1 V.25 bis allows dialing functions to be controlled using synchronous data. You select V.25 bis through the appropriate &M command. Note The modem must be configured as V.25 SDLC ASCII NRZ for use with an AS4 IBM computer (&M5). SOFTWARE GUIDELINES An indicator enclosed in less than/greater than signs represents a specific character in the appropriate character set, ASCII or EBCDIC. <sp> - space Each response below is considered an individual message by V.25 bis conventions. For example, a dial command with intermediate call progress enabled (BISYNC mode ASCII/EBCDIC character set) is: From computer To computer <sy><sy><stx>crn<sp>(25)555-24<etx> <sy><sy><stx>val<etb> V.25 bis commands can be in one of these data formats: ASYNC BISYNC SDLC NRZ SDLC NRZI in ASCII or EBCDIC Access these formats using: &M Asynchronous dial/asynchronous data &M Asynchronous dial/synchronous data &M2 Dials stored number when DTR off/on transition is detected/sync data &M3 Manual dial/sync data &M4 V.25 bis dialer/bisync protocol/sync data (ASCII) &M5 V.25 bis dialer/sdlc protocol/sync data (NRZ) &M6 V.25 bis async dial/sync data &M7 V.25 bis async dial/async data Motorola 336 BPS Fax Modem 53
2 &M8 V.25 bis dialer w/bisync protocol/sync data (EBCDIC) &M9 V.25 bis dialer w/sdlc protocol/sync data (EBCDIC) (NRZ) &MV.25 bis dialer w/sdlc protocol/sync data (ASCII) (NRZI) &MV.25 bis dialer w/sdlc protocol/sync data (EBCDIC) (NRZI) Separator fields depend on the data format. for ASYNC {sep} = command <CR> BISYNC {sep} = <sy><sy><stx> command <etx> SDLC {sep} = <Flags><Addr><ctl> command <FCS> where: <sy> = 6 hexadecimal <stx> = 2 hex <etx> = 3 hex <etb> = 7 hex <Flag> = 7E hex <Addr> = FF hex <ctl> = 3 hex (last frame), 3 hex (not last frame) <FCS> = Frame Check Sequence <CR> = Carriage Return 54 Motorola 336 BPS Fax Modem
3 DIAL PARAMETERS The parameters used in autodialing are listed below. The memory available for dialing can hold up to 4 characters. If you insert spaces or other parameters not listed, like as dashes, those characters are not counted. Character Function through 9 DTMF and pulse digit * and # DTMF digit : Wait for dial tone W Wait for 2nd type of dial tone > Pause for second = Pause for 3 seconds < Pause for programmed delay time P Pulse dialing T Tone dialing & Flash (go on hook) for <Insert equation here> second ; PARM separator Space, dash, parenthesis, Characters inserted for readability only period Motorola 336 BPS Fax Modem 55
4 V.25 BIS DIALER COMMANDS Sync Command Description CIC Connect incoming call command CRN nn...n Dial command (nn...n = number to be dialed) - 9 * # : W > = < P T & ; Space, dash, parenthesis, period CRR n CRS a DIC PRK PRL a;b PRN a;nn...n DTMF and pulse digit DTMF digit Wait for dial tone Wait for second type of dial tone Pause for second Pause for 3 seconds Pause for programmed delay time Pulse dial Tone dial Flash (go on hook) for /2 second Parameter separator Characters used for clarity Redial the last number a maximum of n times Dial stored number command (a = address) Disregard incoming call command Save current option settings Link number at address a with address b Program number command (nn...n = number to be dialed, a = address) PRO xxx;yy;;... Program options command (xxx = register address, yy = option count) PRP n Restores current option settings to the factory defaults in default bank n (-9) RLL Request list of linked numbers command RLN Request list of stored numbers command RLO xxx;yy Request list of stored options command (xxx = register address, yy = option count) RLV Request list of version information command 56 Motorola 336 BPS Fax Modem
