USE & CARE MANUAL WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR
|
|
|
- Augustus Cook
- 9 years ago
- Views:
Transcription
1 BTH Electric Boilers Models ranging from 8 kw to 36 kw : 240 Volts ( 1 phase ) & 600 Volts ( 3 phases ). USE & CARE MANUAL WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR Your BTH Electric Boiler has been carefully assembled and factory tested to provide years of trouble-free service. The following information and safety measures are provided to enable proper installation, operation, and maintenance of this product. It is imperative that all persons who are expected to install, operate or adjust this boiler should read these instructions carefully. Any questions regarding the operation, maintenance, service or warranty of this electric boiler should be directed to the supplier. When all installation steps have been completed, insert this installation manual in its original envelope, and keep in a safe place (close to the boiler) for future reference. THERMO 2000 INCORPORATED revision: Oct Printed in Canada
2 Ratings & Specifications Electric Ratings for 240 VAC /1 ph* (3 wire copper conductors) Model No. Electric Elements (in Watts) at 240V Total at 240V* Suggested Wires 90C* Suggest. Breakers* A B C D Watts Amp. BTU CU Amp. BTH BTH BTH BTH BTH BTH BTH BTH 27 3 x x BTH 30 3 x x BTH 33 3 x x * Boilers could be operated at 208Vac/1ph. The resulting capacity will be 75% of the nominal capacity at 240V and the amperage at 87%. * The wire size and breaker may be different upon specific installation (local electrical codes have priority ). Electric Ratings for 600 VAC / 3 ph (3 wire copper conductors) : Model Electric Elements Electric Elements Total Suggeste d wire 90C Suggested breaker No. Quantity Watts Quantity Watts kw Amp. BTU RW-90 HRC D BTH A BTH A BTH A BTH A BTH A BTH A BTH A * The wire size and breaker may be different upon specific installation (Local electrical codes have priority). Connections sizes & overall dimensions Connections sizes Boiler overall dimensions Boiler return 1 NPT M Height 12 inches Boiler feed 1 NPT M Depth 12 inches Waterworks 1/2 NPT F Width 30 inches Safety valve 3/4 NPT F Shipping weight 99 lbs. Drain valve 1/2 NPT F Operating temperature : from 50 F to 190 F. Maximum operating pressure: 30 p.s.i. BTH Electric Boilers USE & CARE MANUAL (Revision Oct. 2015), Page 2.
3 Unit description: Legend : A. Boiler Water Supply Connection ( 1 inch diameter, NPT male) B. Boiler Water Return Connection ( 1 inch diameter, NPT male) C. Safety Relief Valve ( ¾ inch NPT female ) D. Temperature & Pressure Gage (1/2 inch NPT female ) E. Drain Valve (1/2 inch NPT female ) F. Fill Water Connection (1/2 inch NPT female ) G. Electric Line Knock-Out ( 1 inch ) H. Pilot Light I. Boiler Wall Hanging Brackets J. Electrical Compartment (left or right depending on the location of the hanging bracket on the boiler) BTH Electric Boilers USE & CARE MANUAL (Revision Oct. 2015), Page 3.
4 ! General Safety Precautions Be sure to read and understand the entire Use & Care Manual before attempting to install or to operate this water heater. Pay particular attention to the following General Safety Precautions. Failure to follow these warnings could cause property damage, bodily injury or death. Should you have any problems understanding the instructions in this manual, STOP, and get help from a qualified installer or technician. Introduction! These important safeguards and instruction appearing in this manual are not meant to cover all possible conditions and situations that may occur. It should be understood that common sense, caution and care are factors which cannot be built into every product. These factors must be supplied by the person(s) caring for and operating the unit. LOCAL INSTALLATION REGULATIONS This electric boiler must be installed in accordance with these instructions and in conformity with local codes, or in the absence of local codes, with the National Plumbing Code and the National Electric Code, current edition. In any case where instructions in this manual differ from local or national codes, the local or national codes take precedence. SECURITY CONSIDERATIONS Domestic and commercial installations have a maximum design operating pressure limited to 30 psi by a safety relief valve. Boiler maximum operating temperature is 190 F by design. This boiler is designed to be used only in a hot water heating system.! WARNING CAUTION The heat transfer medium must be water or other non-toxic fluid having a toxicity rating or class of 1, as listed in clinical Toxicology of Commercial products, 5 th edition. Concentration of propylene-glycol shall be limited to 50% LOCATION The electric boiler should be installed in a clean, dry location. Long hot water lines should be insulated to conserve water and energy. The electric boiler and water lines should be protected from exposure to freezing temperature. The electric boiler must be installed horizontally directly on the wall. Use the hanging brackets for leveling the unit The electric boiler must be located or protected so as not to be subject to physical damage, for example, by moving vehicles, area flooding, etc. All models can be installed on combustible floors and in alcoves. Ambient temperature must not exceed 90 F. CLEARANCE For adequate inspection and servicing the following minimum clearance is necessary: Right side Left side Top & Bottom of the boiler Front side of the boiler Back side of the boiler 2 inches 14 inches 6 inches 2 inches 1 inch! CAUTION The electric boiler should not be located in an area where leakage of the tank or water connections will result in damage to the adjacent area or to lower floors of the structure. When such areas cannot be avoided, a suitable drain pan or nonflammable catch pan, adequately drained, and must be installed under the boiler. The pan must be connected to a drain. NOTE: Auxiliary catch pan MUST conform to local codes. BTH Electric Boilers USE & CARE MANUAL (Revision Oct. 2015), Page 4.
5 CORROSIVE ATMOSPHERE The electric boiler should not be located near an air vent blowing a corrosive atmosphere or high humidity. The limited warranty is void when the failure of the electric boiler is due to a corrosive atmosphere. CHECK LIST Please check the identification tag on the unit to make sure you have the right model. List of components shipped with the unit : Pressure relief valve set at 30 PSI. Drain valve. Tridicator (temperature & pressure gage). SHIPMENT INSPECTION Inspect the electric boiler for possible shipping damage. The manufacturer s responsibility ceases upon delivery of goods to the carrier in good condition. Consignee must file any claims for damage, shortage in shipments, or nondelivery immediately against carrier. BTH Electric Boilers USE & CARE MANUAL (Revision Oct. 2015), Page 5.
