2 IN VITRO ENAMEL THICKNESS MEASUREMENTS WITH ULTRASOUND Dr Khalid Hussain Sindi 1, Dr Nigel Lawrence Bubb 1, Miss Diana Lynn Gutteridge 1, Dr Joseph Anthony Evans 2 1 School of Dentistry, Faculty of Medicine and Health, University of Leeds, LS2 9LU, UK 2 School of Medicine, Faculty of Medicine and Health, University of Leeds, LS2 9LU, UK Corresponding author: Dr Khalid Hussain Sindi School of Dentistry Faculty of Medicine and Health, University of Leeds LS2 9LU Mobile: Fax: [email protected]
3 2 Abstract This work investigates the agreement between ultrasound and histological measurements of enamel thickness in vitro. Fifteen extracted human premolars were sectioned coronally to produce 30 sections. The enamel thickness of each specimen was measured with a 15 MHz hand-held ultrasound probe and verified with histology. The speed of sound (SOS) in enamel was established. Bland-Altman analysis, intra-class correlation (ICC) coefficient and Wilcoxon sign rank test was used to assess agreement. The mean SOS in enamel was 6191 ±199 ms -1. Bland-Altman limits of agreement were to 0.18 mm when the SOS for each specimen was used, and to 0.21 mm when the mean SOS was used. ICC agreement was 0.97 and the Wilcoxon sign rank test gave a p-value of Using the SOS of each specimen results in more accurate enamel thickness measurement. Ultrasound measurements showed good agreement with histology which highlights its potential for monitoring the progressive loss of enamel thickness in erosive tooth surface loss (TSL). Keywords: ultrasound; erosion; tooth wear; tooth surface loss; non-destructive; enamel thickness measurement
4 1 Introduction Ultrasound is a non-invasive, non-destructive imaging tool that has been used in medicine since the 1940s. Its first use as an imaging tool in dentistry was by Baum and coworkers (1963) who used an ultrasound device, originally designed for ophthalmology, to scan teeth in B-mode. However, the images produced were not of sufficient clarity to render the ultrasound device usable in the dental surgery. Later, research by Lees and Barber (1968) attempted to use ultrasound for examining teeth, with more encouraging results. Recently, Huysmans and Thijssen (2000) demonstrated that ultrasound can be used to measure enamel thickness in a sample of 9 extracted human incisors. Tagtekin et al. (2005) investigated ultrasound for monitoring occlusal enamel on worn molars in vitro and concluded that ultrasound was a promising tool for that task. Indeed, several studies have compared ultrasound measurements with histology, the gold standard in the field, but with mixed results (Harput et al. 2011; Louwerse et al. 2004; Slak et al. 2011; Tagtekin et al. 2005). One factor that may explain the variation between these studies is the assumed SOS in enamel. This value is used to derive the enamel thickness. The variation in the SOS within the enamel tissue of teeth is well established with a range between 4500 ms -1 and 6500 ms -1. Table 1 summarises the various reports. The variations in SOS occur both within single teeth and between different subjects and it is likely that much of the variation is due to the orientation of the enamel rods with respect to the incident ultrasound beam (John 2005). Sound travels faster in enamel rods that are parallel to the ultrasound beam and the opposite holds true. However, the reliability of the measurement itself is also influenced by the orientation of the ultrasound transducer with respect to the enamel surface. Ideally the measurements would be carried out at normal incidence. Dwyer-Joyce and co-workers (2010) investigated the incidence angle after which no echo was seen from the ADJ and found that in human molar
5 2 teeth, this angle was 10º. In a preliminary study investigating the echo amplitude from the external surface of synthetic incisors, we found that 50% of the echo amplitude plummeted when the incidence angle was 25º (Sindi 2013). This angle discrepancy between the two studies might be due to the non-planar nature of molar teeth compared to incisors. Of course, if the transducer is normal to the enamel surface when taking a measurement this will also ensure a consistent orientation of the beam relative to the enamel rods. For absolute measurement of enamel thickness, knowledge of the SOS is essential and hence it might be assumed that the SOS uncertainties preclude the use of ultrasound in routine clinical applications of enamel thickness assessment. On the other hand, if the enamel SOS does not change in a particular tooth over the time, then changes in enamel thickness can be monitored without knowledge of the SOS. This is the case in erosive tooth surface loss (TSL), a multifactorial disease that has increasing prevalence (Lussi and Jaeggi 2008). It is defined as the loss of hard dental tissues due to acids of non-bacterial origins (intrinsic, extrinsic or both) which causes enamel demineralisation. Erosive TSL causes poor aesthetics, deterioration of dental function, hypersensitivity and diagnosis is made by obtaining medical and dental history with thorough investigation of dietary intake. Early detection and monitoring of erosion is crucial to prevent its progression and avoid the aforementioned complications. To date, there is no in vivo dental tool available that can aid dentists in diagnosing and monitoring the progression (or stabilisation) of the erosive process reproducibly and quantitatively (Amaechi and Higham 2005). The currently used methods for monitoring erosive TSL are sequential study casts (Wickens 1999), silicone putty index (Shaw and Smith 1999), photographs and erosive TSL indices (Bartlett et al. 2008; Eccles 1979; Linkosalo and Markkanen 1985; Larsen et al. 2000; O Brien 1994; O Sullivan and Curzon 2000), which are
6 3 subjective, not reproducible and do not measure enamel in a sub-millimetre level. Laboratory-based methods, such as profilometry (Bartlett 2003), are costly and cannot be used in the dental surgery. Profilometry also requires an impression of the teeth from which replicas are made but it has been shown that impressions can lead to inaccurate measurements (Rodriguez and Bartlett 2011). One important question which arises is the extent to which it is possible to take a single assumed value of the SOS and use it to get a useful measure of enamel thickness. Hence the aim of this work was to assess the agreement between enamel thickness measurements by ultrasound and histology using the same SOS value for each tooth (selected as being the mean of our sample) and compare it with the agreement obtained when using individualised SOS values. This is important clinically since it would open the possibility of a routine clinical tool using a standard value. Materials and Methods Tooth Selection and Storage Fifteen extracted human premolar teeth were randomly chosen from the Skeletal Tissue Bank, University of Leeds, after obtaining ethical approval (130109/DS/19) from the Dental Research and Ethics Committee, University of Leeds, according to the Human Tissues Act 2004 (UK). The teeth were kept hydrated in 0.1% thymol (Sigma Aldrich, MO, USA) solution and stored in the laboratory refrigerator at 5 ºC. Sectioning of the Premolar Teeth and Storage Media The crowns of all premolars were inspected for near planar areas (buccally, palatally, mesially and distally) so that the cut sections could include these acoustically preferential regions. All 15 premolars were sectioned coronally using a cutting machine employing a
7 4 250 µm water cooled diamond cut-off wheel (Accutom, Struers, Denmark). Two disc shaped specimens with a thickness of 2.50 ±0.02 mm were obtained from each premolar s crown (an occlusal and cervical specimen) (Fig. 1A), which resulted in a total of 30 specimens. The specimen thickness was determined with a digital micrometer ( , Mitutoyo, Japan). The specimens were stored in labelled vials filled with Hanks Balanced Salt Solution (HBSS) (Thermoscientific, Hyclone Laboratories Inc., USA) in a refrigerator at 5 ºC for subsequent ultrasound measurements. Marking Specimens Each specimen was marked with a permanent marker (Twin tip, Sharpie, Newell Rubbermaid, Inc., USA) at two locations on the enamel surface (V and T in Fig. 1B). For each specimen, the V marked area was used to determine the SOS in that specimen. The T marked area was used to measure enamel thickness with ultrasound, which was then validated with histological measurements. Marks were made on the most planar areas of the specimens. The specimens were kept hydrated in HBSS at all times, except when measurements were performed. Ultrasound Setup Dental boxing wax (00609, Kerr, CA, USA) was used to secure the specimens on a microscopic glass slide in order to prevent moving or rocking while ultrasound readings (in the z plane in Figure 1B) were made from the pre-marked areas. A direct contact pulse-echo technique using a 15 MHz focussed transducer (VR-260, Olympus Inc., Waltham, USA) with a replaceable Perspex delay line that had a 2 mm tip was coupled to the enamel surface with a water drop (Huysmans and Thijssen 2000). The transducer was excited with a pulserreceiver unit (PR-5742, Olympus, MA, USA), and the waveforms were displayed on a
8 5 digital oscilloscope (LT-342, Lecroy, USA). When recognisable enamel layer echoes were displayed on the oscilloscope, 1000 sample traces were averaged and saved in ASCII format on a computer coupled to the oscilloscope. The calibration of the ultrasonic setup was checked using a Perspex block (assumed SOS 2700 ms -1 ) prior to tooth measurements. SOS Measurements in Enamel at V Marked areas The SOS was calculated using the range equation (Slak et al. 2011). In order to satisfy this equation and derive the SOS (v), the TOF (t) and the enamel thickness (d) at the V marked area in Figure 1B should be known. where d: enamel thickness v: SOS in enamel t: TOF Time of Flight Calculation at V Marked Areas Equation 1 The TOF measurements were made while the specimen was held with one hand and the transducer in the other (Tagtekin et al. 2005). The transducer tip was placed perpendicular to the V marked area on the enamel surface, while ensuring intimate contact between the tip and the surface (Fig. 2).
9 6 Three repeat measurements were obtained from each V marked area of each section. In the repeat measurements, the transducer was removed from the enamel surface and reapplied. The signal from each repeat measurement was averaged 1000 times by the oscilloscope before saving (Fig. 3). Figure 3 depicts a representative waveform with the first echo from the enamel surface and the second echo from the ADJ. Generally the ADJ echo was a smaller version of the enamel surface echo but there is clearly some uncertainty in the choice of the reference points in the waveform. A total of 90 TOF measurements were obtained from all sections. The TOF was calculated from the first peak corresponding to the Perspex-enamel interface and the second peak representing the amelo-dentinal junction (ADJ). When there were multiple consecutive peaks, the first peak was chosen. Once all TOF s were carried out for the 30 sections, thickness measurements of the V marked site was completed as discussed in the following section. Thickness Measurement at V and T Marked Areas Each tooth section was placed under a stereo microscope (Nippon, Kogako, Tokyo), equipped with a 20 W fibre-optic light source (Leica L2, Leica Microsystems GmbH, Wetzlar, Germany) and viewed at 20x magnification. A computer controlled digital microscope camera (Moticam 2300, Motic, Inc. Ltd., China) with a resolution of 3 Megapixels was mounted on one of the ocular eye pieces via an eye piece adapter, so that images could be taken without moving the setup. Before images were captured, a calibration slide provided by the manufacturer was used in order to calibrate the camera s software (Motek Images Plus, version 2.0 ML). Once the V marked area of the specimen was in the field of view and the enamel layer was in sharp focus, a digital image was taken and saved. The software that captured the images had a built-in line-measurement tool which was used to measure enamel thickness (d).
10 7 Three radial measurements were made at the V marked area and the mean was taken. The line measurement tool cursor was placed on the external enamel surface and was extended to the ADJ. The ADJ was sometimes ambiguous and therefore the contrast was adjusted until the boundary became clearer for a measurement to be taken. Care was exercised not to spend unnecessary dry time for the specimen. SOS in Enamel at V Marked Areas The SOS in enamel at the V marked area on all 30 specimens was obtained by incorporating the TOF and thickness values from this area in Equation 1. Enamel Thickness Measurements with Ultrasound at T Marked Areas To avoid bias in enamel thickness measurements, a different area (T in Fig. 1B) was chosen within the same section to measure enamel thickness, but this was not in the V marked area from which SOS measurements were made (because thickness was already known in that area). The enamel thickness at the T marked area in Figure 1B was calculated from the measured time of flight using the range formula. The enamel thickness at the T marked area was first measured using the mean SOS for all specimens and then using the SOS for each specimen, to know if there was any difference between the two SOSs when performing thickness measurements with ultrasound. The ultrasonic enamel thickness values at the T marked areas were verified by measuring enamel thickness at these areas using a stereo microscope following the method described previously. Statistical Methods The aim of the analysis was to examine the agreement in enamel thickness between histology and ultrasound, and also to examine SOS in enamel. This was done using three
11 8 different statistical approaches. The first method examined agreement using the Bland- Altman limits of agreement method (Bland and Altman 1986). In order to achieve an overall evaluation of the agreement, the intra-class correlation coefficient (ICC) test was used as a second method (Gilligan et al. 2011).This method involves dividing the total variability in enamel thicknesses into two components, the variation between different teeth, and the variation within measurements of the same teeth (i.e. measurements of the same teeth by different methods). The ICC is the proportion of the total variability between teeth. If the method is reproducible, then the majority of variation should be between teeth, with little variation between repeat measurements of the same teeth (within teeth). This would give an ICC value close to 1. The difference in SOS values between tooth sections was also examined. As the specimens came in pairs from the same teeth, the paired t-test was used for analysis. The third statistical method used was a hypothesis test. The null hypothesis was: there is no difference between measurements made with ultrasound and histology. The alternative hypothesis was: there is a difference between measurements made with ultrasound and histology. Prior to hypothesis testing, the Shapiro-Wilk test was used to check if the data was normally distributed. The significance level for the normality test was set at = If the p-value for the test was < 0.05 then the data were not normally distributed and a non-parametric test, such as the Wilcoxon sign rank test was used instead of the paired t-test. However, if the p-value was > 0.05 then the data were deemed normally distributed and the paired t-test was used. The significance level for the hypothesis test was set at = 0.05.