5 RESPONSE MESSAGES Response Message Meaning CFIAB Call failure - answer back tone but no connection CFIDT Call failure - no dial tone CFIET Call failure - reorder or busy CFILD Call failure - link list complete CFINS Call failure - number not stored CFINT Call failure - no answer back tone, no ringback CFIRT Call failure - timeout occurred 336 bps 288 bps 264 bps 24 bps 26 bps 92 bps 68 bps 44 bps 2 bps 96 bps 72 bps 48 bps 24 bps 2 bps INC INVCU INVMS INVPS INVPV VAL Intermediate call progress - connection made at 336 Intermediate call progress - connection made at 288 Intermediate call progress - connection made at 264 Intermediate call progress - connection made at 24 Intermediate call progress - connection made at 26 Intermediate call progress - connection made at 92 Intermediate call progress - connection made at 68 Intermediate call progress - connection made at 44 Intermediate call progress - connection made at 2 Intermediate call progress - connection made at 96 Intermediate call progress - connection made at 72 Intermediate call progress - connection made at 48 Intermediate call progress - connection made at 24 Intermediate call progress - connection made at 2 Incoming ring detected Invalid command - command unknown Invalid command - message syntax error Invalid command - parameter syntax error Invalid command - parameter value error Valid command received Motorola 336 BPS Fax Modem 57
6 OPTIONS You can change the options for the V.25 bis autodialer using the PRO command or listed using the RLO command. Settings without options are permissive, 2-wire dial-up. Option Definition Settings Default 2: Intermediate call progress messages - Disable 3: Blind dial - Disable 7: Long space disconnect - Disable 5: Primary transmit / receive rate 7: 2 bps 8: 24 bps 34: 48 bps 35: 96 bps uncoded 36: 96 bps 46: 72 bps 47: 2, bps 48: 4,4 bps 49: 6,8 bps 5: 9,2 bps 5: 2,6 bps 52: 24, bps 53: 26,4 bps 54: 28,8 bps 55: 3,2 bps 56: 33,6 bps 55: Transmit clock - Internal - External 2 - Receive (slave) 63: Autoanswer - Disable (answer after to 255 rings) 64: Line current disconnect - Off - Short (8 ms) 2 - Long (9 ms) 76: Speaker control - Off - On 4 - On until CD 6 - Off when dialing 77: Speaker volume - Low - Medium 2 - High 54 (288 bps) Motorola 336 BPS Fax Modem
7 Option Definition Settings Default 85: Constant carrier RTS/CTS delay to 25 ms (in increments of ms) 87: DTR dropout timer DTR must turn off for this length of time to be recognized. to 255 in ms increments 89: Pause in dial string - Invalid to 255 seconds 9: Carriage return character ASCII or EBCDIC character range 9: Line feed character ASCII or EBCDIC character range 92: Guard tone = None = 55 Hz 2 = 8 Hz 93: Carrier detect delay - Off; to 255 in increments of ms 94: Loss of carrier disconnect - Off to 255 in ms increments 95: DTR dial address - Stored telephone number address to dial on DTR off-to-on transition 96: DTR dial - Disable 98: Call timeout - Off -255 sec 3: Signal quality retrain - Disable - Send training sequence on poor quality : Modulation mode : Automode : V.2 2: B3 5: V.22 6: V.22 bis 7: V.27 ter 9: V.29 2: V.32 bis 3: V.34 5 (5 ms) 2 3 dec dec ASCII; 37 dec EB- CDIC 6 (6 ms) 4 (.4 sec) 3 sec Motorola 336 BPS Fax Modem 59
8 Option Definition Settings Default 2 V.34 Select Threshold : Low : Medium 2: High 3 V.34 Asymmetric bit rates : Disabled : Enabled 93: Bilateral loop - If enabled and a test is commanded, bilateral loop is defined as follows: - Disabled d Test Commanded Bilateral Loop Loop Loop 2 Loop 2 Loop Loop 3 Loop 4 Loop 4 Loop 3 Loop definitions are per CCITT V : Computer commanded remote digital loopback 95: Computer commanded local analog loopback - Disable - Disable 96: Remote commanded test - Disable 97: Test timer - Until DTR drops TTT - to 255 sec 6 Motorola 336 BPS Fax Modem
Chapter 11 V.25 bis Autodialer
Chapter 11 V.25 bis Autodialer GENERAL V.25 bis is an option that allows dialing functions to be controlled using synchronous data. Select V.25 bis through the appropriate &M command in the AT command
More informationLow Speed Modems for Dial and Leased Circuits 2400E-2 (Stand Alone) 2400R-2 (Rack Mount) 2400E-4 (Stand Alone) 2400R-4 (Rack Mount)
Low Speed Modems for Dial and Leased Circuits 2400E-2 (Stand Alone) 2400R-2 (Rack Mount) 2400E-4 (Stand Alone) 2400R-4 (Rack Mount) QUALITY COMMUNICATIONS PRODUCTS Made in the U.S.A. 11-1010-002 INTRODUCTION
More informationVector F336E/2LL MODEM USER'S MANUAL
Vector F336E/2LL MODEM USER'S MANUAL CONTENTS CHAPTER 1 INTRODUCTION Features----------------------------------------------------------------1 Package Contents-----------------------------------------------------1
More informationYou have accessed an older version of a Paradyne product document.
