3.2 Testing and inspection organisation 6
|
|
|
- Mavis Phelps
- 9 years ago
- Views:
Transcription
1 GUIDE YVL 5.7 / 28 Ap r i l 2008 Nuclear facility pump units 1 Pr e fa c e 5 2 Definitions 5 3 Manufacturer, testing and inspection organisation Manufacturer Testing and inspection organisation 6 4 General pump unit requirements 6 5 Pump specification 7 6 Pump construction plan General requirements Manufacturer and testing organisation Operating experience and type test data Design basis Dimensioning General requirements Strength calculations Hydraulic analyses Other dimensioning Technical specifications Inspection plan Inspection procedures Spare parts 10 continues As regards new nuclear facilities, this guide is valid as of 1 November 2008 until further notice. At operating nuclear facilities, and those under construction, this guide is enforced by a separate STUK decision. This guide replaces Guide YVL 5.7, issued on 23 November Fourth, revised edition Helsinki 2009 ISSN ISBN (print) Edita Prima Oy 2009 ISBN (pdf) ISBN (html) STUK SÄTEILYTURVAKESKUS STRÅLSÄKERHETSCENTRALEN RADIATION AND NUCLEAR SAFETY AUTHORITY Osoite/Address Laippatie 4, Helsinki Postiosoite / Postal address PL / P.O.Box 14, FIN Helsinki, FINLAND Puh./Tel. (09) , Fax (09) ,
2 GUIDe YVL 5.7 / 28 Ap r i l Electric motor construction plan General requirements Manufacturer and testing organisation Operating experience and type test data Design basis Dimensioning General requirements Electrotechnical calculations Strength calculations Bearings Technical specifications Inspection plan Inspection procedures Spare parts 11 8 Inspections and testing General requirements Construction inspection Type test 12 9 Inst allation General requirements Installation plan Installation inspection Commissioning General requirements Commissioning inspection Phase Phase Operation, maintenance and modifications Oversight by STUK General Pump specification Construction plans General Pump construction plan Electric motor construction plan Inspections and testing Installation Commissioning Operation, maintenance and modifications Re fe r e n c e s 16
3 Authorisation By virtue of the below acts and regulations, the Finnish Radiation and Nuclear Safety Authority (STUK) issues detailed regulations that apply to the safe use of nuclear energy and to physical protection, emergency preparedness and safeguards: section 55 of the Nuclear Energy Act (990/1987) section 29 of the Government Decision (395/1991) on the safety of nuclear power plants section 13 of the Government Decision (396/1991) on the physical protection of nuclear power plants section 11 of the Government Decision (397/1991) on the emergency preparedness of nuclear power plants section 8 of the Government Decision (398/1991) on the safety of a disposal facility for reactor waste section 30 of the Government Decision (478/1999) on the safety of disposal of spent nuclear fuel. Rules for application The publication of a YVL guide does not, as such, alter any previous decisions made by STUK. It is only after having heard those concerned that STUK makes a separate decision on how a new or revised YVL guide applies to operating nuclear power plants, or those under construction, and to licensees operational activities. The guides apply as such to new nuclear facilities. When considering how new safety requirements presented in YVL guides apply to operating nuclear power plants, or to those under construction, STUK takes into consideration section 27 of the Government Decision (395/1991), which prescribes that for further safety enhancement, action shall be taken which can be regarded as justified considering operating experience and the results of safety research, as well as the advancement of science and technology. If deviations are made from the requirements of the YVL guides, STUK shall be presented with some other acceptable procedure or solution by which the safety level set forth in the YVL guides is achieved. Translation. Original text in Finnish.
4
5 GUIDe YVL 5.7 / 28 Ap r i l Preface This guide presents the requirements for a nuclear facility s pumps and their electric motor drives placed by STUK on the licensee and the procedures by which STUK oversees compliance with these requirements. This guide applies to pumps in Safety Classes 1, 2, 3 and 4 and their electric motors in Safety Classes 2 and 3 as follows: design and dimensioning manufacturing control, inspection and testing installation and commissioning maintenance, modifications and repairs. The licensee shall have available corresponding procedures for the procurement, operation and maintenance of pumps in Class EYT (nonnuclear) and their electric motors in Safety Class 4 and Class EYT. This guide is primarily intended for centrifugal pumps and their electric motor drives. However, where applicable the requirements and control procedures given apply equally to the nuclear facility s other types of pumps and their drives. 2 Definitions The following abbreviations and definitions are used in this guide: auxiliaries a device that is part of the structure and functioning of a pump or an electric motor, such as gears, couplings, operating speed regulators, parts of the cooling, sealing and lubrication systems, supports, fastening and anchor bolts, bottom plates, local adjustment and protection devices non-serial order-specific, entirely new or modified from a component that has been in service hold point a notified inspection or test beyond which activities must not proceed without witnessing by STUK or a STUK-approved inspection organisation centrifugal pump a dynamic radial, axial and semi-axial pump STUK wearing spare parts spare parts and materials (seals, bearings, lubricants, etc.) replaced during preventive maintenance major subcontractor a subcontractor who manufactures, e.g., a pump casing, a pump impeller, a pump shaft, an electric motor shaft or a corresponding structurally significant pump unit component NPSH a net positive suction head available at pump inlet nozzle NPSH r net positive suction head required at pump inlet nozzle pump a pump and its auxiliaries; gears, couplings and other such equipment between pump and electric motor are considered pump auxiliaries pump unit a pump and electric motor reference pump or electric motor similar to the manufactured pump or electric motor by construction, operating values and operating environment serial manufactured in series (identical or similar materials, manufacturing methods, parts, structures and operating values) and has been in service strategic spare parts replacement parts whose availability ensures operability of pump unit (impeller, pump, electric motor, etc.) design conditions design basis operational conditions, transients and accidents as well as design basis ambient conditions (temperature, humidity, radiation, pressure difference, characteristics of pumped liquid, etc.) electric motor an electric motor and its auxiliaries testing organisation performs non-destructive or destructive materials testing product class based on the design work required for the pump unit, previous manufacturing volumes 5
6 STUK GUIDe YVL 5.7 / 28 Ap r i l 2008 and operating experience, a product is classified as either serial or non-serial witness point a notified inspection or test beyond which activities can proceed without witnessing by STUK or a STUK-approved inspection organisation. 3 Manufacturer, testing and inspection organisation 3.1 Manufacturer Pump and electric motor manufacturer must have competent and experienced personnel facilities and equipment for manufacturing as well as qualified manufacturing methods systematic procedures for assessing, selecting and supervising subcontractors references to pumps and electric motors with similar operating parameters and structures a management system that fulfils the requirements of Guide YVL 1.4 Management systems for nuclear facilities. The manufacturer or the subcontractor shall have STUK s approval in accordance with Guide YVL 3.4 Approval of the manufacturer of nuclear pressure equipment when they fabricate pump unit s pressure-retaining structures by permanent joining, heat treatment or forming. The acceptability of the manufacturing methods of the pump unit s other structures is assessed by STUK or a STUK-approved inspection organisation based on the pump and electric motor construction plans and a possible audit at the manufacturer s premises. The manufacturer shall submit the following documents to the licensee: documents for pump unit pre-inspection, as required in the construction plan manufacturing and inspection records requirements and instructions for pump unit installation, commissioning, operation, maintenance, condition monitoring, in-service inspection and testing, and ageing management. 