Philips Medical Systems DICOM Conformance Statement
|
|
|
- Gervase Cross
- 9 years ago
- Views:
Transcription
1 Philips Medical Systems DICOM Conformance Statement Gyroscan Intera R 7.5.1, R 8.1 and R 9.1 Document Number May 2002 Copyright Philips Medical Systems Nederland B.V. 2002
2 DICOM Conformance Statement Issued by: Philips Medical Systems Nederland B.V. Integrated Clinical Solutions, Interoperability Document Number: Building QV-282 P.O. Box DA Best The Netherlands Tel.: Fax.: Internet: ftp: ftp://ftp-wjq.philips.com/medical/interoperability/out/conformance_stmnts/pdf/mr91.pdf
3 DICOM Conformance Statement Table of Contents 1 Introduction Scope and field of application Intended audience Contents and structure Used definitions, terms and abbreviations References Important note to the reader General Acronyms and Abbreviations Implementation model Application Data Flow Diagram Functional definition of Application Entities Sequences of Real World Activities AE Specifications Gyroscan DICOM Worklist AE Specification Association Establishment Policies Association Initiation Policy Association Acceptance Policy Overview applied Modality Worklist Information Model Gyroscan DICOM Image Import AE Specification Association Establishment Policy Association Initiation Policy Association Acceptance Policy Gyroscan DICOM Image Export AE Specification Association Establishment Policies Association Initiation Policy Association Acceptance Policy Overview applied MR Image IOD Gyroscan DICOM Print AE Specification Association Establishment Policies Association Initiation Policy Association Acceptance Policy Overview applied Print management Communication Profiles Supported Communication Stacks Physical Media Support Extensions/Specializations/Privatizations Configuration AE Title/Presentation Address Configurable remote AE Titles and Presentation Addresses Configurable local parameters AE Title/Presentation Address mapping for Print Support of Extended Character Sets Remarks, Implementation restrictions and choices
4 DICOM Conformance Statement
5 Introduction 1 Introduction This section provides general information about the scope, intended audience and contents of this Conformance Statement and how to use it. 1.1 Scope and field of application The scope of this DICOM Conformance Statement is to facilitate data exchange between equipment of Philips Medical Systems and with equipment of other vendors. This document specifies the compliance to the DICOM standard, formally called the NEMA PS 3.X standards. It contains a short description of the applications involved and provides technical information about the data exchange capabilities of the equipment. The main elements describing these capabilities are: the supported DICOM Service Object Pair (SOP) Classes, Roles, Information Object Definitions (IOD), Service Elements and Transfer Syntaxes. The field of application is the integration of the Philips Medical Systems equipment into an environment of medical devices. This Conformance Statement should be read in conjunction with the DICOM standard and its addenda. 1.2 Intended audience This Conformance Statement is intended for: (potential) clients, marketing staff interested in data exchange functionality, system integrators and Customer Support Engineers of medical equipment, software engineers implementing DICOM interfaces. It is assumed that the reader is familiar with the DICOM standard. 1.3 Contents and structure The DICOM Conformance Statement is contained in section 2 through 7 and follows the contents and structuring requirements of DICOM PS Used definitions, terms and abbreviations DICOM definitions, terms and abbreviations are used throughout this Conformance Statement. For a description of these, see NEMA PS 3.3. The word Philips in this document refers to Philips Medical Systems. 1.5 References [DICOM] The Digital Imaging and Communications in Medicine (DICOM) standard: NEMA PS 3.X (X refers to the part 1-13) National Electrical Manufacturers Association (NEMA) Publication Sales 1300 N. 17th Street, Suite 1847 Rosslyn, Va , United States of America Page 5 of 38
6 Introduction 1.6 Important note to the reader This Conformance Statement by itself does not guarantee successful interoperability of Philips equipment with non-philips equipment. The user (or user s agent) should be aware of the following issues: Interoperability Interoperability refers to the ability of application functions, distributed over two or more systems, to work successfully together. The integration of medical devices into a networked environment may require application functions that are not specified within the scope of DICOM. Consequently, using only the information provided by this Conformance Statement does not guarantee interoperability. It is the user s responsibility to analyse thoroughly the application requirements and to specify a solution that integrates Philips equipment with non-philips equipment. Validation Philips equipment has been carefully tested to assure that the actual implementation of the DICOM interface corresponds with this Conformance Statement. Where Philips equipment is linked to non-philips equipment, the first step is to compare the relevant Conformance Statements. If the Conformance Statements indicate that successful information exchange should be possible, additional validation tests will be necessary to ensure the functionality, performance, accuracy and stability of image and image related data. It is the responsibility of the user (or user s agent) to specify the appropriate test suite and to carry out the additional validation tests. New versions of the DICOM Standard The DICOM Standard will evolve in future to meet the user s growing requirements and to incorporate new features and technologies. Philips is actively involved in this evolution and plans to adapt its equipment to future versions of the DICOM Standard. In order to do so, Philips reserves the right to make changes to its products or to discontinue its delivery. The user should ensure that any non-philips provider linking to Philips equipment, also adapts to future versions of the DICOM Standard. If not, the incorporation of DICOM enhancements into Philips equipment may lead to loss of connectivity (in case of networking) and incompatibility (in case of media). Page 6 of 38
7 Introduction 1.7 General Acronyms and Abbreviations. The following acronyms and abbreviations are used in the document. AE Application Entity ANSI American National Standard Institute DICOM Digital Imaging and Communication in Medicine DIMSE DICOM Message Service Element ELE Explicit VR Little Endian EBE Explicit VR Big Endian HIS Hospital Information System HL7 Health Level Seven ILE Implicit VR Little Endian IOD Information Object Definition NEMA National Electrical Manufacturers Association PDU Protocol Data Unit RIS Radiology Information System SCP Service Class Provider SCU Service Class User SOP Service Object Pair TCP/IP Transmission Control Protocol/Internet protocol UID Unique Identifier WLM Worklist Management Page 7 of 38
8 Implementation model 2 Implementation model The Gyroscan Intera (Gyroscan) system of Philips Medical Systems is an MR image generating system. The system contains: a DICOM Radiology Information System (RIS) interface to retrieve the worklist of patients to be examined. a DICOM Image Import function to receive DICOM MR images and image related data (originating from the same or other Gyroscan systems) from a remote DICOM node. a DICOM Image Export function to transfer DICOM MR images and image related data from the Gyroscan Intera to a remote system. a DICOM Image Print function to print MR images on a DICOM Network printer. These DICOM functions are described in this document. 2.1 Application Data Flow Diagram Gyroscan Intera is a system with four Application Entities (AE). The related Implementation Model is shown in Figure2-1 on page 9 The Gyroscan Intera DICOM Modality Worklist function requests the worklist from a DICOM Information System like a RIS. The function is initiated on the Gyroscan by the user selection of the Next patient from RIS function key. The Gyroscan Image Import function can be activated on request of a remote system. Imported images are to be used for reference only; when these are exported afterwards again no guarantee for consistency or completeness can be given. The Gyroscan operator can activate the DICOM Image Export function. The images to be sent are selected from one or more examinations. At export the images will be sent to a user selected remote destination. The images transferred are intended for viewing purposes; planscan information can be calculated from reference images. Graphics and annotations are not included. Post-processing like MPR, MIP, 3D reconstruction and rendering are possible, depending on the capabilities of the workstation receiving the MR images; for more detailed interpretation a large amount of information is stored in private elements. The Gyroscan DICOM Print function allows the Gyroscan operator to sent/print images on a DICOM network printer. Page 8 of 38