You have accessed an older version of a Paradyne product document. Paradyne is no longer a subsidiary of AT&T. Any reference to AT&T Paradyne is amended to read Paradyne Corporation. Paradyne COMSPHERE
More informationConfiguration Guide for Ascom Communications Server, Remote Management Package
Configuration Guide for Ascom Communications Server, Remote Management Package Introduction This document outlines the necessary steps and guidelines to configure the Ascom Communications Server, Remote
More informationApplied Data Communication Lecture 14
Applied Data Communication Lecture 14 Character oriented Data Link Character-oriented data link control Asynchronous Synchronous Kristjan Sillmann reaalajasüsteemide õppetool TTÜ automaatikainstituut character-oriented
More informationConnect to telephone. Connect to wall jack
AD350-SE Multi-Function Auto Dialer Installation Install the AD350 SE Multi Function Auto Dialer as shown in the below diagram. The AD350 SE is only work on standard analog phones. Do not install the dialer
More informationFAX/DATA MODEM USER'S MANUAL
FAX/DATA MODEM USER'S MANUAL Notice: Hayes is a trademark of Microcomputer Products Inc. Publication Number : ASK9705 Table of Contens i - FCC/DOC REQUIREMENTS i.1 FCC General Information i.2 FCC Notice
More informationDate Rev. Details Author
Jtech engineering ltd J - Te c h E n g i n e e ring, L t d. 11080 Bond Boulevard Delta BC V4E 1M7 Canada Tel: 604 543 6272 Fax: 604 543 6476 http://www.jtecheng.com AUTODIALER USER S MANUAL REVISION HISTORY
More information1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.
SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS WINLOAD MODEM SETUP The modem setup is a very important step in the connection process. If the modem setup is not properly completed communication between
More informationSystem Requirements. Hiro H50113
1 Hiro H50113 System Requirements Hiro H50113 Computer with Pentium 200 MMX or higher processor. Windows 2000, Windows XP Home / Professional, XP Professional x64 Edition, Vista 32 / 64 Families, Windows
More informationDial-Up / Leased-Line Modem. User Manual. AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) 5019-1 Manual Rev A + - DLM CTS RTS DTR DSR
AGM Electronics, Inc Dial-Up / Leased-Line Modem, Series ( ) 5019-1 Manual Rev A User Manual + - CD CTS RTS DTR. DSR RI RX TX PHONE LINE DLM Dial-Up / Leased-Line Modem Dial-Up / Leased-Line Modem CONTENTS
More informationPCM-3600 PC/104 Fax/Modem Module
PCM-3600 PC/104 Fax/Modem Module Copyright Notice This document is copyrighted, 1996, by AAEON Technology Inc. All rights are reserved. AAEON Technology Inc. reserves the right to make improvements to
More informationAutomatic Telephone Dialer TD-101(W)
Automatic Telephone Dialer TD-101(W) The TD-101 is an automatic dialing device which can transmit prerecorded information via the telephone line. The dialer can send two different 10 second voice messages
More informationIndustrial Modem. Designed for unattended sites
Industrial Modem Designed for unattended sites Designed to survive harsh environmental conditions for unattended operation, such as remote monitoring. Dual Watchdog Timers which can restart the modem if
More informationAccessing Diagnostics using a Dialup Modem
Purpose This application note is meant to guide a user through the setup and use of a dial-up modem to retrieve diagnostics data from a remote master. Equipment Used This application note was written specifically
More informationSWITCHED TELEPHONE NETWORK LEASED LINE
Distribué par : Contact : hvssystem@hvssystem.com Tél : 0326824929 Fax : 0326851908 Siège social : 2 rue René Laennec 51500 Taissy France www.hvssystem.com MTi 133-1 V34 33 600 b/s INDUSTRIAL MODEM SWITCHED
More informationIndustrial Modem Designed for unattended sites
Industrial Modem Designed for unattended sites Designed to survive harsh environmental conditions for unattended operation, such as remote monitoring. Dual Watchdog Timers which can restart the modem if
More informationINTERNATIONAL TELECOMMUNICATION UNION
INTERNATIONAL TELECOMMUNICATION UNION )454 6 TER TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU $!4! #/--5.)#!4)/. /6%2 4(% 4%,%0(/.%.%47/2+ ")43 0%2 3%#/.$ $50,%8 -/$%- 53).' 4(% %#(/ #!.#%,,!4)/. 4%#(.)15%
More information73M1866B/73M1966B FXOCTL Application User Guide November 2, 2009 Rev. 4.1 UG_1x66B_009
Simplifying System Integration TM 73M1866B/73M1966B FXOCTL Application User Guide November 2, 2009 Rev. 4.1 73M1866B/73M1966B FXOCTL Application User Guide 2009 Teridian Semiconductor Corporation. All
More informationProcess Control and Automation using Modbus Protocol
