Windy Boy 5000 Windy Boy 6000 Inverter for Wind Energy Power Plants
|
|
|
- Harvey Flowers
- 9 years ago
- Views:
Transcription
1 Windy Boy 5000 Windy Boy 6000 Inverter for Wind Energy Power Plants Operating Instructions Version 1.0 WB50_60-11:FE4105 TBE-WB50-60
2
3 SMA Technologie AG Revision Histroy Revision History Document number Changes Author WB50_60-11:FE4105 First issue Welzel Operating Instructions WB50_60-11:FE4105 Page 3
4 SMA Technologie AG Page 4 WB50_60-11:FE4105 Operating Instructions
5 SMA Technologie AG Explanation of Symbols used in this Document Explanation of Symbols used in this Document This symbol indicates information that is essential for a trouble-free and safe operation of the product. Please read these sections carefully in order to avoid any damages of the equipment and for optimal personal protection. This symbol indicates information that is required for the optimal operation of the product. Read these sections carefully in order to ensure an optimal operation of the product and all its features. This symbol indicates an example. Operating Instructions WB50_60-11:FE4105 Page 5
6 Legal Restrictions SMA Technologie AG Liability exclusion The information contained in this documentation are the property of SMA Technologie AG. No part of this documentation may be published without written permission from SMA Technologie AG. A reproduction for internal purposes for the evaluation of the product or an appropriate application is permitted and does not require authorization. All information are based on our "General Terms and Conditions of Delivery of SMA Technologie AG. The content of this documentation is reviewed continuously and adjusted, if necessary. SMA Technologie AG provides this documentation without exclusion of deviations and without warranty of completeness. You will find the current version on the Internet at or can obtain it via the usual sales channels. Warranty or liability claims for all kinds are excluded in case of damages due to: Inappropriate use of the product Operation of the product in an improper environment Operation of the product without considering the relevant safety regulations Non-fulfillment of the warnings or safety instructions described in the documentation for the product Operation of the product under faulty conditions concerning security and protection Arbitrary changing of the product or the provided software Failure of the product due to interference of connected or contiguous devices out of legal limit values Disasters and force majeure Software Licensing The use of the provided software by SMA Technologie AG is subject to the following conditions: The software may be reproduced for internal purposes and installed on any number of computers. Provided source codes can be changed and adjusted on the company s own authority according to the internal purpose. Driver may be ported to other operating systems as well. No part of the source codes may be published without written permission of SMA Technologie AG. Sublicensing of the software is not acceptable. Liability limitation: SMA Technologie AG disclaims liability for any direct or indirect consequential damages arising from the use of the software produced by SMA Technologie AG. The same applies for the provision and/or non-provision of support. Provided software not produced by SMA Technologie AG is subject to the respective licensing and liability agreements of the manufacturer. Trademarks All brand and product names used herein are trademarks or registered trademarks of their respective holders, although they may not be specifically designated as such. SMA Technologie AG Hannoversche Strasse Niestetal Germany Tel. (+49) Fax (+49) [email protected] 2005 SMA Technologie AG. All rights reserved. Page 6 WB50_60-11:FE4105 Operating Instructions
7 SMA Technologie AG Table of Contents Table of Contents 1 Introduction Safety information Unit description Appropriate usage of the Windy Boy 5000 / Device construction Operating modes Normal operation Critical, faulty operation Non-critical, faulty operation Description of the operational status Messages in the optional display Setting the display language Maintenance and care Turbine operation Overview Characteristic curve function Characteristic curve operation in "Turbine" operating mode General setting example Maintenance and care Expansions Sunny Data Sunny Data via Powerline Sunny Data over RS Sunny Data over RS Sunny Beam Sunny Data Control over Sunny Beam Sunny Boy Control Light Sunny Boy Control Sunny Boy Control Plus Sunny Data Control Sunny WebBox Sunny Portal Sunny TV Technical data Windy Boy DC connection data Grid connection data General data Windy Boy Operating Instructions WB50_60-11:FE4105 Page 7
8 Table of Contents SMA Technologie AG DC connection data Grid connection data General data General information Measurement channels and messages Status messages Windy Boy 5000 / 6000 Operating parameters Fault messages Declaration of conformity (CE) Import certificate Stand-alone systems Contact Page 8 WB50_60-11:FE4105 Operating Instructions
9 Introduction 1 Introduction The installation of the Windy Boy 5000 / 6000 may only be done by qualified technicians. The installer must be approved by the utility company. Please read the installation guide carefully before you begin with the installation. The installation of utility interactive power sources must be compliant with all applicable regulations of the utility company and with all applicable regulations and standards. The Windy Boy inverters make it possible to operate small wind turbines as gridconnected systems. Grid-connected means that the energy generated by the wind turbine can be fed directly into an existing house power grid, a stand-alone power system, or the mains supply. To this end, the Windy Boy converts the direct current (DC) from permanent-magnet wind turbines, which vary with speed, into grid-compatible alternating current (AC). The Windy Boy requires the constant presence of mains supply voltage! The Windy Boy 5000 / 6000 complies with all the VDEW (Verband der Elektrizitätswirtschaft German Electricity Industry Association) regulations for the connection and parallel operation of electrical power units to the low-voltage grid of the electricity supply company. This also encompasses the regulations of the German Professional Association for Precision Engineering and Electro technology relating to "Automatic switching of electrical power units" (SMA grid guard) and/or DIN VDE In addition to this, the Windy Boy 5000 / 6000 conforms to the electromagnetic tolerance regulations and the low-voltage regulations of the relevant combined European norms, as confirmed in the CE conformity declaration (10.3 "Declaration of conformity (CE) (page 63)). The documentation provided here covers all such topics that are of interest when operating Windy Boy 5000 / 6000 inverters. In addition to explanations of the operational methods of the device and detailed technical data, advice as to data capture and analysis is also provided. Information relating to the installation and commission of the Windy Boy 5000 / 6000 should be taken from the installation instructions delivered with the device. The Windy Boy 5000 / 6000 inverter has a special operational mode for wind turbines which allows performance adjustment to the characteristic curve of the generator. In this way you will obtain maximum yields from your wind turbine. A wide input voltage range, high efficiency and a freely configurable output characteristic curve with the highest level of reliability are only some of the properties that are useful for your grid-connected system, or in a stand-alone system when combined with the Sunny Island. Operating instructions WB50_60-11:FE4105 Page 9
10 Introduction The Windy Boy 5000 / 6000 is compatible with all SMA communications products (RS232, RS485, Powerline, Wireless, Display), providing numerous possibilities for diagnosis, data visualization and remote maintenance of your small wind turbine system. For stand-alone systems, that use the Sunny Island: Please configure your Windy Boy 5000 / 6000 according to the specifications in the Sunny Island manual. Configuration of the V/I properties of the Windy Boy 5000 / 6000 with respect to your wind turbine: the parameters U PV Start, U DC WindStart and U DC WindMax must be configured to guarantee optimum operation of your Windy Boy 5000 / 6000 with your wind turbine. The configuration process is described in chapter 6 "Turbine operation (page 33). Apart from the parameter settings, the Windy Boy 5000 / 6000 is identical to the Sunny Mini Central photovoltaic inverter and can therefore also be used as a PV inverter. Please download the Sunny Mini Central manual from and if you are planning to use the Windy Boy 5000 / 6000 in a photovoltaic system please contact us on the SMA hotline. Page 10 WB50_60-11:FE4105 Operating instructions
11 Safety information 2 Safety information Opening of the device, and any Windy Boy Netzwechselrichter für Windenergieanlagen Grid tied inverter for wind turbines electrical installation, repair or modification of the Windy Boy 5000 / 6000 may only be performed by qualified electrical personnel. Even when no external voltage is present, the device can still contain high voltages and the danger of electrical shock. The temperature of individual parts of the case of the Windy Boy 5000 / in particular the temperature of the heatsink - can reach 60 C in normal operation. Touching could result in burns! The Windy Boy 5000 / 6000 contains an independent mains disconnection device, the "SMA grid guard". It ensures that the Windy Boy 5000 / 6000 complies with the VDEW (Verband der Elektrizitätswirtschaft German Electricity Industry Association) regulations for the connection and parallel operation of electrical power units to the low-voltage grid of the electricity supply company and with DIN VDE 0126 (4.99), which forms a part of these regulations. Operating instructions WB50_60-11:FE4105 Page 11
12 Safety information Page 12 WB50_60-11:FE4105 Operating instructions
13 Netzwechselrichter für Windenergieanlagen Grid tied inverter for wind turbines Unit description 3 Unit description 3.1 Appropriate usage of the Windy Boy 5000 / 6000 The Windy Boy 5000 / 6000 is designed for the conversion of DC voltage from a wind turbine (permanent magnet generator) into AC voltage for feeding into the public mains supply. The technical data are described in more detail in chapter 9 "Technical data (page 49). Overvoltage Protection Netzwechselrichter für Windenergieanlagen Grid tied inverter for wind turbines Windy Boy Control unit Control unit Wind Generator Converter Rectifier Windy Boy Public Mains Grid Many wind turbine manufacturers offer an extra over-voltage protection module. These components prevent the destruction of the downstream Windy Boy in the case of overvoltage. Overvoltage can occur under the following conditions: High turbine rotation speeds under strong wind conditions An increase in turbine rotation speed caused by load-shedding when the Windy Boy is disconnected from the mains supply e.g. in the case of mains interference or power outage. The overvoltage protection system has the following tasks: When a pre-defined voltage is reached, the Windy Boy is disconnected from the generator and a short-circuit slows the generator and/or brings it to a standstill. Some devices reduce the turbine rotation speed, and thus the generator output voltage, by switching in a resistor assembly (Dumpload). The electrical energy generated by the turbine is then converted to heat. Operating instructions WB50_60-11:FE4105 Page 13
