GEN Series with Diesel Engine Pumps
|
|
|
- Evelyn Stafford
- 10 years ago
- Views:
Transcription
1 Hz GEN Series with Diesel Engine Pumps FIRE-FIGHTING BOOSTER SETS EN 1284, HIGH EFFICIENCY ELECTRIC PUMPS FHF and SHF SERIES WITH HIGH EFFICIENCY MOTORS AND DIESEL ENGINE PUMPS Cod Rev ev.a.a Ed.11/211
2 2
3 CONTENTS General introduction... 1 Characteristics of electric pumps diesel engine pumps Accessories and main components Choice and selection GEN..D/FHF series Range Hydraulic performance tables Electrical performace tables...3 DFHF series... 9 GEN..D/FHF series GEN..1D/FHF series GEN..1D/FHF series GEN..11D/FHF series Hc pressure drop curve in suction kit
4 CONTENTS 91 GEN..D/SHF series Range Hydraulic performance tables Electrical performance tables DSHF series GEN..D/SHF series GEN..1D/SHF series GEN..1D/SHF series GEN..11D/SHF series Hc pressure drop curve in suction kit Accessories Product description by technical specifications
5 GEN SERIES OF BOOSTER SETS GENERAL INTRODUCTION PRODUCT DESCRIPTION The GEN booster sets are built in conformity with EN1284 for automatic sprinkler systems and with UNI1779 for hydrant systems. In accordance with the above standards, all the main components of the booster set are factory connected and assembled. The configuration of the booster set depends on the number of pumps installed and on the type of electric motor or diesel engine, consistently with the type of supply chosen for the fire-fighting system from among those described in the standard. The water supply can be single, superior, duplicated or combined. Two main service pumps, one backing up the other, are normally installed for fire-fighting systems. The choice of electric motors or diesel engines depends on the level of reliability required from the system. In practice, fire-fighting booster sets have one electric service pump and one diesel service pump. Point 1.2 of EN 1284 states that for superior or duplicate water supplies, and if more than one pump is installed, no more than one service pump can be driven by the electric motor. This concept means that mixed assemblies, comprising electric or diesel pumps, have to be installed. This does not mean that it is not possible to have two electric pumps, one backing up the other, if the ascertained fire risk is low (single supplies) or if a diesel generator is already incorporated in the system. INTRODUCTION The Lowara GEN series of booster sets are therefore configured according to system requirements and initial considerations. They are also factory tested and comprise the following: One or two horizontal or vertical service pumps with the same hydraulic performance level, driven by an electric motor. Two horizontal service pumps with the same hydraulic performance level, driven by an electric motor and a diesel engine. A horizontal service pump driven by a diesel engine. The booster set is built and completed with the following main components: A Lowara SV series jockey electric pump (if required), controlled by an electric panel in the automatic mode. The jockey pump is automatically started and stopped by its pressure switch in order to restore supply pressure. This prevents the service pumps from starting and activating the main alarms. A control panel for each service pump. Two pressure switches for each service pump (if the first fails, the second repeats permission for the pump to start). On the discharge side of each service pump there is a on-off valve, a check valve and a tap for connection to the priming circuit for suction lift installations. Moreover, if the service pump works with a closed discharge line, a water recirculation tap has been applied to the pump body in order to prevent the pump from overheating. Discharge manifold connected to each service pump, fitted with a weld-on flange for connection to the system. Single base containing all the booster set components within a compact structure and ready for installation. To complete the pump station as requested by the standard, the GEN series of booster sets are fitted with the following accessories: Suction side kit. Flow meter. Alarm panel. Set of spare parts for diesel engines. Priming tank with accessories (for suction lift installations). 24L diaphragm tanks.
6 SET IDENTIFICATION TION CODE DIESEL ENGINE PUMP D FHF E A X / 32-2/D24 / B / IP INTRODUCTION Options: IP = Panels with IP protection. _ = Language group IT, EN, FI, PT. B = Language group EN, FR, DE, NL. Pump model. X = Automatic shut-off. A = Version with periodic self-test. EN 1284 Fire-fighting series. FHF = Pump code. SHF = Pump code. Diesel engine pump. DIESEL ENGINE PUMP SET GEN A X D / FHF 32-2/D24 / B / IP Options: IP = Panels with IP protection. _ = Language group IT, EN, FI, PT. B = Language group EN, FR, DE, NL. FHF = Pump code. SHF = Pump code. Diesel engine pump only. X = Automatic shut-off. A = Version with periodic self-test. GEN Fire-fighting series. RU SET WITH DIESEL ENGINE PUMP AND ELECTRIC PUMP GEN Y B X 1 1 D / FHF 32-2/4/D24 + 1SV1 / B / IP Options: CP = Clean contacts in electric pump panel. IP = Panels with IP protection. KV = Voltmeter kit. _ = Language group IT, EN, FI, PT. B = Language group EN, FR, DE, NL. Jockey pump code. FHF = Service pump code. SHF = Service pump code. D = With diesel engine pump. = Without electric jockey pump. 1 = With electric jockey pump. = Without electric service pump. 1 = With 1 electric service pump. X = Automatic shut-off. B = Basic version (only mark if electric service pump is present). A = Version with periodic self-test. Electric service pump electric start-up D = Direct start (Up to and including 22 kw). Y = Star/delta start. I = Impedance start. GEN Fire-fighting series. 6
7 REFERENCE STANDARDS The Lowara fire-fighting booster sets are EC certified in conformity with the following directives: - Machine Directive 26/42/EC. - Low Voltage Directive 26/9/EC. - Electromagnetic Compatibility Directive 24/18/EC. The electric pump performance is declared to be in accordance with the following standard: ISO 996-A Rotodynamic pumps hydraulic performance tests and acceptation criteria. The fire-fighting booster sets conform to the European fire-fighting Standard EN The automatic shut-off versions also conform to the UNI 1779 Italian Standard for hydrant systems. INTRODUCTION 7
8 P P GEN SERIES OF BOOSTER SETS FUNCTIONAL DIAGRAM FOR POSITIVE SUCTION HEAD INSTALLA ALLATIONS P P P P PRESSURE GAUGE MEMBRANE VESSEL M DRIVE UNIT LEVEL SWITCH INTRODUCTION FIRE FIGHTING SYSTEM PM P MQ PM FIRE FIGHTING SYSTEM PM MQ PUMP PRESSURE SWITCH STARTING OPEN DRAINAGE FLOW METER STRAINER FLOATING TAP PUMP RUNNING PRESSURE SWITCH CONNECTIONS ON-OFF VALVE NON RETURN VALVE RUBBER JOINT QF, CONTROL PANEL FOR DUTY ELECTRIC PUMP QF, CONTROL PANEL FOR DUTY DIESEL PUMP QPD, CONTROL PANEL FOR JOCKEY PUMP QAL, ALARMS CONTROL PANEL ECCENTRIC REDUCER WATER SUPPLY M M M WATER SUPPLY HYDRAULIC PIPING LINE POWER SUPPLY ELEMENTS ON REQUEST INSTALLATION BY CUSTOMER NOTE: ONLY APPROXIMATE DRAWING QF QPD QMTP QAL POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY 1284-GEN11D_SPB-EN_B_SC GEN SERIES OF BOOSTER SETS FUNCTIONAL DIAGRAM FOR SUCTION LIFT INSTALLA ALLATIONS PRESSURE GAUGE MEMBRANE VESSEL P P P P M DRIVE UNIT LEVEL SWITCH PUMP ON-OFF VALVE PRESSURE SWITCH STARTING NON RETURN VALVE FIRE FIGHTING SYSTEM MQ FIRE FIGHTING SYSTEM OPEN DRAINAGE RUBBER JOINT MQ FLOW METER STRAINER QF, CONTROL PANEL FOR DUTY ELECTRIC PUMP QF, CONTROL PANEL FOR DUTY DIESEL PUMP QPD, CONTROL PANEL FOR JOCKEY PUMP QAL, ALARMS CONTROL PANEL FLOATING TAP ECCENTRIC REDUCER PM PUMP RUNNING PRESSURE SWITCH P WATER TANK SUPPLY PM CONNECTIONS PM M M M HYDRAULIC PIPING LINE POWER SUPPLY ELEMENTS ON REQUEST INSTALLATION BY CUSTOMER NOTE: ONLY APPROXIMATE DRAWING QF QPD QMTP QAL POWER SUPPLY POWER SUPPLY POWER SUPPLY POWER SUPPLY 1284-GEN11D_STB-EN_B_SC 8
9 GEN SERIES OF BOOSTER SETS MECHANICAL CONFIGURATION INTRODUCTION DENOMINAZIONE COMPONENTI GRUPPI DIESEL EN1284 REF. DESCRIPTION REF. DESCRIPTION 1 electric service pump 1 divergent on discharge line 2 diesel engine service pump 11 inspectable check valve 3 jockey pump discharge line 12 on-off valve on discharge line 4 control panels 13 pressure gauge pump suction line 14 discharge manifold 6* on-off valve on suction line 1 service pump starter (2x) 7 eccentric divergent 16 diaphragm tanks 8 vacuum pressure gauge 17 priming circuit tap 9 anti-vibration joint 18 recirculation circuit tap * Optional in case of positive suction head installation. gen11d-comp-en_b_tp 9
10 CHARACTERISTICS S OF THE PUMPS USED IN THE GEN SERIES OF BOOSTER SETS INTRODUCTION 1SV ELECTRIC PUMPS (JOCKEY PUMP) Multistage centrifugal vertical electric pumps. All metal parts in contact with pumped liquid are made of stainless steel. Version F: round flanges, in-line discharge and suction ports, AISI 34 (Standard version). Version N: round flanges, in-line discharge and suction ports, AISI 316 (Available on request). Reduced axial thrusts enable the use of standard motors that are easily found in the market. Standard supplied IE2 three-phase surface motors,7 kw are compliant with Regulation (EC) no. 64/29. Mechanical seal according to EN 1276 (ex DIN 2496) and ISO 369. Easy maintenance. No special tools required for assembly or disassembly. For other characteristics, consult the relative dedicated technical catalogue. FHF32, 4,, 6, 8, 1, 12 PUMP SERIES Single impeller cast iron horizontal centrifugal pump and shaft made of AISI 316L stainless steel. End suction and radial discharge ports. Impeller: made of AISI 316L stainless steel laser technology welded, for sizes 32, 4,, 6-12, or cast iron for sizes 6-16, 6-2, 6-2, 8, 1, 12. Hydraulic sizes and nominal diameter DN of suction and discharge ports according to EN 733 (ex DIN 242). Flanges according to EN (ex UNI 2236) and DIN 232. Motor: motor/pump coupling with bracket, support, flexible coupling with spacer coupling and aligning and anchoring base. Standard supplied IE2 three-phase surface motors,7 kw are compliant with Regulation (EC) no. 64/29 and IEC Performance levels according to EN Back pull out design, impeller, adaptor and motor can be extracted without disconnecting the pump body from the pipes. For other characteristics, consult the relative dedicated technical catalogue. SHF32, 4,, 6, 8 PUMP SERIES Single impeller horizontal centrifugal pump with pump body and shaft made of AISI 316L stainless steel. End suction and radial discharge ports. Closed impeller made of AISI 316L stainless steel laser technology welded (for sizes 2, 32, 4,, 6-16/7 and 6-16/11A) or AISI CF8M cast stainless steel. Hydraulic sizes and nominal diameter DN of suction and discharge ports according to EN 733 (ex DIN 242). Flanges according to EN (ex UNI 2236) and DIN 232. Motor: motor/pump coupling with bracket, support, flexible coupling with spacer coupling and aligning and anchoring base. Standard supplied IE2 three-phase surface motors,7 kw are compliant with Regulation (EC) no. 64/29 and IEC Performance levels according to EN Back pull out design, impeller, adaptor and motor can be extracted without disconnecting the pump body from the pipes. For other characteristics, consult the relative dedicated technical catalogue. 1
11 MAIN COMPONENTS FIRE-FIGHTING DIESEL ENGINE PUMP (D..) Diesel engine with coupling to service pump. Electric panel for control of diesel engine pump and battery charger. Diesel engine start circuit with two independent batteries. Double engine starting relay. Engine shut-off device from electric control (Electric stop). Fuel tank for diesel engine equipped with float. Base made of structural steel with epoxy powder painting RAL 1. The diesel engine pump is mounted on its own base complete with vibration-damping feet, and comes with a wall-mounted electric panel fitted with 3-metre cables ( metre length available on request), fuel tank with wall or floor mounting depending on capacity, floor-mounted or on-board batteries. Special versions of additional diesel fuel tank available on request. A panel mounting bracket kit for floor mounting and a jockey pump kit can be supplied on request. The installation of the diesel engine must provide for adequate ventilation and exhaust of combustion fumes. INTRODUCTION FIRE-FIGHTING SETS WITH DIESEL ENGINE PUMP (GEN..D) FIRE-FIGHTING SETS WITH ELECTRIC PUMP AND DIESEL ENGINE (GEN..D) On/off valves on the delivery side of each pump, ball valves with lever handle for diameters up to and including 1" 1/2 butterfly valve with lever handle from DN to DN1 diameter, butterfly valve with handwheel and reduction manual gear for DN12 diameter and above. Device for monitoring ON/OFF status included. Electrical connections by customer. (Lockable kit available on request). Recirculation device for each service pump. The re-circulation device allows a minimum capacity in order to prevent the pump overheating when working with closed delivery. It includes the activation pressure switch for the alarms of the pumps running, the test valve for checking the seal of the check valves, the couplings for any connecting pipes to the priming tank in the case of suction lift installation. The connection of each re-circulation to the suction tank or the priming tank is to be seen to by the person installing the equipment. Pressure gauge on the delivery side of each service pump between check valve and on/off valve. Inspectable check valve on the discharge side of each pump. Threaded coupling for diameters up to 1"1/2 included, flanged coupling for larger sizes. Painted iron delivery manifold (PN 16) and threaded stubs with relative caps for connecting any 24 litre membrane tanks. Blind and welding zinc-plated flanges. Two start-up pressure switches for every service pump. For the electric service pumps, start-up takes place through the pressure switch, but it must be manually stopped using the key-operated selector switch on the panel (excluding the version with automatic shut-off). For the electric jockey pump, if present, both start-up and stopping are determined by the pressure switch. Start-up pressure switch circuit for the service pump, including connecting pipes for the delivery manifold, recirculation circuit. This circuit includes on/off valve, a non-return valve, a discharge valve and various pipe fittings. The configuration of the circuit allows the pressure switch to intervene also when the relative on/off valve is closed. Various pipe fittings (copper, zinc-plated steel). Base made of bent sheet or structural iron with epoxy powder painting RAL 1. Control panel frame made of structural iron with epoxy powder painting RAL 1. Diesel engine with coupling to service pump. Vibration-damping joints on discharge side. Electric panel for control of diesel engine pump and battery charger. Diesel engine start circuit with two independent batteries. Length of cable connecting the batteries to the connection box 3 m. Double engine starting relay. Engine shut-off device from electric control (Electric stop). 11
12 Fuel tank for diesel engine. Special versions of additional diesel fuel tank available on request. Electric panel for each electric service pump. Starting: Direct (DOL) up to and including 22 kw, star/triangle from 3 kw up. INTRODUCTION The diesel engine pump is mounted on its own base complete with vibration-damping feet, and comes with a wall-mounted electric panel fitted with 3-metre cables ( metre length available on request), fuel tank with wall or floor mounting depending on capacity, floor-mounted or on-board batteries depending on size. A panel mounting bracket kit for floor mounting and a jockey pump kit can be supplied on request. The installation of the diesel engine must provide for adequate ventilation and exhaust of combustion fumes. The control panels for the electric pumps up to kw power supply are fixed on bracket. For higher powers, the control panels for electric pump service are floor mounted, instead the jockey electric pump panel is wall mounted fixed. Sets featuring a single diesel engine pump plus jockey pump are equipped with electric jockey pump with 1 x 23V single-phase power supply. SUCTION KIT The set is supplied with its suction side free from components. On request, for the SUCTION side of the individual service pump, TWO versions are available according to the system s installation type: POSITIVE SUCTION HEAD and SUCTION LIFT KIT Kit suitable for positive suction head or suction lift installation. The suction side of the individual pump includes: - Anti-vibration joint to attach to the pump inlet. - Eccentric cone or flanged stub pipe. - Vacuum pressure gauge. - On/off butterfly valve (optional in case of positive suction head installation) with lever handle for diameters up to DN1, butterfly valve with handwheel and reduction manual gear for DN12 and higher. Device for monitoring ON/OFF status included. Electrical connections by customer. (Valve lock kit available on request). - Weld-on flange. Conforming to the requirements of the EN 1284 Standard (chapter 1. and chapter 1.6). These requirements are connected with the type of installation and the measurement of the piping sections. (see tables on pages ). OTHER VERSIONS As well as the basic GENDB versions (direct start-up), GENYB (star triangle start-up), GENIB (impedance start-up), the following versions are also available: GEN..A With periodic self-test function. There is a self-test circuit including a weekly clock on the electric panel of each electric service pump. For the time and date pre-set, the pump is started up and kept functioning for 1 minute. During this interval the check circuit checks that the pressure in the re-circulation circuit closes the pressure switch contact of the pump which is running. In the case of irregularities, the relative auxiliary self-test alarm relay available for remote signalling is activated and memorised. The EN1284 Standard does not provide for the presence of a self-test circuit but asks for periodic checks to be carried out by the user, hence the periodic self-test function cannot substitute the above checks. GEN..X GEN..X (For fire hydrant systems, UNI 1779) With automatic shut-off. There is an automatic shut-off circuit on the electric panel of each electric service pump. In certain situations, it allows automatic shut-off once the system pressure has been kept at higher values than the start-up values for at least twenty minutes. The self-test and automatic shut-off versions are available for each type of GEND.., GENY.., GENI.. start-up and in combination between them (See identification codes page). 12
13 ACCESSORIES SORIES AVAILABLE AILABLE ON REQUEST Protection against dry running for the electric jockey pump in one of the following versions: - Float switch, in case of suction lift. - Probes kit in case of suction lift (needs optional probe module in the electric jockey pump). - Minimum pressure switch, in case of positive suction head. Electric panel for remote status and alarm monitoring of one or two Lowara pumps installed in GEN fire-fighting booster sets, according to EN1284. In the electric service pump mode, the following conditions are visualised: Motor powered, pump start-up request, pump running, failure to start. In the diesel engine service pump mode, the following conditions are visualised: switch in non-automatic position, diesel engine fails to start after 6 attempts, pump running, QAL1284 Panel controller failure. Additionally: minimum suction tank or fuel level, minimum priming tank level, on-off valve on suction and discharge side not fully open. All the above conditions, required by EN1284, are visualised with signal LED s and buzzers. A buzzer alarm reset button and LED tester button are included. The control unit is also fitted out to signal the following general alarms, if present: - General alarm for incorrect electrical connection in the exchange contacts of: flow meter circuit valve, discharge pump, jockey pump status. - Fault in electrical connection in the exchange contact relative to panel 1 (electric pump/diesel engine pump). - Fault in electrical connection in the exchange contact relative Flow meter to panel 2 (electric pump/diesel engine pump). - Jockey pump overload; - Jockey pump running; - Discharge pump overload; - Battery low; - No communication with ModBus system. All the above conditions are visualised with signal LED s and on the display. The customer may decide to enable the buzzer. Further information available on page 144. Circuit for test flow of the service pumps. Includes the direct reading flow meter (sized according to the capacity of the service pump) according to the type of flow meter, connecting piping and straight piping upline from the instrument, on/off ball valve for diameters up to and including 2 butterfly valve with lever handle from DN6 to DN1 diameter, butterfly valve with handwheel and reduction manual gear for DN12 diameter and above. ON/OFF status monitoring included. New model of flow meter (P6) for diameters up to and including DN8. Diaphragm tank with relative ball valve, in the same number as that of the pumps present, for dampening any pressure oscillations in the system. 24 litre model with maximum pressure 8, 1 and 16 bar or 2 litre model with maximum pressure 2 bar according to the maximum head of the pumps. Priming tank for each service pump, in the case of suction lift installation. Accessories for the priming tank suck as float switch tap, level indicator, valves, automatic air discharger on each service pump, in the case of suction lift installation. INTRODUCTION All the main characteristics of the priming tanks, the flow meters and the available membrane tanks are shown in the accessories section. 13
14 SPECIAL EQUIPMENT ON REQUEST (Contact the Sales and technical Assistance Service) Sets for pumping sea water with electric pumps, valves, manifold and AISI 316 piping or compatible alloys. INTRODUCTION Non-standard supply power sets. Sets with two diesel engine service pumps. (See page 1). Sets with separate electric jockey pump supplied as a kit. Sets installed inside prefabricated boxes for outdoor use. Sets with oversized fuel tank. Sets with diesel engine pump with compressed air start system. Diesel engine pump with ambient air cooling device. Notes The set is supplied without a suction manifold in accordance with the EN1284 Standard (points and ) which provides for independent suction for each pump. Please see the EN1284 Standard on fixed systems and fire extinguishing Automatic sprinkler systems Design, installation and maintenance?- for sizing the suction piping, define whether the installation is to be considered suction lift or positive suction head for the use limits. The Standard ask that, whenever possible, the pumps are installed with positive suction head, otherwise priming tanks must be provided with suitable automatic devices for signalling and reintegration. The EN1284 Standard states that the water pressure should not exceed 12 bar (point 8.2.1). In some applications it is possible to have pressures of over 12 bar (point 8.2.2). In this case, pump sets with higher pressures than those within the regulatory limit are used. The catalogue also shows booster sets with pump closing head up to 1 metres suitable for such installations. 14
15 SPECIAL EQUIPMENT ON REQUEST INTRODUCTION 1
16 COMMAND PANEL FOR THE ELECTRIC SERVICE PUMP Painted metal casing (IP 4) complete with: INTRODUCTION General door-locking switch. Analogical ammeter. MAN AUT selector with extractable key only in automatic position. Keyboard for indicating electric voltage presence, correct phase sequence (three phase power supply), start-up request, pump functioning and no start-up, through LED lamps, lamp test button and starting and stopping buttons, according to the provisions of EN1284 paragraph Inside: 12/24V transformer for auxiliary circuits and electronic board. Fuse holder and fuses for power and auxiliary circuits. Line contact maker (direct start-up up to 22 kw included), line and star/triangle contact makers (startriangle start-up), line contact makers and reactance switching (impedance start-up). Star/triangle exchanger timer or reactance switching. Relay for signalling no phase. Auxiliary relays. Current transformer. Terminal boards. Clean contacts (max. 24V, 1A) for activating acoustic/ visual alarms for no phase, pump on demand, pump running and start failure. Cable glands (excluding the versions to be fixed to the floor). Wiring diagram. Electric service pump panel 16
17 COMMAND PANEL FOR THE ELECTRIC JOCKEY PUMP Painted metal casing (IP ) complete with: General door-locking switch. Visual indicators for line, running, thermal shutdown. Manual automatic selector excluded. Inside: Transformer for 24V auxiliary circuits. Fuse holder and fuses for power and auxiliary circuits. Line contact maker. Overload cut-out switch. Pump shut-off timer ( 9 s). Terminal boards. Cable glands. Wiring diagram. INTRODUCTION Suitable for connecting to a float switch or a minimum pressure switch for preventing dry running. An optional level control module (supplied on request) allows the connection of probes with the possibility of regulating the sensitivity according to the hardness of the water. Electric jockey pump panel OPTIONS AVAILABLE AILABLE ON REQUEST CP alternative Series of clean contacts for checking the status of the electric service pump panel, as well as the contacts already provided for signalling alarms: No phase Motor running Selector position MAN-AUT- No start-up Start-up request Series of clean contacts for checking the status of the electric jockey pump: Pump running Thermal shutdown (overload) No water KV alternative Control panel for the electric service pump with analogical voltmeter and with phase switch. IP alternative Electric service pump panel with extra IP protection. 17
18 COMMAND PANEL FOR DIESEL ENGINE PUMP Painted metal casing (IP 4) complete with: INTRODUCTION Electronic control and management unit for the diesel engine. Display of alarms and status, battery voltage, speedometer, hour counter, alarm programming, date display, main signals and manual start button. Man-Auto- selector switch with key removable only in the auto position. Pair of emergency battery start buttons. General door-locking switch. Inside: Fuse holder and fuses for power and auxiliary circuits. Pair of battery chargers 12Vdc/24Vdc. Control unit for management of diesel engine and alarms. Auxiliary relays. Power circuits for engine heaters. Terminal boards. RS232 connector for communication port. Cable glands. Wiring diagram. Diesel engine pump panel The panel is supplied standard with clean alarm signal contacts (max. 1A,3Vdc/12Vac/277Vac): Non-automatic operating mode. Controller fault. Motor running. Failure to start. General alarm. Single-phase 1x23V standard power supply. OPTIONS AVAILABLE AILABLE ON REQUEST IP alternative Diesel engine service pump panel with additional IP protection. The set is supplied already assembled, calibrated and factory tested. The set is supplied complete with an instruction manual, pump manuals and wiring diagrams for the panels. For the sets including floor panels, the electric panels are sent together with the set in a separate pack and supplied with -metre long connecting cables (longer lengths available on request). The fitter is responsible for preparing the routes and installing the cables. 18
