEC 58) Type L: Fe-CuNi (DIN 70) Type N: NiCrSi-NiSi (IEC 58) Type R: PtRh-Pt (IEC 58) Type S: Pt0Rh-Pt (IEC 58) Type T: Cu-CuNi (IEC 58) Type U: Cu-CuNi (DIN 70) Type W5 Re/W6 Re (ASTM Type W Re/W5 Re E ) Standard circuit: thermocouple, internal cold junction or thermocouple, external cold junction Input resistance: Ri > 0 MΩ Cold junction : Internal or external Internal: Incorporated Pt 00 Permissible variation of the internal cold junction : ± 0.5 K to C, ± 0.5 K/0 K External: 0 60 C, programmable Measuring output Output signal I A : Standard range: External resistance (load): Residual ripple in output current: (output/powering circuit) Impressed DC current, linear with temperature...0 ma, -wire technique R ext max. [kω] Load max. [Ω] with 0 ma output < % p.p. Power supply [V] V = max. output current [ma] 0 Power supply [V] 0 6 Camille Bauer
3 Programming connector Interface: Accuracy data Serial interface Reference value: Measuring range end value Basic accuracy: Max. error ± 0.% Linearity: < 0.% Reference conditions Ambient temperature C, ± K Power supply 8 V Output burden R ext = 0 Ω Influencing factors Temperature: < ± 0.5% / 0 K Additional errors Span < 5 mv ± 0.% End value/span > 0 ± 0.% Open and short-circuit sensor circuit supervision Signalling modes: Power supply DC voltage: Output signal programmable to the value the output had immediately prior to the open or shortcircuit (Hold value) a value between and.6 ma Supply...0 V DC max. residual ripple % p.p. (supply must not fall below V) Protected against wrong polarity Installation data Dimensions: Housing: Mounting position: Electrical connections: Weight: Mounting: Standards Electromagnetic compatibility: See section Dimensional drawings Lexan 90 (polycarbonate) Flammability class V-0 acc. to UL 9, self-extinguishing, non-dripping, free of halogen Any Screw terminals with Philips heads for max..5 mm Approx. 50 g Shape B version of terminal head held by two M cheese-headed screws and two springs The standards DIN EN and DIN EN are observed Intrinsically safe: Acc. to DIN EN 50 00: Protection (acc. to IEC 59 resp. EN 60 59): Housing IP 0 Terminals IP 00 Electrical standards: Acc. to IEC 00 resp. EN 6 00 Test voltage: 500 V for electrically isolated version, applied between measuring input and output Ambient conditions Climatic rating: Climate class Z acc. to VDI/VDE 50 Commissioning temperature: 0 to + 80 C Operating temperature: NEx 5 to + 80 C Ex 5 to + 55 C/T6 5 to + 80 C/T Storage temperature: 0 to + 80 C Annual mean relative humidity: 75% Table : Data on explosion protection II () G Order Code Type of Electrical data acc. to Certificate Certificate Mounting protection Sensor input Output location of Marking instrument 66-7 EEx ia IIC T6 U o =6 V I o = 6 ma P o = 0 mw C o = 0 µf L o = 0 mh U i = 0 V I i = 60 ma P i = max. W* C i 0 L i 0 EC-type-examination Certificate Zelm 99 ATEX 000 * Ambient temperature Ex: 5 C max. 65 C (dependent on P i ) ** It is permissible for the sensor circuit to enter Zone 0, however, EN 50 8 and any applicable national standards must be observed. Within the hazardous area, zone and ** Camille Bauer
4 SINEAX VK 66 Table : Specification and ordering information (see Tables and : Standard versions) Order Code 66 - Features, Selection *SCODE no-go. Housing 7) For installation in a terminal head DIN 79, shape B Version ) Standard, not electrically isolated ) Standard, electrically isolated ) EEx ia IIC T6, not electrically isolated ) EEx ia IIC T6, electrically isolated Configuration 0) Basic configuration, programmed (Pt 00, -wire, 0 00 C) G ) Configured to order Line 0: All types with basic configuration are available as standard versions, see table and. Measuring unit ) Temperatures in C ) Temperatures in F G ) Temperatures in K G Measuring mode, input connection Thermocouple ) Internal cold junction T G ) External cold junction t K T G Resistance thermometer ) Two-wire connection, R L [Ω] R G ) Three-wire connection, R L 0 Ω/wire R ) Four-wire connection, R L 0 Ω/wire R G Line : Specify external cold junction temperature t K (in C, F or K, acc. to specification in Feature ), any value between 0 and 60 C or equivalent Line : Specify total lead resistance R L [Ω], any value between 0 and 60 Ω Table : Specification and ordering information continued on next page! Camille Bauer