14 Unit description In grid-connected systems, we recommend the use of one of the electronic protection mechanisms described here. Please note that overvoltage on the Windy Boy can lead to destruction of the device. In addition to this, you lose the right to all warranty claims - even if the maximum input voltage of the Windy Boy is only exceeded for a short time. The electronic protection systems described here are preferable to mechanical solutions (pitch control, "turning out of the wind") in every case. Any other use of the Windy Boy 5000 / 6000 leads to loss of the right to all warranty claims. In case of overvoltage, immediately disconnect the DC input of the Windy Boy 5000 / 6000! The presence of excessive input voltage can lead to irreparable damage! When the Windy Boy 5000 / 6000 receives an excessive DC input voltage, it automatically disconnects from the mains supply and no longer feeds power into the grid. When the Windy Boy 5000 / 6000 is in operation, you must always first disconnect the AC voltage (mains supply) and only then should you disconnect the DC voltage from the Windy Boy 5000 / 6000! Page 14 WB50_60-11:FE4105 Operating instructions
15 Unit description 3.2 Device construction An attractive, functional design is one of the major design objectives of the entire Windy Boy 5000 / 6000 product range. In its basic configuration, the Windy Boy 5000 / 6000 has the proven status display consisting of three LEDs. An extra display can be provided already installed or can be retrofitted. As long as it is installed and commissioned according to the technical specifications, the Windy Boy 5000 / 6000 can be operated without any further modification or configuration. The device parameters can however be modified, if required. + Windy Boy 5000 / 6000 Enclosure IP54 (outside installation possible) DC - input with 4 x 2 DC connectors Characteristic wind curve Bridge Transformer SMA Grid Guard L N PE AC - output with terminals Overvoltage protection: Thermally monitored varistors Optional display (IP65) Optional communications interface: RS232 RS485 Powerline OptiCool R An extra communications interface is required for ideal adaptation of the Windy Boy 5000 / 6000 to suit the particular wind turbine being used, and this can also be used for reporting operation data. For further details, please refer to chapter 8 "Expansions (page 41). Operating instructions WB50_60-11:FE4105 Page 15
16 Unit description All DC connections and connections for the mains supply, as well as any optional communications connections are to be found on the underside of the Windy Boy 5000 / Each of the + and - DC connections are internally connected in parallel within the Windy Boy 5000 / Plug connector for DC+ Plug connector for DC- Cable opening for the mains supply connection Opening for optional communication via RS232, RS485 or radio (PG16) Page 16 WB50_60-11:FE4105 Operating instructions
17 Netzwechselrichter für Windenergieanlagen Grid tied inverter for wind turbines Unit description 3.3 Operating modes The operational status is displayed using three light-emitting diodes (LEDs) in the cover of the Windy Boy 5000 / To allow the device to signal its operational status via the integrated LEDs, the Windy Boy 5000 / 6000 must be connected to the DC side of the system. There must be enough wind energy present, so that the Windy Boy 5000 / 6000 has adequate DC voltage. Windy Boy Especially in the first year of operation, the operator of the system should check this display under different wind speeds. A complete description of the possible displays can be found in chapter "Description of the operational status (page 19). These can be split into three categories: Normal operation As long as the green control LED is on, or blinking, the Windy Boy 5000 / 6000 is operating normally. The simultaneous illumination of all three LEDs is also an indication of normal operation ("Initialization"). All other displays are a sign of abnormal operation. Operating instructions WB50_60-11:FE4105 Page 17
18 Unit description Critical, faulty operation A comprehensive safety concept limits the number of critical conditions that can occur to a single situation: Input voltage exceeds the permitted value This is indicated by the following blink-code on the yellow LED: The yellow LED illuminates 4 times LED on LED off s 3s 1s 1s 1s 1s The message is repeated 3 times and then begins again. The yellow fault LED illuminates for 5 seconds when the fault occurs, and then begins displaying the blink code of: 3 seconds off and then 4 times briefly on. This code is displayed three times in succession. If the fault is still present, the fault display starts again from the beginning. The presence of excessive input voltage can lead to irreparable damage! Immediately disconnect the DC input of the Windy Boy 5000 / When the Windy Boy 5000 / 6000 receives an excessive DC input voltage, it automatically disconnects from the mains supply and no longer feeds power into the grid. When the Windy Boy 5000 / 6000 is in operation, you must always first disconnect the AC voltage (mains supply) and only then should you disconnect the DC voltage from the Windy Boy 5000 / 6000! Non-critical, faulty operation All other fault codes indicate some form of faulty operation, which are not usually dangerous to people or equipment, but which should nevertheless be investigated and corrected. Despite all precautions, it is possible that other faults may occur that cannot be displayed (e.g. failure of the status display). In order to recognize such faults, the operator of the system should use the explanations in chapter "Description of the operational status (page 19) to check the plausibility of the displayed status. Further detailed diagnoses are possible using the communications options detailed in chapter 8 "Expansions (page 41). Page 18 WB50_60-11:FE4105 Operating instructions
19 Unit description Description of the operational status No (or low) input voltage All LEDs are off. The Windy Boy 5000 / 6000 is in Standby mode. This situation occurs when the input performance at the Windy Boy 5000 / 6000 is too low for feeding the mains supply (DC input voltage < approx. 80 V) and for satisfying the on-board power requirements. Initialization Working mode All LEDs are on. Green LED is on. The on-board computer of the Windy Boy 5000 / 6000 is presently in the initialization process. The DC input voltage of the Windy Boy 5000 / 6000 lies between approx. 80 V and approx. 120 V. The power is adequate for the onboard power requirements but insufficient for mains supply feed-in or for data transmission. The Windy Boy 5000 / 6000 has successfully passed the measurement electronics and SMA grid guard self-tests and has begun feed-in operation. The Windy Boy 5000 / 6000 is working normally and is feeding electricity into the mains supply. It is converting the DC voltage from the wind turbine according to the V/I characteristic curve defined by U PV Start, U DC WindStart and U DC WindMax (chapter 5 Turbine operation" on page 33). Operating instructions WB50_60-11:FE4105 Page 19
20 Unit description Stop 1s Green LED blinks 3 times per second. The Windy Boy 5000 / 6000 is in Stop mode. Among other functions, the measurement electronics are calibrated and then finally, the device switches to "Waiting" mode. The "Stop" mode can also be manually set by the system operator via the Sunny Boy Control or the Sunny Data PC program. In this case, the Windy Boy 5000 / 6000 remains in "Stop" mode until a new operating mode ("MPP mode", "Turbine mode") has been set. Maintenance, grid monitoring 1s The green LED blinks once per second. The Windy Boy 5000 / 6000 checks if the initial conditions necessary for feeding the mains supply are satisfied (e.g. start voltage) and then begins monitoring the mains supply. Derating 1s The green LED turns off briefly once per The temperature monitoring of the Windy Boy 5000 / 6000 has reduced the output performance to prevent the device from overheating. If this occurs often, then this is an indication of inadequate heat dissipation. To avoid unnecessary reductions in yield, in this case it should be checked if the Windy Boy 5000 / 6000 can be mounted in a better position with better ventilation. Page 20 WB50_60-11:FE4105 Operating instructions
21 Insulation fault The green LED blinks once per second. Unit description The Windy Boy 5000 / 6000 indicates a ground fault by illuminating the red LED. The red LED is continuously on. Consult trained electrical personnel to correct the fault using the "Installation manual". Defective varistor The green LED is continuously on. The red LED is continuously on. At least one of the two thermally monitored varistors on the DC input side of the device has become highly resistive and thus no longer functions correctly. Consult trained electrical personnel to correct the fault using the "Installation manual". Constant operational limiting The yellow LED is continuously on. This message is displayed if a fault develops in the grid monitoring and/or the independent disconnection device (SMA grid guard). The Windy Boy 5000 / 6000 has detected a fault in the SMA grid guard during an internal test and has disabled the mains supply feed-in. This usually indicates a fault that cannot be corrected on site. Please consult the manufacturer (chapter 12 "Contact (page 67)) and discuss further action to solve the problem with them. Operating instructions WB50_60-11:FE4105 Page 21
22 Unit description Mains supply fault The yellow LED illuminates 2 times LED on LED off 1 2 5s 3s 1s The message is repeated 3 times and then begins again. The yellow fault LED illuminates for 5 seconds when the fault occurs, and then begins displaying the blink code of: 3 seconds off and then 2 times briefly on. This code is displayed three times in succession. If the fault is still present, the fault display starts again from the beginning. The Windy Boy 5000 / 6000 indicates a mains supply fault with this message, which can have the following causes: Low mains supply voltage (VAC < "Vac-Min") High mains supply voltage (VAC > "Vac-Max") Low mains supply frequency (fac < "Fac-Min") High mains supply frequency (fac > "Fac-Max") A change in mains supply frequency ("dfac") Check if a general mains supply dropout has occurred (check the operation of other mains supply devices), and check if the fuse of the feed-in connection of the Windy Boy 5000 / 6000 is intact. If one of these faults can be found, then the mains supply connection of the Windy Boy 5000 / 6000 must be checked by qualified electrical personnel. Page 22 WB50_60-11:FE4105 Operating instructions