19 COMMAND PANEL DIMENSIONS SERVICE PUMP PANEL POWER (kw) PROTECTION B L H CLASS from,7 to 7, IP from 9,2 to 22 IP from 3 to 37 IP4 2 7 from 4 to IP from 7 to 9 IP from 11 to 16 IP IP: same dimensions as standard panels IP4 qe-serv-en_d_td Power over kw: floor cupboard INTRODUCTION JOCKEY PUMP PANEL PROTECTION CLASS B L H IP IP: same dimensions as standard panels IP4 qe-pil-en_b_td ENGINE PUMP PANEL PROTECTION CLASS B L H IP4 3 2 IP: same dimensions as standard panels IP4 qe-mtp1284_en_b_td * The control panels are included in the supply. 19
20 EN 1284 DIESEL ENGINE PUMP TANKS DIMENSIONS AND CAPACITY ACITY INTRODUCTION VOLUME (litres) B L H TYPE serb-mtp-en_b_td Note: Special versions of additional diesel fuel tank available on request. 2
21 EN 1284 DIESEL ENGINE PUMP TANKS COMBINATIONS AND POSITIONING PUMP CAPACITY' (l) D.. GEN..D GEN..1D GEN..1D GEN..11D FHF32-12/D119 3 FHF32-12/D136 3 FHF32-16/D1 3 FHF32-16/D164 3 WALL MOUNTED WALL MOUNTED ON BOARD ON BOARD ON BOARD FHF32-2/D188 3 FHF32-2/D24 3 FHF4-12/D112 3 FHF4-12/D122 3 FHF4-12/D143 3 FHF4-16/D19 3 FHF4-16/D171 3 FHF4-2/D19 3 WALL MOUNTED WALL MOUNTED ON BOARD ON BOARD ON BOARD FHF4-2/D29 3 FHF4-2/D218 3 FHF4-2/D233 3 FHF4-2/D21 3 FHF-12/D119 3 FHF-12/D13 3 FHF-12/D139 3 FHF-16/D18 3 FHF-16/D174 3 FHF-2/D197 3 WALL MOUNTED WALL MOUNTED ON BOARD ON BOARD ON BOARD FHF-2/D29 3 FHF-2/D224 3 FHF-2/D237 6 FHF-2/D2 6 FHF6-12/D121 3 FHF6-12/D129 3 FHF6-12/D14 3 FHF6-16/D161 3 FHF6-16/D168 3 FHF6-16/D178 3 WALL MOUNTED WALL MOUNTED ON BOARD ON BOARD ON BOARD FHF6-2/D187 3 FHF6-2/D198 6 FHF6-2/D21 6 FHF6-2/D22 6 FHF6-2/D241 6 FHF6-2/D28 9 FLOOR-MOUNTED FLOOR-MOUNTED FLOOR-MOUNTED FLOOR-MOUNTED FLOOR-MOUNTED FHF8-16/D163 3 FHF8-16/D173 6 FHF8-2/D189 6 FHF8-2/D27 6 FHF8-2/D22 9 FHF8-2/D238 9 FHF8-2/D26 13 WALL MOUNTED WALL MOUNTED ON BOARD ON BOARD ON BOARD FLOOR-MOUNTED FLOOR-MOUNTED FLOOR-MOUNTED FLOOR-MOUNTED FLOOR-MOUNTED pos-serb-fhf1284-en_c_td INTRODUCTION 21
22 EN 1284 DIESEL ENGINE PUMP TANKS COMBINATIONS AND POSITIONING PUMP CAPACITY' (l) D.. GEN..D GEN..1D GEN..11D INTRODUCTION FHF1-16/D1 3 FHF1-16/D16 6 FHF1-16/D18 6 WALL MOUNTED WALL MOUNTED ON BOARD ON BOARD FHF1-2/D168 6 FHF1-2/D192 6 FHF1-2/D23 9 FHF1-2/D213 9 FLOOR-MOUNTED FLOOR-MOUNTED FLOOR-MOUNTED FLOOR-MOUNTED FHF1-2/D2 6 WALL MOUNTED WALL MOUNTED ON BOARD ON BOARD FHF1-2/D221 9 FHF1-2/D23 13 FHF1-2/D24 19 FLOOR-MOUNTED FLOOR-MOUNTED FLOOR-MOUNTED FLOOR-MOUNTED FHF1-2/D FHF12-2/D18 6 WALL MOUNTED WALL MOUNTED ON BOARD ON BOARD FHF12-2/D26 9 FHF12-2/D FHF12-27/D FHF12-27/D FLOOR-MOUNTED FLOOR-MOUNTED FLOOR-MOUNTED FLOOR-MOUNTED FHF12-27/D23 24 FHF12-27/D pos-serb-fhf en_c_td 22
23 EN 1284 DIESEL ENGINE PUMP TANKS COMBINATIONS AND POSITIONING PUMP CAPACITY' (l) D.. GEN..D GEN..1D GEN..1D GEN..11D SHF32-12/D121 3 SHF32-12/D136 3 SHF32-16/D1 3 SHF32-16/D168 3 SHF32-2/D188 3 WALL MOUNTED WALL MOUNTED ON BOARD ON BOARD ON BOARD SHF32-2/D24 3 SHF32-2/D222 3 SHF32-2/D242 3 SHF32-2/D26 3 SHF4-12/D112 3 SHF4-12/D126 3 SHF4-12/D143 3 SHF4-16/D19 3 SHF4-16/D171 3 SHF4-2/D19 3 WALL MOUNTED WALL MOUNTED ON BOARD ON BOARD ON BOARD SHF4-2/D29 3 SHF4-2/D218 3 SHF4-2/D233 3 SHF4-2/D21 3 SHF-12/D119 3 SHF-12/D13 3 SHF-12/D139 3 SHF-16/D18 3 SHF-16/D174 3 SHF-2/D197 3 WALL MOUNTED WALL MOUNTED ON BOARD ON BOARD ON BOARD SHF-2/D29 3 SHF-2/D224 3 SHF-2/D237 6 SHF-2/D2 6 SHF6-16/D119 3 SHF6-16/D129 3 SHF6-16/D137 3 SHF6-16/D168 3 SHF6-16/D177 3 WALL MOUNTED WALL MOUNTED ON BOARD ON BOARD ON BOARD SHF6-2/D192 3 SHF6-2/D23 6 SHF6-2/D21 6 SHF6-2/D24 6 SHF6-2/D2 9 FLOOR-MOUNTED FLOOR-MOUNTED FLOOR-MOUNTED FLOOR-MOUNTED FLOOR-MOUNTED SHF8-16/D169 3 SHF8-16/D177 3 SHF8-16/D186 6 WALL MOUNTED WALL MOUNTED ON BOARD ON BOARD ON BOARD SHF8-2/D198 6 SHF8-2/D21 6 SHF8-2/D226 9 SHF8-2/D237 9 SHF8-2/D22 13 FLOOR-MOUNTED FLOOR-MOUNTED FLOOR-MOUNTED FLOOR-MOUNTED FLOOR-MOUNTED SHF8-2/D27 19 pos-serb-shf1284-en_c_td INTRODUCTION 23
24 STARTING BATTERIES TERIES FOR DIESEL ENGINE PUMP EN 1284 COMBINATIONS AND SIZES INTRODUCTION TABELLA ABBINAMENTI POMPA SERVIZIO FH BATTERIA AVVIAM. MTP GR TABLE OF DIESEL ENGINE PUMP FHF COMBINATIONS DIESEL BATTERY DIESEL BATTERY ENGINE PUMP TYPE ENGINE PUMP TYPE TYPE TYPE DFHFE.. A B C D E DFHFE.. A B C D E PUMP PUMP 32-12/D /D /D /D /D1 6-2/D /D /D /D /D /D24 6-2/D /D /D /D /D /D /D /D19 8-2/D /D /D22 4-2/D19 8-2/D /D29 8-2/D26 4-2/D /D1 4-2/D /D16 4-2/D /D18-12/D /D168-12/D13 1-2/D192-12/D /D23-16/D18 1-2/D213-16/D /D2-2/D /D221-2/D29 1-2/D23-2/D /D24-2/D /D267-2/D2 12-2/D /D /D /D /D /D /D /D /D /D /D /D /D FHF32-12_ab-en_a_tc 24
25 STARTING BATTERIES TERIES FOR DIESEL ENGINE PUMP EN 1284 TABLE TABELLA OF ABBINAMENTI DIESEL ENGINE POMPA SERVIZIO PUMP SHF SH BATTERIA COMBINATIONS AVVIAM. MTP GRU DIESEL BATTERY ENGINE PUMP TYPE 32-12/D /D /D /D /D /D /D /D /D /D /D /D /D /D /D19 4-2/D29 4-2/D /D /D21-12/D119-12/D13-12/D139-16/D18-16/D174-2/D197-2/D29-2/D224-2/D237-2/D2 6-16/D /D /D /D /D /D /D23 6-2/D21 6-2/D24 6-2/D2 8-16/D /D /D /D /D21 8-2/D /D /D22 8-2/D27 TYPE DSHFE.. PUMP A B C D 1284-SHF32-8_ab-en_a_tc E INTRODUCTION 2
26 GEN SERIES OF BOOSTER SETS CHOICE AND SELECTION Criteria for choosing fire-fighting sets INTRODUCTION The correct choice of a fire-fighting set must consider various factors, including the correct sizing of the performance levels required for the system, local regulations and legislation, and especially the installation conditions relative to the installation site and whether a suction lift or a positive suction head is involved. Choosing the type of water supply The type of water supply and, therefore, the type of booster set to select depends on the type of system involved and is chosen according to the risk analysis performed by the designer. There is no written rule for identifying the correct number of pumps to install. GEN booster sets are normally designed so that every service pump can satisfy the following requirements: 1% of rated capacity with one or two pumps installed (one in service and the other in reserve). If three pumps are installed, the capacity of the pump will be % of the total rated capacity and the third service pump will be considered as a reserve. In these cases, when superior or duplicated water supplies are involved, only one pump must be driven by an electric motor. This type of configuration is available on request. Suction conditions of the booster set The type of installation, suction lift or positive suction head, tends to affect (negatively or positively) the hydraulic performance of the pump. Remembering that EN1284 recommends against using suction lift installations, the following condition given by EN1284 must be satisfied in order to use the pump curve correctly: NPSHd NPSHr +1 [m] Where: NPSHd is defined available. NPSHr is defined requested from the pump. As the suction check condition must be made at the max. requested flow, there can be different performance levels always respecting the NPSHd condition. To select the booster set, consult the dedicated sections. Choice and selection. Hydraulic performance levels. Suction lift or positive suction head installation. Performance levels of booster sets: using the tables The tables showing the hydraulic performance levels of booster sets indicate the flow values according to the risk class for precalculated systems followed by the respective pressure value. This value does not refer to pump performance but is net of the pressure drop on the pump discharge line, to the discharge manifold flange. This field is shown in grey and the selection must be made here, where performance levels comply with the reference standard which considers the following conditions: Maximum water speed in the service pump discharge piping 6 m/sec. NPSHd NPSHr + 1 at the maximum flow required. Max. difference in level of water considered 3,2 m (for positive suction head). Suction pressure drops due to valves, piping, suction kit 1, m (limit value). The reference suction conditions are the severest and most extreme that can occur. The values taken in the fields that are not in grey indicate booster set performance levels in areas outside the limits of the standard and must not be used to choose the set. 26
27 GEN SERIES OF BOOSTER SETS CHOICE AND SELECTION Method of selecting a fire-fighting booster set Referring to EN 1284, after identifying the risk classes of the activity to protect and performing the precalculation method, the flow and head values required for the fire-fighting system can be obtained. This data is used as follows: 1. Configuration of the booster set, choice of the number of service pumps and relative type of motor/engine (two pumps, one electric and the other driven by a diesel engine). 2. Installation conditions (e.g.. positive suction head), see performance levels for positive suction head installation. 3. Determination of service flow e.g.: 11 l/min risk class OH3. TABELLA DI PRESTAZIONI IDRAULICHE NETTE GRUPPI EN1284 SERIE FHF 2 poli Hz 1 POMPA DI SERVIZIO, INST SOPRAB RISK CLASS INTRODUCTION TYPE RATED OH2n OH3n FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 11,8 3,7 1,8 8, TABELLA 4. Determining DI PRESTAZIONI the IDRAULICHE head e.g.: NETTE 3 GRUPPI m. EN1284 SERIE 2,2 FHF 2 poli Hz 113,1 POMPA DI SERVIZIO, INST SOPRAB 27,3 18,2 34,8 RISK 26, CLASS 42,8 31,2 TYPE RATED 49,9 38,6 FHF.. POWER 6,4 48,8 Q = DELIVERY 69, 8,8 l/min , , ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER -12/22-12/D119 1 x 2,2 16,8 13,7 12,3 11,8 9, 6,2 3,7,9-12/3-12/D13 1 x 3 19,9 17, 16,1 1,8 13,6 1, 8,,3 2,3-12/4-12/D139 1 x 4 24,3 21,8 2,6 2,2 18,3 1,3 13,1 1, 7,7 6,2 4,6-16/ -16/D18 1 x, 31,8 29,3 27,7 27,3 24,8 21,1 18,2 1, 11,4 9, 7,6-16/7-16/D174 1 x 7, 39,8 36,6 3,2 34,8 32, 29,1 26, 23, 2,2 18, 16,7 12,7-2/11A -2/D197 1 x 11,6 4,6 43,4 42,8 39, 34,8 31,2 27,3 23,1 2,9 18,6-2/11-2/D29 1 x 11 8, 2,6, 49,9 46,7 42,1 38,6 34,7 3,4 28,1 2,7 2,7 6,4 48,8 OH2n 69, 8,8 As can be seen, the required flow value enters the operating area in accordance with the standard, and the value of 79, 68,1 the corresponding head enters the field in grey. From the example shown above, we can identify the booster set that satisfies the request. The model is pump -2/11 providing a head of 38,6 m. OH3n 27
28 GEN SERIES OF BOOSTER SETS CHOICE AND SELECTION - POSITIVE SUCTION HEAD INSTALLA ALLATION EN1284 recommends always installing pumps in suction lift conditions, where possible If this is not possible, the pumps can be installed in positive suction head conditions according to the following rules: INTRODUCTION The height of the minimum water level at the pump axis must not be greater than 3,2 m. A foot valve must be installed in the lowest point of the suction piping. If more than one pump is installed, the suction piping must not be interconnected. optional Normal Liv. normale level Max 3,2 m Liv. Min X Min. level X Fig. 1 positive suction head installation diagram In accordance with EN 1284 ( ), the suction piping, including all the valves and unions, must be designed to ensure that the NPSH available at the pump inlet exceeds the required NPSH by at least 1 m at the maximum required flow rate. NPSHd NPSHr + 1 When selecting the type of pump to use for the boosters sets, the installation conditions must be considered as these determine different pump performance levels. An example of how to choose and check of the installation conditions is shown below: considering the precalculation method, a suitable risk class for the system is identified, e.g.: OH3. For this risk class, the rated flow is 11 l/min (Qn), while the maximum requested flow is 13 l/min (Qm). Being in a positive suction head condition, the most difficult situation is considered, i.e.: the maximum difference in water level of 3,2 m, as indicated in the standard. Being aware of the rated flow 11 l/min and the pressure required for the system (e.g.: 3 m), the pump is selected according to the tables on page 44-4, making sure the performance rating lies inside the area shown in grey. The pump that satisfies the required work point is FHF-2/11. 28
29 GEN SERIES OF BOOSTER SETS CHOICE AND SELECTION - POSITIVE SUCTION HEAD INSTALLA ALLATION At this point, the installation conditions (positive suction head) must be checked at the maximum required flow. The following values are replaced in the known relation, NPSHd NPSHr + 1: NPSHr can be deduced from the table on page 4 which in this case is 4,6 m at the maximum requested flow. After replacing the value, the following will be true (water temperature around 1 C): NPSHd = 1,33 + (-3,2) - Hct Where 1,33 atmospheric pressure 3,2 geodetic difference in level Hct suction pressure drop ((valves, pipes, elbows..) The value of Hct considers the pressure drops of the suction kit, inclusive of vibration-proof joint, reduction cone and on-off valve (Hc), as well as the pressure drops relative to all the suction piping, foot valve, elbows, elbows, etc... INTRODUCTION The value of Hc at the maximum required flow of the selected pump can be found in the diagram on page 81. This value is,16 m. After entering it in the formula, we will have: Hct =,16 + X Where X is the pressure drop relative to all the suction piping Hence NPSHd NPSHr + 1. After replacing this, we will have: 1,33 + (-3,2) - Hct = 4,6 +1 1,33 + (-3,2),16 - X = 4,6 +1 which gives X = 1,37 m Maximum value of total drops to consider on the inlet piping in order to respect the conditions of the standard. Of course, this case was deliberately put in the worst suction conditions. The designer must check and set the values in an attempt to optimise suction conditions. 29
30 GEN SERIES OF BOOSTER SETS CHOICE AND SELECTION - POSITIVE SUCTION HEAD INSTALLA ALLATION Checking performance of the set at rated flow. INTRODUCTION The performance of the booster set must now be checked in the installation conditions of the example used up until now. Work point: Qn: 11 l/min H = 3 m The selected pump is FHF-2/11 Starting from the usual relation given by the standard, we will have: NPSHd NPSHr + 1 NPSHd = 1,33 + (-3,2) - Hct NPSHr can be deduced from the table on page 4 which in this case is 2,9 m at the rated flow. The value of Hct considers the pressure drops of the suction kit, inclusive of vibration-proof joint, reduction cone and on-off valve (Hc), as well as the pressure drops relative to all the suction piping, foot valve, elbows, elbows, etc... The value of Hc at the rated required flow of the selected pump can be found in the diagram on page 81. This value is,12 m. After entering it in the formula, we will have: Hct =,12 + X Where X is the pressure drop relative to all the suction piping Hence NPSHd NPSHr + 1. After replacing this, we will have: 1,33 + (-3,2) - Hct = 2,9 +1 1,33 + (-3,2),12 - X = 2,9 +1 which gives X = 3,11 m Value of the total drops to consider on the suction piping Taking the pressure value of the selected set, the value corresponds to 38,6 m at the rated flow. Therefore, the verification of the pressure values in the above suction conditions becomes: H = 38,6 -,12-3,11 = 3,4 m > 3 m which is the pressure required for the system The result satisfies the performance required for the system in the installation conditions of the example. 3
31 GEN SERIES OF BOOSTER SETS CHOICE AND SELECTION - SUCTION LIFT INSTALLA ALLATION Suction lift installation EN1284 recommends always installing pumps in suction lift conditions, where possible, according to the following rules: At least two thirds of the effective capacity of the suction tank must be above the level of the pump axis. The pump axis must not be more than 2 m above the minimum water level in the suction tank. Liv. Normal normale level INTRODUCTION 2/3 della of capacità effective effettiva capacity Max 2 m Liv. Min. Min level X Fig. 2 suction lift installation diagram In accordance with EN 1284 ( ), the suction piping, including all the valves and unions, must be designed to ensure that the NPSH available at the pump inlet exceeds the required NPSH by at least 1 m at the maximum required flow rate. NPSHd NPSHr + 1 When selecting the type of pump to use for the boosters sets, the installation conditions must be considered as these determine different pump performance levels. An example of how to choose and check of the installation conditions is shown below: considering the precalculation method, a suitable risk class for the system is identified, e.g.: OH3. For this risk class, the rated flow is 11 l/min (Qn), while the maximum requested flow is 13 l/min (Qm). Being in the suction lift condition, a neutral situation is used in order to consider the water level on the same horizontal plane as the pump, without benefiting from any positive suction head. 31
32 GEN SERIES OF BOOSTER SETS CHOICE AND SELECTION - SUCTION LIFT INSTALLA ALLATION Being aware of the rated flow 11 l/min and the pressure required for the system (e.g.: 3 m), the pump is selected according to the tables on page 44-4, making sure the performance rating lies inside the area shown in grey. The pump that satisfies the required work point is FHF-2/11. INTRODUCTION At this point, the installation conditions (suction lift) must be checked at the maximum required flow. The following values are replaced in the known relation, NPSHd NPSHr + 1: NPSHr can be deduced from the table on page 4 which in this case is 4,6 m at the maximum requested flow. After replacing the value, the following will be true (water temperature around 1 C): NPSHd = 1,33 + () - Hct Where 1,33 atmospheric pressure geodetic difference in level Hct suction pressure drop (valves, pipes, elbows...) The value of Hct considers the pressure drops of the suction kit, inclusive of vibration-proof joint, reduction cone and on-off valve (Hc), as well as the pressure drops relative to all the suction piping, foot valve, elbows, elbows, etc The value of Hc at the maximum required flow of the selected pump can be found in the diagram on page 87. This value is,32 m. After entering it in the formula, we will have: Hct =,32 + X Where X is the pressure drop relative to all the suction piping Hence NPSHd NPSHr + 1. After replacing this, we will have: 1,33 + () - Hct = 4,6 +1 1,33 + (),32 - X = 4,6 +1 which gives X = 4,41 m Maximum value of total drops to consider on the inlet piping in order to respect the conditions of the standard. Of course, the case in point was deliberately tested in neutral suction conditions that neither benefit nor optimise suction. The designer must check and set the values in an attempt to make suction conditions as efficient as possible. 32
33 GEN SERIES OF BOOSTER SETS CHOICE AND SELECTION - SUCTION LIFT INSTALLA ALLATION Checking performance of the selected set at rated flow. The performance of the booster set must now be checked in the installation conditions of the example used up until now. Work point: Qn 11 l/min H = 3 m The selected pump is FHF-2/11 Starting from the usual relation given by the standard, we will have: NPSHd NPSHr + 1 NPSHd = 1,33 + () - Hct NPSHr can be deduced from the table on page 4 which in this case is 2,9 m at the rated flow. INTRODUCTION The value of Hct considers the pressure drops of the suction kit, inclusive of vibration-proof joint, reduction cone and on-off valve (Hc), as well as the pressure drops relative to all the suction piping, foot valve, elbows, elbows, etc... The value of Hc at the rated required flow of the selected pump can be found in the diagram on page 87. This value is,22 m. After entering it in the formula, we will have: Hct =,22 + X Where X is the pressure drop relative to all the suction piping Hence NPSHd NPSHr + 1. After replacing this, we will have: 1,33 + () - Hct = 2,9 +1 1,33 + (),22 - X = 2,9 +1 which gives X = 6,21 m Value of the total drops to consider on the suction piping Taking the pressure value of the selected set, the value corresponds to 38,6 m at the rated flow. Therefore, the verification of the pressure values in the above suction conditions becomes: H = 38,6 -,22-6,21 = 32,17 m < 3 m which is the pressure required for the system. The value obtained, doesn t satisfy the performance necessary for the system, but as is evident, we have used deliberately a neutral installation condition that it doesn t give benefits to the suction. It results that installed the pump with positive suction of 3 m, we will have a pressure value of 3,17 m that it satisfied the relation. 33
34 INTRODUCTION 34
35 GEN..D/FHF Series Fire-fighting booster sets EN 1284, electric pumps FHF series with high efficiency motors and diesel engine pumps Hz GEN..D/FHF 3
36 GEN..D/FHF 36
37 RANGE GEN..D/FHF RANGE The range of EN 1284 fire-fighting booster sets with diesel and electric service pumps and optional jockey pump to adapt to the specific needs of every application. D.. ENGINE PUMP Single fire-fighting centrifugal pump in horizontal design with cast iron casing, FHF series. Head up to 1 m. Flow up to 6 m 3 /h. GEN..D SERIES Fire-fighting sets with diesel engine centrifugal service pump, in horizontal design with cast iron casing, FHF series. Head up to 1 m. Flow up to 6 m 3 /h. GEN..D/FHF GEN..1D SERIES Fire-fighting sets with diesel engine service pump and electric jockey pump. The centrifugal service pump has horizontal design and cast iron casing. FHF series. Head up to 1 m. Flow up to 6 m 3 /h. GEN..1D SERIES Fire-fighting sets with diesel engine service pump and electric jockey pump. The centrifugal service pump has horizontal design and cast iron casing. FHF series. Head up to 1 m. Flow up to 13 m 3 /h. GEN..11D SERIES Fire-fighting sets with diesel engine service pump, electric service pump and electric jockey pump. The centrifugal service pump has horizontal design and cast iron casing. FHF series. Head up to 1 m. Flow up to 13 m 3 /h. 37
38 GEN..D/FHF GEN..D/FHF BOOSTER SETS SERIES HYDRAULIC TABELLA DI PRESTAZIONI PERFORMANCE IDRAULICHE TABLE SERIE AT 1SV 3SV Hz SV (JOCKEY 2p Hz PUMP) PUMP TYPE NOMINAL POWER l/min 12 2 Q = DELIVERY m 3 /h,7 1,2 1, 1,8 2,1 2,4 kw HP H = TOTAL HEAD METRES COLUMN OF WATER 1SV 2,37, 12,2 12,2 11, 1,7 9, 7,9 6, 1SV 3,37, 18, 18, 17, 1,7 13,8 11,4 8,4 1SV 4,37, 23,7 23, 22,1 2,4 17,9 14,6 1,6 1SV,37, 29,3 28,9 27, 24,8 21,6 17,4 12, 1SV 6,37, 34,8 34,2 31,7 28,9 2, 2, 14, 1SV 7,37, 4,2 39,2 36,1 32,7 28,1 22,2 1,2 1SV 8,,7 48,1 47,9 4,2 41,8 36,8 3,4 22,4 1SV 9,,7 3,7 3,4,4 46,4 4,8 33, 24,6 1SV 1,,7 9,4 9,, 1, 44,7 36,6 26,6 1SV 11,,7 6,1 64, 6,4, 48, 39, 28, 1SV 12,7 1 73,3 73,1 69,3 64,3 7,1 47,6 3,7 1SV 13,7 1 79,2 78,9 74,8 69,4 61,6 1,2 38,2 1SV 1,7 1 9,9 9, 8,6 79,3 7,1 8,1 43,1 1SV 17 1,1 1, 1,2 14,9 1, 93,1 82,6 68,6 1,2 1SV 19 1,1 1, 117, 116,7 111, 13,2 91, 7,8 6,3 1SV 22 1,1 1, 134,6 134,1 127,4 118,1 14,4 86,1 63, 1SV 2 1, 2 12,6 12,4 14, 13,4 12, 99,1 72,7 Prestazioni conformi alle norme ISO Annex A. EN1284_pp_1sv-2p-en_a_th 38
39 GEN..D/FHF 32-8 BOOSTER SETS SERIES SERVICE TABELLA ABBINAMENTI PUMP JOCKEY POMPA SERVIZIO PUMP COMBINATIONS FH POMPA PILOTA GRUPPI GEN 1 SERVICE PUMP JOCKEY PUMP ELECTRIC PUMP TYPE FHF.. PUMP 32-12/ /D / /D / /D / /D /3 32-2/D /4 32-2/D / /D /1 4-12/D / /D /3 4-16/D /4 4-16/D / 4-2/D19 4-2/7 4-2/D29 4-2/11A 4-2/D /11 4-2/D /1 4-2/D21-12/22-12/D119-12/3-12/D13-12/4-12/D139-16/ -16/D18-16/7-16/D174-2/11A -2/D197-2/11-2/D29-2/1-2/D224-2/18-2/D237-2/22-2/D2 6-12/4 6-12/D / 6-12/D /7 6-12/D /11A 6-16/D / /D /1 6-16/D /1 6-2/D /18 6-2/D /22 6-2/D21 6-2/22 6-2/D22 6-2/3 6-2/D /37 6-2/D /1 8-16/D / /D /22 8-2/D /3 8-2/D27 8-2/37 8-2/D22 8-2/4 8-2/D / 8-2/D26 1SV 7 1SV 8 1SV 9 1SV 1 1SV 11 1SV 12 1SV 13 1SV 1 1SV 17 1SV FHF32-8_ap-en_b_tc GEN..D/FHF 39
40 GEN..D/FHF 1-12 BOOSTER SETS SERIES SERVICE TABELLA ABBINAMENTI PUMP JOCKEY POMPA SERVIZIO PUMP COMBINATIONS FH POMPA PILOTA GRUPPI GE SERVICE PUMP JOCKEY PUMP GEN..D/FHF ELECTRIC PUMP TYPE FHF.. PUMP 1SV / /D1 1-16/ /D /3 1-16/D18 1-2/18 1-2/D /3 1-2/D /37 1-2/D23 1-2/4 1-2/D /3 1-2/D2 1-2/4 1-2/D / 1-2/D23 1-2/7 1-2/D24 1-2/9 1-2/D /3 12-2/D /4 12-2/D / 12-2/D / /D / /D / /D / /D266 1SV 8 1SV 9 1SV 1 1SV 11 1SV 12 1SV 13 1SV 1 1SV 17 1SV FHF1-12_ap-en_b_tc 4
41 HYDRAULIC PERFORMANCE TABLE AT HZ (POSITIVE SUCTION HEAD) TABELLA DI PRESTAZIONI IDRAULICHE NETTE GRUPPO EN1284 SERIE FHF32 2 poli Hz, 1 POMPA DI SERVIZIO, ASP ESCLUSA INS SOPRA GEN..D/FHF 32 BOOSTER SETS SERIES RISK CLASS TYPE RATED LHn FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 32-12/ /D119 1 x,7 16,9 1,6 14,1 12,1 1,9 9,6 8,1 6, / /D136 1 x 1,1 21,9 2, 19,1 17,2 16,1 14,9 13, 12,1 7,1, / /D1 1 x 1, 27,3 2,6 24, 21,8 2, 19, 17,4 1,6 9, 7, / /D164 1 x 2,2 34,7 33,1 31, 29,3 27,9 26, 24,9 23,2 17,3 1, 12,7 1,2 32-2/3 32-2/D188 1 x 3 44,2 41,3 39,3 36,8 3,3 33,7 32, 3,1 23,4 2,8 18, 1, 32-2/4 32-2/D24 1 x 4 4,4 1,7 49, 46,8 4,2 43, 41,7 39,7 33,2 3,8 28,2 2,6 2, Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-sp-fhf32-2p-en_a_th LHn = class of risk value referred to the required rated capacity (Tab.6 para EN1284) Inlet pressure drops must be deducted. Make sure that these drops, added to the difference in level (max. 3.2m), are less than 4.m The values shown identify performance levels according to the reference standard EN1284. HYDRAULIC PERFORMANCE TABLE AT HZ (SUCTION LIFT) GEN..D/FHF 32 BOOSTER SETS SERIES TABELLA DI PRESTAZIONI IDRAULICHE NETTE GRUPPO EN1284 SERIE FHF32 2 poli Hz, 1 POMPA DI SERVIZIO, ASP ESCLUSA INS SOTTO TYPE RATED FHF.. POWER l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 32-12/ /D119 1 x,7 16,9 1,6 14,1 12,1 1,9 9,6 8,1 6, / /D136 1 x 1,1 21,9 2, 19,1 17,2 16,1 14,9 13, 12,1 7,1, / /D1 1 x 1, 27,3 2,6 24, 21,8 2, 19, 17,4 1,6 9, 7, / /D164 1 x 2,2 34,7 33,1 31, 29,3 27,9 26, 24,9 23,2 17,3 1, 12,7 1,2 32-2/3 32-2/D188 1 x 3 44,2 41,3 39,3 36,8 3,3 33,7 32, 3,1 23,4 2,8 18, 1, 32-2/4 32-2/D24 1 x 4 4,4 1,7 49, 46,8 4,2 43, 41,7 39,7 33,2 3,8 28,2 2,6 2, Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-st-fhf32-2p-en_a_th LHn = class of risk value referred to the required rated capacity (Tab.6 para EN1284) Inlet pressure drops must be deducted. Make sure these drops are less than 4.m The values shown identify performance levels according to the reference standard EN1284. LHn RISK CLASS Q = DELIVERY GEN..D/FHF TABELLA DI PRESTAZIONI IDRAULICHE NPSHr GRUPPI EN1284 SERIE FHF32 2 poli Hz NPSH REQUIRED FOR PUMP SERIES FHF 32 RISK CLASS TYPE RATED LHn FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m 3 /h PUMP kw NPSHr [METRES COLUMN OF WATER] 32-12/ /D119 1 x,7 1,6 1,6 1,7 1,8 2, 2, / /D136 1 x 1,1 1,6 1,6 1,7 1,8 2, 2,2 2,9 3,4 4, 32-16/ /D1 1 x 1, 2,2 2,4 2, 2,7 2,8 3, 3,6 3,9 4, / /D164 1 x 2,2 2,2 2,4 2, 2,7 2,8 3, 3,6 3,9 4,4,9 32-2/3 32-2/D188 1 x 3 2,7 2,9 3,1 3,3 3, 3,8 4,3 4,6 4,9, 32-2/4 32-2/D24 1 x 4 2,7 2,9 3,1 3,3 3, 3,8 4,3 4,6 4,9, 6,2 The declared NPSH values were obtained in the laboratory and refer to a single service pump 1284_1p-fhf32-2p_NPSHr-en_a_th LHn = class of risk value referred to the required rated capacity (Tab.6 para EN1284) Check that NPSHd NPSHr+1m is satisfied 41