Process Control and Automation using Modbus Protocol Modbus is the fundamental network protocol used in most industrial applications today. It is universal, open and an easy to use protocol. Modbus has
More informationOne Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com. Using TSM-100AL on Leased Lines
AN8 APPLICATION NOTE One Technology Way P.O. Box 90 Norwood, MA 0090, U.S.A. Tel: 78.9.700 Fax: 78.. www.analog.com Using TSM00AL on Leased Lines by Ajai Gambhir and Erik Hulsmans INTRODUCTION This application
More information1MRS119000 Plug-in Modem. Operator s manual
1MRS119000 Plug-in Modem Operator s manual 1MRS 750577-MUM EN Issued 98-06-02 Version A Checked MKa Approved OV 1MRS119000 Plug-in Modem Data subject to change without notice Contents 1.0 General... 4
More informationZypcom Application Note
Zypcom Application Note Product: Z34-SX, Z34-RX, Z34-SE, Z34-RE, Z32t-SX, Z32t-SE, Z32t-RX, Z32b-SX, Z32b-SE, Z32b-RE and Z32b-RX Application: Leased Line Operation with Synchronous Data Synchronous leased
More informationAPPLICATION NOTE # Using Sage SMOS for VoIP Testing, IP Phone to IP Phone TABLE OF CONTENTS
Product: 930A L3 Communications Test Set 935AT Communications Test Set APPLICATION NOTE # Using Sage SMOS for VoIP Testing, IP Phone to IP Phone TABLE OF CONTENTS Introduction... 2 Configuring 935AT #1
More informationTechnical Note #14. Phone Modem Device Support. GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home
1 of 7 GE ED&C Home Search ED&C GE ED&C Power Management Home GE ED&C PMCS Home GE Power Management Control System Description Software Hardware Operation Product Support Operator Interfaces F A Q s App
More information18.04.2005 version 3.1. Security modem with USB port user guide
18.04.2005 version 3.1 Security modem with USB port user guide Introduction Congratulations on selecting the new SECURITY MODEM data transfer device. We designed this modem for special users who are involved
More informationG.A.L. HANDS FREE EMERGENCY TELEPHONE MODEL GAL-6400
I. GENERAL G.A.L. HANDS FREE EMERGENCY TELEPHONE MODEL GAL-6400 The GAL-6400 Hands Free Emergency Telephone permits a pre-programmed number to be dialed when the "push to call" button is depressed on the
More informationTAP Interface Specifications
TAP Interface Specifications This Document is for those who want to develop their own paging control software or add an interface for the WaveWare v9 Series Paging Encoder to their existing software applications.
More informationPROPERTY MANAGEMENT SYSTEM
PROPERTY MANAGEMENT SYSTEM COMMUNICATION INTERFACE SPECIFICATION NEC America, Inc. NDA-305-00 Revision.0 June, 998 Stock # 24727 LIABILITY DISCLAIMER NEC America reserves the right to change the specifications,
More informationChannelized E1 and Channelized T1 Setup Commands
Channelized E1 and Channelized T1 Setup Commands This chapter describes the function and displays the syntax for channelized E1 and channelized T1 setup commands. For more information about defaults and
More informationINTERNATIONAL TELECOMMUNICATION UNION
INTERNATIONAL TELECOMMUNICATION UNION )454 6 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU $!4! #/--5.)#!4)/. /6%2 4(% 4%,%0(/.%.%47/2+ ")43 0%2 3%#/.$ $50,%8 -/$%- 34!.$!2$):%$ &/2 53% ). 4(% '%.%2!,
More informationMeridian Digital Telephones and Options
Nortel Knowledge Network Meridian Digital Telephones and Options M2006 M2008/M2008HF M2616 M2216ACD M2016S Secure Set Quick Reference Guide Enterprise Solutions Documentation Introducing your Meridian
More informationHow To Use A 1232 On A 1236 On A Computer Or A Cell Phone
12-36-1000 Autodialler and Relay Telephone Interface 1.0 INTRODUCTION 12-36-1000 I/O Telephone Interface with AutoDialer The 12-36-1000 is a autodialer and telephone interface that can be used autonomously
More informationCONCEPT1 RS232 COMMUNICATION
Concept 1 RS-232 Communication Communication with Concept 1 via RS-232 is done with simple ASCII Commands and Replies. The port settings are 19200Baud, 8bits, no parity and 1 stop bit. The physical connection
More informationThis chapter discusses Synchronous Data Link Control (SDLC) protocols that you can configure on a BANDIT device s ports. See the following sections:
encor! enetworks TM Version A, September 2010 2010 Encore Networks, Inc. All rights reserved. SDLC Protocol Configuration This chapter discusses Synchronous Data Link Control (SDLC) protocols that you
More informationCOMSPHERE 6700 SERIES NETWORK MANAGEMENT SYSTEM
COMSPHERE 6700 SERIES NETWORK MANAGEMENT SYSTEM SECURITY MANAGER FEATURE SUPPLEMENT Document No. 6700-A2-GB41-30 February 1998 Copyright 1998 Paradyne Corporation. All rights reserved. Printed in U.S.A.
