ClearPass 6.x. Tech Note: ClearPass. Clustering Design Guidelines. Version Date Modified By Comments David Wilson Early Draft Version
|
|
|
- Rosalyn Page
- 9 years ago
- Views:
Transcription
1 ClearPass 6.x Tech Note: ClearPass Clustering Design Guidelines Version Date Modified By Comments David Wilson Early Draft Version 0.2 August 2014 Danny Jump Published Draft (#10119) 1.0 November Danny Jump Published Version 1
2 Table of Contents Table of Contents... 2 Table of Figures... 4 Copyright... 6 Open Source Code... 6 Introduction... 7 Audience... 7 Notes on the Version of this Document... 7 V1 October Clustering Overview... 8 WAN Considerations L2/L Campus Considerations L2/L ClearPass Databases... 8 Publisher/Subscriber Model... 9 What Is Replicated? What Is A Large- Scale Deployment? Clustering Example Clustering Example Network Traffic Flows Cluster- wide replication Handling Authentication Requests Optimizing Authentication processing for a MSFT AD domain Internal API For Dynamic Content Creation (Guest/Onboard) Onboard Certificates And OCSP
3 Load Balancing Auto Backup Collector aka Data Puller Linux Installation Windows Installation Publisher Down Guest/Onboard The Standby- Publisher Publisher Failover - L2 or L3? How the Failover Process works What do you lose when the Publisher fails? Subscriber Down Design Guidelines Allow HTTP/S Between Publisher and Subscribers Allow Database & other Traffic Between PUB and SUB s Size The Publisher Node Appropriately Provide Sufficient Bandwidth Between Publisher/Subscribers Bandwidth Usage/Sizing for a CPPM Cluster Volumetrics of Cluster in an idle state Volumetrics of Cluster in an loaded state Use Zones For Geographical Regions Use Nearest Subscriber Node Use Subscriber Nodes As Workers Use Dedicated Insight Node Insight Setup Insight Resilience
4 Cluster Wide Parameters config settings High Capacity Guest Enabling HCG Supported number of Users in HCG HCG Cluster HCG - Other related information (licensing/disabled features) Cluster Operations Making a node a Subscriber from the GUI Timings to add a CPPM Node to a cluster Timings Making a node a Subscriber from the CLI Cluster Administration Cluster Upgrades Cluster Upgrade Tool Scaling Limitations Virtual IP Considerations Table of Figures Figure 1 - Subscriber GUI 'read- only' banner message warning... 9 Figure 2 - Node specific configuration sections Figure 3 - Cluster Example 1 - Picture Figure 4 - Clustering Example 2 - picture Figure 5 - Subscriber 'Read Only Access' when changing a guest password Figure 6 - OCSP Recommendations Summary Figure 8 - Autobackup Options Figure 9 - List of auto- backup files Figure 10 - Setting up the Standby Publisher Figure 11 - Configuring Standby over a L3 connection - WARNING Figure 12 Total Data in bytes between Publisher and Subscriber in 24- hour idle period Figure 13 - Publisher traffic to Subscriber over 24- hours Figure 14 Total Data in Bytes between Subscriber and Publisher in 24- hour idle period Figure 15 - Subscriber traffic to Publisher over 24- hours Figure 16 - Enabling Insight on a CPPM node Figure 17 - Insight resiliency across cluster nodes
5 Figure 18 - Enabling Insight on multiple nodes and defining the Backup source order Figure 19 - Enabling HCG mode Figure 20 Warning message when enabling HCG mode Figure 21 - Make Subscriber on GUI Figure 22 - Sync in Progress for new cluster node Figure 23 - Event Viewer success message after new cluster node added Figure 24 - Setting up cluster from CLI Figure 25 - Checking on cluster progress from CLI Figure 26 - Dropping Subscriber from Publisher Figure 27 - Drop Subscriber confirmation message Figure 28 - Drop Subscriber confirmation options Figure 29 - Resetting a CPPM node configuration Figure 30 - CLI messages for adding a node Figure 31 - Confirmation that an upgrade is completed
6 Copyright 2014 Aruba Networks, Inc. Aruba Networks trademarks include Aruba Networks, Aruba The Mobile Edge Company (stylized), Aruba Mobility- Defined Networks, Aruba Mobility Management System, People Move Networks Must Follow, Mobile Edge Architecture, RFProtect, Green Island, ETips, ClientMatchTM, Virtual Intranet AccessTM, ClearPass Access Management SystemsTM, Aruba InstantTM, ArubaOSTM, xsectm, ServiceEdgeTM, Aruba ClearPass Access Management SystemTM, AirmeshTM, AirWaveTM, Aruba CentralTM, and All rights reserved. All other trademarks are the property of their respective owners. Open Source Code Certain Aruba products include Open Source software code developed by third parties, including software code subject to the GNU General Public License (GPL), GNU Lesser General Public License (LGPL), or other Open Source Licenses. The Open Source code used can be found at this site: 6
7 Introduction This TechNote describes the design guidelines that are applicable to large- scale deployments of the ClearPass product. The intent is to provide documentation about what can and cannot be done with the publisher/subscriber clustering model implemented in ClearPass. These constraints will enable proposed designs to be checked for feasibility and compliance with recommended practices. Where it is practical, best practices will be documented, although not every conceivable use case or deployment can be covered here. Note: Where you see a red- chili this is to signify a hot important point and highlights that this point is to be taken as a best- practice recommendation. Audience The reader is assumed to be familiar with the ClearPass family of products, including Policy Manager, Insight, Guest and Onboard. Basic knowledge of IP networks and wide- area networking is also assumed. Notes on the Version of this Document V1 October 2014 This document has been released early to be shared with the field. Within this document is a host of valuable information covering the design/deployment/management of a clustered CPPM network and the important components such as Insight that need special consideration. At this juncture will realise that a small amount of pertinent information is missing. We are already actively gathering this and plan to release a V2 of this document before the end of calendar Please check back regularly for updates. 7
8 Clustering Overview Within this section we discuss the process of the initial design of a cluster. CPPM can be deployed either as a dedicated hardware appliance or a Virtual Machine running on top of VMware ESXi. We support a 500, 5,000 or a 25,000 endpoint appliance, the exception to this is when you deploy ClearPass in High Guest Capacity mode where the node can support 1,000, 10,000 and 50,000 Guests/day respectively. When demand exceeds the capacity of a single instance or we have a requirement to have a High Availability deployment we have the option of logically join multiple instances together to process the workload from the network. You can logically join physical and virtual instances and also join dissimilar sized CPPM instances, however careful planning must be taken especially if you plan to utilize the failover capabilities within the clustering feature. WAN Considerations L2/L3 Where a CPPM cluster is deployed and typical WAN technologies separate the nodes e.g. MPLS with low- speed (sub 10Mbps) and high- latency (>50ms RTT) then additional consideration regarding the deployment must be considered and discussed with the customer as outlined and discussed later in this document in Provide Sufficient Bandwidth Between Publisher/Subscribers. Campus Considerations L2/L3 No specific consideration is typically required when clustering in a Campus/LAN environment, though the placement of CPPM nodes SHOULD typically be close to the user population but not that critical. If the Campus network connecting building and faculty is based around a MAN/VPLS then there are no special considerations around bandwidth/latency and the main consideration here is then only the CPPM configuration and clustering for High Availability. ClearPass Databases A single ClearPass server makes use of several different databases: The configuration database contains most of the editable entries that can be seen in the GUI. This includes, but is not limited to: Administrative user accounts Local user accounts Service definitions Role definitions Enforcement policies and profiles Network access devices 8
9 Guest accounts Onboard certificates Most of the configuration shown within Guest and Onboard The log database contains activity logs generated by typical usage of the system. This includes information shown in Access Tracker and the Event Viewer. The Insight database records historical information generated by the Netevents framework, and is used to generate reports. Publisher/Subscriber Model ClearPass uses a publisher/subscriber model to provide a multiple- box clustering capability. Another term for this model is hub and spoke, where the hub corresponds to the publisher, and the spokes correspond to the subscribers. There is at most one active publisher in this model, and a potentially unlimited number of subscribers (we have tested as high as 40 nodes within a cluster). The publisher node has full read/write access to the configuration database. All configuration changes MUST be made on the publisher. The publisher sends configuration changes to each subscriber. The subscriber maintain a local copy of the configuration database and each have read- only access to a local copy of the configuration database. A background replication process handles the task of updating the configuration database based on the configuration changes received from the publisher. Because the subscriber has read- only access, a message will be displayed to an administrator logging in to that server, indicating that read- only access is available and that they should log into the publisher for full access. Figure 1 - Subscriber GUI 'read- only' banner message warning 9
10 What Is Replicated? Multiple items exist within a CPPM node/cluster that must be shared to ensure successful operation of the cluster. Only the configuration database is replicated. Note that the Log and Insight databases are not replicated across the cluster. However, certain items are node specific and these must be configured separately for each node, this can be achieved directly on the Publisher or individually on the node. The node specific attribute can be summarized as the configuration under the below highlighted sections. Figure 2 - Node specific configuration sections Note: Finally three other items that are node specific, Log Configuration, Local Shared Folders and Server Certificates (RADIUS and HTTPS) need to be individually configured. What Is A Large- Scale Deployment? Large- scale deployments are defined as those that would require the publisher node to be dedicated to servicing the subscriber nodes, i.e. the Publisher is not directly processing authentication requests. This is the case when the volume of configuration changes generated by all subscribers in the cluster impacts the publisher node. This limits the publisher node s capacity to handle other tasks and implies that it must become a dedicated node. Design Guidance: The dedicated Publisher should be a CP- HW- 25K appliance or a CP- VM- 25K that matches the minimum spec for the VM. The VM specification can be found here. Configuration changes that SHOULD be considered in the context of a large- scale deployment include: Creating, modifying or deleting a guest account Issuing or revoking an Onboard certificate Modifying Policy Manager configuration (adding a network access device, defining a new service, updating an enforcement profile, etc.) Adding new endpoints (including automatically created endpoints) in Policy Manager Modifications made to guest account or endpoint records with a Policy Manager post- authentication profile 10
11 Note that not every clustering scenario is a large- scale deployment. CPPM clustering may also be performed for other reasons, for example to distribute several CPPM nodes geographically for policy reasons, or to have an off- site disaster recovery system. Clustering Example 1 Authenticating corporate users with Guest access. A cluster of CP- HW- 5K s has two nodes (US East Coast and US West Coast). US- West is the publisher, and US- East is the subscriber. Each node handles the authentication traffic for 2,000 corporate endpoints. Each node also registers 100 guests per day. There are few configuration updates in the network. This fictitious customer example would not be considered a large- scale deployment: The additional load on the publisher due to clustering can be estimated at 100 guest accounts created per day. The authentication traffic on the subscriber node does not impose any additional load on the publisher and the new endpoints registered (in the order of 100 per day, assuming new guests each day) does also not add any significant load. This workload on the publisher is small and represents a fraction of its capacity. In this example, each node could be used as the backup for the other node. In the event of a node failure, the other node could handle the authentication requirements of all 4,000 endpoints plus 200 guest registrations per day. Figure 3 - Cluster Example 1 - Picture 11
