Power Quality Solutions and Energy Savings What is Real?
|
|
|
- Natalie Morrison
- 10 years ago
- Views:
Transcription
1 ABSTRACT One of the most significant changes in the Power Quality industry in the past five years is the method of selling Power Quality solutions. Originally, Power Quality solutions were sold as an insurance policy to avoid potential damage from power disturbances such as transients, voltage sags, interruptions or harmonics. Today, many Power Quality solution providers have found it more effective to promote energy cost reduction associated with their products rather than to deal with the soft savings associated with minimizing downtime or reducing damage to electrical equipment. The problem is that some of these solutions providers have significantly overstated the savings and the customers are deceived. While these solutions provide excellent protection, they often provide very little, if any, energy savings. This paper will discuss work being done to evaluate the actual savings expected from various Power Quality solutions and will give some guidance as to the selection of these solutions based on energy savings.
2 Introduction Everyone wants to save energy and why not? With the cost of energy rising at unprecedented rates, even a small amount of savings can be a significant amount of money. The problem is that in most cases, the low hanging fruit has already been picked. This leaves the door open to new/alternative energy saving devices. One category of devices that claims to save energy is Power Quality (PQ) solutions. Several types PQ devices claim to save energy some more than others. The amount of savings available from these devices appears to be directly proportional to the mystique of the device and the passion of the salesperson representing the product. Some of the black-box PQ solutions available today apparently correct all known PQ problems while reducing energy costs by 10-30%. With a savings like that, why wouldn t a controller consider these solutions? While most reputable manufacturer and consultants can quickly see through the black smoke, some of the not-so-obvious techniques are running rampant and getting through to end users (commercial, industrial and even residential) tarnishing the reputation of the entire industry. It is said that any good lie has an element of truth about it. Many Power Quality solutions that are promoted as energy saving devices actually do save energy, but the claims for the savings are greatly exaggerated, where the actual savings would be far less than the stated value. Short of turning off loads or a wholesale change in the type of loads used (lighting fixtures, for example), it is nearly impossible to save the 20-30% stated by some of these vendors. This problem is expected to worsen as the current energy crisis is likely to result in intensified interest in energy conservation techniques. Why is it that this is a new technique in selling? It capitalizes on the reduction in technical staffing at most facilities evaluating solutions, and relies on the complicated nature of PQ solutions. It also fits well with the need to demonstrate a short capital payback period that is required by most companies today. Capital budgets are hard to come by and having a solution that shows a real payback in two years or less is an easy sell. Power Quality solutions have historically been sold as insurance policies to protect against the next damaging sag, surge or interruption without guarantee of the number of times where the benefits are hard to qualify. By contrast energy savings offers easy justification. In addition to these overstated claims, many times these so-called all-in-one solutions may solve one problem but tend to exacerbate another. They are applied without consideration for the system as a whole. For example, some black-box solutions correct power factor using standard low voltage capacitors but may do so without regard to potential overvoltage concerns or harmonic resonance considerations. This paper summarizes the authors experiences with several of these equipment suppliers and the sales methods that they use to confuse the end users enough to close a sale. Power Quality and Energy Conservation Power Quality and energy conservation are topics that are often commingled in papers and conferences such as this conference. Generally, there are two reasons for this: most times, loads used to conserve energy for example adjustable speed drives and compact fluorescent lights impact Power Quality. Secondly, energy conservation and Power Quality often involve end user concerns where electric utilities or the government take a leadership role in promoting new technologies or mandating technologies. Because these topics are often considered together, there is opportunity for confusion and misleading information regarding energy savings. There are generally two categories of Power Quality solutions that claim to save energy: PF Correction Equipment Black/green boxes with capacitors in them PF correction capacitors Harmonic filters Other PQ Solutions Negative sequence current reduction Neutral blocking filter Surge protection Soft starters Zig-zag reactors Harmonic mitigating transformers (HMT) Conservation voltage reduction (CVR) equipment Green plug The first category, Power Factor (PF) Correction Equipment, includes the most common solutions that provide real opportunities for savings. These solutions can provide energy bill savings and some of the opportunities are significant but the actual savings result from reduction in penalties, not real kw or kwh savings, generally. The second group, Other PQ Solutions, generally offers much less or no real savings but these are often promoted as significant savings in an effort to have a quick payback and return on investment (ROI). Energy That Is Wasted You can only save energy that is wasted. The Electric Power Research Institute (EPRI) has evaluated many of the claims of potential energy savings devices and has presented many times on the potential of energy savings and Power Quality. They make the seemingly obvious observation that You can only save energy that is wasted, [3] meaning that power required to do work cannot be eliminated from your electric bill not matter what you do short of applying a generator or source of energy locally. This statement is especially appropriate with the PQ solutions that claim to save energy. If a device saves all of the potential energy on a power system that it could, it can only save the energy that is wasted in losses throughout the system. Therefore, with typical system losses on the order of 1-4%, devices that eliminate these losses, at best, can only reduce your bill by 1-4%. Obviously, energy conservation methods (turning off the lights) and purchasing loads that require less work/ energy (compact fluorescent lights) are very valid methods of saving real kw on your energy bill. 2
3 Industry Application IA E PF Correction and Your Utility Bill Can capacitors and other PF solutions help you save a significant amount of money on your utility bill? Absolutely IF you have a power factor penalty you can save on the order of 10-30% of your electric bill and have a 1-2 year payback! However, not every utility company charges a penalty for poor power factor. How would you know if you are paying a penalty? It is not the intention of this paper to discuss power factor penalties in detail but rather to discuss the relationship between PQ and energy savings. This section of the paper simply presents an overview of power factor considerations so that the reader will have a basis to investigate their utility bill considering power factor penalties. Table 1 [12] shows a number of different types of power factor penalties. Most are straightforward and can be analyzed by engineers and end users to help determine how to reduce power factor penalties. Sometimes utilities will incorporate multiple methods of billing for low power factor, so several of the penalties in Table 1 may be applied. Sometimes a power factor penalty is somewhat hidden. For example, in a straight kva demand rate there is nothing that explicitly mentions a power factor penalty. But a poor power factor will result in a higher kva for a given kw of load, so there is an implicit power factor penalty built into that rate. In other cases the utility may give a rebate for maintaining a power factor above a given level. At a glance you might not think you are paying a penalty if you do not get this rebate, but you would be leaving money on the table if you did not take advantage of the rebate. It is functionally equivalent to a power factor penalty, just phrased differently. Many customers receive billing through the local municipality or Co-op. The power factor penalty may be levied by the power supplier to the Co-op and the penalty adjusted in the demand charge. It may look like a reduction in kw when the penalty is removed. Again, all of these savings are based on the premise that the utility company charges a penalty. If not, it is still possible to save money but usually an order of magnitude less than with a penalty. Confusion Created by Sales Methods Various sales methods are used in order to promote the savings involved with applying PQ solutions. One of the methods is to claim significant benefits associated with the equipment related to the payback. Many are so called hard-savings but many are softsavings that are associated with or a side benefit of the solution. Many of these are real savings but often significantly overstated. Hard-savings include: Reduced energy (kwh) usage Demand reduction (kw) Improved PF Reduction in taxes Reduction in I 2 R in conductors Reduction in equipment losses (motors, transformers, etc.) Operating cost reduction Soft savings include: Reactive power savings (kvar)* Apparent power savings (kva)* Lengthens