Siemens DECT Engine MD32. Product Description. Information and Communication Products

Size: px
Start display at page:

Download "Siemens DECT Engine MD32. Product Description. Information and Communication Products"

Transcription

1 Siemens DECT Engine MD32 Product Description Siemens DECT Engine MD32 1/16 Product Description

2 The Siemens DECT Engine MD32 is a module offering an easy way to provide a radio connection for data transmission to any kind of application. The module is integrated into a host system and is accessed by the host application via a serial line (RS232 interface). The Siemens DECT Engine MD32 incorporates the complete RF part and autonomously runs the DECT protocol. 2 Power 5V Power Supply Radio Interface Host Interface FFC Connector 20 pin Power on/off 1 V.24/Ports 8 Audio 4 analogue Lock_Ind 1 Reset 1 2 DECT- Controller RF Control Data DECT RF Part antenna 1/2 RF Ant.- switch Diversity * option wire ant. 1 * wire ant. 2 * 50 Ohm point 1 50 Ohm point 2 Features: Data transmission with data rates of up to 19.2 kbps Conforms to DECT standard Serial 3V RS232 interface to host system A terminal (portable part, ) can subscribe on up to 6 base stations (fixed part, FP) Control of up to 16 terminals from one base station (FP) running 4 simultaneous links at one time Possibility of building a system of up to 6 base stations with up to 16 terminals roaming through this multi-cell environment Single 5V power supply Mounting points for two plug-in wire antennae Solder pads for two PCB mount angle cable terminators for external antennae Supports antenna diversity in base station modes Small mechanical dimensions (65 x 37 x 5 mm) Note: The analogue port is reserved for future enhancements with voice transmission. Siemens DECT Engine MD32 2/16 Product Description

3 1 Functionality 1.1 Modes of Operation Configuration The Siemens DECT Engine MD32 can be configured to any of three different modes of operation: V.24 Replacement (Portable Part) V.24 Replacement FP (Fixed Part) V.24 Server FP (Fixed Part) The Configuration Mode is entered with a specific sequence on the RS232 signal RTS or by submitting a special escape sequence to the module via the V.24 interface. After submitting this sequence the DECT Engine interprets all data arriving at the serial interface as AT commands. The commands implemented are a subset of the V.25ter commands with extensions for accessing internal configuration registers (S-register). These registers are kept as a profile in the permanent memory of the Siemens DECT Engine MD32. After the configuration mode is exited either by AT command or reset, the module starts operating in the configured mode. This applies also for activation of the module by power-on. The configuration data of a fixed part are retained when reconfiguring the module as a portable part and vice versa. The Siemens DECT Engine may operate in only one mode at a given time. It is possible to change the mode of operation by resetting the module and reconfiguring it V.24 Replacement /FP This mode allows replacement of the RS232 cable of a point to point connection (e.g. a PC to a PC) by a point to-point radio link. The Siemens DECT Engine emulates an RS232 cable and transfers information on the RS232 circuits transparently to a V.24 Replacement FP/V.24 Server FP in both directions using an error correction protocol conformant with the LU10 standard. This assures a BER of less than A V.24 Replacement can enroll in up to 6 fixed parts (FP). A V.24 Replacement FP can enroll in up to 16 Portable Parts (). The subscription can be done in two different ways. The first way is to start a subscription procedure in the and the FP together with an optional PIN using an AT command. All the required information is exchanged on air. The second possibility is to exchange this information under control of the host application using AT commands. Switching between portable or fixed part mode is only possible during configuration. Once a or FP is selected only point-to-point connections are possible. Siemens DECT Engine MD32 3/16 Product Description

4 DTE (PC) MD32 DECT MD32 FP RX RX TX TX RTS RTS CTS CTS DTR DTR DSR DSR DCD DCD RI RI DTE (PC) Example of a Zero Modem Connection using V.24 Replacement /FP V.24 Sever FP This mode allows control of up to 16 V.24 Replacement s running 4 connections at the same time. For this reason a special packet-oriented V.24 protocol has been introduced that supports up to 16 virtual V.24 interfaces. This protocol maps up to 16 physical RS232 interfaces related to the 16 enrolled V.24 Replacement s to the physical RS232 interface of the V.24 Server FP. A packet of this protocol contains an address header, a status field with the RS232 control signals of the corresponding V.24 Replacement, a length field and a data field. The host application has to support this protocol. The following picture shows the topology of this operation environment with 4 concurrent connections: DCE Appl. 1 FP DCE Appl. 2 FP DCE Appl. 15 FP Virtual World Virtual COM1 Virtual COM2 Virtual COM15 Physical COM Physical World MD32 Physical 1 COM1 2 Server Multi Link 15 Physical COM2 MD32 FP DTE Appl. 1 Physical COM15 Appl. 2 DTE DTE Appl. 15 DCE Appl. 16 FP Virtual COM16 Host Computer e. g. PC 16 Physical COM16 Appl. 16 DTE Note, that only HW handshake is possible between the virtual V.24 interface within the host system and the physical RS232 interface of the terminal! With the first request for data transfer of either the server host or the terminal host, a connection is established at the DECT level. The time this link is held active after data have been transmitted can be set by AT commands. There are two basic different scenarios depending on the setting of this time: If the time until an automatic release is very long, four established links will block further terminals from contacting the server. This may induce delay if a terminal wants to start a transaction with the host. On the other hand, response times for the established links are quite short. This scenario resembles circuit-switched data transfer. It is recommended when the DECT link is part of a connection which uses telephone networks. If the waiting time is very short, the radio link will be released shortly after the Siemens DECT Engine MD32 4/16 Product Description

5 transmission of the data packet. Consequently, the server module is freed to respond to connections from other terminals. This scenario resembles packet-switched data. It should be used when the terminal is connected to data networks via ethernet. 1.2 Multicell Systems The following figure gives an example of a multicell environment with two V.24 Server FPs and four V.24 Replacement s. A V.24 Replacement leaving the coverage area of an DP is indicated by LOC_IND = OFF. The DECT Engine switches to another FP automatically. As an alternative this switching to another FP can be done under control of the terminal host using an AT command. When changing the FP an active data transmission is aborted and buffered data are lost. The host application has to consider this FP FP V.24 V.24 4 PC Siemens DECT Engine MD32 5/16 Product Description

