1 Install Manual GC Standing Seam Roof System Rail Seam Mount CONTENTS I II III IV V VI VII VIII IX GENERAL MATERIALS AND TOOLS REQUIRED SYSTEM COMPONENTS INSTALLATION OF SYSTEM SYSTEM OVERVIEW MATERIALS AND WARRANTY SAFETY PRECAUTIONS AND RESPONSIBILITY OF INSTALLER ROOF AND LAYOUT PLANNING PREVENTATIVE MAINTENANCE
2 I General The GameChange Solar Standing Seam System ( Standing Seam System ) is designed to be installed on flat or sloping roofs, and is tested and engineered to withstand wind, seismic and snow load to specification when properly installed according to the installation manual. The installation manual must be precisely followed to ensure a proper installation of the Standing Seam System; otherwise there may be a decrease in the installation performance and a voiding of the warranty. II Materials and Tools Required The following tools are required for the installation of the Standing Seam System: 1.0 7/16-inch drivers, sockets and wrenches for 1/4-inch hex bolts 2.0 9/16-inch drivers, sockets and wrenches for 3/8-inch hex bolts 3.0 3/16 Allen drivers for 1/4-inch and 3/8-inch set screws 3.1 For torque settings for metals other than 22 and 24 ga steel please contact GameChange. 4.0 String Line 5.0 Roof marking tool (chalk, crayon, paint pen) 6.0 Tape Measure 7.0 Jig (sized to panel and panel and inside dimensioned panel mounting holes plus ¼ inch spacing) for spacing. Rev GameChange Standing Seam Roof System Install Manual Rail Seam Mount 2
3 III System Components The Standing Seam System contains the following parts. Separate parts list with part quantities will be available for each project. Seam Clamp (GC71) Rail (20 ft. long) (GC72) L Foot (GC73) Panel Clip Mid (GC315T) Panel Clip End (GC314T) Jumper Strap (GC120) Wire Management Hook (optional) (GC76) Hardware o Panel mounting hardware - stainless steel 1/4-20-inch x 1 3/4 to 2 ½ inch T bolts 1/4-20-inch serrated flange nuts o Rail mounting hardware 3/8-16-inch x 1 inch carriage bolt or t bolt - magnicoat steel 3/8-16-inch serrated flange nuts - magnicoat steel 1/4-20-inch x 3/4 serrated head flange bolt or ¾ inch hex bolt with lock washer - stainless steel 1/4-20-inch x 1 1/4 serrated head TEK 5 screws - magnicoat steel o Seam Clamp mounting hardware - stainless steel 3/8-24-inch x 3/4 set screw (oval tip, Allen) Rail (GC72) Jumper Straps (GC120) Jumper Strap installed on Rail L Foot (GC73) Panel Clip Mid (GC315T) Panel Clip End (GC314T) Seam Clamp (GC71) Rev GameChange Standing Seam Roof System Install Manual Rail Seam Mount 3
4 IV Installation of System Step 1: Attachment of Seam Clamps 1.0 Measure the footprint of the array according to the installer s design and site plan. 2.0 Find the edges of the array according to provided design. 3.0 Mark lines on roof for the edges of array. 4.0 Make north south spacer jig the length of the module being used + ¼-inch. 5.0 Mark the jig with the locations of the mounting holes on the back of the module. 6.0 This will establish the locations of Rails which run east-west. 7.0 Please jig so that it runs from very north-west corner to the south of that location. 8.0 Locate first seam at first mark on jig at between 4 and 15 inches to the east of that location. 9.0 Attach first Seam Clamp at this location Place seam clamp over seam Attach set screw using driver Torque to specification Attach Seam Clamps every other seam (unless directed otherwise by GameChange) to the end of the first 20 ft and 1/2 inch (length of rail plus extra space for thermal expansion) to the east, starting from the western edge of array. If there is not a Seam Clamp within 18 inches of the end of a Rail, then attach a Seam Clamp to the seam nearest the end of that Rail location. Rev GameChange Standing Seam Roof System Install Manual Rail Seam Mount 4
5 11.0 Measure starting from the west every 20 ft (length of rails) plus 1/2 inch space for thermal expansion for next Rail Attach Seam Clamp to first Seam within 18 inches Attach Seam Clamps to every other seam (unless otherwise directed by GameChange) until reach end of Rail location Attach Seam Clamps every other seam (unless directed otherwise by GameChange) to the end of the first 20 ft and 1/2 inch (length of rail plus extra space for thermal expansion) to the east, starting from the western edge of array. If there is not a Seam Clamp within 18 inches of the end of a Rail, then attach a Seam Clamp to the seam nearest the end of that Rail location Repeat 12 through 14.0 until east end of array Make sure to attach extra Seam Clamp if there is not one within 15 inches of easternmost end of Rail locations Repeat 8.0 through 16.0 from next location on jig Repeat 8.0 through 17.0 until south end of array. Rev GameChange Standing Seam Roof System Install Manual Rail Seam Mount 5
6 Step 2: Attachment of Rails 1.0 Attachment of the L Feet 1.1 Place L Foot above Seam Clamp 1.2 Attach with 1/4-20-inch serrated flange bolt or Hex bolt and lock washer 1.3 Torque to specification. 1.4 Repeat 1.1 to 1.3 until array is completed 1.0 Attachment of the Rails 1.1 Place Rail next to L Foot 1.2 Insert carriage bolt or T bolt into Rail 1.3 Put bolt through L foot 1.4 Attach with serrated flange nut 1.5 Torque to specification 1.6 Repeat 1.1 through 1.5 until Array is completed. 1.7 Rails may be cut in the field to complete array if 20 ft lengths do not enable proper completion of array. Make sure to follow Seam Clamp location instructions for all Rails regarding location of Seam Clamps within specified distances from ends of Rails. There must always be a minimum of 2 Seam Clamps used per Rail. Rev GameChange Standing Seam Roof System Install Manual Rail Seam Mount 6
