Review of CD4 Technologies
|
|
|
- Hope Holmes
- 10 years ago
- Views:
Transcription
1 Review of CD4 Technologies Suzanne Crowe, Burnet Institute On behalf of Members of the CD4 Working Group, Forum for Collaborative HIV Research
2 Laboratory monitoring & the 3x5 program Cost of ARV Rx in developing countries is potentially exceeded by the cost of laboratory monitoring. Sophisticated assays often established as part of clinical trial infrastructure, paid for by international grants HIV+ individuals outside trials must find funds to pay for their own monitoring Monitoring HIV treatment is complex CD4 and VL Drug toxicity Adherence Drug resistance
3 New CD4 monitoring tests and technologies Flow based assays Guava EasyCD4 System Partec CyFlow PointCARE Panleukogating technology Manual assays Dynal immune bead-based assay (microscopy) Coulter immune bead-based assay (microscopy) In the pipeline LabNow microchip technology SemiBio slide test (microscopy) supar (soluble urokinase plasminogen activator receptor) CD4 dipstick for remote care
4 Dual Platform Flow Cytometry Slide courtesy of Roland Gohde
5 Single Platform Flow Cytometry Slide courtesy of Roland Gohde
6 Pan-leukogate or PLG CD4 Methodology Slides courtesy of Angela Vernon and Meryl Foreman, Beckman Coulter
7 PLG CD4 Methodology Ungated Identifies CD4+ lymphocytes based on a pan-leucocyte count WBC count (cells/ul) X CD4 events from region B CD45 events from region A = Absolute CD4 Gated on WBC The WBC gate is not affected by EDTA changes that occur with older specimens. Hematology lymph % is affected by EDTA, count not reliable beyond 24 hours. Slide courtesy of Angela Vernon and Meryl Foreman, Beckman Coulter
8 PLG CD4 Count (r 2 = 0.990) Glencross et al. Clinical Cytometry, 50:2, 2002
9 Aged Specimen Performance Limitations of Scatter Gating Forward Scatter cellular structure lost over time, results in inability to define appropriate gates using scatter alone WBC Gate Day 1 Lymphs CD4 T cells Day 5 Slides courtesy of Angela Vernon and Meryl Foreman, Beckman Coulter
10 PLG: Aged Specimen Performance Beijing, China CD4 Absolute Count n = 39 HIV+ volunteers Mean Specimens Linear (Mean) Days Mixed Model ANOVA for trend over time; p= CD4 Count Range: cells/μl; Median CD4 count = 371 cells/μl Slide courtesy of Ank Gowans, Beckman Coulter and CDC Beijing
11 Summary: PLG CD4 New flow cytometry-based method Based on a pan-leukocyte marker uses a 2-color pre-optimized reagent provides both CD4% and absolute counts extends sample age beyond 24 hrs to up to 5 days good correlation with gold standard flow compatible with most flow cytometers with 2 color capability & 488 nm laser line <$6 per test Licensed by Beckman Coulter from NHLS, South Africa High capacity: good for high volume centralized labs
12 Guava EasyCD4 Slides courtesy of Jeff Harvey, Tina Baumgartner, Leonard Buchner
13 Guava EasyCD4 Measures absolute CD4 (can measure CD8) Sample volume: 10 µl of whole blood (EDTA) Reagents 10 µl of antibody cocktail Anti-CD3-PE-Cy5 Anti-CD4-PE 180 µl of Lyse-Fix solution Components/Software Dell LapTop computer included Software includes instrument set-up, data acquisition and analysis
14 The Guava EasyCD4 System: Dell Laptop Windows 2000 Pentium IV EasyCD4 Software and Data Handling Capillary Flow Cell 21 cm Green Diode Laser Microliter Cell Samples 36 cm Waste Fluid 32 cm 15.9 kilos with PC
15 Guava EasyCD4 Protocol Add 10uL of antibody cocktail to each tube Add 10uL EDTA whole blood to each tube, vortex, incubate 15min Add 180uL of Lyse/Fix solution, incubate 15min During sample incubation, turn on power and allow 10 minute warm-up Run Guava Check QC procedure (5 min) Adjust (or recall) instrument settings Acquire samples; Analyze results
16
17 EasyCD4 vs MultitestCD Triplicates EasyCD4 TM R=0.97 R 2 = R1 R2 R3 Linear (x =y) Linear (R1) Linear (R2) Linear (R3) MultiTest TM CD4 UCSF-GCRC/GIVI-CFAR Core Immunology Laboratory
18 North America California 3 Site Trial 200 Residual Difference Site1 Site2 Site3 Mean +2SD -2SD N = Average Guava & BD MultiTest CD4 Slides courtesy of Jeff Harvey, Tina Baumgartner, Leonard Buchner
19 Guava EasyCD4 at YRG CARE
20 Summary Easy CD4 (Guava) Quick assay Reagent cost is low ($3/test) Capital costs high ($45,000) Existing QA panels not compatible with this technology Measures percentage CD4 as %CD3+ T cells Still undergoing evaluation
