1 Liquiphant M FTL50, FTL5 Level Limit Switch BA23F/24/ae/
2 Liquiphant M FTL50 / FTL5 Table of Contents Safety Instructions Order Codes Installation Setup Maintenance & Cleaning Technical Data Troubleshooting Spare Parts Supplemental documentation 2 Endress+Hauser
3 Liquiphant M FTL50 / FTL5 Safety Instructions Safe and secure operation of the unit can only be guaranteed if the operating instructions and all safety notes are read, understood and followed.. Approved usage The Liquiphant M FTL50 and FTL5 is designed for level limit detection in liquids. If used incorrectly, it is possible that application-related dangers may arise. The level limit switch Liquiphant M FTL50 and 5 may be installed, connected, commissioned, operated and maintained by qualified and authorized personnel only, under strict observance of these operating instructions, any relevant standards, legal requirements, and, where appropriate, the certificate..2 Safety pictograms and symbols " Safe and reliable operation of this unit can only be guaranteed if the safety hints and warnings in these operating instructions are followed. The safety hints in these instructions are highlighted using the following symbols: Caution! This symbol indicates activities and actions that, if followed incorrectly, could lead to faulty operation or even damage to the unit.! Note! This symbol indicates activities and actions that, if followed incorrectly, could have an indirect influence on the unit operation or could lead to an unforeseen unit reaction. 0-. Non-hazardous Hazardous area, certified equipment! If this character is shown on the unit, then it may be operated in hazardous areas. area! This symbol identifies the non-hazardous areas in these instructions. Units that operate in the nonhazardous areas but that are connected to the hazardous areas must also be certified. Hold by housing, flange or extension tube.3 Handling ka43y02ae.eps Endress+Hauser 3
4 Liquiphant M FTL50 / FTL5 Do not bend. Do not shorten. Do not lengthen KA43Y03ae.eps 2 Order Codes Product structure Design Basic weight FTL50 Compact.3 lb 0.6 kg FTL5 With extension pipe.3 lb 0.6 kg 0 Certificates, applications A Version for non-hazardous area P FM IS, Class I, II, III Division, Group A-G Q FM XP, Class I, II, III Division, Group B-G, for E5 housing Group A-G R FM NI, Class I Division 2, Group A-D S CSA IS, Class I, II, III Division, Group A-G T CSA XP, Class I, II, III Division, Group A-G U CSA General Purpose Y Special version ATEX and TIIS certified units available on request 20 Process connection, material Additional weight Note: For 450 psi (00 bar) process pressure, please select the appropriate option under "Additional option" Installation in welding neck accessory GM2 ¾" NPT Thread ANSI 36L GM5 ¾" NPT Thread ANSI Alloy C4 GN2 " NPT Thread ANSI 36L 0.4 lb 0.2 kg GN5 " NPT Thread ANSI Alloy C4 0.4 lb 0.2 kg A82 " 50 lb RF Flange ANSI B6.5 36/36L 2.2 lb.0 kg AA2 -¼" 50 lb RF Flange ANSI B6.5 36/36L 2.6 lb.2 kg AB2 -¼" 300 lb RF Flange ANSI B6.5 36/36L (FTL 5) 4.4 lb 2.0 kg AC2 -½" 50 lb RF Flange ANSI B6.5 36/36L 3.3 lb.5 kg AD2 -½" 300 lb RF Flange ANSI B6.5 36/36L (FTL 5) 6.0 lb 2.7 kg AE2 2" 50 lb RF Flange ANSI B6.5 36/36L 5.3 lb 2.4 kg AE5 