7 Step 3: Wire Management 1.0 Install optional Wire Management Hooks by simply inserting T shape into 3/8-inch slot on side of rail and then rotating clockwise until Wire Management Hook locks in vertical position. 2.0 Wire Management Hooks may be inserted as needed and enable all east west wiring to be supported Step 4: Module Attachment 1.0 Attaching first End Clips with modules at start of Module Mounting Rail 1.1 Insert T bolts (or carriage bolt) into slots in Module Mounting Rails approximately 1/2 inch plus in from ends of Module Mounting Rails. 1.2 Place module on Module Mounting Rails next to T bolt (carriage bolt). 1.3 Place End Clips above panel making sure module is butted up against the tabs of the End Clips, and the End Clips are perpendicular to the angled surfaces of the Module Mounting Rails. 1.4 The T bolt heads should be rotated clockwise to lock perpendicularly to the slots, and the bolts should be perpendicular to the angled Module Mounting Rail surfaces and to the panels. If there is a groove on the threaded end of T bolt which is aligned with the T head, the groove should be perpendicular to the slot in Module Mounting Rail. 1.5 Fasten using flange nuts. (If using a drill or impact, stop after single click, then follow-up with a torque wrench and torque to specification.) 2.0 Attaching Mid Clips with modules 2.1 Insert T bolts (or carriage bolt) into slots next to modules. 2.2 Place module on Module Mounting Rails next to T bolt (carriage bolt). 2.3 Place Mid Clips above panel making sure modules are butted up against the tabs of the Mid Clips. Rev GameChange Standing Seam Roof System Install Manual Rail Seam Mount 7
8 2.4 The T bolt heads should be rotated clockwise to lock perpendicularly to the slots, and the bolts should be perpendicular to the angled Module Mounting Rail surfaces and to the panels. If there is a groove on the threaded end of T bolt which is aligned with the T head, the groove should be perpendicular to the slot in Module Mounting Rail. 2.5 Fasten using flange nuts. (If using a drill or impact, stop after single click, then follow-up with a torque wrench and torque to specification.) 3.0 Repeat 2.1 through 2.5 using Module Mid Clips until end of Module Mounting Rail is reached. Then finish the end of the Rail installation using End Clips. 4.0 Complete entire array Rev GameChange Standing Seam Roof System Install Manual Rail Seam Mount 8
9 Step 5: Grounding The modules and Module Mounting Rails are all bonded together, east and west, so that each row from one single structure as long as Grounding Strips (GC 20) or teethed Mid Clip (GC315T) are properly installed. A jumper (GameChange provided GC Jumper or WEEB-6.7) is required at one thermal expansion point between each table/set of rails (only one jumper per row of modules) on either the top or bottom rail to maintain the continuous bonding/grounding. Install WEEB-6.7 jumpers by drilling a ¼ hole and using hardware longer than 1 in length approximately 1 in from the rail edge. If using GC Jumpers, bend GC Jumper to shape as shown below to allow for a minimum of four inches of slack and install GC Jumper at same location but using 1.25 inch serrated TEK5 screws. Ultimate earth ground shall be achieved via the mounted UL 1703 Listed PV modules (as specified per corresponding installation manuals) or grounding lug (WEEBL-6.7) installed by drilling a ¼ hole and using hardware longer than 1 in length approximately 1 in from the edge of the selected Rail. GameChange recommends each one continuous bonded structure have its own bonding lead, up to 16 strings or 210 modules which ever come first may be grounded together using 8-gauge copper wire. Repeat for each 16 strings. The entire system needs to be grounded from a single point to an appropriate grounding source. **Please confirm with an electrician, as this is their responsibility** Depiction of GC Jumper Strap installation V System Overview The Standing Seam System is a simple, affordable, easily installed roof-based solar mounting system. The Standing Seam System may be installed on solar arrays of up to 100,000 solar panels each (approximately 25 MW). Maximum panel size for the system shall be 42 x 82 inches for 60 or 72 cell modules and 55 x 68 inches for 80 cell modules. VI Materials and Warranty All materials are made from non-corrosive materials, stainless steel, magnicoat steel and aluminum, with a product warranty of twenty (20) years. VII Safety Precautions and Responsibility of Installer The installer is responsible for the following: Following all instructions in this Install Manual Utilization of only qualified personnel Rev GameChange Standing Seam Roof System Install Manual Rail Seam Mount 9
10 Using only GameChange parts. Using other parts to complete the installation as substitutes may void the warranty. Making sure the roof structure can support the loading resulting from the Standing Seam System Following all safety procedures as outlined in this Install manual, both for mechanical and electrical aspects. of the solar PV array installation Following all safety instructions that are required by relevant local, regional and national organizations Materials are packaged in optimal manner to protect components. Do not un-package until time of installation. Un-packaging and restacking may cause damage to components. General safety precautions: Plan for safe practice during any installation activity with respect to hazards: from tripping, falling, lifting, repetitive stress, and any overhead or electrical hazards. When working close to building roof edges, consider protection options that reduce worker exposure to fall hazards. Refer to OSHA safety guidelines. Metal components often have sharp edges. Handle carefully! Wearing gloves