A low friction and ultra low wear rate PEEK/PTFE composite
|
|
|
- Candice Smith
- 9 years ago
- Views:
Transcription
1 Wear 261 (2006) A low friction and ultra low wear rate PEEK/PTFE composite David L. Burris, W. Gregory Sawyer Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL 32611, United States Received 9 March 2005; received in revised form 28 October 2005; accepted 12 December 2005 Available online 2 February 2006 Abstract This paper presents a PEEK filled PTFE composite that exhibits low friction and ultra-low wear. It is hypothesized that a synergistic effect shuts down the dominant wear mechanism of each constituent. The friction coefficient and wear rate of this composite material on lapped stainless steel were evaluated for samples with PEEK wt.% of 0, 5, 10, 20, 30, 40, 50, 70 and 100 using a linear reciprocating tribometer. Tests were performed in filtered, standard laboratory conditions with a nominal contact pressure of 6.35 MPa, a speed of 50 mm/s and total sliding distances ranging from 0.5 km for the unfilled PTFE to 140 km for a 20 wt.% PEEK filled sample. The friction coefficients, averaged over an entire test, ranged from µ = for a 50 wt.% composite to µ = for unfilled PEEK. Wear rates ranged from K = mm 3 /(Nm) for a 20 wt.% PEEK sample to K = mm 3 /(Nm) for unfilled PTFE. Scanning electron microscopy revealed a unique interfacial connection between the PTFE and PEEK that is likely responsible for the ultra low wear rates observed in these experiments Published by Elsevier B.V. Keywords: Solid lubricants; Nanocomposites; Polymer; Composites; Low friction; Low wear; Friction; Wear; Space; Bearing 1. Introduction Solid lubrication is an attractive option for the design engineer for a variety of reasons, including, simplicity, cleanliness, low expense, quiet operation, low maintenance, low outgassing and high temperature capability. Often, a design necessitates a low wear solid lubricant either for long life or to maintain proper kinematics. Very few materials, however, exhibit low friction and low wear, so the designer is forced to add cost and complexity to accommodate one or the other. There are significant efforts dedicated to the research and development of such solid lubricants; polymers and polymer composites are commonly used as solid lubricants (the state-of-the-art was reviewed by Zhang [1] and Friedrich [2]). Though not exhaustive, Fig. 1 contains plots of wear rate versus filler wt.% for many different polymer composites. The work reported here explores a particular type of polymer composite that has two constituents: polyetheretherketone (PEEK) and polytetrafluoroethylene (PTFE). In its neat form, PEEK has high wear resistance, strength, operational temperature, friction coefficient (µ 0.4 in dry sliding), and low thermal conductivity. PTFE is a widely used and Corresponding author. Tel.: ; fax: address: [email protected] (W.G. Sawyer). well-known solid lubricant that suffers from a high wear rate. Both PEEK and PTFE are very common matrix materials for solid lubricant composites, and there are a number of publications that include composites of PTFE and PEEK for tribological applications [3 9]. In the main, fillers are added to PEEK to reduce the friction coefficient and they are added to PTFE to increase the wear resistance. PEEK is a high performance injection moldable polymer that finds applications in many components that require high strength and operating temperature. Like PTFE, PEEK is also resistant to many aggressive solvents and has a very low vapor pressure, making it suitable for vacuum applications. There are a number of commercially available PTFE-filled PEEK components marketed under a variety of trade names. Recently, Bijwe et al. [9] systematically studied the influence of PTFE inclusion in PEEK to determine an optimum loading of PTFE. The PTFE and PEEK were blended using a twin-screw melt mixer. In order to maintain the ability to injection mold parts, the PTFE volume fractions are limited; in this case between 0 and 30 wt.%. The results showed a monotonic decrease in friction coefficient, wear rate, and most mechanical properties with increasing PTFE content. Another approach to forming composites of PEEK and PTFE is to follow the processing techniques of molding PTFE, which typically uses cold pressing and consolidation followed by sintering. Briscoe et al. [8] made samples of PEEK-filled PTFE /$ see front matter 2006 Published by Elsevier B.V. doi: /j.wear
2 D.L. Burris, W.G. Sawyer / Wear 261 (2006) Fig. 1. Results from wear tests for representative polymer matrix composites found in the literature. Wear rate is plotted vs. filler wt.%: PTFE FEP [16], PA6 HDPE [17], PA11 GF [18], PEEK Si 3 N 4 [19], PTFE ZnO [20], PTFE CNT [21], PTFE Al 2 O 3 [21], PTFE B 2 O 3 [22], Epoxy B 2 O 3 [22], and PEEK PTFE [2]. from 0 to 100 wt.% PEEK; the powders were blended using a blade mixer, compressed, and sintered. The results showed a monotonic increase in wear rate with PTFE content and monotonic decrease in friction coefficient. The differences between the study by Bijwe et al. [9] and Briscoe et al. [8] are likely related to materials, processing, and microstructure. In this study, we will process the composites following procedures that were developed for creating nanocomposites of PTFE and alumina. This process used jet-milling to break apart agglomerations, and the compression molding process involved sintering under hydrostatic pressure [10]. 2. Materials and composite processing The PTFE and PEEK are acquired in powder form. The powders are mechanically ground and sifted prior to blending and jet-milling. The PTFE powder used in this study is 7C Teflon powder from Dupont with agglomerated sizes between 100 and 1000 m. The PEEK powder used in this study is a custom ground Victrex 450PF with a smaller agglomerated size prior to milling. Scanning electron images of the constituent powders are shown in Fig. 2; on average, the PTFE particles are 25 min Fig. 3. An illustration of the targeted composite structure, where the major phase (PTFE) exists as neat regions interconnected via PTFE fibrils. The PEEKenriched material encasing the neat regions of PTFE may also be interconnected. The PTFE running films thought to be responsible for lubrication are shown originating from neat PTFE as noted and illustrated. diameter and the PEEK particles are 5 m in diameter. Composite samples of 0, 5, 10, 20, 30, 40, 50, and 70 wt.% PEEK were created following the same approach as reported in [10]. The targeted structure is shown schematically in Fig. 3, and consists of PEEK enriched reinforcing material encasing regions of unfilled PTFE. Thin running films of PTFE are thought to develop during sliding to provide lubrication. The milled powder ensembles are compacted with 15 MPa of pressure for 10 s. The pressure is lowered to 2 MPa and a temperature ramp of 120 C/h is implemented until the hold temperature of 360 C is reached. After 3 h at temperature, the sample is cooled at 120 C/h. The mold produces 19 mm diameter 25 mm long cylinders. Samples measuring 6.3 mm 6.3 mm 12.7 mm long are machined out of the interior of the compression molded cylinders using a numerically controlled milling machine. The samples are weighed on a precision analytical balance with a range of 220 g and a resolution of 10 g; the bulk densities of the samples are calculated using these measurements. The counterfaces are plates of AISI 304 stainless steel measuring 38 mm 25.4 mm 3.4 mm. This material has a measured Rockwell B hardness of 87.3 kg/mm 2. The surfaces are prepared using a standard lapping finish and examined with a Fig. 2. Scanning electron micrographs of the constituent powders before jet-milling. Both materials are agglomerated prior to blending, and the blend material is compression molded to make this PTFE PEEK composite. The PTFE and PEEK agglomerations have characteristic sizes ranging from 100 to 1000 and m, respectively. The disbanded PTFE and PEEK particles have characteristic sizes ranging from 5 to 25 and 2 10 m, respectively.
