Cisco UCS C460 M4 High-Performance Rack-Mount Server
|
|
- Ashley Morgan
- 8 years ago
- Views:
Transcription
1 Spec Sheet Cisco UCS C460 M4 High-Performance Rack-Mount Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, REV A.16 AUGUST 13,
2 CONTENTS OVERVIEW DETAILED VIEWS Chassis Front View Chassis Rear View BASE SERVER STANDARD CAPABILITIES and FEATURES CONFIGURING the SERVER STEP 1 VERIFY BASE SKU STEP 2 CHOOSE CPU(S) STEP 3 CHOOSE MEMORY STEP 4 CHOOSE HARD DISK DRIVEs or SOLID STATE DRIVEs STEP 5 CHOOSE RAID CONFIGURATION STEP 6 CHOOSE PCIe OPTION CARD(S) STEP 7 CHOOSE PCIe RISERS STEP 8 ORDER OPTIONAL NETWORK CARD ACCESSORIES STEP 9 ORDER GPU CARDS and ACCESSORIES (OPTIONAL) STEP 10 ORDER POWER SUPPLIES STEP 11 SELECT AC POWER CORD(s) STEP 12 ORDER OPTIONAL SLIDE RAIL KIT STEP 13 ORDER OPTIONAL CABLE MANAGEMENT ARM STEP 14 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL) STEP 15 ORDER A TRUSTED PLATFORM MODULE STEP 16 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARE STEP 17 CHOOSE OPERATING SYSTEM MEDIA KIT STEP 18 CHOOSE SERVICE and SUPPORT LEVEL OPTIONAL STEP - ORDER RACKS OPTIONAL STEP - ORDER PDU SUPPLEMENTAL MATERIAL CHASSIS CPUs and DIMMs Physical Layout Memory Population Rules Memory Population Order RACKS PDUs KVM CABLE TECHNICAL SPECIFICATIONS Dimensions and Weight Power Specifications Environmental Specifications Compliance Requirements
3 OVERVIEW OVERVIEW The Cisco UCS C460 M4 High-Performance Rack Server (Figure 1) is a four-rack-unit (4RU) server supporting the Intel Xeon E v2 and E v2 series processor family CPUs, with up to 6 terabytes (TB) of double-data-rate 3 (DDR3) memory 1 in 96 slots, and up to 12 small form factor (SFF), hot-swappable 2 SAS and SATA disk drives. 10 PCI Express (PCIe) slots support the Cisco UCS C-Series network adapters, with additional I/O provided by 2 Gigabit Ethernet LOM ports, 2 10-Gigabit Ethernet ports, and one dedicated out-of-band (OOB) management port. A separate PCIe slot is reserved inside the chassis for a RAID controller card. Figure 1 Cisco UCS C460 M4 High-Density Rack Server Front View Rear View Notes A maximum of 6 TB memory is available using 64 GB DIMMs, when available. 2. Hot-swap replacement means that you do not have to precondition or shut down the component in software before you remove it. 3
4 DETAILED VIEWS DETAILED VIEWS Chassis Front View Figure 2 is a detailed front view of the Cisco UCS C460 M4 General-Purpose Rack Server. Figure 2 Chassis Front View FAN 1 FAN 2 FAN 3 FAN 4 HDD 01 HDD 05 HDD 09 HDD 02 HDD 06 HDD 10 HDD 03 HDD 07 HDD 11 HDD 04 HDD 08 HDD Cooling fans (hot-swappable and accessible from the front panel) 7 Temperature status LED 2 Operations panel 8 Power supply status LED 3 Power button/led 9 Network link activity LED 4 Identification button/led 10 SAS/SATA drive bays 1 12 (hot-swappable) 5 System status LED 11 KVM console connector (used with a KVM cable that provides two USBs, one VGA, and one serial connector) 1 6 Fan status LED 12 Pull-out asset tag Notes For more details on the KVM connector, see KVM CABLE on page 64. 4
5 DETAILED VIEWS Chassis Rear View Figure 3 shows the external features of the rear panel. Figure 3 Chassis Rear View 2 1 PCIe 6 PCIe 7 PCIe 1 PCIe 2 PSU 1 PCIe 8 PCIe 9 Riser 2 PCIe 3 PCIe 4 Riser 1 PSU 2 PCIe 10 PCIe 5 PSU 3 PSU PCIe riser 1 (slots 1 5) 6 10 Gb Ethernet ports (two) 2 PCIe riser 2 (slots 6 10) 7 USB 2.0 ports (three) 3 Serial port (DB-9 connector) 8 1 Gb Ethernet ports (two) 4 VGA video port (DB-15 connector) 9 Rear identification LED 5 10/100/1000 Ethernet dedicated management port M1 10 Power supplies 1 4 (hot-swappable, redundant as 2+2) 5
6 BASE SERVER STANDARD CAPABILITIES and FEATURES BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 lists the capabilities and features of the base server. Details about how to configure the server for a particular feature or capability (for example, number of processors, disk drives, or amount of memory) are provided in CONFIGURING the SERVER on page 9. Table 1 Capabilities and Features Capability/Feature Chassis CPU InfiniBand Chipset Memory Expansion slots Description Four rack unit (4RU) chassis Either 2 or 4 Intel Xeon E v2 or E v2 series processor family CPUs Four power supplies are required for both 2-CPU and 4-CPU configurations. The bus slots in this server support the InfiniBand architecture. Intel C602J chipset Eight motherboard slots for memory riser boards. Each memory riser can hold up to 12 DIMMs, for a maximum DIMM population of 96 DIMMs. Each CPU can control 2 memory risers (up to 24 DIMMs). Memory risers are hot-pluggable 1. Maximum memory capacity is 6 TB 2. This is accomplished with 96 DIMMs, consisting of 48 DIMM kits (2 64 GB matched DIMMs per kit) in a 4-CPU configuration. There are 10 full-height PCIe expansion slots: Slot 1: CPU1 controlled, Gen-3 8x, 98-pin Slot 2: CPU1 controlled, Gen-3 16x, NCSI, 230-pin Slot 3: CPU2 controlled, Gen-3 4x, NCSI, 230-pin Slot 4: CPU2 controlled, Gen-3 8x, NCSI, 230-pin Slot 5: CPU2 controlled, Gen-3 8x, NCSI, 230-pin Slot 6: CPU4 controlled, Gen-3 8x, 98-pin Slot 7: CPU3 controlled, Gen-3 16x, NCSI, 230-pin Slot 8: CPU4 controlled, Gen-3 8x, NCSI, 230-pin Slot 9: CPU3 controlled, Gen-3 16x, NCSI, 230-pin Slot 10: CPU4 controlled, Gen-3 8x, NCSI, 230-pin NOTE: CPUs must be installed as indicated to support specific slots. The CPU installation options are either CPU1 and CPU2 or CPU1, CPU2, CPU3, and CPU4. See CHOOSE PCIe OPTION CARD(S) on page 23 for more details. 6
7 BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 Capabilities and Features (continued) Capability/Feature Flexible Drive Connectors Description Twelve connectors are available from the front of the server, and flexibly support hot-pluggable drive sleds or PCIe devices, as follows: All 12 connectors support hot-plug SAS/SATA hard disk drives (HDDs) or solid-state drives (SSDs) The initial RAID controller offering supports up to 8 SFF 2.5 SAS or SATA HDDs or SSDs. A future RAID controller offering includes support for 12 drives. Storage controller Factory-configured RAID support options: LSI MegaRAID SAS 9361CV-8i controller, for support of up to 8 internal SAS or SATA drives. Supports RAID 0, 1, 5, 6, and 10. This RAID controller has an on-board 1 GB cache and chassis-mounted (remote) supercap for data cache power backup There is a dedicated PCIe slot inside the chassis for the SAS i controller RAID controller card. This RAID controller cannot control PCIe drives. Internal storage devices Up to 8 SFF 2.5 SAS or SATA HDDs or SSDs. Future support of up to 12 drives. UCS Storage Accelerators are also available. These PCIe flash storage devices plug into the rear-accessible PCIe slots and provide independent high-speed storage. Cisco Flexible Flash drive Internal USB Video The server has provision for two optional blank internal Cisco Flexible Flash drives (SD cards), on the internal media riser. The server includes one internal USB 2.0 slot on the internal media riser. The server CIMC chip includes a Matrox G200e core. The first 8 MB of memory are allocated to the video core x 1024 resolution 32-bit color depth 8 MB video memory 7
