1 Modern Method to Determine Recovery Boiler Efficiency Authors*: Esa K. Vakkilainen 1 Pekka Ahtila 2 Keywords: Acceptance test, black liquor, boiler efficiency, energy balance, recovery boiler ABSTRACT Recovery boiler mass and energy balances are needed for the performance testing of recovery boilers, mill energy wide control systems, and in calculating the air emission data. Typically, recovery boiler balances are mainly based on 1996 TAPPI publication Performance Test Procedure: Sodium Base Recovery Units, the use of which is problematic in Europe because of its view that the losses from the recovery of process chemicals are counted when determining the recovery boiler steam generation efficiency. A low efficiency leads to taxation and legislative problems in some European countries. There is a newly accepted European standard for steam generator acceptance tests: EN :2003 Water-tube boilers and auxiliary installations - Part 15: Acceptance tests. This paper examines how the standard could be applied to recovery boilers to find out the net efficiency which is shown to be approximately the same as for other biomass boilers, not 10% lower. A new and more accurate method to calculate losses from convection and conduction is discussed. In addition, a suggestion on how to handle borate autocausticization in the recovery boiler furnace is made. INTRODUCTION Recovery boiler mass and energy balances are needed for the performance testing of recovery boilers, mill energy wide control systems and in calculating the air emission data. There is no suitable procedure for modern recovery boilers. Current recovery boiler balances are mainly based on 1996 TAPPI publication Performance Test Procedure: Sodium Base Recovery Units [1] the use of which is problematic in Europe because of US units and its view that the losses from the recovery of process chemicals are counted when determining the recovery boiler steam generation efficiency. General steam generator balances have been based on the outdated DIN 1942 Acceptance Test on Steam Generators [2], which fails to mention recovery boilers. There is a newly accepted European standard for steam generator acceptance tests: EN :2003 Water-tube boilers and auxiliary installations - Part 15: Acceptance tests [3]. This paper examines how the standard can be applied to recovery boilers. Because this standard does not give answers to kraft recovery boiler specific questions, some additional definitions have been made to e.g. calculate some heat losses. Borate autocausticization in the recovery boiler furnace has been included. This type of operation takes currently place in some Scandinavian mills. The balances are thus based on the as-fired liquor flow and as-fired liquor dry solids. The mass and energy balances are made for the unit mass flow of the as-fired liquor. BALANCE CALCULATIONS Recovery boiler mass and energy balances have been presented by Gullichsen [4], Clement et al. [5], Adams and Frederick [6], and Vakkilainen [7]. The conventions used to express the heat used in the reduction and the heat losses as smelt are for every author similar to the Tappi standard [1] that covers exclusively the recovery boiler mass and energy balance calculation. Boiler efficiency The boiler efficiency is a measure of the goodness of the chosen process and equipment to transfer the combustion heat to the heat in steam. For the best solid fuel boilers, the boiler efficiency is 86 90% [8]. Oil and natural gas fired boilers can achieve 90 94% efficiency. The boiler efficiency can be defined as the ratio of the useful heat output to the total energy input. η is the boiler efficiency Q abs is the useful heat absorbed (heat transferred to steam) is the heat and energy input into the boiler Q in 1 *Authors references: 1. Lappeenranta University of Technology, P.O. Box. 20, FI Lappeenranta, Finland 2. Aalto University, P.O. Box 4100, FIN-02015, Espoo, Finland s: [email protected], [email protected] Corresponding author: Esa K. Vakkilainen - [email protected] 58 Revista O Papel - dezembro/december 2011
2 To determine the efficiency of a boiler, a system must be defined and the energy flows that cross the system boundaries must be resolved. System boundaries should be chosen so that it is possible to define all the energy and mass flows in and out with sufficient accuracy. In practice, many minor flows are usually neglected. When determining the boiler efficiency, all internal reactions and recirculations can be neglected. The determination of boiler efficiency can be done with only flows through the system boundaries. In a simple boiler process, the fuel and the required amount of combustion air are fed into the boiler. The fuel reacts with the oxygen in the boiler and the flue gas is drawn out. The released heat is captured to the water pumped into the boiler which transforms it to the steam that flows from the boiler. It is clear that the system boundaries can be drawn in many ways. For example, the boiler house might form a convenient system boundary. It has been pointed out that the losses and heat input caused by fans, blowers and pumps should not affect the boiler efficiency. On the other hand, forced circulation pumps, flue gas recirculation fans and other internal process devices should be taken into account because they play a role when the boiler efficiencies between different types of boilers are compared. Therefore, the system boundary for the boiler efficiency loosely includes some but not all the equipment inside the boiler house. A system boundary for the boiler efficiency measurement is determined in an equivalent way to the definition in EN Figure 1 shows a typical system boundary for a recovery boiler. All flow values are recorded when the flow crosses the system boundary. Figure 1. Typical system boundaries for a recovery boiler Comments for system boundary definition Most of the important subsystems are inside the system boundary: black liquor preheating and the associated equipment that increase the heat input and all the equipment starting from the first heat transfer surface, air preheater, including all the steam and water heat exchangers that cool the flue gas as they remove heat from flue gas and transfer it to steam/water. If forced circulation pumps are used, they are inside the system boundary. Many important subsystems are outside the system boundary. Black liquor handling, storing and feeding equipment affect only the incoming black liquor properties. Air fans and air ducts affect the entering air temperature. Smelt handling and dissolving tank occur after the smelt exits the recovery boiler. Flue gas cleaning equipment affects the flue gas after it exits the boiler. A possible fan for flue gas affects the flue gas after it exits the boiler. The control system, instrumentation and electrification do not loose heat to the steam/water system. MATERIAL AND ENERGY BALANCE The control of combustion requires air flow that matches the fuel flow. The amount of air required to burn a mass unit of black liquor depends mainly on the water content and the heating value of the fuel. It is only the organics in black liquor that combust. A black liquor heating value increase, Figure 2, means that more air is needed for the combustion. Figures like Figure 2 can be used to estimate the required air flow for the dimensioning of the fans. More importantly, they should be used to estimate the possible range of air flows. A recovery boiler should be able