MIDCS Window Treatment General Specifications Marriott International
|
|
|
- Ashlee Stewart
- 9 years ago
- Views:
Transcription
1 MIDCS Window Treatment General Specifications Marriott International The following are the specifications for window treatments used by Marriott International. Any deviation, modification or other changes must be discussed with the appropriate purchasing agent verbally and confirmed in writing with documents and pictures clearly showing all changes and locations on the items. All window treatment items must meet or exceed the specifications contained within this document. All Marriott International window treatment or related window treatment products fabricators are responsible for the design and functional performance of any window treatment product they provide. If a design allows for light leakage, it shall be called to the purchasing agent s attention. Each fabricator is responsible for providing review samples as needed. All fabricators are responsible for always obtaining approval from the appropriate purchasing agent prior to starting production. Fabrics, General All fabrics used in window treatment MUST meet the codes in the next section. (The fabricator is not responsible for these codes if the fabric is COM). If defects are found which will affect production, the purchasing agent shall be contacted immediately so that disposition of the defective fabric may be worked out. Fabrics, Codes Abrasion Resistance, All Decorative Fabrics: Wyzenbeek: ASTM D ; 20,000 double rubs back and forth motion, #10 Duck; Martindale, 25,000 double rubs, ASTM D ; 12 KPa pressure; Circular Motion, #10 Duck; (Although there are no abrasion standards for sheers, they should be constructed sufficiently to prevent yarn separation during commercial use). Flammability, Window Treatment: All items, including drapes, sheers, fabric valances, swags, jabots, or any other window treatment: NFPA , Test Method 1 (Vinyl coated blackout, Test Method 2) and BFD1X-1 Boston, in addition to local jurisdictional requirements. (Custom one-off window projects do not need BFDIX-1 if NOT used within the city limits of Boston). This treatment MUST be inherent, not topical. All BFDIX-1 items require a permit from the Boston Fire Department: To get Boston Permits, go to Permits and Applications section. Colorfastness to Light AATCC 16 Option 1 or : Drapery fabrics: 60 Hours, Grade 4. Wet and Dry Crocking, All Fabrics, 4.0 Dry, 3.5 Wet AATCC 8-200: (Except prints: AATCC ). Tensile Strength. Fabrics ASTM D (2001) (Grab Test): 25 lbs. for over 6 Ounce/yd. squared Drapery & 15 lbs. for less than 6 Ounce. Fabrics & Black Out - No PBDE s (Polybromide Diphenyl Ethers) shall be used and formaldehyde content shall be below the allowable threshold limit. Performance All draperies, hardware and installation shall be provided in accordance with the specifications contained herein and shall not have deviations other than orders written and issued by the purchasing agent. WT-001 Rev 0 47
2 WINDOW TREATMENT GENERAL SPECIFICATIONS Measurement and Project Quotation The fabricator is responsible for taking measurements at the job sites and for dimension accuracy in their quotations. The fabricator shall make no variations, additions, or deletions to the contract issued by the purchasing agent without a confirmed addendum. Tentative start dates shall be provided by the purchasing agent at the time the quotation is requested. It is the responsibility of the contractor to call the purchasing agent periodically to insure the install date has not changed. The fabricator shall be responsible for forwarding quotations to the purchasing agent within six (6) weeks of the installation start dates for new builds and within eight (8) weeks for renovations. Hardware and parts shall be itemized, priced and listed separately. Material & Services Provided by Fabricator Unless other provisions are made, the fabricator shall: o Provide all raw materials except COM drape/sheer fabrics and blackout. o Provide proper storage for all fabrics, materials and equipment. o Maintain a current inventory & report it to the purchasing agent monthly. o Provide the purchasing agent with scaled sections of any non-prototypical (custom) window treatment before fabrication is begun. o Advise the purchasing agent immediately when it is known that rooms will not be available on dates installs are schedule. o Advise the purchasing agent immediately when issues arise that may affect install schedules or overall quality. o Ensure that all install staff is neatly attired with the fabricator s name prominently displayed so as to be quickly identified. o Furnish supervision and installers acceptable to the purchasing agent s representative on the job site. o Supply all labor, transportation equipment, appliances, and service necessary to furnish completed window treatment. o Make all necessary adjustments in the Work as may be required to render the Work in proper condition suitable for final acceptance. o Notify the purchasing agent if steaming is required as soon as it is known to determine if the project has the additional funds to cover the steaming costs. o Remove all generated trash daily from the job site. o Ensure that all fabrication and installation sub-contractors return to the job and make any needed adjustments, repairs, lengthening or shortening as may be considered necessary by the purchasing agent. o Assume all costs stemming from defects caused by the fabricator, including the replacement of fabrics due to poor workmanship, shrinkage (pertaining to hems) due to improper styling or size as specified herein. o Show proof of performance and delivery as required. If requested, fittings and supplies such as buckram, weights, thread, and samples shall be submitted to the purchasing agent for approval before fabrication has started. Applicable to all Fabrication All drapes and sheers shall be made with the required widths of fabric specified and never shall less than one-half of a width be used in any panel. All ceiling-to-floor draperies and sheers shall fall to WT-001 Rev 0 48
