1 Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone! GSM RTU GSM SMS Alarm Unit RTU5000 User Manual Ver 1.1 Date Issued: All rights reserved by King Pigeon Hi-Tech. Co., Ltd. Website: Page 1 of 17 King Pigeon Hi-Tech. Co., Ltd. Page 1 of 17 Ver 1.1 File No.:KPRTU500011
2 Table of contents 1. Brief introduction Safety Directions Standard Packing list Physical Layout Features Settings Operation Installation Technical specifications Quality Warranty Trouble Shooting Guide This handbook has been designed as a guide to the installation and operation of GSM RTU RTU5000. Statements contained in the handbook are general guidelines only and in no way are designed to supersede the instructions contained with other products. We recommend that the advice of a registered electrician be sought before any Installation work commences. King Pigeon Hi-Tech.Co., Ltd, its employees and distributors, accept no liability for any loss or damage including consequential damage due to reliance on any material contained in this handbook. King Pigeon Hi-Tech.Co., Ltd, its employees and distributors, accept no liability for GSM Network upgrading or SIMCard upgrading due to the technology specifications contained in this handbook. Updated Version Details Item Ver1.0 Ver1.1 Counter Only IN3 can be used as Counter All Inputs (4) can be used as Counters Counter Report Period Min.10Seconds, Max Seconds Min.1minute, Max minutes Page 2 of 17 King Pigeon Hi-Tech. Co., Ltd. Page 2 of 17 Ver 1.1 File No.:KPRTU500011
3 1. Brief introduction The GSM RTU(Remote Terminal Unit) RTU5000 is a universal GSM Remote Control and Alarm Unit. it provides 2 Opt coupler (Iso) outputs, 4 Opt coupler (Iso) inputs, 4 of the 4 Opt coupler inputs can be used as counter function, 1 AD input(0-5v) can setup Higher and Lower Value to alarm, and RS232 Serial Port. It allows you to monitor and control an alarm or remote stations or equipments or machines by SMS(Short Message Service). The GSM RTU5000 suitable for below applications: 1. Security Alarm System applications; 2. Supervision and monitoring alarm systems; 3. Automatic monitoring system; 4. Vending Machines security protection; 5. Pumping Stations, Tanks, Oil or Water levels; 6. Buildings and Real Estate; 7. Weather Stations; 8. River Monitoring and Flood Control; 9. Oil and gas pipelines; 10. Corrosion protection 11. Temperatures, water leakage applications; 12. Wellheads, boat, vehicle; 13. Energy saving, street lights control system; 14. Valve controls; 15. Transformer stations; 16. Unmanned machine rooms; 17. Control room application; 18. Automation System, M2M; 19. GSM Access Control System, GSM Gate Opener, etc. 2.Safety Directions Safe Startup Do not use GSM RTU when using GSM equipment is prohibited or might bring disturbance or danger. Interference All wireless equipment might interfere network signals of GSM RTU and influence its performance. Avoid Use at Gas Station Do not use GSM RTU at a gas station. Power off RTU when it near fuels or chemicals. Power it off near Blasting Places Please follow relevant restrictive regulations. Avoid using the device in blasting places. Page 3 of 17 King Pigeon Hi-Tech. Co., Ltd. Page 3 of 17 Ver 1.1 File No.:KPRTU500011
4 Reasonable Use Please install the product at suitable places as described in the product documentation. Avoid signal shielded by covering the mainframe. Use Qualified Maintenance Service Maintenance can be carried out only by qualified maintainer. 3. Standard Packing List Control Unit X1, GSM ANT X1, User Manual X1(CD), Serial cable for communication X 1 (RS232). Optional Accessories: (Wired Sensors) PIR Motion Sensor, Glass Break Sensor, Magnetic Window Sensor, Temperature Sensor, Infrared Beam Fence, Vibration sensor, Water level sensor, Siren, etc. 4. Physical Layout 4.1 Control Unit physical layout LED Instruction CHG REG Charge the backup battery will on, otherwise will off. GSM register indicator, quickly flick means registering the gsm network, slowly flick means finished the registration. Page 4 of 17 King Pigeon Hi-Tech. Co., Ltd. Page 4 of 17 Ver 1.1 File No.:KPRTU500011
5 SMS RUN In initializing while power on, will always on. After initialized will off. When send out SMS, will on. In initializing while power on, will always on. After initialized will flick on slowly. Interface 1 Instruction ANT SIM BAT SW GSM Module Antenna. SIMCard Slot. Backup battery Switch Interface 2 Instruction POWER GND IN1+ IN1- IN2+ IN2- IN3+ IN3- IN4+ IN4- OUT+ OUT- AD/RXD Power Connector, Connect to the power source. Ground point, connect to power negative electrode, and COM point for AD,OC. Opt coupler (ISO) Input 1; connect to one wire of the wired Detector or positive electrode. Opt coupler (ISO) Input 1; connect to another wire of the wired Detector or negative electrode. Opt coupler (ISO) Input 2; connect to one wire of the wired Detector or positive electrode. Opt coupler (ISO) Input 2; connect to another wire of the wired Detector or negative electrode. Opt coupler (ISO) Input 3; connect to one wire of the wired Detector or positive electrode. Opt coupler (ISO) Input 3; connect to another wire of the wired Detector or negative electrode. Opt coupler (ISO) Input 4; connect to one wire of the wired Detector or positive electrode. Opt coupler (ISO) Input 4; connect to another wire of the wired Detector or negative electrode. MOSFET Relay output ; connect to the device positive electrode or one wire of the relay.(optional) MOSFET Relay output; connect to the device negative electrode or another wire of the relay.(optional) Analog input and RS232 RXD Point, connect to Analog detector or RS232 Cable RXD wire. OC/TXD OC Drive Output and RS232 TXD Point, connect to device positive or RS232 Cable TXD wire. 5. Features 1 MOSFET Relay output, Current Drive ability note: >100mA, Patient Voltage note: 60V. It can be switched on by sending a SMS to the unit. Output mode: pulse. Outputs trigger by SMS commands, the width and the period of the pulse can also be set.(optional,if you want to use it please buy the AQY22 R S from Panasonic.) 2 1 OC Drive Current: >500mA (continuous). Output mode: pulse. Outputs trigger by SMS commands, the width and the period of the pulse can also be set. 3 1 AD channel: 0-5V, 8Bits, Input Impedance: 50KOhm. If AD input value is higher than the setting higher value, or If AD input value is less than the setting lower value, the unit will be activated. 4 4 Opt coupler (Iso) Input, Input Drive Current: Min:0.5mA, Max:45mA (continuous), Reverse Patient Voltage: 100V; Can setup as rising edge or failing edge or both the rising edge and the failing edge will activate the RTU. Page 5 of 17 King Pigeon Hi-Tech. Co., Ltd. Page 5 of 17 Ver 1.1 File No.:KPRTU500011
6 5 4 of the 4 Opt coupler (Iso) can be used as Counter Function, multiplexed counter channel, the falling edge and the rising edge of it will be invalid. The channel can be activated by a pre-setting value (time or quantity). If there is overflow, it will loop. 6 When System initialization complete (by power supply or battery), will send the SMS to SMS recipient 1. 7 When power supply on, while supported by back-up battery, will send the SMS to SMS recipient 1. 8 If there is built in battery, RTU detects that the power level is lower than the pre-setting lower value, the event will be activated. 9 If the power supply disconnected or power off, the RTU will send SMS to SMS recipient Up to 4 mobile phones numbers can be pre-set as SMS Alarm number. 11 Up to 4 phones numbers can be pre-set as auto dialing Alarm number. 12 Password protected, prevents unauthorized user; 13 Can be set up and programmed from any GSM phone or PC through RS232 Cable; 14 Time stamped alarm messages. 15 Based on GSM Network. 6. Settings The GSM SMS Controller is for user-friendly design. The user can setup it by the PC programmer through RS232 Serial cable. 6.1 Setup through the PC Programmer Tips! 1) Please insert the SIMCard firstly, and install the GSM Antenna, please power on to check the LEDs can work or not, then power off it before you program it by PC Programmer. 2) The default password is 1234, you can modify it by enter the new password in the PC Programmer. 3) Must setup the SMS recipient 1 number. 4) The RXD and TXD point will communicate the computer within 1Second after initialization, if it can create the communication to the Computer, then will work with the computer, if can not receive signal from computer, then will automatically change to AD and OC function. 5) The connections of the RS232 cable to communication with the Computer is below: Page 6 of 17 King Pigeon Hi-Tech. Co., Ltd. Page 6 of 17 Ver 1.1 File No.:KPRTU500011
7 The PC Programmer Interface Please following the below steps one by one to setup it, otherwise you cannot setup it successfully. Step1: Please insert the CD one your computer firstly; Step2: Please insert the SIMCard into the GSM SMS Controller carefully; Step3: Please running the PC Programmer, needn t installed it; Step4:Please connect the GSM RTU5000 to the computer through RS232 cable, but please don t switch on the GSM RTU5000, otherwise, the setup will be failure; Step5: Please setup the GSM RTU parameters as 6.1.1; Step6:After you finished the setup, then press Download button then switch on the GSM RTU, after 2Seconds, it will alert the Setup successful. Step 7: Power off the unit then remove the RS232 cable. Then power on the Unit to finish the setup. If it hasn t prompted the setup successful, then means the setup is failure, please check the Com port and RS232 connection, then try to repeat the Step1~Step6 again Setup the parameters 1) SMS Recipient 1-4 and Phone Call Recipient 1-4 The recipients number: A maximum of 16 digits or +. If there is country code, + must be added at the head. For each item, it can accept Max. 4 SMS recipient mobile-phone numbers and 4 call recipient telephone numbers. In the areas where there is delay for sending SMS, RTU solves this problem by making calls, after sending SMS to chosen numbers, RTU will call the pre-set telephone number. Page 7 of 17 King Pigeon Hi-Tech. Co., Ltd. Page 7 of 17 Ver 1.1 File No.:KPRTU500011
8 SMS Recipient: when the RTU is triggered by input, counter or alert of power down (or battery low under limit), SMS will auto-send to the recipients number. Set up the recipients of the SMS at the SMS Settings section. For each event, there are recipients to set, 4 numbers at most. The First SMS Recipient must be setup in valid. Phone call Recipient: when the RTU is triggered by input, counter or alert of power down(or battery low under limit ), RTU will auto-call to the recipients number and hung up, leaving a miss number. The recipient telephone number can be setup at the Telephone Settings section. Call auto-hang up time can be set at: Dial delay (10-30secs) In some GSM operators they use different SMS protocols, if the unit can t return the SMS confirmation is normally. It is not product problem. Also, you can try to add the country code before the number, see the below settings: For example: In China, the country code is +86, or The user cell phone number is and has been assigned as a SMS Alert number; the simcard number in the panel is Problem 1: Alarm but the user hasn t received the SMS Alert. Solution: Please plus the country code while you setup the as SMS Alert number, means setup to instead of the Problem 2: The user number can receive the SMS Alert message from alarm panel, but the alarm panel cannot receive the commands from the user number. Solution: Please add country code to the SIMCard number in the alarm panel. Means send sms commands to to instead of Solution 3: When you use cell phone dial another one, what number it will be displayed then you can set the displayed number as dial numbers; when you use cell phone send SMS to another cell phone, what number it will be displayed then you can set the displayed number as SMS Alert number, just use the + to replace the 00, also, you can try the 00. 2) Input The four Input channels: IN1+/-; IN2+/-; IN3+/-; IN4+/- and there are four factors that can activate the RTU. Both the rising edge and the failing edge can activate the RTU. 1) Choosing the triggering channel: IN1+/-; IN2+/-; IN3+/-; IN4+/- 2) Choosing the triggering mode: on IN1-4 > rising edge > failing edge > rising and failing edge 3) Edit the SMS content replying on SMS Content: IN1-4 Rising/Falling Edge : The content of each event, no longer than 32 characters. 4) Choosing the SMS Recipient and Phone call Recipient For example: if SMS are to be sent to Rep1 and Rep3 through channel 1, TEL1 and TEL3 are to be clicked on IN1 SMS Recipients. Page 8 of 17 King Pigeon Hi-Tech. Co., Ltd. Page 8 of 17 Ver 1.1 File No.:KPRTU500011
9 IN1+/-; IN2+/-; IN3+/-; IN4+/-: when choose Counter Function, these inputs can be used as multiplexed counter channel, the falling edge and the rising edge of them will be invalid. The channel can be activated by a pre-setting value (time or quantity). If there is overflow, it will loop. Switch back battery on to save the value having counted. Period send: When time up the RTU will report the value via SMS to recipients, after reporting the counter will not reset to zero. when counting to , auto reset to zero. 1) Choose Counter Function >> Period send, the inputs will count input trigger (or pulse), send the data periodically if clicked. 2) The period is set at timer ; min is 1Minutes; max is 65535Minutes; 3) Choosing the SMS Recipient and Phone call Recipient of the channel. If you setup period send of IN1, IN2, IN3, IN4 Event and set the time 60mins, then after 60mins, The RTU5000 will send SMS as below format: C1=nnnnnn; C2=nnnnnn; C3=nnnnnn; C4=nnnnnn; to recipients. nnnnnn indicates counting value, value range is , when counting to , auto reset to zero. For example: A. You input C1= at IN1 counter, C2= at IN2 counter, C3= at IN3 counter, C4= at IN4 counter, and select period send function on IN1,IN2,IN3,IN4 event, Then modem will send SMS like C1=nnnnnn; C2=nnnnnn; C3=nnnnnn; C4=nnnnnn; to recipients. B. You input CAFEO at IN1 counter, blank at IN3 counter, and select period send function on IN1, IN3 event, Then modem will send SMS like CAFEOnnnnnn; nnnnnn; to recipients. (Note: The recipients number is decided by IN3 recipients only, it means the period send number is according to IN3 setting) Value send: After the counter counts to the preset value, RTU will be activated to send SMS to recipients and then the counter will reset to zero automatically. 1) Choose Counter Function >> Enable preset, If choose, the Inputs will count trigger (or pulse), when counts to the preset value, RTU will be activated to send SMS to recipients 2) The value is set on Preset Num range is 1~ ) Edit the SMS content replying on SMS Content: Counter.The content of each event, no longer than 32 characters. 4) Choosing the SMS Recipient and Phone call Recipient of the channel. Sampling Interval: range 0-255; unit: ms When set interval is 0, sampling frequent: 10khz When the interval is 1, sampling period is 1ms, sampling frequent is 1000Hz, input inplus less than 500Hz When the interval is 100, sampling period is 100ms, sampling frequent is 10Hz, input inplus less than 5Hz Testing: connect a signal generator to IN3 channel. and also can use port switch board to send the serial data. 3) Output There are two output channels: MOSFET Relay output (OPTO) and OC gate Output. Output mode is Pulse Outputs trigger by SMS commands: Send or Stop sending or Send designated numbers of pulses. The width and the period of the pulse can also be set. OPTO Pulse Width : the width for OPTO output pulse, unit is 10ms Page 9 of 17 King Pigeon Hi-Tech. Co., Ltd. Page 9 of 17 Ver 1.1 File No.:KPRTU500011
10 OPTO Pulse Period : the period for OPTO output pulse, unit is 10ms OC Gate Pulse Width : the width for OC output pulse, unit is 10ms OC Gate Pulse Period : the period for OC output pulse, unit is 10ms 4) AD Input Detecting The max sampling data of AD is 255, it corresponds input is 5V. There are three events can trigger AD function: if active the AD Event, but without AD input, the value of voltage of AD is 0V. Over limitation: If AD input value is higher than the setting higher value, the event will be activated. 1) Choose the Over limitation ; 2) Fill value in Higher value. 3) Edit the SMS content replying on AD Over Limitation : The content of each event, no longer than 32 characters. 4) Choosing the SMS Recipient and Phone call Recipient the alert SMS reports once every 5mins Under limitation triggering: If AD input value is less than the setting lower value, the event will be activated. 1) Choose the Under limitation ; 2) Fill value in lower value. 3) Edit the SMS content replying on AD Under Limitation : The content of each event no longer than 32 characters. 4) Choosing the SMS Recipient and Phone call Recipient the alert SMS reports once every 5mins Period sampling value send: If Period Send is clicked, RTU will send the AD input sampling value periodically. 1) Choose the Period Send ; 2) Set the time interval of sending the AD value on Timer. the min is 10 seconds 3) Choosing the SMS Recipient sending SMS content:ad=xxx xxx indicate AD Sampling voltage value, value range is (0-5V) 5) Battery event: if the RTU detects that the backup battery power level is lower than the pre-setting lower value, the event will be activated. 1) Choose the Under limitation ; 2) Fill value in lower value. (> 153: equal to 3.6v) 3) Edit the SMS content replying on Battery Under Limitation : The content of each event no longer than 32 characters. 4) Choosing the SMS Recipient and Phone call Recipient when the battery is low about 3.4V, the device stop working. So the battery lower value should above Formula of Battery voltage: LowValue= battery voltage/6*255 = 42.5 * battery voltage. 2. The alert SMS reports once every 10 mins Page 10 of 17 King Pigeon Hi-Tech. Co., Ltd. Page 10 of 17 Ver 1.1 File No.:KPRTU500011
11 6) RTU Initok A. System initialization complete (by power supply or battery), send the SMS to recipient 1. B. Report when power supply on, while supported by back-up battery, send the SMS to recipient 1 Edit the SMS content replying on RTU Initok. the initok SMS only report to recipient 1 7) Power down: When the power supply disconnected or power off, the RTU will send SMS to recipient 1 Edit the SMS content replying on RTU Power down. The power down SMS only report to recipient 1 8) Password: Four digits ASCII code. 9) Com Port Select the Com port to communicate between GSM SMS Controller and Computer. 10) Download Download the settings from computer to GSM SMS Controller. The Serial Port Status turns to green; Communication begins to flash 11) Upload Upload the settings from GSM SMS Controller to computer. 12) Save Save the settings to computer. 13) Read Read the settings from the Saved file in the computer. 14) Stop Stop the communication between the computer and GSM Controller. 7. Operating Instructions The GSM RTU can support SMS Commands. The SMS Commands are below: The system will carry out the commands immediately (with no delay) after the Control Unit receive this SMS command. 7.1 Modify PASSWORD xxxxennnn xxxx stands for the old password (1-4 digits). nnnn stands for the new password Return SMS Change Password Ok! 1. xxxx refers old Password; nnnn is new Password. It is constituted by 4 ASCII codes. 2. Factory default:1234. Page 11 of 17 King Pigeon Hi-Tech. Co., Ltd. Page 11 of 17 Ver 1.1 File No.:KPRTU500011
12 3. The password is case sensitive 7.2 Set up SMS recipients by SMS : Max 4 recipients xxxxraaaaaaaaaaa ; bbbbbbbbbbbb;cccccccccccc;ddddddddd# xxxx stands for the password (1-4 digits). Return SMS Change Recipients Ok! Change or Cancel recipients: Re-set with new recipients. After sending the SMS, the setting contents will be instead to the last time 1. aaaaaa, bbbbbbbbbbb indicates the recipients mobile phone number ASC or digits. 2. the numbers are spaced between ; 3. +country code must be added when SMS format requires 4. SMS Format: + Country Code and mobile phone number. 5. R in the SMS format must be capitalization Exp: setting Recipients: Sending SMS: 1234R ; ; # or xxxxr ;+45679;45646;45646#123 (the num after # are invalid) Setting successfully: Change Recipients Ok! 7.3 Set up Auto-call recipients by SMS : Max 4 recipients xxxxteeeeeeeeee;fffffffffffff;ggggggggggg;hhhhhhhhhhhhhhh# xxxx stands for the password (1-4 digits). Return SMS Change Recipients Ok! Change or Cancel recipients Re-set with new recipients. After sending the SMS, the setting contents will be instead to the last time 1. eeeeeeeee, hhhhhh indicates the recipients mobile phone or PSTN number ASC or digits. 2. the numbers are spaced between ; 3. +country code must be added when SMS format requires 4. SMS Format: + Country Code and mobile phone number. 5. T in the SMS format must be capitalization Exp: setting Recipients: Sending SMS: 1234T ; ; # or xxxxt ;+45679;45646;45646#123 (the num after # are invalid) Setting successfully: Change Recipients Ok! 7.4 Delay after auto-dialing (for leaving missing call to recipients) Page 12 of 17 King Pigeon Hi-Tech. Co., Ltd. Page 12 of 17 Ver 1.1 File No.:KPRTU500011
13 xxxxdtnn# xxxx stands for the password (1-4 digits). Return SMS Change Dial Delay Ok! 1. nn indicates the delay after device call recipients,unit: second,range: The default configure is 10secs. 7.5 Input(Counters) A. Reset the counter to zero by SMS: B. Period send method: When inputs were used as Period send channel, the RTU will send to pre-setting recipients the SMS: xxxxcc xxxx stands for the password (1-4 digits). Return SMS Clear counter Ok! C1=xxxxxx;C2=xxxxxx;C3=xxxxxx;C4=xxxxxx xxxxxx: indicates the counting value at that time, the range of counting is , when counting to , auto clear to zero. C. Fixed Value send method When inputs were used as value trigger channel, the RTU will send to pre-setting recipients the SMS: xxxxscnnnnnn# nnnnnn# nnnnnn# nnnnnn# xxxx stands for the password (1-4 digits). Return SMS Set Precounter Ok! 1. nnnnnn: Pre-setting count amount; the range is ; 2. SMS format: xxxxsc1000# or xxxxsc50# are valid; 3. Count amount will not be lost after power off, save by working of battery. When pulses from the sensor reach the pre-setting value, the GSM RTU send SMS to recipients: nnnnnn 1. nnnnnn: indicates the counting value at that time, the range of counting is ; 2. the counter will reset to zero automatically after reporting SMS, and then counts repeat; 3. The value have counted will not be lost if power off (supported by battery). 7.6 AD: Trigger AD to Period Send, the RTU will send the voltage sampling value periodically to pre-setting recipients Page 13 of 17 King Pigeon Hi-Tech. Co., Ltd. Page 13 of 17 Ver 1.1 File No.:KPRTU500011
14 the SMS: ADC=xxx xxx: indicates the voltage value at that perod, the range of is Query AD xxxxqa xxxx stands for the password (1-4 digits). Return SMS C=xxx 7.7. OC output channel setup There is OC gate for output. SMS commands can be used to enable the output. And SMS commands can designate the numbers of impulse to be sent. xxxxocpaa xxxx stands for the password (1-4 digits). Return SMS Set OC Ok! 1. aa: output pulse times; setting range is 01-99; 2. pulse width/period: are optional. 3. when aa=00 the SMS unit send pulse constantly till send OCR to stop it. 7.8 OPTO Output Port (MOSFET relay): OUT+/OUT- 1. aa: output pulse times; setting range is 01-99; 2. pulse width/period: are optional; 3. when aa=00 the SMS unit send pulse constantly Page 14 of 17 King Pigeon Hi-Tech. Co., Ltd. Page 14 of 17 Ver 1.1 File No.:KPRTU500011
15 7.9 Wrong Message: When the PWD is right, but the format of the SMS command invalid, you will receive the prompt SMS: Format Error! 8. Installation Before installing the control unit and sensors, please help to test the system firstly, including wired sensor, power supply, gsm signal, etc. 8.1 Insert SIMcard into Control Unit In the backside of the control unit, please install the GSM SIM card installation to ensure it in good working condition.. The GSM ANT must be Vertical 8.2 Connecting the Wired Sensors or outputs Please help to see below wiring diagram, then fixed the related wired sensors, the sensors connect to the related inputs. Please help to ask an engineer to contact them. 8.3 Install the Mainframe The mainframe should be installed in the position that person can not get it, and there re with a power source as well as enough GSM signal coverage. 9. Technical specifications Parameter item GSM Frequency DC Power supply Reference scope Default: 900/1800/1900Mhz, Optional: 850/1900/1800/1900Mhz Standard adapter: DC 12V/1.5A Min:7.5V Max:25V Type:12V Power Current Max:500mA Type :50mA SIM Card Supporting 3V SIM Card 50 Ω SMA Antenna interface, GSM Antenna Cable type: Gain:3dBi cable-length:3-5meters connector :SMA Portable antenna: Gain:2dBi height: 5cm connector: SMA Page 15 of 17 King Pigeon Hi-Tech. Co., Ltd. Page 15 of 17 Ver 1.1 File No.:KPRTU500011
16 Serial Input Type RS-232C, Default communication parameter 9600,n,8,0,1 4 Opt coupler (Iso) Input Drive Voltage Min:2.5V Max:48V, Input Drive Current Min:0.5mA Max:45mA (continuous) Input Reverse Patient Voltage Opt coupler (Iso) Output Current Drive ability Opt coupler (Iso) Output Patient Voltage Range of AD Voltage AD Input Digit 100V >100mA 60V Max: 50V Typ:0-5V 8BIT AD Input Precision +/- 2% AD Input Impedance OC Drive Current Exterior dimension Backup-battery: 50KOhm >500mA (continuous) 110x85x23mm 3.7V 950MAh LI-ION Temperature range -20 C ~ +60 C Humidity range Weight Relative humidity 20~95% (condensation free) 130 g ** Electrical C 10. Warranty 1) This system is warranted to be free of defects in material and workmanship for one year from the date of purchase. 2) This warranty does not extend to any defect, malfunction or failure caused by abuse or misuse by the Operating Instructions. In no event shall the manufacturer be liable for any alarm system altered by purchasers. 11.Trouble Shooting Guide PROBLEM CAUSE POSSIBLE SOLUTION GSM Module 1) Backup battery with low voltage; 1) Please contact the AC Power; initialization failed GSM Module connection loose in transportation; 2) GSM Signal is too weak. 2) Please help to take the panel to a mobile phone repairmen store, and then ask the engineer to check the GSM Module socket and the GSM Module connection; 3) Please change another position to install the alarm panel. Automatically Restart False Alarm 1) Backup battery with low voltage. 1) Raising and failing setting is incorrect. 1) Please help to contact the AC Power. 1) Please check the input type. Page 16 of 17 King Pigeon Hi-Tech. Co., Ltd. Page 16 of 17 Ver 1.1 File No.:KPRTU500011
17 Alarm without SMS or Dial/ No action after send SMS command 1) GSM Operator communication protocol; 2) Haven t setup SMS Alert/Auto dial Numbers. 3) Caps Lock letters in the SMS Commands. 1) Please setup the SMS Alert Numbers; 2) Please help to see the sample of setup the telephone numbers; 3) Please check the commands with CAPS LOCK and correct format. 4) Also, please help to change another GSM Operator SIMCard to test it. The End! Any questions please help to contact us feel free. Us: [email protected] Page 17 of 17 King Pigeon Hi-Tech. Co., Ltd. Page 17 of 17 Ver 1.1 File No.:KPRTU500011
GSM SMS Controller GSM SMS Alarm Unit S130 S140 S150. User Manual
Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone! GSM SMS Controller GSM SMS Alarm Unit S130 S140 S150 User Manual Ver
GSM Gate Opener GSM Remote Switch RTU5015. User Manual. Ver 1.3 Date Issued: 2010-08-18. All rights reserved by King Pigeon Hi-Tech. Co., Ltd.
GSM Gate, Barrier, Shutter, Garage Door and Door opener Open gate or garage door with a FREE call from your mobile phone! Remote switching machines with a FREE call from your mobile phone! GSM Gate Opener
GSM Gate Opener GSM Remote Switch RTU5015 User Manual
GSM Gate, Barrier, Shutter, Garage Door and Door opener Open gate or garage door with a FREE call from your mobile phone! Remote switching machines with a FREE call from your mobile phone! GSM Gate Opener
GSM Gate Opener GSM Remote Switch RTU5015. User Manual. Ver 1.1 Date Issued: 2009-12-18. All rights reserved by King Pigeon Hi-Tech. Co., Ltd.
GSM Gate, Barrier, Shutter, Garage Door and Door opener Open gate or garage door with a FREE call from your mobile phone! Remote switching machines with a FREE call from your mobile phone! GSM Gate Opener
GSM Elderly Guarder. User Manual. Ver 1.1 Date Issued: 2012-06-20. All rights reserved by Shenzhen Daiya Electronic Technology Co., Ltd.
GSM Elderly Guarder User Manual Ver 1.1 Date Issued: 2012-06-20 All rights reserved by Shenzhen Daiya Electronic Technology Co., Ltd. Website: Page 1 of 17 Shenzhen Daiya Electronic Technology Co., Ltd.
GSM Gate Opener GSM Remote Switch
GSM Gate, Barrier, Shutter, Garage Door and Door opener Open gate or garage door with a FREE call from your mobile phone! Remote switching machines with a FREE call from your mobile phone! GSM Gate Opener
GSM SMS IR CONTROLLER
Automatically monitoring Air Conditioner by SMS Text! Remotely Control Air Conditioner by SMS Text! Temperature Monitoring by SMS Text! GSM SMS IR CONTROLLER RTU5016 User Manual Ver 1.0 Date Issued: 2012-03-05
GSM Elderly Guarder User Manual Ver 1.0 X-TRON
GSM Elderly Guarder User Manual Ver 1.0 X-TRON Page 1 of 18 X-TRON Page 1 of 18 Ver 1.0 File No.:XT-EASX001 Table of Contents 1. Brief introduction -------------------------------------------------------------------3
GPRS M-Bus Master. User Manual. An Economical and Practical Solution For Remote Automactic M-Bus Smart Meter Reading by GPRS In The Worldwide!
An Economical and Practical Solution For Remote Automactic M-Bus Smart Meter Reading by GPRS In The Worldwide! GPRS M-Bus Master User Manual Mx Series Ver 1.00 Date Issued: 2015-07-28 All rights reserved
GSM House Alarm System. S110 User Manual. Ver 1.00 Date Issued: 2010-09-01
GSM House Alarm System S110 User Manual Ver 1.00 Date Issued: 2010-09-01 All rights reserved by King Pigeon Hi-Tech. Co., Ltd. Website: Http://www.GSMalarmsystem.com Table of Contents 1. Brief introduction
GSM Alarm System User Manual
GSM Alarm System User Manual For a better understanding of this product, please read this user manual thoroughly before using it. Quick Guider After getting this alarm system, you need to do the following
SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision 090210 [Version 2.2]
SMS Alarm Messenger SMSPro_Setup Revision 090210 [Version 2.2] ~ 1 ~ Contents 1. How to setup SMS Alarm Messenger?... 3 2. Install the SMSPro_Setup software... 5 3. Connection Type... 6 4. Connection Port
Intelligent GSM Auto-dial Alarm System User s Manual
Intelligent GSM Auto-dial Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. [Function Instruction] [Control Panel Introduction]
DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com
DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com This handbook has been designed as a guide to the installation and operation of King Pigeon Hi-Tech.Co.,Ltd DAM series. Statements
Business/Home GSM Alarm System. Installation and User Manual
Business/Home GSM Alarm System Installation and User Manual Brief Introduction: GSM 900/1800/1900 bands, can be used in most parts of the world Full duplex communication with the host Monitor the scene
GSM ALARM SYSTEM USER MANUAL
GSM ALARM SYSTEM USER MANUAL 1. Instruction The alarm system is based on GSM network. With a GSM SIM card, it can be used wherever you want and no need to connect any wire, which is convenient and easy
GSM HOME SECURITY SYSTEM
Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.
Business/Home. GSM Alarm system
Business/Home GSM Alarm system Installation and Users guide Profile For a better understanding of this product, please read this user manual thoroughly before using it. I. General information: GSM 900/1800/1900
New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.
New GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Chapter 1. Features Chapter 2. Alarm Host Introduction Chapter
GPS Vehicle and personal location tracker. User manual
GPS Vehicle and personal location tracker User manual 1 Contents 1. Product overview... 2 2. Safety instruction... 3 3. Specification and parameters... 3 4. Getting started... 4 4.1 Hardware and accessories...
STATUS POWER MONITOR ALARM SOS DISARM
STATUS POWER MONITOR ALARM SOS DISARM I. Features II. Preparation before use III. Host 1.LED status explanation 2. Host panel IV. System Settings 1. Coding of wireless sensors 2. Exit coding 3. Settings
CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual
CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CGWTS-M001A Version 1, Release 1, December 2004 NOTICE
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO
GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module
S100. GSM House Alarm System. Http://www.GSMalarmsystem.com
S100 GSM House Alarm System Http://www.GSMalarmsystem.com 1. Brief introduction The GSM Alarm System is a new security protection solution special for home, house and office and other applications. It
Falcon Protector Tracking System
Falcon Protector Tracking System Product Overview The Falcon Protector is a GPS and GSM tracking device which is specially developed and designed for vehicle tracking. With the latest SIFR III GPS module
Wireless Auto-dial Intruder Alarm System
Wireless Auto-dial Intruder Alarm System User Manual User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Features and Function 1.
Business/Home GSM. Alarm System(III) Installation and Users guide
Business/Home GSM Alarm System(III) Installation and Users guide I. General information: GSM 900/1800/1900 bands, can be used all over the world. Full duplex communication with the base. Monitor environment
SMS GSM Alarm Messenger
SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited
(Rev. 1.0) China Aerospace Telecommunications Limited Contents 1. Introduction......3 2. Specifications...4 2.1 External Interface... 4 2.2 Status Indicator...... 5 2.3 Technical Parameters... 6 3. Device
Business/ Home GSM Alarm System
Business/ Home GSM Alarm System BUSINESS/HOME GSM ALARM SYSTEM POWER STATUS RECORD SIGNAL User Manual Profile For a better understanding of this product, please read this user manual thoroughly before
TX GSM SMS Auto-dial Alarm System. Installation and User Manual
TX GSM SMS Auto-dial Alarm System Installation and User Manual Product Features: 1. 16 wireless zones, 3 wired zones alarm system, suitable for small to medium size offices and homes. 2. The system uses
Six-defense zone Display Alarm System. User Manual
Six-defense zone Display Alarm System User Manual Feature 1. Anti-interfere function. When someone interferes it with same frequency, the control unit will activate siren to alarm. 2. Support anti-decode
The A10 GSM Elderly Guarder is a very innovative concept of GSM Panic Alarm, GSM
Model: A10 Name: GSM Elderly Guarder The A10 GSM Elderly Guarder is a very innovative concept of GSM Panic Alarm, GSM Emergency Call System and GSM Medical Alarm System. I can call my Son by just press
Car Alarm Tracker Manual-20150814
CCTR-922 Car Alarm Tracker Manual-20150814 Welcome to use this GSM car alarm with tracker function CCTR-922. this product use 2G GSM network (LBS locate) to locate the car, it has many new and unique functions,
WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide
WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide Version 2.1, 4/2010 Disclaimer While every effort has been made to ensure that the information in this guide is accurate
CCTR-805-V2 3G Car GPS Tracker-201604
CCTR-805-V2 3G Car GPS Tracker-201604 Welcome to use this real time car GPS tracker CCTR-805G.This product is with GPS module and 2G GSM / 3G WCDMA module (with LBS locate without GPS), that has many new
GSM home alarm system s manual
GSM home alarm system s manual I. Main features: 1, Eight wireless LED zone, and four wired zone 2, Two-way to communication 3, The system supports the GSM cell phones, no need the fixed telephone line.
In The Worldwide! GSM Elderly Care Alarm Telecare & Telehealth System. User Manual. An Advanced Programmable Multifunctional Elderly Care Alarm
An Advanced Programmable Multifunctional Elderly Care Alarm In The Worldwide! T2 GSM Elderly Care Alarm Telecare & Telehealth System User Manual Ver 1.0 Date Issued: 2015-05-01 All rights reserved. King
An Advanced Programmable Multifunctional GSM Auto-Dialer GSM Alarm Panel In The Worldwide!
GSM Security Alarm GSM SOS Call System An Advanced Programmable Multifunctional GSM Auto-Dialer GSM Alarm Panel In The Worldwide! K2 User Manual Ver 1.1 Date Issued: 2013-02-01 All rights reserved. Index
GSM AUTO DIALER. Remote Monitoring & Control using your mobile phone. www.gsm-activate.co.uk
GSM AUTO DIALER Remote Monitoring & Control using your mobile phone www.gsm-activate.co.uk Product Information Our GSM Auto-Dialer is a versatile unit which can be attached to many of your electronic devices
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
GSM Alarm. An Advanced Programmable Multifunctional GSM Auto Dialer GSM Alarm Panel In The Worldwide! User Manual. S100Pro. Ver 1.
An Advanced Programmable Multifunctional GSM Auto Dialer GSM Alarm Panel In The Worldwide! GSM Alarm User Manual S100Pro Ver 1.0 Date Issued: 2013-09-01 All rights reserved by King Pigeon Hi-Tech.Co.,Ltd.
Users Manual of GSM Home Alarm System with Photo-taken
GSM-IV REMOTE CAMERA MANNAL The Excellent GSM + Camera alarm system bases on the GSM network, integrates the communication technology, can automatic screen a photo with the intruder or burglar, and send
Intelligent GSM Auto-Dial Alarm System
Auto-dial Alarm System Intelligent GSM Auto-Dial Alarm System Profile For a better understanding of this product, please read this user manual thoroughly before using it. 2013.2.V1.0 Auto-dial Alarm System
GSM Home Alarm System User Manual. http://www.usmartbuy.com
GSM Home Alarm System User Manual http://www.usmartbuy.com 1 1. Factory default Normally, all sensors in the big box have been coded (learnt) to the control host Operation Password: 0000 Long-Distance
F2103 GPRS DTU USER MANUAL
F2103 GPRS DTU USER MANUAL Add:J1-J2,3rd Floor,No.44,GuanRi Road,SoftWare Park,XiaMen,China 1 Zip Code:361008 Contents Chapter 1 Brief Introduction of Product... 3 1.1 General... 3 1.2 Product Features...
