Energy Efficient Building in Kathmandu Valley A Case Study of Passive and Contemporary Residential Building
|
|
|
- Eustace Cummings
- 9 years ago
- Views:
Transcription
1 Energy Efficient Building in Kathmandu Valley Timila Bajracharya, Shree Raj Shakya, Sushil Bajracharya Department of Mechanical Engineering, IOE, Central Campus, Pulchowk, Tribhuvan University, Nepal Department of Architecture, IOE, Central Campus, Pulchowk, Tribhuvan University, Nepal Corresponding Abstract: In Nepal, energy consumption by residential accounts for 89% of the total national energy consumption [3]. The increasing urbanization and modern lifestyle has further enhanced the energy consumption in the sectors. Building energy efficiency is the first step toward achieving sustainability in s. Energy efficiency helps control rising energy costs, reduce environmental footprints and increase the value and competitiveness of s. It helps to find out the most efficient way to use the energy, identifying the potential savings and also reducing environmental impacts. This research has focused on the measure of energy audit in contemporary residential s of Kathmandu valley. Energy consumption data would provide the initial baseline for the energy use pattern in residences of Nepal, mainly focusing in Kathmandu valley. Furthermore it has also focused on opportunities and challenges of energy reduction methods and technologies for optimum energy use in household sector. The final output will be derived by calculating the total energy saved through improved energy performance of. Keywords: energy efficiency, energy audit, energy consumption. 1. Introduction Energy efficiency has become one of the growing issues all over the world. Energy use in s currently account for about 32% of the global total final energy consumption in the world. In terms of primary energy consumption, s represent around 40% in most countries and 65% of the total electric consumption [1]. In Nepal, the energy consumption by residential s accounts for 89% of the total energy consumption of national consumption [3]. The recent CBS data shows that the number of individual household in Nepal is 54,23,297 with population growth rate of 1.3 per annum and average household size of 4.88 which is an indication for the rise of energy usage in the future in the s sector [2]. The residential sector consumed almost 89% of the total energy consumption of Nepal in 2008/09. Biomass resources are the major fuel used in this sector. Recently renewable sources like biogas and electricity from micro hydro and solar homes systems are substituting conventional fuels used mainly for cooking and lighting [3]. The increasing urbanization and modern lifestyle has further enhanced the energy consumption in the sectors. Besides that, the energy consumption is increased due to the poor thermal construction of the residential s that does not refer climate and does not fulfill the comfort limit of the occupants in the residence. This is a vital sign for the change in our consumption pattern via energy efficient s. Figure 1 Sectoral energy consumption Source: [3] The use of energy efficient s accounts for a large share of the total end use energy. This includes energy used for controlling the climate in s and for the s themselves, but also energy used for appliances, lighting and other installed equipment. Given the long lifespan of most s, the relative energy efficiency of new s will influence energy consumption for many years. Energy efficient improvements can reduce the demand for and costs of cooling and heating systems. Building energy efficiency is the first step toward achieving sustainability in s and organizations. Energy efficiency helps control rising energy costs, 599
2 reduce environmental footprints, and increase the value and competitiveness of s. Sustainability is all about using the resources of today efficiently, in a manner that meets our own needs, but doesn t compromise the ability of others to meet their own needs in the future. 2. Methodology This study is a qualitative research in which data are collected in the field. The research has been carried out step by step. The process of research methodology is divided into three stages. The first stage begins with the literature review aimed to raise the research questions and develops the research. It is followed by preliminary study of energy situation in residential s ending in selection of field study areas. Based on the variable identified, a study starts in the field. The second stage begins with mainly the field study with qualitative surveys of energy use and performance of contemporary residential s. The questionnaires are designed, tested and developed for qualitative surveys for field. This stage contains collection of data, followed by data coding, error checking and tabulation. The third part contains data analysis, followed by testing and triangulation, aiming to draw the final conclusions and recommendation and directions for future research. All the data collected household questionnaire survey from field was analyzed statistically with the help of computer software. The main purpose of research is to discover the energy consumption in contemporary residential s. At the very first, the reference s will be identified and finalized for the data. The reference s studied shall be contemporary two and half storey residential of Kathmandu valley. The family size consists of 4 to 6 family members. Such s are mostly newly built in the valley. So the housing sectors will be chosen for the case study. The planning, material and technology of these s shall be analyzed. The detail of energy use pattern for lighting, cooking, heating and cooling shall be carried out. In this sense, the main research focuses to field study with monitoring energy consumption of different residences per year. It contains evaluation of energy use of s with field data, sample analysis, followed by discussion and aiming to draw the results and conclusions. The qualitative method adopted as household questionnaire survey of energy use by the residents of different s of Kathmandu valley. The objective of qualitative household questionnaire survey is to study the energy scenario of local people in residential. The analysis, discussion and 600 results are further compared and draw the conclusion in this study. 3. Sample Size Calculation The sample size for this research has been determined with the help of sample size calculation software. The population size has been taken from national report The total population size of Kathmandu valley is 25,17,023 that include population of Lalitpur, Bhaktapur and Kathmandu [2]. The confidence level is 95% and confidence interval taken is 9.5%. The sample size determined is 107. Confidence level Confidence Interval Population Size Sample Size Sample Size Calculation 95% 95% 95% 95% 95% 6% 9.75% 7% 9.50% 9.60% Energy Efficiency Measures Energy efficiency in can be attained through three main factors: Reduce heating, cooling demand Utilize renewable energy sources Increase efficiency of heating and cooling equipment Heating and cooling demand in a are influenced by orientation, envelope, thermal mass, natural ventilation and sun shading. Using renewable sources for operational phase of contributes significantly in whole energy efficiency scenario. For instance use of solar thermal for hot water and space heating and cooling. Photovoltaic for electricity and heat pumps. Efficient appliances for heating and lighting increases energy efficiency in s. 5. Case Study 5.1. Investigated Contemporary residential The reference for the study has been divided into two types. The first one is contemporary residential normally built in the valley which Energy Efficient Building in Kathmandu Valley