is good practice. This document is not prescriptive regarding safety and does not purport to address all the safety concerns that may arise with its use. Contractors should become familiar with all applicable safety, health and regulatory requirements before beginning work. Electrical safety notice The Standing Seam System is a mechanical system and contains no live parts. Mechanical installers and electricians should coordinate in order to ensure that all personnel are aware of electrical hazards that may result once panels have been placed on the racking structure. Build rate Estimated mechanical installation rate (racks and panels per day) for an array consisting of commercialclass modules installed with the Standing Seam System and assuming a well-equipped six-person crew is on the roof and working 8 hours / day with full task interchangeability: > 200 kw / week. Field modifications Unauthorized field modification of GameChange components or assemblies may affect GameChange warranty coverage. Provide marked up drawings for GameChange s review, comment and approval prior to attempting any field modifications. Work arounds Workers laying out or installing arrays on rooftops may encounter undocumented or unexpected obstacles requiring a work around. Since PV arrays are intended to be primarily regular and repeating structures, work arounds should be noted on working drawings. When a work around affects the location of two or more modules at once, the supervisor should be advised and the work around should be evaluated and then completed in a manner that ensures that the remainder of the array is not affected. Roof surface All large flat roofs have pitch and undulation, jointed assemblies, and may also have level separations and parapets. Various roof-mounted fittings, air vent pipes and equipment such as HVAC or process equipment may also be encountered. The precise location of many rooftop details is not known since such details are installed under conditions in which the worker or contractor may have discretion regarding final location. Fire Safe Roof The Standing Seam System is to be mounted over a fire resistant roof covering rated for the application. The Standing Seam System is not meant for sloped roofs where the slope is greater than 5. All regional safety requirements should be followed when installing the Standing Seam System. All equipment/tools should be properly maintained and inspected prior to use. This installation manual is intended for use by professional installers with a working knowledge of construction principles. If the install manual is not followed completely the warranty may be voided and the solar system may not operate optimally. Rev GameChange Standing Seam Roof System Install Manual Rail Seam Mount 10
11 VIII Roof and Layout Planning Roof area must be properly inspected, repaired and made to like-new condition prior to installation to provide for a proper installation. All Debris must be removed from the roof area Structural load analysis must be obtained prior to roof installation to make sure that the roof will bear the load form the weight of the Standing Seam System. It is recommended that an inspection of the roof is conducted both prior to and after the installation of the Standing Seam System in order for the continuation of the roof warranty. Make sure to place the array in areas where there is no shading. Install the array facing as close as possible to south. Follow local building inspector setback rules, but in no case place panels closer than 5 feet to edge of building roof. IX Preventative Maintenance An annual inspection must be done to identify mechanical movement caused by any reason including thermal expansion and contraction or wind. An inspection should also be done after all storms with severe winds (over 80% of design wind speed). Inspect clips and torque settings on all hardware and make sure their installation and torque settings remain correct or are corrected. All Clips must be checked to make sure there is no gap between side of Clip and module. It is estimated that two qualified laborers should be able to properly inspect and maintain racking for approximately 1,000 panels per day. Proper preventative maintenance must be conducted or warrantee may be voided. Rev GameChange Standing Seam Roof System Install Manual Rail Seam Mount 11
RAIL FREE SOLAR ROOF MOUNT
RAIL FREE SOLAR ROOF MOUNT Utilizes EcoFasten Solar s patented technology Rock-it system Designed with the installer in mind. EcoFasten Solar specializes in solar roof attachments that are the easiest
More informationAA Solar and Sun Power Plus
AA Solar and Sun Power Plus www.aasolar.co.nz www.sunpowerplus.co.nz -1- Contents Chapter Title Page 1 General information 3 2 Safety and Installer Responsibilities 4 3 Technical Specifications 5 4 Tools
More informationASSEMBLY INSTRUCTIONS Residential Roof solutions
ASSEMBLY INSTRUCTIONS Residential Roof solutions CROSSRAIL System USA Table of contents TABLE OF CONTENTS THE COMPANY SAFETY REGULATIONS MATERIALS REQUIRED TOOLS REQUIRED ASSEMBLY TERMS AND CONDITIONS
More informationWasher, Electrical Equipment Bond. WEEB Patent Pending INSTALLATION INSTRUCTIONS. For Kinetic Solar K-Rack only
Washer, Electrical Equipment Bond WEEB Patent Pending INSTALLATION INSTRUCTIONS For Kinetic Solar K-Rack only Please read carefully before installing. Wiley Electronics recommends that the sufficient details
More informationInstallation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation
Solar Pool Heating System Installation Manual Read the complete manual before beginning the installation 1. Sizing the System Visit www.techno-solis.com to size the system using the sizing calculator.
