Cisco Nexus 7000 Hardware Architecture
|
|
|
- Mitchell Sherman
- 10 years ago
- Views:
Transcription
1
2 Cisco Nexus 7000 Hardware Architecture
3 Session Goal To provide you with a thorough understanding of the Cisco Nexus 7000 switching architecture, supervisor, fabric, and I/O module design, packet flows, and key forwarding engine functions This session will not examine NX-OS software architecture or other Nexus platform architectures Related sessions: BRKDCT-2204 Nexus 7000/5000/2000/1000v Deployment Case Studies BRKIPM-3062 Nexus Multicast Design Best Practices BRKDCT-2121 VDC Design and Implementation BRKDCT-2048 Deploying Virtual Port Channel in NX-OS BRKARC-3472 NX-OS Routing & Layer 3 Switching BRKDCT-2081 Cisco FabricPath Technology and Design TECDCT-3297 Operating and Deploying NX-OS BRKCRS-3144 Troubleshooting Cisco Nexus 7000 Series Switches LTRCRT-5205 Configuring Nexus 7000 Virtualization Lab LTRDCT-1142 FabricPath Deployment in the Data Center Lab 3 3
4 What Is Nexus 7000? Data-center class Ethernet switch designed to deliver high-availability, system scale, usability, investment protection I/O Modules Supervisor Chassis Fabrics 4
5 Agenda Chassis Architecture Supervisor and I/O Module Architecture Forwarding Architecture Fabric Architecture I/O Module Queuing Layer 2 Forwarding IP Forwarding IP Multicast Forwarding Classification NetFlow Conclusion 5
6 Nexus 7000 Chassis Family NX-OS 4.1(2) and later Nexus 7010 Nexus RU 25RU Front N7K-C7010 Rear Front N7K-C7018 Rear Nexus 7009 NX-OS 5.2(1) and later 14RU Front N7K-C7009 Rear 6
7 Key Chassis Components Common components: Supervisor s I/O Modules Power Supplies Chassis-specific components: Fabric Modules Fan Trays 7
8 Agenda Chassis Architecture Supervisor and I/O Module Architecture Forwarding Architecture Fabric Architecture I/O Module Queuing Layer 2 Forwarding IP Forwarding IP Multicast Forwarding Classification NetFlow Conclusion 8
9 Supervisor 1 Performs control plane and management functions Dual-core 1.66GHz x86 processor with 8GB DRAM 2MB NVRAM, 2GB internal bootdisk, compact flash slots, USB Console, aux, and out-of-band management interfaces Interfaces with I/O modules via 1G switched EOBC Houses dedicated central arbiter ASIC Controls access to fabric bandwidth via dedicated arbitration path to I/O modules N7K-SUP1 ID LED Status LEDs AUX Port Console Port Management Ethernet Compact Flash Slots Reset Button USB Ports CMP Ethernet 9
10 Nexus 7000 I/O Module Families M Series and F Series M family L2/L3/L4 with large forwarding tables and rich feature set N7K-M148GT-11/N7K-M148GT-11L N7K-M132XP-12/ N7K-M132XP-12L N7K-M108X2-12L N7K-M148GS-11/N7K-M148GS-11L F family High performance, low latency, low power with streamlined feature set N7K-F132XP-15 N7K-F248XP-25 10
11 Supported in NX-OS release 5.0(2a) and later 8-Port 10GE M1 I/O Module N7K-M108X2-12L 8-port 10G with X2 transceivers 80G full-duplex fabric connectivity Two integrated forwarding engines (120Mpps) Support for XL forwarding tables (licensed feature) Distributed L3 multicast replication 802.1AE LinkSec N7K-M108X2-12L 12
12 8-Port 10G XL M1 I/O Module Architecture N7K-M108X2-12L EOBC To Central Arbiter To Fabric Modules Fabric 1 LC CPU VOQs Forwarding Forwarding VOQs Replication Replication Replication Replication 10G MAC 10G MAC 10G MAC 10G MAC 10G MAC 10G MAC 10G MAC 10G MAC Linksec Linksec Linksec Linksec Linksec Linksec Linksec Linksec Front Panel Ports 13
13 N7K-M132XP-12 Supported in all releases N7K-M132XP-12L Supported in NX-OS release 5.1(1) and later 32-Port 10GE M1 I/O Modules N7K-M132XP-12, N7K-M132XP-12L 32-port 10G with SFP+ transceivers 80G full-duplex fabric connectivity Integrated 60Mpps forwarding engine XL forwarding engine on L version Oversubscription option for higher density (up to 4:1) Supports Nexus 2000 (FEX) connections Distributed L3 multicast replication LISP support 802.1AE LinkSec N7K-M132XP-12/ N7K-M132XP-12L 15
14 Shared vs. Dedicated Mode To Fabric rate-mode shared (default) One port group Another port group 10G Shared mode Four interfaces in port group share 10G bandwidth To Fabric rate-mode dedicated 10G Port group group of contiguous even or odd ports that share 10G of bandwidth (e.g., ports 1,3,5,7) Dedicated mode First interface in port group gets 10G bandwidth Other three interfaces in port group disabled 16
15 32-Port 10G M1 I/O Module Architecture N7K-M132XP-12, N7K-M132XP-12L EOBC To Central Arbiter To Fabric Modules Fabric 1 LC CPU VOQs Forwarding VOQs Replication Replication Replication Replication 10G MAC 10G MAC 10G MAC 10G MAC 10G MAC 10G MAC 10G MAC 10G MAC 4:1 Mux + Linksec 4:1 Mux + Linksec 4:1 Mux + Linksec 4:1 Mux + Linksec 4:1 Mux + Linksec 4:1 Mux + Linksec 4:1 Mux + Linksec 4:1 Mux + Linksec Front Panel Ports 17
16 32-Port 1G/10GE F1 I/O Module N7K-F132XP-15 Supported in NX-OS release 5.1(1) and later 32-port 1G/10G with SFP/SFP+ transceivers 230G full-duplex fabric connectivity (320G local switching) System-on-chip (SoC)* forwarding engine design 16 independent SoC ASICs Layer 2 forwarding with L3/L4 services (ACL/QoS) FabricPath-capable FCoE-capable N7K-F132XP-15 * sometimes called switch-on-chip 20
17 32-Port 1G/10G F1 I/O Module Architecture N7K-F132XP-15 EOBC To Fabric Modules To Central Arbiter LC CPU Arbitration Aggregator Fabric 1 Fabric 1 2 X 10G SoC 2 X 10G SoC 2 X 10G SoC 2 X 10G SoC 2 X 10G SoC 2 X 10G SoC 2 X 10G SoC 2 X 10G SoC 2 X 10G SoC 2 X 10G SoC 2 X 10G SoC 2 X 10G SoC 2 X 10G SoC 2 X 10G SoC 2 X 10G SoC 2 X 10G SoC Front Panel Ports 21
18 48-Port 1G/10GE F2 I/O Module N7K-F248XP-25 Supported in NX-OS release 6.0(1) and later 48-port 1G/10G with SFP/SFP+ transceivers 480G full-duplex fabric connectivity System-on-chip (SoC)* forwarding engine design 12 independent SoC ASICs Layer 2/Layer 3 forwarding with L3/L4 services (ACL/QoS) Supports Nexus 2000 (FEX) connections FabricPath-capable FCoE-ready N7K-F248XP-25 * sometimes called switch-on-chip 22
19 48-Port 1G/10G F2 I/O Module Architecture N7K-F248XP-25 EOBC To Fabric Modules To Central Arbiters LC CPU Arbitration Aggregator Fabric 2 4 X 10G SoC 4 X 10G SoC 4 X 10G SoC 4 X 10G SoC 4 X 10G SoC 4 X 10G SoC 4 X 10G SoC 4 X 10G SoC 4 X 10G SoC 4 X 10G SoC 4 X 10G SoC 4 X 10G SoC Front Panel Ports 23
20 F2-Only VDC Communication between F2- only VDC and M1/F1 VDC must be through external connection F2 modules do not interoperate with other Nexus 7000 modules Must deploy in an F2 only VDC Can be default VDC, or any other VDC Use the limit-resource module-type f2 VDC configuration command System with only F2 modules and empty configuration boots with F2-only default VDC automatically F2 module F2 module F2 module M1 module M1 module F1 module F1 module F2-only VDC M1/F1 VDC M1/F1 modules can exist in same chassis as F2 modules, but not in the same VDC 25
21 Agenda Chassis Architecture Supervisor and I/O Module Architecture Forwarding Architecture Fabric Architecture I/O Module Queuing Layer 2 Forwarding IP Forwarding IP Multicast Forwarding Classification NetFlow Conclusion 28
22 M1 Forwarding Hardware Hardware forwarding engine(s) integrated on every I/O module 60Mpps per forwarding engine Layer 2 bridging with hardware MAC learning 60Mpps per forwarding engine Layer 3 IPv4 and 30Mpps Layer 3 IPv6 unicast Layer 3 IPv4 and IPv6 multicast support (SM, SSM, bidir) MPLS OTV IGMP snooping RACL/VACL/PACL QoS remarking and policing policies Policy-based routing (PBR) Unicast RPF check and IP source guard Ingress and egress NetFlow (full and sampled) Hardware Table M1 Modules M1-XL Modules without License M1-XL Modules with License FIB TCAM 128K 128K 900K Classification TCAM (ACL/QoS) 64K 64K 128K MAC Address Table 128K 128K 128K NetFlow Table 512K 512K 512K 29