42 HYDRAULIC TABELLA DI PRESTAZIONI PERFORMANCE IDRAULICHE NETTE GRUPPI EN1284 TABLE SERIE AT FHF4 2 poli HZ Hz (POSITIVE 1 POMPA DI SERVIZIO, SUCTION ASP ESCLUSA INST HEAD) SOPRAB GEN..D/FHF 4 BOOSTER SETS SERIES RISK CLASS TYPE RATED OH1n GEN..D/FHF FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 4-12/ /D112 1 x 1,1 13,9 11,3 1, 9,3 3,4,7 4-12/1 4-12/D122 1 x 1, 18, 1,3 14, 13,3 7,4 4,7 4-12/ /D143 1 x 2,2 2,3 21,8 2, 19,8 14, 11,4 6,4, 3,6,6 4-16/3 4-16/D19 1 x 3 31,6 28,1 26,8 26, 19, 16, 1,8 9,2 7,6 4-16/4 4-16/D171 1 x 4 38,3 3,1 33,7 32,9 26, 23,6 18,1 16, 1, 11,7 4-2/ 4-2/D19 1 x, 46,4 42,7 41,2 4,4 33,1 29,7 23,3 21, 19,6 4-2/7 4-2/D29 1 x 7, 7, 3,1 1,6,7 43,8 4,7 34,8 33,2 31, 28, 4-2/11A 4-2/D218 1 x 11 63,6 7,8 6,2,2 47,8 44, 38,2 36, 34,8 31,1 4-2/11 4-2/D233 1 x 11 71,7 66, 64,3 63,4,7 2,3 4,8 44, 42,1 38,3 4-2/1 4-2/D21 1 x 1 8, 78,6 76,9 76, 68,4 6, 8,6 6,8, 1,1 42,6 Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-sp-fhf4-2p-en_a_th OHn = class of risk value referred to the required rated capacity (Tab.6 para EN1284) Inlet pressure drops must be deducted. Make sure that these drops, added to the difference in level (max. 3.2m), are less than 4.m The values shown identify performance levels according to the reference standard EN1284. HYDRAULIC PERFORMANCE TABLE AT HZ (SUCTION LIFT) GEN..D/FHF 4 BOOSTER SETS SERIES TABELLA DI PRESTAZIONI IDRAULICHE NETTE GRUPPI EN1284 SERIE FHF4 2 poli Hz 1 POMPA DI SERVIZIO, ASP ESCLUSA INST SOTTO RISK CLASS TYPE RATED OH1n FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 4-12/ /D112 1 x 1,1 13,9 11,3 1, 9,3 3,4,7 4-12/1 4-12/D122 1 x 1, 18, 1,3 14, 13,3 7,4 4,7 4-12/ /D143 1 x 2,2 2,3 21,8 2, 19,8 14, 11,4 6,4, 3,6,6 4-16/3 4-16/D19 1 x 3 31,6 28,1 26,8 26, 19, 16, 1,8 9,2 7,6 4-16/4 4-16/D171 1 x 4 38,3 3,1 33,7 32,9 26, 23,6 18,1 16, 1, 11,7 4-2/ 4-2/D19 1 x, 46,4 42,7 41,2 4,4 33,1 29,7 23,3 21, 19,6 4-2/7 4-2/D29 1 x 7, 7, 3,1 1,6,7 43,8 4,7 34,8 33,2 31, 28, 4-2/11A 4-2/D218 1 x 11 63,6 7,8 6,2,2 47,8 44, 38,2 36, 34,8 31,1 4-2/11 4-2/D233 1 x 11 71,7 66, 64,3 63,4,7 2,3 4,8 44, 42,1 38,3 4-2/1 4-2/D21 1 x 1 8, 78,6 76,9 76, 68,4 6, 8,6 6,8, 1,1 42,6 Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-st-fhf4-2p-en_a_th OHn = class of risk value referred to the required rated capacity (Tab.6 para EN1284) Inlet pressure drops must be deducted. Make sure these drops are less than 4.m The values shown identify performance levels according to the reference standard EN
43 NPSH REQUIRED FOR PUMP SERIES FHF 4 TABELLA DI PRESTAZIONI IDRAULICHE NPSHr GRUPPI EN1284 SERIE FHF4 2 poli Hz 1 POMPA DI SERVIZIO RISK CLASS TYPE RATED OH1n OH1m FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m 3 /h PUMP kw NPSHr [METRES COLUMN OF WATER] 4-12/ /D112 1 x 1,1 1,8 1,9 1,9 2,4 2,7 4-12/1 4-12/D122 1 x 1, 1,8 1,9 1,9 2,4 2,7 3,7 4-12/ /D143 1 x 2,2 1,8 1,9 1,9 2,4 2,7 3,7 4,1 4,6 6,3 4-16/3 4-16/D19 1 x 3 1,9 1,9 1,9 2,4 2,9 4,1 4,, 4-16/4 4-16/D171 1 x 4 1,9 1,9 1,9 2,4 2,9 4,1 4,, 6,2 4-2/ 4-2/D19 1 x, 2, 2,1 2,2 2,9 3,4 4, 4,9,3 4-2/7 4-2/D29 1 x 7, 2, 2,1 2,2 2,9 3,4 4, 4,9,3 6,3 4-2/11A 4-2/D218 1 x 11 1, 1,1 1,2 1,6 1,7 2,1 2,2 2,3 2,6 4-2/11 4-2/D233 1 x 11 1, 1,1 1,2 1,6 1,7 2,1 2,2 2,3 2,6 4-2/1 4-2/D21 1 x 1 1, 1,1 1,2 1,6 1,7 2,1 2,2 2,3 2,6 3, The declared NPSH values were obtained in the laboratory and refer to a single service pump OHn, OHm = class of risk value referred to the required rated and maximum capacity (Tab.6 para EN1284) Check that NPSHd NPSHr+1m is satisfied at the maximum requested capacity 1284_1p-fhf4-2p_NPSHr-en_a_th GEN..D/FHF 43
44 HYDRAULIC TABELLA DI PRESTAZIONI PERFORMANCE IDRAULICHE NETTE GRUPPI EN1284 TABLE SERIE AT FHF 2 poli HZ Hz (POSITIVE 1 POMPA DI SERVIZIO, SUCTION INST SOPRAB HEAD) GEN..D/FHF BOOSTER SETS SERIES RISK CLASS TYPE RATED OH2n OH3n GEN..D/FHF FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER -12/22-12/D119 1 x 2,2 16,8 13,7 12,3 11,8 9, 6,2 3,7,9-12/3-12/D13 1 x 3 19,9 17, 16,1 1,8 13,6 1, 8,,3 2,3-12/4-12/D139 1 x 4 24,3 21,8 2,6 2,2 18,3 1,3 13,1 1, 7,7 6,2 4,6-16/ -16/D18 1 x, 31,8 29,3 27,7 27,3 24,8 21,1 18,2 1, 11,4 9, 7,6-16/7-16/D174 1 x 7, 39,8 36,6 3,2 34,8 32, 29,1 26, 23, 2,2 18, 16,7 12,7-2/11A -2/D197 1 x 11,6 4,6 43,4 42,8 39, 34,8 31,2 27,3 23,1 2,9 18,6-2/11-2/D29 1 x 11 8, 2,6, 49,9 46,7 42,1 38,6 34,7 3,4 28,1 2,7 2,7-2/1-2/D224 1 x 1 68,1 62,8 6,9 6,4 7,3 2,6 48,8 44,4 39,4 36,7 33,8-2/18-2/D237 1 x 18, 76, 71,7 7, 69, 66,6 62,3 8,8 4,7, 47,4 44,7 38,6-2/22-2/D2 1 x 22 86, 81,2 79, 79, 76,1 71,7 68,1 64, 9,4 6,8 4,1 48,1 41,4 Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-sp-fhf-2p-en_a_th OHn = class of risk value referred to the required rated capacity (Tab.6 para EN1284) Inlet pressure drops must be deducted. Make sure that these drops, added to the difference in level (max. 3.2m), are less than 4.m The values shown identify performance levels according to the reference standard EN1284. HYDRAULIC PERFORMANCE TABLE AT HZ (SUCTION LIFT) TABELLA DI PRESTAZIONI IDRAULICHE NETTE GRUPPI EN1284 SERIE FHF 2 poli Hz 1 POMPA DI SERVIZIO, INST SOTT GEN..D/FHF BOOSTER SETS SERIES RISK CLASS TYPE RATED OH2n OH3n FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER -12/22-12/D119 1 x 2,2 16,8 13,7 12,3 11,8 9, 6,2 3,7,9-12/3-12/D13 1 x 3 19,9 17, 16,1 1,8 13,6 1, 8,,3 2,3-12/4-12/D139 1 x 4 24,3 21,8 2,6 2,2 18,3 1,3 13,1 1, 7,7 6,2 4,6-16/ -16/D18 1 x, 31,8 29,3 27,7 27,3 24,8 21,1 18,2 1, 11,4 9, 7,6-16/7-16/D174 1 x 7, 39,8 36,6 3,2 34,8 32, 29,1 26, 23, 2,2 18, 16,7 12,7-2/11A -2/D197 1 x 11,6 4,6 43,4 42,8 39, 34,8 31,2 27,3 23,1 2,9 18,6-2/11-2/D29 1 x 11 8, 2,6, 49,9 46,7 42,1 38,6 34,7 3,4 28,1 2,7 2,7-2/1-2/D224 1 x 1 68,1 62,8 6,9 6,4 7,3 2,6 48,8 44,4 39,4 36,7 33,8-2/18-2/D237 1 x 18, 76, 71,7 7, 69, 66,6 62,3 8,8 4,7, 47,4 44,7 38,6-2/22-2/D2 1 x 22 86, 81,3 79, 79, 76,1 71,7 68,2 64,1 9, 6,9 4,2 48,2 41,6 Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-st-fhf-2p-en_a_th OHn = class of risk value referred to the required rated capacity (Tab.6 para EN1284) Inlet pressure drops must be deducted. Make sure these drops are less than 4.m The values shown identify performance levels according to the reference standard EN
45 NPSH REQUIRED FOR PUMP SERIES FHF TABELLA DI PRESTAZIONI IDRAULICHE NPSHr GRUPPI EN1284 SERIE FHF 2 poli Hz 1 POMPA DI SERVIZIO RISK CLASS TYPE RATED OH2n OH2m OH3n OH3m FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m 3 /h PUMP kw NPSHr [METRES COLUMN OF WATER] -12/22-12/D119 1 x 2,2 2,1 2,3 2,3 2,6 3,1 3, 3,9-12/3-12/D13 1 x 3 2,1 2,3 2,3 2,6 3,1 3, 3,9 4,4-12/4-12/D139 1 x 4 2,1 2,3 2,3 2,6 3,1 3, 3,9 4,4 4,7, -16/ -16/D18 1 x, 1,9 2,1 2,2 2, 2,9 3,2 3,6 4,2 4,6,1-16/7-16/D174 1 x 7, 1,9 2,1 2,2 2, 2,9 3,2 3,6 4,2 4,6,1 6, -2/11A -2/D197 1 x 11 1,8 1,9 2, 2,2 2,6 2,9 3,4 4,1 4,6,1-2/11-2/D29 1 x 11 1,8 1,9 2, 2,2 2,6 2,9 3,4 4,1 4,6,1 6,7-2/1-2/D224 1 x 1 1, 1,7 1,7 2, 2,4 2,7 3,1 3,6 3,9 4,2-2/18-2/D237 1 x 18, 1, 1,7 1,7 2, 2,4 2,7 3,1 3,6 3,9 4,2,1-2/22-2/D2 1 x 22 1, 1,7 1,7 2, 2,4 2,7 3,1 3,6 3,9 4,2,1 6,4 The declared NPSH values were obtained in the laboratory and refer to a single service pump OHn, OHm = class of risk value referred to the required rated and maximum capacity (Tab.6 para EN1284) Check that NPSHd NPSHr+1m is satisfied at the maximum requested capacity 1284_1p-fhf-2p_NPSHr-en_a_th GEN..D/FHF 4
46 HYDRAULIC PERFORMANCE TABLE AT HZ (POSITIVE SUCTION HEAD) TABELLA DI PRESTAZIONI IDRAULICHE NETTE GRUPPI EN1284 SERIE FHF6 2 poli Hz 1 POMPA DI SERVIZIO, ASP ESCLUSA INST SOPRAB GEN..D/FHF 6 BOOSTER SETS SERIES RISK CLASS TYPE RATED OH3n OH4n GEN..D/FHF FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 6-12/4 6-12/D121 1 x 4 19,1 1,6 14,6 13, 12,3 1,9 8,7 7,9 6,2 6-12/ 6-12/D129 1 x, 22,7 19,6 18,8 17,8 16,7 1, 13, 12,7 11,2,7 6-12/7 6-12/D14 1 x 7, 27,1 24,3 23, 22,7 21,7 2,7 18,9 18,2 16,8 12, 8,1 6-16/11A 6-16/D161 1 x 11 32,7 29,2 28,3 27,2 26, 23,9 23,2 21,6 1,9 11, 9, 6-16/ /D168 1 x 11 3,9 32, 31, 3, 29,4 27,4 26,7 2,2 19,8 1,6 13,3 6-16/1 6-16/D178 1 x 1 41,9 38,9 38,1 37,1 36,1 34,2 33,6 32,2 27,2 23,2 21,1 16,3 6-2/1 6-2/D187 1 x 1 4,2 43,4 42,3 41,1 39,7 37,3 36,4 34,6 28,4 23,8 21,3 6-2/18 6-2/D198 1 x 18, 1,6,2 49,2 48,2 47, 44,9 44,1 42,4 36, 31,8 29,2 6-2/22 6-2/D21 1 x 22 9,1 7,2 6,3,3 4,2 2,1 1,4 49,8 44,1 39,6 37,1 31,6 6-2/22 6-2/D22 1 x 22 62,8 6,6 9,4 8, 6,4 3, 2,,2 42,1 3,7 32,1 6-2/3 6-2/D241 1 x 3 76,4 7, 73,9 72,6 71,1 68, 67, 6,4 7,8 1,6 48,2 4,6 6-2/37 6-2/D28 1 x 37 9,8 89,9 89, 88, 86,7 84, 83,7 81,8 74,8 68,8 6,4 7,7 Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-sp-fhf6-2p-en_a_th OHn = class of risk value referred to the required rated capacity (Tab.6 para EN1284) Inlet pressure drops must be deducted. Make sure that these drops, added to the difference in level (max. 3.2m), are less than 4.m The values shown identify performance levels according to the reference standard EN1284. HYDRAULIC PERFORMANCE TABLE AT HZ (SUCTION LIFT) GEN..D/FHF 6 BOOSTER SETS SERIES TABELLA DI PRESTAZIONI IDRAULICHE NETTE GRUPPI EN1284 SERIE FHF6 2 poli Hz 1 POMPA DI SERVIZIO, ASP ESCLUSA INST SOTTOB RISK CLASS TYPE RATED OH3n OH4n FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 6-12/4 6-12/D121 1 x 4 19,1 1,6 14,6 13, 12,3 1,9 8,7 7,9 6,2 6-12/ 6-12/D129 1 x, 22,7 19,6 18,8 17,8 16,7 1, 13, 12,7 11,2,7 6-12/7 6-12/D14 1 x 7, 27,1 24,3 23, 22,7 21,7 2,7 18,9 18,2 16,8 12, 8,1 6-16/11A 6-16/D161 1 x 11 32,7 29,2 28,3 27,2 26, 23,9 23,2 21,6 1,9 11, 9, 6-16/ /D168 1 x 11 3,9 32, 31, 3, 29,4 27,4 26,7 2,2 19,8 1,6 13,3 6-16/1 6-16/D178 1 x 1 41,9 38,9 38,1 37,1 36,1 34,2 33,6 32,2 27,2 23,2 21,1 16,3 6-2/1 6-2/D187 1 x 1 4,2 43,4 42,3 41,1 39,7 37,3 36,4 34,6 28,4 23,8 21,3 6-2/18 6-2/D198 1 x 18, 1,6,2 49,2 48,2 47, 44,9 44,1 42,4 36, 31,8 29,2 6-2/22 6-2/D21 1 x 22 9,1 7,2 6,3,3 4,2 2,1 1,4 49,8 44,1 39,6 37,1 31,6 6-2/22 6-2/D22 1 x 22 62,8 6,6 9,4 8, 6,4 3, 2,,2 42,1 3,7 32,1 6-2/3 6-2/D241 1 x 3 76,4 7, 73,9 72,6 71,1 68, 67, 6,4 7,8 1,6 48,2 4,6 6-2/37 6-2/D28 1 x 37 9,8 89,9 89, 88, 86,7 84, 83,7 81,8 74,8 68,8 6,4 7,7 Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-st-fhf6-2p-en_a_th OHn = class of risk value referred to the required rated capacity (Tab.6 para EN1284) Inlet pressure drops must be deducted. Make sure these drops are less than 4.m The values shown identify performance levels according to the reference standard EN
47 NPSH REQUIRED FOR PUMP SERIES FHF 6 TABELLA DI PRESTAZIONI IDRAULICHE NPSHr GRUPPI EN1284 SERIE FHF6 2 poli Hz 1 POMPA DI SERVIZIO RISK CLASS TYPE RATED OH3n OH3m OH4n OH4m FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m 3 /h PUMP kw NPSHr [METRES COLUMN OF WATER] 6-12/4 6-12/D121 1 x 4 1, 1,2 1,3 1,6 1,9 2,4 2,6 3,1 6-12/ 6-12/D129 1 x, 1, 1,2 1,3 1,6 1,9 2,4 2,6 3,1,1 6-12/7 6-12/D14 1 x 7, 1, 1,2 1,3 1,6 1,9 2,4 2,6 3,1,1 7, 6-16/11A 6-16/D161 1 x 11 2,4 2,4 2, 2,6 2,9 2,9 3,2 4,2,3 6, 6-16/ /D168 1 x 11 2,3 2,4 2, 2,7 2,8 2,9 3,1 3,7 4,4 4,9 6-16/1 6-16/D178 1 x 1 2,3 2,4 2, 2,7 2,8 2,9 3,1 3,7 4,4 4,9 6,6 6-2/1 6-2/D187 1 x 1 1,8 1,9 2, 2,1 2,3 2,4 2,6 3,4 4,,3 6-2/18 6-2/D198 1 x 18, 1,8 1,9 2, 2,1 2,3 2,4 2,6 3,4 4,3 4,9 6-2/22 6-2/D21 1 x 22 1,8 1,9 2, 2,1 2,3 2,4 2,6 3,4 4,3 4,9 6,6 6-2/22 6-2/D22 1 x 22 1,7 2, 2,2 2, 2,9 3,1 3,4 4,3,,4 6-2/3 6-2/D241 1 x 3 1,7 2, 2,2 2, 2,9 3,1 3,4 4,3,,4 6,2 6-2/37 6-2/D28 1 x 37 1,7 2, 2,2 2, 2,9 3,1 3,4 4,3,,4 6,2 The declared NPSH values were obtained in the laboratory and refer to a single service pump 1284_1p-fhf6-2p_NPSHr-en_a_th OHn, OHm = class of risk value referred to the required rated and maximum capacity (Tab.6 para EN1284) Check that NPSHd NPSHr+1m is satisfied at the maximum requested capacity GEN..D/FHF 47
48 HYDRAULIC TABELLA DI PRESTAZIONI PERFORMANCE IDRAULICHE NETTE GRUPPI EN1284 TABLE SERIE AT FHF8 2 poli HZ Hz (POSITIVE 1 POMPA DI SERVIZIO, SUCTION ASP ESCLUSA INST HEAD) SOPRA GEN..D/FHF 8 BOOSTER SETS SERIES RISK CLASS TYPE RATED OH4n HH1n GEN..D/FHF FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 8-16/1 8-16/D163 1 x 1 32,9 3,2 29,1 27,8 2,4 24,9 23,8 22,7 18,8 9,4 4,4 8-16/ /D173 1 x 18, 39, 3,6 34, 33,4 31,2 3,7 29,7 28,6 2,1 16,2 11,3 9, 8, 8-2/22 8-2/D189 1 x 22 48, 44,7 43,4 41,8 39, 38,3 37, 3,6 3,9 19,2 12,8 8-2/3 8-2/D27 1 x 3 9,9 6,9,8 4,4 1,9 1,3,1 48,9 44,7 34,2 28, 26,4 2,3 8-2/37 8-2/D22 1 x 37 7,8 67,3 6,8 63,9 6,4 9,6 7,9 6,1,1 34,7 26,1 8-2/4 8-2/D238 1 x 4 8, 78, 76, 74,8 71, 7,8 69,2 67,6 62, 47, 39,6 36, 8-2/ 8-2/D26 1 x 88,9 89,9 88,8 87, 84,8 84,2 82,9 81, 76,7 64, 6,7 4, 2,6 Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-sp-fhf8-2p-en_a_th OHn, HHn = class of risk value referred to the required rated capacity (Tab.6 para 7.3.1, Tab.7 para EN1284) Inlet pressure drops must be deducted. Make sure that these drops, added to the difference in level (max. 3.2m), are less than 4.m The values shown identify performance levels according to the reference standard EN1284. HYDRAULIC PERFORMANCE TABLE AT HZ (SUCTION LIFT) GEN..D/FHF 8 BOOSTER SETS SERIES TABELLA DI PRESTAZIONI IDRAULICHE NETTE GRUPPI EN1284 SERIE FHF8 2 poli Hz 1 POMPA DI SERVIZIO, ASP ESCLUSA INST SOTTO RISK CLASS TYPE RATED OH4n HH1n FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 8-16/1 8-16/D163 1 x 1 32,9 3,2 29,1 27,8 2,4 24,9 23,8 22,7 18,8 9,4 4,4 8-16/ /D173 1 x 18, 39, 3,6 34, 33,4 31,2 3,7 29,7 28,6 2,1 16,2 11,3 9, 8, 8-2/22 8-2/D189 1 x 22 48, 44,7 43,4 41,8 39, 38,3 37, 3,6 3,9 19,2 12,8 8-2/3 8-2/D27 1 x 3 9,9 6,9,8 4,4 1,9 1,3,1 48,9 44,7 34,2 28, 26,4 2,3 8-2/37 8-2/D22 1 x 37 7,8 67,3 6,8 63,9 6,4 9,6 7,9 6,1,1 34,7 26,1 8-2/4 8-2/D238 1 x 4 8, 78, 76, 74,8 71, 7,8 69,2 67,6 62, 47, 39,6 36, 8-2/ 8-2/D26 1 x 88,9 89,9 88,8 87, 84,8 84,2 82,9 81, 76,7 64, 6,7 4, 2,6 Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-st-fhf8-2p-en_a_th OHn, HHn = class of risk value referred to the required rated capacity (Tab.6 para 7.3.1, Tab.7 para EN1284) Inlet pressure drops must be deducted. Make sure these drops are less than 4.m The values shown identify performance levels according to the reference standard EN
49 NPSH REQUIRED FOR PUMP SERIES FHF 8 TABELLA DI PRESTAZIONI IDRAULICHE NPSHr GRUPPI EN1284 SERIE FHF8 2 poli Hz 1 POMPA DI SERVIZIO RISK CLASS TYPE RATED OH4n OH4m HH1n HH1m FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m 3 /h PUMP kw NPSHr [METRES COLUMN OF WATER] 8-16/1 8-16/D163 1 x 1 3,7 3,8 3,9 4, 4,1 4,2 4,2 4,,4 6,2 8-16/ /D173 1 x 18, 3,7 3,8 3,9 4, 4,1 4,2 4,2 4,,4 6,2 6, 6,8 8-2/22 8-2/D189 1 x 22 2,8 3, 3,1 3,3 3,4 3, 3,6 3,9,1 6,3 8-2/3 8-2/D27 1 x 3 2,8 3, 3,1 3,3 3,4 3, 3,6 3,9,1 6,3 6,9 7,3 8-2/37 8-2/D22 1 x 37 3, 3,1 3,3 3,6 3,6 3,8 3,9 4,4 6, 7,4 8-2/4 8-2/D238 1 x 4 2,4 2,6 2,7 3, 3,1 3,2 3,3 3,8 4,9,,7 8-2/ 8-2/D26 1 x 2,4 2,6 2,7 3, 3,1 3,2 3,3 3,8 4,9,,7,8 The declared NPSH values were obtained in the laboratory and refer to a single service pump 1284_1p-fhf8-2p_NPSHr-en_a_th OHn, OHm, HHn, HHm = class of risk value referred to the required rated and maximum capacity (Tab.6 para 7.3.1, Tab.7 para EN1284) Check that NPSHd NPSHr+1m is satisfied at the maximum requested capacity GEN..D/FHF 49
50 HYDRAULIC PERFORMANCE TABLE AT HZ (POSITIVE SUCTION HEAD) GEN..D/FHF 1 BOOSTER SETS SERIES RISK CLASS TYPE RATED HH1n HH2n HH3n HH4n FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 1-16/ /D1 1 x 18, 26,7 26, 2,6 2,2 22,9 19,9 19, 18, 13,9 11,8 1,2 9,6 3, 1,8 1-16/ /D16 1 x 22 33, 32,2 31,7 31,2 28,7 2,3 24,4 23,3 18,8 16,6 14,8 14,2 7,6,9 4,2 2,2 1-16/3 1-16/D18 1 x 3 42,3 41,2 4,8 4,3 37,8 34,6 33,6 32, 28,2 26, 24,2 23,6 16,9 1,1 13, 11,4,3 1-2/18 1-2/D168 1 x 18, 36,3 33, 32,7 28,6 23, 22, 2,3 13, 1,1 7,4 6,4 1-2/3 1-2/D192 1 x 3 49, 47, 46,9 43,7 39, 38,3 36,8 31, 28, 2, 24,7 1, 12,9 1-2/37 1-2/D23 1 x 37 6, 4,6 4, 1, 46,9 4,8 44,4 38,7 3,8 33,4 32,6 23,7 21,2 18,9 16, 1-2/4 1-2/D213 1 x 4 61, 6, 9, 7,1 3,6 2,6 1,4 46,3 43,7 41, 4,7 32,3 29,9 27,7 24,8 1-2/3 1-2/D2 1 x 3 4,6 2,1 47,7 41,8 4, 37,9 29,3 24,8 21,2 19,9,9 1-2/4 1-2/D221 1 x 4 68,8 66,9 63, 8,7 7,2,4 48,1 44,2 41, 39,9 27,2 23,6 2,3 1,9 1-2/ 1-2/D23 1 x 78, 76,9 74, 69,8 68, 66,9 6,2 6,6 3,6 2,6 4,6 37,2 34, 29,8 RISK CLASS GEN..D/FHF TYPE RATED FHF.. POWER HH4n l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 1-2/7 1-2/D24 1 x 7 91,7 9, 86,9 7,9 71,7 66,1 63,7 62,1 8,7 2,9 49,3 38,3 29,3 28, 1-2/9 1-2/D267 1 x 9 12,9 11,6 98,2 87, 83,4 77,9 7,6 74, 7,7 64,9 61,3, 41, 4,2 38, 32, 31,1 Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-sp-fhf1-2p-en_b_th HHn = class of risk value referred to the required rated capacity (Tab.7 par EN1284) Inlet pressure drops must be deducted. Make sure these drops, added to the difference in level (max 3,2mt), are less than 4,mt The values shown identify performance levels according to the reference standard EN1284. HYDRAULIC PERFORMANCE TABLE AT HZ (SUCTION LIFT) GEN..D/FHF 1 BOOSTER SETS SERIES HHn HH6n Q = DELIVERY RISK CLASS TYPE RATED HH1n HH2n HH3n HH4n FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 1-16/ /D1 1 x 18, 26,7 26, 2,6 2,2 22,9 19,9 19, 18, 13,9 11,8 1,2 9,6 3, 1,8 1-16/ /D16 1 x 22 33, 32,2 31,7 31,2 28,7 2,3 24,4 23,3 18,8 16,6 14,8 14,2 7,6,9 4,2 2,2 1-16/3 1-16/D18 1 x 3 42,3 41,2 4,8 4,3 37,8 34,6 33,6 32, 28,2 26, 24,2 23,6 16,9 1,1 13, 11,4,3 1-2/18 1-2/D168 1 x 18, 36,3 33, 32,7 28,6 23, 22, 2,3 13, 1,1 7,4 6,4 1-2/3 1-2/D192 1 x 3 49, 47, 46,9 43,7 39, 38,3 36,8 31, 28, 2, 24,7 1, 12,9 1-2/37 1-2/D23 1 x 37 6, 4,6 4, 1, 46,9 4,8 44,4 38,7 3,8 33,4 32,6 23,7 21,2 18,9 16, 1-2/4 1-2/D213 1 x 4 61, 6, 9, 7,1 3,6 2,6 1,4 46,3 43,7 41, 4,7 32,3 29,9 27,7 24,8 1-2/3 1-2/D2 1 x 3 4,6 2,1 47,7 41,8 4, 37,9 29,3 24,8 21,2 19,9,9 1-2/4 1-2/D221 1 x 4 68,8 66,9 63, 8,7 7,2,4 48,1 44,2 41, 39,9 27,2 23,6 2,3 1,9 1-2/ 1-2/D23 1 x 78, 76,9 74, 69,8 68, 66,9 6,2 6,6 3,6 2,6 4,6 37,2 34, 29,8 RISK CLASS TYPE RATED HH4n HHn HH6n FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 1-2/7 1-2/D24 1 x 7 91,7 9, 86,9 7,9 71,7 66,1 63,7 62,1 8,7 2,9 49,3 38,3 29,3 28, 1-2/9 1-2/D267 1 x 9 12,9 11,6 98,2 87, 83,4 77,9 7,6 74, 7,7 64,9 61,3, 41, 4,2 38, 32, 31,1 Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-st-fhf1-2p-en_b_th HHn = class of risk value referred to the required rated capacity (Tab.7 par EN1284) Inlet pressure drops must be deducted. Make sure these drops are less than 4,mt The values shown identify performance levels according to the reference standard EN1284.
51 NPSH REQUIRED FOR PUMP SERIES FHF 1 RISK CLASS TYPE RATED HH1n HH2n HH3n HH1m HH4n HH2m HH3m HH4m FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw NPSHr [METRES COLUMN OF WATER] 1-16/ /D1 1 x 18, 6,3 6,4 6,6 7,3 8, 8,2 8,4 9,2 9, 9,8 9,9 11, 11,4 1-16/ /D16 1 x 22,,2,4 6,2 6,9 7, 7,2 7,9 8,3 8, 8,6 9,6 9,9 1,3 1,7 1-16/3 1-16/D18 1 x 3,,2,4 6,2 6,9 7, 7,2 7,9 8,3 8, 8,6 9,6 9,9 1,3 1,7 12,8 1-2/18 1-2/D168 1 x 18, 4,2 4,2 4,6,6 6, 6, 9,2 11,1 12,8 13, 1-2/3 1-2/D192 1 x 3 3,1 3,1 3,3 3, 3,6 3,7 4,2 4,6 4,9,1 7, 7,7 1-2/37 1-2/D23 1 x 37 3,1 3,1 3,3 3, 3,6 3,7 4,2 4,6 4,9,1 7, 7,7 8,4 9, 1-2/4 1-2/D213 1 x 4 3,1 3,1 3,3 3, 3,6 3,7 4,2 4,6 4,9,1 7, 7,7 8,4 9, 1-2/3 1-2/D2 1 x 3 4,7,,3,4,4,7,8,9 6, 6,3 1-2/4 1-2/D221 1 x 4 4,6 4,7 4,7 4,8 4,8 4,8 4,9 4,9 4,9,1,2,2,3 1-2/ 1-2/D23 1 x 4,6 4,7 4,7 4,8 4,8 4,8 4,9 4,9 4,9,1,2,2,3 TYPE RATED HH4n FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw NPSHr [METRES COLUMN OF WATER] 1-2/7 1-2/D24 1 x 7 4,6 4,7 4,8 4,9,,,,1,2,3,8 6,6 6,7 1-2/9 1-2/D267 1 x 9 4,6 4,7 4,8 4,9,,,,1,2,3,8 6,6 6,7 6,9 7,8 7,9 The declared NPSH values were obtained in the laboratory and refer to a single service pump 1284_1p-fhf1-2p_NPSHr-en_a_th HHn, HHm = class of risk value referred to the required rated and maximum capacity (Tab.7 para EN1284) Check that NPSHd NPSHr+1m is satisfied at the maximum requested capacity HHn HH6n RISK CLASS HH4m HHm HH6m GEN..D/FHF 1
52 HYDRAULIC PERFORMANCE TABLE AT HZ (POSITIVE SUCTION HEAD) TABELLA DI PRESTAZIONI IDRAULICHE NETTE GRUPPI EN1284 SERIE FHF12 2 poli Hz 1 POMPA DI SERVIZIO, ASP ESCLUSA INST SOPRA GEN..D/FHF 12 BOOSTER SETS SERIES RISK CLASS TYPE RATED HH6n HH7n HH8n HH9n HH1n FHF.. POWER Q = DELIVERY l/min ELECTRIC PUM m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 12-2/3 12-2/D18 1 x 3 32,8 29,8 28,4 19,8 19,6 1,8 14,4 12,6 11,2 1,9 7,6 12-2/4 12-2/D26 1 x 4 47,2 44,8 43, 34,8 34,6 3,3 28,6 26,4 24, 24,1 19,7 16,6 13,9 12,1 12-2/ 12-2/D216 1 x 7,4,1 4, 4,6 4,4 41, 39,3 36,8 34,8 34,3 29,3 2,6 22,3 2, 17,4 14, / /D224 1 x 7 6,1 63,7 6,,8 1, 49,8 47,3 4,3 44,8 39,8 36,1 32,7 3, 27,9 24,6 22, / /D237 1 x 9 7,3 73,6 67, 66,8 62,8 61,1 8,8 6,8 6,3 1,2 47,4 43,8 41,4 38, 34,8 32,2 27, 12-27/ /D23 1 x 11 88,2 8,4 79,2 79, 7,1 73, 71,2 69,2 68,8 63, 9,,7 3, 49,9 4,8 42,8 37,6 33, / /D266 1 x , 94,8 88,6 88,4 84,7 83,2 81,1 79,2 78,8 74, 7,3 66,8 64, 61,7 8,,4,7 46,8 4, Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. HHn = class of risk value referred to the required rated capacity (Tab.7 par EN1284) Inlet pressure drops must be deducted. Make sure these drops, added to the difference in level (max 3,2mt), are less than 4,mt The values shown identify performance levels according to the reference standard EN _1pg-sp-fhf12-2p-en_b_th GEN..D/FHF HYDRAULIC PERFORMANCE TABLE AT HZ (SUCTION LIFT) TABELLA DI PRESTAZIONI IDRAULICHE NETTE GRUPPI EN1284 SERIE FHF12 2 poli Hz 1 POMPA DI SERVIZIO, ASP ESCLUSA INST SOTTOB GEN..D/FHF 12 BOOSTER SETS SERIES TYPE RATED HH6n HH7n HH8n HH9n FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 12-2/3 12-2/D18 1 x 3 32,8 29,8 28,4 19,8 19,6 1,8 14,4 12,6 11,2 1,9 7,6 12-2/4 12-2/D26 1 x 4 47,2 44,8 43, 34,8 34,6 3,3 28,6 26,4 24, 24,1 19,7 16,6 13,9 12,1 12-2/ 12-2/D216 1 x 7,4,1 4, 4,6 4,4 41, 39,3 36,8 34,8 34,3 29,3 2,6 22,3 2, 17,4 14, / /D224 1 x 7 6,1 63,7 6,,8 1, 49,8 47,3 4,3 44,8 39,8 36,1 32,7 3, 27,9 24,6 22, / /D237 1 x 9 7,3 73,6 67, 66,8 62,8 61,1 8,8 6,8 6,3 1,2 47,4 43,8 41,4 38, 34,8 32,2 27, 12-27/ /D23 1 x 11 88,2 8,4 79,2 79, 7,1 73, 71,2 69,2 68,8 63, 9,,7 3, 49,9 4,8 42,8 37,6 33, / /D266 1 x , 94,8 88,6 88,4 84,7 83,2 81,1 79,2 78,8 74, 7,3 66,8 64, 61,7 8,,4,7 46,8 4, Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. HHn = class of risk value referred to the required rated capacity (Tab.7 par EN1284) Inlet pressure drops must be deducted. Make sure these drops are less than 4,mt The values shown identify performance levels according to the reference standard EN1284. HH1n RISK CLASS 1284_1pg-st-fhf12-2p-en_b_th TABELLA DI PRESTAZIONI IDRAULICHE NPSHr EN1284 SERIE FHF12 2 poli Hz 1 POMPA DI SERVIZIO NPSH REQUIRED FOR PUMP SERIES FHF 12 RISK CLASS TYPE RATED HH6n HH7n HH8n HH9n HH1n HH6m HH7m HH8m HH9m HH1m FHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m 3 /h PUMP kw NPSHr [METRES COLUMN OF WATER] 12-2/3 12-2/D18 1 x 3 6, 6,8 8, 8, 9,1 9,3 9,6 9,9 9,9 1,4 12-2/4 12-2/D26 1 x 4 6,1 6,2 7,1 7,1 7,6 7,7 8, 8,3 8,3 8,9 9, 1, 1,4 12-2/ 12-2/D216 1 x 6,1 6,2 7,1 7,1 7,6 7,7 8, 8,3 8,3 8,9 9, 1, 1,4 1,8 11, 12-27/ /D224 1 x 7 7,8 8,3 8,3 8, 8,6 8,7 8,8 8,9 9,3 9,7 1,1 1, 11,1 11,9 12, / /D237 1 x 9 6, 6,9 6,9 7,2 7,3 7, 7,7 7,7 8,1 8,4 8,8 9, 9,4 9,9 1,4 11, / /D23 1 x 11 6, 6,9 6,9 7,2 7,3 7, 7,7 7,7 8,1 8,4 8,8 9, 9,4 9,9 1,4 11,4 12, 12-27/ /D266 1 x 132 6, 6,9 6,9 7,2 7,3 7, 7,7 7,7 8,1 8,4 8,8 9, 9,4 9,9 1,4 11,4 12, 14,8 The declared NPSH values were obtained in the laboratory and refer to a single service pump HHn, HHm = class of risk value referred to the required rated and maximum capacity (Tab.7 para EN1284) Check that NPSHd NPSHr+1m is satisfied at the maximum requested capacity 1284_1p-fhf12-2p_NPSHr-en_a_th 2
53 GEN..D/FHF 1-12 BOOSTER SETS TABELLA DATI ELETTRICI GRUPPI GEN..D/FHF 2 poli Hz ELECTRICAL DATA A TABLE AT Hz SERVICE PUMP ELECTRIC JOCKEY PUMP CURRENT (*) ABSORBED SET 3 X 4 V 1 x 23V 3x4 TYPE NOMINAL 1x23V 3x4V FHF.. POWER ELECTRIC Pn In TYPE Pn In In GEN..D GEN..1D GEN..1D GEN..11D PUMP PUMP kw A kw A A A A A A 32-12/ /D119,7 1,76 1SV 7,37 2,82 1,3 3,8 4,8 6, / /D136 1,1 2,36 1SV 8, 3,88 1,48 3 6,9,4 6, / /D1 1, 3,2 1SV 8, 3,88 1,48 3 6,9 6, 7, 32-16/ /D164 2,2 4,64 1SV 9, 3,88 1,48 3 6,9 7,6 9,1 32-2/3 32-2/D188 3,91 1SV 11, 3,88 1,48 3 6,9 8,9 1,4 32-2/4 32-2/D24 4 7, 1SV 12,7 4,88 1,76 3 7,9 1, 12,3 4-12/ /D112 1,1 2,36 1SV 7,37 2,82 1,3 3,8,4 6,7 4-12/1 4-12/D122 1, 3,2 1SV 8, 3,88 1,48 3 6,9 6, 7, 4-12/ /D143 2,2 4,64 1SV 8, 3,88 1,48 3 6,9 7,6 9,1 4-16/3 4-16/D19 3,91 1SV 9, 3,88 1,48 3 6,9 8,9 1,4 4-16/4 4-16/D , 1SV 1, 3,88 1,48 3 6,9 1, 12, 4-2/ 4-2/D19, 11, 1SV 11, 3,88 1,48 3 6,9 14, 1, 4-2/7 4-2/D29 7, 14,3 1SV 12,7 4,88 1,76 3 7,9 17,3 19,1 4-2/11A 4-2/D ,8 1SV 13,7 4,88 1,76 3 7,9 22,8 24,6 4-2/11 4-2/D ,8 1SV 1,7 4,88 1,76 3 7,9 22,8 24,6 4-2/1 4-2/D ,2 1SV 17 1,1 6,77 2,36 3 9,8 29,2 31,6-12/22-12/D119 2,2 4,64 1SV 7,37 2,82 1,3 3,8 7,6 9, -12/3-12/D13 3,91 1SV 8, 3,88 1,48 3 6,9 8,9 1,4-12/4-12/D , 1SV 8, 3,88 1,48 3 6,9 1, 12, -16/ -16/D18, 11, 1SV 9, 3,88 1,48 3 6,9 14, 1, -16/7-16/D174 7, 14,3 1SV 1, 3,88 1,48 3 6,9 17,3 18,8-2/11A -2/D ,8 1SV 12,7 4,88 1,76 3 7,9 22,8 24,6-2/11-2/D ,8 1SV 12,7 4,88 1,76 3 7,9 22,8 24,6-2/1-2/D ,2 1SV 1,7 4,88 1,76 3 7,9 29,2 31, -2/18-2/D237 18, 32,9 1SV 1,7 4,88 1,76 3 7,9 3,9 37,7-2/22-2/D ,1 1SV 17 1,1 6,77 2,36 3 9,8 42,1 44, 6-12/4 6-12/D , 1SV 7,37 2,82 1,3 3,8 1, 11,9 6-12/ 6-12/D129, 11, 1SV 8, 3,88 1,48 3 6,9 14, 1, 6-12/7 6-12/D14 7, 14,3 1SV 8, 3,88 1,48 3 6,9 17,3 18,8 6-16/11A 6-16/D ,8 1SV 9, 3,88 1,48 3 6,9 22,8 24,3 6-16/ /D ,8 1SV 1, 3,88 1,48 3 6,9 22,8 24,3 6-16/1 6-16/D ,2 1SV 1, 3,88 1,48 3 6,9 29,2 3,7 6-2/1 6-2/D ,2 1SV 11, 3,88 1,48 3 6,9 29,2 3,7 6-2/18 6-2/D198 18, 32,9 1SV 12,7 4,88 1,76 3 7,9 3,9 37,7 6-2/22 6-2/D ,1 1SV 12,7 4,88 1,76 3 7,9 42,1 43,9 6-2/22 6-2/D ,1 1SV 13,7 4,88 1,76 3 7,9 42,1 43,9 6-2/3 6-2/D ,6 1SV 1,7 4,88 1,76 3 7,9 6,6 8,4 6-2/37 6-2/D ,8 1SV 17 1,1 6,77 2,36 3 9,8 68,8 71,2 8-16/1 8-16/D ,2 1SV 9, 3,88 1,48 3 6,9 29,2 3,7 8-16/ /D173 18, 32,9 1SV 1, 3,88 1,48 3 6,9 3,9 37,4 8-2/22 8-2/D ,1 1SV 11, 3,88 1,48 3 6,9 42,1 43,6 8-2/3 8-2/D27 3 3,6 1SV 12,7 4,88 1,76 3 7,9 6,6 8,4 8-2/37 8-2/D ,8 1SV 1,7 4,88 1,76 3 7,9 68,8 7,6 8-2/4 8-2/D , 1SV 1,7 4,88 1,76 3 7,9 81, 82,8 8-2/ 8-2/D26 9, 1SV 17 1,1 6,77 2,36 3 9,8 98, 1,4 ENMTP-FHF_2p-en_d_te (*) The current indicated is the maximum current absorbed. At the set 3x4V three-phase power supply GEN..1D and GEN..11D to add the control panel current of the engine pump (GEN..D) 1x23V The sets GEN..1D have the electric jockey pump 1x23V single-phase power supply. GEN..D/FHF 3
54 GEN..D/FHF GEN..D/FHF 1-12 BOOSTER SETS TABELLA DATI ELETTRICI GRUPPI GEN..D/FHF 2 poli Hz ELECTRICAL DATA A TABLE AT Hz SERVICE PUMP ELECTRIC JOCKEY PUMP CURRENT (*) ABSORBED SET 3 X 4 V 1 x 23V 3x4 TYPE NOMINAL 1x23V 3x4V FHF.. POWER ELECTRIC Pn In TYPE Pn In In GEN..D GEN..1D GEN..1D GEN..11D PUMP PUMP kw A kw A A A A A A 1-16/ /D1 18, 32,9 1SV 8, 3,88 1,48 3 6,9 3,9 37,4 1-16/ /D ,1 1SV 9, 3,88 1,48 3 6,9 42,1 43,6 1-16/3 1-16/D18 3 3,6 1SV 11, 3,88 1,48 3 6,9 6,6 8,1 1-2/18 1-2/D168 18, 32,9 1SV 1, 3,88 1,48 3 6,9 3,9 37,4 1-2/3 1-2/D ,6 1SV 11, 3,88 1,48 3 6,9 6,6 8,1 1-2/37 1-2/D ,8 1SV 12,7 4,88 1,76 3 7,9 68,8 7,6 1-2/4 1-2/D , 1SV 13,7 4,88 1,76 3 7,9 81, 82,8 1-2/3 1-2/D2 3 3,6 1SV 12,7 4,88 1,76 3 7,9 6,6 8,4 1-2/4 1-2/D , 1SV 1,7 4,88 1,76 3 7,9 81, 82,8 1-2/ 1-2/D23 9, 1SV 1,7 4,88 1,76 3 7,9 98, 99,8 1-2/7 1-2/D , 1SV 17 1,1 6,77 2,36 3 9,8 132, 134,4 1-2/9 1-2/D , 1SV 19 1,1 6,77 2,36 3 9,8 17, 19,4 12-2/3 12-2/D18 3 3,6 1SV 9, 3,88 1,48 3 6,9 6,6 8,1 12-2/4 12-2/D , 1SV 11, 3,88 1,48 3 6,9 81, 82, 12-2/ 12-2/D216 9, 1SV 12,7 4,88 1,76 3 7,9 98, 99, / /D , 1SV 13,7 4,88 1,76 3 7,9 132, 133, / /D , 1SV 1,7 4,88 1,76 3 7,9 17, 18, / /D , 1SV 17 1,1 6,77 2,36 4, 11,3 192, 194, / /D , 1SV 19 1,1 6,77 2,36 4, 11,3 227, 229,9 ENMTP-FHF1-en_2p_d_te (*) The current indicated is the maximum current absorbed. At the set 3x4V three-phase power supply GEN..1D and GEN..11D to add the control panel current of the engine pump (GEN..D) 1x23V The sets GEN..1D have the electric jockey pump 1x23V single-phase power supply. 4
55 Fire-fighting booster sets EN 1284 MARKET SECTORS CIVIL, INDUSTRIAL APPLICATIONS Fixed fire-fighting systems. Automatic Sprinkler systems. DFHF Series GEN..D/FHF SPECIFICATIONS Flow up to 6 m 3 /h. Head up to 1 m. Panel supply power voltage: 1 x 23V ± 1%. Frequency: Hz. Diesel engine with battery start. Diesel engine service pump in horizontal design: - FHF series. Maximum running pressure: 12 bar. Voltage for controls outside panel: Vac. Protection grade: - electric panel: IP4. Electric pumps maximum power 132 kw.