12 Clustering Example 2 Authenticating conference center users. A cluster has three CP- HW- 25K s nodes in the same time- zone. Located in San Jose (Publisher), San Diego (Subscriber) and Seattle (Subscriber). Each node can registers up to 15,000 guests per day, often in short bursts. There is constant authentication traffic through the day from the onsite employees and guest. On some days, a node may be idle, but there are days where all nodes are busy. This would be considered a large- scale deployment: In our example the maximum potential load on the publisher due to the Guest account creation process can be estimated at 45,000 guest accounts being created per hour (peak rate), that equates to 12.5 account creations per sec, a max of 15 accounts per sec. This is a significant load on the publisher. In this example, a separate dedicated publisher node would be recommended: a hardware appliance Publisher, CP- HW- 25K, could theoretically handle up to 54,000 guest accounts being created per hour (15 per sec), but with bursts of Guest traffic being unpredictable during the hot hour and with the corresponding replication of these accounts to each of the subscriber nodes we consider this to be an example of a deployment warranting a dedicated Publisher. Figure 4 - Clustering Example 2 - picture So even though in theory the Publisher could process and create these Guest accounts, this amount of work in the hot- hour is not really feasible in addition to any other background network authentication/replication etc. the Publisher is excepted to perform. 12
13 Network Traffic Flows The table below lists the network ports that must be opened between the Pub and the Sub s Protocol Port Notes UDP 123 NTP time synchronization TCP 80 HTTP internal proxy TCP 443 HTTPS internal proxy and node- to- node communications TCP 4231 NetWatch (Post Authentication module) TCP 5432 Postgresql database replication All protocol/port combinations listed above should be bidirectional and should be open between any two nodes in the cluster. The reason for this is that any subscriber node can be promoted to the publisher node, which implies a fully connected network is necessary. To see the complete list of ports required across a CPPM cluster to ensure all processes beyond just the clustering process work correctly please review the document here. Cluster- wide replication Beyond the data that is replicated by the Multi- Master Cache (which is actually zone specific), data in the configuration database is replicated cluster wide. Data that is NOT replicated includes We discuss ZONES later in this document. Access Tracker Logs Session Log Accounting Data Event Viewer Data System Monitor Handling Authentication Requests The typical use case for Policy Manager is to process authentication requests using the policy framework. The policy framework is a selection of services that work to process but is not limited to and determine:- authentication, authorization, posture, enforcement, role etc. of the endpoint/end- user. In this use case, authentication typically involves a read- only operation as far as the configuration database is concerned: a cluster node receives an authentication request, determines the appropriate policies to apply, and responds appropriately. This does not require a configuration change, and can therefore be scaled across the entire cluster. 13
14 Note: Authentication is performed from the node itself to the configured identity store, whether local (as sync ed by the Publisher i.e. a Guest account) or external like MSFT AD. Logs relevant to each authentication request are recorded separately on each node, using that node s log database. Centralized reporting is handled by generating a Netevent from the node, which is sent to all Insight nodes and recorded in the Insight database. Optimizing Authentication processing for a MSFT AD domain When attaching a CPPM node to an Active- Directory (AD) domain, (note that each CPPM node must be separately attached/enrolled) this is the node that we send the Auth request to. In CPPM 6.3 we added add some logic to control the processing of where CPPM sends the authentication request to when the primary- node you initially connect to fails. This is achieved via the configuration of AD Password Servers. If NO Password Servers are configured then the processing of where the Auth requests are sent is indeterminate after the primary node fails. To better understand the processing of which server in the network could be used to process these request look at the below nslookup example. This shows you the servers in the network that can process the CPPM AD authentication requests. Knowing this you can have a discussion with the customer to discuss where these server are located and whether or not you want to add an deterministic process to which servers are used first. danny-jump:downloads djump$ nslookup > set type=srv > _ldap._tcp.dc._msdcs.arubanetworks.com ;; Truncated, retrying in TCP mode. Server: Address: #53 _ldap._tcp.dc._msdcs.arubanetworks.com _ldap._tcp.dc._msdcs.arubanetworks.com _ldap._tcp.dc._msdcs.arubanetworks.com _ldap._tcp.dc._msdcs.arubanetworks.com _ldap._tcp.dc._msdcs.arubanetworks.com _ldap._tcp.dc._msdcs.arubanetworks.com _ldap._tcp.dc._msdcs.arubanetworks.com _ldap._tcp.dc._msdcs.arubanetworks.com _Etc. Etc. Etc. Etc service = hqdc03.arubanetworks.com. service = blr-dc-1.arubanetworks.com. service = sjc-dc-05.arubanetworks.com. service = sjc-dc-09.arubanetworks.com. service = dcv1dc01.arubanetworks.com. service = chn-dc-01.arubanetworks.com. service = sjc-dc-10.arubanetworks.com. service = hqdc04.arubanetworks.com.. Making the processing deterministic can be achieved in the CPPM CLI with the following command. ad passwd- server set - s <server 1> <server 2> <server 3> <etc> To see a list of the current configured servers.. ad passwd- server list - n <domain> To load balance across DCs, different CPPM nodes in the cluster can be joined to different domain controllers. 14
15 Internal API For Dynamic Content Creation (Guest/Onboard) Most deployments will make relatively few policy changes after initial deployment is complete. This is well suited to the publisher/subscriber model, as the policy configuration is replicated to each subscriber in real- time. However, interactive use of the system to create guest accounts or provision devices with Onboard poses a different challenge. These use cases require configuration changes to be effective (Example: reset guest account password). Because of the publisher/subscriber model, configuration changes can only be performed on the publisher. However, in a complex deployment it may be necessary to direct guests and BYOD enrollment requests to a subscriber node. Note: Some functions such as a sponsor creating a guest account, they MUST login to the publisher. Same goes for MACtrac it must be done on the publisher. As an example, below we tried to change the password for a guest user on a Subscriber, notice specifically the Read Only Access message and the Update Account is greyed out and not available to be used. Figure 5 - Subscriber 'Read Only Access' when changing a guest password So, putting this in context of a CPPM High Availability cluster: If I want employees to login and create guest accounts, (and I need that in an High Availability setup) I must setup the standby publisher, plus, where appropriate use a VIP to ensure in the event of the failure the VIP is always available on the clustered- publisher (active or standby)., so the re- directs from the controllers always go to an available IP address (the VIP). In the scenario where the standby- publisher is separated by a L3 WAN boundary, the use of the VIP address between the active and standby publisher is not an option. We recommend this in an environment where the active/standby nodes are deployed within the same broadcast L2 network to simplify the availability of the active Publisher s reachable IP address. 15
16 The process that has been implemented in Guest and Onboard utilizes an internal communications channel between the nodes to process any necessary requests that involve database modification. This works as follows: 1. Subscriber node receives a request for a database modification, or for an operation that could potentially lead to a database modification (e.g. guest_register.php) 2. The request is processed and internally channeled to the current publisher node 3. Publisher receives the request and handles it (performs the database modification or generates the appropriate dynamic content) 4. The response is returned to the subscriber node 5. Subscriber node returns the response to the client With this solution, it appears as if the change is taking place on the subscriber (all URLs will appear to be pointing at the subscriber), but the change takes place on the publisher. Onboard Certificates And OCSP A device that is provisioned using Onboard will receive a client certificate that contains the device s credentials for accessing the network via EAP- TLS. One use case supported in ClearPass is for an administrator to revoke a device s client cert and deny it access to the network. This is implemented with the Online Certificate Status Protocol (OCSP), which provides a real- time status check on a particular cert s validity. In a large publisher/subscriber deployment, consideration needs to be given to how these OCSP checks should be handled, as there may be a significant number of authentications that use a client certificate, and each authentication attempt will require a separate OCSP status check. The available OCSP options in Onboard are configured under (CPPM 6.3 +) Onboard» Certificate Authorities, prior to CPPM 6.3 it was configured under Onboard» Initial Setup Certificate Authorities then the Authority Info Access option may be set to: Do not include OCSP Responder URL default option; does not encode any OCSP URL into the generated client certificate Include OCSP Responder URL includes an OCSP URL in the client certificate, where the URL is determined from the IP address of the issuing server (in the Onboard case this will be the publisher) Specify an OCSP Responder URL includes an OCSP URL in the client certificate, but allows the URL to be specified manually To avoid overloading the publisher with OCSP requests, the Include OCSP Responder URL option must not be selected. Note: Exception to this is when CPPM has been configured with more than one Onboard CA, this MUST be used since each CA will have a different OCSP URL. You cannot hard code 16
17 the URL across the board in this scenario. Our recommendation is to include the OCSP URL in the certificate and let the EAP- TLS auth method determine where to send the OCSP request. Either of the remaining options can be selected: If you select Do not include OCSP Responder URL, then CPPM must be manually configured with an appropriate OCSP URL. o This may be done by modifying the EAP- TLS authentication method, setting Verify Certificate using OCSP to Required, selecting the Override OCSP URL from Client checkbox, and then providing a suitable OCSP URL. o OCSP requests do not need to use HTTPS. o The OCSP URL provided should be a local reference to the same Policy Manager server, i.e. o This will ensure that OCSP requests are handled by the same Policy Manager server that handles the client s EAP- TLS authentication. If you select Specify an OCSP Responder URL, then a suitable URL can be included as part of each client certificate, without changing the CPPM configuration. However, there are certain requirements for this URL: o Using the IP address of a specific Policy Manager server is not recommended, as this IP will be embedded into each client certificate for the lifetime of that certificate. Changing the IP address would then require reissuing (re- provisioning) any device that has a certificate. If the server is not responding, OCSP checks will also fail. o Instead, the OCSP URL should use a DNS name that can be resolved from anywhere in the cluster. o The target of the DNS name should be a nearby Policy Manager server. All nodes (publisher and subscribers) are able to respond to OCSP requests. o Round- robin DNS can be used to load- balance OCSP requests in different regions. o This approach is not recommended for two reasons: server information is embedded into the client certificate (which is unnecessary), and this approach also imposes additional DNS configuration requirements. 17
18 OCSP Recommendations The table below summarizes the recommended settings for OCSP in a publisher/subscriber deployment: Product Setting Value Onboard Policy Manager Provisioning Settings» Authority Info Access Configuration» Authentication» Methods» EAP- TLS with OCSP Enabled Figure 6 - OCSP Recommendations Summary Do not include OCSP Responder URL Enable Override OCSP URL from Client Provide the OCSP URL Figure 7 - Setting OCSP Authentication Method Load Balancing Considerations for using third- party load balancing, e.g. for HTTP(S) captive portal, RADIUS auth/accounting have been well documented and are available in the CPPM + F5 Deployment TechNote. This along with other CPPM related TechNotes can be located here. 18