9 Implementation model Local Remote Request Worklist ( ) Gyroscan DICOM Worklist AE (section 3.1) Send Worklist Store Images ( ) Gyroscan DICOM Image Import AE (section 3.2) Store Image Image Export Request ( ) Gyroscan DICOM Image Export AE (section 3.3) Store Image Request to Print Image (3.4.2) Gyroscan DICOM Print AE (section 3.4) Print Image DICOM Standard Interface Figure 2-1: The Gyroscan DICOM Implementation Model 2.2 Functional definition of Application Entities The Gyroscan DICOM Worklist AE acts as a Service Class User (SCU) of the Basic Worklist Management Service Class. It will subsequently request the Worklist of Today and Tomorrow, it will receive the data from the configured RIS and display some of the received data on the user interface and store all data with the images resulting from the subsequent examinations. The Gyroscan DICOM Image Import AE acts as a Service Class Provider (SCP): the Gyroscan will respond to a remote request and store the images in the patient database. The Gyroscan DICOM Image Export AE acts as a Service Class User (SCU) of the Storage Service Class. The selected images and related image data are converted into a DICOM message to be sent to the remote system. Page 9 of 38
10 Implementation model The DICOM images will contain additional private elements, which have to be discarded by another DICOM system when modifying the images. These DICOM nodes are then responsible for data consistency. The Gyroscan DICOM Print AE acts as a Service Class User (SCU) of the Basic Grayscale Print Management Meta SOP Class. After selecting the images these can be sent to a DICOM network printer. 2.3 Sequences of Real World Activities RIS / HIS Gyroscan Intera 7.1 Modality Worklist Management BasicGrayscale Print Management DICOM printer MR Image Storage MR Image storage Workstation or PC PACS Table 2-1: The Gyroscan Intera 8.1 in a DICOM network When a RIS interface is configured, the worklist data can be requested from the RIS. After import of the data, the user can add missing data. Before or after this action a remote system can (be instructed to) send related images of one or more of the scheduled patients to the Gyroscan, for reference purposes only. Now the examination scan(s) are performed. After reconstruction the resulting images can be exported via DICOM (manually or by acquisition protocol). The DICOM node can be selected by the operator from the internal node list. The images can also be sent to a DICOM network printer. Page 10 of 38
11 3 AE Specifications Gyroscan contains four independent Application Entities. 3.1 Gyroscan DICOM Worklist AE Specification The Worklist AE provides Standard Extended Conformance to the following DICOM 3.0 SOP class as an SCU: Table 3-1: Supported SOP class by the Gyroscan DICOM Worklist AE as SCU SOP class Name UID DIMSE Modality Worklist Information Model - FIND C-FIND Association Establishment Policies General The Worklist AE has a PDU size of 16k Number of Associations The Worklist AE will attempt to establish one association at a time Asynchronous Nature The Gyroscan AE does not support asynchronous operations and will not perform asynchronous window negotiation Implementation Identifying Information The Implementation Class UID is: The implementation version name is: MR WLM Association Initiation Policy The Worklist AE initiates associations as a result of one Real-World Activity: the Gyroscan Intera operator requests for a new worklist Worklist Request Associated Real-World Activity The Worklist AE function will be accessible through the Gyroscan User Interface. An association will be set-up to the configured remote system (usually a RIS). Two worklists will be queried in one association: one for "today" and one for "tomorrow". After receiving Both worklists the association is released. Page 11 of 38
12 Proposed Presentation Contexts The Worklist AE will propose the following presentation contexts: Table 3-2: Proposed Presentation Contexts for the Worklist Presentation Context table Abstract Syntax Transfer Syntax Name UID Name List UID List Role Extended Negotiation Modality Worklist Information Model - FIND Modality Worklist Information Model - FIND Modality Worklist Information Model - FIND ILE SCU None ELE SCU None EBE SCU None SOP Specific Conformance to Modality Worklist Management Gyroscan provides standard conformance. An indication of the status of the C-FIND Responses (Success, Refused, Error) is displayed on the user interface in a message window. Table 3-3 gives an overview of the optional Return Keys that a WLM SCP (for instance a RIS) can return. Table 3-3: The applied optional WLM SCP Return Keys Module Scheduled Procedure Step Scheduled Procedure Step Description Applied optional Return Keys Scheduled Procedure Step Status Section on page 13 gives a detailed overview of all applied Matching and Return Keys and additional notes Association Acceptance Policy The Gyroscan DICOM Worklist AE does not accept associations. Page 12 of 38
13 3.1.4 Overview applied Modality Worklist Information Model This chapter specifies in detail the applied attributes in the C-FIND Service Element of this supported SOP Class. Note: * Attribute is used as a matching key. Table 3-4: Modality Worklist Information Model - FIND SOP Class - SOP Common Module Specific Character Set 0008,0005 Table 3-5: Modality Worklist Information Model - FIND SOP Class - Patient Identification Module Patient's Name 0010,0010 Can not handle = and \. Patient ID 0010,0020 Table 3-6: Modality Worklist Information Model - FIND SOP Class - Patient Demographic Module Patient's Birth Date 0010,0030 Patient's Sex 0010,0040 Patient's Weight 0010,1030 Page 13 of 38
14 Table 3-7: Modality Worklist Information Model - FIND SOP Class - Scheduled Procedure Step Module Scheduled Procedure Step Sequence 0040,0100 > Scheduled Station AE Title * 0040,0001 Applied value(s): The Gyroscan WLM AE Title is used. > Scheduled Procedure Step Start Date * > Scheduled Procedure Step Start Time > Scheduled Procedure Step Description 0040,0002 Applied value(s): <Today> or <Tomorrow> Old ACR_NEMA date formats (having ".") are not supported. 0040,0003 Old ACR_NEMA time formats (having ":") are not supported. 0040,0007 > Scheduled Procedure Step ID 0040,0009 > Scheduled Procedure Step Status 0040,0020 Table 3-8: Modality Worklist Information Model - FIND SOP Class - Requested Procedure Module Study Instance UID 0020,000D Table 3-9: Modality Worklist Information Model - FIND SOP Class - Imaging Service Request Module Accession Number 0008,0050 Referring Physician's Name 0008,0090 Page 14 of 38
15 3.2 Gyroscan DICOM Image Import AE Specification The Image Import AE provides Standard Conformance to the following DICOM V3.0 SOP Classes as an SCP: Table 3-10: Supported SOP Classes by the Gyroscan DICOM Image Import AE as SCP. SOP Class Name UID DIMSE MR Image Storage - STORE C-STORE Association Establishment Policy The Import AE accepts association with the following purpose: To allow remote applications to store images in the Gyroscan database General The Image Import AE has a PDU size of 32k Number of Associations The Import AE will accept one association at a time Asynchronous Nature The Import AE does not support asynchronous operations and will not perform asynchronous window negotiation Implementation Identifying Information The Implementation Class UID is: The implementation version name is: MR Store Association Initiation Policy The Gyroscan DICOM Worklist AE does not tries to establish any associations Association Acceptance Policy The Import AE accepts associations as a result of one Real-World activity: a remote station will request to store images on the Gyroscan Image Import Request Associated Real-World Activity After selection at a remote station and after selection of one of more images, these images can be sent to the Gyroscan Import AE. Page 15 of 38
16 Accepted Presentation Contexts The Import AE will accept the following presentation contexts:. Table 3-11: Acceptable Presentation Contexts for Image Export Request Presentation Context table Abstract Syntax Transfer Syntax Name UID Name List UID List Role Extended Negotiation MR Image Storage - STORE MR Image Storage - STORE MR Image Storage - STORE ILE SCP None ELE SCP None EBE SCP None SOP Specific Conformance C-STORE SCP DICOM MR Images with sequence attributes that were encoded as undefined length can not be imported. Only images made on a Gyroscan are allowed to be imported again (Manufacturer (0008,0070) should contain Philips ), these imported images are used for reference only, it is not intended to Export them again. Page 16 of 38
17 3.3 Gyroscan DICOM Image Export AE Specification The Image Export AE provides Standard Conformance to the following DICOM V3.0 SOP Classes as an SCU: Table 3-12: Supported SOP Classes by the Gyroscan DICOM Image Export AE as SCU. SOP Class Name UID DIMSE MR Image Storage - STORE C-STORE Association Establishment Policies General The PDU size of the Image Export AE is set to unlimited (0), this means that the PDU size of C- Store SCP is taken Number of Associations The Image Export AE will attempt to establish one association at a time Asynchronous Nature The Image Export AE does not support asynchronous operations and will not perform asynchronous window negotiation Implementation Identifying Information The Implementation Class UID is: The implementation version name is: MR Store Association Initiation Policy The Image Export AE initiates associations as a result of one Real-World activity: the Gyroscan operator requests for Image Export, i.e. send the selected images from the Gyroscan to a remote system Image Export Request Associated Real-World Activity After selection of a remote station and after selection of one of more images, these images will be sent when initiating the Export command. Gyroscan initiates one association to the selected remote entity and uses it to send the selected images via C-STORE requests (and receives the associated C-STORE Responses). The association is released by the Gyroscan after successful transfer of the images or when an error occurs. Page 17 of 38