12 9 Results Premolar teeth were sectioned successfully yielding 30 sections and stored in HBSS. Permanent marks (at V and T areas) were successfully placed in each of the 30 sections (Fig. 4). A total of 180 ASCII data files were successfully obtained from the ultrasound measurements. Validation of the ultrasound measurements was checked by comparing the measurements with the true enamel thickness obtained from histology. SOS Measurement in Enamel at V Marked Areas The SOS values obtained from the 30 specimens have SOS values ranging from 5187 to 7222 ms -1 (SD±199 ms -1 ) The mean SOS in enamel was determined in this work at 6191 ± 199 ms -1. The mean values obtained for the occlusal and cervical sections were 6267 ms -1 and 6131 ms -1 respectively (SD ±210, 188 ms -1 ). The paired t-test was used to compare the differences in SOS between sections. These showed no significant difference using a paired t-test (p = 0.12) Verifying Ultrasonic Enamel Thickness Measurements The mean ultrasonic enamel thickness for 30 specimens (at T marked areas) using SOS of each specimen was 1.05 ± 0.03 mm (range mm) and the mean ultrasonic thickness using mean SOS of all specimens was 1.05 ± 0.04 mm (range mm). The mean histologic enamel thickness was 1.04 ± 0.03 mm (range mm). Agreement between Ultrasound and Histology Analyses were performed to examine the agreement in enamel thickness between ultrasound and histology. The initial analysis considered the agreement in terms of the actual difference (in mm). The Bland-Altman method was used for the analysis, and the results
13 10 showed that the mean difference between ultrasound and histology (using SOS of each specimen) was 0.01 ±0.09 mm with 95% Bland-Altman Limits of Agreement from to 0.18 mm (Fig. 5) The mean difference between ultrasound and histology (using SOS of all specimens) was 0.02 ±0.10 mm with 95% Bland-Altman Limits of Agreement from to 0.21 mm. The ICC agreement analysis was 0.97 which means there is almost excellent agreement between the methods. The Shapiro-Wilk test result was < 0.05 (p-value = 0.00) which indicated that the data was not normally distributed. The Wilcoxon sign rank test of ultrasound and histology gave a p-value of 0.55, which indicated that there were no statistically significant difference between ultrasound and histology. Discussion Ultrasound has been proposed as a potential tool for direct, non-destructive enamel thickness measurements. The majority of ultrasonic enamel thickness measurements reported in the literature assumed a constant SOS within the tooth and across other teeth. This attracts an element of uncertainty in the enamel thickness measurements because the SOS varies within and across teeth. A solution for this problem is to use information in the relative TOFs in the serial measurements. When the ultrasound transducer is placed on the enamel surface to take a measurement, what is being measured is the TOF, not the thickness (which requires an SOS to be calculated using the range equation). The TOF will be the point of interest here, because if it decreases, it means that some enamel has been lost, provided the transducer is perpendicular to the enamel surface. SOS Measurement in Enamel at V Marked Areas In this work, the mean SOS value for the 30 sections, 6191 (SD ±199 ms -1 ), was in very good agreement with the reported literature values (see Fig. 6). There is a wide range in
14 11 SOS across the specimens ( ms -1 ), which was not surprising as the SOS has been reported to be different across different teeth and within the same tooth. John (2005) has demonstrated that SOS in a tooth can vary depending on how parallel the ultrasound wave is to the enamel rods. Enamel rods vary in orientation along the enamel layer where some rods lie perpendicular to the ADJ others lie parallel to it (Lees and Rollins 1972) which explains the higher SOS values shown in Figure 6. This also means that V marked areas might not necessarily have the same SOS present in T marked areas. Furthermore, anisotropy in teeth has been reported by several studies as a primary obstacle for the utilisation of diagnostic ultrasound in dentistry (Harput et al. 2011; Huysmans and Thijssen 2000; Louwerse et al. 2004; Slak et al. 2011; Tagtekin et al. 2005). However our results showed no statistically significant difference (p-value = 0.12) in SOS values between the two sections (occlusal and cervical), which suggests that the site of measurement on the individual tooth is not critical although this might be due to the relatively close proximity of both sections. Enamel Thickness Measurements with Ultrasound at T Marked Areas The results from this work showed very good agreement between ultrasound and histology in measuring enamel thickness in premolars, which means that the ultrasonic system was accurate and effective in measuring enamel thickness. The results indicated that in all analyses there was a relatively small mean difference between the two methods. This means there is no consistent trend of ultrasound over- or under-predicting enamel thickness. The mean percentage difference between ultrasound and histology was 1.05 ±6.34%. This is better than the in vitro findings of Slak and co-workers (2011) which reported a ~12.00% difference in enamel thickness between ultrasound and histology from a sample of 4 human central incisors.
15 12 It is well established that the accuracy of ultrasound in measuring the true enamel thickness depends on the SOS in enamel, which varies across different individuals and different teeth. Since Slak and co-workers (2011) have determined the SOS in enamel in one of the teeth and used its mean SOS value in subsequent measurements for other teeth, it is not surprising to see a difference between the measured value and the true value. This explains the higher accuracy achieved in this work because the SOS was determined for each specimen and a mean SOS value was not used for all specimens. Also, the paired t-test results demonstrated that there was no statistically significant difference between ultrasound and histology (p-value = 0.46). It also confirms that the second ultrasound echo actually arises from the same location as the histological ADJ. Assuming an SOS of 6191m s -1 the wavelength at 15MHz is 0.41mm. The enamel thicknesses measured ranged from 0.50 to 1.50 mm. Hence it is at least feasible in principle that the two reflecting surfaces can be separately distinguished. Some authors (Longo et al. 2010) have outlined methods by which the SOS can be determined simultaneously and this may be developed further in the future. Using the mean difference as a measure of accuracy between two methods is acceptable for assessing the overall accuracy of the measurements which shows how ultrasound under/overestimates the histology measurements. However, if the aim was to assess for each tooth how ultrasound agrees with the histology measurements, then it is best to calculate the 95% limits of agreement (Bland and Altman 1986) and report this value as the accuracy of the ultrasonic technique. Using this approach, the results showed that the majority of the ultrasound measurements are within approximately 10% of the histology measurements. The 10% difference in the measurements may have arisen due to the non-planar nature of premolars which means that the transducer tip was not perpendicular to the enamel surface while taking measurement. This results in smaller echoes that are difficult to recognise in the waveform (Slak et al. 2011). It seems clear that the enamel thickness
16 13 cannot be measured everywhere (i.e. non-planar areas), but on the other hand, erosive tooth surface loss is known to affect the buccal surface of anterior teeth (incisors) more readily because of the direct contact with the acidic foodstuff and drinks one consumes. A study by Sindi and co-workers (2014) showed that central incisors generally are amenable to monitoring enamel thickness clinically with a reproducibility of better than 0.10 mm. It is likely that measurements on molars and premolars will be poorer and may not become usable clinically because of their curvaceous nature. The ICC obtained in this work (0.96) means that the majority of the differences were between teeth and not within measurements of the same teeth (measurements of the same teeth by ultrasound and histology). Therefore there is a high level of agreement between ultrasound and histology measurements. An in vitro study has measured enamel thickness on worn cusps of molar teeth with ultrasound before and after abrading the cusps with abrasive paper (Tagtekin et al. 2005) They verified the results with histological sections and found a moderate correlation between both methods (ultrasound and histology) but not perfect agreement. This could be due to the use of one SOS value (6132 ± 2.5 ms -1 ) for all teeth which may have caused inaccuracies in their results. To investigate this further, the mean SOS for all the specimens in this work was used to calculate the enamel thickness using the same TOF data used earlier. The 95% limits of agreement increased to to 0.21 mm compared to to 0.18 mm. This demonstrates that using the specific SOS rather than mean values results in a more accurate measurement. This is an important distinction between previous work by other researchers and our work, where the enamel thickness obtained for each section was based on its own SOS measurement.
