1 Number: Sample Natural Ventilation Application Mechanical Installation at Jewellery Business Kuyumcukent
2
3 President s Overview Owner on Behalf of TTMD: Gürkan Arı Responsible for Publication: Murat Çakan Responsible Editorial Manager: B. Hakkı Buyruk Zeki Aksu Tuba Bingöl Altıok Yalım Atalay Suat Arzık Abdullah Bilgin Şaban Durmaz Göksel Duyum Artuğ Fenercioğlu Devrim Gürsel Hasan Heperkan Kahraman Albayrak Ahmet Arısoy İbrahim Atılgan Erdinç Boz Aytekin Çakır Celalettin Çelik İrfan Çelimli Kevork Çilingiroğlu Fatma Çölaşan Nilüfer Eğrican Hüseyin Erdem Serper Giray Gülden Gökçen Ersin Gürdal Serdar Gürel Murat Gürenli Hüseyin Günerhan Arif Hepbaşlı Hasan Heperkan EDITORIAL BOARD ADVISORY COMMITTEE CONTACT TTMD Head Office Bestekar Sk. Çimen Apt. No:15/2 Kavaklıdere/Ankara Tel: Faks: Web: E-posta: [email protected] Ender İren Atilla Kantarman Eren Kalafat Onur Koca Cafer Ünlü Güven Öğüş Nazif Özakıncı Züleyha Özcan Erdal Taştekin Birol Yavuz Akdeniz Hiçsönmez Ömer Kantaroğlu Engin Kenber Abdurrahman Kılıç Birol Kılkış Olcay Kıncay Ömer Köseli Rüknettin Küçükçalı Celal Okutan Baycan Sunaç Numan Şahin Macit Toksoy Haşmet Türkoğlu Gönül Utkutuğ Abdülvahap Yiğit Tuncay Yılmaz Zerrin Yılmaz Dear colleagues, The concrete impacts of climatic problems triggered by increased environmental pollution due to intensive use of technology and energy in line with modern living style are felt remarkably by modern people. We have to draw necessary lessons from the emerging problems and their impacts without wasting any further time, and exert efforts to stop this trend and take serious measures using our own mind and consciousness. Otherwise, the growing imbalance in nature will inevitably cause even greater problems for mankind. During the last century, mankind headed towards easy solutions in the building sector due to the readily available cheap energy, exaggerated the artistic dimensions of the business, and abandoned the ecological, energyefficient and environment friendly building style. Today, mankind understands that energy resources are not infinite, and the increased global warming and impacts due to intensive consumption have directed mankind to new quests. People of the next century will most probably not use fossil fuels, even if they are available, and will have to meet their needs largely from renewable energy resources. In order not to get caught unprepared, we have to acquire this awareness now and create and introduce the infrastructure for new and renewable technologies. I hope the symposium brings about successful results for our colleagues, industry and country. Gürkan ARI Chairman of Executive Board TTMD 1 Production ASMEDYA Birlik Mah Sok. 5/2 Çankaya / ANKARA Baskı/Printing: Dumat Ofset Distributed throughout Turkey. According to the Turkish Press Laws, the journal is considered to be local periodical.
4 Turkish Society of HVAC & Sanitary Engineers Our Activities Turkish Society of HVAC and Sanitary Engineers (TTMD, Türk Tesisat Mühendisleri Derneği) was founded by Mr. Celal OKUTAN and his friends in 1992 under the title of, Association of HVAC and Sanitary Engineers ( Tesisat Mühendisleri Derneği ) to develop HVAC and sanitary engineering, and to earn the sector the respect it deserves. In 1997, the word Turkish was added before the title and a significant step towards becoming a national association was taken. The Association Economic Enterprise was founded in TTMD regularly holds an International HVAC+R Technology Symposium once every two years, and an annual workshop to discuss a selected topic in detail, participates in domestic and overseas fairs and symposia in the sector, and publicizes and supports such activities. TTMD also publishes books for professional development, and a bimonthly journal addressing the sector with the title TTMD Dergisi (previously TTMD Bülteni for 35 issues). In addition, an English issue is published annually to promote our sector overseas. On the other hand, training programs and seminars are held by our Regional Offices to improve the service quality of our colleagues. Our society tries to facilitate forming of bonds among our colleagues by bringing them together in various platforms, in addition to making a significant contribution to the sector by improving the quality of on-the-job training, which is among its purposes of foundation. TTMD has become a member of ASHRAE (American Society of Heating and Refrigeration Engineers) in 1997, of REHVA (Federation of European Heating and Air Conditioning Association) in 2000, and of CLIMAMED (Joint Organization of HVAC&R Associations of France, Italy, Portugal, Spain) in TTMD develops and supports R&D projects within the framework of university-industry cooperation, takes active part in the preparation of standards and regulations, cooperates with public bodies in the preparation of regulations thus contributing to their conformity with the norms, develops and operates national and international projects (EU, FCO, etc.), and continues its publishing and educational activities in the sector. TTMD performs various activities related to installation in line with its charter, and thus contributes to the public good. Some of the activities of the society performed with this aim are as follows. Realizing knowledge and technology transfer, Contributing to the efficient use of energy in our country, Improving knowledge accumulation and knowledge sharing in the sector and thus contributing to the building of better buildings and plants, Promoting our Country overseas in its own sector, Representing our colleagues in international platforms and following the developments closely, Contributing to the training and research of our colleagues offering professional services, newly graduated engineers, and students willing to develop their skills in this profession in application field, and contribute to knowledge and technology transfer, Providing the necessary communication and discussion enviromnent, Contributing to the research undertaken in universities and research centers concerning our profession and improving the university-industry cooperation, Publication of journals, books, and manuals containing correct and contemporary information on the installation sector, and the establishment of Rules of Conduct, Contributing to the development of the country as we do our profession, Creating healthy, safe, hygienic, comfortable, in a word, livable environments in different buildings in which people spend about % of their times, Generating energy-efficient and environment-friendly solutions and cooperating on this issue, Working in coordination with other professional and expertise groups. TTMD Management Board History of Presidency Gürkan Arı President M. Bülent Özgür Vice President Baycan Sunaç Vice President Hırant Kalataş Vice President Bünyamin Ünlü General Secretary Murat Gürenli Treasurer Abdurrahman Kılıç Member Ömer Köseli Member Güniz Gacaner Member Kemal Gani Bayraktar Member Tuba Bingöl Altıok Member Sarven Çilingiroğlu Member Ramazan Yazgan Member Founding Honorary President Celal Okutan 1 st Term - Celal Okutan 2 nd Term - Numan Şahin 3 rd Term - M. Serdar Gürel 4 th Term - Ömer Kantaroğlu 5 th Term - Engin Kenber 6 th Term - B. Erdinç Boz 7 th Term - Hüseyin Erdem 8 th Term - Abdullah Bilgin 9 th Term - Cafer Ünlü 2 Representation Metin Karabacak Adana Züleyha Özcan Ankara Ayşen Hamacıoğlu Antalya İbrahim Akdemir Bursa Tefik Demirçalı Denizli Özcan Türkbay Eskişehir Göksel Duyum İstanbul İbrahim Üstün Tatlıdil İzmir Necdet Altuntop Kayseri İlhan Tekin Öztürk Kocaeli Öner Boysal Konya Orhan Cazgır Samsun Mustafa Eyriboyun Zonguldak International Memberships American Society of Heating, Refrigerating and Air-Conditioning Engineers Federation of European HVAC Associations Climamed
5
6 Contents 3 President s Overview 6 NEWS 6 English Program Symposium TTMD 20 Years of Age 15 TTMD Projects: Green Careers 16 Full Support to the Private Sector in Transition to Low-Carbon Economics: Climate Platform 4 16 The Concept of Sustainable Consumption and Production (SCP) and the Project of SCP Turkey 16 HIP Work Continues under HIP Project
7 Contents 17 Aqua Conserver First Step Taken in Aqua Conserver Project 17 TTMD in Climamed Congress TTMD In ICHVAC-3 21 ARTICLE 21 Sample Natural Ventilation Application Sarven Çilingiroğlu 5 33 Mechanical Installation At Jewellery Businesses Kuyumcukent Kani Korkmaz
8 News English Program Symposium
9 News HALL A April 30, Monday 08:30-09:45 REGISTRATION 09:45-10:45 OPENING CEREMONY 10:45-11:00 Coffee Break Looking at İstanbul or Seeing İstanbul! 11:00-11:45 Opening Conference: Sunay Akın Chairman: Numan Şahin 11:45-12:30 HALL B Future Energy Concepts For Buildings and Districts - From Energy To Exergy Invited Speaker: Gerhard Hausladen 12:30-14:00 Lunch 14:00-15:40 14:00-14:20 14:20-14:40 14:40-15:00 15:00-15:20 Session - 1A - 1: Technical Session: Energy Efficient Buildings Chairman: Engin Kenber Importance of Dynamic Energy Modelling In Energy Efficient and Green Structure Design A. Zerrin Yılmaz, Ece Kalaycıoğlu, Alpay Akgüç, Meltem Bayraktar Evaluation of Environmental Performances and Energy Efficiency Projections In The Construction Industry In Turkey Taner Soner, M. Ziya Sögüt Green Buildings: Barriers, Opportunities, Supporting Policies and Creating Demand In The Transformation Process of The Construction Industry Çağla Pınar Utkutuğ, Gönül Utkutuğ Potential Customer Approach to Green Housings: A Survey in Ankara Çayyolu Çağla Pınar Utkutuğ, Sanem Alkibay, Zeliha Eser Session -1B - 1: Technical Session: Energy Efficient Buildings Chairman: Erdinç Boz Energy Efficient Double Shell Curtain Wall Systems Gözde Çakır HVAC Applications In Elliptical Architectural Structures Coşku Cengiz, Şenol Kılıç Plumbing Systems In Light Steel Frame Constructions Semih Göksel Yıldırım Building Material Use In Energy Efficient Structures Çiğdem Tekin 15:20-15:40 Master Project Integral Design For Net Zero Energy Buildings Wim Zeiler Energy Labelling and Certification In HVAC Products Yüksel Köksal 15:40-16:00 Coffee Break PANEL: Sustainable Energy Management in Urban Transformations Moderator: Handan Türkoğlu, ITU City and Regional Planning Gerhard Hausladen, The Technische Universität München, Building and Climatization Services Gençay Tatlıdamak, Architect - Advisor, Sustainable Buildings Designer, IB Hausladen Emre Kahraman, City Planner, Municipality of Gaziantep, Department of Housing and Urban 16:00-18:30 Development Seda Müftüoğlu, Architect, Municipality of Gaziantep, Department of Housing and Urban Development Uygur Kınay, Ministry of Environment and Urbanism, General Directorate of Professional Services, Department of Energy Efficiency Aynur Şule Sümer, Municipality of Kadıköy, Head, Department of Environmental Protection and Control 18:30-20:00 OPENING COCKTAIL - Wow Hotel & Convention Center 7 In Hall A, there will be simultaneous translation from Turkish to English and English to Turkish.
