Compact Product Suite Panel 800 Version 6 PP877 Hardware and Installation
|
|
|
- Barnaby Burke
- 10 years ago
- Views:
Transcription
1 Compact Product Suite Panel 800 Version 6 PP877 Hardware and Installation
2
3 Panel 800 Version 6 - PP877 Hardware and Installation
4 NOTICE This document contains information about one or more ABB products and may include a description of or a reference to one or more standards that may be generally relevant to the ABB products. ABB may have one or more patents or pending patent applications protecting the intellectual property in the ABB product(s) described in this publication. The presence of any such description of a standard or reference to a standard is not a representation that all of the ABB products referenced in this document support all of the features of the described or referenced standard. In order to determine the specific features supported by a particular ABB product, the reader should consult the product specifications for the particular ABB product. The information in this document is subject to change without notice and should not be construed as a commitment by ABB. ABB assumes no responsibility for any errors that may appear in this document. In no event shall ABB be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, nor shall ABB be liable for incidental or consequential damages arising from use of any software or hardware described in this document. This document and parts thereof must not be reproduced or copied without written permission from ABB, and the contents thereof must not be imparted to a third party nor used for any unauthorized purpose. The software or hardware described in this document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license. This product meets the requirements specified in EMC Directive 2004/108/EC and in Low Voltage Directive 2006/95/EC. TRADEMARKS All rights to copyrights, registered trademarks, and trademarks reside with their respective owners. Copyright 2015 ABB. All rights reserved. Release: May 2015 Document number: 3BSE Rev E
5 Contents CONTENTS Section 1 - Introduction General... 7 Warning, Caution, Information, and Tip Icons... 8 Section 2 - Safety Precautions General... 9 UL and cul Installation During Installation During Use Service and Maintenance Dismantling and Scrapping Appearance of Air in Touch Screen Section 3 - Installation Space Requirements Installation Process Connections to the Controller Other Connections and Peripherals Section 4 - Technical Data Section 5 - Chemical Resistance Metal Casing Touch Screen and Overlay Material Autoflex EBA 180L Touch Screen Surface Touch Screen Protection Film BSE Rev E 5
6 Contents Section 6 - Operator Panel Drawings Connectors Communication Ports PP877 Outline Section 7 - Additional Installation Tips Grounding the operator panel Ethernet Connection in the Operator Panel To Achieve Better EMC Protection Ambient Temperature Safety Galvanic Isolation Cable and Bus Termination RS BSE Rev E
7 Section 1 Introduction General AllPanel800Version6aredevelopedtosatisfythedemandsofhuman-machine communication. Built-in functions such as displaying and controlling text, dynamic indication, time channels, alarm and recipe handling are included. The Panel 800 Version 6 works primarily in an object-oriented way, making it easy to understand and use. Configuration is carried out on a PC using the Panel Builder configuration tool. The project can then be transferred and stored in the operator panel itself. Various types of automation equipment such as PLCs, servos or drives can be connected to the Panel 800 Version 6. In this manual, the term the controller refers to the connected equipment. This manual explains how to install the operator panel. Please refer to the Panel Builder Programming and Installation manual for further information. Description Initial release of PP877 UL approval Amended UL battery information Amended UL information regarding power supply Updated UL information User Documentation 3BSE BSE Rev A 3BSE Rev B 3BSE Rev C 3BSE Rev D 3BSE Rev E 7
8 Warning, Caution, Information, and Tip Icons Section 1 Introduction Warning, Caution, Information, and Tip Icons This publication includes Warning, Caution, and Information where appropriate to point out safety related or other important information. It also includes Tip to point out useful hints to the reader. The corresponding symbols should be interpreted as follows: Electrical warning icon indicates the presence of a hazard which could result in electrical shock. Warning icon indicates the presence of a hazard which could result in personal injury. Caution icon indicates important information or warning related to the concept discussed in the text. It might indicate the presence of a hazard which could result in corruption of software or damage to equipment/property. Information icon alerts the reader to pertinent facts and conditions. Tip icon indicates advice on, for example, how to design your project or how to use a certain function. Although Warning hazards are related to personal injury, and Caution hazards are associated with equipment or property damage, it should be understood that operation of damaged equipment could, under certain operational conditions, result in degraded process performance leading to personal injury or death. Therefore, fully comply with all Warning and Caution notices. 8 3BSE Rev E