56 DFHF 32-8 DIESEL ENGINE PUMP SERIES FIRE-FIGHTING EN 1284 GEN..D/FHF For the overall dimensions of the fuel tank and the starting batteries, see tables on pages
57 DFHF 32-8 DIESEL ENGINE PUMP SERIES FIRE-FIGHTING EN 1284 D.. DNA DNM A B C E F H H1 H2 FHFE32-12/D119 R 2" FHFE32-12/D136 R 2" FHFE32-16/D1 R 2" FHFE32-16/D164 R 2" FHFE32-2/D188 R 2" FHFE32-2/D24 R 2" FHFE4-12/D FHFE4-12/D FHFE4-12/D FHFE4-16/D FHFE4-16/D FHFE4-2/D FHFE4-2/D FHFE4-2/D FHFE4-2/D FHFE4-2/D FHFE-12/D FHFE-12/D FHFE-12/D FHFE-16/D FHFE-16/D FHFE-2/D FHFE-2/D FHFE-2/D FHFE-2/D FHFE-2/D FHFE6-12/D FHFE6-12/D FHFE6-12/D FHFE6-16/D FHFE6-16/D FHFE6-16/D FHFE6-2/D FHFE6-2/D FHFE6-2/D FHFE6-2/D FHFE6-2/D FHFE6-2/D FHFE8-16/D FHFE8-16/D FHFE8-2/D FHFE8-2/D FHFE8-2/D FHFE8-2/D FHFE8-2/D Dimensions in mm. Tolerance ± 1 mm. d_fhfe-en_h_td GEN..D/FHF 7
58 DFHF 1-12 DIESEL ENGINE PUMP SERIES FIRE-FIGHTING EN 1284 GEN..D/FHF For the overall dimensions of the fuel tank and the starting batteries, see tables on pages 2-2. D.. DNA DNM A B C E F H H1 H2 FHFE1-16/D FHFE1-16/D FHFE1-16/D FHFE1-2/D FHFE1-2/D FHFE1-2/D FHFE1-2/D FHFE1-2/D FHFE1-2/D FHFE1-2/D FHFE1-2/D FHFE1-2/D FHFE12-2/D FHFE12-2/D FHFE12-2/D FHFE12-27/D FHFE12-27/D FHFE12-27/D FHFE12-27/D Dimensions in mm. Tolerance ± 1 mm. d_fhfe1-en_e_td 8
59 Fire-fighting booster sets EN 1284 MARKET SECTORS CIVIL, INDUSTRIAL APPLICATIONS Fixed fire-fighting systems. Automatic Sprinkler systems. GEN..D/FHF Series GEN..D/FHF SPECIFICATIONS Flow up to 6 m 3 /h. Head up to 1 m. Panel supply power voltage: 1 x 23V ± 1%. Frequency: Hz. Voltage for controls outside panel: Vac. Diesel engine with battery start. Diesel engine service pump in horizontal design: - FHF series. Maximum running pressure: 12 bar. Protection grade: - electric panel: IP4. Electric pumps maximum power 132 kw. 9
60 GEN..D/FHF 32-8 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..D/FHF For the overall dimensions of the fuel tank and the starting batteries, see tables on pages
61 GEN..D/FHF 32-8 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..D DRW N DNA DNM A B D E G N P Q FHF32-12/D119 1 R 2" R 1"1/ FHF32-12/D136 1 R 2" R 1"1/ FHF32-16/D1 1 R 2" R 1"1/ FHF32-16/D164 1 R 2" R 1"1/ FHF32-2/D188 1 R 2" R 1"1/ FHF32-2/D24 1 R 2" R 1"1/ FHF4-12/D FHF4-12/D FHF4-12/D FHF4-16/D FHF4-16/D FHF4-2/D FHF4-2/D FHF4-2/D FHF4-2/D FHF4-2/D FHF-12/D FHF-12/D FHF-12/D FHF-16/D FHF-16/D FHF-2/D FHF-2/D FHF-2/D FHF-2/D FHF-2/D FHF6-12/D FHF6-12/D FHF6-12/D FHF6-16/D FHF6-16/D FHF6-16/D FHF6-2/D FHF6-2/D FHF6-2/D FHF6-2/D FHF6-2/D FHF6-2/D FHF8-16/D FHF8-16/D FHF8-2/D FHF8-2/D FHF8-2/D FHF8-2/D FHF8-2/D Dimensions in mm. Tolerance ± 1 mm. gend_fhf-en_h_td GEN..D/FHF 61
62 GEN..D/FHF 1-12 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..D/FHF For the overall dimensions of the fuel tank and the starting batteries, see tables on pages 2-2. GEN..D DRW N DNA DNM A B D E G N P Q FHF1-16/D FHF1-16/D FHF1-16/D FHF1-2/D FHF1-2/D FHF1-2/D FHF1-2/D FHF1-2/D FHF1-2/D FHF1-2/D FHF1-2/D FHF1-2/D FHF12-2/D FHF12-2/D FHF12-2/D FHF12-27/D FHF12-27/D FHF12-27/D FHF12-27/D Dimensions in mm. Tolerance ± 1 mm. gend_fhf1-en_f_td 62
63 Fire-fighting booster sets EN 1284 MARKET SECTORS CIVIL, INDUSTRIAL APPLICATIONS Fixed fire-fighting systems. Automatic Sprinkler systems. GEN..1D/FHF Series GEN..D/FHF SPECIFICATIONS Flow up to 6 m 3 /h. Head up to 1 m. Panel supply power voltage: - Electric pump: 1 x 23V ± 1%. - Diesel engine pump: 1 x 23V ± 1%. Frequency: Hz. Voltage for controls outside panel: Vac. Protection grade: - electric panel: IP4. Electric pumps maximum power 132 kw. Electric motor start : - Direct start for powers up to 22 kw included for electric pump. Diesel engine with battery start. Service pump in horizontal design: - FHF series. Electric jockey pump with vertical axis: - SV Series (motor protection grade IP). Maximum running pressure: 12 bar. 63
64 GEN..1D/FHF 32-8 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..D/FHF For the overall dimensions of the fuel tank and the starting batteries, see tables on pages
65 GEN..1D/FHF 32-8 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..1D DRW N DNA DNP DNM A A1 B C D F G H I L N P Q FHF32-12/D119 1 R 2" Rp 1" R 1"1/ FHF32-12/D136 1 R 2" Rp 1" R 1"1/ FHF32-16/D1 1 R 2" Rp 1" R 1"1/ FHF32-16/D164 1 R 2" Rp 1" R 1"1/ FHF32-2/D188 1 R 2" Rp 1" R 1"1/ FHF32-2/D24 1 R 2" Rp 1" R 1"1/ FHF4-12/D Rp 1" FHF4-12/D Rp 1" FHF4-12/D Rp 1" FHF4-16/D Rp 1" FHF4-16/D Rp 1" FHF4-2/D Rp 1" FHF4-2/D Rp 1" FHF4-2/D Rp 1" FHF4-2/D Rp 1" FHF4-2/D Rp 1" FHF-12/D Rp 1" FHF-12/D Rp 1" FHF-12/D Rp 1" FHF-16/D Rp 1" FHF-16/D Rp 1" FHF-2/D Rp 1" FHF-2/D Rp 1" FHF-2/D Rp 1" FHF-2/D Rp 1" FHF-2/D2 2 6 Rp 1" FHF6-12/D Rp 1" FHF6-12/D Rp 1" FHF6-12/D Rp 1" FHF6-16/D Rp 1" FHF6-16/D Rp 1" FHF6-16/D Rp 1" FHF6-2/D Rp 1" FHF6-2/D Rp 1" FHF6-2/D Rp 1" FHF6-2/D Rp 1" FHF6-2/D Rp 1" FHF6-2/D Rp 1" FHF8-16/D Rp 1" FHF8-16/D Rp 1" FHF8-2/D Rp 1" FHF8-2/D Rp 1" FHF8-2/D Rp 1" FHF8-2/D Rp 1" FHF8-2/D Rp 1" Dimensions in mm. Tolerance ± 1 mm. gen1d_fhf-en_g_td GEN..D/FHF 6
66 GEN..1D/FHF 1-12 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..D/FHF For the overall dimensions of the fuel tank and the starting batteries, see tables on pages
67 GEN..1D/FHF 1-12 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..1D DRW N DNA DNP DNM A A1 B C D F G H I L N P Q FHF1-16/D Rp 1" FHF1-16/D Rp 1" FHF1-16/D Rp 1" FHF1-2/D Rp 1" FHF1-2/D Rp 1" FHF1-2/D Rp 1" FHF1-2/D Rp 1" FHF1-2/D Rp 1" FHF1-2/D Rp 1" FHF1-2/D Rp 1" FHF1-2/D Rp 1" \ FHF1-2/D Rp 1" \ FHF12-2/D Rp 1" FHF12-2/D Rp 1" FHF12-2/D Rp 1" FHF12-27/D Rp 1" \ FHF12-27/D Rp 1" \ FHF12-27/D Rp 1" \ FHF12-27/D Rp 1" \ Dimensions in mm. Tolerance ± 1 mm. gen1d_fhf1-en_f_td GEN..D/FHF 67
68 GEN..D/FHF 68
69 Fire-fighting booster sets EN 1284 MARKET SECTORS CIVIL, INDUSTRIAL APPLICATIONS Fixed fire-fighting systems. Automatic Sprinkler systems. GEN..1D/FHF Series GEN..D/FHF SPECIFICATIONS Flow up to 13 m 3 /h. Head up to 1 m. Panel supply power voltage: - Electric pump: 3 x 4V ± 1%. - Diesel engine pump: 1 x 23V ± 1%. Frequency: Hz. Voltage for controls outside panel: Vac. Protection grade: - electric panel: IP4. Electric motor start : - Direct start for powers up to 22 kw included for pump (GEND...). - Star/delta start for higher powers (GENY... set). Diesel engine with battery start. Service pump in horizontal design: - FHF series (IP electric motor protection). Maximum running pressure: 12 bar. Electric pumps maximum power 132 kw. 69
70 GEN..1D/FHF 32-8 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..D/FHF For the overall dimensions of the fuel tank and the starting batteries, see tables on pages
71 GEN..1D/FHF 32-8 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..1D DRW N DNA DNM A A1 B C D G H I L N P Q FHF32-12/7/D119 1 R 2" R 2" FHF32-12/11/D136 1 R 2" R 2" FHF32-16/1/D1 1 R 2" R 2" FHF32-16/22/D164 1 R 2" R 2" FHF32-2/3/D188 1 R 2" R 2" FHF32-2/4/D24 1 R 2" R 2" FHF4-12/11/D FHF4-12/1/D FHF4-12/22/D FHF4-16/3/D FHF4-16/4/D FHF4-2//D FHF4-2/7/D FHF4-2/11A/D FHF4-2/11/D FHF4-2/1/D FHF-12/22/D FHF-12/3/D FHF-12/4/D FHF-16//D FHF-16/7/D FHF-2/11A/D FHF-2/11/D FHF-2/1/D FHF-2/18/D FHF-2/22/D FHF6-12/4/D FHF6-12//D FHF6-12/7/D FHF6-16/11A/D FHF6-16/11/D FHF6-16/1/D FHF6-2/1/D FHF6-2/18/D FHF6-2/22/D FHF6-2/22/D FHF6-2/3/D FHF6-2/37/D FHF8-16/1/D FHF8-16/18/D FHF8-2/22/D FHF8-2/3/D FHF8-2/37/D FHF8-2/4/D FHF8-2//D Dimensions in mm. Tolerance ± 1 mm. gen1d_fhf-en_g_td GEN..D/FHF 71
72 GEN..D/FHF 72
73 Fire-fighting booster sets EN 1284 MARKET SECTORS CIVIL, INDUSTRIAL APPLICATIONS Fixed fire-fighting systems. Automatic Sprinkler systems. GEN..11D/FHF Series GEN..D/FHF SPECIFICATIONS Flow up to 13 m 3 /h. Head up to 1 m. Panel supply power voltage: - Electric pump: 3 x 4V ± 1%. - Diesel engine pump: 1 x 23V ± 1%. Frequency: Hz. Voltage for controls outside panel: Vac. Protection grade: - electric panel: IP4. Electric pumps maximum power 132 kw. Electric motor start : - Direct start for powers up to 22 kw included for pump (GEND...). - Star/delta start for higher powers (GENY... set). Diesel engine with battery start. Service pump in horizontal design: - FHF series (IP electric motor protection). Electric jockey pump with vertical axis: - SV Series (motor protection grade IP). Maximum running pressure: 12 bar. 73
74 GEN..11D/FHF 32-8 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..D/FHF For the overall dimensions of the fuel tank and the starting batteries, see tables on pages
75 GEN..11D/FHF 32-8 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..11D DRW DNA DNP DNM A A1 B C D F G H I I1 L N P Q N FHF32-12/7/D119 1 R 2" Rp 1" R 2" FHF32-12/11/D136 1 R 2" Rp 1" R 2" FHF32-16/1/D1 1 R 2" Rp 1" R 2" FHF32-16/22/D164 1 R 2" Rp 1" R 2" FHF32-2/3/D188 1 R 2" Rp 1" R 2" FHF32-2/4/D24 1 R 2" Rp 1" R 2" FHF4-12/11/D Rp 1" FHF4-12/1/D Rp 1" FHF4-12/22/D Rp 1" FHF4-16/3/D Rp 1" FHF4-16/4/D Rp 1" FHF4-2//D Rp 1" FHF4-2/7/D Rp 1" FHF4-2/11A/D Rp 1" FHF4-2/11/D Rp 1" FHF4-2/1/D Rp 1" FHF-12/22/D Rp 1" FHF-12/3/D Rp 1" FHF-12/4/D Rp 1" FHF-16//D Rp 1" FHF-16/7/D Rp 1" FHF-2/11A/D Rp 1" FHF-2/11/D Rp 1" FHF-2/1/D Rp 1" FHF-2/18/D Rp 1" FHF-2/22/D2 2 6 Rp 1" FHF6-12/4/D Rp 1" FHF6-12//D Rp 1" FHF6-12/7/D Rp 1" FHF6-16/11A/D Rp 1" FHF6-16/11/D Rp 1" FHF6-16/1/D Rp 1" FHF6-2/1/D Rp 1" FHF6-2/18/D Rp 1" FHF6-2/22/D Rp 1" FHF6-2/22/D Rp 1" FHF6-2/3/D Rp 1" FHF6-2/37/D Rp 1" FHF8-16/1/D Rp 1" FHF8-16/18/D Rp 1" FHF8-2/22/D Rp 1" FHF8-2/3/D Rp 1" FHF8-2/37/D Rp 1" FHF8-2/4/D Rp 1" FHF8-2//D Rp 1" Dimensions in mm. Tolerance ± 1 mm. gen11d_fhf-en_g_td GEN..D/FHF 7
76 GEN..11D/FHF 1-12 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..D/FHF For the overall dimensions of the fuel tank and the starting batteries, see tables on pages
77 GEN..11D/FHF 1-12 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..11D DRW DNA DNP DNM A A1 B C D F G H I I1 L N P Q N FHF1-16/18/D Rp 1" FHF1-16/22/D Rp 1" FHF1-16/3/D Rp 1" FHF1-2/18/D Rp 1" FHF1-2/3/D Rp 1" FHF1-2/37/D Rp 1" FHF1-2/4/D Rp 1" FHF1-2/3/D Rp 1" FHF1-2/4/D Rp 1" FHF1-2//D Rp 1" FHF1-2/7/D Rp 1" \ FHF1-2/9/D Rp 1" \ FHF12-2/3/D Rp 1" FHF12-2/4/D Rp 1" FHF12-2//D Rp 1" FHF12-27/7/D Rp 1" \ FHF12-27/9/D Rp 1" \ FHF12-27/11/D Rp 1" \ FHF12-27/132/D Rp 1" \ Dimensions in mm. Tolerance ± 1 mm. gen11d_fhf1-en_f_td GEN..D/FHF 77
78 GEN..D/FHF 78
79 GEN..D/FHF SERIES OF BOOSTER SETS (POSITIVE SUCTION HEAD) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT FH [rpm] ISO Annex A FH [rpm] ISO Annex A Q [Imp gpm] Q 1 [Imp gpm] Q [US gpm],2,8 Hc [m] H [ft],2, Q [US gpm],2,8 Hc [m] H [ft],2,6,1,1,4,1,1,4,,2,,2, 6,, 1, 3 NPSHr [m] NPSHr [ft] NPSHr [m] NPSHr [ft] GEN..D/FHF Q [m 3 /h] Q [l/min] 76474_A_CH Q [m 3 /h] Q [l/min] 7647_A_CH FH [rpm] ISO Annex A FH [rpm] ISO Annex A Q 12 [Imp gpm] Q [Imp gpm] Q [US gpm], Q [US 2gpm], Hc [m],4 1, H [ft] Hc [m],4 1, H [ft],3 1,,3 1,,2,2,,,1,1, 1,, 1, NPSHr [m] 4 1 NPSHr [ft] NPSHr [m] 2 NPSHr [ft] Q [m 3 /h] Q [l/min] 76476_A_CH Q [m 3 /h] Q 1 [l/min] 76477_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 79
80 GEN..D/FHF SERIES OF BOOSTER SETS (POSITIVE SUCTION HEAD) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT FH [rpm] ISO Annex A FH [rpm] ISO Annex A Q [Imp gpm] Q [Imp gpm] Q [US 2gpm], Q [US 2gpm],6 Hc [m],4 1, H [ft] Hc [m], 1, H [ft],3 1,,4,3 1,,2,1,,2,1,, 1,, 1, GEN..D/FHF NPSHr [m] NPSHr [ft] NPSHr [m] NPSHr [ft] Q [m 3 /h] Q 1 [l/min] 76478_A_CH Q [m 3 /h] Q 1 [l/min] 7646_A_CH FH [rpm] ISO Annex A FH [rpm] ISO Annex A Q [Imp gpm] Q [Imp gpm] Q [US 2gpm], , Q [US gpm] Hc [m], 1, H [ft] Hc [m],4 1, H [ft],4,3 1,,3 1,,2,2,1,,1,, 1,, 1, NPSHr [m] 2 NPSHr [ft] NPSHr [m] 2 NPSHr [ft] Q [m 3 /h] Q 1 [l/min] 7647_A_CH Q [m 3 1 /h] Q [l/min] 76481_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 8
81 GEN..D/FHF SERIES OF BOOSTER SETS (POSITIVE SUCTION HEAD) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT FH [rpm] ISO Annex A FH [rpm] ISO Annex A Q [Imp gpm] Q [Imp gpm] , Q [US gpm] Q [US gpm], Hc [m],4 1, H [ft] Hc [m],4 1, H [ft],3 1,,3 1,,2,2,,,1,1, 1,, 1, NPSHr [m] NPSHr [ft] NPSHr [m] NPSHr [ft] GEN..D/FHF Q [m1 3 /h] Q 16 [l/min] 76482_A_CH Q [m12 3 /h] 1 1 Q [l/min] _A_CH FH [rpm] ISO Annex A FH [rpm] ISO Annex A Q [Imp gpm] Q [Imp gpm] Q [US gpm], Q [US 6 gpm],6 Hc [m], H [ft] Hc [m], H [ft] 1, 1,,4,4,3 1,,3 1,,2,2,,,1,1, 1,, 1, NPSHr [m] 2 NPSHr [ft] NPSHr [m] 2 NPSHr [ft] Q [m12 3 /h] 1 1 Q [l/min] _A_CH Q [m14 3 /h] Q [l/min] 7648_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 81
82 GEN..D/FHF SERIES OF BOOSTER SETS (POSITIVE SUCTION HEAD) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT FH [rpm] ISO Annex A FH [rpm] ISO Annex A Q [Imp gpm] Q [Imp gpm] Q [US 7 gpm], Q [US 7 gpm],6 Hc [m], H [ft] Hc [m], H [ft] 1, 1,,4,4,3 1,,3 1,,2,2,,,1,1, 1,, 1, GEN..D/FHF NPSHr [m] /11A φ /1 Ø /1 φ /11 φ NPSHr [ft] NPSHr [m] 1 6-2/1 φ /1 Ø /22 φ /18 φ NPSHr [ft] Q [m16 3 /h] Q [l/min] 76486_A_CH Q [m16 3 /h] Q [l/min] 76487_A_CH FH [rpm] ISO Annex A FH [rpm] ISO Annex A Q [Imp gpm] Q [Imp gpm] Q [US 7 gpm], , Q [US gpm] Hc [m], 1, H [ft] Hc [m],4 1, H [ft],4,3 1,,3 1,,2,2,1,,1,, 1,, 1, NPSHr [m] 6-16/1 Ø NPSHr [ft] NPSHr [m] 6-16/1 Ø NPSHr [ft] Q [m16 3 /h] Q [l/min] 76488_A_CH Q [m2 3 /h] Q 4 [l/min] 76489_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 82
83 GEN..D/FHF SERIES OF BOOSTER SETS (POSITIVE SUCTION HEAD) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT FH [rpm] ISO Annex A FH [rpm] ISO Annex A Q [Imp gpm] Q [Imp gpm] , Q [US gpm] , Q [US gpm] Hc [m],4 1, H [ft] Hc [m],4 1, H [ft],3 1,,3 1,,2,2,,,1,1, 1,, 1, NPSHr [m] /1 Ø NPSHr [ft] NPSHr [m] 1 8-2/37 φ /1 Ø / φ /4 φ NPSHr [ft] GEN..D/FHF Q [m2 3 /h] Q 4 [l/min] 7649_A_CH Q [m2 3 /h] Q 4 [l/min] 76491_A_CH FH [rpm] ISO Annex A FH [rpm] ISO Annex A Q 14 [Imp gpm] Q 14 [Imp gpm] ,2 Q [US gpm], ,2 Q [US gpm],8 Hc [m],2 H [ft] Hc [m],2 H [ft],6,6,1,1,4,4,1,1,,2,,2, 1,, 1, 1-16/18 φ 13/ /18 φ 141/ NPSHr [m] 1-16/3 φ /22 φ 19/ /1 Ø NPSHr [ft] NPSHr [m] 6-16/1 Ø /4 φ /37 φ 23 2 NPSHr [ft] 1-2/3 φ 189/ Q [m4 3 /h] Q [l/min] 76492_A_CH Q [m4 3 /h] Q [l/min] 76493_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 83
84 GEN..D/FHF SERIES OF BOOSTER SETS (POSITIVE SUCTION HEAD) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT FH [rpm] ISO Annex A FH [rpm] ISO Annex A 1 1 Q [Imp gpm] Q 2 [Imp gpm] Hc [m] 1 1,2,2 Q [US gpm],8,6 H [ft] Q 3 [US gpm],2,8 Hc [m] H [ft],2,6,1,1,4,1,1,4,,2,,2, 1,, 1, 12-2/3 φ 162/194 GEN..D/FHF NPSHr [m] 1 1-2/3 φ /1 Ø /9 φ /7 φ / φ /4 φ NPSHr [ft] NPSHr [m] / φ /4 φ /1 Ø NPSHr [ft] Q [m 3 /h] Q [l/min] 76494_A_CH Q [m7 3 /h] Q [l/min] 7649_A_CH FH [rpm] ISO Annex A Q [Imp gpm] Q [US 3gpm],2,8 Hc [m] H [ft],2,6,1,1,4,,2, 2, /7 φ 216/23 4 NPSHr [m] /132 φ / /11 φ 23 Ø /9 φ NPSHr [ft] Q [m8 3 /h] Q [l/min] 76496_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 84
85 GEN..D/FHF SERIES OF BOOSTER SETS (SUCTION LIFT) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT FH [rpm] ISO Annex A FH [rpm] ISO Annex A Q [Imp gpm] Q [US gpm], Q 1 [Imp gpm] Q [US gpm],6 Hc [m],4 1, H [ft] Hc [m], 1, H [ft],3 1,,4,3 1,,2,1,,2,1,, 6,, 1, 3 NPSHr [m] NPSHr [ft] NPSHr [m] NPSHr [ft] GEN..D/FHF Q [m 3 /h] Q [l/min] 7641_A_CH Q [m 3 /h] Q [l/min] 7642_A_CH FH [rpm] ISO Annex A FH [rpm] ISO Annex A Q 12 [Imp gpm] Q [Imp gpm] Q [US gpm], Q [US 2gpm],6 Hc [m], H [ft] Hc [m], H [ft] 1, 1,,4,4,3 1,,3 1,,2,2,,,1,1, 1,, 1, NPSHr [m] 4 1 NPSHr [ft] NPSHr [m] 2 NPSHr [ft] Q [m 3 /h] Q [l/min] 7643_A_CH Q [m 3 /h] Q 1 [l/min] 7644_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 8
86 GEN..D/FHF SERIES OF BOOSTER SETS (SUCTION LIFT) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT FH [rpm] ISO Annex A FH [rpm] ISO Annex A Q [Imp gpm] Q [Imp gpm] Q [US 2gpm], Q [US 2gpm],6 Hc [m], H [ft] Hc [m], H [ft] 1, 1,,4,4,3 1,,3 1,,2,2,,,1,1, 1,, 1, GEN..D/FHF NPSHr [m] NPSHr [ft] NPSHr [m] NPSHr [ft] Q [m 3 /h] Q 1 [l/min] 764_A_CH Q [m 3 /h] Q 1 [l/min] 7646_A_CH FH [rpm] ISO Annex A FH [rpm] ISO Annex A Q [Imp gpm] Q [Imp gpm] Q [US 2gpm], ,6 Q [US gpm] Hc [m], H [ft] Hc [m], H [ft] 1, 1,,4,4,3 1,,3 1,,2,2,,,1,1, 1,, 1, NPSHr [m] 2 NPSHr [ft] NPSHr [m] 2 NPSHr [ft] Q [m 3 /h] Q 1 [l/min] 7647_A_CH Q [m1 3 /h] Q [l/min] 7648_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 86
87 GEN..D/FHF SERIES OF BOOSTER SETS (SUCTION LIFT) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT FH [rpm] ISO Annex A FH [rpm] ISO Annex A Q [Imp gpm] Q [Imp gpm] ,6 Q [US gpm] Q [US gpm],6 Hc [m], H [ft] Hc [m], H [ft] 1, 1,,4,4,3 1,,3 1,,2,2,,,1,1, 1,, 1, NPSHr [m] NPSHr [ft] NPSHr [m] NPSHr [ft] GEN..D/FHF Q [m1 3 /h] Q 16 [l/min] 7649_A_CH Q [m12 3 /h] 1 1 Q [l/min] _A_CH FH [rpm] ISO Annex A FH [rpm] ISO Annex A Q [Imp gpm] Q [Imp gpm] Q [US gpm], Q [US 6 gpm],6 Hc [m], H [ft] Hc [m], H [ft] 1, 1,,4,4,3 1,,3 1,,2,2,,,1,1, 1,, 1, NPSHr [m] 2 NPSHr [ft] NPSHr [m] 2 NPSHr [ft] Q [m12 3 /h] 1 1 Q [l/min] _A_CH Q [m14 3 /h] Q [l/min] 76461_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 87
88 GEN..D/FHF SERIES OF BOOSTER SETS (SUCTION LIFT) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT FH [rpm] ISO Annex A FH [rpm] ISO Annex A Q [Imp gpm] Q [Imp gpm] Q [US 7 gpm], Q [US 7 gpm],6 Hc [m], H [ft] Hc [m], H [ft] 1, 1,,4,4,3 1,,3 1,,2,2,,,1,1, 1,, 1, GEN..D/FHF NPSHr [m] /11A φ /1 Ø /1 φ /11 φ NPSHr [ft] NPSHr [m] 1 6-2/1 φ /1 Ø /22 φ /18 φ NPSHr [ft] Q [m16 3 /h] Q [l/min] 76462_A_CH Q [m16 3 /h] Q [l/min] 76463_A_CH FH [rpm] ISO Annex A FH [rpm] ISO Annex A Q [Imp gpm] Q [Imp gpm] Q [US 7 gpm], ,6 Q [US gpm] Hc [m], H [ft] Hc [m], H [ft] 1, 1,,4,4,3 1,,3 1,,2,2,,,1,1, 1,, 1, NPSHr [m] 6-16/1 Ø NPSHr [ft] NPSHr [m] 6-16/1 Ø NPSHr [ft] Q [m16 3 /h] Q [l/min] 76464_A_CH Q [m2 3 /h] Q 4 [l/min] 7646_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 88
89 GEN..D/FHF SERIES OF BOOSTER SETS (SUCTION LIFT) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT FH [rpm] ISO Annex A FH [rpm] ISO Annex A Q [Imp gpm] Q [Imp gpm] ,6 Q [US gpm] ,6 Q [US gpm] Hc [m], H [ft] Hc [m], H [ft] 1, 1,,4,4,3 1,,3 1,,2,2,,,1,1, 1,, 1, NPSHr [m] /1 Ø NPSHr [ft] NPSHr [m] 1 8-2/37 φ /1 Ø / φ /4 φ NPSHr [ft] GEN..D/FHF Q [m2 3 /h] Q 4 [l/min] 76466_A_CH Q [m2 3 /h] Q 4 [l/min] 76467_A_CH FH [rpm] ISO Annex A FH [rpm] ISO Annex A Q 14 [Imp gpm] Q 14 [Imp gpm] ,2 Q [US gpm], ,2 Q [US gpm],8 Hc [m],2 H [ft] Hc [m],2 H [ft],6,6,1,1,4,4,1,1,,2,,2, 1,, 1, 1-16/18 φ 13/ /18 φ 141/ NPSHr [m] 1-16/3 φ /22 φ 19/ /1 Ø NPSHr [ft] NPSHr [m] 6-16/1 Ø /4 φ /37 φ 23 2 NPSHr [ft] 1-2/3 φ 189/ Q [m4 3 /h] Q [l/min] 76468_A_CH Q [m4 3 /h] Q [l/min] 76469_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 89
90 GEN..D/FHF SERIES OF BOOSTER SETS (SUCTION LIFT) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT FH [rpm] ISO Annex A FH [rpm] ISO Annex A 1 1 Q [Imp gpm] Q 2 [Imp gpm] Hc [m] 1 1,2,2 Q [US gpm],8,6 H [ft] Q 3 [US gpm],2,8 Hc [m] H [ft],2,6,1,1,4,1,1,4,,2,,2, 1,, 1, 12-2/3 φ 162/194 GEN..D/FHF NPSHr [m] 1 1-2/3 φ /1 Ø /9 φ /7 φ / φ /4 φ NPSHr [ft] NPSHr [m] / φ /4 φ /1 Ø NPSHr [ft] Q [m 3 /h] Q [l/min] 7647_A_CH Q [m7 3 /h] Q [l/min] 76471_A_CH FH [rpm] ISO Annex A Q [Imp gpm] Q [US 3gpm],2,8 Hc [m] H [ft],2,6,1,1,4,,2, 2, /7 φ 216/23 4 NPSHr [m] /132 φ / /11 φ 23 Ø /9 φ NPSHr [ft] Q [m8 3 /h] Q [l/min] 76472_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 9
91 GEN..D/SHF Series Fire-fighting booster sets EN 1284, electric pumps SHF series with high efficiency motors and diesel engine pumps Hz GEN..D/SHF 91
92 GEN..D/SHF 92
93 RANGE GEN..D/SHF RANGE The range of EN 1284 fire-fighting booster sets with diesel and electric service pumps and optional jockey pump to adapt to the specific needs of every application. D.. DIESEL ENGINE PUMP Single fire-fighting centrifugal pump in horizontal design with stainless steel casing, SHF series. Head up to 1 m. Flow up to 22 m 3 /h. GEN..D SERIES Fire-fighting sets with diesel engine centrifugal service pump, in horizontal design with stainless steel casing, SHF series. Head up to 1 m. Flow up to 22 m 3 /h. GEN..1D SERIES Fire-fighting sets with diesel engine service pump and electric jockey pump. The centrifugal service pump has horizontal design and stainless steel casing. SHF series. Head up to 1 m. Flow up to 22 m 3 /h. GEN..D/SHF GEN..1D SERIES Fire-fighting sets with diesel engine centrifugal service pump. The centrifugal service pump has horizontal design and stainless steel casing. SHF series. Head up to 1 m. Flow up to 44 m 3 /h. GEN..11D SERIES Fire-fighting sets with diesel engine service pump, electric service pump and electric jockey pump. The centrifugal service pump has horizontal design and stainless steel casing. SHF series. Head up to 1 m. Flow up to 44 m 3 /h. 93
94 GEN..D/SHF BOOSTER SETS SERIES HYDRAULIC TABELLA DI PRESTAZIONI PERFORMANCE IDRAULICHE TABLE SERIE AT 1SV 3SV HZ SV (JOCKEY 2p Hz PUMP) PUMP TYPE NOMINAL POWER l/min 12 2 Q = DELIVERY m 3 /h,7 1,2 1, 1,8 2,1 2,4 kw HP H = TOTAL HEAD METRES COLUMN OF WATER 1SV 2,37, 12,2 12,2 11, 1,7 9, 7,9 6, 1SV 3,37, 18, 18, 17, 1,7 13,8 11,4 8,4 1SV 4,37, 23,7 23, 22,1 2,4 17,9 14,6 1,6 1SV,37, 29,3 28,9 27, 24,8 21,6 17,4 12, 1SV 6,37, 34,8 34,2 31,7 28,9 2, 2, 14, 1SV 7,37, 4,2 39,2 36,1 32,7 28,1 22,2 1,2 1SV 8,,7 48,1 47,9 4,2 41,8 36,8 3,4 22,4 1SV 9,,7 3,7 3,4,4 46,4 4,8 33, 24,6 1SV 1,,7 9,4 9,, 1, 44,7 36,6 26,6 1SV 11,,7 6,1 64, 6,4, 48, 39, 28, 1SV 12,7 1 73,3 73,1 69,3 64,3 7,1 47,6 3,7 1SV 13,7 1 79,2 78,9 74,8 69,4 61,6 1,2 38,2 1SV 1,7 1 9,9 9, 8,6 79,3 7,1 8,1 43,1 1SV 17 1,1 1, 1,2 14,9 1, 93,1 82,6 68,6 1,2 1SV 19 1,1 1, 117, 116,7 111, 13,2 91, 7,8 6,3 1SV 22 1,1 1, 134,6 134,1 127,4 118,1 14,4 86,1 63, 1SV 2 1, 2 12,6 12,4 14, 13,4 12, 99,1 72,7 Prestazioni conformi alle norme ISO Annex A. EN1284_pp_1sv-2p-en_a_th GEN..D/SHF 94
95 GEN..D/SHF BOOSTER SETS SERIES SERVICE TABELLA ABBINAMENTI PUMP JOCKEY POMPA SERVIZIO PUMP COMBINATIONS SH POMPA PILOTA GRUPPI GEN 1 SERVICE PUMP JOCKEY PUMP ELECTRIC PUMP TYPE SHF PUMP 1SV / /D / /D / /D / /D /3 32-2/D /4 32-2/D / 32-2/D /7 32-2/D / /D / /D /1 4-12/D / /D /3 4-16/D /4 4-16/D / 4-2/D19 4-2/7 4-2/D29 4-2/11A 4-2/D /11 4-2/D /1 4-2/D21-12/22-12/D119-12/3-12/D13-12/4-12/D139-16/ -16/D18-16/7-16/D174-2/11A -2/D197-2/11-2/D29-2/1-2/D224-2/18-2/D237-2/22-2/D2 6-16/4 6-16/D / 6-16/D /7 6-16/D /11A 6-16/D / /D /1 6-2/D /18 6-2/D23 6-2/22 6-2/D21 6-2/3 6-2/D24 6-2/37 6-2/D2 8-16/ /D /1 8-16/D / /D /22 8-2/D /3 8-2/D21 8-2/37 8-2/D /4 8-2/D / 8-2/D22 8-2/7 8-2/D27 1SV 8 1SV 9 1SV 1 1SV 11 1SV 12 1SV 13 1SV 1 1SV 17 1SV SHF_ap-en_b_tc GEN..D/SHF 9
96 HYDRAULIC PERFORMANCE TABLE AT HZ (POSITIVE SUCTION HEAD) TABELLA DI PRESTAZIONI IDRAULICHE NETTE GRUPPI EN1284 SERIE SHF32 2 poli Hz 1 POMPA DI SERVIZIO, ASP ESCLUSA SOPRABATT GEN..D/SHF 32 BOOSTER SETS SERIES RISK CLASS TYPE RATED LHn SHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m 3 /h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 32-12/ /D121 1 x,7 16,7 14, 12,9 12,1 11, 7,6,1 3,7 1, / /D136 1 x 1,1 21,6 19, 17,9 17, 1,9 12,3 9,6 8,1 6, / /D1 1 x 1, 27,6 24,2 22,9 21,8 2, 16,3 13, 11,3 9, / /D168 1 x 2,2 3, 32, 3,9 29,9 28,7 24,7 21, 19,7 17, 16,1 1,2 13,1 32-2/3 32-2/D188 1 x 3 43,8 38,1 36,4 3,1 33,4 28, 23,9 21,6 18,8 17,1 32-2/4 32-2/D24 1 x 4 3,6 48,6 47,1 4,9 44,4 39,3 3,1 32,8 29,9 28,1 27, 24,1 32-2/ 32-2/D222 1 x, 61,7 6,3 4,6 3,2 1,6 46, 41,7 39,3 36,4 32-2/7 32-2/D242 1 x 7, 74,1 68,4 66,7 6,3 63,6 8,1 3,8 1,4 48,6 46,9 4,8 32-2/ /D26 1 x 11 86,3 79,8 77,9 76, 74,7 69, 64,7 62,3 9, 7,8 6,7 4, Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-sp-shf32-2p-en_a_th LHn = risk class value referred to the required rated capacity (Tab.6 para EN1284) Inlet pressure drops must be deducted. Make sure that these drops, added to the difference in level (max. 3.2m), are less than 4.m The values shown identify performance levels according to the reference standard EN1284. HYDRAULIC PERFORMANCE TABLE AT HZ (SUCTION LIFT) GEN..D/SHF 32 BOOSTER SETS SERIES TABELLA DI PRESTAZIONI IDRAULICHE NETTE GRUPPI EN1284 SERIE SHF32 2 poli Hz 1 POMPA DI SERVIZIO, ASP ESCLUSA SOTTOBATT RISK CLASS GEN..D/SHF TYPE RATED SHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m 3 /h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 32-12/ /D121 1 x,7 16,7 14, 12,9 12,1 11, 7,6,1 3,7 1, / /D136 1 x 1,1 21,6 19, 17,9 17, 1,9 12,3 9,6 8,1 6, / /D1 1 x 1, 27,6 24,2 22,9 21,8 2, 16,3 13, 11,3 9, / /D168 1 x 2,2 3, 32, 3,9 29,9 28,7 24,7 21, 19,7 17, 16,1 1,2 13,1 32-2/3 32-2/D188 1 x 3 43,8 38,1 36,4 3,1 33,4 28, 23,9 21,6 18,8 17,1 32-2/4 32-2/D24 1 x 4 3,6 48,6 47,1 4,9 44,4 39,3 3,1 32,8 29,9 28,1 27, 24,1 32-2/ 32-2/D222 1 x, 61,7 6,3 4,6 3,2 1,6 46, 41,7 39,3 36,4 32-2/7 32-2/D242 1 x 7, 74,1 68,4 66,7 6,3 63,6 8,1 3,8 1,4 48,6 46,9 4,8 32-2/ /D26 1 x 11 86,3 79,8 77,9 76, 74,7 69, 64,7 62,3 9, 7,8 6,7 4, Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-st-shf32-2p-en_a_th LHn = risk class value referred to the required rated capacity (Tab.6 para EN1284). Inlet pressure drops must be deducted. Make sure these drops are less than 4.m The values shown identify performance levels according to the reference standard EN1284. LHn 96