More informationWasher, Electrical Equipment Bond WEEB
Washer, Electrical Equipment Bond WEEB INSTALLATION INSTRUCTIONS For IronRidge Light & Standard Series Rails Only Please read carefully before installing. Burndy recommends that the sufficient details
More informationInstallation Instructions
READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
More information6720616592.00-1.SD. Flat roof. Rack Mounting. Installation instructions 6 720 647 036 (2010/11) AU
6720616592.00-1.SD Flat roof Rack Mounting AU Installation instructions 2 Contents AU Contents 1 Key to symbols and safety instructions....... 3 1.1 Explanation of symbols................ 3 1.2 Safety
More informationInstallation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
More informationMounting Tripod Kit Installation Manual
Mounting Tripod Kit Installation Manual For use with Davis s wireless and cabled Vantage Pro2 weather stations, the Mounting Tripod simplifies installation. The tripod supports the Integrated Sensor Suite
More informationPV Mounting System For Crystalline Solar Module THE POWER OF ASTRONERGY
PV Mounting System For Crystalline Solar Module THE POWER OF ASTRONERGY Tile on-roof PV Mounting System Installation on tiles roof. Various quick roof hooks with different strength and structure are available.
More informationImportant: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks
TITAN pt. no.: 03 0000 0120 Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS G e n e r a t i o n V Extended
More informationPITCHED ROOF STRUCTURES
PITCHED ROOF STRUCTURES for framed and frameless photovoltaic modules Needed tools and materials: cordless screwdriver 10mm and 13mm spanners 5mm Allen key bolts, screws and tools for fixing the system
More informationSECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS
SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such
More informationPremier & Deluxe 3-Season Room Sliding Glass Door
DTSSGD-11 Premier & Deluxe 3-Season Room Sliding Glass Door Installation Instructions Screen Door Seal Left Side Track Top Track Assembly Right Side Track Right Side Trim Sliding Glass Door Sliding Screen
More informationRating when used as a weight carrying hitch without spring bars:
BOLT-TOGETHER WEIGHT DISTRIBUTING HITCH SYSTEM Rating when used as a weight distributing hitch with spring bars: Part Number 48051 4805 48053 48054 Max Tongue Weight 550 Ibs. 750 Ibs. 1000 Ibs. 1400 lbs.
More informationInstallation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011
WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers Installation Guide February, 2011 Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688 sales@pace-sci.com 1 Disclaimer The following warranty
More informationInstallation Manual. SKU# 21000 series (Base Rails) SKU# 22000 series (Overhead Racks)
Installation Manual SKU# 21000 series (Base Rails) SKU# 22000 series (Overhead Racks) Welcome to the world of TracRac! We re delighted that you have chosen TracRac, the ultimate sliding truck rack system.
More informationR O A D M A S T E R, I N C.
R O A D M A S T E R, I N C. ROADMASTER, Inc. 6110 NE 127th Ave. Vancouver, WA 98682 6 13 11 MOUNTING BRACKET KIT Cable Tab 14 12 7 15 9 Cable Tab 360-896-0407 fax 360-735-9300 www.roadmasterinc.com ITEM
More informationINSTRUCTIONS THOROUGHLY BEFORE BEGINNING***************
Bill of Materials: RAC0012 Green Wing Aerodynamic Skirt Kit Item Part Number Description Quantity 1 RMC0218 Gen 2 Trailer Skirt Roadside 1 2 RMC0219 Gen 2 Trailer Skirt Curbside 1 3 RMC0041 Trailer Skirt
More informationINSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1
City of Cotati Building Division 201 W. Sierra Ave. Cotati, CA 94931 707 665-3637 Fax 792-4604 INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1 Any PV system on a new structures should be included
More informationInstallation Instructions GOOSENECK MOUNTING KIT Chevrolet/GMC 1500/2500/3500 All except 4-door Crew-Cab
GOOSENECK MOUNTING KIT Equipment Required: Fastener Kit: F Wrenches: 3/4, 7/8, 15/16 Drill Bits: 1/4 Other Tools: Drill WARNING: Under no circumstances do we recommend exceeding the towing vehicle manufacturers
More informationOwner's Manual & Assembly Instructions
Owner's Manual & Assembly Instructions PM01 BASE KIT Model No. FDN1014 717090311 CAUTION: SOME PARTS HAVE SHARP EDGES. CARE MUST BE TAKEN WHEN HANDLING THE VARIOUS PIECES TO AVOID A MISHAP. FOR SAFETY
More informationSolar Mounting System
Xiamen Antai New Energy Tech.Co., Ltd Installation Manual Antai Rail Solar Mounting System (Flat Roof Solution) Version 1.1 Office Add: 508#, North Tower, Guangxia Building Huli Torch Hi-tech Zone, Xiamen,
