- 9 years ago
- Views:
Transcription
1 FA-155 / May 1995
2 This document was scanned from hard copy to portable document format (PDF) and edited to 99.5% accuracy. Some formatting errors not detected during the optical character recognition process may appear.
3 EXPRESS RESIDENTIAL FIRE SPRINKLER DESIGN GUIDE U.S. Fire Administration Emmitsburg, MD A Cooperative Effort of Prince George s County, MD Fire Department Bureau of Engineering Services and NAHB Research Center, Inc. Upper Marlboro, MD January 1995
4 DISCLAIMER The information contained in this booklet is intended to be illustrative of the minimum requirements of the applicable standards. It is not a blueprint, nor a set of plans and specifications. Neither the Prince George s County Government, Prince George s County Fire Department, Research Center, the City of DuPont, the Federal Emergency Management Agency, nor persons in the employ of the previous entities, warrant or guarantee in any manner to any extent the sufficiency of the information contained in this booklet. The information contained in the booklet is not intended to be applicable to all conceivable field conditions. Prince George s County, MD, and the Research Center disclaim any and all liability for damages or injuries, direct or consequential, arising out of the use of the information contained in the booklet. Neither Prince George s County Government, the Prince George s County Fire Department, the Research Center, the City of DuPont or the Federal Emergency Management Agency or any member of their organization(s) nor any person acting on behalf of any of them: a. makes any warranty or representation whatsoever, express or implied, (I) with respect to the use of any information, apparatus, method, process, or similar item disclosed in this report, including merchantability and fitness for a particular purpose, or (II) that such use does not infringe on or interfere with privately owned rights, including any party s intellectual property, or (III) that this report is suitable to any particular user s circumstance; or b. assumes responsibility for any damages or other liability whatsoever (including any consequential damages, even if the Prince George s County Government, the Prince George s County Fire Department, the Research Center, the City of DuPont or the Federal Emergency Management Agency or any representative has been advised of the possibility of such damages) resulting from your selection or use of this report or any information, apparatus, method, process, or similar item disclosed in this report. ii
5 PROLOG The EXPRESS Residential Design Guide was prepared under a Cooperative Agreement with the Federal Emergency Management Administration (FEMA) and sponsored by the U.S. Fire Administration (USFA). As a cooperative effort between the NAHB Research Center, Inc., and the Bureau of Engineering Services, Prince George s County (Maryland) Fire Department, the Design Guide was developed for the installer as a method to simplify and expedite residential sprinkler design and layout. The Design Guide incorporates extensive experience concerning the installation of residential fire sprinklers in accordance with NFPA 13-D. The consensus of experience maintains that most homes can be pre-engineered following design methods contained in the NFPA 13-D standard. The Design Guide is intended only for use in residential applications to one and two family dwellings and townhouses and is intended to assist the user in preparing designs of residential sprinkler systems which are in compliance with the NFPA 13-D standard. In the case of any discrepancy found between the minimum design standards of NFPA 13-D and the Design Guide, the requirements of NFPA 13-D shall be considered as taking precedence. The writers seek qualified and responsible critique. Please address comments to: Program Manager Joint Residential Fire Projects NAHB Research Center, Inc. 400 Prince George s Boulevard Upper Marlboro, MD and David M. Banwarth, P.E. Chief Fire Protection Engineer Bureau of Engineering Services Prince George s County Fire Department County Administration Building Room 3100 Upper Marlboro, MD
6 THE EXPRESS RESIDENTIAL FIRE SPRINKLER DESIGN GUIDE The Guide provides a preliminary discussion of sprinkler coverage area, water flow, and water pressure. After this discussion, the Guide is divided into two parts: Part 1: Hydraulic Worksheet Calculations performed on this sheet enable the installer to account for pressure losses in the system, to ensure that adequate water flow and water pressure are available at the most remote sprinkler head. This information, in turn, is used to select pipe sizes for the system that will permit delivery of the required flow and pressure. Part 2: Sprinkler Target Zones The Guide eliminates the need to determine precise locations for sprinkler heads, and substitutes target zones within which sprinkler heads can be placed to provide adequate coverage. Part 2 provides instructions for using a templet to determine target zones for each room in the house. By following the methods described in the Guide, the installer can design a residential fire sprinkler system and determine the placement of the sprinkler heads. 2
7 QUESTIONS AND ANSWERS ABOUT THIS GUIDE What is the Purpose of the Guide? The purpose of the Guide is to provide a simplified method for designing and laying out home fire sprinkler systems. The simplification has been achieved by pre-engineering key features of the design. Use of the Guide can result in cost savings in sprinkler installation. Who Can Use The Guide? The Guide is intended for use by installers who are familiar with the installation of plastic and copper piping, and who possess a basic understanding of residential sprinkler system design and installation methods. How Does the Guide Relate to the Design Method of NFPA Standard 13-D? The method described in the Guide enables installers to design systems that conform to the requirements of National Fire Protection Association (NFPA) Standard 13-D, Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes (1994). Two important differences between the Guide s method and the current 13-D method are that the Guide estimates the fitting loss and does not require the installer to specify the exact layout of the piping in the system. Loops and Grids The Design Guide does not support the design of looped or gridded piping networks to supply sprinkler heads. Loops and grids may be utilized to improve the hydraulic performance of a system design, such benefits are not accounted for in this simplified design method. Installers should check with the local AHJ regarding the relationship of any fire sprinkler design method to local requirements. How Do Commercial and Residential Systems Differ? The conventional process for fire sprinkler system design and installation was developed in commercial, industrial, and institutional settings. Such settings generally require large, complex systems, which must be fully engineered and which require substantial design review by the local AHJ. The designs are typically based on a unique set of plans and hydraulic calculations that often require special certification. By comparison with commercial and industrial settings, homes are small. Home sprinkler systems are much less complex. The Guide is designed to make the advantages of this reduced complexity available to installers. 3