More informationD7024 Fire Alarm Control Panels Software Version V2.06
D7024 Fire Alarm Control Panels Software Version V2.06 Program Record Sheet Account Information: Account: Date: Name: Address: Panel Phone #: Contact Phone #: Contact Person: Comments: Panel Location:
More informationI-modem Command Reference
U.S. Robotics I-modem Command Reference page i The material contained in this manual is for information purposes only and is subject to change without notice. No part of this document may be reproduced,
More informationTelecommunications systems (Part 1)
School of Business Eastern Illinois University Telecommunications systems (Part 1) (Week 11, Thursday 11/02/2006) Abdou Illia, Fall 2006 Learning Objectives 2 Describe and compare types of connection to
More informationUNIVERSAL POWER-LINE CARRIER SYSTEM TYPE OPU-1
UNIVERSAL POWER-LINE CARRIER SYSTEM TYPE OPU-1 WHOLE BAND QAM MODEM MBPU Rev. 0 - July 2011 DIMAT Antonio Machado,78-80 08840 Viladecans, Barcelona-Spain Tel.: +34 933 490 700 Fax: +34 933 492 258 Mail
More informationHOW TO USE YOUR INTELE-MODEM
HOW TO USE YOUR INTELE-MODEM 305-008800 Ultratec, Inc. 450 Science Drive Madison, WI 53711 (608) 238-5400 (Voice/TTY) Fax: (608) 238-3008 Email: service@ultratec.com www.ultratec.com First Edition October
More informationURL encoding uses hex code prefixed by %. Quoted Printable encoding uses hex code prefixed by =.
ASCII = American National Standard Code for Information Interchange ANSI X3.4 1986 (R1997) (PDF), ANSI INCITS 4 1986 (R1997) (Printed Edition) Coded Character Set 7 Bit American National Standard Code
More informationQuectel Cellular Engine
Cellular Engine GSM UART Port Application Notes GSM_UART_AN_V1.01 Document Title GSM UART Port Application Notes Version 1.01 Date 2009-11-16 Status Document Control ID Release GSM_UART_AN_V1.01 General
More informationQuick Reference Guide For Partner ACS R5 System Programming
System Programming From extension 10 or 11 (Any MLS display phone) dial Feature 00, then press the Left Intercom button 2 times to enter System Programming. The numbers in parentheses after the program
More informationTELOCATOR ALPHANUMERIC PROTOCOL (TAP)
TELOCATOR ALPHANUMERIC PROTOCOL (TAP) Version 1.8 February 4, 1997 TABLE OF CONTENTS 1.0 Introduction...1 2.0 TAP Operating Environment...1 3.0 Recommended Sequence Of Call Delivery From An Entry Device...2
More informationIBM Emulation Mode Printer Commands
IBM Emulation Mode Printer Commands Section 3 This section provides a detailed description of IBM emulation mode commands you can use with your printer. Control Codes Control codes are one-character printer
More informationSolution-16 Operators Manual ISSUE 1.60
Solution-16 Operators Manual ISSUE 1.60 !"#$%&"'()*+ Operators Manual Copyright 2002 by, SYDNEY, AUSTRALIA Document Part Number MA880O DOCUMENT ISSUE 1.60 Printed 22 March 2002 This documentation is provided
More informationFirmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
More informationIP PBX system USER MANUAL. ver. 2.01.02
IP PBX system USER MANUAL ver. 2.01.02 Platan Prima IP PBX is a product manufactured by: PLATAN Sp. z o.o. sp.k., 81-855 Sopot, ul. Platanowa 2, Poland tel. +48 58 555 88 00, fax +48 58 555 88 01 e-mail:
More informationICP-CC488 ICP-CC488 EN. Control Panel. Quick Reference Guide
ICP-CC488 EN Quick Reference Guide ICP-CC488 Control Panel ICP-CC488 Quick Reference Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security
More informationManufactures of: All. Dallas Delta Corporation Pty.Ltd. Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: 613 93877388 Fax: 613 93873128
Dallas Delta Corporation Pty.Ltd. 102 Albert St. East Brunswick, 3057 Vic. Tel: 613 93877388 Fax: 613 93873128 Email: sales@dallasdelta.com.au www.dallasdelta.com.au LP GUARD DOORSTATION MK II G UARD Doorstation
More informationSingle Line Telephone User Guide
Record of Revision Release Date Version Supersedes Description March 2008 Initial Release Initial Release Copyright 2006 We reserves the right to make changes in specifications at any time without notice.
More informationSUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual
SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual Version 1.0 - January 20, 2015 CHANGE HISTORY Version Date Description of Changes 1.0 January 20, 2015 Initial Publication
More informationOperating Instructions. Telephone System tiptel 1/8 fax clip tiptel 2/8 clip. (Release 2) tiptel
Operating Instructions (UK) Telephone System tiptel 1/8 fax clip tiptel 2/8 clip (Release 2) tiptel Table of Contents Connection of 8 extensions..........3 Connection of 7 extensions and 1 door intercom................4
More informationVirtual Integrated Design Getting started with RS232 Hex Com Tool v6.0
Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0 Copyright, 1999-2007 Virtual Integrated Design, All rights reserved. 1 Contents: 1. The Main Window. 2. The Port Setup Window. 3.
More informationTelecommunications Switching Systems (TC-485) PRACTICAL WORKBOOK FOR ACADEMIC SESSION 2011 TELECOMMUNICATIONS SWITCHING SYSTEMS (TC-485) FOR BE (TC)
PRACTICAL WORKBOOK FOR ACADEMIC SESSION 2011 TELECOMMUNICATIONS SWITCHING SYSTEMS (TC-485) FOR BE (TC) Department of Electronic Engineering NED University of Engineering and Technology, Karachi LABORATORY
More informationAT&T MERLIN COMMUNICATIONS SYSTEM USER S GUIDE MODELS 206, 410 AND 820 WITH FEATURE PACKAGE 2
AT&T MERLIN COMMUNICATIONS SYSTEM USER S GUIDE MODELS 206, 410 AND 820 WITH FEATURE PACKAGE 2 Table of Contents Page Page Available Features Key to Symbols Placing and Answering Calls Line Buttons and
More informationUsing the Teridian 73M2901CE in 4-Wire and Leased Line Applications
A Maxim Integrated Products Brand 7M90CE V. bis Single Chip Modem APPLICATION NOTE AN_90CE_0 February 009 Introduction Using the Teridian 7M90CE in -Wire and Leased Line Applications The Teridian 7M90
More informationLeased Line Support for Cisco 2600/3600 Series Analog Modems
Leased Line Support for Cisco 2600/3600 Series Analog Modems This feature adds one modem AT command (AT&L) and two AT registers to be added to the modemcap for the appropriate leased lines. Several new
More informationNokia and Nokia Connecting People are registered trademarks of Nokia Corporation
Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation Nokia E70 Configuring connection settings Nokia E70 Configuring connection settings Legal Notice Copyright Nokia 2006. All
More informationTechnical Support Bulletin Nr.18 Modbus Tips
Technical Support Bulletin Nr.18 Modbus Tips Contents! Definitions! Implemented commands! Examples of commands or frames! Calculating the logical area! Reading a signed variable! Example of commands supported
More informationGlobal Monitoring + Support
Use HyperTerminal to access your Global Monitoring Units View and edit configuration settings View live data Download recorded data for use in Excel and other applications HyperTerminal is one of many
More informationAuto Attendant & Voice Mail System Installation and Programming Manual. Version 7.1 April 2005
Auto Attendant & Voice Mail System Installation and Programming Manual Version 7.1 April 2005 Table of Contents Table of Contents 1 Introduction... 1-1 1.1. Manual Audience and Contents... 1-1 2 General
More informationIP Link Device Interface Ethernet Communication Sheet
This document provides additional assistance with wiring your Extron IP Link enabled product to your device. Different components may require a different wiring scheme than those listed below. For complete
More informationNokia E61i Configuring connection settings
Nokia E61i Configuring connection settings Nokia E61i Configuring connection settings Legal Notice Copyright Nokia 2007. All rights reserved. Reproduction, transfer, distribution or storage of part or
More informationXi2000 Series Configuration Guide
U.S. Default Settings Sequence Reset Scanner Xi2000 Series Configuration Guide Auto-Sense Mode ON UPC-A Convert to EAN-13 OFF UPC-E Lead Zero ON Save Changes POS-X, Inc. 2130 Grant St. Bellingham, WA 98225
More informationM-AXS Telephone Control Unit Multi Line Least Cost Routing / Store and Forward / Call Back Dialer
GLOBENET M-AXS Telephone Control Unit Multi Line Least Cost Routing / Store and Forward / Call Back Dialer Programming Manual Issue 2.02 July, 2001 1487 A7-3375 North Service Road, Burlington, Ontario,
More informationASCII Code. Numerous codes were invented, including Émile Baudot's code (known as Baudot
ASCII Code Data coding Morse code was the first code used for long-distance communication. Samuel F.B. Morse invented it in 1844. This code is made up of dots and dashes (a sort of binary code). It was
More informationAASTRA 9110 User Guide
AASTRA 9110 User Guide Key Descriptions Redial Save Flash Mute Handset Ringer Switch Set Indicator Light Volume Bar Dial Pad Handsfree/Mute 7 Memory Keys Making and Answering Calls Making a call With your
More informationVoice Processing Features
Voice Processing Features CONTENTS PAGE 1. Introduction........................................................ 4-3 A. Voice Processing Applications....................................... 4-3 B. Time Slot
More informationThis chapter describes unpacking and installing your modem.