17 14 For the purpose of measuring progressive loss of enamel thickness the important thing is the ability to reproducibly measure the change in thickness from baseline rather than the remaining enamel thickness value. If the current system was to be used on maxillary central incisors it would be expected to produce more accurate results, because planar and larger central incisors would reflect stronger echoes that are easier to identify. It is important to note that there is scope for improving the agreement between ultrasound and histological measurements. This could be achieved by signal processing, to increase the signal-to-noise ratio which renders reflected echoes easier to locate. Harput and co-workers (2011) used the fractional Fourier transform (FrFt) to improve the definition of the enamel surface and ADJ echoes. They investigated signal loss in human teeth and used a custom-made wave excitation technique known as linear frequency modulated (LFM) chirp excitation that is tailored for individual teeth. This allows most of the ultrasound wave to be targeted into the tooth and separated from overlapping echoes which makes their detection easier. However, implementing this technique requires a solid background in signal analysis and programming, which is beyond the scope of this article. Nevertheless, it would be an interesting method to learn and adopt in future experiments involving ultrasound and dental applications. Conclusions Ultrasound shows promise as a non-destructive technique for measuring enamel and monitoring erosive TSL. The ultrasound technique used here was accurate and within 10% of histological measurements, which renders the technique promising for serial monitoring of enamel thickness.
18 15 Tables Table 1. Speed of sound (SOS) in enamel as reported in several published studies (ms -1 ). Study SOS (ms -1 ) Tooth type Huysmans and Thijssen (2000) 6500 Human incisors Ng et al. (1989) 6450 Human incisors and molars Barber (1969), Blodgett (2002) 6250 Human incisors Hamano et al. (2003) 6244 Human molars Ghorayeb and Valle (2002) 6200 Human molars Bozkurt et al. (2005) 6132 Human premolars Slak et al. (2011) 6100 Human incisors Lees and Barber (1971) 6000 Human molars Maev et al. (2002) 5900 Human molars Hedrick et al. (1995) 5800 Incisors and molars Reich et al. (1967) Kossof and Sharpe (1966) 4500 Human incisors and molars
19 16 Acknowledgments The authors would like to thank the Saudi Arabian Ministry of Health for their full sponsorship and support; the Saudi Arabian Cultural Bureau for overseeing this sponsorship; Mrs Jackie Hudson for help with the histological sections; Dr Jing Kang for the statistical support and Mr Mohammed Khan for the macro.
20 17 References Amaechi BT, Higham SM. Dental erosion: Possible approaches to prevention and control. J Dent 2005;33: Barber FE, Lees S and Lobene RR. Ultrasonic pulse-echo measurements in teeth. Arch Oral Biol 1969;14: Bartlett D. Retrospective long term monitoring of tooth wear using study models. Br Dent J. 2003;194: Bartlett D, Ganss C, Lussi A. Basic erosive wear examination (BEWE): A new scoring system for scientific and clinical needs. Clin Oral Investig 2008;12:S Baum G, Greenwood I, Slawski S, Smirnow R. Observation of internal structures of teeth by ultrasonography. Science 1963;139: Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1: Blodgett DW. Ultrasonic assessment of tooth structure. In: Proceedings of the Society of Photo-optical Instrumentation Engineers conference, Laser Tissue Interaction XIII: Photochemical, Photothermal, and Photomechanical, 27 June 2002, San Jose, California, USA: Bozkurt F, Tagtekin D, Hayran O, Stookey G and Yanikoglu F. Accuracy of ultrasound measurement of progressive change in occlusal enamel thickness. Oral Surg Oral Med Oral Pathol Oral Radiol 2005;99:
21 18 Dwyer-Joyce RS, Goodman MA and Lewis R. A comparative study of ultrasonic direct contact, immersion, and layer resonance methods for assessment of enamel thickness in teeth. P I Mech Eng J-J Eng 2010;224: Eccles JD. Dental erosion of nonindustrial origin. A clinical survey and classification. J Prosthet Dent 1979;42: Ghorayeb SR and Valle T. Experimental evaluation of human teeth using noninvasive ultrasound: Echodentography. IEEE Trans Ultrason Ferroelectr Freq Control 2002;49: Gilligan T, Nelson L, McLeod L, Dalal AA. Prm42 visually evaluating the measurement comparability between paper-based and alternate versions of administration of the lung function questionnaire. Value Health 2011;14:A153. Hamano N, Hanaoka K, Ebihara K, Toyoda M and Teranaka T. Evaluation of adhesive defects using an ultrasonic pulse-reflection technique. Dent Mater 2003;22: Harput S, Evans T, Bubb N, Freear S. Diagnostic ultrasound tooth imaging using fractional Fourier transform. IEEE Trans Ultrason Ferroelectr Freq Control 2011;58: Hedrick WR, Hykes DL, Starchman DE and Wilson TA. Ultrasound physics and instrumentation 1995; St. Louis, MI, USA: Mosby. Huysmans M, Thijssen J. Ultrasonic measurement of enamel thickness: A tool for monitoring dental erosion?. J Dent 2000;28: John C. Directing ultrasound at the cemento-enamel junction (CEJ) of human teeth: I. Asymmetry of ultrasonic path lengths. Ultrasonics 2005;43:
22 19 Kossoff G and Sharpe CJ. Examination of the contents of the pulp cavity in teeth. Ultrasonics 1966;4: Larsen IB, Westergaard J, Stoltze K, Larsen AI, Gyntelberg F, Holmstrup P. A clinical index for evaluating and monitoring dental erosion. Community Dent Oral Epidemiol 2000;28: Lees S and Barber FE. Looking into teeth with ultrasound. Science 1968; 161: Lees S and Barber FE. Looking into the tooth and its surfaces with ultrasonics. Ultrasonics 1971;9: Lees S, Rollins Jr FR. Anisotropy in hard dental tissues. J Biomech 1972;5: Linkosalo E, Markkanen H. Dental erosions in relation to lactovegetarian diet. Scand J Dent Res 1985;93: Longo R, Grimal Q, Laugier P, Vanlanduit S, Guillaume P. IEEE Trans Ultrason Ferroelectr Freq Control 2010;57: Louwerse C, Kjaeldgaard M, Huysmans MC. The reproducibility of ultrasonic enamel thickness measurements: An in vitro study. J Dent 2004;32: Lussi A, Jaeggi T. Erosion--diagnosis and risk factors. Clin Oral Investig 2008;12:S5-13. Maev RG, Denisova LA, Maeva EY, Denissov AA. New data on histology and physicomechanical properties of human tooth tissue obtained with acoustic microscopy. Ultrasound Med Biol 2002;28: Ng SY, Payne PA, Cartledge NA and Ferguson MJ. Determination of ultrasonic velocity in human enamel and dentine. Arch Oral Biol 1989;34:
23 20 O'Brien M. Children's dental health in the United Kingdom London: Her Majesty s Stationery Office O'Sullivan EA, Curzon ME. A comparison of acidic dietary factors in children with and without dental erosion. ASDC J Dent Child 2000;67: , 160. Reich F, Brenden B and Porter N. Ultrasonic imaging of teeth. Report of battelle memorial institute 1967; Pacific Northwest Laboratory, Richland, Washington. Rodriguez JM, Bartlett DW. The dimensional stability of impression materials and its effect on in vitro tooth wear studies. Dent Mater 2011;27: Shaw L and Smith A. Dental erosion the problem and some practical solutions. Br Dent J 1999;186: Sindi KH. In vitro and in vivo feasibility study of ultrasound for monitoring tooth surface loss. PhD thesis 2013; University of Leeds. Sindi KH, Bubb NL, Evans JA, Gutteridge DL. In vivo reproducibility study of ultrasound for monitoring enamel thickness. Oral Surg Oral Med Oral Pathol Oral Radiol 2014;118: Slak B, Ambroziak A, Strumban E, Maev RG. Enamel thickness measurement with a high frequency ultrasonic transducer-based hand-held probe for potential application in the dental veneer placing procedure. Acta Bioeng Biomech 2011;13: Tagtekin D, Oztürk F, Lagerweij M, Hayran O, Stookey G, Caliskan Yanikoglu F. Thickness measurement of worn molar cusps by ultrasound. Caries Res 2005;39: Wickens J. Tooth surface loss. 6. Prevention and maintenance. Br Dent J 1999;186:
24 21 Figure Captions Fig. 1. Schematic for the location and orientation of the sections. Fig. 2. The transducer Perspex tip coupled with water to enamel on the pre-marked area. Note the marker colour on the proximal area. Fig. 3. Representative ultrasonic waveform depicting the enamel surface echo and the amelodentinal junction echo (ADJ) Fig. 4. Coronal section of a representative specimen at a marked area on enamel. Note that extending the mark to the cut surface was necessary for the histological measurements. Fig. 5. Bland-Altman plot for enamel thickness measurements with histology and ultrasound using the SOS from each specimen (n = 30). Fig. 6. A histogram showing SOS result across a sample of 30 sections from 15 premolar teeth. SOS values from the literature are also shown.