2" 50 lb RF Flange ANSI B6.5 Alloy C4 >36/36L 5.3 lb 2.4 kg AF2 2" 300 lb RF Flange ANSI B6.5 36/36L 7. lb 3.2 kg AG2 2" 600 lb RF Flange ANSI B6.5 36/36L (FTL 5) 9.3 lb 4.2 kg AJ2 2-½" 300 lb RF Flange ANSI B6.5 36/36L (FTL 5) 0.6 lb 4.8 kg AL2 3" 50 lb RF Flange ANSI B6.5 36/36L 0.8 lb 4.9 kg AM2 3" 300 lb RF Flange ANSI B6.5 36/36L (FTL 5) 5 lb 6.8 kg AN2 3" 600 lb RF Flange ANSI B6.5 36/36L (FTL 5) AP2 4" 50 lb RF Flange ANSI B6.5 36/36L 5.4 lb 7.0 kg AQ2 4" 300 lb RF Flange ANSI B6.5 36/36L (FTL 5) 25.4 lb.5 kg AR2 4" 600 lb RF Flange ANSI B6.5 36/36L (FTL 5) 38. lb 7.3 kg TC2 DN ( to -½") ISO 2852 Tri-Clamp 36L 0.2 lb 0. kg TE2 DN 40-5 (2") ISO 2852 Tri-Clamp 36L 0.7 lb 0.3 kg YY9 Special version Other process connections available, contact Endress+Hauser 4 Endress+Hauser
5 Liquiphant M FTL50 / FTL5 30 Length, spacer, pressure tight bushing FTL50 AA Compact Ra <3.2 µm/80 grit IA 66 mm / 2.6" + temperature spacer.3 lb 0.6 kg QA 66 mm / 2.6" + pressure tight bushing.5 lb 0.7 kg FTL5 CB... in (6 in to 5 in) Ra 3.2 µm 36L** CE... in (6 in to 5 in) Ra 3.2 µm Alloy C4** 5 lb (2.3 kg)/00 in DB Length II* Ra 3.2 µm 36L 0.2 lb 0. kg DE Length II* Ra 3.2 µm Alloy C4 0.2 lb 0. kg KB KE LB LE SB SE TB TE YY... in (6 in to 5 in) + temperature spacer... in (6 in to 5 in) + temperature spacer Length II* + temperature spacer Length II* + temperature spacer... in (6 in to 5 in) + pressure tight bushing... in (6 in to 5 in) + pressure tight bushing Length II* + pressure tight bushing Length II* + pressure tight bushing Special version 36L** 36L** 36L Alloy C4 36L** Alloy C4** 36L Alloy C4 *) Replacing instruments: when vertically mounting a Liquiphant M FTL5 with length II, the switch point is at the same height as for the Liquiphant II FTL360, FTL365, FDL30, FDL35 **) order 300 to 6000 mm (6 to 235 in) via yy 5 lb (2.3 kg)/00 in +.3 lb (+0.6 kg) 5 lb (2.3 kg)/00 in +.3 lb (+0.6 kg) 0.2 lb +.3 lb 0.2 lb +.3 lb 0. kg +0.6 kg 0. kg +0.6 kg 5 lb (2.3 kg)/00 in +.5 lb +0.7 kg 5 bl (2.3 kg)/00 in +.5 lb +0.7 kg 0.2 lb +.5 lb 0.2 lb +.5 lb 40 Electronic insert FEL5* Contact-free two-wire, 9 to 253 V AC 2 FEL52* PNP three-wire, 0 to 55 V DC 4 FEL54 Floating change-over contacts, DPDT, 9 to 253 V AC, 9 to 55 V DC 5 FEL55 8/6 ma, to 36 V DC 6 FEL56 NAMUR 7 FEL57 Two-wire PFM 8 FEL58* NAMUR with push button (disconnects wire) 9 Special version 0. kg +0.7 kg 0. kg +0.7 kg *) Also available in compact housing 50 Housing, cable entry C3 Compact housing 36L IP66/68 5m cable D3 Compact housing 36L IP65 Pg connector E3 Compact housing 36L NEMA4x NPT/2" connector N3 Compact housing 36L IP66/68 M2 connector E4 Polyester housing Nema 4x, NPT ½" E5 Aluminum housing Nema 4x,NPT ¾". lb/0.5 kg E6 36L housing Nema 4x, NPT ½" 0.2 lb/0. kg E7 Aluminum housing IP66 NPT ¾", 2.0 lb/0.9 kg with separate connection compartment Y9 Special version 60 Additional fittings A No additional fittings C 3..B material, wetted parts 36L, Inspection certificate to EN 0204, in accordance with Specification N NACE 3..B P 450 psi (00 bar) process pressure (FTL5) R 450 psi (00 bar) process pressure, EN material, NACE MR075 (36L wetted parts) (FTL5) Inspection certificate S GL marine approval (FTL 5: max. length 63"/600 mm) Y Special version FTL 5# - Complete product designation Endress+Hauser 5