More informationRPS - sales@rpssolar.com - 858 755 4505-12478 San Bruno Cove, San Diego, CA 92130
RPS - sales@rpssolar.com - 858 755 4505-2478 San Bruno Cove, San Diego, CA 9230 SWH Solar Mount Rail R-MR-SW-SR-0.5, R-MR-SW-SR-2, R-MR-SW-SR-4, R-MR-SW-SR-4B, R-MR-SW-SR-7 Part No. MR-SW-SR-0.5, MR-SW-SR-2,
More informationUSER INSTRUCTIONS AND SPECIFICATIONS for use of SAFE APPROACH STANDING SEAM ANCHOR & SAFE APPROACH METAL ROOF SCREW-DOWN ANCHOR
e) Allow the ring to slide over the end of the clevis pin and push the ring onto the clevis pin when it is centered. USER INSTRUCTIONS AND SPECIFICATIONS for use of SAFE APPROACH STANDING SEAM ANCHOR &
More informationGuidelines for Earthquake Bracing Residential Water Heaters
Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the
More informationSTEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13
STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13 (See Supplemental Instructions for trailers with heavy duty round footplates and/or Power Leveling Systems) PHONE SUPPORT
More informationInstallation Instructions: (Part # SB76880) XRC Armor Front Fender Kit
WARNING: Check with Local and State laws before installing this accessory! NOTE: Carefully read entire instructions thoroughly before attempting to install this part. Parts Included: Qty Parts Included:
More informationGuidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
More information1000-LB. TRAILER JACK OWNER S MANUAL
1000-LB. TRAILER JACK OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious
More informationOWNER S MANUAL Table Tennis Table Patent Pending
OWNER S MANUAL Table Tennis Table Patent Pending Be sure to write your model number and serial number here for future reference. You can find these numbers printed on the bottom of the table. MODEL # T8179
More informationInstallation Instructions
85-3976 rev. 05 08-13 Installation Instructions Thank you for purchasing this antisway bar kit. Please read through these instructions before installation. Rear Anti-Sway Bar Kit for Dodge Ram Pick-Up
More informationTriple Threat 3-in-1 Game Table 3 IN 1 GAME TABLE
NG0M Triple Threat 3-in- Game Table 3 IN GAME TABLE Thank 3 in Y Game Table Thank you for your purchase of our product. We work around the clock and around the globe to ensure that our products maintain
More informationSolar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual
Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual 255379 Rev. D0 1015 Printed in U.S.A. Copyright 2015 Federal Signal Corporation Limited Warranty The Alerting and Notification
More information00MK-MA0190-EN00. Mounting System ASSEMBLY INSTRUCTIONS. Universal Light system with locking brackets, for sloped roof
00MK-MA0190-EN00 Mounting System ASSEMBLY INSTRUCTIONS Universal Light system with locking brackets, for sloped roof Rev.02 November 2014 Table of contents General instructions 2 General safety instructions
More informationAssembly Instructions for the InteliTrack 3000 Rail Tracking System
Assembly Instructions for the InteliTrack 3000 Rail Tracking System InteliTrack is a trademark of Sedona Solar Technology. Sedona Solar Technology 16 April 2013 1 1. Before you begin WARNING Safety equipment
More informationSELF-STEERING AXLE TABLE OF CONTENTS
SELF-STEERING AXLE TABLE OF CONTENTS Section 1 - Introduction Section 2 - Pre-Installation Check List Section 3 - Ride Height Adjustments Section 4 - Suspension Mount Section 5 - Axle Mount Section 6 -
More informationINSTALLATION INSTRUCTIONS. 6108 Air Spring Kit 2011+ Ford F250 Single Wheel 4WD 2011+ Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113)
INSTALLATION INSTRUCTIONS 6108 Air Spring Kit 2011+ Ford F250 Single Wheel 4WD 2011+ Ford F350 Dually 4WD (2011 F350 Single Wheel 4WD use p/n 6113) Thank you for purchasing a quality Hellwig Product. PLEASE
More informationChapter 10 - Scaffolding Systems
Chapter 10 - Scaffolding Systems Contents Chapter 10 - Scaffolding Systems... 10-1 Check and Oil the Pump Jacks... 10-4 Set Pump Jack Brackets... Error! Bookmark not defined. Set Pump Jack Poles... 10-5
More informationSmall Flat Panel Lift Arm FSA-1004 and KSA-1004
I N S T A L L A T I O N I N S T R U C T I O N S Small Flat Panel Lift Arm FSA-1004 and KSA-1004 The Lift Arm is an accessory that can be used with a broad range of Small Flat Panel Displays. The allows
More informationHORIZONTAL INSTALLATION
THERMO/SOLAR Žiar s.r.o. MANUAL FOR INSTALLATION PV SUPPORTING FRAMES HORIZONTAL INSTALLATION Technical alternation reserved A1410 1 12/2014 CONTENT ORD.NO. PAGE Mounting information 3 Mounting, flat roof
More informationFTC 2015-2016 DIY Mountain Build Guide
