Displays 2 x 24 Character Serial Display Module
|
|
|
- Willis White
- 9 years ago
- Views:
Transcription
1 MAKING MODERN LIVING POSSIBLE Technical Information Displays 2 x 24 Character Serial Display Module powersolutions.danfoss.com
2 Revision history Table of revisions Date Changed Rev November 2015 Converted to Danfoss layout 0101 August 2010 Replacement part numbers for modules 0100 November 2006 First edition Rev 0101 November 2015
3 Contents General information Technical data Product installation Product overview... 4 Features...4 Available models... 4 Theory of operation...5 Character set... 6 Accessories...7 Electrical...8 Environmental... 8 Dimensions... 9 Wiring connections Machine wiring guidelines Rev 0101 November
4 General information Product overview The Danfoss 2 x 24 serial display module is designed for the demanding operating conditions and environments common to mobile machine applications. The display module integrates an industry standard New Twisted Nematic (NTN) LCD alpha numeric display glass with robust high impact plastic packaging and interface electronics allowing installation in no cab and open cab machines. Superior readability in all ambient light conditions is accomplished through the use of a transflective, backlit type of display with dark characters on a green background. An adjustable viewing angle option (controlled via software) allows machine operators to adjust display contrast to compensate for changing light conditions and operator position. Character clarity is enhanced by a 5 x 7 dot matrix character. 2 x 24 display modules are designed to be used in conjunction with Danfoss microcontrollers via RS232 serial communication. Danfoss electronics embedded in the display module convert serial character transmission to the parallel format required by the display. Features Cost effective alpha numeric display Rugged mechanical design for mobile applications IP 65 rating above panel rating; resistant to high pressure wash down Built in Danfoss serial to parallel card allows easy communication with display driver LED backlight for very low light conditions Dark characters on green background; excellent visibility in a wide variety of ambient light conditions Suitable for 12 and 24 volt systems; option for 5 volt power Extended operating temperature range Operates in conjunction with most Danfoss microcontrollers Fixed and operator adjustable viewing angles Available models 2 x 24 Character Serial Display modules part numbers Obsolete Replaced by Supply voltage and viewing position Recommended microcontroller to 15 Vdc; direct horizon view, adjustable S2X, MC to 15 Vdc; 30 to 45 above horizon, adjustable S2X, MC to 15 Vdc; Direct horizon view, not adjustable S2X, MC to 32 Vdc; Direct horizon view, adjustable S1X, MC to 32 Vdc; 30 to 45 above horizon, adjustable S1X, MC to 32 Vdc; Direct horizon view, not adjustable S1X, MC Rev 0101 November 2015
5 General information Theory of operation Danfoss 2 x 24 Display Modules are designed to operate in conjunction with Danfoss microcontrollers. The generation of display messages is typically an integral part of the application program running in the microcontroller. Character information is transmitted from the microcontroller to the display module via RS232 standard signal levels and protocol operating at 9600 Baud. Danfoss proprietary interface electronics embedded in the display module converts microcontroller serial data to the parallel data format required by the LCD display driver. The Display Module is a receive only device and does not return any information to the microcontroller. Display readability is influenced by two parameters: The operator s spatial relationship to the display and the display viewing angle (also referred to as viewing cone). Spatial relationship can be described as either direct horizon view or 30 to 45 degrees above horizon. See the following illustration. Display viewing angle can be either fixed or variable. Fixed viewing angle displays have a factory set voltage that cannot be adjusted after manufacture. Variable viewing angle (also referred to as contrast) is controlled by varying the voltage applied to the capacitive fluid in the display glass which changes the alignment of display particles. Variable displays allow the user to adjust display glass contrast control voltage in a step-wise manner through software control from the microcontroller. The display voltage control range is controlled over 100 steps. Variable displays are typically used in applications where there is no cab and variable lighting conditions. Displays with variable viewing angles will default to the most recent control voltage at power-up. Operators spacial relationship to the display and the display viewing angle 1 2 kwa to 45 horizontal view 2 Direct horizontal view Rev 0101 November