6 Installation! WARNING The manufacturer s warranty does not cover any damage or defect caused by installation, or attachment, or use of any special attachment other than those authorized by the manufacturer into, onto, or in conjunction with the water heater. The use of such unauthorized devices may shorten the life of the boiler may endanger life and property. The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such unauthorized devices WIRING Wiring must conform to the National Electrical Code and to state or local code requirements. The electric boiler must be electrically grounded in accordance with local codes, or, in the absence of local codes, with the National Electrical Code. 120/240Vac models Wiring must be from a 240 Volt (single phase, 60 Hz) circuit protected by a properly sized breaker. Wire gage (3 wires+ground) must be properly sized. Consult the boiler rating plate to select the proper breaker and wire gage. 600Vac models Line wiring must be from a 600 Volt ( 3 phase, 60 Hz) circuit protected by a properly sized breaker. Wire gage (3 wires+ ground) must be properly sized. Consult the boiler rating plate to select the proper breaker and wire gage. Circulator zoning wiring Components must be wired to ensure that only the circulator corresponding to the zone calling for heat is actuated. Zone valve zoning wiring Connect the low voltage thermostat to the zone valve. Components must be wired to ensure that only the zone valve corresponding to the zone calling for heat is actuated and that the circulator is powered on a demand from any zone. The transformer used to power the zone valves must be sized for the load represented by all zone valves in the heating system. BOILER WATER CONNECTIONS This electric boiler may be connected individually or in parallel with other boilers. If two or more boilers are connected, the reverse-return piping method (whereby the boiler with the first return inlet also has the last supply outlet and so forth until the last return inlet corresponds to the first supply outlet) should be used to connect the boilers in parallel, to ensure an equal water flow rate through each boiler. The boiler water supply, located on the top side, and the boiler water return, located on the bottom side of the boiler are steel pipes (male NPT threaded connection) where supply and return line connections are to be made. Installing a union is recommended on the boiler water supply and return lines to facilitate boiler disconnection for servicing. Dielectric unions are required for protection of the boiler and piping if dissimilar pipe material such as galvanized steel and copper are present. Use only clean, new piping for boiler water lines. Local codes or regulations shall govern the exact type of material to be used. Insulate all pipes containing hot water, especially in unheated areas. Install shutoff (ball) valves for servicing convenience. Thermometer(s) should be installed on the boiler water supply and return lines. Cap or plug unused connections on the boiler. Do not cap the pressure relief valve on the boiler since it will damage and shorten the life of the boiler and may endanger life and property. Flow check valve If the heating system includes a single pump, then to minimize flow by gravity and heat loss during non-draw periods, a flow check valve must be installed. Pressure relief valve An automatic pressure relief valve must be installed during boiler setup. The pressure rating of the relief valve must not exceed 30 psi. The safety relief valve must meet the requirements of BTH Electric Boilers USE & CARE MANUAL (Revision Oct. 2015), Page 6.
7 the ASME Boiler and Pressure Vessel Code and limit the maximum operating boiler pressure. It is a safety device, not an operating control. The BTU per hour rating of the relief valve must equal or exceed the BTU per hour input of the boiler(s) or heat source(s) as marked on the boiler(s) rating plate. Connect the outlet of the relief valve to a discharge line with its lower tip at most 6 above a floor drain, well clear of any live electrical parts. The discharge line must pitch downward from the valve to allow complete draining by gravity of the relief valve and discharge line, and be of a diameter no smaller than that of the valve outlet. The tip of the discharge line should not be threaded or concealed and should be protected from freezing. No valve of any type, restriction or reducer coupling should be installed on the discharge line. Local codes shall govern the installation of relief valves. SYSTEM PRESSURE CONTROL Expansion tank Pressure control devices within the system ensure that each component operates within minimum and maximum allowable pressures and maintain minimum pressure for all normal operating temperatures. They also allow air bleeding, prevent cavitation at the pump inlet and prevent water from boiling within the system; all this is accomplished with minimal addition of new water. The increase in boiler water volume resulting from higher temperature is stored in the expansion tank during periods of high operating temperature and is returned to the system when the temperature decreases. The expansion tank must be able to store the required volume of boiler water during maximum design operating temperature without exceeding the maximum allowable operating pressure, and to maintain the required minimum pressure when the system is cold. Contact your installing contractor, plumbing supply house, or local plumbing inspector for assistance. The point where the expansion tank is connected should be carefully selected to avoid the possibility that normal operation of automatic check or manual valves will isolate the tank from a hot boiler or any part of the system. Pre-charged diaphragm expansion tanks are preferable to air control. These tanks incorporate a balloon-like bladder or diaphragm. It is inflated, prior to filling the system, to a pressure equal to the setting of the water pressure makeup regulator. The expansion tank should be located on the suction or intake side of the pump. The pump can be located either just upstream or just downstream from the boiler. Water pressure makeup regulator Make-up systems must be employed as required by codes. An automatic fill valve must be used with a backflow preventer as required, to maintain minimum system pressure by supplying water to make up for leakage. Air bleeder Oxygen should be excluded from the system to prevent corrosion. As mentioned in the expansion tank paragraph above, this precludes the use of air in direct contact with the boiler water as a pressurization means. Installation of manual or automatic air vent devices prevents air from accumulating in the system. Air vents should be installed at all high points to remove trapped air during initial setup and to ensure that the system is tight. Regularly purge the air out of the system while taking care to avoid personal injuries or property damage caused by hot boiler water spray. Circulator zoning recommendations The preferred location of the circulator pump for each zone is on the boiler supply side, with the expansion tank between the boiler and the pump. A flow check valve must be installed in each zone, preferably on the outlet side of each circulator pump, to prevent water flow to other zones where no heat is required. Zone valve zoning recommendations The preferred location of the circulator pump is on the boiler supply side, with the expansion tank between the boiler and the circulator. Use zone valves with low pressure drop. BTH Electric Boilers USE & CARE MANUAL (Revision Oct. 2015), Page 7.
8 Dual energy installation In order to obtain a special rate from your electric utility for residential use, your BTH boiler can be hooked-up to an existing oil heater. Contact your electric utility to find out if your property is eligible for such rates and how to register for them. The CBE-EM dual-energy control (an available option, three-way, motorized valve (1 NPT F standard) included) is specially designed to electric utility standards. The CBE-EM control selects the least expensive energy source based on outside temperature, user choice or a signal from your utility. A three-way, motorized valve (1 NPT F standard) will direct the water flow either to the oil-fired heater or to your BTH electric boiler, depending on the signal received. This way, your oil heater will cool down and eliminate any energy loss, either through the chimney or by way of conduction in the boiler room. The CBE-EM dual-energy control will start up the oil burner upon receiving the appropriate signal and if the thermostat in the house is calling for heat. It will shut off when the temperature in the boiler reaches its target or when the thermostat in the house is not calling for heat. BTH Electric Boilers USE & CARE MANUAL (Revision Oct. 2015), Page 8.
