MODEL MI3050S. UNIVERSAL SMOKE SENSING TECHNOLOGY 2-in-1 SMOKE & FIRE ALARM WITH 10 YEAR PERMANENT POWER SEALED BATTERY
|
|
|
- Caitlin Hart
- 10 years ago
- Views:
Transcription
1 Conforms to UL Std. 217 MODEL MI3050S Single Station Smoke Alarm UNIVERSAL SMOKE SENSING TECHNOLOGY 2-in-1 SMOKE & FIRE ALARM WITH 10 YEAR PERMANENT POWER SEALED BATTERY READ ALL INSTRUCTIONS THANK YOU for purchasing this smoke and fire alarm. This alarm does not require battery changes. The tamper proof permanent power sealed battery which will last for approximately 10 years. This manual includes important information regarding where to install the alarm, how to operate, maintenance, testing and product features. It also includes tips and information which can help protect you and your family. Table of Contents: Page # Smoke Alarm Limitations and Functions... 2 Recommended Location of Alarms... 3 Avoid These Locations... 4 Early Warning... 4 How to Install... 4 Locking/AlarmTamper Feature... 4 Operation, Testing & Maintenance... 5 QUICK FIND Alarm Originating Feature & Reset... 5 Silence Feature... 6 Cautions/Warnings... 6 Battery and Alarm Deactivation... 6 Develop and Practice a Plan of Escape... 7 Quick Reference Guide / Operational Summary... 8 Warranty...Back Cover READ ALL INSTRUCTIONS This smoke alarm uses an extremely small amount of a radioactive element in the ionization chamber. Do not tamper with radioactive sealed source or try to repair the smoke alarm yourself.
2 SMOKE ALARM LIMITATIONS AND FUNCTIONS There are three basic smoke alarm types: Universal Smoke Sensing Technology, Ionization and Photoelectric. Universal Smoke Sensing Technology is an ionization alarm containing patented Smart Alarm Technology. Alarms containing Universal Smoke Sensing Technology are effective at detecting fast flaming fires and slow smoldering fires. Ionization smoke alarms are typically more effective at detecting fast flaming fires fires which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a wastebasket, or kitchen grease fires. Photoelectric smoke alarms, on the other hand, are typically more effective at detecting slow smoldering fires fires which burn for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. Installing alarms containing Universal Smoke Sensing Technology ensures maximum detection of both types of fires from a single alarm. The enclosed alarm is a 2-in-1 Universal Smoke Sensing Technology Smoke and Fire Smart Alarm. SMOKE ALARMS WILL NOT WORK DURING A LOSS OF POWER. SINCE A SMOKE ALARM WILL NOT WORK WITHOUT POWER, having an alarm(s) that works from two completely different power sources, such as an AC direct wire with battery backup smoke alarm, can give you an extra measure of protection in case of an AC power failure or a dead battery. Battery operated alarms cannot work if the batteries are missing, disconnected or dead. AC (only) powered alarms cannot work if the AC power is cut off for any reason. If you are concerned about the limitations of the battery or AC power, install both types of alarms. USING AN IONIZATION SMOKE ALARM IN A SMOKY AREA, SUCH AS A KITCHEN, OR IN A HIGH HUMIDITY AREA NEAR A SHOWER, CAN CAUSE NUISANCE FALSE ALARMS. IT IS PREFERABLE TO USE PHOTOELECTRIC ALARMS IN THESE AREAS. DO NOT TURN OFF THE AC POWER TO QUIET THE ALARM. A SMOKE ALARM WILL NOT HELP PROTECT YOU IF IT IS NOT POWERED. Properly locate your alarm to avoid nuisance alarms. A SMOKE ALARM MAY NOT ALWAYS WARN YOU ABOUT FIRES CAUSED BY CARELESSNESS AND SAFETY HAZARDS LIKE SMOKING IN BED, VIOLENT EXPLOSIONS, ESCAPING GAS, IMPROPER STORAGE OF FLAMMABLE MATERIALS, OVERLOADED ELECTRICAL CIRCUITS, CHILDREN PLAYING WITH MATCHES, NATURAL CAUSES SUCH AS LIGHTNING, OR ARSON. FIRE PREVENTION IS YOUR BEST SAFEGUARD. INSTALLING SMOKE ALARMS MAY MAKE YOU ELIGIBLE FOR LOWER INSURANCE RATES, BUT SMOKE ALARMS ARE NOT A SUBSTITUTE FOR INSURANCE. Homeowners and renters alike should continue to insure their lives and properties. SMOKE ALARMS CANNOT DETECT FIRES IF THE SMOKE DOES NOT REACH THEM. Smoke from fires may not reach the sensing chamber and set off the alarm. One alarm should be installed inside each bedroom or sleeping area. Do not obstruct airflow around the smoke alarm or place in areas of obstructed airflow. BE AWARE OF VARIOUS SITUATIONS AGAINST WHICH THE SMOKE ALARM MAY NOT BE EFFECTIVE. For example: (1) Fires where the victim is intimate with a flaming initiated fire; for example, when a person's clothes catch fire while cooking; (2) Fires where the smoke is prevented from reaching the alarm due to a closed door or other obstruction or (3) Incendiary fires where the fire grows so rapidly that an occupant's egress is blocked even with properly located alarms. SMOKE ALARMS MAY NOT DETECT FIRE ON ANOTHER FLOOR OR AREA OF THE HOME. Recommended minimum protection is at least one smoke alarm in every sleeping area and every bedroom on every level of your home. Interconnected smoke alarms may provide earlier warning than stand-alone smoke alarms since all smoke alarms alarm when one detects smoke. SMOKE ALARMS MAY NOT BE HEARD. The alarm horn in this alarm meets or exceeds current standards, but it may not be heard if: (1) the smoke alarm is located outside a closed or partially closed door; (2) residents recently consumed alcohol or drugs; (3) the alarm is drowned out by noise from stereos, TV's, air conditioners or other appliances; (4) residents are hearing impaired or (5) if residents are sleeping. CURRENT STUDIES HAVE SHOWN SMOKE ALARMS MAY NOT AWAKEN ALL SLEEPING INDIVIDUALS AND THAT IT IS THE RESPONSIBILITY OF INDIVIDUALS IN THE HOUSEHOLD WHO ARE CAPABLE OF ASSISTING OTHERS TO PROVIDE ASSISTANCE TO THOSE WHO MAY NOT BE AWAKENED BY THE ALARM SOUND OR TO THOSE WHO MAY BE INCAPABLE OF SAFELY EVACUATING THE AREA UNASSISTED. SMOKE ALARMS ARE NOT FOOLPROOF. You must test the smoke alarm weekly to ensure your continued protection. Smoke alarms cannot prevent or extinguish fires. SMOKE ALARMS HAVE A LIMITED LIFE. The smoke alarm should be replaced immediately if it is not operating properly. You should always replace a smoke alarm after 10 years. SMOKE ALARMS ARE NOT TO BE USED WITH DETECTOR GUARDS UNLESS THE COMBINATION HAS BEEN EVALUATED AND FOUND SUITABLE FOR THAT PURPOSE. RECOMMENDED LOCATION OF ALARMS Locate the first smoke alarm in the immediate area of the bedrooms. Try to protect the escape route as the bedrooms are usually farthest from an exit. If more than one sleeping area exists, locate additional smoke alarms in each sleeping area. If a hall is more than 40 feet (12 meters) long, install a smoke alarm at each end. Locate additional smoke alarms to protect any stairway as stairways act like chimneys for smoke and heat. Page 2