23 M1 Forwarding Architecture FE Daughter Card Ingress policing Ingress ACL and QoS classification Unicast RPF check Layer 3 Ingress Pipeline Egress policing Egress Pipeline Egress NetFlow collection Ingress NetFlow collection FIB TCAM and adjacency table lookups for Layer 3 forwarding ECMP hashing Multicast RPF check Egress ACL and QoS classification Ingress MAC table lookups IGMP snooping lookups IGMP snooping redirection Layer 2 Egress MAC lookups IGMP snooping lookups Packet Headers from I/O Module Replication Final lookup result to I/O Module Replication 30
24 F2 Forwarding Hardware Each SoC forwarding engine services 4 frontpanel 10G ports (12 SoCs per module) 60Mpps per SoC Layer 2 bridging with hardware MAC learning 60Mpps per forwarding engine Layer 3 IPv4/ IPv6 unicast Layer 3 IPv4 and IPv6 multicast support (SM, SSM) IGMP snooping RACL/VACL/PACL QoS remarking and policing policies Policy-based routing (PBR) Unicast RPF check and IP source guard FabricPath forwarding Ingress sampled NetFlow (future) FCoE (future) Hardware Table Per F2 SoC Per F2 Module MAC Address Table 16K 256K* FIB TCAM 32K IPv4/16K IPv6 32K IPv4/16K IPv6 Classification TCAM (ACL/QoS) 16K 192K* * Assumes specific configuration to scale SoC resources 31
25 F2 Forwarding Architecture To/From Central Arbiter To Fabric Virtual output queues From Fabric Ingress and egress forwarding decisions (L2/L3 lookups, ACL/QoS, etc.) Ingress Buffer (VOQ) Forwarding Egress Buffer 4 X 10G SoC Egress fabric receive buffer Skid buffer Accommodates pause reaction time Pre-Forwarding Ingress Buffer FIB, ADJ, MAC, ACL, QoS, MET Forwarding tables 1G and 10G capable interface MAC 1G/10G MAC 1G/10G MAC Four front-panel interfaces per ASIC Port A 1G/10G Port B 1G/10G Port C 1G/10G Port D 1G/10G 32
26 F1 Forwarding Hardware Each SoC forwarding engine services 2 frontpanel 10G ports (16 SoCs per module) 30Mpps per SoC Layer 2 bridging with hardware MAC learning IGMP snooping VACL/PACL QoS remarking policies FabricPath forwarding FCoE Hardware Table Per F1 SoC Per F1 Module MAC Address Table 16K 256K* Classification TCAM (ACL/QoS) 1K in/1k out 16K in/16k out* * Assumes specific configuration to scale SoC resources 33
27 Agenda Chassis Architecture Supervisor and I/O Module Architecture Forwarding Architecture Fabric Architecture I/O Module Queuing Layer 2 Forwarding IP Forwarding IP Multicast Forwarding Classification NetFlow Conclusion 35
28 Crossbar Switch Fabric Modules N7K-C7018-FAB-1/FAB-2 Two fabric generations available Fabric 1 and Fabric 2 Fabric Per-fabric module bandwidth Total bandwidth with 5 fabric modules Fabric 1 46Gbps per slot 230Gbps per slot Fabric 2 110Gbps per slot 550Gbps per slot Each installed fabric increases available per-payload slot bandwidth Different I/O modules leverage different amount of fabric bandwidth All I/O modules compatible with both Fabric 1 and Fabric 2 Access to fabric bandwidth controlled using QoS-aware central arbitration with VOQ N7K-C7009-FAB-2 N7K-C7010-FAB-1/FAB-2 36
29 Multistage Crossbar Nexus 7000 implements 3-stage crossbar switch fabric Stages 1 and 3 on I/O modules Stage 2 on fabric modules Fabric Modules 2nd stage x 23Gbps (Fab1) or 2 x 55Gbps (Fab2) per slot per fabric module Up to 230Gbps (Fab1) or 550Gbps (Fab2) per I/O module with 5 fabric modules installed 1st stage Ingress Module Egress Module 3rd stage 20 x 23Gbps (Fab1) or 20 x 55Gbps (Fab2) channels per fabric module 37
30 I/O Module Capacity Fabric 1 184Gbps 138Gbps 230Gbps 46Gbps 92Gbps per slot bandwidth Local Fabric 2 (480G) 46Gbps/slot Fabric 1 Modules Fabric 1 ASICs 1 One fabric Any port can pass traffic to any other port in system Two fabrics 80G M1 module has full bandwidth Local Fabric 1 (230G) 46Gbps/slot 46Gbps/slot Fabric 1 ASICs Fabric 1 ASICs 2 3 Five fabrics 230G F1 module has maximum bandwidth 480G F2 module limited to 230G per slot Local Fabric 1 (80G) 46Gbps/slot 46Gbps/slot Fabric 1 ASICs Fabric 1 ASICs
31 I/O Module Capacity Fabric 2 Fabric channels run at lowest common speed Fab2 does NOT make Fab1-based modules faster!! 440Gbps 220Gbps 330Gbps 550Gbps 110Gbps Local Fabric 2 (480G) Fabric 2 Modules 110Gbps/slot 1 Fabric 2 ASICs One fabric per slot bandwidth Fabric 2 ASICs 2 Any port can pass traffic to any other port in system Two fabrics 80G M1 module has full bandwidth Local Fabric 1 (230G) Fabric 2 ASICs 3 Five fabrics 230G F1 module has maximum bandwidth Local Fabric 1 (80G) Fabric 2 ASICs 4 480G F2 module has maximum bandwidth Fabric 2 ASICs 5 39
32 Fabric 1 to Fabric 2 Migration Online, non-disruptive migration of Fabric 1 to Fabric 2 supported Upgrade to software release supporting Fabric 2 Remove one Fabric 1 module at a time, replace with Fabric 2 module Allow new Fabric 2 module to come completely online before removing next Fabric 1 module Mix of Fabric 1/Fabric 2 not recommended or supported for longer than duration of the migration Within 12 hours of install of first Fabric 2 module, system syslogs warning to complete migration 40
33 Arbitration, VOQ, and Crossbar Fabric Arbitration, VOQ, and fabric combine to provide all necessary infrastructure for packet transport inside switch Central arbitration Controls scheduling of traffic into fabric based on fairness, priority, and bandwidth availability at egress ports Virtual Output Queues (VOQs) Provide buffering and queuing for ingress-buffered switch architecture Crossbar fabric Provides dedicated, high-bandwidth interconnects between ingress and egress I/O modules 41
34 Agenda Chassis Architecture Supervisor and I/O Module Architecture Forwarding Architecture Fabric Architecture I/O Module Queuing Layer 2 Forwarding IP Forwarding IP Multicast Forwarding Classification NetFlow Conclusion 45
35 Buffering, Queuing, and Scheduling Buffering storing packets in memory Needed to absorb bursts, manage congestion Queuing buffering packets according to traffic class Provides dedicated buffer for packets of different priority Scheduling controlling the order of transmission of buffered packets Ensures preferential treatment for packets of higher priority and fair treatment for packets of equal priority Nexus 7000 uses queuing policies and network-qos policies to define buffering, queuing, and scheduling behavior Default queuing and network-qos policies always in effect in absence of any user configuration 46
36 I/O Module Buffering Models Buffering model varies by I/O module family M1 modules: hybrid model combining ingress VOQ-buffered architecture with egress port-buffered architecture F1/F2 modules: pure ingress VOQ-buffered architecture All configuration through Modular QoS CLI (MQC) Queuing parameters applied using class-maps/policy-maps/service-policies 47
37 Hybrid Ingress/Egress Buffered Model M1 I/O Modules Ingress port buffer Manages congestion in ingress forwarding/replication engines only Ingress VOQ buffer Manages congestion toward egress destinations over fabric Egress VOQ buffer Receives frames from fabric; also buffers multidestination frames Egress port buffer Manages congestion at egress interface Ingress port buffer Ingress VOQ buffer Ingress Module Egress VOQ buffer Egress port buffer Ingress Module Crossbar Fabric Egress Module Ingress Module 48
38 Ingress Buffered Model F1/F2 I/O Modules Ingress skid buffer Absorbs packets in flight after external flow control asserted Ingress VOQ buffer Manages congestion toward egress destinations over fabric Egress VOQ buffer Receives frames from fabric; also buffers multidestination frames Ingress skid buffer Ingress VOQ buffer Ingress Module Egress VOQ buffer Ingress Module Crossbar Fabric Egress Module Ingress Module 50