23 Unit description Mains supply impedance is too high The yellow LED illuminates 3 times LED on LED off s 3s 1s The message is repeated 3 times and then begins again. The yellow fault LED illuminates for 5 seconds when the fault occurs, and then begins displaying the blink code of: 3 seconds off and then 3 times briefly on. This code is displayed three times in succession. If the fault is still present, the fault display starts again from the beginning. The Windy Boy 5000 / 6000 has detected a fault relating to an unacceptable impedance in the mains supply. If the Windy Boy 5000 / 6000 frequently displays this fault during mains monitoring, the cause can be a mains impedance that is too high. An electrician can usually assist with this problem by increasing the cross section of the mains connection cable. Other measures can be taken to correct this problem, but they require the agreement and cooperation of the electricity supplier. Input voltage too high The yellow LED illuminates 4 times LED on LED off s 3s 1s 1s 1s 1s The message is repeated 3 times and then begins again. The yellow fault LED illuminates for 5 seconds when the fault occurs, and then begins displaying the blink code of: 3 seconds off and then 4 times briefly on. This code is displayed three times in succession. If the fault is still present, the fault display starts again from the beginning. Immediately disconnect the DC input of the Windy Boy 5000 / The presence of excessive input voltage can lead to irreparable damage! Make sure that the input voltage never exceeds 600 V. Operating instructions WB50_60-11:FE4105 Page 23
24 Unit description When the Windy Boy 5000 / 6000 receives an excessive DC input voltage, it automatically disconnects from the mains supply and no longer feeds power into the grid. When the Windy Boy 5000 / 6000 is in operation, you must always first disconnect the AC voltage (mains supply) and only then should you disconnect the DC voltage from the Windy Boy 5000 / 6000! Device faults The yellow LED illuminates 5 times LED on LED off s 3s 1s 1s 1s 1s The message is repeated 3 times and then begins again. The yellow fault LED illuminates for 5 seconds when the fault occurs, and then begins displaying the blink code of: 3 seconds off and then 5 times briefly on. This code is displayed three times in succession. If the fault is still present, the fault display starts again from the beginning. If the device fault leads to a major reduction in normal operation, the Windy Boy and the entire system installation should be checked by an electrician. Page 24 WB50_60-11:FE4105 Operating instructions
25 Netzwechselrichter für Windenergieanlagen Grid tied inverter for wind turbines Unit description 3.4 Messages in the optional display The Windy Boy 5000 / 6000 can be factory fitted with an LCD display in the lid of the case. Windy Boy The display can also be retrofitted (SMA order code, "SB-Display", language specification to be provided when ordering). Switching on the display illumination The background illumination is switched on by tapping on the lid of the case. Tapping again switches the display to the next message. After 2 minutes, the illumination switches off automatically. Display messages in the startup phase The following messages are displayed during the startup phase of the Windy Boy 6000 and are identical to those in the Windy Boy Since the Windy Boy 5000 / 6000 is identically to the Sunny Mini Central, apart from the mode of operation, the display shows "Sunny Mini Central. After 6 seconds, the firmware version of the operation control unit (BFR) and the current control unit (SRR) are displayed. SMC6000 WR6K-003 Initialization phase BFR Version 2.52 SRR Version 2.49 Initialization phase Operating instructions WB50_60-11:FE4105 Page 25
26 Unit description Display message during operation The display shows the most important operational information of the Windy Boy 5000 / 6000 in a continuous cycle. The following three diagrams serve to clarify the messages. Every message is displayed for 5 seconds. Then the cycle begins again. E-today 3.86 Status Turbine Energy sum since the last activation, and the current operational status The energy generated today and the current operational status are first displayed. The amount of energy shown under "E-today" does not necessarily reflect the amount of energy produced over the last 24 hours. This is rather the energy produced by the Windy Boy 5000 / 6000 since the last deactivation/ activation. Pac Vac Fault displays 903W 195V Current feed-in power and AC voltage E-total 724.4kWh h-total 512h Total amount of energy produced and the total number of operating hours Disturbance Vac-Bfr Fault display Subsequently, the current feed-in power and the output voltage are displayed. This is then followed by the total energy produced so far and the operational hours of the device. If an operational fault develops, the display immediately switches to "Disturbance" and the background illumination is switched on. The cause of the fault is displayed for 5 seconds in the second line of the display. at: present: 261V 245V Display of the values measured during the fault If a measured value is responsible for the fault condition, then the value measured at the time of the fault is displayed. If another measurement is possible, the current value is displayed in the second line. After another 5 seconds, normal operational information is again displayed. If the fault is still present, the fault display starts again from the beginning. An overview of the status and fault messages can be found in chapter 10.2 "Fault messages (page 60) of this document. Page 26 WB50_60-11:FE4105 Operating instructions
27 Error ROM indicates, that the Windy Boy 5000 / 6000 has recognized a fault in the Firmware EEPROM. Contact SMA to correct the fault. Special display in the case of excessive DC input voltage If an excessive DC input voltage is present on the Windy Boy 5000 / 6000, then this is indicated by rapid blinking of the background illumination and a corresponding message. Error ROM Unit description Fault displays of the Firmware EEPROM!PV-Overvoltage! DISCONNECT DC Overvoltage displays Immediately disconnect the DC input of the Windy Boy 5000 / The presence of excessive input voltage can lead to irreparable damage! Make sure that the input voltage never exceeds 600 V. When the Windy Boy 5000 / 6000 receives an excessive DC input voltage, it automatically disconnects from the mains supply and no longer feeds power into the grid. When the Windy Boy 5000 / 6000 is in operation, you must always first disconnect the AC voltage (mains supply) and only then should you disconnect the DC voltage from the Windy Boy 5000 / Before placing the device back into operation, the input voltage must be checked before reconnecting the DC voltage to the Windy Boy 5000 / 6000! Since the Windy Boy 5000 / 6000 is identical to the Sunny Mini Central, apart from the mode of operation, the display of the Windy Boy 5000 / 6000 shows "PV" (Photovoltaic) as its input source. Operating instructions WB50_60-11:FE4105 Page 27
28 Unit description Page 28 WB50_60-11:FE4105 Operating instructions
29 MC MC C B A Potter & Brumfield Potter & Brumfield Potter & Brumfield MC MC MC MC A S2 B A MC S1 B MC 0 V SMC60-AST Setting the display language 4 Setting the display language The display language is set using the switches on the underside of the SB-LCD components. Since the cover must be removed, please ask a qualified electrician to disconnect the DC and AC connections from the Windy Boy 5000 / 6000, according to the installation instructions. Position of the switches for setting the display language V VN30.15/00858 N L PE 230 Vac: N L1 Language Switch S2 Switch S1 German B B English B A French A B Spanish A A A S2 B A S1 B Operating instructions WB50_60-11:FE4105 Page 29
30 Setting the display language Page 30 WB50_60-11:FE4105 Operating instructions
31 Maintenance and care 5 Maintenance and care Because the Windy Boy 5000 / 6000 can be used outdoors in places that are difficult to access, it has been constructed for low maintenance. In the interests of maximum yield, the operator should check, weekly if possible, under various conditions of wind, if the displays of the Windy Boy 5000 / 6000 indicate plausible normal operation (cf. chapter "Description of the operational status" (page19)). Naturally, this information can be obtained by using one of the communications options. The cleaning intervals are dependent from the ambient conditions. Make sure that enough air can flow through the fan guards. With that you can contribute to an optimum yield of your system. If the LEDs are so dirty that they can no longer be seen, then they can be cleaned with a damp cloth. Solvents, abrasives or corrosive liquids must not be used! A detailed description of how to clean the fans can be found in the installation manual of the Windy Boy 5000 / Operating instructions WB50_60-11:FE4105 Page 31
32 Maintenance and care Page 32 WB50_60-11:FE4105 Operating instructions
33 Turbine operation 6 Turbine operation 6.1 Overview The Windy Boy 5000 / 6000 is a single phase inverter that converts DC current into AC current and feeds the energy generated by a wind turbine into an existing mains supply. The Windy Boy 5000 / 6000 is externally identical to the Sunny Mini Central inverter for photovoltaic systems. The Windy Boy 5000 / 6000 inverter has a special operational mode for wind generators however, which allows performance adjustment to the characteristic curves of many different manufacturers' generators ("Turbine" operating mode). In this way maximum yields can be obtained from your wind turbine. The mechanical power of the wind turbine is presented to the Windy Boy in the form of a direct, rotation speed variable DC voltage (RPM) and current intensity (torque). Most small wind turbines have a so-called permanent magnet generator and a downstream rectifier for converting the variable frequency AC generator voltage into DC current. 6.2 Characteristic curve function The "Turbine" operating mode of the Windy Boy 5000 / 6000 uses a programmable power/voltage curve to regulate the input current depending on the generator voltage (V/I characteristic curve). Every wind generator is designed to have an optimum working point for voltage and current, at different rotational speeds or wind speeds. This behavior is not linear. The Windy Boy 5000 / 6000 uses an approximation based on a simple ramp function. The function can be programmed by the user so that it comes close to the behavior of the wind generator being used and thus provides power adaptation. Operating instructions WB50_60-11:FE4105 Page 33
34 Turbine operation The diagram shows the ramp function of a typical Windy Boy 5000 / 6000 power/ voltage curve. The feed-in AC power depending on the DC input voltage of the Windy Boy is shown here. The adjustable parameters U PV Start, U DC WindStart and U DC WindMax are used to adapt the power/voltage curve of the Windy Boy 5000 / 6000 to the wind generator being used. Operating Mode: Turbine Pac / Pac-max Vdc V The correct configuration of the parameters shown in the diagram is absolutely necessary to guarantee optimum operation with wind generators from different manufacturers. The basic parameters of a Windy Boy 5000 / 6000 (factory settings) are shown in the following table. Page 34 WB50_60-11:FE4105 Operating instructions
