120V AC Smoke Alarm with 9V Battery Back-up
|
|
|
- Vanessa Osborne
- 9 years ago
- Views:
Transcription
1 L OF FIRE V I 2005 Invensys Controls Americas 120V AC Smoke Alarm with 9V Battery Back-up PHOTOELECTRIC MODEL FPAD C PLEASE READ AND SAVE THIS MANUAL Installer: Please leave this manual with the product. STATE I S T I N G CALIFORNIA S STATE E R E MARSH AL C Photoelectric alarms are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. Ionization alarms are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include flammable liquids or paper burning in a waste container. However, both types of alarms provide adequate detection of both types of fires. If you desire the earliest detection of both smoldering fires and fast flaming fires, you should install smoke alarms that combine both photoelectric and ionization sensing technologies in one unit. SMOKE ALARM FEATURES This smoke alarm is powered by 120V AC (0.05 Amps, 60Hz) and a 9-volt battery back-up source. AC/DC smoke alarms offer added protection in the event of a power failure or a drained battery. Unique power connector prevents interconnection with incompatible smoke alarms or security systems. This smoke alarm may be interconnected with as many as 11 additional Firex model AD, ADC, PAD, FADC and FPAD smoke alarms, and/or as many as 6 Firex model ADH heat alarms for a total of not more than 18 interconnected devices. Optional tamper-resist feature can serve as a safeguard against tampering. Unique battery missing lockout. The smoke alarm battery door will not close if a battery is not in the battery pocket. Separate green and red LEDs indicate that the smoke alarm is receiving AC power, working under normal operation, or in alarm. Loud alarm horn 85 decibels at 10 feet sounds to alert you to an emergency. This alarm incorporates the internationally recognized horn signal for evacuation. During alarm mode, the horn produces three short beeps followed by a 2 second pause and then repeats. This pattern is somewhat different than the previous alarm sound, which continually beeped. Test button checks smoke alarm operation. IMPORTANT SAFETY INFORMATION PLEASE READ AND SAVE THESE INSTRUCTIONS W A R N I N G This smoke alarm requires constant 120-volt, AC power AND a working 9-volt battery to operate properly. This smoke alarm WILL NOT work if AC power is not connected or has failed or been interrupted for any reason AND the battery is removed, drained or improperly connected. DO NOT use any other kind of battery except as specified in this manual. DO NOT connect this smoke alarm to any other type of smoke alarm or auxiliary device, except those listed in this manual. DO NOT remove or disconnect battery or turn off AC power to quiet unwanted alarms. This will remove your protection. Open windows or fan the air around smoke alarm to silence it. The Push-to-Test button accurately tests all smoke alarm functions. DO NOT use any other test method. Test smoke alarm weekly to ensure proper operation. This smoke alarm should be installed only by a licensed, qualified electrician. Observe and follow all local and national electrical and building codes for installation. This smoke alarm IS NOT designed to be the PRIMARY protection for buildings that require complete fire alarm systems. Buildings of this type include hotels, motels, dormitories, hospitals, nursing homes, and group homes. This is true even if they were once single family homes. However, this 1
2 smoke alarm MAY be used inside individual rooms as SUPPLEMENTAL protection. Smoke alarms must not be used with detector guards unless the combination of alarm and guard has been evaluated and found suitable for that purpose. Install a smoke alarm in every room and on every level of the home. Smoke may not reach the smoke alarm for many reasons. For example, if a fire starts in a remote part of the home, on another level, in a chimney, wall, roof, or on the other side of a closed door, smoke may not reach the smoke alarm in time to alert household members. A smoke alarm will not promptly detect a fire EXCEPT in the area or room in which it is installed. Interconnected smoke alarms installed in every room and on every level of the household offer maximum protection. The National Fire Protection Agency (NFPA) recommends interconnecting smoke alarms so that when one smoke alarm senses smoke and sounds its alarm, all others will sound as well. Do not interconnect smoke alarms from one individual family living unit to another. Do not connect this smoke alarm to any other type of alarm or auxiliary device. Smoke alarms may not alert every household member every time. The alarm horn is loud in order to alert individuals to a potential danger. However, there may be limiting circumstances where a household member may not hear the alarm (i.e., outdoor or indoor noise, sound sleepers, drug or alcohol usage, the hard of hearing, etc.). If you suspect that this smoke alarm may not alert a household member, install and maintain specialty smoke alarms. Household members must hear the alarm s warning sound and quickly respond to it to reduce the risk of damage, injury, or death that may result from fire. If a household member is hard of hearing, install special smoke alarms with lights or vibrating devices to alert occupants. Smoke alarms can sound their alarms only when they detect smoke. Smoke alarms detect combustion particles in the air. They do not sense heat, flame, or gas. This smoke alarm is designed to give audible warning of a developing fire. However, many fires are fast-burning, explosive, or intentional. Others are caused by carelessness or safety hazards. Smoke may not reach the smoke alarm QUICKLY ENOUGH to ensure safe escape. Smoke alarms have limitations. This smoke alarm is not foolproof and is not warranted to protect lives or property from fire. Smoke alarms are not a substitute for insurance. Homeowners and renters should insure their lives and property. In addition, it is possible for the smoke alarm to fail at any time. For this reason, you must test the smoke alarm weekly and replace every 10 years. SMOKE ALARM PLACEMENT Invensys Controls Americas recommends complete coverage protection achieved by installing a smoke alarm in every room of your home. The National Fire Protection Association s (NFPA) minimum requirement, as stated in Standard 72, Chapter 2, reads as follows: Smoke detectors shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding crawl spaces and unfinished attics. In new construction a smoke detector also shall be installed in each sleeping room. Chapter 2 also reads as follows: In new construction, where more than one smoke detector is required by 2-2.1, they shall be so arranged that operation of any smoke detector shall cause the alarm in all smoke detectors within the dwelling to sound. The NFPA, 1993 Edition, Appendix A further states: The required number of smoke detectors may not provide reliable early warning protection for those areas separated by a door from the areas protected by the required smoke detectors. For this reason, it is recommended that the householder TV consider the use of additional smoke detectors for those areas for increased protection. The additional areas include: basement, bedrooms, dining room, furnace room, utility room, and hallways not protected by the required smoke detectors. Also, as required by the California State Fire Marshal: Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the house- 2 DINING LIVING LIVING BASEMENT DINING KITCHEN HALL LIVING KITCHEN DINING