21 Partec Cy-Flow eg CyFlow Counter1P CyFlow SLGreen 2P CyFlow SL Blue 5P Slides courtesy of Roland Gohde
22 Cy-Flow no lyse - no wash CD4 protocol Step Protocol 50µl blood from the patient into a sample tube add 10µl of CD4-PE and incubate for 10 minutes at RT in the dark add 850µl of the no lyse dilution buffer
23 Slides courtesy of Roland Gohde
24 Cameroon: CD4 Counting - CyFlow vs. FACSCount 1500 r = CD4 count (FACSCount) CD4 count (CyFlow) Douala and Marua, Cameroon
25 Cameroon: CD4 - CyFlow vs. FACSCount Bland-Altman Plot difference between CyFlow and FACSCount (CD4/µl) bias 8 CD4/µl mean +2sd mean of difference (bias) zero bias mean -2sd mean of methods CyFlow and FACSCount (CD4/µl) Douala and Marua, Cameroon
26
27
28 Summary Partec Cyflow Simple and portable flow cytometric assay No formal comparisons with samples provided by external QA programs available at this time Reagent costs $2-3/test Capital costs approx $20,000 Absolute CD4 only
29 PointCARE Slides courtesy of Cecil Sherrer
30 PointCARE System %CD4 and Absolute CD4 WBC, LY% and count Mobile; battery backup Room temperature reagent storage and operation
31 Closed- tube operation biohazard containment via cap piercing 4. Lysing Reagent Tube or Cleaning Solution Tube 3. Rinse Tube 2. CD4 Reagent Tube 1. Patient Whole Blood Sample Tube Patient sample and reagents bar-code are tracked in the instrument. Ideal for low-volume, decentralized labs
32 Automated Patient Results Both CD4% & Absolute CD4 without beads critical for pediatrics Depending on test volume, cost of patient result is under US$10 Cost of patient result includes: All reagents and disposables Operator time CD4, CD4%, WBC, LY, LY% Service
33 PointCARE comparison with DP Flow CD4 Count- Method Comparison N = 68 PointCARE CD4 Counts y = x R = REF Dual Platform CD4 Counts CD4 Count- REF /uL Bias Plot N = 23 % Bias = (FC - REF) / REF REF Dual Platform CD4 Counts
34 Summary PointCARE Recently received FDA approval %CD4 (as percentage of CD3+T cells) Cost approximately $10/test Capital cost approx $15,000-20,000
35 Manual low cost assays for monitoring CD4 Vidal, Omah Mooleedhar, Shahir Ali, CAREC Data from Crowe lab, Burnet Institute Melb and Dr Balakrishnan s lab, YRG Care Chennai Arlene Darmanie, Cecile Goddard
36 CD4 manual methods Dynal assay CD14 Dynabeads Monocyte-depleted blood removed to new tube CD4 Dynabeads Lysis and staining of nuclei Count stained nuclei Coulter assay Monocyte blocking agent CD4 cytospheres Add blood to staining solution Count cells with beads attached Crowe, et al. CID 2003: 37 (suppl 1) S25-35
37 What equipment is needed for these manual CD4 assays? Microscope with 40x objective Hemocytometer 0.1 mm deep Manual counter Tubes Pipettes Plus rotating wheel and magnet for Dynal assay
38 Bland-Altman plot for difference against mean for CD4+ T-lymphocyte counts by flow cytometry and Coulter cyto-sphere assay 300 (n=122). 200 Difference Mean Balakrishnan Pachamuthu et al
39 Correlation of Flow SP and Dynal assay Dynal assay (cells/ul) R= 0.97, n= Flow cytometry (cells/ul) Dynal assay shows excellent association with flow cytometry Difference in CD4 count (cells/ul) Bland-Altman Plot n= Average CD4 count by Flow cytometry and Dynal assay (cells/ul) Average Flow cytometry result is 65 cells/µl higher than Dynal assay Crowe et al 2003
40 Comparison of CD4 Count between DYNAL and FACSCount (n=85) Series1 Mean Residual (Dynal-FACSCount) Average of Dynal IFA and FACSCount Mean + 2STD Mean - 2STD Arlene Darmanie, et al CAREC
41 Coefficient of variation Dynal assay vs flow cytometry in West Africa DYNABEADS R Sites Site 1 Site 2 Site 3 Ref site Site 4 Site 5 Site 6 All Sites CV n Flow Cytometry CV n Reference site Sites Distant from Reference site Diagbouga S et al AIDS 2004
42 Impact of the delay in sample handling on Dynabeads R Technique at room temperature samples exhibiting 20% decrease in CD4 cell counts Time n % (95% CI) Hour 4 0 / 28 0 (0, 12.3) Hour 8 3 / (2.3, 28.2) Hour 12 Hour 24 5 / / (6.1, 36.9) 50.0 (30.7, 69.4) Diagbouga S et al AIDS 2004
43 Blood stabilizers Slides courtesy of Viv Granger and Dave Barnett, NEQAS UK and data from Amanda Lindholm Streck Laboratories
