IICC Technical Overview
|
|
|
- Jasper Hawkins
- 10 years ago
- Views:
Transcription
1 IICC Technical Overview Ed Heierman CTO, IVD Industry Connectivity Consortium May 2014
2 IICC Mission To create and ensure adoption of an interoperable connectivity paradigm to reduce the complexity and variability of data exchange between IVD testing systems and healthcare informatics systems Laboratory Analytical Workflow (LAW) is the culmination of the technical team s efforts to define the data exchange
3 LAW Profile Developed in partnership with IHE Laboratory Analytical Work Order Steps (AWOS) only Pre (sorters, decappers) and post (cappers, storage) devices covered by Laboratory Device Automation (LDA) Profile Actors Analyzer (Instrument) Analyzer Manager (Middleware, LIS) Transactions LAB-27 Query for AWOS LAB-28 AWOS Broadcast LAB-29 AWOS Status Change
4 LAW Profile Messaging Based on HL7 v2.5.1 Messages Pre-adoption of elements of v2.7, v2.8, and v2.9
5 LAW Use Cases AWOS transfer to the Analyzer before specimen arrival AWOS broadcast by the Analyzer Manager before specimen arrival AWOS query by the Analyzer for ALL specimens before specimen arrival AWOS Query by the Analyzer at specimen arrival AWOS created at the Analyzer Rerun Rerun decided on the Analyzer immediately after the first run Rerun decided during technical validation on the Analyzer Manager Rerun decided during clinical validation on the Order Filler Reflex Reflex decided on the Analyzer Reflex decided during technical validation on the Analyzer Manager Reflex decided during clinical validation on the Order Filler Retransmit results from Analyzer QC Performed on an Analyzer Pooling of Patient Specimens
6 LAB-27 Query for AWOS Two-part message exchange LAB-27 (query) followed by LAB-28 (AWOS Broadcast) Allows Analyzer to continue while Analyzer Manager processes the query Allows Analyzer to accept/reject AWOS Analyzer Manager Analyzer QBP^Q11^QBP_Q11 (Query for AWOS) RSP^K11^RSP_K11 (Acknowledgement of Query) Specimen recognized
7 LAB-28 AWOS Broadcast New and Cancel AWOS Modify is cancel followed by new Requires Analyzer response to request Analyzer Manager Analyzer OML^O33 New Order (ORC-1: NW) ORL^O34 Order Accepted (ORC-1: OK) Unable to Accept (ORC-1: UA) OML^O33 Order Cancel (ORC-1: CA) ORL^O34 Order Cancelled (ORC-1: CR) Unable to Cancel (ORC-1: UC)
8 LAB-29 AWOS Status Change Test results Test exceptions Analyzer Manager Analyzer OUL^R22 (Test Result) ACK^R22 (Result Accepted)
9 Options Orders (Bi-directional communication) Some Analyzers do not support orders (e.g. instrument with fixed tests) A profile option for Analyzers Query is default mode when orders are supported Basic and enhanced message interfaces All Analyzers must support basic interface to transmit results Basic interface elements are mandatory for Analyzers and Analyzer Managers Basic elements are tested for conformance Some Analyzers support additional information (e.g. patient information) to further evaluate results Analyzer Managers must support enhanced elements Analyzers may support enhanced elements based on capabilities (options) Enhanced elements are not part of conformance testing for Analyzers
10 LAW Special Topics AWOS ID Every AWOS request is assigned a unique ID by the Analyzer Manager No AWOS ID is assigned for AWOS requests created at the Analyzer Sample identification Sample container is used for identification Specimen identification is optional Standard vocabulary support Universal Service Identifier Logical Observation Identifiers Names and Codes (LOINC) JLAC10 Japanese standard clinical test code Units of Measure Unified Code for Units of Measure (UCUM) Device Identification Vendor model and serial number Support for Universal Device Identifier (UDI)