3 hold as follows: A smoke detector installed in each separate sleeping area (in the vicinity, but outside the bedrooms), and heat or smoke detectors in the living rooms, dining rooms, bedrooms, kitchens, hallways, attics, furnace rooms, closets, utility and storage rooms, basements and attached garages. FOR BEST PROTECTION, WE RECOMMEND THAT YOU INSTALL A SMOKE ALARM IN EVERY. In addition, we recommend that all smoke alarms be interconnected. Typical Efficiency Home (Apartment) Install a smoke alarm on the SLEEPING KITCHEN AREA LIVING AREA ceiling or wall closest to the sleeping area. EFFICIENCY APARTMENT BATH KITCHEN LIVING MOBILE HOME Typical Mobile Home NOTE: For mobile homes built before 1978, install smoke alarms on an inside wall between 4 and 12 inches from the ceiling. (Older mobile homes have little or no insulation in the ceiling.) This is especially important if the ceiling is unusually hot or cold. Install a smoke alarm inside each bedroom and in the hallway outside each separate sleeping area. Typical Single-Story Home Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area. If a bedroom area hallway is more than 30 feet long, BED- KITCHEN BATH install a smoke alarm at each end. If there is a basement: FURNACE Install a smoke alarm on the basement ceiling at the bottom of the BASEMENT ROOOM stairwell. Typical Two-Story or Split Level Home LIVED-IN ATTIC Install a smoke alarm on the ceiling or wall inside each bedroom BATH and in the hallway outside each separate sleeping area. If a bedroom area hallway is more than LIVING AREA KITCHEN 30 feet long, install a smoke alarm at each end. FURNACE Install a smoke alarm at the top of BASEMENT a first-to-second floor stairwell. TWO STORY If there is a basement: Install a smoke alarm on the basement ceiling at the bottom of the stairwell. KEY Smoke Alarm (Ionization) Photoelectric Smoke Alarm or Ionization Smoke Alarm with False Alarm Control IMPORTANT SMOKE ALARM PLACEMENT AND EXCEPTION INFORMATION Install a smoke alarm as close to 4 IN CEILING (0.1m ) the center of the ceiling as possible. If this is not practical, mount ACCEPTABLE HERE (0.1m ) 4 IN MINIMUM no closer than 4 inches from a NEVER HERE 12 IN (0.3 m ) wall or corner. Also, if local codes MAXIMUM TOP OF DETECTOR ACCEPTABLE HERE allow, install smoke alarms on walls, between 4 and 12 inches SIDE WALL from ceiling/wall intersections. Install a minimum of two smoke alarms in every home, no matter how small the home. New construction codes require a minimum of two interconnected smoke alarms in newly built homes. Install a smoke alarm in each room SOFFIT 24" that is divided by a partial wall (either coming down from the ceiling at least 24 inches, or coming up STUB WALL from the floor). 3
4 Install smoke alarms on peaked, cathedral, ACCEPTABLE IN THIS AREA or gabled ceilings 3 feet from the highest PEAKED CEILING point (measured horizontally). NFPA 72, Section states: A row of detectors shall first be spaced at or within 3 feet (0.9 m) of the peak of the ceiling, measured horizontally. Install a smoke alarm in lived-in attics or attics which house electrical equipment like furnaces, air conditioners, or heaters. DO NOT install smoke alarms: Near appliances or areas where normal combustion regularly occurs (kitchens, near furnaces, hot water heaters). Use specialized smoke alarms with unwanted alarm control for these areas. In areas with high humidity, like bathrooms or areas near dishwashers or washing machines. Install at least 10 feet (3 meters) away from these areas, if possible. Near air returns or heating and cooling supply vents. Install at least 3 feet (0.9 meters) away from these areas. The air could blow smoke away from the detector, interrupting its alarm. In rooms where temperatures may fall below 40 F (4 C) or rise above 100 F (38 C). In extremely dusty, dirty, or insect-infested areas. Loose particles interfere with smoke alarm operation. HOW TO INSTALL THIS SMOKE ALARM DANGER: ELECTRICAL SHOCK HAZARD. Turn off power at the main fuse box or circuit breaker by removing the fuse or switching the circuit breaker to the OFF position. WARNING: This smoke alarm should be installed only by a qualified electrician. Smoke alarm installation must be in accordance with the requirements of Article 760 of the National Electrical Code and any local codes that may apply. THIS SMOKE ALARM SHOULD BE INSTALLED IN ACCOR- DANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIA- TION S STANDARD 72 (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269). Install smoke alarm on a 4-inch octagon or single gang junction box only. 1. From back of smoke alarm, remove mounting plate. (To later engage tamper-resist feature, twist out and set aside one of the pins molded into plate. Both pins are exactly the same.) 2. Align recessed slots on plate with mounting holes of a 4- inch octagon or single gang junction box. 3. Gently pull household wires through center hole of plate. 4. Secure plate to junction box with mounting screws. 5. With a small wire connector, connect white wire from connector plug to white household wire. 6. Connect black wire from connector plug to black household wire. 7. If interconnection is desired, connect yellow wire from connector to interconnect wire between smoke alarms. See section INTERCONNECTING SMOKE ALARMS. NOTE: If this will be a single-station smoke alarm, cover yellow wire with electrical tape and tuck into Battery junction box. FPAD 8. Attach connector plug to pins on back of smoke alarm. Plug will only fit one way and will snap into place. 9. Gently tug connector to be sure it is attached securely. Battery Door Remove thin plastic 4