6 General information Character set Each of the 48 display module character locations contain a five by seven dot matrix. The display supports the following standard and special LCD character sets: Standard character set Danfoss special 0 x 00 = 0 x 01 = 0 x 02 = 0 x 03 = 0 x 04 = 0 x 05 = 0 x 06 = 0 x 07 = Display character locations kwa kwa Rev 0101 November 2015
7 General information Accessories Mating connector cable assemblies Part number Microcontroller Description S2X, MC300 Molded right angle display mating connector and 6 pin microcontroller MS Pigmy mating connector, cm [84 in] length. K19853 S1X and MC400 Molded right angle display mating connector and bare tinned leads cm [84 in] length Rev 0101 November
8 Technical data Electrical Electrical characteristics Part number Supply voltage Current consumption RS232 baud rate , , to 15 Vdc 200 ma , , to 32 Vdc 200 ma 9600 Transient suppression Protected against static discharge Environmental IP 65 Rating above panel. Withstands high pressure wash and high humidity typical in mobile machine operations. Environmental characteristics Operating temperature Storage temperature -30 C to +70 C [-22 F to +158 F] -20 C to +70 C [-4 F to +158 F] Rev 0101 November 2015
9 Product installation Dimensions installation dimensions in millimeters [inches] [0.51] [1.27] [3.91] [0.25] 7.11 [0.28] [2.375] [9.25] [5.00] 2 X [.47] [2.94] [2.375] [1.47] [0.19] [1.88] [5.00] [8.75] [2.375] [2.00] 2 kwa X 4.83 [.190] DIA THRU and CBORE 9.14 [.36 ] DIA X 4.06 [.16] DP 2 #8-32UNC-2B THREADS Rev 0101 November
10 Product installation Wiring connections 8 [.31] x 6.3 [.25] BAYONET electrical connectors WECO electrical connectors Part number 900-SUN kwa to 15 Vdc power supply models Pin Function 1 Ground 2 Ground 3 Not used 4 Not used 5 RS232 IN 6 5 to 15 V DC device power 7 Alternate 5 to 15 V DC device power 8 Alternate device ground 6 pin CONXALL MULTI-CON-X Part number kwa to 32 Vdc power supply models Pin Function 1 Ground 2 Ground 3 9 to 32 Vdc device power * 4 Ground 5 RS232 IN 6 9 to 32 V DC device power 7 Alternate 9 to 32 V DC device power 8 Alternate device ground * Only one power connection is required. C Caution Potential property damage. Connect all ground pins on 6 pin connector to vehicle ground Rev 0101 November 2015
11 Product installation Machine wiring guidelines Protect wires from mechanical abuse, run wires in flexible metal or plastic conduits. Use 85 C (185 F) wire with abrasion resistant insulation and 105 C (221 F) wire should be considered near hot surfaces. Use a wire size that is appropriate for the module connector. Separate high current wires such as solenoids, lights, alternators or fuel pumps from sensor and other noise-sensitive input wires. Run wires along the inside of, or close to, metal machine surfaces where possible, this simulates a shield which will minimize the effects of EMI/RFI radiation. Do not run wires near sharp metal corners, consider running wires through a grommet when rounding a corner. Do not run wires near hot machine members. Provide strain relief for all wires. Avoid running wires near moving or vibrating components. Avoid long, unsupported wire spans. Ground electronic modules to a dedicated conductor of sufficient size that is connected to the battery (-). Power the sensors and valve drive circuits by their dedicated wired power sources and ground returns. Twist sensor lines about one turn every 10 cm (4 in). Use wire harness anchors that will allow wires to float with respect to the machine rather than rigid anchors. C Caution Unused pins on mating connectors may cause intermittent product performance or premature failure. Plug all pins on mating connectors. W Warning Unintended movement of the machine or mechanism may cause injury to the technician or bystanders. Improperly protected power input lines against over current conditions may cause damage to the hardware. Properly protect all power input lines against over-current conditions Rev 0101 November
