(e)(1) View, download, and transmit to 3rd party.
|
|
|
- Brian Norris
- 10 years ago
- Views:
Transcription
1 (e)(1) View, download, and transmit to 3rd party. i. EHR technology must provide patients (and their authorized representatives) with an online means to view, download, and transmit to a 3rd party the data specified below. Access to these capabilities must be through a secure channel that ensures all content is encrypted and integrity-protected in accordance with the standard for encryption and hashing algorithms specified at (f). The patient portal is already HTTP Secure. The application should check for whether the request comes from browsers that support minimum AES 256, if else have to close the connection (f) Encryption and hashing of electronic health information. Any encryption and hashing algorithm identified by the National Institute of and Technology (NIST) as an approved security function in Annex A of the FIPS Publication A. View. Electronically view in accordance with the standard adopted at (a), at a minimum, the following data: of MU2 dataset in the patient portal is marked in the tables available in the bottom of this document. s for Level A conformance of WCAG 2.0 are remaining (a) Accessibility. Standard. Web Content Accessibility Guidelines (WCAG) 2.0, Level A Conformance (incorporated by reference in ). Reference Links footer/wcag-guidelines-1208.pdf Partially Completed 1. The Common MU Data Set (which should be in their English (i.e., non-coded) representation if they associate with a vocabulary/code set). Care plan field(s), including goals and instructions is missing. (Refer Table 1: Common MU Data Set at the bottom of this document) Data Requirements.docx/ /MU2 Data Requirements.docx Partially Completed ZH Health Care, 2013 Page 1
2 2. Ambulatory setting only. Provider s name and office contact information. For remaining fields to be included in patient portal Refer Table2: Ambulatory or Inpatient Summary at the bottom of this document Partially Completed 3. Inpatient setting only. Admission and discharge dates and locations; discharge instructions; and reason(s) for hospitalization. B. Download 1. Electronically download an ambulatory summary or inpatient summary (as applicable to the EHR technology setting for which certification is requested) in human readable format or formatted according to the standard adopted at (a)(3) that includes, at a minimum, the following data (which, for the human readable version, should be in their English representation if they associate with a vocabulary/code set): Patient portal should have the option for downloading health information (that was viewed as part of the View ) in human readable format and in C-CDA format. Also one should be able to download ambulatory summary and transition care summary separately or together Reference Links Also the application should check for whether the download request comes from browsers that support minimum AES (a)(3) :. HL7 Implementation Guide for CDA Release 2: IHE Health Story Consolidation, The use of the unstructured document document-level template is prohibited. i. Ambulatory setting only. All of the data specified in paragraph (e)(1)(i)(a)(1) and (2) of this section. ii. Inpatient setting only. All of the data specified in paragraphs (e)(1)(i)(a)(1) and (3) of this section. 2. Inpatient setting only. Electronically download transition of care/referral summaries that ZH Health Care, 2013 Page 2
3 were created as a result of a transition of care (pursuant to the capability expressed in the certification criterion adopted at paragraph (b)(2) of this section). C. Transmit to third party. 1. Electronically transmit the ambulatory summary or inpatient summary (as applicable to the EHR technology setting for which certification is requested) created in paragraph (e) (1)(i)(B)(1) of this section in accordance with the standard specified in (a) Patient portal should have the option to transmit the health information through a secure channel (Patient portal have to be integrated with emrdirect) (a). : ONC Applicability Statement for Secure Health Transport EHRAStage2SecureHealthTransportCertificationandMeaningfulUse.pdf. 2. Inpatient setting only. Electronically transmit transition of care/referral summaries (as a result of a transition of care/referral) selected by the patient (or their authorized representative) in accordance with the standard specified in (a). ii. Activity history log. A. When electronic health information is viewed, downloaded, or transmitted to a third-party using the capabilities included in paragraphs (e)(1)(i)(a) through (C) of this section, the following information must be recorded and made accessible to the patient: Open EMR should keep log of every single action (with health information of a patient) (view/download and transmit) along with the date and time and the user s (who does the action) information. The same log should be made available through the patient portal. ZH Health Care, 2013 Page 3