8 BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 Capabilities and Features (continued) Capability/Feature Description Interfaces Rear panel One 10/100/1000 dedicated management Ethernet ports Two 1-Gigabit ports (10/100/1000 Mbps capable). These integrated Gigabit ports support the Wake on LAN (WoL) and TCP/IP Offload Engine (TOE) standards Two 10-Gigabit Base-T Ethernet ports (1 Gbps/10 Gbps capable) One RS232 serial connector One 15-pin VGA connector Three USB 2.0 connectors Front panel One KVM connector WoL The 1-Gb Base-T Ethernet LAN ports support the wake-on-lan (WoL) standard. Power subsystem Four 1400 W power supplies are required Power supplies are hot-swappable, rear-accessible, and redundant as 2+2 NOTE: For more information about your server s power consumption, use the power calculator accessible at enter/cisco_ucs_power_calculator/ ACPI Fans Integrated management processor This server supports the advanced configuration and power interface (ACPI) 4.0 standard. Chassis: 4 fans, hot-swappable Power supply: Each of the 4 power supplies is equipped with a fan. The built-in Cisco Integrated Management Controller (CIMC) GUI or CLI interface enables you to monitor the server inventory, health, and system event logs. Notes Hot-pluggable = Software shutdown of the component is required before removing while the server is powered on. 2. With 64 GB DIMMs, when available 8
9 CONFIGURING the SERVER Follow these steps to configure the Cisco UCS C460 M4 High-Performance Rack Server: STEP 1 VERIFY BASE SKU, page 10 STEP 2 CHOOSE CPU(S), page 11 STEP 3 CHOOSE MEMORY, page 12 STEP 4 CHOOSE HARD DISK DRIVEs or SOLID STATE DRIVEs, page 19 STEP 5 CHOOSE RAID CONFIGURATION, page 21 STEP 6 CHOOSE PCIe OPTION CARD(S), page 23 STEP 7 CHOOSE PCIe RISERS, page 27 STEP 8 ORDER OPTIONAL NETWORK CARD ACCESSORIES, page 28 STEP 9 ORDER GPU CARDS and ACCESSORIES (OPTIONAL), page 32 STEP 10 ORDER POWER SUPPLIES, page 34 STEP 11 SELECT AC POWER CORD(s), page 35 STEP 12 ORDER OPTIONAL SLIDE RAIL KIT, page 37 STEP 13 ORDER OPTIONAL CABLE MANAGEMENT ARM, page 38 STEP 14 ORDER CISCO FLEXIBLE FLASH SD CARD MODULE (OPTIONAL), page 39 STEP 15 ORDER A TRUSTED PLATFORM MODULE, page 40 STEP 16 CHOOSE OPERATING SYSTEM AND VALUE-ADDED SOFTWARE, page 41 STEP 17 CHOOSE OPERATING SYSTEM MEDIA KIT, page 44 STEP 18 CHOOSE SERVICE and SUPPORT LEVEL, page 45 OPTIONAL STEP - ORDER RACKS on page 50 OPTIONAL STEP - ORDER PDU on page 51 9
10 STEP 1 VERIFY BASE SKU Verify the product ID (PID) of the base server as shown in Table 2. Table 2 PID of the Base C460 M4 Rack Server Product ID (PID) UCSC-C460-M4 Description UCS C460 M4 base chassis no CPU/DIMM/HDD/PCIe/memory risers The base server: Includes: Blanking panels for empty drive locations (to maintain cooling air flow) Rail kit Does not include: CPUs DIMMs Memory risers Power supplies Hard disk drives (HDDs) Solid-state Drives (SSDs) Plug-in PCIe cards PCIe risers NOTE: Use the steps on the following pages to configure the server with the components that you want to include. 10
11 STEP 2 CHOOSE CPU(S) The standard CPU features are: Intel Xeon E v2 or E v2 (Ivy Bridge EX) series processor family CPUs Intel C602J chipset Cache size of up to 37.5 MB Choose CPUs The available CPUs are listed in Table 3. Table 3 Available CPUs: Intel Xeon E v2/e v2 Family Product ID (PID) Intel Number Clock Freq (GHz) Power (W) Cache Size (MB) Cores QPI (GT/s) Highest DDR3 DIMM Clock Support (MHz) UCS-CPU-E74809B E v UCS-CPU-E74820B E v UCS-CPU-E74830B E v UCS-CPU-E74850B E v UCS-CPU-E74860B E v UCS-CPU-E74870B E v UCS-CPU-E74880B E v UCS-CPU-E74890B E v UCS-CPU-E78880LB E7-8880L v UCS-CPU-E78857B E v UCS-CPU-E78891B E v UCS-CPU-E78893B E v Approved Configurations (1) Two-CPU Configuration Choose two identical CPUs from Table 3. (2) Four-CPU Configuration Choose four identical CPUs from Table 3. Caveats You must select either two or four identical processors. 11
12 STEP 3 CHOOSE MEMORY The standard memory features are: Plug-In Memory Riser Boards DIMMs Up to 12 DIMMs per riser board Riser boards plug vertically into the motherboard Four riser boards for 2-CPU option Eight riser boards for 4-CPU option Clock speed: 1600 or 1333 MHz Ranks per DIMM: 2, 4, or 8 Operational voltage: 1.5 or 1.35 V Registered DIMM (RDIMM) or load-reduced registered DIMM (LRDIMM) Each CPU controls four serial memory interface 2 (SMI-2) channels. Memory buffers on the memory risers convert each SMI channel into two DDR3 subchannels. There are two memory risers for each CPU. Memory is organized as three DIMMs per subchannel, as shown in Figure 4. 12
13 Figure 4 C460 M4 Memory Organization 13
14 Choose Memory Riser Boards You may choose riser boards as follows: Four memory riser boards for a two-cpu system, or Eight memory riser boards for a four-cpu system. Table 4 Available Memory Riser Boards Product ID (PID) PID Description Max DIMMs per Riser Riser Board Options UCSC-MRBD-12 Memory riser board with 12 DIMM slots 12 Approved Configurations (1) Two-CPU System Choose four memory riser boards from Table 4. (1) Four-CPU System Choose eight memory riser boards from Table 4. Caveats You should order enough risers with enough sockets to accommodate your maximum forseeable memory needs. Choose DIMMs and Memory Mirroring Select the memory configuration and whether or not you want the memory mirroring option. The available memory DIMMs and mirroring option are listed in Table 5. NOTE: When memory mirroring is enabled, the memory subsystem simultaneously writes identical data to two channels. If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error, the system automatically retrieves the data from the other channel. A transient or soft error in one channel does not affect the mirrored data, and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored DIMM. Memory mirroring reduces the amount of memory available to the operating system by 50% because only one of the two populated channels provides data. 14
