A DEEP FOUNDATION COMPARISON: DRIVEN vs BORED PILES. Professor s Driven Pile Institute Logan, UT June 26, 2013
|
|
|
- Randall Cole
- 9 years ago
- Views:
Transcription
1 A DEEP FOUNDATION COMPARISON: DRIVEN vs BORED PILES Presented By: Professor s Driven Pile Institute Logan, UT June 26, 2013 Billy Camp, PE, D.GE Technical Principal/Vice President S&ME, Inc. Charleston, SC [email protected] PDPI June 22, 2011 Logan, UT
2 COMMON DEEP FOUNDATIONS (US Practice for Support of Structures) DRIVEN Concrete 10, 12, 14, 18, 24, 30 and 36 square PSC 36 to 66 Cylinder Steel 10, 12 and 14 HP (16 and 18 now being rolled) 8 to 36 + pipe (open or closed) Wood 7 to 10 tip diameter, L<65 Composite PSC top with HP, W, or Pipe section bottom BORED Drilled Shafts 3 to 12 Micropiles 5 to 12 Drilled Displacement 14 to 18 Continuous Flight Auger (CFA) 12 to 24 PDPI
3 UNIT RESISTANCE DRIVEN Displacement or Low Displacement: Stress Increase strength increase and stiffer response. Disturbance: setup - resistance increase with time. PDPI
4 Driven Pile Time Dependency
5 UNIT RESISTANCE DRIVEN Cont. Disturbance: relaxation decreased resistance with time. Disturbance: irrecoverable in some formations (e.g., calcareous sands) Construction method effects rarely a factor. PDPI
6 Driven Piles Installation Method PDPI
7 DRILLED SHAFTS UNIT RESISTANCE Excavation reduces stresses strength decrease and softer response. Roughness small scale (concrete vs steel) and larger scale (irregular surface). PDPI
8
9 UNIT RESISTANCE DRILLED SHAFTS Cont. Reduced Disturbance: beneficial in some formations (e.g., calcareous sands) Construction method effects can be very important. PDPI
10 Drilled Shaft Polymer vs Mineral Slurry From Brown et al 2002
11 Fundamental Difference Point of Manufacture Driven Piles: at steel mill, prestressed yard, or wood yard under factory controlled conditions Uniform, consistent product delivered to the site Highly efficient Drilled Shafts: manufactured on site and in place Complex construction process Significant QA/QC requirements in the field PDPI
12 Driven Pile Manufacturing
13 Driven Pile Construction Equipment Crane Hammer & Leads Powerpack (hydraulic or air hammer) Helper Crane (opt.)
14 Pile Driving Equipment
15 Drilled Shaft Manufacturing Excavation Excavation Stability Excavation Cleaning Steel Reinforcement Fabrication Placement of Reinforcing Cage Concrete Delivery Concrete Placement
16 Drilled Shaft Construction Equipment Drill Rig Helper Crane Spoil Handling (loader, skip pan, etc.) Casing (opt) Slurry Handling (opt) Cage Erection Template Concrete Truck Concrete Pump Truck (opt)
17 June 22, 2011 Logan, UT Drilled Shaft Construction Process
18 Consequently Driven piles are generally less expensive General contractors can often self-perform with driven piles Drilled shafts usually require a specialty foundation subcontractor Since drilled shaft QA/QC is all done in the field, oversight & inspection is more complex but critical
19 Constructability Issues Driven Piles Length revisions are relatively easy (splicing or cut-off of steel piles, cutoff of PSC piles). Minimum penetration requirements (e.g., consideration of scour and liquefaction potential, fixity, uplift) may be hard to meet Drilled Shafts Length revisions are feasible but take time (cage modifications) Minimum penetration requirements are typically not an issue PDPI
20 Construction Feedback Driven Piles Driving resistance Transferred hammer energy/hammer performance Driving stresses Pile integrity Capacity Drilled Shafts Auger cuttings Observation of bottom cleanliness (sometimes) Concrete volume Shaft profile/geometry (possible but not widely done) PDPI
21 Redundancy & Loading Issues Driven Piles in general Smaller elements Lower capacity Lower cost More elements used Highly redundant Drilled Shafts in general Bigger elements Higher capacity Higher cost Fewer elements used Little to no redundancy PDPI
22 June 22, 2011 Logan, UT
23 June 22, 2011 Logan, UT
24 June 22, 2011 Logan, UT
25 Integrity & Reliability Issues Driven Piles Delivered free of defects May be damaged during or infrequently, after installation Damage is typically easily detectable A Driven Pile is a Tested Pile Repair generally consists of adding a new pile Drilled Shafts Defects may occur during construction Damage after construction is possible but rare Defects are not easily quantified Repair is generally very complex PDPI
26 Driven Pile Damage Handling Fix replace with new pile
27 Driving Driven Pile Damage Pipe pile toe damaged when trying to penetrate limestone identified during installation via dynamic testing Fix spud through caprock, switch hammers PDPI Crack in PSC pile between mudline and water surface identified during installation via dynamic testing Fix underwater patching w epoxy grout, switch hammers
28 Post-Installation Driven Pile Damage 3 to 15 ft Pipe group damaged due to ground movement confirmed via low strain dynamic testing Fix drive H-piles in between broken piles
29 Low Strain Integrity Testing
30 Sample PIT Data PIT Record from a 98-ft long production pile stored on-site (supported on blocks) in/s 3: # 1 MA: 1.00 MD: LE: WS: LO: 0.07 HI: 0.00 PV: 18 T1: 30 T ft Toe Vel in/s 3: # 53 MA: 1.00 MD: LE: WS: LO: 0.00 HI: 0.00 PV: 0 T1: 21 T Toe Vel ft PIT Record from a pile laying on the ground with a break at 46 ft.
