Rodwell. Autoclave Range. Rodwell Scientific Instruments: UK Manufactured since litres, vertical & horizontal loading
|
|
|
- Britney Fields
- 10 years ago
- Views:
Transcription
1 Rodwell Rodwell Scientific Instruments: Autoclave Range UK Manufactured since litres, vertical & horizontal loading
2 Why specify a Rodwell Autoclave? Make the smart choice Autoclaves are often overlooked in the central role they play in the operation of the modern laboratory. The vast majority of laboratories simply cannot function without one. Therefore, it is the smart buyer who gives such careful consideration to the single piece of equipment so essential to the efficient every day to day running of a laboratory. Spending more will cost you less as a Rodwell autoclave will outlive most competition many times over.. Everybody is under constant pressure to reduce costs and save money. However, how smart is the buyer who saves money on the initial purchase, only to incur additional costs in extra maintenance; breakdowns which will ultimately result in the early replacement of an instrument? Rodwell autoclaves tend to cost more than most of the competition but vast savings are quickly realised due to reduced operating, service and maintenance costs. Not to mention the knock-on costs to the laboratory when an autoclave breaks down. A reliable autoclave not only means an efficient laboratory, but a happier workforce too, which in turn saves money! You get what you pay for? This is certainly the case for cheaper equipment for the reasons mentioned above, but with Rodwell Autoclaves you do not get what you pay for; you get more! The highest quality materials High pressure pipe work and compression fittings for easy maintenance Proven materials, systems and technology Control system with more standard features Solid construction ensuring many years reliable service Upgradeable technology Sensible, practical design as opposed to aesthetics Safety locks + lock detection systems Diagnostic control system that informs the operator of the nature of any faults for quick and simple fault finding. Support for your autoclave a team obsession Rodwell Scientific Instruments is a division of the Rodwell Engineering Group, a family owned company whose team of engineers have achieved success over the past 50 years simply by doing their best to ensure total customer satisfaction. A Global Business Rodwell Scientific Instruments have been exporting for the past 30 years and have established distributors in many nations all over the world. Our distributors share our commitment for proficient after-sales service, using fully trained engineers with access to the latest technology and total support from the manufacturers they represent. Making full use of modern available technology and the internet has allowed us to develop up-to-date software (optional) which allows the scientist to complete cycles to our technical department for full on-screen diagnosis and set-up recommendations. Expertise Rodwell Engineering Group is a family business founded in Over the years it has expanded to a multi-faceted engineering company though natural growth, acquisition and shrewd investment. Some of Rodwell s acquisitions have a history spanning back nearly 100 years! The company also has extensive property and business interests which ensure financial stability even throughout the most turbulent times. This broad nature of Rodwell Engineering Group s activities plus sound financial foundations ensure that your Rodwell Autoclave is manufactured to the highest engineering standards and can be supported throughout its lifetime. Rodwell Rodwell Scientific Instruments Autoclave manufacturers Rodwell HTB Paper & board Feeders & stackers Rodwell Bayne Compressed Air Engineers Rodwell Precision Engineering Production & Precision Engineers Rodwell Powell Aerospace Engineers & Inspection Rodwell Group Services Central Accounts Property Investment Precision Engineering since
3 Compact Autoclaves Phoenix Benchtop 40 or 60 litres MP25 Control (see page 7) Single phase plug in & play Integral drip tray under each door Bench or trolley mounted Phoenix 40 has capacity for up to 13 x 1L media bottles Can be completely stand alone Condense collector (eliminates need for a plumbed drain service) Model Phoenix 40 Phoenix 60 Chamber Capacity: 40 litres 60 litres Vessel Dimensions (mm): 350Ø x 460 deep 350Ø x 600d deep Overall Dimensions (mm): 550w x 790h x 710d 550w x 790h x 860d Monarch 50 or 75 litres Counterbalanced lid for easy opening Angled control panel Exceptionally low loading height (50) Fits most fermentation vessels and bioreactors (75) Additional loading baskets Condense collector (eliminates need for a plumbed drain service) Monarch 50 Features Designed to fit underneath a standard bench Single phase 3kw plug in and play Monarch 75 Features Fits up to 3 loading baskets Powerful 4kw heater Model Monarch 50 Monarch 75 Chamber Capacity: 50 litres 75 litres Vessel Dimensions (mm): 350Ø x 520 deep 350Ø x 780 deep Overall Dimensions (mm): 470w x 840h x 690d 470w x 1100h x 690d 3
4 Medium Capacity Autoclaves Ensign 100 & 125 litres Counterbalanced lid for easy opening Available in electrically heated version or from a piped steam source Formats 1) 6 kw in-chamber heating (100) 2) 9 kw in-chamber heating (100 & 125) 3) Heated from an external steam supply 4) Remote steam heated with generator Hydraulic loading trolley Air ballasting option Drain line condenser for plastic drains Model Ensign 100 Ensign 125 Chamber Capacity: 100 litres 125 litres Vessel Dimensions (mm): 460Ø x 570 deep 460Ø x 723 deep Overall Dimensions (mm): 560w x 1090h x 800d 560w x 1240h x 800d* 560w x 1240h x 1100d** *Without loading step **With loading step Ambassador 100 or 158 litre variants Cost effective hinge / bolt door Integral drip tray under door Fixed seal Formats 1) 6 kw in-chamber heating (100) 2) 9 kw in-chamber heating (100 & 158) 3) Heated by an integrated 9kW steam generator 3) Heated from an external steam supply 4) Double door pass through version available (158L) Loading trolley Air ballasting option Drain line condenser for plastic drains Integrated steam generator Model Ambassador 100 Ambassador 158 Chamber Capacity: 100 litres 158 litres Vessel Dimensions (mm): 460Ø x 610 deep 460Ø x 960 deep Overall Dimensions (mm): 650w x 1240h x 1160d 650w x 1240h x 1310d 4