6 2 Host Interface A 20-pin connector (AVX ) for Flat Flexible Cables (FFC) of 0.5- mm pitch and 0.3-mm thickness connects the module to the host device. It has the following interfaces. 2.1 Data Interface The Data Interface is realized with a serial asynchronous transmitter and receiver according to TTU-T RS232 Interchange Circuits DCE. It is set to 8 data bits, no parity, 1 stop bit and can be run at 9.6 kbps or 19.2 kbps. In-band (HW handshake via RTS/CTS) and out-band (via XON/XOFF) flow control is supported. In addition, the modem control signals DTR, DSR, DCE and RI are available. The Data interface works at 3.3V TTL RS232 without level shifters for +/- 12V signal levels. The polarity of the signals is therefore inverted, e.g. off is high TTL level, on low TTL level. 2.2 Control Signals The following control signals are available (3V TTL level): Inputs: RST =1 0 edge the DECT Engine will be reset =0 or 1 normal operation PON =0 power save mode (all voltage regulators switched off), no operation =1 DECT Engine is switched on (active) Outputs: LOCK_IND =0 Siemens DECT Engine (configured as ) is locked on FP (e.g. there is a base station within reach to which the terminal DECT Engine is subscribed) =1 Siemens DECT Engine (configured as ) is unlocked on FP (e.g. there is no base station within reach to which the terminal DECT Engine is subscribed) RI =0 Ring Indicate (indicates a incoming call). Wakeup of host application. =1 No Operation Siemens DECT Engine MD32 6/16 Product Description

7 2.3 Power Supply A single +5V voltage supplies the module. Linear regulators stabilize the supply voltages for the DECT Controller and for the RF part. A DECT Engine changes automatically to standby mode when the air link to the base station is released. The delay between sending the last data and release of the link can be adjusted by AT commands during configuration. The standby mode is exited when a new link has to be established (either by incoming data on the serial line or a request from the base station). An FP DECT Engine has no power-reduced mode for it is constantly sending although no link is established. This is required in order to keep the corresponding DECT Engine(s) synchronized to the FP. All linear regulators can be switched off by the DECT Controller if the PON signal is not active. The module is then in the power save mode. No Rx/Tx modes are possible. The Siemens DECT Engine can be switched on again with PON = active. Siemens DECT Engine MD32 7/16 Product Description

8 2.4 Pin Assignment Function Signal PIN I/O Description Power VCC 1, 2 positive voltage supply +5V GND 19, 20 Ground Power on/off PON 16 I high = on (standby) low = off (power save) Restart RST 6 I high = nop high to low edge = Reset of MD32 (t low >100ns) low = nop : Idle lock indicator FP: not used LOCK_IND 4 O low = locked on FP high = unlocked on FP RS232 Received Data from MD32 RXD 12 O high=1 low=0 RS232 Transmit Data to MD32 TXD 15 I high=1 low=0 RS232 Ready To Send to MD32 RTS 11 I high = off low = on RS232 Clear to Send to host CTS 14 O high = off low = on RS232 Data Terminal Ready DTR 10 I high = off low = on RS232 Data Set Ready DSR 5 O high = off low = on RS232 Ring Indication RI 7 O high = off low = on (may wake up host system) RS232 DCD 13 O high = off Data Channel Detect Audio Interface (Gain-adjustable with AT commands) low = on Differential Codec analog Input (reserved for future use) Differential Codec analog Output (reserved for future use) MIC+ 18 I MIC- 17 I LRS+ 8 O LRS- 9 O reserved I/0 Port GP 3 nop = no operation must be unconnected Siemens DECT Engine MD32 8/16 Product Description

9 3 Radio Interface The DECT Controller handles all signal and data processing needed within a DECT device. Internal software runs the host interface and the whole DECT protocol stack. A UART forms the interface to the host system. Internal ROM stores the program SW and flash memory-permanent parameters. RAM is used for data buffers and registers. The RF part of the DECT Engine MD32 is based on Siemens one-chip transceiverintegrated circuit using B6HF bipolar technology. To achieve maximum output power, modern GaAs-FET technology is established during final power amplifier stages. The DECT Engine MD32 provides excellent signal quality even in poor RF environments by supporting antenna diversity capability. If the Siemens DECT Engine MD32 is configured as, the antenna diversity switch is fixed to one position. The position can be modified by AT command. The module allows connection of two types of antennae. Wire antennae are clipped to holes in the PCB. They will be delivered with each DECT Engine. For applications with external antennae, it is possible to solder 50-ohm PCB mount angle cable terminator for the external antenna coax cable type SUHNER 86 MCX The solder pads are 50-ohm matched. For each type there are two connection points to support antenna diversity. Siemens DECT Engine MD32 9/16 Product Description

10 4 Mechanical Characteristics Antenna 1 Antenna 2 Antenna 1 Antenna 2 Siemens DECT Engine MD32 10/16 Product Description

11 1 2 SUHNER 86 MCX Koax Cable for Antenna 1 Koax Cable for Antenna 2 ZIF FFC Cable 0.5 mm pitch 20 pins 0.3mm thickness e.g. by Molex FFC Connector (AVX ) max. cable length: 200 mm Weight: Module 10.7 g Two antennae 0.3 g Siemens DECT Engine MD32 11/16 Product Description

12 5 Electrical and Radio Characteristics 5.1 Absolute maximum ratings Parameter Min Max Units Supply voltage VCC V Voltage on digital pins 3-7, V Voltage on analog pins 8, 9, 17, V I-protection diodes on any pin 50 µa Storage temperature C Values beyond which damage to the device may occur. 5.2 Operating Conditions Parameter Min Typ Max Units Ambient temperature 0 40 C Supply voltage VCC V 5.3 Power Supply Parameter Description Conditions Min Typ Max Units V VCC I VCC Supply voltage I VCC = 40mA V Voltage drop I VCC = 450mA 350 mv Added ripple I VCC = mA 100 mv Supply current Power Save Mode 100 µa average Synchronisation 80 ma for t=2s (Power Standby consumption) normal duty cycle ma low duty cycle 4 5 ma Idle FP ma One active voice ma or data channel FP ma Every additional ma data channel 1) FP ma Supply current peak Peak current (during ma transmission slot 417µs) () Siemens DECT Engine configured as Portable Part only (FP) Siemens DECT Engine configured as Fixed Part only 1) max. number of simultaneous channels: : 1 FP: for handover Siemens DECT Engine MD32 12/16 Product Description