4 (g): Synchronized clocks. The date and time recorded utilize a system clock that has been synchronized following (RFC 1305) Network Time Protocol, (incorporated by reference in ) or (RFC 5905) Network Time Protocol Version 4, (incorporated by reference in ). (g) Synchronized clocks. The date and time recorded utilize a system clock that has been synchronized following (RFC 1305) Network Time Protocol, (incorporated by reference in ) or (RFC 5905) Network Time Protocol Version 4, 1. The action(s) (i.e., view, download, transmission) that occurred; 2. The date and time each action occurred in accordance with the standard specified at (g); and 3. The user who took the action. B. EHR technology presented for certification may demonstrate compliance with paragraph (e)(1)(ii)(a) of this section if it is also certified to the certification criterion adopted at (d)(2) and the information required to be recorded in paragraph (e)(1)(ii)(a) is accessible by the patient (d)(2)(i)(A) : The OpenEMR should record actions on patient data with the following data Date and Time of Event, Patient Identification, User Identification, Access Device (optional), Type of Action (additions, deletions, changes, queries, print, copy), Identification of the Patient Data that is Accessed(optional). And also this data should be made available to patient portal (d)(2)(i)(B): In OpenEMR an additional type of log should be kept in audit log table to keep track while each time audit log is enabled or disabled While completing (d)(2)(i), the requirement in (d)(2)(ii) will be met, but should make verify the same OpenEMR is already conformance to (d)(2)(iii), (d)(2) (iv) and (d)(2)(v) ZH Health Care, 2013 Page 4
5 (d)(2) Auditable events and tamper-resistance. (i) Record actions. EHR technology must be able to: (A) Record actions related to electronic health information in accordance with the standard specified in (e)(1); (B) Record the audit log status (enabled or disabled) in accordance with the standard specified in (e)(2) unless it cannot be disabled by any user; and (C) Record the encryption status (enabled or disabled) of electronic health information locally stored on end-user devices by EHR technology in accordance with the standard specified in (e)(3) unless the EHR technology prevents electronic health information from being locally stored on end-user devices (see (d)(7) of this section). (ii) Default setting. EHR technology must be set by default to perform the capabilities specified in paragraph (d)(2)(i)(a) of this section and, where applicable, paragraphs (d)(2)(i)(b) or (d)(2)(i)(c), or both paragraphs (d)(2)(i)(b) and (C). (iii) When disabling the audit log is permitted. For each capability specified in paragraphs (d)(2)(i)(a), (B), and (C) of this section that EHR technology permits to be disabled, the ability to do so must be restricted to a limited set of identified users. (iv) Audit log protection. Actions and statuses recorded in accordance with paragraph (d)(2)(i) must not be capable of being changed, overwritten, or deleted by the EHR technology. (v) Detection. EHR technology must be able to detect whether the audit log has been altered for health information technology to protect electronic health information created, maintained, and exchanged. The Secretary adopts the following standards to protect electronic health information created, maintained, and exchanged: (e)(1) Record actions related to electronic health information, audit log status, and encryption of end-user devices. (i) The audit log must record the information specified in sections 7.2 through 7.4, 7.6, and 7.7 of the standard specified at (h) when EHR technology is in use. (ii) The date and time must be recorded in accordance with the tandard specified at (g). (e)(2) (i) The audit log must record the information specified in sections 7.2 and 7.4 of the standard specified at (h) when the audit log status is changed. (ii) The date and time each action occurs in accordance with the standard specified at (g). (e)(3)the audit log must record the information specified in sections 7.2 and 7.4 of the standard specified at (h) when the encryption status of electronic health information locally stored by EHR technology on end-user devices is changed. The date and time each action occurs in accordance with the standard specified at (g). (g) Synchronized clocks. The date and time recorded utilize a system clock that has been synchronized following (RFC 1305) Network Time Protocol, (incorporated by reference in ) or (RFC 5905) Network Time Protocol Version 4, (incorporated by reference in ). (h) Audit log content. ASTM E (Reapproved 2009), ZH Health Care, 2013 Page 5