5 Large Capacity Autoclaves (Round Chambers) Gemini Totally Unique: Two independent autoclaves in one robust frame! 2 x 158 litre vessels 316 litre total capacity Independent control of each chamber Can be used as a clean and dirty autoclave in one frame Integral drip tray under each door Available in electrically heated version or from a piped steam source Integrated steam generator available Hydraulic loading trolley Air ballasting option Drain line condenser for plastic drains Model Gemini 316 Chamber Capacity: 158 litres x 2 Vessel Dimensions (mm): 460Ø x 960 deep (x2) Overall Dimensions (mm): 650w x 1970h x 1310d Sovereign 200 & 250 litre variants Economy round chamber Cost effective hinge / bolt door Integral drip tray under door Available in electrically heated version or from a piped steam source Fixed seal Integrated steam generator available Formats 1) Heated from within the chamber 2) Integral steam generator separate from the chamber 3) Heated from an external steam supply 4) Remote steam heated with generator back-up Loading trolley Air ballasting option Drain line condenser for plastic drains Model Sovereign 200 Sovereign 250 Chamber Capacity: 200 litres 250 litres Vessel Dimensions (mm): 545Ø x 860 deep 545Ø x 1057 deep Overall Dimensions (mm): 830w x 1800h x 1450d 830w x 1800h x 1450d 5
6 Large Capacity Autoclaves (Square Chambers) Crystal 300 litres Square section chamber Cost effective hinge / bolt door Integral drip tray under door Available in electrically heated version or from a piped steam source Fixed seal Integrated steam generator Formats 1) Integral steam generator separate from the chamber 2) Heated from an external steam supply 3) Remote steam heated with generator back-up 4) Double door pass-through version available Loading trolley Air ballasting option Drain line condenser for plastic drains Model Crystal 300 Chamber Capacity: 300 litres Vessel Dimensions (mm): 510w x 510h x 1030d Overall Dimensions (mm): 830w x 1800h x 1450d Sapphire 330, 440, 550, 660 & 770 litre variants Square section chamber Reliable Hoist and Clamp door Fixed seal Integral drip tray under door Accelerated water cooling jacket Compact Integrated steam generator Super fast cycle times! Formats 1) Integral steam generator separate from the chamber 2) Heated from an external steam supply 3) Remote steam heated with generator back-up 4) Double door pass-through version available (550, 660 & 770) 15 min. flash cycle option Loading trolley Air ballasting option Waste discard containers Drain line condenser for plastic drains Steam jacket drying Model Sapphire 330 Sapphire 440 Sapphire 550 Chamber Capacity: 330 litres 440 litres 550 litres Vessel Dimensions (mm): 670w x 670h x 745d 670w x 670h x 936d 670w x 670h x 1099d Overall Dimensions (mm): 980w x 1930h x 1530d 980w x 1930h x 1530d 980w x 1930h x 1530d Model Sapphire 660 Sapphire 770 Chamber Capacity: 660 litres 770 litres Vessel Dimensions (mm): 670w x 670h x 1274d 670w x 670h x 1455d Overall Dimensions (mm): 980w x 1930h x 1750d 980w x 1930h x 1900d 6
7 MP25 Controller & Smartcard The common control system fitted to every autoclave in the Rodwell range. The MP25 has evolved to be one of the finest laboratory instrument control systems on the market today. What sets this system apart from any other control system is that it is totally interchangeable. The same MP25 control system with any Rodwell autoclave: from a bench top to a large square chambered vacuum machine. Total versatility in 25 programs! Standard Features 25 programs Can be programmed and stored by the laboratory supervisor Smart Card Access System Allows programs to be stored and locked off by a supervisor Operator cards give access to pre-programmed cycles only Available with or without operator smartcard access for operator access Load Activated Sterilise Timer (On/Off) prevents the sterilise timer from starting until the chamber and load have reached set point temperature. Free Steam Timer (adjustable by time) Holds the chamber at approximately 100 C (without pressurising) for a pre-determined time during the heating period and allows effective steam penetration into the load. Delayed Start (24 hour clock) Timer option allows the autoclave to be pre-programmed at a predetermined time so the autoclave completes a cycle just before the lab arrives for work the following morning for pre-prepared warm media. Adjustable Stay Warm (on/off) Keeps the chamber warm at the end of the cycle for pourable media. This is adjustable to allow the operator to select the optimum temperature. Instrument Cycles (programs 21 to 24 only) Exhausts the chamber at the end of the cycle for dryer glassware and instruments upon completion. Self Diagnostic Notifies the operator of any faults. The nature of many faults are clearly displayed on the LCD. Sterilise Fault Warning Notifies the operator if there has been a power supply problem or the temperature has not been maintained during the cycle. MP25 Options Post Cycle Drying Programs 17 to 20 can be set to control a post-cycle drying heater (cannot be used with in-chamber heating systems unless auto drain or separate steam generator is specified) Cycle Recorders Cycle recorders are available to record: Load temperature - (single channel) Load & Chamber temperature (2 channel) Load & Chamber temperatures + Pressure (3 channel) Data Printers Provides a hard copy print out of parameters and readings during the cycle (2 or 3 channel available). Chart Recorders