Leak Monitoring Systems. for double-walled piping System description ENTWURF
|
|
|
- Richard Maxwell
- 9 years ago
- Views:
Transcription
1 Leak Monitoring Systems for double-walled piping System description
2 System description The leak monitoring Double-walled piping is permanently monitored using pneumatic leak detecting devices. These regulate the monitoring pressure in the sur-veillance space and register any changes of pressure which may occur. The surveillance space prevents uncontrolled spillages of the transport medium when leaks occur. The surveillance space must be so constructed that the functioning and operative security of the leak monitoring system (the leak detector) is assured at all times. The size if the surveillance space for each leak detector is limited to 10 m 3 acc. to DIN EN The use of this system complies with the most stringent European safety standards (Class 1). Systems of this class give warning of a leak above or below the fluid level in a double-walled protective system. They are constructed on the principles of absolute safety and ensure that spillages of products into the environment cannot occur. Leak detector We distinguish two types of differential pressure leak detection equipment: Leak surveillance to detect leaks in double-walled piping on the vacuum principle and on the positive pressure principle. If the pipe is damaged the alarm is given by acoustic and optical signals. Definition of leak detection equipment/leak detector Leak detection equipment/leak detector according to the currently valid regulations refers to a device which automatically and under all operating conditions gives warning of leaks in the walls of double-walled piping in which water hazardous (flammable and non-flammable) fluids are transported. The term leak detection equipment/leak detector includes all the equipment necessary for the detection of leaks. DLR-G... The main components are: - the leak detector/leak monitoring equipment - the connection between the surveillance space and leak detector) - double-walled piping: FLEXWELL Safety Pipe BRUGG-STAMANT Safety Pipe SECON -X Petrol station pipe - the surveillance space - a leak detection medium double-walled piping with vacuum leak detector 2 double-walled piping with positive pressure leak detector
3 System description Approval/suitability The advantages of the system All leak detection equipment/leak detectors in use must comply with the basic criteria laid down for construction and testing standards. All such preconditions which could have a bearing on the functional and operative safety of the system must therefore be observed. It therefore goes without saying that the conditions for operative use have been tested by the competent authorities and clearly defined and set down in the documents of approval issued by them. Double-walled piping with leak monitoring is an approved leak detection equipment/leak detector system. Using double-walled FLEXWELL Safety Pipe with leak monitoring offers, besides a high degree of operative safety, substantial economic advantages: - the entire system can be easily and simply monitored at any time without interrupting operations - requirements such as e.g. pressure/volume measurements, pressure tests or route surveys can be dispensed with - when a leak occurs, operations can normally be continued without interruption; repairs can be planned. - remote monitoring (LOD) of all operating parameters is possible (24/7). Example: a fuelling station Operating limits Each plant can be assembled to fit the needs of the individual situation by combining elements of several monitoring systems. Two-line system A monitoring lead runs from the positive pressure leak detector DLR-G 1-7 to the distributor block and from there to lines 1 and 3. - pressure range (acc. to pipe system and monitoring) - maximum monitorable pipe length see Worksheets LDS and LDS distributor block 2 8 connections filling station Ring line The double-walled pipes 1 and 2 are connected one after the other with a monitoring lead. A test valve PV is installed at the end of the doublewalled pipe. If a vacuum leak detector is used, a monitoring lead runs back to the device. Single-line system The double-walled line no. 4 is also monitored. A test valve PV is similarly installed at its end. PV tank Line 2 Line 3 Line 1 distributor block building DLR-G 1-7 Line 4 3 diagram of routing plan
4 Overview of leak detectors VLR... VLX 330/A-Ex Detector unit DLR-P... DLR-G... Type of leak detector VLR 410/E VLX 330/A-Ex DLR-G... DLR-P... Type of pipe FLEXWELL Safety Pipe BRUGG-STAMANT Safety Pipe SECON -X Petrol Station Pipe Area for installation Dry and frost-free area Flashpoint of transport medium < 55 C > 55 C Max. pipe length see Workshee LDS LDS LDS LDS Max. operating pressure 25 bar 10 bar 22 bar 1 bar Potential-free relay Remote monitoring option LOD Dimensions of housing (BxHxT) in mm 217x266x x200x x266x x266x110 dimensions detector unit 200x120x90 Additional criteria for selection Compact, uncomplicated Leak detector for Electronic leak detector Reliable leak detector leak detector flammable media with forall pressure stages for petrol stations low for consumer heating minimum maintenance operating pressu oil plants 4