19 Auto Backup Collector aka Data Puller When CPPM administrators make changes to the CPPM Configuration its desirable and best practice to take a copy of the running configuration, so that in the event of a failure a CPPM node can be re- deployed, especially if this is the Publisher. One of CPPM s system jobs that run daily produces an automated Backup file. By default this backup Config saves the configuration database, known as the tipsdb database. As an advanced option you can configure the backup setting to be Config SessionInfo as shown below, this then saves the configuration data and the access tracker records, this file is known as the tipslogdb file and the Insightdb. To select which files are added to this backup, go to Administration - > Server Manager - > Server Configuration - > Cluster- Wide Parameters as shown below. Figure 8 - Autobackup Options These Backup files can be extremely useful whether a customer has a single or multi- node deployment. The auto- backup file can be used to restore a node to a known point. The backup task runs at 01:10am each night. Figure 9 - List of auto- backup files 19
20 These backup files are stored within the CPPM node and never exported. CPPM tracks these files and system cleanup jobs ensure they are purged to reduce storage. As of CPPM 6.4 however there is no feature to allow them to be saved/exported to off node storage (this tool is currently being scoped for a later release). However we do provide a tool as is that can be deployed on a Linux or Windows client to allow those files to be extracted and then if necessary utilized to restore a node configuration. Download the tool that is supplied, its available for Windows as a 32 or 64 bit application, for Linux we supply an RPM file. Download the appropriate files from our support site by clicking here then follow the below installation instructions for Linux or Windows. We recommend that you use the tool to extract the daily backup from the Publisher. Note that you ll have to manually manage the disk space and rotation of these backup files on the offline system. Linux Installation Install the 'rpm' file on a Linux system by issuing the following command: rpm - Uvh <filename> We have tested the installer with CentOS 5.3/5.4/6.x versions. Installer should be compatible with any Linux distributions supporting RPM installations. The configuration directory of the application is - - /usr/local/avenda/datapuller/etc After the installation, edit the "datapuller.conf" in the configuration directory to provide the following details: CPPM Server IP Address (only one node in the cluster is required) Administration username [UI username is typically 'admin'] Administration password If required create a separate External Data Puller Service account with Super Administrator privileges on the Publisher. Restart the "avenda- ext- backup" Service. /sbin/service avenda- ext- backup restart Once the service is up and running, it downloads the configuration backup files from the CPPM nodes in the cluster and stores them in the following directory. /var/avenda/datapuller/downloads/config- info/ This location can be altered by modifying the "datacollector.conf" in the config directory. 20
21 Windows Installation Extract the installer into a folder and run "setup.exe". Depending on the architecture of the system, the application installs either in C:/Program Files" or "C:/Program Files (x86) The configuration directory of the application is - - $INSTALL_ROOT/AvendaSystems/ExtDataPuller/etc After the installation, edit the "datapuller.conf" in the configuration directory to provide the following details: CPPM Server IP Address (only one node in the cluster is required) Administration username [UI username is typically 'admin'] Administration password If required create a separate External Data Puller account with Super Administrator privileges on the Publisher. Restart the "Avenda External Data Puller Client" Service with in Windows services Once the service is up and running, it downloads the configuration dumps from the CPPM nodes in the cluster and stores them in the following directory. C:/AvendaSystems/ExtDataPuller/var/downloads/config- info This location can be altered by modifying the "datacollector.conf" in the config directory. 21
22 Failover Modes What happens when something goes wrong in a publisher/subscriber deployment? Publisher Down Guest/Onboard If the publisher goes down, prior to changes introduced in CPPM 6.2 the internal proxy request will fail and a 404 not found error will be displayed for all Guest and Onboard user- facing pages. This was not the ideal situation. Starting in 6.2 CPPM moved to an API based approach between the Subscriber and the Publisher for communication specific to Guest/Onboarding, this change allowed the Subscriber nodes to handle failures between the SUB/PUB in a much more friendly way. The Standby- Publisher Any subscriber within a cluster can be manually promoted to be the active Publisher for the cluster once the Active Publisher has failed. Sometimes its pertinent that this be a manual procedure but during the time that a cluster does not have an active Publisher some functions across the cluster do not exist, e.g. Creation of Guest accounts the full list is documented later in this section What do you lose when the Publisher fails? Now, whilst some customers may be content with having to manually promote a Subscriber, demand from the field and our customers required that we provide an automated method to allow for a specific node to auto- promote itself within the cluster thus ensuring that any service degradation is limited to an absolute minimum. This feature was introduced in CPPM 6.1 to allow for a Subscriber to AUTO promote itself from a Standby Subscriber to that of the Active Publisher. Configuration of the Standby Publisher is completed in the Cluster- Wide Parameters under Administration - > Server Manager - > Server Configuration - > Cluster- Wide Parameters Note: Before you can designate a CPPM node as a Designated Publisher, the nodes have to be clustered. For more information covering the process of cluster operations, see the section below on Cluster Operation Commands. Ensure that Enable Publisher Failover is set to TRUE, in the Designated Standby Publisher drop down, then select the CPPM node required to operate as the Standby node. Note: The Standby- Publisher can still perform full Subscriber duties. However in large deployment, say when over 20 CPPM nodes are deployed the Publisher and Standby- Publisher might be dedicated nodes and not be performing ANY work beyond cluster configuration and creating Guest accounts and Onboarding users. Note: The standby publisher cannot perform publisher functions until it completes its promotion to that of the active publisher in the cluster. 22
23 Note: The default failover timer is set to 10 minutes, 5 minutes being the minimum value you can select before the standby publisher begins to promote itself to an active state. Figure 10 - Setting up the Standby Publisher As can be seen above we have select node cppm182 to be the Standby Publisher. We have in this test environment left the Failover Timer to its default of 10 minutes. Note: When a subscriber is configured as a Standby Publisher, there is no additional traffic sent to this node compared to any of the other normal Subscriber in the cluster. Publisher Failover - L2 or L3? When we initially introduced the standby- Publisher in CPPM 6.1 we enforced the rule that the Standby and Active Publishers must be within the same IP Subnet, i.e. L2- broadcast domain. For certain deployments it was possible to overcome this limitation by utilizing a GRE tunnel to provide for vlan- extension or use some other L2 extension technology like VPLS to extend the L2- domain over a L3 WAN boundary. Starting within CPPM 6.3, this restriction was relaxed. When you configure Standby and Active Publishers to be within separate IP- subnets you are presented with a warning message as shown below. Figure 11 - Configuring Standby over a L3 connection - WARNING 23
24 How the Failover Process works The Standby Publisher health- checks the Primary every 60 seconds, it makes a SQL call to the Primary Publishers Database, if this fails then after 10 [default] additional attempts [one per minute] it begins the process to promoting itself to be the Active Publisher. Prior to CPPM the node would ping (ICMP) its default GW to see if this failure was related to a network issue, if this failed it would not promote its self to an active state. If this was successful it would then ping (ICMP) the remaining nodes in the cluster and it would require that at least 50% of the nodes respond else again it would not promote, this logic tries to account for potential network related issue. However we found that in some customers the default gateway was a firewall that would not respond to ICMP and the remote CPPM nodes were protected by firewall policy to limit ICMP over the WAN, so the net result was that the Standby Publisher would never automatically promote. Starting in CPPM the logic was changed in the fail- over processing so that the process used to verify the reachability of the remote CPPM nodes now uses an outbound HTTPS call, as mentioned on page 10, you already have 443/tcp opened between nodes and it s a fundamental requirement for normal CPPM<- > communications. Utilizing this HTTPS health check provides for a more robust and predictable failover process. Mitigation strategies for this failure mode: Ensure that nodes are being monitored determine if a publisher node is no longer reachable/providing service, e.g. via SNMP host checking or similar. When a failure is detected, another subscriber node should be promoted either manually or via the automated standby- publisher feature to be the active- publisher; other subscribers will then automatically update and replicate their configuration with the new publisher, which will resolve the issue. Use a virtual IP for the publisher reduces the potential for a prolonged service outage during the time the active- publisher is down/promoting for some functions. Use the subscriber auto- promotion capability reduces potential for a failure but note that the VIP fails over significantly faster (i.e. 1 second) than a CPPM Standby- Publisher can promote itself (i.e. 8-9 minutes). Setup your NAD to point to a primary node, backup node, tertiary, etc. This only covers you for RADIUS auth/accounting traffic. Until the standby Publisher has transitioned into an active state features detailed below will not be available. Note: It is presumed and good practice that when you have a standby- publisher and also deploy Virtual IP that the standby- publisher will be paired with the active- publisher in the VIP group. 24
25 What do you lose when the Publisher fails? General CPPM & CPG Configuration changes Guest Account creation Certificate Revocation List Updates Onboarding, Certificate creation and revocation AirGroup / MACTrac enrollment MDM endpoint Polling and ingestion ClearPass Exchange Outbound enforcement Subscriber Down If a subscriber node goes down, authentication requests, guest access, and Onboard access will fail to this node, probably with a timeout error displayed to the client. Mitigation strategies for this failure mode: Ensure that nodes are being monitored determine if a subscriber node is no longer reachable/providing service, e.g. via SNMP host checking or similar. When a failure is detected, another subscriber node can be used in its place Use a virtual IP for the subscriber reduces the potential for a prolonged service outage during use. For this to work, all places that reference the subscriber must use its virtual IP address, e.g. captive portal redirection, authentication server configuration, guest registration URLs, sponsor confirmation s, etc. Setup your NAD to point to a primary node, backup node, tertiary, etc. This only covers you for RADIUS auth/accounting traffic. Note: Also possible options/recommendations: - Use load- balancing, please review the CPPM & F5 Load- Balancing TechNote for additional guidance. 25