A complete range of circular and strip type chart recorders are available to provide a graphical representation of chamber conditions during each cycle. The MP25 will switch on the chart recorder only when a cycle is operating in order to save chart paper. A complete range of anything up to 12 channels are available plus a range of independent graphical recorders (1, 2 or 3 channel available). SmartLog Cycle Data Recording Software The ultimate system for autoclave logging. Enables a personal computer to analyse each autoclave cycle in great detail. The software provides a multi-channel readout including a full graphic profile, and the ability to provide remote diagnostic support. USB Memory Logging For quick and efficient downloading of log data the MP25 is equipped with a USB port for direct data transfer straight to a Rodwell USB Key. The data can then be transferred to a PC for analysis on our SmartLog Software. 7
8 USB SmartLog TM System The MP25 SmartLog system from Rodwell Scientific Instruments is revolutionising the way that autoclave cycle data is collected and analysed. In the past data collection would have been carried out by use of a data printer, which meant regular paper re-fills, replacement ink ribbons and reams of paper reports accumulating on the laboratory manager s desk. Now with our USB SmartLog system instead of large bulky chart recorders, or paper printers, every cycle is automatically stored to memory, which can then be downloaded and analysed in our SmartLog software. Complete Package The SmartLog system, comprises a specially adapted USB memory stick and our SmartLog software package. When connected to our MP25 controller, each time a cycle is carried out, all the cycle information is stored directly to the memory stick. The data files can then be downloaded to the PC for analysis at a later date. The software offers quick and easily analysis identifying any problems which may have occurred during the run. Need something tangible to show auditors? SmartLog can generate a comprehensive customisable report which only has to be printed as and when required for audit purposes. As well as basic time and temperature sampling as with traditional data printers, a complete cycle temperature profile is also displayed giving a graphic representation of the entire cycle. The graph offers various visual options enabling the user to view only what they wish to see. This includes custom probe views, different cycle stages, drying and pressure displays, graphical zoom for more detailed analysis as well as F0 values for food testing laboratories. Traceability The software data cannot be tampered with so is fully compliant for traceability purposes, although can be exported to spreadsheets if required. In addition to help laboratories tackle traceability issues, we now offer a fully automatic barcode batching system for clients with multiple types of waste. This eliminates the need to manually write down exactly when and what has been autoclaved, streamlining the entire autoclave process. Economy All these features are offered in one standard SmartLog package, which comes at a very competitive price, costing less than a standard 2 channel data printer without any ongoing service costs! Diagnostic Support When choosing an autoclave, the back up service is the most serious consideration. With the SmartLog diagnostic features, this package could rapidly become the laboratory manager s best friend. The Engineer s details tab, enables a quick and comprehensive overview of the autoclave s technical functions, saving the engineer lots of troubleshooting time, and reducing overall downtime. In addition the SmartLog software enables users, to cycle files directly to Rodwell technical support, where we can analyse any file on our diagnostic computer giving any user or service agent the benefit of Rodwell technical back up without even being there! This service is completely unique to Rodwell and is all part of our quality after sales care. SmartLog+ Now all the benefits of SmartLog just got better with SmartLog+. In addition to all of the features of the standard system, the + version offers a real time down the wire addition, where all files are recorded in duplicate on an adjoined PC, as well as a real time on screen display of all time and temperature information. 8
9 Options and Features Explained Accelerated Load Cooling Systems Fan Assisted Cooling (Available on all models except Sapphire) Auto-fill Diagram Mains water in Overflow Powerful fans, strategically located, direct a blast of cool air around the chamber which significantly improves cooling times by up to 50%. Water Cooling (Sapphire Only) The most efficient way of cooling. Cold water passes through a complete water jacket surrounding the autoclave chamber, which rapidly cools the chamber and the load. This system is far more effective than cooling coils fitted to some other autoclaves. Air Ballasting Uses compressed air to improve cooling times even further and prevent boil-over and breakages in bottled liquid loads. A silent air compressor and carbon filter pack (for an oil free supply) can be provided if there is no compressed air supply in the laboratory. Heating Systems Diagram Heating Systems In-chamber electric steam heating generates steam from within a water compartment in the bottom of the chamber below the shelf. Electrically Heated by separate steam generator (boiler) (Available of Ambassador, Gemini, Sovereign, Crystal & Sapphire) Steam is generated by means of a steam generator mounted below the autoclave chamber. This includes a high pressure inlet pump which automatically tops up the steam generator during the cycle. Pre-Heated steam generator This works on a similar principle as above. Except the steam generator remains constantly heated providing instant heating of the chamber when a cycle is started. A A The steam generator stands separate from the