9 ELECTRIC BOILER WIRING DIAGRAM BTH Electric Boilers USE & CARE MANUAL (Revision Oct. 2015), Page 9.
10 BTH Electric Boilers USE & CARE MANUAL (Revision Oct. 2015), Page 10.
11 BTH Electric Boilers USE & CARE MANUAL (Revision Oct. 2015), Page 11.
12 L1 Diagramme électrique/ Wiring diagram Contrôle Bi-énergy avec chaudière BTH-BE ou DTH-BE Dual control energy CBE-EM with BTH-BE or DTH-BE boiler 120 Vac N Transfo 24 Vac Lumière haut tarif/ High tarif light H H V2 Sonde extérieur/ Outdoor sensor Bi-energie/ Dual energy Electrique/ Electric V3 E2 E1 E2 Relais BTH, DTH/ BTH, DTH Relay V2 Interrupteur DPDT Switch ON-OFF-ON Mazout/ Oil DPST Relais/ Relay T2 T1 T5 T6 T T T T Relais chaudière mazout/ Oil boiler Relay Relais Pompe Externe/ External Pump Relay T3 Thermostat 24V T4 Electrique/ Electric V1 Cablage en usine/ Factory wiring Cablage par l'installateur Wiring by others Noir/ Black Brun/ Brown Bleu/ Blue B A AB Mazout/ Oil Valve 3 voies optionnelle/ Optional 3-way valve 120 Vac Transfo 24 Vac DPST Relais/ Relay Interrupteur DPDT Switch ON-OFF-ON Bi-energie/ Dual energy Electrique/ Electric Mazout/ Oil T1 T2 T3 T4 T5 T6 H H V1 V2 V3 E1 E2 Lumière haut tarif/ High tarif light Chaudière mazout Oil boiler ("T T" relais de combustion/ oil boiler burner) Relais de pompe externe/ External pump relay Thermostat 24V Brun/ Brown Bleu/ Blue Noir/ Black Chaudière électrique BTH, DTH Electric boiler BTH, DTH ("E2 V2" bornier 24 Vac/ terminal E2-V2) Sonde extérieure/ Outdoor sensor Valve 3 voies optionnelle/ Optional 3-way valve BTH Electric Boilers USE & CARE MANUAL (Revision Oct. 2015), Page 12.
13 Basic Piping Schematics SYSTEM PIPING LAYOUT:/ SCHEMA D'INSTALLATION GÉNÉRAL: VALVE ZONING TO BASEBOARDS/ ZONAGE DE PLINTHES PAR ROBINETS MOTORISÉS B T H 6 8 LEGEND/ LÉGENDE : 7 1- MAIN WATER SUPPLY/ ALIMENTATION D'EAU 2-MAINTENANCE VALVE/ VALVE D'ENTRETIEN 3-CHECK VALVE/ CLAPET ANTI-RETOUR 4-PRESSURE REDUCER/ RÉDUCTEUR DE PRESSION 5-EXPANSION TANK/ RÉSERVOIR DE DILATATION 6-CIRCULATING PUMP/ POMPE CIRCULATRICE 7-PURGE VALVE/ ROBINET D'ÉLIMINATION D'AIR 8-DRAIN VALVE/ VALVE DRAINAGE 9-SAFETY VALVE/ SOUPAPE DE SÛRETÉ 10-TEMPERATURE AND PRESSURE GAUGE/ THERMOMANOMÈTRE 11-AUTOMATIC AIR VENT/ PURGEUR D'AIR 12-FLOW CHECK VALVE (REQUIRED ON SYSTEMS WITHOUT MOTORIZED ZONE VALVES)/ CLAPET ANTI-GRAVITÉ (REQUIS SUR SYSTÈME N'AYANT PAS DE ROBINETS MOTORISÉS) 13-MOTORIZED ZONE VALVE/ ROBINETS MOTORISÉS 14-HOT WATER BASEBOARD/ PLINTHES CHAUFFAGES Requirements: 1. The installation must conform to local, state, provincial, national codes. In any case where instructions conflict with the above, let those codes take precedence. 2. This is a basic piping schematic. Please consult the installation manual. 3. Install a pressure relief valve (safety relief valve) on the boiler. 4. Pipe all the safety relief valves and drain valves to the drain or according to the code BTH Electric Boilers USE & CARE MANUAL (Revision Oct. 2015), Page 13.
14 SYSTEM PIPING LAYOUT:/ SCHÉMA D'INSTALLATION GÉNÉRAL DIRECT BOILER WATER SUPPLY TO RADIANT HEATING LOOP/ PLANCHER CHAUFFANT DIRECT TYP.: 105 F 11 B T H TYP.: 90 F 7 LEGEND/ LÉGENDE : 1- MAIN WATER SUPPLY/ ALIMENTATION D'EAU 2-MAINTENANCE VALVE/ VALVE D'ENTRTIEN 3-CHECK VALVE/ CLAPET ANTI-RETOUR 4-PRESSURE REDUCER/ RÉDUCTEUR DE PRESSION 5-EXPANSION TANK/ RÉSERVOIR DE DILATATION 6-CIRCULATING PUMP/ POMPE RECIRCULATION 7-PURGE VALVE/ ROBINET D'ÉLIMINATION D'AIR 8-DRAIN VALVE/ VALVE DE DRAINAGE 9-SAFETY VALVE/ SOUPAPE DE SÛRETÉ 10-TEMPERATURE AND PRESSURE GAUGE/ THERMOMANOMÈTRE 11-AUTOMATIC AIR VENT/ PURGEUR D'AIR 12-SUPPLY HEADER/ COLLECTEUR D'ALIMENTATION 13-RETURN HEADER/ COLLECTEUR DE RETOUR 14-RADIANT IN-FLOOR PIPING/ PLANCHER CHAUFFANT Requirements: 1. The installation must conform to local, state, provincial, national codes. In any case where instructions conflict with the above, let those codes take precedence. 2. This is a basic piping schematic. Please consult the installation manual. 3. Install a pressure relief valve (safety relief valve) on the boiler. 4. Pipe all the safety relief valves and drain valves to the drain or according to the code. BTH Electric Boilers USE & CARE MANUAL (Revision Oct. 2015), Page 14.