12 Products we offer: Bent Axis Motors Closed Circuit Axial Piston Pumps and Motors Displays Electrohydraulic Power Steering Electrohydraulics Hydraulic Power Steering Integrated Systems Joysticks and Control Handles Microcontrollers and Software Open Circuit Axial Piston Pumps Orbital Motors PLUS+1 GUIDE Proportional Valves Sensors Steering Transit Mixer Drives Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and electronic components. We specialize in providing state-of-the-art technology and solutions that excel in the harsh operating conditions of the mobile off-highway market. Building on our extensive applications expertise, we work closely with our customers to ensure exceptional performance for a broad range of off-highway vehicles. We help OEMs around the world speed up system development, reduce costs and bring vehicles to market faster. Danfoss Your Strongest Partner in Mobile Hydraulics. Go to for further product information. Wherever off-highway vehicles are at work, so is Danfoss. We offer expert worldwide support for our customers, ensuring the best possible solutions for outstanding performance. And with an extensive network of Global Service Partners, we also provide comprehensive global service for all of our components. Please contact the Danfoss Power Solution representative nearest you. Comatrol Schwarzmüller-Inverter Turolla Hydro-Gear Daikin-Sauer-Danfoss Local address: Danfoss Power Solutions (US) Company 2800 East 13th Street Ames, IA 50010, USA Phone: Danfoss Power Solutions GmbH & Co. OHG Krokamp 35 D Neumünster, Germany Phone: Danfoss Power Solutions ApS Nordborgvej 81 DK-6430 Nordborg, Denmark Phone: Danfoss Power Solutions Trading (Shanghai) Co., Ltd. Building #22, No Jin Hai Rd Jin Qiao, Pudong New District Shanghai, China Phone: Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved Rev 0101 November Danfoss A/S, 2015
Joystick PVRES and PVREL. Technical Information
Joystick PVRES and PVREL Technical Information Contents Revision History PVRES General PVRES Accessories PVREL General Table of Revisions Date Page Changed Rev Mar 2003 All First edition AA May 2010 16
PLUS+1 GUIDE Software. PLUS+1 Compliant H1 Filter Bypass Function Block User Manual COMPLI ANT. 158.2 mm 6.23. 144.5 mm 5.69. 2x 25.2 mm [1.
PLUS+1 GUIDE Software PLUS+1 Compliant H1 Filter Bypass Function Block 158.2 mm 6.23 144.5 mm 5.69 142.0 mm [5.59] 2x 25.2 mm [1.0] 97.0 mm [3.82] TM 2x 7.0 [.28] MOUNTING DIRECTION #2 COMPLI ANT PIN #1
Smart. Productivity and performance The PLUS+1 control platform. powersolutions.danfoss.com. control systems MAKING MODERN LIVING POSSIBLE
MAKING MODERN LIVING POSSIBLE Productivity and performance The PLUS+1 control platform Smart control systems bring your machines faster, more efficiently to market powersolutions.danfoss.com Taking mobile
The PLUS+1 Control Platform. Productivity and Performance
The PLUS+1 Control Platform Productivity and Performance Taking Mobile Machine Control to the Next Level The OEM design environment continues to become more challenging, every day, every year. Vehicle
JS2000 Joystick. Technical Information. Reverse. Right. Left. Forward
Technical Information Reverse Right Left Forward Revision history Revision date Page Change Remarks 03/24/2005 Initial release 2005 Sauer-Danfoss. All rights reserved. Printed in U.S.A. Sauer-Danfoss accepts
Series TMM Axial Piston Motor. Technical Information
Series TMM Axial Piston Motor Technical Information General Description GENERAL DESCRIPTION These motors are designed primarily to be combined with other products in closed circuit systems to transfer
The Do s and Don ts of Pressure Transducers
The Do s and Don ts of Pressure Transducers ABSTRACT When specifying a pressure transducer for a process measurement, a number of items have to be considered. Some of the more important ones are discussed
Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.