9 Section 2 Safety Precautions Both the installer and the owner and/or operator of the operator panel must read and understand this installation manual. General Read the safety precautions carefully. Check the delivery for transportation damage. If damage is found, notify the supplier as soon as possible. The supplier is not responsible for modified, altered or reconstructed equipment. Use only parts and accessories manufactured according to specifications of the supplier. Read the installation and operating instructions carefully before installing, using or repairing the operator panel. Never allow fluids, metal filings or wiring debris to enter any openings in the operator panel. This may cause fire or electrical shock. Only qualified personnel may operate the operator panel. Storing the operator panel where the temperature is lower/higher than recommended in this manual can cause the LCD display liquid to congeal/become isotopic. The LCD display liquid contains a powerful irritant. In case of skin contact, wash immediately with plenty of water. In case of eye contact, hold the eye open, flush with plenty of water and get medical attention. The figures in this manual serves an illustrative purpose. Because of the many variables associated with any particular installation, the supplier cannot assume responsibility for actual use based on the figures. 3BSE Rev E 9
10 UL and cul Installation Section 2 Safety Precautions The supplier neither guarantees that the operator panel is suitable for your particular application, nor assumes responsibility for your product design, installation or operation. It is recommended to turn on and shut down the operator panel at least once before installing any components/cards or before connecting the operator panel to external devices, like for example serial devices. UL and cul Installation This section is only valid for UL labeled PP877 panels. This equipment is suitable for use in Class 2 non-hazardous locations only. [Combinations of equipment in your system are subject to investigation by the local authority having jurisdiction at the time of installation]. All devices have to be supplied by a Class 2 power supply. Do not disconnect equipment unless power has been removed or the area is known to be non-hazardous AVANT DE DECONNECTER L EQUIPEMENT, COUPER LE COURANT OUS ASSURER QUE L EMPLACEMENT EST DESIGNE NON DANGEREUX. Only UL and cul approved expansion units are allowed to be connected to the port designated EXPANSION. At the moment there are no such units evaluated or allowed. SEULES LES UNITÉS D'EXTENSION CERTIFIÉES UL ET cul PEUVENT ÊTRE RACCORDÉES AU PORT DÉSIGNÉ «EXPANSION». ÀL'HEURE ACTUELLE, AUCUNE UNITÉ DE CE TYPE N'A ÉTÉ TESTÉE OU AUTORISÉE. Do not replace expansion unit unless power has been switched off or the area is known to be non-hazardous. NE REMPLACEZ L'UNITÉ D'EXTENSION QUE SI LE COURANT A ÉTÉ COUPÉ OU SI LA ZONE EST JUGÉE NON DANGEREUSE. This product contains a battery; this must only be changed in an area known to be non-hazardous. 10 3BSE Rev E
11 Section 2 Safety Precautions UL and cul Installation Replace the battery with a BR 2032 battery. Use of another type of battery maypresentariskoffire or explosion. Battery may explode if mistreated. Do not recharge, disassemble or dispose of in fire. LA BATTERIE PEUT EXPLOSER EN CAS DE MAUVAISE MANIPULATION. NE LA RECHARGEZ PAS, NE LA DÉMONTEZ PAS ET NE LA JETEZ PAS DANS LE FEU. For use on a flat surface of a type 4X enclosure indoor use only. Use minimum 75 C copper conductors only. Tomakewiring connections to the power supply connector, follow the table with cable and torque specifications below: Terminal Block Connector Wire Size TQ Lb.In. X1/X100 Phoenix connectors AWG X1/X100 Anytek connectors AWG These devices are Class 2 supplied programmable controllers (industrial PCs) for the use in industrial control equipment and are intended to be (front) panel mounted (Type 1 and 4x for indoor use only). The enclosure provides a degree of protection of at least IP20, but when installed in an apparatus, it should meet IP54. LE BOÎTIER OFFRE UN DEGRÉ DE PROTECTION D'AU MOINS IP20, MAIS LORSQU'IL EST INSTALLÉ DANS UN APPAREIL, IL DOIT ÊTRE DE CLASSE IP54. 3BSE Rev E 11
12 Service and Maintenance Section 2 Safety Precautions During Installation During Use The operator panel is designed for stationary installation on a planar surface, where the following conditions are fulfilled: no high explosive risks no strong magnetic fields no direct sunlight no large, sudden temperature changes Install the operator panel according to the accompanying installation instructions. Ground the operator panel according to the accompanying installation instructions. Only qualified personnel may install the operator panel. Separate the high voltage, signal and supply cables. Make sure that the voltage and polarity of the power source is correct before connecting the operator panel to the power outlet. Peripheral equipment must be appropriate for the application and location. Keep the operator panel clean. Emergency stop and other safety functions may not be controlled from the operator panel. Do not use excessive force or sharp objects when operating the touch screen. Service and Maintenance Only qualified personnel should carry out repairs. The agreed warranty applies. Before carrying out any cleaning or maintenance operations, disconnect the equipment from the electrical supply. 12 3BSE Rev E
