Actuator controls AUMATIC ACExC 01.2 Profibus DP
|
|
- Jeffry Davidson
- 7 years ago
- Views:
Transcription
1 Actuator controls AUMATIC ACExC 01.2 Profibus DP To be used in combination with the operation instructions only! The present short instructions do NOT replace the operation instructions! They are only intended for persons already familiar with the operation instructions where safety instructions, assembly, operation and commissioning are already described in detail! The operation instructions must always be available. Short instructions FO connection
2 Table of contents Table of contents 1. Short description FO connection Basic information 2.2. Terminal compartment: open 2.3. FO cables: connect 2.4. Terminal compartment: close 3. Network topologies Line topology 3.2. Star topology 3.3. Ring topology (two-fibre ring) 4. Corrective action LED indications 4.2. Troubleshooting Line and star topology Ring topology 5. Technical data FO coupler 6. Appendix Calculation of achievable FO range 6.2. Measuring methods 6.3. Reference addresses 6.4. Literature Page
3 Short description 1. Short description AUMA actuator controls with FO connection are intended for use in optical fieldbus networks. The FO connection integrated in the electrical connection enables the conversion from electrical RS-485 signals into optical signals and vice versa. FO connection behaviour is transparent at the bus, i.e. control of AUMA actuators via bus is identical to control via copper cables (RS-485). Contrary to RS-485 based systems, different topologies are possible: Line topology Star topology Redundant ring topology Apart from the large distances, FO cables offer further advantages: In environments with electromagnetic interference Lightning arrester or overvoltage protection Equipotential earth bonding and earthing Galvanic separation of the actuator Use of common cable trenches for power and signal cables Prevention of interference emissions along the transmission line This allows for customised solutions and various applications such as water/waste water industries, tunnelling, power plants, thermal industry or telecontrol engineering. 3
4 FO connection 2. FO connection 2.1 Basic information Hazardous voltage! Risk of electric shock. Failure to observe this warning can result in death or serious injury. The connection must be carried out exclusively by suitably qualified personnel. Prior to opening: Disconnect both system and device from the mains. Observe basic information contained in this chapter. Observe safety instructions contained in the operation instructions pertaining to the actuator. Eye damage caused by open fibre optic cable ends! NEVER look directly into open cable ends or FO cable connections. Connection or receive problems when ignoring the installation instructions! Only use FO cable connection (connector types) with the wiring techniques indicated in these instructions. Only mount connector types with locking mechanisms in the defined position. Protect unused FO cable connections against contamination or dust with protective caps/plugs supplied by the factory. Connect incoming FO cable with the optical receiver, the outgoing FO cable with the optical sender. NOT vice versa! Do NOT kink FO cables! Observe bending radius of cable manufacturer. Cable and wire types Table 1: Cables and wires according todin VDE 0888 part 3: Core diameter Fibre Range Damping coefficient 62.5 µm or 50 µm 62.5/125 µm Multi-mode graded-index fibre 50/125 µm glass fibre 62.5/125 µm: 2,600 m 50/125 µm: 1,400 m Recommendation: < 3.0 db/km Remove outer sheathing of FO cable at a length of approx. 25 cm to enable ring wiring in the terminal compartment. Figure 1: Plug type FSMA Controls mounted to wall bracket In the event of heavy vibration of the valve, we recommend mounting the actuator controls separately from the actuator on a wall bracket. For information about the wall bracket, refer to operation instructions for the actuator. 4