15 DIMMs are orderable as kits, with two DIMMs per kit. Choose the desired number of DIMMs and the memory mirroring option if desired. The available memory DIMMs are listed in Table 5. Table 5 Available DDR3 DIMMs and DIMM Kits (2 DIMMs per kit) Product ID (PID) PID Description Voltage (V) Ranks/ DIMM DIMM Options UCS-ML-2X648RY-E 2x64GB 1 DDR MHz LRDIMM/PC-10600/octal rank 1.35v 1.5/ UCS-MR-2X162RY-E 2X16GB DDR MHz RDIMM/PC-12800/dual rank 1.35v 1.5/ UCS-ML-2X324RY-E 2x32GB DDR MHz LRDIMM/PC-12800/quad rank 1.35v 1.5/ UCS-MR-2X082RY-E 2X8GB DDR MHz RDIMM/PC-12800/dual rank 1.35v 1.5/ Memory Mirroring Option N01-MMIRROR Memory mirroring option Notes Systems with 64 GB DIMMs are limited to a maximum ambient temperature of 32 C (89.6 F). In addition, systems with 64 GB DIMMs cannot implement any GPUs. Approved Configurations (1) Minimum Configuration without memory mirroring One memory riser with at least one matched DIMM pair. The memory riser must be installed in a slot controlled by either CPU1 or CPU2. All four CPUs can run from a single DIMM pair. (2) Maximum Configuration without memory mirroring Eight memory risers with at least one matched DIMM pair per riser (16 DIMMs total) and up to six matched DIMM pairs per riser (96 DIMMs total). (3) Minimum Configuration with memory mirroring One memory riser with at least two matched DIMM pairs. (4) Maximum Configuration with memory mirroring 15
16 Eight memory risers with at least two matched DIMM pairs per riser (16 DIMMs total) and up to six matched DIMM pairs per riser (96 DIMMs total). NOTE: There are three memory mirroring modes: 1 Intra-socket mirroring 2 Inter-socket cross-memory-controller mirroring 3 Inter-socket complete master-slave mirroring Mirroring mode can be configured using the UCS Manager BIOS Policy RAS Memory tab. Available DIMM Configurations See Table 6 for the possible DIMM configurations in 2-CPU and 4-CPU systems. Table 6 Available DIMM Configurations Desired DIMMs per CPU 2-CPU System 4-CPU System DIMM Kit Qty Total DIMMs DIMM Kit Qty Total DIMMs (see Table 5 on page 15) (see Table 5 on page 15) Caveats Memory Mode. System speed is dependent on how many DIMMs are populated per channel, the CPU DIMM speed support, and the BIOS memory mode. The BIOS default memory mode is performance mode. However, the BIOS can be changed to support lockstep mode. 16
17 Memory Performance Mode. In this mode, the main memory channel from the CPU to the memory buffer runs at double the clock rate of each of the two memory subchannels from the buffer to the DIMMs, and each DIMM subchannel is accessed sequentially. For example, if the CPU channel clock speed is 2667 MHz, each of the DIMM subchannels operates at 1333 MHz. For this reason, performance mode is referred to as 2:1. Performance mode does not provide data protection, but can yield up to 1.5 times the performance of lockstep mode and is the best choice for high throughput requirements. Memory Lockstep Mode. In this mode, the main memory channel from the CPU to the memory buffer runs at the same clock rate of each of the two memory subchannels from the buffer to the DIMMs, and both DIMM subchannels are accessed simultaneously for a double-width access. For example, if the CPU channel clock speed is 1600 MHz, each of the DIMM subchannels operates at 1600 MHz. For this reason, lockstep mode is referred to as 1:1. Memory lockstep mode provides protection against both single-bit and multi-bit errors. Memory lockstep lets two memory channels work as a single channel, moving a data word two channels wide and providing eight bits of memory correction. CPU Effect on DIMM Performance Table 7 CPU Effect on DIMM Performance CPU Memory Mode Advanced CPU GT/s QPI Standard CPU GT/s QPI Basic CPU GT/s QPI Lockstep Mode (1:1) 1600 MHz 1600 MHz 1333 MHz Performance Mode (2:1) 1333 MHz 1066 MHz 1066 MHz Notes CPU examples: E7-4890/4880/4870/4860 v2, E7-8893/8891/8857 v2 2. CPU examples: E7-4850/4830/4820 v2 3. CPU example: E v2 DIMM Clock Speeds DIMMs run at various clock speeds depending on the DIMM voltage and number of DIMMs per channel. See Table 8 and Table 9. Table 8 DIMM Performance (at 1.5 V) DIMM GB/Rank/Type Performance Mode (2:1) 1.5 V DIMM Lockstep Mode (1:1) 1.5 V DIMM 1 DPC 2 DPC 3 DPC 1 DPC 2 DPC 3 DPC 8 GB/2R/RDIMM 1333 MHz 1333 MHz 1066 MHz 1333 MHz 1333 MHz 1066 MHz 16 GB/2R/RDIMM 1333 MHz 1333 MHz 1066 MHz 1333 MHz 1333 MHz 1066 MHz 32 GB/4R/LRDIMM 1333 MHz 1333 MHz 1333 MHz 1600 MHz 1600 MHz 1333 MHz 17
18 Table 9 DIMM Performance (at 1.35 V) DIMM GB/Rank/Type Performance Mode (2:1) 1.35 V DIMM Lockstep Mode (1:1) 1.35 V DIMM 1 DPC 2 DPC 3 DPC 1 DPC 2 DPC 3 DPC 8 GB/2R/RDIMM 1333 MHz 1066 MHz N/A 1333 MHz 1066 MHz N/A 16 GB/2R/RDIMM 1333 MHz 1066 MHz N/A 1333 MHz 1066 MHz N/A 32 GB/4R/LRDIMM 1333 MHz 1333 MHz N/A 1333 MHz 1333 MHz N/A The minimum DIMM configuration is at least one matched DIMM pair installed in a memory riser on either CPU1 or CPU2. All four CPUs can run from a single DIMM pair. DIMMs are required to be populated in pairs. DIMMs for this server are available as two-dimm kits. The DIMMs in any given pair must be identical. Any DIMM installed in a memory riser corresponding to an empty CPU slot becomes inaccessible. For optimal performance, distribute DIMMs evenly across all installed CPUs and memory buffers. Do not mix RDIMMs and LRDIMMs. DIMMs within a channel are populated starting with the DIMMs farthest from the memory buffer in a fill-farthest approach. Matched pairs of risers on paired DDR3 channels must have identical DIMM configurations. If any GPU is installed, the maximum amount of DIMM memory allowed in the server is 1 TB (for example, 32x32 GB DIMMs or 64x16 GB DIMMs). If a system uses 64 GB DIMMs, the maximum ambient temperature is 32 C (89.6 F). In addition, systems with 64 GB DIMMs cannot implement any GPUs. For more information about memory, see CPUs and DIMMs on page
