Level Switch soliphant II FTM 30, FTM 31, FTM 32
|
|
|
- Gilbert Reed
- 9 years ago
- Views:
Transcription
1 Technical Information TI 29F/2/ae Level Switch soliphant II FTM 0, FTM, FTM 2 Cost-effective vibration level switch for fine-grained bulk solids Application Soliphant II is a rugged level switch for use in silos containing fine-grained and powdery solids, including those with very low bulk densities. The various versions ensure it can be used in a wide range of applications, including dust, explosion areas and foodstuffs. Typical applications include grain, flour, milk powder, cocoa, sugar, animal feed, washing powders, dyes, chalk plaster, cement, and plastic granules. FTM 0 Compact version for mounting at any orientation FTM with extension tube (up to 55 inches) for top mounting in silos or tanks Features and Benefits No calibration: quick and low-cost start-up Insensitive to build-up: maintenance free No mechanical moving parts: no wear, long operating life Choice of various electronic inserts: optimum adaptability to the plant process Plastic housing with transparent cover: switching status seen externally, simple control Aluminum housing with separate electrical connection compartment: designed for hazardous locations FTM 2 with cable for mounting up to 65 feet for top mounting in silos or tanks The Power of Know How
2 Measuring System The Soliphant II with the integrated electronic inserts (FEM 2, or 7) are a compact level switch that can be connected to miniature contactors, magnetic valves and programmable logic controllers (PLCs). The electronics are dust-ignition proof and can be mounted in hazardous areas. FTM with FEM FTM 2 with FEM 2 + A Compact limit switch for two-wire AC power supply FTM 0 with FEM B Compact limit swtich for three-wire DC power supply I PFM t C Compact limit switch for AC or DC power supply D Limit switch as intrinsically safe version with remote switching unit FTM 0 with FEM 7 Nivotester FTL Function The symmetrical vibrating fork is excited to its resonant frequency. Vibration characteristics change when the fork is submerged in solid material. The change is registered by the electronics which actuate an electronic switch or relay. The tip of the Soliphant fork is particularly sensitive, while the base of the fork is completey insensitive. This enables solids with very low density to be detected even with material build-up on the vessel walls. Fail safe mode Electronic Insert Electronic Insert Electronic Insert FEM FEM FEM 2 FEM FEM Red LED FEM 5 FEM 5 Red LED Green LED FEM 7 Green LED The function of the electronic switch or relay and LED depends on the level and fail-safe mode. The electronic insert FEM 7 changers the frequency of the PRM signal causing the Nivotestor FTL to switch accordingly. Maximum Minimum L+ + L+ L+ L Hz 50 Hz 50 Hz 50 Hz V 2 L+ 5 V 0V The Soliphant can be operated in both minimum or maximum fail-safe mode, i.e. the electronic switch opens or the relay de-energizes when the minium or maximum level is reached, on fault or on power failure. 2
3 ENDRESS + HAUSER ENDRESS + HAUSER Mechanical and Electrical Versions Application according to approvals FTM - Standard application - Dust Ex area Zone 0 FTM.. D - Standard application - Dust Ex area Zone 0 - Ignition protection EEx de FTM.. S - Standard application - Dust Ex area Zone 0 - Ignition protection EEx i PFM Plug-in electronic insert options simple to replace with another electronic insert, without recalibration Two-wire AC power supply (thyristor) FEM for FTM 0, 0 D,, 2 FEM for FTM D, 2 D, 2 dust-ex Three-wire DC power supply (transistor, PNP) FEM 2 for FTM 0,, 2 and FTM 0 D (not for FTM 2 dust Ex) Universal power supply (relay changeover contact) FEM for FTM 0, 0 D,, 2 FEM for FTM D, 2 D, 2 dust-ex Universal