39 Distributed Buffer Pool Ingress-buffered architecture implements large, distributed buffer pool to absorb congestion Absorbs congestion at every ingress port contributing to congestion, leveraging all per-port ingress buffer Excess traffic does not consume fabric bandwidth, only to be dropped at egress port 2:1 Ingress:Egress 8:1 Ingress:Egress Ingress VOQ buffer Available buffer for congestion management: 1 2 Available buffer for congestion management: 3 1 Fabric 4 5 Fabric 2 Egress 6 Egress Ingress 7 8 Ingress 52
40 Agenda Chassis Architecture Supervisor and I/O Module Architecture Forwarding Architecture Fabric Architecture I/O Module Queuing Layer 2 Forwarding IP Forwarding IP Multicast Forwarding Classification NetFlow Conclusion 54
41 Layer 2 Forwarding Layer 2 forwarding traffic steering based on destination MAC address Hardware MAC learning CPU not directly involved in learning Forwarding engine(s) on each module have copy of MAC table New learns communicated to other forwarding engines via hardware flood to fabric mechanism Software process ensures continuous MAC table sync Spanning tree (PVRST or MST), Virtual Port Channel (VPC), or FabricPath ensures loop-free Layer 2 topology 55
42 Hardware Layer 2 Forwarding Process In Classic Ethernet and FabricPath edge switches, MAC table lookup drives Layer 2 forwarding Source MAC and destination MAC lookups performed for each frame, based on {VLAN,MAC} pairs Source MAC lookup drives new learns and refreshes aging timers Destination MAC lookup dictates outgoing switchport (CE/FabricPath local) or destination Switch ID (FabricPath remote) In FabricPath core switches, Switch ID (routing) table lookup drives Layer 2 forwarding Destination SID lookup dictates outgoing FabricPath interface and next hop 56
43 HDR = Packet Headers DATA = Packet Data CTRL = Internal Signaling M1 L2 Packet Flow Credit grant for fabric access 9 Supervisor Central Arbiter Return credit to pool 12 Fabric Module 1 Fabric Module 2 Fabric Module 3 VOQ arbitration and queuing 8 Transmit to fabric 10 Layer 3 ACL/QoS/ NetFlow lookups 6 Layer 3 Receive from fabric Return buffer credit 11 Submit packet headers for lookup Ingress port QoS Receive packet from wire VOQs Replication 10G MAC Linksec e1/1 2 Layer 2 Forwarding LinkSec decryption Module 1 L2 SMAC/ DMAC lookups Return result Layer 2 Forwarding 13 Module 2 Egress port QoS Transmit packet on wire VOQs Replication 10G MAC Linksec e2/1 LinkSec encryption 14 57
44 F1/F2 L2 Packet Flow HDR = Packet Headers DATA = Packet Data CTRL = Internal Signaling 7 Credit grant for fabric access Supervisor Return credit to pool 10 Central Arbiter Fabric Module 1 Fabric Module 2 Fabric Module 3 Fabric Module 4 Fabric Module 5 8 Transmit to fabric 9 VOQ arbitration Submit packet headers for lookup 3 Receive from fabric Return buffer credit Return result 5 6 VOQ FE SoC Module 1 Ingress L2 SMAC/ DMAC lookups, ACL/QoS lookups 4 VOQ SoC Module 2 2 Ingress port QoS (VOQ) e1/1 Receive packet from wire 1 Transmit packet on wire 11 e2/1 58
45 Agenda Chassis Architecture Supervisor and I/O Module Architecture Forwarding Architecture Fabric Architecture I/O Module Queuing Layer 2 Forwarding IP Forwarding IP Multicast Forwarding Classification NetFlow Conclusion 59
46 IP Forwarding Nexus 7000 decouples control plane and data plane Forwarding tables built on control plane using routing protocols or static configuration OSPF, EIGRP, IS-IS, RIP, BGP for dynamic routing Tables downloaded to forwarding engine hardware for data plane forwarding FIB TCAM contains IP prefixes Adjacency table contains next-hop information 60
47 Hardware IP Forwarding Process FIB TCAM lookup based on destination prefix (longest-match) FIB hit returns adjacency, adjacency contains rewrite information (nexthop) Pipelined forwarding engine architecture also performs ACL, QoS, and NetFlow lookups, affecting final forwarding result 61
48 IPv4 FIB TCAM Lookup HIT! Generate Lookup Key xx xx xx xx xx xx xx xx FIB TCAM Generate TCAM lookup key (destination IP address) Compare lookup key Index, # next-hops Index, # next-hops Index, # next-hops Index, # next-hops Index, # next-hops Index, # next-hops Index, # next-hops Index, # next-hops Index, # next-hops Index, # next-hops Index, # next-hops Index, # next-hops Hit in FIB returns result in FIB DRAM Index, # next-hops FIB DRAM Ingress unicast IPv4 packet header Load-Sharing Hash # nexthops Adj Index Flow Data Adjacency index identifies ADJ block to use mod Offset Modulo function selects exact next hop entry to use Forwarding Next-hop 1 (IF, MAC) Next-hop 2 (IF, MAC) Next-hop 3 (IF, MAC) Next-hop 4 (IF, MAC) Next-hop 5 (IF, MAC) Next-hop 6 (IF, MAC) Next-hop 7 (IF, MAC) Adjacency Table Return lookup result Result
49 ECMP Load Sharing Up to 16 hardware load-sharing paths per prefix Use maximum-paths command in routing protocols to control number of load-sharing paths Load-sharing is per-ip flow Configure load-sharing hash options with global ip load-sharing command: Source and Destination IP addresses Source and Destination IP addresses plus L4 ports (default) Destination IP address and L4 port Additional randomized number added to hash prevents polarization Automatically generated or user configurable value A /16 B /16 via Rtr-A via Rtr-B 63
50 HDR = Packet Headers DATA = Packet Data CTRL = Internal Signaling M1 L3 Packet Flow Credit grant for fabric access 9 Supervisor Central Arbiter Return credit to pool 12 Fabric Module 1 Fabric Module 2 Fabric Module 3 VOQ arbitration and queuing 8 Transmit to fabric 10 Layer 3 6 L3 FIB/ADJ lookup Ingress and egress ACL/QoS/NetFlow lookups Layer 3 Receive from fabric Return buffer credit 11 Submit packet headers for lookup Receive packet from wire 4 Ingress port QoS 3 1 VOQs Replication 10G MAC Linksec e1/1 2 Layer 2 Forwarding LinkSec decryption Module 1 L2 ingress and egress SMAC/ DMAC lookups Return result Layer 2 Forwarding 13 Module 2 Transmit packet on wire Egress port QoS VOQs Replication 10G MAC Linksec e2/1 14 LinkSec encryption 64
51 F2 L3 Packet Flow HDR = Packet Headers DATA = Packet Data CTRL = Internal Signaling 7 Credit grant for fabric access Supervisor Return credit to pool 10 Central Arbiter Fabric Module 1 Fabric Module 2 Fabric Module 3 Fabric Module 4 Fabric Module 5 8 Transmit to fabric 9 Return result VOQ arbitration 5 6 VOQ FE SoC Submit packet headers for lookup 3 Module 1 L2 ingress and egress SMAC/ DMAC lookups L3 FIB/ADJ lookup Ingress and egress ACL/QoS lookups 4 VOQ SoC Receive from fabric Egress port QoS Return buffer credit Module 2 2 Ingress port QoS (VOQ) e1/1 Receive packet from wire 1 Transmit packet on wire 11 e2/1 65
52 Layer 3 Forwarding with F1 I/O Modules F1 modules do not natively provide Layer 3 switching Cannot inter-vlan route on their own However, one or more M1/M1-XL modules can provide proxy Layer 3 services M1 forwarding engines can proxy route for F1 modules Proxy L3 forwarding enabled by default in M1/F1 VDC Packets destined to router MAC forwarded to M1 modules for Layer 3 via internal Router Port-Channel Selection of which port on which M1 module based on EtherChannel hash function Traffic requiring L3 from F1 modules traverses the fabric, vectoring toward M1 ports enabled for proxy L3 M1 module receiving such packets programmed to perform full ingress/egress L3 lookups 66