19 STEP 4 CHOOSE HARD DISK DRIVEs or SOLID STATE DRIVEs The standard disk drive features are: 2.5-inch small form factor Hot-swappable Sled-mounted Choose Drives The available drives are listed in Table 10. Table 10 Available Hot-Pluggable Sled-Mounted HDDs and SSDs Product ID (PID) PID Description Drive Type Capacity HDDs UCS-HD600G15KS2-E 600 GB SAS 15K RPM SFF HDD SAS 600 GB UCS-HD450G15KS2-E 450 GB SAS 15K RPM SFF HDD SAS 450 GB UCS-HD12T10KS2-E 1.2 TB 6 Gb SAS 10K RPM SFF HDD SAS 1.2 TB UCS-HD1T7KS2-E 1 TB SAS 7.2K RPM SFF HDD SAS 1.0 TB UCS-HDD900GI2F GB 6 Gb SAS 10K RPM SFF HDD SAS 900 GB A03-D600GA2 600 GB 6 Gb SAS 10K RPM SFF HDD SAS 600 GB UCS-HDD300GI2F GB 6 Gb SAS 15K RPM SFF HDD SAS 300 GB A03-D300GA2 300 GB 6 Gb SAS 10K RPM SFF HDD SAS 300 GB SSDs UCS-SD16T12S2-EP 1.6 TB 12 Gb SAS 2.5 inch Enterprise performance SSD SAS 1.6 TB UCS-SD800G0KS2-EP 800 GB SAS 2.5 inch Enterprise Performance SSD SAS 800 GB UCS-SD400G12S2-EP 400 GB 12 Gb SAS 2.5 inch Enterprise performance SSD SAS 400 GB UCS-SD400G0KS2-EP 400 GB SAS 2.5 inch Enterprise Performance SSD SAS 400 GB UCS-SD400G0KA2-G 400 GB SATA 2.5 inch Enterprise Value SSD SATA 400 GB UCS-SD200G0KS2-EP 200 GB SAS 2.5 inch Enterprise Performance SSD SAS 200 GB UCS-SD100G0KA2-G 100 GB SATA 2.5 inch Enterprise Value SSD SATA 100 GB 19
20 Approved Configurations (1) LSI MegaRAID SAS 9361CV-8i RAID controller Select up to 8 SAS or SATA internal drives listed in Table 10. You can mix SAS/SATA drives. You can also mix HDD and SSD drives, as long as all the HDDs are in the same RAID volume and all the SSDs are in the same RAID volume. This configuration supports RAID 0, 1, 5, 6, and 10. Caveats SSDs and HDDs should not be mixed in the same RAID volume. 20
21 STEP 5 CHOOSE RAID CONFIGURATION The C460 M4 server accommodates the LSI MegaRAID SAS 9361CV-8i for internal drives. The C460 M4 chassis contains a front drive bay housing up to 12 HDDs or SSDs. Cisco can provide factory-configured RAID 0, 1, 5, 6, and 10 systems depending on the RAID implementation chosen, the RAID controller chosen, and the number of drives ordered. Factory-configured RAID options are listed at the end of Table 11. Note that RAID levels 50 and 60 are supported on the 9361CV-8i, but are not factory configurable. Choose RAID Options Choose one internal RAID controller with a desired RAID configuration option from Table 11. Table 11 Available RAID Options Product ID (PID) RAID Controllers UCS-RAID9361CV-8I RAID Configuration R2XX-RAID0 R2XX-RAID1 R2XX-RAID5 R2XX-RAID6 R2XX-RAID10 PID Description LSI MegaRAID SAS 9361CV-8i (RAID 0, 1, 5, 6, 10, 50, 60 supported) Plugs into a dedicated PCIe slot on the server motherboard (see Figure 7 on page 52). Supports from 1 to 8 internal SAS or SATA drives Includes a 1 GB Transportable Memory Module (TMM) and a chassis-mounted (remote) supercapacitor for data cache power backup Factory-configured RAID options: RAID 0, 1, 5, 6, 10 (see the RAID PIDs section in this table) Factory pre-configured RAID striping option Enable RAID 0 Setting. Requires a minimum of 1 hard drive. Factory pre-configured RAID mirroring option Enable RAID 1 Setting. Requires exactly 2 drives, with same size, speed, capacity. Factory pre-configured RAID option Enable RAID 5 Setting. Requires minimum 3 drives of same size, speed, capacity. Factory pre-configured RAID option Enable RAID 6 Setting. Requires minimum 4 drives of same size, speed, capacity. Factory pre-configured RAID option Enable RAID 10 Setting. Requires an even number of drives (minimum 4 drives) of same size, speed, capacity. 21
22 NOTE: No RAID option can be chosen if you have one of the following configurations: A mix of SAS and SATA drives No drives Approved Configurations (1) One RAID controller card for internal drives Caveats Choose the 9361CV-8i controller listed in Table 11. You will be able to control from 1 to 8 with the 9361CV-8i RAID controller. You can choose an optional RAID configuration (RAID 0, 1, 5, 6, or 10), which is pre-configured at the factory. If you do not choose a RAID configuration, the disks will be configured as a JBOD. 22
23 STEP 6 CHOOSE PCIe OPTION CARD(S) The standard PCIe card offerings are: Converged Network Adapters (CNA) Network Interface Cards (NICs) Host Bus Adapters (HBAs) UCS Storage Accelerators Choose PCIe Option Cards The available PCIe option cards are listed in Table 12. Table 12 Available PCIe Option Cards Product ID (PID) PID Description Converged Network Adapters (CNA) UCSC-PCIE-C10T-02 Cisco VIC 1225T Dual Port 10GBaseT CNA Half UCSC-PCIE-C40Q-02 Cisco VIC 1285 Dual Port 40Gb QSFP CNA Half UCSC-PCIE-CSC-02 1 Cisco VIC 1225 Dual Port 10Gb SFP+ CNA Half UCSC-PCIE-B3SFP Broadcom Gb AFEX SFP+ Half UCSC-PCIE-ESFP Emulex OCe11102-FX Dual Port 10Gb SFP+ CNA Half UCSC-PCIE-Q8362 Qlogic QLE8362 dual-port 10 GbE FCoE CNA Half Network Interface Cards (NICs) N2XX-ABPCI03-M3 Broadcom 5709 Quad Port 1Gb w/toe iscsi for M3 Servers Half N2XX-AIPCI01 Intel X520 Dual Port 10Gb SFP+ Adapter Half UCSC-PCIE-B3SFP Broadcom Gb AFEX SFP+ Half UCSC-PCIE-IRJ45 Intel i350 Quad Port 1Gb Adapter Half UCSC-PCIE-ITG 1 Intel X540 Dual Port 10GBase-T Adapter Half Host Bus Adapters (HBAs) N2XX-AEPCI03 Emulex LPe Dual Port 4Gb Fibre Channel HBA Half N2XX-AEPCI05 Emulex LPe Dual Port 8Gb Fibre Channel HBA Half UCSC-PCIE-E16002 Emulex Lpe M6, 16Gb Dual Port Fibre Channel HBA with SR Optics Half N2XX-AQPCI03 Qlogic QLE2462 Dual Port 4Gb Fibre Channel HBA Half N2XX-AQPCI05 Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA Half Card Height UCSC-PCIE-Q2672 Qlogic QLE2672-CSC, 16Gb Dual Port Fibre Channel HBA with SR Optics Half 23