Preliminary TECHNICAL DATASHEET #TDAX020700 HYDRAULIC VALVE CONTROLLER 24 I/O 5 Analog and 6 Digital Inputs 1 Temperature Sensor and 1 RPM Sensor Interface 2 PWM Inputs 6 Proportional and 4 ON/OFF Current
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Ordering Part Numbers:
TECHNICAL DATASHEET #TDAX021500 HYDRAULIC FAN CONTROLLER Application Platform 3 erature Sensors 4 Digital Command Interfaces 1 PWM Input and 1 Analog Input 1 Proportional or ON/OFF Current Output RS232
Subminiature Load Cell Model 8417
w Technical Product Information Subminiature Load Cell 1. Introduction... 2 2. Preparing for use... 2 2.1 Unpacking... 2 2.2 Using the instrument for the first time... 2 2.3 Grounding and potential connection...
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Speed sensor MiniCoder GEL 247
Speed sensor MiniCoder GEL 47 Flange assembly Technical information version 08.0 The MiniCoder family from Lenord + Bauer offers spacesaving solutions for the contactless measurement of rotational movements
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
with Electronic Assistant
TECHNICAL DATASHEET #TDAX100200 BLDC Motor Drive Drives a 12V, 24V or 48V BLDC motor Bidirectional, up to 25A Smooth speed control using Hall Sensors CAN (SAE J1939) with Electronic Assistant Features:
Mobile Case Studies in Success
Mobile Case Studies in Success Your Application, Our Responsibility. Advanced Fluid Systems solution oriented approach thinks beyond the hydraulic components and assemblies to understand your entire application
Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications
Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications Industrial and transportation applications require robust connections with superior
T7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.
TECHNICAL DATASHEET #TDAX06070X Triaxial Inclinometer with Gyro ±180⁰ Pitch/Roll Angle Pitch Angle Rate Acceleration SAE J1939, Analog Output or RS-232 Options 2 M12 Connectors, IP67 with Electronic Assistant
Specification of 5 Wire Analog Touch Panel
Specification of 5 Wire Analog Touch Panel 5 WIRE ANALOG RESISTIVE TOUCH PANEL A. Application This specification applies to the 5 Wire Analog Resistive Touch Panel. B. Environmental Conditions 1. Operating
MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.
DP6XX Series Graphical Terminals. Technical Information
DP6XX Series Graphical Terminals Technical Information Contents Contents Contents... 2 About This Manual About This Manual... 4 DP2XX Graphical Display Family... 4 Safety and Liability Information User
Operating Instructions
CS101 CarSense Vehicle Motion Detector Operating Instructions CAUTIONS AND WARNINGS Never use the CS101 as a safety reversing or presence detection system. The CS101 requires that a vehicle be moving for
Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
ABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
www.curtisinstruments.com
CANBUS I/O EXPANSION MODULE MODELS 56 / 56P FEATURES Eighteen multi-purpose I/O pins provide simple, flexible vehicle control system expansion. Two high-frequency (A, A) PWM driver outputs support a variety
Instruction book IQAN-MDM. Publ. no. HY17-8328/UK Edition June, 2007
Instruction book IQAN-MDM Publ. no. HY17-8328/UK Edition June, 2007 Contents 1 Introduction...............................................................3 Safety symbols................................................................
How To Set Up An Inverter
MAKING MODERN LIVING POSSIBLE SOLAR INVERTERS Installation Guide GSM Option Kit FLX series www.danfoss.com/solar Safety Safety Safety Message Types WARNING Safety information important for human safety.
psens Pressure Measurement
Mobile Machine Control Solutions psens Pressure Measurement Reliable Compact Versatile Unique Measurement Accuracy psens. Pressure Sensors from Hirschmann MCS Hirschmann pressure transducers are an ideal
3500/93 System Display
3500/93 System Display Bently Nevada* Asset Condition Monitoring Description The 3500/93 System Display is designed to meet the requirements of American Petroleum Institute (API) Standard 670 and provide
CYMAQ Marking System AS200 + DS7050 N-14
CYMAQ Marking System AS200 + DS7050 N-14 Serial Number: 13716 CYMAQ www.cymaq.com INDEX 1. PRESENTATION AND GENERAL POINTS 1.1. General Points 1.2. Identification plate 2. MACHINE CHARACTERISTICS 2.1.
WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100
WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.
* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2
COMMERCIAL INSTALL GUIDE 2 Contents How to Use This Guide: The first section of this guide is designed to assist you with the installation of your DECK Monitoring hardware. The revenue grade meter and
Cat Electronic Technician 2015C v1.0 Product Status Report 2/16/2016 9:19 AM
Cat Electronic Technician 2015C v1.0 Product Report 2/16/2016 9:19 AM Product Report Product ID Comments Unavailable H2A00626 3054 M313C (CRX13565) H2A00626 Engine Serial Number CRX13565 ECM Serial Number
330505 Low Frequency Velocity Sensor
330505 Low Frequency Velocity Sensor Bently Nevada* Asset Condition Monitoring Description The Bently Nevada Low Frequency Velocity Sensor is designed to measure absolute (relative to free space) bearing
EMBEDDED ACCESS CONTROL Hardware Installation Guide
EMBEDDED ACCESS CONTROL Hardware Installation Guide Lenel goentry Hardware Installation Guide, product version 1.00. This guide is item number DOC- ENHW-ENU, revision 1.003, April 2009 Copyright 2009 Lenel
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring
330450 High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring Description The standard 330400 Accelerometer has a limited temperature range it can be exposed to, due to its signal
Mobile Data Power Model: MDP-25
Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss
Standard WIRED Installation Guide
Standard WIRED Installation Guide Version 1.0.1 1 Installing the STANDARD WIRED DEVICE The installation of the STANDARD WIRED DEVICE and its antennas can have a major impact on the STANDARD WIRED DEVICE
Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection
w Technical Product Information Precision Miniature Load Cell with Overload Protection 1. Introduction The load cells in the model 8431 and 8432 series are primarily designed for the measurement of force
Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.
Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power
Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual
Doc.No. NDP 192U-02 Electric Pump Controller CE-124P Instruction Manual 1. Parts Name and Function 1) POWER LED Indicate that CE-124P is powered up. 2) START/STOP KEY (SELECTOR KEY) Used to start and stop
VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control
VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1
No. : EX##-OMF0004 OPERATION MANUAL EX12#-SMB1 Contents 1. Safety instructions ------------------------------------------------------ P3 2. Notes ------------------------------------------------------
Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface
Options for ABB drives, converters and inverters User s manual FDPI-02 diagnostics and panel interface Table of contents Table of contents 3 1. FDPI-02 diagnostics and panel interface Safety..............................................
SU90 RS232 Interface Magnetic card reader
Shanghai Huayuan Smart Information Technology Co., Ltd 上 海 华 苑 斯 码 特 信 息 技 术 有 限 公 司 ROOM 707-709, JINDU MANSION, NO.277 WUXING RD. SHANGHAI,200030,CHINA 上 海 市 吴 兴 路 277 号 锦 都 大 厦 707-709 TEL: 86 21 64458052
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
Contactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
Before installation it is important to know what parts you have and what the capabilities of these parts are.
INSTALLATION GUIDE Before installation it is important to know what parts you have and what the capabilities of these parts are. The Recon XZT is the smallest and most powerful gauge of its kind. With
NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing
NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing Introduction: NS-205-IP67 Ethernet Switches are designed for use in industrial waterproof/harsh environments. The rugged packaging
Custom Cable Assemblies for Medical Applications and more.