3 WINDOW TREATMENT GENERAL SPECIFICATIONS ¾ to 1 from the carpet or any finished floor surface, unless otherwise noted on the drawings. All ceiling-to-ptac, bench or other surface elevated from the floor surface treatments shall fall to ½ from the top of the elevated surface unless otherwise specified. All selvages shall be removed, patterns shall be matched; drapes and sheers shall be made to exact size. All corners on the bottom hem shall be mitred. Face fabric hems shall be blind-stitched. The thread shall be poly-cotton and color matched. If center-close, the overlaps shall be 3 ½ with the buckram double folded back. The returns shall be 3 to 6 depending on the application with the double fold back of the return. If specified, all slant tops shall follow the angle of the window and all pleats shall be upright. All bottom hems shall be level. All seams shall be overlock stitched (serged) with safety stitches, and all seams shall be hidden at the side of the pleat, or back of the ripple fold, using poly/cotton neutral-color thread, unless otherwise specified. The side hems shall be 1 ½, blind stitched and double folded using poly/cotton thread. If the drapes are not wall-to-wall, the fabrication is to ensure that the returns reach the walls the drapes cover. Drapes Fabrication Applicable to all pinch pleat drapes: o Headings shall be 4 and double folded with permanent finished buckram, double-back folds at the overlaps and returns and sewn closures using poly/cotton thread. o Unless otherwise specified, drapes shall be 200% fullness (fabric used is twice the width of the finished drape) Exception: Public space and suites should use 250% to 300% fullness. (NOTE: Fullness varies by brand and property. If the properties do not adhere to prototypical designs, please consult with the purchasing agent or design firm. If the fullness is not specified, consult with the purchasing agent or design firm). o Stationary side panel pleats shall be tacked down with matching thread and the fullness shall be 200%. The hem shall be the standard double 4. o If triple fold French pleats are specified, they shall be machine sewn with 14 thread bar, L tacked or F tacked 1/2 inch up from the bottom of the buckram, using poly/cotton thread. Applicable to all ripple fold drapes: o The fullness range shall be 60%, 80%, 100% or 120% as specified per project. Lined drapes: o The buckram shall be inserted between the face fabric and the lining and stitched across the top. On overlaps and returns, double fold the buckram back by 12. o The lining shall extend to the top of the finished drapery (Pillow case top), and all the way to the sides. o The lining fabric shall be 2 straight single needle lockstitched with a single turn-up above face fabric using poly/cotton thread. o The bottom hem of the face fabric shall be double folded by 4 using straight single-needle lock stitches, with poly/cotton thread. The side hems shall be 1 ½ and blind stitched with the lining extending to the edge of the drapery using poly/cotton thread. o 1 covered lead weights shall be tacked into the hemline on each seam and corner of the face fabric. It is not required in the lining. Sheers Fabrication Applicable to all sheers: WT-001 Rev 0 49
4 WINDOW TREATMENT GENERAL SPECIFICATIONS o Unless otherwise specified, the fullness shall be 250% to 300%, except for ripple fold. (NOTE: Fullness varies by brand and property. If the property does not adhere to prototypical designs, please consult with the purchasing agent or design firm. If the fullness is not specified, consult with the purchasing agent or design firm). o The bottom hems shall be 4, double folded and sewn using straight single needle lockstitches with poly/cotton thread. Lobbies and suites bottom hems shall be blindstitched. Hanky hems may be specified. (Bottom weight serged in the hem) o The side hems shall be 1 ½, blind stitched and double folded using poly/cotton thread. o Kirsch or Kirsch style weighted tape shall be used the entire length of the bottom hems at or near the bottom. o The overlaps shall be 3 ½ with double fold back of the buckram. o The returns shall be 3 inches with double fold back of the buckram. Applicable to all ripple fold sheers: o The fullness range shall be 120%, or as specified per project. Pinch pleat: o Headings shall be 4 and double folded with permanent finished buckram, double-back folds at the overlaps and returns and sewn closures using poly/cotton thread. o If triple-fold French pleats are selected, they shall be machine sewn with 14 thread bar or L tacked 1/2 inch up from the bottom of the buckram, using poly/cotton thread. Blackout The seams joining the blackout shall be ½ Z type. Fabrication shall be done so that pin holes are minimized. If the blackout is 2-color, the side facing the room shall be specified by the purchasing agent and verified by the fabricator. Cornice Fabrication and Installation The fabricator shall construct and install cornices as follows, unless otherwise specified: o 1/2 particleboard shall be used. Plywood is not authorized. o 5 ounce fill or padding, flame retardant shall be used. o 1 by 2 inch header board shall be used. o