10 News 09:00-10:40 May 1, Tuesday HALL A HALL B Session-2A-1: Technical Session: Energy Session-2B-1: Technical Session: Energy Efficient Buildings Efficient Buildings Chairman: Nilüfer Eğrican Chairman: Serdar Gürel 09:00-09:20 From Passive House Through nzeb To Energy Plus Buildings, Some Dutch Examples Wim Zeiler Energy Use During The Lifespan of A Wooden Frame Building Hüseyin Günerhan, Burak Hozatlı 09:20-09:40 09:20-09:40 09:40-10:00 10:00-10:20 Active Roof Cooling By Floating Water Wim Zeiler, Derek Vissers Your Green Compass: Environmental Indicators M. Selçuk Ercan Sustainability = MEPS + Assuring Compliance Through Third Party Certification James Walters Is The UK s Zero Carbon Standard For Housing a Solution For CO2 Reduction In Turkey? Passivhaus Standard as a Means to Achieving Zero Carbon In Istanbul Tuğba Salman Gürcan, Sofie Pelsmakers 10:20-10:40 Coffee Break 10:55-12:40 Session-2A-2: Technical Session: HVAC Systems and Equipment Chairman: Cafer Ünlü HVAC Application In Industrial Buildings İbrahim Karakaş, Zozan Türkgenç Energy Management and Analysis of Energy Saving Potentials On Site M. Ziya Söğüt, İnanç Cahit Güremen, Hakan Kabalar Integrated Project Management In Mechanical Pipework Applications Hasan Acül 10:55-11:40 11:40-12:00 12:00-12:20 12:20-12:40 Energy Efficiency of Air Conditioning And Ventilation Systems Invited Speaker: Olli Seppanen Physical Modeling of Concrete-Core-Radiant Cooling System For Upper-Egypt Climates Ahmed A. Medhat A. Fahim Mircomachined Metal Oxide Semiconductor Gas Sensor Modules Used For Comfortable, Energy-Efficient Demand-Controlled Ventilation and Building Monitoring Simone Herberger, Heiko Ulmer Synchronicity Factor In Air Conditioning of Multi - Storey Carparks Abdurrahman Kılıç 12:40-14:00 Lunch 8 In Hall A, there will be simultaneous translation from Turkish to English and English to Turkish.
11 News 14:00-16:00 14:00-14:20 14:20-14:40 14:40-15:00 Session-2A-3: Technical Session: HVAC Systems and Equipment Chairman: Ahmed A. Medhat A. Fahim Certification and Inspection of Building Materials Republic of Turkey Ministry of Environment and Urbanism, General Directorate of Professional Services, Department of Building Materials Calculation of Temperature Difference (CLTD) Values In The Cooling Load Being Used For Heat Gain Through Building Walls Recep Yumrutaş, Hasan Oktay, Omar Zainal Chilled Ceiling Application In An Office Building of A Global Company Osman Arı Session-2B-2: Technical Session: HVAC Systems and Equipment Chairman: Ömer Kantaroğlu Effect of Non-Domestic Pipework Systems With Different Efficiencies On Water Consumption Levels Ömer Kantaroğlu, Fikret Kantaroğlu Environmental Evaluation of Central and Package Waste Water Treatment Plants In Suburban Areas Levent Alatlı, Ergin Erol,Salih Aliipek, Ercan Özdemir, Burcu Elif Vardar, Levent Çelikko Concerns In Water Supply Lines In Multi-Storey Buildings Arcan Hacıraifoğlu 15:00-15:20 15:20-15:40 15:40-16:00 Adaptive Control Algorithm of Heating System For Lars Low Energy System Radoslaw Gorzenski, Andrzej Gorka, Edward Szczechowiak Energy Evaluation and Comparison Between Different HVAC Systems Ahmet Arısoy New Algorithms For Energy Efficiency In HVAC Systems Michele Albieri, Alessandro Beghi, Luca Cecchinato, Mirco Rampazzo 16:00-16:20 Coffee Break 16:20-18:00 16:20-16:40 16:40-17:00 17:00-17:20 17:20-17:40 17:40-18:00 Session-2A-4:Technical Session: HVAC Systems and Equipment Chairman: Tuncay Yılmaz Energy Conservation In Buildings Firas Aldroubi Performance Analysis of Steam Compression and Adaptive Water Cooling Systems Bülent Orhan, Ali Güngör Energy Savings Through PIBCV Technology For Air Handling Systems - Case Study Tamas Szekely Steam Compression and Adaptive Two-Stage Cooling Cycle Canan Cimşit, İlhan Tekin Öztürk Effect of Control Systems In A Water Cooling System On Energy Efficiency Bekir Cansevdi, Uğur Caner, Ali Güngör Remote Commissioning With Addressable Combined Dynamic Balance Valves and Single Station Balancing (TIB) Method Arcan Hacıraifoğlu Evaluation of Theoretical and Measured Data From The Pumps Being Used In Buildings Heating and Cooling Systems Okan Kon, Bedri Yüksel Improvement In Energy and Water Consumption Levels of Buildings During Operation: A Case Study Z. Cihan Akbulut, Ertuğrul Örs, Celalettin Bozdoğan Session-2B-3: Technical Session: Renewable Energy and Applications Chairman: Halime Paksoy Floor Level Heat Regenerator Design For Structural Applications With Photovoltaic Systems Ahmet Yıldız, Önder Özgener, Leyla Özgener Wind Power Applications In The Buildings Özgün Korukçu Our Country s Position In Energy Production From Wave Energy Emin Akyüz, M.Ziya Yakut, Reşat Selbaş, Arzu Şencan Şahin, İhsan Dostuçok Evaluation of Fresnel Reflector and Collector Application In Isparta İhsan Dostuçok, Reşat Selbaş, Arzu Şencan Şahin, Ahmet Özdemir, Fatih Yılmaz Energy Analysis of Air Heating Sunlight Collectors With Internal Perforated Barriers Hakan F. Öztop, Fatih Bayrak 9 In Hall A, there will be simultaneous translation from Turkish to English and English to Turkish.
12 News 09:00-10:40 09:00-09:20 09:20-09:40 09:40-10:00 10:00-10:20 May 2, Wednesday HALL A Session-3A-1: Technical Session: Indoor Air Quality and Comfort Condition Chairman: Ali Güngör The User In The Loop For Optimal Individual Comfort and Reduced Energy Consumption Wim Zeiler, Derek Vissers, Rik Maaijen, Gert Boxem Numerical Analysis of Comfort Conditions In An Office With Under Floor Heating Özgün Korukçu, Muhsin Kılıç, Jianhua Fan Analysis of Comfort Conditions In A Decisive Evaporative Air Conditioning System İrfan Uçkan, Tuncay Yılmaz, Orhan Büyükalaca, Ertaç Hürdoğan Effects of Decorational Plants On Indoor Air Quality Hakan Şevik, İdil Kanter HALL B Session-3B-1: Technical Session: HVAC Systems and Equipment Chairman: Abdullah Bilgin What is New In DIN Standarts? Can İşbilen, Ummuhan Gencer, Lale Ulutepe Hot Oil Systems Veli Doğan Wrong Facts In Relation To Seismic Protection and Vibration Insulation In Pipelines Eren Kalafat Effects of New EuP Regulations On Turkish Sanitary Industry Çağlar Şakaklı, Derya Çuha 10:20-10:40 10:40-10:55 Coffee Break 10:55-12:40 10:55-11:40 11:40-12:00 12:00-12:20 12:20-12:40 Session-3A-2: Technical Session: Renewable Energy and Applications Chairman: Hüseyin Erdem Thermodynamic Analysis of A Power Cycle Using Above-Critical Carbondioxide Under Water Heater Effect Atilla Bıyıkoğlu, Reşit Yalçınkaya Holistic Approach To Energy Efficient Green Buildings Invited Speaker: Essam E. Khalil Developing A Renewable Energy Selection Toolkit For Istanbul The Istanbul Renewable Toolkit Tuğba Salman Gürcan, Sofie Pelmakers Sustainable Energy Use In The Building By Aquifer Thermal Energy Storage Halime Paksoy, Bekir Turgut 12:40-14:00 Lunch INTEGRATED DESIGN IN BUILDING WORKS- HOP DIFFERENT DISCIPLINES OVERVIEW OF INTEGRATED DESIGN Administrator: A. Zerrin Yılmaz, Süleyman Akım, Göksel Duyum Speakers: A. Zerrin Yılmaz (BinSimDer-IBPSA), Ayşe Hasol (TSMD), Abdullah Bilgin (TTMD), Berrin Yavuz (ETMD), Ömer Yalçın (Carrier System Design 10 In Hall A, there will be simultaneous translation from Turkish to English and English to Turkish.
13 News 14:00-16:00 14:00-14:20 14:20-14:40 14:40-15:00 15:00-15:20 15:20-15:40 15:20-15:40 Session-3A-3: Technical Session: Modelling and Softwares Chairman: Bülent Yeşilata Numerical Modeling of Air Flow Regimes Inside Building Light Shafts Ahmed A. Medhat A. Fahim Numerical Investigations of Flow Patterns and Thermal Comfort In Air-Conditioned Lecture Room Taher M. Abou-Deif, Mahmoud A. Fouad, Essam E. Khalil Developing a Web Based Software For The Calculation of Cooling Load For The Buildings In Turkey Azmi Aktacir, M. Akif Nacar, Bülent Yeşilata, M. Emin Tenekeci, Burak Yenigün, Emrah Yaka Adiabatic Humidification and Cooling As An Alternative Axel Zedina Determining Conduction Time Series (CTS Coefficients By An Analytical Approach For The Calculation of The Looling Load For The Buildings Burak Yenigün, Azmi Aktacir, Bülent Yeşilata, Emrah Yaka Adiabatic Humidification and Cooling As An Alternative Axel Zedina INTEGRATED DESIGN IN BUILDING WORKSHOP 14:00-14:50 INTEGRATED DESIGN AND PROBLEMS OF DESIGNERS 15:10 16:00 SUGGESTIONS AND GOALS 15:40-16:00 Coffee Break 16:00-18:30 Forum: Future of HVAC Systems? Aqueous Systems, Full - Air Systems and DX Systems Director: Ahmet Arısoy (Only registrated participants can attend to the Forum) 20:00 CLOSING DINNER- Kör Agop Restaurant, Kumkapı Please ask Registration Desk For Tickets. In Hall A, there will be simultaneous translation from Turkish to English and English to Turkish. 11