44 Reagents for stabilizing blood samples Guidelines, CD4 + T cell analysis: must be done within 18 hrs haematology analysers: difficulty producing a differential after 24 hrs CytoChex TM (Streck laboratories) Member of family of non cross-linking fixatives Orig. designed to preserve WBCs in whole blood (1:1) Cyto-Chex BCT contains 57ul preservative/anticoagulant Samples stable 7 days at ambient temps NEQAS (UK) TransFix TM lasts >10days, (1:10), <25 0 C Transfix: allows transportation of fixed samples Both compatible with flow technology No data on stabilized blood and manual CD4 counts Turpen & Collins Amer Clin Lab :30; Barnett et al Cytometry :216 Jani et al J Imm M eth :145
45 Flow Cytometric Analysis Fresh Day 7
46 Preservation of Lymphocyte Subsets with TransFIX 80 % Lymphocytes Normal s Unfixed TRANSFix Specimens CD 3 CD 4 0 Day 1 Day 2 Day 3 Day 4 Day 6 CD 8 CD 16/56 CD 19 Time after collection
47 Stability of CD3/4+ TCells post addition of TransFIX Stability of CD3/4+ T Cells post addition of TransFIX CD3/4+ T Cell count (cells/ul) Days post addition of TransFIX CD4 <100 >100 but <300 >300 but <500 >500
48 In the pipeline LabNow Microchip, reader and digital camera Individual biochips Absolute CD4 Tentatively planned for availability late 2005 Semi-Bio manual slide technology Slide with an anticd4 coated chamber that traps CD4+ cells during incubation Count CD4+T cells after staining Remote point-of-care technology No technical skill required For estimation of CD4+ T cells Early stages of development
49 Microchip technology with a reader device and digital camera
50 Data/Slide from Bill Rodriguez
51 Which low-cost CD4 assay to introduce?
52 Depends on Number of samples per day Low throughput, manual may be most cost-effective High throughput, flow method most cost effective (and definitely more practical) Sophistication of lab Current methods require varying degree of technical skill Remote point of care methods under development Availability of technical support & equipment maintenance training A key issue for flow cytometers Remote area, opt for manual or ship samples or ensure local engineers/technicians trained Cost
53 Word of caution when considering cost Hidden costs (ie non-kit costs) greatly influence the final cost to a testing laboratory in a resourceconstrained country Labour (often less expensive) Disposables (if available often more expensive) Shipping costs Importation costs Infrastructure Repeat assay runs Instrument repair Pricing may be best negotiated at an international or country level with bulk procurement schemes Elbeik et al Expert Rev PharmacoEconomics Outcomes Res :
54 Where are we up to? All assays/methods continuing to undergo incountry analyses Rigorous independent evaluation, including clinical trial evaluation and independent statistical analysis, is absolutely essential Some technologies /assays recently licensed in USA (PLG, PointCARE) However all are still emerging technologies QA participation essential and establishing this should be part of the deal Countries should not purchase technologies that have not been inadequately validated
55 Final thanks to Forum for Collaborative Research Ben Cheng Houtan Movafagh Ben Collins Veronica Miller Alan Landay (Chair) All those who provided slides for this presentation, especially Rolande Gohde (Partec) Jeff Harvey, Tina Baumgarten, Leonard Buchner (Guava) Angela Vernon and Meryl Foreman, (Beckman Coulter) Ank Gowans, Beckman Coulter and CDC Beijing Dr. Debbie K. Glencross and the NHLS of South Africa Dr Balakrishnan, YRGCare, Chennai Douala and Marua, Cameroon Viv Granger and Dave Barnett, NEQAS UK Cecil Sherrer (PointCARE) Vicki Greengrass, Mandy Dunne, Megan Plate, Pauline Steele (Burnet Institute) Roche (SC support to attend CROI)
APPLICATION INFORMATION
DRAFT: Rev. D A-2045A APPLICATION INFORMATION Flow Cytometry 3-COLOR COMPENSATION Raquel Cabana,* Mark Cheetham, Jay Enten, Yong Song, Michael Thomas,* and Brendan S. Yee Beckman Coulter, Inc., Miami FL
WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS
FOR IN-VITRO DIAGNOSTIC USE INVITROGEN CAL-LYSE TM Lysing Solution WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS CAL-LYSE TM CATALOG No. GAS-010 250 tests 25 ml CATALOG No. GAS-010S-100
123count ebeads Catalog Number: 01-1234 Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.