3.2 Testing and inspection organisation The testing organisation and inspection organisation performing pump unit materials testing, and whose duties relate to the conformity assessment and approval of design and manufacturing, shall be STUK-approved in accordance with Guide YVL 1.3 Mechanical components and structures of nuclear facilities. Approval of testing and inspection organisations. 4 General pump unit requirements Pump unit design, dimensioning, manufacturing and fabrication, inspection and testing shall be based on generally used component and nuclear engineering standards [1 18]. The integrity of the pump unit s pressure retaining parts is to be maintained and the pump unit is to fulfil the system s operational requirements under design conditions for the duration of its design service life. This shall be demonstrated by calculations, tests and previous operational experience data. Where separate strength calculations are not required the dimensioning of pressure retaining structures or other load bearing structures shall be based on applicable standards. Pump unit materials shall be applicable for their intended use. Material properties with their manufacturing tolerances must fulfil the requirements of design conditions and related phenomena such as fatigue, wearing, corrosion, cavitation and radioactivity of medium. The materials and welding filler materials of pressure retaining structures shall be approved and their material properties verified in accordance with Guide YVL 3.9 Nuclear power plant pressure equipment. Construction and welding filler materials. The pump unit shall fulfil the following requirements: It must have a design basis operating lifetime of at least three years of uninterrupted operation, with the exception of wearing spare parts. Pump unit structure, location and process environment shall allow the performance of 6
7 GUIDe YVL 5.7 / 28 Ap r i l 2008 STUK regular maintenance work, in-service inspection and testing. Pump unit performance and condition monitoring (e.g. bearing, shaft seals, lubrication, cooling) shall be possible during operation. The monitoring of a Safety Class 1 or 2 pump shall be possible at the nuclear facility s main or local control room. Start-up and stopping must not cause undue wear or strain on the pump unit structures. Planned and unplanned leaks from a pump pumping radioactive liquid must be controllably led to a drain collection system. The pump must have a decreasing head within its operating range. The pump s available suction head NPSHa must be adequate to ensure undisturbed operation under design conditions. The pump must have wearing rings, or equivalent devices, to prevent loss of integrity in failures leading to rotor displacement. 5 Pump specification The licensee shall have a nuclear facility and safety class specific pump specification defining the general requirements for the nuclear facility s pump units as follows: design basis structural and functional dimensioning inspection plan inspection procedures manufacturer-related requirements. Of the design basis and dimensioning, the following shall be presented: the design conditions of the nuclear facility s pump units; the requirements set for their materials, structures and functioning; and the component and nuclear engineering standards used in dimensioning. The inspection plan shall define the inspections and testing to be performed on the materials, structures and functioning of the pump unit and its electric motor during manufacturing, fabrication and factory acceptance tests. In the inspection procedures, the performance, scope and approval criteria of the most important inspections and tests shall be given. Requirements pertaining to the manufacturer shall describe the requirements set for the quality management, previous nuclear facility experience, expertise and delivery references of the manufacturer of the pump and electric motor. 6 Pump construction plan 6.1 General requirements The following information shall be given in the pump s construction plan: tag (KKS code or equivalent), safety class and product class manufacturer and testing organisation previous operating experience design basis dimensioning calculations technical specifications inspection plan inspection procedures spare parts. In accordance with Guide YVL 1.2 Documents pertaining to safety control of nuclear facilities, the licensee shall submit to STUK in three copies the construction plan they have approved. To a STUK-approved inspection organisation, a similarly approved plan shall be submitted using a procedure required by the organisation. 6.2 Manufacturer and testing organisation If the pump s manufacturer or a major subcontractor is STUK-approved, the construction plan shall contain references to the relevant STUK decisions and their expiration dates. Otherwise, of manufacturers of Safety Class 1 and 2 valve units, the corporate structure (parent company/ companies, design and manufacturing organisation), management system description, management system quality certificates, major subcontractors and previous references shall be given. Of manufacturers of Safety Class 3 and 4 valve units, at least the management system quality certificates and previous references shall be given. For non-serial Safety Class 1 or 2 pumps, manufacturing and repair methods of importance and their qualification data shall be given. As regards approval of testing organisations, the construction plan shall contain references to the relevant STUK decisions and their expiration 7
8 STUK GUIDe YVL 5.7 / 28 Ap r i l 2008 dates If the testing organisation is accredited, documents proving the accreditation submitted earlier to STUK for information shall be referred to. 6.3 Operating experience and type test data The types, rated values, quantities, delivery years, purchasers and type test reports of reference pumps shall be given. When the construction or functioning of a pump differs from the reference pumps, information shall be given that makes it possible to evaluate the effect of the differences. For Safety Class 1 and 2 reference pumps, operating experience data should include operating times and conditions with fault and maintenance history information. 6.4 Design basis As the design basis, the requirements set for the pump by the system and the environment under design conditions shall be presented as follows: flow, head and NPSH calculations a mechanical loadings and their combinations design pressure and temperature forces and torques exerted by piping forces and torques exerted by electric motor dynamic loadings (periodic operation, pressure and temperature transients) external dynamic loadings (seismic event, aircraft impact, pressure wave) liquid properties ambient conditions (temperature, humidity, radiation, etc.) integrity and operability requirements under design conditions service life decontamination. 6.5 Dimensioning General requirements The design and dimensioning standards used shall be referred to. Dimensioning calculations shall be presented covering initial data, calculation methods, visualised results, acceptance criteria and conclusions Strength calculations Safety Classes 1 and 2 For Safety Class 1 and 2 pumps, strength calculations shall be given as follows: basic dimensioning casing and nozzles load transfer parts frame structures components subject to centrifugal loading pressure retaining or other load bearing auxiliaries supports and anchoring bolts fatigue analysis for structures subject to fatigue induced by alternate loading stress analysis for pressure retaining main structures (Safety Class 1 pump) a fast fracture analysis for pressure retaining main structures and flywheel (Safety Class 1 pump). Strength analysis requirements are presented in Guide YVL 3.5 Ensuring the strength of pressure equipment at nuclear facilities. Strength calculations are not required for a serial pump with a rated output less than 15 kw (electric motor) unless required by its special construction or operation. Safety Classes 3 and 4 For a Safety Class 3 or 4 non-serial pump, basic dimensioning of pump casing, suction and discharge nozzles as well as supports and anchoring bolts shall be presented. Basic dimensioning is not required for serial pumps unless required by their special construction or operation Hydraulic analyses When the intake of a pump, or a number of pumps, is located in an open tank, the hydraulic dimensioning of the system shall be verified by mock-up tests or sound hydraulic operation of the system under design conditions shall be otherwise demonstrated. For a Safety Class 1 pump, flow characteristics shall be analysed by means of three dimensional computational fluid dynamics. Analyses shall be used in the pump design to ensure favou- 8