15 SYSTEM PIPING LAYOUT:/ SCHÉMA D'INSTALLATION GENERAL 5 MODULATING BOILER WATER SUPPLY TO RADIANT HEATING LOOP/ PLANCHER CHAUFFANT MODULANT B T H TYP.:150 F TYP: 85 F LEGEND : 1- MAIN WATER SUPPLY/ ALIMENTATION D'EAU 2-MAINTENANCE VALVE/ VALVE D'ENTRETIEN 3-CHECK VALVE/ CLAPET ANTI-GRAVITÉ 4-PRESSURE REDUCER/ RÉDUCTEUR DE PRESSION 5-EXPANSION TANK/ RÉSERVOIR DE DILATATION 6-CIRCULATING PUMP/ POMPE RECIRCULATION 7-PURGE VALVE/ ROBINET D'ÉLIMINATION D'AIR 8-DRAIN VALVE/ VALVE DE DRAINAGE 9-SAFETY VALVE/ SOUPAPE DE SÛRETÉ 10-TEMPERATURE AND PRESSURE GAUGE/ THERMOMANOMÈTRE 11-AUTOMATIC AIR VENT/ PURGEUR D'AIR 12-SUPPLY HEADER/ COLLECTEUR D'ALIMENTATION 13-RETURN HEADER/ COLLECTEUR DE RETOUR 14-RADIANT IN-FLOOR PIPING/ PLANCHER CHAUFFANT 15-INJECTION VALVE (SLOW OPENNING)/ VALVE D'INJECTION 16-CIRCUIT BALANCING VALVE/ VALVE DE BALANCEMENT 17-INDOOR / OUTDOUR CONTROLLER/ CONTRÔLEUR MODULANT INT.-EXT. 18-BOILER WATER SUPPLY TEMP. SENSOR/ SONDE DE TEMPÉRATURE D'EAU 19-EXTERIOR TEMPERATURE SENSOR/ SONDE TEMP. EXT. 20-AMBIANT TEMPERATURE SENSOR/ SONDE TEMP. AMBIANTE Requirements: 1. The installation must conform to local, state, provincial, national codes. In any case where instructions conflict with the above, let those codes take precedence. 2. This is a basic piping schematic. Please consult the installation manual. 3. Install a pressure relief valve (safety relief valve) on the boiler. 4. Pipe all the safety relief valves and drain valves to the drain or according to the code. BTH Electric Boilers USE & CARE MANUAL (Revision Oct. 2015), Page 15.
16 PUMP AND PUMP SIZING Boiler water temperature drop (BWTD) through the heating loop A simplified design method based on a 20 F temperature drop (BWTD) between boiler outlet and inlet is commonly used. Although such a method is widely used and generates satisfactory system performance when applied properly, it does not determine the system operating point. The pipe size is often uneconomically large, and the actual system flow rate is likely to be much higher than intended. Such design methods seldom consider temperature drops higher than 20 F, which results in overdesign. Another method by which the boiler water temperature drop (BWTD) could be calculated is to assume a constant supply boiler water temperature minus the return boiler water temperature. For example a boiler might have a return temperature of 140 F. Assuming a constant supply boiler temperature of 180 F, the BWTD would be 40 F ( = 180 F 140 F). Second example: If the boiler water has a return temperature of 120 F and the boiler supply is at 140 F, then the temperature drop is 20 F (=140 F 120 F). By design the boiler water supply temperature cannot be higher than 190 F. Also, when the boiler surfaces are hot due to previous loads such as domestic hot water generation, the large temperature difference between the boiler and its return water can cause the boiler to become thermally shocked. An experienced designer could work with other values than those proposed by looking into the performance tables and using the guidelines stated above to design a state of the art system. The following chart suggests the temperature drop (BWTD) to be used to calculate the pump flow rate. PROPOSED BOILER WATER TEMPERATURE DROP THROUGH THE HEATING CIRCUIT (BWTD) System type Baseboards Cast Iron Radiators Radiant In-Floor Boiler water Supply temperature 190 F to 140 F 160 F to 130 F 120 F to 75 F Boiler water Return temperature 170 F to 120 F 140 F to 110 F 110 F to 65 F BWTD 20 F to 40 F 20 F to 40 F 10 F to 20 F Pump flow rate calculation The boiler s output rating must correspond to the heating load calculations or be within the sizing guide recommendations. Use the equation below to calculate the pump flow rate. Pump flow rate = Boiler output BWTD 500 Pump flow rate is express in U.S. gallons per minute or GPM. The Boiler output ( in net BTU per hour) is the maximum heat to be transferred through the heating loop to meet the heating demand. BWTD is the boiler water temperature drop through the heating loop. For example, a BTH 24 as an output rated at 81,888 BTU per hour. The system is designed for a temperature drop (TD) of 20 F. Pump flow rate = 81, = 8.2 GPM. BTH Electric Boilers USE & CARE MANUAL (Revision Oct. 2015), Page 16.
17 Pipe sizing criteria Proper selection of pipe size is important to efficient system operation. A large pipe size results in lower friction losses and may allow the selection of smaller, more economical pump. The increased pipe size, however, costs more initially and must be balanced against the cost savings realized be smaller pump. Likewise, small pipe costs less initially but must be balanced against the increased operating cost of pumping water through a system with high friction losses. An economical balance should be reached between pump size, operating costs, and pipe diameter. creates a constant pressure (head) of one (1) psi (pound per square inch). Pressure losses are expressed either in feet of water or in psi. Pump manufacturers usually prefer feet of water units. Pump or circulator selection Performance characteristics of centrifugal pumps are described by pump curves, which plot flow versus head or pressure together with other information such as efficiency and power. Consult the manufacturer s pump curves to select the proper model or ask your pump dealer or your HVAC wholesaler for a recommendation. The ASHRAE fundamentals handbook states the general range of pipe friction loss used for the design of hydraulic systems and upper limits of water velocity in piping. A variety of upper limits of water velocity and/or pressure drop in piping and piping systems are used. One recommendation places a velocity limit of 4 feet per second for 2 inch and smaller diameter pipe, and a pressure drop limit of 4 feet of water per hundred feet for piping over 2 inches. These limitations are imposed either to control the levels of pipe and valve noise, erosion and water hammer pressure or for economic reasons. Please note that in the smaller pipe sizes, this velocity limit permits the use of friction loss rates higher than 4 feet per 100 feet. Fluid velocity should be above 1-1/2 to 2 feet per second in order to carry entrained air along to a high point in the system where it can be purged. It is generally accepted that if proper air control is provided to eliminate air and turbulence in the system, the maximum flow rate can be established by a piping friction loss rate of 4 feet of water per 100 feet. This allows velocities greater than 4 feet per second in pipe sizes 2 inches and larger. As piping ages, friction losses increase. It is recommended that for most commercial design purposes a safety factor of 10 to 15 % be added to the values in the tables. What is a foot of water? A column of water at 60 F, 5 feet tall, creates a constant pressure of 5 feet of water at the bottom of the column. If the water column is 2.31 feet tall, the mass of water BTH Electric Boilers USE & CARE MANUAL (Revision Oct. 2015), Page 17.