24 Table 12 Available PCIe Option Cards (continued) Product ID (PID) UCS Storage Accelerators PID Description UCSC-F-FIO-1205M Cisco UCS 1205 GB MLC Fusion iodrive2 for C-Series Servers Half UCSC-F-FIO-3000M Cisco UCS 3.0 TB MLC Fusion iodrive2 for C-Series Servers Full UCSC-F-FIO-365M Cisco UCS 365GB MLC Fusion iodrive2 for C-Series Servers Half UCSC-F-FIO-785M Cisco UCS 785 GB MLC Fusion iodrive2 for C-Series Servers Half Notes The UCSC-PCIE-ITG and UCSC-PCIE-CSC-02 cannot be installed in the same system. Card Height Approved Configurations (1) Select up to 10 PCIe Cards Use Table 13 and Table 14 on page 25 as a guide for adding PCIe cards. See Figure 5 for the slot locations. Table 13 PCIe Expansion Slot Numbering Slot Number Slot Characteristics 1 CPU1 controlled, PCIe Gen 3, x8 lanes, full-length card, x8 connector 2 CPU1 controlled, PCIe Gen 3, x16 lanes, NCSI, full-length card, x16 connector 3 CPU2 controlled, PCIe Gen 3, x4 lanes, NCSI, 3/4-length card, x16 connector 4 1 CPU2 controlled, PCIe Gen 3, x8 lanes, NCSI, 3/4-length card, x16 connector 5 1 CPU2 controlled, PCIe Gen 3, x8 lanes, NCSI, 1/2-length card, x16 connector 6 CPU4 controlled, PCIe Gen 3, x8 lanes, full-length card, x8 connector 7 CPU3 controlled, PCIe Gen 3, x16 lanes, NCSI, full-length card, x16 connector 8 CPU4 controlled, PCIe Gen 3, x8 lanes, NCSI, 3/4-length card, x16 connector 9 1 CPU3 controlled, PCIe Gen 3, x16 lanes, NCSI, 3/4-length card, x16 connector 10 1 CPU4 controlled, PCIe Gen 3, x8 lanes, 1/2-length card, x16 connector Notes Slots 4, 5, 9 and 10 can be enabled for 12-volt VIC standby power (only one at a time). 24
25 Table 14 PCIe Expansion Slot Priorities PCIe Card Type Primary Slot (install here first) Secondary Slot (install here second) Alternate Slot (may have reduced functionality) LSI MegaRAID Card Internal RAID slot (see Figure 7 on page 52) Low-profile x8 Network Card or RAID card for external drives Slot 5 (riser 1) Slot 10 (riser 2) Slot 8 (riser 2) Slot 4 (riser 1) Slot 9 (riser 2) Slot 2 (riser 1) Slot 7 (riser 2) Slot 1 (riser 1) Slot 6 (riser 2) Slot 3 (Riser 1) VIC cards Slot 4 (Riser 1) Slot 9 (riser 2) Slot 5 (riser 1) Slot 10 (riser 2) Slot 3 (riser 1) Slot 8 (riser 2) Slot 2 (riser 1) Slot 7 (riser 2) GPU Slots 7 and 6 (riser 2) Slots 2 and 1 (riser 1) UCS Storage Accelerators Slot 5 (riser 1) Slot 10 (riser 2) Slot 8 (riser 2) Slot 4 (riser 1) Slot 7 (riser 2) Slot 2 (riser 1) Slot 6 (riser 2) Slot 1 (riser 1) Slot 10 (riser 2) Slot 3 (riser 1) 1 Notes This slot is a x4 slot, so there is some performance degradation when installing a storage accelerator in this slot. Figure 5 PCIe Slot Locations PCIe 6 PCIe 7 PCIe 1 PCIe 2 PSU 1 PCIe 8 PCIe 9 Riser 2 PCIe 3 PCIe 4 Riser 1 PSU 2 PCIe 10 PCIe 5 PSU 3 PSU 4 25
26 Caveats CPU1 and CPU2 must be installed to support PCIe slots 1 through 5. CPU2 and CPU4 must be installed to support PCIe slots 6 through 10. Legacy I/O devices such as video cards are only supported on slots 1, 2, 4, 5, 6, 7, 8, 9, and 10. The Cisco Card NIC mode is currently supported only with a Cisco VIC card that is installed in PCIe slot 4, 5, 9, or 10. The C460 M4 server accommodates the Cisco Virtual Interface card, which is supported primarily in slots 4 and 9. Only one Cisco 1225 VIC can be used for both UCSM management and data traffic in the C460 M4 server The Cisco 1225 VIC in slot 4 handles management and data traffic. If a second Cisco 1225 VIC is installed in slot 9, it will be used for data traffic only. All PCIe slots are standard-height and require a standard-height mounting bracket on the PCIe card. The UCSC-PCIE-ITG and UCSC-PCIE-CSC-02 cannot be installed in the same system. You cannot have a GPU installed in slot 7 and at the same time have a QLE2562 HBA (N2XX-AQPCI05) installed in slot 9. Additional considerations for the Cisco 1225 VIC card: Supports 10G SFP+ optical and copper twinax connections To use the Cisco Card NIC mode, this card must be installed in PCIe slot 4, 5, 9, or 10. Slot 4, 5, 9, or 10 can operate while the server is in standby power mode. Requires that the server has CIMC firmware version 1.4(6) or later installed. There is a heartbeat LED on the top of the card that indicates when firmware is active. To use this card for UCS integration (Cisco UCS Manager mode) with Cisco UCS Manager 2.1(0) or later, the minimum card-firmware and uboot image level is 2.1(0.306). To help ensure that your operating system is compatible with the cards you have selected, please check the Hardware Compatibility List at this URL: 26
Cisco UCS C24 M3 High-Density Small Form Factor Rack-Mount Server
Cisco UCS C24 M3 High-Density Small Form Factor Rack-Mount Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.5 MARCH 20, 2013 WWW.CISCO.COM CONTENTS OVERVIEW...............................................
More informationCisco UCS C22 M3 High-Density Rack-Mount Server (Small Form Factor Hard Disk Drive Model)
Cisco UCS C22 M3 High-Density Rack-Mount Server (Small Form Factor Hard Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.1 NOVEMBER 2, 2012 WWW.CISCO.COM
More informationCisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE, CA, 95134 REV B.12 MARCH 22, 2013 WWW.CISCO.COM OVERVIEW...............................................
More informationCisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.9 JUNE 28, 2012 WWW.CISCO.COM CONTENTS OVERVIEW...............................................
More informationCisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV B.13 MARCH 20, 2013 WWW.CISCO.COM OVERVIEW...............................................
More informationCisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV B.1 NOVEMBER 8, 2012 WWW.CISCO.COM CONTENTS
More informationCisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Spec Sheet Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE, CA, 95134 REV C.15 NOVEMBER 1, 2013 WWW.CISCO.COM
More informationCisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Spec Sheet Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE, CA, 95134 REV D.19 NOVEMBER 17, 2014 WWW.CISCO.COM
More informationHow To Configure A Cisco C240 M3 High Density Libcio Rack Server (Lf) With A Power Supply And Power Supply (Power) For A Power Card (Power Card) And Power Card For A Flash Drive (Power Supply
Cisco UCS C240 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.3 JUNE 28, 2012 WWW.CISCO.COM CONTENTS
More informationCisco UCS B200 M3 Blade Server
Spec Sheet Cisco UCS B200 M3 Blade Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV B.20 NOVEMBER 25, 2013 WWW.CISCO.COM OVERVIEW...............................................
More informationCisco UCS B260 M4 Blade Server
Spec Sheet Cisco UCS B260 M4 Blade Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.2 APRIL 2, 2014 WWW.CISCO.COM CONTENTS OVERVIEW...............................................
More informationCisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Spec Sheet Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE, CA, 95134 REV C.3 JUNE 26, 2013 WWW.CISCO.COM OVERVIEW...............................................
