1 SAS enters the mainstream By the InfoStor staff Although adoption of Serial Attached SCSI (SAS) is still in the infancy stages, the next 12 months bode well for proponents of the relatively new disk drive/array interface. For example, in a recent InfoStor QuickVote reader poll, 27% of the respondents said SAS will account for the majority of their disk drive purchases over the next year, although Serial ATA (SATA) topped the list with 37% of the respondents, followed by Fibre Channel with 32%. Only 4% of the poll respondents cited the aging parallel SCSI interface (see figure). However, surveys of InfoStor s readers are skewed by the fact that almost half of our readers are in the channel (primarily VARs and systems/storage integrators), and the channel moves faster than end users in terms of adopting (or at least kicking the tires on) new technologies such as serial interfaces. Click here to enlarge image To get a more accurate view of the pace of adoption of serial interfaces such as SAS, consider market research predictions from firms such as Gartner and International Data Corp. (IDC). Yet even in those firms predictions, SAS is coming on surprisingly strong, mostly at the expense of its parallel SCSI predecessor. For example, Gartner predicts SAS disk drives will account for 16.4% of all multi-user drive shipments this year and will garner almost 45% of the overall market in 2009 (see figure on p. 18). IDC s disk-drive shipment projections underline the same general trend toward serial interfaces, but differ in the specifics. For example, IDC expects SAS to account for 15.7% of the enterprise drive category shipments this year, and almost 26% in 2009 (see figure on p. 18). However, regardless of which predictions prove to be more accurate, it s clear that SAS has hit the mainstream in a relatively short period of time. The basics
2 Unlike parallel transmission technology, which transmits data in multiple streams, serial interfaces send data in a single stream. As such, they are not tied to a particular clock speed and can send data faster. SAS, for example, has a theoretical maximum transfer rate of 3Gbps (in both directions), as does the current generation of SATA. The current generation of Fibre Channel has a maximum transfer rate of 4Gbps. SAS overcomes some of the inherent limitations of parallel SCSI, such as signal skew and crosstalk, signal termination restrictions, cable and connector reflection, lack of scalability and performance, and device addressability (theoretically, up to 128 devices with SAS, or more than 16,000 devices per domain with expanders, compared to only 15 devices with parallel SCSI). Although many of the advantages of SAS (versus parallel SCSI) relate to packaging issues that may be of more interest to OEMs and integrators (e.g., thinner cables, etc.), end users will be drawn to the speed advantages and what some think is SAS s crowning achievement: SAS enclosures can support both SAS and/or SATA disk drives. This capability gives users and integrators the ability to create tiered storage systems or domains that combine higher-performance SAS drives with higher-capacity (and lower-cost/ performance) SATA drives. Other benefits of SAS include dual-ported drives (also a feature of Fibre Channel drives), the use of expanders for adding external capacity, and a point- to-point connection architecture (vs. parallel SCSI s shared-bus architecture) for higher performance. In a point-to-point architecture, each device has a dedicated path to the controller, with full bandwidth on each connection. SAS also features multi-lane, or wide, connections so that, for example, an x4 (or 4x ) connection provides up to 24Gbps aggregate, bidirectional throughput. New products Market research firms predict a rosy future for SAS, but another way to gauge market momentum is by the number of product introductions. And there have been a slew of SAS products released recently. Here s a sampling of SAS products that went into production shipments over the last few months: Click here to enlarge image Accusys 64-bit ACS SAS-SAS RAID controller supports SATA native command queuing (NCQ) and SCSI tagged command queuing (TCQ), and has dual PCI-X connections, up to 16 SAS drive channels, a 533MHz RISC I/O processor, up to 4GB DDR2 cache memory, support for all RAID levels (and multiple RAID levels and stripe sizes in a single disk group), online disk group defragmentation and LUN capacity expansion, and support for Windows Virtual Disk Service (VDS) and Multi-Path I/O (MPIO). Adaptec is shipping five Unified Serial SAS/ SATA RAID controllers for PCIe systems. The low-profile cards are designed for entry-level to midrange servers and workstations. The controllers are available with four internal ports (model 3405), eight internal ports (model 3805), 12 internal ports (model 31205), 16 internal ports (model 31605), or eight external ports with dual-path fail-over (model 3085).
3 Click here to enlarge image Features include Performance: Hot Space (RAID-5EE) spreads the hot-spare disk space across the array and increases performance by using the spare spindle; Data protection: Dual-drive failure protection (RAID 6) ensures the array can survive two disk failures without losing data; and Management: Users can manage data backups by taking point-in-time snapshots (via an optional Snapshot Backup feature) and copying them to tape or disk without taking arrays offline. A hotspare slot can be designated in the disk cabinet, so after replacing a failed drive the array will reconstruct to its original configuration. Pricing for the controllers, which come with up to 256MB of cache and support for RAID arrays of up to 512TB, ranges from $390 to $995. Click here to enlarge image Advanced Industrial Computer s (AIC) Xtore division is shipping the XD 2000 RAID arrays, which support SAS/SATA drives and can be configured with dual 4Gbps Fibre Channel or 3Gbps x4 SAS host channels per blade. The XD 2000 includes RAID 50 Interleave (RAID 50i) for higher availability. RAID 50i creates multiple RAID-5 drive strata within a single RAID set across single or multiple enclosures within a storage domain, and protects against multiple drive failures. Xtore officials claim that RAID 50i does not have the overhead and performance penalties sometimes associated with RAID 6. The XD 2000 subsystems also support RAID 0, 1, 5, and 6. Other features include dual active controller blades, logical volume virtualized storage, and support for up to 16 drives in a 3U enclosure. Arena Maxtronic recently began shipments of the JanusRAID2 SS-6651E and SS-6652E RAID storage systems. The SS-6651E has a 4Gbps Fibre Channel host interface and the SS-6652E has a 3Gbps four-lane (x4) host interface that provides 12Gbps of aggregate throughput. Both subsystems support all RAID levels, including the company s NRAID, as well as JBOD configurations. Logical disks and volumes have independently configured stripe sizes, support online initialization, and sequential prioritized rebuilding. Up to three RAID alteration tasks can be performed online without bringing a subsystem offline. (Tasks include disk group expansion, defragmentation, logical disk expansion, RAID level migration, and stripe size migration.) Reliability features include disk scrubbing, disk self test, and disk cloning.