11 LAW Special Topics Orders AWOS Query Related observations Prior observations Clinical information AWOS acceptance AWOS cancellation
12 LAW Special Topics Observations AWOS (order) status Result status Identification of runs Unique identification of results (Microbiology) Result Fragments Quantitative (10.3) Qualitative (Positive, > 100) Supplemental Observations Plots Images Raw values Contributing substances Analyzer initiated reflex
13 Law Special Topics Message handling Identification Acknowledgement Connectivity HL7 MLLP Two TCP/IP Connections Sender Receiver Connection persistence
14 LAW Special Topics Error handling Malformed messages Messages with incorrect content Reject a message Messages with content inconsistent with previous messages Managing patient demographic data
15 Important Links IHE Laboratory Wiki LAW Wiki LAW Supplement for Trial Implementation IICC Website
IHE Laboratory Technical Framework Supplement. Laboratory Analytical Workflow (LAW) Trial Implementation
Integrating the Healthcare Enterprise 5 IHE Laboratory Technical Framework Supplement 10 Laboratory Analytical Workflow (LAW) 15 Trial Implementation 20 Date: 2015-03-16 Author: IHE Laboratory Technical
Pathology Images, DICOM, and LIS/PACS Integration. Harry Solomon, GE Healthcare Co-Chair, DICOM WG-20 / HL7 Imaging Integration WG
Pathology Images, DICOM, and LIS/PACS Integration, GE Healthcare Co-Chair, DICOM WG-20 / HL7 Imaging Integration WG Disclosure Employee, GE Healthcare 2 Pathology Informatics 2012 Topics Brief overview
Adding Management. www.starlims.com
Adding Management to Your LIS Given the dynamic nature of their operations, today s clinical laboratories need to be nimble and agile. They need to cope with ever changing requirements brought about by
ONC s Laboratory Results Interface (LRI) and Laboratory Orders Interface (LOI) Implementation Guides and LIS-EHR Data Exchange
ONC s Laboratory Results Interface (LRI) and Laboratory Orders Interface (LOI) Implementation Guides and LIS-EHR Data Exchange Pathology Informatics 2015 May 6, 2015 Pittsburgh, PA Walter H. Henricks,
IHE Laboratory (LAB) Technical Framework. Volume 1 LAB TF-1 Integration Profiles
Integrating the Healthcare Enterprise 5 10 IHE Laboratory (LAB) Technical Framework Volume 1 LAB TF-1 Integration Profiles 15 20 Revision 6.0 - Final Text July 14, 2015 25 Please verify you have the most
Hematology, Chemistry, Microbiology. Clinical Pathology and Anatomic Pathology. Hospital Information System or Practice Management System
Take your laboratory to market and stay competitive. Harvest the power of laboratory outreach and connectivity to your clients EMRs with Orchard Copia. Today, for laboratory outreach, EMR integration and
Accelerating EMR Interoperability with ELINCS. Streamlining Lab Connectivity to Physician EMRs
Accelerating EMR Interoperability with ELINCS Streamlining Lab Connectivity to Physician EMRs A New Standard for Electronic Results What is ELINCS? The EHR-Lab Interoperability and Connectivity Standards
Test Procedure for 170.314(b)(6) Transmission of electronic laboratory tests and values/results to ambulatory providers inpatient setting only
Approved Test Procedure Version 1.3 January 16, 2013 Test Procedure for 170.314(b)(6) Transmission of electronic laboratory tests and This document describes the test procedure for evaluating conformance
IHE Eye Care Technical Framework Supplement. Unified Eye Care Workflow Refractive Measurements (U-EYECARE Refractive) Draft for Public Comment
Integrating the Healthcare Enterprise 5 IHE Eye Care Technical Framework Supplement 10 Unified Eye Care Workflow Refractive Measurements (U-EYECARE Refractive) 15 Draft for Public Comment 20 Date: April
Do-it-Yourself, Simple Installation. Simple Review, Click, & Go EHR Connectivity. Cost Savings & Benefits. Multiple Trellis Deployment Options