53 Proxy L3 Forwarding Conceptual From F1 perspective, Router MAC reachable through giant port-channel All packets destined to Router MAC forwarded through fabric toward one member port in that channel vlan 10 All F1 modules Up to 128 links All M1 modules interface vlan 10 ip address /24! interface vlan 20 ip address / vlan 20 67
54 Proxy L3 Forwarding Actual Can be up to 128 ports on M1 modules VLAN DMAC e1/ vlan 10 FE SoC Dest Port 10 router_mac internal_channel (e3/1-8,e4/1-8) EtherChannel Hash Function hash_input (from packet) select_member_port 1 4 Fabric F1 2 Fabric 3 M1 Fabric Programming of all F1 forwarding engines Replication 6 VOQs Replication e3/6 5 FE e3/5 7 9 FE VOQs Replication Replication e3/8 e3/7 e3/4 e3/3 e3/2 e3/1 8 Ingress MAC: VLAN DMAC Dest Port 10 router_mac L3_lookup Routing: DIP Next Hop server_2_mac (v20) Egress MAC: VLAN DMAC 20 server_2_mac e2/1 Dest Port 10 e2/ vlan 20 FE SoC Fabric F1 Fabric Fabric Modules M1 Fabric VOQs FE FE VOQs Replication Replication Replication Replication e4/8 e4/7 e4/6 e4/5 e4/4 e4/3 e4/2 e4/1 Programming of all M1 forwarding engines interface vlan 10 ip address /24! interface vlan 20 ip address /24 68
55 Agenda Chassis Architecture Supervisor and I/O Module Architecture Forwarding Architecture Fabric Architecture I/O Module Queuing Layer 2 Forwarding IP Forwarding IP Multicast Forwarding Classification NetFlow Conclusion 70
56 IP Multicast Forwarding Forwarding tables built on control plane using multicast protocols PIM-SM, PIM-SSM, PIM-Bidir, IGMP, MLD Tables downloaded to: Forwarding engine hardware for data plane forwarding (FIB/ADJ) Replication engines for data plane packet replication (Multicast Expansion Table MET) 71
57 IPv4 Multicast FIB TCAM Lookup Ingress multicast packet header Compare lookup key HIT! Generate Lookup Key , , , , , , FIB TCAM Hit in FIB returns result in FIB DRAM Generate TCAM lookup key (source and group IP address) RPF, ADJ Index RPF, ADJ Index RPF, ADJ Index RPF, ADJ Index RPF, ADJ Index FIB DRAM Adj Index Identifies multicast adjacency entry Forwarding MET Index MET Index MET Index MET Index MET Index Adjacency Table Result Return lookup result Replication OIFs OIFs Replication for each OIF in MET block Replicate OIFs OIFs MET MET index used to find OIFs for replication 72
58 Egress Replication IIF Local OIF Distributes multicast replication load among replication engines of all I/O modules with OIFs Input packets get lookup on ingress forwarding engine For OIFs on ingress module, ingress replication engine performs the replication For OIFs on other modules, ingress replication engine replicates a single copy of packet into fabric for those egress modules, fabric replicates as needed Each egress forwarding engine performs lookup to drive replication Replication engine on egress module performs replication for local OIFs Module 1 Fabric Module Replication Local OIFs MET Replication Replication MET MET Fabric Copy Replication Local OIFs MET 73
59 HDR = Packet Headers DATA = Packet Data M1 L3 Multicast Packet Flow Fabric replication 12 Fabric Module 1 Fabric Module 2 Fabric Module 3 VOQ queuing 10 Transmit multicast fabric distribution packet Submit packet headers for lookup 4 Ingress port QoS Receive packet from wire Transmit to fabric Replication 10G MAC Linksec e1/1 Layer 3 Layer 2 Forwarding Module 1 LinkSec decryption 6 L3 multicast FIB lookup Ingress ACL/QoS/ NetFlow lookups 2 L2 ingress snooping lookup Return MET result Layer 3 Layer 2 Forwarding 18 Module 2 Transmit packet on wire Egress port QoS Replication 10G MAC Linksec e2/1 Dequeue multicast distribution copy from fabric VOQs 16 VOQs 9 delivery Replicate for fabric delivery Egress ACL/QoS/ NetFlow lookups 17 7 L2 egress snooping lookup Replicate for local OIF Submit packet headers for egress lookups LinkSec encryption 74
60 HDR = Packet Headers DATA = Packet Data F2 L3 Multicast Packet Flow 9 Fabric replication 8 Transmit multicast fabric distribution packet Fabric Module 1 Fabric Module 2 Fabric Module 3 Fabric Module 4 Fabric Module VOQ queuing Replicate for fabric delivery 5 Return MET result 2 Ingress port QoS (VOQ) VOQ e1/1 FE SoC 4 Replicate for local Module 1 Receive packet from wire L2 ingress snooping lookup L3 multicast FIB lookup Ingress ACL/QoS lookups Submit packet headers for lookup 1 3 VOQ e2/1 SoC FE OIF delivery Module 2 11 Egress port QoS 13 Transmit packet on wire 14 VOQ FE SoC e3/1 10 Receive from fabric Egress ACL/QoS lookups and L2 egress snooping lookup for each copy Module
61 Agenda Chassis Architecture Supervisor and I/O Module Architecture Forwarding Architecture Fabric Architecture I/O Module Queuing Layer 2 Forwarding IP Forwarding IP Multicast Forwarding Classification NetFlow Conclusion 76
62 What Is Classification? Matching packets Layer 2, Layer 3, and/or Layer 4 information Used to decide whether to apply a particular policy to a packet Enforce security, QoS, or other policies Some examples: Match TCP/UDP source/destination port numbers to enforce security policy Match destination IP addresses to apply policy-based routing (PBR) Match 5-tuple to apply marking policy Match protocol-type to apply Control Plane Policing (CoPP) etc. 77
63 CL TCAM Lookup ACL Packet header: SIP: DIP: Protocol: TCP SPORT: DPORT: 80 Generate Lookup Key Generate TCAM lookup key SIP DIP Pr SP DP Security ACL ip access-list example permit ip any host deny ip any host deny ip any host permit tcp any any eq 22 deny tcp any any eq 23 deny udp any any eq 514 permit tcp any any eq 80 permit udp any any eq 161 Compare lookup key to CL TCAM entries tcp xxxxxxx xx xx xxx xxx xxx xxx xxxxxxx xx xxx xxx Forwarding Permit Deny Results Comparisons (X = Mask ) xxxxxxx xx xxx xxx xxxxxxx xxxxxxx tcp xxx xxx 8022 xxxxxxx xxxxxxx tcp xxx 23 Deny Permit Deny HIT! xxxxxxx xxxxxxx udp xxx 514 xxxxxxx xxxxxxx tcp xxx 80 xxxxxxx xxxxxxx udp xxx 161 SIP DIP Pr SP DP CL TCAM Hit in CL TCAM returns result in CL SRAM Deny Permit Permit CL SRAM Result Return lookup result Result affects final packet handling 79
64 CL TCAM Lookup QoS Packet header: SIP: DIP: Protocol: TCP SPORT: DPORT: 80 Compare lookup key Comparisons (X = Mask ) HIT! Generate Lookup Key xxxxxxx xx xx xx xxx xxx xxxxxxx xx xx xxx xxx xx xxxxxxx udp tcp xxx xxx xx xxxxxxx tcp xxx xxx xxxxxxx xx tcp xxx 23 CL TCAM Generate TCAM lookup key tcp SIP DIP Pr SP DP SIP DIP Pr SP DP Hit in CL TCAM returns result in CL SRAM ip access-list police permit ip any /24 permit ip any /24 ip access-list remark-dscp-32 permit udp /24 any ip access-list remark-dscp-40 permit tcp /24 any ip access-list remark-prec-3 permit tcp any /24 eq 23 Forwarding Policer ID 1 Policer ID 1 Remark DSCP 32 Remark DSCP 40 Remark IP Prec 3 CL SRAM QoS Classification ACLs Result Return lookup result Results Result affects final packet handling 80
65 Atomic Policy Programming Avoids packet loss during policy updates Enabled by default Atomic programming process: Program new policy in free/available CL TCAM entries Enable new policy by swapping the ACL label on interface Free CL TCAM resources used by previous policy 82
66 Atomic Policy Programming Cont. To support atomic programming, software reserves 50% of available TCAM If insufficient resources available, system returns an error and no modifications made in hardware Failed to complete Verification: Tcam will be over used, please turn off atomic update Disable with no platform access-list update atomic Disabling may be necessary for very large ACL configurations Atomic programming attempted but not mandatory User can disable atomic programming and perform update non-atomically (assuming ACL fits in CL TCAM) Default ACL result (deny by default) returned for duration of reprogramming Use [no] hardware access-list update default-result permit to control default result 83