4 Atto Technology entered the SAS adapter market with the ExpressSAS R348 (internal) and R380 (external) RAID adapters. The company also launched a SAS Advantage channel program for VARs and integrators targeting high-throughput environments such as digital video. Atto officials attribute the adapters performance in part to the company s Advanced Data Streaming (ADS) technology and the use of Intel s 800MHz IOP348 I/O processors for PCIe hosts. The company claims a throughput rate of up to 903MBps in a RAID-5 configuration with 256KB transfers across inch SAS drives, or 979MBps with 4MB transfers. Like all SAS adapters, the ExpressSAS cards support both 3Gbps SAS and SATA drives. In addition to supporting virtually all standard RAID levels, the adapters support Atto s DV RAID, which is designed to accelerate performance in streaming media applications such as high-definition (HD) digital video editing. The cards feature a native (as opposed to bridged) PCIe implementation with x8 PCIe-to-SAS/SATA interfaces and come in a low-profile form factor. The R348 has user-configurable internal port options with x4 Mini-SAS connectors (eight internal, or four internal and four external), and the R380 has eight external ports (two x4 Mini-SAS connectors). Other features of the ExpressSAS adapters include support for up to 32 physical drives and 128 logical drives, 256MB of ECC SDRAM, and support for Windows, Linux, and Mac OS X platforms. MSRP for the adapters is $1,095. Ciprico s RAIDCore RC5000 line of SAS/SATA controllers for Windows and Linux platforms leverage software-based RAID. Compatible with PCI-X and PCI Express hosts, the controllers are currently available in 8-port configurations, with 12- and 16-port versions due next month. The company claims more than 1.1GBps throughput with 16 SATA drives. Users can create virtual arrays of up to 32 drives. Eight-port controllers supporting RAID 5 are priced at $299, and RAID-0/1/10 versions are priced at $219. Dot Hill s 2730 Turbo RAID array, which is targeted primarily at OEMs and integrators, is up to 40% faster than the model 2730 due to a new processor. The company claims 1,154MBps sustained throughput and transfer rates of more than 124,000 I/Os per second. Based on Dot Hill s R/Evolution architecture and SimulCache technology (which leverages dual RAID controllers instead of conventional cache mirroring), the disk array has 12 drives per enclosure (expandable to 56) in any mix of SATA or SAS drives. The 2U systems come with four Fibre Channel host interfaces, with SAS and iscsi external interfaces due later this year. The 2730 also supports RAID-6 (dual-parity RAID). Adding to its line of Fibre Channel (FC) and FC/SAS controllers, Emulex has introduced its IOC 500S-a pure SAS ASIC designed for OEMs. The IOC 500S simultaneously supports target and initiator modes, is based on Intel s IOP34x processors, and is compatible with Emulex s Service Level Interface (SLI), which allows system builders to leverage driver-compatible designs across different applications and protocols. Other features of the IOC 500S include BlockGuard technology for data integrity, scalability up to 512 targets per chip, and eight SAS/SATA ports. Enhance Technology s most recent SAS subsystems include the eight-drive RS8 SS, 16-drive RS16 SS, and eight-drive T8 SS. Common features include support for virtually all RAID levels (including RAID 6), SAS/SATA interfaces, and dual SAS ports. The company claims performance of up to 500MBps for the T8 SS, 550MBps for the RS8 SS, and more than 850MBps for the RS16 SS. The subsystems include Qsan controllers and can be configured with SAS drives from Hitachi (UltraStar), Maxtor (Atlas 10k/15k), or Seagate (Cheetah). Excel Meridian Data recently began shipping the SecurStor Astra ES SAS/SATA, Astra SA SATA, and Astra SA iscsi subsystems. The 2U Astra ES supports SAS/SATA drives, active-active fail-over/fail-back RAID
5 controllers, up to four 12-bay JBOD modules for scalability up to 45TB, single or dual controllers, SAS or Fibre Channel host interfaces, virtually all RAID levels (RAID 0, 1, 1E, 3, 5, 6, 10, 50, and 60), and Multi-Path I/O (MPIO) software. Hitachi GST s flagship SAS disk drives are the 3.5-inch Ultrastar 15K300 and 2.5-inch Ultrastar C10K147. The 15K300 comes in capacities up to 300GB and has a disk rotation speed of 15,000rpm and a 16MB cache buffer. In addition to SAS, the Ultrastar 15K300 is available with 320MBps Ultra320 SCSI or 4Gbps Fibre Channel interfaces. The Ultrastar C10K147 small-form-factor (SFF) drive has a rotation rate of 10,000rpm, a 16MB buffer, and a capacity of up to 147GB. IBM is shipping a variety of LTO-4 tape drives and libraries with SAS as an optional interface (see IBM ships LTO-4, broadens encryption, p. 1). Over the last couple months, Infortrend has begun volume shipments of a number of SAS subsystems. The EonStor A08S-G2130 and A12S-G2130 are SAS-to-SATA subsystems with eight or twelve drives, respectively, for PCI-X systems. Built on the company s ASIC400 chip and a 600MHz PowerPC FL CPU, the 2U subsystems support all RAID levels and include two wide SAS ports for up to 24Gbps aggregate throughput. The