35 Turbine operation Name WB 5000 WB 6000 Unit Description UpvStart V DC ( ) ( ) UdcWindStart 330 ( ) UdcWindMax 550 ( ) 330 ( ) 550 ( ) Defines the voltage at the moment when the Windy Boy 5000 / 6000 is ready to perform a mains supply synchronization. The correct configuration of the parameters above is absolutely necessary to guarantee optimum operation with generators from different manufacturers. Preconditions for changing the operating parameters are described in chapter 6.4 "General setting example (page 37). V DC V DC P-Wind-Ramp W/sec ( ) ( ) T-Start 10 ( ) T-Stop 2 ( ) 10 ( ) 2 ( ) Defines the voltage at the moment when the Windy Boy 5000 / 6000 is ready to begin feeding power into the mains supply. Defines the voltage at the moment when the Windy Boy 5000 / 6000 begins feeding maximum power into the mains supply. Controls a delayed startup of the characteristic curve, only after the Windy Boy 5000 / 6000 has been switched on. This avoids the generator being suddenly presented with a heavy load. sec Start Timer Mains synchronization. sec Stop Timer Aborting the supply of power and switching off. To perform the configuration process, the DC input voltage must be greater than <UpvStart> and the Windy Boy 5000 / 6000 must be connected to the mains supply. Operating instructions WB50_60-11:FE4105 Page 35
36 Turbine operation 6.3 Characteristic curve operation in "Turbine" operating mode Please note: The linear characteristic curve of the Windy Boy 5000 / 6000 only approximates the actual characteristics of a real wind generator. Consult the manufacturer of your wind generator for the typical characteristics of your generator before changing the characteristic curve parameters. As soon as the DC input voltage defined in the parameter <UpvStart> is reached, the Windy Boy begins a number of self tests, measurement processes and synchronizes with the mains supply. If the self tests are successfully completed, and the DC input voltage remains above the value defined in <UpvStart> for the time defined in <T- Start>, the Windy Boy connects to the mains supply. As soon as the DC input voltage reaches the value defined in <UdcWindStart>, the Windy Boy begins feeding power into the mains supply. As you can see from the characteristic curve, the power fed into the mains supply rises with the DC input voltage. As soon as the DC input voltage reaches the value defined in the parameter <UdcWindMax>, the Windy Boy 5000 / 6000 feeds the mains supply with the maximum possible power. If the input voltage continues to rise, the Windy Boy 5000 / 6000 continues to feed the mains supply at maximum power. The characteristic curve ends at the maximum permissible input voltage of the Windy Boy 5000 / 6000, which must never be exceeded. If the wind strength is so low that the DC input voltage falls below <UpvStart>, then the Windy Boy ceases feeding power into the mains supply for the period defined in <T-Stop>. If the DC input voltage increases again, then the Windy Boy will again operate according to the characteristic curve. If the DC input voltage falls below the internally calculated minimum operating value of <Vmin>, then there is insufficient energy for the on-board electronics and the Windy Boy will switch off. If the DC input voltage lies between <Vmin> and <UpvStart> for the time defined by <T-Stop>, then the Windy Boy will also switch off. After the switch-off process, the whole process begins anew. Only change the operating parameters when you know exactly what you are doing! Page 36 WB50_60-11:FE4105 Operating instructions
37 Turbine operation 6.4 General setting example Please note that the following example only represents a starting point for operating with a wind generator. <UpvStart> is set to the lowest possible value: This achieves an early switch-on of the Windy Boy 5000 / <UdcWindStart> is set to the same value of <UpvStart>: This achieves an early mains supply feed-in. If the wind turbine does not properly start, or the Windy Boy frequently switches on and off, it is recommended that you increase <UdcWindStart> in (e.g.) 10 V steps. <UdcWindMax> is initially set to approx. 10 % below the maximum MPP voltage of the Windy Boy 5000 / 6000: In this case the slope of the ramp function is relatively flat. The maximum output power is only reached with a relatively high DC input voltage, which avoids "braking" of the wind generator through excessive power consumption. This setting is especially suitable in locations with little or weak wind. Once the properties of the wind generator are known, then the reduction of the <UdcWindMax> parameter may be necessary, in order to extract the maximum power from the wind generator even at low DC input voltages (low wind speeds). The ramp function will then be steeper. Contact the manufacturer of your wind generator for the typical properties of your generator (voltage/power characteristic). <T-Stop> is set to the maximum value: Here, the Windy Boy remains connected to the mains supply, even at low DC input voltage levels, and "waits" for the next gust of wind. This delays an early switch-off of the Windy Boy. <T-Start> is set to the minimum value: This achieves a reduction of the switch-on time (please observe the regulations of the energy supplier responsible). Only change the operating parameters when you know exactly what you are doing! Operating instructions WB50_60-11:FE4105 Page 37
38 Turbine operation Page 38 WB50_60-11:FE4105 Operating instructions
39 Maintenance and care 7 Maintenance and care Because the Windy Boy 5000 / 6000 can be used outdoors in places that are difficult to access, the Windy Boy has been constructed for low maintenance. To guarantee safe operation, it is usually adequate to check the device visually for damage approximately every two months. It should also be checked if the red LED is illuminated and, if necessary, remove the fault by referring to chapter "Description of the operational status (page 19). In the interests of maximum yield, the operator should check, weekly if possible, under various conditions of solar irradiation, if the displays of the Windy Boy 5000 / 6000 indicate plausible normal operation (cf. chapter "Description of the operational status (page 19)). Naturally, this information can be obtained by using one of the communications options. Cleaning of the Windy Boy is only necessary when the heat dissipation is limited by dirty cooling fins or a dirty space between the Windy Boy and the wall. The dirt should be carefully removed with an appropriate soft brush or paintbrush. If the LEDs are so dirty that they can no longer be seen, then they can be cleaned with a damp cloth. Solvents, abrasives or corrosive liquids must not be used! Operating instructions WB50_60-11:FE4105 Page 39
40 Maintenance and care Page 40 WB50_60-11:FE4105 Operating instructions
41 Expansions 8 Expansions As with all inverters in the Sunny Boy family, the Windy Boy 5000 / 6000 can also be expanded with a range of communications interfaces. This provides the operator with the possibility of requesting detailed operational data and error messages, for subsequent analysis on a PC using (e.g.) the free software available from SMA. The data can currently be transferred in five different ways: using Powerline using a separate RS485 cable using a separate RS232 cable using a wireless link (Sunny Beam) using a separate USB-Service-Interface (USBPBS) The wind turbine can be monitored by the Windy Boy 5000 / 6000 in a number of different ways. SMA offers a range of products for this purpose, allowing you to install a tailor-made monitoring system for your system. If you require detailed information about the Windy Boy products, please request the Sunny Family catalog or visit In the following sections the currently available communications options are schematically described. 8.1 Sunny Data Sunny Data is a PC program for direct monitoring of your system. The connection of the Windy Boys to a PC is described in the following sections. Operating instructions WB50_60-11:FE4105 Page 41
42 Photovoltaik-Wechselrichter Photovoltaic inverter Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Betrieb Operation Erdschluss Earth Fault Störung Failure Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Expansions 8.2 Sunny Data via Powerline "Wireless" communication via the mains power line (up to 50 Windy Boys) Prerequisites: The Windy Boys must be equipped with a Powerline Piggy-Back and the PC must be equipped with an SWR-COM plug modem. The connection of the PC using SWR-COM is described in the SWR-COM documentation. SWR-COM socket connector PC with Sunny Data Control max. 50 Powerline 8.3 Sunny Data over RS232 Communication via a cable (a single Windy Boy 5000 / 6000) Prerequisites: The Windy Boy must be equipped with an RS232 Piggy-Back, the connection to the PC usually occurs directly over the COM1 or COM2 port of the PC. The installation of the RS232 cable is described in the installation instructions of the Windy Boy 5000 / PC with Sunny Data Page 42 WB50_60-11:FE4105 Operating instructions
43 Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Photovoltaik-Wechselrichter Photovoltaic inverter Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Betrieb Operation Erdschluss Earth Fault Störung Failure Störung Failure Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Expansions 8.4 Sunny Data over RS485 Communication via a cable (up to 50 Windy Boys) Prerequisites: All Windy Boys must be equipped with an RS485 Piggy-Back, the connection with the PC usually occurs via an RS485/RS232 interface converter connected to the COM1 or COM2 port or via an RS485/USB interface converter connected to the USB port. The installation of the RS232 cable is described in the installation instructions of the Windy Boy 5000 / Interface Converter (RS485/RS232 PC with Sunny Data max. 50 RS232 RS Sunny Beam Simple wireless system monitoring for up to 4 Windy Boys. Prerequisites: The Windy Boys must be equipped with a wireless Piggy-Back and a Sunny Beam must be present at an appropriate distance. The installation of the wireless Piggy-Back is described in the Sunny Beam user manual. Sunny Beam max. 4 Operating instructions WB50_60-11:FE4105 Page 43
44 Photovoltaik-Wechselrichter Photovoltaic inverter Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Betrieb Operation Erdschluss Earth Fault Störung Failure Photovoltaik-Wechselrichter Photovoltaic inverter Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Betrieb Operation Erdschluss Earth Fault Störung Failure Photovoltaik-Wechselrichter Photovoltaic inverter Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Betrieb Operation Erdschluss Earth Fault Störung Failure PAC 1273 W Expansions 8.6 Sunny Data Control over Sunny Beam Communication with a PC over Sunny Beam (up to 4 Windy Boys) Prerequisites: All 4 Windy Boys must be equipped with a wireless Piggy-Back and accessible to Sunny Beam for system monitoring. The Sunny Beam is connected to the PC via an USB cable. The installation of the wireless Piggy-Backs and the connection to the PC is described in the Sunny Beam user manual. Sunny Beam PC with Sunny Data max. 4 USB 8.7 Sunny Boy Control Light The simple data logger for systems with up to 10 Windy Boys. The connection between the Sunny Boy Control Light and the Windy Boys occurs via Powerline. Prerequisites: The Windy Boys must be equipped with a Powerline Piggy-Back. The installation is described in detail in the Sunny Boy Control Light documentation. Sunny Boy Control Light max. 10 Powerline Page 44 WB50_60-11:FE4105 Operating instructions