14
15 SPONSORSHIP A SPONSORSHIP B We are expressing our sincere gratitude for your valuable contribution.
16 News TTMD 20 Years Of Age 14 Turkish Society of HVAC and Sanitary Engineers was founded by Mr. Celal OKUTAN and his friends in 1992 under the title of Associations of HVAC and Sanitary Engineers to develop HVAC and Sanitary engineering, and to earn the sector the respect it deserves. In 1997, the word Turkish was added to the title and a significant step towards becoming a national association was taken. The Association Economic Enterprise was founded in TTMD regulary holds an International HVAC+R Technology Symposium once every two years, and an annual workshop do discuss a selected topic in detail, praticipates in national and international fairs and symposia in the sector, and publicizies and supports such activities. TTMD also publishes boks for proffesional development, and a bimonthly journal addressing the sector with the title TTMD Journal (previously TTMD Bülteni for 35 issues). In addition, an English issue is published annually to promote our sector in an international level. On the other hand, training programs and seminars are held by our Regional Offices to improve the service quality of our colleagues. Our society tries to faciliate forming of bonds among our colleagues by bringing them together in various platforms, in addition to making a significant contribution to the sector by improving the quality of on-the-job training, which is among its purposes of foundation. TTMD develops and supports R&D projects within the framework of university-industry cooperation, takes active part in the preparation of standarts and regulations, cooperates with public bodies in the preperation of regulations thus contributing to their conformity with the norms, develops and operates national and international projects (funded by EU, FCO,etc.), and continues its publishing and educational activities in the sector. TTMD has become a member of ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) in 1997, of REHVA (Federation of European Heating and Air Conditioning Associations) in 2000, and of CLIMAMED (Joint Organization of HVAC&R Associations of France, Italy,Portugal, Spain) in The objectives of TTMD include; first and foremost, contributing to the training and research of our proffesional colleagues, fresh graduates, and students willing to develop their skills in this profession in application field; contributing the knowledge and technology transfer; providing the necessary communication and discussion opportunities; contributing to the research undertaken in universities and research centers concerning our sector; and improving the university-industry cooperation. Publication of Manuals containing correct and contemporary information on the installation sector, and the establishment of Rules of Conduct are also among our main objectives. Keeping these up-to-date is the responsibility of our dynamic and concerned Committees and Commissions always in operation. Contributing to the development of our country as we do our proffesion, and in this context creating healthy, safe, hygienic, comfortable, in a word, livable environments in different buildings in which people spend about 80-90% of thier times; generating energy-efficient and environment-friendly solutions using the opportunities offered by the nature; working in coordination with other professional and expertise groups.
17 News TTMD Projects: Green Jobs TTMD s Project Training Youth for Green Jobs Completed The Project for Training and Ensuring the Employability of Youth on Energy Efficiency in Buildings (Training Youth for Green Jobs) executed by Turkish Society of HVAC and Sanitary Engineers between 01 December 2010 and 30 November 2011 under the European Union s Youth Employment Promotion Grant Program has been successfully completed. Under the project executed concurrently in Erzurum, Kayseri and Samsun, very intensive project activities including Project Evaluation Meetings, Press Conferences, Receipt and Evaluation of Trainee Applications, Implementation of Theoretical and Applied Training Programs, Energy Efficiency Information Days have been carried out as from 10 December The project activities continued with Energy Efficiency Awareness Week, Matching and Certificate Award Ceremony in the second, third and fourth weeks, and finally the project was concluded with evaluation and closing meetings held in Ankara with the participation of Project Partners and Participants. Applications from the graduates of undergraduate programs, vocational higher schools and vocational secondary schools who have not been employed yet or who have been employed but are not working currently have been accepted for the training programs organized under the project on a priority basis. A total of 156 trainees, 52 from each province, participated in the training programs, which covered such subjects as heat insulation, heating and cooling systems, HVAC systems, lighting systems, electrical equipment, solar power, etc. The training programs provided most current theoretical and applied technical information fort he efficient use of energy. The programs particularly covered the relevant legislation, labor safety, entrepreneurship and business plan preparation for the trainees who want to start their own businesses. Besides the training programs, seminars and information meetings were organized as part of the activities intended to raise the level of public awareness and knowledge about energy efficiency in the provinces covered by the project. Furthermore, visually designed stands were established in city centers, and brochures and promotional materials were distributed to local people. The trainees and other specialists took part in the stands and answered the questions of people and thus contributed to raising the level of public awareness. The project was implemented in full coherence with the project partners including Erzurum Kazım Karabekir Technical and Industrial Vocational Secondary School, Kayseri Mimar Sinan Technical and Industrial Vocational Secondary School and Samsun Atakum Technical and Industrial Vocational Secondary School as well as the officials and specialists from the project participants who took active part in the theoretical and applied training sessions, including İzocam Ticaret ve Sanayi A.Ş., Testo Elektronik ve Test Ölçüm Cihazları Dış Tic. Ltd. Şti. and Vaillant Isı Sanayi Ticaret Ltd. Şti. 152 out of 156 trainees (97.4%) who received 132 hours of theoretical and 192 hours of applied training in their respective fields of specialization succeeded in the exams held at the end of training and received their certificates in a ceremony. The successful trainees were introduced to the employers active in this sector through a matching activity, in order to contribute to their employment. 36 trainees certificated following the completion of theoretical and applied training programs were placed to jobs. A web page was created to introduce all activities carried out under the project and the trainees who participated in the training programs. ( 15
18 News Full Support to the Private Sector in Transition to Low-Carbon Economics: Climate Platform With the Climate Platform to be founded as part of the Development of Climate Change Initiative in the Turkish Business World project with the cooperation of the Turkish Society of HVAC and Sanitary Engineers (TTMD) and the Regional Environmental Center (REC), creation of a sustainable platform to improve the lobbying and participation abilities of the Turkish Business World in national and international levels is aimed, as well as translation to Turkish of an international training program to develop the capacity of Turkish firms in the field of calculating greenhouse gas emissions. Detailed information about the Climate Platform can be found at The Concept of Sustainable Consumption and Production (SCP) and the Project of SCP Turkey The project team which includes, among others, the Turkish Society of HVAC and Sanitary Engineering (TTMD) and the Technology Development Foundation of Turkey (TTGV), which is one of the 4 national contact points designated as part of the Partnering to Enhance Civil Society Organizations Contribution to Research in Sustainable Consumption & Production project, which is supported by the 7th Framework Program and run under the short title of CSOContribution2SCP (Action Town), aims run a pilot project to publicize the concept of SCP in Turkey, increase consciousness, and improve the relations between the partners. Detailed information can be found at 16 HIP Work Continues under HIP Project One year has passed in the HIP Project, which is being executed by 11 Institutes and SMEs from 6 countries (UK, Ireland, Spain, Norway, Turkey), including Turkish Society of HVAC and Sanitary Engineers. Under the project originally named Project for development of low-cost, lightweight highly insulating polymers for refrigerated transport, heating and cooling installations, project progress is being supervised through quarterly meetings. Under the project which will develop a new class of high internal/natural-phase emulsion-based polymer insulation material, although some materials have been used in many applications, materials that have never been used in circumstances requiring high performance will also be used. In such materials, it is possible to easily control porosity, pore sizes, distribution and mechanical features. For these reasons, calorific characteristics of the material can be secured low-cost production processes. Within the framework of the project to last 3 years, SMEs are coming together under the sub-heading of Partnership Research Projects for SMEs under the 7th Framework Program, and executing the project with a budget of Euro 2.6 million. The next meeting under the project will be held in London and will be hosted by TICA (Thermal Insulation Contractors Association). Detailed information about Project HIP is available at
19 News Aqua Conserver First Step Taken in Aqua Conserver Project water treatment and heat recovery system that can be commissioned following minor modifications, as may requested by the citizens in the EU member and candidate states, building on the concepts of energy and water economy. Turkish Society of HVAC and Sanitary Engineers is taking part in one more international project, following the project Training Youth for Green Jobs which was completed in The project inception meeting titled A novel and combined domestic grey water treatment and heat recovery system suitable for cost effective installation in 90% of European households: AQUACONSERVER was held in Istanbul on 05 January 2012 and was hosted by TTMD. The project is supported under the 7th Framework Program of the EU and includes TTMD as a member of project consortium. The Project being executed by the UK Health and Environment Research Institute (HERI) aims at introducing, by mid-2014, a low-cost domestic grey Twelve institutes, SMEs and NGOs including TTMD (the UK Health and Environmental Research Institute-HERI, The Environmental And Sustainable Construction Association-EASCA, IGP srl, Logrotex SA, Convex Electrical Ltd, Haswell Moulding Technologies Ltd, Aqualisa Products Ltd, Tecniberia, Asociacion Espanola De Empresas De Ingenieria, Consultoria Y Servicios Tecnologicos-TECNIBERIA, Novamina Centar Inovativnih Tehnologija Doo-NOVAMINA, Instituto De Biologia Experimental E Tecnologica-IBET, Polska Korporacja Techniki Sanitarnej, Grzewczej, Gazoweji I Klimatyzacji-PKTSGGK), from 8 countries (Croatia, UK, Ireland, Spain, Italy, Poland, Portugal and Turkey) have come together for this project with a budget of Euro 1.9 million, which was accepted under the Partnership/ Cooperation Projects for SMEs component of the 7th Framework Program that will last 3 years. Detailed information about AquaConserver Project is available at TTMD in Climamed Congress 2011 The congress took place in Casa de América, one of the most prominent examples of Madrid s architectural heritage, under the auspices of Spanish Technical Association of Air Conditioning and Refrigeration (ATECYR) with the participation of many engineers and academicians from Spain, Italy, France and Turkey. Turkish HVAC and Sanitary Engineers Society President Gürkan Arı participated the opening speech on the first day together with French HVAC and Sanitary Engineers Society (AICVF) President Bertrand Montmoreau, Italian HVAC and Sanitary Engineers Society (AICARR) President Renato Lazzarin, Spanish Technical Association of Air Conditioning and Refrigeration (ATECYR) President Juan Jose Quixano, Spanish Energy Conservation and Energy Diversity Institute (IDAE) 17
20 News President Alfonso Beltran and Climamed 2011 President Julio Cano Lacunza. Gürkan Arı informed about Turkish mechanical and HVAC sector and building energy performance strategies in Turkey. 39 technical papers were presented on the topics such as energy efficiency, renewable energy sources, indoor air quality, energy performance assessment, etc. 10 of these papers were presented by Turkish experts. Turkey participated the Congress actively with nearly 40 participants and as a country with a high level of participation had the second highest number of paper submissions after host country Spain. The next CLIMAMED Congress will be held in Turkey in 2013 to be hosted by TTMD. 18 TTMD in ICHVAC-3 With the collaboration of United Nations Environment Programme (UNEP) and Turkish Society of HVAC and Sanitary Engineers (TTMD), the Third International Conference on Heating Ventilating and Air Conditioning (ICHVAC-3) was being held in Tehran, the capital of Iran, on May TTMD President Gürkan Arı and Board Member Dr. Kemal Gani Bayraktar participated the conference on behalf of our organization. Gürkan Arı introduced TTMD and its activities and shared information about HVAC Sector in Turkey at his opening speech. Moreover, he summarized that how energy efficiency and new regulations affect the development of the sector by presenting data with examples. TTMD Committee made contacts with Iran within the scope of the conference, got together with Director of School of Mechanical Engineering Sharif University