autoclave for top loading models. More powerful pre-heated steam generators are required for electrically heated liquid vacuum autoclaves. Direct Steam Heated Heating by means of a steam inlet valve from an external steam supply. A saturated supply regulated to a pressure of between 35lb and 70lb at 2.62 bar is required (depending on model requirements). Auto-fill Systems A water supply is required for automatic fill options. The supply must be fed via a break tank, which isolates the chamber from the mains supply to comply with regulations. Manual Fill (available on all models except Sapphire and Crystal) Basic in-chamber heated autoclaves are manual fill for simplicity. No water supply is required for manual fill machines unless a drain line condenser is specified. The MP25 notifies the operator if the chamber is low on water. The autoclave cannot be started unless the chamber has sufficient water. The chamber is simply topped up with a jug of water. Auto-fill for in-chamber heating In-chamber heated autoclaves can be manufactured with a topup system. If the MP25 senses the chamber is low, it sends a signal to a motorised valve which opens to allow the chamber to be topped up from the water supply. Auto-drain and Re-fill for in-chamber heating The chamber dumps all the water from the chamber at the end of the cycle and fills with fresh water when a new cycle is started. Auto-fill for steam generator models Note that automatic fill is standard on autoclaves supplied with a separate steam generator. Water Treatment Systems An industrial grade electronic scale prevention system alters the physical characteristics of minerals within the inlet water supply so they pass through the autoclave without sticking to the chamber or boiler. Inlet Water Filter Industrial grade filter traps most scale and chalk and other large debris from the mains water supply. Vacuum Air Removal Systems Typically the key to good sterilisation results is to remove all the air from within the chamber; particularly on waste and porous loads. By adding a vacuum option this ensures that no air pockets remain in the chamber and that the correct temperatures are achieved. Vacuum systems are also an essential element to drying options. 9
10 Drain Systems Condense Collector (Available for manual fill autoclaves only*) Eliminates the need for a drain service by collecting the condense in a stainless steel container. *Basic manual fill autoclaves are Phoenix, Monarch, Ensign, Ambassador and Gemini. Not suitable for direct steam autoclaves. Drain Line Condenser This option is required if the autoclave is to be connected to a plastic drain service either directly or indirectly. Works by injecting cold water in to the drain if it reaches temperatures over 50 C. There is also a second type of drain line condenser which works like a mini heat exchange and does not require a water supply. Vacuum Break & Filter As the chamber cools a natural vacuum is draw; therefore a vacuum break can be offered completes with a filter to filter the incoming air being drawn back into the chamber. Baskets Our baskets are manufactured using strengthened grade 316 stainless steel wire mesh for optimum durability. All top loading autoclaves are equipped with one basket as standard with extra baskets available as optional. Discard Containers & Systems Laboratory waste must be autoclaved to render it safe prior to disposal. Research has shown that a high efficiency vacuum air removal system is necessary when sterilising waste in solid sided containers with a height of greater than 200mm. However, Rodwell Scientific Instruments offer a unique patented range of discard containers which allows total efficient sterilisation of laboratory waste without the need for a vacuum system. Advantages of the Rodwell Waste Discard Container system are: Simplifies the autoclave by eliminating the need for a vacuum system. Efficient sterilisation of waste by naturally removing air pockets Trivet system catches spillages and helps keep the chamber clean for reduced house keeping The Rodwell Waste Discard Container system is available on all models except the Crystal & Sapphire range. For these units standard solid sided containers and vacuum air removal systems are recommended for sterilising waste. Drain Line Filters (HEPA Filters) Hepa filters are fitted to the autoclave vent to prevent the release of dangerous pathogens into the drain. Rodwell also offers a Hepa filter monitoring system. Condensate Retention Hepa filters are fitted to the autoclave vent to prevent the release of dangerous pathogens into the drain. Chamber Furniture A complete range of shelves, containers & discard systems are available to enhance the performance of your autoclave. Rodwell Scientific Instruments chamber furniture is specifically tailored to maximise space within the chamber. Bespoke furniture can be manufactured on request. Shelves Our shelves are manufactured using rigid punched stainless steel capable of taking the heaviest of loads. All front loading units come equipped with one shelf with extra shelves available as optional. We re here to help. If you d like help or advice choosing the right autoclave please get in touch. Our knowledgeable sales people will do their best to guide you toward the choice that is right for your application and budget. +44 (0) [email protected] 10