5 FO connection 2.2 Terminal compartment: open Figure 2: Plug/socket connector: left KES, right KES flameproof [1] Cover [2] Screws for cover [3] O-ring [4] Terminal compartment: Type of protection Ex e [5] Terminal compartment: Type of protection Ex d [6] Frame Hazardous voltage! Risk of electric shock. Disconnect device from the mains before opening. 1. Loosen screws [2] and remove cover [1]. Terminal compartments [4] and [5] are designed either in type of protection Ex e (increased safety) or in type of protection Ex d (flameproof enclosure).hereby, the flameproof interior compartment of the actuator (Ex d) remains closed. 2. Insert cable glands with Ex e approval and suitable for connection cables. The enclosure protection IP stated on the name plate is only ensured if suitable cable glands are used. Example: Name plate shows enclosure protection IP Seal cable entries unused cable entries with approved plugs suitable for the required protection type. 4. Remove cable sheathing and insert the wires into the cable glands. 5. Fasten cable glands with the specified torque to ensure required enclosure protection. 5
6 FO connection 2.3 FO cables: connect 1. Remove safety circlip and take FO coupler off top head rail. Figure 3: FO coupler on top head rail 2. Place FO coupler on fixing plate in "parking position" Figure 4: FO coupler in "parking position" 3. Insert FO cables through cable glands. 4. Link FO connectors crosswise: Optical output of actuator 1 with optical input of actuator 2. Optical input of actuator 1 with optical output of actuator 2. Figure 5: Connection example 6
7 FO connection 2.4 Terminal compartment: close Figure 6: Plug/socket connector: left KES, right KES flameproof [1] Cover [2] Screws for cover [3] O-ring [4] Terminal compartment: Type of protection Ex e [5] Terminal compartment: Type of protection Ex d [6] Frame 1. Clean sealing faces of cover [1] and housing. 2. Plug/socket connector designed as KES flameproof: Preserve joint surfaces with an acid-free corrosion protection agent. 3. Check whether O-ring [3] is in good condition, replace if damaged. 4. Apply a thin film of non-acidic grease (e.g. petroleum jelly) to the O-ring and insert it correctly. Flameproof enclosure, danger of explosion! Risk of death or serious injury. Handle cover and housing parts with care. Joint surfaces must not be damaged or soiled in any way. Do not jam cover during fitting. 5. Fit cover [1] and fasten screws [2] evenly crosswise. 7
8 Network topologies 3. Network topologies 3.1 Line topology When connecting several field devices (actuators) in a network, the structure is called network topology. AUMA offers different network topologies. Figure 7: Structure for line topology Max. FO cable range in km (observe technical data!) [1] FO T-coupler within electrical connection of ACExC 01.2 [2] FO PP-coupler within DCS (imperatively required) [3] FO PP-coupler for any Profibus DP field device [4] Any Profibus DP field device Table 2: Number of FO devices (actuators) connected in series Baud rate [kbit/s] ,500 Maximum number of FO devices Special features of line topology The optical signal is converted into an electrical signal at each device. Prior to transmission to the next device, the electrical signal is converted into an optical signal. Interruption of an FO cable (case A) or failure of an FO connection board (case B) results in loss of control for the subsequent actuators: Case A (standard) As soon as the electrical connection is removed from the ACExC 01.2, FO connection of this actuator is no longer available. As a consequence, communication with the subsequent actuators is lost. To prevent this, FO connection used in the ACExC 01.2 can also be externally supplied with 24 V DC. 8
9 Network topologies Case B (option) As soon as the actuator is switched off (motor voltage), the FO connection board of this actuator is no longer available. As a consequence, communication with the subsequent actuators is lost. To prevent this, the complete ACExC 01.2 can be externally supplied with 24 V DC. 3.2 Star topology Figure 8: Structure for star topology Max. FO cable range in km (observe technical data!) [1] FO PP-coupler within electrical connection of ACExC 01.2 [2] LWL Stich-Koppler in der Leittechnik (zwingend erforderlich) [3] LWL Stich-Koppler für Beliebiges Profibus DP Feldgerät [4] Any Profibus DP field device Table 3: Number of FO devices (actuators) connected in series Baud rate [kbit/s] ,500 Maximum number of FO devices Special features of star topology Failure of an FO cable section or of an actuator's FO connection board has no impact on the operability of the remaining actuators. 9