45 Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Photovoltaik-Wechselrichter Photovoltaic inverter Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Betrieb Operation Erdschluss Earth Fault Störung Failure Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure PAC 1273 W PAC 1273 W Expansions 8.8 Sunny Boy Control The simple data logger for systems with up to 50 Windy Boys. The connection between the Sunny Boy Control and the Windy Boys can be achieved as follows: Powerline - "Wireless" communication via the mains power line Prerequisites: All the Windy Boys must be equipped with a Powerline Piggy-Back. Sunny Boy Control max. 50 Powerline RS485 Communication via a cable Prerequisites: All Windy Boys must be equipped with an RS485 Piggy-Back, the Sunny Boy Control must be equipped with an RS485 Piggy-Back on the "COM1 - Sunny Boy" interface. Sunny Boy Control max. 50 RS Sunny Boy Control Plus The data logger for systems with up to 50 Windy Boys, an additional interface for connection to PCs or large displays and additional connection possibilities for digital and analog inputs and outputs. Prerequisites: See Sunny Boy Control. Operating instructions WB50_60-11:FE4105 Page 45
46 Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Expansions 8.10 Sunny Data Control This is a PC program for system monitoring and visualization on a PC for systems with a Sunny Boy Control. Prerequisites: A system with a Sunny Boy Control, Sunny Boy Control Plus or Sunny Boy Control Light with a connection to a PC. Connection also possible via Modem Visualization with Sunny Data Control Internet presentation with SDC-Agent.. Internet presentation with SMA-Portal Data evaluation with Excel Remote Desktop The connection between the PC and the Sunny Boy Control can occur via modem if required. Large systems with more than 50 Windy Boys can be monitored by coupling several Sunny Boy Controls together. Page 46 WB50_60-11:FE4105 Operating instructions
47 Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Expansions 8.11 Sunny WebBox The Sunny WebBox is a versatile inexpensive platform for system visualization directly on a PC or via the Internet using the Sunny Portal. The Sunny WebBox will be available from the 2nd quarter of Telephone Connection PC via Modem. RS485 ( RS232*) ( Powerline*) (Radio*) Sunny WebBox Sunny Portal (Internet) Memory Card Hub LAN External Display External Sensors LAN LAN PC LAN * Communication with Sunny WebBox via RS232, Powerline or using a wireless link will be possible at the end of 2005 or later. Operating instructions WB50_60-11:FE4105 Page 47
48 Photovoltaik-Wechselrichter Photovoltaic inverter Photovoltaik-Wechselrichter Photovoltaic inverter Photovoltaik-Wechselrichter Photovoltaic inverter Betrieb Operation Erdschluss Earth Fault Störung Failure Betrieb Operation Erdschluss Earth Fault Störung Failure Betrieb Operation Erdschluss Earth Fault Störung Failure Pac = 7,450 W Sunny TV Expansions 8.12 Sunny Portal The Sunny Portal is a high performance interface from SMA for the monitoring and presentation of your system in the Internet. Details can be obtained from the Sunny Family catalog or directly under PORTAL.de Sunny TV Sunny TV is an accessory for Windy Boy inverters, which displays the system data and the current performance on a monitor or video projector. It is suitable for the presentation of large systems in lobbies and entrance halls as well as in private areas. Video Projector TV Set Sunny TV Sunny TV Pac = 7,450 W. RS485 ( RS232*) ( Powerline*) (Radio*) Sunny TV Video-Out PC Monitor Sunny TV Pac = 7,450 W Configuration with PC * Communication with Sunny TV via RS232, Powerline or using a wireless link will be possible at the end of 2005 or later. Page 48 WB50_60-11:FE4105 Operating instructions
49 Technical data 9 Technical data 9.1 Windy Boy DC connection data Max. input open circuit voltage V DC V Input voltage, MPP range V DC 246 V V DC Nominal DC operating voltage V DC nom 270 V Max. input current I DC max 26 A Max. input power P DC max 5750 W Recommended generator power P turb max 4000 W at 5,000 full-load hours / year Recommended generator power P turb max 4500 W at 2,500 full-load hours / year All-pole isolator on the DC input DC plug connector side Overvoltage protection Thermally monitored varistors DC voltage ripple U SS < 10% of the input voltage Personal protection Insulation monitoring (Riso > 1 MΩ) Own consumption in standby < 7 W (standby) mode Reverse polarity protection Short circuit diode Operating instructions WB50_60-11:FE4105 Page 49
50 Technical data Grid connection data Nominal output power P ACnom 5000 W Peak output power P ACmax 5500 W Nominal output current I ACnom 21,7 A Harmonic distortion of output THD IAC < 4 % (P AC > 0.5 P ACnom ) current Operating range, grid voltage V AC V AC ( V AC programmable) Operating range, grid frequency All-pole isolator grid side Phase shift angle (based on the current's fundamental frequency) Overvoltage category Test voltage (50 Hz) Test surge voltage Own consumption in standby mode f AC cos j Hz / Hz ( Hz programmable) Independent disconnection device (SMA grid guard) III 2 kv (1 s routine testing / 60 s type testing) 4 kv (1.2 / 50 µs) type testing (serial interface: 6 kv) 0.25 W Page 50 WB50_60-11:FE4105 Operating instructions
51 Technical data General data For a detailed description of the device, see chapter 3 "Unit description (page 13) of this manual. General data Protection category per DIN EN External temperature range Dimensions (w x h x d) Weight IP54-25 C to +60 C 430 mm x 600 mm x 450 mm 63 kg (approx.) External interfaces Data transfer (mains cable) Data transfer (data cable) Data transfer (wireless) Optional optional, RS232 / RS485, electrically separated Optional Efficiency Max. efficiency η max > 95,6 % The efficiency of the Windy Boy 5000 / 6000 is heavily dependent on the DC input voltage. Overall Efficiency [%] V 300 V 400 V 500 V Windy Boy Output Power [W] Operating instructions WB50_60-11:FE4105 Page 51
52 Technical data 9.2 Windy Boy DC connection data Max. input open circuit voltage U DC V Input voltage, MPP range U DC 246 V V DC Nominal DC operating voltage U DC nom 270 V Max. input current I DC max 26.0 A Max. input power DC max 6300 W Recommended generator power P turb max 4400 W at 5,000 full-load hours / year Recommended generator power P turb max 4950 W at 2500 full-load hours / year All-pole isolator on DC plug connector the DC input side Overvoltage protection Thermally monitored varistors Voltage ripple U PP < 10% of the input voltage Personal protection Insulation monitoring (Riso > 1 MΩ) Own consumption in standby < 7 W mode Reverse polarity protection Short circuit diode Page 52 WB50_60-11:FE4105 Operating instructions
53 Technical data Grid connection data Nominal output power P ACnom 5500 W Peak output power P ACmax 6000 W Nominal output current I ACnom 24.0 A Harmonic distortion of output current (at K Unom < 2 %, P AC > 0.5 P ACnom ) THD IAC < 4 % Operating range, grid voltage V AC V AC ( V AC programmable) Operating range, grid frequency f AC Hz / Hz ( programmable) All-pole isolator grid side Independent disconnection device (SMA grid guard) Phase shift angle (based on the current's fundamental frequency) cos j 1 Overvoltage category Test voltage (50 Hz) Test surge voltage Own consumption in standby mode III 2 kv (1 s routine testing / 60 s type testing) 4 kv (1.2 / 50 µs) type testing (serial interface: 6 kv) 0.25 W Operating instructions WB50_60-11:FE4105 Page 53
54 Technical data General data For a detailed description of the device, see chapter 3 "Unit description (page 13) of this manual. General data Protection category per DIN EN Dimensions (w x h x d) Weight IP mm x 600 mm x 450 mm 63 kg (approx.) External interfaces Data transfer (mains cable) Optional Data transfer (separate data cable) optional, RS232 / RS485, electrically separated Data transfer (wireless) Optional Efficiency Max. efficiency η max > 96,0 % The efficiency of the Windy Boy 5000 / 6000 is heavily dependent on the DC input voltage. The lower the input voltage, the higher the efficiency. Overall Efficiency [%] V 300 V 400 V 500 V Windy Boy Output Power [W] Page 54 WB50_60-11:FE4105 Operating instructions
55 General information 10 General information 10.1 Measurement channels and messages If your Windy Boy 5000 / 6000 is equipped with a communications component, then numerous measurement channels and messages can be consulted. These can be useful for both performance improvement and for fault prevention. The following abbreviations apply: BFR: Operation control unit SRR: Current control unit E-Total Fac Fehler / Error h-total Iac-Ist Ipv Netz-Ein / Power on Pac Riso Seriennummer / Serial number Status / State Uac / Vac Upv-Ist / Vpv Upv-Soll / Vpv-Setpoint Zac Total amount of feed-in energy Grid frequency Fault type display under "Disturbance" status Total hours of mains supply feed-in operation Mains supply current DC current Total number of mains supply switch-ons Mains supply performance provided Insulation resistance of the system to the mains supply connection Serial number of the Windy Boy Display of the current operational status Grid voltage DC input voltage Nominal DC voltage Mains supply impedance The measurement channels provide information in German (e.g."fehler ), or in English (e. g. "Error ), depending on which software you are using (Sunny Data or Sunny Data Control). Operating instructions WB50_60-11:FE4105 Page 55
56 General information Status messages The Windy Boy 5000 / 6000 produces a range of status messages, depending on the mode in which it is currently operating. The status messages can vary, depending on the type of communications system you are using. Derating Overtemperature in inverter ("WR"). The Windy Boy 5000 / 6000 reduces its performance to avoid overheating the device. To avoid unnecessary yield losses, the configuration and string size should be checked. Check if the Windy Boy 5000 / 6000 can be located in a better position with better ventilation, thus providing better heat dissipation. Mpp The Windy Boy 5000 / 6000 is operating in MPP mode. The Windy Boy 5000 / 6000 takes the highest possible performance from the PV generator. MPP is the standard display when operating with normal sunshine (PV operation only). Island Mode The Windy Boy 5000 / 6000 is in Island Mode. This mode is specially conceived for operation in a stand alone power system with a Sunny Island as network controller. More information about this topic can be obtained from the Sunny Island operating manual under the category "Droop Mode". grid mon. Testing the mains supply status (mains impedance), relay tests etc. This message appears only during the startup phase, before the Windy Boy 5000 / 6000 is connected to the mains supply. This message mainly appears when there is little or no wind. Offset Offset compensation of the measurement electronics disturb. Fault (see table "Fault messages") This fault occurs for reasons of safety and prevents the Windy Boy 5000 / 6000 from connecting to the mains supply. This mode can also be manually set. Stop Interruption of operation after a fault. This status can also be manually set. Turbine Mode Default setting for Windy Boy 5000 / 6000 inverters. The input voltage is converted according to the V/I function U PV Start, U DC Start and U DC WindMax. See chapter 6 "Turbine operation (page 33). V-Const Constant voltage operation (the input voltage is predefined. The Windy Boy 5000 / 6000 operates in neither MPP mode nor Turbine mode). In some cases, this can be set as the operational mode. waiting The switch-on conditions are not (yet) satisfied. Page 56 WB50_60-11:FE4105 Operating instructions
57 General information Windy Boy 5000 / 6000 Operating parameters Unauthorized changes to the operating parameters may result in: Injury or accidents as a result of changing the internal safety routines in the Windy Boy 5000 / 6000, Voiding of the Windy Boy 5000 / 6000 operating approval certificate Voiding of the Windy Boy 5000 / 6000 warranty Never change the parameters of your Windy Boy 5000 / 6000 without explicit authorization and instructions. Name Unit Value range (WB 5000 / WB 6000) Betriebsart / Operating Mode MPP UKonst Stop Turbine Mode Insel Mode Factory settings (WB 5000 /WB 6000) Turbine Description Operating mode of the Windy Boy 5000 / 6000: MPP: Maximum Power Point UKonst: Constant voltage mode (Desired voltage is defined in "Usoll- Konst") Stopp: Disconnection from mains supply, no operation Turbine: Operating mode for wind turbines, the input voltage is converted according to the V/I function defined by U PV Start, U DC WindStart and U DC WindMax. Default GER/ENS Used for setting the country specific information. dfac-max Hz/s ,0 0,25 Maximum "Mains frequency change" before the mains monitoring system disconnects the device from the mains supply. dzac-max mohm Maximum "Mains impedance change" before the mains monitoring system disconnects the device from the mains supply. E_Total kwh Total energy yield (E_Total) and total h_total h hours of operation (h_total) for the Windy Boy. This change may be necessary when you exchange your Windy Boy 5000 / 6000 and want to use the data from the old device. Fac-delta- Hz ,5 0,19 Maximum frequency, above (Fac- Fac-delta+ Hz ,5 0,19 Delta+) and below (Fac-Delta-) the mains frequency of 50 Hz, before the mains monitoring system disconnects the device from the mains supply. Operating instructions WB50_60-11:FE4105 Page 57
58 General information Name Unit Value range (WB 5000 / WB 6000) I-NiTest ma Activation (16000) and deactivation (0) of the automatic leakage current measurement. This parameter only functions when the Windy Boy is deactivated (disconnected on the AC side) or in "Stop" mode. Inst.-Code Parameters for mains supply monitoring can only be changed after entering the "SMA grid guard" password. KI-Wind-Reg ,25 0,005 Control speed (only possible in Turbine mode!) KP-Wind-Reg ,25 0,117 Control speed (only possible in Turbine mode!) P-Wind-Ramp W/s Slow startup during mains supply connection (only possible in Turbine mode!) Speicher-- funktion / Memory function Speichern/ store Default, Parameter, Reset Betriebsdaten, Reset Fehler Permanent, volatile none Default parameter: Returns all parameter values to the factory setting. Reset Betriebsdaten: Returns all user level parameter values to the factory setting. Reset Fehler: Resets a permanent fault. Permanent Permanent: Modified parameters are stored in the EEPROM and can be used even when the Windy Boy has been restarted. Volatile: Prevents the parameters from being stored in the EEPROM, the parameters are stored until the next restart. T-Start sec Start timer for mains supply synchronization. (only possible in Turbine mode!) T-Stop sec Stop timer for stopping operation and switching off. (only possible in Turbine mode!) Uac-Min / Vac-Min Uac-Max / Vac-Max Factory settings (WB 5000 /WB 6000) Description V Lower (Uac-Min) and upper (Uac-Max) limits of the acceptable AC voltage (self V contained power system recognition). U DC WindMax V U DC WindMax represents the highest point of the function (please read more about this topic in chapter 6 "Turbine operation (page 33)). (only possible in Turbine mode!) Page 58 WB50_60-11:FE4105 Operating instructions
59 General information Name Unit Value range (WB 5000 / WB 6000) U DC WindStart V U DC WindStart represents the lowest point of the function (please read more about this topic in chapter 6 "Turbine operation (page 33)). (only possible in Turbine mode!) Usoll-Konst / Vconst- Setpiont V Desired DC voltage for constant operational voltage. These parameters are only important when the "Betriebsart" parameter is set to U- Konst. U PV Start V U PV Start is the parameter defining the voltage at which the Windy Boy is capable of connecting to the system. 180 V is the recommended voltage for the Windy Boy 5000 and the Windy Boy Reducing this voltage parameter can lead to numerous unnecessary connection attempts. Increasing this voltage parameter can lead to energy losses since the Windy Boy does not immediately connect to the system. The following parameters are displayed in the parameter list but cannot be modified: Name Unit Value range (WB5000/ 6000) Factory settings (WB5000/ 6000) Description Plimit W 5000 / / 6000 Upper limit for AC output power SMA-SN Serial number of the Windy Boy 5000 / 6000 Software-BFR / Firmware-BFR Software-SRR / Firmware-SRR Factory settings (WB 5000 /WB 6000) Description Firmware version of the operation control unit (BFR) Firmware version of the current control unit (SRR) Operating instructions WB50_60-11:FE4105 Page 59
60 General information 10.2 Fault messages If a fault develops, the Windy Boy 5000 / 6000 generates a message, which is dependent on the operational mode and the type of fault. Fault code Bfr-Srr NUW-FAC NUW-UAC NUW-ZAC dzac-bfr dzac-srr EEPROM EEPROM dbh EeRestore Fac-Bfr Fac-Srr Description Internal measurement comparison fault: the Windy Boy 5000 / 6000 found a too large difference between values provided by the BFR and SRR. Contact SMA. The changes in mains impedance exceed the permissible range ("Bfr" or "Srr" is an internal message that has no meaning for the user). The Windy Boy 5000 / 6000 disconnects from the mains supply or stand-alone grid, to avoid potential damage. If possible, check the mains impedance and check how often major deviations occur. If repeated variations occur and this is causing "dzac-bfr" or "dzac- Srr" faults, ask the electricity provider if they agree to a modification of the operating parameters. Discuss the proposed parameters with the SMA hotline. A data transfer fault occurred during reading or writing of data from the EEPROM. The data is not relevant for safe operation - this fault has no effect on performance. Data EEPROM is defective. The device has switched itself off because the loss of important functions has disabled the Windy Boy 5000 / Contact SMA. One of the duplicate data sets in the EEPROM is defective and has been reconstructed without loss of data. The mains frequency has exceeded the permissible range ("Bfr" or "Srr" is an internal message that has no meaning for the user). The Windy Boy 5000 / 6000 disconnects from the mains supply or standalone grid, to avoid potential damage. Check the mains frequency and mains connections on the Windy Boy 5000 / If the mains frequency lies outside the permissible range because of local conditions, ask the electricity provider if they agree to a modification of the operating parameters. If the mains frequency lies within an acceptable range and "Fac-Bfr" or "Fac-Srr" faults are still being displayed, please contact the SMA hotline. Page 60 WB50_60-11:FE4105 Operating instructions
61 General information Fault code Imax K1-Schliess / K1-Close K1-Trenn / K1-Open NUW-Mes Offset Rechner / NuW- Timeout Riso ROM Uac-Bfr / Vac-Bfr Uac-Srr / Vac-Srr Description Overcurrent on the AC side. This fault code is displayed if the current in the AC network is larger that specified. Check your system configuration and the mains supply conditions. Fault during relay test. Please contact SMA if this fault occurs often or repeatedly. Measurement difference between BFR and SRR: Fac, Uac or Zac. Fault in the acquisition of measurement data. Contact SMA if this fault occurs frequently. Functional fault in one of the two microcontrollers. Please contact SMA if this fault occurs often or repeatedly. A grounding fault exists or one of the thermally monitored varistors on the DC input is defective as a result of overvoltage. Consult trained electrical personnel to correct the fault. You can find Instructions on how to change the varistors in the "Installation manual". The Windy Boy 5000 / 6000 firmware is faulty. Contact SMA if this fault occurs frequently. The mains voltage has exceeded the permissible range ("Bfr" or "Srr" is an internal message that has no meaning for the user). The Uac fault can have the following causes: Mains supply disconnected (circuit breaker or fuse) Broken AC cable or AC cable has a high internal resistance For reasons of safety, the Windy Boy 5000 / 6000 disconnects itself from the mains supply. Check the mains voltage and mains connections on the Windy Boy 5000 / If the mains voltage lies outside the acceptable range because of local conditions, ask the electricity provider if the voltage can be adjusted at the feed-in point or if they agree to changes in the values of the monitored operational limits. If the mains voltage lies within an acceptable range and "Uac-Bfr" or "Uac-Srr" faults are still being displayed, please contact the SMA hotline. Operating instructions WB50_60-11:FE4105 Page 61
62 General information Fault code UpvMax / Vpv-Max Watchdog Zac-Bfr/ Zac-Srr Description Over voltage on DC input Immediately disconnect the DC input of the Windy Boy 5000 / The Windy Boy 5000 / 6000 may otherwise be damaged seriously! Check the configuration of your system and measure the DC voltage before reconnecting the Windy Boy 5000 / 6000 to the DC voltage. Fault in the program code flow monitoring. The mains impedance has exceeded the permissible range ("Bfr or "Srr is an internal message that has no meaning for the user). The Windy Boy 5000 / 6000 disconnects from the mains supply or standalone grid, to avoid potential damage. The impedance is calculated from the mains supply impedance and the impedance of the mains connection cable (AC cable) of the Windy Boy 5000 / Check the mains impedance and mains connections on the Windy Boy 5000 / Use a mains connection cable with an adequate cross section (= low impedance), and observe the advice to this effect in the installation guide in chapter 4.3. If the mains impedance is still too high, then ask the electricity provider if the characteristics of the mains supply at the feed-in point can be altered. Page 62 WB50_60-11:FE4105 Operating instructions