13 Section 2 Safety Precautions Appearance of Air in Touch Screen Clean the display and surrounding front cover with a soft cloth and mild detergent. Replacing the battery incorrectly may result in explosion. Only use batteries recommendedbythesupplier. During the warranty period, the battery needs to be replaced by an authorized ABB service center. Dismantling and Scrapping The operator panel or parts thereof shall be recycled according to local regulations. The following components contain substances that might be hazardous to health and the environment: lithium battery, electrolytic capacitor and display. Appearance of Air in Touch Screen The layer structure of the touch screen contains air and in rare cases appearance of bubbles can arise. This is purely cosmetic and does not affect any functionality of the operator panel. The appearance can occur under certain environmental conditions such as temperature, humidity, and atmospheric pressure. 3BSE Rev E 13
14 Appearance of Air in Touch Screen Section 2 Safety Precautions 14 3BSE Rev E
15 Section 3 Installation Space Requirements Maximum installation plate thickness: 8 mm Space requirements in millimeters when installing the operator panel: 100 [mm] The dimensions on the drawing are not proportional. 3BSE Rev E 15
16 Installation Process Section 3 Installation Installation Process The following is needed: A Phillips/slot screwdriver 1. Unpack and check the delivery. If damage is found, notify the supplier. Place the operator panel on a stable surface during installation. Dropping the operator panel or letting it fall may cause damage. 2. To cut a correct opening for the operator panel, use the cut out dimensions in the outline drawing. For more information, see sections Operator Panel Drawings and Technical Data. 3. Secure the operator panel in position using all the fastening holes and the provided brackets and screws: x Nm 16 3BSE Rev E
17 Power Section 3 Installation Installation Process 4. Connect the cables in the specified order, according to the drawing and steps below. The operator panel must be brought to ambient temperature before it is started up. If condensation forms, ensure that the operator panel is dry before connecting it to the power outlet. Ensure that the operator panel and the controller system have the same electrical grounding (reference voltage level), otherwise errors in communication may occur. Ensure that the voltage and polarity of the power source is correct. Separate high voltage cables from signal and supply cables. Shielded communication cables are recommended. B Controller RS232/ RS422/ RS485 24V DC 24V DC C D A Ethernet Connect cable A. Connect cable B, using an M5 screw and a grounding conductor (as short as possible), that is sized correctly according to local electrical codes. Connect cable C. Connect cable D. The recommended cross-section of the cable is 1.5 mm Carefully remove the protective film over the operator panel display, take care to avoid static electricity that could damage the panel. 3BSE Rev E 17
18 Installation Process Section 3 Installation Only for PP877 panels with part number 3BSE069272R1: When connecting the operator panel to the power outlet for the first time, make sure not to interrupt power for a minimum of 48 hours in order to charge the battery completely. After that, the battery may be charged partly during a shorter period of time. Connections to the Controller For information about the cables to be used when connecting the operator panel to the controller, please refer to the help file for the driver in question. Other Connections and Peripherals Cables, peripheral equipment and accessories must be suitable for the application and its environment. For further details or recommendations, please refer to the supplier. 18 3BSE Rev E
19 Section 4 Technical Data Parameter Front panel, W H D Cut out dimensions, W H Mounting depth Standalone mounting Front panel seal IP 65 Rear panel seal IP 20 Touch screen material Touch screen operations Reverse side material Frame material Weight Serial port for COM1 RS232 and COM2 RS422/RS485 Serial port for COM3 RS232 and COM4 RS422/RS485 Ethernet mm mm PP mm (144 mm including clearance) VESA Note: Maximum screw length for VESA mounting is 4 mm. Usage of longer screws may lead to damage. Polyester on glass, resistive. Overlay: Autoflex EBA 180L (1). 1 million finger touch operations Powder-coated aluminum Powder-coated aluminum 1.5 kg 9-pin D-sub contact with RS232 RTS/CTS, chassis-mounted female with standard locking screws 4-40 UNC 9-pin D-sub contact with RS232 RTS/CTS, chassis-mounted female with standard locking screws 4-40 UNC 1 10/100 Base-T (shielded RJ45) 3BSE Rev E 19
20 Section 4 Technical Data USB Parameter Processor External storage media Flash memory (application memory) Memory RAM LED Real time clock Battery (2) Power consumption at rated voltage Fuse Power supply Display PP877 1 USB Host 2.0, max output current 200 ma 400 MHz ARM9 1 SD card (optional). Only compatible with the standard SD format with up to 2 GB storage capacity. 128 MB SSD (NAND Flash) 128 MB (DDR2) 1 blue/red software programmable Yes (on chip) Lithium battery type BR 2032, soldered or rechargeable battery (2) (Seiko Instruments Part No. MS920-SE or similar), soldered 9.6 W Screen brightness 450 cd/m 2 Internal DC fuse, 2.0 AT, 5 20 mm +24 V DC (18 to 32 V DC) CE: The power supply must conform with the requirements according to IEC and IEC UL and cul: The power supply must conform with the requirements for class II power supplies. TFT-LCD with LED backlight pixels, 64 k colors Screen viewing angle Horizontal: 160, Vertical: 140 Backlight lifetime Active area of display, W H Operating temperature 50,000 hours mm -10 Cto+60 C Storage temperature -20 C to +70 C Relative humidity in operation <85% non-condensed 20 3BSE Rev E
21 Section 4 Technical Data Parameter CE approvals DNV approval UL approval PP877 The equipment conforms completely with the following stated standards or technical specifications: EMCDirective2004/108/EC EMC Directive 2004/108/EC + A1:2011 Low Voltage Directive 2006/95/EC Emission: EN :2007 Immunity: EN :2005 Yes Yes, for UL labeled PP877 panels. (1) See section Chemical Resistance for more information. (2) PP877 panels with part number 3BSE069272R1 use a rechargeable battery. All other versions use a BR 2032 battery. 3BSE Rev E 21