Pattern Classification Techniques for the Ultrasonographic Periodontal Probe Introduction Figure 1:
Pattern Classification Techniques for the Ultrasonographic Periodontal Probe Crystal Bertoncini Nondestructive Evaluation Laboratory The College of William and Mary Introduction In the clinical practice
In vitro examination of human teeth using ultrasound and X-ray diffraction
Acta of Bioengineering and Biomechanics Vol. 6, No. 1, 2004 In vitro examination of human teeth using ultrasound and X-ray diffraction HELENA GAWDA, LESZEK SĘKOWSKI, HANNA TRĘBACZ Department of Biophysics,
Non-carious dental conditions
Non-carious dental conditions Children s Dental Health in the United Kingdom, 2003 Barbara Chadwick, Liz Pendry October 2004 Crown copyright 2004 Office for National Statistics 1 Drummond Gate London SW1V
CLASSIFICATION OF CARIOUS LESIONS AND TOOTH PREPARATION.
CLASSIFICATION OF CARIOUS LESIONS AND TOOTH PREPARATION. ١ G.V. BLACK who is known as the father of operative dentistry,he classified carious lesions into groups according to their locations in permanent
Dental caries is an infectious disease caused
Emerging Methods of Caries Diagnosis George K. Stookey, Ph.D.; Carlos González-Cabezas, D.D.S., Ph.D. Abstract: Current diagnostic tools used in dental caries detection are not sensitive enough to diagnose
DESIGN AND EVALUATION OF PROBE WITH THREE DEGREE- OF-FREEDOM FOR NON-DESTRUCTIVE TEST USING THREE- DIMENSIONAL FINITE ELEMENT METHOD
DESIGN AND EVALUATION OF PROBE WITH THREE DEGREE- OF-FREEDOM FOR NON-DESTRUCTIVE TEST USING THREE- DIMENSIONAL FINITE ELEMENT METHOD Masafumi Aoyanagi Graduate School of Systems and Information Engineering,
Eliminating effect of Er, Cr: YSGG laser irradiation on the smear layer of dentin
Eliminating effect of Er, Cr: YSGG laser irradiation on the smear layer of dentin Jingtao Yu, MD, DDS, and Lu Yan, MD, DDS College of Stomatology, China Medical University, Shenyang, P. R. China Purpose:
CHAPTER 10 RESTS AND PREPARATIONS. 4. Serve as a reference point for evaluating the fit of the framework to the teeth.
CHAPTER 10 RESTS AND DEFINITIONS A REST is any rigid part of an RPD framework which contacts a properly prepared surface of a tooth. A REST PREPARATION or REST SEAT is any portion of a tooth or restoration
Robot Perception Continued
Robot Perception Continued 1 Visual Perception Visual Odometry Reconstruction Recognition CS 685 11 Range Sensing strategies Active range sensors Ultrasound Laser range sensor Slides adopted from Siegwart
Ultrasonic Wave Propagation Review
Ultrasonic Wave Propagation Review Presented by: Sami El-Ali 1 1. Introduction Ultrasonic refers to any study or application of sound waves that are higher frequency than the human audible range. Ultrasonic
Scanning Acoustic Microscopy Training
Scanning Acoustic Microscopy Training This presentation and images are copyrighted by Sonix, Inc. They may not be copied, reproduced, modified, published, uploaded, posted, transmitted, or distributed
Full Crown Module: Learner Level 1
Full Crown Module Restoration / Tooth # Full Gold Crown (FGC) / 30 Extensions: Porcelain Fused to Metal (PFM) / 12 All Ceramic / 8 Learner Level 1 Mastery of Tooth Preparation Estimated Set Up Time: 30
Accuracy of space analysis with emodels and plaster models
ORIGINAL ARTICLE Accuracy of space analysis with emodels and plaster models S. Russell Mullen, a Chris A. Martin, b Peter Ngan, c and Marcia Gladwin d Leesburg, Va, and Morgantown, WVa Introduction: The
Children s Dental Health in the United Kingdom, 2003
Children s Dental Health in the United Kingdom, 2003 Summary Report Deborah Lader Barbara Chadwick Ivor Chestnutt Rachael Harker John Morris Nigel Nuttall Nigel Pitts Jimmy Steele Deborah White Crown copyright
Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications
Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications Janet E. Semmens Sonoscan, Inc. 2149 E. Pratt Boulevard Elk Grove Village, IL 60007 USA Phone: (847)
HEALTH SERVICES POLICY & PROCEDURE MANUAL. SUBJECT: Types of Dental Treatments Provided EFFECTIVE DATE: July 2014 SUPERCEDES DATE: January 2014
PAGE 1 of 5 References Related ACA Standards 4 th Edition Standards for Adult Correctional Institutions 4-4369, 4-4375 PURPOSE To provide guidelines for determining appropriate levels of care and types
Projecting a new smile from a facial photograph:
I special _ digital smile design Projecting a new smile from a facial photograph: A new way to plan multidisciplinarydental treatments Authors_ Drs Marco Del Corso, Italy, & Alain Méthot, Canada without
Tooth preparation J. C. Davenport, 1 R. M. Basker, 2 J. R. Heath, 3 J. P. Ralph, 4 P-O. Glantz, 5 and P. Hammond, 6
12 5 Tooth preparation J. C. Davenport, 1 R. M. Basker, 2 J. R. Heath, 3 J. P. Ralph, 4 P-O. Glantz, 5 and P. Hammond, 6 This final article in the series describes the modification of teeth to improve
A comparison of blood glucose meters in Australia
Diabetes Research and Clinical Practice 71 (2006) 113 118 www.elsevier.com/locate/diabres A comparison of blood glucose meters in Australia Matthew Cohen *, Erin Boyle, Carol Delaney, Jonathan Shaw International
WAVELET ANALYSIS BASED ULTRASONIC NONDESTRUCTIVE TESTING OF POLYMER BONDED EXPLOSIVE
WAVELET ANALYSIS BASED ULTRASONIC NONDESTRUCTIVE TESTING OF POLYMER BONDED EXPLOSIVE Weibin Zhang, Yong Tian, Zhanfeng Yang, Liling Wang Institute of Chemical Materials, China Academy of Engineering Physics,
E190Q Lecture 5 Autonomous Robot Navigation
E190Q Lecture 5 Autonomous Robot Navigation Instructor: Chris Clark Semester: Spring 2014 1 Figures courtesy of Siegwart & Nourbakhsh Control Structures Planning Based Control Prior Knowledge Operator
P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)
INSURANCE SCAM OPTICS - LABORATORY INVESTIGATION P R E A M B L E The original form of the problem is an Experimental Group Research Project, undertaken by students organised into small groups working as
To measure an object length, note the number of divisions spanned by the object then multiply by the conversion factor for the magnification used.