9 GUIDe YVL 5.7 / 28 Ap r i l 2008 STUK rable velocity and pressure fields, e.g. over the impeller and guide vanes, and ultimately to estimate pump performance head vs. flow. Results of the design point analyses shall be presented to a minimum Other dimensioning For a Safety Class 1 or 2 pump unit (serial pumps with an electric motor having a rated output less than 15 kw excluded) or a non-serial Safety Class 3 or 4 pump, the following dimensioning data shall be given: vibration analysis analysis of operational clearances dimensioning of bearing and shaft seals. The aforementioned data is not required for other pump units, unless required by their special construction or operation. A vibration analysis shall present calculations for pump unit dynamics or equivalent justification to demonstrate that the margin between natural frequencies and excitations as well damping is adequate to ensure sound pump unit operation under design conditions. The analysis shall cover pump unit rotating components (torsional vibrations and lateral vibrations) and static main structures. Dimensioning data for operational clearances and plays to allow thermal expansion shall be presented to demonstrate their adequacy under design conditions. Selection criteria for bearings and shaft seals,shall be presented to demonstrate their structural and functional acceptability under design conditions. 6.6 Technical specifications The following technical specifications for the pump shall be given: characteristic curves (whole control range when speed controlled pump) head, NPSHr, shaft power and efficiency vs. flow torque vs. rotation speed minimum and maximum flow with associated time limits assembly and sectional drawings drawings of auxiliaries (shaft seal, bearing, coupling, gear etc.) part list and construction materials welding materials material specifications of major structural parts (Safety Classes 1 and 2) instrument list interlockings, protections, alarm and trip limits pump unit start-up procedure flow rate, temperature and quality requirements for cooling water and shaft seal water. Drawings shall present main dimensions, refer to the part list and material specifications and also indicate welded joints and hardfacings. The drawings shall also show the operation of the pump as well as essential tolerances, clearances and plays. A process and instrument diagram shall be given when the pump unit has such instrumented auxiliaries as lube oil, shaft seal and cooling systems. 6.7 Inspection plan An inspection plan for the inspection and testing of the materials, structures and operation of the pump shall be presented. It defines inspection and test steps as well as their supervision whose scope depends on the pump s safety significance. For the performance of the inspections and testing, the inspection plan shall refer to relevant inspection procedures and/or standards and include STUK or a STUK-approved inspection organisation hold and witness points. 6.8 Inspection procedures Procedures to inspect and test pump materials, structures and operation shall be drawn up or applicable standards be used as such procedures. The inspection procedures shall include instructions, scope and approval criteria for the performance of the inspections and tests. Inspection procedures shall be presented at least for hydrostatic and leaktightness tests, functional tests (performance test, endurance test and other functional tests), and, in Safety Classes 1 and 2 for a pump s DT and NDT testing (material manufacturing and pump fabrication) and rotor balancing. A reference to the relevant decisions is adequate for inspection procedures approved by STUK earlier. 9
10 STUK GUIDe YVL 5.7 / 28 Ap r i l Spare parts The construction plan shall define those wearing spare parts and strategic spare parts of the pump that are available, where necessary, at the nuclear facility or stored elsewhere for maintenance and repair work. 7 Electric motor construction plan 7.1 General requirements The following information shall be contained in the electric motor s construction plan: tag (KKS code or equivalent), safety class and product class manufacturer and testing organisation previous operating experience design basis dimensioning calculations technical specifications inspection plan inspection procedures spare parts. In accordance with Guide YVL 1.2 Documents pertaining to safety control of nuclear facilities, the licensee shall submit to STUK in three copies the construction plan they have approved. To a STUK-approved inspection organisation, a similarly approved plan shall be submitted using a procedure required by the organisation. 7.2 Manufacturer and testing organisation Of the manufacturer of a Safety Class 2 electric motor, the corporate structure (parent company/ companies, design and manufacturing organisation), management system description, management system quality certificates, major subcontractors and previous references shall be given. Of manufacturers in Safety Class 3, at least the management system quality certificates and previous references shall be given. As regards approval of testing organisations, the construction plan shall contain references to the relevant STUK decisions and their expiration dates. If the testing organisation is accredited, documents proving the accreditation submitted earlier to STUK for information shall be referred to. 7.3 Operating experience and type test data The types, rated values, quantities, delivery years, purchasers and type test reports of reference electric motors shall be given. When the construction or functioning of the electric motor differs from the reference electric motor, information shall be given that makes it possible to evaluate the effect of the differences. For Safety Class 2 reference electric motors, operating experience data should include operating times and conditions with fault and maintenance history information. 7.4 Design basis As the design basis, the requirements set for the electric motor by pump, the system, the electrical grid and the environment under design conditions shall be presented as follows: pump mechanical power and rotation speed range and duration of supply voltage and frequency number of repeated start-ups mechanical loadings and their combinations mechanical design parameters exceptional reclosing design pressure and temperature (wet motor) external dynamic loadings (seismic event, aircraft impact, pressure wave) ambient conditions (temperature, humidity, radiation, etc.) moments of inertia of pump and coupling functional requirements under design conditions service life. 7.5 Dimensioning General requirements The design and dimensioning standards used shall be referred to. Dimensioning calculations shall be presented covering initial data, calculation methods, visualised results, acceptance criteria and conclusions Electrotechnical calculations For a Safety Class 2 electric motor, coil temperature rise calculations shall be presented. 10
11 GUIDe YVL 5.7 / 28 Ap r i l 2008 STUK Calculations are not needed for Safety Class 3 electric motors unless required by their special construction or functioning Strength calculations For a Safety Class 2 electric motor (serial electric motors having a rated output less than 15 kw excluded) or for a non-serial Safety Class 3 electric motor, strength calculations shall be given. Strength calculations are not needed for other electric motors unless required by their special construction or operation. The electric motor s strength calculations shall include basic dimensioning for the following components: load bearing or transferring parts, e.g. a shaft supports and anchoring bolts pressure retaining components, e.g. a wet motor shell Bearings For a Safety Class 2 electric motor (serial electric motors having a rated output less than 15 kw excluded) or a non-serial Safety Class 3 electric motor, bearing dimensioning data shall be given. Bearing dimensioning data is not required for other electric motors unless required by their special construction or operation. Selection criteria for bearings shall be presented to demonstrate their structural and functional acceptability under design conditions. 