3 412 D.L. Burris, W.G. Sawyer / Wear 261 (2006) scanning white light interferometer. Areas of 23 m 300 m were measured for five regions of five counterfaces. The average and standard deviation of the root-mean-squared roughness calculations are R q = 161 nm and σ = 35 nm, respectively. 3. Experimental procedure A laboratory designed linear reciprocating tribometer was used to test the wear and friction of the samples; this testing apparatus and the uncertainties associated with the experimental measurements are described in detail in Refs. [11 13]. Although open to the air, the entire apparatus is located inside a soft-walled cleanroom with conditioned laboratory air of relative humidity between 25 and 50%. The composite samples are mounted directly to a six-channel load cell and the counterface is mounted to a linear reciprocating stage. Prior to testing, the counterfaces are washed in soap and water, cleaned with acetone, sonicated for 15 min in methanol, and dried with a laboratory wipe. After dry machining, the composite samples are wiped down with methanol. A normal force of 250 N is applied via a pneumatic cylinder/linear thruster assembly, and results in a nominal contact pressure of 6.25 MPa over the 40 mm 2 pin area. The load is continuously monitored and computer controlled using an electropneumatic valve. The reciprocating length is 25.4 mm with an average sliding speed of 50.8 mm/s. Instantaneous data is collected for normal load, friction force, table position and pin position at 1000 Hz over one cycle at specified intervals. The instantaneous data are averaged over two cycles and saved at specified intervals that depend on the length of the test. Interrupted mass measurements are used to quantify wear rather than dimensional measurements of pin height because of sample creep and thermal expansion. These wear measurements are made periodically during each test. Steady state wear rates and uncertainties are reported in this study following techniques discussed in [13]. The uncertainty intervals on wear rate data represent the experimental uncertainty in the measurement while the confidence intervals on friction coefficient data represent the standard deviation of the friction coefficient for the entire test [14]. The volume loss of a preliminary 20 wt.% sample had a corresponding wear depth of 6 m across the sliding surface after 100 km at 6.35 MPa of contact pressure. It is unclear what the statistical fluctuations in composition are over such a small volume of the composite (i.e. to what degree can the bulk composition be used to estimate the very near surface composition of these samples that experience ultra low wear). In order to estimate the magnitudes of the variation in composition as a function of volume, a diamond saw was used to cut several samples into parallel slices of varying thickness (the smallest sample made using this technique was approximately 10 mm 3 ). Here a batch is defined as a group of slices of equal volume cut from a single sample. The ratio of the standard deviation of the measured densities (σ ρ ) to the density of the composite (ρ c ) followed a power law relationship with the volume of the slice ( ) measured in cubic millimeters; this is given in Eq. (1). The equation for wt.% based on density measurements is given in Eq. (2). (1) ( ) ρ PEEK ρptfe wt.% PEEK = (2) ρ PTFE ρ PEEK ρ c The confidence intervals on filler wt.% are calculated using the measured mass change in the sample after testing and the initial density of the composite, and represent one standard deviation of the expected filler wt.% of these worn surface regions. Although the most wear resistant composites are run the longest to maximize wear volume, they often have the greatest uncertainty in their near surface composition with many samples losing less than a cubic millimeter of material. 4. Results The friction coefficients of the composites are shown in Fig. 4 as functions of the sliding distance and position along the wear track. The composites all had little fluctuations in friction coefficient along the wear track. The smooth shape along the wear track is characteristic to PTFE systems. Unfilled PTFE and PEEK have average friction coefficients of µ = and µ = 0.363, respectively. The 20 wt.% composite has steady frictional behavior with an average friction coefficient of µ = The composites containing less than 20 wt.% PEEK had initial friction coefficients equal to unfilled PTFE that gradually approached the friction coefficient of the 20 wt.% composite; the 70 wt.% composite behaved in a similar fashion. The composites with more PEEK than 20 wt.% (except the 70 wt.% composite) Fig. 4. Coefficients of friction vs. sliding distance for a number of composite samples varying from unfilled PTFE to unfilled PEEK. Filler wt.% reflects the prepared composition of the powder blends. Coefficient of friction vs. track position is also plotted for the composites after sliding for approximately 40 km. The 5 and 10 wt.% data was taken near the ends of the tests. Sample surfaces are 6.35 mm 6.35 mm under 250 N of normal load and the reciprocation length is 25.4 mm at a speed of 50.8 mm/s.
4 D.L. Burris, W.G. Sawyer / Wear 261 (2006) Fig. 5. Volume loss vs. sliding distance for a number of composite samples varying from unfilled PTFE to unfilled PEEK. A log log plot is inset for easier visualization of the many orders of magnitude variation in wear rates. Filler wt.% reflects the prepared composition of the powder blends. Volume loss is calculated from mass measurements and the calculated density. The uncertainty intervals on volume loss are noted and calculated from [13]. The sample surfaces are 6.35 mm 6.35 mm under 250 N of normal load and the reciprocation length is 25.4 mm at a speed of 50.8 mm/s. Fig. 6. Friction coefficient for the composites plotted as a function of PEEK filler wt.% as calculated using the measured sample density. The vertical confidence intervals represent the standard deviation of the friction coefficient over the entire test, while the horizontal confidence intervals are calculated following Eqs. (1) and (2). Sample surfaces are 6.35 mm 6.35 mm under 250 N of normal load and reciprocation length is 25.4 mm at a speed of 50.8 mm/s (the total sliding distance varied). had low initial friction coefficients that increased to a steady state friction coefficient equal to that of the 20 wt.% composite. In Fig. 5 the volume loss of each sample is plotted versus the sliding distance. A log log plot has been included for clearer visualization of the data. The unfilled PTFE and PEEK had steady state wear rates of K = and K = mm 3 /(Nm), respectively. The composite samples were all more wear resistant than the unfilled PEEK sample. The samples with less than 20 wt.% PEEK have initial transient regions of high wear followed by a gradual decrease in wear that approaches steady state. The 20 wt.% sample performed best, having a small transient period that was followed by a steady state during which no change in mass was detected for the last one million sliding cycles (the scale has a resolution of 10 g). The samples having more than 20 wt.% PEEK wore nearly linearly from the onset of sliding; the wear rates generally increase with increasing PEEK content. Fig. 6 shows the time-averaged friction coefficients for all of the tested samples plotted versus filler wt.% as calculated from density measurements. The lowest friction coefficient is µ = with 50 wt.% PEEK. The friction coefficients tend toward that of unfilled PTFE as the wt.% of PEEK goes below 50 wt.%. Above 50 wt.% PEEK, the friction coefficient increases, but remains less than that of unfilled PTFE at 70 filler wt.%. Fig. 7 shows the steady state wear rate plotted versus filler wt.% as calculated by density measurements. At PEEK concentrations greater than 30 wt.%, the wear rates increase monotonically with PEEK content. At PEEK wt.% less than 30, the wear Fig. 7. Wear rates calculated from interrupted mass measurements for the composites plotted as a function of PEEK filler wt.% as calculated using the measured sample density. The uncertainty intervals on wear rate are calculated according to [13], while the horizontal confidence intervals are calculated following Eqs. (1) and (2). Sample surfaces are 6.35 mm 6.35 mm under 250 N of normal load and reciprocation length is 25.4 mm at a speed of 50.8 mm/s (the total sliding distance varied). rates approach the wear rate of unfilled PTFE as filler content is reduced. 5. Discussion Nearly all of the composites had lower average friction coefficients than unfilled PTFE, which is in contrast to what might be expected from a linear rule of mixtures approach. The mechanism for this reduction in friction coefficient is believed to originate from thin running films of PTFE that are drawn out over the PEEK enriched regions. These running films then slide against a transfer film that develops on the surface of the stainless steel counterface. The friction coefficient of the composite material was lowest at approximately 50 wt.% PEEK. As the PEEK content is