Self cord welt top, bottom and sides shall be used. o The lining shall be blind tacked with tackless stripping on the bottom to hide the staples. o Stainless steel staples shall be used. o All cornice installations shall use L brackets on the walls and Z brackets on ceilings. o A full width of fabric shall be centered on the cornice with seams equidistant from each end. o If the cornices are not self lined, the fabricator shall ensure that the lining fabric has an FR rating suitable to the jurisdiction in which it is installed. Hardware All hardware shall be of commercial quality and workmanship and shall be Kirsch or Kirsch style. The following are specific area requirements that shall be followed: All hardware shall be commercial grade. Tracks shall be extruded aluminum only. All metal components, including but not limited to master carriers, ball bearings, baton screws and baton key rings shall be stainless steel. Fiberglass batons shall be used and shall be rounded at both ends. ADA batons shall have their bottom ends hanging 48 off the floor. (Note: ADA batons MAY be acrylic if fiberglass is not available). WT-001 Rev 0 50
5 WINDOW TREATMENT GENERAL SPECIFICATIONS Acrylic batons are never appropriate except for ADA applications. All hooks shall be stainless steel and Kirsch or Kirsch quality. All masters shall be wheeled and there shall be 6 to 8 included. Hanging Finished Window Treatment All window treatments shall be mounted so that they do not separate from the wall or ceiling. All drapes and sheers shall be hung so that they drape properly (When viewed from the top, the fabric drapes in a continuous S pattern). Check buckram and break it if needed to insure S folds start at the buckram and flow to the floor. All pinch pleat draperies shall be pinned and hung evenly with appropriate pin-on hooks except for draperies over 12 feet long. They shall be hung using sew-on hooks. Angle brackets shall be attached to the wall with a screw to attach the return. Tenter hooks shall not be used. If needed in instances where the draperies end at doorways, the fabricator shall install a Lucite cuff mounted against mullion and lined up with the doorknob. (The cuff shall be supplied by the fabricator as part of the original quote and shall be billed to the purchasing agent. In cases where it is not part of the quote, it is shall be billed as a separate item). All sheers shall be hung so that they are not visible at any edge when the drapes are in their closed position. WT-001 Rev 0 51
6 Vendor List
7 Transformations Public Space & Facets Guestroom New Build Vendor List ABSOCOLD CORP AC FURNITURE CO, INC AMTREND CORPORATION AQUA HOSPITALITY ARCHITECTURAL SUPPLEMENTS LLC ARTISTIC FRAMING INC ASHLEY LIGHTING INC BRG PRECISION PRODUCTS BRINTONS US AXMINSTER BROWN JORDAN COMPANY INC CARSONS INC CHALLENGER LIGHTING D'STYLE INC DELTROPICO DESIGNS LLC EYKON WALL SOURCE FAIRMONT DESIGNS HOSPITALITY GROUP INC FALCON FARMBOY FINE ARTS & DESIGN CANADA FLOS INC FORBES INDUSTRIES INC GLOBAL VIEWS GOLD LEAF DESIGN GROUP GRAINGER INC J G EDELEN CO INC JAMISON BEDDING INC JDT INTERNATIONAL LLC JL FURNISHINGS LLC KARTRI SALES CO INC KICHLER LIGHTING KIMBALL LODGING GROUP LEGGETT & PLATT INC LG ELECTRONICS USA INC LIFE FITNESS LODGING BY LIBERTY INC MAJESTIC MIRROR & FRAME INC MDC WALLCOVERINGS MILTON A BLEIER COMPANY MTS SEATING INC OFS P KAUFMANN CONTRACT PEERLESS INDUSTRIES INC PERMANENT FOLIAGE INC PLANTSCAPING INC QUOIZEL INC ROCKLAND INDUSTRIES INC SCOTT LAMP CO INC SEALY MATTRESS COMPANY SERTA MATTRESS CO SHAW INDUSTRIES INC SHELBY WILLIAMS INDUSTRIES INC SIMMONS BEDDING SK TEXTILE INC SOUTHERN ALUMINUM MANUFACTURING INC SPONGE CUSHION INC TAI PING CARPETS INC TECHNICAL CONSUMER PRODUCTS INC THE UTTERMOST CO TREND LIGHTING CORP INC TRINITY LIGHTING INC UNILIGHT LIMITED CANADA US BUSINESS INTERIORS VALLEY FORGE TEXTILES VAN TEAL INC VIRGINIA QUILTING INC
8 Window Treatment Elevations and Specifications
9
10
11
12
13
14 COURTYARD BY MARRIOTT Public Space Interior Decor Package: TRANSFORMATIONS PUBLIC SPACE WINDOW COVERING SPECIFICATIONS Sheer Fabric (Lobby, Meeting Room and Public Board Room) Valley Forge Textiles Citrus Sheer 2 # 616-DMM Marriott Material ID # wide 100% polyester Fabric is directional. Railroad whenever possible, though entire Public Space must be uniform in direction Blackout Lining (Meeting Room and Public Board Room) Roc-Lon Denimtone Color: Mustard BO Marriott Material ID # wide 100% polyester Fabric is non-directional White side to the window LOBBY SHEERS ONLY Standard Fabrication Details Ripplefold Hanky hem with string weight Cord-operated traverse rods are not preferred 3 high drapery pocket in ceiling where possible to conceal hardware and top hem (New Construction) Hardware is Forest Group USA #CM-512 or equal, mounted tight to ceiling. Wall-mounted brackets are not acceptable. Drapery shall run floor-to-ceiling wherever possible, and create one consistent, horizontal line. Drapery behind Media Pods, where clearances may be tight, may stop at raised sill to save space. Center draw typical. Smaller windows may have side draw to reduce panels and batons. Drapery shall draw and frame the view beyond, not clutter the view beyond. Wide expanses of glass may require intermediate pairs of drapery. Ceiling height up to 11-0 AFF 120% Fullness Fully-operable White batons to a 6-0 maximum length Maximum height to the bottom of a baton is 5-0 AFF Maximum height of manually-operated sheers is of 3 3/4/2009