Custom Cable Assemblies for Medical Applications and more. National Cable Molding is one of the United States premier suppliers of custom molded electrical assemblies for medical applications. Our capability
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
Orbit PCI Mk 2 Network Card. User Manual. Part No. 502566 Issue 4
Orbit PCI Mk 2 Network Card User Manual Part No. 502566 Issue 4 Information in this document is subject to change without notice. Companies, names and data used in examples herein are fictitious unless
Mini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
Series 510 Submersible Level Transmitters
Series 510 Submersible Level Transmitters The Series 510 Submersible Level Transmitters are solid state instruments designed for direct submergence into many types of liquid for quick, accurate and reliable
MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)
Installation and Maintenance Manual IM 852 Group: Controls Part Number: IM 852 Date: June 2007 Supercedes: New MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
Industrial Bar Code Scanners
DS4800 Industrial Bar Code Scanners Enhanced Connectivity Ease of use Configuration SW Tool ACR4 technology Smart focus adjustment APPLICATIONS Automated warehousing Reading on pallets Picking systems
Data Sheet PS1B Pressure Switch
Data Sheet PS1B Pressure Switch Main Features Pressure Ranges 0 to 6 up to 0 to 600 bar (gage) Electrical Connection G 1/4 A DIN 3852-E or -A Pressure Connection Output Signal M12-4 Pin 4-20 ma, Programmable
KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER
KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER DEALER SERVICE AND INSTALLATION MANUAL KIT NO. 00016-30915 Contents PARTS LIST... 2 PARTS ILLUSTRATIONS... 2 VEHICLE PREPARATION... 3 INSTALLING
Laserlyte-Flex Alignment System
Laserlyte-Flex Alignment System LaserLyte-Flex The LaserLyte-Flex Alignment System is a unique, interchangeable, low cost plug and play laser system. Designed specifically for aligning and positioning
sensors Miniature Sensors - S100 The universal miniature photoelectric sensor
Miniature Sensors - S1 The universal miniature photoelectric sensor Two threaded front mounting holes Two slotted rear mounting holes Anti-tampering sensor (no adjustment) Standard optic functions and
Install the DeviceNet Module using the following procedure:
Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from
Photovoltaic Solar Energy Unit EESFB
Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality
Hydraulic Control Technology for Wind Turbine Generators
Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Hydraulic Control Technology for Wind Turbine Generators Extra
How To Read A Pipe From A Sensor
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
TECHNICAL DATASHEET #TD1000AX DUAL SOLENOID MULTIFUNCTION VALVE DRIVER With Joystick, Potentiometer and Control System Interface P/N: DSDA-SMB Series
TECHNICAL DATASHEET #TD1000AX DUAL SOLENOID MULTIFUNCTION VALVE DRIVER With Joystick, Potentiometer and Control System Interface P/N: DSDA-SMB Series Description: The Dual Solenoid Multifunction Valve
INSTALLATION & SERVICE MANUAL. Display Panel
INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed
Laser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
omega.com ΩOMEGA RS232 Multi-Drop www.omega.com FMA1600-MDB Multi-Drop Box
omega.com ΩOMEGA RS232 Multi-Drop www.omega.com FMA1600-MDB Multi-Drop Box 1 3/29/2010 Rev.0 DOC-OMEGABB9MAN 2 Introduction FMA1600-MDB Multi-Drop Box Operating Bulletin The FMA1600-MDB Multi-Drop Box
Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3
Typical Applications Typical Applications Construction Transmitter Assembly Pipe & cable locator transmitter Transmitting active signals for the location of buried pipes and cables High impact ABS Weight
DK40 Datasheet & Hardware manual Version 2
DK40 Datasheet & Hardware manual Version 2 IPC@CHIP DK40 Evaluation module Beck IPC GmbH http://www.bcl.de page 1 of 11 Table of contents Table of contents... 2 Basic description... 3 Characteristics...
CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.
7I29 MANUAL Rev 1.5 CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB. THE 7I29 IS INTENDED FOR USE BY OEMS THAT WILL INTEGRATE IT INTO A SYSTEM WITH INTERLOCKS AND
How To Build A Powerline Box Powerline Generator
Quick Reference Guide DYNAMIC Series Dynamic Series is a broad product family that provides connector solutions ranging from signal level circuitry through power circuit connectivity in a ruggedized, industrialized
What are the basic electrical safety issues and remedies in solar photovoltaic installations?