21 News of Technology, Prof. Dr. Mohammad H. Saidi and got informed about 6 departments in the school while visiting research laboratories. Different departments such as Biomechanics, Ocean Engineering, Manufacturing and Production, Energy Transformation, Applied Mechanics, Mechatronic were examined and potential collaborations were studied within the scope of the visit. The school has 40 different laboratories. Out of 1200 students, there are 112 Phd students and 400 MSc students in the school. The school has built strong connections with the industry and 14 out of 43 personnel work in department of Energy Transformation. Later in a meeting with Energy Engineering School Director Prof. Dr. Moustafa Sohrabpour and his team, information about master s and doctorate programs for System Engineer, Environmental Engineers, Energy Engineers and Nuclear Engineers was presented. The institutions got to know each other and potential collaborations were discussed. Same day in the afternoon Sharif Energy Institute under the direction of Prof. Dr. Yadollah Saboohi was visited. The institute works especially on commercializing new technologies and offers master s and doctorate programs. The institute who works in cooperation with public institutions and with the industry focusing on R&D, was introduced in a working meeting and potential collaborations were discussed. 14 workshops were held as well as many technical sessions at the conference. Main conference topics were as follows: At the opening of the conference and the exhibition where TTMD took part with a stand as well, Turkish HVAC+R market was introduced with catalogs and pamphlets that were handed out. Same day in the afternoon a workshop called Energy Efficiency Practices in Turkey was conducted and 3 presentations were given to the conference participants by TTMD committee. Cogeneration and its Applications by Mr. Özay Kas, Shopping Mall Application Model for Heat Pump and Energy Efficiency in Buildings and Passive Approaches by Dr. Kemal Gani Bayraktar were presented at the workshop. Our stand in the exhibition hall was visited by our commercial attaché Mr. Alper Çakıroğlu as well. 84 papers out of 148 had been presented verbally and in written form at the conference which took 3 days with participants more than New design criteria in HVAC&R 2. National codes and standards in HVAC&R 3. Industrial HVAC&R systems 4. New emerging technologies in HVAC&R systems 5. Indoor air quality and comfort conditions 6. Environmentally friendly air-conditioning, cooling and refrigeration techniques 7. Energy optimization TTMD committee got together with miscellaneous NGO representatives in the evening of the first day of the conference and evaluated sustainable potential for collaboration in many aspects while indicating the first possible steps. 19
22
23 Article Sample Natural Ventilation Application Sarven Çilingiroğlu Section 1. Development Of Design Strategy: 1. Meeting The System Requirements: Two key factors affecting environmental performance are taken into consideration in the design of Natural Ventilation System. - Ventilation to maintain indoor air quality at the sufficient level - Ventilation in addition to other systems reduces the overheating tendency of buildings particularly during summer months. Natural ventilation strategy must be taken into consideration while designing other systems as well. While designing buildings, natural ventilation must be taken into account. Factors to consider are; - Sufficient acoustic environment: Natural ventilation openings increase sound transmission into indoor spaces from the exterior. Depending on the position of the building, this may be a determining factor. Furthermore, naturally ventilated buildings involve excessive exposed concrete to enhance the thermal capacity of the space. Such large areas must be carefully designed to secure appropriate acoustic environment. - Smoke Control: Because smoke may follow natural ventilation tracts, fire safety system must be able to operate in an integrated manner with natural ventilation system. - Health and Safety: Most natural ventilation openings will be positioned much higher from the floor plane. Thus, rules of working at height will be taken into consideration in detail Ventilation: The primary objective of ventilation is to maintain indoor air quality at a certain level by eliminating the pollutants in the air or mitigating their impacts. The guidance for ensuring necessary indoor air quality is provided in Approved Document F. Ventilation above the rates provided here is also possible. However, these high values will change the perception of freshness and lead to increased energy costs. Approved Document F includes three strategies for sufficient indoor air quality: (a) Extract Ventilation: Indoor air is extracted for the removal of pollutants, and is replaced by outdoor air. (b) Whole Building Ventilation (supply and extract): It ensures the dilution of other pollutants and mitigation of their impacts. (c) Purge Ventilation: It removes high-concentration pollutants. This high concentration may, for example, be after painting, modification works or due to release of fuel as a result of accident. Purge ventilation is slightly stronger than background ventilation. It both reduces the quantity of high-level pollutants and extracts heat from the setting. It also facilitates thermal comfort during summer months. The rate for whole building ventilation is given as 10 l/sec per person (in CIBSE Guide A and Approved Document F). This rate has been determined in consideration of the correlation between ventilation quantity and health. Because naturally ventilated buildings cannot ensure a fixed ventilation value, it must be demonstrated that equivalent air quality is secured. To this effect, it must be demonstrated that indoor air quality secured by natural ventilation is the same as indoor air quality secured by 10 l/sec/person fixed ventilation. This calculation and measurement must take into account the times when the building is fully occupied. A similar calculation may also be done for variable ventilation, which is similar to natural ventilation. In both cases, threshold values for outdoor CO 2 concentration and building occupancy rates must be taken equal. The natural method is selected unless the CO 2 rate obtained with natural ventilation is higher than that obtained with mechanical ventilation. Furthermore, the maximum concentration obtained with natural ventilation must not exceed the maximum equivalent value. Indoor air quality (IAQ) calculation tool is provided in the appendix to demonstrate how to make these calculations (See Figure 1.1). 21
24 Article varies by the prevailing seasonal conditions and the thermal comfort condition expectations of people in the building. By estimation, natural ventilation systems may meet heat loads up to W/m 2. If climate change reaches significant levels, this estimated value should be reduced. Adaptation of people to climate changes may keep this value unchanged. Usually, three main factors are taken into consideration in design and operation, to achieve acceptable summer conditions: a- Excessive solar heat gain in indoor areas is prevented through proper solar ray control. b- Internal heat gains must be reduced to reasonable levels. (from human, equipment, lighting) c- During the hottest times in summer months, indoor air temperature may exceed 250C. But, in a well-designed building, temperature may be reduced to tolerable levels through improved air movement and chiller mean radiant temperatures Ventilation Control If natural ventilation is to be applied in a system, the system must allow for a level-controlled ventilation in a certain range. This range may vary from 0.5 ACH (Air Change per Hour) to 5 ACH. Furthermore, it must be possible to fully close ventilation when the building is empty. If people are the primary cause of air pollution, in particular, ventilation may not be done when the building is empty. The system must be designed to prevent discomfort due to draft particularly during winter months, in addition to securing sufficient amount of ventilation. In order to prevent this in offices in particular, air inlet vents must be located 1.7 m above the floor Control of Overheating During Summer Months: Overheating during summer months is the most important factor affecting the feasibility of natural ventilation. The cooling potential of natural ventilation Solar Ray Control: Upcoming CIBSE TM37: It will include detailed information and guidance on improved solar control design and solar control performance. Some measures may be taken to reduce overheating to a certain level. These include; - Window size and direction: This factor relates to the general organization of the building. Shading of windows by surrounding buildings or other parts of the building may reduce solar heat gain. - Painting, shading films and coating (for windows) As a result of advancements in glass technology, solar heat gain has been reduced through special coating applications that do not impair sight but transmit only the rays with certain wavelength. - Jalousie: Interior, interplane or exterior installation is possible. - Projections, Side Wings, Shutters: Such solar controls depend on direction, and may require different types of control on each facade. Furthermore, they affect building aesthetics substantially. The performance of these different systems (individually or collectively) may be quantified through effective
25 Article total solar energy transmission or effective g- values. This value is calculated by dividing the total solar heat gain passing from window or shading elements during hottest times, by solar gain passing from an opening under the same conditions. In addition to potential impacts of global warming, other impacts may also lead to high indoor temperatures. These impacts should also be taken into account while designing natural ventilation. The most important impact is the heat island effect created through the unification of two cities as a result of the expansion of cities. This particularly raises nighttime temperatures. Consequently, it will be more difficult to pre-cool buildings through nighttime ventilation. Detailed information on heat island effect is available in CIBSE Guide A Control of internal loads: There are three important loads. a- Load from humans b- Load from lighting c- Loads from equipment Comfort Expectations While evaluating overheating, the most important step is the determination of acceptable thermal comfort conditions. Thermal comfort varies by the combination of psychology and culture. Acceptable comfort conditions vary by the activity carried out in the indoor area, clothes of individuals, temperatures, air speed and humidity. and thus reducing mean radiant temperature. Reduction of mean radiant temperature satisfies comfort conditions even if air temperature rises in the area. By increasing thermal capacity, the amount of heat the building can store based on every one degree mean radiant temperature increase, and thus the capacity of the area to satisfy thermal comfort conditions is enhanced. Figure 1.3 illustrates the advantage of thermal mass. This figure shows the impact of thermal mass and nighttime ventilation on internal temperature. Temperature differences of up to 5K are observed between a building with light thermal mass and no nighttime ventilation and a building with nighttime ventilation and heavy thermal mass. Naturally ventilated buildings reveal more variable air temperature that buildings with normal ventilation. But this does not necessarily imply less comfort. Perception of comfort may be changed through increasing air movement by help of wider openings during summer months. However, excessive draft should be avoided during this application. As illustrated in Figure 1.2, an air flow of 0.25 m/sec, ensures a decline of 1K in dry bulb temperature. These air speeds may be applied only during summer months, but represent a striking example to demonstrate the impacts of natural ventilation. 23 Nighttime ventilation may be applied to increase cooling benefit. This application is based on the principle of ensuring pre-cooling of building using the relatively low external temperature during nighttime.
26 Article Acoustic Performance The presence of apparent external sound sources is the factor that causes greatest difficulty in the application of natural ventilation. There are two main solutions to this issue: - Vent holes are located on the side far from the source of sound. If the source of sound is traffic, the positioning of these openings on the side without traffic would at the same time ensure clean natural air. - Acoustic curtains may be added to ventilation openings. For schools in particular, it is very important that a good acoustic performance is secured together with natural ventilation. BB93 includes recommendations for ensuring acoustic performance together with natural ventilation. Figure 1.4 demonstrates that ventilation openings with acoustic protection could be integrated with window ledge and circumferential heating. consideration of cooling load that may increase due to climate change or tenant preferences. The projection to be made in this case should include the openings to be left in the floor and ceiling to enable installation of additional systems. The cost of additional flexibility should be compared with the operating and installation costs to be incurred by undue air-conditioning, and the decision should be taken accordingly. b) Zoned mixed-mode This mode considers that different areas of the building serve different purposes of use. Air-conditioning is applied where it is actually needed. Heating and ventilation is applied in areas with low heat gain. This type of an approach is applied to building sections where fixed heat loss and gain is expected throughout the building s lifetime. Such practices may lead to tension among users. The users of two areas with different conditions may think that other group of users have better conditions and may resort to actions to claim their rights. c) Changeover mixed-mode This mode considers that the cooling load of each area may differ seasonally. An example of this is the mechanical ventilation used under very extreme weather conditions (too hot or too cold). Under mild weather conditions, natural ventilation is used. This eliminates the draft effect during winter months. Furthermore, it helps the pre-cooling of building with nighttime ventilation Natural Ventilation and Mixed-Mode The above discussion addresses the conditions required for application of natural ventilation in a building. However, it is not compulsory to ventilate all areas of a building with the same system. Different strategies may be applied at different times for different sections. This is called mixed-mode approach. This is explained in CIBSE AM13 in detail. Various approaches to mixed-mode are outlined below. a) Contingency mixed-mode This system is used if flexibility is needed in the area. Such systems should be designed with due d) Concurrent mixed-mode It ensures concurrent operation of Mechanical and Natural Ventilation. While the mechanical system meets the fresh air need, opened windows or openings help cooling for summer. Furthermore, mechanical ventilation may be turned on for nighttime cooling, and the security problem in natural ventilation may be resolved. Under very hot weather conditions, energy may be wasted as excessive natural ventilation would provide unnecessary fresh air. Figure 1.5 presents a superficial flow diagram for users to be used during selection stage Starting with Design: If natural ventilation is found to be feasible based on the above discussions, a decision needs to be taken as to whether this would be a single type or a mixed-mode system. The next strategy is to proceed with design concept. There are three key steps in the design stage.
