ENERGY AUDIT IN THE KACST BUILDING
|
|
|
- Hilary Hart
- 9 years ago
- Views:
Transcription
1 ENERGY AUDIT IN THE KACST BUILDING S. M. Hasnain, S. H. Alawaji, A. M. Al-Ibrahim and S. M. Smiai Energy Research Institute (ERI) King Abdulaziz City for Science and Technology (KACST) P.O. Box 6086, Riyadh 11442, Saudi Arabia. Abstract A six storey office administration building of KACST was selected to conduct an energy audit. This new building is in use since 1996 and having well-insulated walls and roofs and different types of lighting lamps. Building air conditioning system is comprised of three air cooled reciprocating chillers, three pumps and four air handling units (AHUs). This paper presents measured values of actual electrical energy consumed by individual chillers, AHUs, different lighting systems, office equipment and other associated electric appliances used in the building. The results show that daily air conditioning load comprises 75% of the building load during peak summer period. Whereas the other major measured loads are 11.2% and 10% for interior lights and office equipment respectively. Nevertheless, the uses of programmable thermostat and ice thermal storage are suggested to be incorporated in the building for energy and power savings. 1. Introduction In the last two decades, electrical energy consumption in the Kingdom of Saudi Arabia has increased rapidly. This is mainly due to the rapid development and heavily subsidy of electricity costs (tariff ranges between 5 to 20 Halalas/kWh) [1]. This requires a huge investment either for building new power plants or upgrading the existing electric power systems. The electric utilities in the Kingdom face problems of peaking hours. The demand is very high during summer, mainly due to air conditioning consumption, lack of thermal insulation usage in most of the buildings as well as the implementing of the proper methods of energy conservation and the appropriate techniques for load management [2]. As a result, energy conservation became an important target for the Kingdom. Several efforts have been accomplished, however, they are not at the expectation and not more than 3-4 % at the country level has been achieved [3]. One of the essential goals of the Ministry of Industry and Electricity (MIE) is the reduction of peak load by 20% (at least) during summer as well as reducing energy consumption by 30% [3]. Therefore, the MIE started advising the customers to reduce their loads by supplying the energy conservation methods and techniques. At the same time electric utilities guide the customers and follow-up their efforts to achieve the established goals. First step towards achieving the MIE goals for energy conservation and peak load reduction, is to conduct an energy audit in a building and find out the areas for energy and power savings. To the best of the knowledge of the authors, measured experimental values of actual electrical energy consumption by individual equipment: chillers; air handling units; different lighting systems; office equipment and other associated electric appliances in an office building are not complete in the literature. This paper presents an energy audit in a newly constructed multi-storey Saudi office building and also identifies the areas for energy and power savings therein. 2. Building Design and Orientation The King Abdulaziz City for Science and Technology (KACST) based in Riyadh are having a number of multi-storey office buildings. A sixstorey office administration, building-26 of KACST, is being selected for conducting the energy audit and to propose energy conservation therein. The building represents a typical example of a Saudi office building. The building is rectangular in shape and longitudinally oriented in east-west axes, and all around exposed to solar radiation. The exterior of the building is composed of tented-double glazed windows (46% of the total area) and the remaining are of composite metallic walls. Total floor area of the building is equivalent to 7384 m 2. Normally, the building is occupied from 0730hrs to 1530hrs five days a week (Sat- Wed) and the number of occupants exceeds 150. Some personnel remain in the building up to 2200hrs. 3. Electrical Power Supply to the Building Electricity to the building is supplied through three transformers. Each transformer has an energy
2 meter. Out of these three, one transformer supplies power to all three chillers. The power and energy profiles of this transformer were monitored by an electric load analyser. The sequence of equipment operation and other details are given in the following sections. 3.1 Non Air Conditioning Equipment in the Building An inventory of office equipment, internal/external lights and other electrical appliances in the building has been made. It has been observed that the operating time of each equipment vary randomly. Total 2072 lighting fixtures of different individual rated power are used in the building. The total accumulated rated power is equivalent to kw. 3.2 Air Conditioning Equipment in the Building The cooling load of the building is supplied by three 30GB-150 Flotronic II, Air Cooled Reciprocating Chillers. The capacity of each chiller is 527 kw (cooling). These chillers are situated 80 meters away from the main building. Two chilled water pumps are used to pump chilled water from chillers to the air handling units (AHUs), situated at the roof level (sixth floor) of the building. The chilled water is pumped from chiller plant to the HVAC plant rooms in the building through 350 meter pre-insulated steel piping. All the three chillers are used to supply the peak cooling demand during the peak hours of summer season. The HVAC system is a variable air volume system. There are four AHUs serving the building. Each AHU supplies air at a constant temperature and a variable volume to the Variable Air Volume (VAV) terminal units, located in the ceiling voids of the office areas. Each VAV unit (or units) is controlled by a wall mounted thermostat. While the AHUs are controlled by the Building Automation System (BAS) and the VAV/CAV(control air volume) units are controlled by room thermostat. Control of comfort conditions inside the building is