22 Section 4 Technical Data 22 3BSE Rev E
23 Section 5 Chemical Resistance Metal Casing The frame and casing material is powder-coated aluminum. This powder paint withstands exposure to the following chemicals without visible change: Acetic acid 10% Phosphoric acid 4% Citric acid 10% Phosphoric acid 10% Diesel Sea water Distilled water Sodium chloride 2% Edible oil Sodium chloride 20% Fuel oil Sulphuric acid 20% Hydrogen peroxide 3% Tap water The powder paint shows limited resistance to the following chemicals at room temperature: Butanol Nitric acid 3% Hydrochloric acid 5% Nitric acid 10% Isopropyl alcohol Phosphoric acid 43% Sodium hypochlorite 10% Turpentine If exposure to any of the above chemicals is demanded, it is recommended to first test the chemical in a hidden spot of the metal casing. 3BSE Rev E 23
24 Metal Casing Section 5 Chemical Resistance The powder paint shows little or no resistance to the following chemicals at room temperature: Acetic acid, conc. Methyl-ethyl ketone Toluene Acetone Nitric acid 30% Trichlorethylene Ammonia 5% Phenol Xylene Ammonia, conc. Sodium hydroxide 5% 97 octane unleaded petrol Ethyl acetate Sodium hydroxide 30% 98 octane leaded petrol 24 3BSE Rev E
25 Section 5 Chemical Resistance Touch Screen and Overlay Material Touch Screen and Overlay Material Autoflex EBA 180L Autoflex EBA 180L covers the overlay surrounding the screen. Solvent Resistance Autoflex EBA 180L withstands exposure of more than 24 hours duration under DIN Part 2 to the following chemicals without visible change: Ajax / Vim in solution Downy / Lenor (1) Phosphoric acid (<30%) Alkalicarbonate Ethanol Potassium ferricyanide solution (1) Ammonia (<40%) (1) Glycerine Potassium hydroxide (<30%) Acetic acid (<50%) Glycol Pure Turpentine Ariel powder in Gumption (1) SBP 60/95 (1) solution (1) Bleach (1) Hydrochloric acid (<36%) Sulfuric acid (<10%) Castor oil Linseed oil Tomato ketchup Caustic soda (<40%) (1) Methanol Trichloroacetic acid (<50%) Cutting oil Nitric acid (<10%) White Spirit Cyclohexanol Paraffin oil Windex (1) Diacetone alcohol Persil powder in solution (1) Wisk Diesel Petroleum spirit (1) Acetonitrile (1) Extremely faint glossing of the texture was noted. Autoflex EBA 180L withstands DIN Part 2 exposure of up to 1 hour duration to glacial acetic acid without visible change. 3BSE Rev E 25
26 Touch Screen and Overlay Material Section 5 Chemical Resistance Autoflex EBA 180L is not resistant to high pressure steam at over 100 C or the following chemicals: Concentrated mineral acids Concentrated caustic solution Benzyl alcohol Methylene chloride Touch Screen Surface The touch screen surface on the operator panel withstands exposure to the following solvents without visible change: Solvents Acetone Isopropanol Toluene Time 10 minutes 10 minutes 5 hours Touch Screen Protection Film Autoflex EBA 180L It is recommended to use the Autoflex EBA 180L protection film, RX877, that can be ordered from ABB. Solvent Resistance The chemical resistance for Autoflex EBA 180L is described in section Autoflex EBA 180L. Outdoor Use In common with all polyester based films, Autoflex EBA 180L is not suitable for use in conditions of long-term exposure to direct sunlight. The layer structure of the touch screen contains air and in rare cases appearance of bubbles can arise. This is purely cosmetic and does not affect any functionality of the panel. The appearance can occur under certain environmental conditions such as temperature, humidity, and atmospheric pressure. 26 3BSE Rev E
27 Section 6 Operator Panel Drawings Connectors COM 1/2 LAN COM 3/ Pos. Connector Description 1 Power supply +24 V DC (18-32 V DC) 2 COM 1/2 Communication Ports 3 LAN 1 10/100 Base-T (shielded RJ45) 4 COM 3/4 Communication Ports 3BSE Rev E 27
28 Communication Ports Section 6 Operator Panel Drawings Communication Ports Pin Serial port, 9-pin female Serial port, 9-pin female COM1 COM2 COM3 COM4 1 - RS422 Tx+ RS422 Tx+ - RS485 Tx+/Rx+ RS485 Tx+/Rx+ 2 RS232 RxD - RS232 RxD - 3 RS232 TxD - RS232 TxD RS422 Rx+ - RS422 Rx+ 5 GND GND GND GND 6 - RS422 Tx- RS422 Tx- - RS485 Tx-/Rx- RS485 Tx-/Rx- 7 RS232 RTS - - RS422 RTS+ 8 RS232 CTS - - RS422 RTS- 9 - RS422 Rx- - RS422 Rx- In order to utilize two communication ports on the same physical port, the Y-split cable TK860V001 (part number 3BSE069476R1) must be used. Only PP877 panels with part number 3BSE069272R1 are equipped with terminated COM-ports. 28 3BSE Rev E
29 Section 6 Operator Panel Drawings PP877 Outline PP877 Outline Ethernet 24 V DC COM3 RS232 / COM1 RS232 / COM4 RS422/RS485 COM2 RS422/RS max. 8 mm 44 SD memory card slot 228 USB host Expansion port 3BSE Rev E 29
30 PP877 Outline Section 6 Operator Panel Drawings 30 3BSE Rev E
31 Section 7 Additional Installation Tips When experiencing communication problems in for example noisy environments or when operating close to temperature limits, the following recommendations are to be noticed. Grounding the operator panel Door Mounting plate in the cabinet Operator panel Power supply Ferrite core 5 24 V DC The mounting clamps of the operator panel do not provide a secure grounding connection between the panel and the device cabinet, see 1 in drawing above. 1. Connect a wire, that is sized correctly according to local electrical codes, between the quick-connect terminal connector on the operator panel and the chassis of the panel, see 2 in drawing above. 3BSE Rev E 31