26 Design Guidelines A ClearPass deployment using the publisher/subscriber model must satisfy the constraints described in this section. Allow HTTP/S Between Publisher and Subscribers Ensure that any firewalls that are between publisher and subscribers are configured to permit HTTPS traffic (and HTTP if required), in both directions. Refer to the Network Traffic Flows section above for a list of all protocols and port numbers that must be open. Allow Database & other Traffic Between PUB and SUB s Replication and cluster management requires that each node must be able to reach every other node on the HTTPS and database port (TCP 5432) on the management interface. Design Guidance: Ensure that any firewalls that are between publisher and subscribers are configured to permit TCP/5432 traffic, in both directions. Refer to the Network Traffic Flows section above for a list of all protocols and port numbers. Size The Publisher Node Appropriately The publisher node should be sized appropriately, as it needs to handle database writes from all subscribers simultaneously. It must also be capable of handling the number of endpoints within the cluster and be capable of processing remote work directed to it in the case of a cluster when Guest account creation and Onboarding are occurring. If any customer has any concerns about their environment specifically related to heavy workload on their Publisher/Subscriber then they should only consider the deployment of an appliance based CPPM cluster. Design Guidance: In a worldwide large- scale deployment, not all subscriber nodes will be equally busy. If the traffic pattern (busy hours) can be estimated for each subscriber node, these can be added together after adjusting for time zone differences to determine the maximum request rate that must be handled by the publisher node. 26
27 Provide Sufficient Bandwidth Between Publisher/Subscribers The traffic flows between the publisher and subscriber include: Basic monitoring of the cluster is trivial traffic. Time synchronization for clustering standard NTP traffic Policy Manager configuration changes assumed to be infrequent and therefore not a significant consumer of bandwidth Battery multi- master cache depends on the authentication load and other details of the deployment; cached information is metadata and is not expected to be very large; only replicated within the Policy Manager Zone Guest/Onboard dynamic content proxy requests this is a web page, essentially, and could be reasonably expected to average 100KB Guest/Onboard configuration changes changes to database configuration, sent as deltas and are reasonably small (in the order of 10KB) Design Guidance: In a large- scale deployment, reduced bandwidth or high latency (>200ms) on the link will provide a lower quality user experience (due to BDP for the TCP data- path, 200ms equates to 2.6Mbps of throughput based upon a 64K window) for all users of that subscriber, even though static content will be delivered locally and will appear to be near- instantaneous. For reliable operation of each subscriber, ensure that there is sufficient bandwidth available for communications with the publisher. For basic auth, we don t necessarily have a requirement for high bandwidth, BUT the number of round- trips to complete an EAP authentication (may be in excess of 10) could add up to an unpopular amount of time and delay for the end- user. Bandwidth Usage/Sizing for a CPPM Cluster To understand the bandwidth usage between nodes we undertook a study to investigate several load scenarios. For example, we wanted to understand if a node received say 100 auths/sec, either MSCHAPv2 or EAP- TLS with these being the most popular, how much traffic would this generate across the cluster. And as another example, if we generated 5 Guest accounts per second, how much cluster traffic would this generate. Replication between nodes in a cluster is carried on three ports, tcp- 80, tcp- 443 and tcp Starting in CPPM we will expose some new counter with in the Graphite reporting tool to allow this cluster traffic to be displayed and monitored. To understand the load on a network we wanted to record the baseline replication between nodes. So using the CPPM release we created a four node cluster. Three of the nodes are within the same IP- Subnet whilst the third sits behind a 10Mb emulated WAN with 50ms RTT. The CPPM environment has just the basic default configuration. We recorded via the Graphite tool the data transmitted in a 24- hour period to establish a bandwidth baseline. (We added the code to the build to facilitate this graphing). Node cppm155 in the below is the Publisher, cppm156, 157, 158 are the Subscribers. 27
28 Volumetrics of Cluster in an idle state PUBLISHER - > SUBSCRIBER The data volumes are shown below in the graph, the raw details are as follows, we noted the same volumes from the Publisher to the three Subscriber s in the cluster. Figure 12 Total Data in bytes between Publisher and Subscriber in 24- hour idle period This turns out to be 145MB of traffic port 443 and 47MB of traffic on port 8432 for a total of 192MB at an average rate of 2,633 Bytes/second (0.0026MB/second). You will be able to access these statistics to record the inter- cluster CPPM traffic on the nodes in graphite from the following interface then navigate to Graphite- > basic_perf - > [ZONE] - > [Chose the Publisher] - > nw(5432) or http(80) or https(443) Figure 13 - Publisher traffic to Subscriber over 24- hours 28
29 SUBSCRIBER - > PUBLISHER The data volumes are shown below in the graph, the raw details are as follows, we noted the same volumes from all three Subscriber s in the cluster to the Publisher. Figure 14 Total Data in Bytes between Subscriber and Publisher in 24- hour idle period This turns out to be 83MB of traffic port 443 and 47MB of traffic on port 8432 for a total of 130MB, at an average rate of 1,580 Bytes/second ( MB/second). You will be able to access these statistics to record the inter- cluster CPPM traffic on the nodes in graphite from the following interface then navigate to Graphite- > basic_perf - > [ZONE] - > [Chose a Subscriber] - > nw(5432) or http(80) or https(443) Figure 15 - Subscriber traffic to Publisher over 24- hours Note: All boxes are in the same zone, default for the above metric. 29
30 Volumetrics of Cluster in an loaded state This section to be added in V2 of this TechNote, planned for release in the coming months. 30
31 Use Zones For Geographical Regions CPPM shares a distributed cache of runtime state across all nodes in a cluster, this is commonly referred to as the Multi- Master- Cache. If zoning has not been configured then traffic flows from the Publisher <- > Subscriber and also from Subscribers <- > Subscriber. These runtime states include: Roles and Postures of connected entities Machine authentication state Session info used for COA Which endpoints are on which NAS In a deployment where a cluster spans WAN boundaries and multiple geographic zones, it is not necessary to share all of this runtime state across all nodes in the cluster. For example, endpoints present in one geographical area are not likely to authenticate or be present in another area. It is therefore more efficient from a network usage and processing perspective to restrict the sharing of such runtime state to a given geographical area. CPPM uses this runtime state information to make policy decisions across multiple transactions. Certain cached information is only replicated within the servers within a Policy Manager Zone. In a large- scale deployment with multiple different geographical areas, multiple zones should be used to reduce the amount of data that needs to be replicated over a wide- area network. Design Guidance: In a large- scale deployment, create one Policy Manager Zone for each major geographical area of the deployment. To handle RADIUS authentication traffic in each region, configure the region s networking devices with the Policy Manager nodes in the same Zone. If additional authentication servers are required for backup reasons, you can specify one or more Policy Manager servers located in a different Zone, but prefer remote servers that have the best connection (lowest latency, highest bandwidth, highest reliability). Note: Zones also effected the operation of the OnGuard Persistent agent, to fully understand the impact of CPPM Zones on OnGuard, please review the OnGuard Clustering TechNote found here. Note: You may have configured the RADIUS server on the Network Infrastructure to use remote CPPM nodes that are OUTSIDE of their primary geographic area. In this scenario the replication of the runtime state might be relevant. Consider this behavior during the design and deployment of a distributed cluster of CPPM nodes. 31
32 Use Nearest Subscriber Node Guests/Onboard clients should be directed to the nearest subscriber node. From the client s point of view, the internal API call to the publisher will be handled transparently. The best response time for static resources will be obtained if the server is nearby. Design Guidance: In a large- scale deployment, the publisher should not receive any authentications requests or Guest/Onboard request directly to help reduce the maximum amount of traffic possible (ignoring API requests from subscribers as well as the outbound replication traffic to subscribers). Use Subscriber Nodes As Workers Subscriber nodes should be used as workers that process: Authentication requests (e.g. RADIUS, TACACS+, Web- Auth) OCSP requests Static content delivery (images, CSS, JavaScript etc.) Avoid sending this worker traffic to the publisher, as it will already be servicing API requests from subscribers, handling the resulting database writes, and generating replication changes to send back to the subscribers. If Onboard is used, ensure that the EAP- TLS authentication method in Policy Manager is configured to perform localhost OCSP checks, as described under Onboard Certificates And OCSP, above. Design Guidance: In a large- scale deployment, isolate the publisher node, to allow it to handle the maximum amount of traffic possible. Use Dedicated Insight Node Collecting Netevents and updating the Insight database generates a lot of database writes (insert and update statements) that translates to heavy system IO. All ClearPass servers, whether physical or virtual, are write- limited when it comes to database I/O, due to the need to maintain reliability. To understand why, consider that most database tables will be cached in memory due to the large amount of RAM available, and will not be read- limited; but database writes are performed to a journal that must be flushed to disk for reliability reasons. In a large- scale deployment, the publisher node should already be isolated according to the advice under Use Subscriber Nodes As Workers, above. If the worker traffic sent from the subscriber nodes is expected to fully saturate the capacity of the publisher node, this would be considered a very large- scale deployment. In this case, Insight should not 32
33 be placed (enabled) on the Publisher node. However, if the publisher node has spare capacity, it can be used to support the Insight Database, but the nodes capacity and performance should be carefully monitored. Design Guidance: In a very large- scale deployment, Insight should be placed on its own dedicated node. This removes a lot of processing and IO from the publisher, allowing it to handle the maximum amount of worker traffic as possible. Insight data is valuable and could be used as part of policy evaluation. If this is the case, then there should be redundant Insight nodes enabled for fault tolerance. On top of that, performance could be impacted if there is a delay between authenticating CPPM and Insight node. Insight Setup Insight must be enabled on at least one node (two nodes is better) within a cluster. Multiple functions are dependent on Insight for them to function, e.g. MAC caching. By default Insight is NOT enabled on a node, you MUST manually enable Insight, this is performed from Administration - > Server Manager - > [node] System - > Enable Insight Figure 16 - Enabling Insight on a CPPM node Insight can be enabled on multiple nodes with in a Cluster but you need to carefully consider where you enable Insight. For every node where Insight is enabled, all the other nodes with in the cluster subscribe through a process called NetEvents to send data to this/these Insight Database s. The amount of data sent can be extremely high, so guidance from a ClearPass specialist is recommended when considering this part of a cluster deployment. Insight does NOT replicate data to any other nodes within the cluster, it is an entirely standalone Database. When you configure reporting on a node the reporting configuration is isolated to this individual node. In the above diagram you see a setting called Insight Master, this allows other nodes where Insight has been enabled to subscribe to this node s Insight Report configuration. In the event that this node fails, the reports will still be produced as the Database the reports are generated against will be similar on other nodes in the cluster, not 33