power supply (2-relay changeover contacts) FEM 5 for FTM 0,, 2, 0 D, D, 2 D FEM 5 for FTM 2, FTM 0 D, D, 2 D Intrinsically safe signal transmission along two-wire power cable to remote Nivotester switching unit FEM 7 for FTM 0 S, S, 2 S Housing all with NEMA X protection and a wide range of conduit entries Aluminum housing F6 for FTM.. and FTM.. S Plastic housing F0 with transparent cover for FTM.. and FTM.. S Aluminum housing T with separate connection compartment for FTM.. D, FEM 5 / 5 Aluminum housing T with separate connection compartment for FTM.. D and FTM.. S 0 SS housing F8 for FTM.. S, FEM 7 Process connections Tapered thread -/2 - -/2 NPT Tapered thread R -/2, DIN 2999 Various flanges, ANSI, JIS, and DIN Sensor options vibrating fork in solid stainless steel, resistant to lateral loads FTM 0 compact unit FTM with extension tube FTM with optional sliding sleeve FTM 2 with cable (can be shortened)
4 Installation Guidelines Soliphant FTM 0 The compact Soliphant version can be mounted at any position in a bulk solids vessel. Correct Mounting, a, b, c, d a) top-mounted, tines vertical but at any orientation b) laterally mounted, fork slightly angled downward so that material can slide off easily. Maximum nozzle length is 2." (60 mm) c) side mounted with roof to protect against collapsing material mounds d) bottom mounted in angle portion of discharge hopper b) c) a) d) 7.9" (200) 7.9" (200) " (200) e) f) g) Incorrect Mounting, e, f, g e) mounted in filling curtain f) fork orientation incorrect (flat surface is subjected to excessive load, and false switching due to residual material) g) mounting nozzle is too long, allows material to build up inside nozzle causing false switching. NOTE: Take into account the angle of mound or discharge hopper when determining the height of the installation point Soliphant FTM With extension tube: If mounting is only possible from the top; With heavy build-up on the side wall; With optional sliding sleeve when the switch point is to be altered. Mount in the center of the discharge hopper in order to keep the lateral load from the discharging material to a minimum. If mounting closeto the vessel wall, fasten theextension pipe near the fork. Ensure there is enough space above the vessel for mounting. Sliding Sleeve FTM FTM 2 Soliphant FTM 2 With cable: Used in tall silos when top mounting is only available Used when there is not enough clearance above the vessel to mount an extended version of the FTM. The Soliphant should be mounted near the vessel wall to keep excessive tension from discharging material to a minimum. It should not be mounted too close to the wall to prevent the fork from hitting the wall when it swings. FTM
5 Electrical Connection 9 to 25VAC L N NOTE The diagrams show the direct connection of the electronic insert into the F6 or F0 housing. The terminals in the second connection compartment of the T housing have the same designations as the built-in electronic inserts. FEM, FEM electronic insert Two-wire, AC power supply. Always connect in series with load FEM 2 electonic insert Three-wire, DCpower, for use with programmable logiccontrollers (PLC).Positive signal at the switching output of the electronic insert (PNP) 2 FEM / 0 to 55VDC L+ L 2 ( + ) 9 to 25VAC 9 to 200VDC L N (AC) L+ N- (DC) NO C NC 2 5 The terminal voltage at the electronic insert must not be below 9 V. Note the voltage drop across the electronic insert in the conducting state (max. 2 V), the residual current in the blocked state (max. ma) and, when using low voltages, the voltage drop across the load. FEM, FEM Universal power supply with relay output. Potential-free relay contact FEM 2 FEM / FEM 5, FEM 5 Universal power supply with DPDT relay output. Potential-free relay contact NO C NC 9 to 25VAC 