67 Classification Configuration Sessions Two ways to configure ACL/QoS policies: Normal configuration mode (config terminal) Configuration applied immediately line by line Recommended only for small ACL/QoS configurations, or non-data-plane ACL configuration Session config mode (config session) Configuration only applied after commit command issued Recommended for large ACL/QoS configurations Config session mode also provides verify facility to dry-run the configuration against available system resources No change to existing hardware configuration after verification (regardless of verification result) 84
68 Agenda Chassis Architecture Supervisor and I/O Module Architecture Forwarding Architecture Fabric Architecture I/O Module Queuing Layer 2 Forwarding IP Forwarding IP Multicast Forwarding Classification NetFlow Conclusion 85
69 NetFlow on Nexus 7000 NetFlow collects flow data for packets traversing forwarding engines Per-interface full and sampled NetFlow provided by M1 module hardware M1 M1 M1 F1 F1 M1 F1 F1 F2 F2 Bridged Yes Yes No No No** Routed Yes Yes Yes* Yes* No** * From release 5.2(1) ** Hardware supports ingress sampled NetFlow Each M1 module maintains independent NetFlow table 512K hardware entries per forwarding engine Hardware NetFlow entry creation CPU not involved in NetFlow entry creation/update 86
70 Full vs. Sampled NetFlow NetFlow configured per-direction and per-interface Ingress and/or egress on per-interface basis Each interface can collect full or sampled flow data Full NetFlow: Accounts for every packet of every flow on interface, up to capacity of NetFlow table Sampled NetFlow: Accounts for M in N packets on interface, up to capacity of NetFlow table 87
71 Sampled NetFlow Details Random packet-based sampling M:N sampling: Out of N consecutive packets, select M consecutive packets and account only for those flows in the hardware NetFlow table Sampled flows aged and exported from NetFlow table normally Advantages Reduces NetFlow table utilization Reduces CPU load on switch and collector Disadvantages Some flows may not be accounted Collector extrapolates total traffic load based on configured sampling rate 88
72 Netflow Data Export (NDE) Process of exporting statistics data from network devices to a collector Allows long-term baselining, trending, and analysis of NetFlow data Exported data sent via UDP Variety of export formats exist Exported data and format of records varies from version to version 89
73 NetFlow Data Export Process To NetFlow Collector Generate NetFlow v5 or v9 export packets M1 Module via Inband Fabric ASIC VOQs Supervisor LC CPU NetFlow Table Aged Flows Forwarding Hardware Flow Creation M1 Module Main CPU Switched EOBC LC CPU Aged Flows NetFlow Table Forwarding Hardware Flow Creation via mgmt0 Mgmt Enet To NetFlow Collector M1 Module LC CPU NetFlow Table Aged Flows Forwarding Hardware Flow Creation 90
74 Agenda Chassis Architecture Supervisor and I/O Module Architecture Forwarding Architecture Fabric Architecture I/O Module Queuing Layer 2 Forwarding IP Forwarding IP Multicast Forwarding Classification NetFlow Conclusion 91
75 Nexus 7000 Architecture Summary I/O Modules Future-proofed chassis designs with density and airflow options Control plane protocols, system and network management Supervisor Chassis Variety of front-panel interface and transceiver types with hardware-based forwarding and services, including unicast/multicast, bridging/routing, ACL/QoS classification, and NetFlow statistics High-bandwidth fabric to interconnect I/O modules and provide investment protection Fabrics 92
76 Conclusion You should now have a thorough understanding of the Nexus 7000 switching architecture, I/O module design, packet flows, and key forwarding engine functions Any questions? 93 93
77 Complete Your Online Session Evaluation Give us your feedback and you could win fabulous prizes. Winners announced daily. Receive 20 Passport points for each session evaluation you complete. Complete your session evaluation online now (open a browser through our wireless network to access our portal) or visit one of the Internet stations throughout the Convention Center. Don t forget to activate your Cisco Live Virtual account for access to all session material, communities, and on-demand and live activities throughout the year. Activate your account at the Cisco booth in the World of Solutions or visit 95
78 Final Thoughts Get hands-on experience with the Walk-in Labs located in World of Solutions, booth 1042 Come see demos of many key solutions and products in the main Cisco booth 2924 Visit after the event for updated PDFs, ondemand session videos, networking, and more! Follow Cisco Live! using social media: Facebook: Twitter: LinkedIn Group: 9
79 97
Cisco Nexus 7000 Switch Architecture
Cisco Nexus 7000 Switch Architecture BRKARC-3470 BRKARC-3470 2013 Cisco and/or its affiliates. All rights reserved. Cisco Public 2 Session Goal To provide a thorough understanding of the Cisco Nexus 7000
Cisco Nexus 7000 Hardware Architecture BRKARC-3470
Cisco Nexus 7000 Hardware Architecture BRKARC-3470 Session Goal To provide you with a thorough understanding of the Cisco Nexus 7000 switching architecture, supervisor, fabric, and I/O module design, packet
Implementing Cisco Data Center Unified Fabric Course DCUFI v5.0; 5 Days, Instructor-led
Implementing Cisco Data Center Unified Fabric Course DCUFI v5.0; 5 Days, Instructor-led Course Description The Implementing Cisco Data Center Unified Fabric (DCUFI) v5.0 is a five-day instructor-led training
Cisco 7600 Series Route Switch Processor 720
Cisco 7600 Series Route Switch Processor 720 Product Overview The Cisco 7600 Series Route Switch Processor 720 (RSP 720) is specifically designed to deliver high scalability, performance, and fast convergence
Cisco Integrators Cisco Partners installing and implementing the Cisco Catalyst 6500 Series Switches
Implementing Cisco Catalyst 6500 Series Switches (RSCAT6K) Fast Lane is proud to be once again on the cutting edge with this intensive 3-day Authorized course on the latest features and functionality of
NX-OS and Cisco Nexus Switching
NX-OS and Cisco Nexus Switching Next-Generation Data Center Architectures Kevin Corbin, CCIE No. 11577 Ron Fuller, CCIE No. 5851 David Jansen, CCIE No. 5952 Cisco Press 800 East 96th Street Indianapolis,
DCUFI - Implementing Cisco Data Center Unified Fabric v5.0
DCUFI - Implementing Cisco Data Center Unified Fabric v5.0 Eğitim Tipi ve Süresi: 5 Days VILT 5 Day VILT DCUFI - Implementing Cisco Data Center Unified Fabric v5.0 Learn to use NX-OS versions 6.1(2) and
Cisco FabricPath Technology and Design
Cisco Technology and Design 2 Agenda Introduction to Concepts Technology vs Trill Designs Conclusion 3 Introduction to By Francois Tallet 5 Why Layer 2 in the Data Centre? Some Applications / Protocols
Ethernet Fabric Requirements for FCoE in the Data Center
Ethernet Fabric Requirements for FCoE in the Data Center Gary Lee Director of Product Marketing [email protected] February 2010 1 FCoE Market Overview FC networks are relatively high cost solutions
基 於 SDN 與 可 程 式 化 硬 體 架 構 之 雲 端 網 路 系 統 交 換 器
基 於 SDN 與 可 程 式 化 硬 體 架 構 之 雲 端 網 路 系 統 交 換 器 楊 竹 星 教 授 國 立 成 功 大 學 電 機 工 程 學 系 Outline Introduction OpenFlow NetFPGA OpenFlow Switch on NetFPGA Development Cases Conclusion 2 Introduction With the proposal
Choosing Tap or SPAN for Data Center Monitoring