EonStor S16F-R1430 subsystem supports SAS/SATA drives and 4Gbps Fibre Channel host connections. Features include dual RAID controllers with four Fibre Channel connections per controller, all RAID levels, sustained throughput of more than 800MBps in RAID-5 writes, multi-lane SAS expansion channels for connecting to the company s JBOD arrays, and support for up to 64 drives with one RAID system and three JBOD arrays. The EonStor S16S-J1000 is a SAS- to-sas JBOD array available in single- or dual-controller configurations, with two SAS ports per controller. By cascading units, the ES S16S-J1000 can support up to 64 SAS or SATA drives. Infortrend is also shipping the EonStor A16S-G2130 RAID subsystems, which have SAS host connections and SATA drive connections. The 3U SAS-SATA array includes 16 drive bays, two SAS channels (with 12Gbps per channel), and support for all RAID levels. Intel s Storage Server SSR212MC2 is a quad-core system with Xeon 5300 series CPUs. The rack-mount server can be configured in a number of ways, including as a NAS box, as a SAN array, or as an application server with direct- attached storage. The storage server can also be configured with a choice of SAS and/or SATA drives and can support 14 drives for capacities ranging from 3.6TB with 300GB SAS drives to 9TB using 750GB SATA drives. Intel s storage server is based on a 2U chassis from Xyratex. Pricing starts at $2,800 without a RAID controller, or $3,600 with Intel s SRCSAS144e RAID controller. JMR is shipping a number of SAS subsystems, some with PCIe host connections. The company s 3U Storage Server comes with dual Xeon processors and up to inch SAS/SATA drives (for 16TB of capacity with SATA drives or 4.8TB with 15,000rpm SAS drives). The subsystems support PCI-X and PCIe expansions slots and come with a SAS JBOD or RAID controller. SATA JBOD or RAID controllers are optional. JMR is also shipping a 3U, 16-bay SAS-SATA JBOD expander unit with dual 4x SAS ports and up to 16 SAS or SATA drive connections.
6 In a twist on traditional host connections, JMR s PeSAN JBOD or RAID subsystems have a PCIe port for host connection and 16 SAS/SATA drive ports. Features are similar to the company s Storage Servers: 3U enclosure with 16TB of capacity with SATA drives or 4.8TB with SAS drives. Users and integrators can scale capacity by adding PCIe-based PeSAN External Switch units, PCIe x8 Extender Storage Systems, or PCIe internal-toexternal adapters. The latest members of LSI s SAS product lineup are the 4-port MegaRAID 8204 and 8-port MegaRAID 8208 adapters. Designed for low-end to midrange servers and workstations, the low-profile 8200 series adapters support SAS or SATA drives, RAID 5, and PCI-X or PCI-Express host buses. MSRP for the 4-port 8205 adapter is $229, and $315 for the 8-port MegaRAID In April, LSI announced that it had shipped more than two million SAS IC devices. NEC Corp. of America recently announced a wide range disk arrays that can be configured with SAS and/or SATA drives for scalability beyond 1PB. Promise Technology recently began shipping SAS products in its VTrak line of storage subsystems and SuperTrak line of RAID HBAs. The 2U, 12-drive VTrak E-Class disk arrays support SAS/SATA drives, 4Gbps Fibre Channel host connectivity (model E310f) or 3Gbps SAS host connectivity (model E310s), dual controllers, hardware-accelerated RAID 5/6, and the PCIe bus, and are based on Intel s IOP341 processor and XScale architecture. Promise s SAS RAID controllers on its SuperTrak EX series of HBAs are based on Intel s IOP348 processors and can be configured for internal or external connectivity. Seagate s 2.5-inch Savvio 15K SAS disk drive, which Hewlett-Packard uses in its ProLiant servers, has a rotation rate of 15,000rpm and a capacity of 36GB or 73GB. Versus 3.5-inch, 15,000rpm drives, Seagate claims the 2.5-inch Savvio 15K is 70% smaller and 1.12 pounds lighter, and uses 30% less power. Seagate specs the drives at a mean time between failure (MTBF) rate of 1.6 million hours. Xyratex has added to its line of nearline data storage systems with the F5404E FC-to-SAS/SATA RAID array. The F5404E has a fault-tolerant architecture with two RAID controllers per chassis and host-based dynamic multi-pathing that maintains continuous access to application data. Additional features include four 4Gbps Fibre Channel host connections, 3Gbps SAS/SATA drive connectivity, RAID 6, and snapshots. The system scales to 36TB in less than 4U of rack space. In addition, major server vendors such as Dell, Hewlett-Packard, and IBM are shipping servers with directattached SAS/ SATA drives. The only notable holdouts so far in the trend toward SAS are EMC and Network Appliance, which have not yet announced support for SAS. InfoStor June, 2007 Author(s) : InfoStor Staff
SAN TECHNICAL - DETAILS/ SPECIFICATIONS
SAN TECHNICAL - DETAILS/ SPECIFICATIONS Technical Details / Specifications for 25 -TB Usable capacity SAN Solution Item 1) SAN STORAGE HARDWARE : One No. S.N. Features Description Technical Compliance
Maximizing Server Storage Performance with PCI Express and Serial Attached SCSI. Article for InfoStor November 2003 Paul Griffith Adaptec, Inc.