32 Grounding the operator panel Section 7 Additional Installation Tips 2. Connect a wire or grounding braid, that is sized correctly according to local electrical codes, between the chassis of the operator panel and the closest grounding point on the door, see 3 in drawing above. 3. Connect a strong but short grounding braid between the door and the device cabinet, see 4 in drawing above. 4. Twist the cables onto the 24 V DC feed, see 5 in drawing above. 2 turns around the ferrite core provide 4 times the suppression of 1 turn. 3 turns around the ferrite core provide 9 times the suppression of 1 turn. A ferrite core suppresses disturbances to the 24 V feed, see 6 in drawing above. The grounding wires should be short and the conductor should have a large area. A long, thin grounding wire has a very high impedance (resistance) at high frequencies and does not guide disturbances to the ground. Multi-wire conductors are better than single wire conductors with the same area. Abraided conductor wire with the same area is even better. The best is a short, thick grounding braid. 32 3BSE Rev E
33 Section 7 Additional Installation Tips Ethernet Connection in the Operator Panel Ethernet Connection in the Operator Panel Industrial Ethernet RJ45 RJ45 RJ45 1 RJ45 Operator panel RJ Operator panel RJ45 Shielded Short and unshielded Operator panel RJ μf 250 V 5 Operator panel RJ45 In some industrial units for Ethernet, the RJ45 contact s shield is connected to the chassis via a capacitor, see 1 in drawing above. The operator panel s Ethernet shield is directly connected to the chassis, see 2 in drawing above. 1. Check whether the other Ethernet unit has its shield directly grounded or grounded via a capacitor. In many cases, connecting the shielded Ethernet cabling to the chassis at both ends is inappropriate. Hum or grounding loops can occur. Unshielded cabling mayevenresultinfewercommunicationerrors. A good solution may be to use a shielded Ethernet cable, but to connect the shield at one end only. One option is to break the shield, see 3 in drawing above. 3BSE Rev E 33
34 Ethernet Connection in the Operator Panel Section 7 Additional Installation Tips A more elegant method is to expand the shielded Ethernet cabling with a piece of unshielded Ethernet cable, see 4 in drawing above. The shield can be grounded via an external 0.1 µf/250 V plastic capacitor, see 5 in drawing above. This connects the HF transients to ground. 34 3BSE Rev E
35 Section 7 Additional Installation Tips To Achieve Better EMC Protection To Achieve Better EMC Protection Use shielded cables for RS232 communication. Use twisted pair and shielded cabling for RS422 and RS485. Use the cabling intended for the bus type; Ethernet, Profibus, CC-Link, CAN, Device Net etc. Install and connect according to applicable specifications for the relevant bus standard. Use shielded cabling for Ethernet, preferably with foil and a braided shield. D-sub covers should be shielded, and the shield should be connected to the cover 360 where the cable enters. Connect the shield at both ends. Shielded cable 0.1 μf/250 V Ground plane 1 Ground plane 2 Not same potential Ground plate Ground plate in another building With longer distances, there is a risk that the ground potential may be different. In that case, the shield should only be connected at one end. A good alternative is to connect the other end of the shield to the ground via a 0.1 µf/250 V plastic capacitor. Both ends are then connected to the ground in terms of HF, but only connected to the ground at one end in terms of LF, thus avoiding the 50/60 Hz grounding loops. Metal cabinet Terminal or connector Metal cabinet Terminal or connector Short distance Cable clamp in steel EMC cable gland Plastic cable gland Shielded cable Shielded cable 3BSE Rev E 35
36 Ambient Temperature Section 7 Additional Installation Tips 1. UseanEMCcableglandor regular plastic cable gland, remove the outer jacket and connect the shield to the installation plate with a 360 metal cable clamp. 2. Place the 24 V DC and communications cabling in one cable trunk/cable duct and 230/380 V AC in another. If the cables need to be crossed, cross them at 90 only. Avoid combining the cabling for stronger 24 V DC outputs with the communication cabling. Ferrite cores that are snapped onto the shielded cabling may remove minor disturbances. Large ferrite pieces that are snapped onto unshielded cabling and where the wires go 2-4 times around the cores are approximately 5-25 times more efficient. Ambient Temperature The maximum ambient temperature for the operator panel is provided in the specifications. The ambient temperature refers to the temperature in the device cabinet which cools the operator panel s electronics. Operator panel Top 50 C inside Power 30 C outside Middle 45 C inside Power Power Axial fan 120 x 120 mm Airflow Bottom 40 C inside In most cases, the ambient temperature for the operator panel is significantly higher than the device cabinet s ambient temperature. If the cabinet is tall and there are a number of heat-generating devices, the temperature at the top of the cabinet is considerably higher than the temperature increase that would be expected. All electronics are sensitive to heat. The lifespan of 36 3BSE Rev E