8 The Guide eliminates the need for detailed special plans because the system design is not tied to precise sprinkler head locations. Instead, sprinkler heads can be placed anywhere within target zones that are indicated on the house plans. The Guide substantially reduces and can eliminate the necessity for pre-installation design review. The hydraulics and head locations can be reviewed in the field after rough installation is complete. When requirements of actual construction make it necessary to change the layout of the piping or the location of sprinkler heads, conventional designs can require the submission of as-built plans. With the use of target zones, the need for as-built plans can be eliminated. What Materials and Tools Are Needed? All that is needed are scaled drawings of each floor of the house, and possibly a calculator. What Information Is Needed? Before beginning, the following information is required: Water Supply The available water pressure in the home. The length, size, and type of underground piping material used to supply water from the street main to the house. Change in Elevation The change in elevation between the water main and the highest sprinkler in the house. Sprinkler Specifications Water flow, pressure, and coverage specifications for the make and model of sprinkler head that will be used. These operating characteristics appear on the product information ( cut ) sheets furnished by the manufacturer. Specifications for any backflow prevention devices or special valves that may be used in the system. This information also accompanies the devices. What Kinds of Homes Are Covered by the Guide? The Guide can be used to design tree systems for most types of single-family homes. There are two exceptions: Placement of sprinkler heads on sloped ceilings. should be followed for this type of ceiling. Manufacturers installation guides Exceptionally large homes, or homes with unique layouts and design features. For such homes, installers should prepare a design plan in accordance with NFPA Standard 13-D. 4
9 COVERAGE AREA, WATER FLOW, AND WATER PRESSURE Sprinkler heads require different flow rates and water pressures to cover different room areas. A typical manufacturer s specification is shown in Table 1. Table 1 Sample Sprinkler Specification Sprinkler heads should be chosen that require as little flow as possible for the greatest coverage area. Flow rates as low as 9 to 12 gallons per minute (gpm) for a coverage area of 14 x 14 are available and constitute a desirable range. Coverage Area In the method described in the Guide, the term Coverage Area designates a single sprinkler rating representing the greatest coverage that any individual sprinkler head on the system will have to achieve. This Coverage Area dictates the flow rate and the pressure for the system. Selection of this rating is therefore the first step. Manufacturers coverage-area specifications for sprinkler heads typically run from 12 x 12 or less, to 20 x 20, as shown in Table 1. Room Width The Guide uses the width of the room as the principal dimension for determining the Coverage Area. The width is defined as the measurement of the shorter side of the room. Here is the basic rule: The greatest room width that does not exceed the greatest coverage area rating of the sprinkler heads, will determine the Coverage Area for the system being designed. In the following example, the house contains four rectangular rooms: 5
10 Room #l : width, 12 feet, length 14 feet Room #2: width, 15 feet, length 19 feet Room #3: width, 18 feet, length 18 feet Room #4: width, 26 feet, length 30 feet Let us assume that the maximum Coverage Area for the sprinkler heads being used in the system is 20 x 20. The width of Room #3, 18 feet, comes closest to the maximum rating of the heads without exceeding it. We therefore select a Coverage Area of 18 x 18 for the system. Now let s take the rooms one by one. Room #l. Since the Coverage Area that we have chosen is greater than either dimension of this room, only one sprinkler head is required. Room #2 has a width of 15 feet and a length of 19 feet. Since the length exceeds the maximum reach of our 18-foot-by-18-foot Coverage Area, a second head will be needed to provide full coverage in this room. Room #3 s 18-foot length and width both fit our Coverage Area. One sprinkler head will be sufficient. Room #4 s width and length both exceed the maximum reach of the sprinkler head. A second row of sprinklers will be required for this room. Each row will contain two sprinklers. Room Width and Coverage Area Table 2 summarizes the relationship between Room Width and Coverage Area. Where room widths exceed the maximum for the sprinkler head being used, the Coverage Area should be selected in accordance with the table, with the understanding that two rows of sprinkler heads are required. Table 2 Room Width and Coverage Area 6
11 For example, consider a house with an 17-foot x 24-foot living room and a 32-foot x 40-foot basement. For the 17-foot-wide living room, the Coverage Area selected is 18 x 18 feet. The room requires a single row of two sprinklers to cover its 24-foot length. Figure 1 shows the target zones within which the sprinklers can be placed. Figure 1 Living Room with Target Zones For the basement, we find 32 feet under Room Width in Table 2. The table shows that the Coverage Area will be 16 feet, which falls within the 18-foot Coverage Area that we have already selected. However, two rows of sprinklers will be required to achieve 32-foot coverage. Each row will contain three sprinklers, to reach the full length of 40 feet. Figure 2 shows the target zones within which the sprinklers can be placed. Figure 2 Basement with Target Zones 7
12 Design Water Flow (DWF) and Pressure Two system operating characteristics, the Design Water Flow (DWF) and the Water Pressure, are based on the selected Coverage Area of the sprinkler. Single Sprinkler Head In the event that each room in the house has only one sprinkler head, then both the DWF and the required Water Pressure can be taken directly from the manufacturer s specifications for Single-Head Flow for the chosen Coverage Area for use on the hydraulic calculation worksheet. As an example, suppose that all rooms have one sprinkler head each, and the Coverage Area is 18 x 18. Suppose, too, that the manufacturer s specifications exactly duplicate those in Table 1. The table gives the DWF of an 18 x 18 Coverage Area as 14 gallons per minute (gpm) and the pressure as 12.9 pounds per square inch (psi). Multiple Sprinkler Heads If there are more than one sprinkler head in any room of the house, then the Multiple-Head Flow and the Single-Head Pressure from the manufacturer specification, and are used on the Hydraulic Calculation Work Sheet. The Multiple-Head Flow Rate is used because it is possible that two heads in a given room with two or more sprinklers may be activated simultaneously. The Single-Head Pressure is used because this makes it possible to perform one calculation to determine adequate pressure and flow for all heads on the system, regardless of the number of heads in any individual room. As an example, suppose that we have selected a Coverage Area of 18 x 18, and that one room in the house has two sprinkler heads. If the manufacturer s specifications are the same as those in Table 1, then the DWF is 24 gpm (12 x 2), and the Pressure is 12.9 psi. Maximum Flow Rate The maximum flow rate for which the Guide can be used is 32 gpm. Greater flows will benefit from more detailed design procedures than those described in the Guide. 8