Filename: SAS - PCI Express Bandwidth - Infostor v5.doc Maximizing Server Storage Performance with PCI Express and Serial Attached SCSI Article for InfoStor November 2003 Paul Griffith Adaptec, Inc. Server
Transitioning to 6Gb/s SAS (Serial-Attached SCSI) A Dell White Paper
Transitioning to 6Gb/s SAS (Serial-Attached SCSI) A Dell White Paper December 2009 THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES.
SAS & FC COMPARED THE R/EVOLUTION DIFFERENCE. white paper. SAS vs. FC
THE R/EVOLUTION DIFFERENCE white paper SAS vs. FC ª ª SAS & FC COMPARED white paper ª ª TABLE OF CONTENTS Introduction 3 SAS (Serial Attached SCSI ) - the New SCSI 3 Market Timing 3 SAS and FC Similarities
The Benefit of Migrating from 4Gb to 8Gb Fibre Channel
The Benefit of Migrating from 4Gb to 8Gb Fibre Channel Notices The information in this document is subject to change without notice. While every effort has been made to ensure that all information in this
Enterprise Disk Storage Subsystem Directions
White Paper Enterprise Disk Storage Subsystem Directions Steve Bohac and Andrew Chen, NetApp June 2009 WP-7074-0609 EXECUTIVE SUMMARY Significant changes are coming to enterprise disk technology and disk
DELL RAID PRIMER DELL PERC RAID CONTROLLERS. Joe H. Trickey III. Dell Storage RAID Product Marketing. John Seward. Dell Storage RAID Engineering
DELL RAID PRIMER DELL PERC RAID CONTROLLERS Joe H. Trickey III Dell Storage RAID Product Marketing John Seward Dell Storage RAID Engineering http://www.dell.com/content/topics/topic.aspx/global/products/pvaul/top
VTrak 15200 SATA RAID Storage System
Page 1 15-Drive Supports over 5 TB of reliable, low-cost, high performance storage 15200 Product Highlights First to deliver a full HW iscsi solution with SATA drives - Lower CPU utilization - Higher data
HP reference configuration for entry-level SAS Grid Manager solutions
HP reference configuration for entry-level SAS Grid Manager solutions Up to 864 simultaneous SAS jobs and more than 3 GB/s I/O throughput Technical white paper Table of contents Executive summary... 2
Post-production Video Editing Solution Guide with Microsoft SMB 3 File Serving AssuredSAN 4000
Post-production Video Editing Solution Guide with Microsoft SMB 3 File Serving AssuredSAN 4000 Dot Hill Systems introduction 1 INTRODUCTION Dot Hill Systems offers high performance network storage products
Oracle Database Deployments with EMC CLARiiON AX4 Storage Systems
Oracle Database Deployments with EMC CLARiiON AX4 Storage Systems Applied Technology Abstract This white paper investigates configuration and replication choices for Oracle Database deployment with EMC
Seagate Constellation/Barracuda* ES.2 SAS Hard Drives and Intel RAID SAS/SATA Adapters Powered by LSI MegaRAID*
Seagate Constellation/Barracuda* ES.2 SAS Hard Drives and Intel RAID SAS/SATA Adapters Powered by LSI MegaRAID* White Paper Ideal for Low-Cost Servers and Nearline Applications July 2009 Enterprise Platforms
PCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation
PCI Express Impact on Storage Architectures and Future Data Centers Ron Emerick, Oracle Corporation SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies
Agenda. Enterprise Application Performance Factors. Current form of Enterprise Applications. Factors to Application Performance.