9 to 200VDC L N (AC) L+ L- (DC) NO C NC 7 8 FTL 20 (or FTL 20 Z) safe area hazardous area FEM 7 electronic insert Intrinsically-safe PFM signal transmission through two-wire cable remote switching of Nivotester FTL I 2 PFM-Signal FEM 7 t FEM 5 / 5 FEM FEM 5/5 Plug-in electronic inserts can be exchanged without recalibration. Min Max t Min Max A B A B C D A LED shows switching status B Fail-safe mode is selected using switch A Time delay mode is selected using switch B Green LED indicates power on C Fail-safe mode is selected using switch D Red LED shows switching status 5
6 Dimensions A FTM 0 Compact version with threaded process connector shown with F 6 / F 0 style housing A 5." ()." (86).8" (98) 5.7" (5) B B FTM 0 Compact version with flange mount, shown with F 6 / F 0 style housing C FTM Extended version, with extension pipe and threaded process connector shown with T style housing 8.5" (26).7" ()." (28) SW 50 -/2" NPT 0.78" (20) 9.0" (20) 2." (60) D FTM Extended version, with extension pipe and flanged process connector shown with T style housing E FTM D Extended version with T housing with high top cover to accomodate the FEM 5 / FEM 5 F FTM 2 Extended version with cable and threaded process connector shown with F 6 / F 0 style housing G FTM 2 Extended version with cable and flanged process connector shown with F 6 / F 0 style housing C 6.2" (58).5" (0) -/2" NPT FTM, S: 2" to 55" (05 to 97) FTM D: 6" to 55" (06 to 97).6" (9).7" () SW 50." (28) 6.0" (5) FTM, S: 2" to 55" (05 to 97) FTM D: 6" to 55" (06 to 97)." (0) D 7." (88) FTM, S: 2" to 55" (05 to 97 FTM D: 6" to 55" (06 to 97) 5.6" (2) E 6.7" (70) 0.78" (20) 0.78" (20) F." (86).5" (0) G 5." () -/2" NPT SW 50.7" () 7.9" (20).9" (26) FTM 2, 2 S:.6" (8) FTM 2 D: 7." (88) FTM 2, 2 S: 0" to 790" (762 to 20066) FTM 2 D: 0" to 790" (000 to 20066) 0.9" (0).7" ()." (28) 6.7" (70) FTM 2, 2 S: 0" to 790" (762 to 20066) FTM 2 D: 0" to 790" (000 to 20066) FTM 2, 2 S:.6" (8) FTM 2 D: 7." (88).5" (0) 6
7 Technical Data General specifications Application Operation and system design Input Instrument types Intrument function Limit detection Measuring principle Modularity Signal processing Electrical isolation Measured variable Measuring range (detection range) FTM 0, FTM, FTM 2FTM 0 D, FTM D, FTM 2 D FTM 0 S, FTM S, FTM 2 S Level limit switch Maximum or minimum detection in silos with powdery and fine grained solids, maximum grain size of 9/6" ( mm). Damping of the oscillation of a fork vibrating at its resonant frequency FTM and FTM D versions: complete limit switch, consisting of the sensor with integrated electronic inserts FEM series. FTM S versions: sensor with integrated electronic insert FEM 7 (transmitter) for connection to remote switching unit Nivotester FTL series. Two-wire AC version (FEM, ): load switched directly via a thyristor in the power supply Three-wire DC version (FEM 2): load switched via a transistor and separate connection Universal version with relay output (FEM, ): load switched via a potential-free changeover contact Universal version with DPDT relay output (FEM 5, 5): load switched via potential-free changeover contact Remote switching version (FEM 7): PFM signal transmission, current pulses superimposed on the two-wire power cable FEM, 2, : between sensor and power supply FEM, 5,, 5: between sensor and power supply and load FEM 7: between sensor and power supply; in remote switching unit Nivotestor between power supply and load Height (limit value, binary) FTM 0: determined by installation point FTM : determined by sensor length (extension pipe). Approximately 2" to 55" (00 mm to 000 mm, mounted from top) FTM D: as above, except: 6" to 55" (00 mm to 000 mm) FTM with sliding sleeve: 8" to 5" (200 mm to 900 mm) FTM 2: determined by sensor cable length, 