electrical equipment life Enhances electrical equipment life Improves performance of equipment Protects sensitive electronic equipment Reduces equipment replacement parts Reduces required maintenance Space savings Don t have to oversize equipment (generators, etc.) Less HVAC required to remove heat Protects the environment by reducing generation, emissions and waste Improves safety * May be hard or soft savings depending upon billing structure of the utility company Other PQ solution providers use one or combinations of the following energy savings selling techniques: A method that some salesman use or publicize in promotional marketing literature is to call upon stated industry experts or customer testimonies to sell the product. Giving third party accreditation (universities, government bodies, experts, newspaper articles, internet site, etc.) lends credence to a sales story. While most of these methods are credible methods of selling, in the context of promoting energy savings for PQ solutions these methods present a dilemma for the end customer and they are often frightened or embarrassed into purchasing the solution. References from sources such as the Department of Energy (DOE), Green Buildings, the US President (Executive Orders), FEMP and Energy Star carry significant weight in selling credibility. In addition, claims that the solution will make them a hero to their boss are often hard to dismiss and ignore. Sometimes seeing the name of a close competitor on a customer list provided by a PQ solution provider is incentive enough to believe the claims and move forward with using the product. Confusing percentages You can actually reduce the losses in a transformer and make your system more efficient by replacing a transformer with 97% efficiency with a transformer with 97.8% efficiency (true statement). This is a 0.8% increase in efficiency but you could also claim that you have reduced your losses by 27%! Saving 20-30% of losses (when the losses are 2.2% to 3.0% of the full load of the transformer) is not equal to saving 20-30% of the total energy used by the load. Faulty or questionable measurement and verification (M&V) In many instances, these products are sold based upon hard-toprove claims that are difficult to dispute. The measurement and verification methods can contribute to the ambiguity and confusion. 3
4 Inferences and overgeneralizations from similar measurements assumptions are made regarding the potential and actual savings that will result at a site without actually measuring the results. The power system components or the actual PQ solution may not exhibit the savings that are claimed. This is especially true for PF penalty savings. For example, just because the product saved 12% in Alaska doesn t mean that it will save the same amount in New York. As with any good marketing program, these vendors will only show the situations where customers saved significant money versus the many others who had little or no savings. Revenue grade metering without using revenue grade metering (including CT s and PT s, where applicable), small inaccuracies in measurements can translate to large overstated claims. Especially under conditions where the load on a transformer, for example, is much less than 50% (a typical situation). This means that the difference in current or kw with and without the corrective equipment may be less than 1% of the full load capability. For example, if the load on a 75 kva transformer is 15.1 kw and the measured load with the corrective equipment in service is 14.7 kw, this 400 W difference may seem significant but may be partially due to phase shift errors in the CT s especially when harmonic currents are involved. CT inaccuracies low quality CT s or light loading on the system may yield phase angle errors that will contribute to PF difference and could translate into kw differences. This difference may yield false positive results between conditions where PQ equipment is installed and tested versus when it is out of the circuit. Lack of a practical method of showing the equipment in the circuit versus out of the circuit many times, if the PQ equipment is connected in series with the load, there is not an easy method of showing the equipment in the circuit and then immediately out of the circuit (unless the equipment has a bypass switch). Therefore, it is very difficult to insure that the loading has not changed or some other important variable like ambient temperature has not altered the results and consequently, the measurements during the time it takes to add or remove the equipment for testing. Inappropriate measurement duration taking a single snapshot or averaging a very long measurement are both opportunities to hide the truth in the numbers. The method that results in the highest proven savings is usually used regardless if, in reality, the savings are actually realized. Hard to prove or disprove guarantees One method of selling this equipment that has been successful (unfortunately for the end user) is locking in the sale of the PQ vendor s equipment only with a guarantee of energy savings. This pseudo performance contract sale means that the end user must purchase only the PQ supplier s equipment and not only that, usually, the PQ vendor insists that the end user must install the PQ solution at every possible location for savings. Basically, it works like this: end user XYZ purchases a system of black box solutions from the PQ vendor and the system consists of one piece per distribution panel in the factory. In the end, the end user purchases 35 pieces of equipment with the promise of energy savings for the installed system solution. The catch in the guarantee is that the PQ vendor requires a substantial effort from the end user to prove that energy was not saved. The PQ vendor will only pay the difference in the cost of the total installed equipment minus any savings that the end user can prove were NOT saved as a result of the installation of the PQ equipment! In the absolute worst case (for the PQ vendor), they lose their cost of the supplied equipment but it infrequently comes to this. To further complicate things, there are substantial data requirements left as a burden to the end user to determine (typically over a period of two or more years). The end user must research temperature and humidity information, electrical parameters of the loads and other difficult to find information in order to disprove any savings. Most customers simply either accept the savings as real (unfortunately) or write off the money spent on the solution and move on. Finally, many of the guarantees are stated as guaranteed energy savings of up to some excessive value, for example, up to 35%, when in reality the actual savings for 99.9% of all facilities is much less than 5%. The Safety Card If the PQ vendor has a marginally believable story regarding the actual versus potential energy savings, they may bring up enhanced safety as icing on the cake. Unfortunately, once the topic of safety is introduced, some managers feel compelled (or more likely trapped) into purchasing the equipment. Safety solutions basically eliminate the need for proving the payback. The use of kva versus kw is an easy method for a rep to make claims of significant improvement without having to lie. Equipment that corrects the power factor is capable of significantly improving the kva but has minimal effect on kw. It is not unrealistic to see a 20% savings in kva for a poor power factor load but the actual energy savings is much less than 5%. Unfortunately, a majority of the US utility companies bill on kwh and kw demand. Simple power factor correction methods (including harmonic filters) are generally the least expensive and practical method of improving the power factor for those instances where kva rates are enforced. Most often, it is simply the passion of the rep selling the equipment that lends credibility to the energy savings story. Many times, non-technical representatives are recruited to sell these products. To further complicate things, unless the rep is an engineer and fully understands the claimed savings, they may not realize that they are selling snake oil and they believe the seemingly credible training and promotional information of the product manufacturer. The authors have actually been told by one of these passionate reps, You are thinking like an engineer it is likely that you won t understand how the savings works it s almost like you are too smart to understand! How do you respond to that statement? If the end user is not technical (ideal for the PQ vendor/rep), the PQ vendor may show apparent savings at a location in the customer s facility and then ask their most senior technical guy sign off on the savings. Especially in the case of kva savings from PF correction, this is a relatively simple opportunity for confusing sales techniques. Once the technical sign off has occurred, the PQ vendor takes the opportunity to tell the end user that the equipment will offer very similar savings at all of the proposed locations in the plant. They often then move to the controller or financial person responsible for paying the bills with the technical sign off in hand. This limits the selling effort to the most probable and easiest to prove location in the facility, usually a small lightly loaded motor where power factor correction is a natural opportunity. For these shameless companies, as soon as they determine that you know Ohm s Law, they pack up and move on to the next customer. 4