11 Options and Features Explained The best after-sales care for your autoclave Every Rodwell Autoclave is manufactured to the highest standards and will provide many years of reliable service if looked after and maintained by an approved, accredited Rodwell engineer. Our service engineers have extensive knowledge and the very latest up-to-date technical information for our equipment, as well as the latest working practices and procedures. To get the very best from your autoclave, it is essential that it is maintained by the people who know your autoclave best - Rodwell trained and accredited engineers or approved Rodwell service agents. They understand your autoclave, care about it and are committed to achieving your complete satisfaction. Not only that, it is in Rodwell Engineering Group s best interest to keep your autoclave running reliably for as long as possible in order to maintain the reputation for reliability and durability that we currently enjoy. Genuine Parts Your autoclave is made up of hundreds of different parts, set up to various tolerances and finely set to give maximum performance and paramount safety. Whenever a worn part is replaced, you should make sure that genuine Rodwell Scientific Instruments parts are used. They are designed, tested and manufactured to the original tolerances and specification. Only Rodwell Engineering know exactly what is required of each part because it is only Rodwell Scientific Instruments who designed each part to come together perfectly to make the overall machine - your Rodwell Autoclave. Calibration Rodwell Scientific Instruments offer a calibration service using the very latest cycle recording equipment. This work can be carried out to the most demanding standards. The equipment and working practices equate or improve on any of those standards dictated by any accreditation authority and Rodwell Scientific Instruments have the knowledge and expertise to fine-tune your autoclave if deemed necessary. Expertise Rodwell and their approved service agents have highly trained technicians with the specialist skills and knowledge required to maintain your autoclave in accordance with Rodwell Scientific Instruments recommendations and leave your equipment in a SAFE STATE OF REPAIR. Our trained engineers have access to the latest technical information so they know precisely what s needed to maintain your autoclave in a safe and reliable condition. Specialist Equipment Every Rodwell Engineer has access to a vast array of specialised spare parts and tools essential to keep your autoclave in a reliable, safe state of repair. Consider this: an autoclave is a pressure vessel with a door that has a force equivalent to 3 to 11 tonnes exerted on it when up to pressure. Do you want to be responsible for any accidents or litigation as a result of your authorisation for maintenance by a company not trained or accredited by the manufacturer of the equipment? Please feel free to contact our technical service team with any questions regarding the maintenance of your autoclave, or queries about spare parts. +44 (0) [email protected] 11
12 Rodwell Scientific Instruments Bentalls Pipps Hill Industrial Estate Basildon Essex SS14 3SD United Kingdom Tel:+44 (0) Fax: +44 (0) Online: Rodwell Every effort has been made to ensure that the information in this brochure is correct at time of going to press. The services and products described in the brochure are subject to continuous development and improvement and Rodwell Scientific Instruments reserves the right to change these at anytime. Actual colours may vary. All trademarks acknowledged. E.&O.E All Rights Reserved - Rodwell Engineering Group Limited
Laboratory Line. Vertical and Bench-Top Life Science Autoclaves
Laboratory Line Vertical and Bench-Top Life Science Autoclaves The Advanced Laboratory Line The Full Spectrum of Laboratory Sterilizers Sterilization in a laboratory environment has its unique requirements.
Vertical and Benchtop Autoclaves for Life Sciences. Laboratory Line
Vertical and Benchtop Autoclaves for Life Sciences Laboratory Line Designed for Your Laboratory Applications Advanced Laboratory Autoclaves Tuttnauer laboratory autoclaves have been designed to provide
LABOKLAV. Autoclaves Made in Germany. www.shp-steriltechnik.de
LABOKLAV Autoclaves Made in Germany www.shp-steriltechnik.de 2 LABOKLAV STEAM STERILIZERS Steam sterilization is the sterilization method with the widest range of applications efficient, safe, reproducible
Partnership. Medical Waste Autoclaves. Medical Waste Autoclaves
Partnership Medical Waste Autoclaves Medical Waste Autoclaves Safe, Cost-Effective, Medical Waste Sterilization Keep your environment safe from Medical Waste with high performance Tuttnauer Medical Waste
Touchclave-Lab... the revolutionary new range of square-section laboratory sterilizers from LTE Scientific
Other Products and Services from LTE Scientific LTE Scientific Ltd. LTE Cylindrical Chamber Autoclaves 40 to 380 litres capacity LTE Touchclave Systems Autoclaves from 150 to 10,000 litres capacity Kill
OT 40L / 90L. Laboratory Steam Sterilizers
OT 40L / 90L Laboratory Steam Sterilizers OT 40L / 90L LABORATORY STEAM STERILIZERS OT 40L / OT 90L laboratory steam sterilizers are specially designed for the steam sterilization of liquid and culture
Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed
Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Rely on GD to provide the perfect fit The perfect fit to maximise productivity The growing industrial demand for compressed air requires
Horizontal Steam Sterilizers. Healthcare Line. Since
Horizontal Steam Sterilizers Healthcare Line Since 1925 Horizontal Steam Sterilizers for Healthcare Applications The Tuttnauer line of healthcare sterilizers are designed for hospital operating rooms,
Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications
Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications Part of Thermo Fisher Scientific Thermo Scientific Varioklav Laboratory
Laboratory & Scientific Line. Horizontal Steam Sterilizers
Laboratory & Scientific Line Horizontal Steam Sterilizers Horizontal Steam Sterilizers for Laboratory & Scientific Applications Sterilization in a laboratory environment has its unique requirements. The
Hospital Sterilizers. T-Max Line
Hospital Sterilizers T-Max Line Hospital Sterilizers Sterilization is a complex process. Like any complex process, many things can go wrong. A Hospital depends on its CSSD: Central Sterile Services Department.