18 Proposed Presentation Contexts The Image Export AE will propose the following presentation contexts: Table 3-13: Proposed Presentation Contexts for Image Export Request Presentation Context table Abstract Syntax Transfer Syntax Name UID Name List UID List Role Extended Negotiatio n MR Image Storage - STORE MR Image Storage - STORE MR Image Storage - STORE ILE SCU None ELE SCU None EBE SCU None SOP Specific Conformance C-STORE SCU The Image Export AE provides standard conformance. The behaviour on successful and unsuccessful transfer of images is given in the table below. Table 3-14: C-STORE STATUS Service Status Codes Further Meaning Status Refused A7xx Message on console. Error A9xx Message on console. Cxxx Message on console. Warning B00x Message on console.. Success 0000 Message on console. Page 18 of 38
19 Table 3-15 lists the applied Conditional (DICOM Type 1C and 2C) and Optional (DICOM Type 3) attributes of the standard MR Image IOD. A detailed overview of all applied attributes and additional notes are given in Table Table 3-15: Applied Conditional and Optional Attributes of the MR Image IOD Information Entity Module Conditional Attributes Optional Attributes Patient Patient - - Study General Study - Study Description Patient Study - Patient Weight Study Classification - - Series General Series Series Date, Series Time, Series Description, Protocol Name, Request Attributes Sequence, Scheduled Procedure Step Description Frame of Reference Frame of Reference - - Equipment General Equipment - Institution Name, Manufacturer's Model Name, Device Serial Number, Software Version(s), Station Name Image General Image Image Date, Image Time Referenced Image Sequence, Acquisition Number. Image Plane - - Image Pixel - - MR Image Modality LUT Repetition Time, Inversion Time, Trigger Time Rescale Intercept, Rescale Slope, Rescale Type. Number of Averages, Imaging Frequency, Imaged Nucleus, Echo Number(s), Magnetic Field Strength, Spacing Between Slices, Number of Phase Encoding Steps, Percent Sampling, Percent Phase Field of View, Low R-R Value, High R-R Value, Intervals Acquired, Intervals Rejected, Heart Rate, Receiving Coil, Transmitting Coil, Phase Encoding Direction, Flip Angle, Temporal Position Identified, Number of Temporal Positions, Reconstruction Diameter. VOI LUT Window Width Window Center SOP Common Specific Character Set Instance Creation Date, Instance Creation Time, Instance Creator UID Private MR Module Private - - Page 19 of 38
20 3.3.3 Association Acceptance Policy The Gyroscan DICOM Image Export AE does not accept associations Overview applied MR Image IOD The modules selected from the MR Image IOD module table of DICOM and the modules extended are given in the table below. Table 3-16: Applied Modules in the MR Image IOD Information Entity Module Reference Patient Patient Table 3-17 Study General Study Table 3-18 Patient Study Table 3-19 Study Classification Table 3-20 Series General Series Table 3-21 Frame of Reference Frame of Reference Table 3-22 Equipment General Equipment Table 3-23 Image General Image Table 3-24 Image Plane Table 3-25 Image Pixel Table 3-26 MR Image Table 3-27 Modality LUT Table 3-29 VOI LUT Table 3-30 SOP Common Table 3-31 Private MR Module Private Table 3-32 The details of these applied modules are given in the tables below. The situation that an attribute is present conditionally/optionally or that an attribute may contain a zero length value, is indicated too. Conditions and Defined/Enumerated Values of DICOM 3.0 are applicable but are not shown in the tables. The specified attributes are present and filled except for what is specified in the notes. Table 3-17: MR Image Storage SOP Class - Patient Module Patient's Name 0010,0010 The characters = and \ are not used. Received from RIS or entered by the operator Patient ID 0010,0020 Received from RIS or entered by the operator (this is the Registration Number) Patient's Birth Date 0010,0030 Received from RIS or entered by the operator Patient's Sex 0010,0040 Received from RIS or entered by the operator Applied value(s): F, M, O Page 20 of 38
21 Table 3-18: MR Image Storage SOP Class - General Study Module Study Date 0008,0020 Received from RIS or entered by the operator. Study Time 0008,0030 Received from RIS or entered by the operator. Accession Number 0008,0050 Received from RIS, entered by the operator or has a zero length value. Referring Physician's Name 0008,0090 Received from RIS, entered by the operator or has zero length value. Study Description 0008,1030 This is the Exam Name. Default value may be received from RIS (as Return Key Scheduled Procedure Step Description). Study Instance UID 0020,000D From RIS or created by Gyroscan for locally created images. Study ID 0020,0010 From RIS or created by Gyroscan for locally created images. Table 3-19: MR Image Storage SOP Class - Patient Study Module Patient's Weight 0010,1030 Received from RIS or entered by the operator Table 3-20: MR Image Storage SOP Class - Study Classification Module Study Comments 0032,4000 User defined comments about the Study. Table 3-21: MR Image Storage SOP Class - General Series Module Series Date 0008,0021 Date of the scan or reconstruction. Series Time 0008,0031 Time of the scan or reconstruction. Modality 0008,0060 Applied value(s): MR Series Description 0008,103E Short description of the scan. Protocol Name 0018,1030 This is the Scan Name. Patient Position 0018,5100 Applied value(s): FFDL, FFDR, FFP, FFS, HFDL, HFDR, HFP, HFS Series Instance UID 0020,000E Generated by Gyroscan. Page 21 of 38
22 Table 3-21: MR Image Storage SOP Class - General Series Module (Continued) Series Number 0020,0011 Created dynamically at export. Contains the concatenation of the acquisition number and the private reconstruction number. Request Attributes Sequence 0040,0275 Only send if received from RIS. > Scheduled Procedure Step Description 0040,0007 Only send if received from RIS. > Scheduled Procedure Step ID 0040,0009 Only send if received from RIS. Table 3-22: MR Image Storage SOP Class - Frame of Reference Module Frame of Reference UID 0020,0052 Position Reference Indicator 0020,1040 Has a zero length value. Table 3-23: MR Image Storage SOP Class - General Equipment Module Manufacturer 0008,0070 For locally created images this equals "Philips Medical Systems". Institution Name 0008,0080 "Hospital Name" as configured on the system. Station Name 0008,1010 For locally created images, Host name. Manufacturer's Model Name 0008,1090 For locally created images this is "Gyroscan Intera". Device Serial Number 0018,1000 For locally created images this is the SRN. Software Versions 0018,1020 Release text of original Image. Table 3-24: MR Image Storage SOP Class - General Image Module Image Date 0008,0023 Present if image is part of a dynamic scan. Image Time 0008,0033 Present if image is part of a dynamic scan. Referenced Image Sequence 0008,1140 Planscan information, a maximum of 3 earlier images on which the orientation of the current image has been defined. > Referenced SOP Class UID 0008,1150 Uniquely identifies the referenced SOP Class. > Referenced SOP Instance UID 0008,1155 Uniquely identifies the Referenced SOP Class. Acquisition Number 0020,0012 This is the Scan Number. Page 22 of 38
23 Table 3-24: MR Image Storage SOP Class - General Image Module (Continued) Image Number 0020,0013 Unique within the Series, implies a logical order of the Images (for viewing). Image comments 0020,4000 Table 3-25: MR Image Storage SOP Class - Image Plane Module Slice Thickness 0018,0050 Image Position (Patient) 0020,0032 Image Orientation (Patient) 0020,0037 Pixel Spacing 0028,0030 Table 3-26: MR Image Storage SOP Class - Image Pixel Module Rows 0028,0010 This is the Reconstructed Value. Columns 0028,0011 This is the Reconstructed Value. Pixel Aspect Ratio 0028,0034 Bits Stored 0028,0101 Applied value(s): 12, 8 High Bit 0028,0102 Applied value(s): 11, 7 Pixel Representation 0028,0103 Applied Value(s): 0 = unsigned integer. Pixel Data 7FE0,0010 Table 3-27: MR Image Storage SOP Class - MR Image Module Image Type 0008,0008 The element is extended with a fourth and fifth field, which contain the MR image type (R,I,M,P,CR etc.) and the MR scanning sequence. Table3-28 on page25 gives an overview of the valid combinations of Image Type values. Additionally to this list, for field 3 the values: PROJECTION IMAGE and MPR. Scanning Sequence 0018,0020 Applied value(s): GR, IR, RM, SE Sequence Variant 0018,0021 Applied value(s): MTC, OTHER, SK, SS Scan Options 0018,0022 MR Acquisition Type 0018,0023 Applied value(s): 2D, 3D Page 23 of 38