5 Order Code 66 - Features, Selection *SCODE no-go 6. Sensor type / measuring range Sensor type / beginning end value of measuring range ) RTD Pt 00 Range T ) RTD Ni 00 Range GT ) RTD Pt 00 [Ω] Range GT ) RTD Ni 00 [Ω] Range GT B) TC Type B Range GR B E) TC Type E Range GR E J) TC Type J Range GR J K) TC Type K Range GR K L) TC Type L Range GR L N) TC Type N Range GR N R) TC Type R Range GR R S) TC Type S Range GR S T) TC Type T Range GR T U) TC Type U Range GR U W) TC W5-W6Re Range GR W X) TC W-W5Re Range GR X Specify measuring range in [ C], [ F] or [K]; refer to table 5 for the operating limits for each type of sensor. Lines and : Specify resistance in Ω at 0 C 7. Output characteristic 0) Standard 0 ma ) Inversely 0 ma G Open and short-circuit sensor signalling Output response for an open or short-circuit* sensor 0) Output.6 ma ) Output [ma] G ) Hold output at last value G A) No signal G.. A..... Line : Any value between and <.6 ma * The short-circuit signal is only active for the RTD measuring mode and three or four-wire connection. 9. Output time response 0) Standard setting time approx. s (rise time approx. s) ) Rise-time [s] G Line 9:,, 8, 6 or s 0. Mains ripple suppression 0) Frequency 50 Hz ) Frequency 60 Hz G Test certificate 0) Without test certificate D) Test certificate in German G..... D.. E) Test certificate in English G..... E.. Lines with letter(s) under no-go cannot be combined with preceding lines having the same letter under SCODE. Camille Bauer 5
6 SINEAX VK 66 Table 5: Temperature measuring ranges Measuring Resistance Thermocouples ranges thermometer [ C] Pt00 Ni00 B E J K L N R S T U X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Measuring range to to to to to to to to to to to to limits [ C] Span min. min. 50 K 50 K U min mv, max. 80 mv max. max. 850 K 50 K Camille Bauer 6
7 Electrical connections M ϑ ϑ ϑ Rw ϑ Rw H A TC Internal cold junction TC Cold junction with external Pt00 TC External cold junction RTD Four-wire connection RTD Three-wire connection RTD Two-wire connection R ext M A = Measuring input = Two-wire measuring output (measuring circuit) ( 0 ma signal) Power supply H = 0 V DC Table 6: Accessories and spare parts Description Order No. DSUB 9p F Interface Programming cable PK metre Ancillary cable SINEAX Type VK 66.5 metre 0 PC software V 600 plus (Download free of charge under gmc-instruments.com Operating Instructions VK 66 Bd in German 7 90 Operating Instructions VK 66 Bf in French 076 Operating Instructions VK 66 Be in English 5 Standard accessories Operating Instructions in German, French and English Type examination certificate (only for intrinsically safe explosion-proof devices) Camille Bauer 7
8 SINEAX VK 66 Dimensional drawings Ø. Ø..5 Ø Ø 5.7 Ø Ø Fig.. SINEAX VK 66-7/7, input/output not electrically isolated. Fig. 5. SINEAX VK 66-7/7, input/output electrically isolated. Printed in Switzerland Subject to change without notice Edition 0.00 Data sheet No. VK 66 Le Camille Bauer Ltd Aargauerstrasse 7 CH-560 Wohlen/Switzerland Phone Fax Telex cbm ch Camille Bauer 8
SINEAX U553 Transducer for AC Voltage
With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load
More informationJ TB/TW Temperature limiter, temperature monitor
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationAutomation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
More informationR4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
More informationH/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.
Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
More informationAPPLICATION NOTES OF SIGNAL ISOLATORS
APPLICATION NOTES OF SIGNAL ISOLATORS Summary of Topics Page 一 General Characteristics of Signal Isolator 二 The reasons and solutions about interfere 三 Comparison of supplied by loop circuit, extra power,
More information7 Lighting Technology
7 Lighting Technology Series HS6145 For use in Zone 1 and Zone 2 Comply with requirements of Fire Department standard DIN 14 462 Battery state display Deep discharge protection Open circuit monitor Light
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationFieldIT Head mounted Temperature Transmitter TF02/TF02-Ex
Data Sheet 0/-8.5 EN FieldIT Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit)
More informationTemperature Transmitters ZTT series
BT.11.13 ZT/E Transmitters ZTT series The ZTT Series transmitters accept the most commonly used temperature sensors (TC and RTD), as well as mv and slidewire feedback signals. All ZTT transmitters provide
More informationFerrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
More informationIsolating Barriers for our sensors A5S1 in Ex-areas Series D461
D46 Isolating Barriers for our sensors A5S1 in Ex-areas Series KEY FEATURES ATEX / IECEx certified, also approval for UL / CSA and EAC (Russia, Kazakhstan and Belarus Customs Union) Protection grade Ex
More informationMINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
More informationAmmeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
More informationMeasuring temperature with Resistance Temperature Detectors (RTD) (e.g., Pt100) and thermocouples
Measuring temperature with Resistance Temperature Detectors (RTD) (e.g., Pt100) and thermocouples White Paper By Prof. Dr.-Ing. Klaus Metzger In the area of physical measurement technology, temperature
More informationAmmeter / Voltmeter Series 8402, 8403, 8405, 8404
/, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,
More informationDifferential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
More informationMICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
More informationTechnical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
More informationWahl C50 Calibrator FEATURES
NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply,
More informationRosemount 333 HART Tri-Loop
Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product
More informationVario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationMagnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationVOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1
More informationRosemount 333 HART Tri-Loop
Product Data Sheet September 2014 00813-0100-4754, Rev GA Rosemount 333 HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three additional analog signals Easy to configure
More informationDigital display DA 48
Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital
More informationTLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.
More informationMeasuring Temperature withthermistors a Tutorial David Potter
NATIONAL INSTRUMENTS The Software is the Instrument Application Note 065 Measuring Temperature withthermistors a Tutorial David Potter Introduction Thermistors are thermally sensitive resistors used in
More informationSegment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.
egment Protector for Cabinet nstallation Features Assembly 4... 12 outputs Ex ic (FCO or Entity) or non-incendive (Div 2) Advanced fault isolation at the spur egment Protector in Zone 2/Div. 2 nstruments
More informationCONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
More informationPanel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
More informationTTH300 Head-mount temperature transmitter
Operating Instruction OI/TTH300-EN Rev. D TTH300 Head-mount temperature transmitter Measurement made easy Change from one to two columns Short product description Head-mount temperature transmitter for
More informationProcess modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
More informationSeries AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter
FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current
More informationRTD Temperature Probe for the Food/Pharmaceutical Industry
sales@jumo.co.uk Data Sheet 902810 Page 1/9 RTD Temperature Probe for the Food/Pharmaceutical Industry For temperatures between -50 and +250 C Protection type up to IP69 according to DIN EN 60529 (IP69K
More informationProgrammable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
More informationHSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
More informationOperating instructions. itemp PCP TMT181. Temperature head transmitter. BA100R/24/ae/06.05 51006521
Operating instructions itemp PCP TMT181 Temperature head transmitter BA100R/24/ae/06.05 51006521 Safety message TMT181 Safety message # Warning! Instructions and procedures in the operating instructions
More informationAnalog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationRedundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More informationOnline data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS
Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and
More informationProcess controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue series M5 line
BT. 2.9 M/E Process controller programmer /6 DIN - 48 x 48 mm gammadue series M line Advanced features, customizable and process adaptable High speed data aquisition and signal management. Efficent information
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationContents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
More informationTechnical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
More information2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationSEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use
s 5 146 Synco 200 Signal Converter SEZ220 With preprogrammed standard applications Freely programmable enu-driven operation Use The signal converter is for use in HVAC plant to provide minimum / maximum