5 10. Position smoke alarm to mounting plate and turn clockwise to lock into place. For tamper-resist, use long-nosed pliers to remove thin plastic Insert pin here Remove pin from here from notch on smoke alarm edge. Insert pin into notch on edge of smoke alarm after smoke alarm is positioned properly in base. 11. If the alarm has a red arrow tab in the battery compartment, remove it and close the battery door. If not, just close the battery door. Smoke alarm may beep briefly as door is closed. 12. Turn on power at main fuse box or circuit breaker. 13. Test smoke alarm. See TESTING THE SMOKE ALARM. INTERCONNECTING SMOKE ALARMS FOR INTERCONNECT LINE ONLY use #14-#18 AWG minimum solid or stranded wire. When interconnecting, maximum wire length between any two is 1,500 feet for #18 AWG or 4,000 feet for #14 AWG (20 OHMS loop resistance). This smoke alarm may be interconnected with as many as 11 additional Firex model AD, ADC, PAD, FADC, and FPAD smoke alarms, and/or as many as 6 Firex model ADH heat alarms for a total of not more than 18 interconnected devices. DO NOT connect to any type or model smoke alarm. Connect smoke alarms to a single AC branch circuit. If local codes do not permit, be sure the neutral wire is common to both phases. WHITE WHITE WHITE YELLOW YELLOW BLACK BLACK BLACK TO NEUTRAL TO 120 VAC FOR INTERCONNECT: USE # 18 AWG MINIMUM WIRE RED AND GREEN LED INDICATORS This smoke alarm features separate red and green LED indicators. The LEDs indicate the following: GREEN CONSTANT ON GREEN OFF RED blinks once a minute RED blinks once a second AC power is present. AC power is not present. Indicating presence of a working battery. Smoke alarm senses smoke and simultaneously sounds an audible alarm. RED OFF Another smoke alarm in the network has sensed smoke and is signalling this alarm. (Interconnected system only) TESTING THE SMOKE ALARM W A R N I N G Test each smoke alarm to be sure it is installed correctly and operating properly. Test all smoke alarms in an interconnected system after installation. The Push-to-Test button accurately tests all functions. DO NOT use an open flame to test this smoke alarm. You may ignite and damage the smoke alarm or your home. Test smoke alarms weekly and upon returning from vacation or when no one has been in the household for several days. Stand at arm s length from the smoke alarm when testing. The alarm horn is loud to alert you to an emergency and can be harmful to hearing. Test all smoke alarms weekly by doing the following: 1. Observe the green LED. A constant green light indicates the smoke alarm is receiving 120V AC power. 2. Firmly depress the Push-to-Test button for at least five (5) seconds. The smoke alarm will sound 3 short beeps followed by a 2-second pause and then repeats. The alarm may sound for up to 10 seconds after releasing the Push-to-Test button. NOTE: If smoke alarms are interconnected, all smoke alarms should sound an alarm within three seconds after any test button is pushed and the tested smoke alarm sounds. 5
6 3. If smoke alarm does not sound, turn off power at main fuse box or circuit breaker and check wiring. Retest smoke alarm. REPLACE OR RETURN THE ALARM IF THE PUSH-TO-TEST FUNCTION DOES NOT OPERATE PROPERLY AFTER FOLLOWING THE PROCEDURES OUTLINED ABOVE (see REPAIR below). DANGER: If alarm horn sounds, and smoke alarm is not being tested, the smoke alarm is sensing smoke. THE SOUND OF THE ALARM HORN REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION. MAINTENANCE AND CLEANING In addition to weekly testing, this smoke alarm requires yearly battery replacement and periodic cleaning to remove dust, dirt, and debris. DANGER: ELECTRICAL SHOCK HAZARD. Turn off power at main service panel by removing fuse or switching appropriate circuit breaker to OFF position before replacing battery or cleaning smoke alarm. BATTERY REPLACEMENT Always turn off power to smoke alarm before replacing battery. Replace battery at least once a year or immediately when the low battery chirp sounds once a minute, even though the smoke alarm is receiving AC power. In a low battery condition, the red LED will blink once per minute followed immediately by a short, audible chirp indicating the battery is low and needs to be replaced immediately. Use only the following batteries as replacements in this smoke alarm: Eveready 522 or 1222, Duracell MN 1604 or Ultralife U9VL-J. WARNING: DO NOT USE ANY OTHER TYPE OF BATTERY, EXCEPT AS SPECIFIED IN THIS MANUAL. DO NOT USE RECHARGEABLE BATTERIES. 1. Turn off power to smoke alarm at main service panel. 2. Slide battery door open as shown on page 4 in the installation section. 3. Remove drained battery from compartment and discard. 4. Install a fresh 9-volt battery, observing correct polarity. 5. Slide battery door closed. 6. Turn on power and test smoke alarm using Push-to-Test button. CLEANING Clean the smoke alarm at least once a month to remove dust, dirt, or debris. Always turn off power to smoke alarm before cleaning. Using the soft brush or wand attachment to a vacuum cleaner, vacuum all sides and cover of smoke alarm. Be sure all the vents are free of debris. If necessary, turn off power and use a damp cloth to clean smoke alarm cover. IMPORTANT: Do not attempt to remove the cover or clean inside the smoke alarm. THIS WILL VOID YOUR WARRANTY. REPAIR CAUTION: Do not attempt to repair this smoke alarm. Doing so will void your warranty. If smoke alarm is not operating properly, see TROUBLESHOOTING. If necessary and if still under warranty, return smoke alarm to Invensys Controls Americas. Pack it in a well-padded carton, shipping prepaid, to: Invensys Controls Americas Product Service Department 28C Leigh Fisher Blvd. El Paso, TX If the smoke alarm is no longer under warranty, have a licensed electrician replace the smoke alarm immediately with a comparable Firex brand smoke alarm. PRACTICE FIRE SAFETY If the smoke alarm sounds its alarm horn, and you have not pushed the test button, it is warning of a dangerous situation. Your immediate response is necessary. To prepare for such occurrences, develop family escape plans, discuss them with ALL household members, and practice them regularly. Expose everyone to the sound of a smoke alarm and explain what the sound means. Determine TWO exits from each room and an escape route to the outside from each exit. Teach all household members to touch the door and use an alternate exit if the door is hot. INSTRUCT THEM NOT TO OPEN THE DOOR IF THE DOOR IS HOT. 6