3 RECOMMENDED LOCATION OF ALARMS Locate the first smoke alarm in the immediate area of the bedrooms. Try to protect the escape route as the bedrooms are usually farthest from an exit. If more than one sleeping area exists, locate additional smoke alarms in each sleeping area. If a hall is more than 40 feet (12 meters) long, install a smoke alarm at each end. Locate additional smoke alarms to protect any stairway as stairways act like chimneys for smoke and heat. Locate at least one smoke alarm on every floor level. Locate a smoke alarm in any area where a smoker sleeps or where electrical appliances are operated in sleeping areas. Smoke, heat and other combustion products rise to the ceiling and spread horizontally. Mounting the smoke alarm on the ceiling in the center of the room places it closest to all points in the room. Ceiling mounting is preferred in ordinary residential construction. However, in mobile homes, wall mounting on an inside partition is preferred to avoid the thermal barrier that may form at the ceiling. When mounting smoke alarm on the ceiling, locate it a minimum of 4" (10cm) from a side wall or corner (see Diagram A). When mounting smoke alarm on a wall, if local codes allow, use an inside wall with the top edge of the smoke alarm a minimum of 4" (10cm) and a maximum of 12" (30.5cm) below the ceiling/wall intersections (See Diagram A). Existing Homes: The NFPA requires a smoke alarm on every level and outside each sleeping area in existing construction. An existing household with one level and one sleeping area is required to have one smoke alarm. New Construction Homes and Manufactured Homes: The NFPA requires AC-powered, interconnected smoke alarms to be installed inside each bedroom, outside each bedroom area, and on every level of the home. They also require a minimum of two AC-powered, interconnected smoke alarms in any new construction home. Sloped Ceilings (Peaked Ceilings): Smoke alarms or smoke detectors mounted on a peaked ceiling shall be located within 36 in. (914 mm) horizontally of the peak, but not closer than 4 in. (102 mm) vertically to the peak. Sloped Ceilings (Shed Ceilings): Smoke alarms or smoke detectors mounted on a sloped ceiling having a rise greater than 1 ft. in 8 ft. (1 m in 8 m) horizontally shall be located within 36 in. (914 mm) of the high side of the ceiling, but not closer than 4 in. (102 mm) from the adjoining wall surface. Tray-Shaped Ceilings: Smoke Alarms or smoke detectors shall be installed on the highest portion of the ceiling or on the sloped portion of the ceiling within 12 in. (305 mm) vertically down from the highest point. Mobile Home Installation: For minimum protection, smoke alarms should be installed in compliance with H.U.D. Manufactured Home Construction Safety Standards, Title 24 CFR, Section and Section For additional protection, see Single Story Residence smoke alarm requirements/recommendations for Existing Homes and New Construction Homes. Note: For mobile homes built before 1978, install smoke alarms on inside walls between 4 and 12 from the ceiling (older mobile homes have little or no insulation in the ceiling). This is especially important if the ceiling is unusually hot or cold. Install a smoke alarm inside each bedroom and in the hallway outside each separate sleeping area. Page 3
4 AVOID THESE LOCATIONS the garage products of combustion are produced when you start your vehicle. near appliances or areas where normal combustion regularly occurs (kitchens, near furnaces, gas hot water heaters). Use smoke alarms with U.S.S.T. or photoelectric sensors, or smoke alarms with Silence Feature for these areas. in areas with high humidity, like bathrooms or areas near dishwashers or washing machines. Install at least 3 feet (0.9 meters) away from these areas. in areas of turbulent air such as air returns or heating and cooling supply vents, smoke alarms shall not be located where airflow prevents smoke from reaching the alarms. in extremely dusty, dirty or insect-infested areas. Loose particles interfere with smoke alarm operation. in areas where temperature may fall below 40 0 F (4.4 0 C) or rise above F ( C). closer than 1 foot (0.3m) from fluorescent lights, electrical "noise" and flickering may affect the alarm's operation. closer than 3 feet (0.9m) horizontal path from the tip of the blade of a ceiling suspended (paddle) fan. on a poorly insulated ceiling or exterior wall (mount smoke alarm on an inside wall). This alarm will not work until it is activated and properly installed. This alarm should be tested immediately after installation and then tested weekly after that. If the alarm ever fails to test correctly, have it replaced immediately. If the alarm is not working properly, it cannot alert you to a problem. This alarm must have battery power to operate. If the battery is dead, the alarm cannot operate. The sealed battery cannot be replaced. Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows: A smoke alarm installed in each separate sleeping area (in the vicinity of, but outside of, the bedrooms); and, as appropriate, heat or smoke alarms in living rooms, dining rooms, kitchens, hallways, attics, furnace rooms, closets, utility storage rooms, basements and attached garages. Test the alarms weekly to assure proper operation. HOW TO INSTALL IMPORTANT: Read all instructions before using this product. CAUTION: This smoke alarm is sealed. The cover is not removable. 1. A mounting bracket is provided on the back of the alarm. Remove the mounting bracket from the back of the alarm by holding the mounting bracket and twisting the alarm in the direction indicated by the TWIST TO REMOVE arrow on the side of the alarm base. 2. Attach the mounting bracket in the proper location on the wall or ceiling (screws and anchors provided. 3. Activate the Permanent Power battery feature by removing and discarding the battery pull tab. The alarm will sound one long beep to confirm it is powered up. Once activated, the alarm cannot be turned off without permanent deactivation. The alarm will remain on for the next ten years (under normal operating conditions). 4. Press the Test/Silence button. The alarm will sound 3 beeps, 2 second pause, 3 beeps and the red power LED will blink in sync with the cycle of 3 beeps and turn off. 5. Push and twist the alarm clockwise onto the mounting bracket. 6. The red LED will blink on approx. every 2 minutes to indicate proper operation. 7. Refer to Locking/Tamper feature to utilize the optional alarm tamper resistant feature. Failure to properly install and activate this alarm will prevent proper operation of this alarm and will prevent its response to fire hazards. Test the alarm following installation and weekly thereafter. The built-in test switch accurately tests the alarm operation as required by ANSI/UL217 Standards for Safety. If, at any time, you test the alarm and it does not perform as described, replace it immediately. CAUTION: Due to the loudness of the alarm, we suggest that you place your fingers over the sounder opening while testing your alarm. Continuous exposure to the high sound level of this alarm over an extended period of time may cause hearing loss. OPTIONAL ALARM TAMPER RESISTANT FEATURE: The tamper resistant locking feature for this model deters someone from removing the alarm from the mounting bracket. The breakaway locking pin is clearly marked and molded into the mounting bracket. Refer to Figure 1. TO ACTIVATE THE ALARM LOCKING FEATURE: Do not activate the locking feature until you have activated the battery, mounted the smoke alarm to the bracket and tested the smoke alarm. Refer to OPERATION, TESTING & MAINTENANCE instructions on Page 5. Page 4