31 Records from Broken Pile Group Break If unbroken, no velocity increase before 98 ft, which is the pile toe location
32 Drilled Shaft Defects Slide from Dr. Dan Brown
33 Crosshole Sonic Logging E=ρV 2 F c Constant * E 2
34 Defect or Anomaly Drilled Shaft Case History DOT Project 4.5 ft diameter, 28 ft long shaft (approx 16 cy vol) Dry Method (but Wet) No problems reported on construction logs PDPI
35 Delayed velocity and low energy
36 Good Bad Worse Defect: Segregation caused by free-fall placement of concrete through 10 ft of water (as noted by inspector)
37 Defect or Anomaly Low Energy/Loss of Signal
38 Anomaly: Minor segregation/channelization due to bleed water inconsequential with respect to shaft performance
39 Detectable by CSL?
40 Integrity & Reliablity Summary Pile problems easily identified via testing Repair generally possibly via replacement/supplementation Shaft problems often hard to quantify Remedy of shaft problems may be very difficult PDPI
41 Vibration Misconception Construction Activities generate vibrations Pile driving often inappropriately penalized because of its consistent auditory alert Structures and soil are much more tolerant of vibrations than people
42 Vibration Criteria Slide from Ed Hajduk PDPI Upper blue line is most commonly used
43 Peak Vertical Particle Velocity, in./sec PDPI Peak Vertical Particle Velocity, mm/s 10 Human Perception Thresholds Formation of hairline cracks in plaster and drywall joints 1 Very Disturbing Strongly Perceptible/ Disturbing Approx PPV that will induce 0.01% strain in a very loose sand (Vs of 500 fps) 0.1 Perceptible
44 Oriard s and NAVFAC Criteria (from Oriard, 1999) (from NAVFAC DM-7, 1986)
45 Largest Vibration-Related Claims in Charleston, SC St. Philips Church: Extraction of drilled shaft temporary casing with vibratory hammer French Huguenot Church: Pavement demolition with large track-hoe
46 Driven Piles vs Drilled Shaft Foundation Selection Case Histories PDPI
47 Indian Inlet River Replacement Bridge Design Build Existing Bridge Replacement Bridge Scour concerns no foundations in inlet Larger main pier footings = longer span length (expensive) Two DB teams: winning team used all driven piles, other team used drilled shafts
48 Indian Inlet River Cont. Skanska: voided 36 sq. PSC piles Self-performed Higher resistance factor Faster Less expensive PDPI
49 Main Piers
50 Boeing 787 Second Assembly Line PDPI
51 MAIN BUILDING Eave Height = Continuous Truss 460 Clear Span 16 Thick Floor Slab Utility Tunnel Foundation Alternates in Bid Documents 24 Pipe Piles - 2, 3, 4 and 5 pile groups HP 14 x73 2, 4, 5, and 7 pile groups PDPI Lowest Cost Foundation 4 & 5 dia. Drilled Shafts compressive load 2300 kips uplift 547 kips lateral load 350 kips
52 SC 802 Bridge over Broad Creek Beaufort, SC New bridge adjacent to existing bridge (c. 80s) Existing bridge on driven H-Piles and PSC piles New bridge design requirements Much larger seismic hazard New bridge foundations Driven PSC piles on approaches Drilled shafts at higher bents PDPI
53 Existing Bridge PDPI June 22, 2011 Logan, UT
54 Existing Bridge PDPI June 22, 2011 Logan, UT
55
56
57
58
59
60
61
62
63
64 Power Plant Expansion Major expansion of existing power plant All original structure supported on 3 or 4 diameter drilled shafts (due to karst concern)
65 June 22, 2011 Logan, UT Units 3 & & 2009 $1.4 billion Unit Unit
66 June 22, 2011 Logan, UT Sample Profile
67 June 22, 2011 Logan, UT Sample Profile
68 Coring Comparison Previous Methods Triple-Tube Coring
69 June 26, 2013 Logan, U Coring Comparison Cont. Previous Methods Triple-Tube Coring
70 Foundation Design Part 1 3 or 4 Diameter Drilled Shafts Rock Sockets: fs=12ksf 300 ton Design Load PDPI
71 Drilled Shaft Lateral Response Moment Shear Loose Sand/Soft Clay Santee Limestone