6 2-audit-logging.html Note: : stands for forms/fields that are already available with current patient portal N : for those are not available NA : Not applicable Table 1: Common MU Data Set Common MU Data Set Consolidated CDA Patient Portal Page Template Patient Name General Header Profile/Who Sex General Header Profile/Who Date of Birth General Header Profile/Who Race General Header Profile/Stats Ethnicity General Header Profile/Stats Preferred language General Header Profile/Stats Smoking Social History Section Smoking Observation Entry Problems Problem Section Med records/ CCR/Problems Medication List Medications (entries required) Section Med records/ CCR/Medications Hospital Discharge Medications Section Medication Allergies Allergies (entries required) Section Laboratory test(s) Plan of Care Section Plan of Care Activity Observation Entry Med records/ CCR/Alerts Med records/ CCR/Results from procedures Laboratory value(s)/result(s) Results (entries required) Section Med records/ CCR/Results from procedures Vital signs height, weight, blood pressure, BMI Vital Signs Section ZH Health Care, 2013 Page 6
7 Care plan field(s), including goals and instructions Plan of Care Section N Procedures Procedures (entries required) Section Med records/ CCR/Results from procedures Care team member(s) General Header Profile/Choices Table2: Ambulatory or Inpatient Summary Data Requirements Dates and Location of Admission and Discharge- Inpatient Only Consolidated CDA Template General Header NA Patient Portal Page Discharge Instructions- Inpatient Only Hospital Discharge Instructions Section NA Provider Name and Office Contact Information- Ambulatory Only General Header Profile/Choices Reason for Hospitalization- Inpatient Only Reason for Visit and/or Chief Complaint Section(s) NA ZH Health Care, 2013 Page 7
Eligible Professional Meaningful Use Core Measures Measure 7 of 17 Stage 2 Date issued: August, 2014
Eligible Professional Meaningful Use Core Measures Measure 7 of 17 Stage 2 Date issued: August, 2014 Patient Electronic Access Objective Measure Provide patients the ability to view online, download and
STANDARDS. MEANINGFUL USE 42 CFR 495.6(j)-(m) Stage 2 Objective. 2014 Edition EHR CERTIFICATION CRITERIA 45 CFR 170.314
Use CPOE for medication, laboratory and radiology orders directly entered by any licensed healthcare professional who can enter orders into the medical record per State, local and professional guidelines.
Drummond Group, Inc. Re: Price Transparency Attestation
Drummond Group, Inc. Re: Price Transparency Attestation Organization: Criterions, LLC Product: Criterions EHR 3.0 Product Type: Complete EHR - Ambulatory Certification Number: A014E01O2Q8JEAB Certification
Stage 2 Eligible Professional Meaningful Use Core Measures Measure 15 of 17 Last Updated: August, 2015
Summary of Care Objective Measures Exclusion Table of Contents Definition of Terms Attestation Requirements Additional Information Certification and Standards Criteria Stage 2 Eligible Professional Meaningful
Certification Guidance for EHR Technology Developers Serving Health Care Providers Ineligible for Medicare and Medicaid EHR Incentive Payments
I. Background Certification Guidance for EHR Technology Developers Serving Health Care Providers Ineligible for Medicare and Medicaid EHR Incentive Payments The Medicare and Medicaid EHR Incentive Programs,
GE Healthcare Detailed Comments
GE Healthcare Detailed Comments Health Information Technology: Standards, Implementation Specifications, and Certification Criteria for Electronic Health Record Technology, 2014 Edition; Revisions to the
TEST INSTRUCTIONS FOR CROSS VENDOR EXCHANGE TABLE OF CONTENTS
TEST INSTRUCTIONS FOR CROSS VENDOR EXCHANGE TABLE OF CONTENTS Introduction...2 Meaningful Use Objectives and Measures... 3 Eligible Professionals 495.6(j)(14)... 3 Eligible Hospitals and Critical Access
Implementing Consolidated-Clinical Document Architecture (C-CDA) for Meaningful Use Stage 2. ONC Implementation and Testing Division April 5, 2013
Implementing Consolidated-Clinical Document Architecture (C-CDA) for Meaningful Use Stage 2 ONC Implementation and Testing Division April 5, 2013 Remember how healthcare data was exchanged prior to Electronic
Stage 3/2015 Edition Health IT Certification Criteria Proposed Rules Overview May 11, 2015
Stage 3/2015 Edition Health IT Certification Criteria Proposed Rules Overview May 11, 2015 Disclaimer» CMS must protect the rulemaking process and comply with the Administrative Procedure Act. During the
Using Patient Portals to Achieve Meaningful Use Stage 2
Introduction A patient portal is a secure application accessible via the Internet that allows patients to interact with their healthcare provider. The patient portal allows patients to view parts of their
Team # 1 Open EMR Certification Gap Analysis
Meaningful Use Stage 2 - Patient List Creation Patient List Objectives Patient List Measures OpenEMR Assesment Current Status Gap Action Plan Priority 1.Create a list of patients sort, access, and create
AAP Meaningful Use: Certified EHR Technology Criteria
AAP Meaningful Use: Certified EHR Technology Criteria On July 13, 2010, the US Centers for Medicare and Medicaid Services (CMS) released a Final Rule establishing the criteria with which eligible pediatricians,
Eligible Professionals please see the document: MEDITECH Prepares You for Stage 2 of Meaningful Use: Eligible Professionals.