Page 1 of 1 Catalog Number: 01-1234 Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use. Normal human peripheral blood was stained with Anti- Human CD45 PE (cat.
Standardization, Calibration and Quality Control
Standardization, Calibration and Quality Control Ian Storie Flow cytometry has become an essential tool in the research and clinical diagnostic laboratory. The range of available flow-based diagnostic
LOAD & GO and make flow cytometry simplicity itself. the full spectrum of Flow Cytometry
LOAD & GO and make flow cytometry simplicity itself the full spectrum of Flow Cytometry Introducing Aquios CL...the first true LOAD & GO flow cytometer What would it mean for your laboratory s productivity
Absolute counting using flow cytometry. Bright Count Microspheres
Absolute counting using flow cytometry Single-platform system for absolute counts I PRODUCT MANUAL [REF] IQP-391 [REF] IQP-392 s 50 tests s 100 tests [IVD] In Vitro Diagnostic medical device IQ Products
Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T
Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom Cat. Reference: STP-25T Reagent provided:: 25 Stepcount tubes for 25 test INTENDED USE. Immunostep
RPCI 004 v.002 Staining Procedure For all Directly Conjugated Reagents (Whole Blood Method)
Immune Tolerance Network RPCI 004 v.002 Staining Procedure For all Directly Conjugated Reagents (Whole Blood Method) Author: Paul Wallace, Director, RPCI Laboratory of Flow Cytometry Approved by: Paul
PROTOCOL. Immunostaining for Flow Cytometry. Background. Materials and equipment required.
PROTOCOL Immunostaining for Flow Cytometry 1850 Millrace Drive, Suite 3A Eugene, Oregon 97403 Rev.0 Background The combination of single cell analysis using flow cytometry and the specificity of antibody-based
No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer
APPLICATION NOTE Attune NxT Flow Cytometer No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer Introduction Standard methods for isolating and detecting leukocytes
BD Trucount Tubes IVD
02/2015 23-3483-07 IVD BD Trucount Tubes For determining absolute counts of leucocytes in blood 25 Tubes Catalog No. 340334 BD, BD Logo and all other trademarks are property of Becton, Dickinson and Company.
Immunophenotyping peripheral blood cells
IMMUNOPHENOTYPING Attune Accoustic Focusing Cytometer Immunophenotyping peripheral blood cells A no-lyse, no-wash, no cell loss method for immunophenotyping nucleated peripheral blood cells using the Attune
BD FACSComp Software Tutorial
BD FACSComp Software Tutorial This tutorial guides you through a BD FACSComp software lyse/no-wash assay setup run. If you are already familiar with previous versions of BD FACSComp software on Mac OS
The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee
January, 1999 From: To: Subject: The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee NIAID DAIDS Flow Cytometry Laboratories Comparison study information for labs wishing to switch
Whole Blood Flow Cytometry
Whole Blood Flow Cytometry y Nailin Li Department t of Medicine, i Clinical i l Pharmacology Unit Karolinska Institute/University Hospital, 171 76 Stockholm Department of Pathology & Pathophysiology Zhejiang
Minimal residual disease detection in Acute Myeloid Leukaemia on a Becton Dickinson flow cytometer
Minimal residual disease detection in Acute Myeloid Leukaemia on a Becton Dickinson flow cytometer Purpose This procedure gives instruction on minimal residual disease (MRD) detection in patients with
CyFlow SL. Healthcare Immunology. Portable FCM System for 3-colour Immunophenotyping
CyFlow SL Healthcare Immunology Portable FCM System for 3-colour Immunophenotyping 01 COMPANY Flow Cytometry made in Germany New sophisticated applications and increasing requirements for reliable results
Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma
Mouse Insulin ELISA For the quantitative determination of insulin in mouse serum and plasma Please read carefully due to Critical Changes, e.g., Calculation of Results. For Research Use Only. Not For Use
Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement
Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement Andreas Spittler, MD, Associate Professor for Pathophysiology, Medical University
Standard Operating Procedure
1.0 Purpose: 1.1 The characterisation of of main leukocyte subsets in peripheral blood cells from mice by flow cytometry. Reliable values of frequencies of leukocyte clusters are very much dependent on
Notes on titering antibodies
Home Events This Week Bulletin Boards Lab Personnel Lab Policies Protocols MolBio Tetramers Proteins Flow Cytometry Immunoassays Instruments Computers Lab Publications Scientiific Literature Science on
MLX BCG Buccal Cell Genomic DNA Extraction Kit. Performance Characteristics