15 Ceiling Heights of more than 11-0 AFF (Fabric cannot be railroaded) Stationary side hangings 120% fullness Hardware installed only where drapery hangs. Rods do not need to be continuous across entire length of window. If continuous rods are used, mechanical stops shall be installed to limit drapery traverse. To frame the views beyond, side hangings shall project both into window frame to cover the edge of glass, and beyond window frame to cover a portion of the adjacent wall area. Projections each side should be proportional to the span of glass, and wall area on each side. Additional light control, if required, shall be achieved on a property-by-property basis using tinted window film MEETING ROOM & PUBLIC BOARD ROOM SHEERS WITH BLACKOUT LINING Sheer Fabrication Details 120% fullness Hanky hem with string weight Drapery shall run floor-to-ceiling where ever possible, and create one consistent, horizontal line. 3 high drapery pocket in ceiling where possible to conceal hardware and top hem (New Construction) Fully-operable Cord-operated traverse rods are not preferred Hardware to be mounted tight to ceiling. Wall Brackets are not acceptable. White batons to a 6-0 maximum length Maximum height to the bottom of a baton is 5-0 AFF Maximum height of manually-operated sheers is 11-0 Blackout drapery hung behind sheers. No over drapery. Remove any valance or cornice and do not replace Blackout Fabrication Details 120% fullness 1/2" double-fold, clean finish hem A plastic covered 1 x1 weight secured in the each corner. French seams at panel seams Meeting Room and Public Board Room fire egress doors and associated exit signage shall not, nor have the potential to be covered by drapery. If light control is required, the use of a blackout film applied to the glass portion of a door and side light is preferred, and achieved on a property-by-property basis. The film shall coordinate with the décor of the room, and color of the adjacent door frame. 2 of 3 3/4/2009
16 EXERCISE ROOM (OPTIONAL) GUEST CORRIDOR (OPTIONAL) EMPLOYEE DINING ADMINISTRATIVE OFFICES STAIRWELLS MAINTENANCE OFFICE HOUSEKEEPING MANAGER BACK OF HOUSE VENDING Roller Shade Hunter Douglas Hospitality Pattern: Haze Openness: 10% Color: Courtyard Crystal Fire-rated Standard Roll 3 Coordinating White Fascia Inside-mount Heat-sealed hem bar Continuous loop, metal beaded chain with cord tensioner 3 of 3 3/4/2009
17
18
19
20
HOw TO specify Drapery
How to specify Drapery Table of Contents Introduction... 3 Questions to Get You Started... 5 Fabric Choices... 6 Drapery Anatomy... 8 Drapery Terminology... 9 Select Your Drapery Header... 10 Define Your
Rowley project list: Contemporary Layered Ripplefold Window Treatment
Rowley project list: Contemporary Layered Ripplefold Window Treatment Ripplefold panels are gaining popularity in the residential market. This style of panel takes less fabric length than a traditional
HOW TO MEASURE FOR DRAPERY & WINDOW
HOW TO MEASURE FOR DRAPERY & WINDOW From the fabric you select to the hardware that you choose, window treatments are an opportunity to define a room s style. This guide outlines the various drapery styles
Kids Woven - Minimum Construction Standards
Kids Woven - Minimum Construction Standards NOTE All construction standards will be followed except when specified otherwise Must use Bon-Ton approved suppliers Vendor must meet all applicable Bon-Ton
CLEAR-DIVISIONS CENTERFOLD
CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in
CLEAR-DIVISIONS APERTO
CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the
RIPPLEFOLD DRAPERY SYSTEM FABRICATION GUIDE updated July 2008
DRAPERY SYSTEM FABRICATION GUIDE updated July 2008 WWW. KIRSCH. COM RIPPLEFOLD DRAPERY SYSTEM Uniformly Beautiful, Inside and Out Soft, ripple-like folds flow smoothly from one end of the track to the
Basic Spring Motor Roller Shades
Comprehensive Roller Shade Installation Guide Basic Spring Motor Roller Shades ATTENTION!!! READ CAREFULLY! This shade has a reliable long-lasting Spring Motor. The Spring Motor must have proper tension
CLEAR-DIVISIONS VARIOFOLD
CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the
glass & Glazing Products
glass & Glazing Products WallMaker Create an unlimited variety of bright, beautiful and secure interior environments with the easy-to-install Stylmark WallMaker glass wall system. This versatile system
Housing Fact Sheets. Energy Saving Window Treatments
Housing Fact Sheets Energy Saving Window Treatments Windows are a major source of heat loss but they are necessary for light, ventilation, and view. In a typical single family home, about 20% of the heat
SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
Architect s Guide. A RCHI T ECT S G UIDE WI NDOW H A RDWA RE September 2008
A RCHI T ECT S G UIDE WI NDOW H A RDWA RE September 008 Architect s Guide W I N D O W H A R D W A R E Kirsch, the most widely specified window hardware brand, offers a complete selection of window hardware
Sun Windows General Information Sun New Construction Window Installation Instructions
Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten
TENSION ISSUES? ROLLER SEE PAGE 7
ROLLER TENSION ISSUES? SEE PAGE 7 Roller Shade Installation Guide Important: If you have ordered a valance for your shade, you must first read the Valance Installation Guide found in your box. We make
By SP Partners, LLC. www.rainbowatticstair.com INSTALLATION GUIDE. Prestige
By SP Partners, LLC www.rainbowatticstair.com INSTALLATION GUIDE Prestige IMPORTANT READ THIS FIRST Inspect stair for any damage prior to installation. Stair is NOT to be installed while home is under
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
Wren Kitchens Installation Tips... 3. Carefully check your kitchen delivery... 4. Measuring out and marking up... 5. Fitting the base cabinets...