5 414 D.L. Burris, W.G. Sawyer / Wear 261 (2006) increased from unfilled PTFE, friction is lowered because the shearing of low strength running films is over an increasingly stiff material with less real area in contact. At some filler wt.% the spacing of the PTFE reservoirs and size of PEEK reinforced regions become such that the running films cannot completely lubricate the PEEK. Adhesion and fracture can liberate pieces of PEEK, which can abrade the composite, further increasing the frictional forces. Like friction, wear resistance also fails to follow any rule of mixture explanation. The best performing composite sample (20 wt.% prepared, 32 wt.% PEEK calculated with density) is 260,000 times more wear resistant than unfilled PTFE and 900 times more wear resistant than unfilled PEEK. It wore a total of 0.24 mm 3 under 250 N of load after the first 50 km of dry sliding and then reached a steady state where no change in mass was detected for the last 50 km. This corresponds to the dissipation of 1.5 MJ of frictional energy over a 40 mm 2 surface without detectable (to 10 g resolution) material removal. The wear resistance mechanism is unclear; it was hypothesized that a co-continuous network structure of PTFE and PEEK would prevent delamination in PTFE and the reduced friction coefficient would reduce the fracture induced wear of PEEK. One of the unique aspects of this composite is that the PEEK particles are small compared to the PTFE particles, potentially facilitating a network structure similar to that described in the nanoparticle filled research with PTFE and alumina [10,15]. At filler loadings less than 32 wt.% the transient region of wear is longer and more pronounced as the filler content approaches zero. There are a number of possible explanations for this behavior: (1) there is insufficient PEEK to create a network, (2) the increased area of PTFE and increased spacing of PEEK prevents the interruption of damage to the PTFE, and (3) the increased real area of contact causes more PTFE to be engaged at the interface. The low wt.% samples wear rates slowly approached those of the more wear resistant samples; this suggests that some surface accumulation of PEEK had occurred. To investigate this effect further, five identically prepared 15 wt.% PEEK composite samples were tested under the standard conditions for one of five numbers of sliding cycles: ,1 10 5,5 10 5, and The instantaneous wear rate and friction coefficient are plotted as functions of reciprocation cycles in Fig. 8 for this series of tests. The wear Fig. 8. Instantaneous wear rate and friction coefficient plotted as functions of reciprocation cycles. The uncertainty intervals on wear rate are calculated according to [13] for the last two mass measurements in each test, and the confidence intervals on friction coefficient represent the standard deviation of friction measurements made throughout the test as described in [14]. Sample surfaces are 6.35 mm square under 250 N of normal load and reciprocation length is 25.4 mm at a speed of 50.8 mm/s. rate approaches those of the optimum composition as the number of reciprocation cycles builds. At PEEK concentrations above 32 wt.% the wear rate increased monotonically with 30 PEEK content. Qualitatively, optical microscopy of these samples revealed a smooth surface with increasing sizes and amounts of fractured regions in the composite with increasing wear rates and wt.% above 32 filler wt.%. It appears that at high PEEK concentrations, the increased number of large regions of PEEK leads to a fatigue/fracture wear mechanism. This behavior is also consistent with the idea that as PEEK content increases, the size of the PEEK domains and the spacing of the PTFE reservoirs increase, and may prohibit the full lubrication of the PEEK. As these regions of PEEK are fractured, third body abrasion can lead to damage of the transfer films and plowing of the composite. The use of small PEEK particles and fibrillation of PTFE during jet-milling allows a specific microstructure to form as the PEEK particles coalesce around fibrils during melt. Fig. 9 shows digital enhancement of an optical micrograph of a 20 wt.% PEEK composite sample after 20 h at the maximum processing Fig. 9. Optical micrograph illustrating the microstructure of a 20 wt.% PEEK filled PTFE composite after processing at 360 C for 30 h. The sample was sanded flat and polished with 2000 grit silicon carbide wet abrasive paper prior to imaging. Left: original image with PEEK as the light colored phase; center: PEEK is highlighted in blue; right: The background PTFE is removed for clarity. There is a clearly networked region of PEEK containing regions of PTFE in the center of the image. For interpretation of the references to colour in this figure legend, the reader is referred to the web version of the article.
6 D.L. Burris, W.G. Sawyer / Wear 261 (2006) Fig. 10. Friction coefficient and wear volume at the completion of 1.25 million cycles (the total sliding distance was 63.5 km and the applied load was 250 N) plotted vs. the maximum temperature hold time (h) during compression molding. Optical micrographs with computational identification of the visible PEEK microstructure (following Fig. 9) after sectioning are shown above the graph. There is a clear increase both the size and number density of visible PEEK domains (all composites have the same 20 wt.% of PEEK); the wear rate and friction coefficient appear independent of time at temperature. temperature of 360 C. The sample was sectioned with a diamond saw, wet abraded with 600 grit silicon carbide paper, and polished on a lapping wheel with 2000 grit silicon carbide paper. Continuous regions of PEEK can be seen spanning up to 1 mm in length. It is clear that many 5 m particles must have coalesced during melt to form such a complex microstructure. The effect of this time dependent coalescence on the tribological properties was studied by processing four identically prepared 20 wt.% powders with times at melt of 0.03, 0.3, 3 and 30 h. These samples were tested under the standard conditions for 1,250,000 cycles of sliding. Fig. 10 shows the worn volume and average friction coefficient plotted as functions of the time at melt during processing at the completion of 1,250,000 wear cycles. These results show little dependence of friction and wear to time at melt during processing. These samples were sectioned with a diamond saw, wet abraded with 600 grit silicon carbide paper, and polished on a lapping wheel with 2000 grit silicon carbide paper for optical microscopy observation of the microstructure. The results of these observations are shown in Fig. 10; the PEEK was computationally identified and highlighted in blue. Despite the lack of difference in tribological properties of these samples, optical microscopy did show some development of the microstructure with increasing time at temperature. As the time at process temperature increases, both the size and number density of the visible domains of PEEK increase. Several groups have published work with PTFE PEEK composites, all finding statistically significant tribological improvements over the neat materials. However, the Fig. 11. Results of uniaxial compression tests of neat PEEK and PTFE as controls, and a 30 wt.% (45 vol.%) PEEK/PTFE composite. The responses of equal strain and equal pressure 45 vol.% composites were calculated based on the measured neat material responses, and are plotted with the data for comparison. improvement in the wear resistance of this particular form of the composite indicates that there is some fundamental microstructural difference in these composites (as discussed previously modifications of the gross networked structure showed no effect on the tribological behavior). This difference was believed to be a unique microstructure that results from the combined effects of small particles of PEEK and the jet-mill processing, but characterization efforts for this PEEK and PTFE composite with various 2-D microscopy and etching techniques were unsuccessful. Fig. 12. Experimental schematic and resulting optical image of a notched fracture experiment for a 30 wt.% specimen under quasi-static extension at room temperature. The stress raiser does not induce a fracture response; instead, the material fibrillates in the direction of the stress and elongates an estimated % prior to breaking.