97 NPSH REQUIRED FOR PUMP SERIES SHF 32 TABELLA DI PRESTAZIONI IDRAULICHE NPSHr GRUPPI EN1284 SERIE SHF32 2 poli Hz RISK CLASS TYPE RATED GEN..D/SHF LHn SHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m 3 /h PUMP kw NPSHr [METRES COLUMN OF WATER] 32-12/ /D121 1 x,7 1, 1, 1,1 1,2 1,6 2,1 2,3 2, / /D136 1 x 1,1 1, 1, 1,1 1,2 1,6 2,1 2,3 2, / /D1 1 x 1, 1, 1,6 1,7 1,9 2, 3, 3,2 3, 32-16/ /D168 1 x 2,2 1,2 1,4 1, 1,6 2,2 2,8 3,3 3,8 4,2 4,4,2 32-2/3 32-2/D188 1 x 3 1,7 1,8 1,9 2,1 2,8 3,7 4,3,2,8 32-2/4 32-2/D24 1 x 4 1,6 1,8 2, 2,2 2,8 3,4 3,9 4,6,1, 6,9 32-2/ 32-2/D222 1 x, 2,8 3,2 3, 3,8,1 6,2 6,9 7,7 32-2/7 32-2/D242 1 x 7, 2,7 3, 3,2 3, 4,,3,8 6,3 6,6 6,9 32-2/ /D26 1 x 11 2,7 3, 3,2 3, 4,,3,8 6,3 6,6 6,9 7, The declared NPSH values were obtained in the laboratory and refer to a single service pump 1284_1p-shf32-2p_NPSHr-en_a_th LHn = risk class value referred to the required rated capacity (Tab.6 para EN1284) Check that NPSHd NPSHr+1m is satisfied 97
98 HYDRAULIC PERFORMANCE TABLE AT HZ (POSITIVE SUCTION HEAD) TABELLA DI PRESTAZIONI IDRAULICHE NETTE GRUPPI EN1284 SERIE SHF4 2 poli Hz 1 POMPA DI SERVIZIO, ASP ESCLUSA, INST SOPRA GEN..D/SHF 4 BOOSTER SETS SERIES RISK CLASS TYPE RATED OH1n SHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 4-12/ /D112 1 x 1,1 13,9 11,3 1, 9,3 3,4,7 4-12/1 4-12/D126 1 x 1, 18, 1,3 14, 13,3 7,4 4,7 4-12/ /D143 1 x 2,2 2,3 21,8 2, 19,8 14, 11,4 6,4, 3,6,6 4-16/3 4-16/D19 1 x 3 31,6 28,1 26,8 26, 19, 16, 1,8 9,2 7,6 4-16/4 4-16/D171 1 x 4 38,3 3,1 33,7 32,9 26, 23,6 18,1 16, 1, 11,7 4-2/ 4-2/D19 1 x, 46,4 42,7 41,2 4,4 33,1 29,7 23,3 21, 19,6 4-2/7 4-2/D29 1 x 7, 7, 3,1 1,6,7 43,8 4,7 34,8 33,2 31, 28, 4-2/11A 4-2/D218 1 x 11 63,6 7,8 6,2,2 47,8 44, 38,2 36, 34,8 31,1 4-2/11 4-2/D233 1 x 11 71,7 66, 64,3 63,4,7 2,3 4,8 44, 42,1 38,3 4-2/1 4-2/D21 1 x 1 8, 78,6 76,9 76, 68,4 6, 8,6 6,8, 1,1 42,6 Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-sp-shf4-2p-en_a_th OHn = risk class value referred to the required rated capacity (Tab.6 para EN1284) Inlet pressure drops must be deducted. Make sure that these drops, added to the difference in level (max. 3.2m), are less than 4.m The values shown identify performance levels according to the reference standard EN1284. HYDRAULIC PERFORMANCE TABLE AT HZ (SUCTION LIFT) TABELLA DI PRESTAZIONI IDRAULICHE NETTE GRUPPI EN1284 SERIE SHF4 2 poli Hz 1 POMPA DI SERVIZIO, ASP ESCLUSA, INST SOTT GEN..D/SHF 4 BOOSTER SETS SERIES RISK CLASS GEN..D/SHF TYPE RATED SHF.. POWER OH1n Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 4-12/ /D112 1 x 1,1 13,9 11,3 1, 9,3 3,4,7 4-12/1 4-12/D126 1 x 1, 18, 1,3 14, 13,3 7,4 4,7 4-12/ /D143 1 x 2,2 2,3 21,8 2, 19,8 14, 11,4 6,4, 3,6,6 4-16/3 4-16/D19 1 x 3 31,6 28,1 26,8 26, 19, 16, 1,8 9,2 7,6 4-16/4 4-16/D171 1 x 4 38,3 3,1 33,7 32,9 26, 23,6 18,1 16, 1, 11,7 4-2/ 4-2/D19 1 x, 46,4 42,7 41,2 4,4 33,1 29,7 23,3 21, 19,6 4-2/7 4-2/D29 1 x 7, 7, 3,1 1,6,7 43,8 4,7 34,8 33,2 31, 28, 4-2/11A 4-2/D218 1 x 11 63,6 7,8 6,2,2 47,8 44, 38,2 36, 34,8 31,1 4-2/11 4-2/D233 1 x 11 71,7 66, 64,3 63,4,7 2,3 4,8 44, 42,1 38,3 4-2/1 4-2/D21 1 x 1 8, 78,6 76,9 76, 68,4 6, 8,6 6,8, 1,1 42,6 Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-st-shf4-2p-en_a_th OHn = risk class value referred to the required rated capacity (Tab.6 para EN1284) Inlet pressure drops must be deducted. Make sure these drops are less than 4.m The values shown identify performance levels according to the reference standard EN
99 NPSH REQUIRED FOR PUMP SERIES SHF 4 TABELLA DI PRESTAZIONI IDRAULICHE GRUPPI EN1284 SERIE SHF4 2 poli Hz 1 POMPA DI SERVIZIO RISK CLASS TYPE RATED GEN..D/SHF OH1n OH1m SHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m 3 /h PUMP kw NPSHr [METRES COLUMN OF WATER] 4-12/ /D112 1 x 1,1,7 1, 1, 2, 4-12/1 4-12/D126 1 x 1,,7 1, 1, 2, 2,3 2, 4-12/ /D143 1 x 2,2,7 1, 1, 2, 2,3 2, 2,8 3,1 4-16/3 4-16/D19 1 x 3 1,1 1,4 2,1 2,6 2,9 3,2 3, 3,8 4-16/4 4-16/D171 1 x 4 1,1 1,4 2,1 2,6 2,9 3,2 3, 3,8 4,9 4-2/ 4-2/D19 1 x, 1,4 1,8 2,7 3,4 3,7 3,9 4,2 4,,4 4-2/7 4-2/D29 1 x 7, 1,4 1,8 2,7 3,4 3,7 3,9 4,2 4,,4 6,4 4-2/11A 4-2/D218 1 x 11 1,4 1,4 1,7 3, 4,1, 4-2/11 4-2/D233 1 x 11 1,3 1,4 1,6 1,8 1,9 4-2/1 4-2/D21 1 x 1 1,3 1,4 1,6 1,8 1,9 2,1 2,2 2, 3,3 4,3, The declared NPSH values were obtained in the laboratory and refer to a single service pump OHn, OHm = risk class value referred to the required rated and maximum capacity (Tab.6 para EN1284) Check that NPSHd NPSHr+1m is satisfied at the maximum requested capacity 1284_1p-shf4-2p_NPSHr-en_a_th 99
100 HYDRAULIC PERFORMANCE TABLE AT HZ (POSITIVE SUCTION HEAD) TABELLA DI PRESTAZIONI IDRAULICHE NETTE GRUPPI EN1284 SERIE SHF 2 poli Hz 1 POMPA DI SERVIZIO, ASPESCLUSA INST SOPRA GEN..D/SHF BOOSTER SETS SERIES RISK CLASS TYPE RATED OH2n OH3n SHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER -12/22-12/D119 1 x 2,2 17,2 13,2 12, 11,3,9 3,6 1,2-12/3-12/D13 1 x 3 21,7 17,4 16,1 1,3 9,8 7,6,2 2,8-12/4-12/D139 1 x 4 2,6 21,8 2,6 19,8 14,4 12,1 9,8 7,3 6,,3 4,7-16/ -16/D18 1 x, 34, 29,3 27,8 26,9 2,4 17, 14,4 11,1 9,4 8,3 7,6-16/7-16/D174 1 x 7, 4,7 36,1 34,7 33,9 27,6 24,7 21,6 18,1 16,3 1,2 14,4 12, 1,4-2/11A -2/D197 1 x 11 34, 29,3 27,8 26,9 2,4 17, 14,4 11,1 9,4 8,3 7,6-2/11-2/D29 1 x 11 4,7 36,1 34,7 33,9 27,6 24,7 21,6 18,1 16,3 1,2 14,4 12, -2/1-2/D224 1 x 1 7,3 6, 64, 63, 4,6,4 4,4 39,6-2/18-2/D237 1 x 18, 8,1 73,8 72,1 71,1 62,8 8,7 4,1 48,9 46, 44,2-2/22-2/D2 1 x 22 88,9 83,2 81,6 8,6 72,3 68,4 64, 9,1 6,4 4,7 3,6,6 Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-sp-shf-2p-en_a_th OHn = risk class value referred to the required rated capacity (Tab.6 para EN1284) Inlet pressure drops must be deducted. Make sure that these drops, added to the difference in level (max. 3.2m), are less than 4.m The values shown identify performance levels according to the reference standard EN1284. GEN..D/SHF HYDRAULIC PERFORMANCE TABLE AT HZ (SUCTION LIFT) GEN..D/SHF BOOSTER SETS SERIES TABELLA DI PRESTAZIONI IDRAULICHE NETTE GRUPPI EN1284 SERIE SHF 2 poli Hz 1 POMPA DI SERVIZIO, ASPESCLUSA INST SOTTO TYPE RATED SHF.. POWER OH2n l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER -12/22-12/D119 1 x 2,2 17,2 13,2 12, 11,3,9 3,6 1,2-12/3-12/D13 1 x 3 21,7 17,4 16,1 1,3 9,8 7,6,2 2,8-12/4-12/D139 1 x 4 2,6 21,8 2,6 19,8 14,4 12,1 9,8 7,3 6,,3 4,7-16/ -16/D18 1 x, 34, 29,3 27,8 26,9 2,4 17, 14,4 11,1 9,4 8,3 7,6-16/7-16/D174 1 x 7, 4,7 36,1 34,7 33,9 27,6 24,7 21,6 18,1 16,3 1,2 14,4 12, 1,4-2/11A -2/D197 1 x 11 34, 29,3 27,8 26,9 2,4 17, 14,4 11,1 9,4 8,3 7,6-2/11-2/D29 1 x 11 4,7 36,1 34,7 33,9 27,6 24,7 21,6 18,1 16,3 1,2 14,4 12, -2/1-2/D224 1 x 1 7,3 6, 64, 63, 4,6,4 4,4 39,6-2/18-2/D237 1 x 18, 8,1 73,8 72,1 71,1 62,8 8,7 4,1 48,9 46, 44,2-2/22-2/D2 1 x 22 88,9 83,2 81,6 8,6 72,3 68,4 64, 9,1 6,4 4,7 3,6,6 Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-st-shf-2p-en_a_th OHn = risk class value referred to the required rated capacity (Tab.6 para EN1284) Inlet pressure drops must be deducted. Make sure these drops are less than 4.m The values shown identify performance levels according to the reference standard EN1284. OH3n RISK CLASS Q = DELIVERY 1
101 NPSH REQUIRED FOR PUMP SERIES SHF TABELLA DI PRESTAZIONI IDRAULICHE NPSHr GRUPPI EN1284 SERIE SHF 2 poli Hz 1 POMPA DI SERVIZIO RISK CLASS TYPE RATED OH2n OH2m GEN..D/SHF OH3n OH3m SHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m 3 /h PUMP kw NPSHr [METRES COLUMN OF WATER] -12/22-12/D119 1 x 2,2 1,6 1,8 1,9 2,8 3,4 4,3-12/3-12/D13 1 x 3 1,6 1,8 1,9 2,7 3,1 3,7 4,6-12/4-12/D139 1 x 4 1,6 1,8 1,9 2,7 3,1 3,7 4,6,2,7 6, -16/ -16/D18 1 x, 2, 2,1 2,1 2,8 3,2 3,7 4,7,4,9 6,3-16/7-16/D174 1 x 7, 1,9 2,1 2,2 2,8 3,1 3,6 4,3 4,9,3,6 6, 7,6-2/11A -2/D197 1 x 11 2, 2,1 2,1 2,8 3,2 4,,2 6,1 6,7 7,2-2/11-2/D29 1 x 11 1,9 2,1 2,2 2,8 3,2 3,7 4,7,4,9 6,3 7, -2/1-2/D224 1 x 1 1,6 1,7 1,8 2,3 2,7 3,3 4,8-2/18-2/D237 1 x 18, 1, 1,7 1,8 2,4 2,7 3,1 3,7 4,1 4,4-2/22-2/D2 1 x 22 1, 1,7 1,8 2,4 2,7 3,1 3,7 4,1 4,4 4,7,4 The declared NPSH values were obtained in the laboratory and refer to a single service pump OHn, OHm = risk class value referred to the required rated and maximum capacity (Tab.6 para EN1284) Check that NPSHd NPSHr+1m is satisfied at the maximum requested capacity 1284_1p-shf-2p_NPSHr-en_a_th 11
102 HYDRAULIC PERFORMANCE TABLE AT HZ (POSITIVE SUCTION HEAD) TABELLA DI PRESTAZIONI IDRAULICHE NETTE GRUPPI EN1284 SERIE SHF6 2 poli Hz 1 POMPA DI SERVIZIO, ASP ESCLUSA INST SOPRA GEN..D/SHF 6 BOOSTER SETS SERIES RISK CLASS TYPE RATED OH3n OH4n SHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 6-16/4 6-16/D119 1 x 4 19,6 1,9 14,9 13,8 12,6 9,4 7,3 2,9 6-16/ 6-16/D129 1 x, 24,2 2, 19, 18,4 17,2 13,9 11,7 7,,4 6-16/7 6-16/D137 1 x 7, 28,2 2,1 24,2 23,1 22, 18,8 16,7 12, 1,4 8,7 6-16/11A 6-16/D168 1 x 11 38,2 34,3 33, 31, 29,8 2,2 22, 1,2 12,9 6-16/ /D177 1 x 11 42,9 39,7 38,4 36,9 3,3 3,6 27,4 2, 18,1 1,6 6-2/1 6-2/D192 1 x 1 3, 47, 4,9 44,1 38,9 3,3 27,1 24,1 6-2/18 6-2/D23 1 x 18, 6,2,2 3,6 1,9 46,9 43,4 3, 32,6 29, 6-2/22 6-2/D21 1 x 22 68, 63, 61,6 6,,2 1,9 44,3 41, 38, 37, 3, 6-2/3 6-2/D24 1 x 3 83,7 8,2 78,9 74,9 71,9 64,4 61,4 8,3 6,6 4,9 6-2/37 6-2/D2 1 x 37 96,7 93,6 92,2 88, 84,9 77,4 74,6 71,7 7,1 68, 6,2 Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-sp-shf6-2p-en_a_th OHn = risk class value referred to the required rated capacity (Tab.6 para EN1284) Inlet pressure drops must be deducted. Make sure that these drops, added to the difference in level (max. 3.2m), are less than 4.m The values shown identify performance levels according to the reference standard EN1284. GEN..D/SHF HYDRAULIC PERFORMANCE TABLE AT HZ (SUCTION LIFT) TABELLA DI PRESTAZIONI IDRAULICHE NETTE GRUPPI EN1284 SERIE SHF6 2 poli Hz 1 POMPA DI SERVIZIO, ASP ESCLUSA INST SOTTO GEN..D/SHF 6 BOOSTER SETS SERIES TYPE RATED SHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 6-16/4 6-16/D119 1 x 4 19,6 1,9 14,9 13,8 12,6 9,4 7,3 2,9 6-16/ 6-16/D129 1 x, 24,2 2, 19, 18,4 17,2 13,9 11,7 7,,4 6-16/7 6-16/D137 1 x 7, 28,2 2,1 24,2 23,1 22, 18,8 16,7 12, 1,4 8,7 6-16/11A 6-16/D168 1 x 11 38,2 34,3 33, 31, 29,8 2,2 22, 1,2 12,9 6-16/ /D177 1 x 11 42,9 39,7 38,4 36,9 3,3 3,6 27,4 2, 18,1 1,6 6-2/1 6-2/D192 1 x 1 3, 47, 4,9 44,1 38,9 3,3 27,1 24,1 6-2/18 6-2/D23 1 x 18, 6,2,2 3,6 1,9 46,9 43,4 3, 32,6 29, 6-2/22 6-2/D21 1 x 22 68, 63, 61,6 6,,2 1,9 44,3 41, 38, 37, 3, 6-2/3 6-2/D24 1 x 3 83,7 8,2 78,9 74,9 71,9 64,4 61,4 8,3 6,6 4,9 6-2/37 6-2/D2 1 x 37 96,7 93,6 92,2 88, 84,9 77,4 74,6 71,7 7,1 68, 6,2 Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-st-shf6-2p-en_a_th OHn = risk class value referred to the required rated capacity (Tab.6 para EN1284) Inlet pressure drops must be deducted. Make sure these drops are less than 4.m The values shown identify performance levels according to the reference standard EN1284. OH3n RISK CLASS OH4n 12
103 NPSH REQUIRED FOR PUMP SERIES SHF 6 TABELLA DI PRESTAZIONI IDRAULICHE NPSHr GRUPPI EN1284 SERIE SHF6 2 poli Hz 1 POMPA DI SERVIZIO RISK CLASS TYPE RATED GEN..D/SHF OH3n OH3m OH4n OH4m SHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m 3 /h PUMP kw NPSHr [METRES COLUMN OF WATER] 6-16/4 6-16/D119 1 x 4 1,9 1,8 1,9 1,9 2, 2,7 3,3 7,4 6-16/ 6-16/D129 1 x, 1,9 1,9 1,9 1,9 2,4 2,6 3,1,4 6,6 6-16/7 6-16/D137 1 x 7, 1,9 1,9 1,9 1,9 2,4 2,6 3,1,4 6,6 8, 6-16/11A 6-16/D168 1 x 11 1,3 1,4 1,6 1,7 2,1 2,1 2,4 3, 4,2 6-16/ /D177 1 x 11 1,3 1,4 1,6 1,7 2,1 2,1 2,4 3, 4,2,2 6-2/1 6-2/D192 1 x 1 1,7 1,7 1,6 1,7 1,7 1,9 4,1 6,4 6-2/18 6-2/D23 1 x 18, 1,7 1,7 1,6 1,7 1,7 1,9 3, 3,9,3 6-2/22 6-2/D21 1 x 22 1,7 1,7 1,6 1,7 1,7 1,9 3, 3,9,3 7, 6-2/3 6-2/D24 1 x 3 1,3 1,3 1,4 1, 1,7 3,2 4,1,4 7, 6-2/37 6-2/D2 1 x 37 1,3 1,3 1,3 1,4 1,6 2,9 3,7 4,8 6,2 8,1 The declared NPSH values were obtained in the laboratory and refer to a single service pump OHn, OHm = risk class value referred to the required rated and maximum capacity (Tab.6 para EN1284) Check that NPSHd NPSHr+1m is satisfied at the maximum requested capacity 1284_1p-shf6-2p_NPSHr-en_a_th 13
104 HYDRAULIC PERFORMANCE TABLE AT HZ (POSITIVE SUCTION HEAD) TABELLA DI PRESTAZIONI IDRAULICHE NETTE GRUPPI EN1284 SERIE SHF8 2 poli Hz 1 POMPA DI SERVIZIO, ASP ESCLUSA INST SOPRA GEN..D/SHF 8 BOOSTER SETS SERIES RISK CLASS TYPE RATED OH4n HH1n SHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 8-16/ /D169 1 x 11 33, 3,9 28,6 2,7 22,2 19,7 6,2 4,8 8-16/1 8-16/D177 1 x 1 39, 37,8 3,6 32,7 29,4 26,9 13,2 11,8 8,4 8-16/ /D186 1 x 18, 46,4 44,7 42,6 39,8 36,6 34,2 2,7 19,3 1,9 14,1 12,4 8-2/22 8-2/D198 1 x 22 1,9 48, 4,8 42, 4,1 26,7 2,3 21,9 2,2 8-2/3 8-2/D21 1 x 3 62,2 9,7 7,1 3,9 1, 37,8 36,4 32,9 31,1 29,3 27,4 8-2/37 8-2/D226 1 x 37 69,8 69,9 68,1 6,7 62,8 6, 47,2 4,7 42,2 4,4 38, 36,6 32,7 8-2/4 8-2/D237 1 x 4 82,2 79,1 76,2 72,6 69,8 3,3 1, 47, 44,6 8-2/ 8-2/D22 1 x 93,9 91,9 89,2 8,9 83,2 67,7 66, 61,8 9,6 7,3 8-2/7 8-2/D27 1 x 7 19,7 18,6 16, 12,7 1,2 8, 83,3 79,2 77, 74,8 72, Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-sp-shf8-2p-en_a_th OHn = risk class value referred to the required rated capacity (Tab.6 para EN1284) Inlet pressure drops must be deducted. Make sure that these drops, added to the difference in level (max. 3.2m), are less than 4.m The values shown identify performance levels according to the reference standard EN1284. GEN..D/SHF HYDRAULIC PERFORMANCE TABLE AT HZ (SUCTION LIFT) TABELLA DI PRESTAZIONI IDRAULICHE NETTE GRUPPI EN1284 SERIE SHF8 2 poli Hz 1 POMPA DI SERVIZIO, ASP ESCLUSA INST SOTTO GEN..D/SHF 8 BOOSTER SETS SERIES TYPE RATED SHF.. POWER OH4n l/min ELECTRIC PUMP m3/h PUMP kw H = TOTAL HEAD METRES COLUMN OF WATER 8-16/ /D169 1 x 11 33, 3,9 28,6 2,7 22,2 19,7 6,2 4,8 8-16/1 8-16/D177 1 x 1 39, 37,8 3,6 32,7 29,4 26,9 13,2 11,8 8,4 8-16/ /D186 1 x 18, 46,4 44,7 42,6 39,8 36,6 34,2 2,7 19,3 1,9 14,1 12,4 8-2/22 8-2/D198 1 x 22 1,9 48, 4,8 42, 4,1 26,7 2,3 21,9 2,2 8-2/3 8-2/D21 1 x 3 62,2 9,7 7,1 3,9 1, 37,8 36,4 32,9 31,1 29,3 27,4 8-2/37 8-2/D226 1 x 37 69,8 69,9 68,1 6,7 62,8 6, 47,2 4,7 42,2 4,4 38, 36,6 32,7 8-2/4 8-2/D237 1 x 4 82,2 79,1 76,2 72,6 69,8 3,3 1, 47, 44,6 8-2/ 8-2/D22 1 x 93,9 91,9 89,2 8,9 83,2 67,7 66, 61,8 9,6 7,3 8-2/7 8-2/D27 1 x 7 19,7 18,6 16, 12,7 1,2 8, 83,3 79,2 77, 74,8 72, Performance levels relative to set with 1 service pump running and compliant with ISO Annex A. 1284_1pg-st-shf8-2p-en_a_th OHn = risk class value referred to the required rated capacity (Tab.6 para EN1284) Inlet pressure drops must be deducted. Make sure these drops are less than 4.m The values shown identify performance levels according to the reference standard EN1284. HH1n RISK CLASS Q = DELIVERY 14
105 NPSH REQUIRED FOR PUMP SERIES SHF 8 TABELLA DI PRESTAZIONI IDRAULICHE GRUPPI EN1284 SERIE SHF8 2 poli Hz 1 POMPA DI SERVIZIO RISK CLASS TYPE RATED OH4n GEN..D/SHF OH4m HH1n HH1m SHF.. POWER Q = DELIVERY l/min ELECTRIC PUMP m 3 /h PUMP kw NPSHr [METRES COLUMN OF WATER] 8-16/ /D169 1 x 11 2,3 2, 2,7 3, 3,2,9 6, 8-16/1 8-16/D177 1 x 1 2,3 2, 2,7 2,9 3, 4,3 4,6, 8-16/ /D186 1 x 18, 2,3 2, 2,7 2,9 3, 4,3 4,6, 6,1 6,8 8-2/22 8-2/D198 1 x 22 2,2 2,4 2,7 2,8 3,9 4,1 4,6 4,9 8-2/3 8-2/D21 1 x 3 2,2 2,4 2,6 2,8 3,7 3,8 4,2 4,4 4,7, 8-2/37 8-2/D226 1 x 37 2, 2,2 2,4 2,6 2,8 3,7 3,8 4,2 4,4 4,7, 6, 8-2/4 8-2/D237 1 x 4 1,9 2,2 2,4 2,6 3,6 3,7 4,2 4,6 8-2/ 8-2/D22 1 x 1,9 2,2 2,4 2,6 3,6 3,7 4,2 4,6,1 8-2/7 8-2/D27 1 x 7 1,9 2,2 2,4 2,6 3,6 3,7 4,2 4,6,1 6, The declared NPSH values were obtained in the laboratory and refer to a single service pump 1284_1p-shf8-2p_NPSHr-en_a_th OHn, OHm, HHn, HHm = risk class value referred to the required rated and maximum capacity (Tab.6 para 7.3.1, Tab.7 para EN1284) Check that NPSHd NPSHr+1m is satisfied at the maximum requested capacity 1
106 GEN..D/SHF GEN..D/SHF 32-8 BOOSTER SETS TABELLA DATI ELETTRICI GRUPPI GEN..D/SHF 2 poli Hz ELECTRICAL DATA A TABLE AT Hz SERVICE ELECTRIC JOCKEY CURRENT (*) PUMP PUMP ABSORBED SET 3 X 4 V 1 x 23V 3x4 TYPE NOMINAL 1x23V 3x4V SHF.. POWER ELECTRIC Pn In TYPE Pn In In GEN..D GEN..1D GEN..1D GEN..11D PUMP PUMP kw A kw A A A A A A 32-12/ /D121,7 1,76 1SV 7,37 2,82 1,3 3,82 4,76 6, / /D136 1,1 2,36 1SV 8, 3,88 1,48 3 6,88,36 6, / /D1 1, 3,2 1SV 8, 3,88 1,48 3 6,88 6,2 7, 32-16/ /D168 2,2 4,64 1SV 9, 3,88 1,48 3 6,88 7,64 9,1 32-2/3 32-2/D188 3,91 1SV 11, 3,88 1,48 3 6,88 8,91 1,4 32-2/4 32-2/D24 4 7, 1SV 12,7 4,88 1,76 3 7,88 1, 12,3 32-2/ 32-2/D222, 11 1SV 12,7 4,88 1,76 3 7, ,8 32-2/7 32-2/D242 7, 14,3 1SV 1,7 4,88 1,76 3 7,88 17,3 19,1 32-2/ /D ,8 1SV 17 1,1 6,77 2,36 3 9,77 22,8 2,2 4-12/ /D112 1,1 2,36 1SV 7,37 2,82 1,3 3,82,36 6, /1 4-12/D126 1, 3,2 1SV 7,37 2,82 1,3 3,82 6,2 7, / /D143 2,2 4,64 1SV 8, 3,88 1,48 3 6,88 7,64 9,1 4-16/3 4-16/D19 3,91 1SV 9, 3,88 1,48 3 6,88 8,91 1,4 4-16/4 4-16/D , 1SV 1, 3,88 1,48 3 6,88 1, 12, 4-2/ 4-2/D19, 11 1SV 11, 3,88 1,48 3 6, , 4-2/7 4-2/D29 7, 14,3 1SV 12,7 4,88 1,76 3 7,88 17,3 19,1 4-2/11A 4-2/D ,8 1SV 13,7 4,88 1,76 3 7,88 22,8 24,6 4-2/11 4-2/D ,8 1SV 1,7 4,88 1,76 3 7,88 22,8 24,6 4-2/1 4-2/D ,2 1SV 17 1,1 6,77 2,36 3 9,77 29,2 31,6-12/22-12/D119 2,2 4,64 1SV 7,37 2,82 1,3 3,82 7,64 9, -12/3-12/D13 3,91 1SV 8, 3,88 1,48 3 6,88 8,91 1,4-12/4-12/D , 1SV 8, 3,88 1,48 3 6,88 1, 12, -16/ -16/D18, 11 1SV 9, 3,88 1,48 3 6, , -16/7-16/D174 7, 14,3 1SV 1, 3,88 1,48 3 6,88 17,3 18,8-2/11A -2/D ,8 1SV 12,7 4,88 1,76 3 7,88 22,8 24,6-2/11-2/D ,8 1SV 12,7 4,88 1,76 3 7,88 22,8 24,6-2/1-2/D ,2 1SV 1,7 4,88 1,76 3 7,88 29,2 31, -2/18-2/D237 18, 32,9 1SV 1,7 4,88 1,76 3 7,88 3,9 37,7-2/22-2/D ,1 1SV 17 1,1 6,77 2,36 3 9,77 42,1 44, 6-16/4 6-16/D , 1SV 8, 3,88 1,48 3 6,88 1, 12, 6-16/ 6-16/D129, 11 1SV 8, 3,88 1,48 3 6, , 6-16/7 6-16/D137 7, 14,3 1SV 8, 3,88 1,48 3 6,88 17,3 18,8 6-16/11A 6-16/D ,8 1SV 1, 3,88 1,48 3 6,88 22,8 24,3 6-16/ /D ,8 1SV 1, 3,88 1,48 3 6,88 22,8 24,3 6-2/1 6-2/D ,2 1SV 12,7 4,88 1,76 3 7,88 29,2 31, 6-2/18 6-2/D23 18, 32,9 1SV 12,7 4,88 1,76 3 7,88 3,9 37,7 6-2/22 6-2/D ,1 1SV 1,7 4,88 1,76 3 7,88 42,1 43,9 6-2/3 6-2/D24 3 3,6 1SV 17 1,1 6,77 2,36 3 9,77 6,6 9, 6-2/37 6-2/D2 37 6,8 1SV 17 1,1 6,77 2,36 3 9,77 68,8 71,2 8-16/ /D ,8 1SV 9, 3,88 1,48 3 6,88 22,8 24,3 8-16/1 8-16/D ,7 1SV 1, 3,88 1,48 3 6,88 29,7 31,2 8-16/ /D186 18, 32,9 1SV 11, 3,88 1,48 3 6,88 3,9 37,4 8-2/22 8-2/D ,1 1SV 12,7 4,88 1,76 3 7,88 42,1 43,9 8-2/3 8-2/D21 3 3,6 1SV 13,7 4,88 1,76 3 7,88 6,6 8,4 8-2/37 8-2/D ,8 1SV 1,7 4,88 1,76 3 7,88 68,8 7,6 8-2/4 8-2/D SV 1,7 4,88 1,76 3 7, ,8 8-2/ 8-2/D22 9 1SV 17 1,1 6,77 2,36 3 9, ,4 8-2/7 8-2/D SV 19 1,1 6,77 2,36 3 9, ,4 ENMTP-SHF_2p-en_d_te (*) The current indicated is the maximum current absorbed. At the set 3x4V three-phase power supply GEN..1D and GEN..11D to add the control panel current of the engine pump (GEN..D) 1x23V The sets GEN..1D have the electric jockey pump 1x23V single-phase power supply. 16
107 Fire-fighting booster sets EN 1284 MARKET SECTORS CIVIL, INDUSTRIAL APPLICATIONS Fixed fire-fighting systems. Automatic Sprinkler systems. DSHF Series SPECIFICATIONS Flow up to 22 m 3 /h. Diesel engine with battery start. GEN..D/SHF Head up to 1 m. Panel supply power voltage: 1 x 23V ± 1%. Frequency: Hz. Voltage for controls outside panel: Vac. Protection grade: - electric panel: IP4. Electric pumps maximum power 7 kw. Diesel engine service pump in horizontal design: - SHF series. Maximum running pressure: 12 bar. 17
108 DSHF 32-8 DIESEL ENGINE PUMP SERIES FIRE-FIGHTING EN 1284 For the overall dimensions of the fuel tank and the starting batteries, see tables on pages 2-2. GEN..D/SHF 18
109 DSHF 32-8 DIESEL ENGINE PUMP SERIES FIRE-FIGHTING EN 1284 D.. DNA DNM A B C E F H H1 H2 SHFE32-12/D121 R 2" SHFE32-12/D136 R 2" SHFE32-16/D1 R 2" SHFE32-16/D168 R 2" SHFE32-2/D188 R 2" SHFE32-2/D24 R 2" SHFE32-2/D222 R 2" SHFE32-2/D242 R 2" SHFE32-2/D26 R 2" SHFE4-12/D SHFE4-12/D SHFE4-12/D SHFE4-16/D SHFE4-16/D SHFE4-2/D SHFE4-2/D SHFE4-2/D SHFE4-2/D SHFE4-2/D SHFE-12/D SHFE-12/D SHFE-12/D SHFE-16/D SHFE-16/D SHFE-2/D SHFE-2/D SHFE-2/D SHFE-2/D SHFE-2/D SHFE6-16/D SHFE6-16/D SHFE6-16/D SHFE6-16/D SHFE6-16/D SHFE6-2/D SHFE6-2/D SHFE6-2/D SHFE6-2/D SHFE6-2/D SHFE8-16/D SHFE8-16/D SHFE8-16/D SHFE8-2/D SHFE8-2/D SHFE8-2/D SHFE8-2/D SHFE8-2/D SHFE8-2/D Dimensions in mm. Tolerance ± 1 mm. d_shfe-en_f_td GEN..D/SHF 19
110 GEN..D/SHF 11
111 Fire-fighting booster sets EN 1284 MARKET SECTORS CIVIL, INDUSTRIAL APPLICATIONS Fixed fire-fighting systems. Automatic Sprinkler systems. GEN..D/SHF Series SPECIFICATIONS Flow up to 22 m 3 /h. Diesel engine with battery start. GEN..D/SHF Head up to 1 m. Panel supply power voltage: 1 x 23V ± 1%. Frequency: Hz. Voltage for controls outside panel: Vac. Protection grade: - electric panel: IP4. Electric pumps maximum power 7 kw. Diesel engine service pump in horizontal design: - SHF series. Maximum running pressure: 12 bar. 111
112 GEN..D/SHF 32-8 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..D/SHF For the overall dimensions of the fuel tank and the starting batteries, see tables on pages
113 GEN..D/SHF 32-8 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..D DRW N DNA DNM A B D E G N P Q SHF32-12/D121 1 R 2" R 1"1/ SHF32-12/D136 1 R 2" R 1"1/ SHF32-16/D1 1 R 2" R 1"1/ SHF32-16/D168 1 R 2" R 1"1/ SHF32-2/D188 1 R 2" R 1"1/ SHF32-2/D24 1 R 2" R 1"1/ SHF32-2/D222 1 R 2" R 1"1/ SHF32-2/D242 1 R 2" R 1"1/ SHF32-2/D26 1 R 2" R 1"1/ SHF4-12/D SHF4-12/D SHF4-12/D SHF4-16/D SHF4-16/D SHF4-2/D SHF4-2/D SHF4-2/D SHF4-2/D SHF4-2/D SHF-12/D SHF-12/D SHF-12/D SHF-16/D SHF-16/D SHF-2/D SHF-2/D SHF-2/D SHF-2/D SHF-2/D SHF6-16/D SHF6-16/D SHF6-16/D SHF6-16/D SHF6-16/D SHF6-2/D SHF6-2/D SHF6-2/D SHF6-2/D SHF6-2/D SHF8-16/D SHF8-16/D SHF8-16/D SHF8-2/D SHF8-2/D SHF8-2/D SHF8-2/D SHF8-2/D SHF8-2/D Dimensions in mm. Tolerance ± 1 mm. gend_shf-en_h_td GEN..D/SHF 113
114 GEN..D/SHF 114
115 Fire-fighting booster sets EN 1284 MARKET SECTORS CIVIL, INDUSTRIAL APPLICATIONS Fixed fire-fighting systems. Automatic Sprinkler systems. GEN..1D/SHF Series SPECIFICATIONS GEN..D/SHF Flow up to 22 m 3 /h. Head up to 1 m. Panel supply power voltage: - Electric pump: 1 x 23V ± 1%. - Diesel engine pump: 1 x 23V ± 1%. Frequency: Hz. Voltage for controls outside panel: Vac. Protection grade: - electric panel: IP4. Electric pumps maximum power 7 kw. Electric motor start : - Direct start for powers up to 22 kw included for electric pump. Diesel engine with battery start. Service pump in horizontal design: - SHF series. Electric jockey pump with vertical axis: - SV Series (motor protection grade IP). Maximum running pressure: 12 bar. 11
116 GEN..1D/SHF 32-8 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..D/SHF For the overall dimensions of the fuel tank and the starting batteries, see tables on pages
117 GEN..1D/SHF 32-8 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..1D DRW N DNA DNP DNM A A1 B C D F G H I L N P Q SHF32-12/D121 1 R 2" Rp 1" R 1"1/ SHF32-12/D136 1 R 2" Rp 1" R 1"1/ SHF32-16/D1 1 R 2" Rp 1" R 1"1/ SHF32-16/D168 1 R 2" Rp 1" R 1"1/ SHF32-2/D188 1 R 2" Rp 1" R 1"1/ SHF32-2/D24 1 R 2" Rp 1" R 1"1/ SHF32-2/D222 1 R 2" Rp 1" R 1"1/ SHF32-2/D242 1 R 2" Rp 1" R 1"1/ SHF32-2/D26 1 R 2" Rp 1" R 1"1/ SHF4-12/D Rp 1" SHF4-12/D Rp 1" SHF4-12/D Rp 1" SHF4-16/D Rp 1" SHF4-16/D Rp 1" SHF4-2/D Rp 1" SHF4-2/D Rp 1" SHF4-2/D Rp 1" SHF4-2/D Rp 1" SHF4-2/D Rp 1" SHF-12/D Rp 1" SHF-12/D Rp 1" SHF-12/D Rp 1" SHF-16/D Rp 1" SHF-16/D Rp 1" SHF-2/D Rp 1" SHF-2/D Rp 1" SHF-2/D Rp 1" SHF-2/D Rp 1" SHF-2/D2 2 6 Rp 1" SHF6-16/D Rp 1" SHF6-16/D Rp 1" SHF6-16/D Rp 1" SHF6-16/D Rp 1" SHF6-16/D Rp 1" SHF6-2/D Rp 1" SHF6-2/D Rp 1" SHF6-2/D Rp 1" SHF6-2/D Rp 1" SHF6-2/D2 2 8 Rp 1" SHF8-16/D Rp 1" SHF8-16/D Rp 1" SHF8-16/D Rp 1" SHF8-2/D Rp 1" SHF8-2/D Rp 1" SHF8-2/D Rp 1" SHF8-2/D Rp 1" SHF8-2/D Rp 1" SHF8-2/D Rp 1" * * Wall mounted control panel. gen1d_shf-en_g_td Dimensions in mm. Tolerance ± 1 mm. GEN..D/SHF 117