13 PART 1: THE HYDRAULIC WORKSHEET The Hydraulic Worksheet is used to determine the available pressure for the piping in the sprinkler system. This available pressure provides the basis for selecting types and sizes of piping that will permit the required pressure and water flow to be delivered to the farthest sprinkler head. There is a drop in pressure between the tap of the public main and the farthest sprinkler head. This drop stems from four sources:. devices in the system that impede the water flow;. pressure loss as the water flows through the piping from the public main to the beginning of the sprinkler system;. rise in elevation between the tap of the public main and the highest sprinkler head in the house; and. pressure loss as water travels from the system entry point to the farthest head. The Hydraulic Work Sheet is used to determine the available water pressure and flow rate at the farthest head after accounting for all losses. Appendix B is then used to choose types and sizes of pipe that will deliver the required pressure and flow rate. The steps for calculating pressure losses on the Hydraulic Work Sheet are as follows: 1. Room Width and Coverage Area Enter in 1A the largest Room Width that does not exceed the greatest coverage area rating of the sprinkler heads. Enter the selected Coverage Area in 1B. 2. Sprinkler Head Specifications For the Coverage Area in lb, fill in the following information from the manufacturer s specification sheet that is provided with the sprinkler heads: 2A: Single-Head Flow Rate; 2B: Single-Head Pressure; and 2C: Dual-Head Flow Rate. 3. Design Water Flow (DWF) and Design Pressure If all rooms in the house will have only one sprinkler head, enter the Single-Head Flow Rate (2A) in 3A. 9
14 If there will be more than one sprinkler head in any room of the house, enter the Dual-Head Blow Rate (2C) in 3B, and multiply by 2. The applicable entry 3A or 3B x 2 is the system s Design Water Flow (DWF). Enter it on Line 1. The Single-Head Pressure from 2B is used for the Design Sprinkler Pressure. Enter it on Line Water Pressure at the Public Main This is the pressure in the public main of the local water supply system. The figure can be obtained from the utility. Enter it on Line Pressure Losses Caused by Devices These losses are totalled as follows: A. Backflow Prevention Device; Check Valve If a backflow prevention device is present, secure the pressure loss at the DWF, from the manufacturer s specifications. Enter it on Line 4. If the system employs a check valve rather than a backflow prevention device, Table 3 can be used to determine the pressure loss. Enter it on Line 4. Table 3 Pressure Loss in Devices If the system has neither type of device and employs a direct connection to provide flow in the system enter 0 on Line 4. B. Water Meter Determine the size of the system s water meter, and enter it in 5B. 10
15 Using Table 3, find the pressure loss for this size meter at the system s Design Water Blow (Line 1). Enter this figure on Line 5. C. Valves Enter the number of gate or ball valves in 5C. Multiply by the figure that appears under the system s Design Water Flow in Table 3. Enter this figure on Line Pressure Losses in Underground Supply Piping In 6A and 6B, enter the sizes and types of underground water service piping that extends from the public main to the house. Appendix A provides Pressure Loss Tables for various Design Water Flows, for different types of pipe of various sizes and lengths. Choose the table which matches the underground pipe. Go down the pipe lengths in the left-hand column and choose the first one that is equal to or greater than the length of pipe that is being checked. Run across the column to the system s Design Water Flow to find the pressure loss. Enter this number on Line 7A. Repeat the process for an additional pipe section, and enter the number on Line 7B. 7. Elevation Pressure Loss An additional factor affecting pressure is the difference in elevation between the tap point at the water main and the highest sprinkler head in the system. Enter the difference in elevation at 7, and divide by 2. Enter the result on Line Sum of Losses and Pressure at the Farthest Head Add Lines 2, 4, 5, 6, 7A, 7B, and 8. Enter on Line Available Pressure for Piping To determine the available pressure for piping, subtract Line 9 from Line 3 and enter the result on Line Selection of Pipe Type and Size Complete section 10 by using the tables in Appendix B to make pipe selection(s). 11
16 Choose the appropriate table for the DWF that you have entered on Line 1. Choose the pressure loss in the vertical left-hand column that is equal to or less than the Available Pressure for Piping on Line 10. Running across the table, choose a single pipe type or a combination of pipe types that will extend to the farthest sprinkler head. For example, Figure 3 shows a portion of the 18 gpm Table in Appendix B. If the Available Pressure for Piping on Line 10 is 22 psi, the table shows the available piping options. These options indicate the maximum pipe run that can be accommodated by each type of pipe. All lines except the first assume the use of two different types of piping in the maximum-length run. Select one length from Section A and one from Section B. Their combined length must accommodate the length of the run to the farthest sprinkler head. The highlighted row in Figure 3 shows the maximum allowable length for a combined run of one-inch copper Type M and one-inch CPVC pipe. The copper portion of the run can be as long as. 50 feet, and the CPVC part of the run can be as long as 101 feet. 12 Figure 3 Allowable Inside Pipe Lengths at 18 GPM Design Water Flow (DWF),
17 HYDRAULIC WORKSHEET 1. ROOM WIDTH AND COVERAGE AREA A. Room Width: ft. B. Coverage Area: ft. x ft. 2. SPRINKLER HEAD SPECIFICATIONS A. Single-Head Flow Rate: B. Single-Head pressure: psi. C. Dual-Head Flow Rate: gpm. 3. DESIGN WATER FLOW (DWF) AND DESIGN PRESSURE A. If all rooms have only one sprinkler head: DWF (from 2A): gpm. B. If more than one head in any room: DWF (From 2C): x2= gpm. Design Water Flow (A or B above): Design Sprinkler pressure (From 2B): Line 1: Line 2: gpm psi 4. WATER PRESSURE AT THE PUBLIC MAIN Line 3: psi 5. PRESSURE LOSSES CAUSED BY DEVICES A. Backflow prevention Device; Check Valve B. Water Meter Loss Water Meter Size: Line 4: psi pressure Loss (Use DWF on Line 1, and Table 3) Line 5: psi C. Gate or Ball Valve Loss (Use DWF and Table 3) X psi = No. Valves Loss Line 6: psi 13
18 6. PRESSURE LOSSES IN UNDERGROUND SUPPLY PIPING Find the Pressure Losses based on the DWF on Line 1 and Tables in Appendix A. A. Underground Section #l Piping,, ft: Pressure Loss = Size Type Length B. Underground Section #2 Piping,, ft: Pressure Loss = Size Type Length Line 7A: Line 7B: psi psi 7. ELEVATION PRESSURE LOSS Difference in elevation between water main tap point and highest sprinkler (if the sprinkler head is lower, the number is negative): /2= Line 8: psi 8. SUM OF LOSSES AND SPRINKLER PRESSURE Line 2 Line 4 Line 5 Line = Line 7A Line 7B Line 8 Line 9: psi 9. AVAILABLE PRESSURE FOR PIPING - = Line 3 Line 9 Line 10: psi 10. SELECTION OF PIPE TYPE AND SIZE Use the appropriate Table in Appendix B, based on the DWF, Line 1. Find the Available Pressure for Piping, Line 9, in the Table s left-hand column. Select the piping type(s) and size(s). INSIDE SECTION A:,, Type Size ft. maximum straight length INSIDE SECTION B:,, ft. maximum straight length Type Size 14
19 PART 2: SPRINKLER TARGET ZONES In the traditional sprinkler head placement method, the exact locations of the sprinkler heads are indicated on a set of sprinkler plans and must be fixed according to the hydraulic design. A typical placement is shown in Figure 4. However, considerations that arise during construction often prevent installation at design location shown on the drawings. Deviations from the locations indicated on the plans can cause coordination problems with trades, and can result in re-inspection and the submittal of as-built plans. Instead of exact locations, the Guide substitutes target zones within which the sprinkler heads can be placed. Placement of the sprinkler heads anywhere within the target zones meets the requirement of NFPA 13-D to comply with the manufacturers coverage area specifications. This method simplifies planning and design. A typical target zone created by use of the Guide is shown in Figure 5. The Target Zone Templet In Appendix C, two templets are provided, one for plans drawn to 1/4" = 1 scale, and one for plans drawn to 1/8" = 1 scale. Figure 6 shows a reduced copy of the 1/4" templet. The templets have four features: Along the left-hand edge: A scale rule marked in feet, for taking measurements on the drawing. On the lower portion: Squares representing sprinkler coverage areas ranging from 12 x 12 to 20 x 20. In the middle: An eight-foot scale, used to establish eight-foot minimum spacing between sprinklers as required by NFPA 13-D. In the upper right-hand corner: The scales that are used to lay out the target zones on the plans. Limitations of Template Use There are two limitations on use of the templet: Do not use the templet to determine target zone locations on other than flat ceilings. In areas that are subject to heat from such sources as stove tops, fireplaces, furnaces, and hot water heaters, the target zone may have to be modified in accordance with the manufacturers installation guides for procedures relating to such areas. 15