37 Section 7 Additional Installation Tips Ambient Temperature an electrolytic capacitor is cut in half with an 8-10 C increase in temperature. A C temperature increase results in a quarter of the lifespan etc. Rittal has a good program for estimating the anticipated average temperature in the cabinetaswellasalarge program for controlling the temperature in the device cabinet. An enamel-coated steel cabinet has a radiant heat value of 5.5 W/m 2 and degrees C. Installing a fan inside the cabinet evens out the temperature, while moving air provides considerably better cooling than still air. Install the fan so that it sits in a cooler area and blows cold air against the operator panel. If the fan is mounted at the top and sucks warm air upwards, the ambient temperature of the fan becomes higher, resulting in a shorter lifespan. An approximate value of the net power consumption for the operator panel can be calculated by multiplying the supply voltage with the current drawn by the operator panel. This is assuming that all supplied power is transformed to heat. 3BSE Rev E 37
38 Safety Section 7 Additional Installation Tips Safety Most of the operator panels are fed with 24 V DC. 1 Power supply 230 V AC to 24 V DC +24 V 0 V Operator panel 4 2 Power supply 230 V AC to 24 V DC +24 V 0 V Operator panel 4 Distance? 3 Power supply 230 V AC to 24 V DC +24 V 0 V Operator panel 4 COM1 Small controller with expansion unit Ch0 Ch1 230 V AC COM100 Ch100 Ch If a power supply that meets safety standards is used and only feeds the operator panel, there is no problem. See 1 in drawing above. However, if a 24 V unit that also feeds other units is used, there is reason to be cautious, see 2 in drawing above. The operator panel does not have insulation that meets safety requirements in the event of a potential short circuit between 230 V AC and 24 V DC. It is assumed that the 24 V feed is secure, for example, SELV according to EN (protection against electric shock) and UL 950. Here is an example that explains why a secure 24 V DC feed can be ruined by mixing 24 V relay contacts with 230 V AC relay contacts in a smaller controller. Check that the clearances and creepage distances between 24 V DC and 230 V AC fulfill EN or UL 950. If not, input a separate 24 V unit into the operator panel. 38 3BSE Rev E
39 Section 7 Additional Installation Tips Galvanic Isolation Galvanic Isolation If there is a substantial distance between the relay contacts for 24 V DC and 230 V AC, it is OK to use the same 24 V devices for all feeds. See 3 in drawing above. Connect 0 V on the 24 V feed to the ground, see 4 in drawing above. This offers three advantages: Safety is increased. The 24 V feed is not live in the event of a faulty connection or short circuit between 0 V (24 V) and 230 V phase. Transients on the 24 V feed are connected to the ground. Noriskthatthe 24 V feed is at a high level in relationship to the ground. This is not unusual since there is high static electricity. +24 V DC 0 V Filter DC/DC galvanic isolation Internal electronics VCC 0 V (GND) DC/AC Ethernet CFL 1.5 m RS422/485 RS232 USB USB The operator panel has galvanic isolation against the 24 V DC feed but no galvanic isolation between the communication ports for RS232, RS422/485 and USB. Only the Ethernet connection has galvanic isolation. PC Operator panel Modular controller Printer RS422 RS232 USB * * Power CPU COM COM2 * * * * * PC * Different ground potential * * = Internal 0 V (GND) connection 3BSE Rev E 39
40 Cable and Bus Termination RS485 Section 7 Additional Installation Tips When a PC is connected to the operator panel, the internal 0 V (GND) of the panel is connected to the protective ground via the PC. A number of USB devices can have the shield connected together with the protective ground. Here, the 0 V (GND) of the operator panel is connected to the protective ground when, for example, a USB memory stick, keyboard, or similar device is plugged in. If a number of units are connected that have a 0 V and a ground connection, and these are connected to various grounding points, there is a substantial risk of problems. Grounding currents go through communication cables, the rear plate of the controller, and internally in the operator panel, and can cause errors. Use external units to improve communication and achieve galvanic isolation. Westermo has good industry-standard insulators that are also insulated from the 24 V DC feed. It is very important to make sure that the 24 V feed in the external insulation unit is not connected to one of the communication outlets. If it does not have 100% insulation against the 24 V feed, disturbances and grounding currents from the 0 V on the 24 V side disrupts the communication. Using this type of unit solves one problem but creates a larger problem! A substandard installation may work now, but problems may arise when other devices are connected. Cable and Bus Termination RS485 If maximum transfer distance and maximum transfer speed is needed, shielded and twisted pair cable should be used. The mutual capacitance may not exceed 52.5 pf/m, and the cable area should be at least 0.25 mm 2 (AWG 24). 0 V, the reference voltage for communication should be included in the cabling. With two-way communication use two pairs; one pair for communication and one pair for 0 V. The shield must be grounded at one end. The other end is usually grounded, but with longer distances or when there is a difference in the ground potential, the shield should be connected to the ground via 0.1 µf/250 V plastic capacitor to prevent ground current in the braided shield. A number of manufacturers recommend that the shield be grounded at each node. Various manufacturers have different systems for bus termination. 40 3BSE Rev E
41 Section 7 Additional Installation Tips Cable and Bus Termination RS485 Depending on the recipients design, the bus wires may be on the same level or require pull-up or pull-down to ensure that no faulty signals are detected when the bus is in resting mode (all transmitters are disconnected). 3BSE Rev E 41