24 Table 3-27: MR Image Storage SOP Class - MR Image Module (Continued) Repetition Time 0018,0080 Echo Time 0018,0081 Inversion Time 0018,0082 Number of Averages 0018,0083 Imaging Frequency 0018,0084 Imaged Nucleus 0018,0085 Applied value(s): 1H, 31P. Echo Number(s) 0018,0086 Magnetic Field Strength 0018,0087 Spacing Between Slices 0018,0088 Number of Phase Encoding Steps 0018,0089 Echo Train Length 0018,0091 This is the Turbo Factor. Percent Sampling 0018,0093 This is the Reduction Factor or Scan Percentage. Percent Phase Field of View 0018,0094 This is the percentage in case of Rectangular FOV. Trigger Time 0018,1060 Present for Scan Options which include triggering (e.g. CG). Low R-R Value 0018,1081 High R-R Value 0018,1082 Intervals Acquired 0018,1083 Intervals Rejected 0018,1084 Heart Rate 0018,1088 Heart Rate as established as scan parameter prior to scan. Reconstruction Diameter 0018,1100 Filled with field of view in [mm] Receiving Coil 0018,1250 Only send if value applied. String on User Interface. Transmitting Coil 0018,1251 Phase Encoding Direction 0018,1312 This is the Preparation Direction or Foldover Direction. Flip Angle 0018,1314 Temporal Position Identifier 0020,0100 Dynamic Scan Number. Number of Temporal Positions 0020,0105 No. of Dynamic Scans. Samples per Pixel 0028,0002 Applied value(s): 1 Photometric Interpretation 0028,0004 Applied value(s): MONOCHROME2 Bits Allocated 0028,0100 Applied value(s): 16 Page 24 of 38
25 The next table describes the valid combinations of the image type values 1 to 5 and Scanning Sequence. Table 3-28: Valid combinations of Image Type applied values Image Type Value (1) Image Type Value (2) Image Type value (3) Image Type Value (4) Image Type value (5) Scanning Sequence ORIGINAL PRIMARY R_SE R SE SE ORIGINAL PRIMARY M_SE M SE SE ORIGINAL PRIMARY PHASE MAP P SE SE ORIGINAL PRIMARY R_IR R IR IR ORIGINAL PRIMARY I_IR I IR IR ORIGINAL PRIMARY M_IR M IR IR ORIGINAL PRIMARY PHASE MAP P IR IR ORIGINAL PRIMARY OTHER CR IR IR DERIVED PRIMARY T0 T0 DERIVED RM ORIGINAL PRIMARY T1 MAP T1 US RM ORIGINAL PRIMARY T2 MAP T2 US RM ORIGINAL PRIMARY DENSITY MAP RHO US RM ORIGINAL PRIMARY R_FFE R FFE GR ORIGINAL PRIMARY I_FFE I FFE GR ORIGINAL PRIMARY M_FFE M FFE GR ORIGINAL PRIMARY PHASE MAP P FFE GR ORIGINAL PRIMARY R_SI R SI RM ORIGINAL PRIMARY I_SI I SI RM ORIGINAL PRIMARY M_SI M SI RM ORIGINAL PRIMARY M_PCA M PCA GR ORIGINAL PRIMARY VELOCITY MAP P PCA GR DERIVED PRIMARY DERIVED DERIVED DERIVED RM DERIVED PRIMARY R R DERIVED RM DERIVED PRIMARY I I DERIVED RM DERIVED PRIMARY M M DERIVED RM DERIVED PRIMARY PHASE MAP P DERIVED RM Page 25 of 38
26 Table 3-28: Valid combinations of Image Type applied values (Continued) Image Type Value (1) Image Type Value (2) Image Type value (3) Image Type Value (4) Image Type value (5) Scanning Sequence DERIVED PRIMARY DIFFUSION MAP ADC DERIVED RM DERIVED PRIMARY RCBV RCBV DERIVED RM DERIVED PRIMARY RCBF RCBF DERIVED RM DERIVED PRIMARY MTT MTT DERIVED RM Table 3-29: MR Image Storage SOP Class - Modality LUT Module Rescale Intercept 0028,1052 Present if enabled in Gyroscan configuration file. Rescale Slope 0028,1053 Present if enabled in Gyroscan configuration file. Rescale Type 0028,1054 Present if enabled in Gyroscan configuration file. Applied value(s): US, normalised, milliseconds, milliradials, cm/sec, mm^2/sec The modality LUT Module data-elements are only sent in case this is configured on the scanner. If the modality LUT is present, the Rescale Intercept and Rescale Slope must be applied before the VOI LUT data is applied. Otherwise the window and level settings will not be correct. Table 3-30: MR Image Storage SOP Class - VOI LUT Module Window Center 0028,1050 To be applied after Modality LUT (=Rescaling). Window Width 0028,1051 See Window Center. Table 3-31: MR Image Storage SOP Class - SOP Common Module Specific Character Set 0008,0005 Applied value(s): ISO_IR 100 Instance Creation Date 0008,0012 Instance Creation Time 0008,0013 Instance Creator UID 0008,0014 SOP Class UID 0008,0016 Applied value(s): SOP Instance UID 0008,0018 Page 26 of 38
27 The following MR Module private contains private attributes on the Image and Series levels. Not all values are required in every image. Table 3-32: MR Image Storage SOP Class - MR Module Private Private Creator Group ,00xx VR = LO, VM = 1 Applied value(s): PHILIPS IMAGING DD 001 Chemical Shift 2001,xx01 VR = FL, VM = 1 Dimension: ppm Chemical Shift Number MR 2001,xx02 VR = IS, VM = 1 Applied value(s): Diffusion B-Factor 2001,xx03 VR = FL, VM = 1 Dimension: s/mm 2 Indicates the Diffusion coefficient. Diffusion Direction 2001,xx04 VR = CS, VM = 1 Indicates the Diffusion sensitive direction. Applied value(s): P, M, S, MP, PS, MS, I Image Enhanced 2001,xx06 VR = CS, VM = 1 Applied value(s): N, Y Image Type ED ES 2001,xx07 VR = CS, VM = 1 Indicates, whether an image is End Diastole or End Systole. Applied value(s): ED, ES, U Phase Number 2001,xx08 VR = IS, VM = 1 Identifies a phase interval of the cardiac cycle. Applied value(s):1.. (value tag 2001,xx17) Slice Number MR 2001,xx0A VR = IS, VM = 1 Identifies a slice within an acquisition and/or a reconstruction. Applied value(s):1.. (value tag 2001,xx18) Diffusion Echo Time 2001,xx11 VR = FL, VM = 1 Dimension: ms Indicates the Diffusion Echo time. The normal echo time is still valid for Diffusion. Dynamic Series 2001,xx12 VR = CS, VM = 1 Indicates a dynamic series. Applied value(s): Y (dynamic), N (standard) EPI Factor 2001,xx13 VR = SL, VM = 1 Echo Planar Imaging factor. Number of Echoes 2001,xx14 VR = SL, VM = 1 Number of Locations 2001,xx15 VR = SS, VM = 1 Gives the number of locations (chunks) used during acquisition of this scan, i.e. the distinct areas that have been excited. Number of PC Directions 2001,xx16 VR = SS, VM = 1 Specifies Phase Contrast Angio. Page 27 of 38
28 Table 3-32: MR Image Storage SOP Class - MR Module Private (Continued) Number of Phases MR 2001,xx17 VR = SL, VM = 1 Number of phases measured in a triggered acquisition. Number of Slices MR 2001,xx18 VR = SL, VM = 1 Number of different slice positions in one scan. Partial Matrix Scanned 2001,xx19 VR = CS, VM = 1 Applied value(s): N, Y PC Velocity 2001,xx1A VR = FL, VM = 1-n Dimension: cm/s Applied value(s): Velocity in L, P, H direction. Prepulse Delay 2001,xx1B VR = FL, VM = 1 Time between TFE prepulse and k=0 acquisition in subsequent TFE shot. Prepulse Type 2001,xx1C VR = CS, VM = 1 TFE prepulse type. Applied value(s): NO, Inv, SAT, ECHO, BBI Reconstruction Number MR 2001,xx1D VR = IS, VM = 1 Rank number of the reconstruction for a given scan. Respiration Sync 2001,xx1F VR = CS, VM = 1 Defines whether a measurement is respiration triggered and how it is triggered. Applied value(s): NO (no triggering), TRIGGERED (triggered), HOLD (breath hold), PEAR (Phase Encoded Artefact Reduction), GATE (gated) SPIR 2001,xx21 VR = CS, VM = 1 Applied value(s): NO, YES Water-Fat Shift (2001,xx22) VR = FL, VM = 1 Number of Slices in Stack 2001,xx2D VR = SS, VM = 1 The number of slices per stack. Stack Sequence 2001,xx5F VR = SQ, VM = 1-n Number of items is equal to value tag 2001,xx60 > Stack Radial Angle 2001,xx32 VR = FL, VM = 1 Dimension: deg Angle of two slices. > Stack Radial Axis 2001,xx33 VR = CS, VM = 1., Applied value(s): RL, AP, FH > Stack Slice Number 2001,xx35 VR = SS, VM = 1 Applied value(s): 1.. (value tag 2001,xx2D) > Stack Type 2001,xx36 VR = CS, VM = 1 Applied value(s): PARALLEL, RADIAL, ORTHOGO- NAL Number of Stacks 2001,xx60 VR = SL, VM = 1 Page 28 of 38
29 Table 3-32: MR Image Storage SOP Class - MR Module Private (Continued) Private Creator Group ,00xx VR = LO, VM = 1 Applied value(s): PHILIPS MR IMAGING DD 001 Synergy Reconstruction Type 2005,xx05 VR = CS, VM = 1 Applied Value(s): SYN_CLASSIC (for Synergy techniques) SYN_COCA (for the "Clear" technique) SENSE (for Sense technique) When this attribute contains the value SENSE the Element "Protocol Name" (0018,1030) contains the "scan name" from the User interface extended with the text-string "SENSE". This attribute can be created from release 8 onwards. Page 29 of 38
30 3.4 Gyroscan DICOM Print AE Specification The Print AE can support printing to one DICOM printer. The Print AE provides Standard Extended Conformance to the following DICOM 3.0 SOP class as an SCU: Table 3-33: Supported SOP Classes as SCU SOP Class Name UID DIMSE Basic Grayscale Print Management Meta SOP Class > Printer SOP Class N-GET > Basic Film Session SOP Class N-CREATE > Basic Film Box SOP Class N-CREATE N-ACTION > Basic Grayscale Image Box SOP Class N-SET Association Establishment Policies General The Print AE has a fixed PDU size, this value is Number of Associations Always one at the time. It releases the association with DICOM SCP if no operation is done on the association within 120 s. or by user cancellation Asynchronous Nature The Print AE does not support asynchronous operations and will not perform asynchronous window negotiation Implementation Identifying Information The AE implementation class UID is The implementation version name is MR Print Association Initiation Policy When the application submits a print job designated for a listed print server to the AE, the AE will request an association with the configured print server.for every supported printer the Association Initiation Policy can be configured, a list of attribute values can be configured. Page 30 of 38