27 Article a) Modeling of air flow from inlets to outlets: This model varies by the shape and organization of the building. In addition, the purpose of use of the building and ventilation, and the position of the land it is located on are also effective. For example, is there is a road with busy traffic on one side of the building, it would be unreasonable to locate the air inlets on that side. Air inlets should be located on the other side in terms of pollution and air quality. b) Basic drivers required to be analyzed for obtaining the desired air flow model: While many strategies take wind pressures into consideration, some utilize temperature differences. In some cases, fans may be used to assist these natural forces; a good design should warrant that dominant forces ensure the required flow. c) Sizing of openings to obtain the desired air flow rate and flow pattern: This is performed in three stages. 1. Flow rates are calculated by taking into consideration thermal comfort conditions and air quality. 2. Openings are sized and positioned to ensure these flow rates under design conditions. 3. A control system must be designed so that the system runs automatically at various rates of occupancy and weather conditions. Start No Is max. heat gain higher than W/m 2? IS it possible Yes to decrease it No Temporary No below occupaucy? W/m 2? mixed-mode acceptable? No No Yes Yes Can capacity effects balance temperature and inlet air quality oscllation? Yes Yes Yes No Peak season? Yes Yes Narrow building? No Is it possible to decrease a trium width below 15 m? No Zoned mixed-mode? Mixed-mode ventilation Yes Yes Yes Is this space facing exterior? Yes No Noise and contamination level acceptable? No No Yes Can people adjust varying weather conditation? No Necessary to scrutinize temperature? ±1K Yes Necessary to scrutinize relative humidity? ±10% Yes 25 No No Yes No Is it necessary to use humidification winter months? Yes Natural ventilation Mechanical ventilation Mechanical ventilation and humidification Comfort cooling Full ventilation Figure 1.5: Choice of ventilaiton strategy
28 Article Section 2. Example Building - Tarsus Mall: 1) The mall we designed will be constructed in Tarsus. Total area of Mall: m 2 Area of parking lot: m 2 Sales areas: m 2 Total area of natural ventilation: m 2 Number of rooftop units used in atrium area (single-fan) :4 units Fresh Air Openings for Atrium: 2 m 2 x 20 units = 40 m 2 (Total) The air enters the building from the south part of the ground floor, passes through the 2 m. passage area formed on the facade of the building, reaches the atrium area, and then reaches Floor-1. Dirty air is expelled through the openings on the roof of Floor-1. There are food court areas on the west side of Floor-1, and the air entering the building from the facades reach these areas as well, due to negative pressure in these areas. It is projected that there will bee 2,750 people in the Mall and small stores under worst conditions people x 36 m 3 /h/person (10 l/s) m 3 /h fresh air is needed m 3 /h is needed by fast food areas. Thus, total fresh air need amounts to 120,000 m 3 /h under worst conditions. This need will be supplied through vent holes from net inlet areas of 40 m 2. Accordingly, entry rates are as follows: m 3 /h = 33,33 m 3 /sec 3600 V = 33,33 /40 m 2 = 0,83 m/s.
29 Article 27
30 Article Section 3. Building Simulation: Simulation Infrastructure: The simulation model of Tarsus Mall has been prepared by taking as a basis plans and construction details. The model for the performance evaluation of natural ventilation system has been prepared using the program named <VE> Virtual Environment Version 6.0. Figure 3.1 and Figure 3.2 show and name the zones evaluated. Figure 3.1: Ground Floor Zones 28 Figure 3.2: Floor-1 Zones
31 Article 3. 2 CO 2 Levels Revealed by Simulation: For the identification of fresh air quantities, the ambient CO 2 concentration is taken as a reference. According to ASHRAE Standard , acceptable outdoor CO 2 concentration is between 300 ppm and 500 ppm. Indoor CO 2 concentration cannot be more than 700 ppm higher than outdoor air concentration. Figure 3. 4 Hours for different CO 2 levels in the Mall areas. Figure 3.5 and Figure 3.6 show the hours passed above a certain temperature value separately for stores and mall areas. For example, for the section 0-shop North east 3,023 hours a year pass above 26 ºC, and 4 hours pass above 26.5 ºC. This analysis takes as a basis the period between 10:00 hrs and 22:00 hrs every day. The outdoor concentration taken for simulation is maximum 500 ppm max. Indoor CO 2 concentration is ppm = 1200 ppm. CO 2 levels are given in the figures below. Due to constraints in the modeling program, the outdoor CO 2 concentration actually taken as 500 ppm was accepted as 350 ppm. PPM (Parts Per Million) represents the amount of particles per million. Due to this constraint of the program, CO 2 levels were written 150 ppm less during modeling, and thus close-to-actual modeling of the system was ensured. Figure 3. 5: Hours passed above given temperatures While evaluating CO 2 levels, it should be considered that actual levels would be 150 ppm higher. Figure 3.3 and Figure 3.4 show the annual hours passed higher than each CO 2 level for the stores and mall area. During this analysis, it was assumed that the system operated from 10:00 hours till 22:00 hours during all days of a year. As mentioned above, actual CO 2 values will be 150 ppm higher. For example, for the section 0-shop-north east in Figure 3.3, the CO 2 concentration will be above 1250 ppm for 257 hours annually. Figure 3. 6: Hours passed above the given temperatures between 23 ºC and 30 ºC 3. 4 Conclusion: For the evaluation of the natural ventilation system designed for the adjacent stores ventilated with the natural air supplied from the mall section with the help of the mall and air exhausts, a model was created for Tarsus Mall for a given period of time taking into consideration the pre-calculated heat loads at certain critical points. The stores with ventilation balance ensured only mechanically were evaluated indirectly taking into consideration their impacts on the natural ventilation system. Figure 3. 3: Hours for different CO 2 levels in stores. Figure 3. 4 Hours for different CO 2 levels in the Mall areas. As discussed above, the system was revised to make sure that the cooling coil loads for the stores and corridors are the same as the values given by the mechanical designer on 07 December The thermostat set point for nighttime ventilation during transitional seasons was reduced from 26 ºC to 20 ºC. When corridor temperature exceeds 20 ºC during nighttime, dampers and luminaires will be opened automatically. The clearance of dampers was raised to 40 m² from 30 m². The clearance value for luminaires was not changed. 29
32 Article As a result of revisions, the temperatures in stores does not exceed 26 ºC in general. Thus, the system is adequate to keep the temperature below this level. In the mall area, temperature will exceed 26 ºC for hours. This value is the same as the value before revision. However, hours passed above 28 ºC was reduced below after revision and a significant difference was obtained. High temperature ranges were obtained usually when outdoor air temperature is very high. In general, the CO 2 levels in stores are below 1200 ppm. However, the CO 2 level is above 1200 ppm for 400 to 1100 hours during the time the stores are open. (calculated as 1050 ppm +150 ppm in the table). The CO 2 level declined by more than 10% after revisions. CO 2 level never exceeds 1600 ppm (calculated as 1450 ppm ppm). These concentrations reach the highest value at the weekends, since the loads originating from humans increase depending on the rate of occupancy. Concentrations rise during summer months as well, as there is a decrease in air flow from natural ventilation due to the decrease in temperature difference. In the mall area, CO 2 levels are usually lower than 1200 ppm, however this value is above 1200 ppm for a period of 50 to 160 hours (shown as 1050 ppm ppm in the table). Because loads from humans reach maximum level at the weekends, the CO 2 concentration also reaches maximum level. In addition, given the fact that natural ventilation is a very complicated process, it should be noted that simulations involve uncertainties depending on the behaviors of the people in the mall, even if they are proven to be very close to actual. The wind speeds taken as a reference in the simulations are the mean wind speeds specified for that region. Different wind speeds due to local conditions around the mall may lead to different results. Overall, simulations provide a sufficient reference for the evaluation of system performance. Section 4. Comparison Of Natural Ventilation Systems And Classical System: 1. Initial Investment Costs: 30
33 Article Water Unit Price: 2.6 /m 3 1 kwh = E 31
34 Article Section 5: Conclusion Saving in an area where approximately 13,426 m 2 is naturally ventilated: INITIAL INVESTMENT: OPERATION: (6 months cooling, 2 months heating) Note: Transitional periods not taken into account. There will be a saving to be secured by fans during these periods. For the implementation of such as system that ensures saving from initial investment and operation costs, the feasibility of the system should be tested through simulation programs and it must be implemented of feasible results are obtained. REFERENCES: (1) Natural ventilation in non-domestic buildings: AM 10: 2005 CIBSE (2) Ventilation for Acceptable Indoor Air Quality: ANSI/ ASHRAE Standard (3) SUSTAINABILITY ON BUILDINGS: APPROACHES TO LIFETIME COST, Dr. İbrahim ÇAKMANUS, Mechanical Engineer, MSc, Assoc. Prof. Türkan GÖKSAL ÖZBALTA, Architect, MSc (4) SIMULATION OF NATURAL VENTILATION SYSTEM (TARSUS SHOPPING CENTRE DECEMBER 2009, GRONTMIJ Sarven Çilingiroğlu Mechanical Enginer, MSc (İ.T.Ü.) He was born in 1963 in İstanbul. He graduated from Getronagan High School in 1980 and İ.T.Ü. Mechanical Engineering Faculty in He started with graduate program the same year at İ.T.Ü., and graduated from thee Energy Department in He worked part-time at HONEYWELL company for one year during his graduate education. He completed an internship program of two months at the YORK INTERNATIONAL company in the UK to prepare his thesis on heat pumps in He completed his military service between 1987 and He is currently the general manager of a firm that produces mechanical installations designs and provides supervision and consulting services. He is married, with two children. 32
35 Article Mechanical Installation At Jewellery Businesses Kuyumcukent Kani Korkmaz Abstract Jewelry is the processing of precious metals and stones such as gold, silver and diamonds. During the processing, providing comfort conditions, recovery and discharge of 2-5% precious metals loss as a result of various production methods are significant works to be considered. In the example of Kuyumcukent, unique design criteria of mechanical systems for different sized workshops are composed from local measures and the outcome of operational results of the facility including deviations is presented. Critical points of the applied systems in the new phase are indicated. However some data are excluded due to security restrictions. Location: Istanbul, Yenibosna, Across the Atatürk Airport Land Area: Kuyumcukent Total Area : m² Total construction area : m² 1 ST STAGE : m² 2 ND STAGE : m² 3 RD STAGE : m² 33 General Approach In Istanbul, especially in the region which is known as the historical peninsula and where Topkapı Palace, Hagia Sophia, Grand Bazaar and Sultan Ahmed Mosque are located, more than thousand small and medium sized enterprises have produced precious metals by hand-workmanship for centuries. In recent years, high increase in production and use of new chemicals have caused environmental and production problems. Since businesses are not that organized, it has been not sufficient to control and take technical measures. The plan was to transform this business
36 Article field with employees into a new organized field where job security, healthy work environment, efficient production, environmental awareness and energy-effectiveness are available. Under this planning, gas emissions of existing buildings, chemicals used by these buildings, their production volumes, liquid wastes, metal losses, environmental impacts and water, gas, electricity, heating and cooling consumption rates were measured under the management of Istanbul Technical University s (İTÜ) Department of Environmental Engineering. Then these measurements were evaluated. It has been agreed to make the new building in compliance with traditional production method. Additionally, it has been aimed to make mechanical solutions enable the improvement of business. Results of Measurement Damage of acidic-basic wastewaters to general sewerage system, being out of condition in patches and interference with ground waters and sea waters. Environmental limit values of gas emissions are higher than 200% in some cases. Damage to the historical buildings. By considering these values, liquid wastes were collected from each enterprise with 5 different lines. Then they were connected to the following areas: 1. Acidic waters to the balancing pond of treatment unit Results of Liquid Wastes Measurement Production Units Type of Wastewater Amount (l/kg Processed Gold) Amount (m /day) 34 * Basic wastewaters originating from flue gas washing systems.