3 is also a general permissible to built according to bye-law of Kathmandu valley i.e. two and half storey. The reference s are taken from Civil Homes, Phase III, and Binayak Colony. For the study, 38 houses of Civil homes and 35 homes of Binayak Colony were selected. The rest of 34 houses were selected from contemporary houses in Kathmandu valley. The common characteristic of this is that it is built in area of 3 anna to 8 anna, built with RCC structure, bricks and cement mortar for a family size of 4-6 people. Figure 2: Civil Homes, Phase III Figure 3: Binayak Colony Civil homes, Phase III, Sunakothi The is rectangular in shape. The ground floor has living room with dinning space, kitchen and common toilet. The first floor has either two or three bedrooms varying from house area. The second floor has puja room and open terrace. The windows are made of wooden frame with single glazed glass of 6mm. The windows cover nearly 8% of total floor area. The walls are usually 9" thick at the exterior of the house and 5" thick at the inner partition. The walls are built from brick and cement mortar. Sun dried brick are used for both interior and exterior walls. Both exterior and interior walls have cement plaster after brick wall with 2 coats of paints outside. The roofs are flat and has terraces finished with floor tile above the RCC floor Binayak Colony, Bhainsepati The is rectangular in shape. The ground floor has living room with dinning space, kitchen and common toilet. The first floor has either two or three bedrooms varying from house area. The second floor has puja room and open terrace. The windows are made of aluminium frame with single glazed glass of 6mm. The windows cover nearly 8% of total floor area. The walls are usually 9" thick at the exterior of the house and 5" thick at the inner partition. The walls are built from brick and cement mortar. Sun dried brick are used for both interior and exterior walls. Both exterior and interior walls have cement plaster after brick wall with 2 coats of paints outside. The roofs are flat and have been finished with floor tile above the RCC floor Other Contemporary s The s are mostly rectangular in shape. The other features of are similar to houses of Civil homes and Binayak Colony. Table 1: Calculation of U-value of Contemporary Calculation of U-value of Contemporary Building (W/m2K) Brick Wall (230mm thick burnt brick) 1.93 Concrete Roof (110mm ) 2.87 Window (Single Glazed) 5 Energy Consumption per year (kwh/year) Investigated energy efficient residential The study of energy efficient has been limited to the study of Mato Ghar of Buddhanilkantha. Since there are no other passive existing in Kathmandu particularly the residences, the study of energy efficient has to be limited to single case study. The has been taken only as the reference and study of other passive solar techniques in the rather than its direct comparison with contemporary in its energy consumption. Mato Ghar Buddhanilkantha: Figure 4: Mato ghar of Buddhanilkantha Mato Ghar of Buddhanilkantha is single storey residential. It is built in an area of 2000 sq. ft. The main feature of this is it has been designed and constructed with passive solar techniques. Mud is the main component of this and thus has been named as "Mato Ghar". It also has other passive solar technology integrated in Proceedings of IOE Graduate Conference,
4 the like solar photovoltaic panel and solar water heater. It also has floor heating through solar water heating but has not been used yet. Building Form and use: The is rectangular in shape and all the room has been arranged linearly along east west direction. All the living spaces have been placed on the southern side while other utility rooms have been placed towards north. The living room, bed rooms are placed in south and kitchen, toilets, laundry and study room has been placed towards north. The windows are made of double glazed aluminium panel with air cavity. The windows cover nearly 10% of total floor area. The windows provide clear lighting inside the as well as insulate the outer noise to certain amount. The overhangs have been projected from roof so as to provide shade in summer and allow winter sun inside the room. Table 2 Calculation of U-value of Passive Calculation of U-value of Passive Building (W/m2k) Rammed earth (18"thick) 0.37 Double Glazed window 3.06 Insulated roof 0.2 Energy Consumption per year (kwh/year) Data Analysis From the household survey in residential sectors following results have been found Energy use for cooking 42% 51% LPG Electricity Both 7% Figure 5: wall section of Mato Ghar The wall is made of rammed earth. The walls are 18" thick at the exterior and interior partition of the house. The walls are reinforced at different level to resist the seismic forces. The walls are plastered with mud to give smooth texture externally and internally. The south facing walls have big windows to allow sun inside the for lighting and heating while north facing walls have small windows to resist cold wind. It has two way slope roof. The roof has insulation of 2" thick styro foam. the external layer of roof consists of 24 Guage hulas red, under it lies 2"X2" pinewood purlin, radiated aluminium sheet, 2" thick Styro foam insulation, 12 flatten bamboo and bamboo rafters. There is a gap between external layer and purlin which allows the heated air to rise above. Figure 6: Energy use for cooking In residential sector, most of the houses use LPG, i.e. 51% of the household used it for their cooking purpose. The use of electricity has been nominal which is only 7%. While most residences use both electricity and LPG for cooking, which accounts almost 42%. It was found that the use of electricity has been limited to use of rice cooker only. While there is no use of kerosene, wood and briquette found to be used for cooking Energy use for room heating in winter It is found out that 82% consume energy for room heating and only 18% don't use any energy form for room heating in winter. Most of the residence uses LPG heater and electric heater in winter for room heating. 39% use LPG heater and electric heater, 12% use kerosene heater for room heating, 9% uses AC and 1% use firewood. For energy efficiency of, instead of using non renewable energy like LPG heater, kerosene heater, it is better to switch to renewable source of energy like electricity and electric heaters. For more energy efficiency, designing a as passive solar can help to reduce the energy consumption in heating to zero. 602 Energy Efficient Building in Kathmandu Valley
5 18% Energy user- 82% 15% Electric Fan- 85% 82% Non user -18% 85% Air Conditioner- 15% Figure 7: Energy user for room heating in winter Figure 10 Energy use for room cooling in summer 12% 1% 39% 9% 39% Electrical heater- 39% Air conditioner- 9% LPG Heater- 39% Kerosene Heater- 12% Firewood-1% 6.4. Energy use for water heating for shower About 72% use Solar water heater for water heating for shower, 20% use gas gyser, and 4% use electric coil and 4% use other measures such as boiling through LPG and use of water without heating. The percentage use of solar water heater has been high in this figure is because Binayak Colony has solar water heater installed in every house. The solar water heater is one of the renewable energy source measures for saving energy for water heating. 4% 4% Electric coil- 4% Figure 8: Energy use for room heating in winter 6.3. Energy use for room cooling in summer For room cooling in summer, about 59% consumed energy for room cooling and 41% use natural ventilation. Most of the residences use an electric fan. 85% uses electric fan for room cooling and 15% use AC. The energy efficiency can be gained through less use of electric fan for room cooling and using existing natural ventilation in. For this, has to be designed according to wind direction in such a way that maximum natural ventilation passes through the and consumes less energy for cooling. 41% 59% Energy user- 59% Non user - 41% Figure 9: Energy use for cooling in summer 72% 20% Figure 11: Energy use for water heating for shower 6.5. Electricity use for water pump Most of the residences uses pump less than 3 hours/week for water pumping. On the survey, it was found that in Binayak colony water is allowed to flow in residences through gravity flow and thus the people don't have to use pump. No need hours/week 8-12 hours/week 5-8 hours/week 3-5 hours/week ess than 3 hours/week 2% 5% Gas Gyser-20% Solar Water Heater-72% Other( boiling through LPG, electric boiler)- 4% 11% 23% 25% 34% 0% 10% 20% 30% 40% Figure 12: Energy use for water pumping Proceedings of IOE Graduate Conference,