to handle not only the design black liquor, but a range of typical black liquors. Normally, the actual design and performance estimation is done using the actual black liquor elemental composition. Typical biofuels consist of carbon, hydrogen, nitrogen, sulfur, and oxygen. Black liquor contains also a high amount of ash; sodium, potassium and chloride compounds. It is often impossible to define the individual chemical compounds that form the fuel. The stoichiometric air demand can be calculated assuming that the fuel can be divided into three fractions: i) organic portion, which combusts fully, ii) reactive inorganic portion, which reacts to predefined end products, iii) inactive portion, which passes through the combustion system unchanged. The basis for material calculations is typically one mass unit of black liquor. If mass balance values for one mass unit are known, it is easy to formulate the mass balance for a known load by multiplying all values with a single factor. Flue gas flow The black liquor flue gas production depends on the black liquor heating value. For a simple analysis, the estimation based on the predetermined mass ratio of flue gas to air can be done. The accurate flue gas flow can be calculated from a simple mass balance, if air flow, black liquor flow and smelt flow are known. When calculating real recovery boiler air and flue gas flows, the leakage should be taken into account. Air flow through air fans is less than the calculated dezembro/december Revista O Papel 59
3 Figure 2. Black liquor air demand as a function of the lower heating value as some of the air is infiltration air through various openings. The flue gas flow at stack can be significantly higher than through the economizers because of the same reason. Useful heat output The useful heat output includes all the heats to all of the steam flows. This value depends on the boiler type and the boundaries with which the boiler efficiency is calculated. Normally, the useful heat output can be defined as 2 Q ms is the heat transferred to main steam Q rh is the heat transferred to reheat steam Q bd is the heat transferred to blow down The steam used to heat air or sootblowing are not taken into account. Heat and energy input The energy input consists of two components. One is proportional to the fuel flow, and the other does not depend on the fuel flow. The energy flows that depend on the fuel flow are: - Chemical energy in the main fuel, H u (heat of combustion) - Chemical energy in the auxiliary fuels, H u (heat of combustion) - Energy included in the fuel preheating, Q f - Energy included in the air preheating, Q a Examples of energy flows that are somewhat independent of the fuel flow are shaft powers of the flue gas and air fans, shaft powers of circulation pumps, and the energy input by flue gas recirculation fan. It is customary to treat the useful heat input as a difference of input and output values. This means that the useful heat is the difference between the enthalpies of output flows and input flows. Therefore, it is logical that many energy flows are not considered as input flows. Such input flows include the heat in the feedwater, the heat in the desuperheating water flow and the heat in the incoming steam flow to the reheater. Problems in determining efficiency with the direct method Acceptance standard EN :2003 Water-tube boilers and auxiliary installations - Part 15: Acceptance tests states that the efficiency can be calculated with a direct method. When mass flows, specific heat values and temperatures are known, the heat input with preheated air and fuel can be calculated using e.g. the following simplified formula or with the states of the flows as : H u is the heating value of fuel m f is the fuel mass flow Q f is the heat transferred to preheated fuel Q a is the heat transferred to preheated air P is the sum of mechanical end electrical energy input flows m ms is the main steam mass flow m rh is the reheat steam mass flow m bd is the blow down mass flow m a is the air mass flow h ms is the enthalpy of main steam h fw is the enthalpy of feedwater steam h bd is the enthalpy of blowdown h rh,out is the outlet enthalpy of reheat steam h rh,in is the inlet enthalpy of reheat steam h f,out is the outlet enthalpy of fuel h f,in is the inlet enthalpy of fuel h a,out is the outlet enthalpy of air is the inlet enthalpy of air h ain Revista O Papel - dezembro/december 2011
4 The above presented formula is a very simple formula. It ignores most of the energy flows that cross the boundary. We note that at least the following streams, typical for the recovery boiler, have not been accounted for: NCG-flows, methanol, turpentine flows, condensate, leakage air, sootblowing, other electricity flows, flows to and from flue gas cleaning, atomizing steam, auxiliary fuels, and HVAC streams. It can be argued that these streams are minor and do not affect the calculation. It is difficult to assess their effect a priori without measuring them. Thus, the need to measure many flows is one of the main problems in the direct efficiency measurement. Another problem arises from the theory of mathematical uncertainty associated with the measurements. As each and every stream needs to be measured, the error in the efficiency becomes quickly very large. Therefore, the direct method is very seldom used in practice. the heat that can be released in the combustion of black liquor. Other large sources are the sensible heats in black liquor and air preheating. Useful heat The useful heat can be calculated by subtracting the sum of heat losses from the total heat input. The useful heat is the heat than can be used to generate steam and the heat that is used in reduction and autocausticizing reactions. Figure 4 shows how the total heat input is used. Most of the heat input is converted to steam. Reduction reactions are responsible for almost half of the rest. Autocausticizing with borate takes quite little heat. The biggest actual losses are the heat lost with wet flue gases and the sensible heat in smelt. Determining efficiency with the indirect method The recovery boiler efficiency is determined always using the indirect method. The efficiency equation can be arranged as 5 and even further as Q loss,i is the i:th heat lost The main losses in a recovery boiler steam generator are: the heat lost with the flue gases, the losses of unburned combustible fuel, the sensible heat in the smelt flow (ashes), and the radiation and conduction losses. Most of these losses can be estimated to a greater accuracy than the actual flows. The indirect method, therefore, gives a higher accuracy when estimating the efficiency of the steam generator. As one can see from Figure 3, most of the heat input comes from 6 Figure 4. Example heat outputs of a recovery boiler Heat for reduction A recovery boiler recovers heat from the combustion of organics in the black liquor. In addition, it converts inorganic materials from their oxidized state to the reduced state. All this is useful work and consumes usually about 10% of the heat input. It should be taken into account in the recovery boiler net efficiency. Q dr is the sum of heats to reduction 7 Example: In a 4000 tds/d recovery boiler burning softwood black liquor at 85% dry solids, the heat used in the reduction is 1818,7 kj/ kgds, the losses are 3382,9 kj/kg, and the heat input based on LHV is 1375,6 kj/kgds. Calculate the recovery boiler efficiency based on the heat in the incoming fuel 8 The steam generation efficiency is Figure 3. Example heat inputs to a recovery boiler 9 dezembro/december Revista O Papel 61