37 Article 2. Basic and cyanide water to separate balancing pond 3. Gypseous and detergent waters to the lifting pond 4. Hand-washing and shower waters to the mains after recovery 5. Domestic wastewaters directly to the mains With this method, precious metals (gold, silver, etc.) in melt state in chemical waters and in powder state in cleaning waters have been recovered at 80%. By means of continuous controls, liquid wastes under the limit values of mains system were released to the infrastructure. Results of Gas Wastes Measurement TABLE 1. Features of Wax Melting Furnace Stack TABLE 2. Emission Measurements of Wax Melting Furnace TABLE 3. Measurement Results of Adjustment House Using Electropotentiometrical Titration Method Features of Fume Cupboard Stack Emission Measurements TABLE 4. Emission Measurement Results of Hydrochloric Acid (HCI) Processing Features of Fume Hood Stack Emission Measurements Exhaust System Gas emissions at the workshops determine the ventilation system. As an example to this statement, features of wax melting furnace stack, emission values of fume hood stack and measurement results of fume cupboard stack are given in Table 1, Table 2, Table 3 and Table 4. Since it has been not possible to determine the final production conditions of workshops, a diversity factor was used again and a vertical channel line was established for each exhaust. Vertical lines carry over exhaust emission from fume hoods of acidic and basic lines in the workshop separately, furnace lines carry over exhaust emissions from furnaces and fume hoods and ambience lines carry over the exhaust of general atmosphere. Acidic, basic and furnace exhausts are closed when they are not in use and therefore, the workshops that are out of use or with no production at that moment produce no emission. Exhaust fans on the roof provide significant energy saving as they have frequency inverter. Also, when required, it prevents deviations in diversity factor. In order to ensure chemical resistance in acidic and basic lines, CTP lines will be used and furnace lines will be made of black sheet for temperature resistance. The fans installed on the roof of each vertical shaft will be made of PVC. As a rule, treatment, filtration and washing operations of gas emissions at the production unit of each workshop will be made at the absorption unit at the end of each fume hood, they will be processed by using NaOH in acids and water in basics and will be connected to main lines. However, it is assumed that faults and failures may occur because of technical reasons and users and therefore, exhaust airs extracted from these lines are released from the top end of penthouse. Also, necessary reservation areas are created for central secondary treatments in case the values which will be checked through continuous measurements exceed environmental limit values. In acidic and basic lines, condensations occur due to temperature differences and emission concentrations. These condensations are connected to the lines where liquid wastes are collected, by placing drainage inlets under the channels. Heating - Cooling - Ventilation - Hvac Average Conditions in Existing Buildings Building Envelope: Window U-value 4.5 W/ m²k Wall U-value 1.5 W/ m²k 35
38 Article Roof U-value 2.2 W/ m²k Indoor temperature - heating season C Indoor temperature - cooling season C (Split or none) Indoor Air quality: Axial fan and natural directly from window. Data of New Building Window U-value 1.9 W/ m²k Wall U-value 0.35 W/ m²k Roof U-value 0.25 W/ m²k Indoor temperature - heating season 20 C Indoor temperature - cooling season 26 C As a result of measurements and associated load calculations, it is required to draw m 3 /h of air through 125 exhaust aspirators with full load. Drawing such amount of exhaust (8 d/h) indicates the amount of fresh air required to inflow for air balance. Inflowing such amounts by conditioning will cause significant energy consumptions, bigger devices will be required and thus problems related to the shaft height will occur accordingly. As it is known that such exhaust rates do not always require, forcing air will be maintained in 3 stages at peak moments. Air Handling Units 1) Supply of fresh air by means of cellular ventilation and handling units with direct expansion, water-cooled condenser, water heater battery and rotary heat recovery, which also used the air from atmosphere besides acidic and basic furnaces, WC, bath and kitchen. These units will meet their heating requirement from the boiler during the winter and meet their cooling requirement from the DX battery during the summer, cooling units will be placed on top of them and cooling condenser water of scroll compressors will be met from closed circuit cooling towers. Cooling units will be 407C 410A. Forcing air will be able to operate with 100% outdoor air during transit seasons and in this case, the air will directly release out the exhaust. When required, it will be able to operate at night and proper outdoor conditions and summer load inaction of the building will be taken out. Total clean air rate of these units is m 3 /h. Normally, this value is equal to d/h air change and 8-10 lt/s values. Fresh air is not exhausted to the general volumes and therefore, workshops are left under negative pressure. This occurs for two reasons: *) Workshops prevent the release of precious metal powders. *) Preventing the release of production gas in an uncontrolled way. 36 Figure 1. Principle Scheme of Fresh Air Facility
39 Article 2) From ceiling or upright WSHP units, These units will have outdoor air bleeding feature at 20-25%, and there will be louver board and filter on outer wall of each workshop to get fresh air. Heat pumps will have filter, automatic balance kit, condensate drainage connection, micro-processor based terminal box room or channel type heat sensitive acoustic isolated fan section and separated from compressor with acoustic isolated panel, and with single cooling system on units with lower than R410A or R407C gas and 15 kw cooling and with double cooling system on units with higher than foregoing values, and they will be able to operate at water intake temperatures between C and air intake temperatures between +4,4 C +35 C, the fans of double circuit units will be speed adjustable through fan engine and they will have EN filter, automatically perform room temperature and security control. Water intake-outlet temperatures: 30/37 C during cooling - 20/22 C during heating; air intake temperature: 26 C during cooling, 21 C during heating, and maximum 15 C of outlet temperature. 3) Outdoor direct air intake from forcing fans of doublewalled fume hoods used in production Fume hoods will be double-walled. Forcing fan will also operate when engine-driven dumper with plastic CTP body on the suction channel and it will release air to the inlet of fume hood from its outer wall. Users will be able to check on the front section of furnace the heat recovery and average winter temperate with electrical coil. By this way, average minimum fresh air will be supplied from the fresh air plant in case of unavailability of acidic, basic and furnace emissions in the workshops. Such amount will be sufficient to meet 8 lt/s of fresh air need of 25 people. The air will be provided to each user by means of CAV units at the entrance of workshops and return air will be supplied from return channel of ambient air. When exhaust line of furnace is opened, WSHP fresh air suction dumber will be opened automatically. When acidic-basic line is opened, outer air fan will operate and feed fume hoods and furnaces with direct outdoor air. The air WSHP units receive will 37 Figure 2. Principle Scheme of Standard Workshop
40 Article be mixed with conditioned air from fresh air plant in all cases. Fresh air plant will supply air at 25 C during summer and 20 C during winter. WSHP units will condition the room by recirculation of fresh air and ambient air. It is required to use micron filters both at suction of re-circulated air and transforming ambient air into fresh air. During the operations in jewelry business, precious metals mix with powders, and they gather round under culverts, channels, clothes and sheets in significant amounts. Users pay high attention to this issue and when they observe a powder leakage to the mains, they close all culverts and cause the failure of entire air balance. In addition to the filters, air speeds must be evaluated carefully. The appropriate speed at suction inlets is m/s average. In case it is required to recover extracted air and release sufficient amount of air from existing boilers, WSHP units in the workshop together with closed towers will meet heating-cooling requirement of entire system without needing any cooling group, by aiming the use of system when the temperature in the condenser of fresh air is appropriate and supplying heating battery load. The availability of production load during winter and transit seasons enables free cooling from closed towers. In conclusion, besides improving comfort conditions specified under the transformation of production, a new structure where 54% of former business finance is provided for producers has been introduced without changing traditional production methods. 38
41
42
43
44
In Hall A, there will be simultaneous translation from Turkish to English and English to Turkish.
