IWAKI AMERICA MDM SERIES MAGNETIC DRIVE PUMP INSTRUCTION MANUAL
|
|
|
- Willa Shelton
- 9 years ago
- Views:
Transcription
1 IWAKI AMERICA MDM SERIES MAGNETIC DRIVE PUMP INSTRUCTION MANUAL
2 MDM SERIES INSTRUCTION MANUAL Table of Contents 1 UNPACKING AND INSPECTION MODEL IDENTIFICATION GUIDE SPECIFICATIONS HANDLING INSTRUCTIONS INSTALLATION, PIPING, AND WIRING... 9 INSTALLATION POSITION... 9 PIPING SUCTION PIPING DISCHARGE PIPING WIRING OPERATION NOTES ON OPERATION START-UP PREPARATION STARTING OPERATION STEPS STOPPING OPERATION STEPS MAINTENANCE AND INSPECTION DAILY INSPECTION PERIODIC INSPECTION REPLACEMENT TOLERANCE CHART TROUBLESHOOTING PARTS DESCRIPTION AND EXPLODED VIEW DISASSEMBLY AND ASSEMBLY OF PUMP DISASSEMBLY REPLACEMENT OF REAR THRUST COLLAR, RADIAL BEARING, IMPELLER REASSEMBLY SPARE PARTS DIMENSIONS Rev Q 11/19/2013
3 Thank you for selecting an Iwaki America MDM Series magnetic drive pump. This instruction manual explains the correct handling, operating, maintenance, inspection and troubleshooting procedures for your pump. Please read through it carefully to ensure the optimum performance, safety and long service of your pump. 1 Unpacking and Inspection Open the package and check that the product conforms to your order. Also, check each of the following points. For any problem or inconsistency, contact your distributor at once. 1. Check that the model number and the HP indicated on the nameplate conform to the specifications of your order. 2. Check that all the accessories you ordered are included. 3. Check that the pump body and parts have not been accidentally damaged or that any bolts or nuts have not loosened in transit. IWAKI AMERICA INC. Holliston, MA USA 4. If the pump has shipped without motor, check that the motor adapter is in the proper orientation for your installation. 1
4 2 Model Identification Guide 1. Pump Size MDM 1518 EKK 05 H S Model Suction Discharge Motor HP Motor Frame 1516* 2 145TC, FOOTLESS 1516* 3 182TC, FOOTLESS 1518* 5 184TC, FOOTLESS 1518* TC, W/FEET 1518* TC, W/FEET 1 ½ TC, W/FEET TC, W/FEET TC, W/FEET TC, W/FEET TSC, W/FEET TC, FOOTLESS TC, W/FEET TC, W/FEET TC, W/FEET 2 1 ½ TC, W/FEET TC, W/FEET TC, W/FEET TSC, W/FEET TC, FOOTLESS ½ TC, W/FEET TC, W/FEET 326* TC, W/FEET 326* TC/ W/FEET 326* TC, W/FEET 326* TC, W/FEET 326* TSC W/FEET * Denotes ANSI standard dimensional unit. 2
5 2. Liquid End Construction Bearing option ECF* EKK PKK Casing Liner/Containment Shell Impeller Inner Magnet Radial bearing Carbon fiber reinforced copolymer ETFE High Density Carbon PFA Shaft 99.8% alumina ceramic Front Outboard Thrust Collar 99.8% alumina ceramic SiC Front Inboard Thrust Collar PTFE (w/filler) Rear Inboard Thrust Collar 99.8% alumina ceramic Rear Outboard Thrust Collar PTFE (w/filler) PTFE Casing Gasket PTFE * Dry run capable configuration 3. Motor Size 02, 03, 05, 07, 10, 15, 20, 25 2 HP through 25 HP 4. H = High Temperature Version (only available on and 2158 models) 5. S = Slurry Bearing System 3 Specifications Model Connections Suct x Disch 150# (inch) Nominal Impeller Dia. (inch) BEP (GPM) BEP Head (ft) ½ x Min Flow rate (GPM) 5 Nominal Motor (RPM) Motor (HP) ½ x , 7.5, ½ x x 1½ , 7.5, x 1½ , 10, 15, 20, 25 2, 3 7.5, 10, 15, 20, ½ x , 7.5, X , 10, 15, 20, 25 Notes: 1. Rated performance (head/capacity) represents the maximum discharge head/capacity measured with water at 68 F (20 C). 2. Liquid temperature range: ETFE type: F (0-105 C) PFA type: F (0-120 C) ( and 2158 models) F (0 150 C) * 3
6 F Pumped liquid temp C * For liquid temperatures F ( C) please consult Iwaki America. PFA / ETFE material MDM and 2158 ETFE material All models (except MDM and 2158) PFA material MDM and 2158 high temperature PFA material MDM1516, 1518, 2156, 2526, 326 Ambient temperature range : Ambient humidity range: F (0 40 C) 35 85% RH 3. Max Allowable Working Pressure (MAWP) for MDM1516, 1518, 2156, 2526 and 326 is 150 psi (1.03 MPa). For MDM and 2158 MAWP is 250 psi (1.72 MPa) 4. Slurry: In general, slurries should not be handled. However, a pump with a silicon carbide bearing system, KK, can handle slurries if the hardness is 80Hs or below, with a maximum grain size of 2 MIL (50 microns) and maximum density 10% wt. Consult Iwaki America or your distributor for details regarding applications using slurries greater than 5%. 4
7 Materials of Main Components Material code ECF EKK PKK 1 Front casing liner 2 Rear casing 3 Impeller 4 Inner magnet CFRETFE (carbon fiber reinforced ETFE) 100% PFA 5 Bearing High Density Carbon 6 Shaft High purity Alumina Outboard forward thrust 7 collar Ceramic 8 Inboard front thrust collar PTFE 9 Inboard rear thrust collar High purity alumina ceramic 10 Outboard rear thrust collar PTFE (w / filler) PTFE 11 Gasket PTFE 12 Support High temperature versions only ( and 2158) SiC 5
8 4 Handling Instructions 1. Do not operate the pump dry The sliding parts used in the MDM series pump are lubricated and cooled by the fluid being pumped. Never intentionally operate the pump dry or with the valves on the suction side closed. Otherwise, the inside of the pump will be damaged. Some MDM models are designed to tolerate brief or intermittent dry run operation, they are identified by the "CF" bearing system identifier in the model number. These models can tolerate dry run conditions for up to one hour. Longer dry run periods, or frequent dry running, may result in premature wear of the bushing and shaft. This can rapidly affect the standard clearances of the rotating elements inside the pump. If the pump is unavoidably or accidentally operated dry, with no obvious damage, allow the pump to cool down for a minimum of one hour before attempting to restart. Do not allow fluid to enter the pump cavity until the pump has cooled down. Sudden or rapid cooling of the pump may cause damage to the ceramic bushing system. A dry run monitoring device (current or power sensor) is recommended for the prevention of damage when dry run operation is likely. 2. Starting and Stopping Pay close attention to the following points to avoid water hammer upon starting and stopping of pump operation. Extra attention is required when the discharge piping is very long. Starting Prior to starting the pump, make sure that the power is turned off. Then carry out priming to fill the pump cavity with liquid. Caution! Manually rotate the pump drive shaft before start up to ensure ventilation of trapped air. Failure to do so may result in damage to the pump bearing system. Next, close the valves on the discharge side. Now you can turn the power on and start up the pump. When the pump has reached full speed and line pressure is stable, the discharge valve can be opened to the desired pressure setting. Caution! If the pump is operated with air remaining within the pump cavity, pitting, cracking, or breakage of the bushing and/or thrust collar may occur, causing damage to the pump. Stopping When stopping the pump, first close the discharge valve gradually. When it is completely closed, turn off the power switch so that the pump stops. Never stop the pump suddenly by quickly closing a valve (i.e., solenoid or hydraulic valves). 6