42 Contact us 3BSE Rev E Copyright 2015 ABB. All rights reserved.
Industrial IT. Panel 800 - PP865 Version 5.1. Hardware and Installation
Industrial IT Panel 800 - PP865 Version 5.1 Hardware and Installation Panel 800 - PP865 Version 5.1 Hardware and Installation NOTICE This document contains information about one or more ABB products and
MITSUBISHI ELECTRIC E1032. Installation manual. English MA00816 2006-04
MITSUBISHI ELECTRIC MA00816 2006-04 E1032 Installation manual English Foreword Installation manual for the E1000 series operator terminals Foreword The E1000 operator terminal is developed to satisfy the
AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134
AC 800M EtherNet/IP DeviceNet Linking Device LD 800DN SP1134 Power and productivity for a better world TM AC 800M EtherNet/IP DeviceNet Linking Device LD 800DN NOTICE This document contains information
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
2100 POS System. 2100 User Guide
2100 POS System 2100 User Guide Thank you for selecting UTC RETAIL s innovative Model 2100 Point of Sale solution! This guide is designed to acquaint you with the features and functionality of the 2100
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)
MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)
MAC Ope ra tor Terminal
MITSUBISHI ELECTRIC MAC Ope ra tor Terminal Human-Machine-Interface In stal la tion Manual MAC 40+ MITSUBISHI ELECTRIC EUROPE B.V. FACTORY AUTOMATION Contents Safety precautions...2 Introduction...4 Function
HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB
Product datasheet Characteristics HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB Main Range of product Product or component type Display colour Display size Supply Magelis
Waveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS
alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS Safety precautions Safety precautions The DSL modem alpha DSL WTM HS complies with the European norm EN60950 safety of information technology
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
Liquid Leakage Sensor Amplifier
9 Liquid Leakage Sensor Amplifier Space-saving Sensor Amplifier reliably detects a wide variety of liquids ranging from water to chemical liquids with low conductivity 1 Detects leakage of liquid such
MultiVOIP FX SIP Gateways
MultiVOIP FX SIP Gateways MVPFX2-2 MVPFX2-4 MVPFX2-8 Cabling Guide Cabling Guide MultiVOIP FX SIP Gateways, Models MVPFX2-2, MVPFX2-4, MVPFX2-8 82100090L Rev. A Copyright This publication may not be reproduced,
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Online UPS. PowerWalker VFI 1000R/1U
Online UPS PowerWalker VFI 1000R/1U Manual Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4.
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug. 2011. RIGOL Technologies, Inc.
Quick Guide DS1000CA Series Oscilloscope Aug. 2011 Technologies, Inc. Guaranty and Declaration Copyright 2011 Technologies, Inc. All Rights Reserved. Trademark Information is a registered trademark of
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
NEWTECH PRO 1-2-3 KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL
NEWTECH PRO 1-2-3 KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL [email protected] / www.tuncmatik.com Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3.
USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920
USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920 [This page intentionally left blank] Warning for Your Protection 1. Read these instructions. 2. Keep these
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface
Options for ABB drives, converters and inverters User s manual FDPI-02 diagnostics and panel interface Table of contents Table of contents 3 1. FDPI-02 diagnostics and panel interface Safety..............................................
C13 User Manual Document ID: 2CMC486004M0201 Revision: A 2013-06-19
C13 C13 Document ID: 2CMC486004M0201 2013-06-19 Disclaimer Copyrights Trademarks Contact The information in this document is subject to change without notice and should not be construed as a commitment
HMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
CELO5. User & Installation Manual. www.audac.eu
CELO5 User & Installation Manual www.audac.eu 2 Introduction 5 High-end Slim Ceiling Speaker The CELO5 is the 5 version of AUDAC s CELO High-end Slim ceiling speaker series with an RMS power of 50 Watt
FN2001-A1 Network module (SAFEDLINK) Mounting Installation
FN00-A Network module (SAFEDLINK) Mounting Installation A6V050_f_en_-- 05-0-6 Building Technologies Division Legal notice Legal notice Technical specifications and availability subject to change without
DLP-PU/E Instruction Manual
Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
aseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
Ingenico. User Guide 5100M. Secure transaction and payment solutions
User Guide Ingenico 5100M Secure transaction and payment solutions Ingenico 5100 M Contents 1 Presentation... 5 1.1 Overview of Ingenico 5100... 6 1.2 Keyboard details and functionality... 7 2 Use...
Senses SV series industrial monitor user manual
Industrial Monitors Senses SV series Senses SV19 / SV17 User manual (Issue A) Part No: 85090084 Page 1 of 25 Copyright Copyright 2008 Amplicon Liveline Ltd. All rights reserved. This publication, including
Backup Scanner Module
Backup Scanner Module Catalog Number 1747-BSN Installation Instructions 2 Backup Scanner Module Important User Information Because of the variety of uses for the products described in this publication,
BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES
NOTES BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability Quick Start Guide This is a Class A device and is not intended for use in a residential environment. Important
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG
alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG Safety precautions Safety precautions The DSL modem alpha DSL WTM EG complies with the European norm EN60950 safety of information technology
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
User Manual 1K/2K/3K Online UPS
User Manual 1K/2K/3K Online UPS Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4. Operation...