Laboratory & Scientific Line. Bulk Steam Sterilizers. Since
Laboratory & Scientific Line Bulk Steam Sterilizers Since 1925 Bulk Steam Sterilizers for Laboratory & Scientific Applications The Tuttnauer line of bulk autoclaves are designed to handle the most critical
AUTOCLAVE STEAM STERILIZERS
AUTOCLAVE STEAM STERILIZERS (BENCH TOP) Image: HS-1606VD Hanshin Bench Top Steam Sterilizer Small and easy to operate Three preset sterilization cycles Adjustable cycle presets Rapid heat up times Option
Medical Waste Autoclaves. Medical Waste Autoclaves
Medical Waste Autoclaves Medical Waste Autoclaves Safe, Cost-Effective, Medical Waste Sterilization Treat Medical Waste with high performance Tuttnauer Medical Waste autoclave systems designed for small,
Large Steam Sterilizers for the Life Sciences. Laboratory Line
Large Steam Sterilizers for the Life Sciences Laboratory Line Large Steam Sterilizers for the Life Sciences Sterilization in a laboratory environment has its unique requirements. The types of loads that
Freezers - Ultrafreezers. Platilab & Irilab Series
Freezers - Ultrafreezers Platilab & Irilab Series PLATILAB: top security and performances with reliable temperature control. IRILAB: combining the high reliability of PLATILAB with the possibility to store
LTE Scientific Ltd. Touchclave-Lab... the revolutionary range of square-section laboratory sterilizers from LTE Scientific
LTE Scientific Ltd. Touchclave-Lab... the revolutionary range of square-section laboratory sterilizers from LTE Scientific About LTE Scientific Contents Touchclave-Lab the revolutionary range of sterilizers
Laboratory- and sterilisation equipment HMC EUROPE
Laboratory- and sterilisation equipment HMC EUROPE PROFILE HMC EUROPE Laboratory- and sterilisation equipment Consistent marketing of technologies and the conversion of new ideas create product ranges,
BSL3 and BSL4 Autoclaves. Laboratory Line
BSL3 and BSL4 Autoclaves Laboratory Line BSL3 and BSL4 Autoclaves In today s society the need for safe bio-containment systems is increasingly important. This is especially true in the sterilization process
Model Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/50 1100 1 Ø90x160mm W200xH385xD450 30 (Net:28)
Table Top STE-TEN STE-TEN, 1 Liter Autoclave It adopts B-wclass (pred-13060), with 3-times pre-vacuum preceding vacuum drying. Residual humidity is 0.2, vacuum measurement reaches -0.7bar. It sterilizes
German engineering under high pressure
German engineering under high pressure Over 25 years of experience as a manufacturer of sterilizers, autoclaves and lyophilization systems for laboratories, production and research Production-scale autoclaves
globe reactions made easy Process perfection
globe reactions made easy Process perfection Benefits More reactions in less time: The Globe oil drain unit and quick clamp allow single hand vessel changes in seconds Space saving: 50ml, 100ml, 250ml,
FVA/A1 saturated-steam sterilizer
FVA/A1 where technology innovation and design come together FVA/A1 saturated-steam sterilizer www.fedegariautoklaven.ch Fedegari's new FVA/A1 series of automatic vertical sterilizers has been expressly
LyoBeta. R+D Freeze-Dryers
LyoBeta R+D Freeze-Dryers LyoBeta series A Responsible Choice New demands in R+D centers are related to scale-up feasibility and quality of procedures and research methods. FDA investigators consider that
Tabletop Line. Automatic and Semi-Automatic Autoclave Series
Tabletop Line Automatic and Semi-Automatic Autoclave Series Tuttnauer Your Sterilization & Infection Control Partner Company Profile For over 80 years, Tuttnauer s sterilization and infection control products
Guidance on safe use of Autoclaves
Safety Office Reviewed: Dec 2013 Reviewed: DD Month Year Guidance on safe use of Autoclaves 1. Hazards & Uses There are several different types of hazard associated with the use of autoclaves. The main
Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance
Bench Autoclave Standard Operating Procedure For Installation, Use and Maintenance 1. Introduction This SOP is intended for use with the following model, in a laboratory context: Type: Nuve Bench Top Steam
Kompressoren. Adsorption Dryer AD
Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated
UNDERSTANDING HOT WATER SYSTEMS IN THE HOME
UNDERSTANDING HOT WATER SYSTEMS IN THE HOME This advice guide is part of a series of free guides produced by the Association of Plumbing & Heating Contractors Ltd. which provide consumers with essential
Electric Flow Boiler
Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler
Partnership. Large Steam Autoclaves for the Life Sciences. Laboratory Line
Partnership Large Steam Autoclaves for the Life Sciences Laboratory Line Large Steam Autoclaves for the Life Sciences Sterilization in a laboratory environment has its unique requirements. Tuttnauer laboratory
GUIDE TO AUTOCLAVING PIONEERS IN STERILIZATION TECHNOLOGY
GUIDE TO AUTOCLAVING PIONEERS IN STERILIZATION TECHNOLOGY What is Sterilization? Sterilization may be defined as the statistically complete destruction of all microorganisms including the most resistant
Visions become real. Temperature control and cooling systems. The innovative and reliable solution
Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature
STEAM STERILIZERS. DLOV & DLOM series. more than fifty years of experience in sterilization. DE LAMA s Quality Management System is certified:
STEAM STERILIZERS DLOV & DLOM series DE LAMA s Quality Management System is certified: more than fifty years of experience in sterilization UNI EN ISO 9001:2000 - Cert. n 0351 UNI EN ISO 13485 - Cert.
