Compact Operating Instructions
|
|
|
- Steven Poole
- 9 years ago
- Views:
Transcription
1 Drive Technology \ Drive Automation \ System Integration \ Services Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV Edition 11/ / EN
2 SEW-EURODRIVE Driving the world
3 Contents Contents 1 General Information Scope of this documentation Structure of the safety notes Safety Notes General information Target group Designated use Transportation, storage Installation Electrical connection Safe disconnection Operation Type Designations Sample motor nameplate Sample inverter nameplate Unit identification "Mounting close to the motor" design Mechanical Installation MOVIMOT gearmotor Installing the MOVIMOT inverter close to the motor Tightening torques Electrical Installation Installation instructions Connection of MOVIMOT Connection between MOVIMOT and motor when mounted close to the motor Startup Important notes on startup Description of the controls Description of the DIP switches S Description of DIP switches S Startup with binary control Supplementary notes for installation close to the motor Startup with RS-485 Interface/Fieldbus Important notes on startup Startup procedure Operation Operating display Service Status and error display Replacing units Declaration of Conformity Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV 3
4 1 General Information Scope of this documentation MOVIMOT Æ MM..D with AC Motor DT/DV 1 General Information 1.1 Scope of this documentation This documentation contains the general safety notes and selected information regarding MOVIMOT MM..D with AC motor DT/DV. Please note that this documentation does not replace the detailed operating instructions. Read the detailed operating instructions before you start working with MOVIMOT MM..D. Observe the information, instructions and notes in the detailed operating instructions and the "AC Motors DR/DV/DT/DTE/DVE" operating instructions. This is essential for fault-free operation of MOVIMOT MM..D and fulfillment of any rights to claim under guarantee. The enclosed CD or DVD contains PDF files of the additional operating instructions as well as further MOVIMOT MM..D documentation. All SEW-EURODRIVE s technical documentation is available to download in PDF format from the SEW-EURODRIVE website: Structure of the safety notes The safety notes in these operating instructions are structured as follows: Pictogram SIGNAL WORD Type and source of danger. Possible consequence(s) if disregarded. Measure(s) to prevent the danger. Example: DANGER Imminent danger Severe or fatal injuries General danger WARNING Possible dangerous situation Severe or fatal injuries CAUTION Possible dangerous situation Minor injuries Specific danger, e.g. electric shock NOTICE Possible damage to property Damage to the drive system or its environment Pictogram Signal word Meaning Consequences if disregarded INFORMA- TION Useful information or tip. Simplifies the handling of the drive system. 4 Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
5 Safety Notes General information 2 2 Safety Notes The following basic safety notes must be read carefully to prevent injury to persons and damage to property. The operator must ensure that the basic safety notes are read and observed. Make sure that persons responsible for the plant and its operation, as well as persons who work independently on the unit, have read through the operating instructions carefully and understood them. If you are unclear about any of the information in this documentation, please contact SEW-EURODRIVE. 2.1 General information Never install or start up damaged products. Submit a complaint to the shipping company immediately in the event of damage. During operation, MOVIMOT drives can have live, bare and movable or rotating parts as well as hot surfaces, depending on their enclosure. Removing covers without authorization, improper use as well as incorrect installation or operation may result in severe injuries to persons or damage to property. Refer to the documentation for additional information. 2.2 Target group Only qualified electricians are authorized to install, startup or service the units or correct unit faults (observing IEC or CENELEC HD 384 or DIN VDE 0100 and IEC or DIN VDE 0110 as well as national accident prevention guidelines). Qualified personnel in the context of these basic safety notes are persons familiar with installation, assembly, startup and operation of the product who possess the necessary qualifications. Any activities regarding transportation, storage, operation, and disposal must be carried out by persons who have been instructed appropriately. 2.3 Designated use MOVIMOT drives are components intended for installation in electrical systems or machines. In case of installation in machines, startup of MOVIMOT inverters (i.e. start of designated operation) is prohibited until it is determined that the machine meets the requirements stipulated in the EC Directive 2006/42/EC (machine directive). Startup (i.e. the start of designated use) is only permitted under observance of the EMC directive 2004/108/EC. MOVIMOT inverters comply with the regulations of the Low Voltage Directive 2006/95/ EC. The standards given in the declaration of conformity are used for MOVIMOT inverters. You must observe the technical data and information on the connection requirements as provided on the nameplate and in the documentation. Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV 5
6 2 Safety Notes Transportation, storage Safety functions The MOVIMOT inverter may not perform safety functions unless these functions are described and expressly permitted. For safety functions, ensure that the information in the supplied publications is observed. Use only components in safety applications that were explicitly designed and supplied for this purpose by SEW-EURODRIVE Hoist applications When using MOVIMOT inverters in hoist applications, you must observe the special configuration and settings for hoist applications specified in the operating instructions for MOVIMOT. MOVIMOT inverters may not be used as a safety device in hoist applications. 2.4 Transportation, storage You must observe the notes on transportation, storage and proper handling. Comply with the requirements for climatic conditions stated in chapter "Technical Data" of the operating instructions. Tighten installed eyebolts securely. They are designed for the weight of the MOVIMOT drive. Do not attach any additional loads. Use suitable, sufficiently rated handling equipment (e.g. rope guides) if required. 2.5 Installation The units must be installed and cooled according to the regulations and specifications in the corresponding documentation. Protect the MOVIMOT inverters from improper strain. The following applications are prohibited unless the unit is explicitly designed for such use: Use in potentially explosive atmospheres. Use in areas exposed to harmful oils, acids, gases, vapors, dust, radiation, etc. Use in non-stationary applications with strong mechanical oscillation and impact loads, as specified in the documentation 2.6 Electrical connection Observe the applicable national accident prevention guidelines when working on live MOVIMOT drive inverters (e.g. BGV A3). Perform electrical installation according to the pertinent regulations (e.g. cable cross sections, fusing, protective conductor connection). For any additional information, refer to the applicable documentation. For information on EMC-compliant installation such as shielding, grounding, arrangement of filters and routing of lines refer to the documentation. The manufacturer of the system or machine is responsible for maintaining the limits established by EMC legislation. 6 Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