With today s healthcare challenges surrounding efficiency and accountability and the economic pressure to do more with less, TM provides the optimal means for electronic connectivity to more effectively
ELR 2.5.1 Clarification Document for EHR Technology Certification
ELR 2.5.1 Clarification Document for EHR Technology Certification Date: July 16, 2012 Co-Authored By: Centers for Disease Control and Prevention And Association of Public Health Laboratories Table of Contents
Relationship of HL7 EHR System Draft Standard to X12N
Relationship of HL7 EHR System Draft Standard to X12N EHR Technical Committee Co-Chairs: Gary Dickinson Linda Fischetti Sam Heard Excerpt of EHR-S DSTU Class Overview of Discussion Background Where We
Understanding Meaningful Use with a Focus on Testing the HL7 V2 Messaging Standards
Understanding Meaningful Use with a Focus on Testing the HL7 V2 Messaging Standards Robert Snelick, National Institute of Standards and Technology (NIST) Sheryl Taylor, Booz-Allen Hamilton (BAH) Use of
Meaningful Use Stage 2 as it Relates to the Lab Implementing the Public Health Agency Interface. Interface
Meaningful Use Stage 2 as it Relates to the Lab Implementing the Public Health Agency Interface Interface Topics Covered Meaningful Use Stage 2 (MU2) Electronic Lab Results (ELR) interface Lab Results
ELR 2.5.1 Clarification Document for EHR Technology Certification V1.1
ELR 2.5.1 Clarification Document for EHR Technology Certification V1.1 Date: October 16, 2012 Co-Authored By: Centers for Disease Control and Prevention And Association of Public Health Laboratories Table
Registration Hold Capabilities in EMR-Link
Registration Hold Capabilities in EMR-Link Introduction Registration Hold refers to the ability to hold an incoming electronic order in an order queue, until all the required information for the order
Meaningful use. Meaningful data. Meaningful care. The 3M Healthcare Data Dictionary: Standardizing lab data to LOINC for meaningful use
Meaningful use. Meaningful data. Meaningful care. The 3M Healthcare Data Dictionary: Standardizing lab data to LOINC for meaningful use Executive summary By using standard terminologies to report on core
Advancing Laboratory Interoperability in Health IT
Advancing Laboratory Interoperability in Health IT Introduction & CDC LabHIT Update Megan E. Sawchuk, MT(ASCP) Health Scientist Clinical Laboratory Improvement Advisory Committee (CLIAC) 8-22-2013 Center
Trends in Healthcare Information Standardization
TANJI Natsuki Abstract Standardization of medical information systems by industry associations such as ISO/TC 215 and CEN/TC 251 is currently underway internationally. In Japan, too, participation in and
Conformance Testing of Healthcare Data Exchange Standards for EHR Certification
Int'l Conf. Health Informatics and Medical Systems HIMS'15 105 Conformance Testing of Healthcare Data Exchange Standards for EHR Certification R. Snelick 1 1 National Institute of Standards and Technology
LOINC Mapping AND MAINTENANCE SERVICES. CLINICAL DATA NORMALIZATION through LOINC Mapping TURN OVER TO LEARN MORE. Test Dictionary Process
LOINC Mapping AND MAINTENANCE SERVICES CLINICAL DATA NORMALIZATION through LOINC Mapping Halfpenny Technologies offers LOINC code mapping as one of our clinical data services (CDS). With basic test directory
HL7 V2 Implementation Guide Authoring Tool Proposal
HL7 V2 Authoring Tool Proposal Robert Snelick, NIST National Institute of Standards and Technology May 14 th 2012 Contact: [email protected] NIST and Veterans Administration Joint Project NIST will provide
Clinical Document Exchange Integration Guide - Outbound
Clinical Document Exchange Integration Guide - Outbound Integrate your healthcare IT system with Practice Fusion s Electronic Health Record (EHR) System Table of Contents 1 Introduction... 2 2 Integration