9 Caution! Quick valve closure may cause water hammer which can cause severe damage to the pump. 3. Maximum system pressure rating Max Allowable Working Pressure (MAWP) for MDM1516, 1518, 2156, 2526 and 326 is 150 psi (1.03 MPa). For MDM and 2158 MAWP is 250 psi (1.72 MPa) 4. Handling of slurry liquid In general, slurries should not be handled. However, a pump with a SiC bearing system, can handle slurries if the hardness is 80 Hs or below, with a standard maximum grain size of 2 MIL (50 microns) and the maximum density 5% wt. Slurries of higher concentrations may be possible with the use of slurry bearing design. Contact Iwaki America or your distributor for application review. 5. Influence of specific gravity on pump performance The performance of the MDM pump does not change when pumping fluids of high specific gravity. However, the effect of specific gravity on shaft power and magnet coupling torque requirements must be considered in the selection of the appropriate model for your application. 6. Influence of liquid viscosity on pump performance When pumping a high viscosity liquid, the discharge head and capacity of the pump may be lower than in the case of pure water. The required driving power may also vary and should be verified. 7. Intermittent operation Frequent start/stop switching shortens the service life of the pump. Limit the frequency of switching on or off to six times or less per hour. 8. Effects of temperature The pump itself may not suffer a change in performance due to temperature fluctuation. However, the liquid may change in terms of viscosity, vapor pressure, and corrosive properties. Pay special attention to changes in liquid characteristics as a result of temperature fluctuation. Refer to corrosion resistance tables for the recommended temperature range for various types of liquids. In case of any questions, contact Iwaki America or your distributor to determine if operation is feasible. 9. Separation of magnet coupling (decoupling) If the magnet coupling should disconnect, stop the pump immediately. If operation is continued, the torque rating of the coupling will be permanently reduced. 7
10 10. Operation within range of bell-shaped head/capacity curve In the case of a pump which generates a bell-shaped capacity curve in a low-flow range, do not operate the pump in the section where the line ascends. (Refer to the standard performance curve to verify the head/capacity). If the rightward ascending section of the head/capacity curve is part of the pump operation specifications, design the piping by observing the following points: 1. The discharge piping should have no water tank or air trap, 2. The discharge quantity must be adjusted by a valve which is installed close to the discharge port of the pump. 8
11 5 Installation, Piping, and Wiring Installation Position 1. Install the pump as close to the suction tank as possible (flooded suction). If the suction port of the pump is positioned higher than the suction tank (suction lift), be sure to arrange a foot valve in the suction pipe. The lifting capability depends upon the liquid properties, temperature, and length of suction piping. For details, consult Iwaki America or your distributor. 2. The pump can be installed indoors or outdoors. However, there should be sufficient space around the pump to enable efficient and easy maintenance. Installation 1. The pump anchoring area must be greater than the area of the pump baseplate. If the anchoring area is not large enough, the baseplate may be damaged due to the concentration of loads placed on it. 2. Set the pump baseplate on a concrete foundation and fasten the anchor bolts tightly to prevent the pump from vibrating during operation. A sturdy metal (or reinforced) skid or platform is also an acceptable mounting surface. 3. Insert a spacer between the concrete surface and the bottom of the base to level the pump horizontally. Next put a level on the discharge flange surface to adjust the pump horizontally in the direction of the pump shaft. Also adjust the direction vertical to the pump shaft at the same time by placing a level on the suction flange surface. Pour cement mortar into the anchor bolt holes after leveling has been completed. When the cement mortar is hardened, fasten the anchor bolt nuts firmly. (See Figure 3). Anchor bolt Base Spacer 4. In case there is influence of motor vibration during operation (e.g. sympathetic vibration with piping), an expansion joint should be provided between the pump and the piping before installation. Otherwise, pipes and gauges may be damaged. 9
12 Piping 1. Discharge pipe (use a support To keep the pump free from the load of the pipe) 2. Gate valve 3. Check valve 4. Pressure gauge 5. Motor 6. Pump Priming pump 8. Gate valve 9. Pump base 10. Compound gauge 11. Suction pipe (shortest horizontal section with an ascending gradient toward the pump) 12. Pipe support 13. Pump drain 14. Suction pipe 15. Suction pipe stabilizer brace (used if suction pipe is particularly long) 16. Foot valve D* or more inches or more D* or more (if sediment accumulates easily) 20. Suction tank 21. Screen 22. Short pipe * Pipe diameter Suction Piping Discharge Piping 9 Suction Piping 1. The suction pipe should employ the flooded suction method if possible. The shortest pipe possible, with the minimum number of bends, should be designed. Arrange a proper support on the suction pipe so that the load and the thermal stress of the pipe itself are not applied to the pump. 2. Attach the coupling on the suction pipe carefully, so that no air enters the line. The presence of air in the suction pipe may prevent priming of the pump. 3. Avoid installations with poor suction conditions (e.g. vacuum in suction tank, large suction head or long suction piping). NPSHa should always be at least 2 feet greater than NPSHr. For NPSHr values, refer to the standard performance curve for your pump model or contact Iwaki America or your distributor. 10
13 4. When using a bend on the suction side, install a straight pipe which is more than 20 inches long or 10 times as long as the suction port diameter before the suction port of the pump. Use the largest possible radius of curvature for the bend. 5. Do not allow any projection where air may be trapped along the suction pipe. The suction pipe should have an ascending gradient toward the pump. 6. If the diameters of the pump suction port and the suction pipe are different, use an eccentric reducer pipe. Connect the eccentric reducer pipe such that the upper part of it is level. Never use a suction pipe with a diameter smaller than that of the pump's suction port. 7. When using the flooded suction method, the suction pipe should be given a slight ascending gradient toward the pump so that no air pocket is created on the suction side. 8. The end of the suction pipe should be located 24 inches or more below the surface of the liquid. 9. A screen should be provided at the inlet of the suction tank to prevent the entrance of foreign matter into the suction pipe. Foreign matter may cause malfunctioning of and/or damage to the pump. The end of the suction pipe should be a least 1-1.5D from the bottom of the suction tank. (D=Diameter of suction pipe). 10. When employing the suction lift method, install a foot valve on the suction pipe. 11. When using the flooded suction method, it is recommended that a gate valve be installed on the suction pipe for easier overhaul inspection of the pump. Since this valve is used only in the overhaul inspection of the pump, keep it fully opened during normal pump operation. 12. Pay close attention to the lowest level of the liquid in the suction tank to avoid vortexing, air entrapment and associated suction piping concerns. The inflow pipe into the suction tank should be distanced from the suction pipe and positioned below the liquid surface as a means of preventing air entrapment to the suction pipe. If air bubbles are generated in the suction tank, install a baffle. 13. It is recommended that a vacuum/pressure gauge be installed on the suction piping approximately 6 pipe diameters from the pump suction port. 11