MLX BCG Buccal Cell Genomic DNA Extraction Kit Performance Characteristics Monolythix, Inc. 4720 Calle Carga Camarillo, CA 93012 Tel: (805) 484-8478 monolythix.com Page 2 of 9 MLX BCG Buccal Cell Genomic
Spherotech, Inc. 27845 Irma Lee Circle, Unit 101, Lake Forest, Illinois 60045 1
78 Irma Lee Circle, Unit 0, Lake Forest, Illinois 00 SPHERO TM Technical Note STN- Rev B 008 DETERMINING PMT LINEARITY IN FLOW CYTOMETERS USING THE SPHERO TM PMT QUALITY CONTROL EXCEL TEMPLATE Introduction
MANUAL PLATELET COUNT
MANUAL PLATELET COUNT Principle Whole blood is diluted with a 1% ammonium oxalate solution. The isotonic balance of the diluent is such that all erythrocytes are lysed while the leukocytes, platelets,
ab139418 Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis
ab139418 Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis Instructions for Use To determine cell cycle status in tissue culture cell lines by measuring DNA content using a flow cytometer. This
Point of Care HIV Viral Load Testing:
Point of Care HIV Viral Load Testing: Lesley Scott, Natasha Gous, Shuqi Chen *, Wendy Stevens Department of Molecular Medicine and Haematology University of the Witwatersrand, National Health Laboratory
Western Blot Protocol Protein isolation
Western Blot Protocol Protein isolation A. Preparation of cell lysates. - Preparation of materials: -Dial the microcentrifuge temperature control setting to 4 C -Prepare a bucket of ice -Prepare lysis
ab185915 Protein Sumoylation Assay Ultra Kit
ab185915 Protein Sumoylation Assay Ultra Kit Instructions for Use For the measuring in vivo protein sumoylation in various samples This product is for research use only and is not intended for diagnostic
IgE (Human) ELISA Kit
IgE (Human) ELISA Kit Catalog Number KA0216 96 assays Version: 03 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Background... 3 Principle of the Assay...
Cytell Cell Imaging System
Cytell Cell Imaging System Simplify your cell analysis and start changing tomorrow today www.gelifesciences.com/cytell The Cytell Cell Imaging System is an intuitive cell analysis instrument that streamlines
Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA
KAMIYA BIOMEDICAL COMPANY Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA For the quantitative determination of mouse CKMB in serum, plasma, cell culture fluid and other biological fluids Cat. No. KT-57681
use. 3,5 Apoptosis Viability Titration Assays
Introduction Monitoring cell viability can provide critical insights into the effectiveness of biological protocols and the stability of biological systems including: the efficacy of cell harvesting procedures,
Immunoglobulin E (IgE) concentrations in Human. Immunoglobulin E (IgE) Human ELISA Kit
ab108650 Immunoglobulin E (IgE) Human ELISA Kit Instructions for Use For the quantitative measurement of Immunoglobulin E (IgE) concentrations in Human serum. This product is for research use only and
Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility
Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility The mention of commercial products, their sources, or their use in connection
Analyzing Samples for CD34 Enumeration Using the BD Stem Cell Enumeration Kit
2 Analyzing Samples for CD34 Enumeration Using the BD Stem Cell Enumeration Kit Presented by Ellen Meinelt, MS MLS(ASCP) CM, Technical Applications Specialist and Calin Yuan, Product Course Developer,
Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking
Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking Mark KuKuruga Senior Technical Applications Specialist BD Biosciences 23-14462-00 Outline
for patient monitoring
Thermo Scientific Indiko Reagents for Immunosuppressant Drug Testing Complete solutions for patient monitoring The cost-effective Thermo Scientific Indiko benchtop analyzer and bar-coded reagent is designed
Flow cytometric analysis of stem cells derived from umbilical cord blood CD34+/CD45+ enumeration and viability
Flow cytometric analysis of stem cells derived from umbilical cord blood CD34+/CD45+ enumeration and viability Doretha Thompson Dissertation in fulfillment of the requirements for the degree Magister Scientiae
SmartFlare RNA Detection Probes: Principles, protocols and troubleshooting
Technical Guide SmartFlare RNA Detection Probes: Principles, protocols and troubleshooting Principles of SmartFlare technology RNA detection traditionally requires transfection, laborious sample prep,
Human Free Testosterone(F-TESTO) ELISA Kit
Human Free Testosterone(F-TESTO) ELISA Kit Catalog Number. MBS700040 For the quantitative determination of human free testosterone(f-testo) concentrations in serum, plasma. This package insert must be
Enhance Sensitivity of FISH Analysis with Highly Purified Multiple Myeloma Cells Using RoboSep, the Fully Automated Cell Separator