FTC 2015-2016 DIY Mountain Build Guide Assembly Instructions Check out the DIY2015-2016 Prints and BoM for individual part details. Release 1.0 9/10/15 Page 1 This guide and Bill of Materials are for constructing
More informationToroidal Conductivity Sensor
Instruction Sheet PN 51A-/rev.C June 2012 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/rosemountanalytical.com SPECIFICATIONS Wetted Materials:
More informationINSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
More informationSolar Power System Installation Manual
Solar Power System Installation Manual Power-Save Energy Co. 3940-7 Broad St. #200 San Luis Obispo, CA 93401 866 297 7192 FOR INSTALLATION PERSONNEL Please read this manual carefully before installing
More informationTrillium 40 Axis Spring Tensioner Wire Replacement Instructions
Trillium 40 Axis Spring Tensioner Wire Replacement Instructions 1 Overview The objective is to replace the broken axis spring tensioner wire. This requires the following tasks: 1. Remove the seismometer
More informationTITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V
TITAN pt. no.: 02 0000 0143 Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS G e n e r a t i o n V Extended
More informationFRONT BUMPER INSTALLATION INSTRUCTIONS 2007-2011 DODGE / MERCEDES SPRINTER
Aluminess Products Inc 9402 Wheatlands Ct. #A Santee, CA 92071 619-449-9930 FRONT BUMPER INSTALLATION INSTRUCTIONS 2007-2011 DODGE / MERCEDES SPRINTER Please read before beginning Stainless steel hardware
More informationBUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS
BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings,
More informationPS6500 Storage Arrays Rack Mount Instructions
PS6500 Storage Arrays Rack Mount Instructions Part Number: R724M Rev. A01 Copyright 2010 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks
More informationIn-Ground Basketball System Owners Manual
In-Ground Basketball System Owners Manual Customer Service Center N53 W4700 South Corporate Circle Sussex, WI 53089 U.S.A. Write Model Number From Box Here: WARNING! 3 Capable Adults REQUIRED TOOLS AND
More informationBUILD A TABLETOP LOOM
BUILD A TABLETOP LOOM From 1" x 2" stock (actual 3/4" x 1"1/2) cut: 4 pieces 15" long 4 pieces 5"1/2 long Use the above to make 2 frames for the front and back of the loom. From 1" x 4" stock (actual 3/4"
More informationAssembly and Usage Instructions
Assembly and Usage Instructions A Product 5885 West Van Horn Tavern Road Columbia, MO 65203 www.caldwellshooting.com Instruction #1001667 Limited Warranty Every Caldwell product is warrantied to be free
More informationUninterruptible Power Supply. 500 kva - 750 kva
9 315 Uninterruptible Power Supply 500 kva - 750 kva T1 and T3 Installation Addendum 164201244-001 Rev. A ------------------------------------------------------------------------ ------------------------------------------------------------------------
More informationLG G5 Chassis Brace Gen 5 Camaro THE MOST POWERFUL HEADERS ON THE PLANET Brought to you by LG Motorsports 972-429-1963
LG G5 Chassis Brace Gen 5 Camaro THE MOST POWERFUL HEADERS ON THE PLANET Brought to you by LG Motorsports 972-429-1963 Thank you for purchasing LG Motorsports products for your Gen 5 Camaro. Parts Inventory:
More informationEZ-48-3AB-125-35 Weather Station Mounting Tripod and Mast
EZ-48-3AB-125-35 Weather Station Mounting Tripod and Mast EZ-125-35M 35 Mast Extension (Optional) EZ-125-SK Stake Kit (Optional) EZ-46-3 Tar Pad Kit (Optional) EZ-GWA Guy Wire Kit (Optional) Ambient Weather
More informationYINGLI SOLAR PV MODULES Installation and User Manual
YINGLI SOLAR PV MODULES Installation and User Manual Revision Date December 24, 2011 Applicable for IEC certified products This manual applies to photovoltaic modules ( PV modules, also commonly known
More informationAndersen Electric Window Opener for Andersen Awning and Roof Windows
W A Electric Window Opener Electric Window Opener for Awning and Roof Windows Congratulations! You have just purchased one of the many fine products. For ease of installation and continued enjoyment of
More informationHow to Install UnderDeck The Original.
How to Install UnderDeck The Original. TOOLS: Chalk Line Caulk Gun Garden hose or water bucket Gloves Hammer or Screw Gun Power Mitre Saw with OSB Blade Pencil Pliers Safety Glasses Straight Edge / Carpenter
More informationGuideline for Fire Safety Elements of Solar Photovoltaic Systems July 17, 2008 Rev: 1/1/10
Guideline for Fire Safety Elements of Solar Photovoltaic Systems July 17, 2008 Rev: 1/1/10 This document was developed by the Orange County Fire Chiefs Association, Orange County Fire Marshal Committee.