More informationCisco UCS C240 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
Spec Sheet Cisco UCS C240 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV E.5 JUNE 29, 2015 WWW.CISCO.COM
More informationCisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
Cisco UCS C220 M3 High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE, CA, 95134 REV B.13 APRIL 24, 2013 WWW.CISCO.COM OVERVIEW...............................................
More informationCisco UCS B440 M2 Blade Server
This product has been discontinued Spec Sheet Cisco UCS B440 M2 Blade Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV B.9 MAY 20, 2015 WWW.CISCO.COM CONTENTS OVERVIEW...............................................
More informationCisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
Spec Sheet Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV B.19 MAY 29, 2015 WWW.CISCO.COM
More informationCisco UCS B22 M3 Blade Server
Spec Sheet Cisco UCS B22 M3 Blade Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.2 JULY 5, 2012 WWW.CISCO.COM CONTENTS OVERVIEW...............................................
More informationCisco UCS C3160 Rack Server
Spec Sheet Cisco UCS C3160 Rack Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.15 AUGUST 28, 2015 WWW.CISCO.COM CONTENTS OVERVIEW...............................................
More informationCisco UCS B22 M3 Blade Server
Spec Sheet Cisco UCS B22 M3 Blade Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV B.5 JANUARY 20, 2015 WWW.CISCO.COM OVERVIEW...............................................
More informationCisco UCS B200 M3 Blade Server
Spec Sheet Cisco UCS B200 M3 Blade Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.8 JUNE 15, 2012 WWW.CISCO.COM CONTENTS OVERVIEW...............................................
More informationCisco UCS B200 M3 Blade Server
Spec Sheet Cisco UCS B200 M3 Blade Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV D.10 JANUARY 5, 2016 WWW.CISCO.COM OVERVIEW...............................................
More informationCisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
Spec Sheet Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE, CA, 95134 REV B.6 FEBRUARY 2, 2016 WWW.CISCO.COM
More informationCisco UCS B200 M3 Blade Server
Spec Sheet Cisco UCS B200 M3 Blade Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV B.18 OCTOBER 16, 2013 WWW.CISCO.COM OVERVIEW...............................................
More informationCisco UCS B200 M4 Blade Server
Spec Sheet Cisco UCS B200 M4 Blade Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.13 JANUARY 15, 2015 WWW.CISCO.COM CONTENTS OVERVIEW...............................................
More informationCisco UCS B420 M4 Blade Server
Cisco UCS B420 M4 Blade Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.2 JUNE 17, 2015 WWW.CISCO.COM CONTENTS OVERVIEW...............................................
More informationCisco Unified Computing System Hardware
Cisco Unified Computing System Hardware C22 M3 C24 M3 C220 M3 C220 M4 Form Factor 1RU 2RU 1RU 1RU Number of Sockets 2 2 2 2 Intel Xeon Processor Family E5-2400 and E5-2400 v2 E5-2600 E5-2600 v3 Processor
More informationCisco UCS C200 M2 High-Performance Large Form Factor Drive Rack-Mount Server
This product has been discontinued Spec Sheet Cisco UCS C200 M2 High-Performance Large Form Factor Drive Rack-Mount Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV
More informationCisco UCS B200 M4 Blade Server
Spec Sheet Cisco UCS B200 M4 Blade Server CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.20 JUNE 9, 2015 WWW.CISCO.COM CONTENTS OVERVIEW...............................................
More informationCisco UCS C260 M2 Rackmount Servers 30 -
MS IT Hardware EPL 3658 - Server Category Document Version: 20140822 Replaced Document Version: 201400602 Updated By: Mike Kling Date: August 22, 2014 hardware disc smrtnt disc Cisco UCS C260 M2 Rackmount
More informationCisco UCS C260 M2 Rackmount Servers 30 -
MS IT Hardware EPL 3658 - Server Category Document Version: 20130311 Replaced Document Version: 20120828 Updated By: Alan Piklor Date: March, 11, 2013 hardware disc smrtnt disc Cisco UCS C260 M2 Rackmount
More informationCisco Unified Communications on the Cisco Unified Computing System
Cisco Unified Communications on the Cisco Unified Computing System Cisco is introducing software application versions from the Cisco Unified Communications portfolio (Versions 8.0(2) and later) that are
More informationCisco UCS 5108 Blade Server Chassis
Spec Sheet Cisco UCS 5108 Blade Server Chassis CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.5 APRIL 20, 2015 WWW.CISCO.COM CONTENTS OVERVIEW...............................................
More informationCisco UCS 5108 Blade Server Chassis
Spec Sheet Cisco UCS 5108 Blade Server Chassis CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.8 OCTOBER 2, 2015 WWW.CISCO.COM CONTENTS OVERVIEW...............................................
More informationSpec Sheet. Cisco R42610 Rack CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.6 DECEMBER 9, 2014 WWW.CISCO.
Spec Sheet CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.6 DECEMBER 9, 2014 WWW.CISCO.COM Overview................................................ 3 Rack Certifications
More informationCisco-EMC Microsoft SQL Server Fast Track Warehouse 3.0 Enterprise Reference Configurations. Data Sheet
Cisco-EMC Microsoft SQL Fast Track Warehouse 3.0 Enterprise Reference Configurations Data Sheet May 2011 Raghunath Nambiar Access and Virtualization Business Unit Introduction The Microsoft SQL Fast Track
More informationNEC Express5800/R120f-2M System Configuration Guide
NEC Express5800/R120f-2M System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and
More informationCisco UCS C220 M3 Server
Data Sheet Cisco UCS C220 M3 Rack Server Product Overview The Cisco Unified Computing System (Cisco UCS) combines Cisco UCS C-Series Rack Servers and B-Series Blade Servers with networking and storage
More informationData Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server
Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Strong Performance and Cluster
More informationCisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
Spec Sheet Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.8 OCTOBER 15, 2014 WWW.CISCO.COM
More informationCisco UCS C220 M3 Server
Data Sheet Cisco UCS C220 M3 Rack Server Product Overview The Cisco Unified Computing System (Cisco UCS) combines Cisco UCS C-Series Rack Servers and B-Series Blade Servers with networking and storage
More informationHigh Performance 2U Storage Server. Mass Storage Capacity in a 2U Chassis
High Performance 2U Storage Server Based on the Intel Socket R E5-2600 processor platform, the ASUS RS720-E7/RS12 server offers customers an extensive feature set: mass storage. high memory capacity, outstanding
More informationCisco UCS B440 M2 High-Performance Blade Server
Data Sheet Cisco UCS B440 M2 High-Performance Blade Server Product Overview The Cisco UCS B440 M2 High-Performance Blade Server delivers the performance, scalability and reliability to power computation-intensive,
More informationCisco UCS C420 M3 Rack Server
Data Sheet Cisco UCS C420 M3 Rack Server Product Overview The Cisco UCS C420 M3 Rack Server (Figure 1) is a high-density, 4-socket, 2-rack-unit (2RU) rack server designed for computing, I/O, storage, and
More informationDD670, DD860, and DD890 Hardware Overview
DD670, DD860, and DD890 Hardware Overview Data Domain, Inc. 2421 Mission College Boulevard, Santa Clara, CA 95054 866-WE-DDUPE; 408-980-4800 775-0186-0001 Revision A July 14, 2010 Copyright 2010 EMC Corporation.