Enhance Sensitivity of FISH Analysis with Highly Purified Multiple Myeloma Cells Using RoboSep, the Fully Automated Cell Separator Benoit Guilbault, PhD Field Applications Scientist t STEMCELL Technologies,
Introduction to Flow Cytometry
Introduction to Flow Cytometry presented by: Flow Cytometry y Core Facility Biomedical Instrumentation Center Uniformed Services University Topics Covered in this Lecture What is flow cytometry? Flow cytometer
Preparation of Blood Films
Preparation of Blood Films Principle: Blood film enables us to evaluate WBC, RBC, and PLT morphology, also, allows us to perform differential WBC count, furthermore estimation of WBC and platelets counts
Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and
Using BD FACSDiva CST To Evaluate Cytometer Performance, Create Custom Assay Settings and Implement Cross-Instrument and Cross-Site Standardization of Assays PART 2 Alan M. Stall Director, Advanced Cytometry
Boundary-breaking acoustic focusing cytometry
Boundary-breaking acoustic focusing cytometry Introducing the Attune NxT Acoustic Focusing Cytometer a high-performance system that s flexible enough for any lab One of the main projects in my laboratory
Protein extraction from Tissues and Cultured Cells using Bioruptor Standard & Plus
Protein extraction from Tissues and Cultured Cells using Bioruptor Standard & Plus Introduction Protein extraction from tissues and cultured cells is the first step for many biochemical and analytical
QuantiFERON TB Gold In Tube Method (QGIT Test) Manufacturer: Cellestis Inc. (USA) a QIAGEN Company
QuantiFERON TB Gold In Tube Method (QGIT Test) Manufacturer: Cellestis Inc. (USA) a QIAGEN Company P1078 TB APPRISE TB Ante vs. Postpartum Prevention with INH in HIV Seropositive mothers and their Exposed
Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit
Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit Catalog No. CSB-E15852c (96T) This immunoassay kit allows for the in vitro quantitative determination of canine CK-MB concentrations in serum and plasma.
Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #: 3460-07
Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #: 3460-07 TABLE OF CONTENTS GENERAL INFORMATION... 2 Product Description... 2 Procedure Overview... 2 Kit Contents, Storage and Shelf Life... 3
BY UV SPECTROPHOTOMETRY
1 of 9 1. PURPOSE This Standard Operating Procedure describes the method for measuring the concentration of viral particles using UV/Vis spectrophotometry at 260 and 280 nm. 2. SCOPE This procedure is
How To Use An Enzymatics Spark Dna Sample Prep Kit For Ion Torrent
SPARK DNA Sample Prep Kit Ion Torrent (SPK0002-V08) Frequently Asked Questions Under what circumstances would I use SPARK DNA Sample Prep Kit for Ion Torrent? Enzymatics SPARK DNA Sample Prep Kit for Ion
Annexin V-EGFP Apoptosis Detection Kit
ab14153 Annexin V-EGFP Apoptosis Detection Kit Instructions for Use For the rapid, sensitive and accurate measurement of apoptosis in various samples This product is for research use only and is not intended
Molecular Assessment of Dried Blood Spot Quality during Development of a Novel Automated. Screening
Molecular Assessment of Dried Blood Spot Quality during Development of a Novel Automated in situ TREC qpcr Assay for SCID Screening J Bai, T Henry, J Benfer, S Berberich, T Kreman, and L DesJardin State
Laboratory Procedure Manual
Laboratory Procedure Manual Analyte: Matrix: Method: CD4+ T-Lymphocytes and CD8 T Cells Whole Blood TriCount Method Method No.: Revised: as performed by: Lee Lam or Marjorie Hubbard HIV Immunology and
Cell Sorting. S3e Cell Sorter Quick Guide
Cell Sorting S3e Cell Sorter Quick Guide STARTUP Checking Fluidics STARTUP There are three bulk fluid containers (Figure 1) that may require attention before starting the system. If fluidics need to be
Mobile Lab-Diagnostik
Mobile Lab-Diagnostik Jenaer Technologietag 2013 Alere Technologies GmbH, Jena; 11.11.2013, Torsten Schulz ALERE TECHNOLOGIES Alere Technologies GmbH former CLONDIAG GmbH 1998/1999 Foundation; 2001 first
BD FACSCalibur. The flow cytometer for your routine cell analysis needs
BD FACSCalibur The flow cytometer for your routine cell analysis needs A system with a rich application basis and a modular approach that continues to meet evolving needs of cell analysis worldwide. The
ABSTRACT INTRODUCTION
Performance of the PAXgene Blood DNA Tube for the Collection, Transport, and Storage of Whole Blood and the Purification of DNA Using the QIAsymphony Instrument L. Rainen 1, K. Guenther 2, E. Provencher
Human Luteinizing Hormone (LH) Custom Kit
Human Luteinizing Hormone (LH) Custom Kit 18089-v2-2015Jan 1 MSD Toxicology Assays Human Luteinizing Hormone (LH) Custom Kit This package insert must be read in its entirety before using this product.