14 Discharge Piping 1. Use proper pipe supports so that the weight of the piping does not load the pump nozzle. 2. If a method other than flooded suction is used, install a special pipe for priming. 3. If the piping is very long, its diameter should be determined by calculating the piping resistance. Otherwise, the specified performance may not be obtained due to increased piping resistance. 4. A check valve should be installed if any of the following conditions exists in the piping: The discharge piping is very long. The discharge head is 50 feet or more. The end of the discharge pipe is located 30 feet higher than the surface of the suction tank. Several pumps are connected in parallel with the same piping. 12
15 5. The installation of a gate valve on the discharge pipe is recommended for the adjustment of discharge quantity and for the prevention of motor overload. When installing both a check valve and a gate valve, the check valve should be positioned between the pump and the gate valve. 6. A pressure gauge must be installed on the discharge piping, prior to the gate valve. 7. An air bleeding valve should be installed if the discharge pipe is very long in the horizontal direction. 8. A drain valve should be installed for the drainage of liquid if there is a chance that the liquid in the discharge pipe will freeze. Wiring POWER R S T OLR For ½ - 7½ HP POWER R S T MCB For HP OLR OLR MC MC OFF ON MC U V W M X Y Z PUSH BUTTON PBS OFF TR ON TR AR M PUSHBUTTON MCY AR MC MCY AR M MC ON OFF OLR MOTO ELECTROMAGNETIC PUSH OVERLOAD Figure 6 M ON OFF MC MC MC OLR TR AR MC Y TR AR MC MOTO PUSH ELECTROMAGNETIC NONFUSE ELECTROMAGNETIC OVERLOAD TIME AUXILIARY Use appropriate wiring materials, follow the instruction manual for the motor and abide by the local and national electrical codes. In addition, follow the instructions given below: 1. Use a motor contactor that conforms to the specifications (voltage, current, etc.) of the pump motor. 2. If the pump is installed outdoors, use waterproof wiring to protect the switches from rainwater and moisture. 13
16 3. The motor contactor and push button should be installed a reasonable distance from the pump. 4. For pumps using a motor of 10 HP or larger, use of a soft start motor voltage/amperage device is recommended. Refer to the wiring examples shown above. (These examples do not include the installation of a dry run prevention device. Follow the instruction manual of the dry run prevention device when installing it.) 6 Operation Notes on Operation 1. Never operate the pump with the suction valve (gate valve) closed. Otherwise, the internal bushing of the pump may be damaged. Refer to Handling Instructions regarding dry run designs. 2. In the event of cavitation, stop the pump immediately. 3. If the magnet coupling disconnects, stop the pump immediately. The torque rating of the magnet coupling will be reduced if operation is continued with the inner and outer magnets de-coupled. 4. Liquid temperature fluctuation should not exceed 144 o F (62 C) when starting, stopping, and operating the pump. 5. Be sure to partially close the discharge valve prior to start-up in order to prevent water hammer. 6. The pump should never be operated with the discharge valve fully closed for longer than one minute. A resulting rise in temperature of liquid within the pump may cause damage. 7. In the event of a service power failure, turn off the power switch immediately and partially close the discharge valve. 14
17 Start-Up Preparation When operating the pump for the first time after installation, and when restarting operation after a long interval, prepare for operation as described below. 1. Thoroughly clean the inside of the piping and pump. 2. Tighten the union fittings or flange connecting bolts and baseplate installation bolts. Check the torque of the bolts which couple the front casing and the bracket together. 3. Close the cocks of any pressure or vacuum gauges to prevent damage from sudden pressure changes. Open only when taking measurements. 4. Fully open the suction gate valve and partly open the discharge valve. Discharge valve may be adjusted after completion of priming and start-up process. 5. Use a screwdriver to rotate the motor fan and check that the fan rotates smoothly. This also purges any residual air from in and around the impeller, ensuring ventilation of entrapped air in pump casing. Failure to do so may result in damage to pump bearing system. 6. If using flooded suction, measure the pressure in the suction pipe to verify that the pump is filled with liquid. In the case of the suction lift method, simultaneously carry out priming and rotate the motor fan using a screwdriver to rotate the pump and remove any air trapped in the impeller section. 7. Run the motor momentarily to check the direction of motor rotation. The motor should run in the direction indicated by the arrow cast on the pump casing. If the direction is reversed, exchange two wires of the three-phase power wires. Note: All Iwaki America MDM series pumps rotate counter-clockwise when looking at the suction port of the pump. From the motor fan side, this would be viewed as clockwise. 15
18 Starting Operation Steps Pump operation is detailed below. 1. Verify valve position Operation Step 2. Check that the pump is filled with liquid. 3. Turn motor switch ON momentarily to check for correct direction of pump rotation Flow rate adjustment: Once total discharge pressure is increased to close to shut off pressure, open discharge valve gradually to set discharge pressure to desired specification. Notes Suction valve should be fully open, discharge valve closed. If the pump is not full of liquid, fill it according to steps 5 & 6 of Startup Preparation. Note the arrow direction on the casing to confirm the direction of rotation (clockwise when viewed from the motor fan side). Open valve slowly, paying attention to the motor ammeter to prevent it from being overloaded through excessive opening of the valve. Pump should be operated at a minimum flow rate of: Models MDM1516, GPM (20 LPM) Models MDM1518-2, 2156, 2158, 2526, GPM (50 LPM) In case of automatic control, partially close discharge valve when starting pump and gradually open the discharge valve thereafter. Do not operate the pump with the discharge valve closed for more than one minute. Points to be observed during operation: If the pump enters continuous operation condition, check flow meter and confirm that pump operation meets specifications. If flow meter is unavailable, check values of discharge pressure, suction pressure and current in relation to piping resistance. 16
19 Stopping Operation Steps Operation Step Notes 1. Close discharge valve gradually. 2. Stop motor. Caution! Do not cause sudden closure by using solenoid valve, etc. Pump may be damaged by water hammer. Observe that the motor stops rotating slowly and smoothly. If not, check inside of pump. Points to be observed when stopping: If pump operation is stopped in cold weather, liquid inside the pump cavity may freeze and damage the pump. Be sure to drain liquid completely. In case of short term shut down, which does not allow removal of liquid, use band heater to prevent liquid from freezing. In case of service power failure, turn power switch OFF and close discharge valve. 7 Maintenance and Inspection Daily Inspection 1. Check that the pump operates smoothly, without generating abnormal sounds or vibration. 2. Check the level of the liquid in the suction tank, and the suction pressure. 3. Compare the discharge pressure and current measured during operation with the specifications indicated on the motor and pump nameplates to verify normal pump load. Note that the indicated value of the pressure gauge varies in proportion to the specific gravity of the liquid. Note: The valve of the pressure gauge or vacuum gauge should be opened only when measurements are recorded. It must be closed after completion of each measurement. If the valve remains open during operation, the gauge mechanism may be affected by abnormal pressure caused by water hammer. 4. If a spare pump is included in the installation, keep it ready for use by operating it from time to time. 17