Measuring the Interoperability Degree of Interconnected Healthcare Information Systems Using the LISI Model
Measuring the Interoperability Degree of Interconnected Healthcare Information Systems Using the LISI Model Mihaela Vida*, Lăcrămioara Stoicu-Tivadar*, Elena Bernad**, *Faculty of Automatics and Computers,
LIS Interfaces: Basics, Implementation and Pitfalls
A Review of Pathology Informatics LIS Interfaces: Basics, Implementation and Pitfalls James H. Harrison, Jr., M.D., Ph.D. Division of Biomedical Informatics Departments of Public Health Sciences and Pathology
Advanced Matching and IHE Profiles
Oracle Healthcare Master Person Index INTEGRATING THE HEALTHCARE ENTERPRISE Oracle Healthcare Master Person Index provides a single point of reference to information about a patient, clinician, payer,
ImagePilot. HL7 Conformance Statement. Manufacturer: 1 Sakura-machi, Hino-shi Tokyo 191-8511, Japan
ImagePilot HL7 Conformance Statement Manufacturer: 1 Sakura-machi, Hino-shi Tokyo 191-8511, Japan Revision History Date Version Description August 28, 2009 Rev. 1.0 April 1, 2010 Rev. 1.1 Values that
CHAN Health Information Exchange (MPI/HIE) RFP
RESPONSE TO QUESTIONS CHAN Health Information Exchange (MPI/HIE) RFP Question 1 Does CHAN have an interest in Secure Messaging? Yes Answer 2 It appears that you want an on premise solution (hosted) or
CPHIMS-CA CANADIAN SUPPLEMENTAL EXAMINATION CANDIDATE HANDBOOK
CPHIMS-CA CANADIAN SUPPLEMENTAL EXAMINATION CANDIDATE HANDBOOK 2013 About this Candidate Handbook The CPHIMS-CA (Certified Professional in Healthcare Information and Management Systems Canada) credential
Managing POCT: Trying to Control Testing in an Out-of-Control Environment. William Clarke, PhD, MBA, DABCC Johns Hopkins School of Medicine 3/24/11
Managing POCT: Trying to Control Testing in an Out-of-Control Environment William Clarke, PhD, MBA, DABCC Johns Hopkins School of Medicine 3/24/11 Learning Objectives Participants should be able to: Discuss
Direct Secure Messaging: Improving the Secure and Interoperable Exchange of Health Information
Direct Secure Messaging: Improving the Secure and Interoperable Exchange of Health Information Within the healthcare industry, the exchange of protected health information (PHI) is governed by regulations
Bi-Directional Interface between EMR and Quest Diagnostics Microsoft.NET with SQL Server Reporting Services solution for Healthcare Company
Bi-Directional Interface between EMR and Quest Diagnostics Microsoft.NET with SQL Server Reporting Services solution for Healthcare Company Executive Summary One of our EMR clients approached us to setup
Presenter. Deborah Kohn, MPH, RHIA, CHE, CPHIMS Principal Dak Systems Consulting San Mateo, CA
INTEGRATING THE HEALTHCARE ENTERPRISE (IHE): AN INTERNATIONAL APPROACH TO THE DEVELOPMENT OF IMPLEMENTATION GUIDES FOR ELECTRONIC HEALTH RECORD SYSTEMS The 14th Congress of the International Federation
Ross Cantor Director of Sales and Client Relations Lifepoint Informatics
Lifepoint User Conference 2014 Leveraging CPOE Connect for Clean Orders: Embedding Lifepoint s Best of Breed Order Entry Functionality into Disparate EMR Systems Ross Cantor Director of Sales and Client
Public Health Reporting Initiative Functional Requirements Description
Public Health Reporting Initiative Functional Requirements Description 9/25/2012 1 Table of Contents 1.0 Preface and Introduction... 2 2.0 Initiative Overview... 3 2.1 Initiative Challenge Statement...
HL7 Conformance Statement
HL7 Conformance Statement Release VA20B (2014-03-28) ITH icoserve technology for healthcare GmbH Innrain 98, 6020 Innsbruck, Austria +43 512 89059-0 www.ith-icoserve.com Any printout or copy of this document
Business and Technical Description of Commercial Systems The scope of the technical solution is further described below.