achieved through the use of the on-off room thermostats, which can be set at a desired temperature by the user s. 4. Electrical Power Measurement As described earlier, three transformers supply electrical power to the building. Two transformer out of three, supply power to all the electrical load except chillers. The following section present methodology for measurement and results obtained from these measurements 4.1 Measurement Methodology, Results and Discussion The electrical equipment in the building, such as computers, air handling units, etc., have various rating power and different function as well as different operational time. It has been observed from monitoring the building that all equipment are being used for different period of time. For example, the daily average operating time of each personal computer is 12 hours. Operational time of other equipment have also been estimated. As described earlier, two transformers supplying electric power to all the equipment located in the building, and each transformer has an energy meter. Energy meter readings from these transformers have been recorded on hourly basis. The electric load of supply air fan (SAF), return air fan (RAF), and exterior lights were measured through load analysers. The remaining load, such as office equipment, lighting, miscellaneous load (for instance, electric cookers, hand dryers, electric water heaters), etc. of the building is estimated through two methods. The first method is an estimation on the basis of the equipment rated power and operational time duration. Table. 1 presents a list of all electrical equipment used in the building and their rated power. The table shows the total installed power equivalent to 680 kw. The second method is a determination procedure by calculating the difference obtained from the summation of the measured energy consumption of SAF, RAF, and exterior lights from the total energy meter reading. The illuminious measuremenin different area of the building was also conducted using LUX meter. Instantaneous measurements of power drawn by the motors of the compressors, the pumps and the fans were made using power transducers as well as electric load analyser. Different measurements of these supply and return chilled water temperature, power, ambient temperature and relative humidity were recorded periodically using a data logger. Data were sampled every 15 minutes. Those information were off-loaded to a personal computer for analysis. Table 1. List of electrical equipment used in the KACST s building Equipment Quantity Total Rated Power (kw)
3 Chillers Condenser fans Distributions pumps Supply fans 4 58 Return fans 4 32 Office equipment Interior lighting External Lights Exhaust fans Power for Communication Humidifiers Electric Cookers Hand Dryers Electric Water Heaters Lifts 3 37 Table 2. shows the quantities and their rated power of all types of office equipment in the building. This table also reveals accumulated rated power of different equipment equivalent to 114 kw. It has been also found that the operational period of all equipment is dependent on the occupancy level. The total daily energy consumption by office equipment is found to be equivalent to 770 kwh. The daily average energy consumption by different non-air conditioning equipment is worked out according to the occupancy level as shown in Table. 3. This table shows that office equipment and interior lighting consume 40% and 45% respectively of the total non-air conditioning load. The table also shows that daily non-air conditioning energy consumption in the building is around 1263 kwh during 100% occupancy level. Similarly, the power profiles of chillers, SAF, RAF, pumps are obtained on regular interval. The results of those measurements are summarised in Table. 4, categorised according to the occupancy level. Table 2. Quantity and rated power of office equipment used in the KACST s building Equipment Total Quantity Rated Power (kw) Daily Energy Consumption (kwh) Personal Computer Printers Photocopy Miscellaneous (a) Miscellaneous (b) Miscellaneous (c ) Miscellaneous (d) (a): Typewriter, calculator and paper cutter; (b): Fax machine; (c): TV, VCR, Overhead projector; (d): Water cooler, refrigerator, coffee machine, vacuum cleaner. Note: All similar equipment have different power rating
4 Table 3. Average daily non-air conditioning energy consumption (kwh) in KACST s building Time period (hours) 00:00 to 07:00 07:00 to 15:30 15:30 to 00:00 Occupancy Level (%) Office Equipment Interior Light External Light (a) Exhaust Fans Telcommunica tion Miscellan -eous (b) Total (kwh) Total Energy (kwh) % age Contribution (a) Operational Time from 18:00 to 06:00 (b) Miscellaneous : Electric cookers, Hand dryers, Electric water heaters and lifts AHUs AI-Us 17 % Pumps 4 % Interior Lights 11.2 % Chillers 54 % External Lights 1.1 % Office Equipment 10 % Exhaust Fans & Telecommunication 0.5 % Miscellaneous Items 2.2 % Figure 1. Total daily electrical energy consumption (kwh) in the KACST s building Table. 4. Daily Energy Consumption (kwh) for facilitating Air Conditioning in KACST s building Time Period (hrs) Chillers & Fans Pumps Supply Air Fan Return Air Fan 00:00-07: :00-15: :30-00: Total
5 It has been found that total daily energy consumption in the building-is equivalent to 5879 kwh and 1946 kwh by air conditioning and non air conditioning equipment respectively. Figure. 1 shows that 75% of energy is consumed by the air conditioning equipment and the rest is used by the interior lights, office equipment, etc. Within the air conditioning system 72% consumed by chillers, 22.5% by AHUs and 5.5% consumed by pumps. Summation of all electrical energy measurements consumed by different equipment in the building revealed that the total monthly energy consumption is equivalent to 228,459 kwh. An area-wise survey of LUX level was conducted at ten different locations on each floor. Table. 5. shows average LUX level in different areas of the building. It has been found that 11.2% of total daily energy is consumed just for energising interior lights. This can be reduced by using timers and occupancy sensors especially in offices. Table. 5. Average Illuminance levels in different areas of the KACST s building Area Measured LUX Level Recommended LUX values * Offices (north side) Offices (south side) Partitioned Offices 448 Corridors / passages /150 Mosque 400 Lift lobby /150 * Manual of LUX meter from RS Components Limited 5. Suggestions for Energy and Power Savings Salient climatic feature of Saudi Arabia is the long summer period of 7 months with an average daytime ambient temperature ranging from 42 C to 48 C. Cooling of buildings is therefore essential, requiring large demand of electrical power/energy (see Fig. 1). Following are the some of the proposals to be considered for energy and power saving in an office building. 5.1 Use of Programmable Thermostat Most of the office buildings in the Kingdom are occupied for part of the day. The A/C system in these buildings, however, continue to operate at the set conditions throughout the day, for all days of the week. It has been observed in the buildingunder investigation, that chillers and AHUs were running even after occupied time schedule on working days as well as on non-working days. The operation of A/C system was continued till the outside air temperature reduces to 38 C. These preliminary results reveal, that the existing operation of HVAC in the building consuming enormous amount of electrical energy for running chillers as well as AHUs after office hours on working days even on non-working days. One of the way to conserve electrical energy in the building, is to change the sequence of operation of AHUs as per actual cooling requirement of each zone after office hours on working and nonworking days. Programmable thermostats, have the facility to set desired room temperatures for different periods of the day and for different days of the week. They are the excellent device to save energy in the building with part-of-day occupancy. However, it has an adverse effect on the peak cooling demand as a result of the thermal energy stored in the thermal mass of the building. The increase in peak cooling demand results in an increase in the air conditioning system capacity and the demand on power supply. The problem is more critical on the first day (Saturday) after the weekend. Pre-cooling the building few hours prior to its occupancy schedule can minimise this negative impact. A comprehensive study is required to find out the precooling period of the building with different temperature offset in order to save energy and reduce the day-time cooling demand. 5.2 Use of Single Water Pump At present, two chilled water pumps were always in operation irrespective of the number of chillers in use. During the non-occupancy period of the building in summer time and during the months of
6 November to March, the building cooling demand can be comfortable met by a single chiller. Under such operating conditions, the water flow rate of 600gpm was higher than the design value, resulting in a temperature drop of less than 3 C across the chiller. Use of single water pump with higher chilled water temperature setting to 7 C was found satisfactory after conducting an experiment. Operation of the system with one chilled water pump can reduced the motor power around 7 kw. There are other additional advantages such as reduction in pumping heat and improved chiller performance due to the increased temperature of leaving chilled water. 5.3 Ice Thermal Storage It has been observed that if cooling is generated and stored during low demand night-time (off-peak period) for later dayt(on-peak period) use, more peak capacity would be available for other uses, and night-time capacity of the power plant would be more fully used. By this way the on-peak energy consumption will be shifted to off-peak periods. Hasnain [4] explained that installation of off-peak ice based air conditioning system in new Saudi office buildings will reduced peak electric load by 20% and peak cooling load by 30%. As peak electrical load of a building is reduced by 20% with storage, therefore there will be savings on: new power connection charges; costs of reduced size of transformer & switchgear. 6. Concluding Remarks This paper presents measured values of actual electrical energy, consumed by individual chillers, air handling units, different lighting systems, office equipment and other associated electric appliances used in the multi-storey KACST s administration building-26. The building represents a typical Saudi office building. It has been found that 75% of energy is consumed by the air conditioning equipment, 11.2% by the interior lights, 10% by office equipment, etc. in this building. Within the air conditioning system 72% consumed by chillers, 22.5% by AHUs and 5.5% consumed by pumps. This paper also identified areas for energy and power savings in an office building in order to achieve the MIE goals for energy conservation and peak load reduction. Methodology for use of programmable thermostats and use of single water pump in an existing building can be adopted for energy conservation. Whereas, incorporation of ice thermal storage system with the conventional central air conditioning system is found to be, one of the power saving tools, particularly in new installations. Acknowledgements The authors wish to acknowledged the support and help of Engr. Mohammed I. Al-Hussani (Director General, General Support Services, KACST) and his colleagues for arranging different modifications in the existing set ups, as required from time to time for experimental measurements. References 1. Ministry of Industry and Electricity (MIE), Electricity Growth and Development in the Kingdom of Saudi Arabia up to the year 1417H (1996/1997G), Smiai, S., Alawaji, S., and Elani, U. Energy Management and its Conservation Equipment Proc. of the 4 th Saudi Engineering Conference, Jeddah, Saudi Arabbia, Nov. 5-9, Al-Tuwaijri, A., The Impact of Energy Conservation Programs on the Long-Term Plan of Electricity in the Kingdom of Saudi Arabia, Proc. of the 17 th Congress of the World Energy Council, Houston, Texas, USA, Sept , 1998, Vol. 2, pp Hasnain, S. M., Alawaji S. H., Al-Ibrahim A. M. and Smiai, S. M., Applications of Thermal Energy Storage in Saudi Arabia, International Journal of Energy Research, 1999 [in press].
Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues
Design Guide Retrofitting Options For HVAC Systems In Live Performance Venues Heating, ventilation and air conditioning (HVAC) systems are major energy consumers in live performance venues. For this reason,
Code of Practice for Building Energy Audit
Code of Practice for Building Energy Audit 2012 Code of Practice for Building Energy Audit Table of Contents Page No. 1. Introduction 1 2. Interpretations 1 3. Application 4 4. Technical Compliance with
HEATING, VENTILATION & AIR CONDITIONING
HEATING, VENTILATION & AIR CONDITIONING as part of the Energy Efficiency Information Grants Program Heating and cooling can account for approximately 23 % of energy use in pubs and hotels 1. Reducing heating
SAVE ENERGY AT HOME INSULATE AND AIR SEAL
SAVE ENERGY AT HOME INSULATE AND AIR SEAL Check the roof insulation level and add insulation to maintain minimum R-38 (6 of blown cellulose or equal). Use R-19 between frame or R-10 rigid insulation for
Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now
Fact Sheet #6 Air Conditioning In this fact sheet you will discover: The opportunity for energy efficiency How air conditioning works Low cost actions to reduce energy usage now Investments to reduce costs
Applying Schedules and Profiles in HAP
This HAP e-help discusses the importance of properly applying schedules and profiles in HAP. We will also discuss potential misapplications of these user inputs. First, we need to understand the differences
Energy Efficiency Tips for Businesses
Energy Efficiency Tips for Businesses Top 10 Tips Lighting Tips Heating and Cooling Temperature Control Office Equipment Laundry Service Refrigeration Equipment Food Service Equipment Employee Involvement
CONCEPTUALIZATION OF UTILIZING WATER SOURCE HEAT PUMPS WITH COOL STORAGE ROOFS
CONCEPTUALIZATION OF UTILIZING WATER SOURCE HEAT PUMPS WITH COOL STORAGE ROOFS by Dr. Bing Chen and Prof. John Bonsell Passive Solar Research Group University of Nebraska-Lincoln Omaha campus and Richard
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries
Lesson 36 Selection Of Air Conditioning Systems
Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section
CHAPTER 8 HVAC (Heating, Ventilation, and Air-Conditioning)
CHAPTER 8 HVAC (Heating, Ventilation, and Air-Conditioning) Objectives Survey current HVAC system(s), operating procedures, and maintenance schedule. Analyze results of energy audit for HVAC system(s)
HVAC Processes. Lecture 7
HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump
D5.3 Energy audit report
Project Acronym: EPLACE Project Title: Eco public PLAtform for smart green CityzEn s living labs Call identifier: CIP-ICT-PSP Call 6 Theme 1: ICT for SMART CITIES Objective1.1: Smart Urban digital services
Creating Efficient HVAC Systems
Creating Efficient HVAC Systems Heating and Cooling Fundamentals for Commercial Buildings Heating, ventilating, and air conditioning (HVAC) systems account for nearly half of the energy used in a typical
Diego Ibarra Christoph Reinhart Harvard Graduate School of Design
Building Performance Simulation for Designers - Energy DesignBuilder // EnergyPlus Tutorial #2 Load Schedules GEOMETRY LOADS RESULTS Diego Ibarra Christoph Reinhart Harvard Graduate School of Design OVERVIEW
International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS
International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES
Market Potential Study for Water Heater Demand Management
Market Potential Study for Water Heater Demand Management Rebecca Farrell Troutfetter, Frontier Associates LLC, Austin, TX INTRODUCTION Water heating represents between 13 and 17 percent of residential
HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY
HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY Benson Kwong, CVS, PE, CEM, LEED AP, CCE envergie consulting, LLC Biography Benson Kwong is an independent consultant providing
Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics
Carnegie Mellon University School of Architecture, Department of Mechanical Engineering Center for Building Performance and Diagnostics A Presentation of Work in Progress 4 October 2006 in the Intelligent
Glossary of HVAC Terms
Glossary of HVAC Terms Heating, Ventilation and Air Conditioning (HVAC) is a major sub- discipline of mechanical engineering. The goal of HVAC design is to balance indoor environmental comfort with other
A Roof Integrated Solar Heating System Without Storage
M. and W. Saman Sustainable Energy Centre University of South Australia Mawson Lakes Boulevard, Mawson Lakes, SA 5095, Australia E-mail: [email protected] Abstract A prototype of a roof integrated
RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary
RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary January 2013 TABLE OF CONTENTS INTRODUCTION... 3 GENERAL RECOMMENDATIONS... 3 Communication with customers in the field of environmental sustainability...
ENERGY SAVING BY COOPERATIVE OPERATION BETWEEN DISTRICT HEATING AND COOLING PLANT AND BUILDING HVAC SYSTEM
Proceedings of Building Simulation 211: ENERGY SAVING BY COOPERATIVE OPERATION BETWEEN DISTRICT HEATING AND COOLING PLANT AND BUILDING HVAC SYSTEM Yoshitaka Uno 1, Shinya Nagae 1, Yoshiyuki Shimoda 1 1
TIPS ON ENERGY SAVING
TIPS ON ENERGY SAVING IN HOME APPLIANCES AND ELECTRICITY SAFETY The Domestic Sector accounts for 30% of total energy consumption in the country. There is a tremendous scope to conserve energy by adopting
HVAC Systems: Overview
HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct
CHAPTER 10: APPLIANCES AND LIGHTING
Chapter 10: Appliances and Lighting 151 CHAPTER 10: APPLIANCES AND LIGHTING According to the U.S. Environmental Protection Agency, appliances and home electronics account for 20% of energy bills in the
Subtropical Cities September 2006. Design for Energy Efficiency in Commercial Buildings in Queensland
Subtropical Cities September 2006 Design for Energy Efficiency in Commercial Buildings in Queensland Contents Typical Building Constraints & Requirements Understanding Energy Consumption in Buildings HVAC
ICE THERMAL STORAGE IN AIR CONDITIONING APPLICATION FUNDAMENTALS
ICE THERMAL STORAGE IN AIR CONDITIONING APPLICATION FUNDAMENTALS By: T. S. Wan Date: April 19, 1994 (1st draft 3/7/86) Copyright 1994 by T. S. Wan (All rights reserved) ABSTRACT: The technology of energy
Residential HVAC Load Sizing Training October 14, 2015. David Kaiser Green Code Plan Reviewer
Residential HVAC Load Sizing Training October 14, 2015 David Kaiser Green Code Plan Reviewer DCRA - Green Building Division Regulations of green codes including: Green Building Act Green Construction Code
Selection Tips For Air-Conditioning Cooling Systems
PDHonline Course M117 (2 PDH) Selection Tips For -Conditioning Cooling Systems Instructor: A. Bhatia, B.E. 2012 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088
BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad
BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad PLEASE MARK TICK ON LEFT BOX WHICH EQUIPMENT YOU HAVE QUOTED PROPOSAL BASED ON CHINESE EQUIPMENT
RESEARCH HIGHLIGHT. The Impact of Heat Pump Water Heaters on Whole-House Energy Consumption
RESEARCH HIGHLIGHT December 2014 Technical Series 14-104 The Impact of Heat Pump Water Heaters on Whole-House Energy Consumption INTRODUCTION Heat pump water heaters are one of the most energyefficient
SIMULATION OF RADIANT COOLING PERFORMANCE WITH
SUMMARY REPORT MAY 2008 SIMULATION OF RADIANT COOLING PERFORMANCE WITH EVAPORATIVE COOLING SOURCES Timothy Moore Center for the Built Environment (CBE) University of California, Berkeley May 2008 EXECUTIVE
How To Save Money On Energy
Business Programs and Services At our Delray location, we had an immediate 23 percent drop in lighting kilowatt-hour usage. That has a significant impact on our energy bills. Ken Infante, AutoNation, Inc.
Q1 2011 Utility Rebate Report. Houston, TX
Q1 2011 Utility Rebate Report A service of the Sustainable Corporate Real Estate Roundtable Houston, TX April 7, 2011 (Captures regulations through March 31, 2011) This Report is one of a series of reports
Section 2: Estimating Energy Savings and Incentives
Section 2: Estimating Energy Savings and Incentives 2.1 Estimating Energy Savings and Incentives... 2 2.2 Customized Measures - Estimation Software... 2 2.2.1 AC&R I - High Efficiency Chiller... 3 2.2.2
Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump
Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump The basics... This guide can help you make an informed
Energy'Saving,'Thermal'Comfort'and'Solar'Power'Information'Sheet'
Energy'Saving,'Thermal'Comfort'and'Solar'Power'Information'Sheet' We ve prepared this information sheet to help you to minimise energy consumption and energy costs while maximising thermal comfort at home.
Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany
Life Cycle Costing Analysis of Water-cooled Chillers Chillventa Nuremburg, Germany Spring 2012 Description Life Cycle Cost Analysis is a method of determining and comparing the total costs of investment
Codes and High Performance Hot Water Systems. Gary Klein Affiliated International Management, LLC 916 549 7080 gary@aim4sustainability.
Codes and High Performance Hot Water Systems Gary Klein Affiliated International Management, LLC 916 549 7080 [email protected] Annual Energy Use for Heating Water Natural Gas Gallons Per Day
SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP
research journal 2013 / VOL 05.01 www.perkinswill.com SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP ARCHITECTURE AND ENGINEERING OF SUSTAINABLE BUILDINGS Current Trends in Low-Energy HVAC Design
Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia
Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia Prepared for the U.S. Department of Energy s Federal Energy Management Program
Xcel Business Customers: Program and Rebate Summary
Xcel Business Customers: Program and Rebate Summary Rebates for New Energy-Efficient Equipment Xcel offers prescriptive rebates to its business customers. What s a prescriptive rebate? It simply means
How To Design A Building In New Delhi
ENERGY EFFICIENT HVAC DESIGN FOR COMPOSITE CLIMATE Overview of Design Conditions: Air conditioning system consumes most of the energy that a building needs in its operation. In order to reduce energy consumption
THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT.
THE NATIONAL BUILDING REGULATIONS PART XA: ENERGY EFFICIENCY. Presentation by Peter Henshall-Howard: HEAD: BUILDING DEVELOPMENT MANAGEMENT. A Diagrammatic representation of the relationship between the
Heating, Ventilation & Air Conditioning Equipment
FinAnswer Express Wyoming Incentive Catalog Effective as of October 1, 2011 Heating, Ventilation & Air Conditioning Equipment Rocky Mountain Power provides incentives for many types of energy efficient
Example of audit of an air conditioning system
Example of audit of an air conditioning system Authors and affiliations: André Philippe Hannay Cleide, Hannay Jules, Lebrun Jean University of Liège, Belgium Main author: Jean Lebrun Email : [email protected]
The Chilled Water and Hot Water Building Deferential Pressure Setpoint Calculation Chilled Water and Hot Water Pump Speed Control
The Chilled Water and Hot Water Building Deferential Pressure Setpoint Calculation Chilled Water and Hot Water Pump Speed Control Chenggang Liu Research Associate Homer L. Bruner, Jr., CEM Mechanical Systems
COMPARATIVE LIFE-CYCLE ANALYSIS OF ENERGY-EFFICIENCY MEASURES AT TVA S CHATTANOOGA OFFICE COMPLEX: PHASE II RESULTS & FINAL DESIGN
COMPARATIVE LIFE-CYCLE ANALYSIS OF ENERGY-EFFICIENCY MEASURES AT TVA S CHATTANOOGA OFFICE COMPLEX: PHASE II RESULTS & FINAL DESIGN Umesh Atre Innovative Design Inc 850 W Morgan St Raleigh, NC 27603 [email protected]
RosevilleProject. LoE _ 2 Glass Products. You can reduce your cooling energy usage by 25% or more. Here is the proof.
RosevilleProject Glass Products You can reduce your cooling energy usage by 25% or more. Here is the proof. Hot-Button Issues Residents of California, Arizona, and Nevada don t need a weather forecast
Robert J. Hughes Manager Product Marketing Georgia Power Atlanta, GA, USA. (c) 2009 Georgia Power
Robert J. Hughes Manager Product Marketing Georgia Power Atlanta, GA, USA Georgia Power s Critical Peak Pricing pilot program PoweRewards March 22 25, 2009 Miami, FL, USA What are we trying to accomplish?
Corporate Energy Conservation & Demand Management Plan (CECDMP) 2014-2019
Corporate Energy Conservation & Demand Management Plan (CECDMP) 2014-2019 Table of Contents Our Commitment to Energy Conservation...1 1.0 Introduction...2 2.0 Energy Supply in Ontario...3 2.1 Energy Supply
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
Case Studies: Infrared Heating in Industrial Applications
Case Studies: Infrared Heating in Industrial Applications Chao Chen, Puget Sound Energy ABSTRACT Puget Sound Energy (PSE) is a utility which serves more than one million electric customers and over 700,000
Commercial/Office Space
C A S E S T U D I E S Commercial/Office Space Newmark Knight Frank Making -Efficiency Their Standard Orange Health Care Center Gets an -Efficiency Check-up 1 Long Wharf Drive in New Haven owned by Newmark
Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis
Components HVAC General System Selection Life Cycle Cost Analysis Outdoor Air Design Values Indoor Air Design Values Outdoor Air Ventilation Welding Ventilation Temperature Control Systems Ductwork HVAC
Schedule OLM-AS OPTIONAL LOAD MANAGEMENT AND AUTOMATION SERVICES RIDER
NEVADA POWER COMPANY dba NV Energy -0001 cancels 3rd Revised PUCN Sheet No. 11G Tariff No. 1-A (withdrawn) Cancelling 2nd Revised PUCN Sheet No. 11G APPLICABLE This Rider ( Rider ) is applicable to Customers
Heating, ventilation and air conditioning equipment. A guide to equipment eligible for Enhanced Capital Allowances
Heating, ventilation and air conditioning equipment A guide to equipment eligible for Enhanced Capital Allowances 2 Contents Introduction 03 Background 03 Setting the scene 03 Benefits of purchasing ETL
ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM
ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM J.S. Hu, Philip C.W. Kwong, and Christopher Y.H. Chao Department of Mechanical Engineering, The Hong Kong University of Science and Technology Clear Water Bay,
Study on Performance Evaluation of a Split Air Conditioning System Under the Actual Conditions
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 Study on Performance Evaluation of a Split Air Conditioning System Under
Comparing Energy Savings of Different VAV Systems
Comparing Energy Savings of Different VAV Systems Prepared By: Martyn Dodd [email protected] EnergySoft LLC 1025 5th Street, Suite A Novato, CA 94945 415-897-6400 www.energysoft.com Last Modified: March
Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems
Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems If you're a designer or a BCA, this guidance on the energy efficiency of HVAC systems in commercial buildings may
The sample report format is applicable to many different building types and systems and the examples provided cover a variety of applications.
Purpose Power Smart s Minimum Requirements for an Energy Study (see Appendix) provides a comprehensive list of the basic elements which must be included in an Energy Study Report. The intent of this sample
Energy Saving Tips. Adjust set point temperature up a few degrees... Window contact. Occupancy sensor. A Programmable Thermostat
Energy Saving Tips Nowadays when Energy costs are skyrocketing and the awareness to environmental issues is increasing, we all want to reduce energy consumption and have a greener lifestyle. Heating &
The Sino-Italy Environment & Energy Building (SIEEB): A model for a new generation of sustainable buildings
International Conference Passive and Low Energy Cooling 935 for the Built Environment, May 25, Santorini, Greece The Sino-Italy Environment & Energy Building (SIEEB): A model for a new generation of sustainable
CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION
CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION 3.1 Purpose of Thermal Load Estimation 3.2 Heating Load versus Cooling Load 3.3 Critical Conditions for Design 3.4 Manual versus Computer Calculations 3.5 Heating
Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment
Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment The heating, ventilation and cooling loads of typical commercial office space can range
A Cover HVAC ENERGY EFFICIENT
A Cover HVAC ENERGY EFFICIENT EQUIPMENT toolkit 1 CONTENTS AND PARTNERS 2 Introduction 3 equipment & processes 3 Optimise operating settings 2 upgrade equipment 4 Seal the building 5 Rearrange air conditioning
Yijun Gao, Wei Wu, Zongwei Han, Xianting Li *
Study on the performance of air conditioning system combining heat pipe and vapor compression based on ground source energy-bus for commercial buildings in north China Yijun Gao, Wei Wu, Zongwei Han, Xianting
The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.
MSV: Square Footage: 24,844 No. of Floors: 1 Year Built: 1963 Type of Use: Lounge and dining area open all night for snacks Steam Water-cooled condenser, 50-Ton York unit with a 6 cylinder-reciprocating
IDEA Presentation SMALL CAMPUS CHILLED WATER PLANT OPTIMIZATION.
IDEA Presentation SMALL CAMPUS CHILLED WATER PLANT OPTIMIZATION. Pre-Project Details Hawaiian Community College Campus consisting of 16 individual buildings totaling 308,000 sq.ft of conditioned space.
Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks
Presentation Outline Common Terms / Concepts HVAC Building Blocks Plant Level Building Blocks Description / Application Data Green opportunities Selection Criteria Air Distribution Building Blocks same
ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE
ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE Overview of Design Conditions: Air conditioning system consumes most of the energy that a building needs in its operation. In order to reduce
Center for Energy Education Laboratory
Paper ID #7072 Center for Energy Education Laboratory Dr. Robert Gilbert, Sinclair Community College Robert B. Gilbert, Ph.D., LEED AP, BA, is an Associate Professor of Energy Management Technology, and
PARTNERING. in Energy. Solutions A PROGRAM TO PROMOTE BUSINESS ENERGY EFFICIENCY
PARTNERING in Energy Solutions A PROGRAM TO PROMOTE BUSINESS ENERGY EFFICIENCY Partnering in Energy Solutions Business Customers 3 Owatonna Public Utilities An Energy PARTNER for our Customers How can
Greenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings
Greenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings J A NUARY 2015 INTRODUCTION This Research Report explores best practices and approaches for reducing greenhouse gas (GHG)
Comparison between Decentralised and Centralised Air Conditioning Systems
Comparison between De and Centralised Air Conditioning Systems (Summary) FassadenSystemLüftung FassadenSystemLüftung Telephone +49/ 28 45/ 2 02-711 GmbH & Co KG Telefax +49/28 45/2 02-2 25 Heinrich-Trox-Platz
Training for Building Technicians: Energy Efficiency & Sustainability (BEST) Program. Seminar Outline & Sample BEST Exam Questions
Training for Building Technicians: Energy Efficiency & Sustainability (BEST) Program Seminar Outline & Sample BEST Exam Questions Buildings in the United State consume a significant amount of energy. According
Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools
Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL
Acumen Enterprises, Inc.
Hourly rates Discount w/o Rebate Electrician $78.00 10% $70.20 $70.73 HVAC Technician $78.00 10% $70.20 $70.73 Insulator $42.00 10% $37.80 $38.08 Sheet Metal Worker $74.00 10% $66.60 $67.10 Plumber/Pipefitter
HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget
A PRIMER Educational HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget Contents: Introduction: The best HVAC system is durable, reliable
Second Place: Industrial Facilities or Processes, New
Second Place: Industrial Facilities or Processes, New Photo: Paul Howell Texas Medical Center in Houston is the largest medical center in North America. It has a chilled water system of 160,000 tons. Big
Council s energy efficiency upgrades benefit community
Council s energy efficiency upgrades benefit community Project Snapshot Objective: reduce energy, save money & improve comfort in public buildings Where: Meander Valley Council, Northern Tasmania Total
The natural ombination
The natural ombination DAikin Altherma Hybrid heat pump system The future is now The new hybrid system Heat pump solution for gas boiler replacement market Daikin Altherma hybrid combines heat pump technology
Tips on Saving Energy in Your Business
Fact Sheet #3 Tips on Saving Energy in Your Business In this fact sheet you will discover: Quick and easy changes to save energy. Cost effective ways to reduce your heating, cooling, lighting and office
Air Conditioning Contractors of America
Air Conditioning Contractors of America WHO IS ACCA???? Industry Manuals Residential D, J, S, H, RS, T, P A manual J load calculation is a measurement of how much heating and cooling capacity a home will
How to choose a heat pump and use it wisely
How to choose a heat pump and use it wisely Contents How does a heat pump work? 2 Insulating your home 3 Heat loss in the home Not all heat pumps are created equal 4 Choosing a heat pump 4 Choosing by
Building HVAC Load Profiling Using EnergyPlus
Building HVAC Load Profiling Using EnergyPlus Dong Wang School of EEE Nanyang Technological University Singapore Email: [email protected] Abhisek Ukil, Senior Member, IEEE School of EEE Nanyang Technological
Mechanical, Plumbing, and Fire Protection Conditions
Mechanical, Plumbing, and Fire Protection Conditions Mechanical Conditions The mechanical systems within the building consist of a combination of the original 1926 systems and renovations that occurred
Typical Cooling Load Profile
Ice Storage Systems and Impact on Electric Demand Georges Hoeterickx Specialists in Heat Transfer Products and Services 1 2 Cooling Load Typical Cooling Load Profile 0 2 4 6 8 10 12 14 16 18 20 22 Time
imagine SOLAR AIR CONDITIONING MADE EASY
imagine SOLAR AIR CONDITIONING MADE EASY WHY SOLAR COOLING? Imagine...being able to fit a solar air conditioning system to your building that would result in dramatic reductions in electricity consumption
Heating, ventilation and air conditioning (HVAC) equipment. A guide to equipment eligible for Enhanced Capital Allowances
Heating, ventilation and air conditioning (HVAC) equipment A guide to equipment eligible for Enhanced Capital Allowances 2 Contents Boost Introduction your cash flow 03 1. Background Check it s on the
Energy Efficiency Opportunities in Federal High Performance Computing Data Centers
Energy Efficiency Opportunities in Federal High Performance Computing Data Centers Prepared for the U.S. Department of Energy Federal Energy Management Program By Lawrence Berkeley National Laboratory