20 Figure 4 Traditional Placement of Sprinkler Heads Figure 5 Typical Target Zone Based on 16 x 16 Coverage 16
21 RESIDENTIAL SPRINKLER TARGET ZONE TEMPLET 1/4" = 1 scale MINIMUM BETWEEN DISTANCE SPRINKLERS Figure 6 Template for the Creation of Target Zones (not to seale) 17
22 Two Initial Steps Two steps must be taken before measurements begin: The applicable templet-- 1/4 or 1/8 --must be copied onto a transparency of the type used for overhead projections. With this transparency, house plans can be seen beneath the templet. The two sides of the target zone scale that face the edges of the sheet, must be trimmed along the lines marked edge line. This is shown in Figure 7. Coverage Area Use of the templet to lay out target zones is based on the Coverage Area that has been selected for the system. This figure appears on the Hydraulic Work Sheet, Item 1B. Creating a Target Zone Creating a target zone by means of the templet is shown in Figures 8 and 9. In this example, the Coverage Area selected for the system is 16 x 16, and the room in which the sprinkler head is to be installed is 13 x
23 Figure 7 Trim Target Zone at Edge Line 19
24 20 Figure 8 Creating One Corner of the Target Zone
25 Figure 9 Creating the Second Corner of the Target Zone 21
26 The steps are as follows: To match the dimensions of the Coverage Area, the 16 x 16 scale in the upper right corner of the templet is employed. Place this scale on one corner of the room on the plans, with the dot in the corner, as shown in Figure 8. Trace the comer of the scale edges onto the drawing. Place the scale on the diagonally opposite sides of the room with the dot in the comer, as shown in Figure 9. Trace the comer of the scale edges onto the drawing. The two right-angle markings will overlap in an area in the middle of the room. This is the Target Zone. Three Types of Rooms Rooms will fall into three general types. Procedures, illustrated in Figure 10, for each type are as follows: Type 1 - Rooms whose length and width are both less than the width of the Coverage Area. This type of room will require only one sprinkler head. Use of the template to locate the target zone is described above. Type 2 - Rooms whose width is less than the width of the Coverage Area, but whose length exceeds the length of the Coverage Area. This type of room will require two sprinkler heads. The steps are as follows: 1. Divide the room in half along its length on the plans. 2. Treat each half as a separate room, and proceed as described above. Type 3 - Rooms whose length and width both exceed the length and width of the Coverage Area. This type of room will require two rows of sprinkler heads, with each row having two heads. The steps are as follows: 1. Divide the room in half along both its length and width. 2. Treat each of the four sections as a separate room, and proceed as above. 22
27 Using 16 x 16 Spacing: Type 1: Room Width and Length Less Than Coverage Area Type 2: Room Width Less Than Coverage Area, Room Length Greater, Than Coverage Area Type 3: Room Width and Length Greater Than Coverage Area Figure 10 Target Zones in Different Room Types 23
28 Sidewall Sprinklers To determine target zones for sidewall sprinklers, proceed as follows: Select the wall on which the sprinkler head will be placed. Place the templet on one side of a scale plan of the wall and trace one edge of the template onto the drawing as shown in Figure 11. Move the templet to the opposite edge, and trace the edge onto the drawing. This will create a pair of parallel lines on the drawing. The space between them is the target zone. For walls with more than one sprinkler, divide the wall in half and treat each half as an independent wall section.
29 Figure 11 Target Zone for Sidewall Sprinklers 25
30 APPENDIX A PRESSURE LOSS TABLES UNDERGROUND PIPING
31 PRESSURE LOSS TABLE (psi) Page A-1 3/4" COPPER PIPE (any type)
32 PRESSURE LOSS TABLE (psi) Page A-2 1" COPPER PIPE (any type)
33 PRESSURE LOSS TABLE (psi) Page A-3 1 1/4" COPPER PIPE (any type)
34 PRESSURE LOSS TABLE (psi) Page A-4 1 1/2" COPPER PIPE (any type)
35 PRESSURE LOSS TABLE (psi) Page A-5 2" COPPER PIPE (any type)
36 PRESSURE LOSS TABLE (psi) Page A-6 1" POLYBUTELENE (PB) TUBING - SDR 9
37 PRESSURE LOSS TABLE (psi) Page A-7 1 1/4" POLYBUTELENE (PB) TUBING - SDR 9
38 PRESSURE LOSS TABLE (psi) Page A-8 1 1/2" POLYBUTELENE (PB) TUBING - SDR 9
39 PRESSURE LOSS TABLE (psi) Page A-9 2" POLYBUTELENE (PB) TUBING - SDR 9
40 PRESSURE LOSS TABLE (psi) Page A-10 1" POLYETHYLENE (PE) PIPE - SIDR-PR
41 PRESSURE LOSS TABLE (psi) Page A /4" POLYETHYLENE (PE) PIPE - SIDR-PR
42 PRESSURE LOSS TABLE (psi) Page A /2" POLYETHYLENE (PE) PIPE - SIDR-PR
43 PRESSURE LOSS TABLE (psi) Page A-13 2" POLYETHYLENE (PE) PIPE - SIDR-PR
44 PRESSURE LOSS TABLE (psi) Page A-14 3/4" CPVC PIPE - SDR-13.5
45 PRESSURE LOSS TABLE (psi) Page A-15 1" CPVC PIPE - SDR-13.5
46 PRESSURE LOSS TABLE (psi) Page A /4" CPVC PIPE - SDR-13.5
47 PRESSURE LOSS TABLE (psi) Page A /2" CPVC PIPE - SDR-13.5
48 PRESSURE LOSS TABLE (psi) Page A-18 2" CPVC PIPE - SDR-13.5
49 PRESSURE LOSS TABLE (psi) Page A-19 1" PVC PIPE - SDR-21
50 PRESSURE LOSS TABLE (psi) Page A /4" PVC PIPE - SDR-21
51 PRESSURE LOSS TABLE (psi) Page A /2" PVC PIPE - SDR-21
52 PRESSURE LOSS TABLE (psi) Page A-22 2" PVC PIPE - SDR-21
53 APPENDIX B TABLES FOR MAXIMUM SPRINKLER STRAIGHT PIPE RUNS
54 Page B-1 ALLOWABLE INSIDE PIPE LENGTHS AT 10 GPM DESIGN WATER FLOW (DWF) CHOOSE 1 ROW USING - ONE COLUMN FROM PIPE SECTION A PLUS ONE COLUMN FROM PIPE SECTION B Table numbers represent 44% of the total pipe length available at the given pressure (fittings 56% of total pipe length). To find the total pipe length available at the given pressure, multiply the column value times 2.25.
55 Page B-2 ALLOWABLE INSIDE PIPE LENGTHS AT 12 GPM DESIGN WATER FLOW (DWF) CHOOSE 1 ROW USING - ONE COLUMN FROM PIPE SECTION A PLUS ONE COLUMN FROM PIPE SECTION B Table numbers represent 44% of the total pipe length available at the given pressure (fittings 56% of total pipe length). To find he total pipe length available at the given pressure, multiply the column value times 225.
56 Page B-3 ALLOWABLE INSIDE PIPE LENGTHS AT 14 GPM DESIGN WATER FLOW (DWF) CHOOSE 1 ROW USING - ONE COLUMN FROM PIPE SECTION A PLUS ONE COLUMN FROM PIPE SECTlON B Table numbers represent 44% of the total pipe length available at the given pressure (fittings 56% of total pipe length). To find the total pipe length available at the given pressure, multiply the column value times 2.25.
57 Page B-4 ALLOWABLE INSIDE PIPE LENGTHS AT 16 GPM DESIGN WATER FLOW (DWF) CHOOSE 1 ROW USING. ONE COLUMN FROM PIPE SECTlON A PLUS ONE COLUMN FROM PIPE SECTION B Table numbers represent 44% of the total pipe length available at the given pressure (fittings 56% of total pipe length). To find the total pipe length available at the pressure, multiply the column value times 2.25.
58 Page B-5 ALLOWABLE INSIDE PIPE LENGTHS AT 18 GPM DESIGN WATER FLOW (DWF) CHOOSE 1 ROW USING - ONE COLUMN FROM PIPE SECTION A PLUS ONE COLUMN FROM PIPE SECTION B Table numbers represent 44% of the total pipe length avaulable at the given pressure (fittings 56% of total pipe length) To find the total pipe length available at the given pressure, multiply the column value times 2.25.