7 Safety Notes Safe disconnection 2 Protective measures and protection devices must comply with the regulations in force (e.g. EN or EN ). A voltage test according to EN :2007 chapter is required for MOVIMOT drives prior to startup to ensure insulation. 2.7 Safe disconnection MOVIMOT inverters meet all requirements for safe disconnection of power and electronic connections in accordance with EN All connected circuits must also satisfy the requirements for safe disconnection. 2.8 Operation Systems with integrated MOVIMOT inverters must be equipped with additional monitoring and protection devices according to the applicable safety guidelines, such as the law governing technical equipment, accident prevention regulations, etc. Additional protective measures might be necessary for applications with increased potential risk. Do not touch live components or power connections immediately after disconnecting the MOVIMOT inverter, the field distributor (if installed) or the bus module (if installed) from the supply voltage because there may still be some charged capacitors. Wait at least for 1 minute after having switched off the supply voltage. As soon as supply voltage is present at the MOVIMOT inverter, the terminal box must be closed, which means that: The MOVIMOT inverter must be screwed on. The terminal box cover of the field distributor (if present) and the bus module (if present) must be bolted down. The connector of the hybrid cable (if installed) must be connected and screwed on. Note: The maintenance switch of the field distributor (if installed) only disconnects the connected MOVIMOT drive or motor from the power supply system. The terminals of the field distributor remain connected to the line voltage even after the maintenance switch is activated. The fact that the status LED and other display elements are no longer illuminated does not indicate that the unit has been disconnected from the supply system and no longer carries any voltage. Mechanical blocking or internal safety functions of the unit can cause a motor standstill. Eliminating the cause of the problem or performing a reset may result in the drive restarting automatically. If, for safety reasons, this is not permitted for the driven machine, disconnect the unit from the supply system before correcting the error. Caution: Danger of burns: The surface temperature of the MOVIMOT drive and of external options, e.g. the heat sink of the braking resistor, can exceed 60 C during operation! Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV 7
8 3 Type Designations Sample motor nameplate 3 Type Designations 3.1 Sample motor nameplate SEW -EURODRIVE Typ Nr. KW 50Hz 60Hz r/min Bremse kg 73 KA77 DT90L4/BMG/MM15/MLU ,5 / 50 HZ 22/1400 V V V230 Ma 665 Nm 20 Nm Bruchsal / Germany IEC 34 B3 0,99 3,50 3,50 54 Kl F 3~ IM cos A A IP Gleichrichter i 64,75 :1 Schmierstoff Made in Germany KA 77 DT 90L4 BMG/MM15/MLU Additional feature: inverter 1) MOVIMOT inverter Optional design motor (brake) Size, number of poles on motor Motor series Gear unit size Gear unit series 1) Nameplate only displays options installed at the factory. 8 Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
9 Type Designations Sample inverter nameplate Sample inverter nameplate Status: A / Typ MM15D Sach.Nr Serien Nr Eingang / Input Ausgang / Output U= 3x V AC U= 3x0V...U Input D Bruchsal f= Hz f= Hz Made in Germany I= 3.5A AC I= 4.0A AC MOVIMOT T= C Antriebsumrichter P-Motor 1.5kW / 2.0HP Drive Inverter P-Motor (S3/25%): 2.2kW / 3.3HP Use 60/75 C copper wire only. Tighten terminals to 13,3in. - ibs.(1.5 Nm) Suitable for use on a circuit capable of delivering not more than 5000ms N2936 CH MM 15 D Design (00 = Standard) Connection type (3 = 3-phase) Supply voltage (50 = AC V) (23 = AC V) Version D Motor power (15 = 1.5 kw) MOVIMOT series 3.3 Unit identification The unit identification [1] on the top of the MOVIMOT inverter provides information about the inverter type [2], inverter part number [3], unit power [4]. [2] [3] [4] [1] Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV 9
10 3 Type Designations "Mounting close to the motor" design 3.4 "Mounting close to the motor" design The following illustration shows an example of the MOVIMOT inverter mounted close to the motor with corresponding nameplate and type designation: MM15D /0/P21A/RO1A/APG4 MM15D /0/P21A/RO1A/APG Plug connector for the connection to the motor Terminal box design Adapter for installation close to the motor 21 = Size 1 22 = Size 2 Connection type 0 = 1 = MOVIMOT inverter 10 Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
11 Mechanical Installation MOVIMOT gearmotor 4 4 Mechanical Installation 4.1 MOVIMOT gearmotor Before you start Only install the MOVIMOT drive if: The entries on the nameplate of the drive match the voltage supply system. The drive is undamaged (no damage caused by transportation or storage). You are certain that the following requirements have been fulfilled: Ambient temperature corresponds to the specifications in chapter "Technical Data" of the operating instructions. Note that the temperature range of the gear unit may also be restricted (see gear unit operating instructions). No oil, acid, gas, vapors, radiation, etc. Installation tolerances The following tables shows the permitted tolerances of the shaft ends and flanges of the MOVIMOT drive. Shaft end Diameter tolerance according to EN ISO j6 with Ø 26 mm ISO k6 with Ø 38 mm up to 48 mm ISO m6 at Ø > 55 mm Center bore in accordance with DIN 332, shape DR.. Flanges Centering shoulder tolerance in accordance with EN ISO j6 with Ø 250 mm ISO h6 with Ø > 300 mm Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
12 4 Mechanical Installation MOVIMOT gearmotor Installing MOVIMOT Observe the following notes for mounting the MOVIMOT drive: Install/mount the MOVIMOT drive only in the mounting position specified on the motor nameplate on a level, vibration-free, and torsionally rigid support structure. Clean the output shafts thoroughly to ensure they are free of anti-corrosion agents (use a commercially available solvent). Do not allow the solvent to penetrate the bearings and shaft seals this could damage the material. Carefully align the MOVIMOT inverter and the motor, to avoid placing any unacceptable strain on the motor shafts (observe permissible overhung load and axial load data!). Do not butt or hammer the shaft end. Use an appropriate cover to prevent objects or fluids from entering motors in vertical mounting positions. Ensure there is sufficient clearance around the unit to allow for adequate cooling. Furthermore, the unit must be positioned in such a way that it does not reuse the air warmed by other devices. Balance components for subsequent mounting on the shaft with a half key (output shafts are balanced with a half key). Existing condensation drain holes must be sealed with plastic plugs. They must not be opened unless needed. Open condensation drain holes are not permitted. If condensation drain holes are open, higher enclosures are no longer possible. STOP The degree of protection specified in the technical data only applies if the MOVIMOT inverter is properly installed. When the MOVIMOT inverter is removed from the connection box, it might be damaged by humidity or dust. Protect the MOVIMOT inverter when it is removed from the connection box Installation in damp locations or in the open Observe the following notes for mounting the MOVIMOT drive in damp areas or in the open: Use suitable cable glands for the supply leads (use reducing adapters if necessary). Coat the threads of cable glands and filler plugs with sealing compound and tighten them well; then coat them again. Seal the cable entries well. Clean the sealing faces of the MOVIMOT inverter well before re-assembly. If the corrosion protection coating is damaged, restore the coating. Check enclosure according to nameplate. 12 Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
13 Mechanical Installation Installing the MOVIMOT inverter close to the motor Installing the MOVIMOT inverter close to the motor The following figure shows the mounting dimensions for installing the MOVIMOT inverter close to the motor: M6 A B M MM03D MM15D MM03D MM07D MM22D MM40D MM11D MM22D A B 140 mm 65 mm 170 mm 65 mm Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV 13