63 General information 10.3 Declaration of conformity (CE) CE Declaration of Conformity for utility interactive inverters Product: Windy Boy Type: WB 3300, WB 3800, WB 5000, WB 6000 We declare that the above specified devices are compliant with the regulations of the European Community, in terms of the design and the version fabricated by SMA. This especially applies for the EMC Regulation defined in 89/336/EWG and the low voltage regulation defined in 73/23/EWG. The devices are compliant with the following standards: EMC: Emission: DIN EN : DIN EN : DIN EN 55022: , Class B Utility Interference: DIN EN : DIN EN : (Draft) Immunity: DIN EN : DIN EN : Safety: DIN EN 50178: Semiconductor-Converter: DIN EN : The above mentioned devices are therefore marked with a CE sign. Niestetal, 20th of June 2005 SMA Technologie AG i.v. Frank Greizer (Head of Development Department Solar Technology) SMA Technologie AG Hannoversche Strasse Niestetal Tel Fax [email protected] WB-G16A-CE-12:BE2905 Operating instructions WB50_60-11:FE4105 Page 63
64 General information 10.4 Import certificate The Windy Boy 5000 / 6000 string inverter is equipped with the "SMA grid guard" independent disconnection device and it is covered by the industrial trade association "SMA grid guard" import certificate. Page 64 WB50_60-11:FE4105 Operating instructions
65 Stand-alone systems 11 Stand-alone systems The Windy Boy 5000 / 6000 is suitable for use in stand-alone systems based on the Sunny Island. The Windy Boy 5000 / 6000 requires extra settings for this to ensure optimum operation and also to achieve deactivation of the standard mains supply monitoring settings. Please obtain all further relevant information from the Sunny Island manuals. Sunny Island 4248 Sunny Boy Windy Boy AC bus or Consumers Generator Public Utility Mini CHP Operating instructions WB50_60-11:FE4105 Page 65
66 Stand-alone systems Page 66 WB50_60-11:FE4105 Operating instructions
67 Contact 12 Contact If you have any questions or technical problems concerning the Windy Boy 5000 / 6000, please contact our service hotline. Please have the following information available when you contact SMA: Inverter type Type of wind turbine and AC/DC converter Type of overvoltage protection Communication Serial number of the Windy Boy 5000 / 6000 Address: SMA Technologie AG Hannoversche Strasse Niestetal Germany Tel.: Fax: [email protected] Operating instructions WB50_60-11:FE4105 Page 67
68 Contact Page 68 WB50_60-11:FE4105 Operating instructions
69
70 SMA Technologie AG Sales SMA Solar Technology Rosendahl Industrievertretungen Adolf-Dembach-Strasse Krefeld Germany Tel Fax SMA Solar Technology China International Metro Center, Building A, City Square No. Jia 3, Shilipu Road, Changyang District Beijing, P.R. China Tel SMA Spain Rosendahl Técnica Energética, S.L. Decages S.A. Balmes, 297, 1er, 2a Barcelona, Spain Freecall +800 SUNNYBOY Freecall SMA America, Inc Loma Rica Drive, Unit C Grass Valley, CA 95945, USA Tel SMA Italy Rosendahl Tecnologie Energetiche S.r.I. Via Lorenzo Valla, Milano, Italy Freecall +800 SUNNYBOY Freecall Innovation in Systems Technology for the Success of Photovoltaics Seite 70 WB :FD2805 Betriebsanleitung
Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK
Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK Installation Guide BTPB-IEN112112 98-0014212 Version 1.2 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Notes on this
YSmart Technology Co.,Ltd
YSmart Technology Co.,Ltd GWV Series Grid Tie Microinverter User Manual The copyright of this user manual belong to YSmart TechnologyCompany Limited. Without the written permission of the copyright holder,
SMA Bluetooth. Content. SMA Bluetooth Wireless Technology in Practice. Further Documents on SMA Bluetooth
Technical Information Wireless Technology in Practice Content This document summarises the main features of Wireless Technology and provides answers to questions from practice. Further Documents on The
alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS
alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS Safety precautions Safety precautions The DSL modem alpha DSL WTM HS complies with the European norm EN60950 safety of information technology
2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams 3000. Sunteams 4000 Sunteams 5000
Photovoltaic Inverter Specification Version 2.06 1500 2000 3000 4000 5000 Kinglong New Energy Technology Co.Ltd. Kinglong New Energy Technology Co.Ltd. specification 1.1. Introduction... 3 1.1.1. Environment...
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
WEB log. Device connection plans
WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20160425* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,
TIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
Photovoltaic Solar Energy Unit EESFB
Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality
Monitor Simply and Securely
Monitor Simply and Securely Solar Monitoring Systems from SMA Solar Monitoring Systems from SMA MONITORING, INFORMING, PRESENTING Securing yield easily for small, large and very large solar power systems
Smile 11 AS-i Emergency stop with safe AS-i input node
Original instructions Smile 11 AS-i Emergency stop with safe AS-i input node SAFETY AT WORK ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand
System Monitoring SMA Safety and Password Concept for Password-protected PV Plants with Bluetooth Wireless Technology
System Monitoring SMA Safety and Password Concept for Password-protected PV Plants with Bluetooth Wireless Technology Technical Description Sicherheit-TEN103010 Version 1.0 EN SMA Solar Technology AG
Performance ratio. Contents. Quality factor for the PV plant
Performance ratio Quality factor for the PV plant Contents The performance ratio is one of the most important variables for evaluating the efficiency of a PV plant. Specifically, the performance ratio
User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.
DONGGUAN SHENGYANG INDUSTRIAL CO., LTD SY WMVC Smart Grid Tie Microinverter User Manual Dongguan Shengyang Industrial Co., Ltd. ADD: No. 1 Shangxin Road, New Village, Xin An Community, Chang An Town, Dongguan
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
Infrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
Ambient Temperature Sensor TEMPSENSOR-AMBIENT
Ambient Temperature Sensor TEMPSENSOR-AMBIENT Installation Guide TempsensorAmb-IEN110610 98-0042210 Version 1.0 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Notes on this Guide...............................
Simple and secure monitoring
Simple and secure monitoring SMA Solar Monitoring Systems SMA Solar Monitoring Systems Monitoring, informing, presenting Easily securing yield for small, large and very large solar power systems Sunday
AC COUPLED HYBRID SYSTEMS AND MINI GRIDS
, Michael; Hermes, Matthias SMA Technologie AG Hannoversche Str. 1-5 34266 Niestetal GERMANY E-mail: [email protected] E-mail: [email protected] 1. INTRODUCTION Distributed supply based on renewable
Antenna Splitter ASA 1. Instruction manual
Antenna Splitter ASA 1 Instruction manual Contents Important safety instructions... 2 The ASA 1 active antenna splitter... 4 Delivery includes... 4 Operating elements... 5 Putting the ASA 1 into operation...
14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5
AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC
MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS
MAKING MODERN LIVING POSSIBLE UniLynx Indoor User Manual ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS Contents Contents 1. Introduction 2 Introduction 2 2. Function Description 3 Definition
alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG
alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG Safety precautions Safety precautions The DSL modem alpha DSL WTM EG complies with the European norm EN60950 safety of information technology
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
WEB log. Device connection plans
WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20151210* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,
Tina 2A/B Adaptor unit
Original instructions Tina 2A/B Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
US Installation Manual Smappee Monitor
US Installation Manual Smappee Monitor Version 1.3 English, US, version 1.3, revision 23, as of October 23, 2014, 2013 Smappee NV. All rights reserved. Specifications are subject to change without notice.
Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20
Documentation for KL2602 and KL2622 Two-channel Relay Output Terminals for 230 V AC / 30 V DC Version: 1.4 Date: 2013-03-20 Table of contents Table of contents 1 Foreword 1 1.1 Notes on the documentation
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
Original instructions Tina 3A/Aps Adaptor unit
Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
Introduction. Page 2 / 9
Installation Manual English, US, version 1.1, as of November 13th, 2015 2015 Smappee NV. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their
Disclaimers. Important Notice
Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,
White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5
White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code June 2015 Revision 1.5 Shalhevet Bar-Asher; SolarEdge Technologies, Inc. Bill Brooks, PE; Brooks Engineering LLC
MITSUBISHI ELECTRIC ANNOUNCES PHOTOVOLTAIC INVERTER FOR EUROPEAN MARKET
FOR IMMEDIATE RELEASE No. 2387 Product & Catalogue Inquiries: Media Contact Naoto Shimada Travis Woodward Nakatsugawa Works Public Relations Department Photovoltaic Power System Business Center Mitsubishi
RIGtalk. Revision 5. Owner s Manual 2012.
RIGtalk Revision 5 Owner s Manual 2012 www.westmountainradio.com 1020 Spring City Drive Waukesha, WI 53186 262-522-6503 [email protected] 2012 West Mountain Radio, All rights reserved. All trademarks
EPM3. Phase Sequence and Motor Rotation Tester. Users Manual
EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR
Multi-Protocol decoder 76 200 with Load regulation
Multi-Protocol decoder 76 2 with Load regulation For locomotives with universal motors on digital layouts operating in the DCC and Motorola data format. Features 76 2 Load regulated multi-protocol decoder
CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008
CAT AVR V2.3 Voltage regulator for generators March 2008 Instruction Manual Warnings WARNING The system should not be installed, operated, serviced or modified except by qualified personnel who understand
Accessories SUNNY REMOTE CONTROL
Accessories SUNNY REMOTE CONTROL Mounting Instructions SRC20-MO-IEN121010 IMEN-SRC20 Version 1.0 EN SMA Solar Technology AG 1 Information on this Document 1 Information on this Document Validity This
KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data
KACO-monitoring watchdog insight prolog Integrated monitoring available Monitor up to 32 inverters per prolog Reliable and accurate data Email alarms to maximize uptime Historical, current and production
Sunny Boy SB 700. String Inverter 700 W, grid-tied operation, grid frequency 777,00 50 Hz / 60 Hz auto-detection SB 1100LV
Sunny Boy SB 700 String Inverter 700 W, grid-tied operation, grid frequency 777,00 50 Hz / 60 Hz auto-detection Sunny Display + Radio (for Sunny Beam, incl. 104,00 SB 1100 String Inverter 1000 WNom / 1100
/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.
56 / Accessories for inverters Accessories for inverters / Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards. FRONIUS STRING
GRID TIE INVERTER MANUAL GRID TIE INVERTER SWEA EUROPE FRIENDLY CARE FOR YOUR EXPENSES AND OUR ENVIRONMENT! WWW.SWEA.
GRID TIE INVERTER MANUAL GRID TIE INVERTER STARTER-KIT FOR SMALL urban WindturbineS UP TO MAX 1000 Watt TYPE: UWT-I-250 ST-KIT SWEA EUROPE FRIENDLY CARE FOR YOUR EXPENSES AND OUR ENVIRONMENT! WWW.SWEA.NL
Technical Information POWER PLANT CONTROLLER
Technical Information POWER PLANT CONTROLLER Content The Power Plant Controller offers intelligent and flexible solutions for the control of all PV power plants in the megawatt range. It is suitable for
Owner s Manual 900.4. 4 channel amplifier
Owner s Manual 900.4 4 channel amplifier THANK YOU Limited Warranty: for purchasing RE AUDIO Bluetooth amplifiers BT-900.4. With almost no sacrifice on sound quality, BT-900.4 easily plays the music from
SUNNY BEAM USB Driver Installing the Sunny Beam USB Driver. 1 Sunny Beam USB Driver. Version: 1.4
SUNNY BEAM USB Driver Installing the Sunny Beam USB Driver Version: 1.4 1 Sunny Beam USB Driver The Sunny Beam USB driver is needed to connect a Sunny Beam to a computer. System requirements: The Sunny
19 LED Tube Controller ORDERCODE 41003
19 LED Tube Controller ORDERCODE 41003 Congratulations! You have bought a great, innovative product from Showtec. The Showtec 19 LED Tube Controller brings excitement to any venue. Whether you want simple
ABB central inverters PVS800 100 to 1000 kw
Solar inverters ABB central inverters PVS800 100 to 1000 kw ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators and
Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
COMPLETE MANUAL. Version: Optic. September 2015 (English), version 1.0. EnergyOT Optic Developed and Manufactured by Genoa Spark, lda Made in Portugal
Version: Optic COMPLETE MANUAL September 2015 (English), version 1.0. EnergyOT Optic Developed and Manufactured by Genoa Spark, lda Made in Portugal Specifications are subject to change without notice.
Digi-Motor Installation Guide
Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support
Installation and safety instructions for AC/DC built-in devices
The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further
LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 [email protected]
Integrations LGAC-KNX V1.0 PROGRAMMING MANUAL Parque Tecnológico de Asturias, Parcela 50, 33428 Llanera Asturias - Spain Tel (+34) 985 118 859 Fax (+34) 984 283 560 [email protected] www.ingeniumsl.com
LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems
Universal Split Systems If there is a fault on any LG Universal unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the fault will
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting
12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.
PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.
PSDC 08128 v.1.2 PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. EN** Edition: 9 from 25.05.2015 Supersedes the edition: 8 from 12.12.2014 the 8x 1A/12V DC power output for powering
Addendum to the Operating Instructions
Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions MOVIMOT with AS-Interface and AC Motor DT/DV Unit Replacement MOVIMOT MM..C -> MM..D with MLK3A
MODEL 2202IQ (1991-MSRP $549.00)
F O R T H E L O V E O F M U S I C F O R T H E L O V E O F M U S I C MODEL 2202IQ (1991-MSRP $549.00) OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION Congratulations on your decision to purchase a LINEAR
Criteria for Selecting a Residual-Current Device
Criteria for Selecting a Residual-Current Device Use of Residual-Current Devices for SUNNY BOY, SUNNY MINI CENTRAL and SUNNY TRIPOWER Content When installing inverters, there are often uncertainties when
Firmware Update with SD Card SUNNY BOY WINDY BOY SUNNY TRIPOWER
Firmware Update with SD Card SUNNY BOY WINDY BOY SUNNY TRIPOWER Technical Description NG_UpdSD-TB-en-32 Version 3.2 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Information on this
EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information
London Electronics Limited Warren Court, Chicksands, Shefford, Bedfordshire SG17 5QB Tel +44(0)1462-850967 Fax +44(0)1462-850968 www.london-electronics.com [email protected] Ethernet to RS232
WSD130 SOLDERING STATION
NOTES S2032ACH 8/98 Rev. 11/01 WSD130 SOLDERING STATION 1. Power Switch 2. Digital Display 3. UP Button 4. DOWN Button 5. Optical Regulator, Right 6. Connection for Soldering Iron, Right 7. Selection Switch
User and Installation Guide
Connect the AC adapter with the amplifier BEFORE plugging the AC adapter into an outlet to avoid spark generation! User and Installation Guide BlueFIDELITYTM Bluetooth Audio Amplifier Model 300 Contents
Operation Manual. Plasma torch height controller. Model: Compact THC Controller 150
Operation Manual Plasma torch height controller. Model: Compact THC Controller 150 Notes on safety WHEN THE DEVICE IS IN OPERATION, VOLTAGE HAZARDOUS TO HEALTH AND HUMAN LIFE IS PRESENT INSIDE THE HOUSING
APPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract.
TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION Abstract This application note describes the four quadrant mode of operation of a linear AC Power
Quick start guide smart.power smart.power smart.power
Quick start guide Intended use: smart.power is a universal charging device for charging (in absence of other charging options) your mobile phone, your TEASI-navigation system or other devices with a 5V
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
About This Guide SolarEdge Configuration Tool Software Guide. About This Guide
About This Guide 3 About This Guide This user guide is intended for Photovoltaic (PV) system owners, installers, technicians, maintainers, administrators and integrators who are authorized to configure
ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw
Solar inverters ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw PV energy, combined with energy storage systems, can help increase self-consumption and energy selfsufficiency*. One of the biggest challenges
Fronius IG Plus. The next generation grid-connected PV inverter
Fronius IG Plus The next generation grid-connected PV inverter Maximum energy harvest cloudy or clear The first complete inverter solution. Reliable. Proven. Smart. An outstanding addition to the family:
Sunny Boy Accessories SMA POWER BALANCER
Sunny Boy Accessories SMA POWER BALANCER Installation Guide SBUS-PowBal-IUS102810 IMUS-SBUS-PBL Version 1.0 US SMA America, LLC Legal Restrictions Copyright 2010 SMA America, LLC. All rights reserved.
SOLAR POWER - THE NEW WAY TO RV!
IMPORTANT! - YOU'RE SOLAR READY SOLAR POWER - THE NEW WAY TO RV! Your RV is PRE-WIRED for SOLAR POWER! Benefits of Solar Zamp Solar Portable Solar Kit Maximize Battery Life Electrical Independence Green,
SOLAR POWER CONDITIONER Service Manual
SOLAR POWER CONDITIONER Service Manual JH-1600E Released in May 2009 Version: V00 TABLE OF CONTS Important Service Safety Precautions 2 Warning.. 3 General Information.. 5 1 System Overview... 5 2 Overview
SUNNY TRIPOWER 5000TL 12000TL
SUNNY TRIPOWER 5000TL 12000TL STP 5000TL-20 / STP 6000TL-20 / STP 7000TL-20 / STP 8000TL-20 / STP 9000TL-20 / STP 10000TL-20 / STP 12000TL-20 NEW available as 10 kva and 12 kva versions Economical Flexible
Single-Phase AC Synchronous Generator
ST Series Single-Phase AC Synchronous Generator Instructions for Operation and Maintenance English to English translation by R.G. Keen, May 2004. ST Series of Single-Phase AC Synchronous Generators Description
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
AC3200 INTELLIGENT BROADBAND AMPLIFIER
Kari Mäki 9.4.2013 1(7) AC3200 INTELLIGENT BROADBAND AMPLIFIER AC3200 is the latest leading-edge addition to AC family with extended frequency and gain ranges and integrated electrical controls in both
Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.
Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com
Powerline 1200 User Manual
User Manual Models PL1200 PLP1200 January 2016 202-11566-01 350 E. Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product.you can visit www.netgear.com/support to register
Kvaser Mini PCI Express User s Guide
Kvaser Mini PCI Express User s Guide Copyright 2013-2014 Kvaser AB, Mölndal, Sweden http://www.kvaser.com Printed Sunday 28 th September, 2014 We believe that the information contained herein was accurate
DALI RC BASIC SO. Control unit Operating instructions
DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness
When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
Romana Brentgens / photon-pictures.com (2)
science & technology inverters test Simple design both inside and out: The results of thermographic imaging were impressive there were only two areas where temperatures were elevated, but they were still
Installation guide H-5500-8554-03-A. HSI hardwired system interface
Installation guide H-5500-8554-03-A HSI hardwired system interface 2008-2011 Renishaw plc. All rights reserved. This document may not be copied or reproduced in whole or in part, or transferred to any
CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual
CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CGWTS-M001A Version 1, Release 1, December 2004 NOTICE
USER MANUAL. Model 6103 3U ForeFront Alarm Card SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007. An ISO-9001 Certified Company
USER MANUAL Model 6103 3U ForeFront Alarm Card An ISO-9001 Certified Company Part# 07M6103 Doc# 123011U Rev. A Revised 7/15/03 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 CONTENTS 1.0
Operation Manual. Model : Compact THC Controller SD. ( Step / Dir PID generator) A new generation height controller of plasma torach
Operation Manual A new generation height controller of plasma torach Model : Compact THC Controller SD ( Step / Dir PID generator) Notes on safety WHEN THE DEVICE IS IN OPERATION, VOLTAGE HAZARDOUS TO
Current Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
Installation and operating instructions. Solar charge controller Solarix MPPT 2010 730927 Z03 1242 730927 Z03 1242
Installation and operating instructions Solar charge controller Solarix MPPT 2010 EN 730927 Z03 1242 730927 Z03 1242 1 Contents 1. About these instructions...3 1.1 Applicability...3 1.2 Users...3 1.3.
MIGRATION HEIGHT-ADJUSTABLE DESKS. Troubleshooting Guide
Troubleshooting Guide Control Box Power Cable Wire Manager Controller Lifting Column Foot Low-Voltage Cable MIGRATION HEIGHT-ADJUSTABLE DESKS HOW THEY WORK Each Lifting Column contains an individual motorized