31 Print Request Associated Real-World Activity The Print AE request causes the AE to initiate an Association Proposed presentation Contexts The Print AE will propose one of the presentation context listed in the next table. Table 3-34: Proposed Presentation Contexts for Print Presentation Context table Abstract Syntax Transfer Syntax Name UID Name List UID List Role Extended Negotiation Basic Grayscale Print Management SOP Class ILE SCU None SOP Specific Conformance to Print Management The N-EVENT-REPORT DIMSE Service is not supported for the Printer SOP Class by the Gyro- Scan system. When the system receives a N-EVENT-REPORT FAILURE a deadlock situation between the printer and the Gyroscan system can occur. The Gyroscan system does not detect the Printer Status FAILURE (N-GET). Instead of Releasing the Association the Print Job is continued Association Acceptance Policy The Gyroscan DICOM Worklist AE does not accept associations. Page 31 of 38
32 3.4.4 Overview applied Print management Note: Applied values other than mentioned below are NOT supported. Table 3-35: Basic Film Box SOP Class - Basic Film Box Presentation Module Image Display Format 2010,0010 Applied value(s): COL, CUSTOM, CUSTOM\1, ROW, SLIDE, STANDARD, STANDARD\1,1, SUPERSLIDE Film Orientation 2010,0040 Applied value(s): PORTRAIT Film Size ID 2010,0050 Applied value(s): 8INX10IN, 10INX12IN, 10INX14IN, 11INX14IN, 14INX14IN, 14INX17IN, 24CMX24CM, 24CMX30CM Magnification Type 2010,0060 Applied value(s): CUBIC Smoothing Type 2010,0080 SCP specific. Border Density 2010,0100 Applied value(s): BLACK Empty Image Density 2010,0110 Applied value(s): BLACK Min Density 2010,0120 Minimum density of the images on the film, expressed in hundredths of OD. Max Density 2010,0130 Maximum density of the images on the film, expressed in hundredths of OD. Trim 2010,0140 Applied value(s): NO Configuration Information 2010,0150 SCP Specific LUT. Table 3-36: Basic Film Box SOP Class - Basic Film Box Relationship Module Referenced Film Session Sequence 2010,0500 Parent Film Session. > Referenced SOP Class UID 0008,1150 > Referenced SOP Instance UID 0008,1155 Table 3-37: Basic Film Session SOP Class - Basic Film Session Presentation Module Number of Copies 2000,0010 Between 1 and 99. Print Priority 2000,0020 Attribute not present or the applied value is as given. Applied value(s): MED Medium Type 2000,0030 Applied value(s): BLUE FILM Film Destination 2000,0040 Applied value(s): MAGAZINE, PROCESSOR Film Session Label 2000,0050 Page 32 of 38
33 Table 3-38: Basic Grayscale Image Box SOP Class - Image Box Pixel Presentation Module Magnification Type 2010,0060 Applied value(s): CUBIC Smoothing Type 2010,0080 SCP specific. Image Position 2020,0010 Applied value(s): 1 Polarity 2020,0020 Applied value(s): NORMAL Preformatted Grayscale Image Sequence 2020,0110 > Samples per Pixel 0028,0002 Applied value(s): 1 > Photometric Interpretation 0028,0004 Applied value(s): MONOCHROME2 > Rows 0028,0010 Depending on the selected printer type and film size. > Columns 0028,0011 Depending on the selected printer type and film size. > Pixel Aspect Ratio 0028,0034 > Bits Allocated 0028,0100 Applied value(s): 8 > Bits Stored 0028,0101 Applied value(s): 8 > High Bit 0028,0102 Applied value(s): 7 > Pixel Representation 0028,0103 Applied value(s): 0x0000 > Pixel Data 7FE0,0010 Page 33 of 38
34 Communication Profiles 4 Communication Profiles 4.1 Supported Communication Stacks Gyroscan provides DICOM V3.0 TCP/IP Network Communication Support as defined in Part 8 of the DICOM Standard. No OSI stack communications are provided with this implementation Physical Media Support Gyroscan support Ethernet v2.0 and IEEE 802.3, 10/100 BASE-T. Page 34 of 38
35 Extensions/Specializations/Privatizations 5 Extensions/Specializations/Privatizations The following Standard Extensions are applied for the MR Image Storage SOP Class. See also the overview of the applied MR Image IOD in section on page 20. Table 5-1: Applied Standard Extensions Module Attribute Note Study Classification Study Comments Modality LUT Rescale Intercept Present if configured. Must be applied when viewing the image. Rescale Slope Rescale Type See note Rescale Intercept above. See note Rescale Intercept above. MR Module Private see Table3-32 on page 27 The modality LUT Module data-elements are only sent in case this is configured on the scanner. If the modality LUT is present, the Rescale Intercept and Rescale Slope must be applied before the VOI LUT data is applied.otherwise the window and level settings will not be correct. Page 35 of 38
36 Configuration 6 Configuration The Gyroscan system is configured by a Philips engineer only. The IP address and AE Titles of the Gyroscan are configurable. All are allowed to be equal.the listening port is for the DICOM Import Server is defined at AE Title/Presentation Address Configurable remote AE Titles and Presentation Addresses The following information of remote systems (acting as Service Class Provider) must be configured on the Gyroscan: The AE title. Default character Repertoire excluding control characters LF, FF, CR and ESC, maximum 16 bytes. The host name and IP addresses. The port number at which the remote system accepts association requests Configurable local parameters AE Titles The host name and IP addresses. "export" or "do not export" the Rescale attributes, see Table 5-1 on page 35. Institution Name, Table3-23, (0008,0080). RIS Worklist TimeOut, timeout for Worklist response: 0-30 sec. RIS Worklist Prefetch mode: no/yes. If yes, the RIS Worklist is requested again and kept for the next time. Depending on the frequency of use the RIS Worklist may run behind the actual situation. The user can refresh the RIS Worklist. Export TimeOut Sec.Default is 300 sec. 6.2 AE Title/Presentation Address mapping for Print A DICOM print server is identified by a printer name with associated parameters such as AE title, host name and port number. The IP address corresponding to a given host name is determined using the name look up database mechanisms provided on the hosting platform. Page 36 of 38
37 Support of Extended Character Sets 7 Support of Extended Character Sets Gyroscan supports Extended Character Set ISO_IR 100 which is the Latin alphabet No 1, supplementary set. If the RIS Worklist contans characters that are not ISO_IR 100 characters, the system will send a C-Cancel_RQ to RIS and a RIS ERROR message will be displayed. The Gyroscan will reject the RIS import. For Print the server provides no support for extended character sets in the communication with DICOM SCP s. Page 37 of 38
38 Remarks, Implementation restrictions and choices. 8 Remarks, Implementation restrictions and choices. The conditional Contrast Module is not implemented. Protocol Name (0018,1030) can be filled by the operator to contain the information relevant for MR. Future developments in user-interface with scanner controlled injectors will provide more detailed contrast information. Page 38 of 38
DICOM CONFORMANCE STATEMENT STORAGE SCU, Q/R SCP, PRINT SCU & STORAGE COMMITMENT SCU FOR TOSHIBA SUPERCONDUCTING MRI SYSTEMS (MIIMR0001EAB)
DICOM CONFORMANCE STATEMENT STORAGE SCU, Q/R SCP, PRINT SCU & STORAGE COMMITMENT SCU FOR TOSHIBA SUPERCONDUCTING MRI SYSTEMS FLEXART-series/VISART-series/ EXCELART-series/SECOND CONSOLE (MIIMR0001EAB)
HDI 4000 Ultrasound System
HDI 4000 Ultrasound System DICOM Conformance Statement Rev 1.0 Philips Medical Systems HDI 4000 DICOM Conformance Rev. 1.0 12/17/2001 Philips Medical Systems Table of Contents 0. Introduction...3 0.1 DICOM
DICOM Conformance Statement. CT Tomoscan M/EG/EG Compact Release 4.0. Document Number 4522 220 59691 30 March 2000
Philips Medical Systems DICOM Conformance Statement CT Tomoscan M/EG/EG Compact Release 4.0 Document Number 4522 220 59691 30 March 2000 Copyright Philips Medical Systems Nederland B.V. 2000 Philips Medical
Printlink5-ID_IV. DICOM 3.0 Conformance Statement PRINT MANAGEMENT SYSTEM CODE NO. 1118. Manufacturer:
PRINT MANAGEMENT SYSTEM Printlink5-ID_IV DICOM 3.0 Conformance Statement CODE NO. 1118 Manufacturer: 2970 Ishikawa-machi, Hachioji-shi Tokyo 192-8505 Japan DICOM Conformance Statement Important Notes Konica
DICOM Conformance Statement
Philips Medical Systems DICOM Conformance Statement Integris Systems with High Speed DICOM Image Interface MCV 2974 MCV 3621 Cardiac DICOM XA MCV 3761 Vascular DICOM XA MCV 3031 DICOM RIS Interface and
Dx MM DICOM 3.0 Conformance Statement
Dx MM DICOM 3.0 Conformance Statement NAME FONCTION VISA AUTHOR Alain Battistini Senior Engineer CONFORM TO ORIGINAL REVIEW Jean-François Hoh Senior Engineer CONFORM TO ORIGINAL APPROVAL Pascal Gilbert-Jeantet
DICOM Conformance Statement
DICOM Conformance Statement Page 1 of 14 1 Introduction... 3 2 Quick Summary... 4 3 Storing Studies... 6 3.1 Ideal Store scenario...6 3.2 Non-ideal scenarios...6 3.2.1 Accession number...7 3.2.2 No indication
Hologic Physician s Viewer 7.0 DICOM Conformance Statement
Hologic Physician s Viewer 7.0 DICOM Conformance Statement MAN-02386 REV 001 Page 1 of 32 1. Conformance Statement Overview This document is the DICOM Conformance Statement for Hologic Physician s Viewer,
DigitizingStation. DICOM V3.0 Conformance Statement
DigitizingStation DICOM V3.0 Conformance Statement Copyright 2004 by image diagnost GmbH Page 1 of 17 Image Diagnost International GmbH Reproduction of this document without prior written approval is prohibited.