7 416 D.L. Burris, W.G. Sawyer / Wear 261 (2006) In an attempt to gain insight into the microstructure by other means, a series of mechanical tests were conducted. The first of these was a creep test performed on neat PTFE, neat PEEK and a 30 wt.% composite. Tests were performed at room temperature in a dry N 2 environment with a uniaxial compressive stress of 10 MPa. The displacement was measured as a function of time. Two limiting composite structures, shown schematically in Fig. 11, are used to confine the expected response of the composite. The first structure has a predominant orientation perpendicular to the load. Because each constituent in the composite supports the same load, this model is referred to as the equal pressure model, and the mechanical response follows a simple linear rule of mixtures. Many structural composites have reinforcing fibers aligned with the load for superior strength and stiffness. Because the elongation of filler and matrix are equal, the composite behaves more like the reinforcing phase, and will be referred to as the equal strain model. The results of this creep testing are shown in Fig. 11. It is clear that the mechanical response of the composite did not follow a linear rule of mixtures. The effective elastic modulus of the composite is approximately equal to that of unfilled PEEK with a creep rate that was approximately 5% greater than for the equal strain composite. One would not expect equal strain behavior in a composite without intentional orientation, unless a continuous network of PEEK was present, or the mechanical properties of the matrix were somehow changed by incorporation of the filler. Other interesting mechanical properties to study from a tribological perspective are fracture toughness and strain to failure. These properties may correlate with wear resistance because they determine the ability of a material to absorb energy without liberating material from the bulk. To interrogate these properties, quasi-static extension of a notched 30 wt.% specimen was performed and compared to unfilled PTFE and a commercially available reinforced PEEK composite that exhibited excellent wear resistance (k mm 3 /Nm). The samples were cut with a razor blade to create a large stress concentration, mounted on a linear stage under a microscope, and quasi-statically extended until fracture. A schematic of the test and an optical micrograph of the failed composite sample (the PEEK and PTFE controls are not shown for brevity) are shown in Fig. 12. The composite sample was extended out of the field of view of the microscope without fracture. A rough estimate of strain to failure can be obtained by using the length of the discolored envelope of strained material as the effective original length of an equivalent tensile specimen located at the border of failed material. Using this approach an approximate strain at failure of % is obtained. The high resistance to fracture of this sample is in stark contrast to the results of identical tests with the neat PTFE and PEEK composite samples. The PEEK composite is strong but fractures easily with the presence of a defect. The PTFE gives little resistance to the opening and blunting of the crack, and fractures after incurring a large (but much less than the composite) amount of deformation. The compression creep test illustrates the stiffness of the composite, while the fracture experiment depicts the resistance of the composites to material removal. The highly strained material from Fig. 12 was next investigated with energy dispersive spectroscopic fluorine dot mapping and scanning electron microscopy (SEM) with the goals of identifying the fibrillating phase and characterizing the expanded 3-D microstructure. The sample was removed from the extension fixture and carbon coated before SEM observation. Fig. 13 shows an area originally near the crack tip, in a portion of material that did not fail. The fluorine map shows that the fibrillating phase is PTFE, while the dark particle phase is PEEK. It is interesting to note that the majority of the PEEK particles in the composite are on the order of 100 m while the PEEK powder has an average particle size of about 5 m. This further suggests that coalescence of the PEEK is occurring during melt. Fig. 14 shows a sequence of images at increasing magnification at a region bordering the failed material on the fracture sample. The 3-D nature of this sample gives a unique perspective into the microstructure that was not available on the two dimensional surfaces obtained by standard sectioning techniques. These images reveal a microstructure that is not networked in the originally hypothesized sense; particles of PEEK appear to be imbedded within a PTFE matrix. As a discrete particle is examined under higher magnification, the nano-scale networking of the PEEK becomes evident. The PEEK particle has many holes and irregularities, and appears as though it Fig. 13. Energy dispersive spectroscopic fluorine dot mapping of the expanded specimen after extension and removal from the test fixture. From left to right: SEM image of the mapped area; the fluorine dot map overlaying the image; the fluorine dot map. The PTFE is clearly identifiable as the fibrillating phase.
8 D.L. Burris, W.G. Sawyer / Wear 261 (2006) Fig. 14. Scanning electron images of the 30 wt.% fracture sample. This sample was extended, removed from the test fixture and carbon coated. From left to right: low magnification image revealing an undamaged PEEK particle; increased magnification image of the particle showing highly fibrillated microscale PTFE encapsulating the particle; high magnification image showing a networked structure of nanoscale PTFE fibrils trapped within the coalesced PEEK particle. coalesced around a fibrillated PTFE structure during melt. Fibrils of PTFE are thickest away from the particle and become thinner as they approach the PEEK. In the highest magnification image, fibrils of PTFE with diameters of around 100 nm can be observed connecting the PEEK to the PTFE. The fibrils seem to enter the PEEK through the holes and irregularities as if trapped during the coalescence process. The large amount of energy used in jet-milling is thought to fibrillate the PTFE. Upon melt, the PTFE is much more viscous than the PEEK, giving more resistance to motion. The PEEK particles are forced to coalesce around the PTFE fibrils setting up the observed nanoscale networking of the PEEK and PTFE. This interfacial connection is significant since PTFE and PEEK have negligible interfacial shear strength; without mechanical interlocking of both phases, PEEK particles can simply fall out of the matrix. This is likely the source of the exceptional wear resistance observed in wear tests of this composite. 6. Conclusions 1. This composite material has a friction coefficient lower than unfilled PTFE and PEEK for every sample tested. The lowest average friction coefficient of µ = was obtained for three samples having a PEEK wt.% of 50. The friction coefficient of PTFE was found to be µ = The composite has a wear rate lower than unfilled PTFE and PEEK for every sample tested. The lowest wear rate of K = mm 3 /(Nm) was obtained for a 32 wt.% PEEK filled sample. This sample was 900 times as wear resistant as the unfilled PEEK and 260,000 times as wear resistant as the unfilled PTFE. 3. Samples having a PEEK content greater than 32 wt.% had no wear transients. The wear rates were observed to increase with increasing PEEK content approaching that of unfilled PEEK. 4. Both PEEK networking and nanoscale penetration of PTFE through PEEK particles were found in this composite system. Acknowledgements This material is based upon work supported under NSF Grant No. #CMS , GOALI: Collaborative Research: Tribology of Nanocomposites and AFOSR-MURI grant FA Any opinions, findings, and conclusions or recommendations expressed in this material are those of the authors and do not necessarily reflect the views of the National Science Foundation or the Air Force Office of Sponsored Research. Special thanks are in order to Mr. Gerald Bourne for his tireless effort in support of the microscopy related portions of this work. References [1] S. Zhang, State-of-the-art of polymer tribology, Tribol. Int. 31 (1998) [2] K. Friedrich, Z. Lu, A. Hager, Recent advances in polymer composites tribology, Wear 190 (1995) [3] Q. Wang, Q. Xue, W. Liu, J. Chen, The friction and wear characteristics of nanometer sic and polytetrafluoroethylene filled polyetheretherketone, Wear 243 (2000) [4] Z. Zhang, C. Breidt, L. Chang, K. Friedrich, Wear of peek composites related to their mechanical performances, Tribol. Int. 37 (2004) [5] B. Stuart, Tribological studies of poly(etheretherketone) blends, Tribol. Int. 31 (1998) [6] J. Flock, K. Friedrich, Q. Yuan, On the friction and wear behaviour of pan- and pitch-carbon fiber-reinforced peek composites, Wear 229 (1999) [7] J. Voort, S. Bahadur, The growth and bonding of transfer film and the role of CuS and PTFE in the tribological behavior of peek, Wear 181 (1995) [8] B. Briscoe, L. Yao, T. Stolarski, The friction and wear of poly(tetrafluoroethylene) poly(etheretherketone) composites an initial appraisal of the optimum composition, Wear 108 (1986) [9] J. Bijwe, S. Sen, A. Ghosh, Influence of PTFE content in PEEK PTFE blends on mechanical properties and tribo-performance in various wear modes, Wear 258 (10) (2005) [10] W.G. Sawyer, K.D. Freudenberg, P. Bhimaraj, L.S. Schadler, A study on the friction and wear behavior of PTFE filled with alumina nanoparticles, Wear 254 (2003) [11] T.L. Schmitz, J.E. Action, W.G. Sawyer, J.C. Ziegert, Dynamic friction coefficient measurements: device and uncertainty analysis, in: Proceed-
9 418 D.L. Burris, W.G. Sawyer / Wear 261 (2006) ings of the 18th American Society of Precision Engineers, Annual Meeting, Portland, OR, [12] T.L. Schmitz, J.E. Action, D.L. Burris, J.C. Ziegert, W.G. Sawyer, Measurement uncertainty in tribological wear rate testing, Transactions of the 2003 North American Manufacturing Research Institute of Society of Manufacturing Engineers, [13] T. Schmitz, J. Action, D. Burris, J. Ziegert, W. Sawyer, Wearrate uncertainty analysis, J. Tribol. Trans. ASME 126 (2004) [14] T. Schmitz, J. Action, J. Ziegert, W.G. Sawyer, The difficulty of measuring low friction: uncertainty analysis for friction coefficient measurements, J. Tribol. 127 (2005) [15] D. Burris, W.G. Sawyer, Tribological sensitivity of PTFE alumina nanocomposites to a range of traditional surface finishes, Tribol. Trans. 48 (2005) 1 7. [16] T.A. Blanchet, Y.L. Peng, Wear resistant irradiated FEP unirradiated PTFE composites, Wear 214 (1998) [17] M. Palabiyik, S. Bahadur, Mechanical and tribological properties of polyamide 6 and high density polyethylene polyblends with and without compatibilizer, Wear 246 (2000) [18] S. Bahadur, V. Polineni, Tribological studies of glass fabric-reinforced polyamide composites filled with CuO and PTFE, Wear 200 (1996) [19] Q.H. Wang, J.F. Xu, W.C. Shen, W.M. Liu, An investigation of the friction and wear properties of nanometer Si 3 N 4 filled peek, Wear 196 (1996) [20] F. Li, K.A. Hu, J.L. Li, B.Y. Zhao, The friction and wear characteristics of nanometer ZnO filled polytetrafluoroethylene, Wear 249 (2001) [21] W.X. Chen, F. Li, G. Han, J.B. Xia, L.Y. Wang, J.P. Tu, Z.D. Xu, Tribological behavior of carbon-nanotube-filled PTFE composites, Tribol. Lett. 15 (2003) [22] B.R. Burroughs, J.H. Kim, T.A. Blanchet, Boric acid self-lubrication of B 2 O 3 -filled polymer composites, Tribol. Trans. 42 (1999)
CHAPTER 6 WEAR TESTING MEASUREMENT
84 CHAPTER 6 WEAR TESTING MEASUREMENT Wear is a process of removal of material from one or both of two solid surfaces in solid state contact. As the wear is a surface removal phenomenon and occurs mostly
Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.