14 4 Mechanical Installation Tightening torques 4.3 Tightening torques MOVIMOT inverter Tighten the screws on the MOVIMOT inverter using 3.0 Nm (27 lb.in) working diagonally across Screw plugs Tighten screw plugs of potentiometer f1 and connection X50 using 2.5 Nm (22 lb.in) Cable glands It is essential to observe the manufacturer's specifications for the cable glands. 14 Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
15 Mechanical Installation Tightening torques Screw plugs for cable entries Tighten screw plugs with 2.5 Nm (22 lb.in) Tightening torques for terminals Use the following tightening torques for terminals during installation: [1] [1] Nm (4 6 lb.in) [2] Nm (4 6 lb.in) [3] Nm (7 10 lb.in) [4] Nm (11 14 lb.in) [5] Nm (18 21 lb.in) [2] [3] [4] [5] Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV 15
16 5 Electrical Installation Installation instructions 5 Electrical Installation 5.1 Installation instructions Connecting supply system leads The rated voltage and frequency of the MOVIMOT inverter must correspond to the data for the power supply system. Cable cross section: according to input current I line for rated power (see chapter "Technical Data" in the operating instructions). Permitted cable cross section of MOVIMOT terminals (does not apply to field distributors): Single-wire conductor (bare wire) Field wiring power terminals 1.0 mm mm 2 (2 x 4.0 mm 2 ) AWG17 AWG10 (2 x AWG10) Flexible conductor (bare litz wire) Control terminals Conductor with Conductor end sleeve without insulating shrouds Conductor with Conductor end sleeve with insulating shrouds 0.5 mm mm mm mm 2 AWG20 AWG17 AWG20 AWG19 Only connect single-wire conductors or flexible conductors with or without conductor end sleeve (DIN part 1, material E-CU) Permitted length of the conductor end sleeve: At least 8 mm Use conductor end sleeves without insulating shrouds (DIN part 1, material E- CU). Install line fuses at the beginning of the power supply cable behind supply bus junction (see the section "Connection of MOVIMOT basic unit"). Use only D, D0 or NH melting fuses or circuit breakers for F11/F12/F13. Select the fuse size according to the cable cross section. SEW recommends using earth-leakage monitors with pulse code measuring in voltage supply systems with a non-earthed star point (IT systems). Using such devices prevents the earth-leakage monitor mis-tripping due to the ground capacitance of the inverter. 16 Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
17 Electrical Installation Installation instructions Earth-leakage circuit breakers Do not use a conventional earth-leakage circuit breaker as a protective device. Universal current-sensitive earth leakage circuit-breakers (tripping current 300 ma) are permitted as a protective device. During normal operation of MOVIMOT inverter, earth-leakage currents of > 3.5 ma can occur. SEW-EURODRIVE recommends that you do not use earth-leakage circuit breakers. However, if an earth-leakage circuit breaker is stipulated for direct or indirect protection against contact, observe the following note in accordance with EN : WARNING Wrong type of earth-leakage circuit breaker installed. Severe or fatal injuries. MOVIMOT can cause direct current in the protective earth. In cases where an earthleakage circuit breaker is used for protection against direct or indirect contact, only install a type B earth-leakage circuit breaker on the power supply end of the MOVIMOT inverter Input contactor Only use a contactor of utilization category AC3 (EN ) as an input contactor. NOTICE Do not use the K11 input contactor (see wiring diagram (page 20)) for jog mode, but only for switching the inverter on and off. For jog mode, use the the commands "CW / Stop" or "CCW / Stop". Observe a minimum switch-off time of 2 s for the supply system contactor K EMC-compliant installation WARNING This drive system is not designed for operation on a public low voltage supply system that supplies residential areas. With respect to the EMC regulation, frequency inverters cannot be operated as standalone units. Regarding EMC, they can only be evaluated when they are integrated in a drive system. Conformity is declared for a described, CE-typical drive system. The operating instructions contain further information. INFORMATION This is a product with restricted availability in accordance with IEC It may cause EMC interference. In this case, it is recommended for the operator to carry out suitable measures. For detailed information on EMC compliant installation, refer to the publication "Electromagnetic Compatibility in Drive Engineering" from SEW-EURODRIVE. Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV 17
18 5 Electrical Installation Installation instructions Notes on PE connection DANGER Incorrect connection of PE. Death, severe injuries or damage to property from electric shock. The permitted tightening torque for the screw fitting is Nm (18-21 lb.in). Observe the following notes regarding PE connection. Prohibited assembly sequence Recommendation: Assembly with forked cable lug Permitted for all cross sections M5 Assembly with thick solid wire Permitted for cross sections up to max. 2.5 mm 2 M5 2.5 mm² [1] [1] Forked cable lug suitable for M5 PE screws Earth-leakage currents 3.5 ma may occur during normal operation. To meet the requirements of EN observe the following note: Route a second PE conductor with the cross section of the supply system lead in parallel to the protective earth via separate terminals or use a copper protective earth conductor with a cross section of 10 mm Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
19 Electrical Installation Installation instructions Installation altitude above 1000 m above sea level MOVIMOT drives with line voltages of 200 to 240 V or 380 to 500 V, can be used in altitudes of 1000 m and up to a maximum of 4000 m above sea level under the following conditions. 1) The rated continuous power is reduced based on the reduced cooling above 1000 m (see "Technical Data" chapter in the operating instructions). Above 2000 m above sea level, the air and creeping distances are only sufficient for overvoltage class 2. If the installation requires overvoltage class 3, you will have to install additional external overvoltage protection to limit overvoltage peaks to 2.5 kv phase-to-phase and phase-to-ground. If safe electrical disconnection is required, it must be implemented outside the device at altitudes of 2000 msl (safe electrical disconnection in accordance with EN ). In installation altitudes between 2000 m to 4000 msl, the permitted rated power supply voltages are reduced as follows: By 6 V per 100 m for MM..D By 3 V per 100 m for MM..D Connecting 24 V supply Power the MOVIMOT inverter either via an external 24 V supply or the MLU..A or MLG..A options Binary control Connect the required control leads. Use shielded cables as control cables and route them separately from supply system cables UL-compliant installation Use only copper cables for temperature range 60/75 C as connection lead. The permitted tightening torques for MOVIMOT power terminals are: 1.5 Nm (13 lb.in). The permitted supply system voltage is 500 V (400/500 V inverter) or 240 V (230 V inverter). Information about the max. permitted short-circuit currents of the supply system and the fuse is listed on the nameplate of the MOVIMOT inverter. INFORMATION Only use certified units with a limited output voltage (V max = DC 30 V) and limited power (P 100 VA) as an external DC 24 V voltage source. The UL certification only applies to the operation on voltage supply systems with voltages to ground of max. 300 V. The UL-certification does not apply to the operation on voltage supply systems with a non-grounded star point (IT systems). 1) The maximum altitude is limited by creeping distances and flameproof components, such as electrolytic capacitors. Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV 19