7.6 Technical specifications The following technical specifications for the electric motor shall be given: rated values torque curve (torque exerted by electric motor and pump countertorque) vs. rotation speed start-up times and longest allowable lockedrotor times assembly and sectional drawings part list and construction materials instrument list enclosure, temperature rise and insulation classes interlockings, protections, alarm and trip limits cooling water volume, temperature and quality requirements. Electric motor torque with rated voltage as well as with undervoltages and over frequencies shall be presented. Drawings shall present main dimensions, refer to the part list and material specifications and also indicate welded joints and hardfacings. The drawings shall also show essential operational tolerances, clearances and plays. Process and instrument diagrams shall be given when the electric motor has such instrumented auxiliaries as lube oil and cooling systems. 7.7 Inspection plan An inspection plan for the inspection and testing of the materials, structures and functioning of the electric motor shall be presented. It defines inspection and test steps as well as their supervision whose scope depends on the electric motor s safety significance. For the performance of the inspections and testing, the inspection plan shall refer to relevant inspection procedures and/or standards and include STUK or STUK-approved inspection organisation hold and witness points. 7.8 Inspection procedures Procedures to inspect and test electric motor materials, structures and functioning shall be drawn up or applicable standards be used as such procedures. The inspection procedures shall include instructions, scope and approval criteria for the performance of the inspections and tests. Inspection procedures shall be presented at least for factory tests (routine tests and other functional tests) and in Safety Class 2 (serial electric motors having a rated output less than 15 kw excluded) also for the DT and NDT testing (material manufacturing and motor fabrication) of electric motors, the insulation and impulse voltage testing of the coils of a medium voltage motor, and rotor balancing. A reference to the relevant decisions is adequate for inspection procedures approved by STUK earlier. 7.9 Spare parts The construction plan shall define those strategic spare parts and wearing spare parts of the electric motor that are available, where necessary, at the nuclear facility or stored elsewhere for maintenance and repair work. 11
12 STUK GUIDe YVL 5.7 / 28 Ap r i l Inspections and testing 8.1 General requirements The licensee shall ensure that the specified inspections and testing are performed on the materials, structures and functioning of the pump and electric motor, and make it possible for STUK or a STUK-approved inspection organisation to oversee manufacturing as well as the inspections and testing in the scope they deem necessary. The licensee shall arrange the pump unit s construction inspection as well as the other hold and witness points defined in the approved inspection plan or whose performance is otherwise required. 8.2 Construction inspection In accordance with the principles set out in Guide YVL 1.15 Mechanical components and structures in nuclear installations. Construction inspection, the construction inspections of pumps and electric motors are intended to ensure that materials, manufacturing, fabrication, structures and functioning comply with the approved construction plan the scope of inspections and tests comply with the approved inspection plan and their results are acceptable. In the construction inspection, the pump with part markings is visually inspected, the procurement and fabrication documentation is reviewed and appropriate tests witnessed. The tests to be witnessed are the pump s hydrostatic, leaktightness and functional tests. Functional testing comprises both performance tests and endurance tests. The minimum length of an endurance test in Safety Classes 1 and 2 is 48 h and every pump is to be tested. In Safety Classes 3 and 4 a corresponding endurance test is to last at least for 12 hours and one pump out of every batch of identical pumps is to be tested at a minimum. Pumps shall be disassembled and parts visually inspected after the endurance tests. The scope of an electric motor s construction inspection is decided upon case-by-case during the construction plan review. An electric motor s construction inspection typically includes a visual inspection, a review of its procurement and fabrication documentation and a witnessing of factory tests. The procurement and fabrication documentation approved by those in charge and construction plans approved by STUK with their reference documents shall be available at the construction inspection. 8.3 Type test The pump and electric motor shall be tested in such a way that one or more electric motors per type are tested to demonstrate compliance with requirements. Type test may be replaced with information given in the construction plan (records of previous type tests, good operating experience) that similarly demonstrates the compliance. When a type test is required, pump or electric motor structures and functioning shall be tested in conditions similar to design conditions in such a way that compliance with the requirements can be justifiably concluded from the test results. A type test procedure shall be drawn up that gives the test instructions, scope and acceptance criteria. 9 Installation 9.1 General requirements Prior to installation, the licensee shall make an acceptance inspection to ensure that the pump and electric motor were delivered to the nuclear facility defect-free and are as specified in the construction plan. Records shall be kept of the acceptance inspection. If installation includes fabrication, e.g. welded nozzles, the organisation installing the pump unit shall be STUK-approved in accordance with Guide YVL 3.4 Approval of the manufacturer of nuclear pressure equipment. 9.2 Installation plan The licensee shall draw up a pump unit installation plan containing the following information: installation procedure and drawings, incl. tightening of threads qualified welding procedures if installation includes welding inspection plan of installation. 12
13 GUIDe YVL 5.7 / 28 Ap r i l 2008 STUK Where necessary, the installation inspection plan shall include installation steps for welding, alignment and other inspections to demonstrate acceptability of the pump unit s mechanical installation. 9.3 Installation inspection The licensee shall arrange an visual inspection to demonstrate acceptability of the pump unit s mechanical installation. Reports of inspections specified in the installation inspection plan are also reviewed during the installation inspection. 10 Commissioning 10.1 General requirements Manufacturers instructions shall be followed during the pump and electric motor s commissioning. The licensee shall arrange a separate twophased commissioning inspection of the pump unit whose first phase ensures the pump unit s trial run readiness and the second its readiness for operation. However, in case of a Safety Class 3 or 4 pump with an electric motor having a rated output less than 100 kw, and if the system the pump unit belongs to is subject to a commissioning inspection, the licensee may demonstrate the pump unit s acceptable readiness for operation during the system s commissioning in accordance with Guide YVL 2.5 The commissioning of a nuclear power plant. Before the pump unit is put into service, the licensee shall perform a commissioning inspection on its electric motor in accordance with Guide YVL 5.2 Electrical power systems and components at nuclear facilities Commissioning inspection Phase 1 The licensee shall demonstrate during Phase 1 that the inspections and testing relating to the installed pump unit s electrical and I&C systems have been acceptably performed. The licensee shall present a pump unit construction plan, a construction inspection protocol and an installation inspection protocol that have been approved. The manufacturer s commissioning procedures shall be presented as well Phase 2 The licensee shall perform a trial run during Phase 2 to demonstrate that the pump unit fulfils the functional requirements as part of the system. The licensee shall draw up for Phase 2 a pump unit trial run plan (incl. process arrangements, measured data, acceptance criteria, etc.). The licensee shall present the plan before Phase 2 is started. It shall be possible by means of the trial run to ascertain the pump unit s operability under design operational conditions. An uninterrupted trial run period is to be long enough to allow for the process to reach steady conditions; one hour duration is considered the minimum, however. During the trial run, condition monitoring reference values (electric parameters, vibrations, bearing temperatures, etc.) shall be recorded for the pump unit. 11 Operation, maintenance and modifications The licensee shall operate and maintain pumps and their electric motors in such a way that they fulfil their set requirements for the duration of their design lifetime. The licensee shall have in place procedures and plans for the operation and maintenance of the pumps and their electric motors (preventive maintenance, in-service inspection and testing, repairs). The procedures and plans shall be based on manufacturer requirements and recommendations as well as decisions given by authorities and shall be continually updated and developed based on accumulated operating experience. Preventive maintenance shall be timed so that, by the next scheduled maintenance, the remaining service hours of wearing parts always exceed the designed uninterrupted operation period without maintenance. Approved construction plans shall be complied with in spare parts procurement. 13