7 Teach household members to crawl along the floor to stay below dangerous smoke, fumes, and gases. Determine a safe meeting place for all members outside the building. WHAT TO DO IN CASE OF A FIRE 1. Don t panic; stay calm. 2. Leave the building as quickly as possible. Touch doors to feel if they are hot before opening them. Use an alternate exit if necessary. Crawl along the floor, and DO NOT stop to collect anything. 3. Meet at a pre-arranged meeting place outside the building. 4. Call the fire department from OUTSIDE the building. 5. DO NOT GO BACK INSIDE A BURNING BUILDING. Wait for the fire department to arrive. These guidelines will assist you in the event of a fire. However, to reduce the chance that fires will start, practice fire safety rules and prevent hazardous situations. DANGER: WARNING: TROUBLESHOOTING Always turn off power at main fuse box or circuit breaker before taking trouble- shooting action. DO NOT disconnect battery or AC power to quiet an unwanted alarm. This will remove your protection. Fan the air or open a window to remove smoke or dust. PROBLEM Smoke alarm does not sound when tested. NOTE: Push test button for at least five (5) seconds while testing LED blinks and alarm beeps simultaneously every 60 seconds. SOLUTION 1. Check that AC power is turned on. 2. Turn off power. Remove smoke alarm from mounting plate and check that connector plug is securely attached. 3. Clean smoke alarm. Battery is low REPLACE IT IMMEDIATELY LED blinks and 30 seconds Unit inoperable. REPLACE later alarm beeps repeats at OR RETURN FOR REPAIR 60 second intervals. IMMEDIATELY The alarm is operating cor- rectly. This alarm features the internationally recognized horn signal for evacuation. The horn pattern is 3 short beeps followed by a 2 second pause and then repeats. Smoke alarm beeps about once a minute. Smoke alarm sounds unwanted alarms intermittently or when residents are cooking, taking showers, etc. Interconnected smoke alarms do not sound when system is tested. The alarm sounds different than I m used to. It starts and stops. Turn off power and replace battery. See Battery Replacement in the MAINTENANCE AND CLEANING section. 1. Clean smoke alarm. See Cleaning in the MAINTENANCE AND CLEANING section 2. Hire an electrician to move smoke alarm to a new location. See SMOKE ALARM PLACEMENT Press and hold test button for at least three seconds after the first unit sounds. REPLACE OR RETURN THE ALARM IF THE PUSH-TO-TEST FUNCTION DOES NOT OPERATE PROPERLY AFTER FOLLOWING THE PROCEDURES OUTLINED ABOVE (see REPAIR on page 6). 7
8 WARRANTY INFORMATION 5-YEAR LIMITED SMOKE ALARM WARRANTY AND 10-YEAR LIMITED ULTRALIFE U9VL-J LITHIUM BATTERY WARRANTY (WHEN SOLD WITH INVENSYS CONTROL AMERICAS SMOKE ALARM) Invensys Controls Americas warrants to the original consumer purchaser each new smoke alarm to be free from defects in material and workmanship under normal use and service for a period of five (5) years from the date of purchase. For Invensys Controls Americas smoke alarms sold with an Ultralife U9VL-J 9-volt battery, Invensys Controls Americas warrants to the original consumer purchaser each new Ultralife U9VL-J 9-volt battery to be free from defects in material and workmanship under normal use and service for a period of ten (10) years from the date of purchase. Invensys Controls Americas agrees to repair or replace, at its option, any defective smoke alarm or Ultralife U9VL- J 9-volt battery (when sold with Invensys Controls Americas smoke alarm) provided that it is returned with postage prepaid and with proof of purchase date to Invensys Controls Americas. This warranty does not cover damage resulting from accident, misuse or abuse or lack of reasonable care of the product. This warranty is in lieu of all other express warranties, obligations or liabilities. THE IMPLIED WARRANTIES OF MER- CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO A PERI- OD OF FIVE (5) YEARS FOR THE SMOKE ALARM AND TEN (10) YEARS FOR THE ULTRALIFE LITHIUM U9VL-J 9-VOLT BATTERY (WHEN SOLD WITH INVENSYS CON- TROLS AMERICAS SMOKE ALARM) FROM PURCHASE DATE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. IN NO CASE SHALL INVENSYS CONTROLS AMERICAS BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY ITS NEGLIGENCE OR FAULT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other legal rights which vary from state to state. This smoke alarm s manufacture and distribution are licensed by the U.S. Nuclear Regulatory Commission. This product meets all the requirements of U.L. Standard 217. Controls Americas 191 E. North Avenue Carol Stream, Illinois United States of America C 8
Smoke Alarm 120V AC. Smoke Alarm. Back-up. with 9V Battery IONIZATION MODELS AD, ADC PHOTOELECTRIC MODEL PAD
1999 Maple Chase Company 120V AC Smoke Alarm with 9V Battery Back-up Smoke Alarm IONIZATION MODELS AD, ADC PHOTOELECTRIC MODEL PAD PLEASE READ AND SAVE THIS MANUAL Installer: Please leave this manual with
120V AC Smoke Alarm with 9V Battery. Back-up IONIZATION MODEL ADC
OF FIRE V I 120V AC Smoke Alarm with 9V Battery Back-up IONIZATION MODEL ADC PLEASE READ AND SAVE THIS MANUAL Installer: Please leave this manual with the product. 110-762F L STATE I S T I N G CALIFORNIA
Smoke Alarm User s Manual
V-MUL-007-A(A0) Smoke Alarm User s Manual Please read and save this manual PHOTOELECTRIC SMOKE ALARM MODEL: VST-S598I Class II Apparatus Photoelectric smoke alarms are generally more effective at detecting
User Guide. PLEASE READ AND SAVE INSTALLER: Please leave this user guide with the product.
User Guide KF10 KF10LL KF10R Ionisation KF20 KF20LL KF20R Optical EN14604:2005 LICENSE NO. KM 524754 0086-CPD-535595 14 EN 14604:2005 PLEASE READ AND SAVE INSTALLER: Please leave this user guide with the
INSTALLATION AND OPERATION MANUAL
Photoelectronic Smoke Detector with Built-in Wireless Transmitter INSTALLATION AND OPERATION MANUAL 1 Model # 1008-4 What smoke detectors can do: Smoke detectors are designed to provide early warning of
Visit Us on the Web! www.smokealarms.com MODEL USI-1122L LONG LIFE* LITHIUM POWERCELL SMOKE & FIRE ALARM WITH SILENCE CONTROL
Visit Us on the Web! www.smokealarms.com MODEL USI-1122L LONG LIFE* LITHIUM POWERCELL SMOKE & FIRE ALARM WITH SILENCE CONTROL READ ALL INSTRUCTIONS The smoke alarm has a recommended service life of at
2-WAY WIRELESS SUPERVISED PHOTOELECTRIC SMOKE DETECTOR. Model: EL-4703 INSTALLATION INSTRUCTIONS
2-WAY WIRELESS SUPERVISED PHOTOELECTRIC SMOKE DETECTOR Model: EL-4703 INSTALLATION INSTRUCTIONS GENERAL DESCRIPTION Electronics Line's smoke detector is single station, photoelectric smoke detector with
READ ALL INSTRUCTIONS
Visit Us on the Web! www.smokealarms.com MODEL SS-770/SS-771 SMOKE & FIRE ALARM READ ALL INSTRUCTIONS The smoke alarm has a recommended service life of at least 10 years under normal conditions. The smoke
User s Manual General Use Smoke Alarm Cat. SA67C, SA67B
INSIDE THIS MANUAL User s Manual General Use Smoke Alarm Cat. SA67C, SA67B Ionization smoke alarms are generally more effective at detecting flaming fires which consume combustible materials rapidly and
MODEL USI-1203/USI-1204 (Part #USI-1203HA/USI-1204HA) COMMERCIAL RESIDENTIAL (UTHA) SMOKE & FIRE ALARM WITH SILENCE CONTROL
MODEL USI-1203/USI-1204 (Part #USI-1203HA/USI-1204HA) COMMERCIAL RESIDENTIAL (UTHA) SMOKE & FIRE ALARM WITH SILENCE CONTROL READ ALL INSTRUCTIONS The smoke alarm has a recommended service life of at least
SMOKE/CARBON MONOXIDE ALARM MODEL FADCQ
2002 INVENSYS CLIMATE CONTROLS AMERICAS SMOKE/CARBON MONOXIDE ALARM MODEL FADCQ PLEASE READ AND SAVE THIS MANUAL Installer: Please leave this manual with the product 110-1050 The ionization type alarms
IMPORTANT! PLEASE READ CAREFULLY AND SAVE.