Welcome to the fully integrated autoimmune laboratory. Saves time by reducing hands-on functions NOVA Lite Barcoded IFA Slides
The Integrated Lab Connected Welcome to the fully integrated autoimmune laboratory. Saves time by reducing hands-on functions NOVA Lite Barcoded IFA Slides NOVA View Reduces costs with automation efficiencies
Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer
Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer Presented by Clare Rogers, MS Senior Marketing Applications Specialist BD Biosciences 23-13660-00 Webinar Overview Multicolor
Introduction to Flow Cytometry
Outline Introduction to Flow Cytometry Basic Concept of Flow Cytometry Introduction to Instrument Subsystems Daisy Kuo Assistant Product Manager E-mail: [email protected] BDBiosciences Application Examples
Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit
Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit Catalog No: E0479r 96 Tests Operating instructions www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH
Becton-Dickinson FACSCalibur Flow Cytometer Instructions
Start-up 1. Turn on flow cytometer by pushing green button on right side of instrument, toward the back. Give it 30 minutes to warm up before collecting data. 2. Turn on monitor. 3. Turn on computer. If
Epinephrine/Norepinephrine ELISA Kit
Epinephrine/Norepinephrine ELISA Kit Catalog Number KA3767 96 assays Version: 01 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Principle of the Assay...
Islet Viability Assessment by Single Cell Flow Cytometry
Islet Viability Assessment by Single Cell Flow Cytometry Page 1 of 8 Purpose: To comprehensively assess the viability of the islet cell preparation prior to transplantation. Tissue Samples: A sample containing
Corporate Medical Policy
Corporate Medical Policy File Name: Origination: Last CAP Review: Next CAP Review: Last Review: immune_cell_function_assay 11/2009 3/2016 3/2017 3/2016 Description of Procedure or Service Careful monitoring
FOR REFERENCE PURPOSES
BIOO LIFE SCIENCE PRODUCTS FOR REFERENCE PURPOSES This manual is for Reference Purposes Only. DO NOT use this protocol to run your assays. Periodically, optimizations and revisions are made to the kit
Science is hard. Flow cytometry should be easy.
Science is hard. Flow cytometry should be easy. TABLE OF CONTENTS 1 INTRODUCTION TO BD ACCURI C6 SOFTWARE... 1 1.1 Starting BD Accuri C6 Software... 1 1.2 BD Accuri C6 Software Workspace... 2 1.3 Opening
Canine Creatine Kinase MM isoenzyme(ck-mm) ELISA. kit
BlueGene Biotech. Tel: 0086-21-61471242 Fax: 0086-21-61471242 ext 806 E-mail: [email protected] [email protected] www.elisakit.cc www.bluegene.cc Canine Creatine Kinase MM isoenzyme(ck-mm) ELISA kit 96
FULLY AUTOMATED AND VALIDATED HIGH VOLUME DNA EXTRACTION USING CHEMAGEN MAGNETIC BEADS BASED KITS
FULLY AUTOMATED AND VALIDATED HIGH VOLUME DNA EXTRACTION USING CHEMAGEN MAGNETIC BEADS BASED KITS Tom Janssens & Ivo Salden UZ Gasthuisberg, Center for Human Genetics, Leuven Perkin Elmer Webinar 27th
STANDARD OPERATING PROCEDURE
Title: Lymphocyte Proliferation Assay (LPA) Using 3 H- Thymidine Incorporation Assay Core Name: Lloyd Mayer, Mount Sinai Medical Center Effective Date: 02/16/2012 Trial Number: ITN047AI SOP # ITN2800 SOP
FCAP Array v3.0 Software: A New Tool to Analyze BD Cytometric Bead Array (CBA) Data. Monisha Sundarrajan, PhD BD Biosciences
FCAP Array v3.0 Software: A New Tool to Analyze BD Cytometric Bead Array (CBA) Data Monisha Sundarrajan, PhD BD Biosciences 23 13795 00 Agenda Introduction Overview of BD CBA bead based immunoassays FCAP
Instructions for Use. CyAn ADP. High-speed Analyzer. Summit 4.3. 0000050G June 2008. Beckman Coulter, Inc. 4300 N. Harbor Blvd. Fullerton, CA 92835
Instructions for Use CyAn ADP High-speed Analyzer Summit 4.3 0000050G June 2008 Beckman Coulter, Inc. 4300 N. Harbor Blvd. Fullerton, CA 92835 Overview Summit software is a Windows based application that
Human Peripheral Blood Mononuclear Cell (PBMC) Manual
Human Peripheral Blood Mononuclear Cell (PBMC) Manual INSTRUCTION MANUAL ZBM0063.04 SHIPPING CONDITIONS Human Peripheral Blood Mononuclear Cells, cryopreserved Cryopreserved human peripheral blood mononuclear
Application Note 10. Measurement of Cell Recovery. After Sorting with a Catcher-Tube-Based. Cell Sorter. Introduction
Application Note 10 Measurement of Cell Recovery After Sorting with a Catcher-Tube-Based Cell Sorter Introduction In many experiments using sorted cells, it is important to be able to count the number