20 RS Electrical Installation Connection of MOVIMOT 5.2 Connection of MOVIMOT L1 L2 L3 PE F11/F12/F13 Functions of the CW/Stop + CCW/Stop terminals for binary control: 24V R L 24V R L K11 Direction of rotation CW active Direction of rotation CCW active L1 L2 L3 MOVIMOT Functions of terminals f1/f2: 24V R L f1/f2 24V R L f1/f2 Setpoint f1 active Setpoint f2 active M 3~ BMG Functions of the CW/Stop + CCW/Stop terminals for control via RS-485 interface / fieldbus: 24V R L Both directions of rotation are enabled [1] [2] [3] [4] [5] RD WH BU K1 24V R L Only CW direction is enabled Pre-selected setpoints for CCW rotation result in standstill of drive BW [6] 24V + = - R L f1/f2 K1a K1b RS- RS+ 24 V DC V 24V R L R L Only CCW operation is enabled Setpoint specifications for CW rotation result in standstill of drive Drive is inhibited or is being brought to a stop [1] DC 24 V supply (external or MLU..A/MLG..A options) [2] CW / stop [3] CCW / stop [4] Setpoint changeover f1/f2 [5] Ready signal (contact closed = ready for operation) [6] BW.. braking resistor (only for MOVIMOT drives without mechanical brake) 20 Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
21 Electrical Installation Connection between MOVIMOT and motor when mounted close to the Connection between MOVIMOT and motor when mounted close to the motor If the MOVIMOT inverter is mounted close to the motor, the connection to the motor is realized with a pre-fabricated cable (hybrid cable). Use only hybrid cables from SEW-EURODRIVE to connect the MOVIMOT inverter with the motor. The following designs are possible on the MOVIMOT side: A: MM../P2.A/RO.A/APG4 B: MM../P2.A/RE.A/ALA4 The APG4 design results in the following connection options to the motor, depending upon the hybrid cable used: Design A1 A2 A3 A4 MOVIMOT APG4 APG4 APG4 APG4 Motor Cable gland/terminals ASB4 APG4 IS Hybrid cables X A1 A2 APG4 APG4 [1] ASB4 A3 A4 APG4 APG4 APG4 ISU4 [1] Connection via terminals Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV 21
22 5 Electrical Installation Connection between MOVIMOT and motor when mounted close to the The APG4 design results in the following connection options to the motor, dependent upon the hybrid cable used: Type B1 B2 MOVIMOT ALA4 ALA4 Motor Cable gland/terminals ASB4 Hybrid cables B1 ALA4 B2 ALA4 [1] ASB4 [1] Connection via terminals Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
23 Electrical Installation Connection between MOVIMOT and motor when mounted close to the Hybrid cable connection The following tables shows the conductor assignment in hybrid cables with part number and and the corresponding motor terminals of the DT/DV motor: Motor terminal of DT/DV motors U1 V1 W1 4a 3a 5a 1a 2a PE connection Wire color/hybrid cable designation Black/U1 Black/V1 Black/W1 Red/13 White/14 Blue/15 Black/1 Black/2 Green/yellow + shield end (internal shield) The following figure shows the connection of the hybrid cable to the terminal box of the DT/DV motor. PE GNYE U1 V1 W1 BK/W1 BK/V1 BK/U1 1 a 2 a 3 a 4 a 5 a BU RD WH BK/2 BK/1 W2 U2 V2 U1 V1 W1 W2 U2 V2 U1 V1 W Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV 23
24 6 I 0 Startup Important notes on startup 6 Startup 6.1 Important notes on startup DANGER Before removing / fitting the MOVIMOT inverter, you must disconnect it from the supply system. Dangerous voltages may still be present for up to one minute after disconnection from the power supply. Severe or fatal injuries from electric shock. Disconnect the MOVIMOT drive from the power supply using an appropriate external disconnecting device and secure it against unintentional reconnection to the voltage supply. Then wait at least for 1 minute. WARNING The surfaces of MOVIMOT and external options, e.g. braking resistor (especially the heat sink), can become very hot during operation. Danger of burns. Do not touch the MOVIMOT drive and external options until they have cooled down sufficiently. INFORMATION Remove paint protection cap from the status LED before startup. Remove paint protection film from the nameplates before startup. Check that all protective covers are installed correctly. Observe a minimum switch-off time of 2 seconds for the mains contactor K Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
25 Startup Description of the controls I Description of the controls Setpoint potentiometer f1 Depending on the operating mode of the MOVIMOT inverter, the potentiometer f1 has different functions: Binary control: Setting setpoint f1 (selected via terminal f1/f2 = "0") Control via RS-485: Setting maximum frequency f max f[hz] 100 f [1] [1] Potentiometer setting NOTICE The enclosure specified in section Technical Data only applies if the screw plugs of the setpoint potentiometer and the X50 diagnostic interface are installed correctly. Missing or incorrectly installed screw plugs can cause damage to the MOVIMOT inverter. Make sure the screw plug of the setpoint potentiometer f1 has a seal and screw it in Switch f2 Depending on the operating mode of the MOVIMOT inverter, switch f2 has different functions: Binary control: Setting setpoint f2 (selected via terminal f1/f2 = "1") Control via RS-485: Setting minimum frequency f min Switch f2 Detent setting Setpoint f2 [Hz] Minimum frequency [Hz] Switch t1 3 Use switch t1 to set the acceleration of the MOVIMOT drive. The ramp times are based on a setpoint step change of 1500 rpm (50 Hz) Switch t1 Detent setting Ramp time t1 [s] 0,1 0,2 0,3 0,5 0, Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV 25
26 6 I 0 Startup Description of the controls DIP switches S1 and S DIP switch S1: S Meaning Binary encoding RS-485 unit address Motor protection Motor Power rating PWM Frequency No-load damping ON Off Motor one size smaller Variable (16, 8, 4 khz) On OFF On DIP switch S2: Motor adjusted 4 khz Off S Meaning Motor type Release brake without enable Operating mode Speed monitoring Binary encoding additional functions ON SEW DZ motor 1) On V/f On OFF IEC motor Off VFC Off ) available only in Brazil NOTICE Set the DIP switches using suitable tools, e.g. a flat tip screwdriver with a blade width 3mm. The force used for setting the DIP switches must not exceed 5 N. Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
27 Startup Description of the DIP switches S1 I Description of the DIP switches S DIP switches S1/1 S1/4 Selecting the RS-485 address of MOVIMOT via binary coding Decimal Address S1/1 X X X X X X X X S1/2 X X X X X X X X S1/3 X X X X X X X X S1/4 X X X X X X X X X = ON = OFF Set the following addresses depending on how the MOVIMOT inverter is controlled: Control RS-485 address Binary control 0 Via keypad (MLG..A, MBG..A) 1 Via fieldbus interface (MF..) 1 Via MOVIFIT MC (MTM..) 1 Via intelligent fieldbus interface (MQ..) 1 to 15 Via RS-485 master 1 to DIP switch S1/5 Motor protection switched on/off When MOVIMOT is installed close to the motor, the motor protection function must be deactivated. To ensure that the motor is protected all the same, a TH (bimetallic thermostat) must be installed. The TH opens the sensor circuit when the rated response temperature is reached (see field distributor manual). Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
28 6 I 0 Startup Description of the DIP switches S DIP switch S1/6 Lower motor power rating When activated, this DIP switch enables MOVIMOT to be assigned to a motor with a lower power rating. The rated unit power is not affected. When a motor with a lower power rating is used, the overload capacity of the drive can be increased because, from the perspective of the motor, MOVIMOT is one power rating too big. A higher current can be provided briefly, leading to higher torque ratings. The aim of this switch S1/6 is to achieve short-term utilization of the motor's peak torque. The unit's current limit remains the same regardless of the switch setting. The motor protection function is adjusted depending on the switch setting. Stall protection for the motor is not possible in this operating mode (S1/6 = "ON"). MOVIMOT inverter MM..D Assigned motor 230 / 400 V, 50 Hz 266 / 460 V, 60 Hz S1/6 = OFF S1/6 = ON V MM03D DT71D4 DR63L4 1) DR63L4 1) MM05D DT80K4 DT71D4 DT71D4 DFR63L4 1) MM07D DT80N4 DT80K4 DT80K4 DT71D4 MM11D DT90S4 DT80N4 DT80N4 DT80K4 MM15D DT90L4 DT90S4 DT90S4 DT80N4 MM22D DV100M4 DT90L4 DT90L4 DT90S4 MM30D DV100L4 DV100M4 DV100M4 DT90L4 MM40D DV100L4 DV100L4 DV100M4 MOVIMOT inverter MM..D Assigned motor 230 / 460 V, 60 Hz / S1/6 = OFF S1/6 = ON V MM03D DT71D4 DR63L4 1) MM05D DT80K4 DT71D4 MM07D DT80N4 DT80K4 MM11D DT90S4 DT80N4 MM15D DT90L4 DT90S4 MM22D DV100M4 DT90L4 1) Only possible with installation close to the motor Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