Lab 3 Tension Test Objectives Concepts Background Experimental Procedure Report Requirements Discussion Objectives Experimentally determine the yield strength, tensile strength, and modules of elasticity
Evaluating Surface Roughness of Si Following Selected Lapping and Polishing Processes
Applications Laboratory Report 86 Evaluating Surface Roughness of Si Following Selected Processes Purpose polishing of samples is a common application and required for a variety of manufacturing and research
STATIC COEFFICIENT OF FRICTION MEASUREMENT USING TRIBOMETER. Static COF 0.00 0.0 0.5 1.0 1.5 2.0. Time(min) Prepared by Duanjie Li, PhD
STATIC COEFFICIENT OF FRICTION MEASUREMENT USING TRIBOMETER 0.20 Static COF Coefficient of Friction 0.15 0.10 0.05 0.00 0.0 0.5 1.0 1.5 2.0 Time(min) Prepared by Duanjie Li, PhD 6 Morgan, Ste156, Irvine
Mechanical Properties of Metals Mechanical Properties refers to the behavior of material when external forces are applied
Mechanical Properties of Metals Mechanical Properties refers to the behavior of material when external forces are applied Stress and strain fracture or engineering point of view: allows to predict the
Lapping and Polishing Basics
Lapping and Polishing Basics Applications Laboratory Report 54 Lapping and Polishing 1.0: Introduction Lapping and polishing is a process by which material is precisely removed from a workpiece (or specimen)
WOOD WEAR TESTING USING TRIBOMETER
WOOD WEAR TESTING USING TRIBOMETER Prepared by Duanjie Li, PhD 6 Morgan, Ste156, Irvine CA 92618 P: 949.461.9292 F: 949.461.9232 nanovea.com Today's standard for tomorrow's materials. 2015 NANOVEA INTRO
PTFE Slide Bearings 04/10 149
04/10 149 1.0 GENERAL INFORMATION In a wide range of applications, PTFE Slide bearings are superior to conventional expansion plates, rollers and rocker arm type supports. They support petrochemical plant,
Design and Fabrication of a Wear Testing Machine
Leonardo Electronic Journal of Practices and Technologies ISSN 1583-1078 Issue 19, July-December 2011 p. 39-48 Design and Fabrication of a Wear Testing Machine Amal Ebrahim NASSAR * and Eman Ebrahim NASSAR
Solid shape molding is not desired in injection molding due to following reasons.
PLASTICS PART DESIGN and MOULDABILITY Injection molding is popular manufacturing method because of its high-speed production capability. Performance of plastics part is limited by its properties which
Strength of Concrete
Strength of Concrete In concrete design and quality control, strength is the property generally specified. This is because, compared to most other properties, testing strength is relatively easy. Furthermore,
PROCESSING, PERFORMANCE, AND CHARACTERIZATION OF CONTINUOUS FIBER CERAMIC COMPOSITES WITH NANOPARTICLES
PROCESSING, PERFORMANCE, AND CHARACTERIZATION OF CONTINUOUS FIBER CERAMIC COMPOSITES WITH NANOPARTICLES David Narahara Department of Mechanical Engineering University of Hawai i at Mānoa Honolulu, HI 96822
THE WEAR OF INJECTION MOULD FUNCTIONAL PARTS IN CONTACT WITH POLYMER COMPOSITES
26 THE WEAR OF INJECTION MOULD FUNCTIONAL PARTS IN CONTACT WITH POLYMER COMPOSITES Janette Brezinová, Anna Guzanová Received 27 th January 2009; accepted in revised form 28 th February 2009 Abstract The
Figure 2.31. CPT Equipment
Soil tests (1) In-situ test In order to sound the strength of the soils in Las Colinas Mountain, portable cone penetration tests (Japan Geotechnical Society, 1995) were performed at three points C1-C3
Friction and wear properties of polyamides filled with
Friction and wear properties of polyamides filled with 1 Vanessa RODRIGUEZ, 1 Jacob SUKUMARAN, 1 Patrick DE BAETS, 1 Wouter OST, 1 Yeczain PEREZ DELGADO, 2 Mátyás ANDÓ 1 Department of Mechanical Construction
Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013
Scotch-Weld TM Product Data Sheet Acrylic Adhesives Date: Supersedes: August 2013 Product Description 3M TM Scotch-Weld Acrylic Adhesives are high performance, twopart acrylic adhesives that offer good
3. Test Methods for Evaluation of ESCR of Plastics
3. Test Methods for Evaluation of ESCR of Plastics A common laboratory request for ESC-prone polymers is to check ESCR performance for quality control, competitive product evaluations, and research and
Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope
Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope Rakesh Sidharthan 1 Gnanavel B K 2 Assistant professor Mechanical, Department Professor, Mechanical Department, Gojan engineering college,
Silicone Rubber Thermal Interface Materials: Applications and Performance Considerations
Silicone Rubber Thermal Interface Materials: Applications and Performance Considerations David C. Timpe Jr. Arlon Silicone Technologies Division 1100 Governor Lea Road, Bear, DE 19701 P: 800-635-9333 F:
CHARACTERIZATION OF POLYMERS BY TMA. W.J. Sichina, National Marketing Manager
PERKIN ELMER Polymers technical note CHARACTERIZATION OF POLYMERS BY W.J. Sichina, National Marketing Manager Thermomechanical analysis () is one of the important characterization techniques in the field
Phenomenological aspects of a modified fragmentation of the ground material
Phenomenological aspects of a modified fragmentation of the ground material Lucjan Dabrowski, Mieczyslaw Marciniak Warsaw University of Technology, Warsaw, Poland Summary: The main point of this paper
TIE-31: Mechanical and thermal properties of optical glass
PAGE 1/10 1 Density The density of optical glass varies from 239 for N-BK10 to 603 for SF66 In most cases glasses with higher densities also have higher refractive indices (eg SF type glasses) The density