STAGE MICROMETERS Introduction Whenever there is a need to make measurements with an eyepiece graticule, there is also a need to ensure that the microscope is calibrated. The use of a stage micrometer
Effect of CPP ACP paste on mechanical properties of bovine enamel as determined by an ultrasonic device
Journal of Dentistry (2006) 34, 230 236 www.intl.elsevierhealth.com/journals/jden Effect of CPP ACP paste on mechanical properties of bovine enamel as determined by an ultrasonic device Kanako Yamaguchi
Measure of Confidence. Glaucoma Module Premium Edition
Measure of Confidence Glaucoma Module Premium Edition The Changing Face of Glaucoma Practice Literature 1 Leske et al., Arch Ophthalmol 1997; 115:1051-1057 2 Doughty et al., Surv Ophthalmol 2000; 44:367-408
PROPORTIONS. The new Golden Rules in dentistry. History. Abstract
M PROPORTIONS The new Golden Rules in dentistry Dr. Alain Méthot Abstract Since the beginning Cosmetic Dentistry has been using the principles of Golden Proportion (1: 0.618) as a guideline for smile design...
A. DEVELOPMENT OF THE DENTAL ORGAN (ENAMEL ORGAN):
A. DEVELOPMENT OF THE DENTAL ORGAN (ENAMEL ORGAN): AS EARLY AS THE SECOND MONTH OF FETAL LIFE, THE DEVELOPMENT OF THE DECIDUOUS TEETH MAY FIRST BECOME EVIDENT. 1. Dental lamina and Bud stage At about six
Nano Meter Stepping Drive of Surface Acoustic Wave Motor
Proc. of 1st IEEE Conf. on Nanotechnology, Oct. 28-3, pp. 495-5, (21) Maui, Hawaii Nano Meter Stepping Drive of Surface Acoustic Wave Motor Takashi Shigematsu*, Minoru Kuribayashi Kurosawa*, and Katsuhiko
The total occlusal convergence of the abutment of a partial fixed dental prosthesis: A definition and a clinical technique for its assessment
Review Article The total occlusal convergence of the abutment of a partial fixed dental prosthesis: A definition and a clinical technique for its assessment John S. Mamoun 1 Correspondence: Dr. John S.
Introduction to Dental Anatomy
Introduction to Dental Anatomy Vickie P. Overman, RDH, MEd Continuing Education Units: N/A This continuing education course is intended for dental students and dental hygiene students. Maintaining the
Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment
Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment by Dr. Ronald Jung and Master Dental Technician Xavier Zahno Initial situation
Oftentimes, as implant surgeons, we are
CLINICAL AVOIDING INJURY TO THE INFERIOR ALVEOLAR NERVE BY ROUTINE USE OF INTRAOPERATIVE RADIOGRAPHS DURING IMPLANT PLACEMENT Jeffrey Burstein, DDS, MD; Chris Mastin, DMD; Bach Le, DDS, MD Injury to the
BIOMEDICAL ULTRASOUND
BIOMEDICAL ULTRASOUND Goals: To become familiar with: Ultrasound wave Wave propagation and Scattering Mechanisms of Tissue Damage Biomedical Ultrasound Transducers Biomedical Ultrasound Imaging Ultrasonic
This paper summarizes current trends in the
Clinical Diagnosis of Dental Caries: A North American Perspective Stephen F. Rosenstiel, B.D.S., M.S.D. Abstract: This paper summarizes current trends in the clinical diagnosis of occlusal caries in response
Doppler ultrasound to detect pulpal blood flow changes during local anaesthesia
doi:1.1111/j.1365-2591.11.19.x Doppler ultrasound to detect pulpal blood flow changes during local anaesthesia M. J. Yoon, S. J. Lee, E. Kim & S. H. Park Department of Operative Dentistry, College of Dentistry,
Ando A., Nakamura Y., Kanbara R., Kumano H., Miyata T., Masuda T., Ohno Y. and Tanaka Y.
11. The Effect of Abutment Tooth Connection with Extracoronal Attachment using the Three Dimensional Finite Element Method - Part 2. The Construction of Finite Element Model from CT Data - Ando A., Nakamura
PUMPED Nd:YAG LASER. Last Revision: August 21, 2007
PUMPED Nd:YAG LASER Last Revision: August 21, 2007 QUESTION TO BE INVESTIGATED: How can an efficient atomic transition laser be constructed and characterized? INTRODUCTION: This lab exercise will allow
Integrated sensors for robotic laser welding
Proceedings of the Third International WLT-Conference on Lasers in Manufacturing 2005,Munich, June 2005 Integrated sensors for robotic laser welding D. Iakovou *, R.G.K.M Aarts, J. Meijer University of
Ultrasound crack detection in a simulated human tooth
(005) 34, 80 85 q 005 The British Institute of Radiology http://dmfr.birjournals.org RESEARCH Ultrasound crack detection in a simulated human tooth MO Culjat 1, RS Singh 1, ER Brown, RR Neurgaonkar 3,
Modern Tooth Replacement Strategies & Digital Workflow
Modern Tooth Replacement Strategies & Digital Workflow Case Studies by Dr Maurice Salama, DMD AS PUBLISHED BY Dentistry Today, June 2014 Complete Implant Restoration System FACTS: Implant Dentistry Has
Dr. Little received his doctorate degree in dentistry from UT Health at San Antonio Dental
Implant Solutions for the Implant Patient: Diagnosis and Treatment Planning for Predictable Results David Little, DDS 6961 U.S. Highway 87 East San Antonio, TX 78263 Phone: (210)648-4411 Fax: (210) 648-6498
Duplication Images in Vascular Sonography
Article Duplication Images in Vascular Sonography Jonathan M. Rubin, MD, PhD, Jing Gao, MD, Keith Hetel, MD, Robert Min, MD Objective. The purpose of this study was to determine the characteristics and
FXA 2008. UNIT G485 Module 4 5.4.3 Ultrasound. Candidates should be able to :
1 Candidates should be able to : ULTRASOUND Describe the properties of ultrasound. ULTRASOUND is any sound wave having a frequency greater than the upper frequency limit of human hearing (20 khz). Describe
porcelain fused to metal crown
Lectur.5 Dr.Adel F.Ibraheem porcelain fused to metal crown the most widely used fixed restoration,it is full metal crown having facial surface (or all surfaces) covered by ceramic material. It consist
MEDICAID DENTAL PROGRAMS CODING, POLICY AND RELATED FEE REVISION INFORMATION
MEDICAID DENTAL PROGRAMS CODING, POLICY AND RELATED FEE REVISION INFORMATION Effective for dates of service on and after November 1, 2005, the following dental coding, policy and related fee revisions
Acoustic GHz-Microscopy: Potential, Challenges and Applications
Acoustic GHz-Microscopy: Potential, Challenges and Applications A Joint Development of PVA TePLa Analytical Systems GmbH and Fraunhofer IWM-Halle Dr. Sebastian Brand (Ph.D.) Fraunhofer CAM Fraunhofer Institute
Long-term Survival of Direct and Indirect Restorations Placed for the Treatment of Advanced Tooth Wear