USER S MANUAL SMOKE ALARM Model SA00 Model SA0 and Model SA05 With Silence Feature IMPORTANT! PLEASE READ CAREFULLY AND SAVE. This user s manual contains important information about your Smoke Alarm s
USER S MANUAL TABLE OF CONTENTS INTRODUCTION. SMOKE ALARM WITH TEN-YEAR NON-REPLACEABLE LITHIUM POWERCELL Model SA340
USER S MANUAL SMOKE ALARM WITH TEN-YEAR NON-REPLACEABLE LITHIUM POWERCELL Model SA340 IMPORTANT! PLEASE READ CAREFULLY AND SAVE. This user s manual contains important information about your Smoke Alarm
120V AC Ionization Smoke Alarm
F FIRE 120V AC Ionization Smoke Alarm 110-427K MDEL G-6, H, GC PG40 and FXW-R L STATE I S T I N G CALIFRNIA S STATE E R V MARSH AL I E C PLEASE READ AND SAVE THIS MANUAL Installer: Please leave this manual
USER S MANUAL BATTERY POWERED SMOKE ALARM. Model FG225 Model FG250
USER S MANUAL BATTERY POWERED SMOKE ALARM Model FG225 Model FG250 IMPORTANT! PLEASE READ CAREFULLY AND SAVE. This user s manual contains important information about your Smoke Alarm s operation. If you
Smoke Alarm User s Guide
10Y29 For model: 10Y29 Smoke Alarm User s Guide Lithium (non-replaceable sealed in) Battery-Operated Optical Smoke Alarm with HUSH TM Control to temporarily silence nuisance alarms. Thank you for purchasing
MODEL MI3050S. UNIVERSAL SMOKE SENSING TECHNOLOGY 2-in-1 SMOKE & FIRE ALARM WITH 10 YEAR PERMANENT POWER SEALED BATTERY
Conforms to UL Std. 217 MODEL MI3050S Single Station Smoke Alarm UNIVERSAL SMOKE SENSING TECHNOLOGY 2-in-1 SMOKE & FIRE ALARM WITH 10 YEAR PERMANENT POWER SEALED BATTERY READ ALL INSTRUCTIONS THANK YOU
DOMESTIC SMOKE ALARMS
SOUTH AUSTRALIAN METROPOLITAN FIRE SERVICE HOME FIRE SAFETY INFORMATION For further advice contact the Community Safety Department South Australian Metropolitan Fire Service on 8204 3611 DOMESTIC SMOKE
Ionisation Smoke Alarm
0945-7204-00.qxd:_ 2009.7.31 4:25 PM Page Ionisation Smoke Alarm Manual Model Q945 Ionisation smoke alarms are designed to detect invisible particles (associated with fast flaming fires). Home fires develop
USER S MANUAL SMOKE ALARMS
US Patent 6,377,182 Printed in Mexico M08-000-000 Q 09/03 USER S MANUAL SMOKE ALARMS AC Powered Photoelectric Smoke Alarm with Battery Back-Up and Silence Feature Model 7010B Input: 120V AC ~, 60Hz, 0.04A
Ionization alarms are best suited for rooms, which contain highly combustible material. These types of material include:
Smoke Detector University Most people are aware of the danger of fire but are unaware of the fatality of smoke. More people die from breathing smoke than by burns. In fact, deaths from smoke inhalation
Smoke Alarm User s Guide
SIGNALING U L LISTED Smoke Alarm User s Guide i4618a, i4718a, i5000a Series Model: i4618a 120 Volt Smoke Alarm with 9 Volt Battery Back-up Front Load Battery Test and Hush Button ATTENTION: Please take
USER S MANUAL SMOKE ALARMS
USER S MANUAL SMOKE ALARMS AC Powered Photoelectric Smoke Alarm with Battery Back-Up and Silence Feature Model 7010B Input: 120V AC ~, 60Hz, 0.04A AC Powered Photoelectric Smoke Alarm with Silence Feature
SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective
SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective The National Fire Alarm Code, NFPA 72, sets the minimum requirements of performance, selection, use and location of automatic detection
1235CA 1275CA PE120CA
Smoke Alarm M a n u a l For alarm models: 1235CA 1275CA PE120CA SINGLE AND/OR MULTIPLE STATION SMOKE ALARM C o n t e n t s Introduction........................ 1 Installation..........................
USER S MANUAL Smoke Alarms
USER S MANUAL Smoke Alarms AC Powered Ionization Smoke Alarm with Silence and Latching Features Model 90 Input: 0V AC ~, 60 Hz, 0.0A AC Powered Ionization Smoke Alarm with Battery Back-up, Silence and
Smoke Alarm User s Guide
SIGNALING U L LISTED Smoke Alarm User s Guide Model: i9030, i9040, i9040rv i9050, i9060, i9060rv and i9080 i9030 i9040 and i9040rv i9050 i9060 and i9060rv i9080 9 Volt Battery Operated ATTENTION: Please
USER S MANUAL SMOKE ALARMS
USER S MANUAL SMOKE ALARMS Battery Powered Photo & Ion Smoke Alarm Model SA30 with Silence All First Alert and BRK Smoke Alarms conform to regulatory requirements, including UL7 and are designed to detect
www.ealarm.com.my P/N 5-051-371-00 Rev D
System 236 System 236i P/N 5-051-371-00 Rev D Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced alarm systems on the market today, designed to provide
10 YEAR LIFE SMOKE ALARM
User Manual 10 YEAR LIFE SMOKE ALARM ST-620 Please read me as I could save your life. Please retain this user manual for future reference CONTENTS INTRODUCTION 2 ALARM SMART SILENCE 11 AUTOMATIC POWER
FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK
FIREPLACE HEATER FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK If you have any questions about the operation of your fireplace heater, please contact Crane Customer Care. Toll Free: 888-599-0992
Smoke Alarm. Manual. i12020aca i12040aca PE120CA. For alarm models:
Smoke Alarm Manual For alarm models: i12020aca i12040aca PE120CA Manual P/N 820-1193 Rev C 1235-7219-04 Note: This alarm has a low battery HUSH feature. If the alarm is sounding a low battery warning chirp,
Smoke Alarm User s Guide
i12020a i12040a i12080a For models: i12020a, i12040a, i12080a Smoke Alarm User s Guide AC Wire-in Single and/or Multiple Station (up to 24 Devices) Ionization Smoke Alarm with HUSH TM Control to temporarily
READ AND SAVE THIS USER S GUIDE
RF-SM-ACDC Wireless Smoke Alarm Hardwire with battery back-up SIGNALING U L LISTED Thank you for purchasing a Kidde Wireless AC Powered Smoke Alarm, part of the Kidde Wireless System. It is an important
Wireless Smoke Alarm User s Guide
RF-SM-DC For model: RF-SM-DC Wireless Smoke Alarm User s Guide Battery powered, wireless Smoke Alarm with SMART HUSH Control to temporarily silence nuisance alarms. Thank you for purchasing a Kidde Wireless
Wireless Smoke Alarm User s Guide
RF-SM-ACDC For model: RF-SM-ACDC Wireless Smoke Alarm User s Guide Wireless Smoke Alarm with SMART HUSH Control to temporarily silence nuisance alarms and battery backup. Thank you for purchasing a Kidde
SINGLE-STATION PHOTOELECTRIC SMOKE DETECTOR SD-738/w USER S MANUAL
SINGLE-STATION PHOTOELECTRIC SMOKE DETECTOR SD-738/w USER S MANUAL TABLE OF CONTENTS INTRODUCTION... 1 LOCATIONS TO INSTALL YOUR SMOKE DETECTOR... 1 LOCATIONS NOT TO INSTALL YOUR SMOKE DETECTORS... 2 INSTALLING
527 CMR: BOARD OF FIRE PREVENTION REGULATIONS
527 CMR 24.00: FIRE WARNING SYSTEMS INSTALLED IN BUILDINGS WITHIN THE COMMONWEALTH OF MASSACHUSETTS Section 24.01: Purpose 24.02: Scope 24.03: Definitions 24.04: Approval of Design 24.05: Power Supply
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Strobe Light User s Guide
Strobe Light For models: SL 177i and SL 177 Strobe Light User s Guide ATTENTION! The model SL177 and SL177i strobe lights are designed to notify hearing impaired individuals of impending danger, they have
Smoke Alarm. Owner s Manual. Model CFS10. Combination Alarm
Smoke Alarm Model CFS10 Owner s Manual Combination Alarm Photoelectric Smoke Sensing Rate of Rise Temperature Sensing Fixed Temperature Sensing Proprietary Wireless Connectivity SIGNALING MADE IN THE U.S.A.
Security System 8000. Owner s Manual
Security System 8000 Owner s Manual Contents Introduction... Safety Procedures... Safety Planning... Fire Protection... System Operation... Sensors... Wireless System Keypad (Wireless Remote Transmitter)...
Smoke Alarm User s Guide
P3010H Photoelectric Smoke Alarm w/ Safety Light P3010B Photoelectric Smoke Alarm w/ Voice Alarm P3010L Photoelectric Smoke Alarm Smoke Alarm User s Guide Thank you for purchasing this Kidde Smoke Alarm.
OHIO BOARD OF BUILDING STANDARDS. Smoke Alarms and Fire Safety
OHIO BOARD OF BUILDING STANDARDS Smoke Alarms and Fire Safety Updated January 2016 2 UNDERSTANDING THE TERMINOLOGY Detector. An initiation device suitable for connection to a circuit that has a sensor
MODEL MI106S. UNIVERSAL SMOKE SENSING TECHNOLOGY 2-in-1 SMOKE & FIRE ALARM WITH 10 YEAR TAMPER PROOF PERMANENT POWER SEALED BATTERY BACKUP
Conforms to UL Std. 217 MODEL MI106S Single/ Multiple Station Smoke Alarm UNIVERSAL SMOKE SENSING TECHNOLOGY 2-in-1 SMOKE & FIRE ALARM WITH 10 YEAR TAMPER PROOF PERMANENT POWER SEALED BATTERY BACKUP THANK
Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings
Features SMART SWITCH OCCUPANCY SENSOR Installation Manual Maximum Energy savings Sensitive 180º view passive infrared motion detector keeps lights on only when rooms are in use. No ON switch so lights
Kidde Safety Europe, Mathisen Way, Colnbrook, SL3 0HB, UK. www.kiddefyrnetics.co.uk. Kidde Fyrnetics 2003 SAVE THIS MANUAL FOR FUTURE REFERENCE
Smoke and Heat alarm Owner s Manual 230V Interconnectable Mains Operated Alarms For models: 123I, 123/9HI, 123/9HILL, 223I, 223/9I, 223/9ILL, 223/9HI, 223/9HILL, 323/9HI, 323/9HILL Your home is protected
MODEL USI-7795 SMOKE & CARBON MONOXIDE ALARM WITH SILENCE CONTROL
MODEL USI-7795 SMOKE & CARBON MONOXIDE ALARM WITH SILENCE CONTROL READ ALL INSTRUCTIONS The smoke alarm uses an extremely small amount of a radioactive element in the ionization chamber. Do not tamper
USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model # 900172
Model # 900172: Page 1 USER MANUAL Bottom Loading Bottled Water Dispenser Model # 900172 TO REDUCE THE RISK OF INJURY AND PROPERTY DAMAGE, USER MUST READ THIS MANUAL BEFORE ASSEMBLING, INSTALLING & OPERATING
616, 626, 636 & 646 Keypads
616, 626, 636 & 646 Keypads User s Manual TABLE OF CONTENTS 1.0 BASIC OPERATION...2 2.0 ACCESS CODES...4 3.0 ARMING & DISARMING...6 4.0 PANIC ZONES...13 5.0 KEY ACCESS PROGRAMMING.14 6.0 ADDITIONAL FEATURES...15
Installation and Operation Guide for PD4100 Series Power Control Centers
Installation and Operation Guide for PD4100 Series Power Control Centers Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as
Installation and Operation Guide for PD5100 Automatic Transfer Switch
Installation and Operation Guide for PD5100 Automatic Transfer Switch Member P r o gr e ssive Dynamics, Inc. 507 Industrial Rd Marshall, MI 49068 www.progressivedyn.com 2012 Progressive Dynamics, Inc.
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL Service Information If service or parts are required, contact the nearest Norcold Service Center. To find an authorized Norcold Service Center
3 WATT LED SPOTLIGHT Model No. SLM - 3801
3 WATT LED SPOTLIGHT Model No. SLM - 3801 OWNER'S MANUAL Customer Service Tel: 1-800-268-3319 Superex Canada Ltd, Toronto,M2H 3B8 Made in China Table of Contents A). Important Safety Instructions B). Charging
WIRELESS SENSOR BATTERY REPLACEMENT INSTRUCTIONS For Safewatch Residential and Small Business Control Panels
www.adt.com WIRELESS SENSOR For Safewatch Residential and Small Business Control Panels Your ADT Safewatch QuickConnect, SafeWatch 3000 or Vista Series residential or small business security system may
User s Guide. Security Systems D220
User s Guide Security Systems D220 Table of Contents About This User s Guide... 3 Introduction... 3 Security System Basics... 4 Controlled Points... 5 24-Hour Points... 6 Keypad Keys... 6 Keypad Lights...
Installation and Operation Guide for PD4000 Series Power Control Center
Extended warranties are available for purchase at www.progressivedyn.com Installation and Operation Guide for PD4000 Series Power Control Center Member Thank you for selecting Progressive Dynamics as your
WIRELESS SENSOR BATTERY REPLACEMENT INSTRUCTIONS For Safewatch Residential Control Panels
www.adt.ca WIRELESS SENSOR For Safewatch Residential Control Panels Your ADT Safewatch QuickConnect, SafeWatch 3000 or Vista Series residential security system may be installed with wireless sensors, such
User Guide for the DS7060 Control/Communicator
DS7060 User Guide Copyright 1996-97 Detection Systems, Inc. User Guide for the DS7060 Control/Communicator Copyright 1996-97 Detection Systems, Inc. Detection Systems, Inc., 130 Perinton Parkway, Fairport,
Bottom Loading Water Dispenser
Bottom Loading Water Dispenser Model # 601000 TO REDUCE THE RISK OF INJURY AND PROPERTY DAMAGE, USER MUST READ THIS MANUAL BEFORE ASSEMBLING, INSTALLING & OPERATING DISPENSER. SAVE THIS MANUAL FOR FUTURE
TABLE OF CONTENTS HOW TO AVOID FALSE ALARMS... 1
TABLE OF CONTENTS HOW TO AVOID FALSE ALARMS... 1 THE BRINK S HOME SECURITY SYSTEM Equipment in the Standard Systems... 2 Optional Equipment... 3 Description of the Keypad... 5 OPERATING THE BRINK S SYSTEM
Instructions & Safety Information Models A220-20D and A220-20L Version 2
Quick 220 Voltage Converting Power Supply Instructions & Safety Information Models A220-20D and A220-20L Version 2 Quick 220 Systems LLC PO Box 47489 Phoenix, Arizona 85068-7489 800-347-0394 602-938-6057
PHOTOELECTRIC TYPE SINGLE STATION/MULTI-STATION SMOKE ALARMS/AC POWERED WITH BATTERY BACK-UP, 120VAC/9VDC, 60Hz OR 220VAC/9VDC, 50/60Hz
9000 SERIES PHOTOELECTRIC TYPE SINGLE STATION/MULTI-STATION SMOKE S/AC POWERED WITH BATTERY BACK-UP, 120VAC/9VDC, 60Hz OR 220VAC/9VDC, 50/60Hz Installation Instructions - Owner's Information READ CAREFULLY
Cambridge Electric Infared Fireplace User Manual
EL1239 WW12993 Cambridge Electric Infared Fireplace User Manual SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. If you are assembling this unit for someone else, give this manual to him or her to read and
IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.
THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to
WARNING To reduce the risk of. READ ALL INSTRUCTIONS BEFORE USING. KEEP AWAY FROM WATER DANGER Any appliance is
IMPORTANT SAFETY INSTRUCTIONS When using electrical appliances, especially when children are present, basic safety precautions should always be followed, including the following: READ ALL INSTRUCTIONS
WTSL-SN-1 Alarm Control Unit with Wi-Safe 2 Installation and User Guide
WTSL-SN-1 Alarm Control Unit with Wi-Safe 2 Installation and User Guide "sona control unit install" For use with Wi-Safe 2 Smoke, Heat and Carbon Monoxide Alarms 1 PLEASE READ THIS GUIDE IN FULL BEFORE
Kidde Safety Europe, Mathisen Way, Colnbrook, SL3 0HB, UK. www.kiddefyrnetics.co.uk. Kidde Fyrnetics 2000 SAVE THIS MANUAL FOR FUTURE REFERENCE
Battery Smoke alarm Owner s Manual 9V Interconnectable Alarms For models: 19HI, 19HILL, 29I, 29ILL, 29HI, 29HILL, Thank you for choosing a Kidde Fyrnetics alarm. Please read through our guide in full.
User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.
User s Guide Oreck Air Purifier with HEPA Filtration Important! Read this manual carefully, and keep for future reference. Enjoy Congratulations on your purchase of the Oreck Air Purifier with HEPA Filtration.