29 Startup Description of DIP switches S2 I DIP switch S1/7 Setting the maximum PWM- frequency When DIP switch S1/7 is set to "OFF", the MOVIMOT unit operates with 4 khz PWM frequency. When DIP switch S1/7 is set to "ON", the MOVIMOT unit operates with a 16 khz PWM frequency (low noise) and switches back in steps to lower switching frequencies depending on the heat sink temperature and the inverter load DIP switch S1/8 No load vibration damping (S1/8 = "ON") When setting DIP switch S1/8, this function reduces resonance during no-load operation. 6.4 Description of DIP switches S DIP switch S2/1 Motor type For IEC and NEMA motors, DIP switch S2/1 must always be set to "OFF". For DZ motors with nominal voltages of 220/380 V, 60 Hz (only available in Brazil), the DIP switch must always be set to "ON" DIP switch S2/2 Brake release without enable When switch S2/2 is set to "ON", it is possible to release the brake even if there is no drive enable. This function is not available in hoist operation. Binary control functions In binary control, the brake can be released by setting the signal at terminal f1/f2 subject to the following preconditions: Terminal status Enable status Fault status Brake function R L f1/f2 "1" "0" "1" "0" "1" "0" "0" "1" "0" "1" "1" "0" "0" Unit enabled No unit fault "1" Unit enabled No unit fault "0" Unit not enabled "1" "1" "1" Unit not enabled "0" "0" "1" Unit not enabled All states possible Unit not enabled No unit error No unit error No unit error Unit fault Brake is controlled by MOVIMOT, setpoint f1 Brake is controlled by MOVIMOT, Setpoint f2 Brake applied Brake applied Brake is released for manual movement Brake applied Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
30 6 I 0 Startup Description of DIP switches S2 RS-485 control functions In RS-485 control, the brake is released via the control word: Master PO PO1 PO2 PO3 DO MOVIMOT PI1 PI2 PI3 DI PI PO = Process output data PI = Process input data PO1 = Control word PI1 = Status word 1 PO2 = Speed [%] PI2 = Output current PO3 = Ramp PI3 = Status word 2 DO = Digital outputs DI = Digital inputs By setting bit 8 in the control word, the brake can be released if the following conditions are met: Basic control block Control word not assigned 1) Bit "9" Bit "8" Not assign ed 1 "1" = Reset Not assigned 1) "1 1 0" = Enable otherwise stop Virtual terminals for releasing the brake without drive enable Virtual terminal for applying brake and inhibiting output stage "Stop" control command 1) Recommendation for all bits that are not assigned = "0" Enable status Unit enabled Unit enabled Unit not enabled Unit not enabled Unit not enabled Error status Status of bit 8 in control word No unit error / no communication timeout No unit error / no communication timeout No unit error / no communication timeout No unit error / no communication timeout Unit error / communication timeout Brake function "0" Brake is controlled by MOVIMOT "1" Brake is controlled by MOVIMOT "0" Brake applied "1" Brake is released for manual movement "1" or "0" Brake applied Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
31 Startup Description of DIP switches S2 I 0 6 Setpoint selection for binary control Setpoint selection in binary control depending on the state of terminal f1/f2: Enable status Terminal f1/f2 Active setpoint Unit enabled Terminal f1/f2 = "0" Setpoint potentiometer f1 active Unit enabled Terminal f1/f2 = "1" Setpoint potentiometer f2 active Behavior if unit not ready LED display If the unit is not ready, the brake is always applied irrespective of the setting of terminal f1/f2 or bit 8 in the control word. The status LED flashes periodically at a fast rate (t on : t off = 100 ms : 300 ms) if the brake has been released for manual movement. This applies both for binary control and for control via RS DIP switch S2/3 Operating mode DIP switch S2/3 = "OFF": VFC operation for 4-pole motors DIP switch S2/3 = "ON": V/f operation reserved for special cases DIP switch S2/4 Speed monitoring Speed monitoring (S2/4 = "ON") protects the drive when it is blocked. If the drive is operated at the current limit for longer than 1 second when speed monitoring is active (S2/4 = "ON"), the MOVIMOT inverter trips the speed monitoring. The status LED of the MOVIMOT inverter signalizes the error by slowly flashing red (t on : t off = 600 ms : 600 ms, fault code 08). This error only occurs when the current limit has been reached for the duration of the deceleration time DIP switches S2/5 S2/8 Additional functions The binary coding of the DIP switches S2/5 - S2/8 allows for the activation of additional functions. Proceed as follows to activate possible additional functions: Decimal Value S2/5 X X X X X X X X S2/6 X X X X X X X X S2/7 X X X X X X X X S2/8 X X X X X X X X X = ON = OFF You find an overview and a description of the additional functions in the detailed operating instructions. Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
32 6 I 0 Startup Startup with binary control 6.5 Startup with binary control DANGER When working on the unit, dangerous voltage levels may still be present up to one minute after the mains is disconnected. Severe or fatal injuries from electric shock. Disconnect the MOVIMOT drive from the power supply using an appropriate external disconnecting device and secure it against unintentional reconnection to the voltage supply. Then wait at least for 1 minute. 1. Check the connection of the MOVIMOT inverter. See section "Electrical Installation". 2. Make sure that the DIP switches S1/1 S1/4 are set to "OFF" (address = 0). This means MOVIMOT is controlled binary via terminals. ON ON Set the first speed at the setpoint potentiometer f1 (active when terminals f1/f2 = "0") (factory setting: about 1500 rpm (50 Hz). f[hz] 100 f [1] [1] Potentiometer setting 4. Make sure the screw plug of the setpoint potentiometer f1 has a seal and screw it in. NOTICE The enclosure specified in the Technical Data chapter only applies if the screw plugs of the setpoint potentiometer and the X50 diagnostic interface are installed correctly. A missing or incorrectly installed screw plug can cause damage to the MOVIMOT inverter. Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
33 Startup Startup with binary control I Set the 2nd speed at switch f2 (active when terminal f1/f2 = "1") Switch f2 Detent setting Setpoint f2 [Hz] INFORMATION The first speed can be changed infinitely variable during operation using the setpoint potentiometer f1, which is accessible from the outside. Speeds f1 and f2 can be set independently of each other Set the ramp time at the switch t1. The ramp times are based on a setpoint step change of 1500 rpm (50 Hz) Switch t1 Detent setting Ramp time t1 [s] Place the MOVIMOT inverter onto the terminal box and screw it on. 8. Switch on the DC 24 V and the supply system voltage Inverter behavior depending on terminal level Inverter behavior Power supply 24V f1/f2 CW/stop CCW/ stop Status LED Inverter off 0 0 x x x Off Inverter off 1 0 x x x Off Stop, no supply system 0 1 x x x Flashing yellow Stop 1 1 x 0 0 Yellow CW operation Green with f1 CCW operation Green with f1 CW operation Green with f2 CCW operation Green with f2 Stop 1 1 x 1 1 Yellow Key 0 = No voltage 1 = Voltage x = Any Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
34 6 I 0 Startup Supplementary notes for installation close to the motor 6.6 Supplementary notes for installation close to the motor Checking the connection type of the connected motor Use the following figure to check that the selected connection type is identical for the MOVIMOT and the connected motor. W2 U2 V2 U1 V1 W1 W2 U2 V2 U1 V1 W Important: For brake motors: Do not install brake rectifiers inside the terminal box of the motor! Motor protection and direction of rotation enable The connected motor must be equipped with a TH. For control via RS-485, the TH must be wired as follows: A MOVIMOT B MOVIMOT C MOVIMOT 24V L R 24V L R 24V L R TH TH TH [A] Both directions of rotation are enabled [B] Only CCW operation is enabled C] Only CW operation is enabled For control via binary signals, SEW-EURODRIVE recommends that you connect the TH in series with the "Ready signal" relay (see the following illustration). The ready signal must be monitored by an external controller. As soon as the ready signal is no longer applied, the drive must be switched off (terminals R and L = "0"). MOVIMOT 24V L R K1a K1b TH SPS Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
35 X1: 13 X1: 14 RS-485 X1: 15 Startup Supplementary notes for installation close to the motor I DIP switch When the MOVIMOT inverter is installed close to the motor, the DIP switch S1/5 must be changed from the factory setting to "ON": S Meaning RS-485 unit address Motor protection ON Off 6 Motor power rating Motor one size smaller 7 PWM Frequency Variable (16, 8, 4 khz) 8 No-load damping OFF On Adjusted 4 khz Off On Braking resistor For motors without brake, a braking resistor must be connected to MOVIMOT (see figure to the right). For brakemotors without BGM option, no braking resistor may be connected to the MOVIMOT. BW1 / BW For brakemotors with BGM option and external braking resistor, the external braking resistor and the brake must be connected as follows. L1 L2 L3 PE F11/F12/F13 K11 BGM [1] U IN U E + _ ~ RD BU BK BK M 3~ L3 MOVIMOT RD WH BU 24V K1 R L f1/f2 K1a K1b RS- RS+ ~ BMG [3] V L1 L2 [4] [5][6] [7] [2] + = Mounting the MOVIMOT inverter in the field distributor Follow the instructions in the corresponding fieldbus manuals when mounting the MOVIMOT inverter close to the motor in the field distributor. Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
36 7 I 0 Startup with RS-485 Interface/Fieldbus Important notes on startup 7 Startup with RS-485 Interface/Fieldbus 7.1 Important notes on startup DANGER Before removing / fitting the MOVIMOT inverter, you must disconnect it from the supply system. Dangerous voltages may still be present for up to one minute after disconnection from the power supply. Severe or fatal injuries from electric shock. Disconnect the MOVIMOT drive from the power supply using an appropriate external disconnecting device and secure it against unintentional reconnection to the voltage supply. Then wait at least for 1 minute. WARNING The surfaces of MOVIMOT and external options, e.g. braking resistor (especially the heat sink), can become very hot during operation. Danger of burns. Do not touch the MOVIMOT drive and external options until they have cooled down sufficiently. INFORMATION Remove paint protection cap from the status LED before startup. Remove paint protection film from the nameplates before startup. Check that all protective covers are installed correctly. Observe a minimum switch-off time of 2 seconds for the mains contactor K Startup procedure 1. Check the connection of the MOVIMOT inverter. See chapter "Electrical Installation". 2. Set the correct RS-485 address on DIP switches S1/1 S1/4. In conjunction with SEW fieldbus interfaces (MF.. / MQ..) or with MOVIFIT, always set address "1". Decimal address S1/1 X X X X X X X X S1/2 X X X X X X X X S1/3 X X X X X X X X S1/4 X X X X X X X X X = ON = OFF Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
37 Startup with RS-485 Interface/Fieldbus Startup procedure I Set minimum frequency f min with switch f Switch f2 Detent setting Minimum frequency f min [Hz] If the ramp is not specified via fieldbus (operation with 2 PD), set the ramp time at switch t1. The ramp times are based on a setpoint step change of 1500 rpm (50 Hz). Switch t1 Detent setting Ramp time t1 [s] Check to see if requested direction of rotation has been enabled. CW/stop CCW/stop Meaning Activated Activated Both directions of rotation are enabled 24V R L Activated Not activated Only CW operation enabled Pre-selected setpoints for CCW rotation result in standstill of drive 24V R L Not activated Activated Only CCW operation enabled Pre-selected setpoints for CW rotation result in standstill of drive 24V R L Not activated Not activated Unit is inhibited or drive brought to a stop 24V R L 6. Place the MOVIMOT inverter onto the terminal box and screw it on. Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
38 7 I 0 Startup with RS-485 Interface/Fieldbus Startup procedure 7. Set the required maximum speed using setpoint potentiometer f1. f[hz] 100 f [1] [1] Potentiometer setting 8. Make sure the screw plug of the setpoint potentiometer f1 has a seal and screw it in. NOTICE The enclosure specified in the Technical Data chapter only applies if the screw plugs of the setpoint potentiometer and the X50 diagnostic interface are installed correctly. A missing or incorrectly installed screw plug can cause damage to the MOVIMOT inverter. 9. Switch on the DC 24 V control voltage / supply system voltage. INFORMATION For information on the function in conjunction with RS-485 master, refer to the operating instructions. For further information on the function in connection with fieldbus interfaces, refer to the relevant fieldbus manuals. Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
39 Operation Operating display I Operation 8.1 Operating display The status LED is located on the top of the MOVIMOT inverter (see following figure). [1] [1] MOVIMOT status LED Meaning of the status LED states The three-color status LED indicates the operating and error states of the MOVIMOT inverter. LED color LED status Operating state Description Off Not ready No 24 V power supply Yellow Yellow Yellow Green /yellow Flashes steadily Not ready Self-test phase active or 24 V power supply present but supply voltage not OK Flashing evenly, fast Steady light Flashing with alternating colors Ready Ready, but unit inhibited Ready, but timeout Brake release without drive enable active (only with S2/2 = "ON") 24 V power supply and supply voltage OK, but no enable signal If drive does not run when enable signal is present - check startup! Faulty communication with cyclical data exchange Green Steady light Unit enabled Motor in operation Green Flashing evenly, Current limit Drive operating at current limit fast active Red Steady light Not ready Check the 24 V supply. Make sure that there is a smoothed DC voltage with low ripple (residual ripple max. 13%) present Status LED flash codes Flashing steadily: Flashing evenly, fast: Flashing with alternating colors: LED 600 ms on, 600 ms off LED 100 ms on, 300 ms off LED 600 ms green, 600 ms yellow For a description of error states, refer to section "Status and error display" (page 42). Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
40 9 I 0 Service Status and error display 9 Service 9.1 Status and error display Status LED The status LED is located on the top of the MOVIMOT inverter. Meaning of the status LED The three-color status LED indicates the operating and error states of the MOVIMOT inverter. LED LED status Error code Description color Off Not ready No 24 V power supply Yellow Yellow Yellow Green /yellow Flashes steadily Not ready Self-test phase active or 24 V power supply present but supply voltage not OK Flashing evenly, fast Steady light Flashing with alternating colors Ready Ready, but unit inhibited Ready, but timeout The error codes are described on the next page. Releasing the brake active without drive enable (only with S2/2 = ON ) 24 V power supply and supply voltage OK, but no enable signal If drive does not run when enable signal is present - check startup! Faulty communication with cyclical data exchange Green Steady light Unit enabled Motor in operation Green Flashing evenly, Current limit Drive operating at current limit fast active Red Steady light Not ready Check the 24 V supply. Make sure that there is a smoothed DC voltage with low ripple (residual ripple max. 13%) present Red 2x flashing, break Error 07 DC link voltage too high Red Flashing slowly Error 08 Speed monitoring error (only with S2/4 = "ON") or additional function 13 is active Error 90 Incorrect motor/inverter assignment Errors 17-24, 37 CPU error Error 25, 94 EEPROM error Red 3x flashing, break Error 01 Overcurrent in output stage Error 11 Overtemperature in output stage Red 4x flashing, break Error 84 Overload in motor Red 5x flashing, break Error 89 Overtemperature in brake Assignment of motor to frequency inverter incorrect Red 6x flashing, break Error 06 Mains phase failure Error 81 Start condition 1) Error 82 Output phases interrupted 1) 1) Only in hoist applications Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
41 Service Status and error display Error list Error Communication timeout (motor stops, without error code) DC link voltage too low, supply system off was detected (motor stops, without error code) Error code 01 Overcurrent in output stage Error code 06 Phase failure (The error can only be detected when the drive is at load) Error code 07 DC link voltage too high Error code 08 Speed monitoring Error code 11 Thermal overload of the output stage or internal unit error Error codes 17 to 24, 37 CPU error Error code 25 EEPROM error Cause/solution Missing connection RS+, RS- between MOVIMOT and RS-485 master. Check and establish connection, especially earth. EMC influence. Check shielding of data lines and improve, if necessary. Incorrect type (cyclical) in acyclical data transfer, protocol time between the individual message is longer than 1 s (timeout interval). Check the number of MOVIMOT units connected to the master (a maximum of 8 MOVIMOT units can be connected as slaves for cyclic communication). Reduce message cycle or select message type "acyclic". Check supply system leads, supply voltage and 24 V electronics supply voltage for interruption. Check the value of the 24 V electronics supply voltage (permitted voltage range 24V ± 25 %, EN residual ripple max. 13 %) In case of cyclical communication, the motor restarts automatically as soon as the voltage reaches normal values. Short circuit on inverter output. Check the connection between the inverter output and the motor as well as the motor winding for short circuits. Reset the fault by switching off the DC 24 V supply voltage or resetting the error. Check the supply system cable for phase failure. Reset the fault by switching off the DC 24 V supply voltage or resetting the error. Ramp time too short Increase ramp time. Faulty connection between brake coil/braking resistor Check the connection between braking resistor and brake coil. Correct, if necessary. Incorrect internal resistance of brake coil/braking resistor Check internal resistance of brake coil/braking resistor (see "Technical Data" chapter in the operating instructions). Thermal overload in braking resistor Wrong size of braking resistor selected. Invalid voltage range of the supply input voltage Check supply input voltage for valid voltage range Reset the error by switching off the DC 24 V supply voltage or resetting the error. Speed monitoring has triggered, load on the drive is too high Reduce the load on the drive Reset the error by switching off the DC 24 V supply voltage or resetting the error. Clean the heat sink Lower ambient temperature Prevent heat build-up Reduce the load on the drive Reset the error by switching off the DC 24 V supply voltage or resetting the error. Reset the error by switching off the 24 V power supply or via error reset. Consult the SEW Service if the error reoccurs. Error while accessing EEPROM Reset the error by switching off the 24 V power supply or via error reset. Consult the SEW Service if the error reoccurs. Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
42 9 Service Status and error display Error Error code 43 communication timeout Error code 81 Start condition error Error code 82 Output open error Error code 84 Thermal overload of motor Error code 89 Thermal overload of brake coil or brake coil defective, brake coil connected incorrectly Error code 94 EEPROM checksum error Cause/solution Communication timeout during cyclical communication via RS-485 If this error occurs, the drive is decelerated and stopped along the set ramp. Check/establish communication link between RS-485 master and MOVIMOT. Check the number of slaves connected to the RS-485 master. If the timeout interval of the MOVIMOT inverter is set to 1 s, you can connect a maximum of 8 MOVIMOT inverters (slaves) to the RS-485 master for cyclical communication. Note: The drive is enabled again after communication has been re-established. The motor could not be supplied with the correct amount of current during the premagnetizing time. Rated motor power too small in relation to rated inverter power Motor cable cross section too small Check connection between MOVIMOT inverter and motor. 2 or all output phases interrupted Rated motor power too small in relation to rated inverter power Check connection between MOVIMOT inverter and motor. When the MOVIMOT inverter is installed close to the motor, set DIP switch S1/ 5 to "ON". For combinations of "MOVIMOT and motor with one lower power rating", check the setting of DIP switch S1/6. Lower ambient temperature Prevent heat build-up Reduce the load on the motor Increase the speed Check the combination of the drive and MOVIMOT inverter if the fault is signaled shortly after the first enable. The temperature monitoring in the motor (TH winding thermostat) has tripped when using MOVIMOT with the selected extra function 5 Reduce load on the motor. Reset the error by switching off the DC 24 V supply voltage or resetting the error. Increase the set ramp time Brake inspection (see "DR/DV/DT/DTE/DVE Series AC Motors" operating instructions") Check brake coil connection Contact SEW Service Check the combination of the drive (brake coil) and MOVIMOT inverter if the fault is signaled shortly after the first enable. For combinations of "MOVIMOT and motor with one lower power rating", check the setting of DIP switch S1/6. Reset the error by switching off the DC 24 V supply voltage or resetting the error. Defective EEPROM Contact SEW Service. Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
43 Service Replacing units Replacing units DANGER When working on the unit, dangerous voltage levels may still be present up to one minute after the power supply is disconnected. Severe or fatal injuries from electric shock. Disconnect the MOVIMOT drive from the supply system and secure it against unintentional reconnection to the voltage supply. Then wait at least for 1 minute. 1. Remove the screws and take off the MOVIMOT inverter from the terminal box. 2. Compare the data on the nameplate of the previous MOVIMOT inverter with the data on the nameplate of the newmovimot inverter. NOTICE The previous MOVIMOT inverter can only be replaced by a MOVIMOT inverter with the same power rating and the same input voltage. 3. Set all the controls (DIP switch S1, DIP switch S2, setpoint potentiometer f1, switch f2, switch t1) on the new MOVIMOT inverter in the same way as the controls of the previous MOVIMOT inverter. 4. Make sure that no Drive-ID module for DR motor types is plugged into the MOVIMOT inverter [1] [1] Slot for Drive-ID module 5. Place the new MOVIMOT inverter onto the terminal box and screw it on. 6. Supply voltage to the MOVIMOT inverter. Check whether the new MOVIMOT inverter is functioning properly. Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
44 10 Declaration of Conformity Replacing units 10 Declaration of Conformity EC Declaration of Conformity Bruchsal Johann Soder Place Date Managing Director Technology a) b) a) Authorized representative for issuing this declaration on behalf of the manufacturer b) Authorized representative for compiling the technical documents Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV
45
46
47
48 SEW-EURODRIVE Driving the world SEW-EURODRIVE Driving the world SEW-EURODRIVE GmbH & Co KG P.O. Box 3023 D Bruchsal/Germany Phone Fax
Addendum to the Operating Instructions
Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions MOVIMOT with AS-Interface and AC Motor DT/DV Unit Replacement MOVIMOT MM..C -> MM..D with MLK3A
Installation and safety instructions for AC/DC built-in devices
The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
Digi-Motor Installation Guide
Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
A1000 Cheat Sheet (Open Loop Vector)
A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to
Operating instructions
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 [email protected] www.ebmpapst.com CONTENTS 1. SAFETY REGULATIONS AND S 1.1 Levels of hazard
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
ABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
TIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
Technical Description. Transistor D.C. Chopper Controller Type GS 24 S
Technical Description Transistor D.C. Chopper Controller Type GS 24 S Table of contents 1. Getting started guide 2. General information 2.1. Characteristics 2.2. Accessories 3. Information about the Machine
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.
FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and
Electronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
Number 1 in efficiency
PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter Why
Operating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited
PHOENIX CONTACT - 2012-12-14. Features
Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
ACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
Operating Instructions MOVITRAC LTP-B
Drive Technology \ Drive Automation \ System Integration \ Services Operating Instructions MOVITRAC LTP-B Edition 06/2012 19440413 / EN SEW-EURODRIVE Driving the world Contents Contents 1 Important Notes...
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
Contactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
IEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual
IEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual 7/09 MN301 Table of Contents Section 1 General Information.................................................. 1-1 Overview........................................................
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in
Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.
The perfect solution for basic servo applications Brochure May 2011 SINAMICS Answers for industry. with 1FL5 servomotors The solution for basic servo applications There is a requirement to automate motion
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008
CAT AVR V2.3 Voltage regulator for generators March 2008 Instruction Manual Warnings WARNING The system should not be installed, operated, serviced or modified except by qualified personnel who understand
Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
VLT Series 3500 Adjustable Frequency Drive Instruction Manual
Adjustable Frequency Drive Instruction Manual VLT Series 3500 Instruction Manual 175R5237 - Document Version 5.00 This manual applies to all VLT Series 3502-3800 Adjustable Frequency Drives with software
CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual
Instruction Manual OPC-LM1-IL Option Card for Encoder of Line Driver Output CAUTION Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual
Mounting Instructions. Torque Transducer. A0329 3.2 en
Mounting Instructions Torque Transducer T5 T5 Contents 3 Page Safety instructions.............................................. 4 1 Measuring characteristics..................................... 7 2 Mounting.....................................................
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
Addendum to the Operating Instructions
Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions Safety-Rated Encoders Functional Safety for CMP Synchronous Servomotors CMP40 CMP100 CMPZ71 CMPZ100
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
Contact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011
, 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.
LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems
LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
Givare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
Safety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVIDRIVE MDX60B/61B Functional Safety
Drive Technology \ Drive Automation \ System Integration \ Services Manual MOVIDRIVE MDX60B/61B Functional Safety Edition 09/2010 17019613 / EN SEW-EURODRIVE Driving the world Contents Contents 1 Important
Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
MINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
Electric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA
w VOLTAGE MONITORING RELAY UR5U1011 w SCHRACK-INFO AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design w TECHNICAL DATA 502 1. Functions
REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)
SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY
Description. Dimensions. Features. www.pwb-encoders.com. precision works better
Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Quick Start Instructions. Frequency Inverter. Series KFU 2- / 4- 0,55 to 3,0 kw 230 V KFU 2-0,55 to 132 kw 400 V KFU 4- KN 621.
Quick Start Instructions Frequency Inverter Series KF 2- / 4-0,55 to 3,0 kw 230 V KF 2-0,55 to 132 kw 400 V KF 4- KN 621.1401e This documentation describes the first steps for an easy commissioning of
StructureScan HD Module. Installation Guide ENGLISH. www.bandg.com www.simrad-yachting.com www.lowrance.com
StructureScan HD Module Installation Guide ENGLISH www.bandg.com www.simrad-yachting.com www.lowrance.com Disclaimer As Navico is continuously improving this product, we retain the right to make changes
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
How To Use The Vacon 0 Machinery
vacon 0 machinery how would you like your ac drive today? easy adaptation for customer requirements The Vacon 0 Machinery is an extremely compact AC drive for machine builders in the power range from 0.25
Installation and Operating Instructions for ROBA -takt Control Unit Type 014.000.2
Manufacturer s Declaration This product is intended f installation in a machine system, based on the machine directive 006/4/EC. It is fbidden to start use of the product until the machine system into
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
Technical data UNIBLOCK UBSF 180 625
Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power
Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
Relés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
EPM3. Phase Sequence and Motor Rotation Tester. Users Manual
EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR
ST Series POWER SUPPLIES USER INSTRUCTIONS
Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional
Type: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket
Technical Datasheet SNK64D00 Catalogue Page SNK64S00 ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket - Ease your test operations with the built-in test sockets, - Screwdriver
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
Elektromotoren und Gerätebau Barleben GmbH
Elektromotoren und Gerätebau Barleben GmbH OPERATING INSTRUCTIONS Transformer Protection Relay NM Series (Buchholz principle) Elektromotoren und Gerätebau Barleben GmbH Table of contents Page 1. Safety
CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual
Instruction Manual Option Card for Frequency Divider Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual and understand the description
Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of