34 because the Insight Database has been replicated but because the nodes in the cluster all send a copy of their NetEvents to all nodes that have Insight enabled. Note: If you are at a remote site with a local CPPM and this node points to a remote Insight node, you cannot authenticate users if your policy includes querying Insight as an authorization source and the WAN link is down. Insight Resilience As we mentioned above Insight can be enabled on multiple nodes within your cluster, this then provides for a level of Insight resiliency. If you use Insight for Authorization within your cluster where you enable Insight is an important design consideration. Also consider that MAC caching (important part of a ClearPass Guest workflow) requires that Insight is enabled on at least a single node. Figure 17 - Insight resiliency across cluster nodes As you enable Insight on additional nodes in the cluster, CPPM automatically adds these nodes to the Insight Database authentication source definition and provides the ability to set the Backup server priority when you have more than three nodes enabled for Insight as shown above. Whenever an Insight enabled node is dropped from cluster, the corresponding node entry in Insight repository gets removed. When an Insight enabled node in a cluster is down / out of sync for more than 30mins, the insight node is moved to be the last Insight node in the fall- back list. The allows for fail- though to other Insight nodes, on the chance that if all other nodes have also failed its likely a major network outage. 34
35 Figure 18 - Enabling Insight on multiple nodes and defining the Backup source order Note: Our guidance around enabling Insight is that if you are running a CPPM network that we consider large and the worker traffic is not consuming all the Publishers resources then Insight can be enabled on the dedicated Publisher and the standby- Publisher. If you have a CPPM network that is considered very- large, where the worker traffic will consume the Publishers resources, then Insight could still be enabled on the dedicated Publisher and the standby- Publisher but these nodes should be dedicated to cluster duties, i.e. the Publisher and standby- Publisher should not be performing any authentications. Cluster Wide Parameters config settings Auto backup settings should be set to None or Config" Session log details retention 3 days Known endpoint cleanup interval review and setup if appropriate. Depends on the nature of the deployment. Unknown endpoint cleanup interval recommend that this be enabled. We suggest 7 as a default. Expired guest account cleanup interval review and set value depending on the nature of deployment. We suggest 30 days. Profiled Unknown endpoint cleanup interval we suggest 7 as the default. Audit records cleanup interval 7 days Configure Alert Notification /sms. Insight data retention 30 days 35
36 High Capacity Guest Starting with CPPM we released a special mode to allow a CPPM node to run in High Capacity Guest (HCG) mode targeted for Public Facing Enterprises environments. This mode provides the ability for a node to support double the number of Guest account regardless of whether it s an appliance or a virtual machine. Enabling HCG The option to enable this mode is performed from Administration- > Server Manager- > Server Configuration - > Cluster- Wide Parameters - >Mode Figure 19 - Enabling HCG mode Supported number of Users in HCG So a single CP- xx- 500 can support 1,000 Guests, a single CP- xx- 5K will support up to 10,000 Guest and a single CP- xx- 25K will support up to 50K Guest. HCG Cluster When nodes are enabled for this mode they can ONLY be clustered with nodes also in HCG mode. Adding a HCG node to an existing non- HCG cluster will result in a failure. 36
37 HCG - Other related information (licensing/disabled features) So when enabling HCG on a 5K node for example, it provides the ability for that node to register up to 10K Guest users. But the licenses have to be purchased and applied, we don t allow a gratuitous 2:1 licensing for these users when HCG mode is active. An additional consideration you should remember when a ClearPass node is deployed in HCG mode, is that the ClearPass Policy AAA licensing is reset on a daily bases bring it inline with the ClearPass Guest licensing. So if on a 5K node you purchase 8K Guest licenses, this would entitle you to process 8K unique endpoint/guests per day. In allowing double the number of licensed guest users we have disabled some of the other features on ClearPass. Below is a list of the restrictions for HCG mode ClearPass Onboard is disabled ClearPass OnGuard is disabled You cannot perform posture checks on endpoints You cannot perform Audit checks on endpoints The Service templates to configure 802.1X for both wired and wireless are disabled A number of EAP methods are disabled, FAST, GTC, MSCHAPv2, PEAP, TLS, TTLS Below is the warning message you are presented with when enabling HCG mode, this explains the features that are disabled when enabling HCG mode. Figure 20 Warning message when enabling HCG mode. Note: EAP- PPSK is still enabled. EAP- PPSK, private or personal PPSK is a new authentication method we added also in our CPPM release. This is specifically well suited to a CPPM node running in HCG mode. It simplifies the ability for the deployment of a Guest network that is open in that the user- id and password are the same for each user but secure as each Guest/Endpoint uses a unique per- endpoint WPA pre- shared key. The client doesn t need to support anything more than WPA- PSK. The PPSK magic is all on the network side. 37
38 Cluster Operations A cluster exists when two or more CPPM nodes are logically joined together so that they can distribute processing of Authentications/Onboarding etc. across multiple nodes. The process to join a node to another node to make a cluster or to join a new node to an existing cluster can be performed in the GUI or from within the CLI. The function to change a node from a Publisher to a Subscriber (because we only have a single active Publisher in a cluster) is always performed on the node that is going to be changed. Making a node a Subscriber from the GUI The procedure from the GUI is performed from the Administration - > Server Manager - > Server Configuration - > [Make Subscriber] Figure 21 - Make Subscriber on GUI In the above, we are about to make the node cppm183 a subscriber. We point it to the clusters Publisher and have entered the Publishers password. The Publishers password is the same as the appadmin password. During the downgrade of a node to a Subscriber the below represent the messages you d expect to see during this process, and a final message of Make subscriber complete. 38
39 Prior to the CPPM 6.4 release where we optimized this process, the process of adding nodes to the WAN can appear to be taking a long time, this is explained later in the Cluster Upgrade Section. What is actually happening in the background is the ConfigDB is being replicated. If you look at the Dashboard on the Publisher you will see the status for the new node, Sync in Progess, is shown in the Dashboard Cluster Status widget. Figure 22 - Sync in Progress for new cluster node You can also track this process in the Event Viewer following a successful addition is the below message. Figure 23 - Event Viewer success message after new cluster node added Timings to add a CPPM Node to a cluster Timings The below data is based on CPPM 5K hardware and for adding a node where the Publisher has no endpoints, i.e. it s a clean default configuration. Test1 - Local- LAN 1GB seconds Test2 - WAN 2MB with 100ms RTT seconds Test3- WAN 10MB with 100ms RTT seconds Note: The time for Test3 above is similar due to TCP BDP. Making a node a Subscriber from the CLI The process to make a node a Subscriber from the CLI is also fairly simple. You need to login to the CLI with the appadmin userid. Multiple cluster related administrative functions can be performed from here and these provide additional functionality over what can be accomplished from the GUI. 39
40 Use the command cluster make- subscriber I [publisher ip_address] (other switches are possible as shown below) to add a standalone Publisher to a cluster and make it a Subscriber. [[email protected]]# cluster make-subscriber Usage: make-subscriber -i <IP Address> [-l] [-b] -i <IP Address> -- Publisher IP Address -l -- Restore the local log database after this operation -b -- skip generating a backup before this operation After entering the IP address of the Publisher you ll see a suitable warning message about the action you re about to perform. After confirming you want to continue you have to enter the password for the Publisher, this is the cluster password, which will be the appadmin password. See below for a view of the process and the typical messages you will see in the CLI when adding a node to the cluster. 40
41 Figure 24 - Setting up cluster from CLI Then the process to downgrade the node to a Subscriber begins. It takes a while as there has to be a sync of the ConfigDB between the nodes and especially if this is performed over a WAN the process can take a while. Some timings were shown above. Figure 25 - Checking on cluster progress from CLI 41
42 Cluster Administration Managing the cluster is straightforward and typically requires little involvement. However at times problems or issues can occur with the cluster which will may require some operational involvement. In the event that a node has lost communication with the cluster for a period greater than 24- hours the node will be marked as down by the Publisher. To re- join this node to the cluster requires that the node is removed from the cluster on the Publisher and the configuration on the out- of- sync node reset. Removing the Subscriber from the cluster can be accomplished in the GUI or the CLI. In the GUI under the Administration - > Server Manager - > Server Configuration - > [Select_CPPM_Node] - > Drop Subscriber Figure 26 - Dropping Subscriber from Publisher You have to confirm the action to drop the Subscriber from the cluster. Figure 27 - Drop Subscriber confirmation message Following the confirmation message above, there are a couple of additional settings, you can select if the Database on the node you are about to drop is to be cleared and reset and also if you want the Database on the local node (Publisher) to be backed up before you begin this cluster maintenance. 42
43 Figure 28 - Drop Subscriber confirmation options Because the CPPM node has been classified as bad by the Publisher which owns the status/health of the cluster its also likely you will have to perform some intervention on the Subscriber that requires resetting. In the CLI use the command cluster reset- database command to reset the nodes configuration back to a default state, except that is for the IP addressing and the appadmin password. Following this reset, reboot the node to keep the process clean, then add the node back to the cluster as describer previously. Figure 29 - Resetting a CPPM node configuration 43
44 Cluster Upgrades Following the release of a new patch or upgrade version of the CPPM software it s highly desirable to upgrade the CPPM nodes in the cluster. Whilst we are not going to discuss the installation process, I want to discuss and guide you regarding the best way to upgrade a cluster and the considerations to be aware off. In short the recommendation is to upgrade the Publisher first, ensure that this is FULLY complete and then upgrade the subscribers in a serial process. Starting in the CPPM 6.4 software release the process of adding and upgrading nodes has been significantly improved. We have streamlined the process in several ways to improve the upgrade process. When you download the new software and install this software the unused partition/file- system is where the new version is installed and a copy of the Configuration Database is placed. When you reboot the s/w installation is completed and the remaining databases are copied and if required migrated if new Database schemas changes have been introduced in this new code release. The installation time is dependent on the size of the Database s which will be directly related to the number of endpoints etc. Whilst this portion of the upgrade is happening the remaining subscribers can still continue to process authentications etc. But no new Guest or Onboarding can occur as documented in the section What do you lose when the Publisher fails? Following the upgrade of the Publisher, you need to upgrade the Subscribers in a serial process ensuring that the upgrade has completed before starting the next upgrade. Why you ask? Well, during the upgrade process the Database on the Publisher is locked. This means several things, one that you cannot make changes to the configuration on the Publisher, again you cannot create new Guest accounts or Onboard devices. This locking of the Publishers Database has been significantly streamlined in CPPM 6.4, we only lock the configuration Database for the time it takes to generate a dump of the publisher s config Database. During the Subscriber upgrade we used to copy a lot of data in a serial process, now we have optimized a bulk transfer of the Data from the Publisher to the Subscriber. This allows for the Publishers Database to be released significantly quicker and allows for the next Subscriber to be added. Below is a copy of the messages that we now post when you add the node via the CLI, you can see some of the improvement from the below specifically what I ve highlighted is the locking/backup/release process as I ve explained above. Note: The key message below is the Config database lock released, this is the point where you can begin to add another subscriber to the cluster. Setting up local machine as a subscriber to INFO - Local checks before adding subscriber passed INFO : - Subscriber node added successfully for host=cppm-158.ns-tme.com INFO - Subscriber node entry added in publisher 44