10 Network topologies 3.3 Ring topology (two-fibre ring) Figure 9: Structure for ring topology Max. FO cable range in km (observe technical data!) [1] FO ring coupler within electrical connection of ACExC 01.2 [2] FO ring coupler within DCS (imperatively required) [3] FO ring coupler for any Profibus DP field device [4] Any Profibus DP field device Information Maximum number of FO device (actuators) connected in series is 36. Special features of ring topology The interruption of an FO cable between two actuators is recognised by the redundancy modules. Both display and bus indicate: Wrn FOC. The network is then operated as an optical line and all actuators remain available. If one module fails (i.e. when power supply is interrupted), only the actuator connected to this module is disconnected from the ring, the remaining network stays operative as a line. All other actuators remain available. The actuators have a redundant FO cable connection with a standard Profibus DP interface (not redundant). Special features of the ring topology during configuration T ring The following conditions have to be met for the optical ring Configuration of a non-existent bus station with the highest possible bus address. Increase of the retry value to a minimum of 3. Check slot time and set to a minimum of 900. Calculation of run times within the ring: T ring = (n 1) * T FO coupler + L * t FO Max. run time within the ring 10
11 Network topologies n T FO coupler L T FO Number of FO couplers within the ring Module run time of the signals within the FO coupler = 4.5 ms Length of the FO cables within the ring Run time per metre FO = 5 ns The values indicated in the table apply to Profibus DP. Data rate [kbit/s] 1, Slot time [bit times/km] T ring Run time within Max. distance between two FO ring [ms] couplers [km] The FO coupler connected to the master via copper cable has to be a master module. Only one master module is allowed within the ring. Cable routing and PLC fault evaluation To increase service safety, install cables for go-and-return in the ring on separate lines. To achieve complete monitoring of the redundant optical ring, all FO fault indications (including the fault output of the FO coupler at the master) must be evaluated by the PLC controls. 11
12 Corrective action 4. Corrective action 4.1 LED indications Figure 10: LEDs on FO coupler [BA] [U] L [F] Bus active (yellow) Operation (green) Fault channel 1/2 (multicolour) ring coupler only Table 4: LED Colour BA U L yellow green Summary of functions Function Ring topology only: F LED flackert: Data from RS485 channel are transmitted via the optical interface. LED is illuminated: Power supply (24 V DC) for FO coupler is available Internal operating voltage (5 V) is available. This fault LED can be used to check the FO connections. Ein Profibus Master ist hierzu nicht erforderlich red yellow orange LED is illuminated in red: Channel 1 receives no signal. LED is illuminated in yellow: Channel 2 receives no signal. LED is illuminated in orange: Both channels do not receive any signal. LED is not illuminated: Input cables to the two adjacent FO couplers are in perfect condition. Information 4.2 Troubleshooting If the fault LED [F] is illuminated (red, yellow or orange), the indication is sent at the same time via display and Profibus DP: Wrn FOC. Wrn FOC indication can be read via fieldbus interface in the process representation input (byte 19). For an overview and a detailed description of all input data, refer to Manual (Device integration fieldbus) AC 01.2/ACExC Limitation: The Wrn FO cable budget and Wrn FOC connection indications represented in byte 20 are not generated for explosion-proof version with FO cables. LEDs on the FO couplers provide important information for troubleshooting. The following tables of this chapter provide basic steps for troubleshooting and elimination via these LEDs. 12
13 Corrective action Line and star topology Furthermore, different fieldbus interface states can be requested via the ACExC 01.2 display (Menu Diagnostic M0022). For further information, please refer to Manual (Device integration fieldbus) AC 01.2/ACExC Table 5: Troubleshooting table Can actuator be controlled via fieldbus? Green LED [U L ] illuminated? Verify power supply (24 V DC) of the FO coupler: Is yellow LED [BA] flickering? Yes No Yes No Power supply (24 V DC) available? Power supply (24 V DC) not available? Yes No Causes and remedies Continue with 4 Continue with 2 FO coupler supplied with voltage (24 V DC). Continue with 4 Continue with 3 Possible causes and remedies: FO coupler is defective Replace coupler. Remedies: Check fuses within ACExC Restore power supply. Possible causes: Sender on coupler defective FO connection of sender not operable Possible causes: Slave not properly connected Slave defective Master defective FO coupler receiver or FO connection of receiver defective Is the required FO coupler (BARTEC order no.: WP/6000 or /4000) installed at the master? Ring topology Troubleshooting Is the connection between FO coupler and device correct? Have all screw-type terminals been tightened correctly? Has the proper interface been selected? Is the transmission distance too long? Is the optical sender connected to the optical receiver of the opposite device? Are the bus termination resistors activated? Is an FO coupler, type BARTEC WP/5400, connected to the fieldbus master? Is there more than one master module in the ring? Table 6: Troubleshooting table Can actuator be controlled via fieldbus? Green LED [U L ] illuminated? Verify power supply (24 V DC) of the FO coupler: Yes No Yes No Power supply (24 V DC) available? Power supply (24 V DC) not available? Causes and remedies No fault Continue with 2 FO coupler supplied with voltage (24 V DC). Continue with 6 Continue with 3 Possible causes and remedies: FO coupler is defective Replace coupler. Remedies: Check fuses within ACExC Restore power supply. 13
14 Corrective action Fault LED [F] illuminated? Check connection to adjacent FO coupler (fieldbus device): Connector ok? Gelbe LED [BA] flackert? Check adjacent FO coupler (fieldbus device): FO coupler ok? Ja: LED illuminated in red, yellow or orange? Causes and remedies Continue with 5 No (LED is not illuminated) Continue with 6 Yes No Yes No Yes No Possible causes and remedies: Receiver at FO coupler defective Sender at adjacent FO coupler defective Check FO cable. Remedies: Correct connection (connect optical output to optical input). Possible causes and remedies: Sender at coupler defective FO connection of sender not operable Continue with 7 Possible causes: Slave not properly connected Slave defective Master defective Possible causes: Error in control program Check adjacent FO coupler (fieldbus device). 14
15 Technical data 5. Technical data Information The following technical data includes standard and optional features. For detailed information on the customer-specific version, refer to the order-relevant data sheet. This data sheet can be downloaded from the Internet at in German and English (indication of commission number required). 5.1 FO coupler Explosion protection (in accordance with EN to EN 50020) Ex de [ib] IIC EC type examination certificates Mounting: TÜV 99 ATEX 1404 Coupler: PTB 97 ATEX 1068 U X FO connection Channels (optical) Data rate Transmission type Fibre Optical budget Network range max. Wave length Operation temperature Power supply Indications (LEDs) Suitable bus systems Required FO modules for the master Maximum number of FO actuators FSMA FO plug/socket connector For line topology: 1 x IN/OUT or 2 x IN/OUT For star topology: 1 x IN/OUT For ring topology: 2 x IN/OUT Maximum 1.5 Mbits/s Half-duplex Multi-mode, 62.5 (50)/125 µm 8 db at 62.5 µm 4 db at 50 µm fibre 62.5 µm glass fibre: 2,600 m (FO cable damping max. 3.0 db/km, without additional damping) 50 µm glass fibre: 1,400 m (FO cable damping max. 3.0 db/km, without additional damping) 850 nm 25 C to +60 C 24 V DC/75 ma, internally supplied via power supply unit of ACExC For line and star topology: External power supply of the ACExC 01.2 with 24 V DC/500 ma possible. Only when the ACExC 01.2 is operated on external voltage supply will the bus remain uninterrupted in case of a loss of operating voltage. LED UL (green) = device ready for operation (power supply available) LED BA (yellow) = bus active: Data is received via the RS485 channel. For ring topology: LED fault (multicolour) = bus status Profibus DP Bartec, to be purchased from AUMA or FO coupler for line or star topology - 1 channel FO PP coupler (BARTEC order no.: WP/6000) (AUMA order no.: K ) - 2 channel FO T coupler (BARTEC order no.: WP/4000) (AUMA order no.: K ) FO coupler for ring topology: - 2 channel FO ring coupler (BARTEC order no.: WP/5400) (AUMA order no.: K ) coupler at the master (at kbit/s) 15
16 Appendix 6. Appendix 6.1 Calculation of achievable FO range L max P a K Anz K a L Maximum achievable cable length of FO cable/wire[km] Optical budget [db] (connectible power). Damping of the couplings [db]. Typical values for FST = db, for FSMA = db. Additional number of FO couplings within the FO cable between two actuators (excluding FO couplings at electrical connection of AUMA actuators; damping of these actuators is already included in the optical budget). Specific cable damping [db/km], refer to technical data of the FO cable. Example 1 Standard set-up, i.e. no additional couplings: P = 8 db; Anz K = 0; a K = 0.6 db; a L = 3.0 db/km L max = 2,600 m Example 2 Two couplings within the cable: P = 8 db; Anz K = 2; a K = 0,6 db; a L = 3,0 db/km L max = 2,200 m Figure 11: Example: Two couplings within the cable [1] 1 st FSMA a K coupling = 0.6 db [2] 2 nd FSMA a K coupling = 0.6 db 16
17 Appendix 6.2 Measuring methods Figure 12: Damping measurement 6.3 Reference addresses Required FO module for the master: BARTEC Top Holding GmbH Max-Eyth-Straße 16 D Bad Mergentheim Germany Tel.: Fax: FO cables and wires: Network reliability despite multiple points of failure eks Engel GmbH & Co. KG Schützenstr. 2, Wenden-Hillmicke, Tel.: , Literature Christoph P. Wrobel Optische Übertragungstechnik in der Praxis Grundlagen, Komponenten, Installation, Anwendungen Hüthig Verlag ISBN
18 18
19 19
20 AUMA Riester GmbH & Co. KG P.O.Box 1362 D Muellheim Tel Fax riester@auma.com Y /003/en/1.13 For detailed information on AUMA products refer to the Internet:
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
More informationPractical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University
Practical steps for a successful PROFIBUS Project Presented by Dr. Xiu Ji Manchester Metropolitan University Basics of PROFIBUS Content Practical steps in the design and installation stages Segmentation:
More informationFIBER OPTIC APPLICATION IN A PROFIBUS NETWORK
FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK Field busses are industrial control systems using Programmable Logic lers (PLC) to control and manage field devices found in industrial environments. The communication
More informationABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
More informationR4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
More informationOperating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationABB Drives. User s Manual HTL Encoder Interface FEN-31
ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions
More informationProduct Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
More informationActuator controls. AUMATIC AC 01.1 ACExC 01.1 Profibus DP. Operation instructions
Actuator controls AUMATIC AC. ACExC. Operation instructions Actuator controls AUMATIC AC. / ACExC. Operation instructions Scope of these instructions: These instructions are valid for multi-turn actuators
More information7 Lighting Technology
7 Lighting Technology Series HS6145 For use in Zone 1 and Zone 2 Comply with requirements of Fire Department standard DIN 14 462 Battery state display Deep discharge protection Open circuit monitor Light
More informationMINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
More informationDVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual
DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages
More informationProgrammable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
More informationTerminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
More informationTX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
More informationL5354 ControlNet Communications Interface
L5354 ControlNet Communications Interface Technical Manual HA470733 Issue 2 Copyright SSD Drives Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or
More informationFerrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
More informationConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide
31007950 7/2009 ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide 7/2009 31007950.02 www.schneider-electric.com NOTICE Read these instructions carefully, and look at the equipment to become
More informationFN2001-A1 Network module (SAFEDLINK) Mounting Installation
FN00-A Network module (SAFEDLINK) Mounting Installation A6V050_f_en_-- 05-0-6 Building Technologies Division Legal notice Legal notice Technical specifications and availability subject to change without
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
More informationOptions for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface
Options for ABB drives, converters and inverters User s manual FDPI-02 diagnostics and panel interface Table of contents Table of contents 3 1. FDPI-02 diagnostics and panel interface Safety..............................................
More informationABB RTU560A Series CMU & Modules
ABB RTU560A Series CMU & Modules 1KGT 150 648 V1.02 March 4, 2012 Slide 1 Contents RTU560A rack solutions March 4, 2012 Slide 2 560CSR01 Available for wall mounting and swing frame Supports redundant power
More informationProcess modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationDocumentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20
Documentation for KL2602 and KL2622 Two-channel Relay Output Terminals for 230 V AC / 30 V DC Version: 1.4 Date: 2013-03-20 Table of contents Table of contents 1 Foreword 1 1.1 Notes on the documentation
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
More information8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationComponents for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.
> Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
More informationPROFIBUS. Installation Guideline. for Planning
PROFIBUS Installation Guideline for Planning Version 1.0 Aug 2009 Order No: 8.012 Introduction PROFIBUS Order No: 8.012 Identification: Office-07-0002 This document has been created by the Installation
More information8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide
8-port 10/100Base-TX +2-port 100Base-FX Switch User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by
More informationMounting instructions. Junction box VKK2R-8 DIGITAL. A1145-1.0 en
Mounting instructions Junction box VKK2R-8 DIGITAL VKK2R-8 DIGITAL 3 Contents Page Safety instructions... 4 1 Introduction and appropriate use... 7 2 Mechanical construction... 8 2.1 Mounting... 9 3 Electrical
More informationPROFIBUS fault finding and health checking
PROFIBUS fault finding and health checking Andy Verwer Verwer Training & Consultancy Ltd PROFIBUS PROFIBUS is a very reliable and cost effective technology. It is common to find extensive installations
More informationIntroduction to PROFIBUS and PROFINET
Introduction to PROFIBUS and PROFINET Andy Verwer Technical Officer for PROFIBUS UK Verwer Training & Consultancy Ltd Gold distributor PROFIBUS Characteristics PROFIBUS is a bi-directional digital communication
More informationAddendum to the Operating Instructions
Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions MOVIMOT with AS-Interface and AC Motor DT/DV Unit Replacement MOVIMOT MM..C -> MM..D with MLK3A
More informationPSI-MOS-RS485W2/FO 850 T
Extract from the online catalog PSI-MOS-RS485W2/FO 850 T Order No.: 2708326 FO converter with integrated optical diagnosis, alarm contact, for RS-485 2-wire bus systems (SUCONET K, MODBUS...) up to 500
More informationHARTING econ 3000 Introduction and features
HARTING Introduction and features HARTING es, unmanaged, for installation in control cabinets General Description Features The Fast es of the product family HARTING are suitable for industrial applications
More informationCompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
More informationTX2123 RS485 TO ETHERNET ADAPTOR
TX2123 RS485 TO ETHERNET ADAPTOR Converts Datacomms between fibre optic Modbus TCP over Ethernet and hard-wired copper Modbus RTU over RS485 Fibre Optic MODBUS TCP/ IP Ethernet Copper MODBUS RTU RS485
More informationCMC III Temperatur-/ Feuchtesensor CMC III Temperature/ Humidity Sensor
CMC III Temperatur-/ Feuchtesensor CMC III Temperature/ Humidity Sensor 7030.111 Montage-, Installations- und Bedienungsanleitung Assembly and operating instructions Foreword Foreword Dear Customer, Thank
More informationInstruction Bulletin. MCS025 Sync-Check Module Installation Sheet
Instruction Bulletin 63230-216-244B1 LaVergne, TN, USA MCS025 Sync-Check Module Installation Sheet Retain for future use. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Only qualified electrical
More informationSiemens AG 2010. Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.
Fieldbus solutions with the SIMATIC PCS 7 distributed control system Brochure April 2010 SIMATIC PCS 7 Answers for industry. Fieldbus solutions with SIMATIC PCS 7 OS multi-clients Engineering station Maintenance/
More informationReliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS
STORAGE and HANDLING The LED Illuminator meets or exceeds all applicable specifications when shipped from the factory. All units should be inspected upon receipt to ensure that no damage has been incurred
More informationTechnical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
More informationFiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply
More informationElektromotoren und Gerätebau Barleben GmbH
Elektromotoren und Gerätebau Barleben GmbH OPERATING INSTRUCTIONS Transformer Protection Relay NM Series (Buchholz principle) Elektromotoren und Gerätebau Barleben GmbH Table of contents Page 1. Safety
More informationMy first Hirschmann: The SPIDER family of switches.
My first Hirschmann: The SPIDER family of switches. Large selection of entry level switches Compact design Simple rail installation Industry standard 24 V supply voltage Plug & Play gets you up and running
More informationMagnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6
More informationOZW30. Central Unit SYNERGYR
2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control
More informationRLH 2 Wire Digital Phone Fiber Link Card System
RLH Industries, Inc. The leader in rugged fiber optic technology. USER GUIDE! Unconditional Lifetime Warranty U-008 2014C-0924 RLH 2 Wire Digital Phone Fiber Link Card System CARD INSTALLATION INFORMATION
More informationUniversal Serial Bus (USB) to DH-485 Interface Converter
Installation Instructions Universal Serial Bus (USB) to DH-485 Interface Converter Catalog Number 1747-UIC Contents Overview..................................................3 Computer and Operating System
More informationElectric actuators. with fieldbus interface. Information
Electric actuators with fieldbus interface Information Applications AUMA actuators are used wherever the flow through pipelines has to be controlled or regulated. They are the crucial link between the
More informationExtract from the online catalog
Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http://www.download.phoenixcontact.com. The
More informationOperating Instructions
Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4
More informationWEB log. Device connection plans
WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20160425* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,
More informationEX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL
PRODUCT NAME: CP/PB -150- EXPLOSION-PROOF-MANUAL CALL POINT/ PUSH BOTTON DOC NO.: EX-TECH SAS-12-CP-PB150-TM REV01 EXPLOSION-PROOF MANUAL CALL POINT/ PUSH BOTTON II 2GD EPL Gb, Db Ex d IIC T6, IP66 Ex
More informationINFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
More informationFast Ethernet FX-TX Media Converter. User Manual RINGDALE
Fast Ethernet FX-TX Media Converter User Manual RINGDALE Introduction The Fast Ethernet FX-TX Media Converter Provides an ideal solution for extending the cable length of your network, or a way of interconnecting
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
More informationGAE953 Electrical Alarm Unit 19" with Indicator
Master Instruction 08.95 MI EIO2211 A-(en) GAE953 Electrical Alarm Unit 19" with Indicator The electrical alarm unit GAE953 gives a signal when one or two set alarm values have been exceeded. Input signals
More informationSIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M
SIMATIC NET Industrial Ethernet switches MM900 media modules for SCALANCE XR-500M Compact Operating Instructions Legal information Qualified Personnel The product/system described in this documentation
More informationLENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space
PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space LENORD +BAUER... automates motion. Technical information Version 2014-09 General The PowerDRIVE-Positioning
More informationTelephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
More informationIntroduction. In this Self-study Programme we will explain to you the design and function of the CAN data bus. SSP 186/01
Introduction The requirements relating to driving safety, driving comfort, exhaust emissions and fuel economy are are becoming ever more stringent. This entails more intensive information exchange between
More informationOriginal instructions Tina 3A/Aps Adaptor unit
Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
More informationMGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders
MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders General The MGL Avionics CAN bus interface for the Trig Avionics TT21 and TT22 transponders provides a simple solution to allow any
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationInstallation and Start-up Guide. CS 31 Adapter Module NCSA-01
ABB Drives Installation and Start-up Guide CS 31 Adapter Module NCSA-01 CS 31 Adapter Module NCSA-01 Installation and Start-up Guide 3BFE 58920029 R0225 EFFECTIVE: 1.12.1999 SUPERSEDES: 1996-02-01 1999
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
More informationSYSTEM 45. C R H Electronics Design
SYSTEM 45 C R H Electronics Design SYSTEM 45 All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, & A outputs. Independent 25
More informationISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt
Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt TDB106015en/05.2013 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)
More informationIFEA Industriell kommunikasjon. AS-i Training
IFEA Industriell kommunikasjon 1 Agenda AS-i safety basics Safety Output ASIMON 3G2 Current Devices Troubleshooting Safety 2 3 4 AS-i Safety at Work 5 Safety at work - Headlines Integration of all binary
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationST Series POWER SUPPLIES USER INSTRUCTIONS
Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional
More informationOPT-700 - SERIAL TO FIBER OPTIC CONVERTER
USER S MANUAL OPT-700 - SERIAL TO FIBER OPTIC CONVERTER JUL / 05 OPT-700 VERSION 1 TM FOUNDATION OPT700ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date
More informationTroubleshooting and Diagnostics
Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem
More informationA good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,
More informationIIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel
Explosion protection Description Flameproof enclosures BARTEC B or EJB series are designed to be installed in industrial plants, where potential hazardous atmospheres occur. These areas are either classified
More informationDisplayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters
Description Displayport combines the audio and video through an interface. It supports high resolution displays and multiple displays with a single cable, and increases the efficiency and bandwidth of
More informationMINIMAT-EC-Servo Screwdriver Spindles
Screwdriving technology Automation Air motors Air tools Screwdriver Spindles electric MINIMAT-EC-Servo Screwdriver Spindles Maximum Flexibility and process Control Straight Spindle Form - Torque range
More informationMCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
More informationVOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide
VOT-320 VOT-320V0xxL VOT-320V0xxH en Quick Installation Guide VOT-320 Table of Contents en 3 Table of Contents 1 General information 4 2 Parts included 5 3 Unpacking 6 4 Installing and connecting 7 4.1
More informationSYSTEM DESCRIPTION Termination Boards
PROCESS AUTOMATION SYSTEM DESCRIPTION Termination Boards Non-IS Termination Boards for Yokogawa CENTUM C3 and ProSafe RS ISO9001 With regard to the supply of products, the current issue of the following
More informationSYSTEM 4C. C R H Electronics Design
SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25
More informationHARTING mcon 1000 Introduction and features
Introduction and features HARTING mcon 1000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features Supporting Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s)
More information19 LED Tube Controller ORDERCODE 41003
19 LED Tube Controller ORDERCODE 41003 Congratulations! You have bought a great, innovative product from Showtec. The Showtec 19 LED Tube Controller brings excitement to any venue. Whether you want simple
More information5-port 10/100Base-TX Industrial Switch (314500) User s Guide
5-port 10/100Base-TX Industrial Switch (314500) User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by
More informationCombi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
More informationTina 2A/B Adaptor unit
Original instructions Tina 2A/B Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
More informationPower Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
More informationCompact pressure switch Flameproof enclosure Ex d Model PCA
Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring
More informationPlug and Socket Devices SolConeX 16 A Series 8570
www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control and signalling purposes > arge switching handle
More informationLaser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
More informationDigi-Motor Installation Guide
Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support
More informationPSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.
PSDC 08128 v.1.2 PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. EN** Edition: 9 from 25.05.2015 Supersedes the edition: 8 from 12.12.2014 the 8x 1A/12V DC power output for powering
More informationStructured Cabling, Earthing & Equipotential Bonding
White Paper Information and Communication Technology Structured Cabling, Earthing & Equipotential Bonding English Rev. 1.0.1 / 2012-06-01 1 Abstract All Dallmeier network products (PoE cameras, recorders,
More information