THERMAL CONDUCTIVITY AND THERMAL EXPANSION COEFFICIENT OF GFRP COMPOSITE LAMINATES WITH FILLERS
THERMAL CONDUCTIVITY AND THERMAL EXPANSION COEFFICIENT OF GFRP COMPOSITE LAMINATES WITH FILLERS K. Devendra $ and T. Rangaswamy & $ Asst. Professor, Dept. of Mech. Engineering, SKSVMACET, Laxmeshwar, KA,
CARBON/DYNEEMA INTRALAMINAR HYBRIDS: NEW STRATEGY TO INCREASE IMPACT RESISTANCE OR DECREASE MASS OF CARBON FIBER COMPOSITES
26 TH INTERNATIONAL CONGRESS OF THE AERONAUTICAL SCIENCES CARBON/DYNEEMA INTRALAMINAR HYBRIDS: NEW STRATEGY TO INCREASE IMPACT RESISTANCE OR DECREASE MASS OF CARBON FIBER COMPOSITES J. G. H. Bouwmeester*,
Wear Resistant Thermoplastic Compounds
STRUCTURAL ELASTOMERS WEAR COLOR CONDUCTIVE FLAME RETARDANT FILM/SHEET Wear Resistant Thermoplastic Compounds Dr. Joel Bell Product Development Engineer RTP Company Agenda RTP Company Introduction Definitions
STRAIN-LIFE (e -N) APPROACH
CYCLIC DEFORMATION & STRAIN-LIFE (e -N) APPROACH MONOTONIC TENSION TEST AND STRESS-STRAIN BEHAVIOR STRAIN-CONTROLLED TEST METHODS CYCLIC DEFORMATION AND STRESS-STRAIN BEHAVIOR STRAIN-BASED APPROACH TO
INTRODUCTION TO SOIL MODULI. Jean-Louis BRIAUD 1
INTRODUCTION TO SOIL MODULI By Jean-Louis BRIAUD 1 The modulus of a soil is one of the most difficult soil parameters to estimate because it depends on so many factors. Therefore when one says for example:
Fundamentals of Friction and Wear of Automobile Brake Materials
Fundamentals of Friction and Wear of Automobile Brake Materials Shyam Bahadur, PhD., Fellow ASME, Fellow ASTM University Professor and Professor of Mechanical Engineering, Iowa State University, Ames,
Part and tooling design. Eastman Tritan copolyester
Part and tooling design Eastman Tritan copolyester Part and tooling design Process Part design Tooling design High cavitation considerations Process Process Project development flow chart Concept OEM generates
Nanotribology of Hard Thin Film Coatings: A Case Study Using the G200 Nanoindenter
Nanotribology of Hard Thin Film Coatings: A Case Study Using the G200 Nanoindenter Application Note Introduction Thin film coatings are extensively used in various applications, such as microelectronics,
POWDER PROPERTIES LABORATORY
Ground Rules POWDER PROPERTIES LABORATORY You will work as a team of no more than 6 students. At the end of this laboratory session each team will turn in a single report. The report will be reviewed,
LABORATORY EXPERIMENTS TESTING OF MATERIALS
LABORATORY EXPERIMENTS TESTING OF MATERIALS 1. TENSION TEST: INTRODUCTION & THEORY The tension test is the most commonly used method to evaluate the mechanical properties of metals. Its main objective
TWISTING OF FIBRES IN YARNS FOR NATURAL FIBRE COMPOSITES
18 TH INTERNATIONAL CONFERENCE ON COMPOSITE MATERIALS TWISTING OF FIBRES IN YARNS FOR NATURAL FIBRE COMPOSITES M. Rask 1 *, B. Madsen 1 1 Materials Research Division, Risø National Laboratory for Sustainable
Hardened Concrete. Lecture No. 14
Hardened Concrete Lecture No. 14 Strength of Concrete Strength of concrete is commonly considered its most valuable property, although in many practical cases, other characteristics, such as durability
Chapter Outline. Mechanical Properties of Metals How do metals respond to external loads?
Mechanical Properties of Metals How do metals respond to external loads? Stress and Strain Tension Compression Shear Torsion Elastic deformation Plastic Deformation Yield Strength Tensile Strength Ductility
, Yong-Min Kwon 1 ) , Ho-Young Son 1 ) , Jeong-Tak Moon 2 ) Byung-Wook Jeong 2 ) , Kyung-In Kang 2 )
Effect of Sb Addition in Sn-Ag-Cu Solder Balls on the Drop Test Reliability of BGA Packages with Electroless Nickel Immersion Gold (ENIG) Surface Finish Yong-Sung Park 1 ), Yong-Min Kwon 1 ), Ho-Young
NANO INDENTERS FROM MICRO STAR TECHNOLOGIES
NANO INDENTERS FROM MICRO STAR TECHNOLOGIES Micro Star makes a variety of nano indenters following defined standards or custom requested geometries and dimensions. Micro Star calibration laboratory complies
COMPOSITE MATERIALS. Asst. Prof. Dr. Ayşe KALEMTAŞ
COMPOSITE MATERIALS Office Hours: Tuesday, 16:30-17:30 [email protected], [email protected] Phone: +90 252 211 19 17 Metallurgical and Materials Engineering Department ISSUES TO ADDRESS Classification
THE DETERMINATION OF DELAMINATION STRAIN ENERGY RELEASE RATE OF COMPOSITE BI-MATERIAL INTERFACE
THE DETERMINATION OF DELAMINATION STRAIN ENERGY RELEASE RATE OF COMPOSITE BI-MATERIAL INTERFACE Jaroslav Juracka, Vladimir Matejak Brno University of Technology, Institute of Aerospace Engineering [email protected];
Effect of Temperature and Aging Time on 2024 Aluminum Behavior
Proceedings of the XIth International Congress and Exposition June 2-5, 2008 Orlando, Florida USA 2008 Society for Experimental Mechanics Inc. Effect of Temperature and Aging Time on 2024 Aluminum Behavior
Unit 6: EXTRUSION. Difficult to form metals like stainless steels, nickel based alloys and high temperature metals can also be extruded.
1 Unit 6: EXTRUSION Introduction: Extrusion is a metal working process in which cross section of metal is reduced by forcing the metal through a die orifice under high pressure. It is used to produce cylindrical
CH 6: Fatigue Failure Resulting from Variable Loading
CH 6: Fatigue Failure Resulting from Variable Loading Some machine elements are subjected to static loads and for such elements static failure theories are used to predict failure (yielding or fracture).