59 Page B-6 ALLOWABLE INSIDE PIPE LENGTHS AT 20 GPM DESIGN WATER FLOW (DWF) CHOOSE 1 ROW USING - ONE COLUMN FROM PIPE SECTION A PLUS ONE COLUMN FROM PIPE SECTION B Table numbers represent 44% of the total pipe length available at the given pressure (fittings 55% of total pipe length). To find the total pipe length available at the given pressure, multiply the column value times 225.
60 Page B-7 ALLOWABLE INSIDE PIPE LENGTHS AT 22 GPM DESIGN WATER FLOW (DWF) CHOOSE 1 ROW USING - ONE COLUMN FROM PIPE SECTION A PLUS ONE COLUMN FROM PIPE SECTION B Table numbers represent 44% of the total pipe length available at the given pressure (fittings 56% of total pipe length). To find the total pipe length available at the given pressure, multiply the column value times 2.25.
61 Page B-8 ALLOWABLE INSIDE PIPE LENGTHS AT 24 GPM DESIGN WATER FLOW (DWF) CHOOSE 1 ROW USING - ONE COLUMN FROM PIPE SECTION A PLUS ONE COLUMN FROM PIPE SECTION B Table numbers represent 44% of the total pipe length available at the given pressure (fittings 56% of total pipe length) To find the total pipe length available at given pressure, multiply the column times 2.25.
62 Page B-9 ALLOWABLE INSIDE PIPE LENGTHS AT 26 GPM DESIGN WATER FLOW (DWF) CHOOSE 1 ROW USING-ONE COLUMN FROM PIPE SECTION A PLUS ONE COLUMN FROM PIPE SECTION B Table numbers represent 44% of the total pipe length available at the given pressure (fittings 56% of total length). To find the total pipe length available at the given pressure, multiply the column value times 225.
63 Page B-10 ALLOWABLE INSIDE PIPE LENGTHS AT 28 GPM DESIGN WATER FLOW (DWF) CHOOSE 1 ROW USING - ONE COLUMN FROM PIPE SECTION A PLUS ONE COLUMN FROM PIPE SECTION B Table numbers represent 44% of the total pipe length available at the given pressure (fittings 56% of total pipe length) To find the total pipe length available at the given pressure, multiply the column value times 2.25.
64 Page B-11 ALLOWABLE INSIDE PIPE LENGTHS AT 30 GPM DESIGN WATER FLOW (DWF) CHOOSE 1 ROW USlNG - ONE COLUMN FROM PIPE SECTION A PLUS ONE COLUMN FROM PIPE SECTION B Table numbers represent 44% of the total pipe length available at the given pressure (fittings 56% of total pipe length). To find the total available pipe length at the given pressure, multiply the column values times 2.25.
65 Page B-12 ALLOWABLE INSIDE PIPE LENGTHS AT 32 GPM DESIGN WATER FLOW (DWF) CHOOSE 1 ROW USING - ONE COLUMN FROM PlPE SECTION A PLUS ONE COLUMN FROM PlPE SECTION B Table numbers represent 44% of the total pipe length available at the given pressure (fittings 56% of total pipe length). To find the total available pipe length at the given pressure, multiply the column value times 2.25.
66 APPENDIX C SPRINKLER LAYOUT TEMPLETS DESIGN GUIDE WORKSHEET
67 RESIDENTIAL SPRINKLER TARGET ZONE TEMPLET 1/4" = 1 scale MINIMUM DISTANCE BETWEEN SPRINKLERS
68 RESIDENTIAL SPRINKLER TARGET ZONE TEMPLET 1/8" = 1 scale MINIMUM DISTANCE BETWEEN SPRINKLERS
69 Page 1 of 2 HYDRAULIC WORKSHEET 1. ROOM WIDTH AND COVERAGE AREA A. Room Width: ft. B. Coverage Area: ft. x ft. 2. SPRINKLER HEAD SPECIFICATIONS A. Single-Head Flow Rate: gpm. B. Single-Head Pressure: psi. C. Dual-Head Flow Rate: gpm. 3. DESIGN WATER FLOW (DWF) AND DESIGN PRESSURE A. If all rooms have only one sprinkler head: DWF (from 2A): gpm. B. If more than one head in any room: DWF (From 2C): x2= gpm. Design Water Flow (A or B above): Design Sprinkler Pressure (From 2B): Line 1: Line 2: gpm psi 4. WATER PRESSURE AT THE PUBLIC MAIN Line 3: psi 5. PRESSURE LOSSES CAUSED BY DEVICES A. Backflow Prevention Device; Check Valve Line 4: -----Psi B. Water Meter Loss Water Meter Size: Pressure Loss (Use DWF on Line 1, and Table 3) Line 5: psi C. Gate or Ball Valve Loss (Use DWF and Table 3) X psi = No. Valves Loss Line 6: psi
70 Page 2 of 2 6. PRESSURE LOSSES IN UNDERGROUND SUPPLY PIPING Find the Pressure Losses based on the DWF on Line 1 and Tables in Appendix A. A. Underground Section #1 Piping,, ft: Pressure Loss = Size Type Length B. Underground Section #2 Piping,, ft: Pressure Loss = Sire Type Length Line 7A: Llne 7B: psi psi 7. ELEVATION PRESSURE LOSS Difference in elevation between water main tap point and highest sprinkler (if the sprinkler head is lower, the number is negative): /2 = Line 8: psi 8. SUM OF LOSSES AND SPRINKLER PRESSURE Line 2 Line 4 Line 5 Line = Line 7A + Line 7B + Line 8 Line 9: psi 9. AVAILABLE PRESSURE FOR PIPING - Line 3 Line 9 = Line 10: psi 10. SELECTION OF PIPE TYPE AND SIZE Use the appropriate Table in Appendix B, based on the DWF, Line 1. Find the Available Pressure for Piping, Line 9, in the Table s left-hand column. Select the piping type(s) and size(s). INSIDE SECTION A:,, ft. maximum straight length Type Size INSIDE SECTION B:,, ft. maximum straight length Type Size
71 APPENDIX D INSIDE DIAMETER TABLE FITTING LOSS TABLE FRICTION LOSS TABLE
72 INSIDE DIAMETER TABLE FOR PIPE AND TUBE (INCHES) Hazen-Williams formula (psi/ft): where f.l. = friction loss Q = flow rate C = roughness factor d = inside pipe diameter 4.52 * Q1.85 f.1. = C 1.85 * d 4.87
73 FRICTION LOSS IN FITTINGS (equivalent feet of pipe)
74 FRlCTlON LOSS FACTOR TABLE (psi/ft)
Surge Pressure in Plumbing Pipe Materials
Surge Pressure in Plumbing Pipe Materials Prepared for Plastics Pipe Institute, Inc. 15 Decker Court, Suite 825 Irving, Texas 7562 Prepared by NAHB Research Center 4 Prince George s Blvd. Upper Marlboro,
SIZING OF WATER PIPING SYSTEM
SIZING OF WATER PIPING SYSTEM SECTION E101 GENERAL E101.1 Scope. E101.1.1 This appendix outlines two procedures for sizing a water piping system (see Sections E103.3 and E201.1). The design procedures
Clark County Fire Prevention