18 Operation! SAFETY PRECAUTIONS Before operating this boiler, be sure to read and follow these instructions, as well as the warnings printed in this manual. Failure to do so can result in unsafe operation of the boiler resulting in property damage, bodily injury, or death. Should you have any problems reading, following or difficulty in understanding the instructions in this manual, STOP, and get help from a qualified person. Do not turn on the boiler unless it is filled with water. Do not turn on the boiler if the cold water supply shut-off valve is closed. After the boiler has been plumbed and wired, it is now ready to be set for automatic operation. FILLING THE BOILER Open the shutoff valve (and on a zone valve system, manually open zone valve) on the supply piping from the boiler. Open cold water supply valve (fill or makeup water valve) to boiler. To let the air out of the boiler tank during the fill process open the relief valve on top of the boiler. Leave all shutoff valves open. Return zone valves to automatic operation. Check system for leaks and repair. Purge air from the remaining zones, if necessary. Check boiler pressure gage reading. 15 to 20 psi is normal for most installations. ADJUSTING THE AQUASTATS After the system has been manually purged of air, and all components (valves, vents, controllers) have been set properly, the boiler can be started. Never operate this boiler until this has been done. Each electric element has it own aquastat. Set the temperature on the aquastat using the knob graduated in degrees Celsius and Fahrenheit. Set the temperature on the first aquastat to the highest supply temperature required by the heating system. Set the temperature on the second aquastat from 1 F to 5 F below the setpoint of the first aquastat. Usually 2 F below the setpoint of the first aquastat is adequate. Proceed in a similar manner for the 3 rd, 4 th and any supplementary aquastats, lowering the set point by approximately 2 F each time. The elements will thus be activated (and deactivated) in the number required by the set points and the drop (or rise) in boiler water temperature. On initial start up (on the first day of the heating season) with a cold tank, a considerable amount of time may be required for the tank to reach desired temperature. Check the temperature on the boiler temperature gage. Adjust the boiler aquastats as needed. Note that setting the aquastat to a lower setting will not have an immediate effect. The stored boiler water heat will first have to be consumed. Additional checks of the water temperature should follow completion of a cycle. Further adjustments may be necessary as you use your boiler and space heating system. Note: The maximum setting for the boiler water supply to the heating system is 190 F. Safety and energy conservation are factors to be considered when setting the boiler water temperature by using the aquastats. The most energy efficient operation will result when the temperature setting of each aquastat is the lowest that satisfies the needs consistent with the application. Please refer to the BWTD table for more details. BTH Electric Boilers USE & CARE MANUAL (Revision Oct. 2015), Page 18.
19 PUMP POWER SUPPLY Use a relay (Honeywell #RA-889, RA-89A) or the secondary contact of a zone valve (if the heating system is zoned using 4-wire zone valves). When a thermostat calls for heat, the relay will power either the boiler pump or the zone valve (the zone valve will power the boiler pump upon opening fully). If the heating system is designed to use only a single pump, then to minimize flow by gravity and heat loss during non-draw periods, a flow check must be installed. Diagramme électrique/ Wiring diagram Raccordement de pompe BTH/ Wiring pump for BTH Relais de pompe/pump relay Thermostat Relais/Relay RA89A T T jumper Diagramme électrique/ Wiring diagram Raccordement de zone valves/ Wiring for zoned valves system Thermostat Zone 1 L2 L1 Pompe/Pump 120Vac Thermostat Zone 2 Thermostat Zone Vac Zone valve Zone valve Zone valve Transfo 40Va Transfo (3 zones) 20Va Transfo (2 zones) To/ Vers RA-89A 120 Vac Electrical service Diagramme électrique/ Wiring diagram Raccordement de multiples circulateurs/ Wiring for multiple circulators Thermostat Relais/Relay RA89A Thermostat Relais/Relay RA89A T T T T jumper jumper Circulateur/ circulator Zone 1 Circulateur/ circulator Zone 2 L1 L2 120Vac electrical service BTH Electric Boilers USE & CARE MANUAL (Revision Oct. 2015), Page 19.
20 Maintenance INTRODUCTION Properly maintained, your boiler will provide years of dependable, trouble free service. It is recommended that a regular routine maintenance program be established and followed by the user. Components are subject to eventual failure that requires service. Failure to use the correct procedures or parts in these circumstances may make the unit unsafe or reduce the life of the boiler. The owner should have the following inspection and maintenance procedures performed: At all time an immediate inspection shall be made if: An odor of melted plastic or overheating material is detected If a leak coming from the unit is observed BOILER WATER PIPING: Yearly visual inspection. Check all piping for signs of leakage near joints, unions and shut-off valves. Repair as needed. PRESSURE RELIEF VALVE ON TOP OF BOILER: Bi-annual inspection. AIR ELIMINATION Bi-annual inspection Check the operation of the automatic air eliminators and manually open the manual air vents located on your distribution system to eliminate the air that could be present. ELECTRIC INSPECTION Annually It is recommended that a visual inspection be made on the electrical compartments of the boiler to check the seal of the gasket on the element flange an also check for any overheating signs of the components and wires. Required corrections shall be made as soon as possible. Parts used for replacement shall be the same as the original equipment.! WARNING Make sure that the power on the unit has been turn off before opening the electrical compartments of the boiler. Make sure that the discharged water is directed to a suitable drain or other collection device, and will not spray onto anyone. If the safety valve leaks and the boiler pressure is under 28psi, it must be replaced with the same model or its equivalent. If the pressure is above 28psi ask our heating specialist to determine the cause of the high pressure and have the problem repaired. Do not plug the outlet of this valve if a dripping condition occurs.! WARNING The manufacturer s warranties DO NOT cover tank failure due to improper installation or maintenance. If the pressure relief valve on the heater discharges periodically, this may be due to thermal expansion. Immediately call a qualified service technician to inspect and to remedy as needed. BTH Electric Boilers USE & CARE MANUAL (Revision Oct. 2015), ), Page 20.