More informationFUJITSU Enterprise Product & Solution Facts
FUJITSU Enterprise Product & Solution Facts shaping tomorrow with you Business-Centric Data Center The way ICT delivers value is fundamentally changing. Mobile, Big Data, cloud and social media are driving
More informationCisco UCS C240 M4 High-Density Rack Server (Large Form Factor Disk Drive Model)
Spec Sheet Cisco UCS C240 M4 High-Density Rack Server (Large Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV B.19 JUNE 19, 2015 WWW.CISCO.COM
More information1 of 10 12/29/2015 11:40 AM
PowerEdge T320 Tower Server Starting Price $4,101.99 Instant Savings $1,254.72 Subtotal $2,847.27 As low as $86.00 /month^ Dell Business Credit Apply Discount Details Ships in 2-4 Business Days My Selections
More informationHUAWEI Tecal E6000 Blade Server
HUAWEI Tecal E6000 Blade Server Professional Trusted Future-oriented HUAWEI TECHNOLOGIES CO., LTD. The HUAWEI Tecal E6000 is a new-generation server platform that guarantees comprehensive and powerful
More informationCisco UCS C24 M3 Server
Data Sheet Cisco UCS C24 M3 Rack Server Product Overview The form-factor-agnostic Cisco Unified Computing System (Cisco UCS ) combines Cisco UCS C-Series Rack Servers and B-Series Blade Servers with networking
More information5520UR 00UR 00UR 625UR 625URSAS 00UR URBRP 600URLX 625URLX
Intel Server Board S5520 5520UR Intel Server System SR600 00UR Intel Server System SR600 00UR URHS Intel Server System SR625UR Intel Server System SR625UR 625URSAS Intel Server System SR2600 00UR URBRP
More informationAcer AR180 F1 specifications
Product overview The Acer AR180 F1 dual-socket server delivers solid performance, scale-up flexibility, and optimized storage capacity in a 2U modular form factor. Comprehensive management utilities and
More informationCisco 7816-I5 Media Convergence Server
Cisco 7816-I5 Media Convergence Server Cisco Unified Communications Solutions unify voice, video, data, and mobile applications on fixed and mobile networks, enabling easy collaboration every time from
More informationIBM System x family brochure
IBM Systems and Technology System x IBM System x family brochure IBM System x rack and tower servers 2 IBM System x family brochure IBM System x servers Highlights IBM System x and BladeCenter servers
More informationData Sheet FUJITSU Server PRIMEQUEST 2400E Mission Critical
Data Sheet FUJITSU Server PRIMEQUEST 2400E Mission Critical Data Sheet FUJITSU Server PRIMEQUEST 2400E Mission Critical No Time for Downtime Combining the power of Intel Xeon E7 family processors, the
More informationTS500-E5. Configuration Guide
TS500-E5 Configuration Guide E4631 Second Edition V2 March 2009 Copyright 2009 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may
More informationCisco SmartPlay Select. Cisco Global Data Center Promotional Program
Cisco SmartPlay Select Cisco Global Data Center Promotional Program SmartPlay Select Program Program Goals and Benefits UCS Promotional offers to accelerate new UCS customers acquisition by showcase Cisco
More informationU.S. Product Specifications Reference PSREF. Version 483, December 2015. ThinkServer Servers. Visit www.lenovo.com/psref for the latest version
U.S. Product Specifications Reference PSREF Version 483, December 2015 ThinkServer Servers Visit www.lenovo.com/psref for the latest version Contents Summary of Changes...1 ThinkServer Servers...4 ThinkServer
More informationUp to 4 PCI-E SSDs Four or Two Hot-Pluggable Nodes in 2U
Twin Servers Up to 4 PCI-E SSDs Four or Two Hot-Pluggable Nodes in 2U New Generation TwinPro Systems SAS 3.0 (12Gbps) Up to 12 HDDs/Node FDR(56Gbps)/QDR InfiniBand 1TB DDR3 up to 1866 MHz in 16 DIMMs Redundant
More informationHigh Performance 1U Server. High Performance 1U Storage Server. Front Parallel CPU Design features better cooling
High Performance 1U Server The ASUS RS700-E7/RS8 1U server is based on dual Intel Socket R series processors (135W), designed with 24 DIMM slots to support up to 512GB memory. It features an optimized
More informationHow To Build A Cisco Ukcsob420 M3 Blade Server
Data Sheet Cisco UCS B420 M3 Blade Server Product Overview The Cisco Unified Computing System (Cisco UCS ) combines Cisco UCS B-Series Blade Servers and C-Series Rack Servers with networking and storage
More informationHUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6800 Data Center Server
HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6800 Data Center Server HUAWEI FusionServer X6800 Data Center Server Data Center Cloud Internet App Big Data HPC As the IT infrastructure changes with
More informationPart-1: SERVER AND PC
Part-1: SERVER AND PC Item Item Details Manufacturer Quantity Unit Price Total Dell server or equivalent Intel Xeon E5-2420 1.90GHz, 15M Cache, 7.2GT/s QPI, Turbo, 6C, 95W or equivalent PCIE Riser for
More informationAcer AT350 F1 specifications
Product overview The Acer AT350 F1 is a dual-socket tower or 4U rack mountable server for flexible environment delivering blazing performance and exceptional expansion capability. Offering high reliability,
More informationUCS M-Series Modular Servers
UCS M-Series Modular Servers The Next Wave of UCS Innovation Marian Klas Cisco Systems June 2015 Cisco UCS - Powering Applications at Every Scale Edge-Scale Computing Cloud-Scale Computing Seamlessly Extend
More informationCisco UCS B200 M3 Blade Server
Data Sheet Cisco UCS B200 M3 Blade Server Product Overview The Cisco Unified Computing System (Cisco UCS ) combines Cisco UCS B-Series Blade Servers and C-Series Rack Servers with networking and storage
More informationTipos de Máquinas. 1. Overview - 7946 x3550 M2. Features X550M2
Tipos de Máquinas X550M2 1. Overview - 7946 x3550 M2 IBM System x3550 M2 Machine Type 7946 is a follow on to the IBM System x3550 M/T 7978. The x3550 M2 is a self-contained, high performance, rack-optimized,
More informationThe Future of Computing Cisco Unified Computing System. Markus Kunstmann Channels Systems Engineer
The Future of Computing Cisco Unified Computing System Markus Kunstmann Channels Systems Engineer 2009 Cisco Systems, Inc. All rights reserved. Data Centers Are under Increasing Pressure Collaboration
More informationPower Redundancy. I/O Connectivity Blade Compatibility KVM Support
1.Blade server Blade Chasis Specification Blade Chassis Form Factor 6U-10U rack mountable Chasis to House at least 6 or more Blade Servers Chasis Should be configured with 6 blades Network Redundancy I/O
More informationROSA Server MKVI. A Complete, Powerful Solution
Cisco ROSA Server MKVI Description Working in harmony with the Cisco ROSA management software, the ROSA Server provides the user with outstanding reliability and flexibility. Together, ROSA Server MKVI
More informationChapter 5 Cubix XP4 Blade Server
Chapter 5 Cubix XP4 Blade Server Introduction Cubix designed the XP4 Blade Server to fit inside a BladeStation enclosure. The Blade Server features one or two Intel Pentium 4 Xeon processors, the Intel
More informationData Sheet FUJITSU Server PRIMEQUEST 2800B Business Critical
Data Sheet FUJITSU Server PRIMEQUEST 2800B Business Critical Data Sheet FUJITSU Server PRIMEQUEST 2800B Business Critical Advanced 8-socket enterprise platform for business critical apps Combining the
More informationNEC EXPRESS5800/R320c-E4 Configuration Guide
NEC EXPRESS5800/R320c-E4 Configuration Guide VMware model Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure
More informationCisco Secure Network Server
Data Sheet Cisco Secure Network Server Product Overview Granting and denying network access has evolved beyond simple user name and password verifications. Today, additional attributes related to users