Clark County Fire Prevention Mission Statement: To provide the highest level of fire protection and related services TITLE: REQUIREMENTS FOR A NEW SPRINKLER SYSTEM IN ACCORDANCE WITH THE 2002 EDITION OF
SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved;
Pacific Pump and Power
Pacific Pump and Power 91-503 Nukuawa Street Kapolei, Hawaii 96707 Phone: (808) 672-8198 or (800) 975-5112 Fax: (866) 424-0953 Email: [email protected] Web: www.pacificpumpandpower.com Pumps
SIZING AND CAPACITIES OF GAS PIPING
APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING (This appendix is informative and is not part of the code.) A.1 General. To determine the size of piping used in a gas piping system, the following
C I T Y O F S E L M A F I R E D E P A R T M E N T
C I T Y O F S E L M A F I R E D E P A R T M E N T Informational Bulletin Regarding Residential Fire Sprinkler Systems for One and Two Family Homes: Frequently Asked Questions ADMINISTRATIVE PROVISIONS:
Roland Garcia Pearland Fire Department
Roland Garcia Pearland Fire Department NFPA13D Texas Legislation Conflicting Views - Fire Service and Home Builders Incentives offered in the ICC Detect and control residential fires Prevent injury and
SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon)
(IFGS) SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon) (This appendix is informative and is not part of the code. This appendix is an excerpt from the 2006 International Fuel Gas
APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM
APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM Because of the variable conditions encountered, it is impractical to lay down definite detailed rules of procedure for determining the sizes
PLUMBING CODE REQUIREMENTS AND SIZING GUIDE FOR RESIDENTIAL WATER SOFTENERS. Second Edition. Prepared by
PLUMBING CODE REQUIREMENTS AND SIZING GUIDE FOR RESIDENTIAL WATER SOFTENERS Second Edition Prepared by NAHB Research Center, Inc. 400 Prince Georges Boulevard Upper Marlboro, MD 20774-8731 DISCLAIMER This
Automatic Fire Sprinkler Submittal Requirements
Automatic Fire Sprinkler Submittal Requirements All commercial and industrial buildings with a total floor area of 5000 sq. ft. shall have an approved automatic sprinkler system installed. The Windsor-Severance
SIZING AND CAPACITIES OF GAS PIPING
CALIFORNIA RESIDENTIAL CODE MATRIX ADOPTION TABLE APPENDIX A SIZING AND CAPACITIES OF GAS PIPING (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state
SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13R
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13R Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved;
One of the fundamental design elements that every
Preliminary Design Information Before starting the water system design, you must assemble a collection of information. This includes information from the owner, the local utility, and the architect. Things
RESIDENTIAL SPRINKLER INSTALLATION GUIDE
RESIDENTIAL SPRINKLER INSTALLATION GUIDE 4077 AIR PARK DRIVE STANDISH, MICHIGAN 48658 PHONE 989-846-4583 800-248-0278 FAX 989-846-9231 www.globesprinkler.com A-15 GLOBE RESIDENTIAL SPRINKLER GUIDE DESCR.,
WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS
GAP.14.1.2.2 A Publication of Global Asset Protection Services LLC WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS INTRODUCTION A hydrant or other large-volume flow test is necessary for proper water
Guide for Efficient Hot Water Delivery Systems
s 1.0 Introduction This guide is designed to help builders better understand and meet the hot water delivery system criteria as specified in the WaterSense New Home Specification (WaterSense new home specification).
Residential Plan Review Emergency Vehicle Access and Water Supply Permit Information Packet
Residential Plan Review Emergency Vehicle Access and Water Supply Permit Information Packet 1. Definitions a. AHJ Authority Having Jurisdiction. The Fire Chief or Fire Marshal of a given Fire District
CHAPTER 2 HYDRAULICS OF SEWERS
CHAPTER 2 HYDRAULICS OF SEWERS SANITARY SEWERS The hydraulic design procedure for sewers requires: 1. Determination of Sewer System Type 2. Determination of Design Flow 3. Selection of Pipe Size 4. Determination
SPRINKLER SYSTEM PLANS AND CALCULATIONS CHECK LIST
SPRINKLER SYSTEM PLANS AND CALCULATIONS CHECK LIST 1. Working plans shall be drawn to an indicated scale, on sheets of uniform size, with a plan of each floor, and shall show those items from the following
CHAPTER 11 STORM DRAINAGE
CHAPTER 11 STORM DRAINAGE SECTION 11 GENERAL 11.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. 11.2 Where required. All roofs,
OCFRD TENT STANDARD 6000. This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.
1. Authority Orange County Fire Rescue Department Tents & Membrane Structures Office of The Fire Marshall - 109 E. Church Street, Lower Level - Orlando, Florida 32801-3319 Phone: 407-836-0004 Fax: 407-836-8310
Chapter 7 Plumbing Connections
Chapter 7 Plumbing Connections 7-1 General All plumbing equipment and installations must be designed, constructed, and installed in accordance with this code and where not specific, to the applicable provisions
MD5-26 Stacking Blocks Pages 115 116
MD5-26 Stacking Blocks Pages 115 116 STANDARDS 5.MD.C.4 Goals Students will find the number of cubes in a rectangular stack and develop the formula length width height for the number of cubes in a stack.
Builder Specifications for Solar Ready Homes
Builder Specifications for Solar Ready Homes This document specifies the essential elements required to make a new home ready for the future installation of roof-mounted solar domestic hot water and photovoltaic
NFPA 13 2002 FAQs. 3. Can plastic pipe be used on a sprinkler system complying with NFPA 13?