21 BTH LIMITED WARRANTY Warranty Coverage for Residential Installation. Thermo 2000 Inc. hereby warrants to the original residential purchaser that the BTH tank installed in a residential setting shall be free of leaks during normal use and service for a period of fifteen (15) years from the date of purchase as long as the original residential purchaser owns the home in which the unit was originally installed. Residential setting shall mean usage in a single-family dwelling in which the consumer resides on a permanent basis. Also, residential setting shall mean use in multiple family dwellings in which one (1) BTH tank is to be use in only one (1) dwelling. In the event that a leak should develop and occur within this limited warranty period due to defective material or workmanship, such leak having been verified by an authorized company representative, Thermo 2000 inc. will repair or replace at our sole option the failed unit with the nearest comparable model at the time of replacement. The original residential purchaser is responsible for all costs associated with the removal and reinstallation, shipping and handling to and from manufacturing plant. The replacement unit will be warranted for the remaining portion of the original Warranty. Warranty Coverage for Commercial Installation. Thermo 2000 Inc. warrants to the original purchaser that the BTH tank installed in a commercial setting for fifteen (15) years. Commercial setting shall mean use in other than residential setting stated above in the residential setting definition. In the event that a leak should develop and occur within this limited warranty period due to defective material or workmanship, such leak having been verified by an authorized company representative, Thermo 2000 inc. will repair or replace at our sole option the failed unit with the nearest comparable model at the time of replacement. The original purchaser is responsible for all costs associated with the removal and reinstallation, shipping and handling to and from Manufacturer. The replacement unit will be warranted for the remaining portion of the original Warranty. Limited two years warranty on all BTH components & parts All other BTH components & parts are warranted for a period of two (2) years against defects due to defective material or workmanship. The original purchaser is responsible for all costs associated with the removal and reinstallation, shipping and handling to and from Manufacturer. The components, repaired or replaced are warranted for the residual period of the initial warranty on the unit. 3. Defects or malfunctions resulting from improper installation, maintenance or repair done carelessly or resulting from consumer damage (improper maintenance, misuse, abuse, accident or alteration); or 4. Installation in which a relief valve (pressure) is not installed or if it is not functioning properly, or when it is not connected to a drain to avoid damage to the property; or 5. Installation in which liquid circulating in the tank does not remain in closed circuit or installation in which piping is leaking; or 6. A polybutylene pipe or radiant panel installation without an oxygen absorption barrier is used; or 7. Installation where the acidity of water is not within the normal Environmental Protection Agency (EPA) (between ph ) guidelines or the domestic water contains abnormal levels of particulate matter or water exceeding 10.5 gpg; or 8. Your home contains any type of water softener system and the unit is not installed and maintained in accordance with the manufacturer specifications; or 9. The BTH unit is being subject to non authorized modifications; or 10. Defects or malfunction resulting of storing or handling done elsewhere than Thermo 2000 s manufacturing plant; or 11. Units on which the serial number is removed or obliterated. Limitations. Thermo 2000 shall not be responsible for any damage, loss, and inconvenience of any nature whatsoever, directly or indirectly, relating to the breakdown or malfunction of the unit. This warranty limits its beneficiary s rights. Nevertheless, the beneficiary may have other rights, which vary from state to state. This warranty replaces any other expressed or implicit warranty and constitutes the sole obligation of Thermo 2000 towards the consumer. The warranty does not cover cost of removal, reinstallation or shipping to repair or replace the unit, nor administration fees incurred by the original consumer purchaser. Thermo 2000 reserves its rights to make changes in the details of design, construction, or material, as shall in its judgment constitute an improvement of former practices. This warranty is valid only for installations made within the territorial limits of Canada and the United States. Warranty service procedure Only authorized BTH dealers are permitted to perform warranty obligations. The owner or its contractor must provide Thermo 2000 s head office or authorized depot with defect unit together with the following information: BTH model and serial number, copy of the original sales receipt and owner s identification certificate. Exclusions. This warranty is void and shall not apply if: 1. Defects or malfunctions resulting from installation, repair, maintenance and/or usage that are not done in conformity with the manufacturer s installation manual; or 2. Defects or malfunctions resulting from installation, maintenance, or repair that are not done in accordance with regulations in force; or THERMO 2OOO INC. 500, 9e Avenue, Richmond (Qc) Canada J0B 2H0 Phone: (819) Fax: (819)
MINI BTH INSTALLATION & OPERATING MANUAL
Electric Boilers MINI BTH Models from 3 kw to 12 kw : 208/240V single phase INSTALLATION & OPERATING MANUAL Your MINI BTH Electric Boiler has been carefully assembled and factory tested to provide years
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS
INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS HEAT-FLO HOT WATER STORAGE / BOOSTER TANKS MODELS 30-ST, 40-ST, 40L-ST, 60-ST, 60L-ST, 80-ST, 115-ST, 80-ST-C, 115-ST-C FOR SINGLE TANK INSTALLATIONS For
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
Ceiling Mount Air Handler Manual
www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty
INDIRECT WATER HEATER. Installation and Operating Instruction Manual
INDIRECT WATER HEATER Installation and Operating Instruction Manual Maximum supply temperature to heat exchanger must not exceed 180 F (82 C). Safety Warning: Indirect water heaters are heat-producing
Electric Water Heater
Electric Water Heater Operation and Installation Manual (LIMITED WARRANTY AND TANK REPLACEMENT POLICY) The following information should be noted at time of installation and retained for future reference.
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical appliance, basic safety precautions
Installation Manual DIAPHRAGM WELL TANK
Installation Manual DIAPHRAGM WELL TANK IN-LINE SERIES: 2-5 & 7 GALLON VERTICAL SERIES: 14-20-25-32-36-52-65-86-96-119 GALLON HORIZONTAL SERIES: 7-14 & 20 GALLON NO LEAD NO LEAD: The weighted average of
NAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
INSTALLATION AND SERVICE MANUAL EPJ SERIES INDIRECT WATER HEATERS
INSTALLATION AND SERVICE MANUAL EPJ SERIES INDIRECT WATER HEATERS FOR MODELS EPJ-40 AND EPJ-56 SEE REAR COVER FOR INDEX Read this instruction manual before installation, operation, or service. Failure
THERMOLEC. Installation Instructions for Electric Boilers (CANADA) December 2011 VERSION 11
THERMOLEC Installation Instructions for Electric Boilers (CANADA) December 2011 VERSION 11 Installation Guidelines for Thermolec Electric Boilers Model B 1 Important 1.1 These instructions should be used
Installation Manual DIAPHRAGM WELL TANK
Installation Manual DIAPHRAGM WELL TANK Safety Instructions Installation Warranty IN-LINE SERIES: 2-5 & 7 GALLON HORIZONTAL SERIES: 7-14 & 20 GALLON VERTICAL SERIES: 14-20-32-36-52-86-96-119 GALLON KEEP
2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)
Use & Care Manual With Installation Instructions for the Installer Electric Tankless Water Heaters The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations
CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS
CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS SECTION 1001 GENERAL 1001.1 Scope. This chapter shall govern the installation, alteration and repair of boilers, water heaters and pressure vessels.