6 6.6. About rain water harvesting About 81% of the household don't have rain water harvesting system. Only 19% of the household have rain water harvesting in their homes. Despite the sufficient availability of rain water in the valley, due to lack of knowledge and information, most of residences doesn't harvest rainwater. shedding, solar PV inverters are recommended to use rather than inverter. 6% 2% 1% inverter- 61% 30% solar inverter- 30% torch- 6% Yes, 19% 61% Generator- 2% Figure 15: Backup used during load shedding No, 81% Figure 13: Rain water harvesting in homes 6.7. Installation of renewable sources of energy About 66% of the household have renewable sources of energy. Among those who have installed renewable energy in their house, 26% have solar water heater, 8% have solar PV, 34% have both solar water heater and solar PV installed. The use of renewable source of energy is growing in the valley and only 2/3 of household are acquainted with the renewable energy sources. There's a lot of potential of renewable energy penetration in the household sector Uses of inverter The inverter has been used mainly for lighting, then television, computer and laptops and some use for using fan and other appliances such as mobile charging. Applianaces Fan Laptop Computer Television Lights 1% 2% 20% 26% 53% 66% 0% 20% 40% 60% 80% Figure 16: Uses of inverter Figure 14: Installation of renewable sources of energy 6.8. Backup during load shedding Load shedding has become the usual problem of Kathmandu valley. To provide the backup during loadshedding, 61% of the household uses inverter, 30% uses solar inverter and 6% uses torch, 2% use generator and 1% use others sources such as candles. Only 1/3 of household has solar inverter which is renewable source of energy. The use of inverter has also helped in raising the electricity consumption in the household. Hence to reduce this energy consumption during load 604 No 34% Yes 66% Electricity bill per month Most of the household pay their monthly bill of electricity Nrs which is about 2% of their monthly income. About 52% household pay their bills of Nrs , 40% pay their electricity bill less than 1000 rupees and 6% of household pay within Nrs and 2% of household pay more than Nrs more than less than % 6% 40% Figure 17: Electricity bill per month 52% 0% 20% 40% 60% Energy Efficient Building in Kathmandu Valley
7 6.11. Waste Disposal Most of the household have their waster disposed privately. About 35% dispose waste privately, 32% disposes waste to municipal, 22% have mix way of disposing waste and 11% use composting method to dispose waste. In mix way of disposing, the waste is disposed by composting method for degradable material and for non degradable material they either dispose it to municipal or privately. Mix way- 22% Figure 18: Waste disposal system Cost for transportation Non renewable energy such as fossil fuel has been consumed in the household sector in large amount as petrol for transportation. About 7% of the monthly income is spent in transportation. About 29% spent Nrs , 16% spent Nrs , 31% spent Nrs and 11% spent above Nrs in transportation or in fossil fuel. Those who spent above Nrs spent about 10% of their monthly income in non renewable energy. Rs. above Rs Rs Rs Compost ing-11% 11% 16% Figure 19: Cost for transportation private- 35% municipa l- 32% 29% 31% 0% 10% 20% 30% 40% Average energy consumption per household From the household survey, the average energy consumption per household per day was found out. The electricity is highly consumed for room heating for winter i.e KWh per day. The various electronic equipment such as refrigerator, iron, oven, vaccum cleaner, etc. consumes about 0.73KWh. Electric fan and AC consumes about 0.56KWh which is less than equipment used in household. The average lighting consumes about 0.48KWh and TV consumes about 0.11KWh. The average energy consumption per household is 3.3KWh. The energy efficiency can be attained through reducing the heating demand of the, using energy efficiency equipments and lighting and through installation of renewable energy. The heating demand of can be reduced through passive solar technologies and energy efficient equipments. The cooling demand can be reduced through passive design of. While the use of energy efficient devices can helps to reduce the energy consumption in equipments Figure 20: Average energy consumption per household Average energy consumption per household in lighting Lighting consumes less than half KWh energy per day in household. About 50% of the household use tube light. Only 37% use CFL Lights, 12% still use incandescent bulb and 1% use Led Light. CFL light is found to be used only in housing community. The other residence s around the valley still uses tube light for most lighting. The use of LED light is found to be very nominal in houses primarily due to its high cost and lack of its information. 12% 1% 50% % CFL LIGHT TUBELIGHT BULB LED LIGHT Figure 21: Average energy consumption in lighting Proceedings of IOE Graduate Conference,
8 6.15. Cost of electricity per month per household The average cost of electricity per month is Nrs The yearly cost is Nrs and daily cost is Nrs Cost of energy for 10 years of referenced s The cost for energy is nearly three times higher in contemporary than in passive at present and for next 10 years. The daily cost of energy for contemporary is Nrs while for passive it is just Nrs The energy consumption for passive for lighting and other equipments is nearly half than contemporary. Whereas, there is no need for any energy for heating and cooling because of its passive solar design. The passive solar design helps in saving 60% of its total energy consumption for heating and cooling Figure 22 Comparative energy cost for 10 years 7. Heating Demand Analysis For the heating demand analysis, three scenarios have been assumed as base case scenario and improved case scenario I and II. The base case scenario represents the present scenario of in Kathmandu Valley. The other two scenarios represent the change of Base case scenario for analysis of heating loss from. 1. Base Case CONTEMPORA RY BUILDING cost for 10 years PASSIVE BUILDING From the study of referenced, the base case scenario has been generated. The base scenario represent the residential in Kathmandu valley which are constructed with RCC, cement, concrete, burnt brick, sand and use of either wooden windows and door or aluminium door and windows. The heating and energy demand has been shown in table 1. Likewise, the heating and energy demand of passive studied has also been shown in table 2. The U-value of contemporary residential is comparatively higher than passive. This results in the higher energy demand in the summer and winter time in contemporary residential. The energy consumption is nearly 4 times higher in contemporary than in passive since it doesn't have to use any devices to adjust with the climate in any season. Table 3: Calculation of U-value, Improved scenario I Calculation of U-value of improved