72 Change Since Units 1 & 2 Design New Design Event in Building Code Prior Codes: 10% prob of exceedance in 50 yrs IBC: 2% prob of exceedance in 50 yrs (w 2/3 factor) PDPI
73 Sa (g) PDPI Seismic Hazard Differences Pineville Response Spectra /3 of 2% Probability Event % Probability Event Period (sec)
74 Foundation Alternatives Larger Shafts Ground Improvement Driven Piles Flexible Reduced Liquefaction Potential PDPI
75 Driven Pile Model F internal F Inertial from superstructure Mat Displacement Piles: Mat moves with soil Reduced Liquefaction Reduce LQ Potential due to Densification Santee Limestone
76 Foundation Design Part 2 Driven Piles Bearing on the Santee Limestone 14-in. square PSC Piles: 100 Ton Design Load 12-in. square PSC Piles: 70 Ton Design Load Savings of $6 to $8 million on Unit 3 Savings of 1 to 2 months on Unit 3
77 Construction 20,000+ PSC piles driven 30 piles per rig per day PSC Pile Manufacturers: Tekna & Palmetto Pile Driving Foundation Costs > $100 million
78 June 22, 2011 Logan, UT
79 June 22, 2011 Logan, UT
80 June 22, 2011 Logan, UT
81 Summary Driven Piles Simplicity Cost Reliability Drilled Shafts Capacity Geologic Versatility PDPI
82 Thanks for Listening???? Billy Camp, PE, D.GE Technical Principal/Vice President S&ME, Inc. Charleston, SC
Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation
Micropiles Reduce Costs and Schedule for Merchant RR Bridge Rehabilitation Jeff R. Hill, P.E. Hayward Baker Inc. 111 W. Port Plaza Drive Suite 600 St. Louis, MO 63146 314-542-3040 [email protected]
High Strain Dynamic Load Testing of Drilled Shafts
Supplemental Technical Specification for High Strain Dynamic Load Testing of Drilled Shafts SCDOT Designation: SC-M-712 (9/15) September 3, 2015 1.0 GENERAL This work shall consist of performing high-strain
SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS
July 14, 2015 1.0 GENERAL BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS This work shall consist of furnishing all materials, equipment, labor, and incidentals necessary for conducting bi-directional
Design and Construction of Auger Cast Piles
Design and Construction of Auger Cast Piles 101 th Annual Road School 2015 3/11/2015 Malek Smadi, Ph.D., P.E. Principal Engineer - GEOTILL - Fishers, IN [email protected] - www.geotill.com CONTENTS 1.
SAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DEEP FOUNDATIONS
Page 1 of 9 SAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DEEP FOUNDATIONS 1. GENERAL REQUIREMENTS 1. Description of Work: This work consists of furnishing all materials, equipment and
SECTION 411 DRILLED PIERS
Section Payment will be made under: Pay Item Foundation Excavation Foundation Excavation for Bent No. at Station Foundation Excavation for End Bent No. at Station Pay Unit Cubic Yard Lump Sum Lump Sum
STRUCTURES. 1.1. Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.
STRUCTURES 1. General. Critical structures may impact the integrity of a flood control project in several manners such as the excavation for construction of the structure, the type of foundation, backfill
BUTE Department of Construction Management and Technology
BUTE Department of Construction Management and Technology 02.10.2012 Definition 1: Foundation: The structure, that transmits the load of the building to the soil Definition 2: Load bearing soil (strata):
ITEM #0702770 OSTERBERG CELL LOAD TESTING OF DRILLED SHAFT
ITEM #0702770 OSTERBERG CELL LOAD TESTING OF DRILLED SHAFT Description: This work shall consist of furnishing all materials, equipment and labor necessary for conducting an Osterberg Cell (O-Cell) Load
GLOSSARY OF TERMINOLOGY
GLOSSARY OF TERMINOLOGY AUTHORIZED PILE LENGTHS - (a.k.a. Authorized Pile Lengths letter) Official letter stating Engineer's recommended length of concrete piles to be cast for construction of foundation.
Design, Testing and Automated Monitoring of ACIP Piles in Residual Soils
Design, Testing and Automated Monitoring of ACIP Piles in Residual Soils Stephen W. Lacz 1, M. ASCE, P.E. and Richard C. Wells 2, F. ASCE, P.E. 1 Senior Professional, Trigon Kleinfelder, Inc., 313 Gallimore
CHAPTER 9 LONG TERM MONITORING AT THE ROUTE 351 BRIDGE
CHAPTER 9 LONG TERM MONITORING AT THE ROUTE 351 BRIDGE 9.1 INTRODUCTION An important reason that composite piles have not gained wide acceptance in the civil engineering practice is the lack of a long
Table of Contents 16.1 GENERAL... 16.1-1. 16.1.1 Overview... 16.1-1 16.1.2 Responsibilities... 16.1-1
Table of Contents Section Page 16.1 GENERAL... 16.1-1 16.1.1 Overview... 16.1-1 16.1.2 Responsibilities... 16.1-1 16.1.2.1 Geotechnical Section/Bridge Bureau Coordination... 16.1-1 16.1.2.2 Geotechnical
High Capacity Helical Piles Limited Access Projects
High Capacity Helical Piles Limited Access Projects Tel 403 228-1767 Canada, USA, Russia Brendan ODonoghue 519 830-6113 Presentation Summary 1. Helical piles Background on large diameter shafts and helices
USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch
USE OF MICROPILES IN TEXAS BRIDGES by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch DEFINITION OF A MICROPILE A micropile is a small diameter (typically less than 12 in.), drilled and
SECTION 1 GENERAL REQUIREMENTS
Page 1 of 6 SECTION 1 GENERAL REQUIREMENTS 1. SCOPE OF WORK: The work to be performed under the provisions of these documents and the contract based thereon includes furnishing all labor, equipment, materials,
Settlement & Vibration Monitoring for Transmission Line Foundation Installation
Settlement & Vibration Monitoring for Transmission Line Foundation Installation R. Heath Forbes, P.E. S&ME, Inc. William M. Camp, III, P.E. S&ME, Inc. Presented By: Heath Forbes, P.E. Project Engineer
New construction Repairing failed or old foundations Retrofit foundations Permanent battered piers Machinery/equipment foundations
from New construction foundations don t have to be a headache. The CHANCE Helical Pier Foundation System gives you the performance of concrete without the drawbacks and liabilities of driven piles and
Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. The Leading Edge.
TM TM Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. SM The Leading Edge. 10 One Major Causes of foundation settlement or more conditions may
TYPES OF PIERS USED IN NORTH AND EAST TEXAS RESIDENTIAL FOUNDATION REPAIR
TYPES OF PIERS USED IN NORTH AND EAST TEXAS RESIDENTIAL FOUNDATION REPAIR If you listen to the hype, it sounds like there must be 20 or 30 different types of piers out there. Company A says they have an
Load Testing of Drilled Shaft Foundations in Limestone, Nashville, TN Dan Brown, P.E., Ph.D.
Dan A. Brown and Associates Consulting Geotechnical Engineers 300 Woodland Rd. (423)942-8681 Sequatchie, TN 37374 fax:(423)942-8687 Load Testing of Drilled Shaft Foundations in Limestone, Nashville, TN
Emergency repair of Bridge B421
Emergency repair of Bridge B421 over the Olifants River after fl ood damage INTRODUCTION AND BACKGROUND Bridge B421 is located on the R555 at km 5.03 on Section 01E between Witbank (now known as emalahleni)
MEMORANDUM. 1509 West Swann Avenue, Suite 225 Tampa, Florida 33606 Phone (813) 258-8818 Fax (813) 258-8525
1509 West Swann Avenue, Suite 225 Tampa, Florida 33606 Phone (813) 258-8818 Fax (813) 258-8525 To: From: Date: Subject: Mr. Thomas Gibson, City of St. Petersburg Jeffrey D. Malyszek, PE and Deborah C.
ENGINEERED FOUNDATIONS. Department of Public Works Jeff Hill, PE
ENGINEERED FOUNDATIONS Department of Public Works Jeff Hill, PE What is an engineered foundation. A Foundation Design Developed by a Trained Professional (Engineer) Types of Foundations (All of which can
Structural Failures Cost Lives and Time
Structural Failures Cost Lives and Time Recent failures of storage bins, silos and other structures highlight the need to increase awareness of hazards associated with these structures. Since 2010, one
METHOD OF STATEMENT FOR STATIC LOADING TEST
Compression Test, METHOD OF STATEMENT FOR STATIC LOADING TEST Tension Test and Lateral Test According to the American Standards ASTM D1143 07, ASTM D3689 07, ASTM D3966 07 and Euro Codes EC7 Table of Contents
vulcanhammer.net This document downloaded from
This document downloaded from vulcanhammer.net since 1997, your source for engineering information for the deep foundation and marine construction industries, and the historical site for Vulcan Iron Works
Geotechnical Building Works (GBW) Submission Requirements
Building Control (Amendment) Act 2012 and Regulations 2012: Geotechnical Building Works (GBW) Submission Requirements Building Engineering Group Building and Construction Authority May 2015 Content : 1.
Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing
1 Most basements show some signs of leaking and cracking. Through the years, problems with water, poor soils, grading, drainage and possible settling affect the integrity of a basement. Being able to recognize
The unit costs are based on the trend line of the 3 low bids for the average quantity.
Page 1 of 8 COST ESTIMATE GENERAL INSTRUCTIONS The unit costs are based on the trend line of the 3 low bids for the average quantity. Apply the Unit Costs to ordinary structures. Unit Costs should generally
1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona
for Earthen Material and Straw Bale Structures SECTION 70 - GENERAL "APPENDIX CHAPTER 7 - EARTHEN MATERIAL STRUCTURES 70. Purpose. The purpose of this chapter is to establish minimum standards of safety
How to Design and Build a Fence/G traverse Bridge or Graffiti Project
Outline Project Location Project Description Project History Site Constraints Geotechnical Investigation & Soil Profile Foundation Design Process Photos Project Location Project Limits: The Grand River
2010-2011 Contractor of the Year
U.S. Army Corps of Engineers: Little Calumet River Stage VII Steel Sheet Piling Installation Hammond, Indiana Thatcher worked two rigs concurrently one on the north side and one on the south. The United
Measuring the Condition of Prestressed Concrete Cylinder Pipe
Measuring the Condition of Prestressed Concrete Cylinder Pipe John Marshall, P.E.I, I J.W. Marshall and Associates, and Paul S. Fisk, President NDT Corporation Introduction Prestressed Concrete Cylinder
ATLAS RESISTANCE Pier Foundation Systems
ATLAS RESISTANCE Pier Foundation Systems Foundation Repair Systems for Civil Construction Applications: Residential, Commercial, Industrial Atlas Resistance Piers have been used to restore and/or stabilize
COSMOS 2012: Earthquakes in Action COSMOS 2012
COSMOS 2012 What is SFSI and why is it important? Soil issues in Earthquakes Structures where SFSI important Retaining structures (lateral earth pressure) Foundations (spread and pile footings, bearing
1,045 m length of the Deh Cho Bridge
Innovative Design Features: Lightweight truss: The principles of lightweight design led to a saving of 25% in the use of structural steel. State of the art deck system: Designed as a four-way slab, it
Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training
Foundations 65 5 FOUNDATIONS by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. 66 Foundations Foundations 67 FOUNDATIONS Let's assume that the retrofit has been done correctly from the roofline
BRIDGE RESTORATION AND LANDSLIDE CORRECTION USING STRUCTURAL PIER AND GRADE BEAM
BRIDGE RESTORATION AND LANDSLIDE CORRECTION USING STRUCTURAL PIER AND GRADE BEAM Swaminathan Srinivasan, P.E., M.ASCE H.C. Nutting/Terracon David Tomley, P.E., M.ASCE KZF Design Delivering Success for
June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL
7.0 7.1 GENERAL For the purpose of this manual, culverts are defined as structures that are completely surrounded by soil and located below the surface of the roadway parallel to the general direction
Structures Construction Pre-Work Checklist PRE-WORK SHEET FOR PROJECT MANAGERS
Structures Construction Pre-Work Checklist PRE-WORK SHEET FOR PROJECT MANAGERS 1 Proposal & Plans Received? 2 Review Proposal, highlight important facts. Know proposal well to be able to find answers quickly.
The Installation and Load Testing of Drilled Shafts
Presentation to the North American Chinese Geotechnical Engineers Association The Installation and Load Testing of Drilled Shafts at Clarksville, Virginia by James M. Sheahan, P.E. HDR Engineering, Inc.
Safe & Sound Bridge Terminology
Safe & Sound Bridge Terminology Abutment A retaining wall supporting the ends of a bridge, and, in general, retaining or supporting the approach embankment. Approach The part of the bridge that carries
How to Estimate the Cost of Support of Excavation for Foundation Installation. CPE Candidate No. 0113013. May 15, 2013
How to Estimate the Cost of Support of Excavation for Foundation Installation CPE Candidate No. 0113013 May 15, 2013 1 How to Estimate the Cost of Support of Excavation for Foundation Installation Table
Chapter. Restoration of Damaged Structures
5 Chapter Restoration of Damaged Structures Bringing back a damaged structure to its pre-earthquake state and original strength is called restoration. This is the first step of building rehabilitation.
6 RETROFITTING POST & PIER HOUSES
Retrofitting Post & Pier Houses 71 6 RETROFITTING POST & PIER HOUSES by James E. Russell, P.E. 72 Retrofitting Post & Pier Houses Retrofitting Post & Pier Houses 73 RETROFITTING POST AND PIER HOUSES This
Outline MICROPILES SUBJECT TO LATERAL LOADING. Dr. Jesús Gómez, P.E.
MICROPILES SUBJECT TO LATERAL LOADING Dr. Jesús Gómez, P.E. Micropile Design and Construction Seminar Las Vegas, NV April 3-4, 2008 Outline When are micropiles subject to lateral load? How do we analyze
Now That s IDEAL. Now That s IDEAL. LISTEN. RESEARCH. DESIGN. DELIVER.
The Leading Edge SM At IDEAL, we try not to complicate things. We discover needs and problems, then work out solutions. It takes real teamwork to accomplish truly great things. That s you and us, working
CID STREET INFRASTRUCTURE ASSESSMENT
ABSTRACT An evaluation of the street infrastructure in Foxberry Estates Phase 1, including pavement condition, verification of construction techniques, and subgrade quality. Recommendations and costs for
PILE FOUNDATIONS FM 5-134
C H A P T E R 6 PILE FOUNDATIONS Section I. GROUP BEHAVIOR 6-1. Group action. Piles are most effective when combined in groups or clusters. Combining piles in a group complicates analysis since the characteristics
Paving Capitalization Work Categories and Treatments
Statement of ODOT Infrastructure Capitalization Policy Government Accounting Standards Board (GASB) 34 requires public agencies to capitalize infrastructure assets on their financial statements for periods
Federation of Piling Specialists Testing Datasheet No 1
Testing Datasheet No 1 Guidance for the Principal Contractor It is an essential requirement that the specialist testing contractor is allowed to work in a safe way and fully in accordance with their own
Dr. Jesús Gómez, P.E. 36th Annual Conference on Deep Foundations, Boston, MA
FHWA Hollow Bar Soil Nail (HBSN) Test Program Dr. Jesús Gómez, P.E. 36th Annual Conference on Deep Foundations, Boston, MA Outline Introduction and motivation Installation methods for testing Testing and
California Department of Transportation Doyle Drive Test Program Contract No. 04A3362
California Department of Transportation Doyle Drive Test Program Deep Soil Mixing (DSM) /Cutter Soil Mixing (CSM) Testing Report By Malcolm Drilling Company, Inc. 3524 Breakwater Ave., Suite 108 Hayward,
SHAFT CONSTRUCTION IN TORONTO USING SLURRY WALLS
SHAFT CONSTRUCTION IN TORONTO USING SLURRY WALLS Vince Luongo Petrifond Foundation Co., Ltd. PROJECT DESCRIPTION The York Durham Sanitary System (YDSS) Interceptor in the Town of Richmond Hill located
Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE
Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE To satisfy the performance goals of the NEHRP Recommended Seismic Provisions, a number of characteristics are important to the
INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!
In-situ Testing! Insitu Testing! Insitu testing is used for two reasons:! To allow the determination of shear strength or penetration resistance or permeability of soils that would be difficult or impossible
CERTIFIED TECHNICIAN PROGRAM TRAINING MANUAL. Bridge Construction and Deck Repair
CERTIFIED TECHNICIAN PROGRAM TRAINING MANUAL Bridge Construction and Deck Repair Revised 2014 This material is to be used for training purposes only. Some of the procedures, field tests, and other operating
2006-2008 MHD BRIDGE SECTION WEIGHTED AVERAGE UNIT PRICES GUIDELINES FOR THE USE OF THE WEIGHTED AVERAGE UNIT PRICE TABULATION SHEETS
2006-2008 MHD BRIDGE SECTION WEIGHTED AVERAGE UNIT PRICES GUIDELINES FOR THE USE OF THE WEIGHTED AVERAGE UNIT PRICE TABULATION SHEETS GENERAL 10/16/2008 The listed average unit prices are based on the
Geotechnical Investigation Reports and Foundation Recommendations - Scope for Improvement - Examples
Geotechnical Investigation Reports and Foundation Recommendations - Scope for Improvement - Examples Prof. V.S.Raju (Formerly: Director, IIT Delhi & Professor and Dean, IIT Madras) Email: [email protected]
EXAMPLE 1 DESIGN OF CANTILEVERED WALL, GRANULAR SOIL
EXAMPLE DESIGN OF CANTILEVERED WALL, GRANULAR SOIL A sheet pile wall is required to support a 2 excavation. The soil is uniform as shown in the figure. To take into account the friction between the wall
UNDERPINNING OF NEW STUDENT HOUSING BUILDING USING MICROPILES, NORTH CAROLINA USA
UNDERPINNING OF NEW STUDENT HOUSING BUILDING USING MICROPILES, NORTH CAROLINA USA John R. Wolosick, P.E.,D.GE 1, Michael W. Terry, P.E. 2, W. David Kirschner 3 and Robert F. Scott Jr. P.E. 4 SYNOPSIS In
Local Authority Building Control Technical Information Note 3 Driven and In-situ Piled Foundations
Local Authority Building Control Technical Information Note 3 Driven and In-situ Piled Foundations Cambridge City Council - East Cambridgeshire District Council - Fenland District Council, Huntingdonshire
Comprehensive Design Example 2: Foundations for Bulk Storage Facility
Comprehensive Design Example 2: Foundations for Bulk Storage Facility Problem The project consists of building several dry product storage silos near an existing rail siding in an open field presently
FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples
FOUNDATION DESIGN Proportioning elements for: Transfer of seismic forces Strength and stiffness Shallow and deep foundations Elastic and plastic analysis Foundation Design 14-1 Load Path and Transfer to
High-Speed Nondestructive Testing and Intelligent Construction Systems
High-Speed Nondestructive Testing and Intelligent Construction Systems 1st International Conference on Transportation Construction Management February 9-11, 9 2008 Orlando, Florida Ted Ferragut, P.E. NDT
BRIDGES ARE relatively expensive but often are
Chapter 10 Bridges Chapter 10 Bridges Bridg Bridges -- usually the best, but most expensive drainage crossing structure. Protect bridges against scour. BRIDGES ARE relatively expensive but often are the
POST FOUNDATION REPAIR PERFORMANCE RESIDENTIAL AND OTHER LOW-RISE BUILDINGS ON EXPANSIVE SOILS. The Repair Committee of
Issued for Website Publishing Foundation Performance Association - Repair Committee Page 1 of 10 POST FOUNDATION REPAIR PERFORMANCE OF RESIDENTIAL AND OTHER LOW-RISE BUILDINGS ON EXPANSIVE SOILS by The
GEORGE J. CAMBOURAKIS, P.E., C. ENG. PRESIDENT & CHIEF STRUCTURAL ENGINEER
GEORGE J. CAMBOURAKIS, P.E., C. ENG. PRESIDENT & CHIEF STRUCTURAL ENGINEER Professional Experience: Pride and Passion in the Art of Structural Engineering since 1979. Professional Registration: Professional
Kentucky Lake Bridge Pile Load Testing Overview Ohio Transportation Engineering Conference Columbus, Ohio 10/28/2015
Kentucky Lake Bridge Pile Load Testing Overview Ohio Transportation Engineering Conference Columbus, Ohio 10/28/2015 Presented by: Jeff Dunlap, P.E. Terracon Consultants 1 Project Site Kentucky Official
IH-635 MANAGED LANES PROJECT, SEG. 3.2
IH-635 MANAGED LANES PROJECT, SEG. 3.2 Location: Dallas, Texas Owner: Texas Department of Transportation Client: Ferrovial Agroman Construction Cost: $1 Billion Construction Completion Date: December,
National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination
Structural Effective Beginning with the April 2011 The structural engineering exam is a breadth and exam examination offered in two components on successive days. The 8-hour Vertical Forces (Gravity/Other)
Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations
Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations Nathan A. Ingraffea, P.E., S.E. Associate, KPFF Consulting Engineers, Portland, Oregon, USA Abstract The use of steel sheet
C. Section 014510 TESTING LABORATORY SERVICE.
SECTION 014500 QUALITY CONTROL PART 1 GENERAL 1.01 RELATED REQUIREMENTS A. Drawings and General Provisions of Contract, including General and Special Conditions and other Division 1 Specification Sections,
Dynamic Load Testing of Helical Piles
Dynamic Load Testing of Helical Piles ANNUAL KANSAS CITY SPECIALTY SEMINAR 2014 JANUARY 10, 2014 Jorge Beim JWB Consulting LLC Pile Dynamics, Inc. Main Topics Brief description of the Dynamic Load Test
The International Workshop on Micropiles, 2007
MICROPILE FOUNDATION REPAIR AND UNDERPINNING, ARTS AND SCIENCE MUSEUM, UNIVERSITY OF PUERTO RICO, MAYAGUEZ Presented at: International Society of Micropiles (ISM) The International Workshop on Micropiles,
PDCA Driven-Pile Terms and Definitions
PDCA Driven-Pile Terms and Definitions This document is available for free download at piledrivers.org. Preferred terms are descriptively defined. Potentially synonymous (but not preferred) terms are identified
Important Points: Timing: Timing Evaluation Methodology Example Immediate First announcement of building damage
3.3. Evaluation of Building Foundation Damage Basic Terminology: Damage: Destruction, deformation, inclination and settlement of a building foundation caused by an earthquake. Damage grade: Degree of danger
INSTALLATION SPECIFICATION FOR DRIVEN PILES
INSTALLATION SPECIFICATION FOR DRIVEN PILES PDCA 103-07 PDCA Approved August 2007 PDCA Technical Committee Pile Driving Contractors Association www.piledrivers.org [email protected] 2007, Pile Driving
LEADSYSTEMS. Vertical Configuration. Aft Batter Below Grade. Side Batter. Forward Reach. Raised Leads Above Grade. Forward Batter
LEADSYSTEMS Vertical Configuration Aft Batter Below Grade Side Batter Forward Reach Raised Leads Above Grade Forward Batter LEAD SYSTEM Located in Hamilton, Ontario, Canada, Bermingham Foundation Solutions
2015 ODOT Bridge Design Conference May 12, 2014. DeJong Rd Bridge High- Seismic Zone Case Study: Bridge Rehab vs. Replacement.
2015 ODOT Bridge Design Conference May 12, 2014 DeJong Rd Bridge High- Seismic Zone Case Study: Bridge Rehab vs. Replacement Mary Ann Triska 2015 HDR, all rights reserved. Presentation Outline Project
Comparison of Seismic Retrofitting Methods for Existing Foundations in Seismological Active Regions
Comparison of Seismic Retrofitting Methods for Existing Foundations in Seismological Active Regions Peyman Amini Motlagh, Ali Pak Abstract Seismic retrofitting of important structures is essential in seismological
Disputes and Claims. 3 Processes Dispute Resolution and Administrative Claims Process
Disputes and Claims 3 Processes Dispute Resolution and Administrative Claims Process Default Process C&MS 108.02 Partnering OR PN 108 -Dispute Review Board (DRB) Considered for use on projects over $20
SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT
SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT 1.0 SOIL IMPROVEMENT 1.1 General Soil Investigation Information are provided in Part B1 annex as a guide to the Contractor for his consideration
US 51 Ohio River Bridge Engineering and Environmental Study
US 51 Ohio River Bridge Engineering and Environmental Study ITEM NOS. 1-100.00 & 1-1140.00 Prepared by: Michael Baker Jr., Inc. 9750 Ormsby Station Rd Louisville, KY 40223 August 16, 2013 Table of Contents
Designed and Engineered to Perform
History EARTH CONTACT PRODUCTS, L.L.C., is a family owned company, based in Olathe, Kansas. This company was built upon Don May s U.S. Patented fourth-generation Steel Piering System that has led to the
Moving Small Mountains Vesuvius Dam Rehab
Moving Small Mountains Vesuvius Dam Rehab Susan L. Peterson, P.E., regional dams engineer, Eastern Region, Bedford, IN Note: The following article, Moving Small Mountains Vesuvius Dam Rehab, by Sue Peterson,
Federation of Piling Specialists July 2010
Examples of Hazards associated with Piling and Diaphragm Walling Works and how these might be managed within the design phase of a project (neither exhaustive nor exclusive) This list of examples has been
Durability, Versatility
Precast Concrete Piles Provide Durability, Versatility Precast, prestressed piles offer a range of advantages, particularly in corrosive environments, but proper installation is the key to maximizing the
Bridge Structural Rehabilitation Using FRP Laminates
Bridge Structural Rehabilitation Using FRP Laminates South Santiam River Quartzville Road, Linn County Linn County Road Department 2011 Cooperative Partnerships Making Linn County a Better Place to Live
Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps
Foundations on Expansive Clay Soil Part 3 - Investigation of Failed Foundations Presented by: Eric Green, P.E. Structural Engineer Slide 1 Copyright Eric Green 2005 Investigation of Foundation Failure
System. Stability. Security. Integrity. 150 Helical Anchor
Model 150 HELICAL ANCHOR System PN #MBHAT Stability. Security. Integrity. 150 Helical Anchor System About Foundation Supportworks is a network of the most experienced and knowledgeable foundation repair
-SQA-SCOTTISH QUALIFICATIONS AUTHORITY HIGHER NATIONAL UNIT SPECIFICATION GENERAL INFORMATION
-SQA-SCOTTISH QUALIFICATIONS AUTHORITY HIGHER NATIONAL UNIT SPECIFICATION GENERAL INFORMATION -Unit number- 4420798 -Unit title- CONSTRUCTION TECHNOLOGY 2: SUBSTRUCTURE AND REMEDIAL WORKS -Superclass category-
DUDERSTADT FOUNDATION & CONSTRUCTION, LLC.
DUDERSTADT FOUNDATION & CONSTRUCTION, LLC. Drilling since 1916 2215 Belknap Place Phone (210) 824-3800 San Antonio, TX 78212-1904 Fax (210) 824-9525 www.duderstadtfoundation.com ABOUT THE COVER: Drilled
Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries
Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries Introduction Wastewater of petrochemical industries and refineries contains high amounts of emulsified aliphatic or
MICROPILE FOUNDATIONS IN KARST: STATIC AND DYNAMIC TESTING VARIABILITY
MICROPILE FOUNDATIONS IN KARST: STATIC AND DYNAMIC TESTING VARIABILITY Jesús Gómez, Ph.D., P.E Allen Cadden, P.E. O. Christopher Webster, P.E. Schnabel Engineering, Inc. Schnabel Engineering, Inc. Schnabel
DESIGNING STRUCTURES IN EXPANSIVE CLAY
DESIGNING STRUCTURES IN EXPANSIVE CLAY A GUIDE FOR A RCHITECTS AND E NGINEERS Table of Contents 1. Introduction Page 1 2. Common Foundation Systems Page 2 3. Drilled Piers Page 3 a. Skin Friction Piers
APPENDIX G SETTLEMENT
APPENDIX G SETTLEMENT TABLE OF CONTENTS G.1 IN T R O D U C T IO N... 1 G.2 MATERIAL PLACEMENT AND COMPACTION... 1 G.2.1 Incom pressible M aterials... 1 G.2.2 Compressible Materials... 2 G.2.3 Soil P lacem
Pro-Lift Steel Pile Foundation Repair
Pro-Lift Steel Pile Foundation Repair Pro-Lift Steel Pile Foundation Repair System Pro-lift steel piles are designed for the stresses of Texas soils. They can have multiple steel walls, depending on the