Agenda Enterprise Performance Factors Overall Enterprise Performance Factors Best Practice for generic Enterprise Best Practice for 3-tiers Enterprise Hardware Load Balancer Basic Unix Tuning Performance
white paper A CASE FOR VIRTUAL RAID ADAPTERS Beyond Software RAID
white paper A CASE FOR VIRTUAL RAID ADAPTERS Beyond Software RAID Table of Contents 1. Abstract...3 2. Storage Configurations...4 3. RAID Implementation...4 4. Software RAID.4-5 5. Hardware RAID Adapters...6
Storage Synergies: Adaptec Series 5 Unified Serial Controllers and Seagate Barracuda ES.2 SAS Drives
Storage Synergies: Adaptec Series 5 Unified Serial Controllers and Seagate Barracuda ES.2 SAS Drives A new generation of storage controllers and disk drives is now available, optimal for a growing class
WHITEPAPER: Understanding Pillar Axiom Data Protection Options
WHITEPAPER: Understanding Pillar Axiom Data Protection Options Introduction This document gives an overview of the Pillar Data System Axiom RAID protection schemas. It does not delve into corner cases
PCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation
PCI Express Impact on Storage Architectures and Future Data Centers Ron Emerick, Oracle Corporation SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies
IOmark- VDI. Nimbus Data Gemini Test Report: VDI- 130906- a Test Report Date: 6, September 2013. www.iomark.org
IOmark- VDI Nimbus Data Gemini Test Report: VDI- 130906- a Test Copyright 2010-2013 Evaluator Group, Inc. All rights reserved. IOmark- VDI, IOmark- VDI, VDI- IOmark, and IOmark are trademarks of Evaluator
Using Multipathing Technology to Achieve a High Availability Solution
Using Multipathing Technology to Achieve a High Availability Solution Table of Contents Introduction...3 Multipathing Technology...3 Multipathing I/O Implementations...5 Storage Redundancy...5 Infortrend
The skinny on storage clusters
The skinny on storage clusters Storage clustering can mean different things based on the vendor and the architecture which the technology is built on, but the features or benefits are usually similar across
What is RAID--BASICS? Mylex RAID Primer. A simple guide to understanding RAID
What is RAID--BASICS? Mylex RAID Primer A simple guide to understanding RAID Let's look at a hard disk... Several platters stacked on top of each other with a little space in between. One to n platters
PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector
PCI Express 2.0 SATA III RAID Controller Card with Internal Mini-SAS SFF-8087 Connector StarTech ID: PEXSAT34SFF The PEXSAT34SFF PCI Express SATA Controller Card enables 4 AHCI SATA III connections to
Education. Servicing the IBM ServeRAID-8k Serial- Attached SCSI Controller. Study guide. XW5078 Release 1.00
Education Servicing the IBM ServeRAID-8k Serial- Attached SCSI Controller Study guide XW5078 Release 1.00 May 2006 Servicing the IBM ServeRAID-8k Serial- Attached SCSI (SAS) Controller Overview The ServeRAID
IBM ^ xseries ServeRAID Technology
IBM ^ xseries ServeRAID Technology Reliability through RAID technology Executive Summary: t long ago, business-critical computing on industry-standard platforms was unheard of. Proprietary systems were
6Gb/s MegaRAID SAS RAID Controllers
6Gb/s MegaRAID SAS RAID Controllers User Guide 41450-04, Rev. B 41450-04B Revision History Version and Date Description of Changes 41450-04, Rev. B, Updated the environmental conditions for the RAID controllers.
UCS M-Series Modular Servers
UCS M-Series Modular Servers The Next Wave of UCS Innovation Marian Klas Cisco Systems June 2015 Cisco UCS - Powering Applications at Every Scale Edge-Scale Computing Cloud-Scale Computing Seamlessly Extend
RocketRAID Product Guide
RocketRAID Product Guide Your Complete SAS and SATA RAID HBA Manufacturer Technologies, Inc. 8 Ports 12 Ports 4 Ports 16 Ports 2 Ports 24 Ports HighPoint TerabyteArchitecture www.hptesata.com H i g h P
How To Use An Hp Smart Array P212 (Sas) With A 1-Year Warranty On A 2 Terabyte Hard Drive (Sata) And A 1 Terabyte (Sasa) Hard Drive With A 2-Year License (S
Overview The HP Smart Array P212 is HP's entry level PCI Express (PCIe) Serial Attached SCSI (SAS) RAID controller. The low profile, half height card has 8 ports and utilizes DDR2-800 memory. The P212
Redundancy in enterprise storage networks using dual-domain SAS configurations
Redundancy in enterprise storage networks using dual-domain SAS configurations technology brief Abstract... 2 Introduction... 2 Why dual-domain SAS is important... 2 Single SAS domain... 3 Dual-domain
HUS-IPS-5100S(D)-E (v.4.2)
Honeywell s HUS-IPS-5100S(D)-E is a controller-based IP SAN unified storage appliance. Designed for centralized mass data storage, this IP SAN solution can be used with the high performance streaming server
Dell Microsoft Business Intelligence and Data Warehousing Reference Configuration Performance Results Phase III
White Paper Dell Microsoft Business Intelligence and Data Warehousing Reference Configuration Performance Results Phase III Performance of Microsoft SQL Server 2008 BI and D/W Solutions on Dell PowerEdge
N8103-149/150/151/160 RAID Controller. N8103-156 MegaRAID CacheCade. Feature Overview
N8103-149/150/151/160 RAID Controller N8103-156 MegaRAID CacheCade Feature Overview April 2012 Rev.1.0 NEC Corporation Contents 1 Introduction... 3 2 Types of RAID Controllers... 3 3 New Features of RAID
Post Production Video Editing Solution Guide with Apple Xsan File System AssuredSAN 4000
Post Production Video Editing Solution Guide with Apple Xsan File System AssuredSAN 4000 Dot Hill Systems introduction 1 INTRODUCTION Dot Hill Systems offers high performance network storage products that
Cisco Unified Computing System and EMC VNXe3300 Unified Storage System
Cisco Unified Computing System and EMC VNXe3300 Unified Storage System An Ideal Solution for SMB Server Consolidation White Paper January 2011, Revision 1.0 Contents Cisco UCS C250 M2 Extended-Memory Rack-Mount
DD670, DD860, and DD890 Hardware Overview
DD670, DD860, and DD890 Hardware Overview Data Domain, Inc. 2421 Mission College Boulevard, Santa Clara, CA 95054 866-WE-DDUPE; 408-980-4800 775-0186-0001 Revision A July 14, 2010 Copyright 2010 EMC Corporation.