Choosing Tap or SPAN for Data Center Monitoring Technical Brief Key Points Taps are passive, silent, and deliver a perfect record of link traffic, but require additional hardware and create a point of
20 GE + 4 GE Combo SFP + 2 10G Slots L3 Managed Stackable Switch
GTL-2691 Version: 1 Modules are to be ordered separately. 20 GE + 4 GE Combo SFP + 2 10G Slots L3 Managed Stackable Switch The LevelOne GEL-2691 is a Layer 3 Managed switch with 24 x 1000Base-T ports associated
Migrate from Cisco Catalyst 6500 Series Switches to Cisco Nexus 9000 Series Switches
Migration Guide Migrate from Cisco Catalyst 6500 Series Switches to Cisco Nexus 9000 Series Switches Migration Guide November 2013 2013 Cisco and/or its affiliates. All rights reserved. This document is
6/8/2011. Document ID: 12023. Contents. Introduction. Prerequisites. Requirements. Components Used. Conventions. Introduction
Page 1 of 9 Products & Services Understanding EtherChannel Load Balancing and Redundancy on Catalyst Switches Document ID: 12023 Contents Introduction Prerequisites Requirements Components Used Conventions
CCNA DATA CENTER BOOT CAMP: DCICN + DCICT
CCNA DATA CENTER BOOT CAMP: DCICN + DCICT COURSE OVERVIEW: In this accelerated course you will be introduced to the three primary technologies that are used in the Cisco data center. You will become familiar
- Multiprotocol Label Switching -
1 - Multiprotocol Label Switching - Multiprotocol Label Switching Multiprotocol Label Switching (MPLS) is a Layer-2 switching technology. MPLS-enabled routers apply numerical labels to packets, and can
High Performance 10Gigabit Ethernet Switch
BDCOM S3900 Switch High Performance 10Gigabit Ethernet Switch BDCOM S3900 is a standard L3 congestion-less switch series, which are capable of multi-layer switching and wire-speed route forwarding. Its
Chapter 7 Configuring Trunk Groups and Dynamic Link Aggregation
Chapter 7 Configuring Trunk Groups and Dynamic Link Aggregation This chapter describes how to configure trunk groups and 802.3ad link aggregation. Trunk groups are manually-configured aggregate links containing
Configuring NetFlow. Information About NetFlow. NetFlow Overview. Send document comments to [email protected]. CHAPTER
CHAPTER 19 This chapter describes how to configure the NetFlow feature on Cisco NX-OS devices. This chapter includes the following sections: Information About NetFlow, page 19-1 Licensing Requirements
Configuring Flexible NetFlow
CHAPTER 62 Note Flexible NetFlow is only supported on Supervisor Engine 7-E, Supervisor Engine 7L-E, and Catalyst 4500X. Flow is defined as a unique set of key fields attributes, which might include fields
Fiber Channel Over Ethernet (FCoE)
Fiber Channel Over Ethernet (FCoE) Using Intel Ethernet Switch Family White Paper November, 2008 Legal INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR
Steve Worrall Systems Engineer. [email protected]
Steve Worrall Systems Engineer [email protected] Agenda 100GbE Load sharing/link aggregation Foundry Direct Routing 2 100 Gigabit Ethernet 3 Current Status PAR approved, 802.3ba task force set up
Configuring Denial of Service Protection
24 CHAPTER This chapter contains information on how to protect your system against Denial of Service (DoS) attacks. The information covered in this chapter is unique to the Catalyst 6500 series switches,
Virtual PortChannels: Building Networks without Spanning Tree Protocol
. White Paper Virtual PortChannels: Building Networks without Spanning Tree Protocol What You Will Learn This document provides an in-depth look at Cisco's virtual PortChannel (vpc) technology, as developed
Agenda. sflow intro. sflow architecture. sflow config example. Summary
sflow Features Agenda sflow intro. sflow architecture sflow config example Summary 1 What is sflow? sflow is a technology for monitoring traffic in data networks containing switches and routers. S9700
Configuring NetFlow. Information About NetFlow. NetFlow Overview. Send document comments to [email protected]. CHAPTER
CHAPTER 16 This chapter describes how to configure the NetFlow feature on Cisco NX-OS devices. This chapter includes the following sections: Information About NetFlow, page 16-1 Licensing Requirements
Chapter 3. Enterprise Campus Network Design
Chapter 3 Enterprise Campus Network Design 1 Overview The network foundation hosting these technologies for an emerging enterprise should be efficient, highly available, scalable, and manageable. This
Improving Quality of Service
Improving Quality of Service Using Dell PowerConnect 6024/6024F Switches Quality of service (QoS) mechanisms classify and prioritize network traffic to improve throughput. This article explains the basic
Cisco Nexus 7000 Series Supervisor Module
Cisco Nexus 7000 Series Supervisor Module The Cisco Nexus 7000 Series Supervisor Module (Figure 1) scales the control plane and data plane services for the Cisco Nexus 7000 Series system in scalable data
"Charting the Course...
Description "Charting the Course... Course Summary Interconnecting Cisco Networking Devices: Accelerated (CCNAX), is a course consisting of ICND1 and ICND2 content in its entirety, but with the content
TRILL for Service Provider Data Center and IXP. Francois Tallet, Cisco Systems
for Service Provider Data Center and IXP Francois Tallet, Cisco Systems 1 : Transparent Interconnection of Lots of Links overview How works designs Conclusion 2 IETF standard for Layer 2 multipathing Driven
NetFlow/IPFIX Various Thoughts
NetFlow/IPFIX Various Thoughts Paul Aitken & Benoit Claise 3 rd NMRG Workshop on NetFlow/IPFIX Usage in Network Management, July 2010 1 B #1 Application Visibility Business Case NetFlow (L3/L4) DPI Application
Configuring NetFlow-lite
CHAPTER 55 Note NetFlow-lite is only supported on Catalyst 4948E Ethernet Switch. This chapter describes how to configure NetFlow-lite on the Catalyst 4948E switch. NetFlow-lite provides traffic monitoring
Cisco Catalyst 4500-X Series Switch Family
Product Bulletin Cisco Catalyst 4500-X Series Fixed 10 Gigabit Ethernet Aggregation Switch PB696811 Overview Cisco Catalyst 4500-X Series Switch (Figure 1) is a fixed aggregation switch that delivers best-in-class
Feature Support Cisco 2960 Cisco 2960S Brocade ICX 6450 Brocade ICX 6430 1 GE SFP, 2 10GE SFP+, 4 1GE SFP, 2 DUAL PURPOSE PORTS, 1GE OR SFP
Feature Support Cisco 2960 Cisco 2960S Brocade ICX 6450 Brocade ICX 6430 Uplinks 1 GE SFP, 2 10GE SFP+, 4 1GE SFP, 2 DUAL PURPOSE PORTS, 1GE OR SFP 40G Stack bandwidth via std 10G ports 2x10G* Fiber aggregation
Course. Contact us at: Information 1/8. Introducing Cisco Data Center Networking No. Days: 4. Course Code
Information Price Course Code Free Course Introducing Cisco Data Center Networking No. Days: 4 No. Courses: 2 Introducing Cisco Data Center Technologies No. Days: 5 Contact us at: Telephone: 888-305-1251
How To Learn Cisco Cisco Ios And Cisco Vlan
Interconnecting Cisco Networking Devices: Accelerated Course CCNAX v2.0; 5 Days, Instructor-led Course Description Interconnecting Cisco Networking Devices: Accelerated (CCNAX) v2.0 is a 60-hour instructor-led
Cisco Certified Network Associate Exam. Operation of IP Data Networks. LAN Switching Technologies. IP addressing (IPv4 / IPv6)
Cisco Certified Network Associate Exam Exam Number 200-120 CCNA Associated Certifications CCNA Routing and Switching Operation of IP Data Networks Operation of IP Data Networks Recognize the purpose and
Catalyst 6500 Architecture
Catalyst 6500 Architecture 2 Session Goal To provide you with a thorough understanding of the Catalyst 6500 switching architecture, packet flow, forwarding engine functions, and key feature operations.