0" to 790" (800 mm to 20,000 mm, mounted from top) FTM 2 D: as above, except 0" to 790" (000 mm to 20,000 mm) Output Output signal Binary: output blocked on reaching limit Signal failure Output blocked Load (connectable) (AC, load switched via thyristor dirctly in the power supply) to FEM,FEM Transient (0 ms) max..5 A, max. 75 VA at 25 V, or max. 6 VA at 2 V (no short circuit protection). Continuous max. 87 VA at 25V, max. 8. VA at 2 V. Min. 2.5 VA at 25 V (0 ma), min. 0.5 VA at 2 V (20 ma). Voltage drop across FEM, max. 2 V. Residual current max. ma with blocked thyristor. Load (connectable) (DC, load switchedvia transistor and separate PNP connection) withfem 2 Transient ( s) max. A, max. 55 V (cyclic protection against overload and short circuiting); continuous max. 50 ma, max. 55 V; max. 0.5 µf at 55 V, max..0 µf at 2 V; residual voltage < V (with conducting transistor); residual current< 00 ma (with blocked transistor). Load (connectable) (universal current, load switched via potential-free changeover contact) with FEM, FEM I max. 6 A, V max. 25 VP max. 500 VA, cos ϕ =, P max. 750 VA, cos ϕ > 0.7I max. 6 A to 0 V, I max. 0.2 A to 25V, additional switching delay 0. s. Load (connectable) (universal current, load switched via two potential-free changeover with FEM 5, FEM 5 contacts) I max. 6 A, V max. 25 VP max. 500 VA, cos ϕ =, P max. 750 VA, cos ϕ > 0.7I max. 6 A to 0 V, I max. 0.2 A to 25V, additional switching delay 0. s. Time Delay (FEM or 2.5 seconds when covered,.5 or 7.5 seconds when or FEM 5 only) uncovered. Time delay is switch selectable. Load (connectable) (potential-free relay contact in switching unit Nivotester FTL) See withfem 7 Technical Data of the Nivotester FTL 20. Fail safe Minimum or maximum fail-safe mode, user-selectable 7
8 Technical Data (continued) Operating Conditions Orientation Any position for FTM 0, with short extension. Vertical for FTM with long extension and FTM 2 Lateral load on 600 N on narrow edge of tines, static FTM 0 fork Lateral load on 00 Nm (maximum m) FTM tube FTM 2 cable 2500 N tensile strength Operating temperature - to +58 F (-20 to + 70 C). Refer to temperature charts below. Storage temperature -0 to +85 F (-0 to + 85 C) Process material -0 to + 02 F (-0 to + 50 C). Refer to temperature charts below. temperature Operating pressure FTM 0, : -.5 to + 20 psi (- bar to +6 bar); FTM 2 D, 87 psi(6 bar); FTM 2 29 psi (2 bar) Maximum pressure Burst pressure minimum: FTM 0, = 50 psi (00 bar); FTM 2 D = 580 psi (0 bar); FTM 2 = psi ( bar) Maximum material size 9/6" ( mm) Material density Minimum.2 lb/ft (20 g/l) Climatic class Climatic protection to IEC 68, Part 2-8, Fig. 2a Ingress protection NEMA X (IP 66 to DIN 0 050) Electromagnetic By attaching the CE mark, Endress+Hauser confirms that the compatibility Soliphant FTM fulfils all legal requirements of the relevant EC directives. Interference immunity to EN (field strength 0V/m), interference emission to EN Construction Materials Process connections Power supply Display / user interface Process connection (threaded) and fork, 0 SS. Flange connections 6 SS. Extension tube, 0 SS. Cable, braided steel, 0.9" dia. (0 mm) polyurethane coated.housing (F 0), fiberglass reinforced polyester, transparent polyamide cover, EPDM seal. Housing (F 6, T ), aluminum, coated. Tapered thread -/2" x -/2 NPT to ANSI B.20.Tapered thread R -/2 to DIN 2999 Part Flanges: ANSI, DIN or JIS FEM, insert: 9 to 25 VAC, 50/60 Hz, current consumption (stand-by) maximum ma. FEM 2 insert: 0 to 55 VDC, ripple maximum.7 V, 0 to 00 Hz; current consumption maximum 5 ma, reverse polarity protection. FEM, 5 and FEM, 5 insert: 9 to 25 VAC, 6 to 60 Hz; 9 to 200 VDC; current consumption maximum 7 ma. FEM 7 insert: powered by Nivotester FTL switching unit. FEM, 2,,, : rotary switch for minimum / maximum fail-safe, red LED switching status indication.fem 7: green LED indicates forks covered. TU F ( C) 22 (50) FTM 0,0 D, 0 S,, S 76 (80) 0 (60) 0 (0) TU F ( C) 0 (60) 76 (80) 0 (0) FTM D 68 (20) -0 (-0) (20) (0) (60) (80) (00) (20) (0) - (-20) - 9 (-20) (90) TB F ( C) -0 (-0) - (-20) - (-20) 68 (20) (20) (0) (60) (80) (00) (20) (0) 9 (90) TB F ( C) Permissible ambient temperature value T U at the housing as a function of the operating temperature T B in the vessel. 