5 A modern recovery boiler is well in the range of the efficiencies of other biofuel boilers. RECOVERY BOILER SPECIFIC QUESTIONS IN BALANCE Using European standard EN :2003 Water-tube boilers and auxiliary installations - Part 15: Acceptance tests for recovery boiler balances, one needs to define some specific details: how to take into account NCG (DNCG and CNCG), the dissolving tank vent gases, the methanol and turpentine, and the ash pickup with evaporator liquor, and determine the radiation and convection losses. DNCG combustion in the balance The combustion of dilute non condensable gases (HVLC) in recovery boilers should be treated like introducing wet additional air, if not otherwise agreed upon. If DNCG burning is allowed, their sulphur content needs to be very low. These gases do not typically contain combustibles. The error in the efficiency is small. CNCG combustion in the balance The combustion of concentrated non condensable gases (LVHC) in recovery boilers should be treated like burning auxiliary fuel. In the performance test, the heating value and the analysis in the contract corrected to actual conditions (water content) can be used. Dissolving tank vent gas combustion in the balance The combustion of dissolving tank vent gas in recovery boilers should be treated like combustion of dilute non condensable gases. Heating value for dissolving tank vent gas is zero, and the analysis is a mixture of water vapor and dry air. Methanol and turpentine combustion in the balance The combustion of methanol and turpentine in recovery boilers should be treated like burning auxiliary fuel. In the performance test, the heating value and the analysis corrected to actual conditions (water content) can be used. Ash pickup with evaporator liquor The way boiler and ESP ash is mixed to the black liquor does not matter. The mixing tank is placed outside the boiler balance boundary. This way it does not matter for the boiler balance whether it has a modern ash pickup with evaporator liquor or a traditional ash mixing to incoming liquor. The ash from recovery boiler increases with the boiler load and black liquor dry solids. Figure 5 represents an estimate for ash flows from a modern recovery boiler. As the ash flow is notoriously difficult to measure, a figure of this kind can be agreed to show the ash flow during the balance case. Dust flow in Figure 5 is represented by the following equations q ESP = *ds-(2800-HHRR)/1000* ± 3 10 q ECO = 0.1*ds-4 ± 2 11 q BB = 1 ± 1 12 q ESP is the dust flow to electrostatic precipitator divided by dry flue gas flow at 3% O 2, g/m 3 n, dry q ECO is the dust flow from economizer hoppers divided by dry flue gas flow at 3% O 2, g/m 3 n, dry q BB is the dust flow from boiler bank hopper divided by dry flue gas flow at 3% O 2, g/m 3 n, dry ds is the as-fired black liquor dry solids, % HHRR is the heart heat release rate, kj/m 2 HHRR = LHV*MCR/A bottom 13 LHV is the as-fired black liquor dry solids lower heating value, kj/kgds MCR is the as-fired black liquor dry solids flow, kgds/s A bottom is the recovery boiler furnace bottom area, m 2 Sensible heat in black liquor It is recommended that no separate determination of the sensible heat of black liquor is done for the performance test. In the performance test, the contract value corrected to actual conditions Figure 5. Effect of black liquor dry solids to dust flows; BB ash is the lowest line, ECO ash next higher line, ESP ash the upper lines at different HHRR 62 Revista O Papel - dezembro/december 2011
6 (dry solids, temperature) can be used. If the contract has no specified values, then a value from reliable literature [9] can be used. Heat lost with the flue gases The biggest heat loss from a steam generator is the heat lost with the exiting flue gas. The flue gas loss depends on the final flue gas temperature and the amount of flue gases. Thus, the higher the air ratio the higher the flue gas losses. The flue gases should leave the boiler at a temperature as low as possible to minimize the flue gas losses. Usually, either economics, equipment or corrosion issues limit the flue gas temperature between 150ºC and 200ºC. Losses in the unburned combustibles The fuels fired into the boiler will not combust totally. Thermodynamics limits the combustion process to some finite value. This means e.g. that there is always some CO, H 2 and other hydrocarbons present in the flue gases. When burning biofuels, some carbon tends to remain unburned. This means that some carbon remains in the ash. Carbon in the ashes captured from the flue gases is mixed with black liquor. This means that no losses occur. Usually the carbon content in modern recovery boilers is extremely low. Some unburned carbon exits with the smelt. The heat lost with this stream is very low. Losses of sensible heat of smelt To know the loss in the sensible heat of smelt, the temperature, flow and enthalpy must be determined. The enthalpy of different smelt components (e.g. Na 2 S) can be expressed with the following equation: h c h m h c = h m + c p (T smelt - T ref ) 14 is the specific enthalpy of component, J/kg is the specific enthalpy of melting for component, J/kg c p is the specific heat capacity of component, J/kg ºC T smelt is the smelt temperature, ºC T ref is the reference temperature, ºC Borate There are some mills in Scandinavia that use borate autocausticization [11]. Borate compounds can be treated similarly to sulfur compounds. Loss in electrostatic precipitator ash The heat loss in ash is usually small enough that even high inaccuracies in the ash loss determination usually have a negligible effect on the accuracy of overall efficiency. RADIATION AND CONVECTION HEAT LOSSES There are some losses from the hot boiler walls to the surroundings. Part of this energy increases the incoming air temperature. The amount of heat recovery does not affect the boiler efficiency but affects the amount of heat needed for air preheat. Radiation and convection heat losses do not depend on the boiler load. Radiation and convection heat losses from the recovery boiler are hard to measure because there are many flows in and out to the space surrounding the boiler proper inside the recovery boiler building. The radiation and convection heat loss can be estimated through equation 16. The coefficient is between coal (0.022) and lignite (0.0315) boiler values [11]. This equation with Tappi loss function is presented graphically in Figure is the radiation and convection heat loss, MW is the useful heat output at MCR load, MW Most of the heat loss is from pipes (50%). Ducts and tanks account for only a minor portion (10%). The furnace accounts for roughly between fourth and fifth part (22%). Almost as large portion as furnace of heat losses comes from the electrical equipment (18%) [12]. The losses calculated from equation 16, the losses from Tappi and the measured losses are compared in Table 1. As can be seen, the Tappi loss function is not valid for boilers above 3500 tds/d. The enthalpy for a smelt with a given composition can then be calculated as 15 H smelt is the enthalpy of smelt, J m i is the mass of component i, kg is the specific enthalpy of component i, J/kg h c,i Specific heats of melting and specific heat capacities for typical smelt compounds can be found in literature [9, 10]. Figure 6. Radiation and convection losses: Equation 16, Tappi standard dezembro/december Revista O Papel 63
7 Table 1. Calculated heat losses compared to measured heat losses from Finnish recovery boilers [10] Boiler Capacity tds/d Calculated heat loss Tappi loss Measured kj/kgds kw kj/kgds kw Sunila SK Kaukopää, SK Rauma, SK Kaukas, SK BLACK LIQUOR HEATING VALUE AND ANALYSIS The determination of the black liquor heating value and the elemental analysis is typically done at an accredited laboratory. The analyzed heating value is always the higher heating value. In the literature, one sees also often the effective heating value in which the loss by heat of reduction has been subtracted from the lower heating value [4, 6, 9]. The black liquor higher and lower heating values in dry black liquor are related with the known equation 17 H is the hydrogen mass fraction in black liquor M i is the mole weight of i, kg/kmol Black liquor hydrogen to carbon ratio is practically constant and the black liquor higher heating value is a function of carbon content. Therefore, with a very good accuracy, the lower heating value of black liquor dry solids can be presented as a function of the higher heating value Typically, the lower heating value of dry black liquor is about 0.7 MJ/kgds less than the higher heating value. It should be noted that, generally, the analysis accuracy of heating value is 18 Figure 7. Black liquor higher heating value as function of lower heating value about 0.1 MJ/kgds. The correlation shown in equation 18 is valid for all kinds of black liquors, Figure 7. ERROR ANALYSIS Errors associated with the measuring equipment and analysis methods will affect the result of the performance test. All used measuring equipment should be calibrated before the performance test. If the result of an individual measurement has not been subjected to a closer error analysis, the error in the efficiency can be assumed to be according to Table 2. Table 2. Error in efficiency caused by error in measurement Measured property Error Efficiency % Unit % Temperature at nose (pyrometer) ±5 ±50 o C - Temperature before bb (calibrated probe) ±5 ±30 o C - Temperature before bb (net, calibrated probe) ±2 ±12 o C - Temperature after eco (calibrated probe) ±2 ±3 o C 0.2 Temperature after eco (net, calibrated probe) ±0.5 ±1 o C 0.05 Air temperature (calibrated probe) ±0.5 ±0.2 o C 0.00 Black liquor HV (KCL) ±0.6 ±0.1 MJ/kgds 1.0 Carbon in black liquor (LECO) ±1.4 ±0.5%-unit 0.05 Hydrogen in black liquor (LECO) ±0.2 ±0.01%-unit 0.03 Sulfur in black liquor (KCL) ±5 ±0.2%-unit 0.6 Reduction (1 sample, KCL) ±1 ±1.0% 0.1 Reduction (10 samples average, KCL) ±0.2 ±0.2% 0.03 Dry-solids (calibrated refractometer) ±2.5 ±2% 0.7 Dry-solids (1 sample, KCL) ±0.5 ±0.4% 0.1 NOx (calibrated mill measurement 0-200) ±3 ±6 ppm - NOx (outside accredited firm) ±3 ±2 ppm - SO 2 (calibrated mill measurement 0-500) ±3 ±15 ppm - SO 2 (outside accredited firm) ±3 ±2 ppm - 64 Revista O Papel - dezembro/december 2011
8 DISCUSSION A method to calculate the recovery boiler efficiency based on the lower heating value has been presented. Calculating recovery boiler efficiency based on EN :2003 Water-tube boilers and auxiliary installations - Part 15: Acceptance tests can be done if the recovery boiler specific questions are accounted for. The recovery boiler efficiency is similar to the efficiency of other biomass boilers if the process work that goes into reducing reactions is taken into account. The use of this analysis for other types of boilers than modern kraft recovery boilers needs careful consideration. Without changes, its application to other types of boilers is not possible. Modifications are needed to accommodate NSSC boilers, magnesium and calcium based recovery units, boilers with direct contact evaporators, and gasification of black liquor. One of the biggest differences to earlier procedures is that this work includes all the applicable flows to furnace. Typical additional flows to the furnace are: the combustion of weak non condensable gases (DNCG or HVLC NCG), the combustion of strong non condensable gases (CNCG or LVHC NCG), the combustion of dissolving tank vent gases, and the combustion of methanol and turpentine. In addition to the above, with black liquor other streams are burned, makeup, waste acids, biosludge and soap. Because the balances are based on the as-fired liquor, all the streams added to the virgin black liquor are automatically included. It is recommended that the maximum allowable flows for each stream during the performance testing are defined. Typically changes in these additional streams cannot be accepted during the performance testing. It is recommended that the testing is done with all typical additional flows on. Such flows are waste acids from the chemical manufacture and biosludge. Similarly, all individual flows to the furnace, like DNCG, CNCG and dissolving tank vent gases, should be operated during the performance testing. Acknowledgements This paper is based on the document Recovery boiler performance testing - Material and energy balance [13] which has been compiled under the Finnish Recovery Boiler Committee s Black Liquor Subcommittee. The chairman was Keijo Salmenoja - Oy Metsä-Botnia Ab. The members were Esa Ruonala Stora - Enso Oyj, Sanna Siltala - UPM-Kymmene Oyj, Aki Hakulinen - Metso Power Oy, Kurt Siren - Oy Keskuslaboratorio-Centrallaboratorium AB, Juha Koskiniemi - Andritz Oy, Mika Salo - Oy Metsä-Botnia Ab, Jyrki Rautkorpi - Jaakko Pöyry Oy, Mikko Hupa - Åbo Akademi. Secretary for the subcommittee was Jens Kohlmann - Jaakko Pöyry Oy. Several helpful comments were received from members that facilitated the creation of the document. We especially want to extend our gratitude to Rainer Backman, Umeå University and Saied Kochesfahani, US Borax Inc., who helped to improve the accuracy of thermodynamical data for borates. References 1. Performance test procedure: sodium base recovery units, 1996, CA Report No , March 1996, Tappi Press, 54 p. ISBN DIN 1942, Acceptance Testing of Steam Generators Deutsches Institut Fur Normung E.V. (German National Standard), 01-Feb-1994, 50 p. 3. EN :2003. Water-tube boilers and auxiliary installations - Part 15: Acceptance tests. No. 97/23/EC 2003, CEN European Committee for Standardization, 89 p. 4. Gullichsen, Johan, 1968b, Heat values of pulping spent liquors. Preprints of the Symposium on Recovery of Pulping Chemicals, Helsinki, The Finnish Pulp and Paper research Institute and Ekono, pp Clement, J. L., Coulter, J. H. and Duda, S., 1963, B&W Kraft recovery unit performance calculations. Tappi, Vol. 46, No. 2, p Adams, Terry N., Frederick, Wm. James, Grace, Thomas M., Hupa, Mikko, Iisa, Kristiina, Jones, Andrew K., Tran, Honghi, 1997, Kraft recovery boilers. AF&PA, TAPPI PRESS, Atlanta, 381 p. ISBN Vakkilainen, Esa, 2000, Recovery boiler. Chapter 13 in Chemical Pulping, Book 6, series editors Johan Gullichsen and Carl-Johan Fogelholm, Finnish Paper Engineers Association and TAPPI. ISBN European Commission, Integrated Pollution Prevention and Control (IPPC), Reference Document on Best Available Techniques for Large Combustion Plants. 2006, European Integrated Pollution Prevention and Control Bureau, July 2006, 618 p. 9. Vakkilainen, Esa, 2000, Chemicals recovery. Chapter 11 in Chemical Pulping, Book 6, series editors Johan Gullichsen and Carl-Johan Fogelholm, Finnish Paper Engineers Association and TAPPI. ISBN Chase, M.W., Jr., 1998, NIST-JANAF Themochemical Tables, Fourth Edition, J. Phys. Chem. Ref. Data, Monograph 9, 1998, Björk, Maria, Sjögren, Tomas, Lundin, Tommy, Rickards, Helen and Kochesfahani, Saied, 2005, Partial borate autocausticizing trial increases capacity at Swedish mill. Tappi Journal, Vol. 84, No. 4, April 2001, pp p. 12. Ahtila, Pekka, 1997, Optimization of recovery boiler plant air systems by new design method and process integration. Acta polytechnica Scandinavica. Me. Mechanical engineering series; 127, Finnish Academy of Technology, 137 p. ISBN Vakkilainen, Esa K., 2006, Recovery boiler performance testing - Material and energy balance. Finnish Recovery Boiler Committee, Report 5/ , 55 p. dezembro/december Revista O Papel 65
Boiler Calculations. Helsinki University of Technology Department of Mechanical Engineering. Sebastian Teir, Antto Kulla
Helsinki University of Technology Department of Mechanical Engineering Energy Engineering and Environmental Protection Publications Steam Boiler Technology ebook Espoo 2002 Boiler Calculations Sebastian
Boiler efficiency measurement. Department of Energy Engineering
Boiler efficiency measurement Department of Energy Engineering Contents Heat balance on boilers Efficiency determination Loss categories Fluegas condensation principals Seasonal efficiency Emission evaluation
Module 5: Combustion Technology. Lecture 33: Combustion air calculation
1 P age Module 5: Combustion Technology Lecture 33: Combustion air calculation 2 P age Keywords: Heat of combustion, stoichiometric air, excess air, natural gas combustion Combustion air calculation The
TRIAL CHEMICAL CLEANING OF FOULED APH BASKETS
TRIAL CHEMICAL CLEANING OF FOULED APH BASKETS Dr. Abhay Kumar Sahay, AGM(CC OS) Bijay Manjul, AGM( Operation) Kahalgaon Boiler has three inputs Steam generator 1. WATER 2. COAL 3. AIR Burner Air preheater
Stora Enso Fors Ltd Sweden
THE ANALYSIS REPORT OF PLANT NO. 3 Cofiring of biomass - evaluation of fuel procurement and handling in selected existing plants and exchange of information (COFIRING) - Part 2 Stora Enso Fors Ltd Sweden
COMBUSTION. In order to operate a heat engine we need a hot source together with a cold sink
COMBUSTION In order to operate a heat engine we need a hot source together with a cold sink Occasionally these occur together in nature eg:- geothermal sites or solar powered engines, but usually the heat
Basics of Steam Generation
Helsinki University of Technology Department of Mechanical Engineering Energy Engineering and Environmental Protection Publications Steam Boiler Technology ebook Espoo 2002 Basics of Steam Generation Sebastian
Recovery Boiler Research Needs An Industry Perspective
Recovery Boiler Research Needs An Industry Perspective Andrew Jones International Paper 7th International Colloquium on Black Liquor Combustion and Gasification International Paper Recovery Operation Goals
Energy Efficient Operations and Maintenance Strategies for Boilers
Energy Efficient Operations and Maintenance Strategies for Boilers Large, complex and widely used, industrial boilers are major consumers of fuel. Proper operations and maintenance (O&M) procedures must
Continuous flow direct water heating for potable hot water
Continuous flow direct water heating for potable hot water An independently produced White Paper for Rinnai UK 2013 www.rinnaiuk.com In the 35 years since direct hot water systems entered the UK commercial
Webpage: www.ijaret.org Volume 3, Issue IV, April 2015 ISSN 2320-6802
Efficiency Assessment and Improvement of at Super Thermal Power Station Vikram Singh Meena 1, Dr. M.P Singh 2 1 M.Tech in Production Engineering, Jagannath University, Jaipur, Rajasthan, India [email protected]
CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2
WASTE HEAT BOILERS CONTENTS 1 INTRODUCTION... 3 2 CONCEPTION OF WASTE HEAT BOILERS... 4 2.1 Complex Solution...4 2.2 Kind of Heat Exchange...5 2.3 Heat Recovery Units and Their Usage...5 2.4 Materials
Assignment 8: Comparison of gasification, pyrolysis and combustion
AALTO UNIVERSITY SCHOOL OF CHEMICAL TECHNOLOGY KE-40.4120 Introduction to biorefineries and biofuels Assignment 8: Comparison of gasification, pyrolysis and combustion Aino Siirala 309141 Assignment submitted
BOILER TUNE-UP GUIDE FOR NATURAL GAS AND LIGHT FUEL OIL OPERATION GREG HARRELL, PH.D., P.E.
ENERGY MANAGEMENT SERVICES Greg Harrell, Ph.D., P.E. 341 Willocks Drive Jefferson City, Tennessee 37760 Telephone: (865) 719-0173 Email: [email protected] BOILER TUNE-UP GUIDE FOR NATURAL GAS AND
Performance of the Boiler and To Improving the Boiler Efficiency Using Cfd Modeling
IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 8, Issue 6 (Sep. - Oct. 2013), PP 25-29 Performance of the Boiler and To Improving the Boiler Efficiency
RECOMMENDED GOOD PRACTICE THERMAL OXIDATION OF WASTE STREAMS IN BLACK LIQUOR RECOVERY BOILERS THE BLACK LIQUOR RECOVERY BOILER ADVISORY COMMITTEE
RECOMMENDED GOOD PRACTICE THERMAL OXIDATION OF WASTE STREAMS IN BLACK LIQUOR RECOVERY BOILERS THE BLACK LIQUOR RECOVERY BOILER ADVISORY COMMITTEE April 2013 Notice and Disclaimer of Liability Concerning
Best Practice in Boiler Water Treatment
Best Practice in Boiler Water Treatment Boiler Water Treatment Part 2 Internal Treatment Objectives of Internal Water Treatment 1 To control the level of total dissolved solids (TDS) within the boiler
The soot and scale problems
Dr. Albrecht Kaupp Page 1 The soot and scale problems Issue Soot and scale do not only increase energy consumption but are as well a major cause of tube failure. Learning Objectives Understanding the implications
Online monitoring of flue gas emissions in power plants having multiple fuels
Preprints of the 19th World Congress The International Federation of Automatic Control Cape Town, South Africa. August 24-29, 214 Online monitoring of flue gas emissions in power plants having multiple
Basics of Kraft Pulping & Recovery Process. Art J. Ragauskas Institute of Paper Science and Technology Georgia Institute of Technology
Basics of Kraft Pulping & Recovery Process Art J. Ragauskas Institute of Paper Science and Technology Georgia Institute of Technology Outline History Goals Process Overview Kraft Pulping Process Kraft
Steam Generation Efficiency Module Blowdown Losses Section
Steam End User Training Steam Generation Efficiency Module Blowdown Losses Section Slide 1 Blowdown Losses Module This section will discuss blowdown loss and its affect on boiler efficiency. [Slide Visual
Enhanced power and heat generation from biomass and municipal waste. Torsten Strand. Siemens Power Generation Industrial Applications
Enhanced power and heat generation from biomass and municipal waste Torsten Strand Siemens Power Generation Industrial Applications Enhanced power and heat generation from biomass and municipal waste Torsten
B0401 Abstract 029 Oral Presentation Session B04 Innovative Applications and Designs - Tuesday, July 1, 2008 16:00 h
Reference System for a Power Plant Based on Biomass Gasification and SOFC Richard Toonssen, Nico Woudstra, Adrian H.M. Verkooijen Delft University of Technology Energy Technology, Process & Energy department
Carbon Dioxide Membrane Separation for Carbon Capture using Direct FuelCell Systems
Carbon Dioxide Membrane Separation for Carbon Capture using Direct FuelCell Systems DFC Technology Used as Electrochemical Membrane for CO 2 Purification and Capture during Power Generation FCE s Direct
COMBUSTION. By: Michael Biarnes. In collaboration with: Bill Freed and Jason Esteves. E Instruments International LLC - www.e-inst.
COMBUSTION By: Michael Biarnes In collaboration with: Bill Freed and Jason Esteves E Instruments International LLC - www.e-inst.com 1 Combustion What is Combustion? Combustion takes place when fuel, most
Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas
Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas Mark Schiffhauer, ATSI Engineering Services Cameron Veitch, Combustion and Energy Systems Scott Larsen, New York State Energy
steam centre of excellence Steam Boiler System Optimization
Steam Boiler System Optimization Introduction Gas Cost Metering Fluids Fuel, Water, Steam Steam Costs Boiler House Stack Losses Boiler Waterside Surfaces Blowdown Current Natural Gas Cost Projected Cost
Boiler Tune-up Guide
Boiler Tune-up Guide National Emission Standards for Hazardous Air Pollutants for Area Sources: Industrial, Commercial, and Institutional Boilers What is a boiler tune-up? 40 CFR Part 63 Subpart JJJJJJ
OPTICAL DETECTION OF KCl VAPOR AND ATOMIC K RELEASES FROM BIOMASS FUELS COMBUSTED IN SINGLE PARTICLE REACTOR
OPTICAL DETECTION OF KCl VAPOR AND ATOMIC K RELEASES FROM BIOMASS FUELS COMBUSTED IN SINGLE PARTICLE REACTOR Tapio Sorvajärvi*, Juha Toivonen Tampere University of Technology Department of Physics, Optics
Module 5: Combustion Technology. Lecture 34: Calculation of calorific value of fuels
1 P age Module 5: Combustion Technology Lecture 34: Calculation of calorific value of fuels 2 P age Keywords : Gross calorific value, Net calorific value, enthalpy change, bomb calorimeter 5.3 Calculation
Extracting Valuable Lignin for Biorefinary Production and Replacement of Fossil Fuels
Extracting Valuable Lignin for Biorefinary Production and Replacement of Fossil Fuels Extrayendo valiosa lignina para Producción en Biorefinería y sustitución de Combustibles Fósiles Anders Larsson Martin
Advanced Steam Parameters in a Large Scale CFB Application Operating on REF and Biofuels background and experiences
Advanced Steam Parameters in a Large Scale CFB Application Operating on REF and Biofuels background and experiences Matts Strömberg Soderenergi AB, Sweden Presented at Power Gen Europe 2011 Milan, Italy
Evaporator and Recovery Boiler Energy Efficiency
Evaporator and Recovery Boiler Energy Efficiency Executive Summary The white paper begins with a brief review of Valmet's Web Academy, which, along with Dynamic Simulator Training, can be used to train
Validated methods for flue gas flow rate calculation with reference to EN 12952-15
55106284-PGR/R&E 12-7222 Validated methods for flue gas flow rate calculation with reference to EN 12952-15 Nyköping, Ratcliffe-on-Soar, Arnhem; January 31, 2012 Authors David Graham E.ON New Build & Technology;
CHEM 105 HOUR EXAM III 28-OCT-99. = -163 kj/mole determine H f 0 for Ni(CO) 4 (g) = -260 kj/mole determine H f 0 for Cr(CO) 6 (g)
CHEM 15 HOUR EXAM III 28-OCT-99 NAME (please print) 1. a. given: Ni (s) + 4 CO (g) = Ni(CO) 4 (g) H Rxn = -163 k/mole determine H f for Ni(CO) 4 (g) b. given: Cr (s) + 6 CO (g) = Cr(CO) 6 (g) H Rxn = -26
Reporting: one report / group. The results of the carryover load calculations will also be reported to Metsä Fibre, Rauma.
Carryover load Your task is to use the obtained experimental result from the probe measurement in combination with the information given in this handout to calculate the carryover load (g/nm 3 dry flue
THE HUMIDITY/MOISTURE HANDBOOK
THE HUMIDITY/MOISTURE HANDBOOK Table of Contents Introduction... 3 Relative Humidity... 3 Partial Pressure... 4 Saturation Pressure (Ps)... 5 Other Absolute Moisture Scales... 8 % Moisture by Volume (%M
Forgotten savings: Heat recovery from surface blowdown
Forgotten savings: Heat recovery from surface blowdown 1. Introduction The purpose of this article is to inform thermal plant operators of the interesting fuel savings that can be obtained by recovering
Condensing Economizers Workshop Enbridge Gas, Toronto. MENEX Boiler Plant Heat Recovery Technologies. Prepared by: Jozo Martinovic, M A Sc, P Eng
Condensing Economizers Workshop Enbridge Gas, Toronto MENEX Boiler Plant Heat Recovery Technologies Prepared by: Jozo Martinovic, M A Sc, P Eng MENEX Innovative Solutions May 15, 2008 MENEX INC. 683 Louis
STOICHIOMETRY OF COMBUSTION
STOICHIOMETRY OF COMBUSTION FUNDAMENTALS: moles and kilomoles Atomic unit mass: 1/12 126 C ~ 1.66 10-27 kg Atoms and molecules mass is defined in atomic unit mass: which is defined in relation to the 1/12
APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES
APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES INTRODUCTION This tutorial is designed for students wishing to extend their knowledge of thermodynamics to a more
Chapter 2.2: Boilers
Chapter 2.2: Boilers Part I: Objective type Questions and Answers 1. The minimum capacity of any closed vessel which generates steam under Indian Boilers Regulation Act is. a) 2.275 liters b) 22.75 kilo
CFD Simulation of Biofuel and Coal Co-Combustion in a Pulverized Coal Fired Furnace
CFD Simulation of Biofuel and Coal Co-Combustion in a Pulverized Coal Fired Furnace Perttu Jukola & Marko Huttunen / VTT Technical Research Centre of Finland IFRF, Finnish-Swedish Flame Days, 17.-18.04.2013,
HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS
HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS William K. Scullion, Application Engineering Leader, MEGTEC Systems, De Pere, WI Introduction Competitive pressures continuously motivate us to examine our
The Single Absorption Scrubbing Sulfuric Acid Process
The Single Absorption Scrubbing Sulfuric Acid Process Leonard J. Friedman, Samantha J. Friedman Acid Engineering & Consulting, Inc. 17770 Deauville Lane, 33496, USA [email protected] Keywords: Sulfuric
Improving Energy Efficiency through Biomass Drying
Improving Energy Efficiency through Biomass Drying Gilbert McCoy, Senior Energy Systems Engineer Northwest CHP Technical Assistance Partnership International District Energy Association Woody Biomass CHP
EFFICIENCY WITH DIFFERENT GCV OF COAL AND EFFICIENCY IMPROVEMENT OPPORTUNITY IN BOILER
EFFICIENCY WITH DIFFERENT GCV OF COAL AND EFFICIENCY IMPROVEMENT OPPORTUNITY IN BOILER Chetan T. Patel 1, Dr.Bhavesh K. patel 2, Vijay K. Patel 3 M.E. in Energy Engineering 4 th sem, Government Engineering
Combustion Analysis Basics
Combustion Analysis Combustion Analysis Basics An Overview of Measurements, Methods and Calculations Used in Combustion Analysis COMBUSTION ANALYSIS BASICS An Overview of Measurements, Methods and Calculations
Natural Gas Conversions of Existing Coal-Fired Boilers
White Paper MS-14 Natural Gas Conversions of Existing Coal-Fired s Authors: F.J. Binkiewicz Jr., P.E. R.J. Kleisley B.E. McMahon J.E. Monacelli D.A. Roth D.K. Wong Babcock & Wilcox Power Generation Group,
University of Iowa Power Plant
University of Iowa Power Plant Contents Purpose... 2 History... 3 Cogeneration... 6 Boilers... 7 Environmental Impact... 10 Steam Turbine Generators... 12 Modernization... 14 Biomass Fuel Initiative...
Drying of Woody Biomass. Process Engineering / GEA Barr-Rosin
Drying of Woody Biomass BioPro Expo & Marketplace / Atlanta, GA / March 14-16, 2011 Drying of Woody Biomass Conventional Direct Fired Dryer Technology Proprietary work of the Copyright Owner Issues with
Calculate Available Heat for Natural Gas Fuel For Industrial Heating Equipment and Boilers
For Industrial Heating Equipment and Boilers Prepared for California Energy Commission (CEC) Prepared By: Southern California Gas Company (A Sempra Energy Utility) E3M Inc. May 2012 i Disclaimer The CEC
Waste to Energy in Düsseldorf. for a clean city.
Waste to Energy in Düsseldorf for a clean city. Waste Management in Düsseldorf. Düsseldorf s public utilities company known as Stadtwerke Düsseldorf operates a waste to energy plant (WtE) that has been
1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.
Sample Questions REVISED FIRST CLASS PARTS A1, A2, AND A3 (NOTE: these questions are intended as representations of the style of questions that may appear on examinations. They are not intended as study
Study on performance and methods to optimize thermal oil boiler efficiency in cement industry
energyequipsys/ Vol 4/No1/June 016/ 53-64 Energy Equipment and Systems http://energyequipsys.ut.ac.ir www.energyeuquipsys.com Study on performance and methods to optimize thermal oil boiler efficiency
The Empirical Formula of a Compound
The Empirical Formula of a Compound Lab #5 Introduction A look at the mass relationships in chemistry reveals little order or sense. The ratio of the masses of the elements in a compound, while constant,
General Chemistry I (FC, 09-10) Lab #3: The Empirical Formula of a Compound. Introduction
General Chemistry I (FC, 09-10) Introduction A look at the mass relationships in chemistry reveals little order or sense. The ratio of the masses of the elements in a compound, while constant, does not
Gas emission measurements with a FTIR gas analyzer - verification of the analysis method Kari Pieniniemi 1 * and Ulla Lassi 1, 2
ENERGY RESEARCH at the University of Oulu 117 Gas emission measurements with a FTIR gas analyzer - verification of the analysis method Kari Pieniniemi 1 * and Ulla Lassi 1, 2 1 University of Oulu, Department
Black Liquor Evaporators: Design and Operation
Black Liquor Evaporators: Design and Operation decades and remains a common sight in older Kraft mill operations. Jean Claude Patel Sales Manager AH Lundberg Associates, Inc. 406 Sagebrush Rd Naperville,
C H A P T E R 3 FUELS AND COMBUSTION
85 C H A P T E R 3 FUELS AND COMBUSTION 3.1 Introduction to Combustion Combustion Basics The last chapter set forth the basics of the Rankine cycle and the principles of operation of steam cycles of modern
1. ENERGY PERFORMANCE ASSESSMENT OF BOILERS
1. ENERGY PERFORMANCE ASSESSMENT OF BOILERS 1.1 Introduction Performance of the boiler, like efficiency and evaporation ratio reduces with time, due to poor combustion, heat transfer fouling and poor operation
RECOVERY BOILER CHEMICAL PRINCIPLES
RECOVERY BOILER CHEMICAL PRINCIPLE Mikko Hupa Åbo Akademi University Department of Chemical Engineering F-050 Turku, Finland 1. INTRODUCTION A black liquor recovery boiler has two main functions. On one
IAPWS Certified Research Need - ICRN
IAPWS Certified Research Need - ICRN ICRN 23 Dew Point for Flue Gas of Power-Plant Exhaust The IAPWS Working Group Industrial Requirements and Solutions has examined the published work in the area of dew-point
By K.K.Parthiban / Boiler specialist / Venus Energy Audit System
FINE TUNING EXPERIENCE OF A CFBC BOILER By K.K.Parthiban / Boiler specialist / Venus Energy Audit System Introduction The Industrial boilers have been seeing a growth in capacity in the recent years. Current
2nd IEA Oxyfuel Combustion Conference
2nd IEA Oxyfuel Combustion Conference Oxyfuel Combustion with Hitachi's DST - Burner at Vattenfall's 30Wth Pilot Plant at Schwarze Pumpe S. Rehfeldt, F.-P. Schiffer, P. Weckes, C. Bergins, K.-D. Tigges
Honors Chemistry: Unit 6 Test Stoichiometry PRACTICE TEST ANSWER KEY Page 1. A chemical equation. (C-4.4)
Honors Chemistry: Unit 6 Test Stoichiometry PRACTICE TEST ANSWER KEY Page 1 1. 2. 3. 4. 5. 6. Question What is a symbolic representation of a chemical reaction? What 3 things (values) is a mole of a chemical
Committed to make a better world
Committed to make a better world 1. Higher Availability & Reliability 2. Highest Plant efficiency 3. Lower Heat Rate 4. Minimum Auxiliary Power Consumption 5. Minimum Emission of Pollutants Committed to
1.3 Properties of Coal
1.3 Properties of Classification is classified into three major types namely anthracite, bituminous, and lignite. However there is no clear demarcation between them and coal is also further classified
HOW TO SELECT A LOW VOLUME (L.V ) BOILER
HOW TO SELECT A LOW VOLUME (L.V ) BOILER FREQUENTLY ASKED QUESTIONS OR COMMENTS ON BOILERS Dear Potential Customer: Low Volume Operator Exempt boilers have been marketed in Ontario to eliminate the requirement
Balancing chemical reaction equations (stoichiometry)
Balancing chemical reaction equations (stoichiometry) This worksheet and all related files are licensed under the Creative Commons Attribution License, version 1.0. To view a copy of this license, visit
HYBRID WAY EAF OFF GAS HEAT RECOVERY -ECORECS- MASANARI YAMAZAKI*1, YASUHIRO SATO*2, RYUTARO SEKI*3
HYBRID WAY EAF OFF GAS HEAT RECOVERY -ECORECS- BY MASANARI YAMAZAKI*1, YASUHIRO SATO*2, RYUTARO SEKI*3 SYNOPSIS JP Steel Plantech Co. has developed Hybrid system for EAF off-gas heat recovery, with EAF
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Introduction SRU s (Sulfur Recovery Units) are critical pieces of equipment in refineries and gas plants. SRUs remove sulfur compounds from certain
OPPORTUNITIES FOR HEAT RATE REDUCTIONS IN EXISTING COAL- FIRED POWER PLANTS: A STRATEGY TO REDUCE CARBON CAPTURE COSTS
CONFERENCE PROCEEDINGS OPPORTUNITIES FOR HEAT RATE REDUCTIONS IN EXISTING COAL- FIRED POWER PLANTS: A STRATEGY TO REDUCE CARBON CAPTURE COSTS by Edward K. Levy, Nenad Sarunac, and Carlos Romero Energy
NAWTEC18-3541 CONCEPTS AND EXPERIENCES FOR HIGHER PLANT EFFICIENCY WITH MODERN ADVANCED BOILER AND INCINERATION TECHNOLOGY
Proceedings of the 18th Annual North American Waste-to-Energy Conference NAWTEC18 May 11-13, 2010, Orlando, Florida, USA NAWTEC18-3541 CONCEPTS AND EXPERIENCES FOR HIGHER PLANT EFFICIENCY WITH MODERN ADVANCED
Optimising Glass Melting Processes with Energy & Mass Balance Calculations
Optimising Glass Melting Processes with Energy & Mass Balance Calculations Hans Mahrenholtz, Linde AG, Andre Ommer, OGIS GmbH, Germany Introduction Glass manufacturers are constantly under pressure to
Chapter 3: Stoichiometry
Chapter 3: Stoichiometry Key Skills: Balance chemical equations Predict the products of simple combination, decomposition, and combustion reactions. Calculate formula weights Convert grams to moles and
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
Energy Saving Fact Sheet Boilers
Energy Saving Fact Sheet Boilers Turn a burning issue into real energy savings You need a boiler to heat your premises and provide hot water or to generate steam for use in industrial processes. Unfortunately,
OUTCOME 2 INTERNAL COMBUSTION ENGINE PERFORMANCE. TUTORIAL No. 5 PERFORMANCE CHARACTERISTICS
UNIT 61: ENGINEERING THERMODYNAMICS Unit code: D/601/1410 QCF level: 5 Credit value: 15 OUTCOME 2 INTERNAL COMBUSTION ENGINE PERFORMANCE TUTORIAL No. 5 PERFORMANCE CHARACTERISTICS 2 Be able to evaluate
IB Chemistry 1 Mole. One atom of C-12 has a mass of 12 amu. One mole of C-12 has a mass of 12 g. Grams we can use more easily.
The Mole Atomic mass units and atoms are not convenient units to work with. The concept of the mole was invented. This was the number of atoms of carbon-12 that were needed to make 12 g of carbon. 1 mole
Tutkimuksen merkitys menestyvässä liiketoiminnassa- Innovaatiosta tuotteeksi
Tutkimuksen merkitys menestyvässä liiketoiminnassa- Innovaatiosta tuotteeksi Matti Rautanen Manager, External Networks, Power-wide R&D Tutkimuksella tulevaisuuteen- seminaari Kaukolämpöpäivät, Kuopio 29.8.2013
Process Integration of Chemical Looping Combustion with Oxygen Uncoupling in a Coal-Fired Power Plant
Process Integration of Chemical Looping Combustion with Oxygen Uncoupling in a Coal-Fired Power Plant Petteri Peltola 1, Maurizio Spinelli 2, Aldo Bischi 2, Michele Villani 2, Matteo C. Romano 2, Jouni
Steam System Efficiency. Bill Lumsden Leidos Engineering
Steam System Efficiency Bill Lumsden Leidos Engineering Steam System Efficiency Steam System Efficiency Key Take-aways: Review of the properties of ice, water, and steam Learn the basics of steam trap
CHAPTER 7 THE SECOND LAW OF THERMODYNAMICS. Blank
CHAPTER 7 THE SECOND LAW OF THERMODYNAMICS Blank SONNTAG/BORGNAKKE STUDY PROBLEM 7-1 7.1 A car engine and its fuel consumption A car engine produces 136 hp on the output shaft with a thermal efficiency
Energy Efficiency in Steam Systems
Energy Efficiency in Steam Systems Fundamentals of Energy Efficiency: An Introductory Workshop April 2008 John S. Raschko, Ph.D. Mass. Office of Technical Assistance www.mass.gov/envir/ota (617) 626-1093
THE OPTIMISATION OF BIOMASS COMBUSTION IN SMALL BOILERS
The optimisation of biomass INFRASTRUKTURA I EKOLOGIA TERENÓW WIEJSKICH INFRASTRUCTURE AND ECOLOGY OF RURAL AREAS Nr 6/28, POLSKA AKADEMIA NAUK, Oddział w Krakowie, s. 63 69 Komisja Technicznej Infrastruktury
Recover Heat from Boiler Blowdown Water
Prepared for California Energy Commission (CEC) Prepared By: Southern California Gas Company (A Sempra Energy Utility) E3M Inc. May 2012 i Disclaimer The CEC and its contractor, Southern California Gas
Calculation of Molar Masses. Molar Mass. Solutions. Solutions
Molar Mass Molar mass = Mass in grams of one mole of any element, numerically equal to its atomic weight Molar mass of molecules can be determined from the chemical formula and molar masses of elements
WATER WALL BOILER FOR AIR AND OXYGEN FIRED CLAUS SULPHUR RECOVERY UNITS
WATER WALL BOILER FOR AIR AND OXYGEN FIRED CLAUS SULPHUR RECOVERY UNITS Abstract Mahin RAMESHNI, P.E. Technical Director, Sulphur Technology [email protected] WorleyParsons 125 West Huntington
COMPARISON CONCERNING TO THE COGENERATION SYSTEMS DEVELOPMENT
COMPARISON CONCERNING TO THE COGENERATION SYSTEMS DEVELOPMENT Radu-Cristian DINU, Ion MIRCEA, Emilia-Marinela DINU University of Craiova, Faculty of Electrotechnique, Electroputere S.A., Craiova [email protected],
OPERATIONS & MAINTENANCE SUBCOMMITTEE RECOVERY BOILER SAFETY AUDIT GUIDELINES
AMERICAN FOREST & PAPER ASSOCIATION AMERICAN FOREST & PAPER ASSOCIATION OPERATIONS & MAINTENANCE SUBCOMMITTEE RECOVERY BOILER SAFETY AUDIT GUIDELINES March 1990 Revised July 2004 Revised May 2012 893 McLean
SUPPLEMENTARY TOPIC 3 ENERGY AND CHEMICAL REACTIONS
SUPPLEMENTARY TOPIC 3 ENERGY AND CHEMICAL REACTIONS Rearranging atoms. In a chemical reaction, bonds between atoms in one or more molecules (reactants) break and new bonds are formed with other atoms to
Exergy: the quality of energy N. Woudstra
Exergy: the quality of energy N. Woudstra Introduction Characteristic for our society is a massive consumption of goods and energy. Continuation of this way of life in the long term is only possible if
How To Make Calcium Carbide
11.4 Calcium Carbide Manufacturing 11.4.1 General Calcium carbide (CaC 2 ) is manufactured by heating a lime and carbon mixture to 2000 to 2100 C (3632 to 3812 F) in an electric arc furnace. At those temperatures,
A Method for Calculating Thermal Efficiency Of the Solid Fuel Fired Boiler Zetao Wang1,a, Yujiao Gong2,b,Xuedong Jing1, c *
A Method for Calculating Thermal Efficiency Of the Solid Fuel Fired Boiler Zetao Wang1,a, Yujiao Gong2,b,Xuedong Jing1, c * 1 Shanghai Institute of Technology, China 2 Chongming Institute of Quality and
Heat Exchangers in Boilers
Helsinki University of Technology Department of Mechanical Engineering Energy Engineering and Environmental Protection Publications Steam Boiler Technology ebook Espoo 2002 Heat Exchangers in Boilers Sebastian
Boiler NOx Emissions and Energy Efficiency
Boiler NOx Emissions and Energy Efficiency Prepared For: Boiler Operators and Facility Managers Prepared By: 100 Montgomery Street, Suite 600 San Francisco, CA 94104 AGENDA Introduction Boiler NOx Formation
IB Chemistry. DP Chemistry Review
DP Chemistry Review Topic 1: Quantitative chemistry 1.1 The mole concept and Avogadro s constant Assessment statement Apply the mole concept to substances. Determine the number of particles and the amount