More informationSafety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66
Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66 0044 37321 Contents 1 Area of applicability 4 2 General information 4 2.1 Zone 20 instruments
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationof the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series
Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series Product description Independent dimmable LED control gear Constant current LED control gear Output current adjustable between 900 1,750 ma Max. output
More informationDC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
More informationwww.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter
www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationInductive slot sensor
0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Extended temperature range Application Danger! In safety-related applications the sensor must be operated with a qualified
More informationPower Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
More informationCA12 HANDY CAL Temperature Calibrator Model 710 21
Instruction Manual CA12 HANDY CAL Temperature Calibrator Model 710 21 Thank you for purchasing the CA12 HANDY CAL. To fully utilize all of the features of this instrument, read this Instruction Manual
More informationSENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
More informationPluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
More informationPower Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN
Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit
More informationT0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
More informationSystem 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
More informationCPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips
January 2014 Description The universal CPA PC-Programmable Alarms provide on/off control, warn of unwanted process conditions, and provide emergency shutdown. Very economical, they accept a direct signal
More informationwww.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
More informationTX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationControl- and feedback head for integrated mounting on Robolux valves Type 2036
Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated
More informationEPHY-MESS GmbH phone: +49 6122 9228-0 Berta-Cramer-Ring 1 fax: +49 6122 9228-99 65205 Wiesbaden email: info@ephy-mess.de Germany
Temperature sensor PR-SPA-EX-WKF 1. Manufacturer and distributor EPHY-MESS GmbH phone: +49 6122 9228-0 Berta-Cramer-Ring 1 fax: +49 6122 9228-99 65205 Wiesbaden email: info@ephy-mess.de Germany 2. Applied
More informationProduct data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61
Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:
More informationHLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B2325-1.0 en
HLC B1... HLC F1... HLC A1... HLC B1... HLC F1... Load cells Special features -- Hermetically sealed (IP68) -- Max. capacities: 220 kg... 10 t -- Stainless steel -- Low overall height -- Meets EMC/ESD
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
More informationThroughbeam photoelectric sensors. Dimensioned drawing. Electrical connection
Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching!
More informationUM-X Field display for continous level sensors
Technical Documentation Field display for continous level sensors 10/2007 Edition: 1 Item No.: 207120 FAFNIR GmbH Bahrenfelder Str. 19 D-22765 Hamburg Telephone: +49 (0)40-39 82 07-0 Fax: +49 (0)40-3 90
More informationMeter Relays. 077 Series Analogue Meter Relays. Features. Applications
077 Series Analogue Features Monitors and controls any variable which can be converted to an A.C. or D.C. signal. Rugged, shock and vibration resistant design Indicator, relays and power unit in one housing
More informationL-LAS-TB-CL serie. laser light curtains for inline measuring tasks
L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output
More informationEntry-level Paperless Recorder with CompactFlash card and life-cycle data management
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationIsolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give
More informationHFE1600 Series 1600W 1U Hot Swap Front End Power Supplies
25.2W/in 3 power density Internal ORing MOSFET & Current Share Climate Savers Computing efficiency standards Up to 8000W in 1U rack Single and dual output 1U racks PMBus option HFE1600 Series 1600W 1U
More information3DLevelScanner II TECHNICAL DATA SHEET
TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationSEISMIC VELOCITY TRANSDUCER T1-40
SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute
More informationAPT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement
For Gauge And Absolute Pressure Measurement Application Areas: Nuclear Water & Wastewater Chemicals Petrochemical Oil & Gas Pulp & Paper Food & Beverage, Pharmaceutical Power Renewable Energy Alternate
More informationLED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series
Udriver LCAI 100W 900mA 1750mA ECO SR ECO series Product description Independent dimmable LED Driver Constant current LED Driver Output current adjustable between 900 1,750 ma Max. output power 100 W Suitable
More informationAT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products
Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution
More informationis then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
More informationAir damper actuators
4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically
More informationDifferential Charge Amplifier
Electronics Differential Type 58A... The differential charge amplifier is used for signal conversion of piezoelectric sensors with differential output. Executions Aluminum die-cast enclosure (IP64) Plastic
More informationTest equipment for temperature and its reduction
Data sheet 90.2721 Page 1/6 Test equipment for temperature and its reduction Pt100 precision RTD temperature probe Calibrated temperature measuring chain with precision display device Calibrations as service
More information