More informationInstallation Guide of Sunrise Solartech PV Modules. Term 2013. Contents. Purpose of this guide. General. Safety precaution for installing a solar
Installation Guide of Sunrise Solartech PV Modules Term 2013 Contents Purpose of this guide General Safety precaution for installing a solar Photovoltaic system Product Identification Mechanical Installation
More informationInstallation Guide. Sloped Roof Mounting System (60 Cell Modules) Version 2.5
Installation Guide Sloped Roof Mounting System (60 Cell Modules) Version 2.5 Sloped Roof Mounting System Install Guide (60 Cell Modules) No part of this publication may be reproduced, stored in a retrieval
More informationINSTALLATION INSTRUCTIONS. 6111 Air Spring Kit 2011+ Ford F250/F-350 Single Wheel 2WD 2011+ Ford F350 Dually 2WD IMPORTANT NOTES
INSTALLATION INSTRUCTIONS 6111 Air Spring Kit 2011+ Ford F250/F-350 Single Wheel 2WD 2011+ Ford F350 Dually 2WD Thank you for purchasing a quality Hellwig Product. PLEASE READ THIS INSTRUCTION SHEET COMPLETELY
More informationYINGLI SOLAR PV MODULES Installation and User Manual
YINGLI SOLAR PV MODULES Installation and User Manual Revision Date March 1, 2012 Applicable for products in the United States and Canada. This manual applies to photovoltaic modules ( PV modules, also
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More informationGEH6290. Mechanism Circuit Breaker. Handle Operating Mechanism Cat. No. Type NEMA 1, 3R, 12, 13 NEMA 4/4X Cat. No. Cat. No. Series Instruction
GEH6290 g Cable Operator Mechanisms for E150, SE150, SF250, and SG600 Spectra RMS Circuit Breakers Type SCH1/1X, SCH2/2X Flange-Mounted Handle Assemblies, Cable Series SC3L SC10L and Type SC0M1A, SCOM1EF,
More informationInstallation Instructions
READ BEFORE INSTALLING UNIT For Through-the-Wall Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
More informationTwo most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:
Two most common lock nut groups: 1. PREVAILING TORQUE a design feature of the lock nut produces friction between threads of mated components thereby increasing the force needed to tighten as well as loosen
More informationCeiling Mounted Folding Attic Ladders Installation Instructions
Ceiling Mounted Folding Attic Ladders Installation Instructions WARNING Before you start installing your new Louisville Ceiling Mounted Folding Attic Ladder, you must read and understand the following:
More informationES-A Series Photovoltaic Panels
Guide This Guide is valid in North America only (ETL listed; conforms to UL Standard 1703) ELECTRICAL EQUIPMENT CHECK WITH YOUR INSTALLER Evergreen Solar ES-A Series photovoltaic (PV, solar electric) panels
More informationSelect Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
More informationHow To Mount An Ecosa Series Solar Panel
(including PanelClaw ) This Guide is valid in North America only (ETL listed; conforms to UL Standard 1703) PanelClaw is a registered trademark of PanelClaw, Inc. SM-0050revA ELECTRICAL EQUIPMENT CHECK
More informationHow To Make A Thomas Bunk Bed
pottery barn kids THOMAS BUNK BED WARNING: Failure to follow these warnings and assembly instructions could result in serious injury or death. Read all instructions before assembling bunk bed. KEEP INSTRUCTIONS
More informationWARNING! DO NOT ATTEMPT TO INSTALL THIS KIT IN A POWERED CONVEYOR.
Model: Document Number: 64058111 Kit Number: 64058112 Revision: 02 Description: Release Date: 04/08 Introduction This kit allows a PS90 scale to be integrated into a standard gravity conveyor. The kit
More informationSERVICE MANUAL. Corpus 3G. Seat system for electric wheelchair
SERVICE MANUAL US Corpus 3G Seat system for electric wheelchair How to contact Permobil Head Office of the Permobil group Produced and published by Permobil AB, Sweden Version 4, 2014-07 Item No.: 205260-US-0
More informationRZ Guardrail System Installation Manual
TM RZ Guardrail System Installation Manual RZ Guardrail System Compliance is based on OSHA standards: (Standards - 29 CFR) 1910.23 (e) and (Standards - 29 CFR) 1926.502 (b) Failure to read, understand
More informationSolar Water Heating and Solar Electric Generators Installed on One or Two Family Dwellings
Solar Water Heating and Solar Electric Generators Installed on Category: Residential Construction Revised: [Paul L. Scarlett], Director Responsible Bureau Section: Development Services Center 1900 SW Fourth
More informationAll-Season Sunroom Sliding Glass Door Installation Instructions
ASRESGD-08 All-Season Sunroom Sliding Glass Door Installation Instructions Panel Frame Door Frame Left Side Foam Insulator IE241 H Bar Assembly Door Frame Top Track Panel Frame Door Frame Right Side Stationary