Selective Laser Sintering of Duraform TM Polyamide with Small-Scale Features
Selective Laser Sintering of Duraform TM Polyamide with Small-Scale Features Vinay Sriram, Kristin Wood, David Bourell and Joseph J Beaman Department of Mechanical Engineering Laboratory of Freeform Fabrication
Friction Surfacing of Austenitic Stainless Steel on Low Carbon Steel: Studies on the Effects of Traverse Speed
, June 30 - July 2, 2010, London, U.K. Friction Surfacing of Austenitic Stainless Steel on Low Carbon Steel: Studies on the Effects of Traverse Speed H. Khalid Rafi, G. D. Janaki Ram, G. Phanikumar and
Lab 1 Concrete Proportioning, Mixing, and Testing
Lab 1 Concrete Proportioning, Mixing, and Testing Supplemental Lab manual Objectives Concepts Background Experimental Procedure Report Requirements Discussion Prepared By Mutlu Ozer Objectives Students
Properties of Materials
CHAPTER 1 Properties of Materials INTRODUCTION Materials are the driving force behind the technological revolutions and are the key ingredients for manufacturing. Materials are everywhere around us, and
AUSTENITIC STAINLESS DAMASCENE STEEL
AUSTENITIC STAINLESS DAMASCENE STEEL Damasteel s austenitic stainless Damascene Steel is a mix between types 304L and 316L stainless steels which are variations of the 18 percent chromium 8 percent nickel
Solution for Homework #1
Solution for Homework #1 Chapter 2: Multiple Choice Questions (2.5, 2.6, 2.8, 2.11) 2.5 Which of the following bond types are classified as primary bonds (more than one)? (a) covalent bonding, (b) hydrogen
Scanning Electron Microscopy Services for Pharmaceutical Manufacturers
Scanning Electron Microscopy Services for Pharmaceutical Manufacturers Author: Gary Brake, Marketing Manager Date: August 1, 2013 Analytical Testing Laboratory www.atl.semtechsolutions.com Scanning Electron
Use of Strain Gauge Rosette to Investigate Stress concentration in Isotropic and Orthotropic Plate with Circular Hole
Use of Strain Gauge Rosette to Investigate Stress concentration in Isotropic and Orthotropic Plate with Circular Hole Mr.V.G.Aradhye 1, Prof.S.S.Kulkarni 2 1 PG Scholar, Mechanical department, SKN Sinhgad
EXPERIMENTAL AND NUMERICAL ANALYSIS OF THE COLLAR PRODUCTION ON THE PIERCED FLAT SHEET METAL USING LASER FORMING PROCESS
JOURNAL OF CURRENT RESEARCH IN SCIENCE (ISSN 2322-5009) CODEN (USA): JCRSDJ 2014, Vol. 2, No. 2, pp:277-284 Available at www.jcrs010.com ORIGINAL ARTICLE EXPERIMENTAL AND NUMERICAL ANALYSIS OF THE COLLAR
Structural Integrity Analysis
Structural Integrity Analysis 1. STRESS CONCENTRATION Igor Kokcharov 1.1 STRESSES AND CONCENTRATORS 1.1.1 Stress An applied external force F causes inner forces in the carrying structure. Inner forces
CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS
AN ERGONARMOR COMPANY TECHNICAL INFORMATION SPECIFICATION FOR INSTALLATION 07/11 SUPERSEDES 04/00 PAGE 1 OF 6 CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS 1. SCOPE 1.1 This specification
Microscopy and Nanoindentation. Combining Orientation Imaging. to investigate localized. deformation behaviour. Felix Reinauer
Combining Orientation Imaging Microscopy and Nanoindentation to investigate localized deformation behaviour Felix Reinauer René de Kloe Matt Nowell Introduction Anisotropy in crystalline materials Presentation
AISI O1 Cold work tool steel
T OOL STEEL FACTS AISI O1 Cold work tool steel Great Tooling Starts Here! This information is based on our present state of knowledge and is intended to provide general notes on our products and their
PROPERTIES OF MATERIALS
1 PROPERTIES OF MATERIALS 1.1 PROPERTIES OF MATERIALS Different materials possess different properties in varying degree and therefore behave in different ways under given conditions. These properties
MICRO PLASTICS MOLDED NYLON 6/6 FASTENERS MECHANICAL TEST DATA - UNC - UNF SECTION
MICRO PLASTICS MOLDED NYLON 6/6 FASTENERS MECHANICAL TEST DATA - UNC - UNF Nylon 6/6 meets MIL-M20693B "A" Type 1, LP410A, and ASTM D789-66 Type 1, GDE 2 All test performed per ASTM specifications. Parts
Tensile Testing Laboratory
Tensile Testing Laboratory By Stephan Favilla 0723668 ME 354 AC Date of Lab Report Submission: February 11 th 2010 Date of Lab Exercise: January 28 th 2010 1 Executive Summary Tensile tests are fundamental
STAVAX SUPREME. Stainless tool steel
STAVAX SUPREME Stainless tool steel General Demands placed on plastic mould tooling are increasing. Such conditions require mould steels that possess a unique combination of toughness, corrosion resistance
University of Portland School of Engineering LABORATORY OUTLINE: TENSILE TESTING OF STEEL & ALUMINUM ALLOYS (ASTM E8)
TENSILE TESTING OF STEEL & ALUMINUM ALLOYS (ASTM E8) To carry out a standard tensile test on specimens of a hot rolled steel (AISI 1045), Type 2024- T351 aluminum, polymers (UHMW-PE, acrylic) and, from
TechCut 4 Precision Low Speed Saw
Product Brochure TechCut 4 Precision Low Speed Saw 3" - 6" Blade Range Digital Speed Display 1-Micron Sample Indexing Spring-Loaded Dressing Stick Attachment All Aluminum & Stainless Steel Construction
M n = (DP)m = (25,000)(104.14 g/mol) = 2.60! 10 6 g/mol
14.4 (a) Compute the repeat unit molecular weight of polystyrene. (b) Compute the number-average molecular weight for a polystyrene for which the degree of polymerization is 25,000. (a) The repeat unit
THE COMPOSITE DISC - A NEW JOINT FOR HIGH POWER DRIVESHAFTS
THE COMPOSITE DISC - A NEW JOINT FOR HIGH POWER DRIVESHAFTS Dr Andrew Pollard Principal Engineer GKN Technology UK INTRODUCTION There is a wide choice of flexible couplings for power transmission applications,
Lecture 18 Strain Hardening And Recrystallization
-138- Lecture 18 Strain Hardening And Recrystallization Strain Hardening We have previously seen that the flow stress (the stress necessary to produce a certain plastic strain rate) increases with increasing
TENSILE TESTING PRACTICAL
TENSILE TESTING PRACTICAL MTK 2B- Science Of Materials Ts epo Mputsoe 215024596 Summary Material have different properties all varying form mechanical to chemical properties. Taking special interest in
ANALYSIS OF THE FATIGUE STRENGTH UNDER TWO LOAD LEVELS OF A STAINLESS STEEL BASED ON ENERGY DISSIPATION
EPJ Web of Conferences 6, 6 38009 (00) DOI:0.05/epjconf/000638009 Owned by the authors, published by EDP Sciences, 00 ANALYSIS OF THE FATIGUE STRENGTH UNDER TWO LOAD LEVELS OF A STAINLESS STEEL BASED ON
Araldite AV 170. Advanced Materials. One component epoxy adhesive. Structural Adhesives. Key properties. Description. Product data.
Advanced Materials Araldite AV 170 Structural Adhesives Araldite AV 170 One component epoxy adhesive Key properties Cures at 140-180 C Heat resistant to 120 C Very good peel strength Good chemical resistance
Long term performance of polymers
1.0 Introduction Long term performance of polymers Polymer materials exhibit time dependent behavior. The stress and strain induced when a load is applied are a function of time. In the most general form
Dr Marcin Adamiak marcin.adamiak. www.imiib.polsl.pl/
FP7 NMP/INCO Brokerage Event Warsaw, 17-18 September 2009 Dr Marcin Adamiak marcin.adamiak [email protected] http://www.imiib.polsl.pl www.imiib.polsl.pl/ Institute of Engineering Materials and Biomaterials
Experimental assessment of concrete damage due to exposure to high temperature and efficacy of the repair system
MATEC Web of Conferences 6, 06002 (2013) DOI: 10.1051/matecconf/20130606002 C Owned by the authors, published by EDP Sciences, 2013 Experimental assessment of concrete damage due to exposure to high temperature
SALT SPRAY AND IMMERSION CORROSION TESTING OF PM STAINLESS STEEL MATERIALS. W. Brian James Hoeganaes Corporation. Cinnaminson, NJ 08077
SALT SPRAY AND IMMERSION CORROSION TESTING OF PM STAINLESS STEEL MATERIALS W. Brian James Hoeganaes Corporation Cinnaminson, NJ 08077 Leander F. Pease III Powder-Tech Associates Inc. Andover, MA 01845
X15TN TM. A high hardness, corrosion and fatigue resistance martensitic grade CONTINUOUS INNOVATION RESEARCH SERVICE.
TM A high hardness, corrosion and fatigue resistance martensitic grade CONTINUOUS METALLURGICAL SPECIAL STEELS INNOVATION RESEARCH SERVICE DEVELOPMENT Enhancing your performance THE INDUSTRIAL ENVIRONMENT
VeMet, Utrecht, NL «Solution in Wear Protection» 26.10.2011 Dipl.-Ing. Wolfgang Leichnitz. Quit
VeMet, Utrecht, NL «Solution in Wear Protection» 26.10.2011 Dipl.-Ing. Wolfgang Leichnitz Quit Theory and Practice of Wear Definition In materials science, wear is the erosion of material from a solid
Lecture slides on rolling By: Dr H N Dhakal Lecturer in Mechanical and Marine Engineering, School of Engineering, University of Plymouth
Lecture slides on rolling By: Dr H N Dhakal Lecturer in Mechanical and Marine Engineering, School of Engineering, University of Plymouth Bulk deformation forming (rolling) Rolling is the process of reducing
Testing and appraisal of Lucobit polymer effect as an additive on asphalt mixture performance
Abstract Testing and appraisal of polymer effect as an additive on asphalt mixture performance Hamid Sabbagh mollahosseini*,golazin Yadollahi**, Ershad Amoosoltani*** *, ***Executive of Engineering and
Technical Data Sheet February 2014
Scotch-Weld Technical Data Sheet February 2014 Product Description s are high performance, two-part acrylic adhesives that offer excellent shear, peel, and impact performance. These toughened products
Environmental Stress Crack Resistance of Polyethylene Pipe Materials
Environmental Stress Crack Resistance of Polyethylene Pipe Materials ROBERT B. TAMPA, Product Development and Service Engineer* Abstract Slow crack growth is a phenomenon that can occur in most plastics.
The Mechanical Properties of Glass
The Mechanical Properties of Glass Theoretical strength, practical strength, fatigue, flaws, toughness, chemical processes Glass Engineering 150:312 Professor Richard Lehman Department of Ceramics and
Tableting Punch Performance Can Be Improved With Precision Coatings
Tableting Punch Performance Can Be Improved With Precision Coatings by Arnold H. Deutchman, Ph. D. Director of Research and Development (614) 873-4529 X 114 [email protected] Mr. Dale C. Natoli
GRADATION OF AGGREGATE FOR CONCRETE BLOCK
GRADATION OF AGGREGATE FOR CONCRETE BLOCK Although numerous papers have been written concerning the proper gradation for concrete mixes, they have generally dealt with plastic mixes, and very little published
A STUDY ON BONDING STRENGTH OF POLYMERIC FIBERS TO CEMENTITIOUS MATRIX
CD01-006 A STUDY ON BONDING STRENGTH OF POLYMERIC FIBERS TO CEMENTITIOUS MATRIX H.R. Pakravan 1, M. Jamshidi 2, M. Latifi 3 1 M.Sc. student, Textile Engineering Department, Amirkabir University, Tehran,
Uniaxial Tension and Compression Testing of Materials. Nikita Khlystov Daniel Lizardo Keisuke Matsushita Jennie Zheng
Uniaxial Tension and Compression Testing of Materials Nikita Khlystov Daniel Lizardo Keisuke Matsushita Jennie Zheng 3.032 Lab Report September 25, 2013 I. Introduction Understanding material mechanics
SHORE A DUROMETER AND ENGINEERING PROPERTIES
SHORE A DUROMETER AND ENGINEERING PROPERTIES Written by D.L. Hertz, Jr. and A.C. Farinella Presented at the Fall Technical Meeting of The New York Rubber Group Thursday, September 4, 1998 by D.L. Hertz,
ADHESIVE BONDING PERFORMANCE OF GA COATED 590 MPa TENSILE STRENGTH STEELS
ADHESIVE BONDING PERFORMANCE OF GA COATED 590 MPa TENSILE STRENGTH STEELS Susan Wolf ArcelorMittal Global R&D East Chicago Acknowledgements Chann Cheng, Benda Yan, Jayanth Chintamani, ArcelorMittal Global
Wax-based binder for low-pressure injection molding and the robust production of ceramic parts
Wax-based binder for low-pressure injection molding and the robust production of ceramic parts J. E. Zorzi a,* C. A. Perottoni b,a, J. A. H. da Jornada c,a a Universidade Federal do Rio Grande do Sul,
3M Thermal Bonding Film AF42
Technical Data August 2015 3M Thermal Bonding Film AF42 Product Description 3M Thermal Bonding Film AF42 is an epoxy, thermoset film adhesive developed for structural bonding of metal, glass and other
Objective To conduct Charpy V-notch impact test and determine the ductile-brittle transition temperature of steels.
IMPACT TESTING Objective To conduct Charpy V-notch impact test and determine the ductile-brittle transition temperature of steels. Equipment Coolants Standard Charpy V-Notched Test specimens Impact tester
METU DEPARTMENT OF METALLURGICAL AND MATERIALS ENGINEERING
METU DEPARTMENT OF METALLURGICAL AND MATERIALS ENGINEERING Met E 206 MATERIALS LABORATORY EXPERIMENT 1 Prof. Dr. Rıza GÜRBÜZ Res. Assist. Gül ÇEVİK (Room: B-306) INTRODUCTION TENSION TEST Mechanical testing
KALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET
1 KALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET KI XL - 03 / KI-SC 10 TWO COMPONENT AMBIENT CURABLE POLYETHYLENE COMPOUND FOR INSULATION OF LOW VOLTAGE POWER CABLE DESCRIPTION : KI polyethylene compound
Crimp Tooling Where Form Meets Function
Crimp Tooling Where Form Meets Function Quality, cost, and throughput are key attributes for any production process. The crimp termination process is no exception. Many variables contribute to the results.
Apr 17, 2000 LAB MANUAL 1811.0
Apr 17, 2000 LAB MANUAL 1811.0 1811 BULK SPECIFIC GRAVITY (GMB) AND DENSITY OF COMPACTED BITUMINOUS SPECIMENS USING PARAFFIN OR PARAFILM ASTM Designation D 1188 (MN/DOT Modified) 1811.1 SCOPE This test
TECHNICAL DATA SHEET GRILON BG-15 S
TECHNICAL DATA SHEET GRILON BG-1 S Grilon BG-1 S is a heat stabilised PA6 injection moulding grade with 1% glass fibres. Grilon BG-1 S has the following important properties: Excellent surface finish Easy
4 Thermomechanical Analysis (TMA)
172 4 Thermomechanical Analysis 4 Thermomechanical Analysis (TMA) 4.1 Principles of TMA 4.1.1 Introduction A dilatometer is used to determine the linear thermal expansion of a solid as a function of temperature.
DIRECT SHEAR TEST SOIL MECHANICS SOIL MECHANICS LABORATORY DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF MORATUWA SRI LANKA
DIRECT SHEAR TEST SOIL MECHANICS SOIL MECHANICS LABORATORY DEPARTMENT OF CIVIL ENGINEERING UNIVERSITY OF MORATUWA SRI LANKA DIRECT SHEAR TEST OBJEVTIVES To determine the shear strength parameters for a
Investigating Methods of Prototyping with ABS
Investigating Methods of Prototyping with ABS Ben Chapman, Shivam Desai, Mark Muraoka, Teodora Vidolova 1 Abstract In this comparative study of the mechanical properties of plastic parts produced by three
Inspired By Challenge. Technical information polymer characteristics
Inspired By Challenge Technical information polymer characteristics Technical Information Seat materials - overview Habonim s extensive field experience, which lets us design valves that meet the diverse
CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS
CONTRACT SPECIFICATIONS - SEISMIC ISOLATION BEARINGS 1.0 DESIGN 1.1 Scope of Work 1.1.1 This work shall consist of furnishing Isolation Bearings and installing Isolation Bearing Assemblies at the locations
INVESTIGATION OF VISCOELASTICITY AND CURE SHRINKAGE IN AN EPOXY RESIN DURING PROCESSING
TH INTERNATIONAL CONFERENCE ON COMPOSITE MATERIALS INVESTIGATION OF VISCOELASTICITY AND CURE SHRINKAGE IN AN EPOXY RESIN DURING PROCESSING T. Shimizu *, H. Koinuma, K. Nagai Mitsubishi Heavy Industries,