5 1. Detach the breakaway alarm locking pin from the mounting bracket. 2. Insert the pin into the hole in the side of the alarm after the alarm has been installed on the mounting plate. Refer to the diagram below for correct placement. INSERT ALARM LOCKING PIN HERE (optional) FIGURE 1 TO DEACTIVATE THE LOCKING FEATURES: To remove the smoke alarm for cleaning or servicing, you must first remove the locking pin, if it has been installed. 1. Use long nose pliers to pull the locking pin out of the hole. 2. It is now possible to remove the smoke alarm. OPERATION, TESTING & MAINTENANCE OPERATION: The smoke alarm is operating once the battery power is connected by removing the pull-tab. When products of combustion are sensed, the alarm sounds a loud alarm which continues until the air is cleared. This alarm incorporates the NFPA recognized horn signal for evacuation. During alarm mode, the horn produces three beeps followed by a two second pause and then continually repeats. READY/ACTIVE CONDITION: The red LED blinks on once approx. every 2 minutes to indicate the alarm is properly functioning. ALARM CONDITION: The alarm emits a loud, pulsating alarm sound and the red LED blinks on in sync with horn. NUISANCE ALARMS: The smoke alarm is designed to minimize nuisance alarms. Smoking will not normally set off the alarm unless smoke is blown directly into the smoke alarm. Combustion particles from cooking may set off the alarm if the smoke alarm is located close to the kitchen cooking surface. Large quantities of combustion particles are generated from spills or broiling. If the smoke alarm does sound, check for fires first. If a fire is discovered, get out and call the fire department. If no fire is present, check to see if one of the reasons listed above may have caused the alarm. Use the Silence Feature if it is a nuisance alarm, or reset the alarm by pressing and holding the Test/Silence button for ten seconds. Refer to RESET below. NOTE: It is best to "reset" the alarms before initial test is performed. See below for Reset procedures. TESTING: Test by pressing the Test/Silence button on the smoke alarm cover until the alarm sounds, then release. The alarm sounds if all electronic circuitry, horn and battery are working. If no alarm sounds, the alarm may have a power supply failure. Test the smoke alarm weekly to assure proper operation. IMPORTANT: Under normal conditions, the test button should sound the alarm immediately after it is pressed. There are special conditions that, when you press the Test/Silence button, you will experience a delay of approx seconds before the alarm sounds. This delay occurs if the Test/Silence button is pressed during a self-diagnostic period. This may occur after initial power up. Retest after seconds. ALARM ORIGINATION: The QUICK FIND feature will allow you to immediately locate the originating alarm (once the alarm has stopped sounding). To initiate QUICK FIND, press the Test/Silence button on each alarm. After releasing the button, the originating alarm will continue to sound for 60 seconds. It is necessary to test each alarm to determine the originating alarm. RESET: To reset the QUICK FIND Alarm Origination condition, press and hold the Test/ Silence button on any alarm for at least 10 seconds and then release. This will clear alarm origination indicator. Reset after each alarm activation. END-OF-SERVICE LIFE NOTIFICATION: A majority of home fire deaths are a result of no smoke alarms or no working smoke alarms. In addition to the "replace by date" stamped on the back of your alarm, your alarm contains a unique audible end-of-service life notification feature. When it is time to replace your alarm, which is after approximately 10 years of operation from initial power up, the alarm will sound 2 chirps approx. every 60 seconds and the red LED will blink on once approx. every 2 minutes. The alarm should be replaced immediately. Page 5
6 IMPORTANT CONSIDERATIONS YOUR ALARM HAS BEEN DESIGNED WITH A PRODUCT END-OF-SERVICE LIFE WARNING WHICH WILL SOUND AFTER APPROXIMATELY 10 YEARS OF OPERATION FROM INITIAL POWER UP. NOTE: MANUFACTURER RECOMMENDS REPLACEMENT OF THIS ALARM 10 YEARS AFTER DATE OF INSTALLATION. NOTE: NUMEROUS ALARMS OR PROLONGED ALARMING IS NOT TYPICAL AND WILL CONSUME THE BATTERY CAPACITY, SHORTENING THE LIFE OF THIS PRODUCT. NEVER use an open flame of any kind to test this smoke alarm. You might accidentally damage or set fire to the smoke alarm or to your home. The built-in test switch accurately tests the smoke alarm's operation as required by Underwriters Laboratories Inc. (UL). If you choose to use an aerosol smoke product to test the smoke alarm, be certain to use one that has been Listed to Underwriters Laboratories, Inc. Safety Standards and use it only as directed. Use of non-ul Listed products or improper use of UL Listed products may affect the smoke alarm's sensitivity. NUISANCE ALARM SILENCE FEATURE: This feature is to be used only when a known alarm condition, such as smoke from cooking, activates the smoke alarm. The smoke alarm Silence Feature is activated by pushing and releasing the Test/Silence button on the smoke alarm cover while in alarm condition. The smoke alarm will automatically reduce sensitivity and the red LED will blink on approx. every 10 seconds to indicate the alarm is in the Silence mode. The smoke alarm will gradually regain normal sensitivity and sound the alarm if particles of combustion are still present. The approx. 10 minute Silence feature may be used repeatedly until the air has cleared, by pushing and releasing the Test/Silence button again. Resetting the smoke alarm after a nuisance alarm is recommended. NOTE: If the Test/Silence button is pressed and held during the Silence mode, the smoke alarm will be tested normally. Upon the release of the Test/Silence button, the Silence mode will be restarted. Before using the alarm Silence Feature, identify the source of smoke and be certain that safe conditions exist. REGULAR MAINTENANCE: Test the alarm at least once per week to verify it is operating properly. Clean this alarm at least once a month to remove dust, dirt, insects and debris. Using a soft brush or wand attachment to a vacuum cleaner, vacuum all sides and cover of smoke alarm. Be sure all the vents are free of debris. DO NOT use spray cleaning chemicals or insect sprays directly on or near the alarm. DO NOT paint the alarm. Doing so may permanently damage the alarm and interfere with alarm s ability to sense smoke. The outside can be wiped with a damp cloth. DO NOT use any household cleaning agents, solvents or sprays including compressed gas dusters or any other chemical on or near your alarm. DO NOT disassemble or attempt to clean inside the alarm. This alarm contains no serviceable parts. If the alarm becomes contaminated by excessive dirt or grease, and cannot be cleaned, it should be replaced immediately. Alarms have a limited life and should always be replaced 10 years from the date of purchase. AFTER CLEANING, REINSTALL YOUR ALARM AND TEST YOUR ALARM BY USING THE TEST BUTTON BATTERY AND ALARM DEACTIVATION This alarm uses a sealed battery. The battery should last for approximately 10 years under normal operating conditions. The smoke alarm has a low battery indicator which is 2 chirps approx. every 60 seconds. The red LED blinks on once approx. every 2 minutes. Due to the loud 85 decibel alarm, stand at arm's length away from the alarm or use ear protection when testing. Weekly testing is required to ensure proper operation. Irregular or low volume sound may indicate a defective alarm and it should be returned for service. Follow instructions to prepare alarm for shipment or disposal. Page 6
7 Deactivation of the alarm is permanent. Do not attempt to open the alarm for any reason. Place this alarm into shut-down mode at the end of its useful service life. Once the smoke alarm has entered end-of-service-life mode, it is necessary to deactivate the alarm operation. This will stop the product end-of-service-life warning signal and also discharge the remaining capacity of the battery to render it safe for disposal. 1. Remove the alarm from the mounting bracket by rotating it in the direction shown by the arrows on the rim of the base. 2. The alarm deactivation key is located in the mounting bracket of the alarm. See Figure2. 3. Use a small flat blade tool to remove the deactivation key (breakaway) from the mounting bracket. 4. Push tip of key into the deactivation slot (keyhole) outline on label and insert fully. 5. Turn key clockwise to the off position slowly until you feel the switch actuate and the key stops turning. 6. This will discharge the alarm battery and stop the alarm chirping after approximately one minute. The alarm is now safe for disposal. 7. The deactivation key cannot be removed and the alarm cannot be attached to the bracket. 8. Be sure to install a new alarm. Once this alarm has been deactivated: The alarm cannot be reactivated The alarm cannot be reattached to the bracket The alarm will no longer detect smoke FIGURE 2