18 LITER VOLUME STERILISATION MATERIALS TESTING MEDIA PREPARATION
18 LITER VOLUME STERILISATION MATERIALS TESTING MEDIA PREPARATION Applications THE WIDE RANGE OF USING CERTOCLAV AUTOCLAVES MICROBIOLOGY / BIO-CHEMISTRY Autoclave culture mediums Refuse sterilisation Efficiently
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
Laboratory Autoclave SN210/310/510,SQ510/810
1/5 Laboratory Autoclave SN210/310/510,SQ510/810 SN210/310/510,SQ510/810 The highest temperature of 135deg.C Upwards opening lid SN210 SN310 SN510 Effective Capacity : 20LEffective Capacity : 32L Effective
FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS
The key difference between a small vertical or bench-top sterilizer and industrial sterilizer is performance. Small saturated-steam sterilizers with vertical or horizontal chambers were devised many years
CONTENTS. Swiftlock Compact Units 23-60 litres Including Benchtop and Top Loading Models. Pages 1-2
CONTENTS Swiftlock Compact Units 23-60 litres Including Benchtop and Top Loading Models Pages 1-2 Swiftlock Top Loading Units 90-130 litres For all standard laboratory applications Page 3 VACUUM Swiftlock
Vertical Display and Storage B1350-2. SKOPE Gen2: Three Door Chiller
Vertical Display and Storage User Manual MAN1227 Rev. 3.0 March 2008 edition CONTACT ADDRESSES Designed and Manufactured by New Zealand SKOPE INDUSTRIES LIMITED PO Box 1091, Christchurch New Zealand Freephone:
Laboratory- and sterilisation equipment HMC EUROPE
Laboratory- and sterilisation equipment HMC PROFILE HMC Laboratory- and sterilisation equipment Consistent marketing of technologies and the conversion of new ideas create product ranges, that are tailor-made
Cooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL
NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. Esenboğa Yolu 22 km Akyurt - ANKARA / TURKEY Tel : (00 90 312)
Sterilizers with extra class
Sterilizers with extra class ClassB Ready for the future The European standard EN 13060 specifies the performance requirements and test methods for small steam sterilizers. These are used for hygiene and
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
UNDERSTANDING CENTRAL HEATING SYSTEMS
UNDERSTANDING CENTRAL HEATING SYSTEMS This advice guide is part of a series of free guides produced by the Association of Plumbing & Heating Contractors Ltd. which provide consumers with essential basic
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS PARTS LIST Front Back FIG.5 FIG.6 1. Control panel 2. Carrying handle 3. Water tank 4. Casters
Laboratory Autoclaves
Laboratory Autoclaves 1 LTE Scientific Ltd is a leading designer and manufacturer of sterilizing autoclaves and other laboratory and medical processing equipment. From its UK base near Manchester, LTE
ORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
Model Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/50 1100 1 Ø90x160mm W200xH385xD450 30 (Net:28)
Table Top STE-TEN STE-TEN, 1 Liter Autoclave It adopts B-class (pred-13060), with 3-times pre-vacuum preceding vacuum drying. Residual humidity is 0.2, vacuum measurement reaches -0.7bar. It sterilizes
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
Use and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
Nirvana. Cycling Refrigerated Dryers
Nirvana Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Reliability Is Our Design Ingersoll Rand's Nirvana Cycling Refrigerated Dryer provides reliability like no other dryer in its class:
Blowdown vessels Meeting the requirements of HSE PM60
Blowdown vessels Meeting the requirements of HSE PM60 BDV60 blowdown vessels complete range of equipment for the safe disposal of boiler blowdown Boiler blowdown Steam boilers must be blown down to remove
PTAC Preventive Maintenance Guide. Step-by-step instructions and information to keep your units operating in peak condition
PTAC Preventive Maintenance Guide Step-by-step instructions and information to keep your units operating in peak condition The Importance of Proper PTAC Maintenance Welcome to the PTAC Preventive Maintenance
STERILIZERS, LABORATORY DRYING OVENS
TS9026 TS9053 TS9135 TS9430 TS 9000 SERIES: STERILIZERS, LABORATORY DRYING OVENS Series TS9000 consists of four different cabinets available in sizes from 26 litres to 430 litres. Interior housing and
Designed for multi-injector endurance testing, the
Designed for multi-injector endurance testing, the ETB Test Bench can optionally provide shot-to-shot mass measurement. The injectors are precisely subject to variable controls and hydraulic pressures
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
ThermoSorb Desiccant Dryers
ThermoSorb Desiccant Dryers Sierra Why dry compressed air? Contamination reduces efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. During the compression
AUTOCLAVES. Table Top. STE-TEN, 1 Liter Autoclave
Table Top STE-TEN, 1 Liter utoclave STE-TEN It adopts B-wclass (pred-13060), with 3-times pre-vacuum preceding vacuum drying. Residual humidity is 0.2, vacuum measurement reaches -0.7bar. It sterilizes
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
Heating Water by Direct Steam Injection
Heating Water by Direct Steam Injection Producing hot water by direct steam injection provides a solution where large volumes of hot water at precise temperatures are required, and where energy and space
Laminar Flow Cabinets and Workstations
VERTICAL AND HORIZONTAL HEPA FILTERED SYSTEMS FOR PROCESS OR OPERATOR PROTECTION Laminar Flow Cabinets and Workstations For procedures requiring protection from particulate contamination and for aseptic
EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption.
THE EXPRESS STILL This still represents the next generation in home distillation equipment. It eliminates the problem of having to spend all day processing a 25 litre wash. Taking 1 hour to heat up, then
techorganizer and techbench built for durability, designed for flexibility
techorganizer and techbench built for durability, designed for flexibility Wright Line sets a higher standard for engineering, manufacturing, test and assembly environments with TechBench and. TechBench,
Silicone oil is as the medium and the drying effect is uniform. The Temperature error is less than or equal 1.