Institut für Experimentelle Immunologie und Bildgebung
Page 1 von 6 Starting Up the System Start up the computer, start Windows and log in as IMCES_user start BD FACSDiva software with your Groupname Turn on the cytometer main power Wait a moment and Check
International Beryllium Conference, Montreal, Canada March 10, 2005
Alternative Lymphocyte Proliferation Tests: BrdU and Flow Cytometry Based Tests International Beryllium Conference, Montreal, Canada March 10, 2005 Tim K. Takaro Department of Environmental and Occupational
Malachite Green Phosphate Assay Kit
Malachite Green Phosphate Kit Item No. 10009325 Customer Service 800.364.9897 * Technical Support 888.526.5351 www.caymanchem.com TABLE OF CONTENTS GENERAL INFORMATION 3 Materials Supplied 4 Precautions
EdU Flow Cytometry Kit. User Manual
User Manual Ordering information: (for detailed kit content see Table 2) EdU Flow Cytometry Kits for 50 assays: Product number EdU Used fluorescent dye BCK-FC488-50 10 mg 6-FAM Azide BCK-FC555-50 10 mg
Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit
Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit Catalog Number. CSB-E14405r For the quantitative determination of rat creatine kinase MM isoenzyme (CK-MM) concentrations in serum, plasma and tissue
CyFlow SL. Microbiology. Detection and Analysis of Microorganisms and Small Particles
CyFlow SL Microbiology Detection and Analysis of Microorganisms and Small Particles 01 COMPANY Flow Cytometry made in Germany New sophisticated applications and increasing requirements for reliable results
Annexin V-FITC Apoptosis Detection Kit
ab14085 Annexin V-FITC Apoptosis Detection Kit Instructions for Use For the rapid, sensitive and accurate measurement of Apoptosis in living cells (adherent and suspension). This product is for research
Pentra DX Nexus. Process efficiency in Hematology
Pentra DX Nexus Process efficiency in Hematology Pentra DX Nexus Be productive and flexible 120 samples per hour 28 parameters Automatic reflex testing Automatic validation of results Integrated cytology
LABORATORY 2 Staining and processing of blood parasites Differential counts of leukocytes (giemsa stains)
LABORATORY 2 Staining and processing of blood parasites Differential counts of leukocytes (giemsa stains) SPECIMENS TO BE STAINED 1. Thin and thick blood smears from a patient returning from Africa - case
Lab 02: Blood Cytology (20 points)
Pierce College Putman/Biol 242 Name: Lab 02: Blood Cytology (20 points) Reference: Marieb & Mitchell 9 th Ed: 29A (Activities 1, 2, 3, 4, 7); 10 th Ed: Exercise 29 (Activities 1, 2, 3, 4, 7). Pierce College
CHAPTER 13. Quality Control/Quality Assurance
CHAPTER 13 Quality Control/Quality Assurance Quality Control/Quality Assurance (QC/QA) can be defined as the set of planned and systematic activities focused on providing confidence that quality requirements
Introduction to flow cytometry
Introduction to flow cytometry Flow cytometry is a popular laser-based technology. Discover more with our introduction to flow cytometry. Flow cytometry is now a widely used method for analyzing the expression
INSTRUCTION Probemaker
INSTRUCTION Probemaker Instructions for Duolink In Situ Probemaker PLUS (Art. no. 92009-0020) and Duolink In Situ Probemaker MINUS (Art. no. 92010-0020) Table of content 1. Introduction 4 2. Applications
STAINING OF PBF AND INTERPRETATION OF NORMAL AND ABNORMAL RED CELL MORPHOLOGY
9 STAINING OF PBF AND INTERPRETATION OF NORMAL AND ABNORMAL RED CELL MORPHOLOGY 9.1 INTRODUCTION A peripheral blood smear (peripheral blood film) is a glass microscope slide coated on one side with a thin
Expression of CD163 on Bovine Alveolar Macrophages and Peripheral Blood Mononuclear Cells
Expression of CD163 on Bovine Alveolar Macrophages and Peripheral Blood Mononuclear Cells Mary E. Kopechek Honor s Research Thesis May 17, 2007 Research Advisor: Dr. Jeff Lakritz, DVM, PhD The Ohio State
CFSE Cell Division Assay Kit
CFSE Cell Division Assay Kit Item No. 10009853 Customer Service 800.364.9897 * Technical Support 888.526.5351 www.caymanchem.com TABLE OF CONTENTS GENERAL INFORMATION 3 Materials Supplied 4 Precautions
MANUAL PLATELET COUNT
MANUAL PLATELET COUNT LAB OBJECTIVE The student will be able to perform, within K20% accuracy as compared to the automated result, five manual platelet counts using the Unopette system. and the light microscope.