s Preparing for Meaningful Use in 2014 MEDITECH (Updated December 2013) Professionals please see the document: MEDITECH Prepares You for Stage 2 of Meaningful Use: Professionals. Congratulations to our
A. Provisions of the Proposed Rule affecting Standards, Implementation Specifications, Certification Criteria, and Definitions
May 26, 2015 Submitted Electronically Office of the National Coordinator for Health Information Technology U.S. Department of Health and Human Services 200 Independence Avenue S.W. Suite 729-D Washington,
HL7 and Meaningful Use
HL7 and Meaningful Use Grant M. Wood HL7 Ambassador HIMSS14 2012 Health Level Seven International. All Rights Reserved. HL7 and Health Level Seven are registered trademarks of Health Level Seven International.
Stage 1 measures. The EP/eligible hospital has enabled this functionality
EMR Name/Model EMR Vendor Epic Epic Stage 1 objectives Use CPOE Use of CPOE for orders (any type) directly entered by authorizing provider (for example, MD, DO, RN, PA, NP) Stage 1 measures For EPs, CPOE
EHR Meaningful Use Guide
EHR Meaningful Use Guide for Stage I (2011) HITECH Attestation Version 2.0 Updated May/June 2014 in partnership with 1-866-866-6778 [email protected] www.medicfusion.com/platinum Medicfusion EMR
Health Information Exchange. Scalable and Affordable
Integration is Everything Health Information Exchange Scalable and Affordable Today s healthcare organizations are transforming the quality of patient care by electronically exchanging patient data at
Stage 1 measures. The EP/eligible hospital has enabled this functionality
EMR Name/Model Ingenix CareTracker - version 7 EMR Vendor Ingenix CareTracker Stage 1 objectives Use CPOE Use of CPOE for orders (any type) directly entered by authorizing provider (for example, MD, DO,
TABLE B5: STAGE 2 OBJECTIVES AND MEASURES
294 TABLE B5: STAGE 2 OBJECTIVES AND MEASURES CORE SET Improving quality, safety, efficiency, and reducing health disparities Use computerized provider order entry (CPOE) for medication, laboratory and
MEETING MEANINGFUL USE IN MICROMD -STAGE TWO- Presented by: Anna Mrvelj EMR Training Specialist
MEETING MEANINGFUL USE IN MICROMD -STAGE TWO- Presented by: Anna Mrvelj EMR Training Specialist 1 Proposed Rule On April 15, 2015 CMS Issued a new proposal rule for the Medicare and Medicaid EHR Incentive
MICROMD EMR VERSION 9.0 2014 OBJECTIVE MEASURE CALCULATIONS
MICROMD EMR VERSION 9.0 2014 OBJECTIVE MEASURE CALCULATIONS TABLE OF CONTENTS PREFACE Welcome to MicroMD EMR... i How This Guide is Organized... i Understanding Typographical Conventions... i Cross-References...