Introduction MaxMD is pleased to provide the Pennsylvania ehealth Partnership Authority (Authority) the Business and Technical Requirements report under the Lab Grant pilot project. We have demonstrated
Advanced Solutions for Accountable Care Organizations (ACOs)
Advanced Solutions for Accountable Care Organizations (ACOs) Since our founding more than 21 years ago, Iatric Systems has been dedicated to supporting the quality and delivery of healthcare, while helping
Meaningful Use - HL7 Version 2
Meaningful Use - HL7 Version 2 HL7 Version 2 and Surveillance Reporting HIMSS, 2011 Orlando John Quinn, HL7 CTO February 2011 Contributors to Today s Presentation Anna Orlova, PhD, Executive Director,
Structured Data Capture (SDC) The Use of Structured Data Capture for Clinical Research
Structured Data Capture (SDC) The Use of Structured Data Capture for Clinical Research July 2015 S&I Initiative Coordinator: Ed Hammond HHS/ONC Sponsor: Farrah Darbouze SDC Overview Launched in 2013 in
EHR Meaningful Use Stages 1 and 2. What They Mean To You. Pat Wolfram
EHR Meaningful Use Stages 1 and 2 What They Mean To You Pat Wolfram What We ll Cover Update on Meaningful Use Stages 1 and 2 EMR Trends and Learnings During MU Stage 1 But It s Really More Than Just Meaningful
IBM Interoperable Healthcare Information Infrastructure (IHII) Overview. China October 2006 IBM
Interoperable Healthcare Information Infrastructure (IHII) Overview China October 2006 Rick Stevens Senior Technical Staff Member Healthcare and Life Science Solutions IHE IT Infrastructure Technical Committee
JiveX Enterprise PACS Solutions. JiveX HL7 Gateway Conformance Statement - HL7. Version: 4.7.1 As of 2015-05-20
JiveX Enterprise PACS Solutions JiveX HL7 Gateway Conformance Statement - HL7 Version: 4.7.1 As of 2015-05-20 VISUS Technology Transfer GmbH Universitätsstr. 136 D-44799 Bochum Germany Phone: +49 (0) 234
Middleware for Medical Device Interoperability using Ontology-based Description and Mapping
Middleware for Medical Device Interoperability using Ontology-based Description and Mapping Asiah Mahmood, Farooq Ahmed, Khalid Latif, Hamid Mukhtar and Syed Ali Raza School of EE & CS,National University
IHE Radiology Technical Framework Supplement. Imaging Object Change Management (IOCM) Trial Implementation
Integrating the Healthcare Enterprise 5 10 IHE Radiology Technical Framework Supplement Imaging Object Change Management 15 Trial Implementation 20 Date: May 17, 2011 Author: Kinson Ho, David Heaney Email:
Health Information Exchange. Scalable and Affordable
Integration is Everything Health Information Exchange Scalable and Affordable Today s healthcare organizations are transforming the quality of patient care by electronically exchanging patient data at
Health IT Enabled Quality Measurement and Improvement: The HL7 Clinical Quality Information Workgroup
Health IT Enabled Quality Measurement and Improvement: The HL7 Clinical Quality Information Workgroup Walter G. Suarez, MD, MPH Executive Director, Health IT Strategy and Policy Kaiser Permanente Co-Chair,
Interoperable Medical Record Exchange System among Hospitals in Ethiopia using EMR
Interoperable Medical Record Exchange System among Hospitals in Ethiopia using EMR Tigist Tedla HiLCoE, Computer Science Programme, Ethiopia [email protected] Abrehet Omer HiLCoE, Ethiopia Department
Success of DICOM standard
International Telecommunication Union Success of DICOM standard Cor Loef Industry Co-Chair DICOM Strategic Advisory Committee Workshop on Standardization in E-health Geneva, 23-25 May 2003 Success of DICOM
Connecting Cardiac Device Data and the EHR
Connecting Cardiac Device Data and the EHR Introduction In an age of complex information needs, healthcare providers often use a staggering variety of applications to capture a patient s complete clinical
What is the Certified Health Record Analyst (CHDA)?
What is the Certified Health Record Analyst (CHDA)? Ellen S. Karl, MBA, RHIA, CHDA, FAHIMA Exam specifics; how long is it, how do I apply, etc.? Exam specifics; how long is it, how do I apply, etc.? Number
Electronic Public Health Case Reporting: Current & Future Possibilities. Joint Public Health Forum & CDC Nationwide Call October 16, 2014
Electronic Public Health Case Reporting: Current & Future Possibilities Joint Public Health Forum & CDC Nationwide Call October 16, 2014 1 Joint Public Health Forum & CDC Nationwide Call Agenda Introduction
Instructions for Preparing an RFP/RFI Using This Template
Instructions for Preparing an RFP/RFI Using This Template Note: This Sample RFP/RFI is designed for facilities who are in the market for a Laboratory Information System with basic web outreach only. If
Going Beyond Laboratory Automation: Do Less Accomplish More. Swedish Covenant Hospital
Going Beyond Laboratory Automation: Do Less Accomplish More Susan Dawson, MBA, MT(ASCP) Swedish Covenant Hospital Chicago, IL Swedish Covenant Hospital Open Heart Oncology Birthing Unit Community Outreach
Electronic Health Records - An Overview - Martin C. Were, MD MS March 24, 2010
Electronic Health Records - An Overview - Martin C. Were, MD MS March 24, 2010 Why Electronic Health Records (EHRs) EHRs vs. Paper Components of EHRs Characteristics of a good EHRs A Kenyan EHRs implementation
How To Use Data Analysis To Get More Information From A Computer Or Cell Phone To A Computer
Applying Big Data approaches to Competitive Intelligence challenges THOMSON REUTERS IP & SCIENCE PHARMA CI EUROPE CONFERENCE & EXHIBITION TIM MILLER 19 FEBRUARY 2014 BIG DATA, NOT JUST ABOUT VOLUMES Patient
Integrating the Healthcare Enterprise (IHE)
Technical Publications DOC0347844 Revision 3 Discovery VCT Discovery RX VCT Discovery ST Discovery STE Discovery RX Integrating the Healthcare Enterprise (IHE) Integration Statement Copyright 2009 by General
HL7 and Meaningful Use
HL7 and Meaningful Use Grant M. Wood HL7 Ambassador HIMSS14 2012 Health Level Seven International. All Rights Reserved. HL7 and Health Level Seven are registered trademarks of Health Level Seven International.