Cisco 7600 Series Routers Cisco 7600 Series: Ethernet Services 20G Line Cards for Carrier Ethernet
. Data Sheet Cisco 7600 Series Routers Cisco 7600 Series: Ethernet Services 20G Line Cards for Carrier Ethernet The Cisco 7600 Series Ethernet Services 20 Gbps (ES20) Line Cards utilize an extensible design
Course Contents CCNP (CISco certified network professional)
Course Contents CCNP (CISco certified network professional) CCNP Route (642-902) EIGRP Chapter: EIGRP Overview and Neighbor Relationships EIGRP Neighborships Neighborship over WANs EIGRP Topology, Routes,
Cisco Nexus 5548P Switch Architecture
Cisco Nexus 5548P Switch Architecture What You Will Learn Cisco introduced Nexus 5000 Series Switches both as high-bandwidth, low-latency, access-layer switches for rack deployment and as the basis for
Introducing Basic MPLS Concepts
Module 1-1 Introducing Basic MPLS Concepts 2004 Cisco Systems, Inc. All rights reserved. 1-1 Drawbacks of Traditional IP Routing Routing protocols are used to distribute Layer 3 routing information. Forwarding
Data Networking and Architecture. Delegates should have some basic knowledge of Internet Protocol and Data Networking principles.
Data Networking and Architecture The course focuses on theoretical principles and practical implementation of selected Data Networking protocols and standards. Physical network architecture is described
Cisco Data Center Network Manager Release 5.1 (LAN)
Cisco Data Center Network Manager Release 5.1 (LAN) Product Overview Modern data centers are becoming increasingly large and complex. New technology architectures such as cloud computing and virtualization
VMDC 3.0 Design Overview
CHAPTER 2 The Virtual Multiservice Data Center architecture is based on foundation principles of design in modularity, high availability, differentiated service support, secure multi-tenancy, and automated
Configuring Quality of Service
CHAPTER 37 QoS functionality on Supervisor Engine 6-E, Supervisor Engine 6L-E, Catalyst 49M, and Catalyst 4948E are equivalent. This chapter describes how to configure quality of service (QoS) by using
VXLAN: Scaling Data Center Capacity. White Paper
VXLAN: Scaling Data Center Capacity White Paper Virtual Extensible LAN (VXLAN) Overview This document provides an overview of how VXLAN works. It also provides criteria to help determine when and where
CCNA R&S: Introduction to Networks. Chapter 5: Ethernet
CCNA R&S: Introduction to Networks Chapter 5: Ethernet 5.0.1.1 Introduction The OSI physical layer provides the means to transport the bits that make up a data link layer frame across the network media.
FWSM introduction Intro 5/1
Intro 5/0 Content: FWSM introduction Requirements for FWSM 3.2 How the Firewall Services Module Works with the Switch Using the MSFC Firewall Mode Overview Stateful Inspection Overview Security Context
Virtual Networking Features of the VMware vnetwork Distributed Switch and Cisco Nexus 1000V Series Switches
Virtual Networking Features of the vnetwork Distributed Switch and Cisco Nexus 1000V Series Switches What You Will Learn With the introduction of ESX, many virtualization administrators are managing virtual
IMPLEMENTING CISCO SWITCHED NETWORKS V2.0 (SWITCH)
IMPLEMENTING CISCO SWITCHED NETWORKS V2.0 (SWITCH) COURSE OVERVIEW: Implementing Cisco Switched Networks (SWITCH) v2.0 is a five-day instructor-led training course developed to help students prepare for
Implementing Cisco Quality of Service QOS v2.5; 5 days, Instructor-led
Implementing Cisco Quality of Service QOS v2.5; 5 days, Instructor-led Course Description Implementing Cisco Quality of Service (QOS) v2.5 provides learners with in-depth knowledge of QoS requirements,
CS 78 Computer Networks. Internet Protocol (IP) our focus. The Network Layer. Interplay between routing and forwarding
CS 78 Computer Networks Internet Protocol (IP) Andrew T. Campbell [email protected] our focus What we will lean What s inside a router IP forwarding Internet Control Message Protocol (ICMP) IP
Understanding Quality of Service on the Catalyst 6500 Switch
. White Paper Understanding Quality of Service on the Catalyst 6500 Switch Carl Solder CCIE #2416 Technical Marketing Engineer Internetworking Systems Business Unit Patrick Warichet CCIE #14218 Technical
Juniper / Cisco Interoperability Tests. August 2014
Juniper / Cisco Interoperability Tests August 2014 Executive Summary Juniper Networks commissioned Network Test to assess interoperability, with an emphasis on data center connectivity, between Juniper
Chapter 4 Rate Limiting
Chapter 4 Rate Limiting HP s rate limiting enables you to control the amount of bandwidth specific Ethernet traffic uses on specific interfaces, by limiting the amount of data the interface receives or
Cisco Discovery 3: Introducing Routing and Switching in the Enterprise 157.8 hours teaching time
Essential Curriculum Computer Networking II Cisco Discovery 3: Introducing Routing and Switching in the Enterprise 157.8 hours teaching time Chapter 1 Networking in the Enterprise-------------------------------------------------
Interconnecting Cisco Networking Devices, Part 2 **Part of CCNA Route/Switch**
Course: Interconnecting Cisco Networking Devices, Part 2 Duration: 5 Day Hands-On Lab & Lecture Course Price: $ 3,295.00 Learning Credits: 33 Certification: CCNA Route/Switch Description: The Interconnecting
How To Balance On A Cisco Catalyst Switch With The Etherchannel On A Fast Ipv2 (Powerline) On A Microsoft Ipv1 (Powergen) On An Ipv3 (Powergadget) On Ipv4
Cisco - Understanding EtherChannel Load Balancing and Redundancy on Catalyst Switch...Page 1 of 10 Understanding EtherChannel Load Balancing and Redundancy on Catalyst Switches Document ID: 12023 Contents
100-101: Interconnecting Cisco Networking Devices Part 1 v2.0 (ICND1)
100-101: Interconnecting Cisco Networking Devices Part 1 v2.0 (ICND1) Course Overview This course provides students with the knowledge and skills to implement and support a small switched and routed network.
Cisco IOS Flexible NetFlow Technology
Cisco IOS Flexible NetFlow Technology Last Updated: December 2008 The Challenge: The ability to characterize IP traffic and understand the origin, the traffic destination, the time of day, the application
Licensing Cisco NX-OS Software Features
Licensing Cisco NX-OS Software This publication contains information related to licensing types, options, procedures, installation, and management for the Cisco NX-OS software. Cisco Data Center Network
SDN. WHITE PAPER Intel Ethernet Switch FM6000 Series - Software Defined Networking. Recep Ozdag Intel Corporation
WHITE PAPER Intel Ethernet Switch FM6000 Series - Software Defined Networking Intel Ethernet Switch FM6000 Series - Software Defined Networking Recep Ozdag Intel Corporation Software Defined Networking
CCT vs. CCENT Skill Set Comparison
Operation of IP Data Networks Recognize the purpose and functions of various network devices such as Routers, Switches, Bridges and Hubs Select the components required to meet a given network specification
MPLS Concepts. Overview. Objectives
MPLS Concepts Overview This module explains the features of Multi-protocol Label Switching (MPLS) compared to traditional ATM and hop-by-hop IP routing. MPLS concepts and terminology as well as MPLS label
Lab Testing Summary Report
Lab Testing Summary Report January 2015 Report SR140730F Product Category: Supervisor Engine Vendor Tested: Product Tested: Catalyst 4500E Supervisor Engine 8-E Key findings and conclusions: Tests achieved
Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version 1.0.0. 613-001339 Rev.
Management Software AT-S106 Web Browser User s Guide For the AT-GS950/48 Gigabit Ethernet Smart Switch Version 1.0.0 613-001339 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of
200-101: Interconnecting Cisco Networking Devices Part 2 v2.0 (ICND2)
200-101: Interconnecting Cisco Networking Devices Part 2 v2.0 (ICND2) Course Overview This course provides students with the knowledge and skills to successfully install, operate, and troubleshoot a small
Configuring a Load-Balancing Scheme
This module contains information about Cisco Express Forwarding and describes the tasks for configuring a load-balancing scheme for Cisco Express Forwarding traffic. Load-balancing allows you to optimize
640-816: Interconnecting Cisco Networking Devices Part 2 v1.1
640-816: Interconnecting Cisco Networking Devices Part 2 v1.1 Course Introduction Course Introduction Chapter 01 - Small Network Implementation Introducing the Review Lab Cisco IOS User Interface Functions
Sup720 Hardware Assisted Features
Sup720 Hardware Assisted Features 1 IPV6 Switching on Supervisor 720 IPV6 IPV6 SOFTWARE SOFTWARE FEATURES FEATURES IPV6 IPV6 HARDWARE HARDWARE FEATURES FEATURES 128K 128K FIB FIB entries entries IPV6 IPV6
WAN Topologies MPLS. 2006, Cisco Systems, Inc. All rights reserved. Presentation_ID.scr. 2006 Cisco Systems, Inc. All rights reserved.