As enterprise data requirements continue
Storage Introducing the Dell PERC 6 Family of SAS RAID ControlLers By Bhanu Prakash Dixit Sanjay Tiwari Kedar Vaze Joe H. Trickey III The Dell PowerEdge Expandable RAID Controller (PERC) 6 family of enterprise-class
PCI Express Impact on Storage Architectures. Ron Emerick, Sun Microsystems
PCI Express Impact on Storage Architectures Ron Emerick, Sun Microsystems SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies and individual members may
ServeRAID M5015 and M5014 SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide
ServeRAID M5015 and M5014 SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide The ServeRAID M5015 and ServeRAID M5014 SAS/SATA Controllers for IBM System x are the next-generation 6 Gbps SAS
Performance Report Modular RAID for PRIMERGY
Performance Report Modular RAID for PRIMERGY Version 1.1 March 2008 Pages 15 Abstract This technical documentation is designed for persons, who deal with the selection of RAID technologies and RAID controllers
Annex 1: Hardware and Software Details
Annex : Hardware and Software Details Hardware Equipment: The figure below highlights in more details the relation and connectivity between the Portal different environments. The number adjacent to each
Intel Solid- State Drive Data Center P3700 Series NVMe Hybrid Storage Performance
Intel Solid- State Drive Data Center P3700 Series NVMe Hybrid Storage Performance Hybrid Storage Performance Gains for IOPS and Bandwidth Utilizing Colfax Servers and Enmotus FuzeDrive Software NVMe Hybrid
WHITE PAPER. How To Build a SAN. The Essential Guide for Turning Your Windows Server Into Shared Storage on Your IP Network
WHITE PAPER How To Build a SAN The Essential Guide for Turning Your Windows Server Into Shared Storage on Your IP Network TABLE OF CONTENTS Introduction... 3 What is a SAN?... 4 Why iscsi Storage?... 4
Post-production Video Editing Solution Guide with Quantum StorNext File System AssuredSAN 4000
Post-production Video Editing Solution Guide with Quantum StorNext File System AssuredSAN 4000 Dot Hill Systems introduction 1 INTRODUCTION Dot Hill Systems offers high performance network storage products
Q & A From Hitachi Data Systems WebTech Presentation:
Q & A From Hitachi Data Systems WebTech Presentation: RAID Concepts 1. Is the chunk size the same for all Hitachi Data Systems storage systems, i.e., Adaptable Modular Systems, Network Storage Controller,
Building High-Performance iscsi SAN Configurations. An Alacritech and McDATA Technical Note
Building High-Performance iscsi SAN Configurations An Alacritech and McDATA Technical Note Building High-Performance iscsi SAN Configurations An Alacritech and McDATA Technical Note Internet SCSI (iscsi)
The HBAs tested in this report are the Brocade 825 and the Emulex LPe12002 and LPe12000.
Emulex HBA Product Evaluation Evaluation report prepared under contract with Emulex Corporation Introduction Emulex Corporation commissioned Demartek to evaluate its 8 Gbps Fibre Channel host bus adapters
How To Evaluate Netapp Ethernet Storage System For A Test Drive
Performance evaluation sponsored by NetApp, Inc. Introduction Ethernet storage is advancing towards a converged storage network, supporting the traditional NFS, CIFS and iscsi storage protocols and adding
1000-Channel IP System Architecture for DSS
Solution Blueprint Intel Core i5 Processor Intel Core i7 Processor Intel Xeon Processor Intel Digital Security Surveillance 1000-Channel IP System Architecture for DSS NUUO*, Qsan*, and Intel deliver a
Serial ATA and Serial Attached SCSI technologies
Serial ATA and Serial Attached SCSI technologies technology brief Abstract... 2 Introduction... 2 Serial architecture: the future of HDD technologies... 2 Parallel ATA technology... 2 Parallel SCSI...
Serial ATA technology
Serial ATA technology Technology brief, 4 th edition Introduction... 2 SATA devices and interoperability with SAS devices... 2 Initiators... 2 Expanders... 3 Targets and their recommended uses... 3 Entry
Cisco 7816-I5 Media Convergence Server
Cisco 7816-I5 Media Convergence Server Cisco Unified Communications Solutions unify voice, video, data, and mobile applications on fixed and mobile networks, enabling easy collaboration every time from
1. Specifiers may alternately wish to include this specification in the following sections:
GUIDE SPECIFICATION Seneca is a leading US designer and manufacturer of xvault security and surveillance solutions. The xvault product line combines our IP expertise and solution partnerships with certified
EDUCATION. PCI Express, InfiniBand and Storage Ron Emerick, Sun Microsystems Paul Millard, Xyratex Corporation
PCI Express, InfiniBand and Storage Ron Emerick, Sun Microsystems Paul Millard, Xyratex Corporation SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies
Certification: HP ATA Servers & Storage
HP ExpertONE Competency Model Certification: HP ATA Servers & Storage Overview Achieving an HP certification provides relevant skills that can lead to a fulfilling career in Information Technology. HP
F600Q 8Gb FC Storage Performance Report Date: 2012/10/30
F600Q 8Gb FC Storage Performance Report Date: 2012/10/30 Table of Content IO Feature Highlights Test Configurations Maximum IOPS & Best Throughput Maximum Sequential IOPS Test Configurations Random IO
UN 4013 V - Virtual Tape Libraries solutions update...