IHE Radiology Technical Framework Volume 3 (IHE RAD TF-3)
Integrating the Healthcare Enterprise IHE Radiology Technical Framework Volume 3 (IHE RAD TF-3) Transactions (continued) Revision 10.0 Final Text February 18, 2011 Contents 1 Introduction... 3 1.1 Overview
HL7 Conformance Statement RadCentre. Release 2015.01
HL7 Conformance Statement Release 2015.01 Editing The editing is done by i-slutins Health GmbH. If you have any suggestions for improvement or requests for modification etc, please let us know. You can
Interoperability and Integrating the Healthcare Enterprise
Interoperability and Integrating the Healthcare Enterprise Nicholas Brown Thanks to Dave Plummer and Mark Shafarman for some slides 24th January 2008 1 Overview What is Interoperability? What is IHE? What
Oracle Utilities Integration for Device Operations
Oracle Utilities Integration for Device Operations Release Notes Oracle Utilities Meter Data Management v2.0.1.8 Oracle Utilities Operational Device Management v2.0.1 E36211-01 October 2012 Oracle Utilities
New Jersey Department of Health. Electronic Laboratory Reporting On-Boarding Manual. Version 1.4
New Jersey Department of Health On-Boarding Manual Version 1.4 Table of Contents 1. Introduction 3 1.1 Purpose 3 1.2 Scope 3 1.3 Definitions, Acronyms and Abbreviations 4 1.4 References 5 1.5 Overview
TECHNICAL SPECIFICATIONS GUIDE CANADA SAVINGS BONDS. csb.gc.ca PAYROLL SAVINGS PROGRAM 20$ 40$ 80$ 50 $ 30$ TECHGUIDE-14
7 TECHNICAL SPECIFICATIONS GUIDE CANADA SAVINGS BONDS PAYROLL SAVINGS PROGRAM csb.gc.ca 40 5 30 0 20 80 70 0 What are you saving for? 50 40 20 0 80 4 20 7 7 TECHGUIDE-4 TECHNICAL SPECIFICATIONS GUIDE For
NAACCR 2015 Annual Conference Sandy Jones June 18, 2015
USE OF INTEGRATING THE HEALTHCARE ENTERPRISE (IHE) STANDARDIZED DATA CAPTURE (SDC) CONTENT PROFILE TO EXCHANGE STANDARDIZED DATA BETWEEN CLINICAL CARE AND CANCER REGISTRIES NAACCR 2015 Annual Conference
Integrating the Healthcare Enterprise (IHE) Integration Statement
GE Healthcare Technical Publications Document Number: DOC0677276 Revision: 2 Centricity EMR Version 9.3 Integrating the Healthcare Enterprise (IHE) Integration Statement Copyright 2005 by General Electric
Intelligent laboratory management Delivered by cobas IT middleware
For technical specifications and additional information please see the enclosed datasheets. Intelligent laboratory management Delivered by cobas IT middleware To arrange a meeting or demonstration to learn
HL7 Conformance Statement
HL7 Conformance Statement Product Image-Arena 4.3 Product No.: T.08.0122 Effective Date: 2010-04-30 Benjamin Wagner Document 04 rev.: D32.0083-04 Image-Arena 4.3 HL7 conformance statement Table of contents
Integrating the Healthcare Enterprise (IHE) What it is, where we are, and why it is important
Integrating the Healthcare Enterprise (IHE) What it is, where we are, and why it is important Darcy Del Dotto June 2014 Introduction The healthcare industry has always been a changing and developing field.