14 STUK GUIDe YVL 5.7 / 28 Ap r i l 2008 The pump unit shall be periodically inspected and tested unless operability can be verified online by other means. The licensee shall draw up construction, installation and trial run plans for repairs and modification and similarly arrange construction, installation and commissioning inspections. The plans and inspections shall, where applicable, correspond to those required for a new pump unit. The licensee shall maintain a data acquisition system where documents on modifications and maintenance works are recorded, and shall ensure that they are at STUK s disposal on request. The licensee shall have spare parts available for maintenance and repair work as defined in the pump unit construction plan. 12 Oversight by STUK 12.1 General By the procedures described in this guide STUK oversees the nuclear facility s Safety Class 1, 2, 3 and 4 pumps and their Safety Class 2 and 3 electric motors. STUK oversees the appropriateness and implementation of procedures which the licensee has prepared to procure, operate and maintain the nuclear facility s Safety Class EYT pumps and their Safety Class 4 and Class EYT electric motors. Upon the licensee s application STUK delegates, in accordance with Table 1, inspections of Safety Class 3 and 4 pumps and Safety Class 3 electric motors to the inspection organisations it has approved for the purpose. The licensee shall send a notification to STUK or a STUK-approved inspection organisation to perform inspections or supervise testing early enough before proposed date Pump specification A nuclear facility specific pump specification shall be STUK-approved before the the construction plans of pumps and their electric motors can be submitted for approval to STUK or a STUKapproved inspection organisation Construction plans General Construction plans shall be licensee-approved before their submission for approval to STUK or a STUK-approved inspection organisation and before the start of manufacturing Pump construction plan The construction plan shall be approved by STUK or a STUK-approved inspection organisation before the manufacturing of Safety Class 1 or 2 pumps (serial pumps having a rated output less than 15 kw excluded) or non-serial pumps. Manufacturing means here the manufacturing of a prefabricated or other part that essentially relates to the acceptability of the pump s structural or functional dimensioning. The construction plan of a serial pump shall be approved by STUK or a STUK-approved inspection organisation before construction inspection if the electric motor s rated output is less than 15 kw or the pump belongs to Safety Class 3 or 4. A STUK-approved system level design basis for the pump is a prerequisite for construction plan approval Electric motor construction plan The construction plan shall be approved by STUK or a STUK-approved inspection organisation before the manufacturing of a Safety Class 2 electric motor or a non-serial electric motor (serial pumps having a rated output less than 15 kw excluded). Manufacturing means here the manufacturing of a prefabricated or other part that essentially relates to the acceptability of the electric motor s structural or functional dimensioning. The construction plan of a serial electric motor shall be approved by STUK or a STUK-approved inspection organisation before construction inspection if the electric motor s rated output is less than 15 kw or the electric motor belongs to Safety Class 3. A STUK-approved system level design basis for the electric motor is a prerequisite for construction plan approval. 14
15 GUIDe YVL 5.7 / 28 Ap r i l 2008 STUK Table 1. General sharing of pump unit inspections (STUK and inspection organisation). Safety Class Design Pump specification / pump unit STUK STUK STUK STUK Construction plan / pump STUK STUK IO IO Construction plan / electric motor STUK IO Manufacturing and fabrication Construction inspection / pump STUK STUK IO IO Construction inspection / electric motor STUK IO Installation / pump unit Installation plan STUK STUK IO IO Installation inspection STUK STUK IO IO Commissioning / pump unit *) Commissioning inspection, Phases 1 and 2 STUK STUK STUK STUK Trial run plan STUK STUK STUK STUK Operation / pump unit Plans for repairs and modifications; construction and installation inspection STUK STUK IO IO Commissioning inspection of repairs and modifications STUK STUK STUK*) STUK*) STUK = The Finnish Radiation and Nuclear Safety Authority, IO = inspection organisation *) the commissioning inspection of Safety Class 3 or 4 pumps and electric motors having a rated output less than 100kW is conducted during system commissioning 12.4 Inspections and testing STUK or a STUK-approved inspection organisation performs pump and electric motor inspections and tests (hold and witness points) that are defined in the approved inspection plan or whose preformance is otherwise required. When a type test is required, a type test procedure shall be approved by STUK before the test. A test report of electric motor factory tests shall be submitted to STUK or a STUK-approved inspection organisation for approval. Construction inspections shall be approved by STUK or a STUK-approved inspection organisation before the pump unit is installed Installation The pump unit s installation plan shall be approved by STUK or a STUK-approved inspection organisation before installation is started. The pump unit s installation inspection is performed by STUK or a STUK-approved installation organisation. The installation inspection shall be approved by STUK or a STUK-approved inspection organisation before the pump unit is put into service Commissioning STUK performs a separate two-phase commissioning inspection on the pump unit or carries it out during the system s commissioning as stated earlier in the text. In the separate two-phase inspection the trial run plan shall be approved by STUK before the trial run Phase 1 of the commissioning inspection shall be approved by STUK before Phase 2 Phase 2 of the commissioning inspection shall be approved by STUK before the pump unit is put into service Operation, maintenance and modifications STUK oversees that the instructions and plans used for pump unit operation and maintenance are adequate and that they are complied with. Construction, installation and trial run plans for repairs and modifications shall be approved by STUK or a STUK-approved inspection organisation before entering a corresponding phase of the repair or modification. The construction inspections of repairs or modifications, and of the strategic spare part procured for this purpose, shall be approved by 15
16 STUK GUIDe YVL 5.7 / 28 Ap r i l 2008 STUK or a STUK-approved inspection organisation before installation. The installation inspection of repairs or modifications shall be approved by STUK or a STUK-approved inspection organisation before the pump unit is put into service. The commissioning inspection of repairs or modifications shall be STUK-approved before the pump unit is put into service. 13 References 1. API Standard 610 Centrifugal Pumps for Petroleum, Petrochemical and Natural Gas Industries, Tenth Edition. 2. EN ISO 9905 Technical specifications for centrifugal pumps. Class I. 3. EN ISO 5199 Technical specifications for centrifugal pumps. Class II. 4. ISO 9908 Technical specifications for centrifugal pumps. Class III. 5. EN ISO 9906 Rotodynamic pumps. Hydraulic performance acceptance tests. Grades 1 and 2, 1st Edition ASME Boiler & Pressure Vessel Code, Section III, Division 1, Subsection NB Pump Design ASME Boiler & Pressure Vessel Code, Section III, Division 1, Subsection NC Pump Design. 8. ASME OM CODE-2001 Code for Operation and Maintenance of Nuclear Power Plants, Subsection ISTB In-service Testing of Pumps in Light-Water Reactor Nuclear Power Plants. 9. ASME QME Qualification of Active Mechanical Equipment Used in Nuclear Power Plants. 10. ISO 7919 Mechanical vibration of non-reciprocating machines Measurements on rotating shafts and evaluation criteria, Parts ISO Mechanical vibration Evaluation of machine vibration by measurements on non-rotating parts, Parts ISO Mechanical vibration Balance quality requirements of rigid rotors Part 1: Determination of permissible residual unbalance. 13. ANSI/HI American National Standard for Pump Intake Design. 14. KTA 3504 Elektrische Antriebe des Sicherheitssystems in Kernkraftwerken. 15. IEC Rotating electrical machines, rating and performance. 16. IEC 71-1 Insulation co-ordination, Definitions, principles and rules. 17. IEC 71-2 Insulation co-ordination, Application guide. 18. IEC Electrical insulation, Thermal classification. 16