20 Periodic Inspection 1. To ensure efficient, smooth operation of the pump, carry out periodic inspection by following the procedure described below. Inspection records should be maintained. 2. When carrying out an overhaul inspection, handle the internal bushings and plastic components most carefully. Since the outer drive magnet and inner magnet capsule are very powerful, handle these components with caution. Take care not to trap hands and fingers between the magnets and metal objects. Also avoid positioning the magnets near any electronic device that could be affected by a strong magnetic field (i.e.. ATM cards or computer disks). Inspection Interval Part Inspection Points Operator Action Check for scoring Contact distributor if any abnormality is found. Every 6 months Outer magnet assembly Is magnet mounted normally? Is hexagonal socket set screw loose? Reinstall magnet on motor shaft and fasten hexagonal socket set screws. Is inner perimeter of magnet & motor shaft concentric? Check for scoring on inner diameter. Re-tighten or replace hexagonal socket set screws. Contact distributor is abnormality is observed. Every 3 months Containment shell Are there any cracks in liquidcontaining section? Wear of thrust collar? Stain in containment shell? Is there scoring? Replace if abnormality is observed. Replace if abnormality is observed Clean. Contact your distributor if abnormality is observed. Containment shell cover Improper installation in frame? Adjust. 18
21 Inspection Interval Every 3 months Part Inspection Points Operator Action Inner magnet assy Is there scoring on rear face or cylindrical body? Contact distributor if any abnormality is observed. Are there any cracks in the plastic of the rear section or cylindrical body? Bushing wear. Impeller Are there any cracks? Are there any cavitation marks? Stain or clogging inside impeller? Dimensional change of impeller? Contact distributor if any abnormality is observed Replace if abnormality is observed. (See Tolerance chart) Replace if abnormality is observed. Eliminate cause. Clean. Replace if abnormality is observed. Every 3 months Front casing liner Stain in liquid-contacting section? Are there any cracks? Clean Replace if abnormality is observed. Wear or crack on inboard thrust collar? Contact distributor if abnormality is observed. Expansion or wear of o-ring? Replace if part is damaged. Scoring on inner surface? Shaft Are there any cracks? Wear on surface? Contact distributor if abnormality is observed. Replace if abnormality is observed. Replace if wear limit is exceeded. 19
22 Replacement Tolerance Chart Dimensions in inches (mm) Model MDM1516 MDM1518, , 2156, 2526 MDM2158, 326 (N)= New (W) = Worn N W N W N W (A) Bushing ID * (20) (21) (26) (27) (30) (31) (B) Shaft OD* (20) (19) (26) (25) (30) (29) (C) Thickness of outer thrust collar ** (8) (6) (8) (6) (9) (7) * If the difference between Bushing ID and shaft OD exceeds in (1mm), either the bushing or the shaft, whichever has greater wear, should be replaced regardless of the values in the above table. In case of a ceramic bushing type pump, the shaft and the bushing should be replaced simultaneously. Initial wear may appear in the sliding part in the first stages of operation. This should not be mistaken for an abnormal condition. ** The step between the surfaces of the inboard thrust collar and the impeller upon shipment is.079 in. (2mm). Replacing the inboard thrust collar is recommended when this step is reduced to zero (0) in. UPON SHIPMENT STEP in (2 mm) IMPELLER INBOARD THRUST COLLAR 20
23 8 Troubleshooting Problem Symptom on Pump Discharge valve open Discharge valve closed Liquid level drops immediately when priming Pressure gauge & vacuum gauge indicate zero Cause Insufficient priming Dry run operation Foot valve clogged with foreign matter Air enters thru suction pipe or gasket section Inspection & Correction Stop pump, feed priming liquid & restart Replace strainer Check whether valve seat is clogged Check that connection flange in suction piping is sealed airtight Check whether suction liquid level is abnormally low Stop pump & use a screwdriver to check for easy & smooth rotation of motor fan. Liquid is not pumped Liquid level drops if discharge valve is opened after starting operation Pressure & vacuum gauge needles swing but return to zero immediately Magnet coupling is disconnected (de-coupled) Measure current level to check for low reading Check for foreign matter inside pump cavity Check whether voltage level is normal Replace outer magnet and/or inner magnet assembly RPM of pump is insufficient Confirm fluid specific gravity & magnet rating, determine if S.G. exceeds magnet rating Check wiring & motor and fix as necessary Vacuum gauge indicates high value. Pump rotation is reversed Strainer is clogged with foreign matter & liquid passage is blocked. Air is trapped in suction pipe. Correct motor wiring Remove foreign matter in strainer. Inspect installation of suction pipe & modify as necessary. Vacuum gauge indicates abnormally high value. Inlet section of impeller unit is clogged with foreign matter. Partially disassemble unit & remove foreign matter. Discharge quantity is small. Needles of pressure & vacuum gauges indicate normal values. Pressure & vacuum gauges fluctuate. Air enters via suction pipe or gasket section. Discharge side of pump is clogged with foreign matter. Check flange gaskets of suction pipe & tighten. Remove foreign matter or scale inside of piping. Vacuum gauge reads high while pressure gauge indicates normal value. Pressure gauge reads high while vacuum gauge indicates normal value. Air pocket or resistance in suction pipe. Discharge piping section causing high resistance or actual head & loss of head is too high. Inspect suction piping installation & make corrective adjustments. Check actual head & piping loss of discharge pipe & take necessary measures. 21
24 Problem Discharge capacity is small Symptom on Pump Discharge valve Discharge valve closed open Pressure gauge reads low & vacuum gauge reads very low Pressure & vacuum gauges indicate low values Cause Rotating direction of pump/motor is reversed. Motor overheats Insufficient voltage Discharge capacity is suddenly lowered. Vacuum gauge reads high Overload Ambient temperature is high. Strainer is clogged with foreign matter Pump vibrates Foundation is inadequate. Anchor bolt is loose. Suction pipe is closed. Cavitation is caused. Wear or melting of pump bearing. Damaged inner magnet assembly or pump shaft. Fluctuating dynamic balance of outer magnet assembly. Impeller is in contact with inner magnet assembly anchoring section. Wear of motor bearing. Inspection & Correction Correct motor wiring to reverse rotation (clockwise when viewed from motor side) Check whether voltage & frequency levels are adequate. Check whether specific gravity & viscosity of liquid are above spec. Stop pump & use screwdriver to check whether motor fan rotates easily & smoothly. Improve air ventilation. Remove foreign matter. Repeat installation process again. Retighten bolt. Clean, eliminate cause of cavitation. Replace. Replace. Remove or replace. Remove or replace. Replace bearing or motor. 22
25 9 Parts Description and Exploded View No. Description Qty No. Description Qty 1 Casing cover Motor adapter 1 1 & 1.1 Casing cover w/pfa liner & Flat washer 2 1 front outboard thrust collar 1.1 Casing liner w/front outboard Flat washer (PFA only) 2 1 thrust collar 2 Impeller Split washer 2 6 Shaft Split washer (PFA only) 2 19 Frame Split washer 6 or 8 72 Front inboard thrust collar Casing gasket Split washer Drain gasket Split washer Air vent gasket (PFA only) Eye bolt Drain plate Hex head bolt Air vent plate (PFA only) Hex head bolt (PFA only) Support Hex head bolt 6 or Magnet capsule Hex head bolt Containment shell Hex head bolt Containment shell cover Hex socket cap bolt Containment shell support Hex socket cap bolt Outer magnet assembly Hex socket set screw Bearing Impeller pin Rear thrust collar, outboard Rear thrust collar, inboard 1 23
26 10 Disassembly and Assembly of Pump Caution! Since the magnets used in the pump are powerful, be careful not to catch your fingers or hand between them during disassembly or assembly. Also, keep the magnet unit away from any electronic device that could be affected by a strong magnetic field. Prior to servicing, the suction and discharge valves must be closed. The piping and the pump often retain some liquid. It is recommended the piping and pump cavity be drained prior to servicing. If dangerous liquid is used, wear protection and flush pump with clean water or decontaminate prior to service. Make sure power to motor is OFF. Disassembly 1. Remove the drain hex bolts and flange covers, (in case of PFA type vent cover as well - (122.1)) to discharge the liquid from the pump. Flush the inside of the pump with a neutralizing fluid. 2. Remove the hex head bolts (901.5) to separate frame (19) from front pump liquid end. Take care to pull casing straight forward to prevent drive magnet (232) from damaging the rear casing cover (159) Note: Frame may also be removed by use of two jack screws ½-13 UNC x 4 (½-13 UNC x 2 for MDM 1516) from motor side of pump. Thread two bolts through frame, one on each side of casing. Alternate from side to side to jack front casing off frame evenly. 3. Remove hex bolts (901.4) of casing cover (1 or 1.1 for PFA) to remove containment shell support (231.2). 24
27 5. Remove containment shell cover (231.1) and containment shell (231) from liquid end assembly. If casing is difficult to remove rotate slightly as you pull it from the front casing. Take care not to drop the impeller (2) and inner magnet (230) assembly as they will come out with the containment shell and pump shaft (6). 5. Remove the outer magnet assembly. MDM MDM326 models (No motor adapter on MDM HP models) Remove the outer magnet by separating the motor from the frame (330.1 / 19). Stand the motor upright and remove the two M4 hex head socket set screws. Apply a pry bar to the boss of the outer magnet assembly and pull or lever the unit upwards. Store the outer magnet assembly in a proper place so that no metal pieces, etc. are attracted to it. Caution! Do not strike the outer magnet assembly. Direct impact may loosen the magnet strips or damage the motor bearings. Replacement of rear thrust collar, radial bearing, impeller. Bushing: 1. Stand up two weld tabs on rear thrust collar (314.1) using plastic welder or industrial dryer. Then using a hand (arbor) press, and jig (34 mm dia. x 100 mm length, 24 mm dia. x 80 mm length for MDM1516), remove the bushing (237) by pressing the replacement jig on it from the impeller side and remove the rear inboard thrust collar (314.2). 25
28 2. Remove impeller pins (942) from upper part of inner magnet by pressing pins in from the outside using a screwdriver or similar tool. Note: H version has welded impeller and magnet capsule. Entire unit will need to be replaced. 3. Remove impeller (2) from the inner magnet. If it is difficult to separate the two pieces softly strike the back shroud of the impeller while securing the inner magnet. Front Inboard Thrust Collar 1. Heat two sections of the impeller locking tabs for the inboard thrust collar using a hot gas welding machine or industrial dryer at F ( C). Remove the front inboard thrust collar (72) with a flat tip screwdriver by lifting upwards. Be sure not to exceed the recommended temperature. Excessively high temperature may result in deformation of the impeller and/or inboard thrust collar. 2. Place a new front inboard thrust collar into the impeller by aligning the recessed areas of the thrust collar with the mating surfaces of the impeller and press securely into place. Ensure that the thrust collar is completely seated against the recess in the impeller. 3. Secure the inboard thrust collar utilizing the two sections of the impeller locking tabs. Heat the locking tabs at the same temperature as that of the welding rod for secure welding. Ensure that the welding points are lower than the surface of the thrust collar. 26
29 Shaft 1. The shaft (6) is slightly pressed into the containment shell (231). Pay attention to the following point when replacing the shaft. If the shaft does not come off easily, warm the containment shell in hot water about 194 F (90 C) before pulling it out for replacement. 2. Holding the worn shaft in one hand and containment shell in the other, rock the shaft slightly as you pull them apart. If it is difficult to separate the parts by hand hold onto shaft and lightly tap the perimeter of the containment shell evenly with a resin hammer. Slowly withdraw the shaft while tapping. Never strike the shaft or the seal surface of the containment shell. 3. Clean any foreign matter or build-up on the containment shell. Align and insert the shaft into the containment shell by hand. Use a hand press if shaft is difficult to insert into the containment shell. Front Casing Liner: 1. Remove the drain (122.1) and vent (122.2 (PFA Type only)) flange covers. 2. Remove the five hex socket head bolts (903.1). 3. Detach the front casing cover halves (1) from casing liner (1.1). If this is difficult due to corrosion or rust on the covers, use a resin hammer and gently tap the edge of the casing covers. Never strike the shaft or the seal surface of the rear casing 4. Align and install a new front casing liner into covers. If the front casing liner is difficult to attach, tap the covers gently with a resin hammer until machined surfaces are tight around casing liner. 5. Secure all hex socket bolts tightly (refer to torque table for tightening Specifications). 6. Insert gasket (73.2) into the drain and drain plate covers (122.1) prior to installing them. Tighten vent and drain cover hex bolts. 27
30 Reassembly Reassemble the pump by reversing the order of disassembly. Refer to the exploded view diagram on page 24 for parts and locations. Pay attention to the following points: Replacement of gasket When reassembling pump, always replace the gaskets. In addition, confirm that the gaskets are not twisted or pinched by another part. The sealing section should be cleaned free of dust or scratches before installation. Fastening of bolts Fasten the casing cover bolts in a diagonal order, applying an equal torque to each MDM Model 1518,1518-2,2156, 2158, 2526, 326 Type Hex head bolt for casing cover Hex head bolt for ALL drain/vent Note: MDM and 2158 use 5/8 11 x 1¾ bolts. Fastening Torque Nm Kgf/m Lbf/in Use the following table for correct placement of the drive magnet. Size of Bolt ½-13 x 1½ ½-13 x 1¾ /16 18 x ¾ HP ID Mark H Size in 2 DN DN DN DN7/ DNIS/ISS DN ID Mark H Motor or motor adapter 1. Mount and bolt the motor adapter (330.1) to the motor. (Check orientation/label) 2. Mount and secure the outer magnet (232) to the motor shaft. (See drawing above) *Note: Use Loctite 242 (threadlocker) and torque the set screws (908.1) to 8.7 ftlbs. Confirm that there are no metal pieces or other matter adhering to the outer magnet. 28
31 3. Place new gasket (73.1) into assembled front casing/liner. Make sure surfaces are clean and free from foreign material. 4. Align and attach the impeller (2) with front inboard thrust collar (72) onto the inner magnet (230). Ensure that the impeller has bottomed within the inner magnet assembly and the impeller securing ports are aligned. Insert impeller pins (942). Use needle nose pliers to correctly position pins in impeller and inner magnet assembly. 5. Heat the inner magnet/impeller assembly in warm water or oven to 194 F (90 C) Place the assembly impeller side down on arbor press and insert bearing using replacement jig. Insert inboard thrust collar and using plastic welder or industrial dryer to weld heat tabs and secure collar in place. Note: Impeller and magnet capsule are welded together on high temperature versions. 6. Clean any foreign matter or build-up on the containment shell. Align and insert the shaft into the containment shell by hand. Use a hand press if shaft is difficult to insert into the containment shell. 7. Confirm that there are no metal pieces or other matter adhering to the inner magnet. Insert the inner magnet with impeller slowly into the containment shell. 29
32 8. Place impeller/inner magnet assembly onto the shaft in the containment shell (158). Align front of shaft with support in front casing liner and slowly rotate containment shell while pushing the two assemblies together. 9. Mount the containment shell cover (159) on the containment shell and place rear casing support (161). Secure casing support by tightening hex bolts (901.4) in diagonal pattern (refer to torque table). 10. Insert liquid end assembly into frame taking care to align it such that drive magnet does not contact rear casing. Use jack bolts (threaded about half-way through frame) to ease two assemblies together. Caution! The magnetic force is very strong. Ensure that your fingers or hands do not get caught between the liquid end assembly and frame. 11. Fasten the hex socket bolts (901.5) in a diagonal order applying equal torque to each (refer to torque table). 30
33 11 Spare Parts Appropriate spare parts are necessary to ensure continued pump operation. Expendable parts, such as bushings, shaft and outer thrust collar, should always be kept on hand. When placing orders, supply the following information. 1. Description and item number (according to this instruction manual). 2. Pump model number and serial number (as shown on the nameplate of the pump). 3. Drawing number if you have received a certified drawing Front Inboard thrust collar Outboard rear thrust collar Inboard rear thrust collar
34 12 Dimensions MDM1516 to 2526, 2-5 HP MDM1516 to Dimensions in inches (mm) *Meet ANSI B73.3M dimensional standards Model HP/Frame HC D 2E1 2E2 A Q P G H H1 O X Y 1516* 145TC 182TC (522.7) 29.0 (736.6) 5.25 (133) 5.25 (133) 5.98 (151.9) 5.98 (151.9) 9.45 (240.3) 9.45 (240.3) (290) 7.87 (199.9) 9.25 (234.9) (357.9) 7.25 (184.2) 7.25 (184.2) 0.63 (16) 0.63 (16) 0.63 (16) 0.63 (16) (298.7) (298.7) 6.5 (165.1) 6.5 (165.1) 4.0 (101.6) 4.0 (101.6) Weight w/o Motor (lbs) * 184TC TC 30.0 (762) 33.5 (850.9) 5.25 (133.3) 5.25 (133.3) 5.98 (151.9) 5.98 (151.9) 9.45 (240.3) 7.87 (199.9) 7.87 (199.9) (357.9) (357.4) 7.25 (184.2) 4.09 (103.9) 0.63 (16) 0.63 (16) 0.63 (16) 0.63 (16) (298.7) (298.7) 6.5 (165.1) 6.5 (165.1) 4.0 (101.6) 4.0 (101.6) TC 29.5 (749.3) 5.25 (133.3) 6.0 (152.4) 8.66 (219.9) (367.3) 4.09 (103.9) 0.55 (13.9) (298.7) 6.5 (165.1) 4.0 (101.6) * TC 33.5 (850.9) 6.25 (158.7) 6.0 (152.4) 9.84 (249.9) (380.2) 4.09 (103.9) 0.55 (13.9) (323.8) 6.5 (165.1) 4.0 (101.6) TSC (948.7) 7.00 (177.8) 6.0 (152.4) 9.84 (249.9) (380.2) 4.09 (103.9) 0.75 (19) 0.55 (13.9) (342.9) 6.5 (165.1) 4.0 (101.6) 154 For individual certified dimensional drawings, call Iwaki America or visit the Literature section on 32
35 MDM1518 to 326, HP MDM2156 to 326 Dimensions in inches (mm) *Meet ANSI B73.3M dimensional standards Model Frame HC D 2E1 2E2 A Q P G H H1 O X Y TC TC TC TC 284TC 184TC TC TC TC 29 (736.6) 31 (787.4) (726.9) (829.8) 36.5 (927.1) 29 (736.6) 31 (784.4) 31 (784.4) 36 (914.4) 7.09 (180) 7.09 (180) 7.00 (177.8) 7.00 (177.8) 7.00 (177.8) 7.09 (180) 7.09 (180) 8.25 (209.5) 8.25 (209.5) 8.66 (219.9) 8.66 (219.9) 8.66 (219.9) 8.66 (219.9) 8.66 (219.9) 8.66 (219.9) 8.66 (219.9) 9.76 (247.9) 9.76 (247.9) (279.9) (279.9) (279.9) (279.9) (279.9) (279.9) (279.9) (279.9) (299.9) (299.9) (347.5) (387) (509.8) (497) (514.8) (347.5) (367) (367.5) (380.2) 6.89 (175) 3.70 (93.9) 3.70 (93.9) 3.70 (93.9) 3.58 (90.9) 6.89 (175) 3.70 (93.98) 4.09 (103.9) 4.09 (103.9) 1.83 (46.5) 3.54 (89.9) 1.75 (44.4) 0.75 (19) 0.63 (16) 0.55 (13.9) 1.83 (46.5) 3.54 (89.9) 2.99 (75.9) 1.99 (50.5) 0.38 (9.6) 0.55 (13.9) 0.63 (16) 0.63 (16) 0.55 (13.9) 0.38 (9.6) 0.55 (13.9) 0.55 (13.9) 0.55 (13.9) 0.55 (13.9) 0.38 (9.6) (340.1) (340.1) (357.8) (357.8) (357.8) (340.1) (340.1) 16.5 (419.1) 16.5 (419.1) 6.3 (160) 6.3 (160) 7.09 (180) 7.09 (180) 7.09 (180) 6.3 (160) 6.3 (160) 8.25 (209.5) 8.25 (209.5) 3.15 (80) 3.15 (80) 3.15 (80) 3.15 (80) 3.15 (80) 3.15 (80) 3.15 (80) 4.0 (101.6) 4.0 (101.6) Weight w/o Motor (lbs) TSC (948.7) 8.25 (209.5) 9.76 (247.9) (299.9) (380.2) 4.09 (103.9) 1.25 (31.8) 0.63 (16) 16.5 (419.1) 8.25 (209.5) 4.0 (101.6) 144 For individual certified dimensional drawings, call Iwaki America or visit the Literature section on 33
36 Iwaki America Inc. 5 Boynton Road Hopping Brook Park Holliston MA USA TEL: FAX: Website:
IWAKI Magnetic Drive Pump MDM Series (ANSI) Instruction Manual
IWAKI Magnetic Drive Pump MDM Series (ANSI) Instruction Manual Read this manual before use of product Thank you for selecting IWAKI Magnetic Drive Pump MDM Series. This instruction manual, which is divided
Tri-Homo Style Operation and Maintenance Instructions
Tri-Homo Style Operation and Maintenance Instructions One Research Drive Stratford, CT 06615 (203) 375-0063 www.sonicmixing.com 1 Installation and Start-up Do not perform following adjustments without
BOWIE PUMPS OPERATION - MAINTENANCE
BOWIE PUMPS OPERATION - MAINTENANCE PUMPING PRINCIPLE: The meshing owieeof the gears cause a slight depression, with the resulting enmeshing of the gears causing a vacuum drawing the fluid being pumped
300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS
Section: MOYNO 500 PUMPS Page: 1 of 8 Date: March 1, 1998 SERVICE MANUAL MOYNO 500 PUMPS 300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS Mechanical Seal Models Packing Gland Models MODELS DESIGN FEATURES
INSTALLATION & OPERATING INSTRUCTIONS
INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.
STEERING HANDLEBAR/FRONT WHEEL/ FRONT SHOCK ABSORBER
14 14 STEERING HANDLEBAR/FRONT WHEEL/ SCHEMATIC DRAWING ------------------------------------------------- 14-1 SERVICE INFORMATION------------------------------------------------ 14-2 TROUBLESHOOTING-----------------------------------------------------
CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.
CAST IRON THE BASICS 1. DO NOT LIFT ON YOUR OWN. 2. ONLY LIFT THE RADIATOR VERTICALLY. 3. DO NOT LIFT MORE THAN 8/10 SECTIONS AT ANY ONE TIME. 4. POSITION THE RADIATOR BEFORE FINAL ASSEMBLY. 5. THIS PRODUCT
Float and Thermostatic Traps Series H, C and X
Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT
IMPORTANT SAFETY NOTICE
IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds
Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET
Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4
OPERATION & MAINTENANCE MANUAL. for VERTICAL INLINE PUMPS
OPERATION & MAINTENANCE MANUAL for VERTICAL INLINE PUMPS PATTERSON PUMP COMPANY A SUBSIDIARY OF THE GORMAN-RUPP COMPANY PO Box 790 9201 Ayersville Road Toccoa, Georgia 30577 Telephone: 706-886-2101 SAFETY
Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors
Char-Lynn Spool Valve Hydraulic Motors Repair Information W Series Geroler Motors with Parking Brake 004 Nut Key Ring, Retaining Bearing Ring, Retaining Ring, Retaining Washer (Thick), Pressure Washer,
DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT
3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT Instruction D10386 August 2013 Instructions These instructions provide installation, operation and maintenance information for BAW Butterfly Valves.
Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW
Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...
Lenntech. 1000 psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503
1 User s Guide to: Phoenix Vessel Technology Limited 1000 psi End port pressure vessels 2.5. Model number: 1503 Lenntech [email protected] Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 Phoenix
Char-Lynn Hydraulic Motor. Repair Information. 10 000 Series. October, 1997
Char-Lynn Hydraulic Motor October, 1997 Repair Information Geroler Motor Two Speed 001 27 Retainer inside bore of valve plate bearingless motors only 4 15 16 3 6 35 Parts Drawing 25 2 2 1 19 17 36 40 47
SureSite Magnetic Liquid Level Indicator
SureSite Magnetic Liquid Level Indicator Instruction Bulletin No. 177664-1 (Rev. E) Section 1: Weldments Thank you for purchasing the GEMS SureSite Magnetic Level Indicator. Please read this document prior
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19
Table of Contents Overview 1 Pump Disassembly 2 Control Disassembly / Reassembly 7 Pump Reassembly 13 Adjustment Procedures DR Control 19 Adjustment Procedures DRG Control 20 Adjustment Procedures DFR
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will
Installation Instructions 4508 4508S
SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
Owner s Manual. Models: 2S5P & 3S5P OPERATION AND MAINTENANCE OF SELF-PRIMING CENTRIFUGAL TRASH PUMPS PEDESTAL DRIVE
Owner s Manual Models: 2S5P & 3S5P OPERATION AND MAINTENANCE OF SELF-PRIMING CENTRIFUGAL TRASH PUMPS PEDESTAL DRIVE WARNING!! Installation & Operating Instructions Self-Priming Centrifugal Pump DO NOT
Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)
47 Brakes - Hydraulic Components (Page GR-47) FS III front brake calipers, servicing Front brake caliper piston, removing and installing FN 3 front brake calipers, servicing Front caliper piston, removing
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
Installation, Operating and Maintenance Instructions for AEON Metal Seated Gate Valve (MSGV) Water
1 Foreword 1.1 Thank you for choosing one of the range of AEON's BS standard valves. For safety purposes, the user shall read this instruction to fully understand the operation of the product. 2 AEON Design
STEERING SYSTEM - POWER
STEERING SYSTEM - POWER 1990 Nissan 240SX 1990 STEERING Nissan - Power Rack & Pinion Axxess, Maxima, Pulsar NX, Sentra, Stanza, 240SX, 300ZX DESCRIPTION The power steering system consists of a rack and
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
Rebuild Instructions for 70001 and 70010 Transmission
Rebuild Instructions for 70001 and 70010 Transmission Brinn, Incorporated 1615 Tech Drive Bay City, MI 48706 Telephone 989.686.8920 Fax 989.686.6520 www.brinninc.com Notice Read all instructions before
Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)
17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning
2" & 3" Poly Wet Seal Pump Instruction Manual
Always place the pump as close to the liquid to be pumped as possible. Keep the suction line short and with few bends. Keep the pump and engine on a level foundation. A poor foundation and a heavy suction
Cooling system components, removing and installing
Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,
1.8 CRANKSHAFT OIL SEALS
SERIES 60 SERVICE MANUAL 1.8 CRANKSHAFT OIL SEALS An oil seal is fitted between each end of the crankshaft and the bores of the flywheel housing and gear case cover to retain the lubricating oil in the
IF IT FLOWS THE BOWIE PUMP CAN PUMP IT
IF IT FLOWS THE BOWIE PUMP CAN PUMP IT Bowie Industries, Inc. Bowie, TX 76230 USA Page 1 Bowie Pumps Manual General Pump Information..Page 2 300 Series Pumps.. Page 5 400 Series Pumps.Page 11 500 Series
Service Manual Rol-Lift
R 2000 Service Manual Rol-Lift Series: T and E Developed by Generic Parts Service This manual is intended for basic service and maintenance of the Rol-Lift pallet jack. The pallet jacks you are servicing
Unit: mm(in) Item Standard value Service limit Axle shaft run out - 0.2(0.008)
Rear Wheel/Brake/Suspension 13. Rear Wheel/Brake/Suspension Service Information 13-1 Troubleshooting 13-2 Rear Wheel 13-3 Rear Cushion 13-4 Rear Swing Arm 13-7 Service Information General Safety If the
Stainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
1000-LB. TRAILER JACK OWNER S MANUAL
1000-LB. TRAILER JACK OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious
Machine needle shut-off nozzle type HP
Machine needle shut-off nozzle type HP pneumatically or hydraulically controlled Index of contents Chapter Page Safety instructions... 2 Installation instructions... 3 - Installation steps... 3 Initial
LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions
LORTONE LU6X-130 Item # 061-092 LU6X Basic Item # 061-090 LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions Introduction The LU6X is one the most versatile pieces of equipment
Spicer Axles & Brakes ABIB-0302
Information Bulletin Bulletin Type: Parts / Service Information Topic: Dana LMS Hub Assembly Procedure Steer and Drive Axles Spicer Axles & Brakes ABIB-0302 Note: Bulletin ABIB-0302 replaces the original
Trash Pumps Models: 56200, 562000, 56201, 562001, 56300, 563000, 56301, 563001
Trash Pumps Models: 56200, 562000, 56201, 562001, 56300, 563000, 56301, 563001 Specifically designed pumps for heavy duty applications Handles solids with eas and simple to open and clean Standard roll
BILLET HEADLAMP SHELL
-J008 REV. 007-07- BILLET HEADLAMP SHELL GENERAL Kit Number 770-0 Models For model fitment information, please see the P&A Retail Catalog or the Parts and Accessories section of www.harleydavidson.com
Trouble Shooting. Pump
Trouble Shooting Pump Trouble Possible Cause Remedy Oil leaking in the area of water pump crankshaft Worn crankshaft seal, bad bearing, grooved shaft, or failure of retainer o-ring. Excessive play on crankshaft
MODEL G300 BRAKE BLEEDER
MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY
11. COOLING SYSTEM 11-0 COOLING SYSTEM BET & WIN 50
11 COOLING SYSTEM SERVICE INFORMATION------------------------------------------------ 11-1 TROUBLESHOOTING----------------------------------------------------- 11-1 RADIATOR ------------------------------------------------------------------
GT Horizontal Split Casing Pumps
GT Horizontal Split Casing Pumps 302-054 Operations and Maintenance Manual SUPERSEDES: New EFFECTIVE: March 1, 2009 Plant ID No. 001-3930 SAFETY REQUIREMENTS These operating instructions must be complied
FRONT BUMPER INSTALLATION INSTRUCTIONS 2007-2011 DODGE / MERCEDES SPRINTER
Aluminess Products Inc 9402 Wheatlands Ct. #A Santee, CA 92071 619-449-9930 FRONT BUMPER INSTALLATION INSTRUCTIONS 2007-2011 DODGE / MERCEDES SPRINTER Please read before beginning Stainless steel hardware
Horizontal Jet Pumps 1/3-1-1/2 HP
Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The
Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)
19 Engine - Cooling System (Page GR-19) Cooling system draining and filling general information Body components, layout Engine components, layout Radiator fan run-on checking Recommended mixture ratios
Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)
17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure
Front brakes (FN- 3), servicing
j a t Front brakes (FN- 3), servicing 46-1 Front brakes, servicing Note: Install complete repair kit. After replacing brake pads and before moving vehicle, depress brake pedal several times firmly to properly
FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions
FJ2 2 Ton Trolley Floor Jack Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.
10 TON HYDRAULIC PRESS
10 TON HYDRAULIC PRESS Model Nos. CSA10F and CSA10B OPERATING & MAINTENANCE INSTRUCTIONS 0200 SPARE PARTS and SERVICING Please contact your nearest dealer, or CLARKE International, on one of the following
Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE
IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA
IWAKI MAGNETIC DRIVE PUMPS Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA Magnetic drive process pump resistant to dry run damage The Series of Magnetic drive process pumps have wetted parts made of fluororesin.
Cooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
Trunnion-Design Ball Valves
Trunnion-Design Ball Valves 12" 20" (DN 300 500) Series 7150 12" (DN 300) Series 730S 12" 20" (DN 300 500) Series 7300 14" 24" (DN 350 600) Series 9150 14" 24" (DN 350 600) Series 9300 Installation, Maintenance
SINGLE STAGE INLINE FIRE PUMP
MODEL 383 SINGLE STAGE INLINE FIRE PUMP INSTRUCTION AND REPAIR MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains
STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13
STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13 (See Supplemental Instructions for trailers with heavy duty round footplates and/or Power Leveling Systems) PHONE SUPPORT
ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions
4057250/8 IM-P405-16 AB Issue 8 ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Operation
! WARNING. Before using product, read and understand instructions.
McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes
P7100 PUMP INSTALLATION INSTRUCTIONS Diesel Care & Performance Inc
P7100 PUMP INSTALLATION INSTRUCTIONS Diesel Care & Performance Inc Installation Timing Pin Location CAUTION: Before installing the injection pump, be sure that number 1 cylinder is at the Top Dead Center
2008 ACCORD - Front Knuckle/Hub/Wheel Bearing Replacement (page 18-13)
2008 ACCORD - Front Knuckle/Hub/Wheel Bearing Replacement (page 18-13) Exploded View Special Tools Required Ball joint remover, 28 mm 07MAC-SL0A202 Hub dis/assembly tool 07GAF-SD40100 Bearing driver attachment,
GATE VALVES ASAHI AV VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1
Serial No. H-V011-E-11 GATE VALVES Type P (Standard: Plug) Type S (Soft Seal) Contents (1) Be sure to read the following warranty clauses of our product 1 User s Manual (2) General operating instructions
ARTICLE BEGINNING APPLICATION IDENTIFICATION DESCRIPTION LUBRICATION & ADJUSTMENT TROUBLE SHOOTING. MANUAL TRANSMISSIONS Saab 5-Speed Transaxle
Article Text ARTICLE BEGINNING MANUAL TRANSMISSIONS Saab 5-Speed Transaxle APPLICATION TRANSMISSION APPLICATION ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ Vehicle Application Transmission
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 [email protected] www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS
Installation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com INTRODUCTION The purpose of this manual is to assist you in the assembly, operation and maintenance of your sprayer
V47 Series Temperature Actuated Modulating Water Valves
V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate
STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES
GATE VALVE O.S. & Y 1.0 Periodic Inspections 1.1 The valve stem packing should be inspected at least monthly. If the stem packing shows signs of leakage, simply tighten the adjusting nuts to compress the
Round Housing with Side Ports
Power Steering Steering Control Unit (SCU) Parts and Repair Information 5 Series Steering Control Units 001 Square Housing with Side Ports Round Housing with Side Ports T E L RP Round Housing with End
TECHNICAL SERVICE MANUAL
Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com TECHNICAL SERVICE MANUAL MAGNETIC DRIVE - CAST IRON & DUCTILE IRON PUMPS SERIES SG & SGN SIZES
IWAKI MAGNETIC DRIVE PUMPS MDM. Patent & Pat.Pend. JAPAN / U.S.A. / EU / CHINA / TAIWAN
IWAKI MAGNETIC DRIVE PUMPS Patent & Pat.Pend. JAPAN / U.S.A. / EU / CHINA / TAIWAN Magnetic drive process pump resistant to dry run damage The Series of Magnetic drive process pumps have wetted parts made
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
TYPE E Main Valve Sizes 3 /8 through 12
SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,
SELF-STEERING AXLE TABLE OF CONTENTS
SELF-STEERING AXLE TABLE OF CONTENTS Section 1 - Introduction Section 2 - Pre-Installation Check List Section 3 - Ride Height Adjustments Section 4 - Suspension Mount Section 5 - Axle Mount Section 6 -
2006 HEADSHOK Service Video #1
LEFTY SPEED DLR DAMPING CARTRIDGE This document explains how to properly remove, disassemble, inspect, reassemble and reinstall the Lefty Speed DLR2 damping cartridge. It is a document to be used in conjunction
DiscPlus DX195 and DX225 Air Disc Brakes
Revised 11-04 Technical Bulletin Revised 1 Technical 11-04 Bulletin DiscPlus DX195 and DX225 Air Disc Brakes Inspection, Installation and Diagnostics Air Disc Brake Inspection Intervals and Procedures
CHROME FRONT BRAKE MASTER CYLINDER KIT
-J075 REV. 009-0-0 CHROME FRONT BRAKE MASTER CYLINDER KIT GENERAL Kit Number 5-99D, 5-99D Models These Chrome Master Cylinder Kits are designed to replace the original equipment front brake master cylinder
IMPORTANT DOCUMENTATION DO NOT DISCARD!
PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance
Check for deteriorated, shifting or missing tie-down pads. Replace if needed.
C C 0 5 C H A S S I S F R A M E Chassis Frame Overview The Blue Bird Vision s chassis frame consists of two main C-channel rails which run the entire length of the bus, and several different kinds of cross
Rexroth Hydraulic Pump A10VO Series User Manual
Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html TECHNICAL SERVICE DEPARTMENT Removal, Cleaning, & Reinstallation of the Burner Assembly For models 74 & GT199 Required tools -
Drive shaft, servicing
Volkswagen Passat B6 - Drive shaft, servicing Стр. 1 из 41 40-7 Drive shaft, servicing Drive shafts, overview I - Assembly overview: Drive axle with CV joint VL100 40-7, Drive axle with CV joint VL100,
The Ford Model A Water Pump
The Ford Model A Water Pump George Washington Chapter, Inc. 3903 Old Lee Highway Fairfax, VA 22030 1 Table of Contents Introduction/Specifications.. 3 1. Water Pump Inspection and Removal. 4 a. Removal..
TECHNICAL SERVICE MANUAL
TECHNICAL SERVICE MANUAL HEAVY-DUTY PUMPS SERIES 4195 AND 495 SIZES GG - AL SECTION TSM 144 PAGE 1 of 10 ISSUE D CONTENTS Introduction....................... 1 Safety Information.................... 2
This is the civilian transfer case with the cooling loop only found in the driven gear half of the front case.
INTRODUCTION The Transfer case used in the AMG Hummer is a New Venture Gear, model 242. This case has been in use for the H-1/Hummer since the early 1990 s. There have been modifications to the internal
TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V
TITAN pt. no.: 02 0000 0143 Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS G e n e r a t i o n V Extended
POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT
POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric
AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller
January 2013 AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller Milliken Valve Company 190 Brodhead Avenue, Suite 100 Bethlehem, PA 18017 Phone: (610) 861-8803 Fax:
PRESSURE REDUCING CONTROL VALVE
Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line
AXLE SHAFTS - FRONT. 1993 Toyota Celica DESCRIPTION REMOVAL, DISASSEMBLY, REASSEMBLY & INSTALLATION. 1993 DRIVE AXLES Toyota FWD Axle Shafts
AXLE SHAFTS - FRONT 1993 Toyota Celica 1993 DRIVE AXLES Toyota FWD Axle Shafts Toyota; Celica DESCRIPTION Axle shafts transfer power from transaxle to driving wheels. All axle shafts consist of a shaft
Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation
Instruction Manual 1052 Size 20 Actuator (F & G) Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation Contents Introduction... 1 Scope of manual... 1 Description... 1 Specifications...
OPERATING AND MAINTENANCE INSTRUCTIONS PUMP TYPE 215.10
OPERATING AND MAINTENANCE INSTRUCTIONS PUMP TYPE 215.10 To Pump model Pump number Our order Your order Order date Reference Item number Destination Plant Before storing, installation, operation or maintenance
DODGE USAF 200/300 Direct Mount Pillow Block Bearings
DODGE USAF 200/300 Direct Mount Pillow Block Bearings These instructions must be read thoroughly before installation or operation. WARNING: To ensure that drive is not unexpectedly started, turn off and
Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks
TITAN pt. no.: 03 0000 0120 Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks INSTALLATION INSTRUCTIONS G e n e r a t i o n V Extended