Indirect Fired Water Heaters
Indirect Fired Water Heaters Installation and Operating Manual C US Models: SST150-40 SST250-65 SST300-80 SST450-119 CAUTION The heat transfer medium must be water or other nontoxic fluid having a toxicity
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic safety precautions should always
INSTALLATION, OPERATING, AND SERVICE INSTRUCTIONS
INSTALLATION, OPERATING, AND SERVICE INSTRUCTIONS HEAT-FLO HOT WATER STORAGE/ BOOSTER TANKS MODELS 30-ST, 40-ST, 40L-ST, 60-ST, 60L-ST 80-ST, 115-ST, 80-ST-C, 115-ST-C Conforms to UL STD 174 and NSF/ANSI
TANKLESS WATER HEATER INSTALLATION DIAGRAMS
TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water
Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, 1060. Instruction No.
Instruction No. AERCO INTERNATIONAL, Inc., Northvale, New Jersey, 07647 USA PIPING GUIDE GF-115-P Modulex Gas Fired Boiler Systems Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909,
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business
TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
Float and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
Fire Pump Plan Review March 2010
Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:
Techtanium Solar Indirect Water Heater Instruction Manual
To the Installer: Please attach these instructions next to the water heater. To the Consumer: Please read these and all component instructions and keep for future reference. Techtanium Solar Indirect Water
ENGINE COOLING SYSTEM
ENGINE COOLING SYSTEM 1988 Toyota Celica 1987-88 TOYOTA Engine Cooling Systems Celica DESCRIPTION The basic liquid cooling system consists of a radiator, water pump, thermostat, cooling fan, pressure cap,
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
Light Duty Commercial Electric Water Heater
Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and
INSTANT HOT WATER RECIRCULATING SYSTEM
INSTANT HOT WATER RECIRCULATING SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS Save manual for future reference MODEL 500800 Warning Please read carefully before proceeding with installation. Your failure
PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT
PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT GENERAL INFORMATION 1.1 This section applies to piping systems for chilled water, hot water, condenser water, steam, condensate return, fuel oil, refrigerant
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL
Propane Conversion Kit Supersedes: 145.25-IOM2 (708) Form 145.25-IOM2 (908) PROPANE CONVERSION KIT INSTALLATION MANUAL "LPKIT " - PROPANE CONVERSION KIT Kits are available for field conversion from natural
Electric Mini Tank Water Heaters WM-2.5 & WM-4.0
Electric Mini Tank Water Heaters WM-2.5 & WM-4.0 Installation and Operating Instruction Manual Table of Contents Important Safety Instructions 2 Technical Data 3-4 General Information 5 Technical Description
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION
I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL MODELS: HA018240 HA024240 HA027240 HA036240 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic safety
INSTALLATION, OPERATING, AND SERVICE INSTRUCTIONS
INSTALLATION, OPERATING, AND SERVICE INSTRUCTIONS HEAT-FLO INDIRECT-FIRED WATER HEATERS MODELS 30, 40, 40L, 50, 60, 60L, 80, 115 AND 60-HO, 80-HO, 80-HO-C, 115-HO, 115-HO-C 85-XHO, 115-XHO HIGH OUTPUT
Installation and Operating Instruction Manual
Electric Mini Tank Water Heaters CMT-1.3 CMT-2.5 CMT-4.0 CMT-ST70 Tempering valve Optionally available Installation and Operating Instruction Manual Table of Contents Important Safety Instructions 3 General
LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459
SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
OTF Oil Fired Pool Heater
OTF Oil Fired Pool Heater Installation Operation Maintenance Manual Service Policy 722010 Congratulations on the purchase of your new pool heater. In order to maintain peak performance of your pool heater
MODEL 300505 INSTALLATION INSTRUCTIONS
WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 [email protected] Your pump has been carefully packaged at the factory to prevent damage during shipping.
INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)
CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage
Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:
Seaward Products WATER HEATERS OWNER S MANUAL Serial Number: IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, basic safety precautions to reduce the risk of fire, electrical shock,
Miami Heat Pump HP Series Installation Guide
CAUTION- THIS UNIT IS FOR INDOOR USE ONLY!! WARNING BEFORE ANY INSTALLATION OR MAINTANCE IS STARTED PLEASE READ COMPLETE INSTLLATION GUIDE. INSTALLATION START-UP AND SERVICE INSTRUCTION- The HP Water Source
Installation, Maintenance, & Repair Series 4000B/LF4000B
Installation, Maintenance, & Repair Series 4000B/LF4000B Reduced Pressure Zone Assemblies Sizes: 1 2" 2" (15 50mm) RP/IS-A-4000B 4000B/LF4000B Size: 3 /4"! WARNING Testing Read this Manual BEFORE using
MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.
Electric Tankless Water Heater
Electric Tankless Water Heater INSTRUCTION & OPERATION MANUAL TANKLESS WATER HEATERMODELS x AHS5D x AHS21D x AHS7D x AHS24D x AHS9D x AHS27D x AHS11D x AHS14D x AHS16D x AHS18D TECHNICAL ASSISTANCE PLEASE
High kw Electric Tankless Water Heater Troubleshooting Guide
Technical Service Bulletin High kw Electric Tankless Water Heater Troubleshooting Guide Models: WH17, WH27, WH36 AE115, AE125, (FD108 and higher) DANGER: ELECTRIC SHOCK ELECTRICITY IS EXTREMELY DANGEROUS.
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
Water Heaters. Use & Care Manual. Electric Point of Use IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS
Electric Point of Use Water Heaters LISTED 786H IMPORTANT SAFETY INSTRUCTIONS Printed in USA Use & Care Manual With Installation Instructions for the Installer The purpose of this manual is twofold: one,
Ducoterra Radiant Heating Panel Installation Manual
Ducoterra Radiant Heating Panel Installation Manual 1. Introduction Your new radiant heating panels are designed to heat living and working spaces rapidly and efficiently by radiant heating. Like the sun,
Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM
PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM RELIANCE Has Everything Your Customers Need to Do the Job Right! Reliance Water Heater Company was founded in 1981 to provide a water heater
Electric Mini Tank Water Heaters
Electric Mini Tank Water Heaters EMT1 - EMT2.5 - EMT4 - EMT6 Installation and Operating Instruction Manual Table of Contents Important Safety Instructions 2 Technical Data 3-4 General Information 5 Technical
Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)
TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) WARNING - HIGH VOLTAGE AC electrical circuits are connected to this heater. Do not attempt any service work on the
36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION
Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank
Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank This specification describes requirements for a Diesel Fuel Day Tank System consisting of one or more fuel tanks, an Electronic
Indirect Water Heaters
Indirect Water Heaters Installation Start-Up Maintenance Parts Warranty For Residential and Commercial Use WI Models The surfaces of these products contacted by potable (consumable) water contain less
TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER
TWIN EAGLES, INC. Defining the Art of Outdoor Cooking TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER OWNER S MANUAL MODEL TEEH-1512 TEEH-2524 TEEH-3524 NEED ASSISTANCE? PLEASE CALL: (562) 802-3488 This
I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit
I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit IMPORTANT: These installation instructions are meant to be used as a guide for woodstove owners and
DIVERSIFIED HEAT TRANSFER, INC. 1710 Flushing Avenue Ridgewood, NY 11385 Phone: 718-386-6666 / 800-221-1522 Fax: 718-386-7809 www.dhtnet.