8 REPAIRS AND SERVICES This smoke alarms contains less than 1 microcurie (37 kilobecquerel) of Americium 241, a radioactive material. The distribution of these ionization-type smoke alarms is licensed by the U.S. Nuclear Regulatory Commission; the consumer is exempt from any licensing or requirements. If the smoke alarm is defective in any way, do not tamper with the smoke alarm. Return the smoke alarm for servicing. (See warranty for instructions or in-warranty returns.) There will be a service charge for repairing out of warranty smoke alarms. DEVELOP AND PRACTICE A PLAN OF ESCAPE BASICS OF ESCAPE PLAN o Make a floor plan indicating all doors and windows and at least two escape routes from each room. Second story windows may need a rope or chain ladder. o Have a family meeting and discuss your escape plan, showing everyone what to do in case of fire. o Determine a place outside your home where all of you can meet if a fire occurs. o Familiarize everyone with the sound of the smoke alarm and train them to leave your home when they hear the sound. o Identify children's bedrooms with red stickers placed in the upper left corner of the windows. They are available from your local fire department. o Practice a fire drill at least every six months. Practice allows you to test your plan before an emergency. You may not be able to reach your children. It is important they know what to do! WHAT TO DO WHEN THE ALARM SOUNDS o Leave immediately by your plan of escape. Every second counts, so don't waste time getting dressed or picking up valuables. o In leaving, don't open any inside door without first feeling its surface. If hot, or if you see smoke seeping through cracks, don't open that door! Instead, use your alternate exit. If inside door is cool, place your shoulder against it, open it slightly and be ready to slam it shut if heat and smoke rush in. o Stay close to the floor if air is smoky. Breathe shallowly through a cloth, wet if possible. o Once outside, go to your selected meeting place and make sure everyone is there. o Call the fire department from your neighbor's home not from yours! o Don't return to your home until fire officials say that it is all right to do so. CAUTION (AS REQUIRED BY THE CALIFORNIA STATE FIRE MARSHAL) "Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows. A smoke alarm installed in each separate sleeping area (in the vicinity of, but outside of the bedrooms), and heat or smoke detectors in the living rooms, dining rooms, bedrooms, kitchens, hallways, attics, furnace rooms, closets, utility and storage rooms, basements and attached garages. NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED INFORMATION For your information, the National Fire Alarm Code, NFPA 72, reads as follows: " *Required Detection - Where required by applicable laws, codes, or standards for a specific type of occupancy, approved single and multiple-station smoke alarms shall be installed as follows: (1) *In all sleeping rooms and guest rooms (2) *Outside of each separate dwelling unit sleeping area, within 6.4 m (21 ft) of any door to a sleeping room, the distance measured along a path of travel (3) On every level of a dwelling unit, including basements. (4) On every level of a residential board and care occupancy (small facility), including basements and excluding crawl spaces and unfinished attics (5) *In the living area(s) of a guest suite (6) In the living area(s) of a residential board and care occupancy" The equipment should be installed using wiring methods in accordance with the National Fire Protection Association's Standard 72. (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269) Page 7
9 QUICK REFERENCE GUIDE / OPERATIONAL SUMMARY CONDITION New - Out of Package ALARM AUDIBLE & VISUAL SIGNALS HORN RED LED Silent Off RECOMMENDATION To activate the alarm, remove the pull tab. The alarm will sound one long beep to confirm it is powered up. Press the Test/Silence button. Test the alarm following installation and weekly thereafter. The built-in test switch accurately tests the alarm operation as required by ANSI/UL217 Standards for Safety. If, at any time, you test the alarm and it does not perform as described, replace it immediately. DC Power is Present Silent Blinks On once 2 minutes The alarm is operating properly. Test/Silence Button Has Been Pressed 3 beeps, 2 second pause, Repeat Blinks On in sync with Horn The alarm is operating properly. Originating Smoke Alarm 3 Beeps, 2 second pause, Repeat Blinks On in sync with Horn If hazard is identified, please take all precautions if an alarm sounds by calling an Emergency Service and getting out of the home. Nuisance Alarm 3 Beeps, 2 second pause, Repeat Blinks On in sync with Horn If there is no hazard present, verify the alarm is mounted in the correct location (see User's Manual, "AVOID THESE LOCATIONS" section). Reset alarm as instructed below. Alarm has Sensed Smoke Alarm has Previously Sensed Smoke Alarm needs to be reset due to varying conditions/ previous alarms 3 Beeps, 2 second pause, Repeat Silent (alarmed previously) Silent Blinks On in sync with Horn Blinks On once 2 minutes (normal operation mode) or Blinks On once 10 seconds (silence mode) Blinks On once 2 minutes (normal operation mode) or Blinks On once 10 seconds (silence mode) Silence Feature is activated by pressing and releasing the Test/ Silence button on the initiating alarm while in alarm condition. Silence mode will last for approx 10 minutes with the red LED blinking once approx. every 10 seconds. QUICK FIND Alarm Origination - The QUICK FIND feature will allow you to locate the originating alarm (once the alarms have stopped sounding). To initiate QUICK FIND, press the Test/Silence button on any alarm. After releasing the button, the originating alarm will continue to sound for approx 60 seconds. It is necessary to test each alarm to determine the originating alarm. To reset the alarm, hold the Test/Silence button for approx 10 seconds and release. This will clear Alarm Origination. Reset alarm after every alarm event. Low Battery 2 chirps 60 seconds Blinks On once 2 minutes Deactivate alarm (see User's Manual "ALARM DEACTIVATION" section). Replace alarm immediately. Product End-of-Service Life Notification 2 chirps 60 seconds Blinks On once 2 minutes Deactivate alarm (see "ALARM DEACTIVATION" section in User's Manual). Replace alarm immediately. Alarm Reset - Press and Hold the Test/Silence button for approximately 10 seconds and release. This will clear the Silence Feature and Alarm Origination. THIS PRODUCT CONFORMS TO UL STANDARD 217 FOR SAFETY Page 8