More informationAcer AT110 F2 Specifications
Product overview The AT110 F2 delivers true server-class features and expandability along with best price-performance technology to assure the success of your small-sized business. This single-socket tower
More informationSun Microsystems Special Promotions for Education and Research January 9, 2007
Sun Microsystems Special Promotions for Education and Research Solve big problems on a small budget with Sun-Education s trusted partner for cutting-edge technology solutions. Sun solutions help your campus
More informationSUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION
SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION AFFORDABLE, RELIABLE, AND GREAT PRICES FOR EDUCATION Optimized Sun systems run Oracle and other leading operating and virtualization platforms with greater
More informationCisco MCS 7825-H3 Unified Communications Manager Appliance
Cisco MCS 7825-H3 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables
More informationData Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade
Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade Universal dual socket server blade with high computing and I/O performance in a small form factor The PRIMERGY BX Blade Servers are the ideal
More informationCG2100 Carrier Grade Server. Document Revision 1.2
CG2100 Carrier Grade Server Document Revision 1.2 September 2014 Revision History Revision Date Comments 1.0 April 29, 2010 Initial revision for production. 1.1 March 30, 2011 1.2 September 17, 2014 Added
More informationCisco UCS B-Series M2 Blade Servers
Cisco UCS B-Series M2 Blade Servers Cisco Unified Computing System Overview The Cisco Unified Computing System is a next-generation data center platform that unites compute, network, storage access, and
More informationCisco UCS B460 M4 Blade Server
Data Sheet Cisco UCS B460 M4 Blade Server Product Overview The new Cisco UCS B460 M4 Blade Server uses the power of the latest Intel Xeon processor E7 v2 product family to add new levels of performance
More informationHow To Configure Your Computer With A Microsoft X86 V3.2 (X86) And X86 (Xo) (Xos) (Powerbook) (For Microsoft) (Microsoft) And Zilog (X
System Configuration and Order-information Guide RX00 S4 February 008 Front View CD-ROM Drive (Optional) Hard Disk Bay Back View PCI Slot 0/00/000BASE-T connector Serial Port Display Mouse Keyboard Inside
More informationCisco for SAP HANA Scale-Out Solution on Cisco UCS with NetApp Storage
Cisco for SAP HANA Scale-Out Solution Solution Brief December 2014 With Intelligent Intel Xeon Processors Highlights Scale SAP HANA on Demand Scale-out capabilities, combined with high-performance NetApp
More information1. Specifiers may alternately wish to include this specification in the following sections:
GUIDE SPECIFICATION Seneca is a leading US designer and manufacturer of xvault security and surveillance solutions. The xvault product line combines our IP expertise and solution partnerships with certified
More informationSpares/Accessories List and Configuration Guide
Intel Server System family R000GZ/GL Intel Server System family R2000GZ/GL Spares/Accessories List and Configuration Guide A reference guide to assist customers in ordering the necessary components to
More informationData Sheet FUJITSU Server PRIMERGY RX200 S8 Dual socket 1U rack server
Data Sheet FUJITSU Server PRIMERGY RX200 S8 Dual socket 1U rack server Data Sheet FUJITSU Server PRIMERGY RX200 S8 Dual socket 1U rack server Maximum productivity in a 1U housing The PRIMERGY RX Rack Server
More informationA Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.
Appro HyperBlade A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing. Appro HyperBlade clusters are flexible, modular scalable offering a high-density
More informationNew levels of efficiency and optimized design. The latest Intel CPUs. 2+1 expandability in UP 1U
New levels of efficiency and optimized design As always, ASUS makes servers that deliver superior performance. In this generation, the ASUS RS300-E8-RS4 supports the latest Intel Xeon E3-1200 v3 processor
More informationAPACHE HADOOP PLATFORM HARDWARE INFRASTRUCTURE SOLUTIONS
APACHE HADOOP PLATFORM BIG DATA HARDWARE INFRASTRUCTURE SOLUTIONS 1 BIG DATA. BIG CHALLENGES. BIG OPPORTUNITY. How do you manage the VOLUME, VELOCITY & VARIABILITY of complex data streams in order to find
More informationIBM System x family brochure
IBM Systems and Technology System x IBM System x family brochure IBM System x rack, BladeCenter and tower servers 2 IBM System x family brochure Highlights IBM System x and BladeCenter servers help deliver
More informationData Sheet FUJITSU Server PRIMEQUEST 2400E2 Mission Critical
Data Sheet FUJITSU Server PRIMEQUEST 2400E2 Mission Critical Data Sheet FUJITSU Server PRIMEQUEST 2400E2 Mission Critical No Time for Downtime Combining the power of Intel Xeon Processor E7 family, the
More informationTerms of Reference Microsoft Exchange and Domain Controller/ AD implementation
Terms of Reference Microsoft Exchange and Domain Controller/ AD implementation Overview Maldivian Red Crescent will implement it s first Microsoft Exchange server and replace it s current Domain Controller
More informationSUN/Oracle WSCA Price List. Please call (877) SUN-LATG (877) 786-5284 (504) 304-2505 Or Fax (504) 617 6670 Or e-mail wsca@latg.net
SUN/Oracle WSCA Price List Please call (877) SUNLATG (877) 7865284 (504) 3042505 Or Fax (504) 617 6670 Or email wsca@latg.net WSCA Price List Updated January Item Item Description Named Product List Price
More informationData Sheet FUJITSU Server PRIMERGY RX100 S8 Mono socket 1U rack server
Data Sheet FUJITSU Server PRIMERGY RX100 S8 Mono socket 1U rack server Data Sheet FUJITSU Server PRIMERGY RX100 S8 Mono socket 1U rack server Small in size and low in cost rich in optional features FUJITSU
More informationOptimized dual-use server and high-end workstation performance
Optimized dual-use server and high-end workstation performance The ATX-sized(EEB mounting hole locations) Z9PA-U8 supports the latest Intel Xeon processor E5-2600 and E5-1600 product family, featuring
More informationAn Oracle White Paper. Oracle s Sun Server X4-2 and Sun Server X4-2L System Architecture
An Oracle White Paper Oracle s Sun Server X4-2 and Sun Server X4-2L System Architecture Introduction...3 Sun Server X4-2...4 Sun Server X4-2L...5 Comparing the Sun Server X4-2 and Sun Server X4-2L...6
More informationSystem Configuration and Order-information Guide ECONEL 100 S2. March 2009
System Configuration and Orderinformation Guide ECONEL 100 S2 March 2009 Front View DVDROM Drive 5 inch Bay Floppy Disk Drive Back View Mouse Keyboard Serial Port Display 10/100/1000BASET Connector Inside
More informationData Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000
Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000 Datasheet for Red Hat certification PRIMERGY CX1000 is a new product category within the PRIMERGY x86 server family. Its focus
More informationCisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)
Spec Sheet Cisco UCS C220 M4 High-Density Rack Server (Small Form Factor Disk Drive Model) CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE, CA, 95134 REV A.5 OCTOBER 15, 2014 WWW.CISCO.COM
More informationServers, Clients. Displaying max. 60 cameras at the same time Recording max. 80 cameras Server-side VCA Desktop or rackmount form factor
Servers, Clients Displaying max. 60 cameras at the same time Recording max. 80 cameras Desktop or rackmount form factor IVR-40/40-DSKT Intellio standard server PC 60 60 Recording 60 cameras Video gateway
More information