7.1 General 5 7.2 Events resulting in pressure increase 5
GUIDE YVL 2.4 / 24 Ma r ch 2006 Primary and secondary circuit pressure control at a nuclear power plant 1 Ge n e r a l 3 2 General design requirements 3 3 Pressure regulation 4 4 Overpressure protection
ELECTRICAL AND I&C EQUIPMENT OF A NUCLEAR FACILITY
ELECTRICAL AND I&C EQUIPMENT OF A NUCLEAR FACILITY 1 Introduction 5 2 Scope of application 6 3 Requirement specification, selection, and procurement of electrical and I&C equipment and cables 7 3.1 General
HOISTING AND TRANSFER EQUIPMENT OF A NUCLEAR FACILITY
HOISTING AND TRANSFER EQUIPMENT OF A NUCLEAR FACILITY 1 Introduction 5 2 Scope of application 6 3 Equipment requirement specifications for hoisting device units 7 4 Manufacturer 7 4.1 General 7 4.2 Obligations
NUCLEAR POWER PLANT PRESSURE EQUIPMENT
GUIDE YVL 3.8 / 22 SEPTEMBER 2003 NUCLEAR POWER PLANT PRESSURE EQUIPMENT In-service inspection with non-destructive testing methods 1 GENERAL 5 2 DEFINITIONS 5 3 REQUIREMENTS 7 4 IN-SERVICE INSPECTION
MANAGEMENT SYSTEM FOR A NUCLEAR FACILITY
GUIDE YVL A.3 / 2 June 2014 MANAGEMENT SYSTEM FOR A NUCLEAR FACILITY 1 Introduction 5 2 Scope of application 6 3 Management system 6 3.1 Planning, implementation, maintenance, and improvement of the management
Nuclear power plant systems, structures and components and their safety classification. 1 General 3. 2 Safety classes 3. 3 Classification criteria 3
GUIDE 26 June 2000 YVL 2.1 Nuclear power plant systems, structures and components and their safety classification 1 General 3 2 Safety classes 3 3 Classification criteria 3 4 Assigning systems to safety
PROBABILISTIC RISK ASSESSMENT AND RISK MANAGEMENT OF A NUCLEAR POWER PLANT
PROBABILISTIC RISK ASSESSMENT AND RISK MANAGEMENT OF A NUCLEAR POWER PLANT 1 Introduction 3 2 Scope of application 3 3 Development and use of the PRA 4 3.1 General requirements 4 3.2 PRA during the design
Concrete structures for nuclear facilities
22 May 1992 Concrete structures for nuclear facilities 1 General 3 2 Safety analysis report, classification document and quality assurance programmes 3 3 Design documents for concrete structures 4 3.1
TYPE APPROVAL CERTIFICATION SCHEME MASS PRODUCED DIESEL ENGINES
1. Introduction TYPE APPROVAL CERTIFICATION SCHEME MASS PRODUCED DIESEL ENGINES 1.1 This scheme details the tests and inspection of diesel engines manufactured by mass production system for use in marine
Rules for Classification and Construction Additional Rules and Guidelines
VI Rules for Classification and Construction Additional Rules and Guidelines 5 Pumps 1 Guidelines for the Design, Construction and Testing of Pumps Edition 2007 The following Guidelines come into force
SAFETY DESIGN OF A NUCLEAR POWER PLANT
GUIDE YVL B.1 / 15 November 2013 SAFETY DESIGN OF A NUCLEAR POWER PLANT 1 Introduction 5 2 Scope 5 3 Management of design 5 3.1 Organisations responsible for design 5 3.2 Design processes 6 3.3 Configuration
Safety assessment of the Loviisa nuclear power plant
/ OCTOBER 2007 B Safety assessment of the Loviisa nuclear power plant Statement regarding the licence application by Fortum Power and Heat Oy concerning the operation of the Loviisa nuclear power plant
PUMP VIBRATION STANDARDS GUIDELINES
EUROPEAN ASSOCIATION OF PUMP MANUFACTURERS ASSOCIATION EUROPÉENNE DES CONSTRUCTEURS DE POMPES EUROPÄISCHE VEREINIGUNG DER PUMPENHERSTELLER PUMP VIBRATION STANDARDS GUIDELINES First edition - 15 July 2013
Government Degree on the Safety of Nuclear Power Plants 717/2013
Translation from Finnish. Legally binding only in Finnish and Swedish. Ministry of Employment and the Economy, Finland Government Degree on the Safety of Nuclear Power Plants 717/2013 Chapter 1 Scope and
Nuclear Safety Council Instruction number IS- 23 on in-service inspection at nuclear power plants
Nuclear Safety Council Instruction number IS- 23 on in-service inspection at nuclear power plants Published in the Official State Gazette (BOE) No 283 of November 24 th 2009 Nuclear Safety Council Instruction
Mechanical Installation
Page -1-1. INTRODUCTION AND PURPOSE 1.1. This specification covers the installation, testing and precommissioning of mechanical equipment. Work is to be performed in conjunction with the manufacturer s
ALIGNMENT. Pump and Driver Alignment
ALIGNMENT Pump and Driver Alignment Alignment Subject: Pump and Driver Alignment In the pump business alignment means that the centerline of the pump is aligned with the centerline of the driver. Although
Pump Maintenance - Repair
Pump Maintenance - Repair Brian Trombly Mo Droppers Cummins Bridgeway, Gaylord, Mi The basic centrifugal pump consists of two main elements: 1. The rotating element which includes an impeller and a shaft.
IMPORTANT SAFETY NOTICE
IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds
APPENDIX F VIBRATION TESTING PROCEDURE
APPENDIX F VIBRATION TESTING PROCEDURE Appendix F SPS-F-1 of 14 VIBRATION PERFORMANCE TESTING I. General Perform a vibration analysis on all motor driven equipment listed below after it is installed and
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will
TRANSIENT AND ACCIDENT ANALYSES FOR JUSTIFICATION OF TECHNICAL SOLUTIONS AT NUCLEAR POWER PLANTS
TRANSIENT AND ACCIDENT ANALYSES FOR JUSTIFICATION OF TECHNICAL SOLUTIONS AT NUCLEAR POWER PLANTS 1 GENERAL 3 2 EVENTS TO BE ANALYSED 3 2.1 General requirements 3 2.2 Analyses of plant behaviour 4 2.3 Analyses
USE OF IONIZING RADIATION IN THE TEACHING OF PHYSICS AND CHEMISTRY
GUIDE ST 5.3 / 4 MAY 2007 USE OF IONIZING RADIATION IN THE TEACHING OF PHYSICS AND CHEMISTRY 1 Ge n e r a l 3 2 Safety licences and exemption from licensing 3 3 Safety licence-exempt use of radiation 3
26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
Owner-User Pressure Equipment Integrity Management Requirements
the pressure equipment safety authority Owner-User Pressure Equipment Integrity Management Requirements AB-512 Edition 2, Revision 0 Issued 2015-06-25 Owner-user Pressure Equipment Integrity Management
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business
RADIATION PROTECTION AND EXPOSURE MONITORING OF NUCLEAR FACILITY WORKERS
RADIATION PROTECTION AND EXPOSURE MONITORING OF NUCLEAR FACILITY WORKERS 1 Introduction 5 2 Scope of application 5 3 Occupational radiation protection 6 4 Operation of the radiation protection organisation
CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.
CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc. 1 Centrifugal Pump- Definition Centrifugal Pump can be defined as a mechanical device used to transfer liquid of various types. As
DNVGL-CP-0393 Edition December 2015
CLASS PROGRAMME Type approval DNVGL-CP-0393 Edition December 2015 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
Fire Pump Plan Review March 2010
Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:
AC Electric Motors best practice
If you want to learn more about best practice machinery maintenance, or world class mechanical equipment maintenance and installation practices, follow the link to our Online Store and see the Training
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
OHV / OHVL Type OH3 Vertical Inline Pumps ISO 13709 (API 610)
OHV / OHVL Type OH3 Vertical Inline Pumps ISO 13709 (API 610) The Heart of Your Process OHV / OHVL Type OH3 Vertical Inline Pumps ISO 13709 (API 610) OHV OHVL OHV/OHVL Sales Presentation slide
Aftermarket Technical Service Solutions for Pumping Technologies
Aftermarket Technical Service Solutions for Pumping Technologies HIGH QUALITY OEM PARTS, SERVICE, REPAIR, UPGRADES + RE-RATES: DELIVERING VALUE FOR OUR CUSTOMERS SPX - An Introduction SPX is a Fortune
due to uncertainty. This, in turn, has a direct impact on equipment availability and maintenance costs. Unfortunately, due to misconceptions and
due to uncertainty. This, in turn, has a direct impact on equipment availability and maintenance costs. Unfortunately, due to misconceptions and pressure from plant operators to get "back on line", it
CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ
GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html
Oil & Gas. CHTR Centrifugal, High-pressure, Multistage Barrel Pump to API 610, 10 th Edition.