What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic
In-Sight Hardware specifications
specifications In-Sight 5000, 5100, 5400, 5400S, 5400C, 5401, and 5403 4020 Linz/Austria Pummererstr. 36 Tel.: +43-(0)70-7646-0* www.schmachtl.at Memory Job/Program 16MB non-volatile flash memory; Unlimited
PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.
Quick-Connect Cables with Connectors PA Simplifies sensor wiring. Wide variety of connectors attached to cables. Series No wiring or staking work needed Shorter replacement time in unlikely event of sensor
How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)
MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
WEB log. Device connection plans
WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20151210* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER
TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)
TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions
TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TRACETEK TraceTek TTDM Replacement Parts General Information These instructions detail the steps to
Operating Instructions
VMD202 Vehicle Motion Detector Operating Instructions CAUTIONS AND WARNINGS Never use the VMD202 as a safety reversing or presence detection system. The VMD202 requires that a vehicle be moving for detection.
Prep Plus Bulletin. Bulletin No. 004 August 15, 2007
Prep Plus Bulletin Marine Division Bulletin No. 004 August 15, 2007 Boat Builder Bulletin The 2008 engine model SDS communication connectors have been changed from an 8 pin round housing to a 4 pin square
Waekon Gold. Test Lead Master Kit. Tight Spot Test Lead Kit. Micro Mate Terminal Adapter Set. Magnetic Test Lead Ground Lug
Sharp, adjustable depth contact tip to penetrate corrosion or metal coatings for a good connection. Limited Lifetime warranty. 1) Universal Magnetic Ground Lug Stop searching for a good place to clip your
Original instructions Tina 3A/Aps Adaptor unit
Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
FACTORY AUTOMATION LGS SERIES INTELLIGENT
FACTORY AUTOMATION LGS Series INTELLIGENT light Grid A LIGHT GRID WITH THE RIGHT TOUCH Lightning fast, adaptable, and cost-effective, the new LGS series light grids open the door to a wider range of detection
Analog Amplifier Rexroth RA: Easy, user-friendly control of pumps and valves
Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Analog Amplifier Rexroth RA: Easy, user-friendly control of pumps and valves The Drive & Control Company
Microcontroller Display Interfacing Techniques
Display Interfacing Techniques Document Revision: 1.01 Date: September 13, 2006 16301 Blue Ridge Road, Missouri City, Texas 77489 Telephone: 1-713-283-9970 Fax: 1-281-416-2806 E-mail: [email protected] Web:
Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors
Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors E-Series Model ER Analog and Start/Stop Outputs SENSORS Document Part Number: 550996 Revision E Data Sheet Model ER position
Rosemount 333 HART Tri-Loop
Product Data Sheet September 2014 00813-0100-4754, Rev GA Rosemount 333 HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three additional analog signals Easy to configure
Safety at a high level!
SIKA Level Switch SIKA Level Switch Safety at a high level! Convincing Advantages easy and reliable method to monitor fluid levels proven float principle easy side installation using threads ¾" or ½" BSP
OIL PRESS 71.8 PSI FUEL. Cloud based, diagnostic, engine monitoring and reporting system. www.faria-instruments.com www.beede.com
OIL PRESS 71.8 PSI Cloud based, diagnostic, engine monitoring and reporting system www.faria-instruments.com www.beede.com Start Updating Send Data The Faria EntelNet service is a multi part system which
i ChatterBox! Motorcycle Security
i Before you Start the Installation * Please read this manual to become familiar with the requirements necessary to complete the installation. * Use a high quality multi-meter to test all wires before
Charge Regulator SCR 12 Marine
Charge Regulator SCR 12 Marine Manual Many thanks for purchasing a superwind product. The SCR 12 Marine is a charge regulator of highest quality and will perfectly and reliably charge your batteries for
The self-starting solar-powered Stirling engine
The self-starting solar-powered Stirling engine This project began at the request of an artist who had proposed a Stirling-engine-powered sculpture to a client. The engine only had to run, not really produce
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