contemporary (W/m2k) Cavity Brick wall (230mm brick wall+ 50mm cavity+110mmsun dried brick) Concrete roof with air cavity(floor finish+ wooden plank+air cavity+ rcc slab) Double glazed window Improved Case I In this case, the s are intervened with energy efficiency measures known. Here the heating demand of is examined from the U-value calculation of improved material and construction. Instead of single leaf wall structure, the heat loss can be minimized through cavity wall construction. Single glazed window has been replaced by double glazed window and insulation has been provided in the roof. Table 3 shows that heat loss through wall can be minimized about 38% than in the base case. Similarly, insulation in roof can also provide about nearly 47% saving in heat loss compared to base case. While changing the window from single glazed to double glazed can save about 38% reduction in heat loss. 3. Improved Case II Here the heating demand of is examined from the U-value calculation of improved material and construction. Instead of single leaf wall structure, the heat loss can be minimized through cavity wall construction along with sundried brick in inner leaf. Single glazed window has been replaced by double glazed window and insulation has been provided in the roof. Table 3 shows that heat loss through wall can be minimized about 60% than in the base case. Similarly, insulation in roof can also provide about nearly 76% saving in heat loss compared to base case. While changing the window from single glazed to double glazed can save about 38% reduction in heat loss. 606 Energy Efficient Building in Kathmandu Valley
9 Table 4: Calculation of U value, Improved case scenario II Calculation of U-value of improved contemporary (W/m2k) Cavity Burnt Brick wall (230mm brick wall+ 50mm cavity+110mm brick) 1.18 Concrete roof with air cavity(floor finish+ wooden plank+air cavity+insulation+ rcc slab) 1.5 Double glazed window 3.06 Brick wall Concrete roof Table 5: Comparison Table of U-Value Contemporary U-Value Passive Improve case I Improved case II Window The Comparison of U-value of contemporary, passive and improved cases shows that the overall U- value of Passive is lesser than all other cases. It implies that passive has comfortable environment during both winter and summer. Since orientation and site of can't be varied to any parameters, but improvement in its envelope, energy consumption can be reduced Figure 23: Comparison of U-value 8. Results and Discussion Brick wall Concrete roof Window This research has focused on study of energy consumption pattern of contemporary residential s in Kathmandu valley. From the research carried out following results have been found: 1. Heating and cooling consumes 60% of total energy consumption in contemporary. 2. The contemporary consumes 3 times more energy than the passive. 3. The cost for transportation, i.e. cost for non renewable energy, petrol account for 7% of the total income which is more than cost for total monthly electricity bill. 4. The cooking energy is highly dependent on LPG with use of electricity only for rice cooking. 5. The energy cost for equipment use is higher than for lighting use. 6. The average energy consumption is high for heating which is 1.21 KWh per day. Other electronic equipments such as refrigeration, oven, vacuum cleaner, etc. consumes 0.73 KWh energy per day. While cooling consumes 0.56 KWh and lighting consumes less than half KWh per day i.e KWh. 7. The comparative U-value of envelope of passive is lesser than Improved case I and II. 8. The cavity wall construction can minimize 38% heat loss than 9" thick wall. 9. The cavity wall with sun burnt brick outside and sundried brick inside can minimizes 60% heat loss through walls. 10. Double glazed window can reduce heat loss to 38% than single glazed window. 11. Similarly concrete roof with cavity can save47% heat loss while insulation along with cavity can save about 76% heat loss than concrete roof without insulation. This research is limited to study of contemporary residential in Kathmandu valley as the required passive or energy efficient is not available here. The study of energy efficient in Kathmandu valley has to be limited to study of only one passive of Kathmandu valley, Mato ghar of Buddhanilkantha. This research has not attempted to carry the direct comparison between the contemporary and passive but tends to analyze the consumption pattern and behavior of contemporary and passive. The study of passive been taken just for the reference study and to study possible best used techniques that can be applied to contemporary for energy efficiency. Beside it, this research has focused on energy efficiency through thermal performance of materials only, the water efficiency and waste management have not been considered. Proceedings of IOE Graduate Conference,
10 9. Conclusion and recommendations Energy efficiency in has become the growing issue for researcher all over the world. Construction of passive solar could significantly reduce the heating and cooling energy demand as shown by energy calculation of Passive in the case study. The improvement in contemporary can be achieved through improvement in envelope such as walls, roof and windows. The improvement of wall by cavity wall and roofing by insulation can reduced the energy consumption significantly. Improvement in glazing of window is must for increasing efficiency. The following recommendations are drawn from this research. Criteria Site Orientation Building form Wall Windows Roof Floor Contemporary Rectangular in shape Vary with site Passive Building Elongated in shape Oriented along east west direction at 10 inclination to axis Remarks for Improved contemporary Can be varied Preferred along eastwest direction Rectangular Rectangular Rectangular 9" thick brick wall Single glazed Flat rcc slab 5" thick Rcc slab 18"thick rammed earth Double glazed Insulated slope roof Insulated 4" thick cob floor wall with low U-value Double glazed Insulated roof insulated floor has lower u-value i.e W/m2k than the cavity wall with burnt brick at inner and outer leaf. This U-value is based on traditional of Kathmandu valley as user feels it more comfortable. Double glazed window of U-value 3.06 W/m 2 k is recommended to use. Beside thermal insulation it also provides sound insulation. The roof should be insulated with air cavity in between so as to allow air to flow in between. Air being the good insulator, along with other insulating material it provides great insulation. The roof with U-value of 0.67 W/m2k is recommended to use. References [1] IEA, 2010,World Energy outlook, International Energy Agency [2] CBS, 2011, National Population and Housing Census [3] WECS,2010 National Survey of Energy Consumption and Supply Situation in Nepal, Water and Energy Commision Secretariat [4] Thumann, Albert, Handbook of energy audits, 7th edition, The Fairmont Press, INC. [5] ICAEN( Institute Catala' d Energia)2004 Sustainable design manual, The Energy and Resource Institute, IHC Complex, Lodhi Road, New Delhi, India. [6] U-Values of Element, LABC, PDF, www. labc.uk.com [7] [8] [9] [10] Low Energy Building Design Guidelines PDF, [11] Heimo Staller, Angelika Tisch, IFZ, New technical solutions for energy efficient s, State of Art Report, Energy Efficient Building Design [12] Franfort, Kentucky, Energy efficient Building Design and Construction Practices, Research Memorandum no. 503 [13] Energy Efficient Building Methods For Tajikistan, GaIA Architects- Norges Naturvernforbund Energy consumption per day Energy cost per year 3.29 KWh 0.76 KWh Nrs Nrs For the general construction of wall, cavity wall with sundried brick in the inner leaf is recommended as it 608 Energy Efficient Building in Kathmandu Valley
THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.
THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT. A Diagrammatic representation of the relationship between the
1..GENERAL DATA 2. CLIMATIC DATA. Location
1..GENERAL DATA Location Szentendre, Downtown, Hungary Property Community centre of Szentendre, Public, Municipality of Szentendre Year of Building: End of 19th Century Present use (1) Community centre
Climate and Energy Responsive Housing in Continental Climates. The Suitability of Passive Houses for Iran's Dry and Cold Climate. Farshad Nasrollahi
Climate and Energy Responsive Housing in Continental Climates The Suitability of Passive Houses for Iran's Dry and Cold Climate Farshad Nasrollahi Table of Contents Abstract German Abstract Introduction
FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS
FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS 1 Ralf Lindberg, Professor Minna Korpi, M.Sc. Juha Vinha, Dr.Tech. June 11, 2008 Department of Civil Engineering, Tampere University of Technology 2 BACKGROUND
Sample Customer 123 Conservation Way TAMPA FL 33626 Tracking Number: 000675309
Thank you for completing the Online Home Energy Audit. Based on the answers that you provided in the questionnaire, the following is a complete analysis of your household's energy consumption. We have
Window Thermal Performance Optimization in Governmental Emirati Housing Prototype in Abu Dhabi, UAE
Window Thermal Performance Optimization in Governmental Emirati Housing Prototype in Abu Dhabi, UAE Abuimara, Tareq A 1 ; Tabet Aoul, Kheira A. 1 1 Department of Architectural Engineering, United Arab
HOW AN ENERGY EFFICIENT HOME CAN HELP THE ENVIRONMENT
HOW AN ENERGY EFFICIENT HOME CAN HELP THE ENVIRONMENT During the last century, concern about the environment increased, as issues such as global warming and the Greenhouse Effect convinced us that the
Energy'Saving,'Thermal'Comfort'and'Solar'Power'Information'Sheet'
Energy'Saving,'Thermal'Comfort'and'Solar'Power'Information'Sheet' We ve prepared this information sheet to help you to minimise energy consumption and energy costs while maximising thermal comfort at home.
IEA SHC Task 47 Renovation of Non-Residential Buildings towards Sustainable Standards
Date of revision: 15.6.2012 Osram Culture Centre Copenhagen, Denmark Valhalsgade 4, 2200 Copenhagen N 1. INTRODUCTION PROJECT SUMMARY Construction year: 1953 Energy renovation: 2009 No past energy renovations
Conservatory warm roof conversion system
Conservatory warm roof conversion system IS YOUR EXISTING CONSERVATORY ROOF: Too hot in summer or too cold in winter? Waste of valuable living space? Unable to relax to watch TV? Transform your conservatory
Passive house rehabilitation of post war residential building in Zug, Switzerland
Passive house rehabilitation of post war residential building in, Switzerland Owner: Erbengemeinschaft Ducret Architect: Miloni & Partner, Wettingen Energy concept designer: Zurfluh & Lottenbach, Luzern
Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669
Report Date: 04/03/2014 Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: 106178106 MPRN: 10301589669 About this Advisory Report Energy use in our homes is responsible for almost
Klosterenga, Oslo, Norway, 1998-2000 page - 1
Klosterenga, Oslo, Norway, 1998-2000 page - 1 Introduction Klosterenga is an urban revitalisation project close to the city centre of Oslo. The 3 apartments were built with a focus on energy saving. Next
HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS
HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS Saim Memon Philip C. Eames Centre for Renewable Energy Systems
Energy saving at home
Code of Practice on the efficient use of electricity Energy saving at home Energy saving information and advice from Power NI www.powerni.co.uk /savingenergy Energy saving Running costs Insulation Heating
Windows are one of the most important components of a
design concepts Arjun Kamal MAKING BETTER INDOOR ENVIRONMENTS WITH ENERGY-EFFICIENT WINDOW DESIGN An insight into the various technologies used for constructing windows, and an attempt at understanding
Net Zero Station Design for The Cooper Centre for the Environmental Learning in Tucson, Arizona: Improving the performance of existing buildings
Net Zero Station Design for The Cooper Centre for the Environmental Learning in Tucson, Arizona: Improving the performance of existing buildings Alya Al-Hashim 1, Lena Spiric 2,and Nader Chalfoun 3 1,2
Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls
PCA R&D Serial No. 415 Energy Use in Residential Housing: A Comparison of Insulating Concrete Form and Wood Frame Walls by John Gajda and Martha VanGeem 000 Portland Cement Association KEYWORDS Concrete,
BER Assessors Dwellings Technical Bulletin
BER Assessors Dwellings Technical Bulletin Issue No. 3/11 May 2011 Contents: 1 Window defaults in DEAP and use of DEAP Table 6a... 2 2 Solar Space Heating Systems in DEAP... 4 3 Storage and direct electric
CHAPTER 10: APPLIANCES AND LIGHTING
Chapter 10: Appliances and Lighting 151 CHAPTER 10: APPLIANCES AND LIGHTING According to the U.S. Environmental Protection Agency, appliances and home electronics account for 20% of energy bills in the
The Sino-Italy Environment & Energy Building (SIEEB): A model for a new generation of sustainable buildings
International Conference Passive and Low Energy Cooling 935 for the Built Environment, May 25, Santorini, Greece The Sino-Italy Environment & Energy Building (SIEEB): A model for a new generation of sustainable
This report presents the findings and recommendations of the assessment of energy use and
This report presents the findings and recommendations of the assessment of energy use and environmental stewardship of Arlington Street Church, Boston, MA. As stewards of the earth it is important that
Economics of Passive Solar and Zero Energy Homes
Economics of Passive Solar and Zero Energy Homes Jeff Tiller, PE ASU Energy Center / Department of Technology Southface North Carolina [email protected] 828-262-6355 Projected Residential Energy Use
School in Schwanenstadt, Austria