5 Leak monitoring Online Diagnosis LOD According to VAUwS the operator of a plant with water-hazardous substances is obliged to provide evidence that the plant is leak-proof and to check the functioning of the safety precautions (leak detector) regularly. In order to optimise these function checks, BRUGG Rohrsysteme GmbH offers a remote monitoring system, LOD. What is LOD? Leak monitoring Online Diagnosis, LOD, is a system which for the first time realizes the safe and continuous remote monitoring of a leak detector. Each and every operating parameter is recorded around the clock (24/7), communicated automatically once every 24 hours by mobile telephony to the LOD server where it is analysed. That means that the correct operational functioning of the leak detector is checked every single day. How does LOD work? Any alarm is immediately communicated to the system when it occurs and leads directly and automatically to an or text message being sent to the addresses you have supplied. All alarm messages received are registered by the LOD system, repeated at regular intervals and only deleted after the cause of the alarm has been rectified on site. In this, LOD not only checks all functions of the leak detector but transmits the current pressure in the monitoring system as well as the leak status of the entire plant. This provides a hitherto unattained degree of certainty that the alarm signal will be relayed onwards and the necessary reaction ensured. Technical details and installation of LOD The leak detector comes equipped ex works with a pre-installed data transfer module (DTM) and a powerful externally visible rod aerial. The individual DTM is connected to the electronic system of the leak detector and logged in to the LOD via a serial number which identifies it clearly. For installations in areas which have a poor telephony signal, an aerial extension including an angled support is available. Overview of the data transmitted - daily report checking on the operation and functioning of the leak detector - real-time status of pressure in the system; alarm signal if pressure drops - leak tightness of the entire system consisting of the leak detector and the connected surveillance space - frequency of pump runs and overall running time of pump for ordering service checks - responsiveness check of internal sensor (probe or ZD) - status of an additional digital sensor (if connected to DTM) - output value of an additional analogue 4 20 mbar sensor (if connected to DTM), e.g. readout of residual pressure in gas bottles Advantages of the system - it is no longer possible to overlook alarm signals or ignore incoming alarms, alarm equipment can no longer be manipulated - can also be used for installations in remote locations which are not easily accessible and are only seldom visited, for petrol stations without attendants, standby power supply systems - safe from manipulation - maximum possible operating safety - maintenance checks can be optimally planned through automatic messages to identi fy service needs - minimal plant downtime ensured Availability of LOD LOD is available in all three DACH countries (Germany, Austria, Switzerland/red coloured). Availability over the rest of Europe (orange coloured) is under preparation. 5
6 Use case A helicopter fuelling station in New York City safe thanks to explosion-protected vacuum leak monitoring The Wall Street Heliport, located in lower Manhattan, is used for both tourist excursion flights and business air traffic. On any typical sunny summer day at the height of the tourist season, this heliport will experience more takeoffs and landings than JFK International Airport over the same period of time. In July 2010, during this peak operating season, a new fueling system was installed by BRUGG Pipesystems using BRUGG FLEXWELL -HL pipe. The first step was to lay out and connect a 500 ft. length of pipe along the length of the pier, to the first fuel station. The whole length of pipe was then carefully secured to the side of the pier, using a boat and mobile crane located onsite. This was a very complex and difficult process to complete, due to the changing tides, wave action caused by the movement of boat traffic on the East River and the constant helicopter rotors. At this point the piping was placed beneath the deck of the pier, and positioned in a channel between a support beam and the deck, and finally raised through a hole into the pump station all the while being subjected to the constant waves on the river. Lastly, an additional length of piping was installed between the tank and the pump station for filling and transferring jet fuel. The final pressure test confirmed that the BRUGG FLEXWELL -HL piping installation and the vacuum leak detector had no errors or leaks anywhere in the system. The customer will be able to rely on the quality, reliability and durability of this pipe installation for many years to come. 6 Left: The Wall Street Heliport in Manhattan/New York Centre: Installation work with no interruption in flight services Right: the explosion-protected vacuum leak detector next to the pumping station Tony Ramos, Core Engineered Solutions Again and again BRUGG We at Core sell compliance, value and long service life. The BRUGG pipe offers all of these values and stands alone in above ground applications. It also exceeds all the criteria for pipe below ground and under piers. I don t know any other double-wall pipe that protects against fires, UV and offers the same durability and flexibility. Core looks forward to many more opportunities with this product.