5 Industry Application IA E Solutions That Claim to Save Energy Below are several Power Quality related solutions that have either a primary or secondary claim of energy savings. A short paragraph with each item describes the claimed savings and details of why the claims are likely overstated. Table 2 summarizes each solution with the claimed energy savings and the actual expected savings along with summary comments regarding the potential reasons for discrepancies. Black Box All-in-One Solutions Description: These magical boxes are all-in-one solutions that claim to reduce your power bill by improving voltage balance, reducing transients and improving power factor. Some of these units are passive components (surge suppressors, capacitors, balancing reactors, harmonic filters) and some have power electronic components for voltage and current conditioning. The descriptions are very vague and difficult to understand for typical end users. Often times, these black boxes are painted green which apparently helps with the energy savings. Unfortunately, lately these companies have begun to prey on unsuspecting residential customers. These customers have little to no chance of understanding what they have purchased but are typically desperate to save money on any energy bills with fuel prices at all time highs. Stated/Claimed Savings or Payback: Up to 35% energy savings. Actual/Realistic Range of Payback: Some of the claims are somewhat true but largely overstated. See surge protection, PF correction, harmonic solutions and unbalanced voltage solutions for descriptions of components. Unless the utility company imposes a PF penalty, realistic energy savings of less than 3% are typical. Residential customers actually save little or no energy because they install these boxes, usually containing a small PF correction capacitor, at their main service. Savings created by capacitors only impact the losses on the upstream feeders saving a small amount of energy for the utility (in losses through the service transformer) but saving the customer nothing. Backup Information (test lab, papers, etc.): See Unbalanced Voltage Solutions, PF Correction, Harmonic Solutions and Surge Protection Harmonic Filters and Power Factor Correction Description: A manufacturer of harmonic filters claims that their filter reduces currents and harmonic energy losses in the main transformer, resulting in significant energy savings to the facility. Stated/Claimed Savings or Payback: Reduces energy consumption significantly, by several percentage points of the current energy consumption. The claim points out that the currents in the transformer are reduced significantly, and that harmonic heating in the transformer is reduced significantly. It points out that eddy-current related loss in the transformer is proportional to the square of the frequency. Actual/Realistic Range of Payback: The harmonic filter does reduce 60Hz fundamental current in the transformer, which is the same benefit as ordinary power factor correction. However these savings are much less than 1% of the energy load. Products that Reduce Negative Sequence Currents in Motors Description: Voltage unbalance or negative sequence voltage harmonics (i.e. 2nd or 5th harmonic, typically) cause the rotor of an induction motor to resist its normal rotation. This resistance causes inefficient operation in the motor, vibrations and heat that may cause premature failure. Linear loads (motors) will draw a non-linear current with components of current proportional to the voltage distortion. 60 Hz Rotation 5th Harmonic Rotation Figure 1. Negative Sequence Current and Motors Stated/Claimed Savings or Payback: Improved motor efficiency and reduced failures by > 10%. Actual/Realistic Range of Payback: Claims are primarily true but typically overstated. Unbalanced currents caused by unbalanced voltages, (see NEMA MG-1), are often 6 or more times the unbalanced voltage percentage. Therefore, the system will have more I 2 R losses than with balanced voltages and currents. In addition, negative sequence harmonics, primarily 5th harmonic, causes an opposing force to the positive sequence (60 Hz) rotation. This is like driving with your foot on the brake while you are moving forward with your foot on the gas to overcome the brake resistance. It creates system losses, heat and premature failure but realistic savings is on the order of 2% or less. Backup Information (test lab, papers, etc.): Reference [1], Reference [2] (Balancing) Zig-Zag Reactors Description: Zig-zag reactors have the effect of balancing voltages and canceling some harmonic current and reactive current from the loads. In general, under unbalanced voltage conditions, they reduce overall current flow from the load and can reduce I 2 R losses upstream. When these devices are connected in series with the load, it changes the way power is drawn from the sources. It is often difficult to measure before and after installation (unless a bypass is available) to show savings under constant load conditions. Stated/Claimed Savings or Payback: Up to 20% energy savings Actual/Realistic Range of Payback: I 2 R loss savings could be up to several percent. This particular device requires very highly calibrated equipment and CT s to measure savings since much of the difference with and without the equipment is shown via a PF benefit and reduction in upstream losses. Interestingly, sometimes a small amount of kw is saved when these devices are installed and sometimes a small amount of kw is lost when they are installed. Surge Suppressors Description: Surge protectors (transient voltage surge suppressors TVSS or surge protective devices SPD) equipment is installed at various locations throughout the facility to reduce damaging transients that waste energy. Claim is that transients cause heat that wastes energy. Statements like, every time you type on your typewriter, you create micro transients that waste energy.. are made and confuse non-technical end users. Stated/Claimed Savings or Payback: Up to 20% energy savings if installed at all recommended locations. Actual/Realistic Range of Payback: None, nothing, zero, 0.000%. Backup Information (test lab, papers, etc.): Reference [7] and many Internet links including federal websites. 5
6 Harmonic Mitigating Transformers (HMT s) Description: HMT s are phase shifting transformers of various configurations (wye/zig-zag, delta/zig-zag, etc.) that allow recirculation of third harmonic currents on the secondary of the transformer (instead of allowing them to flow into the delta windings and cause additional losses in the transformer and upstream). They are typically low loss (winding and core) transformers and inherently save energy versus standard transformers. They are often used in pairs or multiple sets for higher order harmonic cancellation (5th, 7th, 11th, 13, etc.). In this way, they eliminate the harmonic currents upstream of the transformer(s) and reduce I 2 R losses. Stated/Claimed Savings or Payback: Up to 20% energy savings versus standard transformers or loss reduction of 30%. Actual/Realistic Range of Payback: Loss reduction is possible (based on example given earlier) but 30% loss reduction may equal 1-2% or so of actual energy savings (or points of efficiency). With transformer designs (lower winding core losses) and harmonic reduction, improvements of 5% are possible. In ideal conditions, 8-10% energy savings are possible but very rare. Still, these devices will considerably improve the Power Quality of the system and over a year life, these transformers will pay for themselves in savings 6-8 times with no maintenance. So, although they don t have a 2 year payback, these transformers are considered a very good investment. Backup Information (test lab, papers, etc.): Reference [4], Reference [5]. Neutral Blocking Filters Description: A 3rd harmonic high impedance blocking filter is inserted in the neutral connection of a 120/208 V transformer. This impedance does not allow 3rd harmonic current to flow in the neutral, thus, effectively eliminating it in the phase conductors and in the load. It is most effective in situations where a significant number of single-phase switch mode power supplies are installed. This reduces the rms current throughout the system and is unique in that it eliminates 3rd harmonics upstream and downstream. Stated/Claimed Savings or Payback: Up to 8% energy savings Actual/Realistic Range of Payback: Claims are true but are typically less (1-3%) depending on load mix. Backup Information (test lab, papers, etc.): Reference [4], Reference [5] Soft Starters Description: Many people believe that the use of soft starters will reduce the peak demand on their energy bill and many (unknowing) salesmen sell this benefit. Generally, we believe that it is an innocent oversight based on the lack of understanding of the salesman or end user but sometimes the salesman knows better. Stated/Claimed Savings or Payback: Reduces peak demand and reduces kw billing by a certain amount depending on the size of the motor versus the total load. Actual/Realistic Range of Payback: Soft starters reduce the peak draw of (primarily reactive) current during a motor starting condition that typically lasts 3-10 seconds. This short period is a small fraction of 15 minute average demand window where the utility records peak demand. Soft starters are useful for reducing the voltage drop caused by large inrush currents to motors during the starting condition but do not save energy or demand. Conservation Voltage Reduction (CVR) Products Description: For years, electric utility companies have practiced voltage reduction, often called brownouts to reduce load on their power system. The thought was that constant impedance loads would draw less current and, thus, less power. Simply stated, for many lighting loads (i.e. residential), this is true but it also results in lower light intensity, perhaps below acceptable levels. For other constant impedance loads that require a certain amount of heat generated (i.e. electric dryer, hot water tank, heater, etc.) the load may draw less kw instantly but will require longer thermal cycles to achieve the goal of heating or drying. For constant power (i.e. motor) loads, there is no savings benefit because if the voltage goes down, the current goes up. Also, from a utility point of view this increased current translates into a need to provide increased reactive power. On a stressed utility line, finding sufficient vars is a problem. As a result, the action of reducing the voltage in this condition only exacerbates the problem. The concept of CVR has been instituted into electronic and magnetic component LV designs that are installed with the promise of significant energy savings. Stated/Claimed Savings or Payback: 3-13% of energy and demand Actual/Realistic Range of Payback: < 2% on aggregate systems (i.e. multiple types of loads) and up to 13% in rare cases on a specific load. Typically cost per load installing it on a specific piece of equipment may be more economical building into the equipment or by using fixed tap regulation. Backup Information (test lab, papers, etc.): Reference [3] and many sources on the Internet. Energy Saver Plug Confusion in the evaluation of energy savings projects is not limited to industrial facility managers. The Canadian Office of Energy Efficiency provided cash awards to university student projects related to energy efficiency specifically, how using energy wisely reduces greenhouse gas emissions that contribute to climate change. A 2005 award went to a project promoting the use of The Green Plug. The project website [9] has this amazing text: The actual savings available through the green plug are difficult to measure, he added. But he estimated that power producers could expect to experience a drop of percent in power and energy consumption if the green plug is used extensively. Wow! That s something. No wonder the project won an award. But what is this green plug? The Green Plug was invented by my thesis advisor, Dr. A.M. Sharaf, said René. It s really a Modulated Switched Dynamic Filter Capacitor Compensator, a device designed to make existing power systems more powerful and energy efficient by reducing the amount of reactive energy and harmonic currents that are generated by electrical residential and commercial loads. Oops, we ve heard some of this before. The beauty of the green plug is that it is hard to understand, and hard to measure the savings. But does it actually save significant energy? The troubling part of it is that the claims are reductions of reactive power and harmonic energy. It is hard to believe the energy savings are nearly as significant as claimed. 6
7 Industry Application IA E Authors Viewpoint We have done the calculations. We have done the measurements. We have talked to the vendors. We simply do not believe the excessive claims of real energy savings with PQ solutions. Can you save significant money with PF correction? Yes, IF there is a penalty. The authors strongly believe in the reliability improvements offered by well designed PQ solutions. However, we offer the information in this paper so that the reader can fairly evaluate these solutions for what they are instead of based on the energy they save. Power Quality Lab A Power Quality Laboratory was designed and built near Pittsburgh, Pennsylvania. This lab has become the ideal setting for testing and evaluating PQ solutions especially as they relate to energy savings. The Power Quality Lab is a major component in an 8000 square foot demonstration and test facility/experience Center ( com/eatoncom/markets/electrical/servicessupport/experience/ index.htm) where most of these solutions mentioned in this paper have been evaluated. The authors can confidently state that the information presented in this paper is an unbiased evaluation of these solutions. Future work in the PQ Lab will include further testing and optimization of energy saving solutions for industrial, commercial, data center and residential applications. Many Power Quality solutions have been tested in the PQ Lab over the past two years. These include capacitive devices, harmonic filters, surge protectors and black box combination solutions. In addition, tests have been performed on Harmonic Mitigating Transformers (HMT) and UPS solutions in an effort to determine what opportunities exist for energy savings based on design and harmonic loading. The graphs below summarize some of the results of these tests indicating realistic savings. Figure 2 shows the results of a test where a 75 kva transformer was subjected to 100% linear, resistive load and then to 100% harmonic load (computer power supplies). This figure clearly shows that transformer losses, in this case, increased loading by 1% across the loading of the transformer. This clearly indicates that there are some savings available by reducing harmonic currents on the power system. Figure 3 shows a comparison of various transformer types subjected to 100% harmonic load. Note the significant difference between the losses in an energy efficient (TP-1) and K-rated transformer versus a Harmonic Mitigating Transformer. These tests also indicate that there is a significant savings associated with the use of HMT transformers. Again, the savings are not 25% of the total load as some vendors may advertise but they are a steady 1-3% and will easily pay for the transformer many times over the life of the transformer. The infrascan in Figure 4 shows the thermal stress of harmonic heating on a standard transformer versus a HMT subjected to 100% harmonic load relating design to transformer losses. % Efficiency 99.00% 98.50% 98.00% 97.50% 97.00% 96.50% 96.00% 95.50% 95.00% 94.50% 15% 25% 35% 50% 75% 100% HMT 97.85% 98.41% 98.51% 98.40% 98.08% 97.70% TP % 98.13% 98.18% 98.01% 97.63% 97.00% K % 96.29% 96.81% 97.09% 96.98% 96.64% Loading Level Figure 3. Efficiency Curves for 75 kva Family of Transformers under 100% Harmonic Load Transformer Efficiency - 75 kva Example Figure 4. Infrascan of Standard TP-1 Transformer vs. HMT with 100% Harmonic Load % Load Resistive Load 100% Harmonic Load Figure 2. Transformer Losses with 100% Resistive Load and 100% Harmonic Loads 7
8 Figure 5 illustrates testing and modeling results of a power system where PF capacitors were applied illustrating the savings achievable versus kvar compensation. % kw Savings 1.8% 1.6% 1.4% 1.2% 1.0% 0.8% 0.6% 0.4% 0.2% 0.0% Figure 5. Loss Savings Opportunity using PF Correction Capacitors Conclusions Buyer beware if it sounds too good to be true, it probably is! There are many opportunities to save money by applying Power Quality solutions by improving reliability. Many of these solutions provide some energy savings and other savings opportunities beyond their primary intention. However, it is important to recognize some of the significantly overstated marketing claims by manufacturers. The energy savings claims are often overstated by an order of magnitude (10X) or more. The intention of this paper was not to argue the detailed technical aspects of each solution, per se, but rather to point out the pitfalls in believing the information publicized regarding these types of equipment. In addition, this paper was assembled in an attempt to show the dramatic change in sales methods for Power Quality solutions over the past several years. References Loss Improvement kvar [1] Ching-Yin Lee, Wei-Jen Len, Yen-Nien Wang and Jyh-Cheng Gu, Effects of Voltage Harmonics on the Electrical and Mechanical Performance of a Three-phase Induction Motor, IEEE, [2] National Electric Manufacturer s Association (NEMA) Motor and Generator Standard (MG-1), [3] Arshad Mansoor and Roger Dugan, Energy Savings: You Can Only Save Energy That is Wasted, Sept [4] Carnovale, Daniel J., Price and Performance Considerations for Harmonic Solutions. Power Quality Conference 2003, Chicago, IL. [5] J. Piel and D. Carnovale, Economic and Electrical Benefits of Harmonic Reduction Methods in Commercial Facilities, EPRI Power Quality Conference (PQA), 2003, Monterey, CA. [6] Alexander E. Emanuel, True and False Energy-Savings Devices, in IEEE Transactions on Industry Applications, Vol 33, No. 6, November/December [7] Mike Holt Newsletters Online, TVSS Claims Energy Savings Update TVSS_Claims_Energy_Savings_-_Update_ htm [8] Mark McGranaghan, Can Power Factor Correction Save Energy?, Power Quality Assurance Magazine [9] the-green-plug.cfm?attr=0 [10] Dan Carnovale, David Mueller, Power Quality Solutions and Energy Savings, 2005 Power Quality Conference and Exhibition. [11] Bill Howe, Electric Power Research Institute Strategies for Evaluating Black Box Technologies, Power Point Presentation. [12] Blooming, Thomas and Carnovale, Daniel, Capacitor Application Issues, in IEEE Transactions on Industry Applications, Vol 44, Issue 4, July/August Authors Biographies Daniel J. Carnovale, P.E. is the Power Quality Solutions Manager for Eaton s Electrical Group. Dan is responsible for developing strategies and tools for reliability and productivity solutions across the Electrical Group s eight equipment divisions and Engineering Services group. Dan has developed Eaton s Power Systems Experience Center and Lab, a one-of-a-kind facility where PQ problems are created and mitigated for demonstration and testing purposes. He has developed and teaches CEU-certified technical seminars on Power Systems and Power System Analysis. Dan has conducted several hundred Power Quality site investigations for commercial, industrial and utility power systems: evaluating PQ issues and applying solutions. Dan worked for Westinghouse Engineering Services and ABB Power T&D. He received his B.S. Degree in Electrical Engineering from Gannon University, his M.S. Degree in Power Systems from Rensselaer Polytechnic Institute and an MBA from Robert Morris University. He is a registered Professional Engineer in the states of Pennsylvania, California and Alaska and a Certified Energy Manager (CEM). He can be contacted at [email protected]. Timothy J. Hronek. P.E. /CEM is an Energy Engineer within Eaton s Electrical Group. Hronek has more than 20 years of experience in engineering design, energy audits, marketing and business development, and has a major role in the delivery of Eaton s PowerChain Management solutions to help its customers develop sustainability programs, education, greenhouse gas reduction, and reduce operating energy costs. Hronek authored and implemented Eaton Corporation s energy management training program and serves as consultant for Eaton Corporation s comprehensive green house gas reduction and energy efficiency programs. Hronek is a licensed Professional Engineer in the States of Maryland, Ohio, and Pennsylvania, and a Certified Energy Manager (CEM). He holds a Bachelor of Mechanical Engineering from The University of Akron. He can be contacted at [email protected]. 8