tra 1 Index Wren Kitchens Installation Tips... 3 Carefully check your kitchen delivery... 4 Measuring out and marking up... 5 Fitting the base cabinets... 6 Fitting the corner cabinets... 7 The 972mm or
Preformed Metal Roofing and Siding
Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision
Time for Tea Collection
Time for Tea Collection F70264 Time for Tea Collection Project Instructions Apron Luncheon Mats & Napkins Coaster Drip Catcher Tea Cozy Click on Photo for Project Instructions Frame & Fabric Mat Tea Pot
GUIDELINES FOR REHABILITATION OF TRADITIONAL COMMERCIAL BUILDINGS DESIGN GUIDELINES
GUIDELINES FOR REHABILITATION OF TRADITIONAL COMMERCIAL BUILDINGS DESIGN GUIDELINES PAGE 13 DESIGN GUIDELINES The following design guidelines have been developed to guide appropriate design in the Downtown
Calvert USA, Inc. Attic Stairs
Calvert USA, Inc. Attic Stairs Instructions for installation of vertical opening access stairs Model numbers: 7035 through 7047 Calvert USA, Inc., P.O. Box 841, Solomons, MD 20688, Tel. (410) 286-1430,
MEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST
OPTIONAL INFORMATION Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: MEANS OF EXIT / ESCAPE / EGRESS Guidelines: This checklist covers some of the regulations
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin
Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin americancraftsmanwindows.com Project Requirements: Failure to follow these instructions may void product
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
Automatic Door Selection Guide
Automatic Door Selection Guide AAADM 1300 Sumner Avenue Cleveland, OH 44115 P: 216-241-7333 F: 216-241-0105 [email protected] Automatic Door Selection Guide General: The members of AAADM manufacture an assortment
INSTRUCTION BOOK FOR. Lace And Grommet Theater-Type Screens
INSTRUCTION BOOK FOR Lace And Grommet Theater-Type Screens Pre-Installation Da-Lite Lace and Grommet screens are custom made to meet the requirements for large surface installation of a relatively permanent
Tundra Series Windows January 2016
Tundra Series Windows January 2016 New Construction Installation Instructions Nail Fin, J-Fin and Brickmold Aplications product. ATTENTION! Read and understand all installation instructions before installing
DE Frame with C Series Sidelight
TOOLS REQUIRED Tape measure 6' magnetic level 3' magnetic level Screw gun with clutch adjusted #2 phillips tip #3 phillips tip Screwdriver (used to adjust frame on will using oval slots) Pry Bar Powder
ATTACHMENT A STRUCTURAL INTERIOR DESIGN (SID) REQUIREMENTS
ATTACHMENT A STRUCTURAL INTERIOR DESIGN (SID) REQUIREMENTS 1.0 GENERAL INFORMATION Structural Interior Design includes all building related elements and components generally part of the building itself,
CordlessPleated FabricShade including Top-Down/Bottom-Up. owner's handbook
CordlessPleated FabricShade including Top-Down/Bottom-Up owner's handbook July, 2013 español página 9 2 INSTALLATION INSTRUCTIONS Step 1. Check Package Contents Missing part? Call 1-800-264-1190 Mounting
An introduction to selling blinds
An introduction to selling blinds We are a small family owned independent blind manufacturer. We have been manufacturing blinds for trade and contract customers since 1991, from our factory in Hevingham
PRO PANELS. 1-800-525-4159 www.propanels.com. the artist s choice in display designed by artists, for artists. voice: 214-350-5765 fax: 214-350-7372
PRO PANELS by MD Enterprises the artist s choice in display designed by artists, for artists 1-800-525-4159 www.propanels.com voice: 214-350-5765 fax: 214-350-7372 MD Enterprises 1-800-525-4159 voice:
BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.