UN 4013 V - Virtual Tape Libraries solutions update... - a Unisys storage partner Key issues when considering virtual tape Connectivity is my platform supported by whom? (for Unisys environments, MCP,
Deploying Microsoft Exchange Server 2010 on the Hitachi Adaptable Modular Storage 2500
Deploying Microsoft Exchange Server 2010 on the Hitachi Adaptable Modular Storage 2500 Reference Architecture Guide By Patricia Brailey July 2010 Summary IT administrators need email solutions that provide
The safer, easier way to help you pass any IT exams. Exam : 000-115. Storage Sales V2. Title : Version : Demo 1 / 5
Exam : 000-115 Title : Storage Sales V2 Version : Demo 1 / 5 1.The IBM TS7680 ProtecTIER Deduplication Gateway for System z solution is designed to provide all of the following EXCEPT: A. ESCON attach
White Paper. Enhancing Storage Performance and Investment Protection Through RAID Controller Spanning
White Paper Enhancing Storage Performance and Investment Protection Through RAID Controller Spanning May 2005 Introduction It is no surprise that the rapid growth of data within enterprise networks is
Open-E Data Storage Software and Intel Modular Server a certified virtualization solution
Open-E Data Storage Software and Intel Modular Server a certified virtualization solution Contents 1. New challenges for SME IT environments 2. Open-E DSS V6 and Intel Modular Server: the ideal virtualization
QUESTIONS & ANSWERS. ItB tender 72-09: IT Equipment. Elections Project
QUESTIONS & ANSWERS ItB tender 72-09: IT Equipment. Elections Project In lot 1, position 1 - Server for Data Base 1. Q: You order Microsoft Windows Server 2008, 64 bit, Enterprise, License with 25 or more
Dell PowerVault MD Family. Modular storage. The Dell PowerVault MD storage family
Dell MD Family Modular storage The Dell MD storage family Dell MD Family Simplifying IT The MD Family simplifies IT by optimizing your data storage architecture and ensuring the availability of your data.
PCIe Over Cable Provides Greater Performance for Less Cost for High Performance Computing (HPC) Clusters. from One Stop Systems (OSS)
PCIe Over Cable Provides Greater Performance for Less Cost for High Performance Computing (HPC) Clusters from One Stop Systems (OSS) PCIe Over Cable PCIe provides greater performance 8 7 6 5 GBytes/s 4
White Paper June 2013. 12Gb/s SAS: Key Considerations For Your Next Storage Generation
White Paper June 2013 12Gb/s SAS: Key Considerations For Your Next Storage Generation 12Gb/s SAS: Key Considerations / Table of Contents Table of Contents Introduction...1 SAS Foundations...1 SAS Advances...
PCI Express and Storage. Ron Emerick, Sun Microsystems
Ron Emerick, Sun Microsystems SNIA Legal Notice The material contained in this tutorial is copyrighted by the SNIA. Member companies and individuals may use this material in presentations and literature
SMB Direct for SQL Server and Private Cloud
SMB Direct for SQL Server and Private Cloud Increased Performance, Higher Scalability and Extreme Resiliency June, 2014 Mellanox Overview Ticker: MLNX Leading provider of high-throughput, low-latency server
Optimizing Large Arrays with StoneFly Storage Concentrators
Optimizing Large Arrays with StoneFly Storage Concentrators All trademark names are the property of their respective companies. This publication contains opinions of which are subject to change from time
QuickSpecs. HP StorageWorks Modular Smart Array 500 G2. Overview
Overview 1. Display 5. Power Switch 2. Display Buttons 6. Status Indicators 3. Display Indicators 7. Redundant Controller Slot Blank 4. Modular Smart Array Controller 8. Drive Bay(s) 1. Power Supply/Blower
Serial ATA in Servers and Networked Storage
Serial ATA in Servers and Networked Storage Serial ATA (SATA) in Servers and Networked Storage Introduction Serial ATA (SATA) is a storage interface technology developed by a group of the industry s leading
QuickSpecs. What's New Boot from Tape. Models HP Smart Array P411 Controller
Overview The HP Smart Array P411 is HP's external connect only, PCI Express (PCIe) 2.0 Serial Attached SCSI (SAS) RAID controller for Integrity rack optimized servers. The low profile, half height card
SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION
SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION AFFORDABLE, RELIABLE, AND GREAT PRICES FOR EDUCATION Optimized Sun systems run Oracle and other leading operating and virtualization platforms with greater
MegaRAID 6Gb/s SAS RAID Controllers
MegaRAID 6Gb/s SAS RAID Controllers User Guide 41450-02, Revision D, June 2010 41450-02D Revision History Version and Date Description of Changes 41450-02 Rev. D, June 2010 Added the SAS 9260-16i, SAS
QuickSpecs. What's New Support for HP MSA 2040 Storage. Models. HP Smart Array P712m Controller. Overview
Overview The HP Smart Array P712m mezzanine card is the preferred high value solution for 6Gb/s Shared SAS Storage for the HP ProLiant BladeSystem servers. It is one of the highest performing controllers
Violin Memory Arrays With IBM System Storage SAN Volume Control
Technical White Paper Report Best Practices Guide: Violin Memory Arrays With IBM System Storage SAN Volume Control Implementation Best Practices and Performance Considerations Version 1.0 Abstract This
UK HQ RAID Chunk Size T F www.xyratex.com ISO 14001
RAID Chunk Size Notices The information in this document is subject to change without notice. While every effort has been made to ensure that all information in this document is accurate, Xyratex accepts
HP D3600 Disk Enclosure 4,000 Mailbox Resiliency Exchange 2013 Storage Solution