9 Industry Application IA E Table 1. Power Factor Penalties Rate Type Description of PF Penalty Example kva (demand) rates PF (kva) adjustment PF ratio (kw demand) adjustment PF magnitude (kw demand) adjustment PF multiplier (PFM) kvar demand charge Penalty for < 1.0 pf; generally applied as a $/kva When the pf is less than X%, the demand may be taken as X% of the measured kva If the pf is < X%, the demand will be adjusted by the following: X%/actual pf * actual demand = adjusted demand. PF adjustment increases or decreases the net (kw) demand charge X% for each Y% the pf is above or below the utility specified pf Demand is increased (or decreased) by a calculated multiplier determined by a utility table or by a formula $X per kva of reactive demand in excess of Y% of the kw demand Demand = 800 kw; pf=80%; kva=1000; demand charge = $10/kVA pf penalty = ( )*$10 = $2000/month When the pf is less than 90%, the demand may be taken as 90% of the measured kva pf=80%; kva=1000; demand charge = $10/kVA Billed demand = 0.90*1000 = 900 kw pf penalty = ( *0.80)*$10 = $1000/month If the pf is < 85%, the demand will be adjusted by the following: 85%/actual pf * actual demand = adjusted demand. Demand = 800 kw; pf=80% demand charge = $10/kW Adjusted demand = (0.85/0.80)*800=850kW pf penalty = ( )*$10 = $500/month; Where the pf is < 85%, the net demand charges shall be increased 1% for each whole 1% the pf is < 90%; likewise, where the pf is higher than 95%, the demand charges will be reduced by 1% for each whole 1% the pf is above 90%. Demand = 800 kw; pf=80%; demand charge = $10/kW Up to 90%, demand adjustment = 800*10%=80kW (from 80% to 90%) = net demand of 880 kw If pf is corrected to 1.0, pf adjustment (reduction) = 800*10%=80kW (from 90%-100%) = net demand of 720kW Correcting pf from 80% to 100%, potential net savings is ( )*$10/kW = $1600/month Demand = 800 kw; pf=80%; PFM = 1.086; demand charge = $10/kVA pf penalty = 800*$10*(0.086) = $688/month $0.45 per kva of reactive demand in excess of 50% of the kw demand; Demand = 800 kw; pf=80%; kvar demand = 600; excess kvar demand= *0.50 =200kvar pf penalty = 200 kvar*($0.45/kvar) = $90/month kvarh charge $X per kvarh $ per kvarh kvarh = 500,000 pf penalty = 500,000* = $417/month kwh adjustment (note that this often applies where the kw demand is first adjusted) $P/kWh for first Q*kWh*demand $R/kWh for next S*kWh* demand $X/kWh for next Y*kWh demand $Z/kWh for all additional $0.040/kWh for first 100 kwh*demand $0.035/kWh for next 150kWh*demand $0.025/kWh for next 150kWh*demand $0.020/kWh for all additional kwh Actual demand = 800 kw; Adjusted demand = 1000 kw; kwh measured = 500,000 With penalty 100*1000=100, /kWh=$ *1000=150, /kWh=$ *1000=150, /kWh=$3750 (500, , , ,000)*$0.02/kWh = $2000 Total = $15,000 Without penalty 100*800=80, /kWh=$ *800=120, /kWh=$ *800=120, /kWh=$3000 (500,000-80, , ,000)*$0.02/kWh = $3600 Total = $14,000 Penalty = $15,000 - $14,000 = $1,000/month (in addition to demand penalty) 9
10 Table 2. Summary of Claimed Savings vs. Realistic Savings Description Primary PQ Benefit Stated EM Savings and Other Benefits Realistic EM Savings Reason for Discrepancy Products to address negative sequence currents Products to address unbalanced voltages (including zig-zag reactors) Surge protection PF Correction Harmonic Filters (passive, active) Black Box Solutions Residential Black Box Solutions Harmonic Mitigating Transformers (HMT) Neutral Blocking Filter Soft Starter Conservation Voltage Reduction (CVR) Negative Sequence Current reduction Negative Sequence Current reduction Elimination of voltage transients Reduce kvar flows on power system Control harmonic currents on power system. Reduce kvar flows on power system Balance voltage, PF correction, harmonic reduction, surge protection, voltage regulation Eliminate wasted energy in the form of heat in your home Do not allow third harmonic to circulate and/or pass through transformer windings. In combinations, cancel 5th, 7th, 11th, etc. Eliminate third harmonic from transformer secondary and downstream to load Minimizes voltage drop during motor starting Regulate voltage at 5-10% lower than nominal to reduce load on power system Eliminates reverse rotation action on motors yielding higher efficiency kw and kwh savings (usually > 10%) Reduces heating Prevents premature damage Eliminates reverse rotation action on motors yielding higher efficiency kw and kwh savings (usually > 10%) Reduces heating Prevents premature damage kw and kwh savings (usually > 20%) Prevents damage Reduces need for maintenance Improves performance of equipment kw and kwh savings (usually > 20%) Prevents damage Reduces need for maintenance Improves performance of equipment kw and kwh savings (usually > 20%) Reduce heating in equipment Reduces need for maintenance Improves performance of equipment Up to 30% kw and kwh Combinations of all other solutions including surge protection, harmonic reduction, phase balancing, etc.) Up to 35% of your bill Up to 20% savings kw and kwh by reducing harmonic currents 30% reduction in losses Very low core losses Very low winding losses Reduces I 2 R losses resulting from third harmonic from source to load up to 10% of energy from system Reduce current flow (increase capacity) Eliminate peak demand (kw) demand during motor starting (up to 6X motor full load power) Up to 30% energy and demand savings Improved operation of equipment kw and kwh savings (usually < 2 %) kw and kwh savings (usually < 2 %) May actually increase kw usage in some cases % 0.5-2% typical (excluding harmonics) If electric utility charges PF penalty, PF charges may actually save 10-30% or so (not kw or kwh savings) 0.5-8% based on location highest savings for filtering close to loads (plus PF savings) Less than 3% in most applications with typical combination loads Little or no savings because unit is a capacitor with MOV s installed at service entrance (only saving losses upstream). Typically <1% kw and kwh savings are often significantly overstated Typical savings < 4% Loss savings is correct but may be misleading 0.5-8% based on load mix (i.e. content of harmonic versus linear) Typically 1-3% Very close to zero (not perceivable in the big picture) because demand is 15 to 30 min average motor starting is less than 10 seconds. Motor starting is mostly reactive current anyway Individual load basis, some loads exhibit up to 20% savings but on a normal power system, net benefit is typically less than 2%. May reduce instantaneous power but more power is required to complete work (heat, etc.) May reduce light intensity below required value. Hard to measure and disprove stated claims. Easier to stretch the truth based on some savings. Hard to measure and disprove stated claims. Easier to stretch the truth based on some savings Uneducated consumers Easy to show large kva changes based on reducing kvar salesmen may purposely interchange kva and kw to cause confusion. NOTE: PF penalty is not the same as kw or kwh savings even though a multiplier is often used on kw yielding a penalty Confusion created between eliminating harmonic currents and reactive (kvar) power from load versus saving real kw or kwh harmonics are reactive current/power. Hard to focus, measure and prove or disprove. Often not allowed to see what is in the box (usually capacitors with MOV s) Uneducated consumers Hard to disprove looking at monthby-month data some months consumers will believe they saved energy but fail to consider variables like heating/cooling days, etc. Confusion created by the numbers or use of kva and kw savings Show very low loss (expensive) transformers in model and apply more typical TP-1 transformers Need a bypass switch to prove with similar/same load. Lack of education of consumers and sometimes salesmen Typically proven on one load and assumptions made on multiple loads Hard to measure and prove or disprove. Green Plugs Magic 10-20% None Uneducated consumers 10
11 Industry Application IA E Notes: 11
12 Eaton Corporation Electrical Group 1000 Cherrington Parkway Moon Township, PA United States 877-ETN-CARE ( ) Eaton.com 2010 Eaton Corporation All Rights Reserved Printed in USA Publication No. IA E / TBG March 2010 PowerChain Management is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.
ECONOMIC AND ELECTRICAL BENEFITS OF HARMONIC REDUCTION METHODS IN COMMERCIAL FACILITIES
ECONOMIC AND ELECTRICAL BENEFITS OF HARMONIC REDUCTION METHODS IN COMMERCIAL FACILITIES Jonathan K. Piel Engineering Manager Harmonics Limited [email protected] Daniel J. Carnovale, P.E. Power
Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE
Understanding Power Factor and How it Affects Your Electric Bill Presented by Scott Peele PE Understanding Power Factor Definitions kva, kvar, kw, Apparent Power vs. True Power Calculations Measurements
Power System Harmonics
Pacific Gas and Electric Company Power System Harmonics What are power system harmonics? Ideally, voltage and current waveforms are perfect sinusoids. However, because of the increased popularity of electronic
Energy Saving systems for Induction motors.