118 GEN..D/SHF 118
119 Fire-fighting booster sets EN 1284 MARKET SECTORS CIVIL, INDUSTRIAL APPLICATIONS Fixed fire-fighting systems. Automatic Sprinkler systems. Serie GEN..1D/SHF SPECIFICATIONS GEN..D/SHF Flow up to 44 m 3 /h. Head up to1 m. Panel supply power voltage: - Electric pump: 3 x 4V ± 1%. - Diesel engine pump: 1 x 23V ± 1%. Frequency: Hz. Voltage for controls outside panel: Vac. Protection grade: - electric panel: IP4. Electric motor start : - Direct start for powers up to 22 kw included for pump (GEND...). - Star/delta start for higher powers (GENY... set). Diesel engine with battery start. Service pump in horizontal design: - SHF series (IP electric motor protection). Maximum running pressure: 12 bar. Electric pumps maximum power 7 kw. 119
120 GEN..1D/SHF 32-8 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..D/SHF For the overall dimensions of the fuel tank and the starting batteries, see tables on pages
121 GEN..1D/SHF 32-8 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..1D DRW N DNA DNM A A1 B C D G H I L N P Q SHF32-12/7/D121 1 R 2" R 2" SHF32-12/11/D136 1 R 2" R 2" SHF32-16/1/D1 1 R 2" R 2" SHF32-16/22/D168 1 R 2" R 2" SHF32-2/3/D188 1 R 2" R 2" SHF32-2/4/D24 1 R 2" R 2" SHF32-2//D222 1 R 2" R 2" SHF32-2/7/D242 1 R 2" R 2" SHF32-2/11/D26 1 R 2" R 2" SHF4-12/11/D SHF4-12/1/D SHF4-12/22/D SHF4-16/3/D SHF4-16/4/D SHF4-2//D SHF4-2/7/D SHF4-2/11A/D SHF4-2/11/D SHF4-2/1/D SHF-12/22/D SHF-12/3/D SHF-12/4/D SHF-16//D SHF-16/7/D SHF-2/11A/D SHF-2/11/D SHF-2/1/D SHF-2/18/D SHF-2/22/D SHF6-16/4/D SHF6-16//D SHF6-16/7/D SHF6-16/11A/D SHF6-16/11/D SHF6-2/1/D SHF6-2/18/D SHF6-2/22/D SHF6-2/3/D SHF6-2/37/D SHF8-16/11/D SHF8-16/1/D SHF8-16/18/D SHF8-2/22/D SHF8-2/3/D SHF8-2/37/D SHF8-2/4/D SHF8-2//D SHF8-2/7/D * * Wall mounted control panel. gen1d_shf-en_f_td Dimensions in mm. Tolerance ± 1 mm. GEN..D/SHF 121
122 GEN..D/SHF 122
123 Fire-fighting booster sets EN 1284 MARKET SECTORS CIVIL, INDUSTRIAL APPLICATIONS Fixed fire-fighting systems. Automatic Sprinkler systems. GEN..11D/SHF Series SPECIFICATIONS GEN..D/SHF Flow up to 44 m 3 /h. Head up to 1 m. Panel supply power voltage: - Electric pump: 3 x 4V ± 1%. - Diesel engine pump: 1 x 23V ± 1%. Frequency: Hz. Voltage for controls outside panel: Vac. Protection grade: - electric panel: IP4. Electric pumps maximum power 7 kw. Electric motor start : - Direct start for powers up to 22 kw included for pump (GEND...). - Star/delta start for higher powers (GENY... set). Diesel engine with battery start. Service pump in horizontal design: - SHF series (IP electric motor protection). Electric jockey pump with vertical axis: - SV Series (motor protection grade IP). Maximum running pressure: 12 bar. 123
124 GEN..11D/SHF 32-8 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..D/SHF For the overall dimensions of the fuel tank and the starting batteries, see tables on pages
125 GEN..11D/SHF 32-8 SERIES FIRE-FIGHTING BOOSTER SETS EN 1284 GEN..11D DRW DNA DNP DNM A A1 B C D F G H I I1 L N P Q N SHF32-12/7/D121 1 R 2" Rp 1" R 2" SHF32-12/11/D136 1 R 2" Rp 1" R 2" SHF32-16/1/D1 1 R 2" Rp 1" R 2" SHF32-16/22/D168 1 R 2" Rp 1" R 2" SHF32-2/3/D188 1 R 2" Rp 1" R 2" SHF32-2/4/D24 1 R 2" Rp 1" R 2" SHF32-2//D222 1 R 2" Rp 1" R 2" SHF32-2/7/D242 1 R 2" Rp 1" R 2" SHF32-2/11/D26 1 R 2" Rp 1" R 2" SHF4-12/11/D Rp 1" SHF4-12/1/D Rp 1" SHF4-12/22/D Rp 1" SHF4-16/3/D Rp 1" SHF4-16/4/D Rp 1" SHF4-2//D Rp 1" SHF4-2/7/D Rp 1" SHF4-2/11A/D Rp 1" SHF4-2/11/D Rp 1" SHF4-2/1/D Rp 1" SHF-12/22/D Rp 1" SHF-12/3/D Rp 1" SHF-12/4/D Rp 1" SHF-16//D Rp 1" SHF-16/7/D Rp 1" SHF-2/11A/D Rp 1" SHF-2/11/D Rp 1" SHF-2/1/D Rp 1" SHF-2/18/D Rp 1" SHF-2/22/D2 2 6 Rp 1" SHF6-16/4/D Rp 1" SHF6-16//D Rp 1" SHF6-16/7/D Rp 1" SHF6-16/11A/D Rp 1" SHF6-16/11/D Rp 1" SHF6-2/1/D Rp 1" SHF6-2/18/D Rp 1" SHF6-2/22/D Rp 1" SHF6-2/3/D Rp 1" SHF6-2/37/D2 2 8 Rp 1" SHF8-16/11/D Rp 1" SHF8-16/1/D Rp 1" SHF8-16/18/D Rp 1" SHF8-2/22/D Rp 1" SHF8-2/3/D Rp 1" SHF8-2/37/D Rp 1" SHF8-2/4/D Rp 1" SHF8-2//D Rp 1" SHF8-2/7/D Rp 1" * * Wall mounted control panel. gen11d_shf-en_h_td Dimensions in mm. Tolerance ± 1 mm. GEN..D/SHF 12
126 GEN..D/SHF 126
127 GEN..D/SHF SERIES OF BOOSTER SETS (POSITIVE SUCTION HEAD) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT SH [rpm] ISO Annex A SH [rpm] ISO Annex A Q [Imp gpm] Q [Imp gpm] Q [US gpm],2,8 Hc [m] H [ft],2, Q [US gpm],2,8 Hc [m] H [ft],2,6,1,1,4,1,1,4,,2,,2, 6,, 8, NPSHr [m] 2 1 NPSHr [ft] NPSHr [m] /1 φ / /1 Ø φ NPSHr [ft] Q [m 3 /h] Q [l/min] 7617_A_CH Q [m 3 3 /h] Q [l/min] 7618_A_CH SH [rpm] ISO Annex A Q [Imp gpm] Q [US gpm],2,8 Hc [m] H [ft],2,6 SH [rpm] ISO Annex A Q [Imp gpm] Q [US gpm],2,8 Hc [m] H [ft],2,6 GEN..D/SHF,1,1,4,1,1,4,,2,,2, 8, 2, 8, / φ NPSHr [m] /3 φ /4 φ /1 Ø NPSHr [ft] NPSHr [m] /11 φ /7 φ /1 Ø NPSHr [ft] Q [m 3 3 /h] Q [l/min] 7619_A_CH Q [m 3 3 /h] Q [l/min] 762_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 127
128 GEN..D/SHF SERIES OF BOOSTER SETS (POSITIVE SUCTION HEAD) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT SH [rpm] ISO Annex A SH [rpm] ISO Annex A 1 1 Q [Imp gpm] 1 1 Q [Imp gpm] Hc [m] 1 1 2,2,2 Q [US gpm],8,6 H [ft] Q [US gpm],2,8 Hc [m] H [ft],2,6,1,1,4,1,1,4,,2,,2, 8, 2, 8, NPSHr [m] NPSHr [ft] NPSHr [m] NPSHr [ft] Q [m 3 /h] Q 8 [l/min] 7621_A_CH Q [m 3 /h] Q 8 [l/min] 7622_A_CH GEN..D/SHF SH [rpm] ISO Annex A 1 1 Q [Imp gpm] Q [US gpm],2,8 Hc [m] H [ft],2,6 SH [rpm] ISO Annex A Q [Imp gpm] Q [US 2gpm],2,8 Hc [m] H [ft],2,6,1,1,4,1,1,4,,2,,2, 8, 2, 8, NPSHr [m] NPSHr [ft] NPSHr [m] 4 4-2/11A φ /1 Ø NPSHr [ft] /1 φ /11 φ Q [m 3 /h] Q 8 [l/min] 7623_A_CH Q [m 3 6 /h] Q [l/min] _A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 128
129 GEN..D/SHF SERIES OF BOOSTER SETS (POSITIVE SUCTION HEAD) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT SH [rpm] ISO Annex A SH [rpm] ISO Annex A Q [Imp gpm] Q [Imp gpm] Q [US gpm],2,8 Hc [m] H [ft],2, Q [US gpm],2,8 Hc [m] H [ft],2,6,1,1,4,1,1,4,,2,,2, 8, 2, 1, NPSHr [m] 4-12/22 φ /4 φ /3 φ /1 Ø NPSHr [ft] NPSHr [m] / φ /1-16/7 Ø 178 φ NPSHr [ft] Q [m1 3 /h] Q 16 [l/min] 762_A_CH Q [m1 3 /h] Q 16 [l/min] 7626_A_CH Hc [m] SH [rpm] ISO Annex A Q [Imp gpm] Q [US gpm],3,2,8,2,6 H [ft] Hc [m] SH [rpm] ISO Annex A Q [Imp gpm] Q [US gpm],3,2,8,2,6 H [ft] GEN..D/SHF,1,1,4,4,1,1,,2,,2, 1,, 1, /11A φ NPSHr [m] 4-2/11 φ /1 Ø NPSHr [ft] NPSHr [m] 4-2/1 φ /1 Ø NPSHr [ft] 1-2/22 φ 2-2/18 φ Q [m1 3 /h] Q 16 [l/min] 7627_A_CH Q [m1 3 /h] Q 16 [l/min] 7628_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 129
130 GEN..D/SHF SERIES OF BOOSTER SETS (POSITIVE SUCTION HEAD) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT SH [rpm] ISO Annex A SH [rpm] ISO Annex A Q [Imp gpm] Q [US 6 gpm], Q [Imp gpm] Q [US 6 gpm],4 Hc [m],2,8 H [ft] Hc [m],3 1,2 1, H [ft],2,6,8,1,4,2,6,1,,2,1,4,2, 1,, 1, /22 φ NPSHr [m] /4 φ /3 φ /1 Ø NPSHr [ft] NPSHr [m] /1 Ø NPSHr [ft] /11 φ /11A φ Q [m14 3 /h] Q 22 [l/min] 7629_A_CH Q [m14 3 /h] Q 22 [l/min] 763_A_CH GEN..D/SHF Hc [m] SH [rpm] ISO Annex A Q [Imp gpm] Q [US 6 gpm],4 1,2,3 1,,8 H [ft] Hc [m] SH [rpm] ISO Annex A Q [Imp gpm] Q [US gpm] 7,6, 1,,4 H [ft],2,6,3 1,,1,4,2,,2,1, 1,, 1, NPSHr [m] /1 φ /1 Ø NPSHr [ft] NPSHr [m] /3 φ /37 φ /1 Ø NPSHr [ft] 6-2/22 φ /18 φ Q [m14 3 /h] Q 22 [l/min] 7631_A_CH Q [m16 3 /h] Q [l/min] 7632_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 13
131 GEN..D/SHF SERIES OF BOOSTER SETS (POSITIVE SUCTION HEAD) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT SH [rpm] ISO Annex A SH [rpm] ISO Annex A Q [Imp gpm] Q [Imp gpm] Q [US gpm], Q [US gpm],4 Hc [m] 1,2 H [ft] Hc [m] H [ft],3 1,,3 1,,8,2,6,2 1,,1,4,1,,2, 1,, 1, /1 φ 169x /22 φ NPSHr [m] /1 Ø NPSHr [ft] NPSHr [m] 4 8-2/37 φ /3 6-16/1 φ 21 Ø NPSHr [ft] 8-16/18 φ /1 φ Q [m2 3 /h] Q 4 [l/min] 7633_A_CH Q [m3 3 /h] Q [l/min] 7634_A_CH Hc [m] SH [rpm] ISO Annex A Q [Imp gpm] Q [US gpm],4 1,2,3 1,,8 H [ft] GEN..D/SHF,2,6,1,4,2, 1, NPSHr [m] /1 Ø NPSHr [ft] Q [m2 3 /h] Q [l/min] 763_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 131
132 GEN..D/SHF SERIES OF BOOSTER SETS (SUCTION LIFT) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT SH [rpm] ISO Annex A SH [rpm] ISO Annex A Q [Imp gpm] Q [US gpm], Q [Imp gpm] Q [US gpm],6 Hc [m] H [ft] Hc [m], H [ft],3 1, 1,,4,2,3 1,,,2,1,,1, 6,, 8, NPSHr [m] 2 1 NPSHr [ft] NPSHr [m] /1 φ / /1 Ø φ NPSHr [ft] Q [m 3 /h] Q [l/min] 76497_A_CH Q [m 3 3 /h] Q [l/min] 76498_A_CH GEN..D/SHF Hc [m] SH [rpm] ISO Annex A Q [Imp gpm] Q [US gpm],6, 1,,4 H [ft] Hc [m] SH [rpm] ISO Annex A Q [Imp gpm] Q [US gpm],6, 1,,4 H [ft],3 1,,3 1,,2,2,,,1,1, 8, 2, 8, / φ NPSHr [m] /3 φ /4 φ /1 Ø NPSHr [ft] NPSHr [m] /11 φ /7 φ /1 Ø NPSHr [ft] Q [m 3 3 /h] Q [l/min] 76499_A_CH Q [m 3 3 /h] Q [l/min] 76_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 132
133 GEN..D/SHF SERIES OF BOOSTER SETS (SUCTION LIFT) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT SH [rpm] ISO Annex A SH [rpm] ISO Annex A 1 1 Q [Imp gpm] 1 1 Q [Imp gpm] 1 1 2,6 Q [US gpm] Q [US gpm],6 Hc [m], H [ft] Hc [m], H [ft] 1, 1,,4,4,3 1,,3 1,,2,2,,,1,1, 8, 2, 8, NPSHr [m] NPSHr [ft] NPSHr [m] NPSHr [ft] Q [m 3 /h] Q 8 [l/min] 761_A_CH Q [m 3 /h] Q 8 [l/min] 762_A_CH Hc [m] SH [rpm] ISO Annex A 1 1 Q [Imp gpm] Q [US gpm],6, 1,,4 H [ft] Hc [m] SH [rpm] ISO Annex A Q [Imp gpm] Q [US 2gpm],6, 1,,4 H [ft] GEN..D/SHF,3 1,,3 1,,2,2,,,1,1, 8, 2, 8, NPSHr [m] NPSHr [ft] NPSHr [m] 4 4-2/11A φ /1 Ø NPSHr [ft] /1 φ /11 φ Q [m 3 /h] Q 8 [l/min] 763_A_CH Q [m 3 6 /h] Q [l/min] 1 764_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 133
134 GEN..D/SHF SERIES OF BOOSTER SETS (SUCTION LIFT) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT SH [rpm] ISO Annex A SH [rpm] ISO Annex A Q [Imp gpm] Q [Imp gpm] Q [US gpm], Q [US gpm],6 Hc [m], H [ft] Hc [m], H [ft] 1, 1,,4,4,3 1,,3 1,,2,2,,,1,1, 8, 2, 1, NPSHr [m] 4-12/22 φ /4 φ /3 φ /1 Ø NPSHr [ft] NPSHr [m] / φ /1-16/7 Ø 178 φ NPSHr [ft] Q [m1 3 /h] Q 16 [l/min] 76_A_CH Q [m1 3 /h] Q 16 [l/min] 766_A_CH GEN..D/SHF Hc [m] SH [rpm] ISO Annex A Q [Imp gpm] Q [US gpm],6, 1,,4 H [ft] Hc [m] SH [rpm] ISO Annex A Q [Imp gpm] Q [US gpm],6, 1,,4 H [ft],3 1,,3 1,,2,2,,,1,1, 1,, 1, /11A φ NPSHr [m] 4-2/11 φ /1 Ø NPSHr [ft] NPSHr [m] 4-2/1 φ /1 Ø NPSHr [ft] 1-2/22 φ 2-2/18 φ Q [m1 3 /h] Q 16 [l/min] 767_A_CH Q [m1 3 /h] Q 16 [l/min] 768_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 134
135 GEN..D/SHF SERIES OF BOOSTER SETS (SUCTION LIFT) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT SH [rpm] ISO Annex A SH [rpm] ISO Annex A Q [Imp gpm] Q [US 6 gpm], Q [Imp gpm] Q [US 6 gpm],6 Hc [m], H [ft] Hc [m], H [ft] 1, 1,,4,4,3 1,,3 1,,2,2,,,1,1, 1,, 1, /22 φ NPSHr [m] /4 φ /3 φ /1 Ø NPSHr [ft] NPSHr [m] /1 Ø NPSHr [ft] /11 φ /11A φ Q [m14 3 /h] Q 22 [l/min] 761_A_CH Q [m14 3 /h] Q 22 [l/min] 7611_A_CH Hc [m] SH [rpm] ISO Annex A Q [Imp gpm] Q [US 6 gpm],6, 1,,4 H [ft] Hc [m] SH [rpm] ISO Annex A Q [Imp gpm] Q [US gpm] 7,6, 1,,4 H [ft] GEN..D/SHF,3 1,,3 1,,2,2,,,1,1, 1,, 1, NPSHr [m] /1 φ /1 Ø NPSHr [ft] NPSHr [m] /3 φ /37 φ /1 Ø NPSHr [ft] 6-2/22 φ /18 φ Q [m14 3 /h] Q 22 [l/min] 7612_A_CH Q [m16 3 /h] Q [l/min] 7613_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 13
136 GEN..D/SHF SERIES OF BOOSTER SETS (SUCTION LIFT) Hc PRESSURE SURE DROP CURVE IN SUCTION KIT SH [rpm] ISO Annex A SH [rpm] ISO Annex A Q [Imp gpm] Q [Imp gpm] Q [US gpm], Q [US gpm],6 Hc [m], H [ft] Hc [m], H [ft] 1, 1,,4,4,3 1,,3 1,,2,2,,,1,1, 1,, 1, /1 φ 169x /22 φ NPSHr [m] /1 Ø NPSHr [ft] NPSHr [m] 4 8-2/37 φ /3 6-16/1 φ 21 Ø NPSHr [ft] 8-16/18 φ /1 φ Q [m2 3 /h] Q 4 [l/min] 7614_A_CH Q [m3 3 /h] Q [l/min] 761_A_CH GEN..D/SHF Hc [m] SH [rpm] ISO Annex A Q [Imp gpm] Q [US gpm],6, 1,,4 H [ft],3 1,,2,,1, 1, NPSHr [m] /1 Ø NPSHr [ft] Q [m2 3 /h] Q [l/min] 7616_A_CH The declared performance value are valid for liquids with density ρ = 1. Kg/dm 3 and kinematic viscosity ν = 1 mm 2 /sec. The NPSHr values required for the service pump were obtained in the laboratory. When using them for EN 1284 for fire-fighting systems, increase the value by 1 m. Hc: Pressure drop curve in suction kit. 136
137 ACCESSORIES SORIES ACCESSORIES SORIES 137
138 DIAPHRAGM TANKS The booster sets are ready for installation, directly on the manifold, of 24-litre diaphragm tanks, one for each pump. The sets are also equipped with caps to close off the unused couplings. Larger tanks can also be connected to the unused end of the discharge manifold. For proper sizing of the tank please refer to the technical appendix. Kit featuring the following accessories are available on request: diaphragm tank; on-off ball valve; operating instructions; packaging. DIMENSIONI KIT VASI A MEMBRANA DIAPHRAGM TANK KIT Volume PN DIMENSIONS (mm) Materials Litres bar ø A B Valve Diaphragm Vessel Valve " FF EPDM Painted steel Nickel-plated brass " FF EPDM Painted steel Nickel-plated brass " FF EPDM Painted steel Nickel-plated brass " FF EPDM Painted steel Nickel-plated brass " FF Butyl Stainless steel AISI 316 stainless steel " FF EPDM Painted steel Nickel-plated brass COUNTERFLANGE KIT Counterflange coupling kits made of zinc-plated or stainless steel are available on request. The counterflange kits are equipped with: - N. 2 flanges. - gasket and bolts/screws. THREADED COUNTERFLANGES DIMENSIONI KIT CONTROFLANGE TONDE FI Gcom-vmb-en_c_td ACCESSORIES SORIES KIT DIMENSIONS (mm) HOLES TYPE DN ø C ø A B ø D H ø F N PN 2" Rp " ½ 6 Rp 2 ½ " 8 Rp Gcom-ctf-tonde-f-en_a_td DIMENSIONI KIT CONTROFLANGE TONDE A SALDARE WELD-ON COUNTERFLANGES KIT DIMENSIONS (mm) HOLES TYPE DN ø C ø A B ø D ø F N PN 2" "1/ " " " , " 1 17, " 2 221, " 2 276, " 3 327, Gcom-ctf-tonde-s-en_c_td 138
139 ACCESSORIES SORIES FOR BOOSTER SETS SUCTION SIDE KIT The EN 1284 fire-fighting booster sets are supplied without valves and stubs on the suction side of the service pump and can be completed with suitable kits that depend on legal standards. These requirements are expressed by EN 1284 (chapter 1. and chapter 1.6) and are connected with the maximum speed value of the water in the pipes, their minimum section and type of installation - suction lift or positive suction head. To provide for one suction kit for each duty pump. The suction side kit are equipped with: - Anti-vibration joint to attach to the pump inlet. - Eccentric cone or flanged stub pipe. - Vacuum pressure gauge. - On/off butterfly valve (optional in case of positive suction head installation) with lever handle for diameters up to DN1, butterfly valve with handwheel and reduction manual gear for DN12 and higher. Device for monitoring ON/OFF status included. Electrical connections by customer. (Valve lock kit available on request). - Weld-on flange. The following table summarises the pump type installed on the fire-fighting sets and the kit that corresponds to the installation type. ACCESSORIES SORIES 139
140 GEN../ SERIES OF FIRE-FIGHTING BOOSTER SETS SUCTION SIDE KIT DIMENSIONS TABLE ACCESSORIES SORIES SUCTION DIMENSIONS KIT L (mm) TYPE DNS PN DNA PN H (mm) Type 1 Type 2 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Dimensions in mm. Tolerance ± 1 mm. kit-asp2-en_a_td 14
141 GEN../FHF 32-8 SERIES FIRE-FIGHTING BOOSTER SETS SUCTION SIDE KIT DIMENSIONS TABLE SUCTION LIFT POSITIVE SUCTION HEAD RISK SUCTION RISK SUCTION RISK SUCTION RISK SUCTION PUMP CLASS * KIT CLASS * KIT CLASS * KIT CLASS * KIT TYPE TYPE TYPE TYPE FHF 32-12/7 LH 6 X - - LH 8 X - - FHF 32-12/11 LH 6 X - - LH 8 X - - FHF 32-16/1 LH 6 X - - LH 8 X - - FHF 32-16/22 LH 6 X - - LH 8 X - - FHF 32-2/3 LH 6 X - - LH 8 X - - FHF 32-2/4 LH 6 X - - LH 8 X - - FHF 4-12/11 OH1 8 X OH1 1 X FHF 4-12/1 OH1 8 X OH1 1 X FHF 4-12/22 OH1 8 X OH1 1 X FHF 4-16/3 OH1 8 X OH1 1 X FHF 4-16/4 OH1 8 X OH1 1 X FHF 4-2/ OH1 8 X OH1 1 X FHF 4-2/7 OH1 8 X OH1 1 X FHF 4-2/11A OH1 8 X OH1 1 X FHF 4-2/11 OH1 8 X OH1 1 X FHF 4-2/1 OH1 8 X OH1 1 X FHF -12/22 OH2 1 X OH2 12 X FHF -12/3 OH2 1 X OH2 12 X FHF -12/4 OH3 12 X 6 OH2 1 X 6 OH3 1 X 6 OH2 12 X 6 FHF -16/ OH3 12 X 6 OH2 1 X 6 OH3 1 X 6 OH2 12 X 6 FHF -16/7 OH3 12 X 6 OH2 1 X 6 OH3 1 X 6 OH2 12 X 6 FHF -2/11A OH3 12 X 6 OH2 1 X 6 OH3 1 X 6 OH2 12 X 6 FHF -2/11 OH3 12 X 6 OH2 1 X 6 OH3 1 X 6 OH2 12 X 6 FHF -2/1 OH3 12 X 6 OH2 1 X 6 OH3 1 X 6 OH2 12 X 6 FHF -2/18 OH3 12 X 6 OH2 1 X 6 OH3 1 X 6 OH2 12 X 6 FHF -2/22 OH3 12 X 6 OH2 1 X 6 OH3 1 X 6 OH2 12 X 6 FHF 6-12/4 OH3 12 X OH3 1 X FHF 6-12/ OH3 12 X OH3 1 X FHF 6-12/7 OH3 12 X OH3 1 X FHF 6-16/11A OH4 1 X 8 OH3 12 X 8 OH4 2 X 8 OH3 1 X 8 FHF 6-16/11 OH4 1 X 8 OH3 12 X 8 OH4 2 X 8 OH3 1 X 8 FHF 6-16/1 OH4 1 X 8 OH3 12 X 8 OH4 2 X 8 OH3 1 X 8 FHF 6-2/1 OH4 1 X 8 OH3 12 X 8 OH4 2 X 8 OH3 1 X 8 FHF 6-2/18 OH4 1 X 8 OH3 12 X 8 OH4 2 X 8 OH3 1 X 8 FHF 6-2/22 OH4 1 X 8 OH3 12 X 8 OH4 2 X 8 OH3 1 X 8 FHF 6-2/22 OH4 1 X 8 OH3 12 X 8 OH4 2 X 8 OH3 1 X 8 FHF 6-2/3 OH4 1 X 8 OH3 12 X 8 OH4 2 X 8 OH3 1 X 8 FHF 6-2/37 OH4 1 X 8 OH3 12 X 8 OH4 2 X 8 OH3 1 X 8 FHF 8-16/1 HH1 2 X 1 OH4 1 X 1 HH1 2 X 1 OH4 2 X 1 FHF 8-16/18 HH1 2 X 1 OH4 1 X 1 HH1 2 X 1 OH4 2 X 1 FHF 8-2/22 HH1 2 X 1 OH4 1 X 1 HH1 2 X 1 OH4 2 X 1 FHF 8-2/3 HH1 2 X 1 OH4 1 X 1 HH1 2 X 1 OH4 2 X 1 FHF 8-2/37 HH1 2 X 1 OH4 1 X 1 HH1 2 X 1 OH4 2 X 1 FHF 8-2/4 HH1 2 X 1 OH4 1 X 1 HH1 2 X 1 OH4 2 X 1 FHF 8-2/ HH1 2 X 1 OH4 1 X 1 HH1 2 X 1 OH4 2 X 1 * For the risk classes refer to para 6, UNI EN1284. kit-asp-fhf-en_b_td - the pumps must be chosen according to the performance levels indicated in Tab. 6 para 7.3.1, Tab.7 para and the classes of risk. - some pump models can satisfy the conditions of one or more classes of risk. - always check the correct selection of the pump depending on the performance level of the set. ** Insert the mm minimal thickness under the GEN1 fire-fighting booster sets only. ACCESSORIES SORIES 141
142 GEN../FHF 1-12 SERIES FIRE-FIGHTING BOOSTER SETS SUCTION SIDE KIT DIMENSIONS TABLE SUCTION LIFT POSITIVE SUCTION HEAD RISK SUCTION RISK SUCTION RISK SUCTION RISK SUCTION PUMP CLASS * KIT CLASS * KIT CLASS * KIT CLASS * KIT TYPE TYPE TYPE TYPE FHF 1-16/18 HH3 2 X 12 HH2 2 X 12 HH3 2 X 12 HH2 2 X 12 FHF 1-16/22 HH4 2 X 12 HH3 2 X 12 HH4 3 X 12** HH3 2 X 12 FHF 1-16/3 HH4 2 X 12 HH3 2 X 12 HH4 3 X 12** HH3 2 X 12 FHF 1-2/18 HH3 2 X 12** HH2 2 X 12** HH3 2 X 12** HH2 2 X 12** FHF 1-2/3 HH3 2 X 12** HH2 2 X 12** HH3 2 X 12** HH2 2 X 12** FHF 1-2/37 HH4 2 X 12** HH3 2 X 12** HH4 3 X 12** HH3 2 X 12** FHF 1-2/4 HH4 2 X 12 HH3 2 X 12 HH4 3 X 12** HH3 2 X 12 FHF 1-2/3 HH3 2 X 12 HH2 2 X 12 HH3 2 X 12 HH2 2 X 12 FHF 1-2/4 HH4 2 X 12 HH3 2 X 12 HH4 3 X 12** HH3 2 X 12 FHF 1-2/ HH4 2 X 12 HH3 2 X 12 HH4 3 X 12 HH3 2 X 12 FHF 1-2/7 HH 3 X 12 HH4 2 X 12 HH 3 X 12 HH4 3 X 12 FHF 1-2/9 HH6 3 X 12 HH 3 X 12 HH6 3 X 12 HH 3 X 12 FHF 12-2/3 HH7 3 X 1 HH6 3 X 1 HH7 3 X 1 HH6 3 X 1 FHF 12-2/4 HH9 3 X 1 HH8 3 X 1 HH9 4 X 1** HH8 3 X 1** FHF 12-2/ HH1 3 X 1** HH9 3 X 1 HH1 4 X 1** HH9 4 X 1** FHF 12-27/7 HH1 3 X 1 HH9 3 X 1 HH1 4 X 1 HH9 4 X 1 FHF 12-27/9 HH1 3 X 1 HH9 3 X 1 HH1 4 X 1 HH9 4 X 1 FHF 12-27/11 HH1 3 X 1 HH9 3 X 1 HH1 4 X 1 HH9 4 X 1 FHF 12-27/132 HH1 3 X 1 HH9 3 X 1 HH1 4 X 1 HH9 4 X 1 * For the risk classes refer to para 6, UNI EN1284. kit-asp-fhf1-en_a_td - the pumps must be chosen according to the performance levels indicated in Tab. 6 para 7.3.1, Tab. 7 para and the classes of risk. - some pump models can satisfy the conditions of one or more classes of risk. - always check the correct selection of the pump depending on the performance level of the set. ** Insert the mm minimal thickness under the GEN1 fire-fighting booster sets only. ACCESSORIES SORIES 142
143 GEN../SHF 32-8 SERIES FIRE-FIGHTING BOOSTER SETS SUCTION SIDE KIT DIMENSIONS TABLE SUCTION LIFT POSITIVE SUCTION HEAD RISK SUCTION RISK SUCTION RISK SUCTION RISK SUCTION PUMP CLASS * KIT CLASS * KIT CLASS * KIT CLASS * KIT TYPE TYPE TYPE TYPE SHF 32-12/7 LH 6 X - - LH 8 X - - SHF 32-12/11 LH 6 X - - LH 8 X - - SHF 32-16/1 LH 6 X - - LH 8 X - - SHF 32-16/22 LH 6 X - - LH 8 X - - SHF 32-2/3 LH 6 X - - LH 8 X - - SHF 32-2/4 LH 6 X - - LH 8 X - - SHF 32-2/ LH 6 X - - LH 8 X - - SHF 32-2/7 LH 6 X - - LH 8 X - - SHF 32-2/11 LH 6 X - - LH 8 X - - SHF 4-12/11 OH1 8 X OH1 1 X SHF 4-12/1 OH1 8 X OH1 1 X SHF 4-12/22 OH1 8 X OH1 1 X SHF 4-16/3 OH1 8 X OH1 1 X SHF 4-16/4 OH1 8 X OH1 1 X SHF 4-2/ OH1 8 X OH1 1 X SHF 4-2/7 OH1 8 X OH1 1 X SHF 4-2/11A OH1 8 X OH1 1 X SHF 4-2/11 OH1 8 X OH1 1 X SHF 4-2/1 OH1 8 X OH1 1 X SHF -12/22 OH2 1 X OH2 12 X SHF -12/3 OH2 1 X OH2 12 X SHF -12/4 OH3 12 X 6 OH2 1 X 6 OH3 1 X 6 OH2 12 X 6 SHF -16/ OH3 12 X 6 OH2 1 X 6 OH3 1 X 6 OH2 12 X 6 SHF -16/7 OH3 12 X 6 OH2 1 X 6 OH3 1 X 6 OH2 12 X 6 SHF -2/11A OH3 12 X 6 OH2 1 X 6 OH3 1 X 6 OH2 12 X 6 SHF -2/11 OH3 12 X 6 OH2 1 X 6 OH3 1 X 6 OH2 12 X 6 SHF -2/1 OH2 1 X OH2 12 X SHF -2/18 OH3 12 X 6 OH2 1 X 6 OH3 1 X 6 OH2 12 X 6 SHF -2/22 OH3 12 X 6 OH2 1 X 6 OH3 1 X 6 OH2 12 X 6 SHF 6-16/4 OH3 12 X OH3 1 X SHF 6-16/ OH3 12 X OH3 1 X SHF 6-16/7 OH3 12 X OH3 1 X SHF 6-16/11A OH3 12 X OH3 1 X SHF 6-16/11 OH3 12 X OH3 1 X SHF 6-2/1 OH3 12 X OH3 1 X SHF 6-2/18 OH3 12 X OH3 1 X SHF 6-2/22 OH4 1 X 8 OH3 12 X 8 OH4 2 X 8 OH3 1 X 8 SHF 6-2/3 OH4 1 X 8 OH3 12 X 8 OH4 2 X 8 OH3 1 X 8 SHF 6-2/37 OH4 1 X 8 OH3 12 X 8 OH4 2 X 8 OH3 1 X 8 SHF 8-16/11 HH1 2 X 1 OH4 1 X 1 HH1 2 X 1 OH4 2 X 1 SHF 8-16/1 HH1 2 X 1 OH4 1 X 1 HH1 2 X 1 OH4 2 X 1 SHF 8-16/18 HH1 2 X 1 OH4 1 X 1 HH1 2 X 1 OH4 2 X 1 SHF 8-2/22 HH1 2 X 1 OH4 1 X 1 HH1 2 X 1 OH4 2 X 1 SHF 8-2/3 HH1 2 X 1 OH4 1 X 1 HH1 2 X 1 OH4 2 X 1 SHF 8-2/37 HH1 2 X 1 OH4 1 X 1 HH1 2 X 1 OH4 2 X 1 SHF 8-2/4 HH1 2 X 1 OH4 1 X 1 HH1 2 X 1 OH4 2 X 1 SHF 8-2/ HH1 2 X 1 OH4 1 X 1 HH1 2 X 1 OH4 2 X 1 SHF 8-2/7 HH1 2 X 1 OH4 1 X 1 HH1 2 X 1 OH4 2 X 1 * For the risk classes refer to para 6, UNI EN1284. kit-asp-shf-en_a_td - the pumps must be chosen according to the performance levels indicated in Tab. 6 para 7.3.1, Tab. 7 para and the classes of risk. - some pump models can satisfy the conditions of one or more classes of risk. - always check the correct selection of the pump depending on the performance level of the set. ** Insert the mm minimal thickness under the GEN1 fire-fighting booster sets only. ACCESSORIES SORIES 143
144 - + ACCORDING TO EN1284 LAMPS TEST PROVA LAMPADE Plant Type: Tipo impianto: POWER ON PRESENZA TENSIONE UNDER THRESHOLD SOTTO SOGLIA PUMP ON POMPA IN MARCIA INTERRUPTED LINES! 3 LINEE INTERROTTE INCREASE SHIFT ENTER DECREASE / MENU' BUZZER SWITCH OFF TACITAZIONE SIRENA V - + L1/ A A - + L1/ A SPRINKLER DRAINAGE PUMPS ROOM FAULT PUMP L2 L1 L3 JOCKEY PUMP POMPA COMPENSAZIONE Voltage 23 V - -6 Hz Code N Circ. N Battery 12 V 2,3 Ah Buzzer 12Vcc 9mA 7dB(A),2 A IP OVERLOAD SOVRACCARICO SPRINKLER PUMPS ROOM SPRINKLER SALA POMPE PUMP SET ON DEMAND RICHIESTA DI AVVIAMENTO SELECTOR NOT IN AUT. FUNCTION SELETTORE NON IN AUT. V - + L2/ B A L2/ + B L2 PHASE SEQUENCE FAILURE ERRATA SEQUENZA FASE L1 L3 MINIMUM FUEL LEVEL MIN. LIVELLO COMBUSTIBILE!! 1 2 V L3 L3 N.P. START FAILURE MANCATO AVVIAMENTO SWITCHBOARD FAILURE GUASTO QUADRO 1 ELECTRIC PUMP / POMPA ELETTRICA!! OFF OFF 1 2 DIESEL PUMP / MOTOPOMPA MINIMUM LEVEL SUCTION TANK 1 MINIMO LIVELLO VASCA ASPIRAZIONE MINIMUM LEVEL PRIMING TANK 2 MINIMO LIVELLO VASCA ADESCAMENTO! PARTIALLY OPENED SUCTION VALVE OFF VALVOLA IN ASPIRAZIONE NON 1 COMPLETAMENTE APERTA! PARTIALLY OPENED DISCHARGE VALVE OFF VALVOLA IN MANDATA NON 2 COMPLETAMENTE APERTA ALARMS CONTROL ELECTRICAL PANEL Electric panel for remote status and alarm monitoring of one or two Lowara pumps installed in GEN fire-fighting booster sets, according to EN1284. In the electric service pump mode, the following conditions are visualised: - Motor powered. - Pump start-up request. - Pump running - Failure to start. Additionally: minimum suction tank level, minimum priming tank level, on-off valve on suction and discharge side not fully open. The valves are complete with status monitor. In the diesel engine service pump mode, the following conditions are visualised, as required by EN1284: - Switch on diesel engine pump control panel in non-automatic position. - Diesel engine ails to start after 6 attempts. - Pump running - Controller fault. Additionally: minimum fuel or suction tank level, minimum priming tank level, on-off valve on suction and discharge side not fully open. The valves are complete with status monitor. All the above conditions, required by EN1284, are visualised with signal LED s and buzzers. A buzzer alarm reset button and LED tester button are included. ACCESSORIES SORIES The control unit is also fitted out to signal the following general alarms, if present: - General alarm for incorrect electrical connection in the exchange contacts of: flow meter circuit valve, discharge pump, jockey pump status. - Fault in electrical connection in the exchange contact relative to panel 1 (electric pump/diesel engine pump) - Fault in electrical connection in the exchange contact relative to panel 2 (electric pump/diesel engine pump) - Jockey pump overload (*). - Jockey pump running(*) - Discharge pump overload (*). - Battery voltage low. - Communications failure with ModBus system. All the above conditions are visualised with signal LED s and on the display. The customer may decide to enable the buzzer. The panel comprises a plastic casing (IP), battery, battery charger, alarms and pump status display, if connected with 48 serial communication. Fitted to transmit alarms for GSM or PC module. The electric connection between the contacts on the electric alarms control panel and other electric panels is to be seen to by the person installing the equipment. (*) Check that the electric control panel combined with the electric pump is complete with clean contacts for pump running and overload signals. QUADRO TAMPONE ALLARMI TECHNICAL SPECIFICATIONS DESCRIPTION VALUE Input voltage (single-phase) (1F+N) 23V +/-1%, -6 Hz Absorbed,1A Dimensions 37 x 27 x 16 mm Protection grade IP Battery Hermetic lead Rated battery voltage 12 Vcc Rated battery capacity 2,3 Ah ( uncharged in 2 h) Dimensions of battery 178 x 34 x 66 mm Sound emission levels 7dB Control panel weight 1,kg 1284-qal-en_b_td 37 Type DSRC GA11E+1D! 27 - A! 1 2! 1284_2_D_DD 144