7 Use case Safe monitoring of the piping in a fuel depot The rebuilding of the Horny Hricov Terminal has been under discussion since 1997, when the first studies on re-routing the piping from the upper to the lower plant of SLOVNAFT were carried out. The lower SLOVNAFT plant in the Horny Hricov Terminal served as a distribution centre for petrol stations in Central and Eastern Slovakia, while the upper plant was used as the state material reserve. Following a number of changes in the SLOVNAFT refinery, the Horny Hricov Terminal was re-evaluated as the storage facility of the state material reserves of the Slovak Republic. The necessity to re-route the piping between the two plants resulted from the extension of the motorway from Bratislava in the West to Kosice in the East. This motorway ran over the piping connecting the two plants. In order not to hinder operations it was necessary to re-route the piping so that the motorway routing would not have to be taken into consideration in the event of reconstruction work being needed. The project consists of 13 lines of BRUGG-STAMANT double-walled safety piping laid below the surface. BRUGG Rohrsysteme GmbH supplied 4,446 m of double-walled piping and 1,611 m of single-walled piping, with dimensions ranging from DN 80 to DN 300. Transport media are petrol, crude oil and gas. DLR-G 8 S positive pressure leak detectors are used. Left: Installing the outer pipe casing BRUGG-STAMANT Safety Pipe Centre: Routing crossing the motorway below Right: positive pressure leak detectors in protective housings Miroslav Tomsik CHEMPROCES GmbH Further 811 m of BRUGG-STAMANT safety piping delivered We got the contract for the SLOVNAFT project because of already existing know-how and it was an important reference in the Slovak Republic. Thanks to this reference our companies delivered a further 811 m of BRUGG- STAMANT safety piping in 2010 for the project Port on the Danube in Bratislava. With the need for retrofitting equipment, two more projects are expected on top of this within the next three years. Presently the piping has been in service trouble-free for over five years. 7
8 Pipe systems for the future District heating Industry Petrol stations System packages 12 / 12 / ex. / / pictures by Key Your partner for pipe systems We are the people you should talk to when you need to find efficient solutions for transporting liquid materials. With our project engineers, development department, in-house production unit, and our professional team of fitters, we have the know-how and the resources to look after your projects competently and reliably in the sectors of heating systems, petrol station construction, industrial plant construction, and system packages. Customer-specific solutions Brugg is the full service provider in the field of single-wall, double-wall and insulated pipe systems. This know-how allows us to manufacture project-specific customised items. Give us a call! Our engineers would be pleased to advise you and find a made-to-measure solution. Brugg Rohrsystem AG Industriestrasse 39 CH-5314 Kleindöttingen phone +41 (0) fax +41 (0) [email protected] International network Our global partnership network can be reached on site at any time. More than 34 partners in 20 different countries will look after you wherever you are. BRUGG Rohrsysteme GmbH Adolf-Oesterheld-Straße 31 D Wunstorf phone +49 (0) fax +49 (0) [email protected] A company of the BRUGG Group
FLEXWELL Safety Pipe. Pipe systems for installations Technical details
Pipe systems for installations Technical details Notes 08.04.2013 T page 2 Contents 4.0 4.0 Contents 4.1 System description 4.100 System description FLEXWELL Safety Pipe 4.105 System description FLEXWELL
Extract of the White paper Reduce energy costs in compressed air systems by up to 60%
Extract of the White paper Reduce energy costs in compressed air systems by up to 60% How can potential energy savings be identified? There are various measures for realising potential savings in compressed
PROCESS AUTOMATION. ALARM SYSTEMS FOR SEPARATORs PRODUCT OVERVIEW
PROCESS AUTOMATION Protection for the environment ALARM SYSTEMS FOR SEPARATORs PRODUCT OVERVIEW warning devices for separator systems Detects dangers to protect the environment Water is the basis of all
DUST EMISSION MONITORING SYSTEM
Applications Measurement of dust concentration in dry or moist, steamsaturated and corrosive stack gases Monitoring of municipal and hazardous waste and sewage sludge incinerators Monitoring of power plants
Concremote calibration box
999808502-02/2014 en-gb The Formwork Experts. Concremote calibration box User Information Instructions for assembly and use (Method statement) Introduction User Information Concremote calibration box Introduction
Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations
VI Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations 5 Guidelines for Design, Equipment and Testing of Gas Welding Installations on Seagoing Ships Edition
Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230
Technologies Gas extinguishing systems MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230 ire protection Efficient and compact MX 1230 fire extinguishing systems fight fires using Novec
QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems
The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system
BOGE AIR. THE AIR TO WORK. CONTROLS
BOGE AIR. THE AIR TO WORK. CONTROLS Over 100.000 compressed air users expect more when it comes to their compressed air supply. BOGE air provides them with the air to work. It is estimated that energy
AMTRON E-30 Compact heat and cooling meter
AMTRON E-30 Compact heat and cooling meter Application The compact AMTRON E-30 meter is used for energy consumption measurements for heating and cooling applications in small premises such as apartments,
Instruction Manual Differential Pressure Transmitter
DE28 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance
Druck PV 62x pneumatic/hydraulic pressure stations
GE Sensing & Inspection Technologies Druck PV 6x pneumatic/hydraulic pressure stations safety and quick reference guide - K08 A. PV 6: Pneumatic pressure station (Figure A.) -90 mbar to 0 bar (-3. to 300
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
The Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 [email protected] www.leoni-infrastructure-datacom.com
Elektromotoren und Gerätebau Barleben GmbH
Elektromotoren und Gerätebau Barleben GmbH OPERATING INSTRUCTIONS Transformer Protection Relay NM Series (Buchholz principle) Elektromotoren und Gerätebau Barleben GmbH Table of contents Page 1. Safety
SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE
Series Circuit Breaker Monitors CONSOLIDATED Electronics, Inc. MONITORING THE FUTURE Why SF Gas Density Monitors? 6 Cut Maintenance Costs Your capital investment may be recovered with the elimination of
SHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
TYXIA. *2702178_Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF 642-1 channel
Installation and User Guide TYXIA Wireless receiver TYXIA RF 642-1 channel DELTA DORE Bonnemain - 35270 COMBOURG - France E-mail : [email protected] Unit compliant with the requirements of directives:
Strong partners offer perfect solutions. Automatic filtration and maintenance of engine lubricating oil in diesel locomotives
Strong partners offer perfect solutions Automatic filtration and maintenance of engine lubricating oil in diesel locomotives The task Reliable maintenance of lubricating oil quality Lubricating oil is
27 July 2009 I 54-1.65.25-63/08. Klenk GmbH Eichelstraße 15, D-88285 Bodnegg-Rotheidlen
General Technical Approval German Institute for Construction Engineering PUBLIC-LAW INSTITUTION Approval body for construction products and types of construction German Construction Industry Inspection
www.optimumheat.co.uk
The modern wood pellet boiler with built-in flexibility and remote fingertip control Up to 98% efficient Wide output range Simple touch-panel control Remote control & maintenance Extremly low emissions
Vacuum Gate Valve DN 100 and DN 150
Vacuum Gate Valve DN 100 and DN 150 WER Dok.E.02.050_02.051 1. Introduction/Safety Instructions 2. Description 3. Technical Data 4. Installation 5. Operation 6. Maintenance Instructions 7. Spare Parts
Why a torque measuring system?
T-Sense P R O D U C T B U L L E T I N 660 Optical Torque Measuring Systems Introduction The use of a T-Sense torque measuring system means efficiency improvement, overload protection and prevention of
LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring
LNG Monitoring Fiber-Optic Leakage Detection System Pipeline leakage detection Regasification and liquefaction monitoring Tank annulus and base slab monitoring Spill containment control Intelligent Solutions
Ultrasonic Gas Leak Detection
Ultrasonic Gas Leak Detection What is it and How Does it Work? Because every life has a purpose... Ultrasonic Gas Leak Detection Introduction Ultrasonic gas leak detection (UGLD) is a comparatively recent
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
Power consumption (kw)
OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components
Please refer to the chapters below for detailed information about all aspects of the products usage.
EUR_STELLAZ Wall Radiator Thermostat Valve Control Firmware Version : 0.4 Quick Start S This device is a wireless sensor. All operation is performed using the little button behind the round hole in the
emobility WAGO Leading the Charge
emobility WAGO Leading the Charge Six Steps to a Full Battery WAGO supports every aspect of charging from: TO-PASS GPRS Modem, VPN Router, 761-520 Identification / Registration /Authorization RFID SMS
Intelligent Terminal Automation System
Intelligent Terminal Automation System. Rockwell Automation intelligent Terminal Automation Systems provide a complete automation solution for tank terminals beyond your expectations The Rockwell Automation
Gas Detection for Refining. HA University
Gas Detection for Refining HA University Refinery Process and Detection Needs Refining i Crude Oil Final Products Coke Asphalt Waxes, Lubricating Oils and Greases Kerosene, Jet Fuel, Diesel Fuel, Home
Product Information Fire alarm panel 8000 C
Product Information Fire alarm panel 8000 C Fire alarm panel 8000 C, basic configuration In common with all modern Esser panels, the 8000 C fire alarm panel is based on high-performance ringbus technology.
Pressure regulating valve with modulating kit, type DRV
Operation Installation and Maintenance Instructions Pressure regulating valve with modulating kit, type DRV hp-technik GmbH Industriepumpen-Förderaggregate und Anlagenbau Gablonzer Straße 21 D-76185 Karlsruhe
SAVEL MOBILE STATIONS
SAVEL MOBILE STATIONS www.savelglobal.com Fuel Automation LPG CNG SAVEL height height height height Gas-Station Container and Storage Tank Container Description The SAVEL is a containerised storage tank
Class I Leak Detection Systems - Highest level of monitoring and prevention of double walled tanks and pipes, according EU Standard EN 13160-2
Class I Leak Detection Systems - Highest level of monitoring and prevention of double walled tanks and pipes, according EU Standard EN 13160-2 Advantages Working Principle Product Overview www.thomas-leak-detection.com
Power Generation Power Plants. Electrical Engineering Systems for Power Plants
Power Generation Power Plants Electrical Engineering Systems for Power Plants Profile Persuasive solutions: SAG a service provider in demand The electrical engineering infrastructure in modern industrial
VDL 53 - Vacuum drying oven for flammable solvents
Vacuum drying ovens VDL 53 - Vacuum drying oven for flammable solvents The VDL series ensures maximum safety when drying organic solvents in accordance with TÜV/GS guidelines. The interior chamber is designed
T a b l e o f C o n t e n t s
w w w. g e n t e c h e a l t h c a r e. c o m M E D I C A L M O N I T O R I N G, A L A R M A N D C O N T R O L S Y S T E M S I n t e r n a t i o n a l E d i t i o n Technology for a Better Future Company
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business
Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com.
Instruction Manual Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without
IFC 070 Technical Datasheet
IFC 070 Technical Datasheet Electromagnetic signal converter Battery driven with low energy consumption Quick and easy to install and operate External data logger and GSM module for remote data transfer
VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)
VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
Standard the the Raising
Raising the Standard Introduction to BS 5839-1:2013 An Overview of the BS 5839 1:2013 for professionals who are responsible for the provision of fire detection and alarm systems for buildings Agenda Introduction
Woods Hole Group, Inc. Oceanography and Measurement Systems Division INTEGRATED REAL-TIME MONITORING SYSTEM
Woods Hole Group, Inc. INTEGRATED REAL-TIME MONITORING SYSTEM Woods Hole Group, Inc. (WHG) has developed the Integrated Real-time Monitoring System (IRMS) as a general-purpose data acquisition and telemetry
Service Manual Trucks
Service Manual Trucks Group 36 Vehicle Electronic Control Unit (MID 144), Diagnostic Trouble Code (DTC), Guide From build date 1.2007 PV776-88951780 Foreword The descriptions and service procedures contained
HEAVY-DUTY HAND CUTTING TORCHES AND ACCESSORIES. Page 1 Version no.: V0-090902
Page 1 HEAVY-DUTY HAND CUTTING TORCHES AND ACCESSORIES Page 2 Heavy-Duty Hand Cutting Torch HCT 663: With lever-operated valve for cutting oxygen, for cutting duties involving high thermal loads on slabs,
Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau
KA 180F/00/en/06.01 (a) 52010984 Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau Safety instructions The FTS 20 floating switch may only be used as a level limit switch
APPLICATION FOR ADR ROAD VEHICLE APPROVAL CERTIFICATE
APPLICATION FOR ADR ROAD VEHICLE APPROVAL CERTIFICATE Before filling in this application, please see notes on Page 8. Consult your DGSA if unclear about any aspect. (All relevant parts of this application
Integrated pressure measurement
Integrated pressure measurement The new sensors RPT 010 and IKT 010/IKT 011. Compact dimensions. Direct installation, no additional power supply. No special cable needed. Integrated pressure measurement
VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A
Technical Data Manual Model Nos. and pricing: see Price List Vacuum tube collector based on the heat pipe principle For the utilisation of solar energy VITOSOL r 200-T SP2A Product may not be exactly as
On-line Dissolved Gas Analysis
On-line Dissolved Gas Analysis accord. to IEC 567/ASTM 3612 Online-Monitoring of transformers Automatic on-line analysis of 11 gases The analysis is done in 2 steps with high selectivity and accuracy fully
PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual
PART 8: FIELD WIRING A. INSTALLATION MUST COMPLY WITH: 1. National Electrical Code and any other national, state, provincial or local codes or regulations. 2. In Canada, CSA C22.1 Canadian Electrical Code
Backflush filter R8-30W
Backflush filter R8-30W With internal pressure segment cleaning, rated pressure to 40 bar (580 psi) Connection sizes: DN 200 to DN 500, welded design 1. Features Powerful, fully automatic filtration _
Digital Single Axis Controller
Digital Single Axis Controller The concept of intelligent hydraulic drive a vision? DSAC (Digital Single Axis Controller) Do you need hydraulic servo drive for your machine/system? What would it be like
Utilizing Furukawa Optical Fiber Technology. Optical Fiber Sensing System
Utilizing Furukawa Optical Fiber Technology Optical Fiber Sensing Point Special features of optical fiber sensing s 1Reduced installation cost Sensors (measurement location) require no electrical work
Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank
Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank This specification describes requirements for a Diesel Fuel Day Tank System consisting of one or more fuel tanks, an Electronic
Fire Pump Plan Review March 2010
Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:
Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success
Labkotec SET Labkotec separator alarm system protecting our environment Designed to comply EN 858-1&2 and PPG3 norms Warns of excessive levels of oil, sludge & liquids Prevents pollution incidents Fail-safe
Diagram of components 2. Reducer..3
Index Diagram of components 2 Reducer..3 Rail Filter - Rail Filter 4 - MAP Sensor.4 Injector & Nozzle - Single Injector / Rail Injector...5 - Bi-Fuel Connector...6 - Nozzle...7 ECU...8 Switch 9 Wiring
UST RULES CHANGES. Heather Peters, Environmental Specialist
UST RULES CHANGES Heather Peters, Environmental Specialist Today s Topic 2011 Rule package- what s left? Upcoming rule changes Federal Regulation Changes & Testing Protocols How are you doing? 2011 Rule
Hydraulic Control Solutions
Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district
Integrated Custom Systems
Integrated Custom Systems Compact panels Standard Manifolds & Assemblies Electronic pressure control Custom manifolds & Assemblies Automated test benches S t r e a m l i n e y o u r p r o c e s s Complete
PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator
3.635.5275.251 IM-P486-19 CH Issue 2 PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator Installation, Start-up and Operation Manual 1. Safety information 2. General product information 3.
Elektromotoren und Gerätebau Barleben GmbH
Elektromotoren und Gerätebau Barleben GmbH OPERATING INSTRUCTIONS Transformer Protection Relay (Buchholz principle) Elektromotoren und Gerätebau Barleben GmbH Table of contents Page 1 Safety instructions
USER MANUAL OPERATION AND USE OF CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM
USER MANUAL OPERATION AND USE OF CAR WITH Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM Page 2 z 7 Table of contents 1. STARTING THE ENGINE... 3 2. CONTROL PANEL... 3 2.1 Indication of the current level
Revised April (May) 2015
Section 19.0 Cross Connection Control Policy 19.1 Responsibility 19.1.1 The Elkhart Water Utility has the responsibility to supply safe, potable water from the source to the point of delivery defined as
Proactive Monitoring of Friction Management Systems Reduces Costs and Downtime
Proactive Monitoring of Friction Management Systems Reduces Costs and Downtime By: Nicholas Dryer and David Mintskovsky Abstract The latest research shows that friction management systems reduce friction
Maxi Pressurisation Units (Maxi, Maxi Plus & HP)
Maxi Pressurisation Units (Maxi, Maxi Plus & HP) Installation and Maintenance Instructions Contents 1 Dimensions 3 1.1 Installation 4 1.1 Mains/boosted cold water inlet 4 1.2 Connection to the system 5
BEST PRACTICES IN LEAK DETECTION AND REPAIR (LDAR) PROGRAMS. November 06, 2014 By: François Thibodeau, Eng.
BEST PRACTICES IN LEAK DETECTION AND REPAIR (LDAR) PROGRAMS November 06, 2014 By: François Thibodeau, Eng. 2 PRESENTATION OVERVIEW 1. Essential Components of a LDAR Program 2. LDAR Best Practices a. A
FLUXUS Energy. Manage energy effectively using non-invasive measuring technology. Heat usage, chilled flows and compressed air flow rate
Manage energy effectively using non-invasive measuring technology FLUXUS Energy Heat usage, chilled flows and compressed air flow rate Heating and air-conditioning technology Non-invasive power of thermal
Important Ontario Fire Code Information for Building Owners in the City of Windsor
Important Ontario Fire Code Information for Building Owners in the City of Windsor This information is intended to be used a reference only. For a complete listing consult the Ontario Fire Code or contact
Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO
GSM-PRO GSM-PRO perfect for communication CONTA-CLIP s GSM-PRO module offers a remote control and maintenance solution which allows you to monitor and control decentralized facilities. The GSM-PRO module
Intelligent System Solutions for Fleet Fuelling Stations.
Intelligent System Solutions for Fleet Fuelling Stations. As a tradition competent and innovative. Success always has a story: since 1928 the foundation for this success was laid by the inventor Dr. Herbert
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases
Product information EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Proven Analyzer Technology Measuring total hydrocarbons
CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions
Mounting and operating instructions CONTOIL DFM 8EDM Table of contents Safety instructions 2 - Designed use - Installation, commissioning and operation - Operational safety - Return of the instruments
CHAPTER 8 CIVIL DESIGN
CHAPTER 8 CIVIL DESIGN A. GENERAL This Chapter includes standards and design considerations for other civil engineering design in structural, drainage and utilities. Design considerations for electrical
Hydrogen Leak Detection. 9012 XRS system. The complete system for leak detection using hydrogen gas
Hydrogen Leak Detection 9012 XRS system The complete system for leak detection using hydrogen gas Yes, it leaks but where? Telephone cables Gas-filled Petrol stations Gas pipelines power cables Heating
ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS
ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS SECTION 1 GENERAL SPECIFICATIONS I. SCOPE This specification outlines the requirements for a pre-engineered
Ultrasound Condition Monitoring
Ultrasound Condition Monitoring Whitepaper Alan Bandes UE Systems, Inc. Abstract: Instruments based on airborne/structure borne ultrasound technology offer many opportunities for reducing energy waste
CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
Measurement Solutions for Refrigeration Technology.
Measurement Solutions for Refrigeration Technology. Digital manifold, leak detection, vacuum measurement, and lots more. Testo refrigeration technology Digital is better: Refrigeration technology expertise
Spill Control Prevention Plan (SCPP)
Spill Control Prevention Plan (SCPP) FACILITY INFORMATION PLEASE PRINT Facility Name: Mailing Address: Physical address if different: Owner Name: Owner Address: Primary Contact Name: Work Phone Number:
BETAtrans. Cables and Systems for Rolling Stock. Edition 2006
BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For
HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT
HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT MAXIMATOR GmbH 2 MAXIMATOR has an extensive know-how concerning concept, development, construction and manufacturing of test benches and
Self-operated Temperature Regulators Temperature Regulator Type 1u
Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points ) from 0 to 250 C G ½ to G or DN 5 to 50
OZW30. Central Unit SYNERGYR
2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control
südmo systems for the dairy & food industries
südmo systems for the dairy & food industries fluid process SOLUTIONS systems for the dairy & food industries convincing Solutions! Engineering, Project management, Automation, Valve technology & Assembly
Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23
Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 Application Pressure regulators for set points from 5 mbar to 28 bar Valves in nominal sizes DN 15 to 100 Nominal pressures
2000 Series Ultrasonic Welding
2000 Series Ultrasonic Welding Modular Standard Components Exclusively from BRANSON worldwide Second Generation Digital Power Supplies Branson Worldwide Best for Plastics BRANSON offers a wide range of
MAKE OF AUTOMOBILE: NUMBER : 076/0800901 DATE : 2008-12-08 Copyright Prins Autogassystemen B.V. 2008 VERSION NR : 2008-10-24 B
MAKE OF AUTOMOBILE: HONDA TYPE: CIVIC PISTON DISPLACEMENT: 1800 NUMBER OF VALVES: 16 ENGINE NUMBER: R18A TYPE VSI INJECTOR ( COLOR ) ORANGE MODEL YEAR: 2008 ENGINE SET NUMBER 348/0250200.07 NUMBER : 076/0800901
2.24. Pump Controller 704. Data Sheet
Pump Controller 704 2.24 There are several reasons to choose an MJK pump controller. Pump controller 704, as described in this data sheet, was introduced in 1989. It has been updated several times with
A Practical Guide to Free Energy Devices
A Practical Guide to Free Energy Devices Part PatE17: Last updated: 24th November 2006 Author: Patrick J. Kelly This is a patent application from Stephen Meyer, brother of the late Stan Meyer. While this
siemens.com/mobility Radar detectors of the Heimdall family High detection rate, easy installation
siemens.com/mobility Radar detectors of the Heimdall family High detection rate, easy installation Heimdall radar detectors from Siemens: A family that provides valuable benefits, Heimdall is the watchman
Evaporative emissions system
just a test. Evaporative emissions system 20-48 Function description of EVAP canister system Depending upon the air pressure and ambient temperature, fuel vapor will form above the level of fuel in the
Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems
Page 1 of 5 Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems New Hampshire Department of Environmental Services
Hydraulic control unit series 0086-372-01
Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3