NFPA 13 2002 FAQs Responses to FAQs are prepared by NFPA technical staff to assist users in reading and understanding NFPA codes and standards. The responses, however, are not Formal Interpretations issued
Installation & Technical Guide
Of the very few negative responses that I have received regarding this product, the one that I find most humorous is this one: Contractors are too rough on the product. I don t think this can stand up
Solving Geometric Applications
1.8 Solving Geometric Applications 1.8 OBJECTIVES 1. Find a perimeter 2. Solve applications that involve perimeter 3. Find the area of a rectangular figure 4. Apply area formulas 5. Apply volume formulas
Introduction to Water Pipe Sizing
ONTARIO PLUMBING INSPECTORS ASSOCIATION INC. In the public service since 1920 Introduction to Understanding the Many Methods to Size Water Pipe Presented by: Rainier Bratsch-Blundel, CPSI Plumbing Professor
Cost Estimation for Materials and Installation of Hot Water Piping Insulation
Cost Estimation for Materials and Installation of Hot Water Piping Insulation Prepared for Pacific Northwest National Laboratory Under Contract Number: 18O9O2 By Gary Klein, Managing Partner Affiliated
SECTION 5: SANITARY SEWER SYSTEM DESIGN
SECTION 5: SANITARY SEWER SYSTEM DESIGN 5.01 GENERAL Sanitary sewer improvements shall be designed to serve the ultimate level of City development as defined in the General Plan and the Wastewater Facilities
AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS
AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS Products Include: 60 gpm eductors Style 3060, 3061, 3062 & 3070 95 gpm eductors Style
Site Development Information Worksheet for single family residential development
Site Development Information Worksheet for single family residential development Project description: Address: Owner Name: Phone No. Date Signature & phone number of Individual who Completed this Worksheet
Design Criteria & Service Goals
4.1 Design Life of Improvements The design life of a water system component is sometimes referred to as its useful life or service life. The selection of a design life is a matter of judgment based on
MERCER ISLAND FIRE DEPARTMENT FIRE COMMERCIAL SPRINKLER STANDARDS
MERCER ISLAND FIRE DEPARTMENT FIRE COMMERCIAL SPRINKLER STANDARDS COMMERCIAL FIRE SPRINKLER SYSTEMS Page 1-5 SCOPE: Fire sprinkler systems in the City of Mercer Island shall meet the criteria as set forth
R-Value and Thermal Conductivity of PEX and PE-RT TR-48/2014
R-Value and of PEX and PE-RT TR-48/2014 Foreword R-VALUE AND THERMAL CONDUCTIVITY OF PEX AND PE-RT TR-48/2014 This technical report was developed and published with the technical help and financial support
2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS
2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS Water system improvements proposed for inclusion into Western s service area shall be designed in accordance with all appropriate AWWA standards, include
SECTION 1 GENERAL REQUIREMENTS
Page 1 of 6 SECTION 1 GENERAL REQUIREMENTS 1. SCOPE OF WORK: The work to be performed under the provisions of these documents and the contract based thereon includes furnishing all labor, equipment, materials,
Viking Residential Sprinkler Installation Guide
Viking Residential Sprinkler Installation Guide January, 2009 Trusted Above AllT M www.flowbusiness.cl Sprinkler RES1 January 9, 2009 1. DESCRIPTION Viking residential automatic sprinklers are equipped
VILLAGE OF RADIUM HOT SPRINGS Telephone 250-347-6455 Box 340 Facsimile 250-347-9068
VILLAGE OF RADIUM HOT SPRINGS Telephone 250-347-6455 Box 340 Facsimile 250-347-9068 Radium Hot Springs, BC www.radiumhotsprings.ca V0A 1M0 Dear Applicant, RE: Building Permit Applications Pursuant to the
Gas Line Sizing. Z Maximum gas demand shall be determined by adding all of the equipment Btu ratings from appliances connected on the system.
Gas Line Sizing When sizing Gas piping systems certain factors must be considered. They are: Z It shall provide sufficient gas to meet the maximum demand of the gas equipment. Piping must be sized to supply
GreenGuard Housewrap Installation Guide
000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be
Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013
Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems April 2013 The National Multi Housing Council and the National Apartment Association (NMHC/NAA) have
TEXAS STATE BOARD OF PLUMBING EXAMINERS EXAMINATION AND REGISTRATION Endorsement Training Programs
TITLE 22 PART 17 CHAPTER 363 RULE 363.11 EXAMINING BOARDS TEXAS STATE BOARD OF PLUMBING EXAMINERS EXAMINATION AND REGISTRATION Endorsement Training Programs (a) General requirements for Course Providers
SWIMMING POOL, SPA, & HOT TUB GUIDELINES
SWIMMING POOL, SPA, & HOT TUB GUIDELINES Pool permit cost is based on the total value of the project. See Permit Fee Schedule Table 1A. A. Adopted construction codes and installation requirements 1. 2015
CHAPTER 11 STORM DRAINAGE
CHAPTER STORM DRAINAGE SECTION PC 0 GENERAL 0. Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. Storm water discharge shall be
MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY. State Fire Marshal
MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY Policy #: Subject of Policy: INS-04 (2007) Escape Windows Revised and Approved By: Title: Jerry Rosendahl State Fire
PLAN SUBMITTAL REQUIREMENTS FOR KITCHEN HOOD AND DUCT EXTINGUISHING SYSTEMS
March 1996 PLAN SUBMITTAL REQUIREMENTS FOR KITCHEN HOOD AND DUCT EXTINGUISHING SYSTEMS PLAN REVIEW 1. Submit a completed permit application and a minimum of three sets of shopquality plans and calculations
The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:
Page 1 of 6 Section 1. PURPOSE This policy is an Engineering checklist of the Local Review Program for sanitary sewer improvement projects by the Bedford Regional Water Authority ( Authority ). Section
Session 7 Bivariate Data and Analysis
Session 7 Bivariate Data and Analysis Key Terms for This Session Previously Introduced mean standard deviation New in This Session association bivariate analysis contingency table co-variation least squares
TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST
TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST In order to provide a comprehensive plan review in a timely manner, and to insure the design and installation of fire alarm systems
CITY OF YORBA LINDA P.O. BOX 87014 CALIFORNIA 92885-8714
CITY OF YORBA LINDA P.O. BOX 87014 CALIFORNIA 92885-8714 BUILDING DIVISION (714) 961-7120 Single Family Residential New Construction, Additions & Alterations Submittal Requirements Required agency approvals
Area of Parallelograms, Triangles, and Trapezoids (pages 314 318)
Area of Parallelograms, Triangles, and Trapezoids (pages 34 38) Any side of a parallelogram or triangle can be used as a base. The altitude of a parallelogram is a line segment perpendicular to the base
SANITARY SEWER SPECIFICATIONS
SANITARY SEWER SPECIFICATIONS OCTOBER 2003 HARVEST-MONROVIA WATER, SEWER, AND FIRE PROTECTION AUTHORITY SECTION 1.00 1.10 Purpose The purpose of this document is to assemble the sewer specifications, policies,
Automatic Sprinkler System Calculations
SECTION FOUR CHAPTER 3 Automatic Sprinkler System Calculations Russell P. Fleming Introduction Applications Where Water Is Appropriate Water is the most commonly used fire extinguishing agent, mainly due
RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description
Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description The TYCO RAPID
Your Instructor. Two Biggest Obstacles to Residential Sprinklers. Two Biggest Obstacles to Residential Sprinklers
Residential Sprinklers ----- Issues and Answers Your Instructor Jeffrey M. Shapiro, PE Executive Director IRC Fire Sprinkler Coalition 1 2 The IRC Fire Sprinkler Coalition Not-for-profit association representing
Linear Programming Supplement E
Linear Programming Supplement E Linear Programming Linear programming: A technique that is useful for allocating scarce resources among competing demands. Objective function: An expression in linear programming
DESIGN GUIDE FOR INSTALLING PARTIAL SPRINKLER PROTECTION IN UNFINISHED BASEMENT AREAS
UP DESIGN GUIDE FOR INSTALLING PARTIAL SPRINKLER PROTECTION IN UNFINISHED BASEMENT AREAS March 2014 This document is not intended to advocate nor discourage the installation of residential sprinkler systems
FACILITY FIRE-SUPPRESSION WATER-SERVICE PIPING 21 11 00
211100_flexheadin_01_MS_0409 5/22/09 PTC 56 Lowland Street Holliston, MA 01746 Phone: (800) 829-6975 Phone: (508) 893-9596 Fax: (508) 893-6020 E-mail: [email protected] www.flexhead.com This MANU-SPEC
MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015
MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015 **Disclaimer: This document is to serve as informational purposes only. This is not a code book or a final interpretation of the
Request for Proposal # 2016-054
Request for Proposal # 2016-054 GIS Editing & Updating Services Due Date: July 7, 2016 Time: 2:00PM Receipt Location: Government Center, 500 N. Main Street, 7 th Floor, Room #709, Monroe, NC 28112 Procurement
I Gotta Know What? A Math Tutorial For Prospective CPO Students. FR = FA times FMR or FR = FA x FMR Volume (V)gallons = Volume (V)cubic feet x 7.