PCM-3601 USER MENU Unpacking and Installation Chapter 1 This chapter describes unpacking and installing your modem. 1.1 Feature FDSP (Full duplex speakerphone) - Acoustic and line echo cancellation - Microphone
More informationMotorola C12A. Digital Cordless Telephone with Digital Answering Machine. For C1211A, C1212A, C1213A and C1214A
Digital Cordless Telephone with Digital Answering Machine Motorola C12A For C1211A, C1212A, C1213A and C1214A Warning: Charge the handset for 24 hours before use. Welcome... to your new Motorola C12A Digital
More informationAtlas Event Logging Explanation
1 of 10 8/30/2006 4:35 PM Atlas Event Logging Explanation Introduction The Atlas Event Log is used to log various message types at settable threshold levels. This section describes the entries that may
More informationMultiModem. AT Commands Reference Guide
MultiModem For MultiModem ZBA Series MultiModem IND MultiModem DID MultiModem ZPX Series MultiModem ZPX-ISA MultiModem ISI Series AT Commands Reference Guide Copyright and Technical Support AT Commands
More informationWA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide
WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide Version 2.1, 4/2010 Disclaimer While every effort has been made to ensure that the information in this guide is accurate
More informationMT5600BA/BL Series MT5600BA V.92 MT5600BA V.90 MT5600BL V.90. Data/Fax Modem User Guide
MT5600BA/BL Series MT5600BA V.92 MT5600BA V.90 MT5600BL V.90 Data/Fax Modem User Guide MultiModemII User Guide MT5600BA V.92, MT5600BA V.90, MT5600BL V.90 P/N S000276E Revision E 2002-2004 by Multi-Tech
More informationAA9604 Auto Attendant
AA9604 Auto Attendant Operation Manual 10AA96V4M.2.13.EN1 DSG, DSG logo, AA9604, VL880, VL880L, IM1200, IM2400, IL1000 and IL5000 are trademarks of DSG Technology. Windows and Outlook Express are trademarks
More informationOWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC. www.signalcrafters.com
OWNERS MANUAL Status Monitor for Windows 95, 98, ME, NT 4, 2000 & XP SIGNALCRAFTERS TECH, INC. www.signalcrafters.com 57 Eagle Rock Avenue, East Hanover, NJ 07936 Tel: 973-781-0880 or 800-523-5815 Fax:
More informationTCP/IP Network Connectivity and ION Meters
70072-0170-04 TECHNICAL NOTE 12/2007 TCP/IP Network Connectivity and ION Meters This technical note describes how PowerLogic ION8800, ION8600, ION7550 and ION7650 meters are able to interact with several
More informationTECHNICAL. Open Source PC Based Telecom Controller PB-100. Open Source PC to Phone Line Interface
TECHNICAL Practice TELECOM SOLUTIS FOR THE 21ST CENTURY PB-100 Open Source PC to Phone Line Interface December 26, 2001 Features Phone...715.386.8861 info@vikingelectronics.com Open Source PC Based Telecom
More informationBusiness Communications Manager Telephone Feature Card
Business Communications Manager Telephone Feature Card 2002 Nortel Networks P0993297 Issue 01 Buttons The Business Series Terminal (T-series) Feature button is a small globe icon. The M-series Feature
More informationConfiguring the ADTRAN ATLAS for a Rabbit-Hole Application
Configuring the ADTRAN ATLAS for a Rabbit-Hole Application Description: This configuration allows an ADTRAN ATLAS to convert PRI to FXS and pass ANI/DNIS information as DTMF digits toward a receiver in
More informationAdded and Changed Features for Installation Manual and Programming Tables Vol. 3
Digital Super Hybrid System KX-TD86CE KX-TD232CE Added and Changed Features for Installation Manual and Programming Tables Vol. 3 Please read this manual first and then the Installation Manual. In this
More informationHow To Send A Message From A Computer To A Computer (Iwea) On A Microsoft Macbook 2.5 (Isoa) To A Microsatellite 2.4 (Ios) On An Unix (Ise
1. PROTOCOL ASTRA COMMUNICATION PROTOCOL (via RS232C) Argentina specification (B0319G) 26 Oct 2004 METHOD TRANSMISSION CONTROL PROCEDURE BAUD RATE DATA BIT STOP BIT PARITY DATA COMMUNCATION ORDER CONNECTOR
More informationFundamentals of Telecommunications
Fundamentals of Telecommunications Professor of CIS Columbus, OH 43210 Jain@ACM.Org http://www.cis.ohio-state.edu/~jain/ 1 Overview Time Division Multiplexing T1, T3, DS1, E1 T1 Framing Echo Cancellation
More informationSYMETRIX SOLUTIONS: TECH TIP August 2015
String Output Modules The purpose of this document is to provide an understanding of operation and configuration of the two different String Output modules available within SymNet Composer. The two different
More information73M2901CE Programming the Imprecise Call Progress Monitor Filter
A Maxim Integrated Products Brand 73M2901CE Programming the Imprecise Call Progress Monitor Filter APPLICATION NOTE AN_2901CE_042 March 2009 Introduction The Teridian 73M2901CE integrated circuit modem
More informationConfiguring connection settings
Configuring connection settings Nokia E90 Communicator Configuring connection settings Nokia E90 Communicator Configuring connection settings Legal Notice Nokia, Nokia Connecting People, Eseries and E90
More informationTCR easy Plus Alarm. Operating Instructions
TCR easy Plus Alarm Operating Instructions Table of Contents General.....................................4 Installation...................................5 Putting into Operation............................5
More informationLLM-336. User Guide Issue 1.5 July 2008. Copyright 2008 MuLogic B.V. Olivier van Noortstraat 4 3124 LA Schiedam, The Netherlands
LLM-336 VOICE-BAND LEASED LINE MODEM (HARDWARE REVISION 2) User Guide Issue 1.5 July 2008 Copyright 2008 MuLogic B.V. Olivier van Noortstraat 4 3124 LA Schiedam, The Netherlands LLM 336 Leased Line Modem
More informationTELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE
TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE September 2004 Prepared by: Integrated Systems Division The Sutron Corporation 21300 Ridgetop Circle Sterling, VA 20166 Copyright 2004
More informationInstallation and Programming Manual
Manual Installation and Programming Manual This Manual describes the Industrial Modem, its uses and set up. It also describes the use of the configuration software. Effective: 31 July, 2001 Niobrara Research
More informationDSX Master Communications
DSX Access Systems, Inc. PC to Master Controller - Direct Connect Communications DSX Master Communications Communications between the Comm Server PC and the Master Controller can take several forms which
More informationRelease Date Version Supersedes Description. June 2006 Initial Release Initial Release
45p SLT User Guide Record of Revision Release Date Version Supersedes Description June 2006 Initial Release Initial Release Copyright XBLUE Networks, LLC 2006 XBLUE Networks reserves the right to make
More informationU-336R/RE. User s Guide. Version 1.0 (Mar. 1997) ZyXEL ACCESSING INTERNET & INTRANET
U-336R/RE User s Guide Version 1.0 (Mar. 1997) ZyXEL ACCESSING INTERNET & INTRANET ZyXEL Limited Warranty ZyXEL warrants to the original end user (purchaser) that this product is free from any defects
More informationAristel SLT70 OPERATION MANUAL 2.1 SLT70 LAYOUT...2 2.2 CHECK LIST...3 2.3 INSTALLATION NOTE...3
Aristel SLT70 OPERATION MANUAL 1 GENERAL DESCRIPTION... 1 2 TELEPHONE SPECIFICATION... 2 2.1 SLT70 LAYOUT...2 2.2 CHECK LIST...2 2.2 CHECK LIST...3 2.3 INSTALLATION NOTE...3 3 FACILITY OPERATION... 4 3.1
More informationProgramming and Using the Courier V.Everything Modem for Remote Operation of DDF6000
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version
More informationVOIP-211RS/210RS/220RS/440S. SIP VoIP Router. User s Guide
VOIP-211RS/210RS/220RS/440S SIP VoIP Router User s Guide Trademarks Contents are subject to revise without prior notice. All trademarks belong to their respective owners. FCC Warning This equipment has
More information