8-0 (-0) -0 (-0) TU F ( C) 9 (65) - (-20) FTM 2,2 D, 2 S 76 (80) 0 (60) 0 (0) 68 (20) (20) (0) (60) (80) (00) (20) (0) 9 (90) TB F ( C)
9 Stainless steel housing Endress+Hauser offers a NEMA X rated 0 SS housing (F 8) for sanitary applications. The housing is only available for the FTM 0S, S, and 2S with FEM 7 2-wire PFM electronic insert. Refer to page for ordering information. Ø.8" (86) 5.9" (2) F8 0 Stainless Steel housing Accessories." (0).0" (02) Protective Hood Protects the Soliphant electronics housing when mounted in the field from excessive temperatures caused by direct sunlight. The hood also prevents condensation form entering the housing due to extreme temperature variations. Part # Protedtive hood for F 6 and F 0 housings. Polyamide material, 0.28 lbs (0. kg) 6." (55) Sliding sleeve, 6 Ti SS. 5 psi (0 bar) maximum pressure. Maximum operating temperature: 76 F (80 C). Threaded gland packing PTFE-fiber glass fabric. Weight: 5.7 lbs (2.6 kg).5" (max. 5) " (25) SW 75 G2.7" () DIN ISO 228 Sliding Sleeve When mounting the Soliphant FTM in a silo from the top, the sliding sleeve allows the switch point to be infinitely adjusted. NOTE: The sensor length of the FTM must be at least 5.7" (00 mm) long. Part # Cable Shortening Kit A kit is available for the Soliphant FTM 2 which consists of the accessories required to shorten the cable and make a permanent water-tight connection to the sensor. The kit is always supplied with the 00 and 20 cable versions FTM 2, FTM 2 D and FTM 2 S. The user can cut the cable to suit the application without affecting the approvals. 9
10 Ordering Information, FTM 0-2 FTM FTM - FTM 2 - D CSA dust ign., Cl II, III; div, Grps E-G, (only with aluminum housing) F FM dust ign. proof Cl II, III; Div ; Grps E-G (only with aluminum housing) AC, 2-wire, 2 to 250 V, 50/60 Hz FEM contactless 2 0 to 55 VDC, PNP -wire FEM 2 Relay SPDT, 2 to 25 VAC / 200 VDC FEM 5 Relay DPDT, 2 to 25 VAC / 200 VDC FEM 5 * Housing / Cable Entry B Housing, Aluminum coated, F6, F Housing, Polyester, F0, Housing, 0 SS, F 8 NEMA X / /2 NPT B -/2 NPT, 0 SS L -/2 ANSI 50 lb RF flange, 6 SS M 2 ANSI 50 lb RF flange, 6 SS P ANSI 50 lb RF flange, 6 SS N ANSI 50 lb RF flange, 6 SS * FM certificate consult factory D CSA dust ign., Cl II, III; div, Grps E-G F FM dust ign. proof Cl II, III, III; Div ; Grps E-G (only with aluminum housing) AC, 2-wire, 2 to 250 V, 50/60 Hz FEM contactless 2 0 to 55 VDC, PNP -wire FEM 2 Relay SPDT, 2 to 25 VAC / 200 VDC FEM 5 Relay DPDT, 2 to 25 VAC / 200 VDC FEM 5 * Housing / Cable Entry B Housing, Aluminum coated, F6, F Housing, Polyester, F0, Housing, 0 SS, F 8 NEMA X / /2 NPT B -/2 NPT, 0 SS L -/2 ANSI 50 lb RF flange, 6 SS M 2 ANSI 50 lb RF flange, 6 SS P ANSI 50 lb RF flange, 6 SS N ANSI 50 lb RF flange, 6 SS 9 Special version 6 Sensor Length (min. 2", max. 55") Price / inch probe length, 0 SS * FM certificate consult factory E CSA Cl II, div, Grp G + Coal Dust F FM dust ign. proof Cl II, III; Div ; Grps E-G (only with aluminum housing) AC, 2-wire, 2 to 250 V, 50/60 Hz FEM contactless 2 0 to 55 VDC, PNP -wire FEM 2 Relay SPDT, 2 to 25 VAC / 200 VDC FEM 5 Relay DPDT, 2 to 25 VAC / 200 VDC FEM 5 * Housing / Cable Entry B Housing, Aluminum coated, F6, F Housing, Polyester, F0, Housing, 0 SS, F 8 NEMA X / /2 NPT B -/2" NPT, 0 SS L -/2 ANSI 50 lb RF flange, 6 SS M 2 ANSI 50 lb RF flange, 6 SS P ANSI 50 lb RF flange, 6 SS N ANSI 50 lb RF flange, 6 SS 6 Sensor Length (min. 0", max. 790") 2 Price / inch cable length, 0 SS 7 Fixed length with cable shortening kit 00 8 Fixed length with cable shortening kit 20 * FM certificate consult factory Ordering Information, FTM 0 D - 2 D FTM 0 D - FTM D - FTM 2 D - G FM ex-proof, Cl I, II, III; Div ; Grps A-G K CSA Cl I, II, III; Div ; Grps A-G AC, 2-wire, 2 to 250 V, 50/60 Hz FEM contactless 2 0 to 55 VDC, PNP -wire FEM 2 Relay SPDT, 2 to 25 VAC / 200 VDC FEM 5 Relay DPDT, 2 to 25 VAC / 200 VDC FEM 5 / 5 * Housing / Cable entry K Housing, dual compartment, Aluminum coated, T,NEMA X / /" NPT B -/2" NPT, 0 SS M 2" ANSI 50 lb RF flange, 6 SS P ANSI 50 lb RF flange, 6 SS N " ANSI 50 lb RF flange, 6 SS * FM certificate consult factory G FM ex-proof, Cl I, II, III; Div ; Grps A-G M CSA Cl I, II, III; Div ; Grps A-G AC, 2-wire, 2 to 250 V, 50/60 Hz FEM contactless Relay SPDT, 2 to 25 VAC / 200 VDC FEM 5 Relay DPDT, 2 to 25 VAC / 200 VDC FEM 5 / 5 * Housing / Cable Entry K Housing, dual compartment, Aluminum coated, T,NEMA X / /" NPT B -/2" NPT, 0 SS M 2 ANSI 50 lb RF flange, 6 SS P ANSI 50 lb RF flange, 6 SS N ANSI 50 lb RF flange, 6 SS 6 Sensor Length (min 6", max 55") Price / inch probe length, 0 SS * FM certificate consult factory 0 Q FM ex-proof, Cl I, II, III; Div ; Grps C-G L CSA Cl II; Div ; Grp G + Coal Dust AC, 2-wire, 2 to 250 V, 50/60 Hz FEM contactless Relay SPDT, 2 to 25 VAC / 200 VDC FEM 5 Relay DPDT, 2 to 25 VAC / 200 VDC FEM 5 / 5 * Housing / Cable Entry K Housing, dual compartment, Aluminum coated, T,NEMA X / /" NPT B -/2" NPT, 0 SS M 2 ANSI 50 lb RF flange, 6 SS P ANSI 50 lb RF flange, 6 SS N ANSI 50 lb RF flange, 6 SS 6 Sensor Length (min 0", max 790") Price / inch cable length, 0 SS 7 Fixed length with cable shortening kit 00 8 Fixed length with cable shortening kit 20 * FM certificate consult factory
11 Ordering Information, FTM 0 S - 2 S FTM 0 S FTM S - FTM 2 S - P FM IS Cl I, II, III; Div ; Grps A-G T CSA IS CI I, II, III; Div, Grps A-G 7 Two-wire PFM signal, FEM 7 Housing / Cable Entry Housing, 0 SS, F8, NEMA X / /2 NPT B Housing, Aluminum coated, F6, F Housing, Polyester, F0, K Housing, dual compartment, Aluminum coated, T,NEMA X / /" NPT B -/2" NPT, 0 SS L -/2" ANSI 50 lb RF flange, 6 SS M 2 ANSI 50 lb RF flange, 6 SS P ANSI 50 lb RF flange, 6 SS N ANSI 50 lb RF flange, 6 SS NOTE: Dual compartment housing not available with process connection L. P FM IS Cl I, II, III; Div ; Grps A-G T CSA IS CI I, II, III; Div, Grps A-G 7 Two-wire PFM signal, FEM 7 Housing / Cable Entry Housing, 0 SS, F8, NEMA X / /2 NPT B Housing, Aluminum coated, F6, F Housing, Polyester, F0, K Housing, dual compartment, Aluminum coated, T,NEMA X / /" NPT B -/2" NPT, 0 SS L -/2" ANSI 50 lb RF flange, 6 SS M 2 ANSI 50 lb RF flange, 6 SS P ANSI 50 lb RF flange, 6 SS N ANSI 50 lb RF flange, 6 SS 6 Sensor Length (min. 2", max. 55") Price / inch probe length, 0 SS NOTE: Dual compartment housing not available with process connection L. P FM IS Cl I, II, III; Div ; Grps A-G U FM IS Cl I, II, III; Div ; Grps C-G W CSA XP CI II, Div, Grps G + coal dust 7 Two-wire PFM signal, FEM 7 Housing / Cable Entry Housing, 0 SS, F8, NEMA X / /2 NPT B Housing, Aluminum coated, F6, F Housing, Polyester, F0, K Housing, dual compartment, Aluminum coated, T,NEMA X / /" NPT B -/2" NPT, 0 SS L -/2" ANSI 50 lb RF flange, 6 SS M 2 ANSI 50 lb RF flange, 6 SS P ANSI 50 lb RF flange, 6 SS N ANSI 50 lb RF flange, 6 SS 6 Sensor Length (min. 0", max. 790") 2 Price / foot cable length, 0 SS 7 Fixed length with cable shortening kit 00 8 Fixed length with cable shortening kit 20 NOTE: Dual compartment housing not available with process connection L.
12 United States Canada Mexico Endress+Hauser, Inc. Regional Office RPS Industries 250 Endress Place Endress+Hauser, Inc. Div. of Endress+Hauser, Inc. Greenwood, IN W. Sam Houston 500 W. Central Avenue Phone: (7) Parkway North Suite A Suite C-250 Brea, CA 9282 FAX: (7) Houston, TX 770 Phone: (7) Phone: (82) FAX: (7) FAX: (82) Regional Office Endress+Hauser, Inc. Sterling IPC P.O. Box 90 Div. of Endress+Hauser, Inc. Harvey, LA Powell Road Phone: (50) Romeo, MI 8065 FAX: (50) Phone: (586) FAX: (586) Regional Office Endress+Hauser, Inc. AD Instruments 92 Town Center Div. of Endress+Hauser, Inc. New Britain, PA A Nations Crossing Road Phone: (267) Charlotte, NC Phone: (70) /856 FAX: (267) FAX: (70) Endress+Hauser Canada Ltd. 0 Graham s Lane Unit, Burlington ON, L7S W Phone: (905) FAX: (905) 68-9 Endress+Hauser Canada Ltée 6800 Côte de Liesse, Ste. 00 St. Laurent, Que HT 2A7 Téléphone: (5) Télécopieur: (5) Endress+Hauser Canada, Ltd Ave. NW #0 Edmonton, AB T5S 2L5 Phone: (780) FAX: (780) Endress+Hauser Paseo del Pedregal No. 60 Col. Jardines del Pedregal 0900, Mexico D.F. Mexico Phone: (525) FAX: (525) Endress+Hauser The Power of Know How TI 29F/2/ae/ Endress+Hauser, Inc.
Liquid Level Limit Switch liquiphant T FTL 20
Technical Information TI 64F/4/ae Liquid Level Limit Switch liquiphant T FTL 0 Level limit switch for liquids Applications The Liquiphant T FTL 0 is a level limit switch for virtually any kind of fluid
Minicap FTC260, FTC262
Technical Information Minicap FTC260, FTC262 Capacitive Limit Detection Compact switch for limit detection with active build-up compensation; No calibration necessary Version available for dust explosion
ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.
ISO-9001:2000 certified EE300 Series Electromechanical Inventory Level Measuring System Aplus Finetek Sensor, Inc. PRODUCT INTRODUCTION OPERATING PRINCIPLE The EE300 series level measuring system is a
3DLevelScanner II TECHNICAL DATA SHEET
TECHNICAL DATA SHEET Changing the market from level to volume APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
Technical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100
Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Preset Counter signo 721
Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage
DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly
DREXELBROOK A Leader In Level Measurement Solutions USonic-R Series Ultrasonic Level Measurement System User Friendly Set the measurement range directly in inches, feet, millimeters, centimeters, or meters
Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43
Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection
Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching!
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
Electronic, Digital and Mechanical Vibration Switches
PT500 Electro-Mechanical Vibration Switch Introduction The PT500 is an economical solution that provides basic vibration protection for rotating reciprocating machines. The PT500 uses an inertia sensitive
Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.