April 30, 2012 - Monday HALL A HALL B 08:30-09:45 REGISTRATION 09:45-10:45 OPENING CEREMONY 10:45-11:00 Coffee Break 11:00-11:45 11:45-12:30 Looking at İstanbul or Seeing İstanbul! Opening Conference:
Adaptive strategies for office spaces in the UK climate
International Conference Passive and Low Energy Cooling 631 Adaptive strategies for office spaces in the UK climate I. Gallou Environment & Energy Studies Programme, Architectural Association Graduate
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries
Energy Audit Consulting Service and Engineering Industry and Trade Limited Company
Energy Audit Consulting Service and Engineering Industry and Trade Limited Company Certified Building and Industrial Energy Manager Training Energy Management System Installation, Implementation, Consulting
EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010
EFA PSBP Natural Ventilation Strategy Introduction The Baseline Designs Project will provide scheme design details for a number of Primary and Secondary School Exemplars. For the purposes of setting a
Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues
Design Guide Retrofitting Options For HVAC Systems In Live Performance Venues Heating, ventilation and air conditioning (HVAC) systems are major energy consumers in live performance venues. For this reason,
Air Conditioning, Comfort and Energy in India s Commercial Building Sector
Air Conditioning, Comfort and Energy in India s Commercial Building Sector THINK.CHANGE.DO Leena Thomas Richard dedear Rajan Rawal Ashok Lall PC Thomas University of Technology, Sydney Sydney University
International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS
International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES
LG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
HEATING, VENTILATION & AIR CONDITIONING
HEATING, VENTILATION & AIR CONDITIONING as part of the Energy Efficiency Information Grants Program Heating and cooling can account for approximately 23 % of energy use in pubs and hotels 1. Reducing heating
Integrated Solar Radiant Systems
Integrated Solar Radiant Systems William Shady PE President Topics Radiant heating Indoor air quality Radiant Cooling Project Photos Questions and answers The goal for our clients Healthy Comfort Why Radiant
Mechanical and Natural Ventilation
BBSE3006: Air Conditioning and Refrigeration II http://www.hku.hk/bse/bbse3006/ Mechanical and Natural Ventilation Dr. Sam C. M. Hui Department of Mechanical Engineering The University of Hong Kong E-mail:
Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres
What factors determine the energy efficiency of a data centre? Where is the energy used? Local Climate Data Hall Temperatures Chiller / DX Energy Condenser / Dry Cooler / Cooling Tower Energy Pump Energy
Exemplary Retrofitting of an Old School in Stuttgart - EROS -
Exemplary Retrofitting of an Old School in Stuttgart - EROS - City of Stuttgart, Summary The objective of the project was to demonstrate the potentials of a retrofitting process for a typical school in
Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment
Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment The heating, ventilation and cooling loads of typical commercial office space can range
Condensing Boiler Efficiency
Condensing Boiler Efficiency Date: July 17, 2012 PRES E NT ED BY DO N L E O NA RDI LE O N A RD I I NC. HV AC T RAI N I N G & C ON SU LT IN G Concepts 1 The current state of evolution in boiler design 2
The Reunion experience
Barcelona Workshop Experience on Net Zero Energy Buildings October 3rd 2012 1 The challenge of designing Net Zero Energy Buildings in Tropical Climates The Reunion experience Prof. François GARDE, PhD,
HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY
HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY Benson Kwong, CVS, PE, CEM, LEED AP, CCE envergie consulting, LLC Biography Benson Kwong is an independent consultant providing
SAP 2012 IN A NUTSHELL
SAP 2012 IN A NUTSHELL The consultation version of the SAP 2012 methodology was published by the Department of Energy and Climate Change (DECC) on January 4th 2012. This article from Dyfrig Hughes of National
Holistic Approach in Delivering Government Buildings The Low Carbon Concept
International Conference on Planning for Low Carbon Cities 22 May 2009 Holistic Approach in Delivering Government Buildings The Low Carbon Concept Ir. HO Sai-king, Assistant Director (Building Services),
How To Become A Bus Driver
Hüseyin Günhan ÖZCAN Office Tel: 0 (232) 411 5000 5687 Cell Phone: 0 (533) 399 99 49 Adress: Yaşar University, Selçuk Yaşar Campus, Energy Systems Engineering Department Room No: U 217 DATE OF BIRTH: 03.21.1985
2 STEPS TO CONDUCTING YOUR HVAC ASSESSMENT
Presentation Synopsis Heating, Ventilating and Air Conditioning Building Condition Assessment Vancouver, B.C. Prepared for: EPIC Prepared by: Douglas Spratt, P.Eng Douglas Spratt & Associates Ltd. www.dspratt-associates.com
Residential HVAC System Sizing
Residential HVAC System Sizing William P. Goss University of Massachusetts, Amherst, Massachusetts, USA Corresponding email: [email protected] SUMMARY Heating, ventilating and air-conditioning (HVAC)
Building Energy Systems. - HVAC: Heating, Distribution -
* Some of the images used in these slides are taken from the internet for instructional purposes only Building Energy Systems - HVAC: Heating, Distribution - Bryan Eisenhower Associate Director Center
AIR CONDITIONING - ENERGY CONSUMPTION AND ENVIRONMENTAL QUALITY
CONTENTS AIR CONDITIONING - ENERGY CONSUMPTION AND ENVIRONMENTAL QUALITY Air Conditioning - Energy Consumption and Environmental Quality - Volume 1 No. of Pages: 400 ISBN: 978-1-84826-169-3 (ebook) ISBN:
Green BIM/ Early BIM/
Green BIM/ Early BIM/ Agenda/ Introduction to Sustainability Process Environmental Analysis Tools Environmental Analysis Relation to LOD Conclusion Disclaimer/ This seminar is looking at Building Performance
HVAC Systems: Overview
HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct
Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now
Fact Sheet #6 Air Conditioning In this fact sheet you will discover: The opportunity for energy efficiency How air conditioning works Low cost actions to reduce energy usage now Investments to reduce costs
Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro
Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro Dept. Building Environment Science &Technologies Politecnico di Milano Italy Research funded
RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary
RULES FOR THE SETTING UP OF SUSTAINABLE BRANCHES Summary January 2013 TABLE OF CONTENTS INTRODUCTION... 3 GENERAL RECOMMENDATIONS... 3 Communication with customers in the field of environmental sustainability...
Lesson 36 Selection Of Air Conditioning Systems
Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section
VENTILATIVE COOLING EBC ANNEX 62 PER HEISELBERG DEPARTMENT OF CIVIL ENGINEERING
VENTILATIVE COOLING EBC ANNEX 62 PER HEISELBERG DEFINITION OF VENTILATIVE COOLING VENTILATIVE COOLING IS APPLICATION (DISTRIBUTION IN TIME AND SPACE) OF VENTILATION AIR FLOW TO REDUCE COOLING LOADS IN
Energy Efficient HVAC-system and Building Design
Energy Efficient HVAC-system and Building Design Maija Virta 1, Harri Itkonen 1, Panu Mustakallio 1, Risto Kosonen 1 1 Halton Oy, Finland Corresponding email: [email protected] SUMMARY This paper
Green House, Hungary
Further information Skanska AB www.skanska.com Contact Noel Morrin, SVP Sustainability & Green Support [email protected] Green House, Hungary Case Study 109 Aspects of Sustainability This project
ASYA KATILIM BANKASI A.Ş LIST OF HAVING ACCESS TO INTERNAL INFORMATION
1 Mehmet Ali İSLAMOĞLU Chairman of the Board of Directors 03.02.2015 2 Aydın GÜNDOĞDU Board Member - President&CEO 03.02.2015 3 Mehmet Ali GÖKÇE Board Member 03.02.2015 4 Bedri SAYIN Board Member 03.02.2015
SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP
research journal 2013 / VOL 05.01 www.perkinswill.com SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP ARCHITECTURE AND ENGINEERING OF SUSTAINABLE BUILDINGS Current Trends in Low-Energy HVAC Design
Priority School Building Programme
UPDATE Includes June 2013 changes to FOS Priority School Building Programme Making sense of the new Priority School Output Specification from the Education Funding Agency. How is the output specification
CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION
CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION 3.1 Purpose of Thermal Load Estimation 3.2 Heating Load versus Cooling Load 3.3 Critical Conditions for Design 3.4 Manual versus Computer Calculations 3.5 Heating
FIRST RADIANT COOLED COMMERCIAL BUILDING IN INDIA CRITICAL ANALYSIS OF ENERGY, COMFORT AND COST
FIRST RADIANT COOLED COMMERCIAL BUILDING IN INDIA CRITICAL ANALYSIS OF ENERGY, COMFORT AND COST Guruprakash Sastry, Senior Manager Green Initiatives Infosys Limited, Bangalore, INDIA ABSTRACT Radiation
High Performance School Buildings Resource and Strategy Guide
High Performance School Buildings Resource and Strategy Guide Published by: Sustainable Buildings Industry Council With support from: California Energy Commission National Concrete Masonry Association
Country University Faculty / Institute Area of Study Degree. Institution / Organization Country City Section / Unit Task Type.
BIOGRAPHY Ferhat ERÖZ Identity Number / Passport No: 43048379424 Year of Birth: 28/11/1966 Mailing Address : Phone : +90 555 219 5663 Fax : E - mail: EDUCATION INFORMATION ÇİĞDEM MAH. 1578 SOK. ARMONİ
White Paper Nest Learning Thermostat Efficiency Simulation for France. Nest Labs September 2014
White Paper Nest Learning Thermostat Efficiency Simulation for France Nest Labs September 2014 Introduction This white paper gives an overview of potential energy savings using the Nest Learning Thermostat
Information paper 20. Prepared by: David Clark. book:
Information paper 20 Ventilation rates in offices and natural mechanical Prepared by: David Clark A paper referenced in the book: Cundall Johnston & Partners LLP. 2013 Issue 1.0: 29 July 2013 This information
HOW AN ENERGY EFFICIENT HOME CAN HELP THE ENVIRONMENT
HOW AN ENERGY EFFICIENT HOME CAN HELP THE ENVIRONMENT During the last century, concern about the environment increased, as issues such as global warming and the Greenhouse Effect convinced us that the
Eurovent Certification
Eurovent Certification Performance Testing and Certification Dedicated Outdoor Air Systems AHU s & Cooling Towers REHVA Seminar ACREX 7 th March 2013 Ian Butler ECC Audit Manager & Key Speaker 2/30 First
ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM
ENERGY SAVING STUDY IN A HOTEL HVAC SYSTEM J.S. Hu, Philip C.W. Kwong, and Christopher Y.H. Chao Department of Mechanical Engineering, The Hong Kong University of Science and Technology Clear Water Bay,
ENERGY SAVING WINDOW FILMS S LAR CONTROL
ENERGY SAVING WINDOW FILMS S LAR CONTROL Overview Managing Solar Heat Gain - Solar Control Window Film With an ever increasing need to achieve outstanding energy efficiency within buildings without compromising
Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:
PASSIVE Solar Design Solar Homes Catch the Sun Are you planning a new house? Discover how you can apply solar architecture principles to: keep your heating bills to a minimum enjoy the comfort of a warm
Building Integrated Combined Solar Thermal and Electric Generation Demonstration Project at Concordia University
Building Integrated Combined Solar Thermal and Electric Generation Demonstration Project at Concordia University Summary An innovative solar energy installation has been installed at Concordia University
Outline. Thermal storage for low carbon buildings. Effect of global warming on design summer year. Environment impacts of buildings
http://www.brighton.ac.uk/csbe Thermal storage for low carbon buildings Kenneth Ip Centre for Sustainability of the Built Environment Outline Background Basic principles of thermal storage in buildings
Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses
Passiv Haus Institut Passivhaus Dienstleistung GmbH Dr. Wolfgang Feist Rheinstr. 44/46 Rheinstr. 44/46 D-64283 Darmstadt D-64283 Darmstadt www.passiv.de www.passivhaus-info.de Certification as "Quality
HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget
A PRIMER Educational HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget Contents: Introduction: The best HVAC system is durable, reliable
Greenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings
Greenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings J A NUARY 2015 INTRODUCTION This Research Report explores best practices and approaches for reducing greenhouse gas (GHG)
A Roof Integrated Solar Heating System Without Storage
M. and W. Saman Sustainable Energy Centre University of South Australia Mawson Lakes Boulevard, Mawson Lakes, SA 5095, Australia E-mail: [email protected] Abstract A prototype of a roof integrated
Software Development for Cooling Load Estimation by CLTD Method
IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) ISSN: 2278-1684Volume 3, Issue 6 (Nov. - Dec. 2012), PP 01-06 Software Development for Cooling Load Estimation by CLTD Method Tousif Ahmed Department
A NEW DESICCANT EVAPORATIVE COOLING CYCLE FOR SOLAR AIR CONDITIONING AND HOT WATER HEATING
A NEW DESICCANT EVAPORATIVE COOLING CYCLE FOR SOLAR AIR CONDITIONING AND HOT WATER HEATING John Archibald American Solar Roofing Company 8703 Chippendale Court Annandale, Va. 22003 e-mail: [email protected]
A DISTANT-LEARNING TRAINING MODULE ON ENERGY EFFICIENT INTEGRATED BUILDING DESIGN IN URBAN ENVIRONMENT
A DISTANT-LEARNING TRAINING MODULE ON ENERGY EFFICIENT INTEGRATED BUILDING DESIGN IN URBAN ENVIRONMENT V.Geros 1, M.Santamouris 1, S. Amourgis 2, S. Medved 3, E. Milford 4 and K. Steemers 5 1. Group Building
Adapting to Change: New Thinking on Comfort Natural ventilation in UK schools: design options for passive cooling Steven Firth* and Malcolm Cook
Proceedings of Conference: Adapting to Change: New Thinking on Comfort Cumberland Lodge, Windsor, UK, 9-11 April 2010. London: Network for Comfort and Energy Use in Buildings, http://nceub.org.uk Natural
Heat pumps: better by nature
Heat pumps: better by nature For office buildings, hospitals, swimming pools, Heat, more than 80% of our energy consumption The burning of fossil fuels to meet our energy demand is resulting in the emission
Small-Scale Solar Heating and Cooling Systems
Contact Austria: AEE INTEC (www.aee-intec.at) France: Tecsol (www.tecsol.fr) Germany: Fraunhofer ISE (www.ise.fraunhofer.de) Greece: CRES (www.cres.gr) Italy: EURAC (www.eurac.edu) University of Bergamo
A heat pump system with a latent heat storage utilizing seawater installed in an aquarium
Energy and Buildings xxx (2005) xxx xxx www.elsevier.com/locate/enbuild A heat pump system with a latent heat storage utilizing seawater installed in an aquarium Satoru Okamoto * Department of Mathematics
UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01
GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per
Energy savings in the residential area are essential in
Overheating and insufficient heating problems in low energy houses up to now call for improvements in future Requirements for improved energy performance have shifted major focus on energy calculations
Context and Items for Discussion
ENGS 44 SUSTAINABLE DESIGN Context and Items for Discussion Benoit Cushman-Roisin 28 March 2016 We have come to realize that our ways of life are Therefore, If we want things to stay as they are, things
CHAPTER 8 HVAC (Heating, Ventilation, and Air-Conditioning)
CHAPTER 8 HVAC (Heating, Ventilation, and Air-Conditioning) Objectives Survey current HVAC system(s), operating procedures, and maintenance schedule. Analyze results of energy audit for HVAC system(s)
Subtropical Cities September 2006. Design for Energy Efficiency in Commercial Buildings in Queensland
Subtropical Cities September 2006 Design for Energy Efficiency in Commercial Buildings in Queensland Contents Typical Building Constraints & Requirements Understanding Energy Consumption in Buildings HVAC
ALONE. small scale solar cooling device Project No TREN FP7EN 218952. Project No TREN/FP7EN/218952 ALONE. small scale solar cooling device
Project No TREN/FP7EN/218952 ALONE small scale solar cooling device Collaborative Project Small or Medium-scale Focused Research Project DELIVERABLE D5.2 Start date of the project: October 2008, Duration:
PV THERMAL SYSTEMS - CAPTURING THE UNTAPPED ENERGY
PV THERMAL SYSTEMS - CAPTURING THE UNTAPPED ENERGY John Hollick Conserval Engineering Inc. 200 Wildcat Road Toronto Ontario [email protected] ABSTRACT PV modules generate electricity, but the electrical
Energy efficiency building standards in Japan
www.asiabusinesscouncil.org Energy efficiency building standards in Japan Japan s regulation of building energy efficiency falls under the Energy Conservation Law that was first adopted in 1979. Subsequently
Federation of European Heating, Ventilation and Air-conditioning Associations
Federation of European Heating, Ventilation and Air-conditioning Associations Address: Rue Washington 40 1050 Brussels Belgium www.rehva.eu [email protected] Tel: +32 2 514 11 71 Fax: +32 2 512 90 62 REHVA
The Business Case Annual fuel cost savings of 26% worth more than 28,000 Annual fuel savings of 1.3million kwh Annual CO2 savings of over 245 tonnes
North Lanarkshire Council The Business Case Annual fuel cost savings of 26% worth more than 28,000 The Sir Matt Busby Sports Complex is an important local facility for the people of Bellshill, North Lanarkshire.
Roche Basel/Kaiseraugst
2020 Roche Basel/Kaiseraugst 1 Contents 5 Introduction 6 Energy Vision 7 Energy Objectives 10 Implementing our Energy Objectives 11 Reduce energy consumption 14 Sustainable energy sources 16 Innovative
ENERGY EFFICIENT WINDOWS & DOORS A GUIDE TO THERMAL PERFORMANCE. www.rehau.co.uk. Building Solutions Automotive Industry
ENERGY EFFICIENT WINDOWS & DOORS A GUIDE TO THERMAL PERFORMANCE www.rehau.co.uk Building Solutions Automotive Industry INTRODUCTION IMPROVING THE ENERGY EFFICIENCY OF WINDOWS AND DOORS Background Environmental
Green Architecture and Construction
Green Architecture and Construction Prof. Dr. Soontorn Boonyatikarn Center of Excellence Building and Environmental Technology, Department of Architecture, School of Architecture, Chulalongkorn University,
School in Schwanenstadt, Austria
School in Schwanenstadt, Austria 1. INTRODUCTION PROJECT SUMMARY - building period 1960s - numerous expansions SPECIAL FEATURES - Renovation to meet Passive House Standard - decentralized ventilation system
Course Curriculum for Master Degree in Architecture
Course Curriculum for Master Degree in Architecture The Master Degree in Architecture is awarded by the Faculty of Graduate Studies at Jordan University of Science and Technology (JUST) upon the fulfillment
Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems
Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems If you're a designer or a BCA, this guidance on the energy efficiency of HVAC systems in commercial buildings may
HVAC Processes. Lecture 7
HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump
TÜRKİYE 2023 ULUSLARARASI NÜKLEER TEKNOLOJİ TRANSFERİ KONGRESİ
PROGRAMME (DRAFT) Turkish Strategic Vision 2023 Strategic Leading Sectors TÜRKEY 2023 INTERNATIONAL NUCLEAR TECHNOLOGY CONGRESS (21-22 September 2012, Istanbul, TURKEY) 1 st Day September 21, 2012 08.30-09.00
How To Design A Room Air Conditioning System
Comparison of HVAC Technology in Buildings Conventional HVAC Technology Bauer Optimising Technology The Differences Room environment (Occupant Comfort) Energy Consumption Architecture Air flows in a room
Prof. Dr. İsmet Vildan ALPTEKİN Department of Landscape Architecture [email protected]
Prof. Dr. İsmet Vildan ALPTEKİN Department of Landscape Architecture [email protected] Prof. Dr. Ismet Vildan Alptekin, completed his undergraduate and graduate studies in Ankara University
THMEDITERRANEAN RHEUMATOLOGY SYMPOSIUM & MEDITERRENEAN RHEUMATOLOGY EULAR BASIC ULTRASOUND COURSE SYMPOSIUM ANTALYA, TURKEY. www.antalyaultrasound.
THMEDITERRANEAN RHEUMATOLOGY & EULAR BASIC ULTRASOUND COURSE TIP FAKÜLTESİ April 22-26, 2015 Cornelia Deluxe Hotel ANTALYA, TURKEY www.antalyaultrasound.com Welcome Message Dear Colleagues, It is my great
TÜRKİYE 2023 ULUSLARARASI NÜKLEER TEKNOLOJİ TRANSFERİ KONGRESİ
PROGRAMME (DRAFT) Turkish Strategic Vision 2023 Strategic Leading Sectors TÜRKEY 2023 INTERNATIONAL NUCLEAR TECHNOLOGY CONGRESS (21-22 September 2012, Istanbul, TURKEY) 1 st Day September 21, 2012 08:30-09:00
Solar Thermal Systems
Solar Thermal Systems Design and Applications in the UAE Murat Aydemir Viessmann Middle East FZE General Manager (M.Sc. Mech.Eng., ASHRAE) Dubai Knowledge Village Congress Centre, Dubai 20.4.2009 Viessmann
Opening the Bonnet. Prof Darren Woolf WYSINWYG 1
Opening the Bonnet Prof Darren Woolf WYSINWYG 1 WYSINWYG What You See Is NOT What You Get: Looking inside the Pandora s Box Prof Darren Woolf WYSINWYG 2 WYSIWYG implies a user interface that allows the
Each icon on this map represents the physical location of a station.
ABBOTSFORD SCHOOL DISTRICT: GREEN TOUR TOMORROW S SUSTAINABLE SOLUTIONS TODAY Welcome to the Abbotsford School District: Green Tour. Our goal is to create an interactive learning experience for visitors
Smart Cities. Integrated approach for innovative technologies. 2nd Annual Conference of the ETP on. Budapest, 6th May 2011
Smart Cities Integrated approach for innovative technologies 2nd Annual Conference of the ETP on Renewable Heating and Cooling Budapest, 6th May 2011 Brigitte Bach, AIT Energy Department Low Carbon Economy
Carbon Management Plan
E-2015-02-02 Addendum Carbon Management Plan Date: 14 May 2014 Owners: Approval: K.W.Bullimore & M.Sackett A.Burrell Executive Summary This document sets out the Carbon Management Plan (CMP) for The Open
Draft UCL Heating, Cooling and Ventilation Policy
Draft UCL Heating, Cooling and Ventilation Policy Page 1 of 7 UCL Estates UCL Heating, Cooling & UCL Heating, Cooling and Document Owner UCL Estates Leadership Team is the Owner of this document. Distribution
HVAC Costs. Reducing Building. Building owners are caught between two powerful forces the need to lower energy costs. By Stephen J.
Reducing Building HVAC Costs of site rec By Stephen J. Pargeter Building owners are caught between two powerful forces the need to lower energy costs and the need to meet or exceed outdoor air ventilation
#127 Heating, Ventilation and Air-conditioning (HVAC): System Design and Value Engineering. Leading To
#127 Heating, Ventilation and Air-conditioning (HVAC): System Design and Value Engineering Leading To System Design and Value Engineering in Heating, Ventilation and Air-Conditioning (6-Credit) P. 1 Heating,
HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow
HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation Richard Lord Carrier Fellow HVAC Industry Challenges and Issues Ozone Deletion Global Warming
Completion of the Technology and Innovation Center
November 25, 2015 Completion of the Technology and Innovation Center Aiming for New Value Creation as a Core Base for Technology Development Daikin Industries, Ltd. announces the completion of the Technology
Riga Smart City Concept. Timurs Safiuļins Riga Energy Agency
Riga Smart City Concept Timurs Safiuļins Riga Energy Agency City development pillars Riga long-term development objectives Riga smart city Sustainable energy action plan 2014-2020 SEAP includes an initial
Klosterenga, Oslo, Norway, 1998-2000 page - 1
Klosterenga, Oslo, Norway, 1998-2000 page - 1 Introduction Klosterenga is an urban revitalisation project close to the city centre of Oslo. The 3 apartments were built with a focus on energy saving. Next
SYSTEMS INTEGRATION SYSTEMS INTEGRATION. Air handler uses heat recovery on exhaust air to temper incoming ventilation air Oxbow skylight
100% outside air intake Air handler uses heat recovery on exhaust air to temper incoming ventilation air Oxbow skylight Smoke evacuation Natural convection exhaust Atrium skylight Phase change material