BOQ SPECIFICATIONS VERTICAL BLINDS Vertical Blinds made of glass fibre fabrics in width 5 (or 4 ). Minimum overlapping of ¾ in fabric. Top aluminium anodized rail of 1.4 mm thickness. 2 inch wide channel
Bafl-Sorb Sound Absorbing Ceiling Baffles
Bafl-Sorb Sound Absorbing Ceiling Baffles INC offers a complete line of Sound Absorbing Ceiling Baffles to compliment any environment. Our ceiling baffles are among the most cost-effective method of adding
TEST REPORT. Report No.: B3404.01-801-47. Rendered to: CROFT, LLC. Magnolia, Mississippi. PRODUCT TYPE: Aluminum Single Hung Window SERIES/MODEL: 95
Architectural Testing TEST REPORT Report No.: B3404.01-801-47 Rendered to: CROFT, LLC. Magnolia, Mississippi PRODUCT TYPE: Aluminum Single Hung Window SERIES/MODEL: 95 SPECIFICATION: AAMA/WDMA/CSA 101/I.S.2/A440-08,
Customer Service 800.780.8889 or visit us online at smithnoble.com. Wood Shutters. Step by Step Installation. Troubleshooting Tips
reflect your style TM Customer Service 800.780.8889 or visit us online at smithnoble.com Wood Shutters Step by Step Installation Troubleshooting Tips Easy Care Instructions STEP 1 Your New Shutter Thank
HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES
HOLLOW METAL MANUAL NAAMM STANDARD HMMA 810-87 8d METAL DOORS & FRAMES NAAMM 2 87 HOLLOW METAL HOLLOW METAL DOORS FOURTH EDITION NAAMM 2 87 8d METAL DOORS & FRAMES A Division of NATIONAL ASSOCIATION OF
MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY. State Fire Marshal
MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY Policy #: Subject of Policy: INS-04 (2007) Escape Windows Revised and Approved By: Title: Jerry Rosendahl State Fire
149mm. Walk-Thru Assembly Gate. MODEL NO: 1161, 1167 Owner s Manual. www.regalo-baby.com
149mm 210mm Walk-Thru Assembly Gate MODEL NO: 1161, 1167 Owner s Manual READ ALL INSTRUCTIONS BEFORE ASSEMBLY AND USE OF GATE. KEEP INSTRUCTIONS FOR FUTURE USE. www.regalo-baby.com... Regalo International,
INC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications
INC Flexi-Sorb Noise Control Curtain System Versatile Flexible Easy To Install Durable Good Noise Reduction Economical Our Flexi-Sorb noise control curtain product line consists of flexible, durable acoustical
PUBLIC RESTROOMS, DESIGN INTENT
PUBLIC RESTROOMS, DESIGN INTENT 1.01 STRUCTURAL A. Where feasible, metal stud partitions will be constructed on a 6 high concrete curb. 1.02 MECHANICAL A. Restrooms will have a minimum of 15 air changes
PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY
PERFORMANCE TEST REPORT Rendered to: GLASSCRAFT DOOR COMPANY SERIES/MODEL: Buffalo Forge Steel Doors / Round Top Single PRODUCT TYPE: In-swing Round Top Single Door RH-4 Title Uniform Load Deflection Test
How To Work With Beads. By Rowan
R O W A N How To Work With Beads By Rowan HOW TO WORK WITH BEADS Adding beads to a knitted or crocheted design gives it a really special touch especially when the beads added are as stunning as those in
How To Fit A Portman Door Leaf
Portman Sliding Door Gear Timber/Frames Doors Frameless Glass Doors Top track Portman top tracks are suitable for door leaves of up to 80kg as standard Material is 6063T6 aluminium alloy anodised to 15
A. The shade structure contractor shall be responsible for the design, engineering, fabrication, and supply of the work specified herein.
13310 FABRIC SHADE STRUCTURES FOR PLAYGROUND AREAS ************************************************************************************************************************ SPECIFIER: CSI Master Format
TABLE OF CONTENTS INTERIOR BANNER DISPLAYS 2-4 LIGHT BOX DISPLAYS 5 EXTERIOR SIGN DISPLAYS 6 HARDWARE 7-9
DISPLAY CATALOG TABLE OF CONTENTS 2-4 LIGHT BOX DISPLAYS 5 EXTERIOR SIGN DISPLAYS 6 7-9 Whether you need a small yard sign or an oversized banner display, look to Signs and Graphics by FedEx Office to
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions
Retractable Screen. Replacement Screen Instructions
Retractable Screen Patent Pending Replacement Screen Instructions For RTS, RET, & RTM Products ATTENTION! Retractable screens are not intended to provide security or provide for the retention of objects,
LONDON JUBILEE AND OLYMPIC CELEBRATION ITEMS BY HILARY GOODING FOR MAKOWER UK
LONDON JUBILEE AND OLYMPIC CELEBRATION ITEMS BY HILARY GOODING FOR MAKOWER UK 118 Grey s Road, Henley on Thames, Oxon RG9 1QW www.makoweruk.com Email: [email protected] www.andoverfabrics.com LONDON Designed
HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL
HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL Please read these instructions carefully and completely before attempting to install Hale Pet Doors; they will guide you through the steps
Residential Garage Door Terminology
A Air Infiltration: The leakage or passage of air through a door system Anodize: A hard non-corrosive oxide film on the surface of aluminum Astragal: A compressible or deformable seal provided on the bottom
PANELIZED HOME INSTALLATION GUIDELINE
PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.
Black Wolf POCKET BILLIARD TABLE INSTALLATION MANUAL. SERVICE DEPARTMENT P.O. BOX 68 BRISTOL, WI 53104
Black Wolf TM POCKET BILLIARD TABLE INSTALLATION MANUAL www.brunswickbilliards.com SERVICE DEPARTMENT P.O. BOX 68 BRISTOL, WI 53104 51-905710-000 SEPTEMBER 2010 NOTE: Please use the instructions in this
Brick Veneer Construction
Brick Veneer Construction Check list of suggested tools & support items Claw hammer Tape measure 3/4" [19 or 20] Wood chisel Wood or plastic shims Pry bar Utility knife Caulking and caulking gun Power
BUILD A TABLETOP LOOM
BUILD A TABLETOP LOOM From 1" x 2" stock (actual 3/4" x 1"1/2) cut: 4 pieces 15" long 4 pieces 5"1/2 long Use the above to make 2 frames for the front and back of the loom. From 1" x 4" stock (actual 3/4"
INSTALLATION INSTRUCTIONS for Premium Pocket Windows (JII022) IMPoRtaNt INFoRMatIoN & glossary. safety & HaNdlINg
Thank you for selecting JeLd-weN products. Attached are JeLd-weN s recommended installation instructions for pocket (replacement) double-hung, casement, awning, picture or transom windows, designed to
5-8.1.4* Any required illumination shall be arranged so that the failure of any single lighting unit shall not leave any area in darkness.