School in Schwanenstadt, Austria 1. INTRODUCTION PROJECT SUMMARY - building period 1960s - numerous expansions SPECIAL FEATURES - Renovation to meet Passive House Standard - decentralized ventilation system
main heating: pre1998 ducted warm air system main heating fuel: mains gas main heating SAP efficiency: 70.0% main heating controls: programmer
Archetype: 3250330 Archetype Description: 1965-1975, semi / end terraced dwelling, timber frame walls, oil / gas / electric warm air heating, E This archetype represents 823 dwellings, which accounts for
Electricity Demand, Forecast and Scenario Analysis of Shopping Malls, Kathmandu Valley
Proceedings of IOE Graduate Conference, 2015 pp. 333 338 Electricity Demand, Forecast and Scenario Analysis of Shopping Malls, Kathmandu Valley Kiran Babu Subedi 1 *, Rajendra Shrestha 2 1, 2 Department
Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:
PASSIVE Solar Design Solar Homes Catch the Sun Are you planning a new house? Discover how you can apply solar architecture principles to: keep your heating bills to a minimum enjoy the comfort of a warm
After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE
86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is
SAVE ENERGY AT HOME INSULATE AND AIR SEAL
SAVE ENERGY AT HOME INSULATE AND AIR SEAL Check the roof insulation level and add insulation to maintain minimum R-38 (6 of blown cellulose or equal). Use R-19 between frame or R-10 rigid insulation for
ENERGY AUDIT IN THE KACST BUILDING
ENERGY AUDIT IN THE KACST BUILDING S. M. Hasnain, S. H. Alawaji, A. M. Al-Ibrahim and S. M. Smiai Energy Research Institute (ERI) King Abdulaziz City for Science and Technology (KACST) P.O. Box 6086, Riyadh
Energy Efficiency in Buildings
Energy Efficiency in Buildings Supplemental Guide to SANS 10400-XA & SANS 204 V. 3.0 Registered to: The Drawing Studio Image: digitalart / FreeDigitalPhotos.net Report Date: 26 August 2014 Practice Name:
Key energy-efficient features of your new home
Key energy-efficient features of your new home Your thermal envelope The thermal envelope, or shell, of your home (walls, roof and floor) is designed to keep you dry and comfortable. It protects you from
Identify ways to save energy in the home, either through energy efficiency or energy conservation.
Home Energy Audit TEACHER GUIDE Students will learn about energy conservation and energy efficiency. By conducting an audit of their own homes, they will learn to identify energy-efficient features and
Energy efficient home design
Energy efficient home design GUIDELINES How an energy efficient home can help you live in comfort and save money An energy efficient home is designed to provide shade and allow cooling breezes to enter
Rainwater Harvesting
Rainwater Harvesting With climate change now a reality rather than a speculated possibility, the demand on water resources has gone up, whilst the amount of water available for supply has gone down. Forth
Case Studies of Successful Code for Sustainable Homes Projects
Case Studies of Successful Code for Sustainable Homes Projects Sustainable Homes publish the Sustainable Homes Index For Tomorrow (SHIFT) and are a leading trainers of Code for Sustainable Homes assessors.
ANSI/ASHRAE Standard 140-2004 Building Thermal Envelope and Fabric Load Tests
ANSI/ASHRAE Standard 140-2004 Building Thermal Envelope and Fabric Load Tests DesignBuilder Version 1.2.0 (incorporating EnergyPlus version 1.3.0) - June 2006 1.0 Purpose The ANSI/ASHRAE Standard 140-2004
Energy saving tips for home
Energy saving tips for home Contents 1 Heating and cooling 2 Computers, TVs and general appliances 4 Kitchen and cooking 6 Washing and drying 8 Lighting 9 Outdoors 9 We re all looking for ways to cut back
Twinning «Improvement of the Energy Efficiency in Turkey»
Twinning «Improvement of the Energy Efficiency in Turkey» SECTOR BUILDING WORKSHOP Thermal Rehabilitation of Existing Buildings and Energy Building Code Residential energy efficiency overview in Ankara:
Building Condition Assessment Report
C2 - Nurses Resident (aka Administration) Building Condition Assessment Report Asset Address Address Construction Year Size (Gross Floor Area) Asset Type Floors Above Ground Inspection Date C2 - Nurses
Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses
Passiv Haus Institut Passivhaus Dienstleistung GmbH Dr. Wolfgang Feist Rheinstr. 44/46 Rheinstr. 44/46 D-64283 Darmstadt D-64283 Darmstadt www.passiv.de www.passivhaus-info.de Certification as "Quality
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries
Norwegian Tax Authority - Oslo Norway
1. INTRODUCTION Norwegian Tax Authority - Oslo Norway PROJECT SUMMARY Year of construction - 1980 No previous energy renovations SPECIAL FEATURES Main topics in the renovation are: High insulated pre fabricated
Green House, Hungary
Further information Skanska AB www.skanska.com Contact Noel Morrin, SVP Sustainability & Green Support [email protected] Green House, Hungary Case Study 109 Aspects of Sustainability This project
Concept for a DC low voltage house
Concept for a DC low voltage house Maaike M. Friedeman 1 Elisa C. Boelman Dr. Eng., MBA 1 Arjan van Timmeren, Ir. 1 Joop Schoonman, Prof. Dr. 2 1 TU Delft, Faculty of Architecture, dept. of building technology,
THE ELECTRIC HOOKUP. 1. Determine the wattage of various household appliances. 2. Calculate the number of kilowatt-hours used by appliances.
Objectives: The student will do the following: THE ELECTRIC HOOKUP 1. Determine the wattage of various household appliances. 2. Calculate the number of kilowatt-hours used by appliances. 3. Identify the
Development Services City of Lawrence, KS
Development Services City of Lawrence, KS Building Planning Table R301.2 (1) Climatic & Geographic Design Criteria Building Planning The design criteria for wind speed increased from 90 MPH to 115 MPH.
ANALYSIS OF INDOOR PERFORMANCE OF HOUSES USING RAMMED EARTH WALLS. Veronica Soebarto The University of Adelaide, Adelaide, Australia
Eleventh International IBPSA Conference Glasgow, Scotland July 27-30, 2009 ANALYSIS OF INDOOR PERFORMANCE OF HOUSES USING RAMMED EARTH WALLS Veronica Soebarto The University of Adelaide, Adelaide, Australia.
