intelligent Touch Controller Web Software
|
|
|
- Angelina Scott
- 9 years ago
- Views:
Transcription
1 OPERATION MANUAL intelligent Touch Controller Web Software MODEL DCS004A51 Thank you for purchasing intelligent Touch Controller. This operation manual contains notes for safe use of the product. For correct use, be sure to read this manual carefully before use. Store this manual close at hand so that it can be referred to as required.
2 intelligent Touch Controller Web Software Operation manual CONTENTS 1. SAFETY CONSIDERATIONS BEFORE STARTING ABOUT WEB INTERFACE Web Interface of the intelligent Touch Controller OVERVIEW Web System of the intelligent Touch Controller Functions Available for each login name Two Display Modes of the Web Interface Logging into the Web Interface Selecting Display Language BASIC MODE Main Screen Icons on the Screen Information Provided by Indoor Unit Icons Information Provided by HRV Icons Information Provided by Lighting Device, Universal Device, and Zone Icons Information Provided by the Setting Areas Starting/Stopping All the Devices in a Specific Group Starting/Stopping All the Devices in a Specific Zone Switching the Operation Mode Changing the Temperature Setting Changing the Direction of Air Flow and Air Volume Changing the Ventilation Amount and the Freshen Up Function Notes on the Basic Mode Monitoring Operations of All the Devices in a Specific Zone or Group ADVANCED MODE Main Screen Starting/Stopping All the Devices in a Specific Group Starting/Stopping All the Devices in a Specific Zone Starting/Stopping Air Conditioners All Together Switching the Operation Mode Changing the Temperature Setting Resetting Filter/Element Signs Changing the Direction of Air Flow and Air Volume Changing the HRV settings Permitting/Prohibiting Remote Controller Operations Monitoring Operations of All the Devices in a Specific Zone or Group Monitoring Detailed Information Monitoring Detailed Operation Status Monitoring Operation Status of HRVs ABOUT SYSTEM SETTINGS MENU Overview System Settings CREATING SCHEDULES Main Scheduling Screen Schedule dialog box Using the Schedule Menu Creating Regular Schedule Patterns Creating Ex Schedule Patterns Copying or Deleting a Schedule Program Copying or Deleting Schedule Events Naming a Schedule Program Menu Structure of Proportional Distribution Function Display Area Buttons Settings for Excluded Time (Normal Type) Setting Special Calculation Days (Normal Type) Setting Collection Periods of Proportional Distribution Result (Period Settings) Setting Collection Periods of Proportional Distribution Result (with Month Specified) Display Method of Proportional Distribution Result Display Method of Proportional Distribution Result PRECAUTIONS FOR WINDOWS VISTA Precautions for Using Windows Vista BEFORE CONTACTING US: TROUBLESHOOTING AFTER-SALES SERVICE SAFETY CONSIDERATIONS Please read these SAFETY CONSIDERATIONS carefully before installing air conditioning equipment and be sure to install it correctly. After completing the installation, make sure that the unit operates properly during the start-up operation. Please instruct the customer on how to operate the unit and keep it maintained. Also, inform customers that they should store this installation manual along with the operation manual for future reference. This air conditioner comes under the term appliances not accessible to the general public. Meaning of danger, warning, caution and note symbols. DANGER... Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING... Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION... Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. NOTE... Indicates situation that may result in equipment or property-damage-only accidents. Keep these warning sheets handy so that you can refer to them if needed. Also, if this equipment is transferred to a new user, make sure to hand over this operation manual to the new user. DANGER Any abnormalities in the operation of the air conditioner such as smoke or fire could result in severe injury or death. Turn off the power and contact your dealer immediately for instructions. Do not install the unit in an area where flammable materials are present due to risk of explosion resulting in serious injury or death. Safely dispose of the packing materials. Packing materials, such as nails and other metal or wooden parts, may cause stabs or other injuries. Tear apart and throw away plastic packaging bags so that children will not play with them. Children playing with plastic bags face the danger of death due to suffocation. WARNING Ask your dealer for installation of the air conditioner. Incomplete installation performed by yourself may result in a water leakage, electric shock, and fire. Ask your dealer for improvement, repair, and maintenance. Incomplete improvement, repair, and maintenance may result in a water leakage, electric shock, and fire. English 1
3 Improper installation or attachment of equipment or accessories could result in electric shock, short-circuit, leaks, fire or other damage to the equipment. Be sure only to use accessories made by Daikin which are specifically designed for use with the equipment and have them installed by a professional. Ask your dealer to move and reinstall the air conditioner or the remote controller. Incomplete installation may result in a water leakage, electric shock, and fire. Never let the indoor unit or the remote controller get wet. It may cause an electric shock or a fire. Never use flammable spray such as hair spray, lacquer or paint near the unit. It may cause a fire. Do not allow children to play on or around the unit as they could be injured. Never replace a fuse with that of wrong ampere ratings or other wires when a fuse blows out. Use of wire or copper wire may cause the unit to break down or cause a fire. Never inspect or service the unit by yourself. Ask a qualified service person to perform this work. Cut off all electric waves before maintenance. Do not wash the air conditioner or the remote controller with excessive water. Electric shock or fire may result. Do not touch the switch with wet fingers. Touching a switch with wet fingers can cause electric shock. Never touch the internal parts of the controller. Do not remove the front panel because some parts inside are dangerous to touch. In addition, some parts may be damaged by touching. For checking and adjusting internal parts, contact your dealer. Check the unit stand for damage on a continuous basis, especially if it had been in use for a long time. If left in a damaged condition the unit may fall and cause injury. Placing a flower vase or other containers with water or other liquids on the unit could result in a shock hazard or fire if a spill occurs. NOTE Never press the button of the remote controller with a hard, pointed object. The remote controller may be damaged. Never pull or twist the electric wire of the remote controller. It may cause the unit to malfunction. Do not place the controller exposed to direct sunlight. The LCD display may get discolored, failing to display the data. Do not wipe the controller operation panel with benzine, thinner, chemical dustcloth, etc. The panel may get discolored or the coating peeled off. If it is heavily dirty, soak a cloth in water-diluted neutral detergent, squeeze it well and wipe the panel clean. And wipe it with another dry cloth. Dismantling of the unit, treatment of the refrigerant, oil and eventual other parts, should be done in accordance with the relevant local and national regulations. CAUTION Avoid placing the controller in a spot splashed with water. Water coming inside the machine may cause an electric leak or may damage the internal electronic parts. Do not operate the air conditioner when using a room fumigation - type insecticide. Failure to observe could cause the chemicals to become deposited in the unit, which could endanger the health of those who are hypersensitive to chemicals. Do not turn off the power immediately after stopping operation. Always wait at least five minutes before turning off the power. Otherwise, water leakage and trouble may occur. The appliance is not intended for use by young children or infirm persons without supervision. The remote controller should be installed in such a way that children cannot play with it. 2 English
4 2. BEFORE STARTING Before using the web interface of the intelligent Touch Controller, be sure to check that the target PC meets the following requirements according to the software version on the intelligent Touch Controller. CPU OS Pentium III 800 MHz or compatible or higher Windows 2000 Service Pack 4 or later 3 Windows XP Service Pack 2 or later Pentium III 1 GHz or compatible or higher Windows Vista Business Memory 256MB or more 1 GB or more Free Disk Space Network Speed Video card display Browser Java plugin 100MB or more (required for installing Java plug-in) 10 Base-T or higher Resolution: (XGA) or more Maximum number of simultaneous display colors: or more Internet Explorer 6.0SP2 or later 1 1: Be sure to use IE 6.0 SP2 or later. If IE 6.0 SP2 or later is not installed, obtain it from the Microsoft website. It is downloadable for free. The web interface may not work on other browsers, such as Netscape, may not work correctly. 2: Be sure to use J2SE (Java2 Platform Standard Edition). The available Java plug-in version varies with the software version on the intelligent Touch Controller. The intelligent Touch Controller may not operate properly if the Java plugin version is wrong. Download the right Java plug-in from the SUN website (for free) or contact the dealer from which you purchased this product. Software ver. on i Touch controller ~ ~ Internet Explorer J2SE (Java2 Platform Standard Edition) Ver _04 or Ver Java plug-in ver _ : Windows 2000 (SP4 or later) can be used on the condition that the version of the software on the intelligent Touch Controller is or older. The intelligent Touch Controller may not operate properly if the version is or later. 4: Version 4.33 and later ones are IE7 compatible. 3. ABOUT WEB INTERFACE 3-1 Web Interface of the intelligent Touch Controller Permissions: Privileges Given to Each Login Name There are two categories of login users: General User who can perform basic operations via the web interface and Administrator who can setup the system and change system settings. Two Display Modes You can select the display mode from two modes during login process: the Basic mode which provides a simple and easy-to-use interface and the Advanced mode which allows you to use advanced settings options. Start/Stop Operation You can uniformly start or stop all the devices in a group, a zone, or multiple zones at once. Advanced Settings for Air Conditioners You can set temperature, operation modes, direction of air flow, air volume, and remote controller mode of all devices in a group, a zone, or multiple zones. Various Operation Modes You can operate devices from a web interface, the intelligent Touch Controller console, or a local remote controller. Also the Administrator can permit or prohibit remote controller operations of devices in a specified group or zone using the web interface. User Administration The Administrator can register or delete General Users who can operate air conditioners via the web interface, and also set/ change his/her own password and all General Users passwords. Scheduling Function The Administrator can precisely schedule operations for a specific group or zone of devices. Weekly schedule and 10 extra schedules can be created. See page [5] Basic Mode See page [7] Advanced Mode See page [22] Basic Mode See page [17] Advanced Mode See page [23] Basic Mode See page [18] Advanced Mode See page [24] Advanced Mode See page [28] See page [38] See page [41] Proportional Distribution Control This function makes it possible to measure the total power consumption of the air conditioners of facilities, such as a tenant building, with a meter and calculate the power consumption of each air conditioner on a tenant basis. The function is available on the website if it is used together with the proportional distribution software as an optional application. See page [49] English 3
5 4. OVERVIEW 4-1 Web System of the intelligent Touch Controller The Administrator can assign (or restrict) one or more air conditioners to each General User. In the following Figure 1, User 01, User 02, and User 03 can operate and monitor only their local air conditioners but User 64 can operate/monitor air conditioners that other General Users can also operate/monitor. Figure 1: Example of user settings User User 1 User User User 3 User 64 User 3 Administrator LAN Inter-device communication Maximum number of the registered users Administrator = 1 General Users = 64 Total = 65 General User assignment User 1: User 2: User 3: User 64: English
6 4-2 Functions Available for each login name There are two categories of login users: General User who can perform basic operations via the web interface and Administrator who can setup the system and change system settings. The following list shows web operations given to each category. Administrator is able to: Operate air conditioners Monitor air conditioners Create schedules Proportional distribution settings Set his/her own password Set or change General User s passwords Register or delete General Users (Up to 64 users) Assign devices to each General User A General User is able to: Operate air conditioners Monitor air conditioners Change his/her own password Privileges exclusive for the Administrator The Administrator can assign zones to each General User. Each General User can operate or monitor only devices specified by the Administrator. 4-3 Two Display Modes of the Web Interface In the login process of the intelligent Touch Controller web interface, users can select either of the following two modes. Basic Mode Advanced Mode This section provides the description of the difference between these two modes. Basic Mode: General Users are able to: Monitor air conditioners Operate air conditioners The Administrator is able to: Operate air conditioners Monitor air conditioners Advanced Mode: General Users are able to: Monitor air conditioners Operate air conditioners Permit and/or prohibit local remote controller operations Change his/her own password The Administrator is able to: Operate air conditioners Monitor air conditioners Permit and/or prohibit local remote controller operations Create schedules Proportional distribution settings Set his/her own password (Administrator password) Set or change General User s passwords Register or delete General Users (Up to 64 users) Assign one or more zones to each General User Privileges exclusive for the Administrator 4-4 Logging into the Web Interface 1.Start Internet Explorer, and input the IP address of the intelligent Touch Controller into the address bar. http: // followed by the address of the intelligent Touch Controller In the case of the example on the figure 1, the IP address of the intelligent Touch Controller is figure 1 2.The software includes the proportional distribution function and others with which a collection file of proportional distribution is output onto the hard disk of the PC. Usual Java applets cannot output the file onto the hard disk of the PC. Therefore, the security warning screen is displayed. When you click the button, the security warning screen is not displayed and the log-in screen is displayed. If you always want to trust the content from the publisher, check Always trust content from this publisher and click the button. Thereafter the security warning screen is not displayed. The log-in screen is displayed automatically whenever the web function is implemented. If you click the button, the security certificate will not be implemented and the screen will close. The Web function cannot be used. To check the signer s certificate to verify its authenticity, select More Information on the dialog and click on Certificate Details. 3.The Main screen (Screen 2) is displayed. User name: Input the user name given by the administrator. Password: Input the password corresponding to the user name. GUI Mode: Select the basic mode or advanced mode by checking the radio button. Basic mode (See page 7) Advanced mode (See page 22) English 5
7 After input, press to log in. 4-5 Selecting Display Language To select a display language to be used for the web interface: Screen 2: Authentication screen 1.Click the button to display the Display language screen (Screen 2). 2.Click the or button to select a language to be used in this screen. 3.Select a language to be used in the web interface by clicking a radio button. 4.To reflect your selection, click the. To cancel your selection, click the. Screen 1: Authentication screen If you are not authenticated, the error message displayed in Figure is displayed. Check your user name and password. Figure If the Administrator attempts to log into the web interface without closing the system menu on the intelligent Touch Controller console, the error message displayed in Figure is displayed. In this case close the system menu, and log into it again. Figure Screen 2: Display language screen If the Administrator, who is logging into the web interface, attempts to log into the web interface via another PC, the error message displayed Figure is displayed. The Administrator cannot log into the web interface via multiple PC at a time. Figure 6 English