6 Liquiphant M FTL50 / FTL5 3 Installation 3. Application Level limit detection in liquids "T" KA43Y0ae.eps 3.2 Measuring System For direct connection Order code: FTL5#-###### # ### Electronic inserts FEL 5 FEL 52 FEL 54 External load KA43Yae.eps 6 Endress+Hauser
7 Liquiphant M FTL50 / FTL5 For connection via switching unit Order code: FTL5#-###### # ### Electronic insert FEL 55 FEL 56 FEL 57 FEL 58 KA43Y2ae.eps I.S. *) Switching unit, PLC, *) isolating amplifier FTL, SIF, SIN, FXN EX EX KA43Y3ae.eps 3.3 Installation Switchpoint depends on mounting position KA43Y5ae.eps! Note! The switchpoints of the Liquiphant M are at different positions than those of the previous version Liquiphant II. Endress+Hauser 7
8 Liquiphant M FTL50 / FTL5 Mounting examples as a function of liquid viscosity = cp min. 2" (min. DN 50) * * min. in ( min. 25 mm) *Deburr = 0-0,000 cp min..5 in (min. 40 mm) KA43Y6ae.eps Consider buildup. Fork may not contact the buildup * * *Distance KA43Y7ae.eps 8 Endress+Hauser
9 Liquiphant M FTL50 / FTL5 In cases of dynamic forces support KA43Y8ae.eps Allow clearance "T" = with temperature spacer for insulated tanks "T" KA43Y9ae.eps Endress+Hauser 9
10 4 4 Liquiphant M FTL50 / FTL5 Orientation of fork tines: marking above or below KA43Y20ae.eps, KA43Y2ae.eps Screw Liquiphant into process connection. DON T use housing to turn. G ¾ A, SW ¼" ( 32 mm) G A, SW 5 8 " ( 4 mm) ¾ NPT, R ¾, G ¾ A, SW ¼" ( 32 mm) Above or below NPT, R, G A, SW 5 8 " ( 4 mm)! PTFE T EFLON A B KA43Y22ae.eps 0 Endress+Hauser
11 2 Liquiphant M FTL50 / FTL5 Orientation in pipes: marking in direction of flow Ø min. 2" (ø min. 50 mm) Max. 6 ft/s (max. 5 m/s ) KA43Y23ae.eps Cable entry orientation F5 3to4 turns Nm* *Torque F6, F3, F KA43Y24ae.eps Endress+Hauser
12 Liquiphant M FTL50 / FTL5 4 Setup Minimum/maximum failsafe mode Max. Max. 0V Min. Min. KA43Y25ae.eps Liquid density. Density ρ measured in g/cm 3 (SGU) or in kg/l FEL 5, FEL 52, FEL 54, FEL 55, FEL 56, FEL 57, FEL 58 > 0.7 ( 5.9 lbs.) US gal 5.9 lbs US. gal = min. 5.9 lbs ( l ( dm³) = min 0.7 kg) ( imp.gal = min. 7.0 lbs) Standard 0V US gal 4.2 lbs > 0.5 US. gal = lbs ( lbs.) ( imp.gal = lbs) ( l(dm³) = kg) e.g. Propane KA43Y26ae.eps 2 Endress+Hauser
13 Liquiphant M FTL50 / FTL5 Self test FEL57 FEL 57 (See page 2 and switching unit for sequence) STD Standard ~8s Switching unit + ~4s With corrosion test EXT KA43Y27ae.eps 4. Display elements KA43Y38ae.eps Endress+Hauser 3
14 Liquiphant M FTL50 / FTL5 4.2 Connections, Function Note national regulations! FEL Max. AWG 4 (Max. 2,5 mm² ) Max. AWG 2 (Max. 4 mm² ) /8 in ( 3 mm) KA43Y29ae.eps 4 Endress+Hauser
15 Liquiphant M FTL50 / FTL5 Connections FEL5 Two-wire AC connection KA43Y30ae.eps Function FEL5 KA43Y39ae.eps V FEL5 max. 3V Endress+Hauser 5
16 Liquiphant M FTL50 / FTL5 Connections FEL52 DC connection (PNP) Function FEL52 KA43Y40ae.eps KA43Y3ae.eps V FEL52 max. 3V 6 Endress+Hauser
17 Liquiphant M FTL50 / FTL5 Connections FEL54 Universal connection Relay output KA43Y32ae.eps Function FEL54 FEL GN RD FEL 54 Max Min V 0 V KA43Y4ae.eps Endress+Hauser 7