olume (V) = Area (A) x Average Depth (AD) I Gotta Know What? FR = FA times FMR or FR = FA x FMR Volume (V)gallons = Volume (V)cubic feet x 7.5 A = L x W A Math Tutorial For Prospective CPO Students AD
4 Installation Requirements
4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming
AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels
AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels AISI No. 1008 1010 1012 1015 1016 1017 1018 1019 1020 1021 1022 1023 1024 10 1026 1027 1029 10 1035 1036 1037 1038 1039 10 1041 1042 1043
SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS
SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS I. APPLICATION AND DEFINITIONS 1.01 Authorization for Standards 1.02 Application of Standards 1.03 Definitions
Bath Planning Guidelines With Access Standards
Bath Planning Guidelines With s 1: Door/Entry The clear opening of a doorway should be at least 32. This would require a minimum 2-10 door. If the existing structure precludes changing the opening then
505.3.6 For a building with a crawl space, see Figure 10. 505-1
505 WATER SERVICE INSTALLATION 505.1 DEFINITION A service line is comprised of the piping and related appurtenances including the connection installed from the Des Moines Water Works water main to the
Four Point Inspection
[email protected] Tampa Bay Area: Southwest Florida: (813) 368-6407 (239) 896-3986 Four Point Inspection Izzo, Frank & Jacqueline 3214 Williamsburg Street Sarasota, FL 34231 9/26/2013 Note to Policyholder:
6 3 The Standard Normal Distribution
290 Chapter 6 The Normal Distribution Figure 6 5 Areas Under a Normal Distribution Curve 34.13% 34.13% 2.28% 13.59% 13.59% 2.28% 3 2 1 + 1 + 2 + 3 About 68% About 95% About 99.7% 6 3 The Distribution Since
Engineering Specifications
PUREFLOW PEX PRODUCTS PART 1 GENERAL 1.1 SUMMARY 1.1.1 This specification covers Branch & Main, Parallel Water Distribution Systems (MANABLOC), Cross-linked Polyethylene tubing and fittings using PEX Press
2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
The Impact of Market Demands on Residential Post-Tensioned Foundation Design: An Ethical Dilemma
The Impact of Market Demands on Residential Post-Tensioned Foundation Design: An Ethical Dilemma Bart B. Barrett, B.S., P.E.1 Kerry S. Lee, M.B.A., P.E., M. ASCE2 Erik L. Nelson, Ph.D., P.E., M. ASCE3
Quick Reference ebook
This file is distributed FREE OF CHARGE by the publisher Quick Reference Handbooks and the author. Quick Reference ebook Click on Contents or Index in the left panel to locate a topic. The math facts listed
Solving Simultaneous Equations and Matrices
Solving Simultaneous Equations and Matrices The following represents a systematic investigation for the steps used to solve two simultaneous linear equations in two unknowns. The motivation for considering
WFTDA TRACK LAYOUT GUIDE
WFTDA TRACK LAYOUT GUIDE Updated March 2015 For use with Appendix A: WFTDA Track Design and Specifications MATERIALS REQUIRED: Tape measure (at least 100 feet or 30.48 meters) Marking tape, chalk, or some
REGISTRATION EXAMINATION, JUNE 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours
Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 99 REGISTRATION EXAMINATION, JUNE 009 PLUMBING INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed THREE
TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2.
May 3, 2013 Foam 138a 1. DESCRIPTION Chemguard Water Powered Oscillating Monitors are designed to automatically discharge over a specific design area upon system activation. These are suitable for use
Chapter 3 Installing Over-the-Post Railing on an L-Shaped Stair
49 Chapter 3 Installing Over-the-Post Railing on an L-Shaped Stair In this chapter: The Over-the-Post Balustrade System Determining the Rail Centerline Using Rail Bolts Making a Pitch Block Laying Out
Lesson 3.1 Factors and Multiples of Whole Numbers Exercises (pages 140 141)
Lesson 3.1 Factors and Multiples of Whole Numbers Exercises (pages 140 141) A 3. Multiply each number by 1, 2, 3, 4, 5, and 6. a) 6 1 = 6 6 2 = 12 6 3 = 18 6 4 = 24 6 5 = 30 6 6 = 36 So, the first 6 multiples
Pressure Limiting Driver (PLD)
Pressure Limiting Driver (PLD) Discharge Pressure Control Suction Pressure Control June 9 2009 Mark Evans Clarke Fire Protection Products Justin Strousse Clarke Fire Protection Products Overview Discharge
Lawn Sprinkler Systems Reserve Irrigation Inc. O & M. Version 2009 1382 Roseland Drive Macedonia, Ohio 44056 800.435.4979 www.rilawnsprinklers.
Lawn Sprinkler Systems Reserve Irrigation Inc. O & M Version 2009 1382 Roseland Drive Macedonia, Ohio 44056 800.435.4979 Table of Contents Spring Maintenance of Irrigation system Page 1-9 Summer Maintenance
Exhaust Calculation Booklet
Exhaust Calculation Booklet American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 e-mail: [email protected] ADC Part No. 450450 Exhaust
1. Kyle stacks 30 sheets of paper as shown to the right. Each sheet weighs about 5 g. How can you find the weight of the whole stack?
Prisms and Cylinders Answer Key Vocabulary: cylinder, height (of a cylinder or prism), prism, volume Prior Knowledge Questions (Do these BEFORE using the Gizmo.) [Note: The purpose of these questions is
CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT
Page 1 CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT CIVIC CENTRE 2141 MAJOR MACKENZIE DRIVE MAPLE ONTARIO L6A 1T1 905-832-2281 Page 2 SECTION 1 - GENERAL OBJECTIVES To provide
BUILDING PERMIT SPECIFICATIONS
BUILDING PERMIT SPECIFICATIONS The below noted requirements are based upon La Plata County Building Code. These specifications are not intended as a complete set of requirements, but are intended to provide
Pipe Sizes For Water Distribution System Design
Appendix D Pipe Sizes For Water Distribution System Design D-. This appendix contains information to help determine pipe sizes when designing a water distribution system. Use Table D- and Tables D- through
POST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
Window Glass Design 5 According to ASTM E 1300
A User s Guide to: Window Glass Design 5 According to ASTM E 1300 A product of: 1 Table of Contents Table of Contents List of Figures Chapter 1: Window Glass Design 5 1.1 Introduction 1.2 Features ii iv
THE DEWALT RAFTER SQUARE
THE DEWALT RAFTER SQUARE The DEWALT Rafter Square is designed to provide a quick, accurate, and repeatable means for laying out and cutting the various cuts on common, hip, valley and jack rafters used
SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA 95728-1039 (7300 Short Road, Serene Lakes)
SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA 95728-1039 (7300 Short Road, Serene Lakes) Maintenance Office Administrative Office Billing Office 530-426-7802 530-426-7800 916-332-4872
How To Install A Carbon Monoxide Detector
NASSAU COUNTY FIRE COMMISSION OFFICE OF THE FIRE MARSHAL Nassau County Public Safety Center 1194 Prospect Avenue Westbury, New York 11590 (516) 573-9900 / nassaucountyny.gov Chief Fire Marshal Scott D.
Geometry and Measurement
The student will be able to: Geometry and Measurement 1. Demonstrate an understanding of the principles of geometry and measurement and operations using measurements Use the US system of measurement for