Eur. J. Prosthodont. Rest. Dent., Vol.15, No. 1, pp 2-6 Printed in Great Britain 2007 FDI World Dental Press Ltd. Long-term Survival of Direct and Indirect Restorations Placed for the Treatment of Advanced
Rock Bolt Condition Monitoring Using Ultrasonic Guided Waves
Rock Bolt Condition Monitoring Using Ultrasonic Guided Waves Bennie Buys Department of Mechanical and Aeronautical Engineering University of Pretoria Introduction Rock Bolts and their associated problems
Engineering Sciences 151. Electromagnetic Communication Laboratory Assignment 3 Fall Term 1998-99
Engineering Sciences 151 Electromagnetic Communication Laboratory Assignment 3 Fall Term 1998-99 WAVE PROPAGATION II: HIGH FREQUENCY SLOTTED LINE AND REFLECTOMETER MEASUREMENTS OBJECTIVES: To build greater
STATISTICAL ANALYSIS OF ULTRASOUND ECHO FOR SKIN LESIONS CLASSIFICATION HANNA PIOTRZKOWSKA, JERZY LITNIEWSKI, ELŻBIETA SZYMAŃSKA *, ANDRZEJ NOWICKI
STATISTICAL ANALYSIS OF ULTRASOUND ECHO FOR SKIN LESIONS CLASSIFICATION HANNA PIOTRZKOWSKA, JERZY LITNIEWSKI, ELŻBIETA SZYMAŃSKA *, ANDRZEJ NOWICKI Institute of Fundamental Technological Research, Department
BARE PCB INSPECTION BY MEAN OF ECT TECHNIQUE WITH SPIN-VALVE GMR SENSOR
BARE PCB INSPECTION BY MEAN OF ECT TECHNIQUE WITH SPIN-VALVE GMR SENSOR K. Chomsuwan 1, S. Yamada 1, M. Iwahara 1, H. Wakiwaka 2, T. Taniguchi 3, and S. Shoji 4 1 Kanazawa University, Kanazawa, Japan;
X X X a) perfect linear correlation b) no correlation c) positive correlation (r = 1) (r = 0) (0 < r < 1)
CORRELATION AND REGRESSION / 47 CHAPTER EIGHT CORRELATION AND REGRESSION Correlation and regression are statistical methods that are commonly used in the medical literature to compare two or more variables.
Full Crown Module: Learner Level 3
Full Crown Module Restoration / Tooth # Full Gold Crown (FGC) / mesially tilted 30 Extensions: Porcelain Fused to Metal (PFM) / lingually 21 All Ceramic / rotated 12 Learner Level 3 Preparation of Malpositioned
Structur. Structur 2 SC / Structur Premium EXCELLENT TEMPORARIES WITH STRUCTUR
Structur Structur 2 SC / Structur Premium EXCELLENT TEMPORARIES WITH STRUCTUR Simple to use Reliable products are required to provide your patients with prosthetic treatments, especially with regard to
In the Spring of 2010, the American Academy of Cosmetic
Greetings to the members of the American Academy of Cosmetic Dentistry (AACD). As you know, a sisterhood agreement was concluded between the AACD and the Japan Academy of Esthetic Dentistry (JAED) at a
Digital impression solutions. 3M True Definition Scanner. Precise. impressions. in a jiffy
Digital impression solutions 3M True Definition Scanner Precise impressions in a jiffy True Definition Scanner Digital impressioning redefined Easy handling. Desired result. With the 3M True Definition
The promise of ultrasonic phased arrays and the role of modeling in specifying systems
1 modeling in specifying systems ABSTRACT Guillaume Neau and Deborah Hopkins This article illustrates the advantages of phased-array systems and the value of modeling through several examples taken from
Non-destructive testing Ð Ultrasonic examination
BRITISH STANDARD BS EN 583-3 : 1997 The European Standard has the status of a British Standard ICS 19.100 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW Non-destructive testing
Guidelines for Referrals for Orthodontic Treatment
Advice for General Dental Practitioners, PCTs and LHBs Guidelines for Referrals for Orthodontic Treatment This document has been produced by the British Orthodontic Society Guidelines for Referrals for
High Resolution Spatial Electroluminescence Imaging of Photovoltaic Modules
High Resolution Spatial Electroluminescence Imaging of Photovoltaic Modules Abstract J.L. Crozier, E.E. van Dyk, F.J. Vorster Nelson Mandela Metropolitan University Electroluminescence (EL) is a useful
IMPLANT DENTISTRY EXAM BANK
IMPLANT DENTISTRY EXAM BANK 1. Define osseointegration. (4 points, 1/4 2. What are the critical components of an acceptable clinical trial? (10 points) 3. Compare the masticatory performance of individuals
Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications
Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications Saulius Marcinkevičius Optics, ICT, KTH 1 Outline Optical near field. Principle of scanning near field optical microscope
Evaluation of Initial Setting Time of Fresh Concrete
Evaluation of Initial Setting Time of Fresh Concrete R R C Piyasena, P A T S Premerathne, B T D Perera, S M A Nanayakkara Abstract According to ASTM 403C, initial setting time of concrete is measured based
Phased-Array ROWA-SPA: High-performance testing machine for combined, 100-percent automated testing of square and round bars
11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Phased-Array ROWA-SPA: High-performance testing machine for combined, 100-percent automated
HOW GOOD ARE ELECTRICAL DIAGNOSTIC TESTS TO PREDICT WATER TREES IN HV CABLES AN EVALUATION USING OPTICAL MICROSCOPY
Journal of ELECTRICAL ENGINEERING, VOL. 56, NO. 1-2, 25, 31 35 HOW GOOD ARE ELECTRICAL DIAGNOSTIC TESTS TO PREDICT WATER TREES IN HV CABLES AN EVALUATION USING OPTICAL MICROSCOPY Motaheruddin Ahmed Mohammad
Resorptive Changes of Maxillary and Mandibular Bone Structures in Removable Denture Wearers
Resorptive Changes of Maxillary and Mandibular Bone Structures in Removable Denture Wearers Dubravka KnezoviÊ-ZlatariÊ Asja»elebiÊ Biserka LaziÊ Department of Prosthodontics School of Dental Medicine University
FABRICATING CUSTOM ABUTMENTS
FABRICATING CUSTOM ABUTMENTS LUC AND PATRICK RUTTEN How much should a Dental Technician know about the clinical aspects of implantology? The answer is clear: as much as possible. This is the distinction
Bitewing Radiography B.E. DIXON. B.D.S., M.Sc., D.P.D.S.
Bitewing Radiography B.E. DIXON B.D.S., M.Sc., D.P.D.S. Main Indications Detection of Dental Caries Monitoring progression of caries Assessment of existing restorations Assessment of Periodontal status
Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19
Doppler Doppler Chapter 19 A moving train with a trumpet player holding the same tone for a very long time travels from your left to your right. The tone changes relative the motion of you (receiver) and
Hunting Bats. Diagnostic Ultrasound. Ultrasound Real-time modality
Diagnostik Ultrasound Basic physics, image reconstruction and signal processing Per Åke Olofsson Dpt of Biomedical Engineering, Malmö University Hospital, Sweden Ultrasound Real-time modality 17-WEEK FETAL
Seeing CAD/CAM in a new light.