18 + Liquiphant M FTL50 / FTL5 Connections FEL55 Output 8/6 ma FEL 55 2 FM IS EX Hazardous Area Non-Hazardous Area EX e.g. PLC, AI modules R R max. = V 6.8 ma - 36 VDC KA43Y33ae.eps Function FEL55 FEL 55 2 GN RD FEL ~ 6 ma Max. + 2 ~ 8 ma + 2 ~ 6 ma Min. + 2 ~ 8 ma + 2 < 3.6 ma KA43Y42.eps 8 Endress+Hauser
19 Liquiphant M FTL50 / FTL5 Connections FEL56 NAMUR output L-H <.0 ma / >2.2 ma FEL 56 2 FM IS EX Hazardous Area L H I + Non-Hazardous Area EX e.g. FXN 42, FXN 422, SIN 00, SIN 0 FTL 325N, FTL 375N L H ma ma Isolating amplifier to NAMUR (IEC ) KA43Y34ae.eps Multiplexer: pulse duty cycle minimum 2 s Function FEL56 FEL 56 2 GN RD FEL ma Max ma ma Min ma ma KA43Y43ae.eps Endress+Hauser 9
20 Liquiphant M FTL50 / FTL5 Connections FEL57 PFM output 50 Hz/50 Hz FEL 57 2 Note function! See page 2 FM IS EX Hazardous Area H H 50 Hz f Non-Hazardous L Area EX L 50 Hz d4 d2 + Nivotester FTL 320, FTL 20Z FTL 325 P CH FTL 325 P CH3 FTL 370/372, FTL 70Z FTL 375 P CH Input z4 z2 FTL 372, FTL 70Z FTL 375 P CH2 Input 2 z6 2 d6 FTL 375 P CH3 Input 3 Commutec S SIF 0, SIF KA43Y35ae.eps Function FEL57 FEL 57 GN YE FEL 57 I 50 Hz I 50 Hz t * V 0V 2 *Switch-on behavior I I 0Hz 0Hz t t t See page 2 KA43Y44ae.eps 20 Endress+Hauser
21 Liquiphant M FTL50 / FTL5 Switch-on behavior STD (Self test) FEL 57 STD Simulation s 4s 3s FEL 57 0 Hz 50 Hz 50 Hz 50 Hz Simulation FEL 57 s 7s 0Hz 50Hz 50Hz KA43Y45ae.eps Switch-on behavior EXT (Self test) FEL 57 EXT Simulation s 4s 30s 6s FEL 57 0 Hz 50 Hz 50 Hz 0 Hz 50 Hz Simulation FEL 57 s 34 s 6 s 0 Hz 50 Hz 0 Hz 50 Hz KA43Y47ae.eps Endress+Hauser 2
22 Liquiphant M FTL50 / FTL5 Connections FEL58 NAMUR output H-L >2.2 ma / <.0 ma FEL 58 2 FM IS EX Hazardous Area L H I Non-Hazardous Area EX L H ma ma + e.g. FXN 42, FXN 422, SIN 00, SIN 0 FTL 325 N, FTL 375 N Multiplexer: pulse duty cycle minimum 2 s Isolating amplifier to NAMUR (IEC ) KA43Y36ae.eps Function FEL58 FEL 58 2 GN YE FEL 58 Max. Min. Hz Hz Hz Hz 0.3 Hz ma ma ma ma <.0 ma KA43Y49ae.eps 22 Endress+Hauser
23 Liquiphant M FTL50 / FTL5 Function test button FEL58 Fail-safe mode MAX MAX + T. Normal operation GN YE GN YE Ex d T * T Hz ma Hz ma 2. Press test button >3 s GN YE GN YE + 2 0mA + 2 0mA 3. Release the test button, after ~2 s normal operation GN YE GN YE Hz ma + 2 Hz ma KA43Y64ae.eps Function test button FEL58 Fail-safe mode MIN MIN + T. Normal operation GN YE GN YE Ex d T * T Hz ma Hz ma 2. Press test button >3 s GN YE GN YE + 2 0mA + 2 0mA 3. Release the test button, after ~2 s normal operation GN YE GN YE Hz ma + 2 Hz ma KA43Y65ae.eps Endress+Hauser 23
24 Liquiphant M FTL50 / FTL5 5 Maintenance & Cleaning Removal of encrustation KA43Y53ae.eps Do not use as a step! KA43Y54ae.eps 24 Endress+Hauser
25 Liquiphant M FTL50 / FTL5 6 Technical Data Ambient temperature T a Process temperature T p Ta Ta F 58 F ( 70 C) 22 F ( 50 C) Available when used with temperature spacer. See order codes. Tp 32 F 58 F 32 F 94 F 300 F ( 50 C) ( 0 C) ( 90 C) ( 50 C) 58 F ( 50 C) TP F KA43Y55ae.eps Process pressure p e Process temperature T p p e psi (bar) FTL5-# ### ## # ## P FTL5-# ### ## # ## R See order codes 450 ( 00) 928 ( 64) 58 ( 50) 4.5 ( ) 32 ( 0) 300 ( 50) T p F ( C) KA43Y70ae.eps 6. Accessories Weld-in sockets Ø.26 G¾ (ø32) ISO (26) 0.83 (2) Ø (Ø55 ) G¾ E+H max. 360 psi/300 F (max. 25 bar/50 C) max. 580 psi/20 F (max. 40 bar/00 C).6 (29.6) 0.97 (24.6) G E+H Ø.6 G (ø4) ISO 228 Ø ( Ø 60 ) (26) G E+H Ø ( Ø 65 ) Dimensions are in inches (mm) 0.20 (5) KA43Y56ae.eps Endress+Hauser 25