Dimensions LUC-M20 with F12 housing and process connection 2" approx. 86 65 78 Ø129 150 AF60 85 G2 2 NPT 22 ~148 Ø50 ~83 Additional dimensions see section dimensions. Features Quick and simple commissioning
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications
EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
Technical Data Sheet. 3DLevelScanner
Changing the market from level to volume Technical Data Sheet APM`s 3DLevelScanner incorporates advanced technology for accurately measuring bulk solids and powder stored in silos and open bins of all
For Multi-Parameter Meters see mvx
BULLETIN BULLETIN EM20607 VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up
AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products
Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Plastic tube flowmeters Series PT/PS
Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding
SITRANS F flowmeters SITRANS F M
Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
TEIP11 I/P signal converter for standard signals. Measurement made easy
Data Sheet 10/18-0.11-EN Rev. B TEIP11 I/P signal converter for standard signals Measurement made easy Current in air pressure Proven and reliable concept Compact design Small dimensions, low weight Sturdy
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function Document No. 155-751 SKP15U.. Description Only when assembled to Series VGU Gas valves SKP15 electro-hydraulic actuators combine with
Technical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
Liquiphant M FTL50, FTL51
Liquiphant M FTL50, FTL5 Level Limit Switch BA23F/24/ae/03.06 52005008 Liquiphant M FTL50 / FTL5 Table of Contents Safety Instructions Order Codes Installation Setup Maintenance & Cleaning Technical Data
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
Electronic Flow Switches
Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
4 Posiflow Proportional Solenoid Valves
4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,
Sanitary Type Electronic Flow Switches
Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.
Pump_PT580 Optional PT580-CFG PCM370 Optional DTM96 Buffered Dual Relay Remote Reset Local Display Condition Monitoring System PLC/DCS PT580 Digital Vibration Switch Introduction The PT580 Digital Vibration
Combi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
Flow switches Series AD/VH
Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
PRODUCT PROFILE FEATURES
PRODUCT PROFILE Pressure Transmitters & Pneumatic Transducer Airflow Transmitter, Differential Air Pressure Transmitter and Differential & Gauge Liquid/Gas Pressure Transmitter FEATURES AIRFLOW TRANSMITTER
Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor
Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
Centro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
2.12. page 223 2.12. Products for Explosion hazardous Environment
2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available
Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
Control Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****
Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H***** FM 3046039 Class I Div 1, Groups A, B, C and D Class II Div 1, Groups E, F and G; Class III Class I, Zone 0, AEx ia IIC Ga, Ga/Gb, Gb Document ID:
How To Use A Ds340 (Dsp)
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
Laser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option
REGISTRATION MARK SENSORS MARK EYE PRO 2 Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option Registration Mark Photoelectric Sensors 2-115 High-Resolution Registration
Scraper Passage Indicator. Electrical Indicator. Features
IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage
Heating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
Contactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
Pressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
Temperature Switch Thermophant T TTR 31, TTR 35
Technical Information Temperature Switch Thermophant T TTR 3, TTR 35 Temperature switch for the safe measurement, monitoring and control of process temperatures Application Temperature switch for the monitoring,
Digital Pressure Measuring Instrument MDR480
Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,
Universal Voltage Terminal Photoelectric E3JM
Universal Voltage Terminal Photoelectric Universal AC/DC Photoelectric Sensor with Built-in Timer Easy-to-wire terminal block Built-in timer offers selectable ON-delay, OFF-delay and one-shot Relay or
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
Relative pressure transmitter type 520
Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the
Color Mark Sensor with Red or Green LED E3S-VS
Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
In-Line Electronic Flow Switches
In-Line Electronic Flow Switches Industries Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
Instruction Manual. T3111 T3111L T3111P T3111Ex
www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs
Capacitive Prox E2K-X
Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows
Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau
KA 180F/00/en/06.01 (a) 52010984 Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau Safety instructions The FTS 20 floating switch may only be used as a level limit switch
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
Analog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
Solid-State Timer H3G
ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : [email protected] Solid-State Timer Low-Cost, Plug-In
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)
CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz) DESCRIPTION The Radar Level Meters of BM COMPACT WAVE 6.3 GHz series are excellent devices for no contact level measurement. The microwave impulses, emitted
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370
Pump_TM016 Pump Local Display TM0200 TM0200 4-20mA PLC/DCS Case 1 Pump Relay Output Module 4-20mA Optional PT371 Modbus PT373 Case 2 PCM370 TM016 Velocity/ Acceleration Vibration Transmitter Introduction