10 MODEL MI3050S TEN-YEAR LIMITED WARRANTY USI Electric, Inc. /Universal Security Instruments, Inc. ( USI ) warrants this product to be free from defects in material and workmanship for a period of 10 (ten) years from the date of purchase. This warranty shall not apply to any damage which may be caused by the sealed batteries used in this product. This warranty applies only to the original consumer purchaser and only to products used in normal residential use and service. If this product is found to be defective, USI s only obligation, and your exclusive remedy, is the repair or replacement of the product, at USI s discretion, provided that the product has not been damaged through misuse, abuse, accident, modification, alteration, neglect or mishandling. This Warranty shall not apply to any product which is found to have been improperly installed, set-up, or used in any way not in accordance with the instructions supplied with this product. ALARM RETURNS For replacement of this alarm under the terms of this Warranty, contact the Customer Service Department at extension 238 to obtain the current postage and handling fees. USI does not warrant, and specifically disclaims any warranty, whether express or implied, of fitness for a particular purpose, other than the warranty contained herein. No implied warranty on this product, created by state law, shall extend beyond the term of this warranty unless such law otherwise provides. USI specifically disclaims any liability and shall not be liable for any consequential or incidental loss or damage, including, but not limited to, damages to any equipment with which this product is used. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. No agent, representative, dealer, or employee of the company has the authority to increase or alter the obligations or terms of this Warranty. This Warranty gives you specific legal rights and you may also have other rights which vary from state to state. This Warranty is only valid for merchandise purchased from outlets in the United States and Canada. This warranty expires upon product end-of-service life signal. Visit Us on the Web! Cronhill Drive, Suite A Owings Mills, Maryland USA UNIVERSAL SECURITY INSTRUMENTS, INC., Rev. 07/2015 Printed in China
READ ALL INSTRUCTIONS
Visit Us on the Web! www.smokealarms.com MODEL SS-770/SS-771 SMOKE & FIRE ALARM READ ALL INSTRUCTIONS The smoke alarm has a recommended service life of at least 10 years under normal conditions. The smoke
Visit Us on the Web! www.smokealarms.com MODEL USI-1122L LONG LIFE* LITHIUM POWERCELL SMOKE & FIRE ALARM WITH SILENCE CONTROL
Visit Us on the Web! www.smokealarms.com MODEL USI-1122L LONG LIFE* LITHIUM POWERCELL SMOKE & FIRE ALARM WITH SILENCE CONTROL READ ALL INSTRUCTIONS The smoke alarm has a recommended service life of at
MODEL USI-1203/USI-1204 (Part #USI-1203HA/USI-1204HA) COMMERCIAL RESIDENTIAL (UTHA) SMOKE & FIRE ALARM WITH SILENCE CONTROL
MODEL USI-1203/USI-1204 (Part #USI-1203HA/USI-1204HA) COMMERCIAL RESIDENTIAL (UTHA) SMOKE & FIRE ALARM WITH SILENCE CONTROL READ ALL INSTRUCTIONS The smoke alarm has a recommended service life of at least
MODEL MI106S. UNIVERSAL SMOKE SENSING TECHNOLOGY 2-in-1 SMOKE & FIRE ALARM WITH 10 YEAR TAMPER PROOF PERMANENT POWER SEALED BATTERY BACKUP
Conforms to UL Std. 217 MODEL MI106S Single/ Multiple Station Smoke Alarm UNIVERSAL SMOKE SENSING TECHNOLOGY 2-in-1 SMOKE & FIRE ALARM WITH 10 YEAR TAMPER PROOF PERMANENT POWER SEALED BATTERY BACKUP THANK
Smoke Alarm User s Guide
10Y29 For model: 10Y29 Smoke Alarm User s Guide Lithium (non-replaceable sealed in) Battery-Operated Optical Smoke Alarm with HUSH TM Control to temporarily silence nuisance alarms. Thank you for purchasing
INSTALLATION AND OPERATION MANUAL
Photoelectronic Smoke Detector with Built-in Wireless Transmitter INSTALLATION AND OPERATION MANUAL 1 Model # 1008-4 What smoke detectors can do: Smoke detectors are designed to provide early warning of
Smoke Alarm User s Manual
V-MUL-007-A(A0) Smoke Alarm User s Manual Please read and save this manual PHOTOELECTRIC SMOKE ALARM MODEL: VST-S598I Class II Apparatus Photoelectric smoke alarms are generally more effective at detecting
Ionisation Smoke Alarm
0945-7204-00.qxd:_ 2009.7.31 4:25 PM Page Ionisation Smoke Alarm Manual Model Q945 Ionisation smoke alarms are designed to detect invisible particles (associated with fast flaming fires). Home fires develop
Wireless Smoke Alarm User s Guide
RF-SM-DC For model: RF-SM-DC Wireless Smoke Alarm User s Guide Battery powered, wireless Smoke Alarm with SMART HUSH Control to temporarily silence nuisance alarms. Thank you for purchasing a Kidde Wireless
Smoke Alarm User s Guide
SIGNALING U L LISTED Smoke Alarm User s Guide i4618a, i4718a, i5000a Series Model: i4618a 120 Volt Smoke Alarm with 9 Volt Battery Back-up Front Load Battery Test and Hush Button ATTENTION: Please take
SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective
SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective The National Fire Alarm Code, NFPA 72, sets the minimum requirements of performance, selection, use and location of automatic detection
2-WAY WIRELESS SUPERVISED PHOTOELECTRIC SMOKE DETECTOR. Model: EL-4703 INSTALLATION INSTRUCTIONS
2-WAY WIRELESS SUPERVISED PHOTOELECTRIC SMOKE DETECTOR Model: EL-4703 INSTALLATION INSTRUCTIONS GENERAL DESCRIPTION Electronics Line's smoke detector is single station, photoelectric smoke detector with
Smoke Alarm User s Guide
SIGNALING U L LISTED Smoke Alarm User s Guide Model: i9030, i9040, i9040rv i9050, i9060, i9060rv and i9080 i9030 i9040 and i9040rv i9050 i9060 and i9060rv i9080 9 Volt Battery Operated ATTENTION: Please
Smoke Alarm User s Guide
P3010H Photoelectric Smoke Alarm w/ Safety Light P3010B Photoelectric Smoke Alarm w/ Voice Alarm P3010L Photoelectric Smoke Alarm Smoke Alarm User s Guide Thank you for purchasing this Kidde Smoke Alarm.
USER S MANUAL TABLE OF CONTENTS INTRODUCTION. SMOKE ALARM WITH TEN-YEAR NON-REPLACEABLE LITHIUM POWERCELL Model SA340
USER S MANUAL SMOKE ALARM WITH TEN-YEAR NON-REPLACEABLE LITHIUM POWERCELL Model SA340 IMPORTANT! PLEASE READ CAREFULLY AND SAVE. This user s manual contains important information about your Smoke Alarm
User s Manual General Use Smoke Alarm Cat. SA67C, SA67B
INSIDE THIS MANUAL User s Manual General Use Smoke Alarm Cat. SA67C, SA67B Ionization smoke alarms are generally more effective at detecting flaming fires which consume combustible materials rapidly and
MODEL USI-7795 SMOKE & CARBON MONOXIDE ALARM WITH SILENCE CONTROL
MODEL USI-7795 SMOKE & CARBON MONOXIDE ALARM WITH SILENCE CONTROL READ ALL INSTRUCTIONS The smoke alarm uses an extremely small amount of a radioactive element in the ionization chamber. Do not tamper
www.ealarm.com.my P/N 5-051-371-00 Rev D
System 236 System 236i P/N 5-051-371-00 Rev D Thank you for purchasing this C&K alarm system Your system is one of the most powerful and advanced alarm systems on the market today, designed to provide
Ionization alarms are best suited for rooms, which contain highly combustible material. These types of material include:
Smoke Detector University Most people are aware of the danger of fire but are unaware of the fatality of smoke. More people die from breathing smoke than by burns. In fact, deaths from smoke inhalation
Smoke Alarm User s Guide
i12020a i12040a i12080a For models: i12020a, i12040a, i12080a Smoke Alarm User s Guide AC Wire-in Single and/or Multiple Station (up to 24 Devices) Ionization Smoke Alarm with HUSH TM Control to temporarily
10 YEAR LIFE SMOKE ALARM
User Manual 10 YEAR LIFE SMOKE ALARM ST-620 Please read me as I could save your life. Please retain this user manual for future reference CONTENTS INTRODUCTION 2 ALARM SMART SILENCE 11 AUTOMATIC POWER
Smoke Alarm. Manual. i12020aca i12040aca PE120CA. For alarm models:
Smoke Alarm Manual For alarm models: i12020aca i12040aca PE120CA Manual P/N 820-1193 Rev C 1235-7219-04 Note: This alarm has a low battery HUSH feature. If the alarm is sounding a low battery warning chirp,
USER S MANUAL SMOKE ALARMS
USER S MANUAL SMOKE ALARMS Battery Powered Photo & Ion Smoke Alarm Model SA30 with Silence All First Alert and BRK Smoke Alarms conform to regulatory requirements, including UL7 and are designed to detect
IMPORTANT! PLEASE READ CAREFULLY AND SAVE.
USER S MANUAL SMOKE ALARM Model SA00 Model SA0 and Model SA05 With Silence Feature IMPORTANT! PLEASE READ CAREFULLY AND SAVE. This user s manual contains important information about your Smoke Alarm s
USER S MANUAL BATTERY POWERED SMOKE ALARM. Model FG225 Model FG250
USER S MANUAL BATTERY POWERED SMOKE ALARM Model FG225 Model FG250 IMPORTANT! PLEASE READ CAREFULLY AND SAVE. This user s manual contains important information about your Smoke Alarm s operation. If you
User s Guide. Security Systems D220
User s Guide Security Systems D220 Table of Contents About This User s Guide... 3 Introduction... 3 Security System Basics... 4 Controlled Points... 5 24-Hour Points... 6 Keypad Keys... 6 Keypad Lights...
Wireless Smoke Alarm User s Guide
RF-SM-ACDC For model: RF-SM-ACDC Wireless Smoke Alarm User s Guide Wireless Smoke Alarm with SMART HUSH Control to temporarily silence nuisance alarms and battery backup. Thank you for purchasing a Kidde
READ AND SAVE THIS USER S GUIDE
RF-SM-ACDC Wireless Smoke Alarm Hardwire with battery back-up SIGNALING U L LISTED Thank you for purchasing a Kidde Wireless AC Powered Smoke Alarm, part of the Kidde Wireless System. It is an important
120V AC Smoke Alarm with 9V Battery Back-up
L OF FIRE V I 2005 Invensys Controls Americas 120V AC Smoke Alarm with 9V Battery Back-up PHOTOELECTRIC MODEL FPAD 110-1074C PLEASE READ AND SAVE THIS MANUAL Installer: Please leave this manual with the
Smoke Alarm 120V AC. Smoke Alarm. Back-up. with 9V Battery IONIZATION MODELS AD, ADC PHOTOELECTRIC MODEL PAD
1999 Maple Chase Company 120V AC Smoke Alarm with 9V Battery Back-up Smoke Alarm IONIZATION MODELS AD, ADC PHOTOELECTRIC MODEL PAD PLEASE READ AND SAVE THIS MANUAL Installer: Please leave this manual with
Fire Facts Smoke Alarms
Fire Facts Smoke Alarms Your chances of dying in a home fire may be reduced by 50 per cent if a working smoke alarm is present in your home. Smoke alarms, when properly installed, tested and maintained,
120V AC Smoke Alarm with 9V Battery. Back-up IONIZATION MODEL ADC
OF FIRE V I 120V AC Smoke Alarm with 9V Battery Back-up IONIZATION MODEL ADC PLEASE READ AND SAVE THIS MANUAL Installer: Please leave this manual with the product. 110-762F L STATE I S T I N G CALIFORNIA
SINGLE-STATION PHOTOELECTRIC SMOKE DETECTOR SD-738/w USER S MANUAL
SINGLE-STATION PHOTOELECTRIC SMOKE DETECTOR SD-738/w USER S MANUAL TABLE OF CONTENTS INTRODUCTION... 1 LOCATIONS TO INSTALL YOUR SMOKE DETECTOR... 1 LOCATIONS NOT TO INSTALL YOUR SMOKE DETECTORS... 2 INSTALLING
DOMESTIC SMOKE ALARMS
SOUTH AUSTRALIAN METROPOLITAN FIRE SERVICE HOME FIRE SAFETY INFORMATION For further advice contact the Community Safety Department South Australian Metropolitan Fire Service on 8204 3611 DOMESTIC SMOKE
OHIO BOARD OF BUILDING STANDARDS. Smoke Alarms and Fire Safety
OHIO BOARD OF BUILDING STANDARDS Smoke Alarms and Fire Safety Updated January 2016 2 UNDERSTANDING THE TERMINOLOGY Detector. An initiation device suitable for connection to a circuit that has a sensor
USER S MANUAL SMOKE ALARMS
US Patent 6,377,182 Printed in Mexico M08-000-000 Q 09/03 USER S MANUAL SMOKE ALARMS AC Powered Photoelectric Smoke Alarm with Battery Back-Up and Silence Feature Model 7010B Input: 120V AC ~, 60Hz, 0.04A
RHODE ISLAND DIVISION OF STATE FIRE MARSHAL
RHODE ISLAND DIVISION OF STATE FIRE MARSHAL Smoke Alarm and Carbon Monoxide Brochure JOHN E. CHARTIER STATE FIRE MARSHAL 118 PARADE STREET PROVIDENCE, RI 02909 DAYS 401-462-4200 24 Hr. 401-222-2331 FAX#
1. Basic Information about your Smoke Alarm. 2. Locating your Smoke Alarm
B14464-R3-100TY-U&C-ENG.qxd 14/3/04 6:50 AM Page 1 1. Basic Information about your Smoke Alarm A Smoke Alarm is an early warning device. Used correctly it can give you and your family valuable extra time
USER INSTRUCTIONS CONTENTS
CONTENTS Full Set [1]...2 Part Set [2]...2 Night Set [3]...3 Unsetting...3 Unsetting after or during an alarm...3 Testing the system [5]...3 Isolating zones [6]...4 Reprogramming codes [8]...4 Chime facility
USER S MANUAL SMOKE ALARMS
USER S MANUAL SMOKE ALARMS AC Powered Photoelectric Smoke Alarm with Battery Back-Up and Silence Feature Model 7010B Input: 120V AC ~, 60Hz, 0.04A AC Powered Photoelectric Smoke Alarm with Silence Feature
1235CA 1275CA PE120CA
Smoke Alarm M a n u a l For alarm models: 1235CA 1275CA PE120CA SINGLE AND/OR MULTIPLE STATION SMOKE ALARM C o n t e n t s Introduction........................ 1 Installation..........................
Building Control. Householder Guidance Leaflet No. 29. Fire detection in dwellings
Building Control Householder Guidance Leaflet No. 29 Fire detection in dwellings This leaflet is one of a series produced by the Hertfordshire Building Control Technical Forum GUIDANCE NOTE FOR HOME OWNERS
WTSL-SN-1 Alarm Control Unit with Wi-Safe 2 Installation and User Guide
WTSL-SN-1 Alarm Control Unit with Wi-Safe 2 Installation and User Guide "sona control unit install" For use with Wi-Safe 2 Smoke, Heat and Carbon Monoxide Alarms 1 PLEASE READ THIS GUIDE IN FULL BEFORE
527 CMR: BOARD OF FIRE PREVENTION REGULATIONS
527 CMR 24.00: FIRE WARNING SYSTEMS INSTALLED IN BUILDINGS WITHIN THE COMMONWEALTH OF MASSACHUSETTS Section 24.01: Purpose 24.02: Scope 24.03: Definitions 24.04: Approval of Design 24.05: Power Supply
USER S MANUAL Smoke Alarms
USER S MANUAL Smoke Alarms AC Powered Ionization Smoke Alarm with Silence and Latching Features Model 90 Input: 0V AC ~, 60 Hz, 0.0A AC Powered Ionization Smoke Alarm with Battery Back-up, Silence and
LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS
OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS LiteAide HE-100B HE-100BW HE-112 HE-112W HE-117 HE-117W HE-117-2B OWNER'S MANUAL FLOOD LAMPS (BULBS) Your
Smoke Alarm. Owner s Manual. Model CFS10. Combination Alarm
Smoke Alarm Model CFS10 Owner s Manual Combination Alarm Photoelectric Smoke Sensing Rate of Rise Temperature Sensing Fixed Temperature Sensing Proprietary Wireless Connectivity SIGNALING MADE IN THE U.S.A.
Kidde Safety Europe, Mathisen Way, Colnbrook, SL3 0HB, UK. www.kiddefyrnetics.co.uk. Kidde Fyrnetics 2000 SAVE THIS MANUAL FOR FUTURE REFERENCE
Battery Smoke alarm Owner s Manual 9V Interconnectable Alarms For models: 19HI, 19HILL, 29I, 29ILL, 29HI, 29HILL, Thank you for choosing a Kidde Fyrnetics alarm. Please read through our guide in full.
720r Addendum: Siting the 720r
720r Addendum: Siting the 720r UK 1 Cooper Security Limited 2013 Every effort has been made to ensure that the contents of this leaflet are correct. However, neither the authors nor Cooper Security Limited
General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission
General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission Local Fire Alarm 064. FIRE ALARM SYSTEMS 01. Scope 02. Definitions 03.
User Guide for the DS7060 Control/Communicator
DS7060 User Guide Copyright 1996-97 Detection Systems, Inc. User Guide for the DS7060 Control/Communicator Copyright 1996-97 Detection Systems, Inc. Detection Systems, Inc., 130 Perinton Parkway, Fairport,
D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors
D7050/D7050TH EN Installation Instructions Multiplex Photoelectric Smoke Detectors D7050/D7050TH Installation Instructions.0 Description Notices These instructions cover the installation of the D7050/D7050TH
527 CMR: BOARD OF FIRE PREVENTION REGULATIONS
527 CMR 31.00: CARBON MONOXIDE ALARMS Section 31.01: Purpose and Scope 31.02: Definitions 31.03: General Installation Provisions 31.04: Specific Installation Provisions 31.05: Carbon Monoxide Protection:
Kidde Safety Europe, Mathisen Way, Colnbrook, SL3 0HB, UK. www.kiddefyrnetics.co.uk. Kidde Fyrnetics 2003 SAVE THIS MANUAL FOR FUTURE REFERENCE
Smoke and Heat alarm Owner s Manual 230V Interconnectable Mains Operated Alarms For models: 123I, 123/9HI, 123/9HILL, 223I, 223/9I, 223/9ILL, 223/9HI, 223/9HILL, 323/9HI, 323/9HILL Your home is protected
The Alberta Fire Code requires all homes in the province to have working smoke alarms.
Your chances of dying in a home fire may be significantly reduced if a working smoke alarm is present in your home. Smoke alarms, when properly installed, tested and maintained, provide an early warning
FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK
FIREPLACE HEATER FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK If you have any questions about the operation of your fireplace heater, please contact Crane Customer Care. Toll Free: 888-599-0992
CERTIFICATE OF COMPLIANCE
CERTIFICATE OF COMPLIANCE (Smoke Detector Inspection) Smoke detectors and carbon monoxide detectors must be in the proper locations and operational. Your house must also be properly numbered in order to
1161/1162 Residential Wireless Detectors
Installation Guide 1161/1162 Residential Wireless Detectors Description The Model 1161 Smoke Detector with Sounder, and 1162 Smoke/Heat Detector with Sounder are residential, photo electric wireless detectors
Consumer Product Safety Commission Smoke Alarms Why, Where, and Which CPSC Pub. 559
Consumer Product Safety Commission Smoke Alarms Why, Where, and Which CPSC Pub. 559 A smoke alarm is critical for the early detection of a fire in your home and could mean the difference between life and
INSTRUCTION MANUAL PC255O
INSTRUCTION MANUAL PC255O Canadian Department of Communications Notice NOTICE: The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment
USER S MANUAL. SMDC-16 Digital Control Communicator and SMPC-32 Personal Control
SMDC-16 USER S MANUAL SMDC-16 Digital Control Communicator and SMPC-32 Personal Control Table of Contents General Descriptions Page Description of Your Alarm System 3 Description of Keypads 3 Keypad Maintenance
Know Your Smoke Alarm
Know Your Smoke Alarm Updated January 29th 2008 Port Angeles Fire Department, Washington Ver. 1.0 Purpose of Smoke Alarms A smoke detector or smoke alarm is a device that detects smoke and issues an alarm
Your Ademco. Fir&Burglar Alarm System. LogiCenter INTRODUCTION: 1. _- ALARM DEVICE MANUFACTURING CO.
Your Ademco LogiCenter Fir&Burglar Alarm System i INTRODUCTION: Your LogiCenter is designed to alert you in the event of either a forced entry into a protected area or signal an alarm if a fire alarm condition
Smoke and Carbon Monoxide Alarm
User s Guide for Model KN-COSM-B Combination Smoke and Carbon Monoxide Alarm Battery Operated 2-LED Display Hush Peak Level Memory For questions concerning your Smoke and Carbon Monoxide Alarm, please
User Guide for the Kidde RemoteLync. Remote Notification Device
User Guide for the Kidde RemoteLync Remote Notification Device 120V AC 3 Color LED Indicator Voice Message System For questions concerning your device, please call our Product Support Line at 1-800-880-6788.