26 Liquiphant M FTL50 / FTL5 Lap joint flanges with BSP (G) thread; Covers with window Corrosion-resistant steel.457 (AISI 36 Ti) Lap joint flange with G thread 2, 50 psi, RF, ANSI B 6.5 E+H PA 2 Transparent cover For plastic housing E+H Glass AISI 36 L (.4435) Stainless steel cover with glass window For stainless steel housing E+H PC AISI 36 L (.4435) With polycarbonate window E+H KA43Y58ae.eps Sliding sleeves for unpressurized operation 0.75 (9) G E+H ½ NPT E+H See KA5F (G, NPT ) See KA52F (G ½, NPT ½) 0.7 (8) M6 (3x).6 (4) Ø0.86 (2.8).4435 (AISI 36 L) G½ E+H ½ - ½ NPT E+H p e = 0 psi (p = 0 bar) e max. 300 F (max. 50 C) 0.75 (9) 0.87 (22) M6 (3x) 2.6 (55) Ø0.86 (2.8).4435 (AISI 36 L) KA43Y59ae.eps 26 Endress+Hauser
27 Liquiphant M FTL50 / FTL5 High pressure sliding sleeves G.4435 (AISI 36 L) E+H Alloy C4 E+H ½ NPT.4435 (AISI 36 L) E+H Alloy C4 E+H See KA53F (G, NPT ) See KA54F (G ½, NPT ½) ~2.75 (70) Ø2.36 (60) 0.08 (2) 0.7 (8) 0.98 (25) G½.4435 (AISI 36L) E+H Alloy C4 E+H ½ - ½ NPT.4435 (AISI 36L) E+H Alloy C4 E+H ~2.83 (72) Ø2.36 (60) 0.08 (2) 0.86 (22) 0.98 (25) KA43Y60ae.eps High pressure sliding sleeves: Process pressure p e Process temperature T p psi (bar) 450 (00) 60 (80) 928 (64) Liquiphant S Liquiphant M -76 (-60) -58 (-50) -4.5 (-) 32 (0) 300 (50) 500 (260) 540 (280) F ( C) KA43Y69ae.eps Endress+Hauser 27
28 Liquiphant M FTL50 / FTL5 7 Troubleshooting Fault Reason Remedy Does not switch No power Check power Faulty signal line Faulty electronic insert FEL5 connected directly to L and N Density of liquid too low Fork encrusted Fork corroded (Indication on FEL: red/yellow flashes, FEL58: green flashes (0.3 Hz) FEL5: Internal resistance of connected relay too large FEL5: Holding current of connected relay too low FEL54: Contacts welded together (after short-circuit) Check signal line Exchange always connect FEL5 via external load Set density to >0.5 at electronic insert Clean fork Exchange fork and process connection Connect suitable relay Connected resistor in parallel with relay Exchange FEL54; put fuse in contact circuit Switches incorrectly Min-/Max- fail-safe mode set wrong Set correct mode at electronic insert Sporadic faulty switching Thick heavy foam, very turbulent conditions, foaming liquid Extreme RFI Mount Liquiphant in bypass Use shielded cable Extreme vibration Decouple, damp, turn fork 90 Switches incorrectly after power failure Water in housing FEL52: Output overloaded FEL57: behavior during switch-on test (functional test) Screw cover and cable gland tight Reduce load, (cable) capacitance Observe switching behavior of FEL57; after power failure block plant control for up to 45 s Troubleshooting Supplement If the switching behavior of the fork is abnormal, the fork frequency can be measured at PIN 4 of the diagnosis socket. With electronic inserts FEL 5/52/54/55/56/57/58, this is a sinusoidal vibration whose amplitude makes it possible to determine the condition of the fork. 28 Endress+Hauser