Eligible Professionals please see the document: MEDITECH Prepares You for Stage 2 of Meaningful Use: Eligible Professionals.
s Preparing for Meaningful Use in 2014 MEDITECH (Updated December 2013) Professionals please see the document: MEDITECH Prepares You for Stage 2 of Meaningful Use: Professionals. Congratulations to our
Centers for Disease Control and Prevention, Public Health Information Network Messaging System (PHINMS)
1 ebxml Case Study 2 3 4 5 Centers for Disease Control and Prevention, Public Health Information Network Messaging System (PHINMS) 4 October 2003 6 7 8 9 10 11 12 13 14 15 16 17 Document identifier: (Word)
IHE Integrating the Healthcare Enterprise) HIS HL7
IHE Integrating the Healthcare Enterprise) HIS HL7 Prefeching Preloading CRT Net work CRT Dx DP Tool ATM DIN PACS DICOM DoD VRE 90 93 96 00 Example: Scheduled Workflow Profile Registration HIS patient
Meaningful Use - HL7 Version 2
Meaningful Use - HL7 Version 2 HL7 Version 2 and Surveillance Your Ambassadors Today Anna Orlova, PhD, Executive Director, Public Health Data Standards Consortium and Johns Hopkins University Lori Reed-Fourquet,
MOSAIQ External Systems Interfaces (ESI) Product Offerings
MOSAIQ External Systems Interfaces (ESI) Product Offerings (Current as of MOSAIQ 2.60) Elekta offers a broad range of external systems interfaces to connect oncology clinician and administrative personnel
Integrating EHR and EDC systems
Integrating EHR and EDC systems Dr. Wolfgang Summa Integration of EDC and electronic Health Records (ehr & phr) Exec. VP Europe & Asia/Pacific Dr. Wolfgang Summa OmniComm Europe GmbH22nd Annual Executive
IHE Pharmacy Technical Framework Supplement. Pharmacy Medication List (PML) Trial Implementation
Integrating the Healthcare Enterprise 5 IHE Pharmacy Technical Framework Supplement 10 Pharmacy Medication List (PML) 15 Trial Implementation 20 Date: September 29, 2014 Author: IHE Pharmacy Technical
HL7 and Meaningful Use
HL7 and Meaningful Use HIMSS Las Vegas February 23, 2012 Grant M. Wood Intermountain Healthcare Clinical Genetics Institute Meaningful Use What Does It Mean? HITECH rewards the Meaningful Use of health
SHIB PROJECT Coding Standards CCHI Data Dictionary
SHIB SHIB PROJECT Coding Standards CCHI Data Dictionary Context of the CCHI Data Dictionary Coding Standards The purpose is to define the core coding standards which are integral to the health insurance
Prepared by Noam H. Arzt, PhD HLN Consulting, LLC
Architectures and Transport Mechanisms for Health Information Interchange of Clinical EHR Data for Syndromic Surveillance A Report from the International Society for Disease Surveillance Prepared by Noam
The CDISC Laboratory Data Interchange Standard: Using SAS To Read and Write CDISC Compliant Data Sets and Files
The CDISC Laboratory Data Interchange Standard: Using SAS To Read and Write CDISC Compliant Data Sets and Files Margaret Hung, GlaxoSmithKline Philip M. Pochon, Covance Central Laboratory Services, Inc.
A Semantic Foundation for Achieving HIE Interoperability
A Semantic Foundation for Achieving HIE Interoperability Introduction Interoperability of health IT systems within and across organizational boundaries has long been the holy grail of healthcare technologists.
Sutter Health Support Services Shared Laboratory Position Description. Incumbent: Laboratory Date: October 23, 2006 Written By: Michele Leonard
Sutter Health Support Services Shared Laboratory Position Description Position Title: Clinical Laboratory Scientist, Microbiologist Incumbent: Entity: SHSS Shared Laboratory Reports To: Director of Operations,
CDX Conformance Profile - 001 EMR System Conformance CDA Level 1
CDX Conformance Profile - 001 EMR System Conformance CDA Level 1 15-Aug-2014 Version 2.0 Status: Final CDA Level 1 Conformance Profile 001 Page 1 of 36 Document Version Control Release Date Version Status