DICOM Conformance Statement For Diagnostic Review Workstation Software Version 5-x MAN-00546
DICOM Conformance Statement For Diagnostic Review Workstation Software Version 5-x MAN-00546 SecurView DX DICOM Conformance Statement Part Number MAN-00546 Revision 001 For Software version 5-X Service
Version 8 DICOM Conformance Statement. Version 3.04, September 2014
Version 8 DICOM Conformance Statement Version 3.04, September 2014 1 Conformance Statement Overview The application described in this Conformance Statement VEPRO EMR Manager PACS is a collection of processes
Philips Medical Systems DICOM Conformance Statement
Philips Medical Systems DICOM Conformance Statement DSI Pro 1.0 Document Number 4522 164 07221 20 February 2001 Copyright Philips Medical Systems Nederland B.V. 2001 Page ii DICOM Conformance Statement
How To Write A Dicom Dicoma Dicomm Test Article
Technical Publications Direction 2183325 100 Revision 0, March 27, 1997 GENIE Processing & Review System, R1.7 DICOM 3.0 Conformance Statement Document Structure Information: The DICOM Print Services for
AGFA MEDICAL IMAGING DICOM Conformance Statement
MED/HB/000405 Page 1 of 19 AGFA MEDICAL IMAGING DICOM Conformance Statement ADC PRID - Software Version 1.1.09 SCU Worklist Management Page 2 of 19 MED/HB/000405 18 September, 2001 Agfa Medical Imaging
DICOM CONFORMANCE STATEMENT FOR ZIOSTATION 2.0
DICOM CONFORMANCE STATEMENT FOR ZIOSTATION 2.0 DICOM Conformance Statement, Ziostation 2.0 1 Copyright 2006-2011, Ziosoft, Inc. 0 DICOM CONFORMANCE STATEMENT OVERVIEW 4 0.1 APPLICATION DATA FLOW... 5 0.2
DICOM Conformance Statement
Inter Medical Medizintechnik GmbH Daimlerstr. 34-36 D-32312 Lübbecke Tel. (0 57 41) 23 59-0 Fax (0 57 41) 23 59-10 E-Mail Contact @Intmed.de www.intmed.de Doc. Rev. 1 GammaXP DICOM Conformance Statement
DICOM Conformance Statement. Version: 1.0
DICOM Conformance Statement Version: 1.0 Table of Contents 1 Preface...4 2 Overview...5 3 Introduction...5 3.1 Revision History...5 3.2 Audience...5 3.3 Remarks...6 3.4 Definitions, Terms and Abbreviations...6
DICOM 3.0 Conformance Statement
Picture Archiving and Communication System DICOM 3.0 Conformance Statement CODE NO.1245 Manufacturer: 1 Sakura-machi, Hino-shi Tokyo 191-8511, Japan Important Notes Konica Minolta Medical & Graphic, Inc.
DICOM Conformance Statement Merge Eye Care PACS v. 4.0
DICOM Conformance Statement Merge Eye Care PACS v. 4.0 Merge Healthcare 900 Walnut Ridge Drive Hartland, WI 53029 USA 877.44.MERGE 2012 Merge Healthcare. The information contained herein is confidential
g GE Medical Systems Advantage Cluster Storage / Archive System Release 1 v1.1.5.2 Conformance Statement Direction number: 2160628 Revision: 2
g GE Medical Systems Advantage Cluster Storage / Archive System Release 1 v1.1.5.2 Conformance Direction number: 2160628 Revision: 2 Date: September 20, 1996 Revision History Revision Date Author Reason
ONIS 2.0 DICOM CLIENT. DICOM 3 Conformance statement
ONIS 2.0 DICOM CLIENT DICOM 3 Conformance statement Table of Contents 0 Introduction...4 0.1 Scope...4 0.2 Standards...4 0.3 Intended Audience...4 0.4 Important Remarks...4 0.5 Definitions...4 1 Implementation
DICOM Conformance Statement FORUM
DICOM Conformance Statement FORUM Version 3.1 Carl Zeiss Meditec AG Goeschwitzerstraße 51-52 07745 Jena Germany www.meditec.zeiss.com Document: DICOM Conformance Statement_FORUM_3.1.doc Page 1 of 25 1
MammoView 1.5. DICOM Conformance Statement 1.0. medigration GmbH All rights reserved
All rights reserved medigration GmbH, Schuhstr. 30, 91052 Erlangen Tel: +49 (0) 9131/69087-40, Fax: +49 (0) 9131/69087-50 www.medigration.de Copyright. All rights reserved. Table of Contens 1 Introduction...
GE PACS Conformance Statement for DICOM v3.0
g GE Medical Systems Technical Publications IIS P/N 4361668 Revision 01 GE PACS Conformance Statement for DICOM v3.0 Copyright 1998 By General Electric Company g GE Medical Systems GE Medical Systems,
Technical Publication. DICOM Conformance Statement. DICOM Proxy 2.0. Document Revision 3. October 20, 2010. 2010 Copyright Brainlab AG
Technical Publication DICOM Conformance Statement Document Revision 3 October 20, 2010 2010 Copyright Brainlab AG 1 Conformance Statement Overview This is a conformance statement for the Brainlab software
Technical Publications
g GE Healthcare Technical Publications Direction DOC0855383 Revision 2 Centricity TM RIS-i MedoraCom 4.2 Plus Copyright 2011 by General Electric Co. Do not duplicate REVISION HISTORY REV DATE REASON FOR
DICOM Conformance Statement Print Management Service Class FUJI NETWORK PRINT SERVER FN-PS551
DICOM Conformance Statement Print Management Service Class FUJI NETWORK PRINT SERVER FN-PS55 October 006 5th Edition Copyright FUJIFILM Corporation, Japan 897N00094A (006-03-40) 006.0 Revision History
HP Medical Archive Solutions DICOM Conformance Statement. January 2007 (Third Edition) Part Number T4434-96003
HP Medical Archive Solutions DICOM Conformance Statement January 2007 (Third Edition) Part Number Copyright 2007, 2007 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license
DICOM. Conformance Statement. Envisor Software Version C.0
DICOM Conformance Statement Envisor Software Version C.0 COPYRIGHT KONINKLIJKE PHILIPS ELECTRONICS N.V. 2005. ALL RIGHTS RESERVED. NO PART OF THIS PUBLICATION MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM
Technical Publications
g GE Healthcare Technical Publications Direction 1007228 Revision 0 Navigation Plus System Version 5.2 For DICOM Copyright 2004 by General Electric Co. Do not duplicate THIS PAGE LEFT INTENTIONALLY BLANK
Infinity Medical Image Server
Infinity Medical Image Server DICOM Server Conformance Statement Part Number: 900-420-002 Rev. 02 Document/Software Version: v1.3.0 Date: May 12, 2009 Copyright 2008-2009 Codonics, Inc. All Rights Reserved.
MiPACS Storage Server Conformance Statement Version 1.02.0.000
MiPACS Storage Server Conformance Statement Version 1.02.0.000 December 2009 Version 1.00.4.001 Conformance Statement Document Information Issued by: Medicor Imaging 1927 S. Tryon St., Suite 200 Charlotte,
DICOM CONFORMANCE STATEMENT FOR ZIOCUBE 1.0
DICOM CONFORMANCE STATEMENT FOR ZIOCUBE 1.0 DICOM Conformance Statement, ZioCube 1.0 1 Ziosoft, Inc. 0 DICOM CONFORMANCE STATEMENT OVERVIEW 4 0.1 APPLICATION DATA FLOW...5 0.2 FUNCTIONAL DEFINITION OF
DICOM Conformance Statement CBS Images and Worklist Version 2.01
DICOM Conformance Statement CBS Images and Worklist Version 2.01 Compulink Inc. 1100 Business Center Circle Thousand Oaks, CA 91320 Internal document number: 4226-000-000-001 rev 1 Creation Date: 20131101
DICOM Conformance Statement
Date: 2010-10-7 DICOM Conformance Statement Stratus OCT Instrument and Review Software Version 7.0 Carl Zeiss Meditec, Inc. 5160 Hacienda Drive Dublin, CA 94568 USA www.meditec.zeiss.com Document: DICOM_Conformance_Statement_Stratus_7.0.doc
DICOM Conformance Statement
Carestream DryView 5700 Laser Imager DICOM Conformance Statement June 15, 2011 Document # 8J5397 PAGE 1 of 40 This publication is protected by Federal Copyright law, with all rights reserved. Note: Publication
Centricity TM RISi DICOM Conformance Statement
Technical Publications Direction No 2118780 Release 3.12 and 4.2 - General Electric Company - All rights reserved. Table of Contents 1 Introduction 4 1.1 Overview 4 1.2 OVERALL DICOM CONFORMANCE STATEMENT
Candelis, Inc. DICOM Conformance Statement. ImageGrid Storage Server
18821 Bardeen Ave. Irvine, CA 92612 Phone: 800.800.8600 Fax: 949.752.7317 Candelis, Inc. DICOM Conformance Statement ImageGrid Storage Server 0 INTRODUCTION ImageGrid Storage Server is a complete hardware/software,
DICOM 3.0 Conformance Statement
Version 2.7 DICOM 3.0 Conformance Statement 1 1. Conformance Statement Overview SOP Classes Query and Retrieve Study Root Query/Retrieve Information Model Find Study Root Query/Retrieve Information Model
Medflow Imaging DICOM Server
DICOM Server version 7.6.2 Revision 2.0 Copyright 2011 Medflow, Inc. Revision History Date June 14, 2011 August 30, 2011 Rev Description 7.6.1 First version. 7.6.2 Revised to reflect version 7.6.2 changes
CARESTREAM PACS Suite (Client, Server, and CD Direct) Version 11.0. DICOM Conformance Statement
CARESTREAM PACS Suite (Client, Server, and CD Direct) Version 11.0 DICOM Conformance Statement Publication # 8G8913 22 April 2009 Table of Contents Table of Contents...2 1 Introduction...5 1.1 Abbreviations
DICOM 3.0 CONFORMANCE STATEMENT
DICOM 3.0 CONFORMANCE STATEMENT JETStream Workspace Version 1.0 9705-0067, Rev A October, 004 Copyright Statement Philips Medical Systems has taken care to ensure the accuracy of this document. However,
GENIE Acquisition R3.1 Conformance Statement for DICOM v3.0
Technical Publications Direction 2358711-100 Revision 0 GENIE Acquisition R3.1 Conformance Statement for DICOM v3.0 This document applies to the following systems: Millennium MPR/MPS, MG and MC Optima
DV5950 DICOM Conformance Statement. Product: DryView 5950 Laser Imaging System
DV5950 DICOM Conformance Statement Product: DryView 5950 Laser Imaging System Document # 9J5331 Author: Shobha Murthy This publication is protected by Federal Copyright law, with all rights reserved. Note:
Technical Publications
g GE Healthcare Technical Publications Direction DOC1486636 Revision 2 Optima CT Dicom Conformance Statement for DICOM * Refer to section 1 for a list of products in the Optima CT families to which this
DOLPHIN DICOM IMAGING DICOM CONFORMANCE STATEMENT
DOLPHIN DICOM IMAGING DICOM CONFORMANCE STATEMENT NOTICE The software described in this document has been validated in accordance with the governing DICOM standard at the time of this document's release.
Xeleris 2.0 Conformance Statement for DICOM V3.0
g GE Healthcare Technical Publications DIRECTION 5168972-100 Revision 2 Xeleris 2.0 Conformance Statement for DICOM V3.0 Document Structure Information: The DICOM Print Services for Xeleris are defined
AquariusNET DICOM Conformance Statement. DICOM Conformance Statement. AquariusNET 4.4. Rev. 12.03.2015 B
DICOM Conformance AquariusNET 4.4 Rev. 12.03.2015 B 1 1 Conformance Overview The AquariusNET server is a 2D/ 3D enterprise thin client-server solution. This central 3D processing server streams real-time
Technical Publications
g GE Healthcare Technical Publications Direction 5357330-1EN (DOC1498472) Revision 3 Xeleris 3.0 and Xeleris 3.1 DICOM CONFORMANCE STATEMENT Copyright 2014 by General Electric Co. Do not duplicate g GE
Varian System Server. DICOM Conformance Statement
Varian System Server DICOM Conformance Statement P/N VA8005D3CS July 2007 General Information Abstract This document provides information about the DICOM Conformance of the Varian System Server product
Table of Contents. Version History
Table of Contents 1. Introduction... 1 2. Implementation Model... 1 2.1 Application Data Flow Diagram... 1 2.2 Functional Definition of AE s... 2 2.3 Sequencing of Real World Activities... 2 3. AE Specifications...
ConnectPro for CT/i 4.0 Systems Conformance Statement for DICOM v3.0
Technical Publications Direction 2210573-100 Revision 0 ConnectPro for CT/i 4.0 Systems Conformance Statement for DICOM v3.0 Copyright 1998 by General Electric Company GE Medical Systems: Telex 3797371
DICOM Conformance Statement
DICOM Conformance Statement CARESTREAM Vue PACS v11.3.2.4 Lesion Management and Bookmark Applications Part # 6K4188 2012-07-02 PAGE 1 of 142 Table of Contents 1 INTRODUCTION... 4 1.1 ABBREVIATIONS AND
DICOM Conformance Statement
This printed copy is not subject to any change control XXXXXXXXXXXXxxXXXXXXXXXXXXXXXXXXX MR 2013-03-14 Siemens AG 2013 All rights reserved Siemens AG Healthcare Sector, Henkestr. 127, D-91050 Erlangen,
Digital Imaging and Communications in Medicine (DICOM) Part 4: Service Class Specifications
Digital Imaging and Communications in Medicine (DICOM) Part 4: Service Class Specifications Published by National Electrical Manufacturers Association 1300 N. 17th Street Rosslyn, Virginia 22209 USA Copyright
DICOM Conformance Statement
Document Number: 67923 Revision: B Date: 2009-01-15 Author: Sonia Yu DICOM Conformance Statement Cirrus HD-OCT Instrument and Review Software Version 4.0 Carl Zeiss Meditec, Inc. 5160 Hacienda Drive Dublin,
DICOM Conformance Statement. GDxPRO
Document Number: 2660021133317 Revision: D Date: 01/20/2010 Author: Vidya Kulkarni DICOM Conformance Statement GDxPRO GDxPRO Instrument Software Version 1.1 GDxPRO Review Software Version 1.0 Carl Zeiss
DICOM Conformance Statement. DICOMscope 3.5. Software developed by: M. Eichelberg 1, K. Kleber 2, J. Riesmeier 1, A. Schröter 2, A.
DICOM Conformance Statement DICOMscope 3.5 Software developed by: M. Eichelberg 1, K. Kleber 2, J. Riesmeier 1, A. Schröter 2, A. Thiel 1 Organizational support: J. Holstein 2, H. Oosterwijk 3 1) Kuratorium
CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH
CT RADIATION DOSE REPORT FROM DICOM Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH CT Patient comes out... Patient goes in... Big Black Box Radiology
AGFA HEALTHCARE DICOM Conformance Statement
Page 1 of 79 AGFA HEALTHCARE DICOM Conformance Statement IMPAX 6.5 Solution Document No. 001310 Revision: 1.1 When printed, this is NOT a controlled document. Page 2 of 79 Document Information Service-related
Technical Publications
GE Healthcare Technical Publications Direction 5720690-1EN Revision 1 AW Server 3.2 CONFORMANCE STATEMENT for DICOM do not duplicate Copyright 2015 By General Electric Co. THIS PAGE LEFT INTENTIONALLY
Kodak PACS Link Medical Image Manager 200 Kodak PACS Link 25 Print Server as Print Server (SCP) Software Version 6.1.1
Kodak PACS Link Medical Image Manager 200 Kodak PACS Link 25 Print Server as Print Server (SCP) Software Version 6.1.1 DICOM Conformance Statement June 30, 2005 Document # 3E5252, Rev. J Revision History
DICOM Conformance Statement
Date: 2014-12-18 DICOM Conformance Statement CIRRUS TM HD-OCT 5000 and 500 Instrument Version 7.5/8.0 Carl Zeiss Meditec, Inc. 5160 Hacienda Drive Dublin, CA 94568 USA www.meditec.zeiss.com Document: DICOM_Conformance_Statement_CIRRUS_7.5_8.0.Docx
SIGNA PROFILE CONFORMANCE STATEMENT
Technical Publications Direction 2174981 Revision 1.0 SIGNA PROFILE CONFORMANCE STATEMENT for DICOM v3.0 (ID/Net v3.0) sm - Service Manual do not duplicate Copyright 1996 by General Electric Company blank
DICOM Conformance Statement
DICOM Conformance Statement IntelliSpace Breast R3.1 Multi-modality features powered by IntelliSpace Clinical Applications R9.1V7 Koninklijke Philips Electronics N.V. 2013 All rights are reserved. Issued
Conformance Statement
DICOM Conformance Statement StentBoost / Integris 3D-RA SW Release 4.2.1 Koninklijke Philips Electronics N.V. 2004 All rights are reserved. Issued by: Philips Medical Systems Nederland B.V. Medical IT,
DICOM Conformance Statement. Veradius Unity
DICOM Conformance Statement Veradius Unity Koninklijke Philips Electronics N.V. 2014 All rights are reserved. Document Number: ICAP-PF.0008674 Issued by: Philips Healthcare Philips Nederlands Best P.O.