ROTOR LOADER OWNER S MANUAL
ROTOR LOADER OWNER S MANUAL ROTOR LOADER OWNER S MANUAL WARNING IMPORTANT SAFETY INSTRUCTIONS AND GUIDELINES. Misuse of paintball equipment may cause serious injury or death. QUICK SET-UP GUIDE BATTERY
Wine Cooler with Thermo-Electric Cooling & Heating Technology
Wine Cooler with Thermo-Electric Cooling & Heating Technology Model number: WC-0888H (8-bottles capacity) Instruction Manual Please read carefully and follow all safety rules and operating instructions.
Automatic Phone-Out Home Monitoring Systems
Automatic Phone-Out Home Monitoring Systems Power Outage and Freeze Alarm Model Number: THP202 Power Outage, Freeze and Flood Alarm Product Description Model Number: THP201 These monitoring systems are
RHODE ISLAND DIVISION OF STATE FIRE MARSHAL
RHODE ISLAND DIVISION OF STATE FIRE MARSHAL Smoke Alarm and Carbon Monoxide Brochure JOHN E. CHARTIER STATE FIRE MARSHAL 118 PARADE STREET PROVIDENCE, RI 02909 DAYS 401-462-4200 24 Hr. 401-222-2331 FAX#
INSTALLATION GUIDE. Green LED detector is removed from the mounting base. Built-in sounder and mechanical test button.
INSTALLATION GUIDE 1164 Wireless Synchronized Smoke Detector Description The Model 1164 Wireless Synchronized Smoke Detector with Sounder is a 3 volt battery powered, wireless, low profile, photoelectric
Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location
Wireless Alarm System Panic Button User s Manual Choice ALERT Control all sensors, accessories and remote transmitters from one location Table of Contents Important Safeguards 4 Introduction 5 Activating
Your Ademco. Fir&Burglar Alarm System. LogiCenter INTRODUCTION: 1. _- ALARM DEVICE MANUFACTURING CO.
Your Ademco LogiCenter Fir&Burglar Alarm System i INTRODUCTION: Your LogiCenter is designed to alert you in the event of either a forced entry into a protected area or signal an alarm if a fire alarm condition
MUNICIPALITY OF KAZABAZUA. SMOKE DETECTORS By-Law number 07-2012
MUNICIPALITY OF KAZABAZUA SMOKE DETECTORS By-Law number 07-2012 Notice of motion : August 7, 2012 Publication : September 9, 2012 Adoption : November 15, 2012 Effective November 15, 2012 Resolution: 2012-09-234
Fire Facts Smoke Alarms
Fire Facts Smoke Alarms Your chances of dying in a home fire may be reduced by 50 per cent if a working smoke alarm is present in your home. Smoke alarms, when properly installed, tested and maintained,
Wireless Indoor/ Outdoor Thermometer
Wireless Indoor/ Outdoor Thermometer Owner s Manual Please read before using this equipment. ˆ Contents FCC Information... 3 FCC Declaration of Conformity... 5 Preparation... 5 Installing Batteries...
Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL
Electric Kettle Model: SK-1717 INSTRUCTIONS MANUAL Thank you for your purchase. Please read this Instruction Manual thoroughly before use and keep in a safe place for future reference. READ ALL INSTRUCTIONS
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
TABLE OF CONTENTS HOW TO AVOID FALSE ALARMS... 2
TABLE OF CONTENTS HOW TO AVOID FALSE ALARMS... 2 THE BRINK S HOME SECURITY SYSTEM Equipment in the Standard Systems... 3 Optional Equipment... 4 Optional Features... 5 Description of the Keypad... 6 OPERATING
Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps
Model Name Total Output Amps Per Bank Battery System Pro XL Dual Pro XL Pro SE Dual Pro SE Three Bank Pro SE Four Bank Pro SE Pro Charger Dual Pro Charger Three Bank Pro Charger 6 amps 12 amps 10 amps
Doorbell Intercom Security System
Doorbell Intercom Security System POWER IN USE OFF A B C LOCK CALL TALK Installation Guide Model WHDB-301 EXPLANATION OF GRAPHIC WARNING SYMBOLS This symbol is intended to alert the user to the presence
Consumer Product Safety Commission Smoke Alarms Why, Where, and Which CPSC Pub. 559
Consumer Product Safety Commission Smoke Alarms Why, Where, and Which CPSC Pub. 559 A smoke alarm is critical for the early detection of a fire in your home and could mean the difference between life and
2-SLICE COOL TOUCH TOASTER
2-SLICE COOL TOUCH TOASTER PLA0405 Instruction Manual Due to on-going product improvements, specifications and accessories may change without notice. Actual product may differ slightly to that depicted.
INSTALLER INSTRUCTIONS
230V~ SMOKE & HEAT ALARMS ALKALINE BATTERY BACK-UP Ei141RC - Ionisation Ei144RC - Heat Ei146RC - Optical RECHARGEABLE LITHIUM CELL BACK-UP Ei161RC - Ionisation Ei164RC - Heat Ei166RC - Optical INSTALLER
ESL 500 Series. Smoke Detector. Installation Instructions
ON 1 2 Smoke Installation Instructions Description The Smoke s offer 2-wire, 4-wire, 12VDC, and 24VDC detectors for fire system applications. Depending on the model, the smoke detector provides the following
LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS
OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS LiteAide HE-100B HE-100BW HE-112 HE-112W HE-117 HE-117W HE-117-2B OWNER'S MANUAL FLOOD LAMPS (BULBS) Your
Installation and Operating Instructions (for chargers shown below)
Installation and Operating Instructions (for chargers shown below) For additional information please call our Technical Support Group 800.742.2740 PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard,
USER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS
St. Louis County Department of Public Works Division of Code Enforcement KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS This guideline is intended to provide the homeowner/contractor with the
OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER
OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER P110 Your battery charger has been engineered and manufactured to Ryobi s high standard for dependability, ease of operation, and operator safety. When properly
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
Single Station Remote Alarm
ADI 5106G Certified ISO 9001:2000 Single Station Remote Alarm 529 5106-01-120 529 5106-01-220 INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Controls Corporation
User Guide for the Kidde RemoteLync. Remote Notification Device
User Guide for the Kidde RemoteLync Remote Notification Device 120V AC 3 Color LED Indicator Voice Message System For questions concerning your device, please call our Product Support Line at 1-800-880-6788.
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
cairn HMO Tenant Information Property Address: Letting: 0141 270 7878 Maintenance: 0141 270 7856
cairn HMO Tenant Information Property Address: Letting: 0141 270 7878 Maintenance: 0141 270 7856 1 1. Use of communal areas In most properties you share the common stair and door entry systems with your