Characteristic: The process of pre-freezing and drying finishes in situ. The freeze dryer is equipped with observation windows and the drying process is intuitive. Silicone oil is as the medium and the
GETINGE GEB SERIES BIOSAFETY STERILIZERS SAFE, RELIABLE DECONTAMINATION IN BIOCONTAINMENT FACILITIES. Always with you
GETINGE GEB SERIES BIOSAFETY STERILIZERS SAFE, RELIABLE DECONTAMINATION IN BIOCONTAINMENT FACILITIES Always with you 2 Getinge GEB Sterilizers LIGhTS ON FOR ThE NEw GENERATION STERILIZERS The new Getinge
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
www.bradyid.com Food Safety Starts with Workplace Safety Workplace Safety Products For Food and Beverage Processing Facilities
www.bradyid.com Food Safety Starts with Workplace Safety Workplace Safety Products For Food and Beverage Processing Facilities FOOD SAFETY: The foundation of a safe and profitable food processing plant
Benchmark. WASH l RINSE l PASSIVATE l DRY. Benchmark Precision Aqueous Cleaning Systems Modular Design, Superior Clean, Unwavering Service
Benchmark WASH l RINSE l PASSIVATE l DRY Benchmark Precision Aqueous Cleaning Systems Modular Design, Superior Clean, Unwavering Service The Standard By Which All Others Are Judged The Branson Benchmark
PBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
IC+ NEW inverter compressor technology delivers energy saving, high performance cooling
-3ºC Biomedical Freezers With Inverter Control KM-MU28H1E / KM-MU9H1E l NEW inverter compressor technology delivers energy saving, high performance cooling l Outstanding reliability and performance for
Gallagher Vapour Recovery Monitoring
Gallagher Vapour Recovery Monitoring VR Site Monitoring The status display enables site operators to comply with VR legislation. The laws and guidelines for the New South Wales Vapour Recovery regulations
SWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
Response: The combi boiler. Response: The fit anywhere combi
Response: The combi boiler The Ideal Response is a wall mounted, fanned flue combination boiler which serves a home's central heating system and delivers hot water on demand. It has been designed to be
EcoCWave. The all-round talent for aqueous part cleaning. www.durr.com
EcoCWave The all-round talent for aqueous part cleaning www.durr.com Part cleaning as a value-adding value-adding process process Increasing demands on cleanliness in component manufacturing impose a need
data sheet DONATELLO Rev. I emiss - 25/10/2013 52PRO03 code Automatic tissue processor DONATELLO
Rev. I emiss - /0/0 DONATELLO Automatic floor closed cycle processor for histological specimens Automatic tissue processor DONATELLO code PRO0 General characteristics DONATELLO is a closed cycle processor
ROTATING MACHINES. Alignment & Positioning of. Fast, easy and accurate alignment of rotating machines, pumps, drives, foundations, etc.
Alignment & Positioning of ROTATING MACHINES Fast, easy and accurate alignment of rotating machines, pumps, drives, foundations, etc. To compete in today s marketplace, you have to outperform your competitors
A SUPERIOR SOLUTION TO DRUM AND STEEL TANK USAGE
A SUPERIOR SOLUTION TO DRUM AND STEEL TANK USAGE The U.L.C. Listed C142.14-03 Cubet container provides a unique solution to storage and dispensing fluids. The Cubet s logical and integrated design allows
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
GenStore Archive Cabinet
GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 Two GenStore Archives shown mounted on optional table stand. 2 Contents Getting Started... 4 Using this Manual...4 Safety Precautions...4
Instruction Booklet. iket2702
Instruction Booklet iket2702 goodbye waiting hello ikettle Control your ikettle via your smartphone Use your smartphone or tablet with the ikettle. Easy one-touch set up Simple connectivity both quick
STANDARD OPERATING PROCEDURES Safe Autoclave Operations
Department of Environmental Health & Safety Biosafety & Biosecurity STANDARD OPERATING PROCEDURES Safe Autoclave Operations The purpose of this document is to provide standard operating procedures for
English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...
2 Contents Components Attachments Guidance Installation Operation Maintenance Service Technical Troubleshooting Symbols used to mark instructions...3 Included Attachments...4 Congratulations...5 Getting
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair
The Concept A Europe-wide research and development programme identified the need for a high performance cassette fan convector, powered by low pressure hot water and compatible with universal suspended
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Oil-Free Screw Compressors. Water-injected Technology. Rely on GD to provide the perfect fit
Oil-Free Screw Compressors Water-injected Technology Rely on GD to provide the perfect fit Why oil-free? Don t compromise on quality If 100% clean and oil-free compressed air is a requirement for your
Systec Laboratory Autoclaves Systec H-Series. Horizontal floor-standing autoclaves. Systec H-Series 2D. Pass-through autoclaves.
Fotolia Layout Systec Laboratory Autoclaves Systec H-Series. Horizontal floor-standing autoclaves. Systec H-Series 2D. Pass-through autoclaves. Performance and competence. Experience counts We focus on
Factory owners must ensure the boiler is:
Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised
Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators
Atlas Copco On-site Industrial Gases Nitrogen & Oxygen Generators A secure supply of nitrogen and oxygen Whether your company is specialized in chemical manufacturing, electronics, laser cutting or food
Mechanical Seal Piping Plans
Mechanical Seal Piping Plans Single Seals plans 01, 02, 03, 11, 13, 14, 21, 23, 31, 32, 41 Dual Seals plans 52, 53A, 53B, 53C, 54, 55 Quench Seals plans 62, 65A, 65B, 66A, 66B Gas Seals plans 72, 74, 75,