145 FLOW METER KIT The flow meter is supplied as part of the assembly kit. The EN 1284 standard requires the presence of the flow meter for checking the hydraulic performance during the test stage and duration periodic inspections. The suction side kit are equipped with: - Direct reading flow meter. - On/off ball valve for diameters up to 2" inclusive, butterfly valve with lever handle from DN6 to DN1 diameter, butterfly valve with handwheel and reduction manual gear for DN12 diameter and above. Device for monitoring ON/OFF status included. Electrical connections by customer. (Valve lock kit available on request). - Connection piping. The meter is available in various sizes according to the flow of a service pump and suitable for being connected to the offtake of the head manifold. For a correct match, identify the type as shown in the set size tables. The flow meter must be installed, where possible, in a stretch of piping with a steady flow and sufficient back pressure at the discharge outlet. The assembly and the discharge piping towards the tank and discharge outlet are to be seen to by the person installing the equipment. TABELLA SHAPE DIMENSIONALE A KIT_FLUSSIMETRO SHAPE B GRUPPI SHAPE EN1284 C SHAPE D DIMENSIONS (mm) DIMENSIONS (mm) TYPE TYPE DN DNAS SHAPE L H DN DNAS SHAPE L H 32X2P 32 2 A 9 6 1X4P 1 4 B X32P A XP 1 B X4P 32 4 A X6P 1 6 C X2P 4 2 A 1 6 1X8P 1 8 C X32P 4 32 A X D X4P 4 4 A XP 12 B XP 4 A X6P 12 6 C X2P 2 A X8P 12 8 C X32P 32 A X D 34 7 X4P 4 A X D XP A X6P 1 6 C X2P 6 2 B 3 7 1X8P 1 8 C X32P 6 32 B X D X4P 6 4 B X1 1 1 D XP 6 B X2 1 2 D X6P 6 6 C X8P 2 8 C X8P 6 8 C X D X4P 8 4 B X1 2 1 D XP 8 B X2 2 2 D X6P 8 6 C X D X8P 8 8 C X1 2 1 D X D X2 2 2 D _kit_flux-acc-en_a_td ACCESSORIES SORIES 14
146 TABLE OF COMBINATIONS FOR FLOW METER KIT AND FHF SERVICE PUMP SERIES TYPE COMBINATION TYPE COMBINATION FHF.. FLOW METER KIT FHF.. FLOW METER KIT ELECTRIC PUMP GEN.. ELECTRIC PUMP GEN.. PUMP D 1D 1D 11D PUMP D 1D 1D 11D 32-12/ /D119 4X2P 4X2P X2P X2P 6-2/1 6-2/D187 8X8P 8X8P 1X8P 1X8P 32-12/ /D136 4X32P 4X32P X32P X32P 6-2/18 6-2/D198 8X8P 8X8P 1X8P 1X8P 32-16/ /D1 4X32P 4X32P X32P X32P 6-2/22 6-2/D21 8X8P 8X8P 1X8P 1X8P 32-16/ /D164 4X32P 4X32P X32P X32P 6-2/22 6-2/D22 8X8P 8X8P 1X8P 1X8P 32-2/3 32-2/D188 4X32P 4X32P X32P X32P 6-2/3 6-2/D241 8X8P 8X8P 1X8P 1X8P 32-2/4 32-2/D24 4X32P 4X32P X32P X32P 6-2/37 6-2/D28 8X8P 8X8P 1X8P 1X8P 4-12/ /D112 6X4P 6X4P 6X4P 6X4P 8-16/1 8-16/D163 1X8P 1X8P 12X8P 12X8P 4-12/1 4-12/D122 6X4P 6X4P 6X4P 6X4P 8-16/ /D173 1X12 1X12 12X12 12X / /D143 6XP 6XP 6XP 6XP 8-2/22 8-2/D189 1X8P 1X8P 12X8P 12X8P 4-16/3 4-16/D19 6X4P 6X4P 6X4P 6X4P 8-2/3 8-2/D27 1X12 1X12 12X12 12X /4 4-16/D171 6XP 6XP 6XP 6XP 8-2/37 8-2/D22 1X8P 1X8P 12X8P 12X8P 4-2/ 4-2/D19 6X4P 6X4P 6X4P 6X4P 8-2/4 8-2/D238 1X12 1X12 12X12 12X12 4-2/7 4-2/D29 6XP 6XP 6XP 6XP 8-2/ 8-2/D26 1X12 1X12 12X12 12X12 4-2/11A 4-2/D218 6XP 6XP 6XP 6XP 1-16/ /D1 12X12 12X12 1X12 1X12 4-2/11 4-2/D233 6XP 6XP 6XP 6XP 1-16/ /D16 12X12 12X12 1X12 1X12 4-2/1 4-2/D21 6XP 6XP 6XP 6XP 1-16/3 1-16/D18 12X1 12X1 2X1 2X1-12/22-12/D119 6XP 6XP 8XP 8XP 1-2/18 1-2/D168 12X12 12X12 1X12 1X12-12/3-12/D13 6X6P 6X6P 8X6P 8X6P 1-2/3 1-2/D192 12X12 12X12 1X12 1X12-12/4-12/D139 6X6P 6X6P 8X6P 8X6P 1-2/37 1-2/D23 12X12 12X12 1X12 1X12-16/ -16/D18 6X6P 6X6P 8X6P 8X6P 1-2/4 1-2/D213 12X12 12X12 2X12 2X12-16/7-16/D174 6X6P 6X6P 8X6P 8X6P 1-2/3 1-2/D2 12X12 12X12 1X12 1X12-2/11A -2/D197 6X6P 6X6P 8X6P 8X6P 1-2/4 1-2/D221 12X12 12X12 2X12 2X12-2/11-2/D29 6X6P 6X6P 8X6P 8X6P 1-2/ 1-2/D23 12X12 12X12 2X12 2X12-2/1-2/D224 6X6P 6X6P 8X6P 8X6P 1-2/7 1-2/D24 12X1 12X1 2X1 2X1-2/18-2/D237 6X6P 6X6P 8X6P 8X6P 1-2/9 1-2/D267 12X1 12X1 2X1 2X1-2/22-2/D2 6X6P 6X6P 8X6P 8X6P 12-2/3 12-2/D18 1X1 1X1 2X1 2X1 6-12/4 6-12/D121 8X6P 8X6P 1X6P 1X6P 12-2/4 12-2/D26 1X2 1X2 2X2 2X2 6-12/ 6-12/D129 8X6P 8X6P 1X6P 1X6P 12-2/ 12-2/D216 1X2 1X2 2X2 2X2 6-12/7 6-12/D14 8X6P 8X6P 1X6P 1X6P 12-27/ /D224 1X2 1X2 2X2 2X2 6-16/11A 6-16/D161 8X8P 8X8P 1X8P 1X8P 12-27/ /D237 1X2 1X2 2X2 2X2 6-16/ /D168 8X8P 8X8P 1X8P 1X8P 12-27/ /D23 1X2 1X2 2X2 2X2 6-16/1 6-16/D178 8X8P 8X8P 1X8P 1X8P 12-27/ /D266 1X2 1X2 2X2 2X2 ACCESSORIES SORIES 1284_kit_flux-fhf_D-11D-en_b_th 146
147 TABLE OF COMBINATIONS FOR FLOW METER KIT AND SHF SERVICE PUMP SERIES TYPE COMBINATION TYPE COMBINATION SHF.. FLOW METER KIT SHF.. FLOW METER KIT ELECTRIC PUMP GEN.. ELECTRIC PUMP GEN.. PUMP D 1D 1D 11D PUMP D 1D 1D 11D 32-12/ /D121 4X32P 4X32P X32P X32P -2/11A -2/D197 6X6P 6X6P 8X6P 8X6P 32-12/ /D136 4X32P 4X32P X32P X32P -2/11-2/D29 6X6P 6X6P 8X6P 8X6P 32-16/ /D1 4X32P 4X32P X32P X32P -2/1-2/D224 6X6P 6X6P 8X6P 8X6P 32-16/ /D168 4X32P 4X32P X32P X32P -2/18-2/D237 6X6P 6X6P 8X6P 8X6P 32-2/3 32-2/D188 4X32P 4X32P X32P X32P -2/22-2/D2 6X6P 6X6P 8X6P 8X6P 32-2/4 32-2/D24 4X32P 4X32P X32P X32P 6-16/4 6-16/D119 8X6P 8X6P 1X6P 1X6P 32-2/ 32-2/D222 4X32P 4X32P X32P X32P 6-16/ 6-16/D129 8X6P 8X6P 1X6P 1X6P 32-2/7 32-2/D242 4X32P 4X32P X32P X32P 6-16/7 6-16/D137 8X6P 8X6P 1X6P 1X6P 32-2/ /D26 4X32P 4X32P X32P X32P 6-16/11A 6-16/D168 8X6P 8X6P 1X6P 1X6P 4-12/ /D112 6X4P 6X4P 6X4P 6X4P 6-16/ /D177 8X6P 8X6P 1X6P 1X6P 4-12/1 4-12/D126 6X4P 6X4P 6X4P 6X4P 6-2/1 6-2/D192 8X6P 8X6P 1X6P 1X6P 4-12/ /D143 6X4P 6X4P 6X4P 6X4P 6-2/18 6-2/D23 8X6P 8X6P 1X6P 1X6P 4-16/3 4-16/D19 6X4P 6X4P 6X4P 6X4P 6-2/22 6-2/D21 8X8P 8X8P 1X8P 1X8P 4-16/4 4-16/D171 6XP 6XP 6XP 6XP 6-2/3 6-2/D24 8X8P 8X8P 1X8P 1X8P 4-2/ 4-2/D19 6XP 6XP 6XP 6XP 6-2/37 6-2/D2 8X8P 8X8P 1X8P 1X8P 4-2/7 4-2/D29 6XP 6XP 6XP 6XP 8-16/ /D169 1X8P 1X8P 12X8P 12X8P 4-2/11A 4-2/D218 6X4P 6X4P 6X4P 6X4P 8-16/1 8-16/D177 1X8P 1X8P 12X8P 12X8P 4-2/11 4-2/D233 6X4P 6X4P 6X4P 6X4P 8-16/ /D186 1X12 1X12 12X12 12X12 4-2/1 4-2/D21 6XP 6XP 6XP 6XP 8-2/22 8-2/D198 1X12 1X12 12X12 12X12-12/22-12/D119 6XP 6XP 8XP 8XP 8-2/3 8-2/D21 1X12 1X12 12X12 12X12-12/3-12/D13 6X6P 6X6P 8X6P 8X6P 8-2/37 8-2/D226 1X12 1X12 12X12 12X12-12/4-12/D139 6X6P 6X6P 8X6P 8X6P 8-2/4 8-2/D237 1X12 1X12 12X12 12X12-16/ -16/D18 6X6P 6X6P 8X6P 8X6P 8-2/ 8-2/D22 1X12 1X12 12X12 12X12-16/7-16/D174 6X6P 6X6P 8X6P 8X6P 8-2/7 8-2/D27 1X12 1X12 12X12 12X _kit_flux-shf_D-11D-en_c_th ACCESSORIES SORIES 147
148 PRIMING TANK The priming tank is used in suction lift installations and carries out the function of maintaining the pump body and suction pipe full of water even if there are leaks through the bottom valve. Each pump must have its own independent priming tank, placed at a higher level than the pump. The tank must be connected to a water source for adding water and keeping it full. The diameter of the connecting pipe to the pump depends on the use class. The return piping for re-circulation can be connected to the tank, which must also provide for discharge if it is too full. A level indicator automatically actions the service pump if the level of the tank drops and is not reintegrated. The hydraulic connections must be seen to by the person installing the equipment. The horizontal l tank is made of zinc-plated steel. ACCESSORIES SORIES PRIMING TANK KIT The available accessories kit includes: - Filling and discharge valves, reductions, non-return valve, closing plugs and automatic air discharger. - Float switch tap complete with ring nut for fixing to the hole through the tank. - Level indicator to connect to the electric panel and assembly instruction sheet. Available on request tank support, height 7, 1, 1, 2 cm. Example of connection to the tank and accessories: ACCESSORIES SORIES N DESCRIPTION N DESCRIPTION 1 Pump priming tank 8 Priming supply non return valve 2 Pipe return from pump delivery side 9 Priming supply on-off valve 3 Floating valve 1 Over flow 4 In flow on-off valve 11 Pressure switch In flow 12 Pump 6 Low level switch 13 To trunk main 7 Drain 14 Pipe connection to delivery side of the pump En-acc-adesc-en_b_tc 148
149 ELECTRIC JOCKEY PUMP KIT The jockey pump or compensation pump has the job of keeping the system under pressure and compensating for any small loses without the intervention of the service pumps. In fact, the jockey pump is commanded by an automatic shut-off panel. Should an electric jockey pump of a different size from the standard be required or should it be installed later on sets which are not predisposed, or should non-standard different size requirements be required, it is possible to configure the booster set with just the service pumps and add the electric jockey pump, also later on. The kit includes: - the hydraulic components for installing the electric pump (base, valves, pressure switch). - the pre-chosen electric pump and the relative electric panel. The hydraulic connection to the set can be easily carried out using one of the couplings on the delivery manifold for the membrane tanks using an adaptor. Kits are available for the vertical electric jockey pumps 1SV series and submersed series 2GS, 4GS, 6GS. The diagram illustrates some connection examples: ACCESSORIES SORIES N DESCRIPTION 1 Electric pump 2 Control Box 3 Connection to trunk main 4 Pipe connection to delivery side of the jockey pump To trunk main acc-kit-fil-en_a_tc 149
150 PANEL BRACKET KIT The electric command panels supplied separately, for example in the sets with submersed pumps, are suitable for being mounted on the wall. Universal bracket kit are available, upon request, for supporting the panels; it must be fixed to the floor using blocks. GU_ACC_M1_A_SC HYDRAULIC CONNECTION FOR FIRE-FIGHTING EN 1284 SETS ACCESSORIES SORIES N DESCRIPTION N DESCRIPTION 1 Suction piping kit * Flow meter kit * 2 Delivery manifold 6 Drain 3 Drain 7 Open discharge 4 From priming tank * 8 To trunk main * See the instruction sheets. En-acc-gener-en_a_tc 1
151 ACCESSORIES SORIES NEW RATE OF FLOW INDICATOR < DN1 FLOATS MONITORED VALVES VALVES HYDRO TUBE ACCESSORIES SORIES FLOW METER RATE OF FLOW INDICATOR ELASTIC JOINTS PRESSURE SWITCHS 11
152 PRODUCT DESCRIPTION BY TECHNICAL SPECIFICATIONS Description EN 1284 fire-fighting booster set Series : GEN Model: electric service pump diesel service pump jockey or compensation pump The pump station will comprise the following components: - N 1 electric jockey pump; - N 1 electric service pump;- N 1 backup diesel pump; - One electrical power and control panel for the electric service pump; - One electrical power and control panel for the diesel pump; - One electrical power and control panel for the electric jockey pump; - Components and materials required for perfect operation and assembly; Lowara booster sets are CE-certified and comply with the following directives: - Machinery Directive 26/42/EC. - Low Voltage Directive 26/9/EC. - Electromagnetic Compatibility Directive 24/18/EC. The hydraulic pump complies with the following standard: - ISO 996-A Rotodynamic pumps hydraulic performance acceptance tests. The fire-fighting booster set complies with European standard EN 1284: Fixed fire-fighting installations Automatic sprinkler systems, design, installation and maintenance. Version with automatic switch-off according to UNI 1779 Hydrant systems design, installation and operating. ACCESSORIES SORIES 12
153 PRODUCT DESCRIPTION BY TECHNICAL SPECIFICATIONS Basic version with periodic auto-test, Series GEN..A. Electronic auto-test circuit with weekly programmer in the electrical panel of the service pump. The pump is turned on an kept working for a minute at the previously established time and date. During this interval the check circuit checks that the pressure in the re-circulation circuit closes the pressure switch contact of the pump which is running. In the case of irregularities, the relative auxiliary self-test alarm relay available for remote signalling is activated and memorised. The EN 1284 Standard does not provide for the presence of a self-test circuit but asks for periodic checks to be carried out by the user, hence the periodic self-test function cannot substitute the above checks. For the precalculated HHP and HHS risk class systems and in the integrally calculated systems, the pump must be able to provide, at 14% of rated capacity, a pressure of not less than 7% of the rated pressure of the pump. Each pump generally backs up the other even if much depends on the chosen type of water supply. If the service pump fails, or a blackout occurs, system pressure will decrease and the backup diesel pump will start. The pumps are started automatically by the pressure switches while they are manually stopped from the electrical panel (key switch). Fire-fighting set components: electric pump Electric service pump comprising: End-suction horizontal centrifugal pump, model FHF..., single impeller, with cast iron body and AISI316L stainless steel shaft. End suction and radial discharge ports. Impeller in AISI316L stainless steel or cast iron. Hydraulic sizes and nominal diameter DN of suction and discharge ports according to EN 733 (ex DIN 242). Flanging to EN (formerly UNI2236) and DIN232. Maximum running pressure: 12 bar. Mechanical seal according to EN1276 (formerly DIN 2496) in Ceramic/Carbon/NBR lubricated with recirculation duct between discharge and seal housing. The pump is directly coupled to the respective motor with an elastic spacer joint ( back pull out version) and alignment and anchor base. B3 three-phase electric motor with short circuit squirrel cage, totally enclosed, fan-cooled. The performance levels of the electric motors lie within what is usually referred to as efficiency class 1. Protected to IP, insulation class F. ACCESSORIES SORIES 13
154 PRODUCT DESCRIPTION BY TECHNICAL SPECIFICATIONS Main characteristics of the electric service pump: TABELLA MATERIALI POMPA SERVIZIO FHF PER CAPITOLATI TECNICI Brand Model: Flow rate Head: Pump body: Seal housing: Impeller: Shaft: Elastomers: Mechanical seal: Motor power: LOWARA FHF Cast iron, EN 161-GJL-2 (JL13) Cast iron, EN 161-GJL-2 (JL13) Cast iron, EN 161-GJL-2 (JL13) Stainless steel EN188-1-X2 CrNiMo NBR Ceramic/Carbon/NBR m3/h m.c.a. Kw Input voltage: 4 / 3 V Frequency: Hz Rated current input: A Speed of rotation: 29 r.p.m. Max. ambient temp: 4 ºC Protection class: Insulation class: IP F tec_fhf-en_b_tm Backup up diesel engine pump comprising: Normalised horizontal centrifugal pump, FHF... according to EN 733 (ex DIN 242) max. operating pressure PN12. End suction and radial discharge ports. Impeller in AISI316L stainless steel or cast iron, mechanical seal in Ceramic/Carbon/NBR lubricated with recirculation duct between the discharge and the seal housing according to EN1276 (formerly DIN 2496). Main components of the diesel engine pump: - Electrical panel with battery charger. - Diesel engine start circuit with two independent batteries. ACCESSORIES SORIES - Double engine starting relay. - Engine shut-off device from electric control (Electric stop). - Fuel tank for diesel engine equipped with float - Diesel engine coupled to service pump. - Base made of structural steel with epoxy powder painting RAL 1. The diesel pump is supplied on its own base complete with vibration-proof feet, wall-mounted electrical panel fixed to the bracket of the set complete with 3-metre long cable ( metres available on request) wall- or floor-mounted fuel tank depending on capacity, pair of batteries lying on base with three metres of electrical cable for positioning by the final user near the diesel engine. 14
155 PRODUCT DESCRIPTION BY TECHNICAL SPECIFICATIONS Main characteristics of the diesel engine service pump: TABELLA MATERIALI MOTOPOMPA SERVIZIO FHF PER CAPITOLATI TECNICI Brand: LOWARA Model: DFHF Flow rate: m3/h Head: m.c.a. Pump body: Cast iron, EN 161-GJL-2 (JL13) Seal housing: Cast iron, EN 161-GJL-2 (JL13) Impeller: Cast iron, EN 161-GJL-2 (JL13) Shaft: Stainless stee EN188-1-X2 CrNiMo Elastomers: NBR Mechanical seal: Ceramic/Carbon/NBR Diesel engine motor power: Kw Motor speed: 3 r.p.m. Max. ambient temp.: 4 ºC Diesel fuel tank capacity: l tec_dfhfe-en_b_tm Electric jockey ey pump comprising: Multi-cell vertical centrifugal Jockey pump, 1SV... with metal parts in contact with liquid in stainless steel, pump body and shaft in AISI 34 stainless steel, impeller in AISI 34 stainless steel, mechanical seal in Carburundum/ carbon/epdm. Three-phase electric motor, shape B14, performance values within what is referred to as efficiency class 2, short circuit squirrel cage motor, closed aluminium casing and external ventilation, performance according to EN 634-1, directly coupled to the vertical pump. Protected to IP, insulation class F. ACCESSORIES SORIES 1
156 PRODUCT DESCRIPTION BY TECHNICAL SPECIFICATIONS Main technical characteristics of the jockey pump: TABELLA MATERIALI POMPA SERVIZIO SV PER CAPITOLATI TECNICI Brand: Model: Flow rate: Head: Pump body: Impeller: Diffuser: Shaft: Outer sleeve: Mechanical seal: Motor power: Stainless steel (1.431) Stainless steel (1.431) Stainless steel (1.431) Stainless steel (1.431) Stainless steel (1.431) Silicon carbide/carbon/epdm LOWARA 1SV m3/h m.c.a. Kw Input voltage: 4 / 3 V Frequency: Hz Rated current: A Speed: 29 r.p.m. Max. ambient temp.: 4 ºC Protection class: Insulation class: IP - F tec_sv-en_b_tm Electric panels Electric service pump panel Painted metal casing (IP4) complete with: ACCESSORIES SORIES - General door-locking switch. - Analogical ammeter. - MAN AUT selector with extractable key only in automatic position. - Keyboard for indicating electric voltage presence, correct phase sequence (three phase power supply), start-up request, pump functioning and no start-up, through LED lamps, lamp test button and starting and stopping buttons, according to the provisions of EN1284 paragraph Inside: - 12/24V transformer for auxiliary circuits and electronic board. - Fuse holder and fuses for power and auxiliary circuits. 16
157 PRODUCT DESCRIPTION BY TECHNICAL SPECIFICATIONS - Line contact maker (direct start-up), line and star/delta contact makers (star/delta start-up), line contact makers and reactance switching (impedance start-up). - Star/delta exchanger timer or reactance switching. - Relay for signalling no phase. - Auxiliary relays. - Current transformer. - Terminal boards. - Clean contacts (max 24V, 1A) for activating acoustic/ visual alarms for no phase, pump on demand, pump running and start failure. - Cable glands (excluding the versions to be fixed to the floor). - Wiring diagram. Jockey pump electrical panel Painted metal casing (IP) complete with: - General door-locking switch. - Visual indicators for line, running, thermal shutdown. - Manual automatic selector excluded. Inside: - Transformer for auxiliary circuits at 24 V. - Fuse holder and fuses for power and auxiliary circuits. - Line contact maker. - Overload cut-out switch. - Pump shut-off timer ( 9 s). - Terminal boards. - Cable glands. - Wiring diagram. Suitable for connecting to a float switch or a minimum pressure switch for preventing dry running. An optional level control module (supplied upon request) allows the connection of probes with the possibility of regulating the sensitivity according to the hardness of the water. Control panel for diesel engine pump Painted metal casing (IP4) complete with: - General door-locking switch. Electronic unit for control and management of the diesel engine. Display of alarms and status, battery voltage, speedometer, hour counter, alarm programming, date display, main signals and manual start button. ACCESSORIES SORIES 17
158 PRODUCT DESCRIPTION BY TECHNICAL SPECIFICATIONS - MAN AUT selector with extractable key only in automatic position. - Pair of emergency battery start buttons. Inside: - Fuse holder and fuses for power and auxiliary circuits. - Pair of battery chargers 12Vdc/24Vdc. - Control unit for management of diesel engine and alarms. - Auxiliary relays. - Power circuits for engine heaters. - Terminal boards. - RS232 connector for communication port. - Cable glands. - Wiring diagram. The panel is supplied standard with dry alarm signal contacts (max 1ª, 3Vdc/12vac/277Vac): ac): - Non-automatic operating mode. - Controller fault. - Motor running. - Failure to start. - General alarm. Standard single-phase input voltage 1 x 23V. Series of clean contacts for checking the status of the electric service pump panel, as well as the contacts already provided for signalling alarms (on request): ACCESSORIES SORIES - No phase. - Motor running.. - Selector position Man-Aut-. - Failure to start. - Start-up request. Series of clean contacts for checking the status of the electric jockey pump (on request) - Pump running. - Thermal shutdown (overload). - No water. Electrical alarms panel Plastic casing protected to IP with an electronic board at the front for the visual and acoustic signalling of the status of one or two service pumps. The following alarms are signalled : 18
159 - + ACCORDING TO EN1284 LAMPS TEST PROVA LAMPADE Plant Type: Tipo impianto: POWER ON PRESENZA TENSIONE UNDER THRESHOLD SOTTO SOGLIA PUMP ON POMPA IN MARCIA INTERRUPTED LINES! 3 LINEE INTERROTTE INCREASE SHIFT ENTER DECREASE / MENU' BUZZER SWITCH OFF TACITAZIONE SIRENA V - + L1/ A A - + L1/ A SPRINKLER DRAINAGE PUMPS ROOM FAULT PUMP L2 L1 L3 JOCKEY PUMP POMPA COMPENSAZIONE Voltage 23 V - -6 Hz Code N Circ. N Battery 12 V 2,3 Ah Buzzer 12Vcc 9mA 7dB(A),2 A IP OVERLOAD SOVRACCARICO SPRINKLER PUMPS ROOM SPRINKLER SALA POMPE PUMP SET ON DEMAND RICHIESTA DI AVVIAMENTO SELECTOR NOT IN AUT. FUNCTION SELETTORE NON IN AUT. V - + L2/ B A L2/ + B L2 PHASE SEQUENCE FAILURE ERRATA SEQUENZA FASE L1 L3 MINIMUM FUEL LEVEL MIN. LIVELLO COMBUSTIBILE!! 1 2 V L3 L3 N.P. START FAILURE MANCATO AVVIAMENTO SWITCHBOARD FAILURE GUASTO QUADRO 1 ELECTRIC PUMP / POMPA ELETTRICA!! OFF OFF 1 2 DIESEL PUMP / MOTOPOMPA MINIMUM LEVEL SUCTION TANK 1 MINIMO LIVELLO VASCA ASPIRAZIONE MINIMUM LEVEL PRIMING TANK 2 MINIMO LIVELLO VASCA ADESCAMENTO! PARTIALLY OPENED SUCTION VALVE OFF VALVOLA IN ASPIRAZIONE NON 1 COMPLETAMENTE APERTA! PARTIALLY OPENED DISCHARGE VALVE OFF VALVOLA IN MANDATA NON 2 COMPLETAMENTE APERTA PRODUCT DESCRIPTION BY TECHNICAL SPECIFICATIONS Electric pump Power off. Start-up request. Pump running. No start-up. Diesel pump Non-automatic. Controller fault. Pump running. No start-up. The electric panel is fitted with a buzzer with reset button, signal LED test button, battery charger and battery and is fitted out to signal the following general alarms, if present: - General alarm for incorrect electrical connection in the exchange contacts of: status of flow measurement circuit valve, drain pump, jockey pump. - Fault in electrical connection in the exchange contact relative to panel 1 (electric pump/diesel engine pump). - Fault in electrical connection in the exchange contact relative to panel 2 (electric pump/diesel engine pump). - Jockey pump overload. - Jockey pump running. - Discharge pump overload. - Battery voltage low. - Communications failure with ModBus system. GSM modem system status transmission module and RS232/48 converter module available on request. QUADRO TAMPONE ALLARMI TECHNICAL SPECIFICATIONS 27 DESCRIPTION VALUE Input voltage (single-phase) (1F+N) 23V +/-1%, -6 Hz Absorbed,1A Dimensions 37 x 27 x 16 mm Protection grade IP Battery Hermetic lead Rated battery voltage 12 Vcc Rated battery capacity 2,3 Ah ( uncharged in 2 h) Dimensions of battery 178 x 34 x 66 mm Sound emission levels 7dB Control panel weight 1,kg Control instruments and hydraulic accessories The main components of the sets are: 1284-qal-en_b_td - On/off valves on the delivery side of each pump, ball valves with lever handle for diameters up to 11/4" inclusive, butterfly valve with lever handle from DN6 to DN1 diameter, butterfly valve with handwheel and reduction manual gear for DN12 diameter and above. - Re-circulation device for each service pump. The re-circulation device allows a minimum capacity in order to prevent the pump overheating when working with closed delivery. It includes the activation pressure switch for the alarms of the pumps running, the test valve for checking the seal of the check valves, the couplings for any connecting pipes to the priming tank in the case of suction lift installation. The connection of each re-circulation to the suction tank or the priming tank is to be seen to by the person installing the equipment. 37 Type DSRC GA11E+1D! - A! 1 2! 1284_2_D_DD ACCESSORIES SORIES 19