29 Liquiphant M FTL50 / FTL5 8 Spare Parts Electronic inserts FEL FEL FEL FEL FEL FEL FEL KA43Y6ae.eps Installation specification: During installation, please keep in mind that electrical resources (electronic inserts) which are powered by non-intrinsically-safe circuits may no longer be interconnected with intriniscally-safe circuits. Housing covers, seals Alu Alu w/epdm O-ring E+H * * EPDM Alu (EX) w/epdm O-ring E+H PBT-FR (cover only) E+H EPDM O-ring E+H * * Lubricate with silicone grease or graphite. AISI 304/36L E+H (cover only) (.430/.4435) MVQ Silicone Seal E+H KA43Y62ae.eps 9 Repair Repair is done at Endress+Hauser. Clean 2. Transport protection 3. Endress+Hauser KA43Y63ae.eps Endress+Hauser 29
30 Liquiphant M FTL50 / FTL5 0 Supplemental Documentation Technical Information TI328F Liquiphant FTL50, FTL50H, FTL5, FTL5H Notes on Safety XA03F 4 0 II /2 G EEx d IIC/IIB XA063F 4 0 II /2 G, II /2 D EEx ia/ib IIC/IIB XA064F 4 0 II G EEx ia IIC/IIB XA08F 4 0 II /2 G EEx de IIC/IIB XA54F 4 0 II /2 G, II /2 D EEx ia/ib IIC/IIB XA59F 4 0 II G EEx ia IIC/IIB XA82F 4 0 II 3 G, II 3 D EEx na/nc II 30 Endress+Hauser
31 Liquiphant M FTL50 / FTL5 Endress+Hauser 3
32 United States Canada Mexico Endress+Hauser, Inc Endress Place Greenwood, IN 4643 Tel: Sales: 888-ENDRESS Service: FAX: Endress+Hauser Canada 075 Sutton Drive Burlington, ON L7L 5Z8 Tel: FAX: Endress+Hauser Mexico, (Mexico) S.A. de C.V. Av. Calle Gustavo de Gustavo Baz No. Baz 43 No. 43 Fracc. Fraccionamiento Bosques de Bosques Echegaray de Echegaray Naucalpan CP 5330 de Naucalpan Juaraz, C.P. de Juárez 5330 Estada Mexico de Mexico Mexico Tel: Phone: (52) FAX: FAX: (52) [email protected] BA23F/24/ae/ FM+SGML 6.0
Liquid Level Limit Switch liquiphant T FTL 20
Technical Information TI 64F/4/ae Liquid Level Limit Switch liquiphant T FTL 0 Level limit switch for liquids Applications The Liquiphant T FTL 0 is a level limit switch for virtually any kind of fluid
Technical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
Minicap FTC260, FTC262
Technical Information Minicap FTC260, FTC262 Capacitive Limit Detection Compact switch for limit detection with active build-up compensation; No calibration necessary Version available for dust explosion
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
Compact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
3DLevelScanner II TECHNICAL DATA SHEET
TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Level Switch soliphant II FTM 30, FTM 31, FTM 32
Technical Information TI 29F/2/ae Level Switch soliphant II FTM 0, FTM, FTM 2 Cost-effective vibration level switch for fine-grained bulk solids Application Soliphant II is a rugged level switch for use
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Linear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
RTD Temperature Probe for the Food/Pharmaceutical Industry
[email protected] Data Sheet 902810 Page 1/9 RTD Temperature Probe for the Food/Pharmaceutical Industry For temperatures between -50 and +250 C Protection type up to IP69 according to DIN EN 60529 (IP69K
Flow switches Series AD/VH
Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,
Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor
Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =
Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.