Building Condition Assessment Report
Building Condition Assessment Report Asset C3c - Oak Terrace Cottage 121 Address Riverview Lands, 2601 Lougheed Highway, Coquitlam, BC. V5C 4J2 Construction Year Size (Gross Floor Area) 1920. 2,553 Sq.Ft.
The Importance of Building Criteria on Cooling Energy Demand of a Low Cost Residential House: Thailand Case Study
The Importance of Building Criteria on Cooling Energy Demand of a Low Cost Residential House: Thailand Case Study WARAPORN RATTANONGPHISAT 1,2,*, FEDERICO M. BUTERA 2, R.S. ADHIKARI 2 AND CHALERMPORN YOOPRATETH
Green Architecture and Construction
Green Architecture and Construction Prof. Dr. Soontorn Boonyatikarn Center of Excellence Building and Environmental Technology, Department of Architecture, School of Architecture, Chulalongkorn University,
Case Study Family Room Renovation 3br family home, Melbourne
Family Room Renovation 3br family home, Melbourne In a Nutshell With time and budget constraints we often renovate just one room at a time. This case study looks at a family room renovation where the key
Integrated Solar Radiant Systems
Integrated Solar Radiant Systems William Shady PE President Topics Radiant heating Indoor air quality Radiant Cooling Project Photos Questions and answers The goal for our clients Healthy Comfort Why Radiant
Exemplary Retrofitting of an Old School in Stuttgart - EROS -
Exemplary Retrofitting of an Old School in Stuttgart - EROS - City of Stuttgart, Summary The objective of the project was to demonstrate the potentials of a retrofitting process for a typical school in
Solar Aquaponics Designing a 100% Solar Aquaponics Greenhouse
Solar Aquaponics Designing a 100% Solar Aquaponics Greenhouse Dan Chiras, Ph.D. Director, The Evergreen Institute Gerald, MO 63037 www.evergreeninstitute.org Topics Creating a 100% solar operation Efficiency
IES <Virtual Environment> Tutorial. Apache Sim (Version 6.0)
IES Tutorial Apache Sim (Version 6.0) Introduction This tutorial will begin by showing you how to use the Building Template Manager (BTM) to create thermal and construction data for
Holistic Approach in Delivering Government Buildings The Low Carbon Concept
International Conference on Planning for Low Carbon Cities 22 May 2009 Holistic Approach in Delivering Government Buildings The Low Carbon Concept Ir. HO Sai-king, Assistant Director (Building Services),
Energy Efficiency HOSPITALITY. www.energia.ie
Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real
Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro
Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro Dept. Building Environment Science &Technologies Politecnico di Milano Italy Research funded
New technical solutions for energy efficient buildings
- New technical solutions for energy efficient buildings State of the Art Report Energy efficient building design Authors: Heimo Staller, Angelika Tisch, IFZ Oct. 2010 Background In the building sector
Module 2.2. Heat transfer mechanisms
Module 2.2 Heat transfer mechanisms Learning Outcomes On successful completion of this module learners will be able to - Describe the 1 st and 2 nd laws of thermodynamics. - Describe heat transfer mechanisms.
Improving thermal insulation of concrete sandwich panel buildings
Improving thermal insulation of concrete sandwich panel buildings Jørgen Munch-Andersen Danish Building Research Institute, Aalborg University LCUBE conference, Vienna 17-18 April 2007 Outline A general
What a good idea! www.philcoppell.co.uk. Turn your conservatory into an all-year-round living space. www.philcoppell.co.uk
What a good idea! Turn your conservatory into an all-year-round living space CONTACT ONE OF OUR TEAM ON 01706 396 203 TO ARRANGE YOUR FREE QUOTE & INFORMATION PACK Before Transform your conservatory into
Carbon Footprint of CMC Hospital for 2013
Carbon Footprint of CMC Hospital for 2013 Carbon footprint of CMC Hospital campus was estimated for the year 2011 and 2012 and the total CO2e emission was estimated at 15271.74 CO2e tons and 15456.61 CO2e
research highlight Highly Energy Efficient Building Envelope Retrofits for Houses
research highlight June 2012 Technical Series 12-103 Highly Energy Efficient Building Envelope Retrofits for Houses introduction In Canada approximately 30% of all energy is consumed in buildings, with
CASH SAVING BEATS ECO CONCERNS AS MAIN REASON TO GREEN YOUR HOME
Press Release CASH SAVING BEATS ECO CONCERNS AS MAIN REASON TO GREEN YOUR HOME Saving money is now our main motivation for carrying out green home improvements ahead of concerns for the environment. One
D5.3 Energy audit report
Project Acronym: EPLACE Project Title: Eco public PLAtform for smart green CityzEn s living labs Call identifier: CIP-ICT-PSP Call 6 Theme 1: ICT for SMART CITIES Objective1.1: Smart Urban digital services
The Thermal Performance of Traditional Residential Buildings in Kathmandu Valley. Sushil B. Bajracharya
TUTA/IOE/PCU Journal of the Institute of Engineering, Vol. 10, No. 1, pp. 172 183 TUTA/IOE/PCU All rights reserved. Printed in Nepal Fax: 977-1-5525830 The Thermal Performance of Traditional Residential
3.2 Bioclimatic Site Conditions
ZERO ENERGY RETROFIT: CASE STUDY OF A CHALET IN AIN-SUKHNA, EGYPT Shady Attia Architecture et Climat, Université Catholique de Louvain, 1348- Louvain La Neuve, Belgium [email protected] ABSTRACT
Heating and cooling. Insulation. Quick facts on insulation:
Heating and cooling Heating and cooling your home can be one of the biggest users of energy. Efficency in this area can bring great savings. Heating and cooling depend on many contributing factors. The
BPC Green Builders. Green building for new and existing homes. Health Comfort Energy
BPC Green Builders Green building for new and existing homes Health Comfort Energy Mechanical Systems Installed HVAC Systems Primary energy source large, roof mounted, solar thermal array (AET flat plate)
BER Assessors Dwellings Technical Bulletin
BER Assessors Dwellings Technical Bulletin Issue No. 2/12 April 2012 Contents: 1. SUPPLEMENTARY ELECTRIC WATER HEATING IN SUMMER... 2 2. PITCHED ROOF U-VALUE CALCULATIONS... 8 2.1. PITCHED ROOF, INSULATED
Energy Audit Data Collection Form
SAVING ENERGY IN COMMERCIAL BUILDINGS Energy Audit Data Collection Form Site Data Building Name Address Building Square Footage (ft 2 ) Age of Building (years) Date of Last Major Renovation Purpose of
Achieving Net Zero. Bradley Berneche, President Alouette Homes. National Marketing Committee Canadian Home Builders Association Ottawa, June 6, 2008
Achieving Net Zero Bradley Berneche, President Alouette Homes National Marketing Committee Canadian Home Builders Association Ottawa, June 6, 2008 Overview Who Is Alouette Homes? The EQuilibrium Initiative
Home Energy Efficiency and Conservation: Call to Action. July 23, 2015 Dave Blake and David Wood REEP Green Solutions
Home Energy Efficiency and Conservation: Call to Action July 23, 2015 Dave Blake and David Wood REEP Green Solutions Today s Agenda Background Understanding where you are: Energy Usage EnerGuide Home Energy
Uncovering Myths and Opportunities of Advanced Building Envelope Technologies: BIPV, Roofing and Windows
Uncovering Myths and Opportunities of Advanced Building Envelope Technologies: BIPV, Roofing and Windows Marc LaFrance Technology Development Manager US Department of Energy Building Technology Program
Residential HVAC Load Sizing Training October 14, 2015. David Kaiser Green Code Plan Reviewer
Residential HVAC Load Sizing Training October 14, 2015 David Kaiser Green Code Plan Reviewer DCRA - Green Building Division Regulations of green codes including: Green Building Act Green Construction Code
Home Energy Evaluation Report
Home Energy Evaluation Report Nate Begeman, 1550 Saint Francis Dr San Jose, CA 95125 Air Infiltration Current Air Leakage 2,852 Current Air Changes Per Hour 0.91 Recommended Air Changes Per Hour 0.35 Percent
Selecting Energy Efficient New Windows in Florida
Selecting Energy Efficient New Windows in Florida www.efficientwindows.org January 06 Zones. Meet the Energy Code & Look for the Windows must comply with your local energy code. Windows that are certified
Building Control Guidance Note
Elements Renovation / Replacement. Issued 25/01/13 Rev a Page 1 of 9 (Applies to both Domestic and Non-Domestic Premises) Works relating to thermal elements can arise in building an extension, a material
2014 British Columbia Building Code Changes
District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most
Mission 7: Saving Energy
Mission 7: Saving Energy How can we save energy? Converting one type of energy to another often damages the environment. For example, burning coal to make electricity causes air pollution. That s why we
Passiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses
Passiv Haus Institut Dr. Wolfgang Feist Rheinstr. 44/46 D-64283 Darmstadt www.passiv.de Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses Passive Houses are
CONSTRUCTION COSTS INDEX FOR RESIDENTIAL BUILDINGS, SLOVENIA
CONSTRUCTION COSTS INDEX FOR RESIDENTIAL BUILDINGS, SLOVENIA METHODOLOGICAL EXPLANATIONS PURPOSE OF THE STATISTICAL SURVEY LEGAL BASIS FOR THE SURVEY OBSERVATION UNITS COVERAGE SOURCES AND METHODS OF DATA
Introduction to Energy Codes & Green Building Programs
Introduction to Energy Codes & Green Building Programs David Neiger B.S. Arch, LEED AP Homes, Certified HERS Rater Principal Populus Sustainable Design Consulting Why green homes? The Building Sector:
TIPS ON ENERGY SAVING
TIPS ON ENERGY SAVING IN HOME APPLIANCES AND ELECTRICITY SAFETY The Domestic Sector accounts for 30% of total energy consumption in the country. There is a tremendous scope to conserve energy by adopting
Delivering on innovation and market uptake. Best-in-cases of nzeb. Ramon Pascual Bucharest May 8th, 2015
www.zebra2020.eu Delivering on innovation and market uptake. Best-in-cases of nzeb Ramon Pascual Bucharest May 8th, 2015 Outline nzeb Database Best in cases of nzeb Climates in Europe Preliminary results
MAKING YOUR HOME WARMER
MAKING YOUR HOME WARMER INTRODUCTION This guide has been written to help householders take the first steps to improving the homes they rent or own, making them warmer and cosier to live in, and less expensive
Diego Ibarra Christoph Reinhart Harvard Graduate School of Design
Building Performance Simulation for Designers - Energy DesignBuilder // EnergyPlus Tutorial #2 Load Schedules GEOMETRY LOADS RESULTS Diego Ibarra Christoph Reinhart Harvard Graduate School of Design OVERVIEW
Extra Low Energy Housing in Ireland How far should we go to the Passive House? Jonathan Jennings Head of R&D Kingspan Century Homes
Extra Low Energy Housing in Ireland How far should we go to the Passive House? Jonathan Jennings Head of R&D Kingspan Century Homes Current Status % CO 2 emissions Transport 30% Agriculture 2% Housing
Residential Energy Consumption: Longer Term Response to Climate Change
24 th USAEE/IAEE North American Conference July 8-10, 2004, Washington, DC Residential Energy Consumption: Longer Term Response to Climate Change Christian Crowley and Frederick L. Joutz GWU Department
Scenario analysis of Carbon Trade for Energy Efficient Renovations of. Operation Manual (take Beijing as an example)
Scenario analysis of Carbon Trade for Operation Manual (take Beijing as an example) 1 st step: choose cities Choose the target city in the list ranked by energy consumption demand. As shown in Fig. 1,
ENERGY AUDIT. Project : Industrial building United Arab Emirates (Case study) Contact person (DERBIGUM):
ENERGY AUDIT Project : Industrial building United Arab Emirates (Case study) Contact person (DERBIGUM): Leonard Fernandes DERBIGUM project reference : UAE -2014 - EA 103 Author : Daniel Heffinck (DERBIGUM)
Consider How can you collect solar energy for use in your school? What are other alternatives?
5 a 5 Energy Sources a - Energy from the sun Purpose To explore sourcing our energy from the sun Key concepts Solar energy is a natural and renewable resource Heat energy from the sun can be used to heat
Your DIY home energy checklist.
Your DIY home energy checklist. Assessing your building envelope (the structure and everything outside your home). Your building envelope covers the structural elements and everything on the outside of
ResearcH JournaL 2009 / VOL 01.01. www.perkinswill.com
ResearcH JournaL 2009 / VOL 01.01 www.perkinswill.com PERKINS+WILL RESEARCH JOURNAL / VOL 01.01 05. CONTEXT BASED DESIGN OF DOUBLE SKIN FACADES Climatic Considerations During the Design Process Ajla Aksamija,