8 5. BASIC MODE 5-1 Main Screen The following screen is displayed when logging into the web interface in the Basic mode. This section describes the Main screen shown in the figure. See the next page for more information on each item on this screen. (4) The above figure shows the Main screen displayed in the Icon display mode. (4) The figure to the left shows the Main screen displayed in the List display mode. English 7
9 Display Areas on the Main Screen Zone tree area: When you select a zone in this area, devices included in the zone appear in the main display area. Main display area: Displays the devices in the zone selected in the zone tree area. Setting area: This area provides status information for each device. You can also change the settings. The contents of this area vary depending on the type of the devices selected in the main display area. Group setting area (Air conditioner) (See page 12) Group setting area (HRV) (See page 13) Group setting area (Lighting device) (See page 14) Group setting area (Universal device) (See page 15) Zone setting area (See page 16) For more information, see the appropriate page. (4) Zone name bar: Displays the name of the zone selected in the Zone Tree Area or the Monitoring (Zone List) status report. Buttons and Other Information Boxes Login name display Displays the login name of the user currently logging into the web interface. Changes the main display area to the Icon display mode. Changes the main display area to the List display mode. Icons in the setting area [HRV Devices] A device registered as an HRV device is displayed as an HRV device icon (Figure 2). Icons in the setting area [Di or Dio Units] When a device is registered as a Di or Dio unit and a lighting device icon is assigned to it using the group setting function of the intelligent Touch Controller console, it appears as a lighting device icon (Figure 3). When a device is registered as a Di or Dio unit and an icon other than the lighting device icon is assigned to it using the group setting function of the intelligent Touch Controller console, it is displayed as displayed in Figure 4: Universal device icon. Icons in the setting area Figure 1: Indoor unit icon Figure 2: HRV icon Figure 3: Lighting device icon Icons in the main display area 25 C Icons in the main display area Icons in the main display area Updates zone or group status information in the main display area with the most recent data of the intelligent Touch Controller. Allows a user to log off the interface and return to the authentication screen. Figure 4: Universal device icon Increase/reduce button Increases or reduces the status display area. Increase: Displays the status display area. Reduce: Hides the status display area. Increase button Reduce button 5-2 Icons on the Screen Each icon represents one of the categories shown in the figures to the right. Devices are grouped into these categories in advance using the intelligent Touch Controller console. Icon assigned to each device cannot be changed via the web interface. This section explains features of each icon. [Indoor Units] A device registered as an indoor unit is displayed as an indoor unit icon (see Figure 1). In the Icon display mode, a temperature value next to each icon in the main display area represents the set temperature of the device. [Zone] Each zone is displayed as displayed in Figure 5: Zone icon. In the Icon display mode, a temperature value next to each icon in the main display area represents the set temperature of the representative unit. Refer to page 21 for more information on the representative unit. Icons in the setting area No zone icon is displayed in the setting area. Figure 5: Zone icon Icons in the main display area 28 C 8 English
10 5-3 Information Provided by Indoor Unit Icons [OPERATION MODE] Either of the mode icons to the left COOL HEAT FAN DRY AUTO DEPENDENT [Start/Stop state] [Error] 28 C 28 C OFF ON Communication error Device error [Direction of air flow] In the Swing mode the direction changes in the following order and this pattern repeats permanently: [Air volume] High Middle Low English 9
11 5-4 Information Provided by HRV Icons [Ventilation mode] Automatic ventilation All heat exchanger ventilation Normal ventilation [Ventilation Amount] Low High AUTO Low (Fresh up) High (Fresh up) AUTO (Fresh up) [Start/Stop state] [Error] OFF ON Communication error Device error 10 English
12 5-5 Information Provided by Lighting Device, Universal Device, and Zone Icons [Universal device: Start/Stop state] [Universal device: Error] OFF Start 1 Communication error Device error [Lighting device: Start/Stop state] [Lighting device: Error] Turning off Turning on Communication error Device error [Zone: Start/Stop state] [Zone: Error] 28 C 28 C OFF Start 1 Communication error Device error 1 The icon color of an operational device depends on the setting on the intelligent Touch Controller console. English 11
13 5-6 Information Provided by the Setting Areas Air Conditioner Group: Group name Status icon Start / Stop (4) System status display area (5) Operation mode (7) Room temperature (6) Sign display area (8) Setpoint (9) Air flow flap (10) Fan speed Group name Displays the exact name of the selected group. Status icon Displays the current status. (See page 9) Start / Stop Displays the Start/Stop state of the air conditioners. You can start or stop the air conditioners, if required. (See page 17) (4) System status display area Displays the system status. One of the following five icons may appear. (5) Operation mode Displays the operation mode of the air conditioners. You can select a desired mode, if required. (See page 18) (6) Sign display area Provides information on schedule programs and filter signs. Indicates that the selected group is associated with one or more schedule programs. Indicates that the selected group has one or more illuminated filter/element signs. :Forced off Central controlled :Under centralized control System Error :Abnormal system :Inter-central-device communication error :Indicates that transmission to the intelligent Touch Controller is in progress. (7) Room temperature Displays the current room temperature. Since the suction temperature of air conditioners is used, this may not correspond to the actual room temperature. (8) Setpoint Displays the temperature setting of air conditioners. You can change this value, if required. (See page 19) (9) Air flow flap Displays the direction of air flow of air conditioners. You can change this setting, if required. (See page 19) (10)Fan speed Displays the air volume of air conditioners. You can change this setting, if required. (See page 19) 12 English
14 HRV Group: Group name Start / Stop (4) System status display area Status icon (5) Ventilation mode (6) Sign display area (7) Ventilation amount setting (8) Freshen up function setting Group name Displays the exact name of the selected group. Status icon Displays the current status. (See page 10) Start / Stop Displays the Start/Stop state of the HRVs. You can start or stop the HRVs, if required. (See page 17) (4) System status display area Displays the system status. One of the following five icons may appear. (5) Ventilation mode Displays the ventilation mode of HRVs. You can select a desired mode, if required. (See page 18) (6) Sign display area Provides information on schedule programs and filter signs. Indicates that the selected group is associated with one or more schedule programs. Indicates that the selected group has one or more illuminated filter/element signs. :Forced off Central controlled :Under centralized control System Error :Abnormal system :Inter-central-device communication error :Indicates that transmission to the intelligent Touch Controller is in progress. (7) Ventilation amount setting Displays the Ventilation amount setting. You can change the setting, if required. (See page 20) (8) Freshen up function setting Displays Start/Stop state of the Freshen up function. You can turn the function on or off, if required. (See page 20) CAUTION For some HRV models, (5), (7), and/or (8) may not be configured. In this case, unavailable buttons are grayed out. English 13
15 Lighting Device Group: Group name Start / Stop Status icon Note: CAUTION (5) System status display area (4) Sign display area Group name Displays the exact name of the selected group. Status icon Displays the current status. (See page 11) Start / Stop Displays the Start/Stop state of devices. You can start or stop devices, if required. (See page 17) (4) Sign display area Provides information on schedule programs. Indicates that the selected group is associated with one or more schedule programs. (5) System status display area Displays the system status. One of the following five icons may appear. :Forced off Central controlled :Under centralized control System Error :Abnormal system :Inter-central-device communication error :Indicates that transmission to the intelligent Touch Controller is in progress. CAUTION When lighting devices are connected via Dio units: The Start/Stop buttons can be used. When lighting devices are connected via Di units: The Start/Stop buttons are not displayed. 14 English
16 Universal Device Group: Group name Start / Stop Status icon Note: CAUTION (5) System status display area (4) Sign display area Group name Displays the exact name of the selected group. Status icon Displays the current status. (See page 11) Start / Stop Displays the Start/Stop state of devices. You can start or stop devices, if required. (See page 17) (4) Sign display area Provides information on schedule programs. Indicates that the selected group is associated with one or more schedule programs. (5) System status display area Displays the system status. One of the following five icons may appear. :Forced off Central controlled :Under centralized control System Error :Abnormal system :Inter-central-device communication error :Indicates that transmission to the intelligent Touch Controller is in progress. CAUTION When lighting devices are connected via Dio units: The Start/Stop buttons can be used. When lighting devices are connected via Di units: The Start/Stop buttons are not displayed. English 15
17 Zone: Air conditioner zone: HRV zone: Clicking this tab provides air conditioner zone information. Clicking this tab provides HRV zone information. Di/Dio zone: (see Note) Note: When connecting via Di units, the and buttons are grayed out. Notes on Zone Display: If one or more groups in the selected zone are operational, the Start/Stop state for the zone is [On]. If one or more groups in the selected zone are in an error state, the operation state for the zone is [Error]. If one or more groups in the selected zone have an illuminated filter/element sign, the filter/element sign for the zone also illuminates. An illuminated Auto Control sign informs that the selected zone is associated with one or more schedule programs. In the air conditioner zone area, information on the room temperature, setpoint, operation mode, air volume, and direction of air flow is provided. In the HRV zone area, information on the Ventilation mode, Ventilation amount, and Freshen up setting is provided. Data of the representative unit is displayed, rather than that of the entire zone. Representative Unit: In a zone monitoring process, the following group is selected as the representative unit. In the Icon display mode: the group displayed at the upper left corner In the List display mode: the top group in the list. 16 English
18 5-7 Starting/Stopping All the Devices in a Specific Group Procedure for starting/stopping all the devices in a specific group Start or stop all the air conditioners included in a specific group. This procedure can be used when devices in the selected group are registered as [indoor unit], [HRV], or [Dio unit]. This procedure supports both the Icon display and List display modes. The devices are displayed in the Icon display mode as shown in the following figure: 5-8 Starting/Stopping All the Devices in a Specific Zone Procedure for starting/stopping all the devices in a specific zone Start or stop all the devices included in a specific zone. This procedure supports both the Icon display and List display modes. In the following figure (Screen 1) the devices are displayed in the Icon display mode. Screen 1: Main screen Screen 1: Main screen Procedure 1.On Screen 1: Main screen, select the zone which includes a desired group from the zone tree area. 2.In the main display area the groups belonging to that zone appear. Select the group in this area. 3.The settings of the selected group appear in the setting area. Displayed items vary depending on the category of the group. For more information, see pages 12 to 15. In the figure (Screen 2), an air conditioner group is selected. Click the or button. Screen 2: Group setting area (air conditioners) Procedure 1.On the Main screen (Screen 1), select the Monitoring (Zone list) item from the zone tree option on the left side of the screen. 2.The zone list is displayed in the main display area. Select a desired zone in this area. 3.The setting area changes to the zone setting area (Screen 2). Screen 2: Zone setting area (4) CAUTION In the Basic mode, clicking a button, such as the and, immediately sends your request to air conditioners and you cannot undo your operation. Therefore be sure to click only an appropriate button, especially when your operation target is a zone. At this time, the tab is selected if the selected zone includes air conditioners. The tab is selected if the selected zone includes HRVs, (When both types of devices are not included, no tab is displayed.) 4.Click the or button. CAUTION Clicking the selected button does not send your request. If you want to send the Start request, click Stop and then Start. English 17
19 5-9 Switching the Operation Mode Procedure for switching the operation mode Switch the operation mode of the air conditioner. On the Monitoring screen, operation is allowed with either Icon or List as the display type. In the figure (Screen 1) the devices are displayed in the Icon display mode. Screen 1: Main screen Click one of the following buttons according to your requirement. Changes the operation mode to Cool. Changes the operation mode to Heat. Changes the operation mode to Fan. Changes the operation mode to Dry. Though the operation mode is set to Dry, some indoor unit with no change over option will not be changed to the Dry mode except in the cooling mode. Changes the operation mode to Auto. Changes the operation mode to Dependent. [HRV Devices] Click the tab in the zone setting area (Screen 4) to change the setting of all the devices in a zone. Screen 4: Zone setting The operation mode can be switched by zone or by group. Procedure 1.To change the setting for all the devices in a zone, select the Monitoring (Zone list) item from the zone tree area, and select the zone from the main display area. To change the setting for all the devices in a group, select the zone including the group from the zone tree area, and select the group from the main display area. 2.Change the operation mode in the setting area. The steps required for indoor units are different from ones for HRVs. See the appropriate section. Indoor Units Click the tab in the zone setting area (Screen 2) to change the setting of all the devices in a zone. Screen 2: Zone setting Use the group setting area (Screen 5) to change the setting of all the devices in a group. Screen 5: Group setting (HRV) Click one of the following buttons according to your requirement. Changes the operation mode to Automatic ventilation. Changes the operation mode to All heat exchanger ventilation. Use the group setting area (Screen 3) to change the setting of all the devices in a group. Screen 3: Group setting (air conditioners) Changes the operation mode to Normal ventilation. CAUTION 1 Some of the above setting options may not be used depending on the model of the HRVs. In this case, unavailable buttons are grayed out. CAUTION 2 Mode setting buttons that cannot be used for the selected zone or group are grayed out. Ex.: 18 English
20 5-10 Changing the Temperature Setting Procedure for changing the temperature setting Change the temperature setting of air conditioners. On the Monitoring screen, operation is allowed with either Icon or List as the display type. In the figure (Screen 1) the devices are displayed in the Icon display mode. Screen 1: Main screen The temperature setting can be switched by zone or by group. If all of the air conditioners in the group selected are in Fan operation, temperature setting cannot be changed. Procedure 1.On Screen 1: Main Screen, Monitoring (Zone list), select a zone or a group from the pull-down menu. Select a zone or a group of which the temperature setting is to be changed. To change the setting for all the devices in a group, select the zone including the group from the zone tree area, and select the group from the main display area. 2.Click the setting. or (4) button (4) to change the temperature Ex.: For the Figure 1 zone setting, the temperature settings available are between 20 C and 30 C inclusive. When the temperature setting is 30 C, the actual temperature settings for air conditioners are as shown Figure 2: Figure 2: Zone name Group name Temperature setting Canteen 1 F North 30 C NOTE Range of temperature settings available is the range specified in accordance with the following. Range of temperature settings inherent to the air conditioner main unit. Range of temperature as a result of the restriction by temperature setting limit set on the intelligent Touch Controller console. For more information, refer to the intelligent Touch Controller Software manual Changing the Direction of Air Flow and Air Volume Procedure for changing the direction of air flow/air volume Change the air direction or volume of air conditioners. On the Monitoring screen, operation is allowed with either Icon or List as the display type. In the figure (Screen 1) the devices are displayed in the Icon display mode. The air direction or volume can be changed by zone or by group. Screen 1: Main screen 1 F West 25 C Figure 1: Zone name Group name Range of temperature settings available (see NOTE) Canteen 1 F North 25 C-30 C 1 F West 20 C-25 C (4) (5) Procedure 1.On Screen 1 Monitoring, select a zone or a group from the pull-down menu. Select a zone or a group of which the air direction or volume is to be reset. To change the setting for all the devices in a group, select the zone including the group from the zone tree area, and select the group from the main display area. 2.Click the air flow. Click the or or button (4) to change the direction of button (5) to change the air volume. English 19
21 CAUTION For some air conditioner models, the direction of air flow and/or air volume cannot be changed. In this case these buttons indicated by (4) and (5) are grayed out Changing the Ventilation Amount and the Freshen Up Function Procedure for changing the HRV settings Change the Ventilation amount and the Freshen up settings for HRVs. On the Monitoring screen, operation is allowed with either Icon or List as the display type. In the figure (Screen 1) the devices are displayed in the Icon display mode. Screen 1: Main screen Use the group setting area (Screen 3) to change the settings for HRVs in a group. Use the following buttons on each screen. Screen 3: Group setting area (HRV) Turns the Fresh up function On. Turns the Fresh up function Off. Adjusts the Ventilation amount. Indicates the Automatic ventilation amount setting. Indicates the Strong ventilation amount setting. Indicates the Weak ventilation amount setting. CAUTION For some HRV models, the Fresh up and/or Ventilation amount settings cannot be changed. In this case unavailable buttons are grayed out Notes on the Basic Mode The Ventilation amount and Freshen up settings for all the HRVs in a specific zone or group can be changed all together. Procedure 1.On Screen 1 Monitoring, select a zone or a group from the pull-down menu. Select a zone or a group of which the air direction or volume is to be reset. To change the setting for all the devices in a group, select the zone including the group from the zone tree area, and select the group from the main display area. 2.Click the tab in the zone setting area (Screen 2) to change the settings for HRVs in a zone. Screen 2: Zone setting area CAUTION In the Basic mode, buttons for bulk operation, such as the and for the Advanced mode, are not provided. Therefore a General User, who does not have a privilege to operate All zones, cannot perform bulk start/stop operations. If a General User want to start or stop all the air conditioners, he or she should click the or button manually, for all the zones that he or she has a privilege to operate. CAUTION In the Basic mode, clicking a button, such as,, or, immediately sends your request to air conditioners and you cannot undo your operation. Therefore be sure to click only an appropriate button, especially when your target is a zone. CAUTION Clicking the selected button (see the above figure) does not send your request. If you want to send the Start request, click Stop and then Start. 20 English
22 5-14 Monitoring Operations of All the Devices in a Specific Zone or Group Procedures for monitoring zone or group operations Monitor operations in both the Icon and List display modes. Click the or button to switch the display mode. Screen 1: Main screen (Icon display mode) In the List Display Mode In the main display area, information on the Start/Stop state, presence/absence of malfunction, Auto Control setting, and filter/element sign, temperature setting, operation mode, and room temperature for that zone or group is provided. When a zone is selected, the setting area (Screen 1) displays the settings of the representative unit. Screen 2: Main screen (List display mode) Operations can be monitored by zone or by group. To monitor operations of devices in a zone, select the Monitoring (Zone list) item from the zone tree area on the left side of the screen. The operation status is displayed in the main display area. To monitor operations of devices in a group, select the zone including the group from the zone tree area. The operation statuses for all the groups included in the selected zone appear. In the Icon Display Mode In the main display area, information on the Start/Stop state, temperature setting, and error status for the selected zone or group is provided. About Zone: If one or more groups in the selected zone are operational, the Start/Stop state for the zone is On. If one or more groups in the selected zone are in an error state, the operation state for the zone is Error. If one or more groups in the selected zone have an illuminated filter/element sign, the filter/element sign for the zone also illuminates. An illuminated Auto Control sign informs that the selected zone is associated with one or more schedule programs. In the air conditioner zone area, information on the room temperature, setpoint, operation mode, air volume, and direction of air flow is provided. In the HRV zone area, information on the Ventilation mode, Ventilation amount, and Freshen up function is provided. Data of the representative unit is displayed, rather than that of the entire zone. For more information on the zone representative unit is follow on. CAUTION Zone representative unit In a zone monitoring process, the following group is selected as the representative unit. In the Icon display mode: the group displayed at the upper left corner In the List display mode: the top group in the list. For zones including HRVs For zones including both air conditioner and HRV groups: Clicking the tab displays status data of HRVs. For the purpose of status indication in the zone setting area, data of the representative unit is displayed, rather than that of the entire zone. The HRV group displayed at a higher position than any other HRV groups is selected as the representative unit. English 21
23 6. ADVANCED MODE 6-1 Main Screen This section provides the description of the Main screen for the Advanced mode. When logging into the application in the Advanced mode, the following screen is displayed. (4) (5) The above figure shows the Main screen displayed in the Icon display mode. (4) The figure to the left shows the Main screen displayed in the List display mode. In the List display mode the area (5) is not provided. 22 English
24 Display Areas on the Main Screen Zone tree area: When you select a zone in this area, devices included in the zone appear in the main display area. When logging into the web interface as a General User, the item Schedule or Proportional distribution does not appear. Main display area: Displays devices in the zone selected in the zone tree area. Also setting functions related to the zone is provided. In the Icon display mode, the icons set in the intelligent Touch Controller console are used. 6-2 Starting/Stopping All the Devices in a Specific Group Procedure for starting/stopping all the devices in a specific group Start or stop all the air conditioners included in a specific group. Procedure 1.On the Main screen (Screen 1) select the zone which includes a desired group from the zone tree area on the left side of the screen. Screen 1: Main screen System status display area: Displays the system status such as Compulsory Stop (Forced Stop) Mode. (4) Login name display: Displays the login name of the user currently logging into the web interface. (5) Status display area in the Icon display mode: Provides device status information. This bar is displayed only in the Icon display mode. Action Buttons Changes the main display area to the Icon display mode. Changes the main display area to the List display mode. Starts all the air conditioners for which the login user has an operation privilege. (See page 24) Stops all the air conditioners for which the login user has an operation privilege. (See page 24) Starts all the devices included in the selected zone or group. (See page 23 to 24) Stops all the devices included in the selected zone or group. (See page 23 to 24) Launches a dialog box displaying detailed information on the selected zone or group. (See page 31) 2.Groups assigned to the selected zone appear in the main display area. Select the group in this area. 3.Click the or button. 6-3 Starting/Stopping All the Devices in a Specific Zone Procedure for starting/stopping all the devices in a specific zone Simultaneously start or stop all the devices in air conditioner groups assigned to a zone. Procedure 1.Select the Monitoring (Zone list) item from the zone tree area in the Main screen (Screen 1). Screen 1: Main screen Launches a dialog box where you can set up the selected zone or group. (See page 24) Launches a dialog box describing detailed information on items displayed in the Icon/ List display modes. (See page 30) Returns to the screen specified by the previous zone tree setting. You can return to the screen up to 20 generations (maximum). Undoes your return operation. Updates zone or group status information in the main display area with the most recent data of the intelligent Touch Controller. Allows users to log off and returns to the login authentication screen. English 23
25 2.A zone list is displayed in the main display area. Select a desired zone in this area. Screen 1: Main screen 3. Click the or button. 6-4 Starting/Stopping Air Conditioners All Together Procedure for starting/stopping air conditioners all together Start or stop all of the registered air conditioners all together. This procedure supports both the Icon and List display modes. In the figure (Screen 1) the devices are displayed in the Icon display mode. Screen 1: Main screen The operation mode can be switched by zone or by group. Procedure 1.To change the setting for all the devices in a zone, select the Monitoring (Zone list) item from the zone tree area on the left of the screen, and select the zone from the main display area. To change the setting for all the devices in a group, select the zone including the group from the zone tree area, and select the group from the main display area. 2.Press the. Screen 2 Operation is displayed. Procedure Screen 2: Settings screen 1. Click the or button. CAUTION In the bulk start/stop operation, only the devices for which the login user has operation privileges are started or stopped but if the login user is the Administrator, all the devices are started or stopped. See page 5 for more information on permissions of the web interface. 6-5 Switching the Operation Mode Procedure for switching the operation mode Switch the operation mode of the air conditioner. On the Monitoring screen, operation is allowed with either Icon or List as the display type. In the figure (Screen 1) the devices are displayed in the Icon display mode. (4) 3.Select the Set checkbox in the Operation mode frame. Check one of the radio buttons (4) to select a desired operation mode. On the menu, operation modes available for air conditioners in the zone are displayed if the switching is to be made by zone. See the example on the next page. 24 English
26 4. Press the. 2.Press the. Screen 2 Operation is displayed. To cancel the setting, press the. Screen 2: Settings screen Ex.: For the zone of the figure 1 you can set the operation mode to Fan, Cool, Heat, Dependent, or Auto. When one or more air conditioners in the zone do not have Cool/Heat option, you can select only Fan or Dependent mode. Figure 1 Canteen 1F North [Dependent] [Fan] 1F West [Cool] [Heat] [Auto] [Fan] 6-6 Changing the Temperature Setting Procedure for changing the temperature setting Change the temperature setting of air conditioners. On the Monitoring screen, operation is allowed with either Icon or List as the display type. In the figure (Screen 1) the devices are displayed in the Icon display mode. Screen 1: Main screen (4) 3.Select the Set checkbox in the Setpoint frame, and set the integral and decimal parts using the pull-down menus (4). In a zone setting, the pull-down menus are pre-populated with allowable temperature values for the air conditioners in the zone. See the following example: 4.Press the. To cancel the setting, press the. Ex.: For the zone setting in the figure 1, the temperature settings available are between 20 C and 30 C inclusive. Figure 1 The temperature setting can be switched by zone or by group. When all the air conditioners in the selected group or zone are in the Fan mode, the temperature setting cannot be changed. Procedure 1.On Screen 1 Monitoring, select a zone or a group from the pull-down menu. Select a zone or a group of which the temperature setting is to be changed. To change the setting for all the devices in a group, select the zone including the group from the zone tree area, and select the group from the main display area. Zone name Group name Range of temperature settings available (see NOTE) Canteen 1F North 25 C - 30 C 1F West 20 C - 25 C When the temperature setting is 30 C, the actual temperature settings for air conditioners are as shown in the figure 2. Figure 2 Zone name Group name Range of temperature settings available (see NOTE) Canteen 1F North 30 C 1F West 25 C NOTE Range of temperature settings available are as follows: Range of temperature settings inherent to the air conditioner main unit. Range of temperature as a result of the restriction by temperature setting limit set on the intelligent Touch Controller console. For more information refer to the intelligent Touch Controller manual. English 25
27 6-7 Resetting Filter/Element Signs Procedures for resetting filter signs When one or more air conditioner provide filter/element signs, clean the specified filters or elements, and then reset the filter/ element sign. This procedure supports both the Icon and List display modes. In the figure (Screen 1) the devices are displayed in the Icon display mode. 2.Press the Screen 2: Settings screen. Screen 2 Operation is displayed. Screen 1: Main screen 3.Select the Reset checkbox in the Filter sign frame. You can reset all the signs displayed on air conditioners in a group or zone all together. Procedure 1.On Screen 1 Monitoring, select a zone or a group from the pull-down menu. Select a zone or a group of which the temperature setting is to be changed. To change the setting for all the devices in a group, select the zone including the group from the zone tree area, and select the group from the main display area. 4.Press the. To cancel the setting, press the. CAUTION In a zone setting, if one or more devices in the zone do not provide the filter/element sign, the Reset checkbox is grayed out. 26 English
28 6-8 Changing the Direction of Air Flow and Air Volume Procedure for changing the direction of air flow/air volume Change the air direction or volume of air conditioners. On the Monitoring screen, operation is allowed with either Icon or List as the display type. In the figure (Screen 1) the devices are displayed in the Icon display mode. Screen 1: Main screen 3.When setting the air volume, select the Set checkbox in the Air volume frame, and check one of the radio buttons to select desired air volume. When setting the direction of air flow, select the Set checkbox in the Air Direction frame (4) and select your desired value using the pull-down menu. Any integer value from 0 to 7 can be selected. 4.Press the. To cancel the setting, press the. Guideline for determining the direction of air flow and air volume 0 Indoor unit : Auto Swing mode Selecting a higher number results in a more vertical direction. The value 7 indicates the Auto Swing mode. However some models may not support this setting. Check the direction of air flow displayed on the local remote controller screen after setting. The air direction or volume can be changed by zone or by group. Procedure 1.On Screen 1 Monitoring, select a zone or a group from the pull-down menu. Select a zone or a group of which the air direction or volume is to be reset. To change the setting for all the devices in a group, select the zone including the group from the zone tree area, and select the group from the main display area. 6-9 Changing the HRV settings Procedure for changing the HRV settings Change HRV settings. On the Monitoring screen, operation is allowed with either Icon or List as the display type. In the figure (Screen 1) the devices are displayed in the Icon display mode. Screen 1: Main screen 2. Press the. Screen 2 Operation is displayed. Screen 2: Settings screen (4) You can change settings of all the HRVs included in a zone or group all together. English 27
29 Procedure 1.On Screen 1 Monitoring, select a zone or a group from the pull-down menu. Select a zone or a group of which the air direction or volume is to be reset. To change the setting for all the devices in a group, select the zone including the group from the zone tree area, and select the group from the main display area. 2. Press the. Screen 2 Operation is displayed. Screen 2: Zone Settings screen When Selecting an HRV Group When selecting an HRV group, the Group Settings screen (Screen 4) is displayed. This dialog box offers the following items: (7) (8) Screen 4: Group Settings screen (9) (10) (11) (12) When Selecting a Zone Including HRVs When selecting a zone including HRVs, the Zone Settings screen (Screen 2) is displayed. Click the button to display the HRV settings screen (Screen 3). You can set up the following two items. (4) (5) Screen 3: HRV settings screen (4) Ventilation mode In this frame the Ventilation mode can be changed. Select the Set checkbox, and check a desired radio button. (5) Ventilation amount In this frame the Ventilation amount setting can be changed. Select the Set checkbox, and check a desired radio button. Upon completion, click the button (6) and return to the Main screen. (6) (7) Current Condition Displays the current HRV status. The following four data items are provided. Start/Stop state Ventilation mode Ventilation amount Filter sign (8) Start/Stop In this frame you can start or stop the devices. Select the Set checkbox and check a desired radio button. (9) Ventilation mode In this frame you can select a Ventilation mode. Select the Set checkbox and check a desired radio button. (10)Ventilation amount In this frame you can select a Ventilation amount setting. Select the Set checkbox and check a desired radio button. (11)Filter sign When the Reset indicator is not grayed out, one or more filter signs illuminate. In Screen 2 the indicator shows that no sign illuminates. To reset the filter signs, select the Reset checkbox. (12)R/C Enable/Disable (Start/Stop) In this frame you can permit or prohibit the start/stop operation through remote controllers. Select the Set checkbox and check a desired radio button. Upon completion, click the button on each screen and return to the Main screen. CAUTION Some HRV models may not support the Freshen up or Ventilation amount setting options. In this case unavailable buttons are grayed out Permitting/Prohibiting Remote Controller Operations Procedure for permitting/prohibiting remote controller operations Permit or prohibit operations through remote controllers. On the Monitoring screen, operation is allowed with either Icon or List as the display type. See next page in the figure (Screen 1) the devices are displayed in the Icon display mode. 28 English
30 Screen 1: Main screen 3.The area under the R/C Enable/Disable heading includes three frames to permit/prohibit operations through remote controllers. Select the Set checkbox in each frame to set. Start/Stop Permitted Stop Only Prohibited R/C Op. Mode Permitted or Prohibited R/C Setpoint Permitted or Prohibited 4.Upon completion, click the button. To cancel your settings, click the button Monitoring Operations of All the Devices in a Specific Zone or Group Procedures for monitoring zone or group operations Monitor operations in both the Icon and List display modes. Select a display mode using the or button. You can change the settings of all the devices included in a group or zone. Procedure 1.On Screen 1 Monitoring, select a zone or a group from the pull-down menu. Select a zone from a main display area to be changed. To change the setting for all the devices in a group, select the zone including the group from the zone tree area, and select the group from the main display area. Operations can be monitored by zone or by group. Screen 1: Main screen (Icon display mode) 2.Press the is displayed.. Screen 2: The Zone Settings screen Screen 2: Settings screen (4) To monitor operations of devices in a zone, select the Monitoring (Zone list) item from the zone tree area. The operation status is displayed in the main display area. To monitor operations of devices in a group, select the zone including the group from the zone tree area. The operation statuses for all the groups included in the selected zone appear. (4) (5) For an HRV group setting, see the previous page. English 29
31 Displayed Items in the Icon Display Mode You can monitor the Start/Stop state and presence or absence of error, Auto Control setting, and filter/element sign for each group or zone in the main display area. In the Icon display mode, the bottom bar in the Screen 1 displays information on the selected zone or group. The following information is offered. The frames ((4) in the Screen 1 and 2) at the lower right corner show legend. Screen 2: Main screen (Icon display mode) When all the devices operate normally Temperature setting For a zone, the operation mode of the representative unit is shown. Operation mode For a zone, the temperature setting of the representative unit is shown. Group name For a zone, the zone name is shown. When any of the devices failed Error code For a zone, the error code that explains the status of the failed device is shown. Group name For a zone, the zone name is shown. For more information on the representative unit, see the figure to the right. Displayed Items in the List Display Mode In the main display area the following zone or group information is displayed. Start/Stop state For a zone, see the following section. Presence/absence of error For a zone, see the following section. Presence/absence of Auto Control setting For a zone, see the following section. Presence/absence of filter/element signs For a zone, see the following section. Temperature setting For a zone, the temperature setting of the representative unit is shown. Operation mode For a zone, the operation mode of the representative unit is shown. Room temperature For a zone, the room temperature of the representative unit is shown. Error code For a zone, the error code that explains the status of the failed device is shown. To see the detailed legend information shown in the Screen 3, click the button. Screen 3: Legend screen To return to the Main screen, click the CAUTION 1 button. Representative unit: In a zone monitoring process, the following group is selected as the representative unit. In the Icon display mode: the group displayed at the upper left corner In the List display mode: the top group in the list. (4) 30 English
32 Notes on Zone Display If one or more groups in the selected zone are operational, the Start/Stop state for the zone is On. If one or more groups in the selected zone are in an error state, the operation state for the zone is Error. If one or more groups in the selected zone have an 2.Click the button. The Details screen (Screen 2) is displayed and provides the following data items. Screen 2: Details screen illuminated filter/element sign, the filter/element sign for the zone also illuminates. An illuminated Auto Control sign informs that the selected zone is associated with one or more schedule programs. In the air conditioner zone area, information on the room temperature, setpoint, operation mode, air volume, and direction of air flow is provided. In the HRV zone area, information on the Ventilation mode, Ventilation amount, and Freshen up setting is provided. Data of the representative unit ( CAUTION 1 ) is displayed, rather than that of the entire zone Monitoring Detailed Information Procedures for monitoring detailed information Detailed operation status can be monitored by zone or by group. Screen 1: Main screen Procedure 1.To view details on a zone, select the Monitoring (Zone list) item from the zone tree area. To view details on a group, select the zone including the group from the zone tree area. Then select the target zone or group in the main display area. [For an air conditioner group] 1) Name : Group name 2) Description : Group description 3) Type : Air conditioner or device 4) Group Addr : Address between 1-00 and ) Schedule : Enable/Disabled 6) Heating Optimization : Enabled/Disabled 7) Temperature Limit : Enable/Disable 8) Automatic Changeover : Enable/Disable 9) Simple Interlock : Enable/Disable 10) R/C : Main/Sub 11) Changeover Option : Able/N/A 12) OD-Unit Addr : Address of outdoor unit 13) Err Code : Error code 14) Err Unit No. : Error unit number NOTE Neither Err Code nor Err Unit No. are displayed under a normal operation. [For a zone] 15) Name : Zone name 16) Description : Zone description 17) Sequential Start : Enabled/Disabled 18) Interval : Interval when Enabled is set for the above 19) No. of Regist Grp : Numbers of registered groups 20) Schedule : Enabled/Disabled Click the button to return to the Main screen. On the Details screen for HRV groups, items 1), 2), 3), 4), 5), and 10) (plus 13) and 14) in an error state) are displayed. For Dio groups, items 1), 2), 3), 4), and 10) (plus 13) and 14) in an error state) are displayed. For Di groups, items 1), 2), 3), and 4) (plus 13) and 14) in an error state) are displayed. English 31
33 3.Click the button on the previous page to display the following Error History screen (Screen 3). In this screen you can check errors that the selected devices have encountered. If no error has occurred, the Screen 4 is displayed. 2.Click the button to display the Settings screen (Screen 2). This screen provides the following information. Screen 2: Settings screen Screen 3: Error History screen Screen 4: Error History screen (4) Click the button to return to the Details screen. (5) Error event information including the time it occurred, error code, and error unit number are recorded and sorted by time occurred. Up to 10 historical error events can be recorded. When an error event with the same error code as one for the already registered event occurs in a specific group, only the time is updated. For a specific group two or more error events with the same error code are not registered Monitoring Detailed Operation Status Procedure for monitoring detailed operation status Detailed operation status can be monitored by zone or by group. Screen 1: Main screen (6) (7) Name (Description) Displays the name and description of a zone or group. Current Condition Start/Stop state Operation Mode Air volume Displays current air volume. (4) Direction of air flow Displays current direction of air flow. (8) Room temperature Presence or absence of filter signs The area under the R/C Enable/Disable heading includes three frames to display the setting for permission/prohibition of operation through remote controller. In each frame one of the following options is highlighted: (5) Start/Stop Permitted Stop Only Prohibited (6) R/C Op. Mode Permitted or Prohibited (7) R/C Setpoint Permitted or Prohibited Procedure 1.To view information on a zone, select the Monitoring (Zone list) item from the zone tree area. To view information on a group, select the zone including the group from the zone tree area. Then select the target zone or group in the main display area. 3.Upon completion, click the the Main screen. (8) button to return to CAUTION This screen can be used for both setting and monitoring. When using it only for monitoring, be sure to click the button, rather than the to close it. This prevents you from inadvertently changing existing settings. 32 English
34 6-14 Monitoring Operation Status of HRVs Procedure for monitoring HRV operation The operation of all the HRVs can be monitored by zone or by group. Screen 1: Main screen When Monitoring a Zone of HRVs When selecting a zone including HRVs, the Zone Settings screen (Screen 2) is displayed. Click the button to display the HRV settings screen (Screen 3). Screen 3: HRV settings screen (4) (5) (6) You can view the following two items. (4) Ventilation mode Displays the current Ventilation mode. (5) Ventilation amount Displays the current Ventilation amount. Procedure 1.To view information on a zone, select the Monitoring (Zone list) item from the zone tree area on the left side of the screen. To view information on a group, select the zone including the group from the zone tree area. Then select the target zone or group in the main display area. 2. Press the button. Screen 2 Operation is displayed. Screen 2: Zone Settings screen Upon completion, click the (6) button to return to the Main screen. When Monitoring a Group of HRVs When selecting an HRV group, the Group Settings screen (Screen 4) is displayed. You can view the following items in this screen: Screen 4: Group Settings screen (7) (8) (7) Current Condition Start/Stop state Ventilation mode Ventilation amount Filter sign (8) R/C Enable/Disable (Start/Stop) Displays the setting for permitting/prohibiting start/stop operations through remote controllers. Upon completion, click the to return to the Main screen. button on each screens CAUTION This screen can be used for both setting and monitoring. When using it only for monitoring, be sure to click the button, rather than the to close it. This prevents you from inadvertently changing existing settings. English 33
35 7. ABOUT SYSTEM SETTINGS MENU 7-1 Overview The System Settings menu is provided in the zone tree area displayed in the Advanced mode. This menu provides the following menu items. System setting menu Password Setting Propriety of operation by login authority Administrator General User System Settings Registration of General Users Deletion of General Users Assigning Zones to General Users Creating Schedules Proportional distribution settings The following table explains these privileges (System Settings menu items). System setting Menu Name Password Setting Registration of General Users Deletion of General Users Assigning Zones to General Users Overview: Schedule Creation Procedure Description Each General User can change his/her own login password. The Administrator can change not only his/her own login password but also registered General Users login passwords. The Administrator can register General Users using this menu item. Registered General Users can operate air conditioners and other devices through the web interface. Up to 64 General Users can be registered. : Granted : Denied Reference See page [38] See page [39] The Administrator can delete any of the registered General Users. See page [40] The Administrator can assign one or more zones to each General User. The General User can operate devices included in these zones. Zones are created in advance using the intelligent Touch Controller console. It is impossible to create a zone via the web interface. The Schedule menu item allows you to create operation schedules and link it to one or more zones or groups. You can automatically start/stop air conditioners at a point in time. The time value (Year, Month, Day, Day of week, Hour, Minute) is set in advance on the intelligent Touch Controller according to the usage of the air conditioners. The options provided for creating schedule events are: Start/Stop Permitting/prohibiting local remote controller operations Operation mode Ventilation mode ( ) Setting temperature Ventilation amount ( ) ( ) Only for HRVs The following describes the steps required to make a plan to create scheduling patterns. There are two types of schedule patterns: 7 regular schedule patterns (applied to Sun to Sat) and 10 extra schedule patterns (Ex1 to Ex10). To get things started, make a plan for creating these 17 schedule patterns on the Calendar Setting Table and write down your plan. Do the setting of Calendar Setting, Weekly Setting, Extra Schedule Patterns. Ex.: Regular schedule patterns are for normal business days and extra schedule patterns are for a special period such as summer holidays. You can create schedule programs for the next 13 months. Finally assign events to the above 17 schedule patterns (regular schedule patterns: Sun to Sat; extra schedule patterns: Ex1 to Ex10). Ex.: Starts devices in zone 1 at 9:00 and stops at 17:00 Up to 16 operations can be set for each day. Up to 8 schedule programs can be set, by concerning the schedules above as one. See page [40] See page [41] 34 English
36 Zone Setting Schedule Calendar Setting The following section provides a setting example. 1. [Floor usage] 1F: Reception counter Names this Zone 1F. 2F: Office Names this Zone 2F. 3F: Canteen Names this Zone 3F. 2. Information required to create the schedule for each zone is recorded on the Calendar Setting Table. Each column corresponds to a zone and each row corresponds to a schedule pattern (for each day of the week and extra schedule days). Zone name Day of week Zone 1F Zone 2F Zone 3F SUN Holiday Holiday Holiday Ex1 Ex2 Ex3 Ex4 MON 9:30-18:00 Duty hours 8:30-17:00 Duty hours 12:00-13:00 Lunch break 17:00-22:00 Overtime hours 22:00 Closing office TUE ditto ditto ditto WED 9:30-17:00 Duty hours ditto ditto THU same as Mon ditto ditto FRI same as Mon ditto ditto 9:00-14:30 Duty hours SAT Holiday Holiday Holiday third Sat of every month 1st Aug to 20th Aug 29th Dec to 4th Jan 28th Dec 5th Jan Concerned as a working day Concerned as a working day Holiday Holiday Holiday 9:00-12:00 Service hours 10:00-15:00 Service hours 9:00-12:00 Service hours 9:00-12:00 Service hours 12:00-13:00 Lunch break Concerned as a working day Holiday 9:00-14:30 Duty hours English 35
37 System setting Menu Name Determining Schedule Events Example: Scheduling 3. In this step you will determine schedule events for Zone 2F. Note: These events are provided only for reference. Create customized schedules based on your actual requirements. Example: event settings for Mon to Fri Time Target Zone Start/Stop Operation mode Setpoint Remote Controller Code 8:30 Zone 2F ON Null Null Override 12:00 Zone 2F OFF Null Null Null 13:00 Zone 2F ON Null Null Override 17:00 Zone 2F Null Null Null Permits only stopping 22:00 Zone 2F OFF Null Null Prohibits remote controller operations Example: event settings for Sat and Sun Time Target Zone Start/Stop Operation mode Setpoint Remote Controller Code 9:00 Zone 2F Null Null Null Override 17:00 Zone 2F OFF Null Null Prohibits remote controller operations Example: event settings for Ex1 (third Sat of each month) Time Target Zone Start/Stop Operation mode Setpoint Remote Controller Code 8:30 Zone 2F ON Null Null Override 12:00 Zone 2F OFF Null Null Null 13:00 Zone 2F ON Null Null Override 17:00 Zone 2F Null Null Null Permits only stopping 22:00 Zone 2F OFF Null Null Prohibits remote controller operations Example: event settings for Ex2 (for example, summer holidays) Time Target Zone Start/Stop Operation mode Setpoint Remote Controller Code 9:00 Zone 2F Null Null Null Override 17:00 Zone 2F OFF Null Null Prohibits remote controller operations Example: event settings for Ex3 (M. 12 D. 28) Time Target Zone Start/Stop Operation Setpoint mode 9:00 Zone 2F ON HEAT 25 C Example: event settings for Ex4 (M. 1 D. 5) Remote Controller Code Override Prohibits temperature setting Prohibits operation mode setting 12:00 Zone 2F OFF Null Null Prohibits remote controller operations Time Target Zone Start/Stop Operation mode Setpoint 10:00 Zone 2F ON HEAT 25 C Remote Controller Code Override Prohibits temperature setting Prohibits operation mode setting 12:00 Zone 2F OFF Null Null Null 13:00 Zone 2F ON Null 25 C Override Prohibits temperature setting Prohibits operation mode setting 15:00 Zone 2F OFF Null Null Prohibits remote controller operations Null indicates that the previous state is maintained in the time frame. Reference See page [43] See page [45] Copying or Deleting Schedule Programs Copying or Deleting Schedule Events You can copy or delete existing schedule programs. See page [47] You can copy or delete existing schedule events. See page [47] Naming a Schedule You can change a default schedule name to a descriptive one. See page [48] 36 English
38 System setting Menu Name Proportional distribution function Outline explanation Functional outline The proportional distribution calculation of the power consumption of each air conditioner is made, displayed, and output in files. This function makes it possible to measure the total power consumption of the air conditioners of facilities, such as a tenant building, with a meter and calculate the power consumption of each air conditioner on a tenant basis. Normal Type... The amount of power consumption can be divided proportionally. The function is available on the website if it is used together with the proportional distribution software as an optional application. The following web setting and control items of the proportional distribution function are available. <Setting items> Excluded Time (Normal Type) Special Calculation Days (Normal Type) <Control items> Setting/Display of collection result File output of collection result A procedure for proportional distribution control is explained below. Excluded Time (Normal Type) You can set the desired time zone between 0:00 and 24:00 and the day of the week for not performing proportional distribution calculation. Special Calculation Days (Normal Type) Proportional distribution calculation between 0:00 and 24:00 is possible for holidays (public holidays and national holidays) other than regular closing days (e.g., Saturdays and Sundays). You can set the desired time zone and day of the week in the exclusion period zone as well. Setting/Display of collection result Set the period to display the result of proportional distribution. The display of either the period or month is possible. File output of collection result You can save the result of proportional distribution calculation in CSV file format into the hard disk of the PC. For details, refer to the operation manual of the intelligent Touch Controller software. Reference See page [49] See page [50] See page [51] See page [54] English 37
39 7-2 System Settings This menu item provides the following functions: Changing passwords (This page and next page) Registration/deletion of General Users (See page 39 to 40) Assigning one or more Zones to each General User (See page 40) To Change Your Own Password 1.Log into the interface as the Administrator or a General User 2.Select the System Settings node from the zone tree area to display the System Settings main screen (Screen 1). Screen 1: System Settings main screen CAUTION Administrator passwords for web interface and console When a new Administrator password is set in this screen, it becomes the same password necessary to operate the System Console Menu. The new Administrator password replaces any prior Administrator password in the system. To Change a General User Password (When You are the Administrator) 1.Log into the interface as the Administrator, and select the System Settings node from the zone tree area to display the System Settings main screen (Screen 1). Screen 1: System Settings main screen 3.Double click the Password change icon to display the Modify Password screen. Screen 2: Modify Password screen 2.Double click the User settings icon to display the User settg dialog box (Screen 2). Screen 2: User settings dialog box (4) (5) 4.Enter the existing password into the current password field. If you have no password, skip this field. 5.Enter a new password into the New password field (4). Then enter the password again into the Checking new password field (5) for confirmation. These two fields accept up to 15 characters. 6. Upon completion, click the button. (4) 3.Select a user name from the User name list, and click button (4). Note that the admin item in the list represents the Administrator. 38 English
40 The Modify Password dialog box (Screen 3) is displayed. Screen 3: Modify Password screen 2.Double click the User settings icon to display the User setting dialog box (Screen 2). Screen 2: User settings dialog box (5) (6) 4.Enter a new password in the Password field (5) and re-enter the same password in the Confirm password filed (6) for confirmation. 5. Upon completion, click the button. To cancel your entry, click the button. NOTE You also can change the Administrator password in the User settings dialog box (Screen 2) by selecting admin rather than a user name in the step 3. Click the button (4). Then repeat the steps 4 and 5. To Register a General User 1.Log into the interface as the Administrator, and select the System Settings node from the zone tree area on the left side to display the System Settings main screen (Screen 1). Screen 1: System Settings main screen 3.Click the button to display the Add user dialog box where user name and password can be typed (Screen 3). Screen 3: Add user dialog box (4) (5) (6) 4.In the User name field, type the user name to be registered (4). 5.In the Password field, type a new password for the User (5) and re-type the same password in the Confirm password filed (6) to confirm. 6.Upon completion, click the button. To cancel your entry, click the button. English 39
41 To Delete a General User 1.Log into the interface as the Administrator, and select the System Settings node from the zone tree area to display the System Settings main screen (Screen 1). Screen 1: System Settings main screen Assigning Zones to General Users 1.Log into the interface as the Administrator, and select the System Settings node from the zone tree area to display the System Settings main screen (Screen 1). Screen 1: System Settings main screen 2.Double click the User settings icon to display the User settings dialog box (Screen 2). Screen 2: User settings dialog box 2.Double click the User settings icon to display the User settings dialog box (Screen 2). Screen 2: User settings dialog box (4) 3.Select the name of the user to be deleted from the User name list, and click the button to display the Deletion of user confirmation dialog box (Screen 3). Click the Yes button to confirm your selection. Screen 3: Confirmation dialog box (Deletion of User) 40 English
42 3.Select the zone you want to assign or remove and click the button. The Zone editing dialog box (Screen 3) is displayed. Screen 3: Zone editing dialog box 8. CREATING SCHEDULES 8-1 Main Scheduling Screen This section describes the components of the main scheduling screen. When selecting the Schedule node from the zone tree area, on the left side of the screen, the following Main Schedule screen is displayed. (8) (6) (9) (7) (4) (5) 4.Select a zone to be assigned to the selected user from the right list (5) and click the button (6). The zone is moved to the left list (4). To remove an assigned zone, select the zone from the left list (4) and click the button (7). The zone is removed from the list. 5.To change the order of items in the left list (4), use the (8) and (9) buttons. 6. Upon completion, click the button. To cancel your entry, click the button. Schedule node in the zone tree area Selecting this node displays the main scheduling screen. Schedule program list Lists the name and status (Enabled/disabled) for each schedule program. Enable/Disable radio buttons Displays the status of the program selected in the list. You can enable or disable it using these buttons. Displays the Schedule screen. For more information on the Schedule screen layout, see the next page. Displays the Edit Schedule screen. For the description of how to use this button, see the page 47. English 41
43 8-2 Schedule dialog box (5) (6) (7) (4) (8) Pattern radio buttons and Pattern bar A Pattern bar displays various operations to be performed for each day. Pattern radio buttons are used to select the schedule pattern to be edited. (See page 44) Changes schedule patterns. (See page 43) Copies or deletes schedule patterns. (See page 47) (4) Renames Ex schedule patterns. (See page 48) (5) Renames schedule programs displayed on the main scheduling screen. (See page 48) (6) Schedule Calendar area Renames schedule programs displayed on the main scheduling screen. (See page 46) (7) Legend area Describes the symbols representing each schedule pattern. (8) Used to assign one or more dates to an Ex schedule. (See page 46) 42 English
44 8-3 Using the Schedule Menu To edit a schedule program Procedure 1.Select the Schedule node from the zone tree area. Screen1: Main scheduling screen 8-4 Creating Regular Schedule Patterns To create regular schedule patterns 1.To create regular schedule patterns (Sun to Sat), select a target day of the week by clicking an appropriate pattern radio button. Screen1: Schedule screen 2.The schedule program list is displayed. You can create up to 8 schedule programs. Select the schedule program you want to set up or change, and click the button. 3.The Schedule dialog box (Screen 2) is displayed where you can set up or change the schedule program. Screen 2: Schedule screen 2.Click the button to display the Pattern change dialog box (Screen 2). Screen 2: Pattern change dialog box (4) (5) (6) (7) Screen 3: Target dialog box See the following pages for the instructions. Regular schedule pattern: (This page) Ex schedule pattern: (See page 45) English 43
45 3.To add a new schedule event, click the button. A new event item is displayed in the top row of the schedule event list (6). You can set up or change a new or existing event item in this list. 4.Select the new event added in the step 3 or an existing event, and set or change various variables of the event using options in the schedule event settings area (7). To set or change these variables, select the Set checkbox in each frame and click a desired radio button. In each frame below you can: Run time: Set a time value that indicates when the event should occur using the pull-down menus. Target: Set/change a target zone or group. Click the button to display the Target dialog box (Screen 3), where you can select a target group or zone. Start/Stop: Select an action (Start or Stop) that the event triggers using the radio buttons. R/C Setpoint: Set the temperature setting value for the selected zone or group using the radio buttons. Operation mode: Set the operation mode for the selected zone or group using the radio buttons. R/C Enable/Disable: Permit or prohibit the remote controller operation using the radio buttons. In each of the following three frames, you can: Start/Stop: Permit or prohibit the start/stop operation through remote controllers. Operation Mode: Permit or prohibit the modification of the operation mode through remote controllers. R/C Setpoint: Permit or prohibit the modification of the temperature setting through remote controllers. Ventilation mode: Set the HRV s ventilation mode using the radio buttons. Ventilation amount: Set the HRV s ventilation amount. CAUTION When the devices in the target group or zone are not HRVs or HRVs that do not support these settings, your selection will be ignored even if the Set checkbox is selected. 5.Upon completion, click the change dialog box (Screen 2). To cancel your selection, click the button on the Pattern button. Return to the Schedule screen (Screen 1 of the previous page). You will confirm your settings on this screen. Other Buttons (4) Deletes the event item selected in the schedule event list (6). (5) Screen 2: Pattern change dialog box (5) (4) Duplicates a selected event item in the schedule event list (6). 6.In the Schedule screen the schedule pattern bar in the figure (Screen 4) is displayed. Each mark represents: Screen 4: Pattern bar Screen 5: Example of pattern bars 9 : 00 Starts 12 : 00 Changes temperature setting 15 : 00 Stops (6) (7) 9 : 00 Starts 9 : 15 Changes temperature setting 12 : 00 Changes temperature setting 15 : 00 Stops 9 : 00 Starts 9 : 30 Changes operation mode 12 : 00 Changes temperature setting 15 : 00 Stops 44 English
46 (Red): Start event (Green): Stop event (Black): Event other than start/stop events The marks on the bar indicate the time frame (half-hour unit, for example: 0:00 to 0:29, 0:30 to 0:59) within which the event should occur. See the examples in the Screen 5. If the setting is satisfactory, click the button. Return to the main scheduling screen (Screen 6). Screen 6: Main scheduling screen 8-5 Creating Ex Schedule Patterns To create Ex schedule patterns 1.You can also create 10 extra schedule patterns (Ex1 to 10) in the Schedule screen (Screen 1). Click an appropriate radio button to select the Ex schedule pattern to be set up or changed. Screen 1: Schedule screen 2.Click the dialog box (Screen 2). button to display the Pattern change Screen 2: Pattern change dialog box (4) (5) 7.In this screen you can enable the schedule program just created. By default it is disabled. Click the Enable radio button to enable it. (6) CAUTION Disabled schedule programs do not work. The regular schedule patterns are now created. (7) 3.To add a new schedule event, click the button. A new event item is displayed in the top row of the schedule event list (6). You can set up or change a new or existing event in this list. 4. Select the new event added in the step 3 or an existing event, and set up or change various variables of the event using options in the schedule event settings area (7). To set up or change these variables, select the Set checkbox in each frame and click a desired radio button. For the description of the setting options, see the Creating Regular Schedule Patterns section. English 45
47 5. Upon completion, click the button on the Pattern change dialog box (Screen 2). To cancel your entry, click the button. Return to the Schedule screen (Screen 1). 6. Repeat the steps 1 to 5 in this procedure if other extra schedule patterns should be set up. 7. In the Schedule screen the schedule pattern bar in the figure (Screen 3) is displayed. For the description of each mark, see the Creating Regular Schedule Patterns section. 9. The Calendar change screen (Screen 2) is displayed. Click the Set checkbox. Screen 2: Calendar change screen Screen 3: Pattern bar If the setting is satisfactory, associate each Ex schedule pattern with a specific date. See the following (Screen 1). 8. Then mark the dates on the calendar to indicate when the Ex schedule events should occur. As shown in the figure, by default no Ex schedule is associated. Regular schedule patterns are applied to all the dates. Screen 1: Schedule screen Click the button. 10. Click the appropriate radio button to select the Ex schedule pattern to be set. 11. With the Ex schedule pattern radio button selected, click a date on the calendar to assign that date to the Ex schedule pattern. To deselect an Ex-schedule-pattern-assigned date, select the Week radio button and then click the date. 12. Upon completion, click the button to return to the main scheduling screen. In this screen you can enable the schedule program just created. By default it is disabled. Click the Enable radio button to enable it. CAUTION Disabled schedule programs do not work. The extra schedule patterns are now created. 46 English
48 8-6 Copying or Deleting a Schedule Program To copy or delete a schedule program 1.Click the button in the main scheduling screen (Screen 1). Screen 1: Main scheduling screen Deletion Procedure Select the schedule program to be deleted in the right list and then choose a deletion option from the pull down menu (4). The following options are provided. All settings are deleted. Only the calendar setting is deleted. Click the button (5). Then click the button to complete the copy process. 8-7 Copying or Deleting Schedule Events To copy or delete schedule events 1.Click the (Screen 1). button in the Schedule screen Screen 1: Schedule screen 2. The Edit Schedule screen (Screen 2) is displayed. Screen 2: Edit schedule screen (4) (5) 2.The Edit Schedule screen (Screen 2) is displayed. Screen 2: Edit Schedule screen Copy Procedure Select a source schedule program in the left list and a target schedule program in the right list. In the example (Screen 2) the items of the Schedule 1 are copied to the Schedule 2. Then select a copy option in the pull down menu (4). The following options are provided All settings are overwritten. Only the calendar setting is overwritten. (4) (5) Click the button (5). Then click the button to complete the copy process. English 47
49 Copy Procedure Select a source date in the left pull down menu and a target date in the right pull down menu. The following two copy options are provided. 1) To Copy All the events of the target date with ones of the source date, click the button. 2) To insert an event selected in the left list (4) into the right list (5), select appropriate events and click the button. 2.The Edit Schedule screen (Screen 2) is displayed. Screen 2: Schedule screen Deletion Procedure Select the date including the event to be deleted in the right pull down menu. Then choose the target event from the events displayed in the right list (5) and click the button. 3. Then click the button to complete the copy process. (4) 8-8 Naming a Schedule Program To name a schedule program 1.Select the schedule program to be named in the list on the main scheduling screen (Screen 1), and click the button. Screen1: Main scheduling screen Click the button. 3.The Name Change dialog box (Screen 3) is displayed. Enter a name into the field of this box. Up to 16 characters can be entered. Screen 3: Screen 4: 4.Click the button to complete this process. 5.To name an Ex schedule pattern, select the Ex schedule pattern from the list on the Schedule screen (Screen 2), and click the button (4). 6.The Name Change dialog box (Screen 4) is displayed. Enter a name into the field of this box. Up to 16 characters can be entered. 7.Click the button to complete this process. 48 English
50 8-9 Menu Structure of Proportional Distribution Function This page explains the screen displayed when the schedule menu is selected. When Pwr Details Dist is selected, the following Main screen for proportional distribution is displayed. Screen1: Main screen for proportional distribution You can set the desired calculation date of the collection month of proportional distribution. Set the desired time zone and the day of the week for not performing proportional distribution calculation. (4) Proportional distribution calculation is possible for holidays (public holidays and national holidays) other than regular closing days (e.g., Saturdays and Sundays). (5) You can set the collection result list of proportional distribution data on an indoor unit basis. You can set the collection result list of proportional distribution data on a zone basis Display Area Zone tree are When Pwr Details Dist is selected, the Main screen for proportional distribution is displayed. Total result list The collection result of proportional distribution is distributed as a list. Period The collection period of proportional distribution is displayed. (4) Start date The start date of the collection period of proportional distribution is displayed. (5) End date The end date of the collection period of proportional distribution is displayed Buttons The display of the total of the collection result list of proportional distribution data. You can save the result list of proportional distribution data in CSV file format on the hard disk of the PC. When downloading proportional distribution data, make sure that the Locale language for the intelligent Touch Controller is the same as the language for the Windows version running on the PC. If the Locale language is different, the characters in the proportional distribution data may be garbled. (See 4-5 Selecting Display Language) Press this button to return to the previous screen displayed in the zone tree. You can return to a maximum of 20 screens. Proportional distribution data on the period or month set is collected and distributed in the collection result list in the display area. Press the zone tree. button to advance the screen displayed in the You can select the desired set period of proportional distribution. When the Set period radio button is selected, the Month radio button is grayed out. You can set the start and end dates of the collection of proportional distribution. You can select the desired month of proportional distribution. When the Month radio button is selected, the Set period radio button is grayed out. Press this button to log off and return to the login screen Settings for Excluded Time (Normal Type) You can set the desired time zone between 0:00 and 24:00 and the day of the week for not performing proportional distribution calculation. Example You can use this screen if you want to collect a fixed amount charge for normal business hours on weekdays and calculate the proportional distribution of power consumption only for overtime and holidays. English 49
51 You can make exclusion period settings on a time zone basis (between 0:00 and 24:00) or on a day-of-the-week basis. These settings are made for the whole system, and you can make individual settings on a group or zone basis. 1.Press screen (Screen 1) for proportional distribution. Screen 2 for Excluded Time is displayed. Screen 1: Main screen for proportional distribution in the Main 6.Press (4) on completion of the settings. Press (5) to cancel the settings. The Main screen (Screen 1) for proportional distribution is displayed Setting Special Calculation Days (Normal Type) Take the following steps to set special calculation days. It is possible to make exceptional settings so that you can make the proportional distribution calculation of the already-set exclusion period of any full day (i.e., 0.00 to 24:00) of the week. Example You can make the above exceptional settings if you want to make the proportional distribution calculation of the 24-hour periods of specified holidays (public holidays and national holidays), other than regular closing days (e.g., Saturdays and Sundays). You can make settings on a year basis, and the month and date that are set will be valid in the next year as well. If settings are made for February 29 of a leap year, the same setting will be effective on February 29 in the next leap year. This function has a setting range up to December Press in the Main screen (Screen 1) for proportional distribution. Screen 2 for special calculation days is displayed. Screen 1: Main screen for proportional distribution Screen 2: Screen for Excluded Time (4) (5) 2.Set the desired day of the week for the target exclusion period. Check the corresponding radio button in the Enable/Disabled field. The start time and ending time appear in the Start/Ending time field. 3.Press the buttons for the start time and ending time and set the period. Check that the set start time and ending time are displayed in the Start/Ending time field. 4.If you want to disable any exclusion period already set, select the corresponding day of the week and press the Disabled radio button in the Enable/Disabled field. The Start/Ending time filed is grayed out and the settings are disabled. 5.If you want to make an exclusion period for a different day of the week, repeat steps 2 and 3 of the above. Go to step 6 to finish the settings. 50 English
52 Screen 2: Screen for special calculation days If the Month radio button is selected in the collection field, the collection start date, end date, and modify buttons are grayed out. Screen 1: Main screen for proportional distribution (8) (4) 2.Press or to select the desired month to be set. 3.Select the desired special calculation day of the month in the calendar field. When the date is selected, a square is displayed around the date. If an exclusion period is set for any day, the day will be marked with an asterisk. 4.If you want to cancel the proportional distribution calculation of a particular day of the month, select the date in the Calendar field. The square box around the day disappears and the setting is canceled. 5.If you want to set another special calculation day, repeat steps 2 and 3 of the above. Go to step 6 to finish the settings. 6. Press on completion of the settings. Press (4) to cancel the settings. The Main screen (Screen 1) for proportional distribution is displayed Setting Collection Periods of Proportional Distribution Result (Period Settings) Period settings enable you to make arbitrary settings for the period collecting the result of proportional distribution. Example Use this function if you want to make a zone change or increase the number of air conditioners during a month and you want to see the proportional distribution results before and after the change or increment. The possible setting range of the start date is from the first day of the month of the previous year to the last day of the month and that of the end date is from the first day of the month of the previous year to the day before the last day of the month. 1.Select the Set period radio button from the collection field in the Main screen for proportional distribution (Screen 1). The collection start date and end date is displayed. Screen 2: Screen for collection start date (4) (5) (6) (7) Screen 3: Screen for collection end date (4) (5) (6) (7) English 51
53 2. Press to change the collection start date. Press to change the collection end date. When you select the collection start date, Screen 2 for the collection start day is displayed. When you select the collection end date, Screen 3 for the collection end date is displayed. 3.Select the collection start month or end month. Select the desired month with the or in Screens 2 or 3. If the change to the previous month is not possible, the is grayed out. If the change to the next month is not possible, the is grayed out. 4.Select the collection start date or end date. Select the date in the calendar field (4) in Screen 2 or Screen 3. The selected date is grayed out. 5.Check that the collection start date and end date in the Date filed (5) in Screens 2 and 3 are correct. If the selected date is incorrect or if you want to make changes, take steps 2 to 4 of the above. 6.Press (6) in Screen 2 and Screen 3 on completion of the settings. Press (7) to cancel the settings. The Main screen (Screen 1) for proportional distribution is displayed. Check that the start date and end date are properly set in the Start/End field (8). If they are incorrect, take steps 2 to 5 of the above. Screen 1: Main screen for proportional distribution Screen 2: Screen for calculation date 8-15 Setting Collection Periods of Proportional Distribution Result (with Month Specified) You can display the result of proportional distribution on a monthly basis with the desired month specified. By specifying the calculation periods, you can display the result of proportional distribution between the specified calculation dates of the previous month and the next month. Example You can use this function to see the result of power proportional distribution of in-building facilities (e.g., tenants). The collection period is from 0:00 of the specified calculation date of the previous month to the 0:00 of the specified calculation date of the present month. Example If the calculation date is set to 20 while the date displayed on the intelligent Touch Controller is October 20, the result of proportional distribution displayed covers a period from September 20 to October Select the Month radio button from the collection filed in the Main screen (Screen 1) for proportional distribution. The Calculation date combo box is displayed. If the Set period radio button is selected in the Collection field, the Calculation date combo box is grayed out. 2.Open the Calculation date combo box and set the target date. Refer to Screen 2 for calculation date. If the date settings are completed, check that the selected dates appear in the Calculation date field. This function has a setting range from the first day to 31st day of the month. If you set the calculation date to the 31st but the month has no 31st day, the calculation period will start from the end of the month. In the case of February, the calculation period will start February 28. In the case of a leap year, a total period will start February Display Method of Proportional Distribution Result-1 You can display and check the collection result of proportional distribution data in the list of the Collection result field. Moreover, you can save the result of proportional distribution in CSV format on the hard disk of the PC. If you select No in the security warning screen (see page 5), you cannot save the file on the PC hard drive. If you want to save the file on the PC hard drive, after quitting Internet Explorer, start Internet Explorer and select Yes and Always in the security warning screen. 52 English
54 Before displaying the result of proportional distribution, make exclusion period, special calculation day, and calculation period (period and month) settings. Excluded Time (Normal Type)... (See page 49) Special Calculation Days (Normal Type)... (See page 50) Calculation period Set period... (See page 51) Month... (See page 52) 1.Before displaying the result of proportional distribution, make exclusion period (normal type), special calculation day (normal type), and collection period (period and month) settings. Press the in the Main screen (Screen 1) for proportional distribution. Screen 2 for PPD Export Result is displayed. The periods when no collection data was obtained are displayed in the format of [YMD][H]:00. Screen 3: Collection result Screen 1: Main screen for proportional distribution Go to the chapter (4) 8-17 Display Method of Proportional Distribution Result-2 4.The collection result list (5) shows the result of proportional distribution. The contents of the display are explained below. Screen 2: Collection check 2. The message This processing may take time. Start processing? is displayed. To start processing, press. If you do not want to start processing, press. The Main screen (Screen 1) displays when you press. 3.If there were periods when no collection data was obtained, Screen 3 for the collection result is displayed. Press (4). Indoor unit check button The result of proportional distribution is displayed on an indoor unit basis. The collection result list shows the name and integral power consumption of each indoor unit along with the power consumption of the indoor unit not in operation. Zone check button Press this button to display the sum total of the results of proportional distribution of all the indoor units registered with the zone. The collection result list shows the name and integral power consumption of the zone along with the power consumption of the zone not in operation. Total check button Press this button to display the sum total of the results of proportional distribution of all the indoor units. The collection result list shows the integral power consumption of the total air conditioners and the power consumption of these air conditioners not in operation. Calculation period The period displayed shows the collection start year, month, and date and the collection end year, month, and date. Screen 4: Screen for collection result of air conditioners (5) (6) English 53
55 Screen 5: Screen for zone collection result (5) 9. PRECAUTIONS FOR WINDOWS VISTA 9-1 Precautions for Using Windows Vista In Windows Vista, User Account Control (UAC) now restricts the user permission regardless of user types (administrator/general user). Thus, when using Windows Vista, in order to click the button to save the aggregation results in a file, you need to turn OFF Protected Mode for Internet Explore shown in the status bar. You cannot save the aggregation results in a file even if you click the button when Protected Mode is turned ON. To turn OFF Protected Mode for Internet Explore, carry out one of the following three methods: Protected Mode : Off (6) Screen 6: Screen for total collection result (5) 5.Screen 4 or 5 or 6 is displayed as explained below, depending on the button selected. Air conditioner check button: Screen 4 for the collection result of air conditioners. Zone check button: Screen 5 for the zone collection result. Total check button: Screen 6 for the total collection result. 6.To save the collection result on the hard disk of the PC, press (6) button in Screens 4 to 6. Select and save the desired portion. The collection result is saved in CSV format. Three files, i.e., ZONE.CSV, HOURLY.CSV, and a file containing data on the collection period (collection start date_end date) with the delimiter and extension (.CSV), are saved. 7.If you want to display and save the result of proportional distribution of a different period, repeat steps 1 to 6. (6) Clicking the button allows you to save the aggregation results in a file. Protected Mode : On Protected Mode : Off You cannot save the aggregation results in a file even if you click the button. Protected Mode : On 54 English
56 1. Method 1 Run Internet Explorer as an administrator When you used the procedures as shown in the figure below to run Internet Explorer as an administrator, Protected Mode: Off is displayed in the status bar of Internet Explorer (see below), allowing you to click the Output to file button to save the aggregation results in a file. Right-click Internet Explorer Select Run as an administrator Check that Protected Mode is turned OFF (5) Click the button in Launch Internet Explorer Browser Properties window. (6) Start up Internet Explorer, check that Protected Mode is turned OFF (5) (4) 2.Method 2 Run Internet Explorer always as an administrator Before starting up Internet Explorer, carry out the procedures - (6) below and start up Internet Explorer, and Protected Mode: Off is displayed in the status bar of Internet Explorer, allowing you to click the Output to file button to save the aggregation results in a file. However, when carrying out this method, take into consideration that it can incur the security vulnerability. Right-click Internet Explorer Open the property of Internet Explorer Select Advanced in the property of Internet Explorer to open the Advanced Properties window (4) Check Run as administrator in the Advanced Properties window English 55
57 (6) (4) (6) 3.Method 3 Disable Protected Mode You can save the aggregation results in a file regardless of your user type (administrator/general user) by restricting the permission with User Account Control (UAC). However, when carrying out these procedures below, take into consideration that it can incur the security vulnerability. Select Tool Open Internet Option Uncheck Enable Protected Mode (4) Click the button in Internet Option window. (5) Click the button in Warning! window. (6) Start up Internet Explorer, check that Protected Mode is turned OFF (6) (5) (6) 56 English
58 10. BEFORE CONTACTING US: TROUBLESHOOTING Problems Air conditioners are not operational, although I did not click the stop button on the web interface. Air conditioners are operational, although I did not click the start button on the web interface. The temperature setting and/or operation mode of the air conditioner were changed, although I did not change these settings on the web interface. Possible Reasons and Solutions The most likely causes are: 1. The air conditioners were stopped using the local remote controllers. 2. The air conditioners were stopped from the intelligent Touch Controller console or any centralized controller. 3. A power failure occurred. 4. A schedule program set via the web interface stopped the air conditioners. 5. The Heating Optimization function of the intelligent Touch Controller stopped the air conditioners. In the HEAT operation mode room temperature may increase if thermostats do not work. The function prevents this problem by automatically stopping air conditioners. For more information, refer to the intelligent Touch Controller operation manual. The most likely causes are: 1. The air conditioners were started using local remote controllers. 2. The air conditioners were started from the intelligent Touch Controller console or any centralized controller. 3. A schedule program set via the web interface started the air conditioners. 4. The Temperature Limit function of the intelligent Touch Controller started the air conditioners. This function prevents room temperature from becoming extremely high or low by automatically starting air conditioners when a specified temperature threshold is exceeded. For more information, refer to the intelligent Touch Controller operation manual. The most likely causes are: 1. The settings were changed using the local remote controllers. 2. The settings were changed from the intelligent Touch Controller console or any centralized controller. 3. A schedule program set via the web interface changed the settings. 4. The Automatic Changeover function of the intelligent Touch Controller changed the settings. This function maintains optimal room temperature by automatically changing the operation mode and/or temperature setting according to the changing environment conditions. For more information, refer to the intelligent Touch Controller operation manual. English 57
59 Problems The following dialog box is displayed stating that a communication error occurred, and I cannot operate the air conditioners from my PC. Screen 1: Possible Reasons and Solutions The most likely causes are: 1. Your PC is not cabled correctly to the intelligent Touch Controller. 2.The intelligent Touch Controller is turned off. Clicking the OK button on the dialog box (Screen 1) displays the Screen 2. Close your browser software and then restart it. Screen 2: I cannot access the intelligent Touch Controller web interface. When accessing the intelligent Touch Controller web interface, the following screen is displayed. Your PC is not correctly connected to the network. The intelligent Touch Controller address entered in the browser is incorrect. The intelligent Touch Controller is turned off. The network is congested. Wait for a while and then access it again. This message informs you that Java plugin is not installed or the version of the installed Java plugin is not supported. Install the correct version of Java plugin. Refer to BEFORE STARTING for more information. (See page 3) When accessing the intelligent Touch Controller web interface, the following screen is displayed. This message informs you that your browser does not support the frame function. Check you browser s specifications. Refer to BEFORE STARTING for more information. (See page 3) 58 English
60 Problems I can access the web interface. However it takes too much time to refresh the screen. The room temperature value on the intelligent Touch Controller web interface does not match the actual measurement value. Java plugin does not work correctly. Possible Reasons and Solutions The network may be congested. Wait for a while and then access it again. Since the suction temperature of air conditioners is used, this may not reflect the actual measurement value, especially when the indoor unit s fans are stopped. This temperature value should be considered as a rough indicator. Java plugin is not installed correctly. The version of the installed Java plugin is not supported. The latest version may not be supported. Refer to BEFORE STARTING for more information. (See page 3) 11. AFTER-SALES SERVICE To have the product repaired, prepare the following information Model Date of installation Circumstances - as detailed as possible Address, name, phone number Relocation: Relocation should be performed by a professional contractor. Be sure to contact the vendor you purchased the product from or the nearest service station. The customer will be charged for the expense required for transfer work. Questions: For after-sales service, contact the vendor you purchased the product from or the nearest service station. English 59
61 EM04A057D (0905) FS
SYSTEM Inverter Air Conditioners
OPERATION MANUAL SYSTEM Inverter Air Conditioners MODEL Ceiling Suspended type FXHQ12MVJU FXHQ24MVJU FXHQ36MVJU Read these instructions carefully before installation. Keep this manual in a handy place
Power Proportional Distribution Software
EM04A056 OPERATION MANUAL Power Proportional Distribution Software MODEL DCS002C51 The above intelligent Touch Controller is available separately. Thanks for your having purchased our product, Power Proportional
Central Controller G-50A/GB-50A Web Browser Operation Manual (For System Maintenance Engineer)
Mitsubishi Electric Building Air-conditioner Control System Central Controller G-50A/GB-50A Web Browser Operation Manual (For System Maintenance Engineer) Contents 1 Introduction...1 1-1 Conventions Used
QUICK REFERENCE. Wired remote controller BRC2E52C7 BRC3E52C7
QUICK REFERENCE BRCEC BRCEC BRCEC BRCEC Table of contents Page Operation General safety precautions Features and functions Name and function of switches Name and function of icons Description of the operation
Features Reference. About Unified Communication System. Before Using This Machine. Starting a Meeting. What You Can Do During the Meeting
Features Reference About Unified Communication System Before Using This Machine Starting a Meeting What You Can Do During the Meeting Leaving a Meeting Managing Address Book Changing Network Configuration
4P359542-1H. Wireless LAN Connecting Adapter <BRP069A41> Installation Manual
4P359542-1H Wireless LAN Connecting Adapter Installation Manual Wireless LAN Connecting Adapter Installation Manual Homepage: http://www.onlinecontroller.daikineurope.com For details
OPERATION MANUAL. and System air conditioner RXYSQ4P8V1B RXYSQ5P8V1B RXYSQ6P8V1B RXYSQ4P8Y1B RXYSQ5P8Y1B RXYSQ6P8Y1B
OPERATION MANUAL and System air conditioner RXYSQP8VB RXYSQP8VB RXYSQ6P8VB RXYSQP8YB RXYSQP8YB RXYSQ6P8YB RXYSQPA7VB RXYSQPA7VB RXYSQ6PA7VB RXYSQPA7YB RXYSQPA7YB RXYSQ6PA7YB RXYQP9WB RXYQ8P9WB RXYQ0P9WB
EasyMP Monitor Operation Guide Ver.4.50
EasyMP Monitor Operation Guide Ver.4.50 Notations Used in This Guide The following table shows the symbols used in this manual, along with descriptions of what they mean. Attention s Indicates procedures
OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)
OPERATION MANUAL (Ceiling mounted duct type) VAM50FB VAM500FB VAM650FB VAM800FB VAM000FB VAM500FB VAM000FB 8 7 6 9 5 7 5 0 6 8 6 9 0 5 5 7 7 6 7 A A B B 5 6 5 6 7 VAM50F VAM800F VAM500F VAM500F VAM000F
OPTIONAL SLENDER REMOTE CONTROL
DAIKIN ROOM AIR CONDITIONER Operation Manual OPTIONAL SLENDER REMOTE CONTROL BRC944A2B READ BEFORE OPERATION Safety Precautions...2 Names of Functions of Parts...4 Preparation before Operation...5 OPERATION
17 April 2014. Remote Scan
17 April 2014 Remote Scan 2014 Electronics For Imaging. The information in this publication is covered under Legal Notices for this product. Contents 3 Contents...5 Accessing...5 Mailboxes...5 Connecting
EasyMP Monitor Operation Guide Ver.4.53
EasyMP Monitor Operation Guide Ver.4.53 2 Notations Used in This Guide The following table shows the symbols used in this manual, along with descriptions of what they mean. q s Indicates additional information
EasyMP Monitor Operation Guide Ver.4.40
EasyMP Monitor Operation Guide Ver.4.40 2 Notations Used in This Guide The following table shows the symbols used in this manual, along with descriptions of what they mean. Caution q s Indicates procedures
USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB98-29565A(1) ENGLISH ESPAÑOL
USER S MANUAL Duct Type Series MH MH FEEA Series FUEA Series ENGLISH ESPAÑOL PORTUGUÊS E HNIKA DEUTSCH ITALIANO FRANÇAIS Free Joint Multi Air Conditioner (Cooling and Heating) E S F I P D G DB98-29565A(1)
MULTIFUNCTIONAL DIGITAL SYSTEMS. Operator's Manual for TWAIN Driver/File Downloader
MULTIFUNCTIONAL DIGITAL SYSTEMS Operator's Manual for TWAIN Driver/File Downloader 2008 KYOCERA MITA Corporation All rights reserved Preface Thank you for purchasing KYOCERA MITA Multifunctional Digital
Split Type Room Air Conditioner. KSWM units
OWNER S MANUAL Split Type Room Air Conditioner KSWM units Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.
F453. TiF453. User guide 10/11-01 PC
F453 TiF453 User guide 10/11-01 PC 2 TiF453 User guide Contents 1. Hardware and Software requirements 4 2. Installation 4 1.1 Minimum Hardware requirements 4 1.2 Minimum Software requirements 4 3. Fundamental
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA
USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your
Contents. Preparation/SetUp...2
LAN Control Utility User Manual (for MH850U) Contents Preparation/SetUp... Preparation before using the network function... Connection...3 Installation...3 Setting the IP address of the projector...5 When
Installation & Upgrade Guide. Hand-Held Configuration Devices Mobility DHH820-DMS. Mobility DHH820-DMS Device Management System Software
Installation & Upgrade Guide Hand-Held Configuration Devices Mobility DHH820-DMS Mobility DHH820-DMS Device Management System Software WARNING notices as used in this manual apply to hazards or unsafe
RCS-TM80BG. Contents 4. Weekly Program Function... EG-6 5. Outing Function... EG-12 6. Sleeping Function... EG-14 XXX XXXX XXXX XXXX XXXX
Save These Instructions! Save These Instructions! Save These Instructions! Save These Instructions! Save These Instructions! Save These Instructions! Save These Instructions! 1. Important Safety Instructions...
Dell SonicWALL Aventail 10.6.5 Connect Tunnel User Guide
Dell SonicWALL Aventail 10.6.5 Connect Tunnel User Guide 1 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your system. CAUTION: A CAUTION indicates
Configuring Devices for Use with Cisco Configuration Professional (CCP) 2.5
Configuring Devices for Use with Cisco Configuration Professional (CCP) 2.5 Objectives Part 1: Configure CCP Access for Routers Enable HTTP/HTTPS server. Create a user account with privilege level 15.
Operating Instructions Air Conditioner
F566272 Operating Instructions Air Conditioner CS-C18FFH CS-C28FFH CU-C18FFH CU-C28FFH ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
MULTIFUNCTIONAL DIGITAL SYSTEMS. Operator s Manual for Backup/Restore Utility
MULTIFUNCTIONAL DIGITAL SYSTEMS Operator s Manual for Backup/Restore Utility 2009 KYOCERA MITA Corporation All rights reserved Preface Thank you for purchasing Multifunctional Digital Color Systems. Read
WALL MOUNTED SPLIT TYPE AIR CONDITIONER
WALL MOUNTED SPLIT TYPE AIR CONDITIONER MANUAL 8 OM-G12-ACSON CONTENTS - Operating Guide page 1 - G12 Remote Controller Indication page 2 - Indicator Lights page 4 - Installation of Aroma page 5 - Auto
HP MediaSmart Server Software Upgrade from v.1 to v.3
HP MediaSmart Server Software Upgrade from v.1 to v.3 Table of Contents Upgrade Your Server Software to HP MediaSmart Server v.3 2 Before You Begin 3 What's New... 3 Features That Will Change... 4 Prepare
Core Protection for Virtual Machines 1
Core Protection for Virtual Machines 1 Comprehensive Threat Protection for Virtual Environments. Installation Guide e Endpoint Security Trend Micro Incorporated reserves the right to make changes to this
DAIKIN ROOM AIR CONDITIONER MODELS. Operation Manual ENGLISH ESPAÑOL TURKISH
DAIKIN ROOM AIR CONDITIONER Operation Manual MODELS FT50GAVEA FT60GAVEA FTY50GAVA FTY60GAVA ENGLISH ESPAÑOL TURKISH CONTENTS READ BEFORE OPERATION Safety Precautions... Names of Parts Indoor unit, Opening
SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL
SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL Thank you for choosing our Air Conditioner. Please read this OWNER'S MANUAL carefully prior to use and keep it for further reference. CONTENTS Contents
Use and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
EasyMP Multi PC Projection Operation Guide
EasyMP Multi PC Projection Operation Guide Contents Introduction to EasyMP Multi PC Projection... 7 EasyMP Multi PC Projection Features... 7 Connection to Various Devices... 7 Four-Panel Display... 8
SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2
SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with
User s Guide for version 5 Page
Network Management Interface Catalog VPi 32.15E For use with these ATS products: 7000 & 4000 Series (Group 5 Controller) Series 300 (Group 1 Controller), and 940, 962, 436, 434, 447, 448 (Group 6A/7A Control
Charter Business Desktop Security Administrator's Guide
Charter Business Desktop Security Administrator's Guide Table of Contents Chapter 1: Introduction... 4 Chapter 2: Getting Started... 5 Creating a new user... 6 Recovering and changing your password...
Operating Instructions Air Conditioner
P07-T10130 Operating Instructions Air Conditioner Indoor Unit CS-F24DD1E5 CS-F28DD1E5 CS-F34DD1E5 CS-F43DD1E5 CS-F50DD1E5 Outdoor Unit Inverter Model (HBE5 Series) CU-YL24HBE5 CU-YL28HBE5 CU-YL34HBE5 CU-YL43HBE5
AW-HE60 Firmware Upgrade Procedure
AW-HE60 Firmware Upgrade Procedure Please be sure to read this first. AW-HE60 Upgrade Procedure February 2015 The update of AW-HE60 camera is performed via a network from Web setting screen on
MULTIFUNCTIONAL DIGITAL SYSTEMS. Operator s Manual for Backup/Restore Utility
MULTIFUNCTIONAL DIGITAL SYSTEMS Operator s Manual for Backup/Restore Utility 2008 TOSHIBA TEC CORPORATION All rights reserved Under the copyright laws, this manual cannot be reproduced in any form without
COPY. Projector Monitoring Software. User s Manual. Ver. 1.0.0
Projector Monitoring Software Ver. 1.0.0 User s Manual Introduction "Projector Monitoring Software" (hereafter referred to as "this software") is a software that uniformly manages network-connected compliant
Owner s Manual RBC-AMS41E. Remote controller with weekly timer. Owner s Manual
Owner s Manual Remote controller with weekly timer RBC-AMS41E Owner s Manual Remote controller Mode d emploi Télécommande Bedienungsanleitung Fernbedienung Manuale di istruzioni Telecomando Manual del
OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher
OPERATION MANUAL MV-410RGB Layout Editor Version 2.1- higher Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410RGB Layout
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
RAV-SM564UT-E RAV-SM804UT-E RAV-SM1104UT-E RAV-SM1404UT-E RAV-SM1604UT-E
AIR CONDITIONER (SPLIT TYPE) Owner s Manual Indoor Unit Model name: For commercial use 4-way Cassette Type RAV-SM564UT-E RAV-SM804UT-E RAV-SM1104UT-E RAV-SM1404UT-E RAV-SM1604UT-E Owner s Manual English
HP MediaSmart Server Software Upgrade from v.2 to v.3
HP MediaSmart Server Software Upgrade from v.2 to v.3 Table of Contents Table of Contents Upgrade Your Server Software to HP MediaSmart Server v.3 2 Before You Begin 3 What's New 3 Features That Will
Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities.
Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities. More Freedom to Administrators Connectable up to 128 Indoor Unit Groups (256 indoor
Allworx OfficeSafe Operations Guide Release 6.0
Allworx OfficeSafe Operations Guide Release 6.0 No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopy,
TABLE OF CONTENTS QUICK START... 1 DIAGRAM OF THE DIGITAL PHOTO FRAME... 2 KEYPAD BUTTON FUNCTIONS... 3 REMOTE CONTROL FUNCTIONS..
TABLE OF CONTENTS QUICK START........ 1 DIAGRAM OF THE DIGITAL PHOTO FRAME... 2 KEYPAD BUTTON FUNCTIONS..... 3 REMOTE CONTROL FUNCTIONS..4 DIGITAL PHOTO FRAME NAVIGATION........5 OSD MENU FUNCTIONS..6
Network Camera. Quick Operation Guide V4.0.1
Network Camera Quick Operation Guide V4.0.1 Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to DS-2CD8253F-EI(Z),
IsItUp Quick Start Manual
IsItUp - When you need to know the status of your network Taro Software Inc. Website: www.tarosoft.com Telephone: 703-405-4697 Postal address: 8829 110th Lane, Seminole Fl, 33772 Electronic mail: [email protected]
SHARP Digital Signage Software Pro PN-SS05 OPERATION MANUAL
SHARP Digital Signage Software Pro PN-SS05 Version 4.1 OPERATION MANUAL Contents Introduction... 2 Precautions on Use...2 Trademarks...2 How to Read this Manual...3 Definitions...3 Installing/Launching...
How To Use An Easymp Network Projector On A Computer Or Network Projection On A Network Or Network On A Pc Or Mac Or Ipnet On A Laptop Or Ipro Or Ipo On A Powerbook On A Microsoft Computer On A Mini
EasyMP Network Projection Operation Guide Contents 2 Before Use Functions of EasyMP Network Projection....................... 5 Sharing the Projector....................................................
How To Use Senior Systems Cloud Services
Senior Systems Cloud Services In this guide... Senior Systems Cloud Services 1 Cloud Services User Guide 2 Working In Your Cloud Environment 3 Cloud Profile Management Tool 6 How To Save Files 8 How To
Projector Monitoring Software
Projector Monitoring Software Ver. 1.0.0 User s Manual Introduction "Projector Monitoring Software" (hereafter referred to as "this software") is a software that uniformly manages network-connected compliant
Instruction Manual. Window Wiper AFW900. (Read carefully before use)
Instruction Manual Window Wiper AFW900 (Read carefully before use) When using electrical appliances, basic precautions should always be followed, including the fact READ ALL INSTRUCTIONS IN THIS MANUAL
Amcrest 960H DVR Quick Start Guide
Amcrest 960H DVR Quick Start Guide Welcome Thank you for purchasing our Amcrest 960H DVR! This quick start guide will help you become familiar with our DVR in a very short time. Before installation and
Room Air Conditioners
User Manual Room Air Conditioners R410A Split Type Y Series DC INVERTER ECO940SD ECO120SD ECO1840SD Please read this installation manual completely before installing the product. When the power cord is
Digital Photo Picture Frame. Operation Manual
Digital Photo Picture Frame Operation Manual 20070309 CONGRATULATIONS on your purchase of a Polaroid 7 LCD Digital Photo Picture Frame. Please read carefully and follow all warnings and instructions in
HP ProLiant ML150 System Monitor User Guide
HP ProLiant ML150 System Monitor User Guide November 2003 Contents Introduction... 1 MSM Features...1 Installing MSM... 3 Installing MSM Server on the Server...3 Installing MSM Console on a Client PC...3
Topaz Installation Sheet
Topaz Installation Sheet P/N 460924001E ISS 08FEB12 Content Introduction... 3 Recommended minimum requirements... 3 Setup for Internet Explorer:... 4 Topaz installation... 10 Technical support... 14 Copyright
AXIS Camera Station Quick Installation Guide
AXIS Camera Station Quick Installation Guide Copyright Axis Communications AB April 2005 Rev. 3.5 Part Number 23997 1 Table of Contents Regulatory Information.................................. 3 AXIS Camera
Chapter 1 Downloading Images to Your Computer (Windows)
Software User Guide For the safe use of your camera, be sure to read the Safety Precautions thoroughly before use. Types of software installed on your computer varies depending on the method of installation
Xerox 700 Digital Color Press with Integrated Fiery Color Server. Utilities
Xerox 700 Digital Color Press with Integrated Fiery Color Server Utilities 2008 Electronics for Imaging, Inc. The information in this publication is covered under Legal Notices for this product. 45072726
THE NEW GENERATION IN TECHNOLOGY. NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking. Operating Instructions
THE NEW GENERATION IN TECHNOLOGY NI-3103A Alarm Clock w/fm Radio ipod & iphone Docking Operating Instructions Table of Contents Important Safeguards... 3 Parts... 6 Controls... 6 To Set Up... 7 ipod/iphone
MLM1000 Multi-Layer Monitoring Software 061-4281-00
MLM1000 Multi-Layer Monitoring Software 061-4281-00 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - FAX 781.665.0780 - TestEquipmentDepot.com Read This First contains release
LG Wireless Remote Controller
Visit us at : http://www.lgservice.com LG Wireless Remote Controller Owner's & Installation Manual Models: PQWRHSF0 PQWRCSF0 LG ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH IMPORTANT Please read this installation
Network Client. Troubleshooting Guide FREQUENTLY ASKED QUESTIONS
Network Client Troubleshooting Guide 1 Network Client Troubleshooting Guide The first section of this guide answers some frequently asked questions (FAQs) about the operation of Intellex and the Network
Installation Guide - Client. Rev 1.5.0
Installation Guide - Client Rev 1.5.0 15 th September 2006 Introduction IntraNomic requires components to be installed on each PC that will use IntraNomic. These IntraNomic Client Controls provide advanced
Java. How to install the Java Runtime Environment (JRE)
Java How to install the Java Runtime Environment (JRE) Install Microsoft Virtual Machine (VM) via System Check Install Sun Java Runtime Environment (JRE) via System Check Loading Java Applet Failed How
DUCT TYPE AIR CONDITIONER
OPERATING MANUAL OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES AIR CONDITIONER DUCT TYPE English Deutsch
Before using your air conditioner, please read this manual carefully and keep it for future reference. ROOM AIR CONDITIONER
Before using your air conditioner, please read this manual carefully and keep it for future reference. SPLIT- TYPE ROOM AIR CONDITIONER Read This Manual Inside you will find many helpful hints on how to
Power Monitoring Expert 7.2
Power Monitoring Expert 7.2 PDF version of the Web Applications online help 7ENxx-00xx-00 07/2013 PDF version of the Web Applications online help Safety information Safety information Important information
Manuals for This Product
Installation Guide Manuals for This Product Manuals for this product have the following structure. Read the manual according to your purpose for using this product. Disc Guides with this symbol are PDF
Wine Cooler with Thermo-Electric Cooling & Heating Technology
Wine Cooler with Thermo-Electric Cooling & Heating Technology Model number: WC-0888H (8-bottles capacity) Instruction Manual Please read carefully and follow all safety rules and operating instructions.
DATA PROJECTOR XJ-A146/XJ-A246/XJ-A256
DATA PROJECTOR XJ-A146/XJ-A246/XJ-A256 E Data Projector Wireless Function Guide Be sure to read the precautions in the Setup Guide that comes with the Data Projector. Be sure to keep all user documentation
User Manual Color video door phone
User Manual Color video door phone CDV-70KM Thank you for purchasing COMMAX products. Please carefully read this User s Guide (in particular, precautions for safety) before using a product and follow instructions
DATA PROJECTOR XJ-A135/XJ-A145/XJ-A235/ XJ-A245
DATA PROJECTOR XJ-A135/XJ-A145/XJ-A235/ XJ-A245 E Data Projector Wireless Function Guide Be sure to read the precautions in the User s Guide (Basic Operations) that comes with the Data Projector. Be sure
DAIKIN ROOM AIR CONDITIONER FT50BSG FT60BSG MODELS. Operation Manual
DAIKIN ROOM AIR CONDITIONER Operation Manual MODELS FT50BSG FT60BSG CONTENTS READ BEFORE OPERATION Safety Precautions... 2 Names of Parts Indoor unit, Opening the front grille... 5 Remote controller, Outdoor
MySabre with Sabre VPN
MySabre with Sabre VPN MIGRATION / INSTALLATION GUIDE T a b l e o f C o n t e n t s Table of Contents... ii Introduction... 3 Before Installing... 3 New MySabre User Installation... 4 Appendix A ActiveX
How To Use A Sata Dsa Hard Disk Storage System
EXTERNAL RAID STORAGE OF HDDS INSTRUCTION MANUAL CAUTION RISK OF ELECTRIC SHOCK CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT OPEN COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED
Action Camcorder Rollei Youngstar USER MANUAL
Action Camcorder Rollei Youngstar USER MANUAL Mounting Accessories 1 Functions This user's manual has referred to the latest information we had when this user s manual was made. The screen display and
Central Management System
Central Management System Software Installation Guide Ver. 1.5.0.101115.001 ... ii System Introduction... 3 Client/Server Architecture...3 System Requirements... 4 System Setup...4 Multiple Monitor Configuration...5
MULTIFUNCTIONAL DIGITAL COLOR SYSTEMS / MULTIFUNCTIONAL DIGITAL SYSTEMS. Remote Scan driver Help
MULTIFUNCTIONAL DIGITAL COLOR SYSTEMS / MULTIFUNCTIONAL DIGITAL SYSTEMS Remote Scan driver Help 2012, 2013 TOSHIBA TEC CORPORATION All rights reserved Under the copyright laws, this manual cannot be reproduced
To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)
OPERATION MANUAL Split System Ducted Air Conditioner To suit Daikin FDY "F" Series and FD "F" Series AIR CONDITIONER A hr o C (and other models incorporating BRC1B62/52 Remote Controller) Dear Owner, Thank
MULTIFUNCTIONAL DIGITAL COLOR SYSTEMS / MULTIFUNCTIONAL DIGITAL SYSTEMS. e-filing Guide
MULTIFUNCTIONAL DIGITAL COLOR SYSTEMS / MULTIFUNCTIONAL DIGITAL SYSTEMS e-filing Guide 2012-2014 TOSHIBA TEC CORPORATION All rights reserved Under the copyright laws, this manual cannot be reproduced in
File Management Utility User Guide
File Management Utility User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held
Microsoft product screenshots are reprinted with permission from Microsoft Corporation.
P3PC-4162-03EN Getting Started Thank you for purchasing ScanSnap ix500 (hereinafter referred to as "the ScanSnap"). This manual describes the preparation required for use of the ScanSnap. Follow the preparation
MULTIFUNCTIONAL DIGITAL SYSTEMS. Operator's Manual for Remote Scan Driver
MULTIFUNCTIONAL DIGITAL SYSTEMS Operator's Manual for Remote Scan Driver 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved Under the copyright laws, this manual cannot be reproduced in any form without
AIR-CONDITIONER SPLIT TYPE
FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,
Tablet PC Tutorial for Windows 7
VIRGINIA TECH Tablet PC Tutorial for Windows 7 Getting Started Guide Instructional Technology Team, College of Engineering Last Updated: Fall 2013 Email [email protected] if you need additional assistance
VIVA 4G LTE Mini Router. Quick Start Guide
VIVA 4G LTE Mini Router Quick Start Guide Thank you for choosing the VIVA 4G LTE Mini Router (hereinafter referred to as the E57) The supported functions and actual appearance are subject to the product
Fiery E100 Color Server. Welcome
Fiery E100 Color Server Welcome 2011 Electronics For Imaging, Inc. The information in this publication is covered under Legal Notices for this product. 45098226 27 June 2011 WELCOME 3 WELCOME This Welcome
Personal Call Manager User Guide. BCM Business Communications Manager
Personal Call Manager User Guide BCM Business Communications Manager Document Status: Standard Document Version: 04.01 Document Number: NN40010-104 Date: August 2008 Copyright Nortel Networks 2005 2008
OPERATING INSTRUCTIONS INDOOR UNIT MSZ-A18YV MSZ-A24YV MSZ-A26YV MSZ-A30YV
SPLIT-TYPE AIR CONDITIONERS OPERATING INSTRUCTIONS INDOOR UNIT MSZ-A18YV MSZ-A24YV MSZ-A26YV MSZ-A30YV For customers Thank you very much for purchasing this Mitsubishi room air conditioner. To use this
Web VTS Installation Guide. Copyright 2006-2010 SiiTech Inc. All rights reserved.
Web VTS Installation Guide Copyright 2006-2010 SiiTech Inc. All rights reserved. Table of Contents Overview of Web VTS... 1 System Requirements... 2 Installation Sequence... 3 Installing Web VTS... 6 ii
Operating Instructions Split System Air Conditioner
Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This
Features of your Air to water heat pump
Features of your Air to water heat pump Running Costs-Reduction of Up to 33.3% Samsung EHS, known for its world class efficiency (12kW floor heating system with COP of 4.60), can reduce 33.3% of your running
TPM. (Trusted Platform Module) Installation Guide V2.1
TPM (Trusted Platform Module) Installation Guide V2.1 Table of contents 1 Introduction 1.1 Convention... 4 1.2 TPM - An Overview... 5 2 Using TPM for the first time 2.1 Enabling TPM... 6 2.2 Installing
OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump
R-410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H)-System, DFC4(A/H)3-Outdoor, DFF4(A/H)H-Indoor Please read the operating instructions and safety precautions carefully
TANDBERG MANAGEMENT SUITE 10.0
TANDBERG MANAGEMENT SUITE 10.0 Installation Manual Getting Started D12786 Rev.16 This document is not to be reproduced in whole or in part without permission in writing from: Contents INTRODUCTION 3 REQUIREMENTS