MultiVOIP FX FXS-Only SIP Gateways
MultiVOIP FX FXS-Only SIP Gateways MVPFXS-8 MVPFXS-16 MVPFXS-24 Cabling Guide MultiVOIP MVPFXS-8/16/24 Cabling Guide Cabling Guide MultiVOIP FX SIP FXS-Only Gateways Models MVPFXS-8, MVPFXS-16, MVPFXS-24
AXIS T81B22 DC 30W Midspan
INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial
AXIS 291 1U Video Server Rack Installation Guide
AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions
Heat-Tracing Remote Monitoring Module for the NGC Control System Installation Instructions Tools Required 3 mm slotted screwdriver 3/8 hex key (for -4X only) Approvals Nonhazardous locations Type NM LISTED
Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series
Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,
CompactRIO crio-9052
OPERATING INSTRUCTIONS CompactRIO crio-9052 CompactRIO StarFabric Interface 1 POWER BACKUP STATUS FPGA V1 C V2 2 C Rx INPUT 9 35 V 17 W MAX 3 Tx NI crio-9052 CompactRIO StarFabric Interface 1 LEDs 2 Power
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014
EZmoto V2 Product description Rev. 6 10/01/2014 1 Contents 1. Overview... 3 2. Hardware Interface Description... 3 2.1 Main features of the EZmoto... 3 2.2 Hardware block diagram... 4 2.3 Internal Hardware
ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
LIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011
Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.
How To Use A Cdm250 Digital Multimeter
User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s
TECHNICAL SPECIFICATIONS zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s 2015 LitePoint, A Teradyne Company. All rights reserved. The LitePoint zseries 18-slot chassis is an
Instructions A622 100 Amp AC/DC Current Probe 070-8883-03
Instructions A622 100 Amp AC/DC Current Probe 070-8883-03 Revision A www.tektronix.com 070888303 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,
Gateway Port Replicator User Guide
Gateway Port Replicator User Guide Using the Port Replicator Identifying features Connecting and disconnecting the port replicator 1 Using the Port Replicator Top Power button Component Icon Description
Industrial Bar Code Scanners
DS6400 Industrial Bar Code Scanners Configuration SW Tool ACR4 technology PackTrack APPLICATIONS Automated warehousing Medium conveyor sorting Reading on forklift trucks Picking systems Automated shop
Field Information Manager Product guide. Field Information Manager version 1.1
Field Information Manager Product guide Field Information Manager version 1.1 Field Information Manager Product guide Field Information Manager version 1.1 NOTICE TRADEMARKS This document contains information
M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide
M7250P PoE Powered Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX Installation Guide September 2009 VERSITRON, Inc. 83 Albe Drive - Suite C Newark, DE 19702 www.versitron.com www.versitron.com
User manual Compact Web PLC WP240 series IEC-line
User manual Compact Web PLC WP240 series IEC-line update: 09-01-2014 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys
Adjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
2013 Wireless Video Intercom INSTALLATION GUIDE
2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door
SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide
Introduction This guide is to assist the reader with the most basic form of installation and connection to switches in this series. As there is more than one switch in this series, the diagrams might slightly
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch
LwLVision-USB 2.0. Installation Guide
LwLVision-USB 2.0 Installation Guide About this manual This manual has been carefully compiled and examined to the state-of-the-art. G&D neither explicitly nor implicitly takes guarantee or responsibility
Infrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
GenStore Archive Cabinet
GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 Two GenStore Archives shown mounted on optional table stand. 2 Contents Getting Started... 4 Using this Manual...4 Safety Precautions...4
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
NI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module
DATASHEET NI 9423 8-Channel Sinking Digital Input Module 8-channel, 100 µs digital input 24 V logic, sinking digital input Compatible with NI CompactDAQ counters 250 Vrms, CAT II isolation 10-position
Hardware Manual RM CANview Ethernet
Hardware Manual RM CANview Ethernet Table of Contents 1 Legal Regulations...3 2 About the Device...4 3 Disposal...4 4 Important Information for Using CANview Ethernet...5 4.1 How to Open the Protection
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
ADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
Model 1756 Test Lead Kit
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 1756 Test Lead Kit Gerneral Purpose Test Lead Information Description These test leads allow you
PAR Tablet 10 Quick Start Guide
ParTech, Inc. 8383 Seneca Turnpike New Hartford, NY 13413 p.800.458.6898 www.partech.com PAR Tablet 10 Quick Start Guide PN 770505503 This material has been created in order to accommodate a wide range
is then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection
How To Run An Nport I5000A Device Server
NPort IA5000A Series 1, 2, and 4-port serial device servers for industrial automation Enhanced surge protection for serial, LAN, and power 2 KV isolation for serial signals Rugged screw-type terminal blocks
UniStream CPU-for-Panel
UniStream CPU-for-Panel Installation Guide USC-P-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for industrial automation. This guide provides basic
USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018
USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and
Power supply unit Model: PAC-SC50KUA
Building Air Conditioning Control System Power supply unit Model: PAC-SC50KUA Installation Manual Contents 1. Safety precautions... 1 2. Product feature... 2 1. Specification... 2 2. Appearance... 2 3.
Mitel DECT Base Stations
Mitel DECT Base Stations On-site Mobility for Professionals The Mitel BS300 range of base stations offers a variety of coverage patterns to suit different situations. By choosing the right mix of base
Redundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
Wall-Mounting your HP computer. User Guide
Wall-Mounting your HP computer User Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should
Server Rack Commissioning
Server Rack Commissioning English 1.0.0 / 2015-04-23 Information about Copyright, Trademarks, Design Patents 2015 Dallmeier electronic The reproduction, distribution and utilization of this document as
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
AC-115 Compact Networked Single Door Controller. Installation and User Manual
AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION
FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