NFPA 101 Life Safety Code Section 5-8 Illumination of Means of Egress 5-8.1 General. 5-8.1* Illumination of means of egress shall be provided in accordance with this section for every building and structure
General Fire Code Requirements Within Commercial Tenant Spaces
FIRE DEPARTMENT in cooperation with Scope: General Fire Code Requirements Within Commercial Tenant Spaces This handout is designed to assist owners, architects, contractors and others in understanding
WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST
0 RIVERSIDE DRIVE, OTTAWA, ON A0.0 COVER SHEET / DRAWING LIST A0. LEGEND AND GENERAL NOTES A0. GENERAL NOTES A0. GENERAL NOTES A0. TYPICAL WASHROOM WALL/SINK SECTION A0. DETAIL - CONTROL JOINT A0. DETAIL
How To Test For An Architectural Test
Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Rendered to: CORAL ARCHITECTURAL PRODUCTS SERIES/MODEL: PW 256 with Door Openings PRODUCT TYPE: Aluminum Impact Resistant Curtain Wall System
AMERICAN GOTHIC PLAYHOUSE
AMERICAN GOTHIC PLAYHOUSE Project Plan #856 Sheet 1 of 5 Pick a spot and get started with the beautiful that your kids will love. The design of the playhouse includes 35 square feet of interior space plus
SECTION 6. Glass Storefront Doors:
SECTION 6 Glass Storefront Doors: Table of Contents 3070 Storefront Door System Description & Dimensions 6070 Storefront Door System Description & Dimensions Door Leaf Detail Optional 10 Bottom Rail Detail
Speed-Mat Rectangle Cutter
Speed-Mat Rectangle Cutter 1 Honeycomb baseboard. 2 Left hold down. 14 3 Bottom hold down. 4 4 Left / right rule. 8 5 8 5 Left / right rule pointer. 1 6 Top / bottom rule. 7 Top / bottom rule pointer.
-1- SPECIFICATIONS 002085 CONE SETTER PLATFORM ATTACHMENT INDEX
-1-002085 CONE SETTER PLATFORM ATTACHMENT INDEX I. GENERAL EQUIPMENT : A. Intent Statement B. Cone Setter Platform II. III. 1. Understructure Frame 2. Mounting Components 3. Paint 4. Basket 5. Labels 6.
Premier & Deluxe 3-Season Room Sliding Glass Door
DTSSGD-11 Premier & Deluxe 3-Season Room Sliding Glass Door Installation Instructions Screen Door Seal Left Side Track Top Track Assembly Right Side Track Right Side Trim Sliding Glass Door Sliding Screen
WINDOW AND DOOR REPLACEMENT REQUIREMENTS
WINDOW AND DOOR REPLACEMENT REQUIREMENTS Should you have any questions after reading the following information, please call the Building Inspection Department at 651-439-4439 to discuss the topics of concern.
SEWING MAINTENANCE CHECKLIST
SEWING MAINTENANCE CHECKLIST Many Retail, Brand-name Marketing, Mail Order and Sourcing Companies are visiting existing and potential Contractor sewing facilities and evaluating their sewing capabilities
DIY CABINET REFACING INSTALLATION GUIDE
DIY CABINET REFACING INSTALLATION GUIDE CABINET REFACING INSTALLATION Are you ready to reface your outdated cabinets? This guide will show you how to install your new Facelifters Cabinet Refacing Products
Destiny Shower Enclosure Installation Instructions
Destiny Shower Enclosure Installation Instructions IMPORTANT Please read carefully the following instructions before installing your shower enclosure. If you have any questions on this shower enclosure
FF+E Package 1: Casegoods Specifications UCSD NORTH CAMPUS HOUSING, PHASE 1
FF+E Package 1: Casegoods Specifications UCSD NORTH CAMPUS HOUSING, PHASE 1 Issue Date: 3/3/2009 Each furniture item scheduled in this specification manual is assigned a "key" code; each key code is crossreferenced
How to Build Your Own CornHole Game
How to Build Your Own CornHole Game DIMENSIONS Here is a diagram with the basic measurements for the Cornhole board game. SUPPLIES 1/2 thick sheet of plywood one 4 x4 or two 2 x4 s 8 long 2 4 s (4) 4 1/2
Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN 46787 Phone (260) 723-5131 Sales Fax (260) 723-6396 whitley@whitleyman.