MPLS WAN Topologies 1 Multiprotocol Label Switching (MPLS) IETF standard, RFC3031 Basic idea was to combine IP routing protocols with a forwarding algoritm based on a header with fixed length label instead
WiNG 5.X How To. Policy Based Routing Cache Redirection. Part No. TME-05-2012-01 Rev. A
WiNG 5.X How To Policy Based Routing Cache Redirection Part No. TME-05-2012-01 Rev. A MOTOROLA, MOTO, MOTOROLA SOLUTIONS and the Stylized M Logo are trademarks or registered trademarks of Motorola Trademark
Configuring Auto Policy-Based Routing
This chapter describes how to configure the Auto Policy-Based Routing (PBR) feature on the Citrix NetScaler Application Delivery Controller (ADC) appliance to ensure that return traffic from the real server
Chapter 6 Configuring IP
Chapter 6 Configuring IP This chapter describes the Internet Protocol (IP) parameters on HP ProCurve routing switches and switches and how to configure them. After you add IP addresses and configure other
"Charting the Course... ... to Your Success!" QOS - Implementing Cisco Quality of Service 2.5 Course Summary
Course Summary Description Implementing Cisco Quality of Service (QOS) v2.5 provides learners with in-depth knowledge of QoS requirements, conceptual models such as best effort, IntServ, and DiffServ,
Interconnecting Cisco Networking Devices Part 2
Interconnecting Cisco Networking Devices Part 2 Course Number: ICND2 Length: 5 Day(s) Certification Exam This course will help you prepare for the following exam: 640 816: ICND2 Course Overview This course
Configuring Network Security with ACLs
CHAPTER 46 This chapter describes how to use access control lists (ACLs) to configure network security on the Catalyst 4500 series switches. The Catalyst 4500 series switch supports time-based ACLs. For
Network Analysis Modules
CHAPTER 6 This chapter describes the (NAMs) and contains the following sections: Network Analysis Module (WS-SVC-NAM-1), page 6-2 Network Analysis Module (WS-SVC-NAM-2), page 6-4 NAMs monitor and analyze
ANZA Formación en Tecnologías Avanzadas
Temario INTRODUCING CISCO DATA CENTER TECHNOLOGIES (DCICT) DCICT is the 2nd of the introductory courses required for students looking to achieve the Cisco Certified Network Associate certification. This
Chapter 2 Quality of Service (QoS)
Chapter 2 Quality of Service (QoS) Software release 06.6.X provides the following enhancements to QoS on the HP 9304M, HP 9308M, and HP 6208M-SX routing switches. You can choose between a strict queuing
Description: To participate in the hands-on labs in this class, you need to bring a laptop computer with the following:
Course: Implementing Cisco Quality of Service Duration: 5 Day Hands-On Lab & Lecture Course Price: $ 3,395.00 Learning Credits: 34 Description: Implementing Cisco Quality of Service (QOS) v2.5 provides
Procedure: You can find the problem sheet on Drive D: of the lab PCs. Part 1: Router & Switch
University of Jordan Faculty of Engineering & Technology Computer Engineering Department Computer Networks Laboratory 907528 Lab. 2 Network Devices & Packet Tracer Objectives 1. To become familiar with
Advanced VSAT Solutions Bridge Point-to-Multipoint (BPM) Overview
2114 West 7 th Street Tempe, AZ 85281 USA Voice +1.480.333.2200 E-mail [email protected] Web www.comtechefdata.com Advanced VSAT Solutions Bridge Point-to-Multipoint (BPM) Overview January 2014 2014
ALLNET ALL8944WMP Layer 2 Management 24 Port Giga PoE Current Sharing Switch
ALLNET ALL8944WMP Layer 2 Management 24 Port Giga PoE Current Sharing Switch 24-Port Giga PoE Current Sharing Pv6 and IPv4 Dual Protocol SNMP v1/v2c/v3 SSH version 2.0 Authentication TACACS+ Jumbo Frames
DCICT: Introducing Cisco Data Center Technologies
DCICT: Introducing Cisco Data Center Technologies Description DCICN and DCICT will introduce the students to the Cisco technologies that are deployed in the Data Center: unified computing, unified fabric,
How To Switch In Sonicos Enhanced 5.7.7 (Sonicwall) On A 2400Mmi 2400Mm2 (Solarwall Nametra) (Soulwall 2400Mm1) (Network) (
You can read the recommendations in the user, the technical or the installation for SONICWALL SWITCHING NSA 2400MX IN SONICOS ENHANCED 5.7. You'll find the answers to all your questions on the SONICWALL
Router and Routing Basics
Router and Routing Basics Malin Bornhager Halmstad University Session Number 2002, Svenska-CNAP Halmstad University 1 Routing Protocols and Concepts CCNA2 Routing and packet forwarding Static routing Dynamic
Cisco ubr7200-npe-g2 Network Processing Engine
Cisco ubr7200-npe-g2 Network Processing Engine Product Overview With the introduction of the ubr7200-npe-g2 Network Processing Engine, service providers can now take advantage of the enhanced performance
Configuring Cisco Nexus 5000 Switches Course DCNX5K v2.1; 5 Days, Instructor-led
Configuring Cisco Nexus 5000 Switches Course DCNX5K v2.1; 5 Days, Instructor-led Course Description Configuring Cisco Nexus 5000 Switches (DCNX5K) v2.1 is a 5-day ILT training program that is designed
Appendix A Remote Network Monitoring
Appendix A Remote Network Monitoring This appendix describes the remote monitoring features available on HP products: Remote Monitoring (RMON) statistics All HP products support RMON statistics on the
Configuring QoS and Per Port Per VLAN QoS
27 CHAPTER This chapter describes how to configure quality of service (QoS) by using automatic QoS (auto-qos) commands or by using standard QoS commands on a Catalyst 45 series switch. It also describes
Configuring IPS High Bandwidth Using EtherChannel Load Balancing
Configuring IPS High Bandwidth Using EtherChannel Load Balancing This guide helps you to understand and deploy the high bandwidth features available with IPS v5.1 when used in conjunction with the EtherChannel
VMware Virtual SAN 6.2 Network Design Guide
VMware Virtual SAN 6.2 Network Design Guide TECHNICAL WHITE PAPER APRIL 2016 Contents Intended Audience... 2 Overview... 2 Virtual SAN Network... 2 Physical network infrastructure... 3 Data center network...
Leveraging Advanced Load Sharing for Scaling Capacity to 100 Gbps and Beyond
Leveraging Advanced Load Sharing for Scaling Capacity to 100 Gbps and Beyond Ananda Rajagopal Product Line Manager Service Provider Solutions Foundry Networks [email protected] Agenda 2 Why Load
FortiSwitch. Data Center Switches. Highlights. High-performance and resilient managed data center switch. Key Features & Benefits.
DATA SHEET FortiSwitch Data Center Switches FortiSwitch FortiSwitch 1024D, 1048D and 3032D Data Center Switches FortiSwitch Data Center switches deliver outstanding throughput, resiliency and scalability
Configuring MPLS QoS
CHAPTER 45 This chapter describes how to configure Multiprotocol Label Switching (MPLS) quality of service (QoS) in Cisco IOS Release 12.2SX. For complete syntax and usage information for the commands
Netflow Overview. PacNOG 6 Nadi, Fiji
Netflow Overview PacNOG 6 Nadi, Fiji Agenda Netflow What it is and how it works Uses and Applications Vendor Configurations/ Implementation Cisco and Juniper Flow-tools Architectural issues Software, tools
Juniper Networks EX Series/ Cisco Catalyst Interoperability Test Results. May 1, 2009
Juniper Networks EX Series/ Cisco Catalyst Interoperability Test Results May 1, 2009 Executive Summary Juniper Networks commissioned Network Test to assess interoperability between its EX4200 and EX8208