45 INFO - Backup databases for AppPlatform INFO - Backup databases for PolicyManager INFO - Stopping services INFO - Dropped existing databases for Policy Manager INFO - Create database and schema for Policy Manager INFO - Local database setup done for Policy Manager databases INFO - Subscriber password changed INFO - Syncing up initial data... INFO - Config database temporarily locked for updates INFO : - Backup databases for AppPlatform INFO : - Backup databases for PolicyManager INFO - Config database lock released INFO - Subscriber now replicating from publisher INFO - Retaining local node certificate INFO - Subscriber replication and node setup complete INFO - Notify publisher that adding subscriber is complete INFO - Subscriber added successfully INFO - Restarting Policy Manager admin server Figure 30 - CLI messages for adding a node As we ve just explained the upgrading of the subscribers must be completed as soon as possible after the Publisher has been upgraded as its likely that following the upgrade of the Publisher, the Subscribers will be out of sync with the Publisher. Nodes that are out of Sync with the Publisher will not be able to receive changes made to the clusters configuration, be that new or amended service policies or new Guest Accounts. The best way to see if the upgrade has completed is to ensure the message below is seen in the Event Viewer on the Publisher or that the above messages as observed in the CLI. Figure 31 - Confirmation that an upgrade is completed Depending on the type of software upgrade you are doing on the Publisher it is possible that the Subscribers will not go out of sync. Either way the recommendation is to upgrade the remaining nodes within the cluster ASAP. 45
46 What follows are some other additional good practice processes that are valid but not absolutely necessary. Stopping the RADIUS server on the node before you begin the upgrade. This allows for a clean take- down of the node and no NAS devices will send authentications to it expecting a response. If this is completed a couple of minutes before the upgrade begins the NAS devices should have marked this RADIUS server unavailable. Also, we recommend disabling auto- backup and standby publisher setting needs to be disabled as well prior to starting an s/w upgrade. Below is taken from the CPPM User Guide. Select any of the following auto backup configuration options: Off - Select this to not perform periodic backups. Note: Select Off before upgrading ClearPass Policy Manager to avoid the interference between Auto backup and migration process. Config - Perform a periodic backup of the configuration database only. This is the default auto backup configuration option. Config SessionInfo - Perform a backup of the configuration database and the session log database. Cluster Upgrade Tool We have recently made available a cluster upgrade patch that will simplify the upgrading of large CPPM multi- node clusters. The tool was written to take advantage of some of the changes we made in the underlying code- release. Some of these are discussed in the section above that relate to the processes used when adding nodes to CPPM clusters. The tool is available for CPPM versions 6.3 and 6.2. It automates a vast amount of the tasks required to upgrade nodes, e.g. it will download the upgrade image to the central Publisher and then push the code update as required to the end- nodes. The tool is released as a patch update for ClearPass 6.2 and 6.3 versions. It can be downloaded and installed either through CPPM s Software Updates portal, or from the Aruba Support portal. Once the tool is installed you can access the tool at There is a special TechNote that covers the cluster upgrade tool in detail. It can be located here 46
47 Scaling Limitations Different components of a ClearPass deployment will scale differently, due to the design of the publisher/subscriber model. Certain components are listed below with the limits to scaling identified. Authentication capacity: scales linearly in the number of subscriber nodes. Add more nodes to provide additional capacity to service authentication requests. Logging capacity: scales linearly in the number of subscriber nodes, as each node handles its own logging. Insight reports: does not scale with additional nodes as it is centralized. Use a separate Insight node sufficient to handle the incoming Netevents traffic from all nodes in the cluster. The publisher node should not be used as the Insight reporting node in a very large- scale deployment. Configuration changes (Policy Manager): these are assumed to be infrequent and therefore are not a significant limit to scaling, as the total size of the configuration set will be bounded. Replication load on publisher: scales linearly in the number of subscriber nodes. The replication is assumed to be relatively efficient as only deltas are sent. Configuration changes (Guest/Onboard): does not scale with additional nodes as it is centralized. Requires the publisher be scaled to support write traffic from the maximum number of subscribers that would be active concurrently. 47
48 Virtual IP Considerations Using a Virtual IP address allows for the deployment of a highly available pair of servers. This is intended to reduce the amount of downtime in the event of a server failure: if one of the servers in a HA pair fails, the other server can take over the virtual IP address and continue providing service to clients. Particular useful if the NAS devices are trying to process basic RADIUS authentications to a CPPM node. However this does not eliminate the failure modes described above. Consider the case where the publisher node that currently has the virtual IP address fails. The backup publisher node cannot take over immediately (in the sense of it creating Guest accounts etc,) as the failure may be transient and the minimum time it takes for a standby- Publisher to become active is about 8 minutes, this duration is made up of 5 minutes (5 attempts) to connect to the active- Publisher s Database then about 3-4 minutes for the node to promote itself in to an active state. There will always be a delay before the virtual IP address is back in service, in the sense that the IP address NAS clients are communicating with is able to process more than basic Database read actions i.e. RADIUS authentication. During this window, requests from subscribers to write to the Publishers Database will fail as there will be no publisher responding to the virtual IP address than can write to the Database. 48
ARUBA WIRELESS AND CLEARPASS 6 INTEGRATION GUIDE. Technical Note
ARUBA WIRELESS AND CLEARPASS 6 INTEGRATION GUIDE Technical Note Copyright 2013 Aruba Networks, Inc. Aruba Networks trademarks include, Aruba Networks, Aruba Wireless Networks, the registered Aruba the
Cisco Application Networking Manager Version 2.0
Cisco Application Networking Manager Version 2.0 Cisco Application Networking Manager (ANM) software enables centralized configuration, operations, and monitoring of Cisco data center networking equipment
Enterprise Manager. Version 6.2. Installation Guide
Enterprise Manager Version 6.2 Installation Guide Enterprise Manager 6.2 Installation Guide Document Number 680-028-014 Revision Date Description A August 2012 Initial release to support version 6.2.1
NMS300 Network Management System
NMS300 Network Management System User Manual June 2013 202-11289-01 350 East Plumeria Drive San Jose, CA 95134 USA Support Thank you for purchasing this NETGEAR product. After installing your device, locate
vcloud Air - Virtual Private Cloud OnDemand Networking Guide
vcloud Air - Virtual Private Cloud OnDemand Networking Guide vcloud Air This document supports the version of each product listed and supports all subsequent versions until the document is replaced by
OnCommand Performance Manager 1.1
OnCommand Performance Manager 1.1 Installation and Setup Guide For Red Hat Enterprise Linux NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501
Configuring Failover
Configuring Failover 2015 Bomgar Corporation. All rights reserved worldwide. BOMGAR and the BOMGAR logo are trademarks of Bomgar Corporation; other trademarks shown are the property of their respective
ARUBA CLEARPASS HARDENING GUIDE
ARUBA CLEARPASS HARDENING GUIDE March 2015 Copyright Copyright 2015 Aruba Networks, Inc. Aruba Networks trademarks include AirWave, Aruba Networks, Aruba Wireless Networks, the registered Aruba the Mobile
VMware vcloud Air Networking Guide
vcloud Air This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions of this document,
User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream
User Manual Onsight Management Suite Version 5.1 Another Innovation by Librestream Doc #: 400075-06 May 2012 Information in this document is subject to change without notice. Reproduction in any manner
Release Notes. LiveVault. Contents. Version 7.65. Revision 0
R E L E A S E N O T E S LiveVault Version 7.65 Release Notes Revision 0 This document describes new features and resolved issues for LiveVault 7.65. You can retrieve the latest available product documentation
Symantec Endpoint Protection 11.0 Architecture, Sizing, and Performance Recommendations
Symantec Endpoint Protection 11.0 Architecture, Sizing, and Performance Recommendations Technical Product Management Team Endpoint Security Copyright 2007 All Rights Reserved Revision 6 Introduction This
GRAVITYZONE HERE. Deployment Guide VLE Environment
GRAVITYZONE HERE Deployment Guide VLE Environment LEGAL NOTICE All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, including
BlackBerry Enterprise Service 10. Version: 10.2. Configuration Guide
BlackBerry Enterprise Service 10 Version: 10.2 Configuration Guide Published: 2015-02-27 SWD-20150227164548686 Contents 1 Introduction...7 About this guide...8 What is BlackBerry Enterprise Service 10?...9
VMware vcloud Air - Disaster Recovery User's Guide
VMware vcloud Air - Disaster Recovery User's Guide vcloud Air This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition.
642 523 Securing Networks with PIX and ASA
642 523 Securing Networks with PIX and ASA Course Number: 642 523 Length: 1 Day(s) Course Overview This course is part of the training for the Cisco Certified Security Professional and the Cisco Firewall
Deployment Guide. Deploying F5 BIG-IP Global Traffic Manager on VMware vcloud Hybrid Service
Deployment Guide Deploying F5 BIG-IP Global Traffic Manager on VMware vcloud Hybrid Service A. Introduction VMware vcloud Hybrid Service is an effective, flexible and reliable platform for enterprise customers
vsphere Replication for Disaster Recovery to Cloud
vsphere Replication for Disaster Recovery to Cloud vsphere Replication 5.8 This document supports the version of each product listed and supports all subsequent versions until the document is replaced
Identikey Server Performance and Deployment Guide 3.1
Identikey Server Performance and Deployment Guide 3.1 Disclaimer of Warranties and Limitations of Liabilities Disclaimer of Warranties and Limitations of Liabilities The Product is provided on an 'as is'
VMware vcenter Log Insight Getting Started Guide
VMware vcenter Log Insight Getting Started Guide vcenter Log Insight 1.5 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by
vsphere Replication for Disaster Recovery to Cloud
vsphere Replication for Disaster Recovery to Cloud vsphere Replication 6.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced
Installing and Using the vnios Trial
Installing and Using the vnios Trial The vnios Trial is a software package designed for efficient evaluation of the Infoblox vnios appliance platform. Providing the complete suite of DNS, DHCP and IPAM
NetSpective Global Proxy Configuration Guide
NetSpective Global Proxy Configuration Guide Table of Contents NetSpective Global Proxy Deployment... 3 Configuring NetSpective for Global Proxy... 5 Restrict Admin Access... 5 Networking... 6 Apply a
VMware vrealize Automation
VMware vrealize Automation Reference Architecture Version 6.0 and Higher T E C H N I C A L W H I T E P A P E R Table of Contents Overview... 4 What s New... 4 Initial Deployment Recommendations... 4 General
GlobalSCAPE DMZ Gateway, v1. User Guide
GlobalSCAPE DMZ Gateway, v1 User Guide GlobalSCAPE, Inc. (GSB) Address: 4500 Lockhill-Selma Road, Suite 150 San Antonio, TX (USA) 78249 Sales: (210) 308-8267 Sales (Toll Free): (800) 290-5054 Technical
Installing and Configuring vcloud Connector
Installing and Configuring vcloud Connector vcloud Connector 2.7.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new
Burst Technology bt-loganalyzer SE
Burst Technology bt-loganalyzer SE Burst Technology Inc. 9240 Bonita Beach Rd, Bonita Springs, FL 34135 CONTENTS WELCOME... 3 1 SOFTWARE AND HARDWARE REQUIREMENTS... 3 2 SQL DESIGN... 3 3 INSTALLING BT-LOGANALYZER...
NETASQ MIGRATING FROM V8 TO V9
UTM Firewall version 9 NETASQ MIGRATING FROM V8 TO V9 Document version: 1.1 Reference: naentno_migration-v8-to-v9 INTRODUCTION 3 Upgrading on a production site... 3 Compatibility... 3 Requirements... 4
Troubleshooting BlackBerry Enterprise Service 10 version 10.1.1 726-08745-123. Instructor Manual
Troubleshooting BlackBerry Enterprise Service 10 version 10.1.1 726-08745-123 Instructor Manual Published: 2013-07-02 SWD-20130702091645092 Contents Advance preparation...7 Required materials...7 Topics
Copyright 2012 Trend Micro Incorporated. All rights reserved.
Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice. Before installing and using the software, please review the readme files,
Virtual Appliance Setup Guide
The Virtual Appliance includes the same powerful technology and simple Web based user interface found on the Barracuda Web Application Firewall hardware appliance. It is designed for easy deployment on
DameWare Server. Administrator Guide
DameWare Server Administrator Guide About DameWare Contact Information Team Contact Information Sales 1.866.270.1449 General Support Technical Support Customer Service User Forums http://www.dameware.com/customers.aspx
Deploying F5 with Microsoft Active Directory Federation Services
F5 Deployment Guide Deploying F5 with Microsoft Active Directory Federation Services This F5 deployment guide provides detailed information on how to deploy Microsoft Active Directory Federation Services
Web Sites, Virtual Machines, Service Management Portal and Service Management API Beta Installation Guide
Web Sites, Virtual Machines, Service Management Portal and Service Management API Beta Installation Guide Contents Introduction... 2 Environment Topology... 2 Virtual Machines / System Requirements...
ClearPass 6.5.0. Release Notes
ClearPass 6.5.0 Release Notes Copyright 2015 Aruba Networks, Inc. Aruba Networks trademarks include, Aruba Networks, Aruba Wireless Networks, the registered Aruba the Mobile Edge Company logo, Aruba Mobility
Virtual Appliance Setup Guide
Virtual Appliance Setup Guide 2015 Bomgar Corporation. All rights reserved worldwide. BOMGAR and the BOMGAR logo are trademarks of Bomgar Corporation; other trademarks shown are the property of their respective
Resonate Central Dispatch
Resonate Central Dispatch Microsoft Exchange 2010 Resonate, Inc. Tel. + 1.408.545.5535 Fax + 1.408.545.5502 www.resonate.com Copyright 2013 Resonate, Inc. All rights reserved. Resonate Incorporated and
VMware vcloud Automation Center 6.1
VMware vcloud Automation Center 6.1 Reference Architecture T E C H N I C A L W H I T E P A P E R Table of Contents Overview... 4 What s New... 4 Initial Deployment Recommendations... 4 General Recommendations...
Quick Start Guide. for Installing vnios Software on. VMware Platforms
Quick Start Guide for Installing vnios Software on VMware Platforms Copyright Statements 2010, Infoblox Inc. All rights reserved. The contents of this document may not be copied or duplicated in any form,
Getting Started with ESXi Embedded
ESXi 4.1 Embedded vcenter Server 4.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent
Mobile Device Management Version 8. Last updated: 17-10-14
Mobile Device Management Version 8 Last updated: 17-10-14 Copyright 2013, 2X Ltd. http://www.2x.com E mail: [email protected] Information in this document is subject to change without notice. Companies names
WhatsUp Gold v16.3 Installation and Configuration Guide
WhatsUp Gold v16.3 Installation and Configuration Guide Contents Installing and Configuring WhatsUp Gold using WhatsUp Setup Installation Overview... 1 Overview... 1 Security considerations... 2 Standard
Configuration Guide. BlackBerry Enterprise Service 12. Version 12.0
Configuration Guide BlackBerry Enterprise Service 12 Version 12.0 Published: 2014-12-19 SWD-20141219132902639 Contents Introduction... 7 About this guide...7 What is BES12?...7 Key features of BES12...
RealPresence Platform Director
RealPresence CloudAXIS Suite Administrators Guide Software 1.3.1 GETTING STARTED GUIDE Software 2.0 June 2015 3725-66012-001B RealPresence Platform Director Polycom, Inc. 1 RealPresence Platform Director
About the VM-Series Firewall
About the VM-Series Firewall Palo Alto Networks VM-Series Deployment Guide PAN-OS 6.0 Contact Information Corporate Headquarters: Palo Alto Networks 4401 Great America Parkway Santa Clara, CA 95054 http://www.paloaltonetworks.com/contact/contact/
vsphere Upgrade vsphere 6.0 EN-001721-03
vsphere 6.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent editions of this document,
TechNote - Deploying CPPM with F5 BIG-IP Local Traffic Manager (LTM)
Tech Note: TechNote - Deploying CPPM with F5 BIG-IP Local Traffic Manager (LTM) Version Date Modified By Comments 0.1 July 2014 Danny Jump Early Draft Version 0.2 / 0.3 07/11/2014 Con Stathis Added sections
ACS 5.x and later: Integration with Microsoft Active Directory Configuration Example
ACS 5.x and later: Integration with Microsoft Active Directory Configuration Example Document ID: 113571 Contents Introduction Prerequisites Requirements Components Used Conventions Background Information
NEFSIS DEDICATED SERVER
NEFSIS TRAINING SERIES Nefsis Dedicated Server version 5.2.0.XXX (DRAFT Document) Requirements and Implementation Guide (Rev5-113009) REQUIREMENTS AND INSTALLATION OF THE NEFSIS DEDICATED SERVER Nefsis
VMware vrealize Automation
VMware vrealize Automation Reference Architecture Version 6.0 or Later T E C H N I C A L W H I T E P A P E R J U N E 2 0 1 5 V E R S I O N 1. 5 Table of Contents Overview... 4 What s New... 4 Initial Deployment
How to Backup and Restore a VM using Veeam
How to Backup and Restore a VM using Veeam Table of Contents Introduction... 3 Assumptions... 3 Add ESXi Server... 4 Backup a VM... 6 Restore Full VM... 12 Appendix A: Install Veeam Backup & Replication
Password Reset PRO INSTALLATION GUIDE
Password Reset PRO INSTALLATION GUIDE This guide covers the new features and settings available in Password Reset PRO. Please read this guide completely to ensure a trouble-free installation. March 2009
There are numerous ways to access monitors:
Remote Monitors REMOTE MONITORS... 1 Overview... 1 Accessing Monitors... 1 Creating Monitors... 2 Monitor Wizard Options... 11 Editing the Monitor Configuration... 14 Status... 15 Location... 17 Alerting...
Interworks. Interworks Cloud Platform Installation Guide
Interworks Interworks Cloud Platform Installation Guide Published: March, 2014 This document contains information proprietary to Interworks and its receipt or possession does not convey any rights to reproduce,
DEPLOYMENT GUIDE Version 1.1. Configuring BIG-IP WOM with Oracle Database Data Guard, GoldenGate, Streams, and Recovery Manager
DEPLOYMENT GUIDE Version 1.1 Configuring BIG-IP WOM with Oracle Database Data Guard, GoldenGate, Streams, and Recovery Manager Table of Contents Table of Contents Configuring BIG-IP WOM with Oracle Database
Cisco AnyConnect Secure Mobility Solution Guide
Cisco AnyConnect Secure Mobility Solution Guide This document contains the following information: Cisco AnyConnect Secure Mobility Overview, page 1 Understanding How AnyConnect Secure Mobility Works, page
D-Link Central WiFiManager Configuration Guide
Table of Contents D-Link Central WiFiManager Configuration Guide Introduction... 3 System Requirements... 3 Access Point Requirement... 3 Latest CWM Modules... 3 Scenario 1 - Basic Setup... 4 1.1. Install
Apache CloudStack 4.x (incubating) Network Setup: excerpt from Installation Guide. Revised February 28, 2013 2:32 pm Pacific
Apache CloudStack 4.x (incubating) Network Setup: excerpt from Installation Guide Revised February 28, 2013 2:32 pm Pacific Apache CloudStack 4.x (incubating) Network Setup: excerpt from Installation Guide
Remote Application Server Version 14. Last updated: 25-02-15
Remote Application Server Version 14 Last updated: 25-02-15 Information in this document is subject to change without notice. Companies, names, and data used in examples herein are fictitious unless otherwise
Data Collection and Analysis: Get End-to-End Security with Cisco Connected Analytics for Network Deployment
White Paper Data Collection and Analysis: Get End-to-End Security with Cisco Connected Analytics for Network Deployment Cisco Connected Analytics for Network Deployment (CAND) is Cisco hosted, subscription-based
Secure Networks for Process Control
Secure Networks for Process Control Leveraging a Simple Yet Effective Policy Framework to Secure the Modern Process Control Network An Enterasys Networks White Paper There is nothing more important than
TANDBERG MANAGEMENT SUITE 10.0
TANDBERG MANAGEMENT SUITE 10.0 Installation Manual Getting Started D12786 Rev.16 This document is not to be reproduced in whole or in part without permission in writing from: Contents INTRODUCTION 3 REQUIREMENTS
HP Device Manager 4.6
Technical white paper HP Device Manager 4.6 Installation and Update Guide Table of contents Overview... 3 HPDM Server preparation... 3 FTP server configuration... 3 Windows Firewall settings... 3 Firewall
VEEAM ONE 8 RELEASE NOTES
VEEAM ONE 8 RELEASE NOTES This Release Notes document provides last-minute information about Veeam ONE 8 Update 2, including system requirements, installation instructions as well as relevant information
Architecture and Data Flow Overview. BlackBerry Enterprise Service 10 721-08877-123 Version: 10.2. Quick Reference
Architecture and Data Flow Overview BlackBerry Enterprise Service 10 721-08877-123 Version: Quick Reference Published: 2013-11-28 SWD-20131128130321045 Contents Key components of BlackBerry Enterprise
Privileged Access Management Upgrade Guide
Privileged Access Management Upgrade Guide 2015 Bomgar Corporation. All rights reserved worldwide. BOMGAR and the BOMGAR logo are trademarks of Bomgar Corporation; other trademarks shown are the property
Palo Alto Networks User-ID Services. Unified Visitor Management
Palo Alto Networks User-ID Services Unified Visitor Management Copyright 2011 Aruba Networks, Inc. Aruba Networks trademarks include Airwave, Aruba Networks, Aruba Wireless Networks, the registered Aruba
User Guide for VMware Adapter for SAP LVM VERSION 1.2
User Guide for VMware Adapter for SAP LVM VERSION 1.2 Table of Contents Introduction to VMware Adapter for SAP LVM... 3 Product Description... 3 Executive Summary... 3 Target Audience... 3 Prerequisites...
Configuration Guide BES12. Version 12.2
Configuration Guide BES12 Version 12.2 Published: 2015-07-07 SWD-20150630131852557 Contents About this guide... 8 Getting started... 9 Administrator permissions you need to configure BES12... 9 Obtaining
Transparent Identification of Users
Transparent Identification of Users Websense Web Security Solutions v7.5, v7.6 Transparent Identification of Users 1996 2011, Websense, Inc. All rights reserved. 10240 Sorrento Valley Rd., San Diego, CA
How To Integrate An Ipm With Airwatch With Big Ip On A Server With A Network (F5) On A Network With A Pb (Fiv) On An Ip Server On A Cloud (Fv) On Your Computer Or Ip
F5 Networks, Inc. F5 Recommended Practices for BIG-IP and AirWatch MDM Integration Contents Introduction 4 Purpose 5 Requirements 6 Prerequisites 6 AirWatch 6 F5 BIG-IP 6 Network Topology 7 Big-IP Configuration
ClearPass Policy Manager 6.1
ClearPass Policy Manager 6.1 Quick Start Guide Copyright Information Copyright 2013 Aruba Networks, Inc. Aruba Networks trademarks include the Aruba Networks logo, Aruba Networks, Aruba Wireless Networks,
Configuration Guide BES12. Version 12.1
Configuration Guide BES12 Version 12.1 Published: 2015-04-22 SWD-20150422113638568 Contents Introduction... 7 About this guide...7 What is BES12?...7 Key features of BES12... 8 Product documentation...
StarWind Virtual SAN Installation and Configuration of Hyper-Converged 2 Nodes with Hyper-V Cluster
#1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Installation and Configuration of Hyper-Converged 2 Nodes with MARCH 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the
Product Manual. MDM On Premise Installation Version 8.1. Last Updated: 06/07/15
Product Manual MDM On Premise Installation Version 8.1 Last Updated: 06/07/15 Parallels IP Holdings GmbH Vordergasse 59 8200 Schaffhausen Switzerland Tel: + 41 52 632 0411 Fax: + 41 52 672 2010 www.parallels.com
The SSL device also supports the 64-bit Internet Explorer with new ActiveX loaders for Assessment, Abolishment, and the Access Client.
WatchGuard SSL v3.2 Release Notes Supported Devices SSL 100 and 560 WatchGuard SSL OS Build 355419 Revision Date January 28, 2013 Introduction WatchGuard is pleased to announce the release of WatchGuard
Load Balancing Microsoft Sharepoint 2010 Load Balancing Microsoft Sharepoint 2013. Deployment Guide
Load Balancing Microsoft Sharepoint 2010 Load Balancing Microsoft Sharepoint 2013 Deployment Guide rev. 1.4.2 Copyright 2015 Loadbalancer.org, Inc. 1 Table of Contents About this Guide... 3 Appliances
F-Secure Messaging Security Gateway. Deployment Guide
F-Secure Messaging Security Gateway Deployment Guide TOC F-Secure Messaging Security Gateway Contents Chapter 1: Deploying F-Secure Messaging Security Gateway...3 1.1 The typical product deployment model...4
Citrix EdgeSight Administrator s Guide. Citrix EdgeSight for Endpoints 5.3 Citrix EdgeSight for XenApp 5.3
Citrix EdgeSight Administrator s Guide Citrix EdgeSight for Endpoints 5.3 Citrix EdgeSight for enapp 5.3 Copyright and Trademark Notice Use of the product documented in this guide is subject to your prior
Set Up Panorama. Palo Alto Networks. Panorama Administrator s Guide Version 6.0. Copyright 2007-2015 Palo Alto Networks
Set Up Panorama Palo Alto Networks Panorama Administrator s Guide Version 6.0 Contact Information Corporate Headquarters: Palo Alto Networks 4401 Great America Parkway Santa Clara, CA 95054 www.paloaltonetworks.com/company/contact-us
Guide to the LBaaS plugin ver. 1.0.2 for Fuel
Guide to the LBaaS plugin ver. 1.0.2 for Fuel Load Balancing plugin for Fuel LBaaS (Load Balancing as a Service) is currently an advanced service of Neutron that provides load balancing for Neutron multi
How To Install Powerpoint 6 On A Windows Server With A Powerpoint 2.5 (Powerpoint) And Powerpoint 3.5.5 On A Microsoft Powerpoint 4.5 Powerpoint (Powerpoints) And A Powerpoints 2
DocAve 6 Service Pack 1 Installation Guide Revision C Issued September 2012 1 Table of Contents About the Installation Guide... 4 Submitting Documentation Feedback to AvePoint... 4 Before You Begin...
Grandstream Networks, Inc. UCM6100 Security Manual
Grandstream Networks, Inc. UCM6100 Security Manual Index Table of Contents OVERVIEW... 3 WEB UI ACCESS... 4 UCM6100 HTTP SERVER ACCESS... 4 PROTOCOL TYPE... 4 USER LOGIN... 4 LOGIN TIMEOUT... 5 TWO-LEVEL
Deployment Guide. AX Series with Microsoft Office SharePoint Server
Deployment Guide AX Series with Microsoft Office SharePoint Server Table of Contents DEPLOYMENT GUIDE AX Series with Microsoft Office SharePoint Server Introduction... 1 Prerequisites & Assumptions...
msuite5 & mdesign Installation Prerequisites
CommonTime Limited msuite5 & mdesign Installation Prerequisites Administration considerations prior to installing msuite5 and mdesign. 7/7/2011 Version 2.4 Overview... 1 msuite version... 1 SQL credentials...
ZEN LOAD BALANCER EE v3.02 DATASHEET The Load Balancing made easy
ZEN LOAD BALANCER EE v3.02 DATASHEET The Load Balancing made easy OVERVIEW The global communication and the continuous growth of services provided through the Internet or local infrastructure require to
Acronis and Acronis Secure Zone are registered trademarks of Acronis International GmbH.
1 Copyright Acronis International GmbH, 2002-2016 Copyright Statement Copyright Acronis International GmbH, 2002-2016. All rights reserved. Acronis and Acronis Secure Zone are registered trademarks of
DEPLOYMENT GUIDE Version 1.0. Deploying the BIG-IP Edge Gateway for Layered Security and Acceleration Services
DEPLOYMENT GUIDE Version 1.0 Deploying the BIG-IP Edge Gateway for Layered Security and Acceleration Services Table of Contents Table of Contents Using the BIG-IP Edge Gateway for layered security and
Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario
Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario Version 7.2 November 2015 Last modified: November 3, 2015 2015 Nasuni Corporation All Rights Reserved Document Information Testing
Setup Guide Access Manager 3.2 SP3
Setup Guide Access Manager 3.2 SP3 August 2014 www.netiq.com/documentation Legal Notice THIS DOCUMENT AND THE SOFTWARE DESCRIBED IN THIS DOCUMENT ARE FURNISHED UNDER AND ARE SUBJECT TO THE TERMS OF A LICENSE
WhatsUpGold. v3.0. WhatsConnected User Guide
WhatsUpGold v3.0 WhatsConnected User Guide Contents CHAPTER 1 Welcome to WhatsConnected Finding more information and updates... 2 Sending feedback... 3 CHAPTER 2 Installing and Configuring WhatsConnected
Barracuda Link Balancer
Barracuda Networks Technical Documentation Barracuda Link Balancer Administrator s Guide Version 2.2 RECLAIM YOUR NETWORK Copyright Notice Copyright 2004-2011, Barracuda Networks www.barracuda.com v2.2-110503-01-0503
www.novell.com/documentation Server Installation ZENworks Mobile Management 2.7.x August 2013
www.novell.com/documentation Server Installation ZENworks Mobile Management 2.7.x August 2013 Legal Notices Novell, Inc., makes no representations or warranties with respect to the contents or use of this
Storage Sync for Hyper-V. Installation Guide for Microsoft Hyper-V
Installation Guide for Microsoft Hyper-V Egnyte Inc. 1890 N. Shoreline Blvd. Mountain View, CA 94043, USA Phone: 877-7EGNYTE (877-734-6983) www.egnyte.com 2013 by Egnyte Inc. All rights reserved. Revised
Accops HyWorks v2.5. Quick Start Guide. Last Update: 4/18/2016
Accops HyWorks v2.5 Quick Start Guide Last Update: 4/18/2016 2016 Propalms Technologies Pvt. Ltd. All rights reserved. The information contained in this document represents the current view of Propalms
Configuration Guide. Websense Web Security Solutions Version 7.8.1
Websense Web Security Solutions Version 7.8.1 To help you make the transition to Websense Web Security or Web Security Gateway, this guide covers the basic steps involved in setting up your new solution
Installation and Configuration Guide for Windows and Linux
Installation and Configuration Guide for Windows and Linux vcenter Operations Manager 5.0.3 This document supports the version of each product listed and supports all subsequent versions until the document
VMware vsphere 5.0 Evaluation Guide
VMware vsphere 5.0 Evaluation Guide Auto Deploy TECHNICAL WHITE PAPER Table of Contents About This Guide.... 4 System Requirements... 4 Hardware Requirements.... 4 Servers.... 4 Storage.... 4 Networking....
3M Command Center. Installation and Upgrade Guide
3M Command Center Installation and Upgrade Guide Copyright 3M, 2015. All rights reserved., 78-8129-3760-1d 3M is a trademark of 3M. Microsoft, Windows, Windows Server, Windows Vista and SQL Server are