More informationSnapNrack TM SERIES 100 Roof Mount InstallaTIon manual SERIES 100 ROOF MOUNT
SnapNrack TM SERIES 100 Roof Mount InstallaTIon manual SERIES 100 ROOF MOUNT CODE COMPLIANT INSTALLATION MANUAL 2012 i Table of Contents 1. INTRODUCTION...3 1.1 OVERVIEW OF THE SNAPNRACK SYSTEM...3 1.2
More informationREPLACEMENT INSTRUCTIONS FOR AWNING
REPLACEMENT INSTRUCTIONS FOR AWNING Fabric Roller Tube Torsion Assembly For Models 8500 & 9000 Tools Required: Vise Grips Socket Wrench Set 3/16" rill Bit 1/8" Pop Rivets End Cap Guide Screwdriver Electric
More informationJames M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
More informationPost Mount Light Installation*
Post Mount Light Installation* *For the general installation of most Post Mount Spotlights, many vehicles may need slight modifications to these instructions. You will need the following tools: High torque
More information2.4M SERIES 1241 ANTENNA
4096-859 Revision A August 7, 2012 2.4M SERIES 1241 ANTENNA GENERAL DYNAMICS SATCOM Technologies 1500 Prodelin Drive Newton NC 28658USA Phone 828-464-4141 www.gdsatcom.com Prodelin Corporation Page 1 8/17/2012
More informationOwner s Manual Gantry Cranes
Owner s Manual Gantry Cranes Fixed Height Gantry Crane MODEL NUMBER: SERIAL NUMBER: CAPACITY IN TONS: Telescoping Gantry Crane Bushman AvonTec 262-790-4200, 800338-7810, Fax 262-790-4200 www.bushmanavontec.com
More informationIKG Bar Grating: Anchoring
IKG Bar Grating: Anchoring All bar grating must be tightly fastened in place. Welding of the grating panels to the supporting members provides a superior, permanent installation. Although, for gratings
More informationPANELIZED HOME INSTALLATION GUIDELINE
PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.
More informationModel # 940P-V6. Page 1 of 11
Model # 940P-V6 Page 1 of 11 Page 2 of 11 WARRANTY & TERMS WARRANTY: 5 Year Limited Warranty on Thermoplastic coated elements. Ultra Play guarantees all items for one full year to be free of defects in
More informationStep 1. Item 6. Item 1
Voltage Regulators QD3/T350 Motor Replacement Kit Kit Number 57A63675100B Service Information S225-50-35 Contents General..................................... 1 Parts Supplied...............................
More informationTable of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide
Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3
More informationR O A D M A S T E R, I N C.
R O A D M A S T E R, I N C. 6 28 1 2 "ā 1 2 " 4 8 ITEM QTY NAME PART # 1...4...1/2 x 1 1/4 BOLTS... 350094-00 2...4...1/2 LOCK WASHER... 350309-00 3...4...1/2 HEX NUT... 350258-00 4...2...SPACER PLATE...
More informationStructural Holding System
Structural Holding System Users Manual November 2013 by Vehicle Service Group. All rights reserved. CO8812.1 502071 Rev. - 11/21/2013 CHIEF'S LIMITED ONE-YEAR WARRANTY & LIABILITY Chief Automotive Technologies
More informationCabinets 101: Configuring A Network Or Server Cabinet
Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What
More informationWhalen Furniture Mfg. Inc. Factory No. 43-11696 Page # 1
ADULT ASSEMBLY REQUIRED DUE TO THE PRESENCE OF SMALL PARTS, SHARP POINTS, SHARP EDGES If you have any questions regarding assembly or if you are missing parts, do not return this item to Sam s Wholesale
More information10 ft x 20 ft / 3 m x 6 m STEEL FRAME CAR CANOPY
10 ft x 20 ft / 3 m x 6 m STEEL FRAME CAR CANOPY Instruction Manual ITM./ART.496840 VIEW ASSEMBLY VIDEO AND INSTRUCTION MANUAL AT www.zhengteusa.com Before assembly, read these instructions carefully.
More informationC O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S
C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family
More informationINSTALLATION INSTRUCTIONS for Bifold Doors (JII103)
Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for premium composite, hollow and solid core molded Bifold Doors. Bifolds are designed for fast
More informationSPIRAL STAIR KIT INSTALLATION MANUAL
SPIRAL STAIR KIT INSTALLATION MANUAL Effective January 1, 2014 If you have any questions, please call the location that your Stair Kit was purchased from: Broomall, Pennsylvania 1-800-52-7427 Ontario,
More informationTracRac G2. Overhead Rack Installation Instructions. TracRac Inc. 994 Jefferson St. FallRiver MA 02721 www.tracrac.com 800-501-1587 IN-42000_B
IN-42000_B TracRac G2 Overhead Rack Installation Instructions TracRac Inc. 994 Jefferson St. FallRiver MA 02721 www.tracrac.com 800-501-1587 Thank you for your purchase of a TracRac G2 Sliding Cargo Manaagement
More informationStrut Spring Compressor
Strut Spring Compressor Item 43753 Read this material before using this product. Failure to do so can result in serious injury. SAVE THIS MANUAL. When unpacking, make sure that the product is intact and
More information