GSM ATT Modules Simply effective remote control
GSM ATT Modules Simply effective remote control To control electrical loads via mobile phone The benefits Remote management of electrical devices is an increasingly widespread requirement in residential
GSM AUTO-DIALER With 10Amp Relay USER GUIDE
GSM AUTO-DIALER With 10Amp Relay USER GUIDE GSM Frequency: Quad band freq 850/900/1800/1900 MHz Power Supply Voltage: 9-18Vdc 1Amp max Current used in standby mode: 25mA max IP 65 Enclosure rating for
Intelligent Alarm System
Intelligent Alarm System User Manual Ver 12-3 Dear users, Thank you for having selected the intelligent alarm system. Please read through this manual before installation so as to operate properly. The
Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)
CN2HK LIMITED Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003) User Manual Please read this manual before operating this product. After you finish reading this manual,
SMS Alarm. User Manual
SMS Alarm User Manual 1 1. Introduction... 2 2. SMSA1000 Specifications... 3 3. Parts Identifications... 4 4. Packing Contents... 5 5. Battery and SIM Card Installation... 6 5.1 Open the Back Cover...
Temperature & Humidity SMS Alert Controller
Temperature & Humidity SMS Alert Controller Version 7 [Windows XP/Vista/7] GSMS THR / GSMS THP Revision 110507 [Version 2.2.14A] ~ 1 ~ SMS Alarm Messenger Version 7 [Windows XP/Vista/7] SMS Pro series
LW-2000-3A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets
LW-2000-3A Wireless Auto Dial Alarm System Sentry Plus User Manual By Global Gadgets Main Features Simple to use keypad for operation and control. The system can store up to 9 telephone numbers: positions
Home Security Alarm System
Home Security Alarm System User Manual (ALM-S02) Read manual carefully before use. PiSector Inc., USA www.pisector.com Thank you for purchasing this home security alarm system. For your safety and better
GSM SMS GPRS Remote Controller GPRS Data Logger GSM GPRS RTU
Send SMS Text Message to your Mobile Phone when alarm occurrence! Remote Monitoring Your Outdoor Assets In Anywhere and Anytime! GSM SMS GPRS Remote Controller GPRS Data Logger GSM GPRS RTU User Manual
DC-8706K Auto Dial Alarm System
DC-8706K Auto Dial Alarm System User Guide Basic Contents: 1x the host unit; 1x wireless door (window) magnet; 1x wireless infrared detector; 2x remote control; 1x siren; 1x phone core; 1x AC to DC power
Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS
Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti theft Alarm System Overview 1. GPS data tracking via GSM
GSM WIRELESS DIGITAL ALARM SYSTEM USER GUIDE. Please read it carefully before installation and operation
GSM WIRELESS DIGITAL ALARM SYSTEM USER GUIDE Please read it carefully before installation and operation Your New Diamond Designs Alarm works with a GSM SimCard via the cellular phone,system to call up
CCTR-800 Portable Real Time GPS Tracker
CCTR-800 Portable Real Time GPS Tracker Welcome to use Real Time GPS tracker CCTR-800, This product is with GPS module and GSM module, It has many new and unique functions, such as real time uploading
GSM Voice Auto Dialer & SMS Sender JC-999
GSM Voice Auto Dialer & SMS Sender JC-999 Main features: () Large LCD display,integrated integrated keypad, human-friendly programming; (2) Support 2 alarm receiving numbers; (3) Triggering means: N.C
GSM Gate Opener Remote Relay Switch
GSM Gate, Barrier, Shutter, Garage Door and Door opener Open gate or garage door with a FREE call from your mobile phone! Remote switching machines with a FREE call from your mobile phone! GSM Gate Opener
GSM/3G UMTS/GPS/SMS Data Logger. The King Pigeon S262W S263W Data Logger inbuilt industrial GSM and 3G WCDMA
S262W S263W GSM/3G UMTS/GPS/SMS Data Logger The King Pigeon S262W S263W Data Logger inbuilt industrial GSM and 3G WCDMA module, GPS optional. channel Analog inputs (0-20mA,-20mA,0-5V) support Ultra-Low/Low/High/Ultra-High
PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.
WIRELESS AUTODIAL HOME ALARM SYSTEM AM2000 Instructions for use Important! Please read these instructions carefully. IMPORTANT 1 IDENTIFICATION PLEASE CONTACT BEFORE RETURNING THIS PRODUCT TO THE RETAILER
NavEye BlackBox GSM/GPS alarm manual
NavEye BlackBox GSM/GPS alarm manual NavEye BlackBox protects your belongings and vehicles in various ways. Equipped with external sensors the alarm can detect when a door or a hatch is opened and if the
Version:G300 V2.0 11.04. Business/Home GSM Alarm System. Installation and Users' Guide. ( 99 wireless zones)
Version:G300 V2.0 11.04 Business/Home GSM Alarm System Installation and Users' Guide ( 99 wireless zones) Brief Introduction: GSM 850/900/1800/1900 bands, can be used in most parts of the world Full duplex
User Manual. Genius GPS / GSM 810 Real Time GPS Tracker. Android App Download. Iphone App Download ENGLISH. Genius Advanced Technologies
Genius GPS / GSM 810 Real Time GPS Tracker User Manual Android App Download Iphone App Download www.geniuscaralarm.com 1 Genius GPS / GSM 810 Real Time GPS Tracker Welcome to use this real time car GPS
MANUAL PC1000R [email protected]
MANUAL PC1000R [email protected] Features The APart PC1000R is a professional multisource CD/USB/SD card music player, equipped with balanced and unbalanced analog outputs, coaxial and optical digital
Vibration Monitoring System Adash 3600
" User's guide Application: Vibration Monitoring System Adash 3600! Vibration diagnostics, monitoring and protective on-line system! On-line vibration monitoring system of engines, fans, pumps, gearboxes,
GSM Controller User manual
GSM-AUTO GSM Controller User manual INDEX Description... 2 Preparing the SIM card... 3 Installation... 4 Example connections... 5 Programming commands... 7 Quick reference of programming commands....12
HCO BG30L Mobile (GSM) Surveillance Camera/Alarm System. User s Manual
HCO BG30L Mobile (GSM) Surveillance Camera/Alarm System User s Manual Content 1 Product Information... 2 1.1 General Description....2 1.2 Interfaces... 2 1.3 Information Display... 3 1.4 Features... 4
GSMPBX version 1.3 Datasheet
GSMPBX version.3 Datasheet Document Rev.:.3 Revision Date: 23.03.203 (preliminary data) Figure - GSMPBX Introduction The GSMPBX is designed to commute phone calls between a cellular network (GSM) and the
MOBILE CALL GSM Alarm System User s Manual
MOBILE CALL GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction Alarm Host Diagram
GSM Security Alarm GSM Senior Telecare. In The Worldwide! User Manual. An Advanced Programmable Multifunctional GSM Alarm Panel GSM Senior Telecare
GSM Security Alarm GSM Senior Telecare An Advanced Programmable Multifunctional GSM Alarm Panel GSM Senior Telecare In The Worldwide! K3 User Manual Ver 1.0 Date Issued: 2014-12-01 All rights reserved.
Disturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power
Technical Manual. (TLT-2H GPS/GSM Vehicle Tracker) V1.5
Technical Manual (TLT-2H GPS/GSM Vehicle Tracker) V1.5 Product main features Real-time SMS query coordinates time position, Phone Position active help feature speed alarm function historical data uploading
DAB+ / FM Tuner Model: TU-201
DAB+ / FM Tuner Model: TU-201 Instruction Manual www.pulse-audio.co.uk 1 Safety Information The lightning bolt within a triangle is intended to alert the user to the presence of dangerous voltage levels
Fleets Vehicle GPS Tracker TS20 User Manual. (Version 1.0)
Fleets Vehicle GPS Tracker TS20 User Manual (Version 1.0) Index Contents 1. Package Contents... 3 2. Features and Specifications... 3 3. Mechanical Size... 4 4. Knowledge before Usage... 4 4.1 Factory
GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI
GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI LET S GET THIS SHOW ON THE ROAD You must be excited about your brand new Telstra Pre-Paid 3G Wi-Fi. This guide will help you get connected as quickly and
VIVA 4G LTE Mini Router. Quick Start Guide
VIVA 4G LTE Mini Router Quick Start Guide Thank you for choosing the VIVA 4G LTE Mini Router (hereinafter referred to as the E57) The supported functions and actual appearance are subject to the product
USER MANUAL V5.0 ST100
GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version
GETTING TO KNOW YOUR PRE-PAID TELSTRA WI-FI 4G
GETTING TO KNOW YOUR PRE-PAID TELSTRA WI-FI 4G LET S GET THIS SHOW ON THE ROAD You must be excited about your brand new Pre-Paid Telstra Wi-Fi 4G. This guide will help you get connected as quickly and
GSM IV Intelligent Wireless Burglar Alarm System
GSM IV Intelligent Wireless Burglar Alarm System User Manual Thanks for choosing our product,please read this manual before use it Chapter 1 Functions and Specification 1 Main functions Record 10 secs
1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3
Contents Moxa Technical Support Team [email protected] 1 Application Description... 3 1.1 Objective... 3 1.2 Goals... 3 2 System Topology... 3 3 Hardware and Software Requirements... 4 4 Configuration...
Configuring the Siemens TC35 modems for use with the MI2292
Configuring the Siemens TC35 modems for use with the MI2292 The following instruction describe how to set up GSM communication between an MI2292 Power Quality Analyser Plus and a computer 1. Equipment
WITURA CORPORATION SDN BHD
WT 1010SA Stand Alone GSM Alarm System User Manual and Installation Instructions Version: 1.2 Updated: 4 JAN 2012 WITURA CORPORATION SDN BHD Stand Alone GSM Alarm System Instruction Manual 1 Introduction:
GSM-AUTO+ GSM Controller with Internal Power Supply User manual
GSM-AUTO+ GSM Controller with Internal Power Supply User manual INDEX Description... 2 Preparing the SIM card... 3 Installation... 4 Example connections... 5 Programming commands... 6 Quick reference of
GSM Smart Switch USER GUIDE
GSM Smart Switch USER GUIDE GSM Smart Switch allows switching almost any appliance ON and OFF remotely via mobile network. It is designed to receive start/stop commands from specially coded messages or
1 0 0 1 e s p i o n s.com. V680 GPS Watch User s Manual
1 V680 GPS Watch User s Manual 2 Table of Contents Chapter I Preface..4 I.General...4 II.Notices..4 Chapter II about the Device.5 1. Appearance..5 2. Product Features.5 3. Product Specification.6 (1).Technical
EST-64 GSM Remote Control Device User Manual E E S S T T A A T T E E S S W W I I N N G G
EST-64 GSM Remote Controll Deviice User Manual EESSTTAATTEE SSWIINNGG Electronic KIT to convert your gate into a GSM gate EST-64 GSM Remote Control Device Diagram 2 1. INTRODUCTION EST-64 GSM Remote Control
PSTN Home Alarm System
PSTN Home Alarm System User Manual Model: PST-TEL99E Please read this user guide carefully before operation and installation. Contents 1. Product Overview... - 3-2. Main Function & Features... - 3-3. For
GPS Vehicle Tracker User Manual VT810
GPS Vehicle Tracker User Manual VT810 1. Please read this manual carefully for correct operation. 2. You need to ask a professional to install this product in a safe position of your vehicle. Avoid dangerous
MAGICAR M871A. Car alarm with two-way remote User s guide
MAGICAR M871A Car alarm with two-way remote User s guide EN MAGICAR M871A Car alarm with two-way remote User s guide TABLE OF CONTENTS Table of contents...2 1. Important notice...4 2. Introduction...4
HomeSafe-Basic VT-PS99E. User s Manual. PSTN Home Alarm System. Page: 1 / 15
HomeSafe-Basic VT-PS99E User s Manual PSTN Home Alarm System Page: 1 / 15 Table of Contents 1. Product Overview:... 3 2. Main Functions & Features... 3 3. For Your Safety... 4 4. VT-PS99E Characteristics...
FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS
FLEET MANAGEMENT & CAR SECURITY SYSTEM FOR PROVIDERS AND CUSTOMERS The Tracker Server Communication Program for data collection The Tracker Client Map Program intended for dispatching desks The GSM/GPRS
USER MANUAL V5.0 VT300
GPS Vehicle Tracker USER MANUAL V5.0 VT300 Updated on 26/12/2008 Contents 1 Product Overview 3 2 For Your Safety 3 3 VT300 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2 Light and
GSM/GPRS/GPS PORTABLE VEHICLE TRACER GPS104 User manual
GSM/GPRS/GPS PORTABLE VEHICLE TRACER GPS104 User manual Preface Thank you for purchasing the tracker. This manual shows how to operate the device smoothly and correctly. Make sure to read this manual carefully
Operating Instructions
Operating Instructions Kühn Controls AG, Gräfenhäuser Str. 14, D-75305 Neuenbürg, Germany Tel. +49 (0)7082-94 00 00 www.kuehn-controls.de [email protected] Fax +49 (0)7082-94 00 01 Content 1. SMS