Energy Saving systems for Induction motors. Are they a sham? Do they work? There seems to be a resurgence in interest in the Nola energy saving algorithm for induction motors, with a number of manufacturers
A Low Cost Power Quality and Energy Savings Laboratory for Undergraduate Education and Research
Session #3133 A Low Cost Power Quality and Energy Savings Laboratory for Undergraduate Education and Research Abdullatif Bagegni, Vance Poteat Merrimack College Abstract This paper describes the design
Harmonics in your electrical system
Harmonics in your electrical system What they are, how they can be harmful, and what to do about them Abstract Harmonic currents, generated by non-linear electronic loads, increase power system heat losses
415V DISTRIBUTION FOR GREEN DATA CENTERS
White Paper: HMRP-WP001-A1 October 1, 2010 415V DISTRIBUTION FOR GREEN DATA CENTERS Prepared by: Anthony (Tony) Hoevenaars, P. Eng President and CEO Mirus International Inc. Copyright 2005 Mirus International
HOW HARMONICS HAVE CONTRIBUTED TO MANY POWER FACTOR MISCONCEPTIONS
White Paper: MIRUS-TP003-A January 15, 2014 HOW HARMONICS HAVE CONTRIBUTED TO MANY POWER FACTOR MISCONCEPTIONS Prepared by: Anthony (Tony) Hoevenaars, P. Eng President and CEO Mirus International Inc.
415V DISTRIBUTION FOR GREEN DATA CENTERS
White Paper: HMRP-WP001-A5 June 5, 2012 415V DISTRIBUTION FOR GREEN DATA CENTERS Prepared by: Anthony (Tony) Hoevenaars, P. Eng President and CEO Mirus International Inc. Copyright 2012 Mirus International
Power Factor The Basics
Power Factor The Basics OK. I ve heard a lot about this power factor stuff. What exactly is it? We hope to give you an easy explanation of what power factor is, and to answer the following most asked questions:
Product Data Bulletin
Product Data Bulletin Power System Harmonics Causes and Effects of Variable Frequency Drives Relative to the IEEE 519-1992 Standard Raleigh, NC, U.S.A. INTRODUCTION This document describes power system
Power factor correction. An introduction to technology and techniques
Power factor correction An introduction to technology and techniques 2 Contents Understanding power factor 03 Power factor correction 05 Implementing power factor correction techniques 06 Glossary 07 Further
APPLICATION OF IEEE STD 519-1992 HARMONIC LIMITS
APPLCATON OF EEE STD 19-199 HARMONC LMTS Thomas M. Blooming, P.E. [email protected] Eaton Electrical Asheville, North Carolina Daniel J. Carnovale, P.E. [email protected] Eaton Electrical Pittsburgh,
Three phase circuits
Three phase circuits THREE PHASE CIRCUITS THREE-PHASE ADVANTAGES 1. The horsepower rating of three-phase motors and the kva rating of three-phase transformers are 150% greater than single-phase motors
7. Reactive energy compensation
593 7. Reactive energy compensation 594 7. REACTIVE ENERGY COMPENSATION Reactive energy compensation is an important element for reducing the electricity bill and improving the quality of the electrical
Neutral Currents in Three Phase Wye Systems
POWER SYSTEMS ENGINEERING DATA PUBLISHED BY SQUARE D, OSHKOSH, WISCONSIN Subject: Neutral Currents in Three Phase Wye Systems by Robert Arthur Square D Company Oshkosh, Wisconsin (414) 46-80 and R. A.
Calculating Total Power Requirements for Data Centers
Calculating Total Power Requirements for Data Centers By Richard Sawyer White Paper #3 Executive Summary Part of data center planning and design is to align the power and cooling requirements of the IT
Power Quality Standards for Electric Service
Power Quality Standards for Electric Service Effective June 1, 2008 A transition period will exist from June 1 through December 31, 2008 in which installations may be approved and connected as long as
The Different Types of UPS Systems
The Different Types of UPS Systems By Neil Rasmussen White Paper #1 Revision 5 Executive Summary There is much confusion in the marketplace about the different types of UPS systems and their characteristics.
APPLICATION OF IEEE STD 519-1992 HARMONIC LIMITS
APPLCATON OF EEE STD 519-199 HARMONC LMTS Thomas M. Blooming, P.E. [email protected] Eaton Electrical Asheville, North Carolina Daniel J. Carnovale, P.E. [email protected] Eaton Electrical Pittsburgh,
VOLTAGE REGULATOR AND PARALLEL OPERATION
VOLTAGE REGULATOR AND PARALLEL OPERATION Generator sets are operated in parallel to improve fuel economy and reliability of the power supply. Economy is improved with multiple paralleled generators by
DESIGNING MODERN ELECTRICAL SYSTEMS WITH TRANSFORMERS THAT INHERENTLY REDUCE HARMONIC DISTORTION IN A PC-RICH ENVIRONMENT
DESIGNING MODERN ELECTRICAL SYSTEMS WITH TRANSFORMERS THAT INHERENTLY REDUCE HARMONIC DISTORTION IN A PC-RICH ENVIRONMENT by Philip J. A. Ling, P.Eng. Cyril J. Eldridge, B. Sc. POWERSMITHS INTERNATIONAL
3-PHASE LOW VOLTAGE NETWORK LOAD BALANCER : A COST EFFECTIVE SOLUTION TO LINE VOLTAGE VARIATIONS
3-PHASE LOW VOLTAGE NETWORK LOAD BALANCER : A COST EFFECTIVE SOLUTION TO LINE VOLTAGE VARIATIONS Pierre FRISTOT Olivier CONSTANT Catherine MONCET Omegawatt - France Omegawatt - France SDET - France [email protected]
APPLICATION NOTE. Increasing PV Hosting Capacity on LV Secondary Circuits with the Gridco System empower TM Solution
APPLICATION NOTE Increasing PV Hosting Capacity on LV Secondary Circuits with the Gridco System empower TM Solution INCREASING PV HOSTING WITH EMPOWER TM SOLUTION Executive Summary Distributed solar photovoltaic
At Load Power Factor Correction Phase 2: Refrigerated Vending Machines
At Load Power Factor Correction Phase 2: Refrigerated Vending Machines A Pilot Project to determine the feasibility and economics of small scale At Load Power Factor Correction Richard Ellenbogen, MEE
Fundamentals of Power
Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At
Chapter 24. Three-Phase Voltage Generation
Chapter 24 Three-Phase Systems Three-Phase Voltage Generation Three-phase generators Three sets of windings and produce three ac voltages Windings are placed 120 apart Voltages are three identical sinusoidal
Mitigating data center harmonics
Mitigating data center harmonics Patricia Matwijec Product Manager Eaton Ed Spears Product Marketing Manager Eaton Executive summary Line harmonics can have costly and disruptive effects on electrical
Understanding Power Factor, Crest Factor, and Surge Factor. White Paper #17
Understanding Power Factor, Crest Factor, and Surge Factor White Paper #17 Executive Summary This paper explains the technical terms of Power Factor, Crest Factor, and Surge Factor. The use of these terms
Voltage Unbalance and Motors
Voltage Unbalance and Motors Background Voltage unbalance occurs when the RMS line voltages on a poly-phase system are unequal. Voltages are seldom perfectly balanced between phases, but when this unbalance
Low Voltage Products
Low Voltage Products ABB Power Quality Filters: The most efficient solution for active filtering of harmonics, smooth reactive power compensation and load balancing. Enabling trouble-free and efficient
The Importance of the X/R Ratio in Low-Voltage Short Circuit Studies
The Importance of the X/R Ratio in Low-Voltage Short Circuit Studies DATE: November 17, 1999 REVISION: AUTHOR: John Merrell Introduction In some short circuit studies, the X/R ratio is ignored when comparing
100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center. 598 N. Buth Rd 3215 Arrowhead Rd
100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center Introduction Roger Hedding Steven Schoenherr, P.E. ABB Inc. Minnesota Power 598 N. Buth Rd 3215 Arrowhead Rd Dousman,
Triplen Harmonics Mitigation 3 Phase Four-Wire Electrical Distribution System Using Wye- Zig-Zag Transformers
Journal Journal of of Emerging Emerging Trends Trends in in Engineering Engineering and and Applied Applied Sciences Sciences (JETEAS) (JETEAS) 1 1 (1): (1): 72-78 72-78 Scholarlink Research Institute
The Quest for Energy Efficiency. A White Paper from the experts in Business-Critical Continuity
The Quest for Energy Efficiency A White Paper from the experts in Business-Critical Continuity Abstract One of the most widely discussed issues throughout the world today is the rapidly increasing price
ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only
ATTACHMENT F CATEGORY 2 GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 20 KW BUT LESS THAN OR EQUAL TO 150 KW Also Serves as Application for Category
Power Factor Correction for Power Systems First Semester Report Spring Semester 2007
Power Factor Correction for Power Systems First Semester Report Spring Semester 2007 by Pamela Ackerman Prepared to partially fulfill the requirements for EE401 Department of Electrical and Computer Engineering
Introduction. Harmonics and IEEE 519 Page 1 of 19
Introduction In an ideal power system, the voltage supplied to customer equipment, and the resulting load current are perfect sine waves. In practice, however, conditions are never ideal, so these waveforms
EXTENDING THE LIFE OF POWER FACTOR CAPACITORS
by John Houdek, President, Allied Industrial Marketing, Inc., and Cesar Chavez, Engineering Manager, ARTECHE / Inelap Abstract: The addition of power factor improvement capacitors to individual motors
Motor Protection Voltage Unbalance and Single-Phasing
Motor Protection Voltage Unbalance and Single-Phasing Cooper Bussmann contributes the following information, which is an excerpt from their 190-page handbook SPD Selecting Protective Devices Based on the
MAKING THE BUSINESS CASE FOR ENERGY EFFICIENCY. Shirley J. Hansen, Ph.D.