DICOM Conformance Statement
DICO Conformance Statement IDS5 11.4; IDS7, Sectra Healthcare Server, WISE, ImageServer/s, ImageServer/xd Version 12.2.3, June 2010 About this document Sectra Imtec AB, Sweden, 2010 Disclaimer Sectra Imtec
Digital Imaging and Communications in Medicine (DICOM) Supplement 119: Frame Level Retrieve SOP Classes
Page i 5 Digital Imaging and Communications in Medicine (DICOM) Supplement 119: Frame Level Retrieve SOP Classes 10 15 20 Prepared by: Working Group 6 DICOM Standards Committee, Working Group 6 1300 N.
LONI De-Identification Policy
The following defines how different file formats are de-identified with LONI tools. Each metadata attribute of each file can have the following operations performed: Operation keep Remove Replace Description
DICOM Conformance Statement
Document Number: CG-S2F-MS-039 Revision: 1.0 Date: 2011-05-31 DICOM Conformance Statement FORUM LINK net Version 1.0 Carl Zeiss Meditec AG Göschwitzer Strasse 51-52 07745 Jena Germany www.meditec.zeiss.com
Extracting, Storing And Viewing The Data From Dicom Files
Extracting, Storing And Viewing The Data From Dicom Files L. Stanescu, D.D Burdescu, A. Ion, A. Caldare, E. Georgescu University of Kraiova, Romania Faculty of Control Computers and Electronics www.software.ucv.ro/en.
PARCA Certified PACS Interface Analyst (CPIA) Requirements
PARCA Certified PACS Interface Analyst (CPIA) Requirements Copyright notice: Copyright 2005 PACS Administrators in Radiology Certification Association (PARCA). All rights reserved. All rights reserved.
ClearCanvas ImageServer DICOM Conformance Statement
ClearCanvas ImageServer DICOM Conformance Statement Document Version: 2.2 Product Name(s): ClearCanvas ImageServer Release: 11.0 Date: January 12, 2014 ClearCanvas Inc. 1920 439 University Ave. Toronto,
Technical Publications
Technical Publications Direction DOC0708777 Revision 3 Centricity Enterprise Archive V4.0 DICOM CONFORMANCE STATEMENT Copyright 2011 by General Electric Company 1 CONFORMANCE STATEMENT OVERVIEW The Enterprise
Carestream DirectView CR System Software Version 5.6. DICOM Conformance Statement. March 2, 2012 Document Number 9J6333 Ver 1.0
Carestream DirectView CR System Software Version 5.6 DICOM Conformance Statement March 2, 2012 Document Number 9J6333 Ver 1.0 Table of Contents 1 INTRODUCTION...4 1.1 EXECUTIVE OVERVIEW...4 1.2 SCOPE AND
DICOM Correction Proposal
DICOM Correction Proposal STATUS Assigned Date of Last Update 20165/01/08 Person Assigned Submitter Name Harry Solomon Harry Solomon Submission Date 2015/09/21 Correction Number CP-1550 Log Summary: Refactor
DICOM Conformance Statement
Revision: 1.0 Date: Sep, 15th 2015 DICOM Conformance Statement VISUCAM 224 and VISUCAM 524 Version 6.0 Carl Zeiss Meditec AG Goeschwitzer Strasse 51-52 07745 Jena Germany www.zeiss.com/med Document: DICOM_Conformance_Statement_VISUCAM_224_524_6.0.doc
DICOM Correction Item
Correction Number DICOM Correction Item CP-626 Log Summary: Type of Modification Clarification Rationale for Correction Name of Standard PS 3.3 2004 + Sup 83 The description of pixel spacing related attributes
NEMA Standards Publication PS 3 Supplement 41. Digital Imaging and Communications in Medicine (DICOM) Digital Signatures
NEMA Standards Publication PS 3 Supplement 1 Digital Imaging and Communications in Medicine (DICOM) Digital Signatures Status: Final Text Sep 001 Prepared by DICOM Standards Committee, Working Group 1
Digital Imaging and Communications in Medicine (DICOM) Part 10: Media Storage and File Format for Media Interchange
Digital Imaging and Communications in Medicine (DICOM) Part 10: Media Storage and File Format for Media Interchange Published by National Electrical Manufacturers Association 1300 N. 17th Street Rosslyn,
NETWORK MANAGEMENT FOR PICTURE ARCHIVING AND COMMUNICATION SYSTEMS
NETWORK MANAGEMENT FOR PICTURE ARCHIVING AND COMMUNICATION SYSTEMS by Edlic Nga-Lik Yiu B.A.Sc., Simon Fraser University, 2000 Edwood Nga-Wood Yiu B.A.Sc., Simon Fraser University, 2000 PROJECT SUBMITTED
DICOM CONFORMANCE STATEMENT
Technical Publications Revision 3 Reporting Tool 2.7 DICOM CONFORMANCE STATEMENT Copyright 2005-2010 by General Electric Co. Do not duplicate Page 1 of 34 REVISION HISTORY Revision Date Reason for Change
Digital Imaging and Communications in Medicine (DICOM) Part 1: Introduction and Overview
Digital Imaging and Communications in Medicine (DICOM) Part 1: Introduction and Overview Published by National Electrical Manufacturers Association 1300 N. 17th Street Rosslyn, Virginia 22209 USA Copyright
DICOM CONFORMANCE STATEMENT
Technical Publications Revision 2 Reporting Tool DICOM CONFORMANCE STATEMENT Copyright 2005-2009 by General Electric Co. Do not duplicate Page 1 of 31 REVISION HISTORY Revision Date Reason for Change A
DICOM CONFORMANCE STATEMENT
g GE Healthcare Technical Publications Direction 2067192-001 Revision 4 Universal Viewer* Web Client Version 5.0 SP5 * Trademark of General Electric Company Copyright 2014 by General Electric Co. Do not
DICOM: Definitions and Testing
DICOM: Definitions and Testing Bruce Curran University of Michigan (AAPM Representative, DICOM WG-7 Walter R. Bosch Advanced Technology Consortium Washington University of St. Louis Acknowledgements Sam
IHE Radiology (RAD) Technical Framework. Volume 2 IHE RAD TF-2 Transactions
Integrating the Healthcare Enterprise 5 IHE Radiology (RAD) Technical Framework 10 Volume 2 IHE RAD TF-2 Transactions 15 20 Revision 15.0 Final Text July 29, 2016 25 Please verify you have the most recent
Implementation of DICOM Modality Worklist at Patient Registration Systems in Radiology Unit
EPJ Web of Conferences 68, 000028 (2014) DOI: 10.1051/ epjconf/ 20146800028 C Owned by the authors, published by EDP Sciences, 2014 Implementation of DICOM Modality Worklist at Patient Registration Systems
Digital Imaging and Communications in Medicine (DICOM) Part 1: Introduction and Overview
Digital Imaging and Communications in Medicine (DICOM) Part 1: Introduction and Overview Published by National Electrical Manufacturers Association 1300 N. 17th Street Rosslyn, Virginia 22209 USA Copyright
9 Working With DICOM. Configuring the DICOM Option
9 Working With DICOM DICOM (Digital Imaging and Communications in Medicine) is a format created by NEMA (National Electrical Manufacturers Association) to aid in the distribution and viewing of medical
DICOM Conformance Statement. CR Console. (Standard) Copyright FUJIFILM Corporation, Japan. June 2007 10th Edition 897N0547D (010-113-90)
DICOM Conformance Statement CR Console (Standard) June 2007 10th Edition Copyright FUJIFILM Corporation, Japan 897N0547D (010-113-90) Revision History History Date Revision Description 1st Edition April,
Digital Imaging and Communications in Medicine (DICOM) Part 10: Media Storage and File Format for Media Interchange
Digital Imaging and Communications in Medicine (DICOM) Part 10: Media Storage and File Format for Media Interchange Published by National Electrical Manufacturers Association 1300 N. 17th Street Rosslyn,
Understanding Digital Modalities: System Integration and Use
Understanding Digital Modalities: System Integration and Use Donald J. Peck, PhD Henry Ford Health System Detroit, MI [email protected] Dicom Digital Imaging and Communications in Medicine Part 3: Information
Workstation, Server Hosted
Workstation, Server Hosted With so many PACS out there, Why just make another? So, we didn't. Distribute, Burn, Print, Import, Archive The Internet DICOM Eye Web Web Viewer PACStoGo DICOM Distribution
Tools for DICOM Implementation
DICOM INTERNATIONAL CONFERENCE & SEMINAR Oct 9-11, 2010 Rio de Janeiro, Brazil Tools for DICOM Implementation David Clunie CoreLab Partners, Inc. Outline Tools for DICOM implementation Toolkits and sample/reference
Cenova Image Analytics Server DICOM Conformance Statement
breast imaging solutions DICOM Standard Interface Cenova Image Analytics Server DICOM Conformance Statement Software Version 2.3 MAN-03715 rev 001 Cenova Image Analytics Server 2.3 DICOM Conformance Statement
SITE IMAGING MANUAL ACRIN 6698
SITE IMAGING MANUAL ACRIN 6698 Diffusion Weighted MR Imaging Biomarkers for Assessment of Breast Cancer Response to Neoadjuvant Treatment: A sub-study of the I-SPY 2 TRIAL Version: 1.0 Date: May 28, 2012