CAD/ CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS CEREC NEW PRODUCTS 2009 Seeing CAD/CAM in a new light. T h e D e n t a l C o m p a n y Precision and simplicity redefined.
4-1-2005. Dental Clinical Criteria and Documentation Requirements
4-1-2005 Dental Clinical Criteria and Documentation Requirements Table of Contents Dental Clinical Criteria Cast Restorations and Veneer Procedures... Pages 1-3 Crown Repair... Page 3 Endodontic Procedures...
Anatomic Anomalies. Anomalies. Anomalies. Anomalies. Supernumerary Teeth. Supernumerary Teeth. Steven R. Singer, DDS 212.305.5674 srs2@columbia.
Anatomic Anomalies Steven R. Singer, DDS 212.305.5674 [email protected] Anomalies! Anomalies are variations in the:! Size! Morphology! Number! Eruption of the teeth Anomalies Anomalies There are two categories:!
Treatment planning for the class 0, 1A, 1B dental arches
Treatment planning for the class 0, 1A, 1B dental arches Dr.. Peter Hermann Dr Reminder: Torquing movement on tooth supported denture : no movement Class 1 movement in one direction (depression) Class
Electrical tests on PCB insulation materials and investigation of influence of solder fillets geometry on partial discharge
, Firenze, Italy Electrical tests on PCB insulation materials and investigation of influence of solder fillets geometry on partial discharge A. Bulletti, L. Capineri B. Dunn ESTEC Material and Process
Impact Echo Scanning Technology for Internal Grout Condition Evaluation in Post-Tensioned Bridge Ducts
Impact Echo Scanning Technology for Internal Grout Condition Evaluation in Post-Tensioned Bridge Ducts Yajai Tinkey, Ph.D. Olson Engineering, Wheat Ridge, Colorado Larry D. Olson, P.E. Olson Engineering,
CHAPTER 12 SURVEY LINES. portion of the tooth is undercut to the path of placement of the denture. DEFINITIONS
CHAPTER 12 portion of the tooth is undercut to the path of placement of the denture. SURVEY LINES DEFINITIONS A SURVEY LINE is a line produced on a cast by a surveyor or scribe marking the greatest prominence
ENS 07 Paris, France, 3-4 December 2007
ENS 7 Paris, France, 3-4 December 7 FRICTION DRIVE SIMULATION OF A SURFACE ACOUSTIC WAVE MOTOR BY NANO VIBRATION Minoru Kuribayashi Kurosawa, Takashi Shigematsu Tokyou Institute of Technology, Yokohama
APPLICATION OF PHOTOGRAPHY IN DENTAL PRACTICE
Journal of IMAB ISSN: 1312-773X http://www.journal-imab-bg.org http://dx.doi.org/10.5272/jimab.2015211.682 Journal of IMAB - Annual Proceeding (Scientific Papers) 2015, vol. 21, issue 1 APPLICATION OF
The American Board of Orthodontics (ABO) Digital Model Requirements Original Release 04.23.2013 Last Update 03.26.2015
Page 1 of 7 The American Board of Orthodontics (ABO) Digital Model Requirements Original Release 04.23.2013 Last Update 03.26.2015 Introduction In order to provide access to board certification for all
EXPERIMENTAL ERROR AND DATA ANALYSIS
EXPERIMENTAL ERROR AND DATA ANALYSIS 1. INTRODUCTION: Laboratory experiments involve taking measurements of physical quantities. No measurement of any physical quantity is ever perfectly accurate, except
Classification of Malocclusion
Classification of Malocclusion What s going on here? How would you describe this? Dr. Robert Gallois REFERENCE: Where Do We Begin? ESSENTIALS FOR ORTHODONTIC PRACTICE By Riolo and Avery Chapter 6 pages
DENTAL FOR EVERYONE SUMMARY OF BENEFITS, LIMITATIONS AND EXCLUSIONS
DENTAL FOR EVERYONE SUMMARY OF BENEFITS, LIMITATIONS AND EXCLUSIONS DEDUCTIBLE The dental plan features a deductible. This is an amount the Enrollee must pay out-of-pocket before Benefits are paid. The
Removing fixed prostheses using the ATD automatic crown and bridge remover
Removing fixed prostheses using the ATD automatic crown and bridge remover By Dr. Ian E. Shuman, Baltimore, MD. Information provided by J. Morita USA When removing cemented provisionals and final fixed
http://eprints.gla.ac.uk/5255/ Deposited on: 8 June 2009
e Talal, A and Tanner, K.E. and Billington, R. and Pearson, G.J. (28) Effect of ultrasound on the setting characteristics of glass ionomer cements studied by Fourier Transform Infrared Spectroscopy. Journal
Orthodontic mini-implants, or temporary anchorage devices
Anchors, away by John Marshall Grady, DMD, Dan E. Kastner, DMD, and Matthew C. Gornick, DMD Drs. John Marshall Grady (center), Dan E. Kastner (left), and Matthew C. Gornick (right). Drs. John Marshall
Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm
Progress In Electromagnetics Research Symposium Proceedings, Taipei, March 5 8, 3 359 Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm Yoshito Sonoda, Takashi Samatsu, and
Polarization of Light
Polarization of Light References Halliday/Resnick/Walker Fundamentals of Physics, Chapter 33, 7 th ed. Wiley 005 PASCO EX997A and EX999 guide sheets (written by Ann Hanks) weight Exercises and weights
Increasing. VDO and the Use of CAD/CAM. Prosthodontic Principles and the Full-Mouth Reconstruction. 86 Summer 2013 Volume 29 Number 2
Increasing VDO and the Use of CAD/CAM Prosthodontic Principles and the Full-Mouth Reconstruction Jonathan L. Ferencz, DDS, FACP Abstract This article describes the treatment of a young adult female with
Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.
Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment. Dr. med. dent. David McFadden, Dallas County, USA Initial situation (single X-ray) Tooth 16
Step-by-Step Virtual Implant Planning MIS Corporation. All Rights Reserved. MIS Warranty: MIS exercises great care and effort in maintaining the superior quality of its products. All MIS products are guaranteed
v = fλ PROGRESSIVE WAVES 1 Candidates should be able to :
PROGRESSIVE WAVES 1 Candidates should be able to : Describe and distinguish between progressive longitudinal and transverse waves. With the exception of electromagnetic waves, which do not need a material
Advanced MRI methods in diagnostics of spinal cord pathology
Advanced MRI methods in diagnostics of spinal cord pathology Stanisław Kwieciński Department of Magnetic Resonance MR IMAGING LAB MRI /MRS IN BIOMEDICAL RESEARCH ON HUMANS AND ANIMAL MODELS IN VIVO Equipment:
ULTRASONIC SIZING OF CRACKS IN WEB GEOMETRIES. T. A. Gray and R. B. Thompson. Ames Laboratory, USDOE Iowa State University Ames, IA 50011 INTRODUCTION
ULTRASONIC SIZING OF CRACKS IN WEB GEOMETRIES T. A. Gray and R. B. Thompson Ames Laboratory, USDOE Iowa State University Ames, IA 50011 INTRODUCTION Evaluation of the critical nature of interior cracks
Jacket crown. Advantage : Crown and Bridge
Crown and Bridge Lecture 1 Dr.Nibras AL-Kuraine Jacket crown It is a type of crown that is formed by a tooth colored material. It is mainly used as a single unit in the anterior quadrant of the mouth.