MAKING THE BUSINESS CASE FOR ENERGY EFFICIENCY Shirley J. Hansen, Ph.D. Soaring energy prices and growing concerns about global warming have highlighted our critical energy efficiency needs. Everyone at
ENGINEERING REPORT. XYZ Corporation 100 Anyplace Drive Chicago, Illinois 60613
ENGINEERING REPORT XYZ Corporation 100 Anyplace Drive Chicago, Illinois 60613 PERFORMED BY: MIDWEST ELECTRICAL CONSULTANTS, INC 18055 UPLAND DRIVE TINLEY PARK, ILLINOIS 60487 (708) 444-0001 fax: 444-0003
Standards of Power Quality with reference to the Code of Practice for Energy Efficiency of Electrical Installations
Standards of Power Quality with reference to the Code of Practice for Energy Efficiency of Electrical Installations Ir. Martin WU Kwok-tin, Energy Efficiency Office, Electrical & Mechanical Services Department
POWERING IN-FLIGHT ENTERTAINMENT EQUIPMENT FOR COMMERCIAL AIRCRAFT
POWERING IN-FLIGHT ENTERTAINMENT EQUIPMENT FOR COMMERCIAL AIRCRAFT WHITE PAPER: TW0061 December 2008 R. DeLuca L. Rozenblat 1 About the Authors Ron DeLuca Ron DeLuca is Vice President - Engineering of
Line Reactors and AC Drives
Line Reactors and AC Drives Rockwell Automation Mequon Wisconsin Quite often, line and load reactors are installed on AC drives without a solid understanding of why or what the positive and negative consequences
Considering the effects of UPS operation with leading power factor loads
Considering the effects of UPS operation with leading power factor loads Over the past five years, a new generation of data processing and communications equipment has become prevalent in modern data centers
Effective: September 10, 2006 Vermont Attachment 1 to Rule 5.500 Public Service Board Page 1 of 6
Public Service Board Page 1 of 6 STANDARD APPLICATION FOR INTERCONNECTION OF GENERATION RESOURCES IN PARALLEL TO THE ELECTRIC SYSTEM OF: (Interconnecting Utility) Preamble and Instructions: An owner of
The Different Types of UPS Systems
White Paper 1 Revision 7 by Neil Rasmussen > Executive summary There is much confusion in the marketplace about the different types of UPS systems and their characteristics. Each of these UPS types is
Power Quality for Information Technology System
Power Quality for Information Technology System ITS OBVIOUS THE TOLERANCE IS DIFFRENT But What isn t Tobvious? HOW MANY OF YOU HAVE : A COMPUTER AT HOME? = Computers are not screens and Keyboards COMPUTERS
Electrical Systems. <Presenter>
Review Root Causes of Energy Inefficiency Roadmap to Maximize Energy Efficiency Best Practices Alternative Energy Sources Controls Take Aways Seek Professional Help. ENERGY INEFFICIENCY OF
TECHNICAL GUIDE A GUIDE FOR THE SELECTION OF ENERGY EFFICIENT TECHNOLOGIES
TECHNICAL GUIDE A GUIDE FOR THE SELECTION OF ENERGY EFFICIENT TECHNOLOGIES Table of Contents 1. Introduction 1 2. Estimating Energy Savings and Costs 1 Direct Energy Savings 1 Indirect Energy Savings 2
3-Phase AC Calculations Revisited
AN110 Dataforth Corporation Page 1 of 6 DID YOU KNOW? Nikola Tesla (1856-1943) came to the United States in 1884 from Yugosiavia. He arrived during the battle of the currents between Thomas Edison, who
POWER SYSTEM HARMONICS. A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS
A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS By: Robert G. Ellis, P. Eng., Rockwell Automation Medium Voltage Business CONTENTS INTRODUCTION...
Improvement of Power Factor for Industrial Plant with Automatic Capacitor Bank
Improvement of Power Factor for Industrial Plant with Automatic Capacitor Bank Marlar Thein Oo, Ei Ei Cho Abstract-This paper is intended to uplift the technological standard of industrial plants. The
The Different Types of UPS Systems
Systems White Paper 1 Revision 6 by Neil Rasmussen Contents Click on a section to jump to it > Executive summary There is much confusion in the marketplace about the different types of UPS systems and
GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta
GENERATOR SELECTION Generators must be sized to handle their load based on the continuous KW, kilowatt load, and KVA, kilovoltamp load, and the worst case starting load KW + KVA. They must be derated for
Reactive Power and Importance to Bulk Power System OAK RIDGE NATIONAL LABORATORY ENGINEERING SCIENCE & TECHNOLOGY DIVISION
Reactive Power and Importance to Bulk Power System OAK RIDGE NATIONAL LABORATORY ENGINEERING SCIENCE & TECHNOLOGY DIVISION Outline What is Reactive Power and where does it come from? Why is it important?