13 5.4 Digital I/O s Parameter Description Conditions Min Typ Max Units V IL Logic 0 input level 0.6V V V ich Logic 1 input level 2.4 V I in Input current V in =3V 10 µa V in =GND 100 µa V OL Logic 0 output level I out =2mA V V OH Logic 1 output level I out =2mA V I out Output current 2 ma t OR Output rise time C LOAD <=10p 100 ns t OF Output fall time 100 ns t IR allowed input rise C LOAD <=20p 500 ns time t IF allowed input fall time 500 ns 5.5 Timing characteristics Parameter (times) Min Typ Max Units Start up to locked time: 2 s VCC=on to LOCK_IND=0 ( locked) Wake up to lock time: 2 s PON=1 to LOCK_IND=0 ( locked) Start up time after reset 2 s RST =1 0 to LOCK_IND=0 ( locked) time to ready to receive data via RS s after reset or Power on Delay Locked Active Link normal duty cycle low duty cycle ms ms Data or Speech Transmission Delay 20 ms (Data In Data Out) Data Transmission Delay 35 (Data In Data Out) Baud Rate on serial Interface kbit/s Siemens DECT Engine MD32 13/16 Product Description

14 5.6 Air Interface Parameter Min Typ Max Units Frequency range MHz RF Power 250 mw RF channels 10 Carrier spacing MHz Multiplex, Duplex TDMA / FDM, TDD Time slots 24 Time slots usable RX/TX 6/6 Frame duration 10 ms Modulation GFSK, BT=0.5 Gross Bit Rate (frame) 1,152 MBps Net Bit Rate speech 32 kbps Net Bit Rate data protected 19.2 kbps Data protection CRC, ARQ, LU10 protocol Receiver input sensitivity dbm at BER 0.1% channel allocation instant dynamic coverage range line of sight 300 m coverage range indoor 50 m Siemens DECT Engine MD32 14/16 Product Description

15 6 Type approval The DECT Engine is approved in its reference configuration in accordance with the currently valid telecommunications regulations and bears the appropriate CE label. The following test reports of an accredited test laboratory are obtainable and can be made available to customers for their conformity declarations: CTR6 Fixed Part CTR6 Portable Part EMC (in accordance with ETS ) LVD (in accordance with EN 60950) When the DECT-Engine is used in customer applications, evidence of conformity with the essential requirements of the R&TTE Directive is to be provided in the form of a conformity assessment procedure. The essential requirements include: 1. Protecting of the health and the safety of the user, 2. Protection requirements relating to EMC, 3. Effective use of the assigned spectrum so as to avoid harmful interference. The conformity declaration concerning the radio part of the device including the DECT Engine MD32 can be made on the basis of the available test reports. This however requires that the conditions of use laid down in the technical documentation of the DECT Engine MD32 such as temperature, supply voltage and antenna installation are adhered to and no directional antennas, active antennas or boosters will be used. Under these conditions no further measurements are necessary. When making adjustments for certification of the other functionalities of the devices (esp. the measurements to ensure the requirements 1 and 2) it is mandatory that the DECT Engine MD32 is transmitting data during the measurements. 7 Support The following solution development kits are available: Evaluation Kit: - 3 Siemens DECT Engines MD32 with all necessary adapters, cables and power supply units - Further detailed technical description and demonstration software as binaries and source code will be supplied via or internet. Development Support Kit: - 1 Siemens DECT Engine MD32 - Adapter board with all necessary cables and power supply units Together with delivery of any kit access to hotline service of the suppliers (Siemens or distribution partner) is available. Siemens DECT Engine MD32 15/16 Product Description

16 Issued by Information and Communication Products Group Hofmannstr. 51, Munich, Germany, Siemens Aktiengesellschaft Subject to availability. Right of modification reserved. Siemens DECT Engine MD32 16/16 Product Description

Siemens DECT Engine MD32

Siemens DECT Engine MD32 Siemens Technical Description Preliminary Technical Description 4-1 Issue: 1999-11-5 Table of Contents 1 Introduction... 4-3 1.1 History... 4-3 1.2 References... 4-3 1.3 Terms and abbreviations... 4-3

More information

LOW COST GSM MODEM. Description. Part Number

LOW COST GSM MODEM. Description. Part Number Dual Band 900 / 1800 MHz Fax, SMS and Data Integral SIM Card holder Siemens TC-35i GSM Engine Rugged Extruded Aluminium Enclosure Compact Form Factor 86 x 54 x 25mm RS232 Interface with Auto baud rate

More information

MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual

MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual Version: 1.0.1 Dec. 2005 Table of Contents I. Introduction 2 II. Operations 2 II.1. Theory of Operation 2 II.2. Configuration (PC-PC

More information

Advanced Data Capture and Control Systems

Advanced Data Capture and Control Systems Advanced Data Capture and Control Systems Tronisoft Limited Email: sales@tronisoft.com Web: www.tronisoft.com RS232 To 3.3V TTL User Guide RS232 to 3.3V TTL Signal Converter Modules P/N: 9651 Document

More information

HAC-LM Series Low Power Data Radio Module

HAC-LM Series Low Power Data Radio Module HAC-LM Series Low Power Data Radio Module Version 3.0 SHENZHEN HAC TELECOM TECHNOLOGY CO., LTD Address : 3rd Area, 19 th Fl, Tower A, HaiSong Building, Tai Ran 9 th Rd, Futian, ShenZhen, China. Tel : +86-755-23981078

More information

Single channel data transceiver module WIZ2-434

Single channel data transceiver module WIZ2-434 Single channel data transceiver module WIZ2-434 Available models: WIZ2-434-RS: data input by RS232 (±12V) logic, 9-15V supply WIZ2-434-RSB: same as above, but in a plastic shell. The WIZ2-434-x modules

More information

SyncLink GT2/GT4 Serial Adapter

SyncLink GT2/GT4 Serial Adapter SyncLink GT2/GT4 Serial Adapter Hardware User s Manual MicroGate Systems, Ltd http://www.microgate.com MicroGate and SyncLink are registered trademarks of MicroGate Systems, Ltd. Copyright 2008 2012 MicroGate

More information

DECT Module UM-9802 Datasheet

DECT Module UM-9802 Datasheet UWIN TECHNOLOGIES CO., LTD. DECT Module UM-9802 Datasheet V2.1 1 UWIN TECHNOLOGIES CO., LTD. Contents 1. Introduction... 3 2. Features... 3 3. DECT Module Application... 3 4. DECT Module function block...

More information

Manual Serial PCI Cards

Manual Serial PCI Cards Manual Serial PCI Cards W&T Models 13011, 13410 13411, 13610 13611, 13812 Version 1.4 Subject to error and alteration 37 01/2005 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make

More information

How To Use An Adh8012 Gsm Gprs Module With A Gsm 2.2.2 (Gsm) Gpros (Gsp) Gpls (Geo) Gsp (Gpl) Gs

How To Use An Adh8012 Gsm Gprs Module With A Gsm 2.2.2 (Gsm) Gpros (Gsp) Gpls (Geo) Gsp (Gpl) Gs ADH Technology Co. Ltd. ADH8012 GSM GPRS Modem User s Manual www.adh-tech.com.tw sales@adh-tech.com.tw Page 1 Content ADH8012 GSM GPRS Modem User s Manual... 1 1. Introduction... 3 2. Product concept...

More information

HAC-UM Series SHENZHEN HAC TECHNOLOGY CO., LTD. HAC-UM Series. Version 2.3C SHENZHEN HAC TELECOM TECHNOLOGY CO., LTD

HAC-UM Series SHENZHEN HAC TECHNOLOGY CO., LTD. HAC-UM Series. Version 2.3C SHENZHEN HAC TELECOM TECHNOLOGY CO., LTD HAC-UM Series Version 2.3C SHENZHEN HAC TELECOM TECHNOLOGY CO., LTD Address : 3rd Area, 19 th Fl, Tower A, HaiSong Building, Tai Ran 9 th Rd, Futian, ShenZhen, China. Tel : +86-755-23981078 23981077 Fax

More information

Cable Specifications and Information

Cable Specifications and Information APPENDIX A This appendix provides the connector and pinout information you need for making or purchasing cables used with Cisco VG224 voice gateway. To order cables from Cisco, see the Obtaining Technical

More information

RS-232 COMMUNICATIONS

RS-232 COMMUNICATIONS Technical Note D64 0815 RS-232 COMMUNICATIONS RS-232 is an Electronics Industries Association (EIA) standard designed to aid in connecting equipment together for serial communications. The standard specifies

More information

Quectel Cellular Engine

Quectel Cellular Engine Cellular Engine GSM UART Port Application Notes GSM_UART_AN_V1.01 Document Title GSM UART Port Application Notes Version 1.01 Date 2009-11-16 Status Document Control ID Release GSM_UART_AN_V1.01 General

More information

USB to serial chip CH340

USB to serial chip CH340 The DataSheet of CH340 (the first) 1 1. Introduction USB to serial chip CH340 English DataSheet Version: 1D http://wch.cn CH340 is a USB bus convert chip and it can realize USB convert to serial interface,

More information

Hardware Interface Description

Hardware Interface Description Hardware Interface Description EZ10 GPS PY Terminal Telit Cellular GPS Engine Version: 06.00A EZ10 GPS PY Terminal_HD_V06.00A 1.Jan.2007 1. Key Features of the EZ10 GPS PY Terminal Feature Implementation

More information

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014 EZmoto V2 Product description Rev. 6 10/01/2014 1 Contents 1. Overview... 3 2. Hardware Interface Description... 3 2.1 Main features of the EZmoto... 3 2.2 Hardware block diagram... 4 2.3 Internal Hardware

More information

GTS-4E Hardware User Manual. Version: V1.1.0 Date: 2013-12-04

GTS-4E Hardware User Manual. Version: V1.1.0 Date: 2013-12-04 GTS-4E Hardware User Manual Version: V1.1.0 Date: 2013-12-04 Confidential Material This document contains information highly confidential to Fibocom Wireless Inc. (Fibocom). Fibocom offers this information

More information

Bluetooth UART/RS232 Module

Bluetooth UART/RS232 Module Introduction BLUEMORE600 is a professional, slim, wireless module ready for integration in brand new or existing electronic products. Based on CSR chipset BC03MM it s fully compatible for Serial Port profiles.

More information

MANUAL FOR RX700 LR and NR

MANUAL FOR RX700 LR and NR MANUAL FOR RX700 LR and NR 2013, November 11 Revision/ updates Date, updates, and person Revision 1.2 03-12-2013, By Patrick M Affected pages, ETC ALL Content Revision/ updates... 1 Preface... 2 Technical

More information

LS-101 LAN to Serial Device server. User s Manual

LS-101 LAN to Serial Device server. User s Manual LS-101 LAN to Serial Device server User s Manual Revision History Revision No Date Author Remarks 0.1 August 29, 2001 IDC Initial document INTRODUCTION Overview Almost all instruments and most industrial

More information

BLUETOOTH SERIAL PORT PROFILE. iwrap APPLICATION NOTE

BLUETOOTH SERIAL PORT PROFILE. iwrap APPLICATION NOTE BLUETOOTH SERIAL PORT PROFILE iwrap APPLICATION NOTE Thursday, 19 April 2012 Version 1.2 Copyright 2000-2012 Bluegiga Technologies All rights reserved. Bluegiga Technologies assumes no responsibility for

More information

Rayson. Bluetooth Module

Rayson. Bluetooth Module Rayson Class2 BC04-ext Module Features Bluetooth Module BTM-182 Outline Class2 module with printed pcb antenna Bluetooth standard Ver. 2.1 + EDR compliant. Low current consumption : Hold,Sniff,Park,Deep

More information

Cable Specifications and Information

Cable Specifications and Information APPENDIXA This appendix provides the connector and pinout information you need for making or purchasing cables used with Cisco VG350 Voice Gateway. To order cables from Cisco, see the Obtaining Technical

More information

RJ45 Shielded (standard) port pinout. CS9000, Jetstream 4000 + 8500, Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX

RJ45 Shielded (standard) port pinout. CS9000, Jetstream 4000 + 8500, Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX Shielded (standard) port pinout Pin Circuit Function 1 DCD Input Data Carrier Detect 2 DSR Output Data Set Ready 3 DTR Input Data Terminal Ready 4 S/GND Signal Ground 5 TXD Output Transmit Data 6 RXD Input

More information

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 1. Introduction Thank you for purchasing this 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter. It is an

More information

What is Easy-Radio? Devices Covered. Frequency Hopping Transceiver. Where x00 denotes frequency of operation. E.g. 400 = 433MHz

What is Easy-Radio? Devices Covered. Frequency Hopping Transceiver. Where x00 denotes frequency of operation. E.g. 400 = 433MHz What is Easy-Radio? Easy-Radio modules combine low power radio transmitters, receivers or transceivers with on-board microcontrollers to produce intelligent RF modules that provide simple to use wireless

More information

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

Product Information S N O. Portable VIP protection CCTV & Alarm System 2 Product Information S N O Portable VIP protection CCTV & Alarm System 2 G O V E R N M E N T A L S E C U R I T Y S O L U T I VIP KIT Rapid Deployment VIP Protection Kit The VIP KIT has been designed to

More information

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference : 9010709-03

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference : 9010709-03 MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE USER GUIDE Document reference : 9010709-03 If you have questions about the MDM192 or desire assistance, contact ETIC TELECOMMUNICATIONS at the following

More information

Part Number Description Packages available

Part Number Description Packages available Features 3 digital I/O Serial Data output Connects directly to RF Modules Easy Enc / Dec Pairing Function Minimal External Components Required Performs all encoding/decoding of data for Reliable Operation.

More information

Objectives. Basics of Serial Communication. Simplex vs Duplex. CMPE328 Microprocessors (Spring 2007-08) Serial Interfacing. By Dr.

Objectives. Basics of Serial Communication. Simplex vs Duplex. CMPE328 Microprocessors (Spring 2007-08) Serial Interfacing. By Dr. CMPE328 Microprocessors (Spring 27-8) Serial Interfacing By Dr. Mehmet Bodur Objectives Upon completion of this chapter, you will be able to: List the advantages of serial communication over parallel communication

More information

MFRD52x. Mifare Contactless Smart Card Reader Reference Design. Document information

MFRD52x. Mifare Contactless Smart Card Reader Reference Design. Document information Rev. 2.1 17. April 2007 Preliminary Data Sheet Document information Info Keywords Content MFRC522, MFRC523, MFRC52x, MFRD522, MFRD523, Mifare Contactless Smart Card Reader Reference Design, Mifare Reader

More information

Using Xbee 802.15.4 in Serial Communication

Using Xbee 802.15.4 in Serial Communication Using Xbee 802.15.4 in Serial Communication Jason Grimes April 2, 2010 Abstract Instances where wireless serial communication is required to connect devices, Xbee RF modules are effective in linking Universal

More information

Elettronica dei Sistemi Digitali Costantino Giaconia SERIAL I/O COMMON PROTOCOLS

Elettronica dei Sistemi Digitali Costantino Giaconia SERIAL I/O COMMON PROTOCOLS SERIAL I/O COMMON PROTOCOLS RS-232 Fundamentals What is RS-232 RS-232 is a popular communications interface for connecting modems and data acquisition devices (i.e. GPS receivers, electronic balances,

More information

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service

More information

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter Description: The NTE2053 is a CMOS 8 bit successive approximation Analog to Digital converter in a 20 Lead DIP type package which uses a differential

More information

A RF18 Remote control receiver MODULE

A RF18 Remote control receiver MODULE A RF18 Remote control receiver MODULE User Guide No part of this document may be reproduced or transmitted (in electronic or paper version, photocopy) without Adeunis RF consent. This document is subject

More information

How To Set Up A 366101 Modem (Marc) Model 366101 (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar

How To Set Up A 366101 Modem (Marc) Model 366101 (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar DIN Rail Mounted Leased Line Modem Users Manual 366-101 Rev. 2 Copyright 2008 Miille Applied Research Co., Inc. Houston, Texas This page is left blank intentionally Page i TABLE OF CONTENTS LIST OF FIGURES...

More information

Industrial Multi-port Serial Cards

Industrial Multi-port Serial Cards SUNIX I.N.C. Success Stories Industrial Multi-port Cards Multi-port Cards Introduction & Features Universal PCI Cards - Lite Interface Cards RS-232/422/485 Interface Cards PCI Express Cards - Lite Interface

More information

Application Note 83 Fundamentals of RS 232 Serial Communications

Application Note 83 Fundamentals of RS 232 Serial Communications Application Note 83 Fundamentals of Serial Communications Due to it s relative simplicity and low hardware overhead (as compared to parallel interfacing), serial communications is used extensively within

More information

Data sheet Wireless UART firmware version 4.02

Data sheet Wireless UART firmware version 4.02 Data sheet Wireless UART firmware version 4.02 BLUETOOTH is a trademark owned by Bluetooth SIG, Inc., U.S.A. and licensed to Free2move Rev: 22 December 2008 Table of contents 1 GENERAL INFORMATION...4

More information

ETRX3USB ETRX3USB-LRS ETRX3USB+8M ETRX3USB-LRS+8M PRODUCT MANUAL

ETRX3USB ETRX3USB-LRS ETRX3USB+8M ETRX3USB-LRS+8M PRODUCT MANUAL Telegesis TG-ETRX357USB-PM-014-102 ETRX3USB Product Manual 1.02 ZigBee USB STICKS: ETRX3USB ETRX3USB-LRS ETRX3USB+8M ETRX3USB-LRS+8M PRODUCT MANUAL 2013 Telegesis (UK) Ltd ETRX3USB Product Manual (Rev

More information

When we look at the connector pinout of the RS232 port, we see two pins which are certainly used

When we look at the connector pinout of the RS232 port, we see two pins which are certainly used 1 Null modem - an introduction Serial communications with RS232 1. One of the oldest and most widely spread communication methods in computer world. The way this type of communication can be performed

More information

GSM Interfacing Board

GSM Interfacing Board Campus Component Pvt. Ltd. DISCLAIMER Information furnished is believed to be accurate and reliable at the time of publication. However, Campus Component Pvt. Ltd. assumes no responsibility arising from

More information

PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999

PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999 232 232232 PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999 Guarantee. FULL 36 MONTHS GUARANTEE. We guarantee your interface card for a full 36 months from purchase, parts and labour, provided it has been

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

USB TO SERIAL ADAPTER

USB TO SERIAL ADAPTER USB TO SERIAL ADAPTER (Model: U232-P9V2) SPECIFICATIONS CONTENTS 1. GENERAL SPECIFICATIONS... 1 1.1 PRODUCT SURFACE... 1 1.2 PRODUCT DIMENSION... 2 1.3 PRODUCT FEATURES... 3 1.4 PRODUCT SPECIFICATIONS...

More information

Date Rev. Details Author

Date Rev. Details Author Jtech engineering ltd J - Te c h E n g i n e e ring, L t d. 11080 Bond Boulevard Delta BC V4E 1M7 Canada Tel: 604 543 6272 Fax: 604 543 6476 http://www.jtecheng.com AUTODIALER USER S MANUAL REVISION HISTORY

More information

RDF1. RF Receiver Decoder. Features. Applications. Description. Ordering Information. Part Number Description Packages available

RDF1. RF Receiver Decoder. Features. Applications. Description. Ordering Information. Part Number Description Packages available RDF1 RF Receiver Decoder Features Complete FM Receiver and Decoder. Small Form Factor Range up to 200 Metres* Easy Learn Transmitter Feature. Learns 40 transmitter Switches 4 Digital and 1 Serial Data

More information

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

TRP-C31M MODBUS TCP to RTU/ASCII Gateway TRP-C31M MODBUS TCP to RTU/ASCII Gateway User s Manual Printed Feb. 2007 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172

More information

Communication Unit 560CMU05 Data sheet

Communication Unit 560CMU05 Data sheet RTU560 product line Communication Unit 560CMU05 Data sheet E1 10/100 MB LAN E2 10/100 MB LAN CP1, CP2 RS232C or RS485 Ethernet Controller Ethernet Controller USART Processor bus MPU ELAN520 /Flash Memory

More information

Possible Applications

Possible Applications FRAUNHOFER Institute for integrated circuits iis DECT Wireless Voice and Data Communications DECT stands for Digital Enhanced Cordless Telecommunication and is an accepted standard in more than 100 countries.

More information

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...

More information

WIT910 900 MHz Spread Spectrum Wireless Industrial Transceiver

WIT910 900 MHz Spread Spectrum Wireless Industrial Transceiver 900 MHz Spread Spectrum Wireless Industrial Transceiver Integration Important Regulatory Information Cirronet Product FCC ID: HSW-910M IC 4492A-910M Note: This unit has been tested and found to comply

More information

Rayson Technology Co., Ltd.

Rayson Technology Co., Ltd. Rayson Bluetooth Module BC05-MM Class2 Stereo Module BTM-730 Features The module is a Max.4dBm( Class2 ) module. Fully Qualified Bluetooth v2.0+edr system. Integrated Switched-Mode Regulator. Integrated

More information

ULC Technology: High-performance gate array package using multiple metal layer CMOS technology featuring sub-micron channel lengths (0.

ULC Technology: High-performance gate array package using multiple metal layer CMOS technology featuring sub-micron channel lengths (0. SIR Endec for IrDA Applications Integrated Interface Circuits TOIM ULC Technology: High-performance gate array package using multiple metal layer CMOS technology featuring sub-micron channel lengths (0.

More information

Modbus Communications for PanelView Terminals

Modbus Communications for PanelView Terminals User Guide Modbus Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the Modbus versions of the PanelView terminals. This document

More information

DRM compatible RF Tuner Unit DRT1

DRM compatible RF Tuner Unit DRT1 FEATURES DRM compatible RF Tuner Unit DRT1 High- Performance RF Tuner Frequency Range: 10 KHz to 30 MHz Input ICP3: +13,5dBm, typ. Noise Figure @ full gain: 14dB, typ. Receiver Factor: -0,5dB, typ. Input

More information

Information. Communication for the open minded. Siemens Enterprise Communications www.siemens.com/open

Information. Communication for the open minded. Siemens Enterprise Communications www.siemens.com/open Information Cordless Telephones for HiPath Systems Alongside the system-specific HiPath telephones, Siemens offers additional cordless phones for operation with HiPath systems. These cordless phones will

More information

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet Guangzhou HC Information Technology Co., Ltd. Product Data Sheet Module Data Sheet Rev 1 1.0 1.01 2010/5/15 2011/4/6 DRAWN BY : Ling Xin MODEL : HC-05 CHECKED BY : Eric Huang Description: BC04 has external

More information

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet Guangzhou HC Information Technology Co., Ltd. Product Data Sheet Module Data Sheet Rev 1 1.0 1.01 2010/5/15 2011/4/6 DRAWN BY : Ling Xin MODEL : HC-05 CHECKED BY : Eric Huang Description: BC04 has external

More information

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

M68EVB908QL4 Development Board for Motorola MC68HC908QL4 M68EVB908QL4 Development Board for Motorola MC68HC908QL4! Axiom Manufacturing 2813 Industrial Lane Garland, TX 75041 Email: Sales@axman.com Web: http://www.axman.com! CONTENTS CAUTIONARY NOTES...3 TERMINOLOGY...3

More information

isco Connecting Routers Back to Back Through the AUX P

isco Connecting Routers Back to Back Through the AUX P isco Connecting Routers Back to Back Through the AUX P Table of Contents Connecting Routers Back to Back Through the AUX Ports...1 Introduction...1 Before You Begin...1 Conventions...1 Prerequisites...1

More information

User Manual IC-485AI 2002-09-27

User Manual IC-485AI 2002-09-27 User Manual IC-485AI Note: This equipment has been tested and found to comply ith the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable

More information

Cabling Guide for Console and AUX Ports

Cabling Guide for Console and AUX Ports Cabling Guide for Console and AUX Ports Contents Introduction Prerequisites Requirements Components Used Conventions Table of Routers with Console and AUX Ports Console Port Settings for Terminal Connection

More information

RC2200DK Demonstration Kit User Manual

RC2200DK Demonstration Kit User Manual Demonstration Kit User Manual Table of contents TABLE OF CONTENTS... 1 QUICK INTRODUCTION... 2 INTRODUCTION... 3 DEMONSTRATION BOARD... 4 POWER SUPPLY SECTION... 5 RS-232 INTERFACE... 6 CONNECTORS... 7

More information

Teleservice via RS232 interface XC100/XC200

Teleservice via RS232 interface XC100/XC200 User Manual 10/10 MN0500005Z-EN replaces 07/04 AWB74-1490GB Teleservice via RS interface XC100/XC00 All brand and product names are trademarks or registered trademarks of the owner concerned. Emergency

More information

Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information

Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information Cable Guide Click on the subject to view the information. Digi Cables Building Cables General Cable Information Digi Cables Click on the subject to view the information. Digi Connector Options Digi Connector

More information

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet Guangzhou HC Information Technology Co., Ltd. Product Data Sheet Rev 1 Module Data Sheet 1.0 2.0 2.1 2.2 2006/6/18 2006/9/6 2010/4/22 2011/4/6 DRAWN BY : Ling Xin MODEL : HC-06 CHECKED BY : Eric Huang

More information

ELAN DIGITAL SYSTEMS LTD. SL232 PC- CARD USER S GUIDE

ELAN DIGITAL SYSTEMS LTD. SL232 PC- CARD USER S GUIDE ELAN DIGITAL SYSTEMS LTD. LITTLE PARK FARM ROAD, SEGENSWORTH WEST, FAREHAM, HANTS. PO15 5SJ. TEL: (44) (0)1489 579799 FAX: (44) (0)1489 577516 e-mail: support@pccard.co.uk website: http://www.pccard.co.uk

More information

DK40 Datasheet & Hardware manual Version 2

DK40 Datasheet & Hardware manual Version 2 DK40 Datasheet & Hardware manual Version 2 IPC@CHIP DK40 Evaluation module Beck IPC GmbH http://www.bcl.de page 1 of 11 Table of contents Table of contents... 2 Basic description... 3 Characteristics...

More information

M80 EVB User Guide M80. Quectel Cellular Engine. EVB User Guide M80_EVB_UGD_V1.2 M80_EVB_UGD_V1.2-0-

M80 EVB User Guide M80. Quectel Cellular Engine. EVB User Guide M80_EVB_UGD_V1.2 M80_EVB_UGD_V1.2-0- M80 Cellular Engine EVB User Guide M80_EVB_UGD_V1.2 M80_EVB_UGD_V1.2-0- Document Title M80 EVB User Guide Version 1.2 Date 2012-08-13 Status Document Control ID Released M80_EVB_UGD_V1.2 General Notes

More information

M72. Quectel Cellular Engine. EVB User Guide M72_EVB_UGD_V1.0

M72. Quectel Cellular Engine. EVB User Guide M72_EVB_UGD_V1.0 M72 Quectel Cellular Engine EVB User Guide M72_EVB_UGD_V1.0 Document Title EVB User Guide Version 1.0 Date 2011-05-18 Status Document Control ID Release M72_EVB_UGD_V1.0 General Notes Quectel offers this

More information

VMR6512 Hi-Fi Audio FM Transmitter Module

VMR6512 Hi-Fi Audio FM Transmitter Module General Description VMR6512 is a highly integrated FM audio signal transmitter module. It integrates advanced digital signal processor (DSP), frequency synthesizer RF power amplifier and matching network.

More information

One Port Serial Server Users Manual Model ESP901, ESP901E

One Port Serial Server Users Manual Model ESP901, ESP901E One Port Serial Server Users Manual Model ESP901, ESP901E Documentation Number: ESP901-2303 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350

More information

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals

More information

Introduction Ericsson Handheld Telephone 1341-B

Introduction Ericsson Handheld Telephone 1341-B Ericsson Handheld Telephone 1341-B 2 Contents General 5 The Mobile Telephone Network 6 Base Station and Cell 7 Radio Channels 7 Radio Coverage 8 Transmission Control and Communication 9 Quality Control

More information

Serial Communications

Serial Communications April 2014 7 Serial Communications Objectives - To be familiar with the USART (RS-232) protocol. - To be able to transfer data from PIC-PC, PC-PIC and PIC-PIC. - To test serial communications with virtual

More information

[WIR-1186] 865MHz-869MHz Wireless Module(version 3.0) (3.3V)

[WIR-1186] 865MHz-869MHz Wireless Module(version 3.0) (3.3V) [WIR-1186] 865MHz-869MHz Wireless Module(version 3.0) (3.3V) http://www.robokitsworld.com Page 1 Contents 1) Features:... 4 2) Block Diagram... Error! Bookmark not defined. 3) Description:... 4 4) PIN

More information

PACKAGE OUTLINE DALLAS DS2434 DS2434 GND. PR 35 PACKAGE See Mech. Drawings Section

PACKAGE OUTLINE DALLAS DS2434 DS2434 GND. PR 35 PACKAGE See Mech. Drawings Section PRELIMINARY DS2434 Battery Identification Chip FEATURES Provides unique ID number to battery packs PACKAGE OUTLINE Eliminates thermistors by sensing battery temperature on chip DALLAS DS2434 1 2 3 256

More information

LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION

LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION RS-422/485 PCI Card User Manual English No. 51200 (2 Port) No. 51202 (4 Port) No. 51204 (8 Port) www.lindy.com LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - SECOND EDITION (Nov 2005) 1.0 Introduction

More information

Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200

Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200 Linux Device Server IGW/922 with DIL/NetPC ADNP/9200 Hardware Reference SSV Embedded Systems Heisterbergallee 72 D-30453 Hannover Phone: +49 (0)511/40 000-0 Fax: +49 (0)511/40 000-40 E-mail: sales@ist1.de

More information

Bluetooth to Serial Adapter

Bluetooth to Serial Adapter Bluetooth to Serial Adapter Third Edition, Oct 2007 Version 3.0 771-BTS1009C3-001 Contents 1.0 Features....P.2 2.0 Package Content....P.2 3.0 Hard Drives Requirement.P.2 4.0 Specifications.P.3 5.0 Pin

More information

ESPA 4.4.4 Nov 1984 PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION

ESPA 4.4.4 Nov 1984 PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION 2.1 CHARACTER STRUCTURE 2.2 THE CHARACTER SET 2.3 CONTROL CHARACTERS 2.3.1 Transmission control

More information

Cable Pinouts. SRP I/O Module

Cable Pinouts. SRP I/O Module Cable Pinouts C This appendix lists the cables and connector pinout assignments for the cables used with the ERX-700 series and ERX-1400 series. Topic Page SRP I/O Module C-1 CT1 and CE1 I/O Modules C-4

More information

Installation Guide. AXIS 2191 Audio Module Sight, Speech and Sound over IP!

Installation Guide. AXIS 2191 Audio Module Sight, Speech and Sound over IP! Installation Guide AXIS 2191 Audio Module Sight, Speech and Sound over IP! AXIS 2191 Installation Guide Page 1 of 7 The AXIS 2191 Audio Module The AXIS 2191 Audio Module is an add-on device that provides

More information

- 35mA Standby, 60-100mA Speaking. - 30 pre-defined phrases with up to 1925 total characters.

- 35mA Standby, 60-100mA Speaking. - 30 pre-defined phrases with up to 1925 total characters. Contents: 1) SPE030 speech synthesizer module 2) Programming adapter kit (pcb, 2 connectors, battery clip) Also required (for programming) : 4.5V battery pack AXE026 PICAXE download cable Specification:

More information

Hardware Specifications of V2AF Series Hybrid Card Reader

Hardware Specifications of V2AF Series Hybrid Card Reader B (1/ 14) Hardware Specifications of V2AF Series Hybrid Card Reader Rev. A Sep. 28, 1999 Rev. B Feb. 22, 2000 Card Business Promotion Division OMRON Corporation 1999 All Rights Reserved O M R O N B (2/

More information

XPort Universal Demo Board User Guide

XPort Universal Demo Board User Guide XPort Universal Demo Board User Guide Part Number 900-563 Revision A September 2009 Copyright and Trademark Contacts 2009 Lantronix. All rights reserved. No part of the contents of this book may be transmitted

More information

Technical description MX-1 VB Edge

Technical description MX-1 VB Edge 1 (7) Technical description MX-1 VB Edge 2 (7) Table of Contents 1 General description...3 2 Connectors...4 3 ON/OFF operation...5 4 Power...5 5 LED indicators...6 6 Enclosure...6 7 Mounting...6 8 and

More information

SR450 RECEIVER OPERATING INSTRUCTIONS 1892 1128

SR450 RECEIVER OPERATING INSTRUCTIONS 1892 1128 SR450 RECEIVER OPERATING INSTRUCTIONS 1892 1128 These operating instructions are intended to provide the user with sufficient information to install and operate the module correctly. The Wood & Douglas

More information

RECOMMENDATION ITU-R F.1113. (Question ITU-R 157/9) b) that systems using this mode of propagation are already in service for burst data transmission,

RECOMMENDATION ITU-R F.1113. (Question ITU-R 157/9) b) that systems using this mode of propagation are already in service for burst data transmission, Rec. ITU-R F.1113 1 RECOMMENDATION ITU-R F.1113 RADIO SYSTEMS EMPLOYING METEOR-BURST PROPAGATION (Question ITU-R 157/9) (1994) Rec. ITU-R F.1113 The ITU Radiocommunication Assembly, considering a) that

More information

MG2639 Module Hardware Design User Manual. Version:V1.0

MG2639 Module Hardware Design User Manual. Version:V1.0 MG2639 Module Hardware Design User Manual Version:V1.0 Copyright Statement Copyright 2010 by ZTE Corporation All rights reserved. No part of this publication may be excerpted, reproduced, translated or

More information

WIRELESS MAGNETIC CONTACT

WIRELESS MAGNETIC CONTACT WIRELESS MAGNETIC CONTACT The magnetic contact wireless MAG HCS is a sensor able to detect opening or closing doors or windows and transmits via radio a alarm signal. It is composed of two distinct elements:

More information

Quick Start Guide. MRB-KW01 Development Platform Radio Utility Application Demo MODULAR REFERENCE BOARD

Quick Start Guide. MRB-KW01 Development Platform Radio Utility Application Demo MODULAR REFERENCE BOARD Quick Start Guide MRB-KW01 Development Platform Radio Utility Application Demo MODULAR REFERENCE BOARD Quick Start Guide Get to Know the MRB-KW01x Module UART Selector ANT 1 RFIO (TX/RX) USB 2.0 Serial

More information

M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007

M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007 M2M 3350 GSM/GPRS Modem User s Manual & Reference Guide Revision 1 June 2007 1999-2007 by Laipac Technology, Inc. All rights reserved The Specifications and information regarding the products in this manual

More information

VOICE RECORDING SYSTEM ISDN PRI / BRI

VOICE RECORDING SYSTEM ISDN PRI / BRI Sense Box VOICE RECORDING SYSTEM ISDN PRI / BRI / Analog SUB-SYSTEM ISDN2, ISDN30 Sense Box USER MANUAL TABLE OF CONTENTS 1. STATUTORY INFORMATION... 3 1.1 SAFETY WARNING... 3 1.2 SAFETY EXTRA LOW VOLTAGE

More information

IPG/7700 Hardware Manual SYSTECH. Document number 80-001099-7 Revision A

IPG/7700 Hardware Manual SYSTECH. Document number 80-001099-7 Revision A IPG/7700 Hardware Manual SYSTECH C O R P O R A T I O N Document number 80-001099-7 Revision A Created 2010, and Protected Under the U.S. Copyright Act of 1976. Copyright 2010, SYSTECH Corporation All Rights

More information

Security & Chip Card ICs SLE 44R35S / Mifare

Security & Chip Card ICs SLE 44R35S / Mifare Security & Chip Card ICs SLE 44R35S / Mifare Intelligent 1 Kbyte EEPROM with Interface for Contactless Transmission, Security Logic and Anticollision according to the MIFARE -System Short Product Info

More information

Future Technology Devices International Ltd

Future Technology Devices International Ltd Future Technology Devices International Ltd Datasheet Chipi-X Cable Chipi-X is a USB to full-handshake RS232 cable with a male DB9 connector. This cable is available with or without an enclosure. 1 Introduction

More information