Guide to Massachusetts Smoke & Carbon Monoxide Requirements
Guide to Massachusetts Smoke & Carbon Monoxide Requirements When Selling a One- or Two-Family Residence DEPARTMENT OF FIRE SERVICES Stephen D. Coan State Fire Marshal M.G.L. c 148 s. 26F - The Law Massachusetts
SPECIAL CODES AUXILIARY CODES SYSTEM NOTES
Installing/Service Company Monitoring Center SPECIAL CODES Master Code Duress Code AUXILIARY CODES "Quick Arm" " Chime" 08 02 09 03 10 04 11 05 12 06 13 07 14 SYSTEM NOTES Exit Delay Time Entry Delay Time
616, 626, 636 & 646 Keypads
616, 626, 636 & 646 Keypads User s Manual TABLE OF CONTENTS 1.0 BASIC OPERATION...2 2.0 ACCESS CODES...4 3.0 ARMING & DISARMING...6 4.0 PANIC ZONES...13 5.0 KEY ACCESS PROGRAMMING.14 6.0 ADDITIONAL FEATURES...15
Smoke & Carbon Monoxide
A Guide to the Massachusetts Smoke & Carbon Monoxide Requirements when Selling a Oneor Two-Family Residence FIRE SERVICES Department of Fire Services PO Box 1025 Stow, MA 01775 978-567-3300 www.mass.gov/dfs
SMOKE ALARM MAINTENANCE PROGRAM
SMOKE ALARM MAINTENANCE PROGRAM The intent of this program is for owners who normally do not get in to their rental units on an annual basis to make sure the smoke alarms are properly maintained. By having
Automatic Phone-Out Home Monitoring Systems
Automatic Phone-Out Home Monitoring Systems Power Outage and Freeze Alarm Model Number: THP202 Power Outage, Freeze and Flood Alarm Product Description Model Number: THP201 These monitoring systems are
INSTRUCTION MANUAL LCD-6OO SECURITY STATION
INSTRUCTION MANUAL 1993 Digital Security Controls Ltd. 1645 Flint Road, Downsview, Ontario, Canada M3J 2J6 Printed in Canada 29000144 R1 LCD-6OO SECURITY STATION Table of Contents Introduction 1 About
BUILDING CONTROL GUIDANCE SHEET SMOKE ALARMS IN STANDARD DWELLINGS Last updated 16/12/2010
Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET SMOKE ALARMS IN STANDARD DWELLINGS Last updated 16/12/2010 Page 1 of 7 PURPOSE: This Guidance
SECURITY SYSTEM NOTES SPECIAL CODES AUXILIARY ARM / DISARM CODES ENTRY / EXIT DELAY TIMES ZONE DESCRIPTIONS
SECURITY SYSTEM NOTES Installing/Service Company For Service Call SPECIAL CODES Master Code Duress Code "Quick Arm" Digit "Chime" Digit "Entry-Guard" Digit AUXILIARY ARM / DISARM CODES 02 12 22 03 13 23
Strobe Light User s Guide
Strobe Light For models: SL 177i and SL 177 Strobe Light User s Guide ATTENTION! The model SL177 and SL177i strobe lights are designed to notify hearing impaired individuals of impending danger, they have
Are photoelectric smoke alarms better than ionization smoke alarms for adjacent to kitchen installations, to minimize nuisance alarms?
Are photoelectric smoke alarms better than ionization smoke alarms for adjacent to kitchen installations, to minimize nuisance alarms? Information Report Applied Research Office of the Fire Marshal March
Owner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
Workplace Fire Safety
Teaching Guide Workplace Fire Safety for staff Seattle Fire Department Fire Prevention Division Workplace Fire Safety Instructor Outline Introduction Goals: To ensure that employees are knowledgeable in
St. John s University
St. John s University Fire Safety Plan Founder s Village Townhouses Page 1 St. John s University Fire Safety Plan Part 1-Building Information Section Founder s Village Townhouses 8000 Utopia Parkway Jamaica
User s Guide. Security Systems
User s Guide Security Systems National Security Systems Inc (800)457-1999 2 Table of Contents About This Users Guide... 4 Introduction... 4 Security System Basics... 5 Controlled Points... 6 24-Hour Points...
User s Guide. Security Systems
User s Guide Security Systems 2 Table of Contents About This Users Guide... 4 Introduction... 4 Security System Basics... 5 Controlled Points... 6 24-Hour Points... 7 Keypad Keys... 7 Keypad Tones... 8
READ THIS FIRST CONT.
READ THIS FIRST CONT. ALL INTERCONNECTED ALARMS OPERATE WHEN EACH TEST BUTTON IS PRESSED FOR 10 SECONDS. REMOVE UNIT FROM MOUNTING PLATE BY RELEASING CATCH AS SHOWN IN FIGURE 1, SWITCH OFF MAINS FIRST.
INSTALLER INSTRUCTIONS
230V~ SMOKE & HEAT ALARMS ALKALINE BATTERY BACK-UP Ei141RC - Ionisation Ei144RC - Heat Ei146RC - Optical RECHARGEABLE LITHIUM CELL BACK-UP Ei161RC - Ionisation Ei164RC - Heat Ei166RC - Optical INSTALLER
SMOKE ALARMS CLASS 1A BUILDINGS
SMOKE ALARMS CLASS 1A BUILDINGS A smoke alarm is a device that combines both smoke detection and alarm facilities into a single unit. Smoke alarms are required to be installed in all new residential Class
NetworX NX-6V2. LED Keypad User Manual
NetworX NX-6V2 LED Keypad User Manual POWER Light is on when AC power is present; flashes to indicate a low battery condition. ARMED Light is on when armed; off when disarmed; flashes to indicate a previous
Security System 8000. Owner s Manual
Security System 8000 Owner s Manual Contents Introduction... Safety Procedures... Safety Planning... Fire Protection... System Operation... Sensors... Wireless System Keypad (Wireless Remote Transmitter)...
INSTALLATION GUIDE. Green LED detector is removed from the mounting base. Built-in sounder and mechanical test button.
INSTALLATION GUIDE 1164 Wireless Synchronized Smoke Detector Description The Model 1164 Wireless Synchronized Smoke Detector with Sounder is a 3 volt battery powered, wireless, low profile, photoelectric
SECURITY SYSTEM NOTES SPECIAL CODES. Security System Configuration
Installing / Service Company: SECURITY SYSTEM NOTES For Service Call: Master Code SPECIAL CODES Duress Code Security System Configuration Auxiliary Code(s) Quick Arm" Digit: 2 9 3 10 4 11 5 12 6 13 7 14
120 VAC, 60 Hz, 100 ma Maximum Single Station Carbon Monoxide Alarm Also suitable as a Residential Gas Detector
Models MCN400, MCN400L, MCND401, MCND401L Certified to Standards UL 2034 & UL 1484 Plug-In Carbon Monoxide & Natural Gas Alarm with Backup Battery Protection Models MCN600, MCN600L, MCND601, MCND601L Single
Smoke Alarms Save Lives!
Smoke Alarms Save Lives! Every year in America, almost 3000 people die in home fires. Most of these people die in homes that do not have working smoke alarms in them. Smoke alarms warn you and your family
SECURITY SYSTEM NOTES. Security System Configuration
Installing / Service Company: For Service Call: SECURITY SYSTEM NOTES Security System Configuration Master Code: Auxiliary Code(s) 2 3 4 5 6 "Quick Arm" Digit: Exit Delay Time Auxiliary Exit Delay Time
HILLS Series LED Code Pad User Manual
HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2
S.A.F.E. FAMILY SMOKE ALARM FOR EVERY FAMILY INSTALLATION PROGRAM
S.A.F.E. FAMILY SMOKE ALARM FOR EVERY FAMILY INSTALLATION PROGRAM Page 1 A smoke alarm installation program implemented throughout Manitoba can make a difference by reducing injuries and/or deaths in a
PHOTOELECTRIC TYPE SINGLE STATION/MULTI-STATION SMOKE ALARMS/AC POWERED WITH BATTERY BACK-UP, 120VAC/9VDC, 60Hz OR 220VAC/9VDC, 50/60Hz
9000 SERIES PHOTOELECTRIC TYPE SINGLE STATION/MULTI-STATION SMOKE S/AC POWERED WITH BATTERY BACK-UP, 120VAC/9VDC, 60Hz OR 220VAC/9VDC, 50/60Hz Installation Instructions - Owner's Information READ CAREFULLY
Manual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327