Line to Ground Voltage Monitoring on Ungrounded and Impedance Grounded Power Systems
Line to Ground Voltage Monitoring on Ungrounded and Impedance Grounded Power Systems by Reza Tajali, P.E. Square D Company, Power Systems Engineering Group 295 Tech Park Drive LaVergne, Tennessee 37086
Developing a Utility/Customer Partnership To Improve Power Quality and Performance
Developing a Utility/Customer Partnership To Improve Power Quality and Performance Mark McGranaghan Electrotek Concepts Knoxville, TN Abstract Many industrial and commercial electric customers now require
Starting Current Reduction of Residential HVAC System and Peak-Load Impact of Power System: A Case Study
Starting Current Reduction of Residential HVAC System and Peak-Load Impact of Power System: A Case Study By Paul I-Hai Lin Professor of Electrical and Computer Engineering Technology P.E. (State of Indiana
Impact of Leading Power Factor on Data Center Generator Systems
Impact of Leading Power Factor on Data Center Generator Systems White Paper 200 Revision 0 by Neil Rasmussen Executive summary IT devices may exhibit electrical input current with a characteristic called
Rotary Phase Converters
FACTS from Ronk Electrical Industries, Inc. Bulletin 11981 Rotary Phase Converters ROTOVERTER Pat. No. 3,670,238 ROTO-CON Pat. No. 4,158,225 What are the ROTO-CON and ROTOVERTER power converters? The ROTO-CON
Basic Electrical Technology Dr. L. Umanand Department of Electrical Engineering Indian Institute of Science, Bangalore. Lecture - 33 3 phase System 4
Basic Electrical Technology Dr. L. Umanand Department of Electrical Engineering Indian Institute of Science, Bangalore Lecture - 33 3 phase System 4 Hello everybody. So, in the last class we have been
POWER FACTOR CORRECTION
[CATALOGUE PFC-SFC] POWER FACTOR CORRECTION INDUSTRIAL SWITCHGEAR & AUTOMATION SPECIALISTS A component of nhp s green star solution... www.nhp.com.au Power Factor - What does it mean? Where open electricity
factor max Delivering Electrical Efficiency INFORMATION PACK factor max
INFORMATION PACK Delivering Electrical Efficiency Where innovation leads the way is a Canadian company that distributes efficient energy saving devices for commercial and industrial customers. The solutions
Business Energy Efficiency. Webinar August 29, 2012
Business Energy Efficiency Webinar August 29, 2012 Today s presenters and some notes... John Pirko LeClairRyan Greg Booth PowerServices, Inc. Roy Palk LeClairRyan Welcome. With the high number of attendees,
Paralleling Power Sources Which Share a Common Neutral
Paralleling Power Sources Which Share a Common Neutral By: Tony Hoevenaars, P.E., President & CEO, Mirus International, Inc. Mike McGraw, President, NSOEM, Inc. When paralleling power sources that share
Energy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
Electricity Terminology. Simplifying energy management
Simplifying energy management AMR Automated Meter Reading - automatic collection of data from meters which is transferred to a central database for billing and/or analysis. Balancing Mechanism The mechanism
PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP
PacifiCorp Original Sheet No. 476 APPENDIX 2 TO SGIP SMALL GENERATOR INTERCONNECTION REQUEST (Application Form) Transmission Provider: Designated Contact Person: Address: Telephone Number: An Interconnection
Application Guide. Power Factor Correction (PFC) Basics
Power Factor Correction (PFC) Basics Introduction Power Factor, in simple terms, is a number between zero and one that represents the ratio of the real power to apparent power. Real power (P), measured
Inverter technology. bulletin
Inverter technology application bulletin What is the inverter component? The inverter is an electronic power component that continuously varies the electricity supply frequency of an electric motor. The
21 st Century Facilities
Electrical Testing 21 st Century Facilities Facility Owners face tough challenges 24 X 7 reliability needed Non linear loads cause harmonics VFD Computers Switching transients disrupt operations Less customer
By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document
By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By the Authority Vested By Part 5 of the United States Code 552(a) and Part 1 of the Code of Regulations 51 the attached document has
Energy Cost Reduction through Load Balancing & Load Shedding
white paper Energy Cost Reduction through Load Balancing & Load Shedding SCR controllers firing in phase angle degrade the power factor while increasing harmonics and electrical noise. A poor power factor
UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES
UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES WHITE PAPER: TW0062 36 Newburgh Road Hackettstown, NJ 07840 Feb 2009 Alan Gobbi About the Author Alan Gobbi Alan Gobbi
Power Quality Issues, Impacts, and Mitigation for Industrial Customers
Power Quality Issues, Impacts, and Mitigation for Industrial Customers By Kevin Olikara, Power and Energy Management Products Rockwell Automation, Inc. Now, more than ever, electronic equipment and computing
HARMONIC DISTORTION IN THE ELECTRIC SUPPLY SYSTEM
Technical Note No.3 March 2000 HARMONIC DISTORTION IN THE ELECTRIC SUPPLY SYSTEM This Technical Note discusses harmonic distortion, its causes and adverse effects, what levels are unacceptable and how
Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.
By Darrell G. Broussard, P.E. Introduction: As engineers, we are aware that electrical power systems have grown. How much have they grown? When was the last time you specified a 2400-volt system, a 4160-volt
AMI and DA Convergence: Enabling Energy Savings through Voltage Conservation
AMI and DA Convergence: Enabling Energy Savings through Voltage Conservation September 2010 Prepared for: By Sierra Energy Group The Research & Analysis Division of Energy Central Table of Contents Executive
PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions
PMCS Integrated Energy Management Solution Unlock the Full Potential of Power Networks Through Integration Power Management Control System (PMCS) is a highly customizable, fully integrated end-to-end Energy
Titelgrau belassen! Leere Vorlage
Titelgrau belassen! Leere Vorlage MAVOWATT 20 Energy Platform Energy and Power Analyzer MAVOWATT 20 The new Energy and Power Analyzer 2 Klaus-Peter Richter Product Management 10.3.2010 Page 2 Applications
Alternative data center power
Alternative data center power A quantitative TCO comparison of 400V AC and 600V AC power systems Abstract Power efficiency has become a critical focus for IT and facilities managers as they struggle to
PM734F - Technical Data Sheet Winding 28
- Technical Data Sheet Winding 28 SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international standards, including
Eaton s E-Series protective relay family
E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family
HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet
HCM434F - Winding 311 Technical Data Sheet HCM434F SPECIFICATIONS & OPTIONS STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards
Power Quality. Uninterruptible Power Supply
Quality Uninterruptible Supply In the electrical system environment, power disturbances will occur. These can be caused by faults on the distribution system, the operation of nearby equipment, lightning
PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS
PI144K - Winding 311 Technical Data Sheet PI144K SPECIFICATIONS & OPTIONS STANDARDS TERMINALS & TERMINAL BOX Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section
My Seven Step Formula For Marketing & Sales Success By: Michael D. Black, M.S.
I work with entrepreneurs and sales professionals to cut all the fat & waste out of your marketing and make your sales efforts 500% more effective Guaranteed! Smartphone Users: Scan QR with RedLaser or
7-41 POWER FACTOR CORRECTION
POWER FTOR CORRECTION INTRODUCTION Modern electronic equipment can create noise that will cause problems with other equipment on the same supply system. To reduce system disturbances it is therefore essential
Digital Energy ITI. Instrument Transformer Basic Technical Information and Application
g Digital Energy ITI Instrument Transformer Basic Technical Information and Application Table of Contents DEFINITIONS AND FUNCTIONS CONSTRUCTION FEATURES MAGNETIC CIRCUITS RATING AND RATIO CURRENT TRANSFORMER
However, industrial applications may utilize a relay, which short-circuits the ICL path after the inrush sequence.
Application note for Inrush Current Limiters (ICL) Turning on electrical devices generally cause high inrush currents which can damage electronic components and cause interruption of the line voltage if
HARMONICS AND HOW THEY RELATE TO POWER FACTOR. W. Mack Grady The University of Texas at Austin Austin, Texas 78712
Abstract HARMONICS AND HOW THEY RELATE TO POWER FACTOR W. Mack Grady The University of Texas at Austin Austin, Texas 787 Robert J. Gilleskie San Diego Gas & Electric San Diego, California 93 We are all
Commercial Energy Savings Guide. www.touchstoneenergy.coop
Commercial Energy Savings Guide www.touchstoneenergy.coop NRECA Pocket Savings Guide Pag.indd 1-3 2/7/05 4:19:07 PM Commercial Energy Saving Tips Notes: This guide provides basic hints on ways to reduce
Energy Efficiency and Automated Demand Response Program Integration: Time for a Paradigm Shift
Energy Efficiency and Automated Demand Response Program Integration: Time for a Paradigm Shift Christine Riker and Kitty Wang, Energy Solutions Fred Yoo, Pacific Gas and Electric Company ABSTRACT The practice
How To Understand And Understand The Theory Of Electricity
DIRECT CURRENT AND ALTERNATING CURRENT SYSTEMS N. Rajkumar, Research Fellow, Energy Systems Group, City University Northampton Square, London EC1V 0HB, UK Keywords: Electrical energy, direct current, alternating
Equipment: Power Supply, DAI, Variable resistance (8311), Variable inductance (8321)
Lab 4: 3-phase circuits. Objective: to study voltage-current relationships in 3-phase circuits; to learn to make delta and Y connections; to calculate and measure real, apparent, and reactive powers. Equipment:
Metering for today s systems
Metering for today s systems The sub-meter gathers data on the building side of the utility company meter. This allows us to break out usage so data can be collected from individual circuits, a single
OPTIMIZING CONDENSER WATER FLOW RATES. W. A. Liegois, P.E. Stanley Consultants, Inc. Muscatine, Iowa
OPTIMIZING CONDENSER WATER FLOW RATES W. A. Liegois, P.E. Stanley Consultants, Inc. Muscatine, Iowa T.A. Brown, P.E. Thermal Energy Corporation Houston, Texas ABSTRACT Most chillers are designed for a