160 PRODUCT DESCRIPTION BY TECHNICAL SPECIFICATIONS - Pressure gauge on the delivery side of each service pump between check valve and on/off valve. - Check valve be inspected type, on the delivery side of each pump. Threaded connector up to and including a diameter of 11/4". Flanged connector for larger diameters. - Painted iron delivery manifold (PN 16) and threaded stubs with relative caps for connecting any 24 litre membrane tanks. Blind and welding zinc-plated flanges. - Two start-up pressure switches for every service pump. For the electric service pumps, start-up takes place through the pressure switch, but it must be manually stopped using the key-operated selector switch on the panel (excluding the version with automatic shut-off). For the electric jockey pump, if present, both start-up and stopping are determined by the pressure switch. - Start-up pressure switch circuit for the service pump, including connecting pipes for the delivery manifold, recirculation circuit. This circuit includes on/off valve, a non-return valve, a discharge or test valve and various pipe fittings. The configuration of the circuit allows the pressure switch to intervene also when the relative on/off valve is closed. - Various pipe fittings (copper, zinc-plated steel). - Base made of bent sheet or structural iron with epoxy powder painting RAL 1. - Control panel frame made of structural iron with epoxy powder painting RAL 1. The control panels for the electric pumps up to kw power supply are fixed on bracket. For higher powers, the control panels for electric pump service are floor mounted, instead the jockey electric pump panel is wall mounted fixed. - Diesel engine with coupling to service pump. - Vibration-damping joints on discharge side. - Electric panel for control of diesel engine pump and battery charger. ACCESSORIES SORIES - Diesel engine start circuit with two independent batteries. - Double engine starting relay. - Engine shut-off device from electric control (electric stop). - Fuel tank for diesel engine. 16
161 PRODUCT DESCRIPTION BY TECHNICAL SPECIFICATIONS - Electric panel for each electric service pump. The diesel engine pump is mounted on its own base complete with vibration-damping feet, and comes with a wall-mounted electric panel fitted with 3-metre cables ( metre length available on request), fuel tank with wall or floor mounting depending on capacity, floor-mounted batteries with iron frame to position to the side of the diesel engine. The installation of the diesel engine must provide for adequate ventilation and exhaust of combustion fumes. Flow meter The flow meter is supplied as part of the assembly kit. The EN 1284 standard requires the presence of the flow meter for checking the hydraulic performance during the test stage and duration periodic inspections. The kit comprises: - Direct reading flow meter. - On/off ball valve for diameters up to 2 inclusive, butterfly valve with lever handle from DN6 to DN1 diameter, butterfly valve with handwheel and reduction manual gear for DN12 diameter and above. - Straight plastic connection piping. IThe flow meter is available in various sizes according to the flow of a service pump and suitable for being connected to the offtake of the head manifold. For a correct match, identify the type as shown in the set size tables. The assembly and the discharge piping towards the tank and discharge outlet are to be seen to by the person installing the equipment. The following illustration shows the type and size of flow meter: Dimensions (mm): DN = DNAS = L = H = Qmax (m 3 /h) = ACCESSORIES SORIES 161
162 PRODUCT DESCRIPTION BY TECHNICAL SPECIFICATIONS Diaphragm tanks The booster sets are ready for installation, directly on the manifold, of 24-litre diaphragm tanks, one for each pump. The sets are also equipped with caps to close off the unused couplings. Larger tanks can also be connected to the unused end of the discharge manifold. The kit is made up of the following accessories: - Diaphragm tank; - On-off ball valve; - Instructions manual; - Packaging. Suction kit The EN 1284 fire-fighting booster sets are supplied without valves and stubs on the suction side of the service pump and can be completed with suitable kits that depend on legal standards. These requirements are expressed by EN 1284 (chapter 1. and chapter 1.6) and are connected with the maximum speed value of the water in the pipes, their minimum section and type of installation - suction lift or positive suction head. To provide for one suction kit for each duty pump. The kit comprises: - Anti-vibration joint to attach to the pump inlet. - On/off butterfly valve (optional in case of positive suction head installation) with lever handle for diameters up to DN1, butterfly valve with handwheel and reduction manual gear for DN12 and higher. - Eccentric cone. - Vacuum pressure gauge. - Weld-on flange. The following illustration shows the suction kit: ACCESSORIES SORIES Dimensions (mm): DNA = L = DNS = H= 162
163 PRODUCT DESCRIPTION BY TECHNICAL SPECIFICATIONS The set is supplied already assembled, calibrated and factory tested. The set is supplied complete with an instruction manual, pump manuals and wiring diagrams for the panels. For the sets including floor panels, the electric panels are sent together with the set in a separate pack and supplied with -metre long connecting cables (longer lengths available on request). The fitter is responsible for preparing the routes and installing the cables. ACCESSORIES SORIES 163
164 FURTHER PRODUCT SELECTION AND DOCUMENTATION TION Xylect Xylect is pump solution selection software with an extensive online database of product information across the entire Lowara, and Vogel range of pumps and related products, with multiple search options and helpful project management facilities. The system holds up-to-date product information on thousands of products and accessories. The possibility to search by applications and the detailed information output given makes it easy to make the optimal selection without having detailed knowledge about the Lowara and Vogel products. The search can be made by: Application Product type Duty point ACCESSORIES SORIES Xylect gives a detailed output: List with search results Performance curves (flow, head, power, efficiency, NPSH) Motor data Dimensional drawings Options Data sheet printouts Document downloads incl dxf files The search by application guides users not familiar with the product range to the right choice. 164
165 FURTHER PRODUCT SELECTION AND DOCUMENTATION TION Xylect The detailed output makes it easy to select the optimal pump from the given alternatives. The best way to work with Xylect is to create a personal account. This makes it possible to: Set own standard units Create and save projects Share projects with other Xylect users Every user have a My Xylect space, where all projects are saved. ACCESSORIES SORIES For more information about Xylect please contact our sales network or visit Dimensional drawings appear on the screen and can be downloaded in dxf format. 16
166 ACCESSORIES SORIES 166
167
168 Xylem 1) The tissue in plants that brings water upward from the roots; 2) a leading global water technology company. We re 12, people unified in a common purpose: creating innovative solutions to meet our world s water needs. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 1 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation. For more information on how Xylem can help you, go to xyleminc.com. Headquarters LOWARA S.r.l. Unipersonale Via Lombardi Montecchio Maggiore - Vicenza - Italy Tel.(+39) Fax(+39) [email protected] web: LOWARA reserves the right to make modification without prior notice. LOWARA is a trademark of Xylem Inc. or one of its subsidiaries.
Fire Pump Plan Review March 2010
Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:
32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw
,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business
Horizontal Split Case Fire Pumpset Diesel Engine Driven
SERIES Horizontal Split Case Fire Pumpset Diesel Engine Driven Selected Models INTRODUCTION Lubi offers LHCD series state-of-the-art fire pumpset with diesel engine driven, horizontal split case pump.
32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw
,QGXVWULDO#*HQHUDWRU 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw Generator set consisting of engine and alternator mounted
DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw
DLW 8 POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw Generator set consisting of engine and alternator mounted on a fabricated steel
FAIRBANKS NIJHUIS FIRE PUMPS. www.fairbanksnijhuis.com
FAIRBANKS NIJHUIS FIRE PUMPS www.fairbanksnijhuis.com FAIRBANKS NIJHUIS Long established as a leading fire pump manufacturer, Fairbanks Nijhuis offers a broad range of horizontal and vertical split case,
LC/LCD ranges level controllers
GRUNDFOS WASTEWATER LC/LCD ranges level controllers 18 Grundfos Sololifts > Grundfos LC/LCD controllers Keeping a close eye on liquid levels Reliable level controllers from Grundfos Grundfos offers a choice
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
ELECTRIC/DIESEL FIRE PUMP CHECK LIST
BUILDING NAME: DESIGNER: SCO REPRESENTATIVE: PUMP MANUF.: LOCATION: INSTALLER: DATE: OWNER NAME: INSTALLATION Certificate for flushing and hydrostatic test furnished Piping been hydrostatically tested
Vertical Multistage Centrifugal Electric Pumps SV2-4-8-16 Series NEW LASER TECHNOLOGY
Vertical Multistage Centrifugal Electric Pumps SV2-4-8-16 Series NEW LASER TECHNOLOGY TYPICAL APPLICATIONS Water supply Transfer and distribution from water systems Pressure boosting in apartment buildings
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS
Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar
50 Hz. GHV20-GHV30-GHV40 Series. VARIABLE-SPEED BOOSTER SETS WITH VERTICAL MULTISTAGE ELECTRIC PUMPS e-sv SERIES. Cod.
Hz GHV2-GHV3-GHV4 Series VARIABLE-SPEED BOOSTER SETS WITH VERTICAL MULTISTAGE ELECTRIC PUMPS e-sv SERIES Cod. 191771 Rev ev.c.c Ed.6/212 CONTENTS General introduction...3 Choice and selection...7 2 GHV.../SV
Conlift1, Conlift2, Conlift2 ph+
GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications
2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS
2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Ergo-Pro Single Line Solar Station Installation and Operating Instructions
Rp 3/4 Ergo-Pro Single Line Solar Station Installation and Operating Instructions Item No Pump type 677.21.70 WILO ST 15/6 13 2 4 11 Technical Specifications Max. operating pressure: 6 bar Max. operating
Hydraulic Control Solutions
Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district
Max. Head (m) LVR3-7-220V 3 32 5 44 0,55 10 50Hz ~ 220 V Oval Flange G1. LVR3-7-380V 3 32 5 44 0,55 10 50Hz ~ 380 V Oval Flange G1
Description NordicFlow s keep the system pressurized during normal conditions and prevent unnecessary activation of the main pump. They have compact design, high efficiency, low noise, reliable sealing
4" SUBMERSIBLE PUMPS
4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant
CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html
SELECTION, APPLICATION AND MAINTENANCE
DIESEL PROTECTION SYSTEMS Automatic Diesel Engine Shut Down System for Safe Area Applications SELECTION, APPLICATION AND MAINTENANCE Series 300 Series 310 SYSTEM DESCRIPTION Suitable for attended engine
Horizontal Split Case Fire Pumpset Electric Motor Driven 50 Hz
SERIES Horizontal Split Case Fire Pumpset Electric Motor Driven 50 Hz Selected Models INTRODUCTION Lubi offers LHCE series state-of-the-art fire pumpset with electric motor driven, horizontal split case
4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves
1. General company and product information 2. Flanged gate valves for water 3. Other gate valves for water 4. Combi valves 5. Service connection valves for water 6. Valves and fittings for gas 7. Fire
Model 1210C Battery Powered Pump Shown. Description
12 Volt DC Rotary Vane Pump Series 1200C Model 1210C Battery Powered Pump Shown Description of Included Models Model Number FR1205C FR1210C FR1211C FR2410C FR2411C Description Basic 12 volt DC pump with
Multistage high-pressure multistage centrifugal pumps
Series description Wilo-Helix V 2 4 6 8 Wilo-Helix V 19-27 7 6 6 Hz - North America 22 2 18 5 16 14 4 12 3 1 V 1 V 19 V 27 8 2 6 1 5 1 15 2 25 3 4 2 35Q[US gpm] H[ft] H[m] Design Vertical multi-stage,
Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank
Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank This specification describes requirements for a Diesel Fuel Day Tank System consisting of one or more fuel tanks, an Electronic
Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version
instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ
GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html
Power consumption (kw)
OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components
1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;
1/11 CO2 DOSAGE SYSTEMS CO2 dosage system consists of following parts; 1 - O2 trim system with micro processing burner (automatic combustion monitoring), 2 - Other components of O2 trim system, 3 - CO2
dp pumps the dynamics of water HVAC centrifugal (norm) pumps
dp pumps the dynamics of water HVAC centrifugal (norm) pumps 2 HVAC centrifugal (norm) pumps HVAC efficient solutions for comfortable living conditions To be comfortable in a building, both at home and
7.1. Part Lists. Hardware Insertion Machine. Instructions. Instructions
Instructions Instructions The Parts in this section of the manual are listed by Item Number, Part Number, Description and Quantity. The Item Numbers are in a circle with an arrow pointing to the specific
SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
Annex-A TECHNICAL SPECIFICATION
Annex-A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 0.4kV (2,000kVA) DIESEL GENERATOR 1 1.0 SCOPE This specification covers the requirements of design, manufacture, delivery
Competency Framework for Marine Engineer Class 6. Competency Framework for Marine Engineer Class 6
Table of Contents (MEC 6)... 1 Function: Operate Vessel Machinery and Systems... 1 Diesel engines.... 1 Operational procedures.... 3 Operate and monitor a vessel s engines and auxiliary equipment.... 4
MEMBRANE VACUUM MINI PUMPS
MEMBRANE VACUUM MINI PUMPS The mini pumps described in this page are membrane-type. They can be used both as vacuum pumps and compressors. In the latter version they can supply compressed air 100% oil-free
Heating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features
Booster Pump Control Valve Quick Active Check Valve Isolates system from the effects of pump starts and stops for: Solitary single speed pumps Battery of single speed pumps (add & switch) Battery of variable
Condensing unit type EPSILON-ECHOS LE Technical information manual
Condensing unit type EPSILON-ECHOS LE Technical information manual 2 > EPSILON ECHOS Water chiller > EPSILON ECHOS /HP Reversible heat pump > EPSILON ECHOS /ST Water chiller with storage tank and pumps
OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.
Our Other Products OUR PRODUCTS Liquid Ring & Rotary Vane Vacuum Pumps and Systems Liquid Ring Vacuum Pumps: 3 CFM to,000 CFM Liquid Ring Compressors up to 1 psig Heat Transfer Pumps for hot thermal oils
Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump
Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum
INLINE SD-PUMPS WITH IEC-STANDARD MOTOR
INLINE SD-PUMPS WITH IEC-STANDARD MOTOR AT_-1/ Hz DN1 3 r/min min H G 1/ G 1/ 17 11 3xM, Depth 1 1 Ø1 Ø1 xø19 7 3xØ1 9 17 1 xø1 17 1 kw A kg H OKN-13 E1 F19 7. (9). 9 OKN-13 C1 F19. (.) 11. 1 9 OKN-1 E1
In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).
DS3002 1. General Description This data sheet describes the Modular Power (MP) Electro Hydraulic Power Units, which have been designed to provide an advanced and flexible means of brake control. The MP
Visions become real. Temperature control and cooling systems. The innovative and reliable solution
Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature
Butterfly Valves PN 6/10/16 for flanged connection
4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40
CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value
Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be
MFP14, MFP14S and MFP14SS Automatic Pumps
Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
How To Pump A Pump
Multistage Pumps P, PVa, MP 300 Technical Data Performance range: m Capacities up to 1800m 3 /h (8800USgpm) m Head up to 300m (1000feet) m Max. speed up to 1750rpm Multistage pumps of series MP with smaller
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Rules for Classification and Construction Additional Rules and Guidelines
VI Rules for Classification and Construction Additional Rules and Guidelines 5 Pumps 1 Guidelines for the Design, Construction and Testing of Pumps Edition 2007 The following Guidelines come into force
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
Magnum Mobile Generator MMG55 Specifications
Empowering Real People Magnum Mobile Generator MMG55 Specifications ENGINE John Deere PE5030TF270 - turbocharged, diesel engine o Prime - 72 hp @ 1800 rpm o Standby - 80 hp @ 1800 rpm o 4 cylinder o 3.0
MARKET SECTORS CIVIL, AGRICULTURAL, INDUSTRIAL.
Twin- Impeller Centrifugal Electric Pumps CA-CA(N) Series Standard supplied IE2 motors are compliant with Regulation (EC) no. 640/2009. MARKET SECTORS CIVIL, AGRICULTURAL, INDUSTRIAL. APPLICATIONS Version
SJT / SJM / SJP Large Vertical Pumps
SJT / SJM / SJP Large Vertical Pumps The Heart of Your Process SJT, SJM, SJP Large Vertical Pumps Product Overview SJT Turbine Ns 1800 < 5000 nq 35 < 110 SJM Mixed Flow Ns 5800 < 8300 nq 113 < 161 SJP
SPP Pumps Inc. Atlanta
SPP Pumps Inc. Atlanta UL Listed, FM Approved Fire Pump Sets Horizontal Split Case Pumps Flows from 200-5000 US GPM Vertical Turbine Flows to 5000 US GPM In-Line Pumps Flows to 750 US GPM End Suction Flows
OLI. Oil level indicator
OLI Oil level indicator Oil level indicator Unexpected or accidental oil leakages may occur randomly along transformer s lifetime. Clear indication of oil level inside transformer tank and on load tap
Assisted lift operated 2/2-way solenoid valves Type EV250B
MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way
solarplus solar systems general features
SOLARPLUS solar systems solarplus Applications: expansion vessels for solar systems Zilmet, an internationally operating company with over 50 years of experience has grown to be the biggest European producer
Automatic Fire Fighting Monitors
Automatic Fire Fighting Monitors Fire Protection Solutions Automatic Fire Fighting Monitors Foreword Automatic monitors are devices used to deliver large amounts of water or water/foam solution to remote
SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS 426 2.98 12.06
SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS LV SIGMA PUMPY HRANICE, s.r.o. Tovární 605, 753 01 Hranice, Czech Republic tel.: +420 581 661 111, fax: +420 581 602 587 Email: [email protected]
BERMAD Fire Protection
400E-2M/700E-2M IOM Bermad Electrically Controlled Deluge Valve with EasyLock Manual Reset Model: 400E-2M/700E-2M INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 400E-2M/700E-2M Bermad
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
MODEL 300505 INSTALLATION INSTRUCTIONS
WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 [email protected] Your pump has been carefully packaged at the factory to prevent damage during shipping.
TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * 41.729.220 Thermostat for CH 12/18
ACCESSORIES RT1, RT2, RT3 IT1 DA1 Thermostat for CH 12/18. Digital timer, burning and ventilating. Fault detector GSM. GSM temperature fault detector. THERMOSTATS RT1, room thermostat -10/+40 C with 5
Photovoltaic Solar Energy Unit EESFB
Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality
PS1800 Centrifugal Pumping Systems
PS1 Centrifugal Pumping Systems General Data and Sizing Tables The curve show the performance range of 4 models at 1Wp solar array - irradiation of 6kWh/m² on a tilted surface - ambient temperature 3 C
Horizontal Jet Pumps 1/3-1-1/2 HP
Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
KNC Model 3666 Automatic Pressure Calibration System
KNC Model 3666 Automatic Pressure Calibration System Product Description The Model 3666 Automatic Pressure Calibration (APC) System by King Nutronics Corporation is a portable secondary standards laboratory
Element D Services Plumbing
Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.
Kompressoren. Adsorption Dryer AD
Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated
FIRE FIGHTING PACKAGES
FIRE FIGHTING PACKAGES UNE 166.002 ISO 14001 0128 A Leader s Response Bombas Ideal S.A. has been manufacturing pumps since 1902. Throughout this period, the most advance technology available has been used
Freezers - Ultrafreezers. Platilab & Irilab Series
Freezers - Ultrafreezers Platilab & Irilab Series PLATILAB: top security and performances with reliable temperature control. IRILAB: combining the high reliability of PLATILAB with the possibility to store
- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401
CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS
Morrison Bros. Co. General Product Specifications
Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.
This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product
TMS TANK MANAGEMENT SYSTEM
TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS
Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty
Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp
TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP
TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:
Power Generation. Power Control PCL System Generator Set Control
Power Generation Power Control PCL System Generator Set Control Solid State Control The Power Control PCL system uses the latest solid state control technology. Designed for the budget-conscious installation
Adsorption air dryers ADS 1 215
Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
VDL 53 - Vacuum drying oven for flammable solvents
Vacuum drying ovens VDL 53 - Vacuum drying oven for flammable solvents The VDL series ensures maximum safety when drying organic solvents in accordance with TÜV/GS guidelines. The interior chamber is designed
Thyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range
Type series booklet 8521.15/2--10 ACTELEC 31 to 800 (BERNARD) 1/4 turn electric actuators (irreversible reducer with multi -turn electric actuator ACTELEC 31: screw -nut kinematics ACTELEC 200 to 800: