MultiModem. AT Commands Reference Guide
|
|
|
- Anne Wilson
- 9 years ago
- Views:
Transcription
1 MultiModem For MultiModem ZBA Series MultiModem IND MultiModem DID MultiModem ZPX Series MultiModem ZPX-ISA MultiModem ISI Series AT Commands Reference Guide
2 Copyright and Technical Support AT Commands Reference Guide The Following Products Use This Command Set: External Modems: MultiModem ZBA (MT5634ZBA Series, MT5634ZBA-USB, MT5634IND, MT5634ZBA-DID) Internal Modems: MultiModem ZPX (MT5634ZPX-PCI Series, MT5634ZPX-ISA) Server Cards: MultiModem ISI (SI5634UPCI Series) Legacy Modems: MultiModem (MT5634ZLX Series) PN S000272J, Version J Copyright This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi- Tech Systems, Inc. All rights reserved. Copyright , by Multi-Tech Systems, Inc. Multi-Tech Systems, Inc. makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes. Revisions Revision Level Date Description A 10/30/02 Initial release. B 02/24/03 Change +PIG=0 to enable PCM upstream with default 1. Add #CBS4. Add +VRID. C 10/01/03 The guide is now applicable to the ISI5634PCI. D 11/17/03 This guide is now applicable to the MT5634ZPX-ISA. Explained the default for the S-Register S0: the default for internal modems is 0 while the default external modems is 1. E 01/04/05 Removed \X command. Added &L for the MT5634IND. Added Index crossreferences. Changed font. F 12/30/05 Changed the description of \N1. Added a chapter on setting country codes. G 04/11/07 Updated the Technical Support contact list. H 12/28/07 Changed Technical Support contact list. I 02/05/10 Updated the $FC command. J 09/02/10 Updated Chapter 4, Setting Your Country/Regional Code. Added the default (0) to &L, Leased-Line Operation. Added a note and example to S-Registers regarding Range and Default as dependent upon country code. Added examples of S-Register ranges and defaults as determined by country codes. 10/07/10 Updated the Multi-Tech web link to the global configuration page. Trademarks MultiModem and the Multi-Tech logo are Registered Trademarks of Multi-Tech Systems, Inc. World Headquarters Multi-Tech Systems, Inc Woodale Drive Mounds View, Minnesota Phone: or Fax: Internet Address: Technical Support Please the Copyright/Technical Support page of the product User Guide or Developer Guide. Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 2
3 Contents Contents Chapter 1 - AT Commands... 4 Introduction... 4 List of General Commands... 5 List of V.92 Commands... 6 List of Caller ID Commands... 6 List of Callback Commands... 6 List of Escape Commands... 7 List of DID Commands... 7 AT Commands Detail... 8 V.92 Commands Caller ID Commands Callback Security Commands Escape Sequence Commands DID Commands Chapter 2 - S-Registers Examples of Ranges and Defaults Determined by Country Codes Chapter 3 - Result Codes Chapter 4 Setting Your Country or Regional Code Index Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 3
4 Introduction Chapter 1 - AT Commands The AT commands are used to control the operation of your modem. They are called AT commands because the characters AT must precede each command to get the ATtention of the modem. AT commands can be issued only when the modem is in command mode or online command mode. The modem is in command mode whenever it is not connected to another modem. The modem is in data mode whenever it is connected to another modem and ready to exchange data. Online command mode is a temporary state in which you can issue commands to the modem while connected to another modem. To put the modem into online command mode from data mode, you must issue an escape sequence (+++) followed immediately by the AT characters and the command, e.g., +++ to hang up the modem. To return to data mode from online command mode, you must issue the command ATO. To send AT commands to the modem you must use a communications program, such as the HyperTerminal applet in Windows 98/95 and NT 4.0, or some other available terminal program. You can issue commands to the modem either directly, by typing them in the terminal window of the communications program, or indirectly, by configuring the operating system or communications program to send the commands automatically. Fortunately, communications programs make daily operation of modems effortless by hiding the commands from the user. Most users, therefore, need to use AT commands only when reconfiguring the modem; e.g., to turn autoanswer on or off. The format for entering an AT command is ATXn, where X is the command and n is the specific value for the command, sometimes called the command parameter. The value is always a number. If the value is zero, you can omit it from the command; thus, AT&W is equivalent to AT&W0. Most commands have a default value, which is the value that is set at the factory. You must press ENTER (depending on the terminal program it could be some other key) to send the command to the modem. Any time the modem receives a command, it sends a response known as a result code. The most common result codes are OK, ERROR, and the CONNECT messages that the modem sends to the computer when it is connecting to another modem. You can issue several commands in one line, in what is called a command string. The command string begins with AT and ends when you press ENTER. Spaces to separate the commands are optional; the command interpreter ignores them. The most familiar command string is the initialization string, which is used to configure the modem when it is turned on or reset, or when your communications software calls another modem. Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 4
5 List of General Commands Command Description AT Attention Code A Answer A/ Repeat Last Command B Communication Standard Setting Bell or CCITT D Dial %M Enable Dialing Message DS=n Dial Stored Telephone Number E Echo Command F Echo Online Data Characters H Disconnect (Hang Up) I Information Request L Not Applicable M Monitor Speaker Mode N Modulation Handshake O Return to Online Data Mode P Set Pulse Dial Default Q Result Codes Enable/Disable Sr=n Set Register Value Sr? Read Register Value T Set Tone Dial Default V Result Code Format W Result Code Options X Result Code Selection Z Modem Reset &C Data Carrier Detect (DCD) Control &D Data Terminal Ready (DTR) Control &E XON/OFF Pacing Control &F Restore Factory Settings (Configuration) &G Select Guard Tone Control &K Flow Control Selection &L Leased-Line Operation &Q Asynchronous Communication Mode (same as \N Error Correction Mode) &S Data Set Ready (DSR) Control &T Loopback Tests &V Display Current Settings (Configuration and Stored Profiles) &W Store Current Settings (Configuration and Stored Profiles) &Zn=x Store Dialing Command \A Select Maximum MNP Block Size \B Transmit Break to Remote \K Break Control \N Error Correction Mode Selection \Q Flow Control Selection \T Inactivity Timer \V Protocol Result Code -C Data Calling Tone %A Adaptive Answer Result Code Enable %B View Numbers in Blacklist %C Data Compression Enable/Disable %DC AT Command Control %DT AT Command Timer %E Fallback and Fall Forward Control %H Direct Connect Enable %R Cisco Configuration %S Response Speed $D DTR Dialing $EB Asynchronous Word Length $LB Long Break $RP Response Priority $SB Serial Port Baud Rate Chapter 1 AT Commands Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 5
6 List of V.92 Commands Command Description +PCW=n Call Waiting Enable +PIG=n PCM Upstream Enable +PMH=n Modem-on-Hold Enable +PMHF V.92 Modem Hook Flash +PMHR=n Modem-on-Hold Initiate +PMHTR=n Modem-on-Hold Timer +PQC=n Quick Connect Control +DCS=x,y Select V.44 Data Compression +DR=n V.44 Data Compression Reporting +DS44=n V.44 Data Compression +MS Modulation Selection $FC Quick Connect List of Caller ID Commands Command Description +VCID Caller ID Enable/Disable +VDR=x,y Distinctive Ring Report ERROR +VRID Allows query of modem s last call received List of Callback Commands These commands are used with modems that support Callback Security Command Description #CBA Callback Attempts #CBD Callback Delay #CBF? Callback Failed Attempts Display #CBFR Callback Failed Attempts Reset #CBI Local Callback Inactivity Timer #CBNy=x Store Callback Password #CBP Callback Parity #CBR Callback Security Reset #CBS Callback Enable/Disable #P Set 11-bit Parity #Sx Enter Setup Password #S=x Store Setup Password Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 6
7 List of Escape Commands Command Description +++AT Escape Sequence %%%ATMTSMODEM Remote Configuration Escape Sequence List of DID Commands Command Description *DD Digit Format *DF Format for Reporting Incoming DID Number *DS Start Protocol *DT Wait for Digit Time-Out Time *DW Busy Out After Call Completion *DN Number of DID Digits *DW Busy Out After Call Completion *DN Number of DID Digits Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 7
8 AT Commands Detail Command: AT Attention Code n/a The attention code precedes all command lines except A/ and escape sequences. Command: A Answer n/a Answer an incoming call before the final ring. Command: A/ Repeat Last Command n/a Repeat the last command string. Do not precede this command with AT. Do not press ENTER to execute. Command: Bn Communication Standard Setting n = 0-3, 15, 16 1 and 16 B0 Select ITU-T V.22 mode when modem is at 1200 bps B1 Select Bell 212A when modem is 1200 bps. B2 Deselect V.23 reverse channel (same as B3). B3 Deselect V.23 reverse channel (same as B2). B15 Select V.21 when modem is at 300 bps. B16 Select Bell 103 when modem is at 300 bps. Command: Ds Dial s = dial string (phone number and dial modifiers) none Dial telephone number s, where s may be up to 40 characters long and include these characters: 0-9, *, #, A, B, C, D Can also include these Dial String Modifiers: L, P, T, W, S, comma (,), semicolon ^, and $. Dial String Characters and Modifiers 0-9 DTMF digits 0 to 9. * The 'star' digit (tone dialing only). # The 'gate' digit (tone dialing only). A-D Some countries may prohibit sending of these digits during dialing (tone dialing only) L Redial last number. (Must be placed immediately after ATD.) P Selects pulse dialing until a T is encountered. Affects current and subsequent dialing. Some countries prevent changing dialing modes after the first digit is dialed. T Selects tone dialing until a P is encountered. Affects current and subsequent dialing. Some countries prevent changing dialing modes after the first digit is dialed. W Wait for a new dial tone before continuing to dial. (X2, X4, X5, X6, or X7 must be selected). S=n Dial the number stored in the directory (n = 0 to 3). (See &Z.), Pause during dialing for set set in in register S8. ; Return to command mode after dialing. Place at the end of dial string.! Hook Flash. Causes the modem to go on-hook for a time defined by the value of S29, then off-hook again. Country requirements may limit the time Wait for quiet answer (silence). Causes the modem to wait for a ring back, then 5 seconds of silence before processing the next part of the command. If silence is not detected, the modem returns a NO ANSWER code. ^ Toggles the calling tone between enable/disable. Applicable to current dial attempt only. $ Detect AT&T call card bong tone. The character should follow the phone number and precede the user s call card number: ATDT $ Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 8
9 Ignored Characters ( ) Ignored: may be used to format the dial string. - Ignored: may be used to format the dial string. <space> Ignored: may be used to format the dial string. <i> Invalid character: will be ignored. Command: %M Enable Dialing Message 0, 1 Enables dialing message. It will display when the ATDL=n command is used and dialing from memory or DTR dialing. 0 = Disabled - turns dialing message off 1 = Enabled - turns dialing message on Command: DS=n Dial Stored Telephone Number n = 0, 1, 2 none Dials a number previously stored in the directory by the &Zn=x command. Ex: ATDS=2. Command: En Echo Command n = 0 or 1 1 E0 Disables echo command. E1 Enables echo command. Command: Fn Echo Online Data Characters n = 0, 1 1 F0 Enables online data character echo. (Not supported.) F1 Disables online data character echo (included for backward compatibility). Command: Hn Disconnect (Hang Up) n = 0 or 1 H0 The modem goes on-hook (hangs up). H1 The modem goes off-hook (makes the phone line busy). Command: In Information Request n = 0 5, 9, 11 None I0 Displays default speed and controller firmware version. I1 Calculates and displays ROM checksum (e.g., B399). I2 Checks ROM and verifies the checksum, displaying OK or ERROR. I3 Displays default speed and controller firmware version. I4 Displays firmware version for data pump (e.g., 17).. I5 Displays the board ID: software version, hardware version, and the country ID in hexidecimal format (e.g., s0503a01v, 0,34). I7 Displays release information and V.92 capabilities. I9 Displays the country code in decimal format (e.g., 52). I11 Displays diagnostic information for the last modem connection, such as DSP and firmware version, link type, line speed, serial speed, type of error correction/data compression, number of past retrains, etc. Command: Ln Not Applicable Command: Mn Monitor Speaker Mode n = 0, 1, 2, or 3 1 M0 Speaker always off. M1 Speaker on until carrier signal detected. M2 Speaker always on when modem is off-hook. M3 Speaker on until carrier is detected, except while dialing. Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 9
10 Command: Nn Modulation Handshake n = 0 or 1 1 N0 Modem performs handshake only at communication standard specified by S37 and the B command. N1 Modem begins handshake at communication standard specified by S37 and the B command. During handshake, fallback to a lower speed can occur. Command: On Return to Online Data Mode 0, 1, 3 None O0 Exits online command and returns to data mode (see +++AT escape sequence). O1 Issues a retrain and returns to online data mode. O3 Issues a rate renegotiation and returns to data mode. Command: P Set Pulse Dial Default P, T T Configures the modem for pulse (non-touch-tone) dialing. Dialed digits are pulsed until a T command or dial modifier is received. Command: Qn Result Codes Enable/Disable n = 0 or 1 Q0 Enables result codes. Q1 Q2 Disables result codes. Dumb Answer Mode (also known as No Response Answer). Q2 sets the answer mode to be handled without responses and echo turned off; however, the originate mode remains intelligent. Command: Sr=n Set Register Value r = S-Register number; n varies None Sets the value of the register Sr to the value of n, where n is entered in decimal format: Example: S0=1. Command: Sr? Read Register Value r = S-Register number None Reads the value of the register Sr and displays it in 3-digit decimal form. Example: S2? gives the response 043. Command: T Set Tone Dial Default P, T T Configures the modem DTMF (touch-tone) dialing. Dialed digits are tone dialed until a P command or dial modifier is received. Command: Vn Result Code Format n = 0 or 1 1 V0 Displays result codes as digits (short form or terse). V1 Displays result codes as words (long-form or verbose). Command: Wn Result Code Options n = 0, 1, 2 2 W0 CONNECT result code reports serial port speed, disables protocol result codes. W1 CONNECT result code reports serial port speed, enables protocol result codes. W2 CONNECT result code reports line speed, enables protocol result codes. Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 10
11 Command: Xn Result Code Selection n = X0 Basic result codes (e.g., CONNECT); does not look for dial tone or busy signal. X1 Extended result codes (e.g., CONNECT V42bis); does not look for dial tone or busy signal. X2 Extended result codes with NO DIALTONE; does not look for busy signal. X3 Extended result codes with BUSY; does not look for dial tone. X4 Extended result codes with NO DIALTONE and BUSY. X5 Extended result codes with NO DIALTONE and BUSY. X6 Extended result codes with NO DIALTONE and BUSY. X7 Basic result codes with NO DIALTONE and BUSY. Command: Zn Modem Reset n = 0 or 1 None Z0 Resets modem to profile saved by the last &W command. Z1 Same as Z0. Command: &Cn Data Carrier Detect (DCD) Control n = 0, 1, or 2 1 &C0 Forces the DCD circuit to be always high. &C1 DCD goes high when the remote modem s carrier signal is detected, and goes low when the carrier signal is not detected. &C2 DCD drops on disconnect for time set by S18, then goes high again (for some PBX phone systems). Command: &Dn Data Terminal Ready (DTR) Control n = 0, 1, 2, or 3 2 &D0 Modem ignores the true status of the DTR signal and responds as if it is always on. &D1 If DTR drops while in online data mode, the modem enters command mode, issues an OK, and remains connected. &D2 If DTR drops while in online data mode, the modem hangs up. If the signal is not present, the modem will not answer or dial. &D3 If DTR drops, the modem hangs up and resets as if an ATZ command were issued. Command: &En XON/XOFF Pacing Control n = 12 or &E12 Disables XON/XOFF pacing. &E13 Enables XON/XOFF pacing. (&K4 must also be set.) Note: &E13 has no effect if hardware control (&K3) is selected. Command: &Fn Load Factory Settings n = 0 None &F0 Loads factory settings as active configuration. Note: See also the Z command. Command: &Gn V.22bis Guard Tone Control n = 0, 1, or 2 &G0 Disables guard tone. &G1 Sets guard tone to 550 Hz. &G2 Sets guard tone to 1800 Hz. Note: The &G command is not used in North America. Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 11
12 Command: &Kn Flow Control Selection n = 0, 3, or 4 Defaults: 3 &K0 Disables flow control. &K3 Enables CTS/RTS hardware flow control. &K4 Enables XON/XOFF software flow control. Command: &Ln Leased-Line Operation Note: This command applies to the MT5634IND (Industrial Temperature Modem) n = 0, 1, or 2 Defaults: 0 &L0 The modem is set for standard dial-up operation. Default. &L1 The modem is set for leased line operation in originate mode. &L2 The modem is set for leased line operation in answer mode. Note: For &L1 and &L2, there is a 30-second window between power up and the starting of the leased line handshake. During this time, you can turn off the command, if desired. Command: &Qn Asynchronous Communications Mode n = 0, 5, 6, 8, or 9 5 &Q0 Asynchronous with data buffering. Same as \N0. &Q5 Error control with data buffering. Same as \N3. &Q6 Asynchronous with data buffering. Same as \N0. &Q8 MNP error control mode. If MNP error control is not established, the modem falls back according to the setting in S36. &Q9 V.42 or MNP error control mode. If neither error control is established, the modem falls back according to the setting in S36. Command: &Sn Data Set Ready (DSR) Control n = 0 or 1 &S0 DSR is always high (on). &S1 DSR goes high only during a connection. Command: &Tn V.54 Test Commands n = 0, 1, 3 or 6 None &T0 Abort. Stops any test in progress. &T1 Initiates local analog loopback test. &T3 Initiates local digital loopback test. &T6 Initiates remote digital loopback test. Note: To stop a test, use the escape sequence (+++AT) before typing &T0. Command: &V Display Current Settings n/a Displays the active modem settings, including the callback security settings if callback security is enabled. If the setup password has been entered, it also displays the callback security passwords. Command: &Wn Store Current Configuration n = 0, 1 1 &W0 Stores current modem settings in nonvolatile memory and causes them to be loaded in place of the factory defaults at power-on or following the ATZ command. See also the &F command. &W1 Clears user default settings from nonvolatile memory and causes the factory defaults to be loaded at power-on or following the ATZ command. Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 12
13 Command: &Zn=x Storing a Dialing Command n = 0 3. Callback security disabled. 0, 1 used by MultiModemZPX/ZLI. 0, 1, 2 used by MultiModemZBA Callback security enabled. x = Stored telephone number None Stores dialing command x in memory. Dial the stored number using the command ATDS=n. See also the #CBSn command. Command: \An Select Maximum MNP Block Size n = 0, 1, 2, or 3 3 \A0 64-character maximum. \A1 128-character maximum. \A2 192-character maximum. \A3 256-character maximum. Command: \Bn Transmit Break n = 0 9 in 100 ms units 3 In non-error-correction mode only, sends a break signal of the specified length to a remote modem. Works in conjunction with the \K command. Command: \Kn Break Control n = Controls the modem s response to a break received from the computer, the remote modem, or the \B commnd. The response is different for each. Data mode. Modem receives the break from the computer: \K0 Enters online command mode, no break sent to the remote modem. \K1 Clears data buffers and send break to the remote modem. \K2 Same as \K0. \K3 Sends break immediately to the remote modem. \K4 Same as \K0. \K5 Sends break to the remote modem in sequence with the transmitted data. Data mode. Modem receives the break from the remote modem: \K0 Clears data buffers and sends break to the computer. \K1 Same as \K0. \K2 Sends break immediately to the computer. \K3 Same as \K2. \K4 Sends break to the computer in sequence with the received data. \K5 Same as \K4. Online command mode. Modem receives a \Bn command from the computer: \K0 Clears data buffers and sends break to the remote modem. \K1 Same as \K0. \K2 Sends break immediately to the remote modem. \K3 Same as \K2. \K4 Sends break to the remote modem in sequence with the transmitted data. \K5 Same as \K4. Command: \Nn Error Correction Mode Selection n = 0 5, or 7 3 \N0 Non-error correction mode with data buffering (same as &Q6). \N1 For compatibility. Operates the same as \N0. \N2 MNP reliable mode. If modem cannot make MNP connection, it disconnects. \N3 V.42/MNP auto-reliable mode. The modem attempts first to connect in V.42 error correction mode, then in MNP mode, and finally in non-error-correction (buffer) mode with continued operation. \N4 V.42 reliable mode.if the modem cannot make a V.42 connection, it disconnects. \N5 V.42, MNP, or non-error correction (same as \N3). \N7 V.42, MNP, or non-error correction (same as \N3). Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 13
14 Command: \Qn Flow Control Selection n = 0, 1, or 3 3 \Q0 Disables flow control (same as &K0). \Q1 XON/XOFF software flow control (same as &K4). \Q2 CTS-only flow control. Not supported. \Q3 RTS/CTS hardware flow control (same as &K3). Command: \Tn Inactivity Timer n = 0, \Tn Sets the time (in minutes) that the modem waits after the last character is sent or received before it disconnects. A value of zero disables the timer. Applies only in buffer mode. Note: You can also set the inactivity timer by changing the value of S30. Command: \Vn Protocol Result Code n = 0, 1, or 2 1 \V0 Disables the appending of the protocol result code to the DCE speed. \V1 Enables the appending of the protocol result code to the DCE speed. \V2 Same as \V1. Command: -Cn Data Calling Tone n = 0 or 1 Defaults: 0 -C0 Disables V.25 data calling tone to deny remote data/fax/voice discrimination. -C1 Enables V.25 data calling tone to allow remote data/fax/voice discrimination. Command: %A Adaptive Answer Result Code Enable n = 0 or 1 The %A command controls whether the DATA and FAX result codes will be sent by the modem. The modem must be in fax mode for this command to work. Also, the modem must be set to +FAA=1, which enables the modem to distinguish between a fax and a data call. When these commands are enabled, the modem sends DATA to the computer when it detects data tones, and FAX when it detects fax tones. These strings are used by some servers to select the appropriate communication program. %A0 Disables adaptive answer result codes. %A1 Enables adaptive answer result codes. Note: For descriptions of the +FAA= and other fax commands, see the Multi-Tech Fax Class 2.1 Developer s Guide. Command: %B View Numbers in Blacklist n/a If blacklisting is in effect, AT%B displays the numbers for which the last call attempted in the previous two hours failed. In countries that do not require blacklisting, the ERROR result code appears. Command: %Cn Data Compression Control n = 0 or 1 1 %C0 Disable sv.42bis/mnp 5 data compression. %C1 Enables V.42bis/MNP 5 data compression. Command: %DCn AT Command Control n = 0 or 1 %DC0 The modem responds to AT commands. %DC1 The modem ignores AT commands. Note: The modem will respond to AT%DC for 10 seconds after it is turned on. Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 14
15 Command: %DTn Set Command Mode Time in 1 second increments Sets the length of time that the command mode will be disabled when set for %DC1 (the modem ignores AT commands). Command: %En Fallback and Fall Forward Control n = 0, 1, or 2 2 %E0 Disables fallback and fall-forward. %E1 Enables fallback, disables fall-forward. %E2 Enables fallback and fall-forward. Command: %Hn Direct Connect Enable n = 0, 1 %H0 Sets callback security to normal operation. %H1 All callback security calls will be direct connect regardless of whether the password or phone number has the - character. Command: %Rn Cisco Configuration n = 0, 1 %R0 Disables Cisco configuration. %R1 Sets E0, Q1, &D0, \N0, $SB9600, and %S1 for operation with a Cisco router. Command: %Sn Command Speed Response n = 0, 1 %S0 Sets modem to respond to AT commands at all normal speeds. %S1 AT commands accepted at bps only. Other speeds are ignored. Command: $Dn DTR Dialing n = 0 or 1 $D0 Disables DTR dialing. $D1 Dials the number in memory location 0 when DTR goes high. Command: $EBn Asynchronous Word Length n = 0 or 1 $EB0 Enables 10-bit mode. $EB1 Enables 11-bit mode. Command: $FC Quick Connect n = 0, 1, or 2 Sets quick connect Syntax: AT$FC<value> $FC0 - No quick connect $FC1 - Sets quick connect speed at 1200 $FC2 - Sets quick connect speed at 2400 Command: $LB Long Break in 10 ms increments 30 (300 ms break) Sets the length of a long break transmitted by the modem if set up by the modem. Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 15
16 Command: $MBn Modem Baud Rate 75, 300, 1200, 2400, 4800, 9600, 14400, 19200, 28800, Presets the transmission baud rate for originate operations (i.e., the speed of the modem s transmissions over the telephone lines when originating a call). With speed conversion, transmission speed can be a different baud rate than the serial port speed. When the modem receives a call from another modem, it automatically switches its phone line transmission speed to match the calling mode. However, if the MultiModem originates a call to another modem that is unable to connect at the MultiModem s baud rate, it automatically drops to the lower baud rate in an attempt to match that modem s speed. For example, if the MultiModem is set for baud and calls a modem with a top speed of 2400 baud, it drops to 2400 baud. AT$MB75 = V.23 AT$MB300 = 300 bps AT$MB1200 = 1200 bps AT$MB2400 = 2400 bps AT$MB4800 = 4800 bps AT$MB9600 = 9600 bps AT$MB14400 = bps AT$MB19200 = bps AT$MB28800 = bps AT$MB33600 = bps Command: $RP Response Priority n = 0, 1 1 Configures whether an incoming ring or an AT command will have priority. $RP0 - AT command will have priority $RP1 - Incoming call (ring) will have priority Command: $SBn Serial Port Baud Rate n = speed in bits per second $SB300 Set serial port to 300 bps. $SB1200 Set serial port to 1200 bps. $SB2400 Set serial port to 2400 bps. $SB4800 Set serial port to 4800 bps. $SB9600 Set serial port to 9600 bps. $SB19200 Set serial port to bps. $SB38400 Set serial port to bps. $SB57600 Set serial port to bps. $SB Set serial port to bps. $SB Set serial port to bps. (V.92 models only) Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 16
17 V.92 Commands Command: +PCW=n Call Waiting Enable n = 0, 1, or 2 Controls the action to be taken upon detection of a call waiting tone in V.92 mode. Values specified by this command are not modified when an AT&F command is issued. +PCW=0 Toggles V.24 Circuit 125 and collects Caller ID if enabled by +VCID +PCW=1 Hangs up +PCW=2 Ignores V.92 call waiting +PCW=? Displays the allowed values +PCW? Displays the current value Command: +PIG=n PCM Upstream Enable n = 0 or 1 1 Controls the use of PCM upstream during V.92 operation. PCM upstream allows faster upload speeds to a V.92 server. +PIG=0 Enable PCM upstream +PIG=1 Disable PCM upstream +PIG=? Displays the allowed values +PIG? Displays the current value Command: +PMH=n Modem on Hold Enable n = 0 or 1 1 Controls if modem on hold procedures are enabled during V.92 operation. Normally controlled by a modem on hold program. Values specified by this command are not modified when an AT&F command is issued. +PMH=0 Enables V.92 modem on hold +PMH=1 Disables V.92 modem on hold +PMH=? Displays the allowed values +PMH? Displays the current value Command: +PMHF V.92 Modem Hook Flash n/a n/a Causes the DCE to go on-hook for a specified period of time, and then return off-hook for at least a specified period of time. The specified period of time is normally one-half second, but may be governed by national regulations. ERROR is returned if MOH is not enabled. Command: +PMHR=n Modem on Hold Initiate n = PMHR is an action command that causes the modem to initiate MOH with the central site modem. It returns the following values to indicate negotiated values. Valid only if MOH is enabled and the modem is off-hook or in data mode. Otherwise, ERROR will be returned. +PMHR=0 Deny MOH request +PMHR=1 Grant MOH request with 10 second timeout +PMHR=2 Grant MOH request with 20 second timeout +PMHR=3 Grant MOH request with 30 second timeout +PMHR=4 Grant MOH request with 40 second timeout +PMHR=5 Grant MOH request with 1 minute timeout +PMHR=6 Grant MOH request with 2 minute timeout +PMHR=7 Grant MOH request with 3 minute timeout +PMHR=8 Grant MOH request with 4 minute timeout +PMHR=9 Grant MOH request with 6 minute timeout +PMHR=10 Grant MOH request with 8 minute timeout +PMHR=11 Grant MOH request with 12 minute timeout +PMHR=12 Grant MOH request with 16 minute timeout +PMHR=13 Grant MOH request with indefinite timeout +PMHR=? Displays the allowed values +PMHR? Displays the current value Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 17
18 Command: +PMHT=n Modem on Hold Timer n = 0 13 Determines if the modem will accept a V.92 Modem on Hold request; sets the MoH timeout. +PMHT=0 Deny MOH request +PMHT=1 Grant MOH request with 10 second timeout +PMHT=2 Grant MOH request with 20 second timeout +PMHT=3 Grant MOH request with 30 second timeout +PMHT=4 Grant MOH request with 40 second timeout +PMHT=5 Grant MOH request with 1 minute timeout +PMHT=6 Grant MOH request with 2 minute timeout +PMHT=7 Grant MOH request with 3 minute timeout +PMHT=8 Grant MOH request with 4 minute timeout +PMHT=9 Grant MOH request with 6 minute timeout +PMHT=10 Grant MOH request with 8 minute timeout +PMHT=11 Grant MOH request with 12 minute timeout +PMHT=12 Grant MOH request with 16 minute timeout +PMHT=13 Grant MOH request with indefinite timeout +PMHT=? Displays the allowed values +PMHT? Displays the current value Command: +PQC=n Quick Connect Control n = 0, 1, 2, or 3 3 Controls the V.92 shortened Phase 1 and Phase 2 startup procedures (Quick Connect). When line conditions are stable, quick connect results in shortened connect times; however, significant fluctuation in line conditions from call to call can result in longer connect times, in which case it may be advisable to disable quick connect. +PQC=0 Enables Short Phase 1 and Short Phase 2 (Quick Connect) +PQC=1 Enables Short Phase 1 +PQC=2 Enables Short Phase 2 +PQC=3 Disables Short Phase 1 and Short Phase 2 +PQC=? Displays the allowed values +PQC? Displays the current value Command: +DCS=x,y Select V.44 Data Compression x = 0 or 1 (V.42bis) y = 0, 1, or 2 (V.44) 1, 2 Selects V.42bis/V.44 data compression. +DCS=0,0 V.42bis and V.44 data compression are both disabled. +DCS=0,1 V.42bis is disabled; V.44 data compression is acceptable. +DCS=0,2 V.42bis is disabled; V.44 only when connected to a V.92 server. +DCS=1,0 V.42bis is acceptable; V.44 data compression is disabled. +DCS=1,1 V.42bis is acceptable; V.44 data compression is acceptable. +DCS=1,2 V.42bis is acceptable; V.44 only when connected to a V.92 server. +DCS=? Displays the allowed values. +DCS? Displays the current value. Command: +DR=n V.44 Data Compression Reporting n = 0 or 1 Enables or disables the V.44 data compression report. If the compression report is enabled, the +DR:<type> intermediate result code reports the current DCE-DCE data compression type. It is issued after the Error Control Report (+ER) and before the final result code (e.g., CONNECT). The intermediate result code descriptions are shown after the command - descriptions. +DR=0 Disables the V.44 compression report. +DR=1 Enables the V.44 compression report. +DR=? Displays the allowed values. +DR? Displays the current value. +DR: NONE Data compression not in use. +DR: V42B V.42bis is in use in both directions. +DR: V44 V.44 is in use in both directions. Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 18
19 Command: +DS44=n V.44 Data Compression See description See description Controls the V.44 data compression function. The command syntax is +DS44=[direction][,[0][,[0] [,[max_codewords_tx][,[max_codewords_rx][,[max_string_tx] [,[max_string_rx][,[max_history_tx][,[max_history_rx]]]]]]]]]<cr> Subparameters that are not entered retain their current value. Commas separate optional subparameters, and must be inserted to skip a subparameter. Example: +DS44=,,,2048,2048<CR> changes the maximum number of code words in both directions, and keeps all other settings at their current values. +DS44=? Reports supported options in the format (list of supported direction values), (0), (0), (list of supported max_codewords_tx values), (list of supported max_codewords_rx values), (list of supported max_string_tx values), (list of supported max_string_rx values), (list of supported max_history_tx values), (list of supported max_history_rx values). Example: +DS44: (3, 0), (0), (0), ( ), ( ), (31-255), (31-255), ( ), ( ). +DS44? Reports current options in the following format: direction, 0, 0, max_codewords_tx, max_codewords_rx, max_string_tx, max_string_rx, max_history_tx, max_history_rx. Example: +DS44: 3, 0, 0, 1024, 1024, 255, 255, 5120, Subparameters direction max_codewords_tx max_codewords_rx max_string_tx max_string_rx max_history_tx max_history_rx Specifies the DTE direction of the data compression. 0 No compression. 3 Compression in both directions (default). Specifies the maximum number of code words to be negotiated in the transmit direction Default Maximum number of code words in transmit direction. Specifies the maximum number of code words to be negotiated in the receive direction Default Maximum number of code words in receive direction. Specifies the maximum string length to be negotiated in the transmit direction. 255 Default Maximum string length in transmit direction. Specifies the maximum string length to be negotiated in the receivedirection. 255 Default Maximum string length in receivedirection. Specifies the maximum length of the history buffer to be negotiated in the transmit direction Default History buffer size in transmit direction. Specifies the maximum length of the history buffer to be negotiated in the receive direction Default History buffer size in receive direction Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 19
20 Command: Defaults: +MS= Modulation Selection See description. See description. This extended-format command selects modulation, enables or disables automode, and specifies the highest downstream and upstream connection rates using one to four subparameters. The command syntax is: +MS= [mod][,[automode][,[0][,[max_rate][,[0][,[max_rx_rate]]]]]]<cr> Subparameters that are not entered retain their current value. Commas separate optional subparameters, and must be inserted to skip a subparameter. Example: +MS=,0<CR> disables automode and keeps all other settings at their current values. +MS=? Reports supported options in the format (list of supported mod values),(list of supported automode values),(0),(list of supported max_rate values),(0),(list of supported max_rx_rate values). Example: +MS: (BELL103, V21, BELL212A, V22, V22B, V23C, V32, V32B, V34, +MS? V90, V92), (0, 1), (0), ( ), (0), ( ) Reports current options in the format mod, automode, 0, max_rate, 0, max_rx_rate. Example: +MS: V92, 1, 0, 31200, 0, Subparameters mod automode max_rate max_rx_rate Specifies the preferred modulation (automode enabled) or the modulation to use in originating or answering a connection (automode disabled). The default is V92. mod Modulation Possible rates (bps) 1 V92 2 V , 54666, 53333, 52000, 50666, 49333, 48000, 46666, 45333, 44000, 42666, , 38666, 37333, 36000, 34666, 33333, 32000, 30666, 29333, or V90 3 V , 54666, 53333, 52000, 50666, 49333, 48000, 46666, 45333, 44000, 42666, , 38666, 37333, 36000, 34666, 33333, 32000, 30666, 29333, or V34 V , 31200, 28800, 26400, 24000, 21600,19200, 16800, 14400, 12000, 9600, 7200, 4800, or 2400 V32B V.32bis 14400, 12000, 9600, 7200, or 4800 V32 V or 4800 V22B V.22bis 2400 or 1200 V22 V V23C V V21 V Bell212A Bell 212A 1200 Bell103 Bell Notes: 1. See optional <automode>, <max_rate>, and <max_rx_rate> subparameters. 2. Selects V.92 modulation as first priority. If a V.92 connection cannot be established, the modem attempts V.90, V.34, V.32bis, etc. 3. Selects V.90 modulation as first priority. If a V.90 connection cannot be established, the modem attempts V.34, V.32bis, etc. An optional numeric value that enables or disables automatic modulation negotiation using V.8 bis/v.8 or V.32 bis Annex A. Automode is disabled if values are specified for the max_rate and max_rx_rate parameters. The options are: 0 Disable automode 1 Enable automode (default) An optional number that specifies the highest rate at which the modem may establish an upstream (transmit) connection. The value is decimal coded in units of bps, for example, specifies the highest rate to be bps. 0 Maximum rate value limited by the modulation selected in mod (default) Maximum rate value limited by the modulation selected in mod. For valid max_rate values for each mod value, see the following table: mod value Valid max-rate values (bps) V92, V90, V , 28800, 26400, 24000, 21600,19200, 16800, 14400, 12000, 9600, 7200, 4800, 2400 V32B 19200, 16800, 14400, 12000, 9600, 7200, 4800 V , 12000, 9600, 7200, 4800 V22B 2400 V22, V23C, Bell212A 1200 V21, Bell An optional number that specifies the highest rate at which the modem may establish a downstream (receive) connection. The value is decimal coded in bps units; e.g., specifies the highest rate to be bps. 0 Maximum rate determined by the modulation selected in mod (default) Maximum rate value limited by the modulation selected in mod. See Possible rates in the mod table. Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 20
21 Caller ID Commands Command: +VCID=n Caller ID Selection n = 0, 1, or 2 Enables Caller ID detection and configures the reporting and presentation of the Caller ID data that is detected after the first ring. The reported data includes the date and time of the call, the caller's name and number, and a message. Set S0=2. +VCID=0 Disables Caller ID +VCID=1 Enables Caller ID with formatted data +VCID=2 Enables Caller ID with unformatted data +VCID=? Displays the allowed values +VCID? Displays the current value Command: +VDR=x,y Distinctive Ring Report x = 0, 1 Distinctive Ring report control. See description. y = Minimum ring interval in 100 ms units. See description. Enables reporting of ring cadence information to the DTE and specifies the minimum ring cadence that will be reported. The report format is one line per silence period and one line per ring period. The length of the silence period is in the form DROF=number in units of 100 ms<cr><lf>, and the length of the ring is in the form DRON=number in units of 100 ms<cr> <LF>. The modem may produce a Ring event code after the DRON message if enabled by the y parameter. The y parameter must be set to a value equal to or smaller than the expected ring cadence in order to pass the report to the DTE. +VDR=0, n/a Disables Distinctive Ring cadence reporting. +VDR=1, 0 Enables Distinctive Ring cadence reporting. Other call progress result codes (including RING) are reported as normal. +VDR=1, >0 Enables Distinctive Ring cadence reporting. The RING result code is reported after the falling edge of the ring pulse (i.e., after the DRON report). +VDR=? Displays the allowed values. +VDR? Displays the current value. Command: +VRID Caller ID Query na na Displays Caller ID information of the last call received. Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 21
22 Callback Security Commands Command: #CBAn Callback Attempts n = Sets the number of callback attempts that are allowed after passwords have been exchanged between modems. Command: #CBDn Callback Delay n = Sets the length of time (in seconds) that the modem waits before calling back the remote modem. Command: #CBF? Callback Failed Attempts Display n/a n/a Requests the number of failed callback passwords since reset or power-up. This number can be stored to nonvolatile memory using the &W command. Command: #CBFR Callback Failed Attempts Reset n/a n/a Resets the number of failed callback passwords to 0. This does not reset the number stored in nonvolatile memory. Command: #CBIn Local Callback Inactivity Timer n = Sets the time (in minutes) that the modem waits for a command before forcing the user to enter the setup password again. Command Store Callback PCommand: #CBNy=x Store Callback Password y = 0 29 x = password Defaults: None Sets the callback security password for the y memory location. The password must have 6 to 10 characters, and cannot include the + or - characters. Command: #CBPn Callback Parity n = 0, 1, or 2 Sets parity for the callback security messages. #CBP0 No parity. #CBP1 Odd parity. #CBP2 Even parity. Command: #CBRy Callback Security Reset y = 0 29 None Clears the password and phone number in the y memory location. Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 22
23 Command: #CBSn Callback Enable/Disable n = 0, 1, 2, or 3 #CBS0 Disables callback security. #CBS1 Enables local and remote callback security. #CBS2 Enables remote callback security only. #CBS3 #CBS4 Command: #Pn Set 11-bit Parity n = 0 or 1 2 #P0 No parity. #P1 Odd parity. #P2 Even parity. Disables callback security until local hangup or reset. Enables a callback security modem to originate a call without a connection password prompt. Command: #Sx Enter Setup Password x= password (1 8 characters, case sensitive) MTSMODEM Enters the callback security setup password. Command: #S=x Store Setup Password x= password (1 8 characters, case sensitive) MTSMODEM Stores a new callback security and remote configuration setup password. Escape Sequence Commands Command: Escape Sequence+++AT<CR> Escape Sequence n/a Puts the modem in command mode (and optionally issues a command) while remaining online. Type +++AT and up to six command characters, then press ENTER. Used mostly to issue the hang-up command: +++ATH<CR>. Command: Escape Configuration for Remote Configuration%%%ATMTSMODEM<CR> Remote Configuration Escape Sequence n/a Initiates remote configuration mode while online with remote modem. The remote configuration escape character (%) is defined in register S9. Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 23
24 DID Commands The DID modem uses *D commands to configure the modem s DID features. The modem must be configured for the proper protocol, digit format, digit time out, digit report format, and number of digits. This configuration is determined by the company from which the DID line is ordered and the setup used by the phone company. The DID configuration parameter settings of the modem can be viewed as part of the report of the AT&V command and can be stored with AT&X0 command. Command: *DS Start Protocol n = 0, 1, 2 or 3 There are three different types of DID start protocols: Wink, Immediate, and Delay Dial. In the Wink Start protocol, the central office closes the loop and draws current. The modem senses the current draw and will reverse the DC polarity for a short pulse to sign that it sees the incoming call and is ready to accept the DID digits. Delay Dial is the same as Wink Start with the exception that the length of the reverse pulse is not defined. When the DID modem senses the current draw, it will reverse the DC voltage until it is ready to receive the DID digits. On an Immediate Start DID line, the central office closes the loop for a short time and then sends the DID digits without waiting for a response from the DID modem. After the central office sends the DID digits all three lines operate the same way. The modem will reverse the DC polarity to signal the beginning of the call and the central office will open the channel to the caller and begin billing. When the call is completed, the DID modem will return the DC voltage to normal polarity and the central office will open the circuit. While the modem is monitoring the DID line for current draw, it is also monitoring the POTS line for incoming rings. *DS0 Disables DID detection of incoming DID calls (DC voltage still applies to DID line) *DS1 Wink Start *DS2 Immediate Start *DS3 Delay Dial Command: *DT Wait for Digit Time-Out Time DTn - n=0-30 seconds This command is used to configure the time between each digit the modem will wait. If the modem has not received the proper number of digits when the timer expires, it will report the digits it has received so far and move on to the answering sequence described in the *DN command. Command: *DD Digit Format 0, 1, 2 This command is used to configure the modem for the format the central office will send the incoming digits. At this time, only DTMF is supported. *DD0 DTMF *DD1 Pulse *DD2 MF (MultiFrequency) Command: *DN Number of DID Digits Expected 0-7 This command is used to configure the modem for the expected number of digits from the central office (the central office will send the last few digits of the called number). When the proper number of digits are received, the modem will pass the digit information to the host computer. After passing the digits the modem will answer the incoming call if S0 is greater than 0. Otherwise the modem will wait for the host computer to issue an ATA command. Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 24
25 Command: *DW Busy-Out Timer at End of Call This command defines the amount of time to busy out the modem upon disconnecting from a DID call. The delay is ended when the timer runs out or a *DS command is received. *DW0 This command disables the delay. It ends the delay, but it also places the DID line a busy-out state. *DW255 This command will extend the delay indefinitely. About the Busy-Out Features and Functions A Direct Inward Dial (DID) line can be put in a Busy Out state by reversing the battery polarity the modem supplies to the line. This will cause a caller to receiver either a busy signal in a single line system or roll over to the next line in a trunk system. The line is busied out in the following cases. - Modem is set to the factory default DID start format *DS0 - Modem receives an incoming ring on the POTS line - Modem is given the dial command ATD - Modem is set with the *DW command to busy-out delay after finishing a call Command: *DF Format for Reporting Incoming DID Number 0, 1, 2 This command allows for three different reporting formats of the incoming number information. This information is output when either the proper number of digits have been received or the time out timer has expired and before the modem answers the call. When set to *DFI, the modem will output one line for every digit received. For the other formats, the modem will only output one line per call. *DF0 DID:xxx - Default *DF1 DTMFx for each digit *DF2 RINGxxx Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 25
26 Chapter 2 S-Registers Chapter 2 - S-Registers Certain modem values, or parameters, are stored in memory locations called S-Registers. Use the S command to read or to alter the contents of S-Registers (see previous section). Notes: Range and Default are dependent upon the Country Code you are using. The ranges and defaults below are for North America and Europe. Examples of other country ranges and defaults are given at the end of this chapter. Register Unit Range Default Description S0 1 ring , 1 Sets the number of rings until the modem answers. ATS0=0 disables autoanswer completely. Set S0=2 for Caller ID. Internal Modem Default is 0. External Modem Default is 1 S1 1 ring Counts the rings that have occurred. S2 decimal Sets ASCII code for the escape sequence character. Values greater than 127 disable escape. S3 decimal Sets the ASCII code for the carriage return character. S4 decimal Sets the ASCII code for line feed character. S5 decimal Sets the ASCII code for the backspace character. Values over 32 disable it. S6 seconds Sets the time the modem waits after it goes off-hook before it begins to dial the telephone number. S7 seconds Sets the time the modem waits for a carrier signal before aborting a call. Also sets the wait-for-silence time for dial modifier. S8 seconds Sets the length of a pause caused by a comma character in a dialing command. S9 decimal Sets ASCII code for remote configuration escape character. S9=0 disables remote configuration. S ms Sets how long a carrier signal must be lost before the modem disconnects. S11 1 ms Sets spacing and duration of dialing tones. S18 50 ms Sets the time the Callback Delay signal drops before going high again. Used for some PBX and CBX phone systems. See &C2 command. S28 decimal disables, enables V.34 modulation. S30 1 minute Sets the time the modem waits before it disconnects when no data is sent or received. A value of zero disables the timer. See also the \T command S35 decimal disables, 1 enables the V.25 data calling tone, which allows remote data/fax/voice discrimination. S36 decimal Specifies the action to take in the event of a negotiation failure when error control is selected. (See S48.) Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 26
27 Chapter 2 S-Registers Register Unit Range Default Description S37 decimal Sets the maximum V.34 upstream speed at which the modem attempts to connect. Value Speed 0 maximum modem speed 1 reserved /75 bps bps 4 reserved bps bps bps bps bps bps bps bps bps bps bps bps bps bps bps S38 decimal Sets the maximum 56K downstream speed at which the modem attempts to connect. The default maximum speed is 56K bps. Note: When using V.34 or V.32 client-to-client connections in poor conditions, setting S38=0 may result in better performance. Value Rate 0 56K disabled 1 56K autorate bps bps bps bps bps bps bps bps bps bps bps bps bps bps bps bps bps bps bps bps bps bps S42 decimal Enables/disables the 56K auto rate. When 56K auto is disabled, fallback to V.34 is also disabled. 0 = disable; 1 = enable. Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 27
28 Chapter 2 S-Registers Register Unit Range Default Description S48 decimal 7 or Enables (7) or disables (128) LAPM negotiation. The following table lists the S36 and S48 configuration settings for certain types of connections. S48=7 S48=128 S36=0, 2 LAPM or Hangup Do not use S36=1, 3 LAPM or Async Async S36=4, 6 LAPM, MNP, or Hangup MNP or Hangup S36=5, 7 LAPM, MNP, or Async MNP or Async S89 seconds Sets the length of time in the off-line command mode before the modem goes into standby mode. A value of zero prevents standby mode; a value of 1 4 sets the value to 5. S108 decimal Selects the 56K digital loss if using the modem thru a PBX line. The default value is -6 db loss, the value used when calling from a typical POTS line long distance. Value Digital loss 0-0 db digital loss, no robbed-bit signaling 1-3 db PBX digital loss 2-2 db digital loss 3-3 db digital loss 6-6 db digital loss 7-0 db digital loss with robbed-bit signaling S109 decimal Selects the 56K operating mode. Value 56K mode 0 56K mode (V.90 disabled) 1 Dual mode (56K or V.90) 2 V.90 mode (56K disabled) Examples of Ranges and Defaults Determined by Country Codes Register Country Code 16: Country Code 48: Country Code 1: Country Code 9: Japan Hong Kong Australia New Zealand Range Default Range Default Range Default Range Default S S S S S S S S S S S S S S S S S or S S S S S S S Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 28
29 Chapter 3 Result Codes Chapter 3 - Result Codes In command mode your modem can send responses called result codes to your computer. Result codes are used by communications programs and are displayed on your monitor. Terse Verbose Description 0 OK Command executed 1 CONNECT Modem connected to line 2 RING Ring signal detected 3 NO CARRIER Carrier signal lost or not detected 4 ERROR Invalid command 5 CONNECT 1200 * Connected at 1200 bps 6 NO DIALTONE No dial tone detected 7 BUSY Busy signal detected 8 NO ANSWER No answer at remote end 10 CONNECT 2400 * Connected at 2400 bps 11 CONNECT 4800 * Connected at 4800 bps 12 CONNECT 9600 * Connected at 9600 bps 13 CONNECT * Connected at bps 14 CONNECT * Connected at bps 24 CONNECT 7200 * Connected at 7200 bps 25 CONNECT * Connected at bps 26 CONNECT * Connected at bps 40 CONNECT 300 * Connected at 300 bps 55 CONNECT * Connected at bps 56 CONNECT * Connected at bps 57 CONNECT * Connected at bps 58 CONNECT * Connected at bps 59 CONNECT * Connected at bps 60 CONNECT * Connected at bps 70 CONNECT * Connected at bps, 56K rate 71 CONNECT * Connected at bps, 56K rate 72 CONNECT * Connected at bps, 56K rate 73 CONNECT * Connected at bps, 56K rate 74 CONNECT * Connected at bps, 56K rate 75 CONNECT * Connected at bps, 56K rate 76 CONNECT * Connected at bps, 56K rate 77 CONNECT * Connected at bps, 56K rate 78 CONNECT * Connected at bps, 56K rate 79 CONNECT * Connected at bps, 56K rate 80 CONNECT * Connected at bps, 56K rate 81 CONNECT * Connected at bps, 56K rate 82 CONNECT * Connected at bps, 56K rate 88 DELAYED Delay is in effect for the dialed number 89 BLACKLISTED Dialed number is blacklisted 90 BLACKLIST FULL Blacklist is full 100 CONNECT * Connected at bps, 56K rate 101 CONNECT * Connected at bps, 56K rate 102 CONNECT * Connected at bps, 56K rate 103 CONNECT * Connected at bps, 56K rate 104 CONNECT * Connected at bps, 56K rate 105 CONNECT * Connected at bps, 56K rate 106 CONNECT * Connected at bps, 56K rate 107 CONNECT * Connected at bps, 56K rate 108 CONNECT * Connected at bps, 56K rate 109 CONNECT * Connected at bps, 56K rate 110 CONNECT * Connected at bps, 56K rate 111 CONNECT * Connected at bps, 56K rate 112 CONNECT * Connected at bps, 56K rate 113 CONNECT * Connected at bps, 56K rate 114 CONNECT * Connected at bps, 56K rate 115 CONNECT * Connected at bps, 56K rate 116 CONNECT * Connected at bps, 56K rate * When the extended result code configuration option is enabled, one of the following codes is appended to the result code, depending on the type of error control connection: V42bis V.42 error control (LAP-M) and V.42bis data compression V42 V.42 error control (LAP-M) only MNP5 MNP 4 error control and MNP 5 data compression MNP4 MNP 4 error control only NoEC No error control protocol Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 29
30 Chapter 4 Setting Your Country or Regional Code Chapter 4 Setting Your Country or Regional Code Note: This chapter applies to global modems only. Different countries/regions have different requirements for how modems must function. Therefore, before you use the modem, you must configure it to match the defaults of the country/region in which you are using it. To configure the modem for a specific country/region, execute the following AT commands: 1. Type AT%T19,0,nn (nn stands for the country/region code). Press Enter. OK is displayed. 2. Then save the changes by issuing the following command: AT&F&W 3. To verify that the correct code has been configured, issue the following command: ATI9 The country/region code is then displayed in decimal format. The following is an example of country/region, AT commands, and result codes. Country/Region AT Command (Hexadecimal) Result Code (Decimal) Euro/NAM* AT%T19,0,34 (default) 52 Australia AT%T19,0,01 1 Czech Republic AT%T19,0,25 37 Japan AT%T19,0,10 16 New Zealand AT%T19,0,9 9 Countries/Regions Supported See the list on the Multi-Tech Web site for countries and regions supported. The Global Modem Country/Region Approvals displays at the bottom of the page. On this page you can view approvals, configuration strings (includes the country/regional code) and responses available in list form by selecting country/region and/or product. Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 30
31 Index Index 1 11-Bit Mode A Abort Timer S Adaptive Answer Result Code Enable %A Answer A... 8 Asynchronous Communications Mode &Q Asynchronous Word Length $EB AT Command Control %DC AT commands $D DTR Dialing $EB Asynchronous Word Length $FC Quick Connect $LB Long Break $MB Modem Baud Rate $RP Response Priority $SB Serial Port Baud Rate %%%ATMTSMODEM Escape Configuration for Remote Configuration %A Adaptive Answer Result Code Enable %B View Numbers in Blacklist %C Data Compression Control %DC AT Command Control %DT Set Command Mode Time %E Fallback and Fall Forward Control %H Direct Connect Enable %M Enable Dialing Message... 9 %R Cisco Configuration %S Command Speed Response &C DCD Control &D DTR Control &E XON/XOFF Pacing &F Load Factory Settings &G V.22bis Guard Tone Control &K Flow Control Selection &L Leased-Line Operation &Q Asynchronous Communications Mode &S Data Set Ready (DSR) Control &T V.54 Test &V Display Current Settings &W Store Current Configuration &Z= Storing a Dialing Command AT Escape Sequence DCS= Select V.44 Data Compression DR= V.44 Data Compression Reporting DS44= V.44 Data Compression MS= Modulation Selection PCW= Call Waiting Enable PIG= PCM Upstream Enable PMH= Modem on Hold Enable PMHF V.92 Modem Hook Flash PMHR= Modem on Hold Initiate PMHT= Modem on Hold Timer PQC= Quick Connect Control VCID= Caller ID Selection VDR= Distinctive Ring Report VRID Caller ID Query A Answer... 8 \A Select Maximum MNP Block Size A/ Repeat... 8 AT Attention Code... 8 B Communication Standard Setting... 8 \B Transmit Break C Data Calling Tone D Dial... 8 DS=n Dial Stored Telephone Number... 9 E Echo... 9 F Echo Online Data Characters... 9 H Hook Control... 9 I Information Request... 9 \K Break Control M Monitor Speaker Mode... 9 \N Error Correction Mode Selection N Modulation Handshake O Return Online to Data Mode P Pulse Dialing \Q Flow Control Selection Q Result Codes Enable/Disable Sr? Read Register Value Sr= Set Register Value \T Inactivity Timer T Tone Dialing \V Protocol Result Code V Result Code Form W Result Code Options X Result Code Selection Z Modem Reset AT Commands Definition... 4 Attention Code AT... 8 Autoanswer S B Backspace Character Setting S Blacklisting %B Break Control \K Busy-Out Timer at End of Call *DW C Call Waiting Enable +PCW= Callback Attempts #CBA Callback Delay #CBD Callback Enable/Disable #CBS Callback Failed Attempts Display #CBF? Callback Failed Attempts Reset #CBFR Callback Parity #CBP Callback Security commands #CBA Callback Attempts #CBD Callback delay #CBF? Callback Failed Attempts Display #CBFR Resetting Failed Attempts #CBI Local Inactivity Timer #CBN= Store Callback Password Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 31
32 Index #CBP Callback Parity #CBR Callback Security Reset #CBS Callback Enable/Disable #P Set 11-bit Parity #S Enter Setup Password #S= Store Setup Password Callback Security Reset #CBR Caller ID Query +VRID Caller ID S Caller ID Selection +VCID= Carriage Return Character S Carrier Loss Disconnect Time S Cisco Configuration %R Command Mode Description... 4 Command Mode Time %DT Command Speed Response %S Command String... 4 Communication Standard Setting B... 8 Compression Control %C Configuration Storing &W Country Code Display I Country or Regional Code Setting D Data Calling Tone C Data Calling Tone S Data Carrier Detect &C Data Compression Control %C Data Mode Description... 4 Data mode O Data Set Ready ControL &S Data Terminal Ready &D DCD Control &C Default Settings &F Default Settings Cleared &W Definition of an AT Command... 4 Delay Timer S Diagnostic Information Display I Dial D... 8 Dial Stored Telephone Number DS=n... 9 Dialing Tones S DID commands *DD Digit Format *DF Format for Reporting Incoming DID Number *DN Number of DID Digits Expected *DS Start Protocol *DT Wait for Digit Time-Out Time *DW Busy-Out Timer DID Start Protocol *DS Digit Format *DD Digital Loss (56K) with PBX S Direct Connect Enable %H Disconnect Delay S Display Current Settings &V Distinctive Ring +VDR= DSR Control &S DTR (Data Terminal Ready) Control &D DTR Dialing $D E Echo E... 9 Echo Online Data Characters F... 9 Enable Dialing Message %M... 9 Enable V.34 Modulation S Enable/Disable 56K Auto Rate S Enter Setup Password #S Error Control Setting S Error Control Setting S Error Correction Mode Selection \N Escape Character S Escape Sequence +++AT Escape Sequence Description... 4 Escape Sequence for Remote Configuration %%%ATMTSMODEM F Factory Default Settings &W Fallback and Fall Forward %E Firmware Version Display I Firmware Version Display I Flow Control Selection &K Flow Control Selection \Q Format for Entering AT Commands... 4 Format for Reporting Incoming DID Number *DF G Guard Tone Control &G H Hangup Delay S Hangup H... 9 Hook Control H... 9 I Inactivity Timer S Inactivity Timer \T Information Request I... 9 Initialization String... 4 L Leased-Line Operation &L Line Feed Character S Load Factory Settings &F Local Callback Inactivity Timer #CBI Long Break $LB M Maximum 56K Connect Speed S Maximum Speed S MNP 5 Data Compression %C MNP Error Correction \N Modem Baud Rate $MB Modem on Hold Enable +PMH= Modem on Hold Initiate +PMHR= Modem on Hold Timer +PMHT= Modem Reset Z Modulation Handshake N Modulation Selection +MS= Monitor Speaker Mode M... 9 Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 32
33 Index N Number of DID Digits Expected *DN O On-hook/off-hook H... 9 Online Command Mode Description... 4 P Parity Setting #P Pause Time for Comma Setting S PCM Upstream Enable +PIG= Protocol Result Code \V Pulse Dialing P Q Quick Connect $FC Quick Connect Control +PQC= R Read Register Value Sr? Remote Configuration Escape Character S Repeat A/... 8 Resetting the Modem &F Response Priority $RP Result Code Form V Result Code Options W Result Code Selection X Result Codes Chapter Result Codes Description... 4 Result Codes Enable/Disable Q Result Codes Protocol \V Return Online to Data Mode O Rings S0, Setting Number of ROM Checksum I S Select Maximum MNP Block Size \A Select V.44 Data Compression +DCS= Selects 56K Operating Mode S Serial Port Baud Rate $SB Set 11-bit Parity #P Set Register Value Sr= Setting Country or Regional Code Speaker Mode M... 9 Speed Maximum S S-Registers S S S S S S S S S S S S S S S S S S S S S S S S S-Registers Chapter Standby Mode Delay Time S Store Callback Password #CBN= Store Current Configuration &W Store Setup Password #S= Storing a Dialing Command &Z= and &W T Testing the Modem &T Tone Dialing T Transmit Break \B V V.22bis Guard Tone Control &G V.25 Data Calling Tone -C V.25 Data Calling Tone S V.42 Error Correction \N V.42bis Data Compression %C V.44 Data Compression +DCS= V.44 Data Compression +DS44= V.44 Data Compression Reporting +DR= V.54 Tests &T V.92 Commands Chapter V.92 Modem Hook Flash +PMHF View Numbers in Blacklist %B W Wait for Digit Time-Out *DT Wait Time for Dial Tone S X XON/XOFF Pacing Control &E Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 33
FAX/DATA MODEM USER'S MANUAL
FAX/DATA MODEM USER'S MANUAL Notice: Hayes is a trademark of Microcomputer Products Inc. Publication Number : ASK9705 Table of Contens i - FCC/DOC REQUIREMENTS i.1 FCC General Information i.2 FCC Notice
Low Speed Modems for Dial and Leased Circuits 2400E-2 (Stand Alone) 2400R-2 (Rack Mount) 2400E-4 (Stand Alone) 2400R-4 (Rack Mount)
Low Speed Modems for Dial and Leased Circuits 2400E-2 (Stand Alone) 2400R-2 (Rack Mount) 2400E-4 (Stand Alone) 2400R-4 (Rack Mount) QUALITY COMMUNICATIONS PRODUCTS Made in the U.S.A. 11-1010-002 INTRODUCTION
PCM-3600 PC/104 Fax/Modem Module
PCM-3600 PC/104 Fax/Modem Module Copyright Notice This document is copyrighted, 1996, by AAEON Technology Inc. All rights are reserved. AAEON Technology Inc. reserves the right to make improvements to
Dial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) 5019-1 Manual Rev A + - DLM CTS RTS DTR DSR
AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) 5019-1 Manual Rev A User Manual + - CD CTS RTS DTR. DSR RI RX TX PHONE LINE DLM Dial-Up / Leased-Line Modem Dial-Up / Leased-Line Modem CONTENTS
Configuration Guide for Ascom Communications Server, Remote Management Package
Configuration Guide for Ascom Communications Server, Remote Management Package Introduction This document outlines the necessary steps and guidelines to configure the Ascom Communications Server, Remote
System Requirements. Hiro H50113
1 Hiro H50113 System Requirements Hiro H50113 Computer with Pentium 200 MMX or higher processor. Windows 2000, Windows XP Home / Professional, XP Professional x64 Edition, Vista 32 / 64 Families, Windows
1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.
SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS WINLOAD MODEM SETUP The modem setup is a very important step in the connection process. If the modem setup is not properly completed communication between
18.04.2005 version 3.1. Security modem with USB port user guide
18.04.2005 version 3.1 Security modem with USB port user guide Introduction Congratulations on selecting the new SECURITY MODEM data transfer device. We designed this modem for special users who are involved
1MRS119000 Plug-in Modem. Operator s manual
1MRS119000 Plug-in Modem Operator s manual 1MRS 750577-MUM EN Issued 98-06-02 Version A Checked MKa Approved OV 1MRS119000 Plug-in Modem Data subject to change without notice Contents 1.0 General... 4
UNIVERSAL POWER-LINE CARRIER SYSTEM TYPE OPU-1
UNIVERSAL POWER-LINE CARRIER SYSTEM TYPE OPU-1 WHOLE BAND QAM MODEM MBPU Rev. 0 - July 2011 DIMAT Antonio Machado,78-80 08840 Viladecans, Barcelona-Spain Tel.: +34 933 490 700 Fax: +34 933 492 258 Mail
Industrial Modem Designed for unattended sites
Industrial Modem Designed for unattended sites Designed to survive harsh environmental conditions for unattended operation, such as remote monitoring. Dual Watchdog Timers which can restart the modem if
Vector F336E/2LL MODEM USER'S MANUAL
Vector F336E/2LL MODEM USER'S MANUAL CONTENTS CHAPTER 1 INTRODUCTION Features----------------------------------------------------------------1 Package Contents-----------------------------------------------------1
Chapter 11 V.25 bis Autodialer
Chapter 11 V.25 bis Autodialer GENERAL V.25 bis is an option that allows dialing functions to be controlled using synchronous data. Select V.25 bis through the appropriate &M command in the AT command
SWITCHED TELEPHONE NETWORK LEASED LINE
Distribué par : Contact : [email protected] Tél : 0326824929 Fax : 0326851908 Siège social : 2 rue René Laennec 51500 Taissy France www.hvssystem.com MTi 133-1 V34 33 600 b/s INDUSTRIAL MODEM SWITCHED
You have accessed an older version of a Paradyne product document.
You have accessed an older version of a Paradyne product document. Paradyne is no longer a subsidiary of AT&T. Any reference to AT&T Paradyne is amended to read Paradyne Corporation. Paradyne COMSPHERE
HOW TO USE YOUR INTELE-MODEM
HOW TO USE YOUR INTELE-MODEM 305-008800 Ultratec, Inc. 450 Science Drive Madison, WI 53711 (608) 238-5400 (Voice/TTY) Fax: (608) 238-3008 Email: [email protected] www.ultratec.com First Edition October
V.25 bis Autodialer (External Modem Only)
V.25 bis allows dialing functions to be controlled using synchronous data. You select V.25 bis through the appropriate &M command. Note The modem must be configured as V.25 SDLC ASCII NRZ for use with
Quectel Cellular Engine
Cellular Engine GSM UART Port Application Notes GSM_UART_AN_V1.01 Document Title GSM UART Port Application Notes Version 1.01 Date 2009-11-16 Status Document Control ID Release GSM_UART_AN_V1.01 General
DAVICOM Semiconductor, Inc. DM562AP. Integrated Data/Fax/Voice/Speakerphone Modem. Operation Manual & AT Command Set
Connectivity Beyond Limits DAVICOM Semiconductor, Inc. DM562AP Operation Manual & AT Command Set Contents Chapter 1: Introduction Introduction Modem Package The Data/Fax/Voice/Speakerphone External Modem
LS-101 LAN to Serial Device server. User s Manual
LS-101 LAN to Serial Device server User s Manual Revision History Revision No Date Author Remarks 0.1 August 29, 2001 IDC Initial document INTRODUCTION Overview Almost all instruments and most industrial
Fax Service Class 1 and Fax Service Class 1.0. Developer s Guide
Fax Service Class 1 and Fax Service Class 1.0 Developer s Guide Fax Class 1 and Class 1.0 Developer s Guide PN S000262C, Rev. C 11/01/07 Copyright 2002-7 by Multi-Tech Systems, Inc. This publication may
Date Rev. Details Author
Jtech engineering ltd J - Te c h E n g i n e e ring, L t d. 11080 Bond Boulevard Delta BC V4E 1M7 Canada Tel: 604 543 6272 Fax: 604 543 6476 http://www.jtecheng.com AUTODIALER USER S MANUAL REVISION HISTORY
FaxFinder V.34 Fax Server. Configuration Guide for Inter-Operation with Altigen AltiServ Phone Systems
FaxFinder V.34 Fax Server Configuration Guide for Inter-Operation with Altigen AltiServ Phone Systems FaxFinder Configuration Guide Inter-Operation with Altigen AltiServ Phone Systems PN S000418C, Version
Technical Note #14. Phone Modem Device Support. GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home
1 of 7 GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home GE Power Management Control System Description Software Hardware Operation Product Support Operator Interfaces F A Q s App
Leased Line Support for Cisco 2600/3600 Series Analog Modems
Leased Line Support for Cisco 2600/3600 Series Analog Modems This feature adds one modem AT command (AT&L) and two AT registers to be added to the modemcap for the appropriate leased lines. Several new
Global Monitoring + Support
Use HyperTerminal to access your Global Monitoring Units View and edit configuration settings View live data Download recorded data for use in Excel and other applications HyperTerminal is one of many
TDW-33 TD-36, TD-36 485 TR-36, TR-36B
AT Commands Reference Guide 6618-3202 TDW-33 TD-36, TD-36 485 TR-36, TR-36B Westermo Teleindustri AB 4 3 2 1 4 3 2 1 Industrial Telephone Modem www.westermo.com Introduction This document describes the
COMSPHERE 6700 SERIES NETWORK MANAGEMENT SYSTEM
COMSPHERE 6700 SERIES NETWORK MANAGEMENT SYSTEM SECURITY MANAGER FEATURE SUPPLEMENT Document No. 6700-A2-GB41-30 February 1998 Copyright 1998 Paradyne Corporation. All rights reserved. Printed in U.S.A.
SETTING UP A REMOTE MODEM CONNECTION Application Note 27
SETTING UP A REMOTE MODEM CONNECTION Application Note 27 with WeatherLink for Windows Serial Version Only INTRODUCTION This document provides guidelines on how to set up a remote modem connection. This
INTRODUCTION 3 XYZ EXAMPLE 3 CONNECTING THE FAXFINDER TO THE IP OFFICE SWITCH 4 CONFIGURING THE FAXFINDER FOR INTER-OPERATION -- THE XYZ EXAMPLE 4
FaxFinder V.34 Fax Server Reference Guide for Inter-Operation with Avaya IP Office Contents INTRODUCTION 3 XYZ EXAMPLE 3 CONNECTING THE FAXFINDER TO THE IP OFFICE SWITCH 4 CONFIGURING THE FAXFINDER FOR
Using the Teridian 73M2901CE in 4-Wire and Leased Line Applications
A Maxim Integrated Products Brand 7M90CE V. bis Single Chip Modem APPLICATION NOTE AN_90CE_0 February 009 Introduction Using the Teridian 7M90CE in -Wire and Leased Line Applications The Teridian 7M90
Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0
Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0 Copyright, 1999-2007 Virtual Integrated Design, All rights reserved. 1 Contents: 1. The Main Window. 2. The Port Setup Window. 3.
73M1866B/73M1966B FXOCTL Application User Guide November 2, 2009 Rev. 4.1 UG_1x66B_009
Simplifying System Integration TM 73M1866B/73M1966B FXOCTL Application User Guide November 2, 2009 Rev. 4.1 73M1866B/73M1966B FXOCTL Application User Guide 2009 Teridian Semiconductor Corporation. All
Accessing Diagnostics using a Dialup Modem
Purpose This application note is meant to guide a user through the setup and use of a dial-up modem to retrieve diagnostics data from a remote master. Equipment Used This application note was written specifically
Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI
Technical Manual For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI Caller ID.com WHOZZ CALLING? POS 2 Caller ID Monitoring Unit Technical Manual For use with Caller ID signaling
Reference Guide for Inter-Operation with Avaya IP Office INTRODUCTION 3 XYZ EXAMPLE 3 CONNECTING THE FAXFINDER TO THE IP OFFICE SWITCH 4
FaxFinder V.34 Fax Server Reference Guide for Inter-Operation with Avaya IP Office Contents INTRODUCTION 3 XYZ EXAMPLE 3 CONNECTING THE FAXFINDER TO THE IP OFFICE SWITCH 4 CONFIGURING THE FAXFINDER FOR
MultiModem ZBA. Quick Start Guide. MT9234ZBA-Series MT9234ZBA MT9234ZBA-V
MultiModem ZBA MT9234ZBA-Series MT9234ZBA MT9234ZBA-V Quick Start Guide MultiModem ZBA Quick Start Guide MT9234ZBA & MT9234ZBA-V 82100201L Rev. B Copyright This publication may not be reproduced, in whole
300/75,1200, 2400bps Asynchronous Bell103/212 - CCITT V.22, V.22bis QUAM in 2400bps, DPSK in 1200bps, FSK in 0-300bps
The Performance Champions USER GUIDE Technical Specifications... Data Rates: Compatibility: Modulation: Operation: Command Set: Transmit Level: Receive Sensitivity Dropout Level: Non-Volatile Memory: Power:
Application Note 2. Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP.
Application Note 2 Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP. Reverse Telnet or Serial Terminal Server MultiTX feature UK Support March 2014 1 Contents
Getting Started with IntelleView POS Administrator Software
Getting Started with IntelleView POS Administrator Software Administrator s Guide for Software Version 1.2 About this Guide This administrator s guide explains how to start using your IntelleView POS (IntelleView)
CallFinder. Model CF220 DID Adapter Quick Start Guide
CallFinder Model CF220 DID Adapter Quick Start Guide CallFinder Model CF220 DID Enabler Quick Start Guide P/N 82000160, Revision A Copyright 2004 by Multi-Tech Systems, Inc. All rights reserved. This publication
RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP
RouteFinder SOHO SOHO Security Appliance EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP Quick Start Guide RouteFinder RF825 Series Quick Start Guide RouteFinder SOHO Security Appliance
APPLICATION NOTE # Using Sage SMOS for VoIP Testing, IP Phone to IP Phone TABLE OF CONTENTS
Product: 930A L3 Communications Test Set 935AT Communications Test Set APPLICATION NOTE # Using Sage SMOS for VoIP Testing, IP Phone to IP Phone TABLE OF CONTENTS Introduction... 2 Configuring 935AT #1
PC Program User s Guide (01.01.05) 1. Connecting the PC. 2. Installation and Start-up. 3. Programming
Work Off-Line Set up a new database or modify a previously saved database (without being connected to the telephone system). This helps minimize on-site programming time. Work On-Line (connected directly
Connect to telephone. Connect to wall jack
AD350-SE Multi-Function Auto Dialer Installation Install the AD350 SE Multi Function Auto Dialer as shown in the below diagram. The AD350 SE is only work on standard analog phones. Do not install the dialer
Installation Guide. Reference Manual
TM Digi International Inc. 11001 Bren Road Minnetonka, MN 55343 (800) 344-4273 (612) 912-3444 Digi International GmbH Domkloster 1 50667 Köln Germany +49 221 920520 Digi International Asia Pte Ltd 13-06
How To Set Up A Modbus Cda On A Pc Or Maca (Powerline) With A Powerline (Powergen) And A Powergen (Powerbee) (Powernet) (Operating System) (Control Microsci
Firmware Loader User Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support: 888-226-6876
WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide
WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide Version 2.1, 4/2010 Disclaimer While every effort has been made to ensure that the information in this guide is accurate
Installation and Programming Manual
Manual Installation and Programming Manual This Manual describes the Industrial Modem, its uses and set up. It also describes the use of the configuration software. Effective: 31 July, 2001 Niobrara Research
Single channel data transceiver module WIZ2-434
Single channel data transceiver module WIZ2-434 Available models: WIZ2-434-RS: data input by RS232 (±12V) logic, 9-15V supply WIZ2-434-RSB: same as above, but in a plastic shell. The WIZ2-434-x modules
GW400 VoIP Gateway. User s Guide
GW400 VoIP Gateway User s Guide P/N: 956YD30001 Copyright 2006. All Rights Reserved. Document Version: 1.0 All trademarks and trade names are the properties of their respective owners. i Table of Contents
To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:
PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,
V.90 HAM PCI 56k Modem User Manual
V.90 HAM PCI 56k Modem User Manual This handbook is protected by copyright. It must not be copied, reproduced, translated or transmitted in electronic media, in whole or in part. Accuracy of the information
Configuring the 930A for Common PBX Metallic Signaling Interfaces
Product: 930A Communications Test Set APPLICATION NOTE # Configuring the 930A for Common PBX Metallic Signaling Interfaces TABLE OF CONTENTS Introduction...1 Primer...1 LOOP START...2 General...2 Trunk
BLUETOOTH SERIAL PORT PROFILE. iwrap APPLICATION NOTE
BLUETOOTH SERIAL PORT PROFILE iwrap APPLICATION NOTE Thursday, 19 April 2012 Version 1.2 Copyright 2000-2012 Bluegiga Technologies All rights reserved. Bluegiga Technologies assumes no responsibility for
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version
Standalone Voice/IP Gateway Model MVP200 H.323 Mode Quick Start Guide
Voice / Fax over IP Networks Standalone Voice/IP Gateway Model MVP200 H.323 Mode Quick Start Guide Quick Start Guide 82098177 Revision C MultiVOIP 200 (Model MVP200) This publication may not be reproduced,
FaxFinder. V.34 Fax Server. Configuration Guide for Inter-Operation with Panasonic TDA Phone Systems
FaxFinder V.34 Fax Server Configuration Guide for Inter-Operation with Panasonic TDA Phone Systems FaxFinder Configuration Guide Inter-Operation with Panasonic TDA Phone Systems PN S000398C, Version C
AA9604 Auto Attendant
AA9604 Auto Attendant Operation Manual 10AA96V4M.2.13.EN1 DSG, DSG logo, AA9604, VL880, VL880L, IM1200, IM2400, IL1000 and IL5000 are trademarks of DSG Technology. Windows and Outlook Express are trademarks
MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual
MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual Version: 1.0.1 Dec. 2005 Table of Contents I. Introduction 2 II. Operations 2 II.1. Theory of Operation 2 II.2. Configuration (PC-PC
SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual
SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual Version 1.0 - January 20, 2015 CHANGE HISTORY Version Date Description of Changes 1.0 January 20, 2015 Initial Publication
PollCat III. Pollable Call Accounting Terminal. User's Guide
WTI Part Number: 12374 Rev. F PollCat III Pollable Call Accounting Terminal User's Guide 5 Sterling Irvine California 92618 (949) 586-9950 Toll Free: 1-800-854-7226 Fax: (949) 583-9514 http://www.wti.com
Solution-16 Operators Manual ISSUE 1.60
Solution-16 Operators Manual ISSUE 1.60 !"#$%&"'()*+ Operators Manual Copyright 2002 by, SYDNEY, AUSTRALIA Document Part Number MA880O DOCUMENT ISSUE 1.60 Printed 22 March 2002 This documentation is provided
1 Getting Started. Before you can connect to a network
1 Getting Started This chapter contains the information you need to install either the Apple Remote Access Client or Apple Remote Access Personal Server version of Apple Remote Access 3.0. Use Apple Remote
CC Family of Data Collectors
CC Family of s Timely. Accurate. Complete. These are the characteristics you expect from CDR (Call Detail Recording) data generated by a call accounting system. CC data collectors* complement these characteristics
LLM-336. User Guide Issue 1.5 July 2008. Copyright 2008 MuLogic B.V. Olivier van Noortstraat 4 3124 LA Schiedam, The Netherlands
LLM-336 VOICE-BAND LEASED LINE MODEM (HARDWARE REVISION 2) User Guide Issue 1.5 July 2008 Copyright 2008 MuLogic B.V. Olivier van Noortstraat 4 3124 LA Schiedam, The Netherlands LLM 336 Leased Line Modem
This topic describes dial peers and their applications.
Dial Peers What is Dial Peer? This topic describes dial peers and their applications. What is a Dial Peer? A dial peer is an addressable call endpoint. Dial peers establish logical connections, called
Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES
Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM COMMUNICATIONS WITH AN OCTOPUS. Article # 072297-1 Last reviewed: 03/25/98 Keywords: Serial Port, Modem, Polling, AquaWeb, Node Not Responding
Modbus Communications for PanelView Terminals
User Guide Modbus Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the Modbus versions of the PanelView terminals. This document
FaxFinder. V.34 Fax Server. Configuration Guide for Inter-Operation between FaxFinder Model FF110 and 3Com NBX PBX Systems
FaxFinder V.34 Fax Server Configuration Guide for Inter-Operation between FaxFinder Model FF110 and 3Com NBX PBX Systems FaxFinder Configuration Guide Inter-Operation with 3Com NBX PBX Systems PN S000427B,
Traditional Telephony
Traditional Telephony Basic Components of a Telephony Network This topic introduces the components of traditional telephony networks. Basic Components of a Telephony Network 3 A number of components must
Telecommunications Switching Systems (TC-485) PRACTICAL WORKBOOK FOR ACADEMIC SESSION 2011 TELECOMMUNICATIONS SWITCHING SYSTEMS (TC-485) FOR BE (TC)
PRACTICAL WORKBOOK FOR ACADEMIC SESSION 2011 TELECOMMUNICATIONS SWITCHING SYSTEMS (TC-485) FOR BE (TC) Department of Electronic Engineering NED University of Engineering and Technology, Karachi LABORATORY
OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC. www.signalcrafters.com
OWNERS MANUAL Status Monitor for Windows 95, 98, ME, NT 4, 2000 & XP SIGNALCRAFTERS TECH, INC. www.signalcrafters.com 57 Eagle Rock Avenue, East Hanover, NJ 07936 Tel: 973-781-0880 or 800-523-5815 Fax:
Table of Contents GETTING STARTED... 3. Enter Password Dialog...3 Using Online Help...3 System Configuration Menu...4
Table of Contents DV2000 Configuration - Service Release 3.0 GETTING STARTED... 3 Enter Password Dialog...3 Using Online Help...3 System Configuration Menu...4 SYSTEM CONFIGURATION OVERVIEW... 5 Using
Compatible with All FXS Ports of Digium Asterisk VoIP PBX
X100P.com s STOC-FX World s First Professional Grade VoIP FXS to FXO Converter Compatible with All FXS Ports of Digium Asterisk VoIP PBX Copyright (c) 2006 by X100P.com All rights reserved including the
RTU-COM with GSM. User Notes and Short Form AT Commond Survey
1 RTU-COM with GSM User Notes and Short Form AT Commond Survey V. 1.00 / Feb 2006 / Doc 40143 2 1. Introduction This document is a guide for using GSM communication and GSM data accounts, and changing
Quectel Cellular Engine
Cellular Engine GPRS Startup User Guide GPRS_Startup_UGD_V1.01 Document Title GPRS Startup User Guide Version 1.01 Date 2009-11-16 Status Document Control ID Release GPRS_Startup_UGD_V1.01 General Notes
Channelized E1 and Channelized T1 Setup Commands
Channelized E1 and Channelized T1 Setup Commands This chapter describes the function and displays the syntax for channelized E1 and channelized T1 setup commands. For more information about defaults and
X 1 2 - D I A L U P. X12 (HIPAA) Dial-up Transmission System. Document Version 1.3 2013
X 1 2 - D X12 (HIPAA) Dial-up Transmission System Document Version 1.3 2013 I A L U P Table of Contents General... 3 Version and Release... 3 Purpose & Scope... 3 High Level Design... 4 Communications
Business Communications Manager ATA 2 User Guide
Business Communications Manager ATA 2 User Guide 2001 Nortel Networks P0941629 Issue 02 Contents About Business Communications Manager ATA 25 What does ATA 2 do? 5 Feature List 7 Alternate Line 7 Call
Meridian Digital Telephones and Options
Nortel Knowledge Network Meridian Digital Telephones and Options M2006 M2008/M2008HF M2616 M2216ACD M2016S Secure Set Quick Reference Guide Enterprise Solutions Documentation Introducing your Meridian
LOW COST GSM MODEM. Description. Part Number
Dual Band 900 / 1800 MHz Fax, SMS and Data Integral SIM Card holder Siemens TC-35i GSM Engine Rugged Extruded Aluminium Enclosure Compact Form Factor 86 x 54 x 25mm RS232 Interface with Auto baud rate
3Com U.S. Robotics. 56K Professional Message Modem. User s Guide
3Com U.S. Robotics 56K Professional Message Modem User s Guide This manual covers installation and operating instructions for the 3Com U.S. Robotics 56K Professional Message Modem IMPORTANT MESSAGE: In
Voice Mail. Objectives. When you finish this module, you will be able to:
Voice Mail 23 Objectives When you finish this module, you will be able to: Verify that the Embedded Voice Mail (EVM) application can record and play messages. Check the EVM health. Maintain the EVM system.
INTERNATIONAL TELECOMMUNICATION UNION. SERIES V: DATA COMMUNICATION OVER THE TELEPHONE NETWORK Interfaces and voiceband modems
INTERNATIONAL TELECOMMUNICATION UNION ITU-T V.24 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (02/2000) SERIES V: DATA COMMUNICATION OVER THE TELEPHONE NETWORK Interfaces and voiceband modems List of
Configuring Shared Line Appearances over Analog Trunks
61200796L1-29.1G March 2013 Configuration Guide Configuring Shared Line Appearances over Analog Trunks This configuration guide explains how to configure shared line appearances (SLAs) on AOS voice products
ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4
ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4 1 PURPOSE:... 1 2 CPM-4/CPM-2 COMPATIBILITY... 2 2.1 NETWORK CABLES... 2 2.2 FACTORY DEFAULT SETTINGS... 2 2.3 CHANGING THE RS-232 SERIAL PORT BAUD
LinkPlus Interface Guide
Avaya DEFINITY Communications System LinkPlus Interface Guide SpectraLink 6000 System SpectraLink 8000 System July 2008 Edition 1725-36130-001 Version E LinkPlus Interface Guide: Avaya DEFINITY Communications
Automatic Route Selection (ARS)
Automatic Route Selection (ARS) 19 Objectives When you finish this module, you will: Program numbers for external local calls. Use ARS to route a call. Understand how the system uses various CO dial tones.
SYMETRIX SOLUTIONS: TECH TIP February 2014
Crestron Symetrix Dialer Example Introduction This tech-tip describes how to control a Symetrix Radius AEC and telephony interface using a Crestron Pro2-style controller. A complete Symetrix Radius configuration