Oil & Gas CHTR Centrifugal, High-pressure, Multistage Barrel Pump to API 610, 10 th Edition. 2 Introduction CHTR Reliable delivery at high pressure. Day in and day out, KSB pumps prove their worth again
Qualification of In-service Inspections of NPP Primary Circuit Components
Qualification of In-service Inspections of NPP Primary Circuit Components ABSTRACT Matija Vavrouš, Marko Budimir INETEC Institute for nuclear technology Dolenica 28, 10250 Zagreb, Croatia [email protected],
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
HPT High Speed Boiler Feedwater Pumps
HPT High Speed Boiler Feedwater Pumps The Heart of Your Process Types of Boiler Feedwater Pumps Diffuser Casing Segmental Ring Volute Casing Horizontal Split Diffuser Casing High Speed Barrel Casing HPT
TOPIC: 191004 KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?
KNOWLEDGE: K1.01 [3.3/3.5] P21 Which one of the following contains indications of cavitation in an operating centrifugal pump? A. Low flow rate with low discharge pressure. B. Low flow rate with high discharge
جامعة البلقاء التطبيقية
AlBalqa Applied University تا سست عام 997 The curriculum of associate degree in Air Conditioning, Refrigeration and Heating Systems consists of (7 credit hours) as follows: Serial No. Requirements First
Pumps 101: Operation, Maintenance and Monitoring Basics
White Paper Pumps 101: Operation, Maintenance and Monitoring Basics Daniel Kernan Manager Monitoring and Control Group, ITT Executive Summary Pumps are at the heart of most industrial processes, and the
BODY OF KNOWLEDGE API-653 ABOVEGROUND STORAGE TANK INSPECTOR CERTIFICATION EXAMINATION November 2015, March 2016 and July 2016 (Replaces October 2013)
BODY OF KNOWLEDGE API-653 ABOVEGROUND STORAGE TANK INSPECTOR CERTIFICATION EXAMINATION November 2015, March 2016 and July 2016 (Replaces October 2013) API Authorized Aboveground Storage Tank Inspectors
CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html
Hydraulic Troubleshooting PRESENTED BY
Hydraulic Troubleshooting PRESENTED BY NORMAN KRONOWITZ Introduction Welcome to the CMA/Flodyne/Hydradyne s Hydraulic Troubleshooting presentation. We will introduce many aspects of troubleshooting hydraulic
WHAT IS INFRARED (IR) THERMOGRAPHY
WHAT IS INFRARED (IR) THERMOGRAPHY IR Thermography is the technique of producing pictures called from the invisible thermal radiation that objects emit. This is a non-contact means of identifying electrical
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
\ srl High Technology Gear Reducers and Cardan Shafts CERTIFIED QUALITY SYSTEM: UNI ISO EN 9001:2008 ICIM 2779/2; IQNET N. IT-28236 UNIVERSAL SHAFT
UNIVERSAL SHAFT CAT CERTIFICATION CARDAN SHAFTS - COUPLINGS Alongside with the production of special gearboxes, our company has developed the production of Universal shafts, with the same high quality
Unit LT01 Carry Out Routine Lift Truck Maintenance
Unit LT01 Carry Out Routine Lift Truck Maintenance UNIT OVERVIEW This unit is about conducting routine maintenance, adjustment and replacement activities as part of the periodic servicing of Lift Trucks.
OPERATING AND MAINTENANCE INSTRUCTIONS PUMP TYPE 215.10
OPERATING AND MAINTENANCE INSTRUCTIONS PUMP TYPE 215.10 To Pump model Pump number Our order Your order Order date Reference Item number Destination Plant Before storing, installation, operation or maintenance
HORIZONTAL PUMPING SYSTEM
HORIZONTAL PUMPING SYSTEM BORETS U.S. INC. PERFORMANCE TECHNOLOGY INNOVATION Horizontal Pumping System What is HPS? HPS classification, Pumps, Stages, Impellers, Curves/Performance, Components Why use
BOWIE PUMPS OPERATION - MAINTENANCE
BOWIE PUMPS OPERATION - MAINTENANCE PUMPING PRINCIPLE: The meshing owieeof the gears cause a slight depression, with the resulting enmeshing of the gears causing a vacuum drawing the fluid being pumped
Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)
17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure
SECURITY ARRANGEMENTS OF RADIATION SOURCES
SECURITY ARRANGEMENTS OF RADIATION SOURCES 1 General 3 2 The party running the radiation practice shall be responsible for security arrangements 3 3 Places of use and storages of radiation sources shall
Unit 24: Applications of Pneumatics and Hydraulics
Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 1 HYDRAULIC PUMPS The material needed for outcome 2 is very extensive so there
ABSTRACT. The Guidelines Section F is related to the Purchasing requirements of NSQ100 (Chapter 7.4). Summary
Page 1 / 9 ABSTRACT This document is the Section F to NSQ-100 Guidelines. Its objective is to help to the understanding of NSQ-100 requirements through some examples or recommendations and descriptions
Hydraulic control unit series 0086-372-01
Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3
MEMBRANE VACUUM MINI PUMPS
MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free
GMC 2013: Piping Misalignment and Vibration Related Fatigue Failures
GMC 2013: Piping Misalignment and Vibration Related Fatigue Failures www.betamachinery.com Authors/Presenters: Gary Maxwell, General Manager, BETA Machinery Analysis Brian Howes, Chief Engineer, BETA Machinery
On-Site Risk Management Audit Checklist for Program Level 3 Process
On-Site Risk Management Audit Checklist for Program Level 3 Process Auditor name: Date: I. Facility Information: Facility name: Facility location: County: Contact name: RMP Facility I.D. Phone Number:
Vertical selfpriming Side-Channel Pumps Type WPV
Vertical selfpriming Side-Channel Pumps Type WPV FIELD OF APPLICATION The side-channel pumps are selfpriming and operate more economically (better efficiency) than normal centrifugal pumps when handling
Jet Propulsion System
This repair manual is valid for the following jet pump variants: 0333_ 0 V3 007 3. 033_ 0 V 007 3. 0380_ 3 V 007 3. 0335_ 3 V 007 3. 033_ 66 V 008. 0338_ 66 V 008. Table of Contents Before you begin working
Ergo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
HIGH TEMPERATURE TWIN SCREW PUMPS. By: David B. Parker Two Screw Product Engineer IMO Pump Warren Warren, Massachusetts
HIGH TEMPERATURE TWIN SCREW PUMPS By: David B. Parker Two Screw Product Engineer IMO Pump Warren Warren, Massachusetts David B. Parker is the Two Screw Product Engineer for IMO Pump - Warren, in Warren,
Supporting New Build and Nuclear Manufacturing in South Africa
ASME Nuclear Codes and Standards Supporting New Build and Nuclear Manufacturing in South Africa Sandton, South Africa, October 7-8, 2008 Session 3 Section III - Component Design and Construction Ralph
Fuel Treatment and Conditioning Systems
RULES FOR CLASSIFICATION OF Ships PART 6 CHAPTER 14 NEWBUILDINGS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS Fuel Treatment and Conditioning Systems JULY 2006 This chapter has been amended since the
Vertical Pumps for the Oil & Gas Industry
Vertical Pumps for the Oil & Gas Industry ITT API Expert ITT Commitment ITT is committed to the Oil and Gas market, which is the largest segment of our business. We have been investing in technology to
Pressure Equipment Certification. Ensure the Conformity and Quality of Your Pressure Equipment. Worldwide. www.tuv.com/asme
INDUSTRIAL SERVICES PRESSURE EQUIPMENT CERTIFICATION Pressure Equipment Certification. Ensure the Conformity and Quality of Your Pressure Equipment. Worldwide. www.tuv.com/asme Worldwide Compliance of
KS Vertical In-Line Pump
KS Vertical In-Line Pump 302-032 Installation, Operation & Maintenance Manual SUPERSEDES: July 1, 2010 EFFECTIVE: August 1, 2012 Plant ID No. 001-1014 SAFETY REQUIREMENTS 1. IMPORTANT! These instructions
Course available 24/7 for up to six months from the date of purchase or until completion
SPED ONLINE COURSE TRAINING Piper BootCamp and Process Plant Layout BOTH Piper BootCamp and Process Plant Layout online courses contain: Approximately 25 hours of online videos Printable notes Links to
Fixed displacement vane pumps
Fixed displacement vane pumps RE 1335/1.5 Replaces: 11.2 1/22 Types PVV and PVQ Nominal sizes 18 to 193 Series 1X Maximum operating pressure 21 bar Maximum displacement 18 to 193 cm 3 Doppelpumpe_d_ Double
Pumps for Pipelines and Transportation
Engineering Flow Solutions Pumps for Pipelines and Transportation API 610 / ISO 13709:9 Midstream The main volume of the oil transit accounts for the pipeline transport. Around 97% of produced oil is
Fire Sprinkler System Maintenance and Testing Page 1 MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS
Page 1 MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS Introduction When properly installed and maintained, automatic fire sprinkler systems have proven to be the most effective means for protecting
Quality Assurance QUALITY ASSURANCE PLAN
Revision 2 Page 1 of 40 QUALITY ASSURANCE PLAN PLAN APPROVALS: Jeff Shouse Signature on File DIRECTOR OF QUALITY ASSURANCE DIRECTOR OF QUALITY ASSURANCE (signature) DATE Rodney Baltzer Signature on File
Testing Capabilities. Worldwide Designers & Manufacturers of Air Moving Equipment
Testing Capabilities Twin Twin City City Fan Fan Companies, Companies, Ltd. Ltd. Worldwide Designers & Manufacturers of Air Moving Equipment TestingCapabilities Twin City Fan Companies, Ltd. In today s
Boiler Feed Pumps in Utility Power Stations. Generate Power Reliably and Economically
Boiler Feed Pumps in Utility Power Stations Generate Power Reliably and Economically We will make sure 2 KSB Your Pump and Valve Specialist Worldwide you achieve the maximum yield Through targeted investments
COMMISSIONING OF HVAC SYSTEMS
FORM CL-01 SYSTEMS / EQUIPMENT INCLUDED : SYSTEM STARTUP CHECKLIST I - PRE - STARTUP INSPECTION EQUIPMENT MOUNTING & SETTING CONTROL, INTERLOCK & POWER WIRING ALIGNMENT OF MOTORS & DRIVES PIPING, CONNECTIONS
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
BSM MOTOR DRIVEN CENTRIFUGAL PUMPS
PRINCIPLE OF OPERATION A hydraulically and dynamically balanced impeller with raised vane sections discharges liquid as a result of the centrifugal force developed in rotation. The head developed is entirely
How To Clean Up A Reactor Water Cleanup
General Electric Systems Technology Manual Chapter 2.8 Reactor Water Cleanup System TABLE OF CONTENTS 2.8 REACTOR CLEANUP SYSTEM... 1 2.8.1 Introduction... 2 2.8.2 System Description... 2 2.8.3 Component
Structural Integrity and NDE Reliability II
Structural Integrity and NDE Reliability II Preparing for EPR TM Reactor Vessel Inspection J. Laube, AREVA NDE Solutions / intelligendt, Germany Y. Bouveret, AREVA NDE Solutions / Intercontrole, France
Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP
Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, 11500 HP ABB The Preferred Partner Egypt Cement Corporation, a major cement manufacturer, has chosen ABB wound rotor motors for all key applications
Mobile field balancing reduces vibrations in energy and power plants. Published in VGB PowerTech 07/2012
Mobile field balancing reduces vibrations in energy and power plants Published in VGB PowerTech 07/2012 Dr. Edwin Becker PRÜFTECHNIK Condition Monitoring PRÜFTECHNIK Condition Monitoring GmbH 85737 Ismaning
Max. Head (m) LVR3-7-220V 3 32 5 44 0,55 10 50Hz ~ 220 V Oval Flange G1. LVR3-7-380V 3 32 5 44 0,55 10 50Hz ~ 380 V Oval Flange G1
Description NordicFlow s keep the system pressurized during normal conditions and prevent unnecessary activation of the main pump. They have compact design, high efficiency, low noise, reliable sealing
VERTICAL TURBINE AND PROPELLER PUMPS
VERTICAL TURBINE AND PROPELLER PUMPS INTRODUCTION Vertical Turbine and Propeller Pumps Model 7000 Series Turbine Pump Model 800 Series Axial Flow Propeller Pump Model 800 Series Mixed Flow Propeller Pump
H i g H E n E r gy, M u lti-stag E, D i ffu s E r type, Bar r E l Cas E, B Oi le r fe E D pu M p
CUP-FK High Energy, Multi-stage, Diffuser Type, BARREL CASE, BOILER FEED PUMP SPX - An introduction SPX is a Fortune 500 multi-industry manufacturing leader, headquartered in Charlotte, North Carolina.
Improving regulatory practices through the OECD-NEA Stress Corrosion Cracking and Cable Ageing Project (SCAP)
Improving regulatory practices through the OECD-NEA Stress Corrosion Cracking and Cable Ageing Project (SCAP) A. Yamamoto a, A. Huerta a, K. Gott b, T. Koshy c a Nuclear Safety Division, OECD Nuclear Energy
Highly flexible couplings
Construction and operation 8.03.00 Instructions for installation 8.03.00 Types of stress 8.04.00 Diagrams for static deformation of the coupling ring 8.05.00 Coupling size 8.07.00 Examples of combinations
Maintenance and Service Instruction
Screw pumps E4 Maintenance and Service Instruction E4 1 IMO AB This instruction is valid for all E4 pump models shown on page 2 Contents Page List of components 2 Exploded view/ordering code 3 Service
RADIOACTIVE WASTE MANAGEMENT AND DECOMMISSIONING IN FINLAND
RADIOACTIVE WASTE MANAGEMENT AND DECOMMISSIONING IN FINLAND 1. NATIONAL FRAMEWORK FOR MANAGEMENT AND REGULATION OF RADIOACTIVE WASTE AND DECOMMISSIONING 1.1 National framework 1.1.1 Overview of national
The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,
The Company QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design, manufacturing and service needs in the field of submersible pumps. Our engineering
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
The Piping System Model a New Life Cycle Document. Elements of the Piping System Model
Piping System Model as a Life Cycle Document White Paper Introduction When designing piping systems, a variety of documents are created providing the details necessary to design, purchase, build, and test
Pump Selection and Sizing (ENGINEERING DESIGN GUIDELINE)
Guidelines for Processing Plant Page : 1 of 51 Rev 01 Feb 2007 Rev 02 Feb 2009 Rev 03 KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru. (ENGINEERING DESIGN GUIDELINE)
Pump and Valve Components and Maintenance
Pump and Valve Components and Maintenance Outline: 1. Split case and End Suction pumps, industry in the 21 st century, cost of ownership, and performance tips 2. Split case Pumps features, maintenance,
The State Fire Marshal's Office and the VDH/Office of Licensure and Certification. Generator Testing in Nursing Facilities
Generator Testing in Nursing Facilities Introduction Recent emergencies and natural disasters have emphasized the need to ensure that nursing facilities have an adequate EPSS in place should the loss of
SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