Dimensions LUC-M20 with F12 housing and process connection 2" approx. 86 65 78 Ø129 150 AF60 85 G2 2 NPT 22 ~148 Ø50 ~83 Additional dimensions see section dimensions. Features Quick and simple commissioning
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
Linear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
Design. Function. Transmitter. Operating and display panel. HART communication. Master
Siemens AG 2013 Flow Measurement Overview Design The transmitter is designed as either IP67 NEMA 4X/6 enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack
Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau
KA 180F/00/en/06.01 (a) 52010984 Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau Safety instructions The FTS 20 floating switch may only be used as a level limit switch
Variable Area Flowmeters
www.swagelok.com Variable Area Flowmeters G Series and M Series Glass and metal (armored) tube models, including miniature armored model Highly accurate measurement with individually calibrated scales
Temperature Switch Thermophant T TTR 31, TTR 35
Technical Information Temperature Switch Thermophant T TTR 3, TTR 35 Temperature switch for the safe measurement, monitoring and control of process temperatures Application Temperature switch for the monitoring,
Micro Motion Model D and DL Coriolis Flow and Density Meters
Product Data Sheet PS-00388, Rev. F April 2013 Micro Motion Model D and DL Coriolis Flow and Density Meters Micro Motion Model D and DL sensors provide flow and density measurement for liquids, gases,
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
Pressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
SEISMIC VELOCITY TRANSDUCER T1-40
SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
SITRANS F flowmeters SITRANS F M
Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update
Temperature sensor with integrated transmitter for industrial applications, MBT 3560
Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment
Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370
Pump_TM016 Pump Local Display TM0200 TM0200 4-20mA PLC/DCS Case 1 Pump Relay Output Module 4-20mA Optional PT371 Modbus PT373 Case 2 PCM370 TM016 Velocity/ Acceleration Vibration Transmitter Introduction
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
Turbine Flow Sensor Series VTR
Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates
SITRANS F flowmeters SITRANS F M. Transmitter MAG 5000/6000. 4/32 Siemens FI 01 2010. Overview
Overview Design The transmitter is designed as either IP67 NEMA X/6 enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack systems Panel mounting IP20/NEMA
Operating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
Technical Data Sheet. 3DLevelScanner
Changing the market from level to volume Technical Data Sheet APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
Terminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
Relative and absolute pressure switch type 529
Relative and absolute pressure switch type 529 Pressure range -1... 0 60 bar The compact type 529 pressure switch is based upon the Huba Control developed unique ceramic technology used for the last 20
Plug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve
Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve ANSI version Application Control valve especially designed for controlling low flow rates in pilot plants and technical research
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Machine Safety Switches
Machine Switches SI-LS31H Series 31 mm Limit-Switch-Style with Hinged Lever Actuators Features Limit switch design (EN 50047) For use on doors or flaps Positive opening safety contacts (IEC 60947-5-1)
EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL
PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex
Centro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures
SX 8 The SX range comprises 14 sizes of enclosure manufactured in either stainless steel or mild steel. 11 sizes are available in depths of 140 or 200mm and 8 sizes are available in depths of 140, 200
Solenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
Differential-Hall-Effect based Sensors Series A5S
Speed and Frequency Seite 1 von 6 Differential-Hall-Effect based Sensors Series A5S Outstanding Characteristics Speed range covering most demands: from close to zero up to 25,000 pulses/second (response
Assisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass
Order Code for GEA Tuchenhagen VESTA Sterile Valves. Type H_A 2/2 Way Seat Valve
Order Code for VESTA Sterile Valves Type H_A 2/2 Way Seat Valve engineering for a better world GEA Mechanical Equipment VESTA Sterile Valves are designed for universal use in sterile process technology.
Conductive Level Switch FK 2 Technical Data:
Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
2 & 5-Wire Overfill Sensors
2 & 5-Wire Overfill Sensors Optic overfill sensors detect the presence of liquid at a preset level. The new Civacon Universal 2 & 5-Wire Sensor is fully compatible with all our current Sensors and Monitors,
Operating Instructions for Plastic Flow Meter. Model: KSK
Operating Instructions for Plastic Flow Meter Model: KSK 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...
PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100
Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When
PROCESS AUTOMATION LEVEL MEASUREMENT VIBRATION AND GUIDED MICROWAVE
PROCESS AUTOMATION LEVEL VIBRATION AND GUIDED MICROWAVE POINT LEVEL DETECTION VIBRACON MINI VIBRATION FORK TECHNOLOGY The world s smallest vibrating fork sensor offers premium point level control performance
98371000 REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN 46515 (574) 295-8330 FAX (574) 293-9914 2011 ELKHART BRASS MFG. CO., INC.
81471067 Electric Monitor Motor Control Panel For use with Model 8394059 SPIT-FIRE Monitor Installation, Operation, and Maintenance Instructions FOR ATEX APPLICATIONS 1302 WEST BEARDSLEY AVENUE P.O. BOX
ZS10 Screw Clamp Terminal Block
Technical Datasheet 1SNK 161 004 D0201 ZS10 Screw Clamp Terminal Block Feed-through Catalogue Page 1SNK 161 004 S0201 10 mm² 6 AWG 8 mm 0.315 in Spacing Features and Benefits 53 2.09" Save space by connecting
200350 and 200355 Accelerometers
and Accelerometers Bently Nevada Asset Condition Monitoring Description The and Accelerometers are general purpose, casemounted seismic transducers designed for use with Trendmaster Pro Constant Current
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES
2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:
PNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
TEIP11 I/P signal converter for standard signals. Measurement made easy
Data Sheet 10/18-0.11-EN Rev. B TEIP11 I/P signal converter for standard signals Measurement made easy Current in air pressure Proven and reliable concept Compact design Small dimensions, low weight Sturdy
Control- and feedback head for integrated mounting on Robolux valves Type 2036
Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
Technical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****
Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** FM 3046039 Class I Div 1, Groups A, B, C and D Class II Div 1, Groups E, F and G; Class III Class I, Zone 0, AEx ia IIC Ga, Ga/Gb, Gb Document ID:
Instruction Manual. T3111 T3111L T3111P T3111Ex
www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
ph/redox Measurement MyPro CPM 431
Technical Information TI 173C/07/en/06.02 50088309 ph/redox Measurement MyPro CPM 431 Two-wire transmitter for ph and redox with Hart and PROFIBUS-PA communication for use in Ex and non-ex areas Application
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66
Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS 05.0008 Ex t IIIC T Da, Da/Db, Db IP 66 0044 37321 Contents 1 Area of applicability 4 2 General information 4 2.1 Zone 20 instruments
AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products
Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution
Machine Safety Switch: SI-LM40 Series Limit Switch Style
Machine Switch: SI-LM40 Series Limit Switch Style SI-LM40 Series Limit Switch Style with Flexible In-Line Actuator Positive-opening safety contacts (IEC 60947-5-1) (not dependent upon springs) Standard
NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES
NIVOCONT CONDUCTIVE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES APPLICATION Level switches, based on the conductivity principle, can be applied to liquids with conductivity
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly
DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters
Solenoid valves 2/2-way direct-operated Type EV210A
Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
Kit 106. 50 Watt Audio Amplifier
Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
Technical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element