The EP/eligible hospital has enabled this functionality. At least 80% of all unique patients. seen by the EP or admitted to the
EMR Name/Model EMR Vendor Allscripts Stage 1 objectives Eligible professionals Hospitals Use CPOE Use of CPOE for orders (any type) directly entered by authorizing provider (for example, MD, DO, RN, PA,
meridianemr PATIENT PORTAL Release Notes
meridianemr PATIENT PORTAL Release Notes Click HERE to watch the video tutorials http://hitsehrtraining.com/training/memr/new%20releases/5_9/index.html Version 2.0 July 14, 2014 TABLE OF CONTENTS Contents
MicroMD EMR version 7.6
MicroMD EMR version 7.6 H I T E C H M E A S U R E C a l c u l a t i o n s MICROMD EMR HITECH MEASURE CALCULATIONS VERSION 7.6 TABLE OF CONTENTS PREFACE Welcome to MicroMD EMR... i How This Guide is Organized...
Stage 1 vs. Stage 2 Comparison Table for Eligible Hospitals and CAHs Last Updated: August, 2012
CORE OBJECTIVES (16 total) Stage 1 vs. Stage 2 Comparison Table for Eligible Hospitals and CAHs Last Updated: August, 2012 Stage 1 Objective Use CPOE for medication orders directly entered by any licensed
Office of the National Coordinator for Health IT Proposed Rule Public Comment Template
Office of the National Coordinator for Health IT Proposed Rule Public Comment Template Voluntary 2015 Edition Electronic Health Record (EHR) Certification Criteria; Interoperability Updates and Regulatory
EMR Name/ Model. meridianemr 4.2 CCHIT 2011 certified
EMR Name/ Model EMR Vendor meridianemr 4.2 CCHIT 2011 certified meridianemr, Inc Core Set of Measures Objective Stage 1 Objectives Stage 1 Measures EMR Module/ Feature 1 Use CPOE for medication orders
Meaningful Use Stage 2 Certification: A Guide for EHR Product Managers
Meaningful Use Stage 2 Certification: A Guide for EHR Product Managers Terminology Management is a foundational element to satisfying the Meaningful Use Stage 2 criteria and due to its complexity, and
Reporting Period: For Stage 2, the reporting period must be the entire Federal Fiscal Year.
Eligible Hospital and Critical Access Hospital (CAH) Attestation Worksheet for Stage 2 of the Medicare Electronic Health Record (EHR) Incentive Program The Eligible Hospital and CAH Attestation Worksheet
Meaningful Use: Stage 1 and 2 Hospitals (EH) and Providers (EP) Lindsey Mongold, MHA HIT Practice Advisor Oklahoma Foundation for Medical Quality
Meaningful Use: Stage 1 and 2 Hospitals (EH) and Providers (EP) Lindsey Mongold, MHA HIT Practice Advisor Oklahoma Foundation for Medical Quality Meaningful Use Stage 1 Focuses on Functional & Interoperability
Meaningful Use of Certified EHR Technology with My Vision Express*
Insight Software, LLC 3050 Universal Blvd Ste 120 Weston FL 33331-3528 Tel. 877-882-7456 www.myvisionexpress.com Meaningful Use of Certified EHR Technology with My Vision Express* Eligible Professional
EHR Incentive Program Stage 3 Objectives & Measures Crosswalk of Stage 3 Proposed Objectives, Measures & Corresponding Stage 2 Measures
EHR Incentive Program Stage 3 Objectives & Measures Crosswalk of Stage 3 Proposed Objectives, Measures & Corresponding Stage 2 Measures Objective 1: Protect Patient Health Information Measures: 1 (Complete
The Continuity of Care Document. Changing the Landscape of Healthcare Information Exchange
The Continuity of Care Document Changing the Landscape of Healthcare Information Exchange 1 Electronic Clinical Document Exchange Prior to the approval of the Continuity of Care Document (CCD) as an ANSI
EHR Business Process Models for Care Coordination and MU
EHR Business Process Models for Care Coordination and MU OSEHRA 2014 Conference Bethesda, MD Dr. Aneel Advani SVP Healthcare, everis Group Assoc. Prof (Adj.), Johns Hopkins 2012, everis Spain, S.L. September
Enabling Patients Decision Making Power: A Meaningful Use Outcome. Lindsey Mongold, MHA HIT Practice Advisor Oklahoma Foundation for Medical Quality
Enabling Patients Decision Making Power: A Meaningful Use Outcome Lindsey Mongold, MHA HIT Practice Advisor Oklahoma Foundation for Medical Quality Today 1. Meaningful Use (MU) 2. 2/3rds of MU relates
uently Asked NextGen Questions Share Frequently Asked uently Asked Questions Frequently Asked FAQ Pre-General Release (April-June 2014)
uestions Frequently Asked Questions Fre uestions Frequently Asked Questions Fre uestions FAQ Frequently Asked Questions Fre uestions Frequently Asked Questions Fre uestions Frequently Asked Questions Fre
Electronic Submission of Medical Documentation (esmd) CDA Digital Signatures. January 8, 2013
Electronic Submission of Medical Documentation (esmd) CDA Digital Signatures January 8, 2013 Wet Signatures Standards and legal standing Standards are based on legal precedence Non-repudiation inherent
THE STIMULUS AND STANDARDS. John D. Halamka MD
THE STIMULUS AND STANDARDS John D. Halamka MD THE ONC STRATEGY Grants - Accelerating Adoption Standards - Interim Final Rule Meaningful Use - Notice of Proposed Rulemaking Certification - Notice of Proposed
hospital s or CAH s inpatient or professional guidelines
EMR Name/ Model EMR Vendor XLEMR/XLEMR-2011-MU XLEMR Objective 1 Core Set of Measures Use CPOE for medication orders Use CPOE for medication orders More than 30% of unique patients directly entered by
ONC HIT Certification Program
ONC HIT Certification Program Test Results Summary for 2014 Edition EHR Certification Part 1: Product and Developer Information 1.1 Certified Product Information Product Name: Business Intelligence Product
SURVEY QUESTIONNAIRE 2013 AHA ANNUAL SURVEY INFORMATION TECHNOLOGY SUPPLEMENT
2013 AHA ANNUAL SURVEY INFORMATION TECHNOLOGY SUPPLEMENT SURVEY QUESTIONNAIRE This survey instrument can be used to facilitate sales, planning and marketing activities. For example, consider current and
Achieving Meaningful Use with Centricity EMR
GE Healthcare Achieving Meaningful Use with Centricity EMR Are you Ready to Report? GE Healthcare EMR Consulting CHUG Fall Conference October 2010 Achieving Meaningful Use with Centricity EMR The EMR Consulting
Test Procedure for 170.314(b)(6) Transmission of electronic laboratory tests and values/results to ambulatory providers inpatient setting only
Approved Test Procedure Version 1.3 January 16, 2013 Test Procedure for 170.314(b)(6) Transmission of electronic laboratory tests and This document describes the test procedure for evaluating conformance
TABLE 4: STAGE 2 MEANINGFUL USE OBJECTIVES AND ASSOCIATED MEASURES SORTED BY CORE AND MENU SET
CMS-0044-P 156 TABLE 4: STAGE 2 MEANINGFUL USE OBJECTIVES AND ASSOCIATED MEASURES SORTED BY CORE AND MENU SET Improving quality, safety, efficiency, and reducing health disparities Use computerized provider
EMR Name/ Model. Cerner PowerChart Ambulatory (PowerWorks ASP)
EMR Name/ Model EMR Vendor Cerner PowerChart Ambulatory (PowerWorks ASP) Cerner Corporation Core Set of Measures 1 Use CPOE for medication orders directly entered by any licensed healthcare professional
Agenda. What is Meaningful Use? Stage 2 - Meaningful Use Core Set. Stage 2 - Menu Set. Clinical Quality Measures (CQM) Clinical Considerations
AQAF Health Information Technology Forum Meaningful Use Stage 2 Clinical Considerations Marla Clinkscales & Mike Bice Alabama Regional Extension Center (ALREC) August 13, 2013 0 Agenda What is Meaningful
STAGES 1 AND 2 REQUIREMENTS FOR MEETING MEANINGFUL USE OF EHRs 1
STAGES 1 AND 2 REQUIREMENTS FOR MEETING MEANINGFUL USE OF EHRs 1 Requirement CPOE Use CPOE for medication orders directly entered by any licensed health care professional who can enter orders into the
ONC HIT Certification Program
Test Results Summary for 2014 Edition EHR Certification Version EHR-Test-144 Rev 01-Jun-2015 ONC HIT Certification Program Test Results Summary for 2014 Edition EHR Certification Part 1: Product and Developer
Medicaid EHR Incentive Program. Focus on Stage 2. Kim Davis-Allen, Outreach Coordinator [email protected]
Medicaid EHR Incentive Program Focus on Stage 2 Kim Davis-Allen, Outreach Coordinator [email protected] Understanding Participation Program Year Program Year January 1 st - December 31st. Year
Attesting for Meaningful Use Stage 2 in 2014 Customer Help Guide
Attesting for Meaningful Use Stage 2 in 2014 Customer Help Guide Table of Contents PURPOSE OF THIS DOCUMENT 4 MEANINGFUL USE STAGE 2 OVERVIEW 4 ATTESTING FOR CORE OBJECTIVES 5 CORE OBJECTIVE #1: CPOE 7
Work Product of the HITPC Meaningful Use Workgroup DRAFT Meaningful Use Stage 3 Recommendations
Improving quality and safety Clinical Decision Support Eligible Professionals (EPs)/Eligible Hospitals (EH) Core Objective: Use clinical decision support to improve performance on highpriority health conditions
Meaningful Use Stage 2 MU Audits
Meaningful Use Stage 2 MU Audits Presented by: Deb Anderson, CPHIMS HTS Consultant HTS, a division of Mountain Pacific Quality Health Foundation 1 CEHRT Certified Electronic Health Record Technology (EHR)
HIE Ready 2.0 SPECIFICATIONS MATRIX. Product Name: Version Number: Preferred Message and Trigger
HIE Ready 2.0 SPECIFICATIONS MATRIX Entity Name: Street Address: City, State, Zip: Point of Contact Name: E-mail & Phone: Alternate Contact Name: Alternate E-mail & Phone: Product Name: Version Number:
MEANINGFUL USE STAGE 1 2014 QUICK REFERENCE GUIDE
MEANINGFUL USE STAGE 1 2014 QUICK REFERENCE GUE Note: E&M codes must be recorded on the for an encounter to count towards encounterbased or unique patient based Meaningful Use measures. Visit Types and
Meaningful Use and Dentrix Enterprise Lynne Hughston Regional Manager
Meaningful Use and Dentrix Enterprise Lynne Hughston Regional Manager AUTOMATED MEASURE CALCULATION Used to gather all needed information recorded to assist the provider in attesting to Meaningful Use
HIE Services & Pricing
Services Available at No Cost Health Information Exchange Services & Pricing Package Effective: December 11, 2015 0 Interface Connection Details Services Available at No Cost HealthlinkNY Web Portal The
EHR Incentive Program Stage 2 Objectives Summary CORE OBJECTIVES (You must meet all objectives unless exclusion applies.)
EHR Incentive Program Stage 2 Objectives Summary CORE OBJECTIVES (You must meet all objectives unless exclusion applies.) TARGETING CANCER CARE Objective Objective Description Measure/Attestation Requirement
Webinar #1 Meaningful Use: Stage 1 & 2 Comparison CPS 12 & UDS 2013
New York State-Health Centered Controlled Network (NYS HCCN) Webinar #1 Meaningful Use: Stage 1 & 2 Comparison CPS 12 & UDS 2013 January 31, 2014 Ekem Merchant-Bleiberg, Director of Implementation Services
Meaningful Use Quick Guide
Meaningful Use Quick Guide Vālant EMR MEANINGFUL USE QUICK GUIDE Vālant EMR 4.00 Page 1 of 63 Table of Contents 1 ABOUT THE MEANINGFUL USE QUICK GUIDE... 4 WHO SHOULD USE IT... 5 2 INTRODUCTION... 6 WHAT
HIE Services & Pricing
Services Available at No Cost Health Information Exchange Services & Pricing Package Services Available at No Cost Services Available at No Cost HealthlinkNY Web Portal The HealthlinkNY Web Portal is available
HITECH MEANINGFUL USE
SUMMARY OF KEY PROVISIONS IN FINAL RULE FOR STAGE 2 HITECH MEANINGFUL USE Global Institute for Emerging Healthcare Practices Current as of November 28, 2012 Key Points The final rules for Stage 2 requirements