Technical white paper HP D3600 Disk Enclosure 4,000 Mailbox Resiliency Exchange 2013 Storage Solution Table of contents Overview... 2 Disclaimer... 2 Features of the tested solution... 2 HP D3600 Disk
27 22 00 Data Communications Hardware 27 22 16 Data Communications Storage and Backup 27 22 19 Data Communications Servers
Pivot3 has over 1200 customers across the globe that rely on purpose-built Pivot3 appliances for highcapacity video surveillance and high-iop virtual desktop environments. The company is the leading supplier
HP StorageWorks MSA2000
HP StorageWorks MSA2000 Best practices Table of contents About this document... 2 Intended audience... 2 Topics covered MSA2000 G1... 2 Hardware overview... 3 iscsi, Fibre Channel, or SAS... 4 Unified
PCI Express SATA III RAID Controller Card with Mini-SAS Connector (SFF-8087) - HyperDuo SSD Tiering
PCI Express SATA III RAID Controller Card with Mini-SAS Connector (SFF-8087) - HyperDuo SSD Tiering StarTech ID: PEXSAT34SFF The PEXSAT34SFF PCI Express 2.0 SATA Controller Card enables 4 AHCI SATA III
Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide
Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide Thank you for buying an Intel RAID Module. Your Intel RAID Module provides reliability,
SAN Conceptual and Design Basics
TECHNICAL NOTE VMware Infrastructure 3 SAN Conceptual and Design Basics VMware ESX Server can be used in conjunction with a SAN (storage area network), a specialized high speed network that connects computer
RAID technology and IBM TotalStorage NAS products
IBM TotalStorage Network Attached Storage October 2001 RAID technology and IBM TotalStorage NAS products By Janet Anglin and Chris Durham Storage Networking Architecture, SSG Page No.1 Contents 2 RAID
HP Direct-Connect External SAS Storage for HP BladeSystem Solutions Deployment Guide
HP Direct-Connect External SAS Storage for HP BladeSystem Solutions Deployment Guide This document provides device overview information, installation best practices and procedural overview, and illustrated
UNIFIED HYBRID STORAGE. Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment
DATASHEET TM NST6000 UNIFIED HYBRID STORAGE Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment UNIFIED The Nexsan NST6000 unified hybrid storage appliance is ideal for
Models Smart Array 6402A/128 Controller 3X-KZPEC-BF Smart Array 6404A/256 two 2 channel Controllers
Overview The SA6400A is a high-performance Ultra320, PCI-X array controller. It provides maximum performance, flexibility, and reliable data protection for HP OpenVMS AlphaServers through its unique modular
Intel RAID SSD Cache Controller RCS25ZB040
SOLUTION Brief Intel RAID SSD Cache Controller RCS25ZB040 When Faster Matters Cost-Effective Intelligent RAID with Embedded High Performance Flash Intel RAID SSD Cache Controller RCS25ZB040 When Faster
The BENEFITS of a Storage Bridge Bay Solution
White Paper The BENEFITS of a Storage Bridge Bay Solution What is a Storage Bridge Bay (SBB) solution? SBB is a workgroup made up of industry leaders in the server and storage technologies that essentially
Best Practices RAID Implementations for Snap Servers and JBOD Expansion
STORAGE SOLUTIONS WHITE PAPER Best Practices RAID Implementations for Snap Servers and JBOD Expansion Contents Introduction...1 Planning for the End Result...1 Availability Considerations...1 Drive Reliability...2
Factors rebuilding a degraded RAID
Whitepaper Abstract This whitepaper introduces the procedure rebuilding a degraded RAID. You will find information about RAID levels and their rebuild procedures; rebuild time and its dependent factors.
Optimizing LTO Backup Performance
Optimizing LTO Backup Performance July 19, 2011 Written by: Ash McCarty Contributors: Cedrick Burton Bob Dawson Vang Nguyen Richard Snook Table of Contents 1.0 Introduction... 3 2.0 Host System Configuration...
Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server
Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket node for PRIMERGY CX420 cluster Strong Performance and Cluster
ServeRAID Adapter Quick Reference
ServeRAID Adapter Quick Reference Technote Abstract Have you ever picked up an adapter that you know is a ServeRAID adapter, but do not know which model? This tip is a quick reference guide to the different
The Bus (PCI and PCI-Express)
4 Jan, 2008 The Bus (PCI and PCI-Express) The CPU, memory, disks, and all the other devices in a computer have to be able to communicate and exchange data. The technology that connects them is called the
Vess. Architectural & Engineering Specifications For Video Surveillance. A2200 Series. www.promise.com. Version: 1.2 Feb, 2013
Vess A2200 Series Architectural & Engineering Specifications Version: 1.2 Feb, 2013 www.promise.com Copyright 2013 Promise Technology, Inc. All Rights Reserved. No part of this document may be reproduced
Technical White Paper ETERNUS DX8700 S2 Hardware Architecture
Technical White Paper ETERNUS DX8700 S2 Hardware Architecture Table of contents Management Summary and General Remarks 2 System Architecture 3 Controller Enclosure 5 Controller Module () 5 Cache and Backup
How To Build A Cisco Ukcsob420 M3 Blade Server
Data Sheet Cisco UCS B420 M3 Blade Server Product Overview The Cisco Unified Computing System (Cisco UCS ) combines Cisco UCS B-Series Blade Servers and C-Series Rack Servers with networking and storage
Using EonStor FC-host Storage Systems in VMware Infrastructure 3 and vsphere 4
Using EonStor FC-host Storage Systems in VMware Infrastructure 3 and vsphere 4 Application Note Abstract This application note explains the configure details of using Infortrend FC-host storage systems