Installation & Operating Instructions INDIRECT WATER HEATERS TO THE INSTALLER: This manual is the property of the owner and must be affixed near the water heater for future reference. TO THE OWNER: This
ENERGY RETROFIT PROGRAM
ENERGY RETROFIT PROGRAM An innovative but simple retrofit for existing hot water and chilled water piping systems that will help you save money. REDUCE FLOW BY 50% REDUCE PUMP HEAD BY 75% REDUCE PUMP POWER
RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00
RESIDENTIAL HEATING OIL SERVICE CONTRACT This service contract covers all routine service and maintenance of your residential oil fired furnace or boiler. In addition this contract covers all service calls
What you can expect from your Solar Hot Water System
Owner s Manual Your Solar Hot Water System Thank you for your investment in the FAFCO Solar Hot Water System. Since 1969 our goal has been to design, test, and produce solar heating systems that save you
Standard Hydraulic Piping Flushing Procedure
Page 1 of 6 1.0 Scope This procedure covers the minimum technical requirements for cleaning and flushing of Hydraulic and Piping, and related accessories. 2.0 Introduction In hydraulic fluid power systems,
SL280UHV SERIES GAS FURNACE WARNING
2010 Lennox Industries Inc. Dallas, Texas, USA 506677 01 11/2010 Supersedes 506409 01 SL280UHV SERIES GAS FURNACE Litho U.S.A. FIRE OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could
Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075
Part No. 89047 Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075 Cincinnati, OH 45241-4807 USA ELECTRIC FRYER SAFETY PRECAUTIONS Installation
Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.
Model Number: Serial Number: Information Manual Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters. ATTENTION: IF YOU ARE NOT A LICENSED PLUMBER OR A LICENSED
INSTALLATION INSTRUCTIONS AND HOMEOWNER MANUAL
INSTALLATION INSTRUCTIONS AND HOMEOWNER MANUAL MODELS: AH27, AH24, AH21, AH18, AH16, AH14, & AH 11 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic
Installation & Operation Manual Models: SIT030 - SIT119
SIT-I-O Rev K Installation & Operation Manual Models: SIT030 - SIT119 CAUTION: The heat transfer medium must be water or other nontoxic fluid having a toxicity rating or class of 1, as listed in Clinical
Mini Tank. Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0. Installation and Operating Instruction Manual
Mini Tank Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0 Installation and Operating Instruction Manual Table of Contents Important Safety Instructions 3 General Information 3/6 Technical
Your safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler
WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler Installation Operation Maintenance The WMSLW/WMBLW series is designed for installation in a closet, utility
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
CALIFORNIA PROPOSITION 65 WARNING:
Residential Solar Water Heater USE & CARE MANUAL WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR LISTED 786H The purpose of this manual is twofold: one, for the installing contractor, to provide requirements
Element D Services Plumbing
PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses domestic cold, hot and hot water return distribution systems within and to five feet beyond building perimeter. PART 2 - DESIGN CRITERIA 2.01 GENERAL
Mega-Stor INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS
D E S I G N E D T O L E A D Mega-Stor TM Stainless Steel, Indirect Water Heaters INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL MAINTENANCE PARTS CAUTION 1. having a toxicity rating or Class
MODEL G300 BRAKE BLEEDER
MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY
Boiler & Pressure Vessel Inspection discrepancies and failures
Boiler & Pressure Vessel Inspection discrepancies and failures Water Heaters / Pressure Vessels Pressure Vessels are inspected once every three years. This requires a test of A: safety relief devices B:
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS: INSTALLATION USE & CARE MANUAL IMPORTANT INFORMATION Assembly Instructions 2 Wiring Instructions 2 Outdoor Installation
5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
Ergo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
Arapahoe County Residential Water Heater Installation and Inspection Guide
Arapahoe County Residential Water Heater Installation and Inspection Guide The attached handout is designed to be a general permit submittal and inspection guide covering most installation instances, however
BERMAD Fire Protection
400E-2M/700E-2M IOM Bermad Electrically Controlled Deluge Valve with EasyLock Manual Reset Model: 400E-2M/700E-2M INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 400E-2M/700E-2M Bermad
Solar Skies Stainless Tank Series Water Heater
Solar Skies Stainless Tank Series Water Heater Installation Operation Maintenance Solar Skies Stainless Tank CD1051A.doc Last Revision: 1/31/2011 1 CONTENTS Part 1 Product and Safety Information.....................................
Element D Services Plumbing
Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.
Installation and maintenance instructions
Installation and maintenance instructions Indirect fired domestic hot water tank Logalux ST50/ ST300/ For heating contractors Please read carefully prior to installation and maintenance. 7 747 00 883 09/006
ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.
ITE Indirect calorifier ITE - 400/500/600/750/1000 0310 117 Installation, User and Service Manual Innovation has a name. Read this manual carefully Warning Read this manual carefully before starting the
PLBG/GAS SAFETY Information Bulletin
PLBG/GAS SAFETY Information Bulletin November 2012 P/G-08-02-PLBG/GAS [Rev 3] Page 1 of 11 SUBJECT: REQUIREMENTS FOR COMBINATION HEATING SYSTEMS: DUAL PURPOSE WATER (POTABLE) HEATER (COMBO UNIT) Safety
MUELLER FALLING FILM CHILLERS
MUELLER FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS ARE DESIGNED TO COOL ANY FLUID TO WITHIN 2 F OF ITS FREEZE POINT. The primary application for Mueller s falling film chiller is to cool food-grade
DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES
SECTION 15062 STEAM AND CONDENSATE PIPING PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. Comply with the provisions of the following: 1.2 DESIGN CRITERIA 1. ASME B 31.9 Building Services Piping : for