Building Type Building Code Whitley Classroom Buildings BOCA, UBC, SBCCI, NEC, ADA Structural Support Outrigger construction standard, Whitley model classrooms. Main support beams to be 12 11.8# per lineal
Clad Direct Glaze Window Installation Instructions
Clad Direct Glaze Window Installation Instructions Sill flashing and sealing: 2. An overview of the proper flashing sequence is shown in figure 1. Please read entire installation instructions carefully
City of San Diego, CWP Guidelines
PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,
Roll Up Banners. Display Banners. Pop-Up Counter. Display Wall. Flags. Free Hanging Banners
Roll Up Banners Display Banners Pop-Up Counter Display Wall Flags Free Hanging Banners Roll Up Banner: Roll Up Regular A robust and professional looking free standing retractable display. The unit comes
Coat Racks Floor Racks Hooks Hangers Hook Panels Wardrobes
Coat Racks Floor Racks Hooks Hangers Hook s Wardrobes Phone: 913-281-4555 Fax: 913-281-4554 Website: www.emcospi.com E-mail: [email protected] Aluminum & Hardwood Coat Racks Whenever large groups gather
OCFRD TENT STANDARD 6000. This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.
1. Authority Orange County Fire Rescue Department Tents & Membrane Structures Office of The Fire Marshall - 109 E. Church Street, Lower Level - Orlando, Florida 32801-3319 Phone: 407-836-0004 Fax: 407-836-8310
ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24, 2014 06610-1
ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING January 24, 2014 06610-1 SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS MOLDED GRATING PART 1 - GENERAL 1.1 SCOPE OF WORK A. The CONTRACTOR
2.02. Specifications. General. Products. Execution. Offset Pivots P-694 Top and Bottom Pivots
2.02 Standard Specifications General Entrances Description Furnish all necessary materials, labor and equipment for the complete installation of aluminum entrance doors, door frames and hardware as shown
SECTION 08560 SERIES 1500 VINYL PATIO DOORS
SERIES 1500 VINYL PATIO DOORS PART 1 GENERAL 1.1 SECTION INCLUDES A. Patio Doors 1.2 RELATED SECTIONS A. Section 05450: Cold Formed Metal Framing. B. Section 06100: Rough Carpentry. C. Section 06200: Finish
Important Information for Installer & Homeowner
Important Information for Installer & Homeowner Homeowner: Please keep this information for your records, do not discard! Installation Instructions for Wood Frame Construction Replacement (See other side
EXHIBITIONS & DISPLAYS
EXHIBITIONS & DISPLAYS EXHIBITIONS & DISPLAYS The Exhibitions & Displays range offers a complete solution for all types of indoor and outdoor events, promotions, trade shows and exhibitions. The range
SCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS
PART 1 GENERAL SCENIC VIEW SV 10 SECTION 08 87 13 SOLAR CONTROL FILMS 1.1 SUMMARY A. Optically clear dual reflective, neutral sputtered and aluminum metallized polyester film for solar control. 1.2 RELATED
A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA
Page 1 of 10, Addendum No. 3 Temporary Garage Structure City of Chelsea, MA November 5, 2012 CBI Job No.: 12055-A A D D E N D U M # 3 DATE: November 5, 2012 TO: FROM: PROJECT: All Bidders Jenne dos Santos,
Andersen Electric Window Opener for Andersen Awning and Roof Windows
W A Electric Window Opener Electric Window Opener for Awning and Roof Windows Congratulations! You have just purchased one of the many fine products. For ease of installation and continued enjoyment of
39HQ Airovision Air Handling Units
39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport
The corrugated box: A profile and introduction
The corrugated box: A profile and introduction 1 More than just a plain brown box Ninety to ninety-five percent of U.S. manufactured goods are shipped to consumers in corrugated containers. In fact, more
GreenGuard Housewrap Installation Guide
000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be
DIY Advanced Dry Bags
DIY Advanced Dry Bags You can make dry bags to fit specific items, such as sleep pads, chairs, etc., by taking a few measurements and making allowances for seams, the bottom pleat and the roll-down closure.
Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS
Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS 1009.1 Stairway width. The width of stairways shall be determined as specified in Section 1005.1, but such width shall not be less than 44
Irvinton Village Apartments 2901 Fulton Houston, Texas 77009 Houston Housing Authority J. Allen Management Managing Agent
Irvinton Village Apartments 2901 Fulton Houston, Texas 77009 Houston Housing Authority J. Allen Management Managing Agent Scope for Irvinton Village Unit #512 Overall Scope: Demolition, Renovation, and
Roll-Up Door Maintenance Guide
R Roll-Up Door Maintenance Guide Cable Replacement on Two Spring Type Balancer Page 1 Panel Replacement - Removable Roller Cover Type Bottom Panel Page 1 Panel Replacement - Removable Roller Cover Type
CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS
CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings,
Basic Fire Door Requirements
TECHNICAL DATA SERIES S D I 118-01 Basic Fire Door Requirements 2001 Steel Door Institute STEEL DOOR INSTITUTE 30200 DETROIT ROAD - CLEVELAND, OHIO 44145 Technical Data Series SDI 118-2001 Basic Fire Door
HfHMD uses LP SmartSide siding and trim.
HfHMD uses LP SmartSide siding and trim. These products are: More durable than cement fiber board. Much more volunteer-friendly to install. When installed correctly, have a 5/50- year pro-rated warranty.
Can you design a frameless shower enclosure that doesn't leak?
Can you design a frameless shower enclosure that doesn't leak? With proper design and installation frameless shower enclosures should not have any problems with water leakage, but they are not 100 percent
ENIGMA-X SHOWER DOOR & TUB DOOR INSTALLATION INSTRUCTIONS
ENIGMA-X SHOWER DOOR & TUB DOOR INSTALLATION INSTRUCTIONS IMPORTANT DreamLine TM reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical