NATIONAL SECURITY INSPECTORATE
|
|
|
- Oliver Dickerson
- 10 years ago
- Views:
Transcription
1 NATIONAL SECURITY INSPECTORATE NSI CODE OF PRACTICE FOR THE DESIGN INSTALLATION AND MAINTENANCE OF CCTV SYSTEMS NCP 104 (ISSUE 2)
2 This Code of Practice is to be read in conjunction with the NSI Regulations relating to approval by NSI and the NSI Criteria for approval. No company shall hold out or claim that it adheres to this Code, save by virtue of holding NSI approval, or having obtained the written permission of NSI. NCP 104 (Issue 2) January 2010 NSI Copyright. No part to be reproduced without permission of NSI
3
4 National Security Inspectorate Code of Practice for the Design, Installation and Maintenance of CCTV Systems LIST OF CONTENTS INTRODUCTION 1. SCOPE 2. REFERENCES 3. DEFINITIONS AND ABBREVIATIONS 4. GENERAL CONSIDERATIONS 5. OPERATIONAL REQUIREMENT 6. SYSTEM OPERATIONAL CRITERIA 7. SYSTEM DESIGN CRITERIA 8. INSTALLATION 9. COMMISSIONING, HANDOVER AND DOCUMENTATION 10. MAINTENANCE APPENDIX 1 CHECKLIST FOR ESTABLISHING PERFORMANCE REQUIREMENTS APPENDIX 2 EFFECTIVE OBSERVED ANGLES OF VIEW FOR A TYPICAL RANGE OF FOCAL LENGTHS ATTACHMENTS 1. COMMISSIONING CHECKLIST FOR CCTV SYSTEMS 2. HANDOVER CHECKLIST FOR CCTV SYSTEMS 3. ACCEPTANCE CERTIFICATE 4. CORRECTIVE MAINTENANCE REPORT 5. PREVENTIVE MAINTENANCE REPORT 2
5 In this document, material (such as guidelines, information, recommendations, advice) that does not form a mandatory requirement of this Code is shown in italics. FOREWORD Closed-circuit television, in its simplest form, is a means of providing images from a television camera for viewing on a monitor via a private transmission system. There is no theoretical limit to the number of cameras and monitors that may be used in a CCTV installation but in practice this will be limited by the efficient combination of control and display equipment with the operator's ability to manage the system. The successful operation of a CCTV system requires the active co-operation of the users in carrying out the recommended procedures. Note 1: Note 2: Note 3: In conjunction with the application of BS EN : 1996, this Code of Practice aims to assist specifiers, installers, users, insurance companies and police in selecting the level of CCTV equipment best suited to a particular application and to provide minimum requirements for the design, installation and maintenance of CCTV systems. This Code of Practice is regarded as PROVISIONAL pending publication of all parts of European Standard EN Attention is drawn to British Standard Code of Practice BS 8418 for remote monitored, detector activated CCTV systems. 1. SCOPE This Code of Practice, together with BS EN : 1996, specifies requirements for the design, installation and maintenance of CCTV systems used in security applications. Typical examples of security applications are perimeter surveillance, access control, safety, and property protection. Examples of events that may be monitored by these applications include hold-up, theft, sabotage, vandalism, hazards and evacuation. CCTV that is used purely for process control falls outside the scope of this Code of Practice. NSI NACOSS Gold and Systems Silver approved companies shall comply with: This Code of Practice (NCP 104) and BS EN : 1996, or BS 8418 and BS EN : This Code of Practice does not recommend the extent or degree of the protection in the security application, nor does it necessarily cover all the requirements for any other surveillance applications. For ease of cross-referencing, this Code of Practice is structured along the lines of BS EN : Refer to BS EN for details of further requirements. 3
6 2. REFERENCES 2.1 Normative References BS EN Alarm systems - CCTV surveillance systems for use in security applications, Part 7. Application guidelines BS EN Specification for degrees of protection provided by enclosures (IP code) Attention is drawn to the Requirements for Electrical Installations, BS 7671, also known as the IEE/IET Wiring Regulations. Attention is drawn to Part P (Approved Document P) of Schedule 1 of the Building Regulations, which relates to legal requirements for electrical installations in dwellings in England and Wales. Further information about Part P can be found at Informative References BIP 0008 BS 5979 BS 7958 BS 8418 BS 8495 BS EN Code of practice for Legal Admissibility and evidential weight of information stored electronically Remote centres receiving signals from fire and security systems Code of practice Closed circuit television (CCTV) Management and operation Code of practice Installation and remote monitoring of detector activated CCTV systems Code of practice Code of practice for digital CCTV recording systems for the purpose of image export to be used as evidence Protection against lightning 3. DEFINITIONS For the purpose of this Code of Practice the definitions given in BS EN : 1996 apply and, in addition, the following definitions apply: 3.1 Environmental housings: Equipment containers and associated accessories, such as heaters, washers and wipers, to meet specified environmental conditions 3.2 Video distribution amplifier: A device which provides multiple outputs from one video signal such that interference with one output will not affect others 3.3 Video motion detector: A detection device generating an alarm condition in response to a change in the signal from one or more closed circuit television cameras 3.4 Video transmission: A generic term given to the transmission of video signals 4. GENERAL CONSIDERATIONS 4.1 Data Protection Act Attention is drawn to the Data Protection Act 1998 (DPA). 4
7 The Information Commissioner s Office (ICO) published a CCTV Code of Practice in 2008 to replace the first version, which was issued in The purpose of the ICO Code of Practice is to give guidance on how CCTV systems can comply with the DPA. To obtain a copy of the Code of Practice go to Note 1: Note 2: Note 3: Note 4: Note 5: Section 3 of the ICO CCTV Code of Practice 2008 includes guidance on when the use of cameras is exempt from the DPA. This replaces previous guidance given by the ICO who should be contacted in cases of doubt. A checklist for users of limited CCTV systems monitoring small retail and business premises is included at Appendix 2 of the ICO CCTV Code of Practice 2008 to assist users in complying with the DPA. NSI approved companies installing CCTV systems should draw their customers attention to the ICO CCTV Code of Practice and should make them aware of the need to notify CCTV systems to the ICO, except where the DPA does not apply. Where necessary, companies should provide written instructions to customers on how to use their CCTV systems in such a way as to ensure that they are operated within their intended scope and purpose. Attention is drawn to British Standard Code of Practice BS 7958 for management and operation of CCTV (see also 7.11 of NCP 104). 4.2 SIA Licensing and use of NSI approved monitoring centres Attention is drawn to the Security Industry Authority s (SIA s) requirements for the licensing of individuals engaged in public space surveillance (CCTV) and in other security related activities (see NSI approved companies installing CCTV systems and entering into contracts with customers to provide CCTV monitoring services should ensure that in relevant circumstances they only use monitoring companies where the individuals providing the CCTV monitoring service hold the appropriate SIA licenses. Similarly, where customers are likely to enter into their own contracts with third-party providers of monitoring services, NSI approved companies should advise customers to ensure that in relevant circumstances they only use monitoring companies where the individuals providing the CCTV monitoring service hold the appropriate SIA licenses. NSI approved companies should use monitoring centres that hold NSI ARC Gold approval for the monitoring of CCTV systems. In the case of CCTV system installations complying with BS 8418, NSI approved companies shall use only monitoring centres that hold NSI ARC Gold approval as Remote Video Response Centres (RVRCs) (or other RVRCs approved by an independent third-party approvals organization acceptable to NSI and complying with ISO 9001, BS 5979 and BS 8418). 4.3 Performance The performance of a CCTV system is primarily dependent upon the available light level. It is important that a thorough evaluation of the scene and the illumination is carried out as part of the system design (see 7.8 below). 5
8 The combination of cameras and lenses, signal transmission means, monitors and perimeter lighting should be selected to permit, within the system response time, the detection of an intruder easily on the monitor(s) in, or near to, the detection zone by day and night under all likely weather conditions. Brief guidance to users of digital CCTV systems is given in Home Office Scientific Development Branch (HOSDB) Publication No. 09/05 UK Police Requirements for Digital CCTV Systems (for further details, search the HOSDB website for publications). When deciding how best to record and save video images, the following should be considered as a minimum: a) Number of days of video needed to be retained. b) The required image quality required from the recorded video. c) Number of images (frames) per second required to be recorded. It is important that there should be sufficient image storage capacity to meet the requirements for image quality and retention time. 5. OPERATIONAL REQUIREMENT Refer to Clause 5 of BS EN : Persons without appropriate knowledge and expertise may need to become involved in writing specifications for CCTV security systems and one approach to this is to write an Operational Requirement (detailing what the CCTV system is expected to be able to achieve) for subsequent development into a full technical specification by a suitable qualified person. Attention is drawn to Home Office Scientific Development Branch (HOSDB) Publication No. 55/06, CCTV Operational Requirements Manual (for further details, search the HOSDB website for publications). The company shall enquire as to whether or not the customer (or a person acting for the customer) has prepared an Operational Requirement and/or other documented requirements for the proposed CCTV system. The company shall prepare a System Design Specification (as part of the quotation) for a CCTV system to meet the customer s needs, expectations, and patterns of usage of the premises, taking into account any Operational Requirement and/or other customer documented requirements (see 7.11 below). It is of course permissible for the customer to amend the requirements for the CCTV system during the negotiation of the contract. 6. SYSTEM OPERATIONAL CRITERIA Refer to Clause 6 of BS EN : The system(s) shall be easily controlled and monitored by the operator(s). If more than one operator is to be able to control equipment simultaneously, this shall be allowed for in the system design, taking into account more than one operator controlling the same camera and allowing for one operator to pass control to another. Where remotely controlled cameras return automatically to a pre-programmed view, an operator wishing to observe the same scene on another camera shall be able to switch rapidly between selected pictures. If a method of temporarily over-riding the automatic program is utilised, a warning shall be given to remind the operator to return the system to automatic control. 6
9 7. SYSTEM DESIGN CRITERIA Refer to Clause 7 of BS EN : The importance of a correct and adequate survey for installation is paramount; design has a substantial bearing on the performance and reliability of a CCTV system. The CCTV system(s) specified shall give the required performance under the specified scene illumination(s) and environmental conditions. A checklist is included at Appendix 1 for guidance. 7.1 Surveillance zone determination criteria Attention is drawn to the CCTV Code of Practice published by the Information Commissioner s Office. The installation of a CCTV system may give rise to privacy issues in relation to nearby premises and / or areas falling within the fields of view of cameras. Installers should resolve potential privacy issues with prospective customers through the careful design of systems and the use of privacy zones. Wherever intruder detection is within the area of coverage of CCTV cameras, consideration shall be given to the number of monitors required in relation to the number of detection zones to be monitored, the speed of display of information on monitors in order to capture relevant information, and the means for recording images. 7.2 Criteria for determining the number of cameras and their locations Cameras shall be mounted in serviceable positions, free from obstructions and, where possible, avoiding direct bright light sources within the field of view or shining directly onto the lens. The combined effective fields of view of the cameras in a perimeter security system shall cover the entire detection zone of any associated perimeter intruder detection system. In a perimeter security system, where multiple cameras are used, each camera and its support should be included in the effective field of view of at least one other camera where possible. 7.3 Camera and lens selection criteria A camera and lens shall be compatible and shall be selected to cover the area to be viewed, taking into account any person or object required to be identified. Note: Sub-clause 7.6 of BS EN : 1996 recommends object sizes in relation to the operator task. 7.4 Camera selection The type(s) of camera selected shall be suitable for the application(s). There are many different types of camera available with suitability for different applications. A camera that produces good results during daylight hours may not perform after dusk and a camera suitable for low light level conditions may not work with infrared lighting. Available light level will have a major influence on the choice of camera and it should be noted that the sensitivity of a camera measured under laboratory conditions rarely matches results under natural operating environments. 7
10 Colour cameras respond in a similar manner to the human eye but require significantly higher light levels to provide full video signal compared with monochrome cameras. Monochrome cameras have varying degrees of red and infrared response depending on the imaging device used. Therefore in selecting a camera for a particular application it is necessary to consider the type of light source and the spectral response of the imaging device in addition to the scene reflectance and lens. 7.5 Lens selection The focal length of the lens shall be selected to give the required angle of view. Effective observed angles of view for a typical range of focal lengths are given in Appendix 2. Where lighting conditions dictate, lenses shall be fitted with a remotely controlled, or electronically controlled, iris to respond to changes in ambient lighting and to stabilise the video signal over the working range. A lens shall be selected with particular regard to the likely ambient conditions at the location, including: (a) (b) (c) (d) (e) (f) Available scene illumination Temperature Humidity Dust and airborne particles Contamination Lens filter to suit the lighting environment. 7.6 Recommended object sizes The recommended minimum object sizes are as follows: For identification of the object not less than 120% of screen height For recognition of the object For detection of the object For crowd control not less than 50% of screen height not less than 10% of screen height not less than 5% of screen height Refer to sub-clause 7.6 of BS EN : 1996 for further details. 7.7 Ancillary equipment The environmental conditions under which equipment will be expected to operate shall be taken into account and environmental housings affording appropriate protection shall be specified. Equipment should be installed to manufacturers instructions. Equipment exposed to direct sunlight may require appropriate shielding to avoid the possibility of overheating. To reduce the risk of condensation a heater should be installed within housings installed in external locations. External dome camera housings may require a heater and fan. Where there exists the possibility of penetration by solid objects, dust or water, environmental housings affording appropriate protection shall be specified in accordance with BS EN
11 7.7.1 Camera housings A camera and its supporting hardware shall be securely mounted. The camera mounting bracket or pole and its fixings shall support safely the weight and the windage of the camera and of any associated hardware Pan and tilt units Mechanisms shall be specified to take account of the following: (a) (b) (c) The maximum required pan and tilt rotations and any intermediate preset stops within these. The required rotational speed. The maximum supported load. In the interests of safety, it is recommended that extra-low voltage mechanisms should be specified. A prominent warning notice shall be affixed to moveable camera positioning equipment indicating that sudden movement of the equipment can occur. The following environmental considerations shall be taken into account: (i) (ii) (iii) (iv) Rigidity, taking into account potential wind velocity. Weather conditions, including humidity and the potential for ice formation. Operating temperatures. Dust, airborne particles and other potential types of contamination. The manufacturer's recommendations for installation should be followed. Unless one preset position is used, consideration should be given to the method of movement and to requirements for limit stops or similar safety devices Towers and brackets Before erecting brackets or towers the following environmental considerations shall be taken into account: (a) (b) (c) Rigidity, taking into account potential wind velocity, equipment type and equipment mounting and fixing positions. Electrical interference and the possibility of damage by lightning (see BS EN 62305). Dust, airborne particles and other potential sources of corrosion or contamination. Equipment should be installed according to the manufacturer's instructions. Equipment shall be so installed as to provide appropriate safety and accessibility for maintenance, taking into account any environmental constraints and the security of the installation. 9
12 Where movement of towers is possible, cables shall be carefully selected and installed and their safety and ease of tampering considered. The alignment and mounting of line of sight (e.g. optical and microwave) transmission equipment is often critical and consideration shall be given to the method of alignment and to the rigidity of the mounting; natural movements, such as those experienced by tall buildings, can seriously affect system performance. 7.8 Evaluation of the scene and illumination Refer to sub-clause 7.8 of BS EN : A survey of the site shall be undertaken and an appropriate plan shall be prepared. The survey should identify areas where lighting may need to be adjusted and/or additional lighting may need to be provided. The selection of cameras and lenses suitable for operation under the proposed light levels may then be carried out with certainty. The performance of a CCTV system is primarily dependent upon the available light level. It is important, therefore, that the limits of light levels within which a CCTV installation is intended to function are expressed in units of illumination (e.g. lux). An indication of typical light levels is given in Figure 1 below. By way of general indication only, some other typical light levels are given below. Substantial variation can occur, especially towards lower light levels, according to weather conditions. Typical Light Levels Moonless, overcast night sky Moonless, clear (i.e. starlight) night sky Quarter moonlight on a cloudless night Deep twilight Twilight lux lux 0.01 lux 1 lux 4 lux Well lit main road Stairs/Passages Offices/Retail Store Daylight Full sunlight 10 lux 60 lux 250/500 lux 10,000/25,000 lux 32,000/130,000 lux Light level measurements taken using a light meter should normally not be regarded as giving exactly the same as the lux levels received at cameras. 7.9 Selection of the video transmission system Where utilised in exterior applications, and unless otherwise specified, transmission equipment shall be protected to the requirements of IP 65 of BS EN 60529: The selected transmission method shall have an input and output impedance matching that of the connected equipment. Transmission shall be effective over the required distance taking into account possible signal loss due to cable and environmental effects. 10
13 The manufacturer's recommendations should always be followed Main video transmission systems Refer to sub-clause of BS EN : a) Coaxial cable transmission The cable shall be suitable for video transmission and for the environmental conditions. Unless otherwise specified, the cable screen shall provide at least 90% coverage and the cable size shall allow for the fitting of high frequency video connectors such as the BNC and UHF types. Long cable runs may require the use of video amplification and video equalising equipment and, as the requirements for such equipment are dependent upon both the type of cable and the video equipment used, the manufacturer's recommendations should always be followed. b) Twisted pair cable transmission Existing transmission lines shall be tested to establish that they will perform satisfactorily. Twisted pair cable transmission normally requires video correction controls. These controls should only allow adjustment by means of a special tool or should be covered by a protecting plate. c) Microwave and radio frequency transmission Where applicable, systems shall meet the relevant requirements of the Office of Communications (Ofcom) and any necessary licences shall be obtained. Correct alignment and mounting of transmitting and receiving devices is essential. Particular attention should be given to the method of alignment provided and the rigidity of the mounting. d) Infra-red and laser transmission Some infra-red and laser devices can damage the eye. In such cases suitable warning labels shall be fitted and the necessary precautions specified by the HSE shall be taken. Correct alignment and mounting of transmitting and receiving devices is essential. e) Fibre optic transmission Fibre optic transmission should utilise commonly available types of cable with appropriate fibre optic connections. 11
14 f) Network transmission Equipment used to connect CCTV systems to telecommunications networks shall have relevant (e.g. BABT) approval. The above methods are given as examples and are not intended to prohibit the use of other transmission methods such as Internet Protocol (IP) Selection criteria for video transmission Refer to sub-clause of BS EN : Monitors The resolution of the monitor shall not limit the overall system performance and over-scanning shall not exceed 10%. Consideration shall be given to the environmental conditions in which the monitor will operate. The manufacturer's recommendations should normally be followed with particular regard to: (a) Operating temperature; (b) Humidity; (c) Dust and airborne particles; (d) Background lighting, in particular that falling directly onto the screen. Appropriate access should be provided for servicing Control equipment Control equipment shall be selected so that the system is able to meet the Operational Requirement (see 5 above). Control equipment capability should take account of foreseeable future requirements. Control equipment may be a proprietary computer. The manufacturer's specified environmental conditions shall be provided in respect of: (a) (b) (c) (d) Temperature and humidity; Dust and other forms of air contamination; Vibration; Electrical interference. The following shall be taken into consideration when siting control equipment: (1) Ventilation (2) Access for maintenance (3) User access for archiving etc. (4) Physical security and supervision (5) Convenience for operator use. 12
15 7.10 Control centre configuration Refer to sub-clause 7.10 of BS EN : CCTV control centres (monitoring centres) vary considerably in size and complexity depending upon the surveillance application (e.g. city / town centre scheme, industrial estate, housing estate, large commercial building, small business, dwelling) and the needs of the customer. For example, the control centre may be located at the premises where the CCTV system in installed, or at a location remote from the premises. Monitors should be sited so that their screens are shielded from bright lighting and so that windows or other brightly lit objects are not reflected from the face of the monitor tube. Multiple monitors shall be mounted so that adequate ventilation is available to avoid the possibility of overheating. Contrast, brightness and, if applicable, colour controls shall be readily accessible and provision shall be made for the removal of dust attracted to the face of the picture tube. There shall be minimal change in picture size with change in brightness and highlights in the picture shall not cause defocussing. Colour monitors shall have a fixed black level although in monochrome systems a slight increase in black level for low contrast scenes may be advantageous. Monitors shall be positioned appropriately, considering viewing conditions for scenes including sources of reflection or creating highlights or excessive contrast System design specification The System Design Specification shall provide for a CCTV system meeting the Operational Requirement (see 5 above) and / or other specifications provided by the customer (or a person acting for the customer), except where altered in consultation with, and with the agreement of, the customer. Where an Operational Requirement is not available, as may be the case for less complex CCTV systems, the System Design Specification, drawn up as part of the process of ascertaining the customer s needs, expectations, and patterns of usage of the premises, forms the basis of the agreement between the installing company and the customer as regards the CCTV system to be supplied. The System Design Specification for a CCTV system shall draw the customer s attention to: (i) (ii) (iii) The Data Protection Act (except in clear cases where the DPA does not apply) and the CCTV Code of Practice published by the Information Commissioner s Office. The requirement to provide signs under the Data Protection Act (except where the DPA does not apply). British Standard Code of Practice BS 7958 for the management and operation of CCTV (which is applicable to CCTV used in public spaces and also provides good practice for all other CCTV) and indicate where the document can be obtained (e.g. from British Standards Institution or National Security Inspectorate). The System Design Specification shall include all the main equipment, including power supplies, and components to be supplied and detail the proposed locations. 13
16 The specification shall give details of the: (a) (b) (c) (d) (e) (f) (g) (h) (i) Kind of camera to be used; and Focal length of lens and area of coverage (for example, in terms of the field of view, maximum and minimum range) to be used; and Location of the camera (for example, height above ground); and Intended purpose of surveillance (for example, identification, recognition, detection or monitoring); and Minimum light level limits (e.g. lux) within which each camera / lens combination is intended to operate; and Ancillary lighting (if needed) to achieve the intended light level operation; and Pan, tilt or zoom functions; and Any other automatic and / or remote control functions; and Mounting arrangements. Where zoom lenses are used, the minimum and maximum focal length and zoom ratio should be stated. It may be helpful to give the customer a plan of the site showing intended locations of cameras and their areas of coverage as part of the documentation forming the System Design Specification. Where the field of view of a camera necessarily includes the horizon, consideration should be given to locating the camera such that its field of view is directed towards the North, rather than towards the South, to minimise possible effects of sunlight. The System Design Specification shall include details of the system operational criteria (see 6 above) and, where applicable, the control centre configuration (see 7.10 above). For each detector that is capable of providing inputs to a CCTV system, the system design specification shall give details of the: a) Location of the detector, including height b) Purpose / function of the inputs c) Detector range and coverage System test specification A system test specification shall be agreed and the tests shall be selected to demonstrate, during handover (see 9.3 below) that the CCTV system meets the specifications agreed, including those given in the operational requirement. The test method described in Annex A of BS EN : 1996 (or similar) should be used wherever an objective evaluation is required to confirm that the required performance can be obtained. The use of the test method described in Annex A of BS EN : 1996 (or similar) is a matter for agreement between customer and installer and is not a requirement for every installation. Other test methods are permissible. 14
17 8. INSTALLATION Refer to Clause 8 of BS EN : Planning the installation Power supplies shall be capable of meeting the largest load likely to be placed upon them under normal operating conditions. Where safety and security considerations do not require continued operation of the CCTV system during a mains supply failure, the public mains supply may be the sole supply for the system. Some CCTV systems running from a 230 V mains supply require the equipment to be connected to the same electrical phase. Power supplies shall be located within a secure area, in a position safe from tampering, and shall be ventilated in accordance with manufacturers requirements for safe operation. All equipment housings shall be clearly marked with the operating, or supplied, voltage. The voltage drop in cables shall be considered to ensure that in worst case conditions the voltage drop does not cause the operation of any devices connected by the cables to be impaired. 8.2 Cable installation All wiring and connections shall be installed in accordance with good safety installation practice. Attention is drawn to the Regulations for Electrical Installations, BS 7671, also known as the IEE/IET Wiring Regulations. Extra-low voltage and signalling cable shall not be installed in ducting / trunking which is carrying mains cable, or parallel to mains cables, unless suitably screened, insulated and/or segregated. Wherever possible, extra-low voltage cables shall not be brought into any item of equipment through the same entry point as mains cables. Interconnecting wiring to a camera should, wherever practicable, be concealed. Where this is not practicable, mechanical protection should be used, such as metal conduit, or flexible conduit for moveable cameras. All fixed interconnection cables shall be supported and the installation shall conform to good working practice. Suitable fixing methods include: (a) (b) Conduit: when metal is used, suitable bushes or grommets should be fixed to each end to prevent damage to the cable. Conduit used to carry cable should terminate as close as possible to the unit being connected. PVC or metal trunking: where trunking is used to carry cable it should terminate as close as possible to the unit being connected. 15
18 (c) (d) (e) Insulated clips. Cable ties. Overhead catenary wires with loop holders or plastic buckles. Where this method is utilised the catenary wire should be securely attached to the building. Self-supporting catenary cables may be used provided they are correctly designed. Any plastic or PVC component used as part of the installation of cables shall be suitable for the environment in which it is installed. Cables shall be mechanically protected against accidental damage. In public areas, cables installed below a level of three metres above ground level should normally be mechanically protected. Excessive cable at the end of large runs should be coiled to prevent damage during installation. Manufacturer's recommendations for minimum bend radius of cables should be observed. The jointing and termination of coaxial or fibre optic cables shall always use the correct video or fibre optic connectors or junction boxes. Equipment should be installed to the manufacturer's recommendations and in accordance with good working practice. Cables carrying data and other level signals / voltages shall be of a type and size compatible with the rate of data transfer, anticipated levels of electrical interference and any voltage drop. All cables and cores should incorporate a means for their identification e.g., by colour coding or suitable labelling. Environmental conditions such as dampness, excessive heat, risk of corrosion, mechanical or chemical damage, shall be taken into account in determining the degree of protection required for cable runs. Any cables which are used underground shall be suitable for that purpose and shall have adequate protection from mechanical damage. Underground cables should provide a high level of resistance to dampness, chemical reactions, corrosion and rodents. 8.3 Hardware mounting Sufficient access to equipment shall be provided to enable necessary service and maintenance. 8.4 Documentation Cabling shall be clearly and unobtrusively labelled at the distribution and control panels to facilitate future maintenance and servicing, and a cross-reference chart showing the relationship between cables and devices shall be held by the installing company and a copy given to the customer. 16
19 9. COMMISSIONING, HANDOVER AND DOCUMENTATION 9.1 General Commissioning shall consist of the inspection and testing of the installed system(s) by the installation technician; handover requires the demonstration of the system(s) to the user(s) and the subsequent acceptance of the installation by the customer. 9.2 Commissioning Commissioning shall include visual and functional testing to ensure that: a) The system is installed in strict accordance with the agreed specification and that the standard of workmanship is high, and b) The commissioning requirements of this Code of Practice and BS EN : 1996 are met. This will include testing of the following aspects of the system(s): - All wiring is correctly terminated. - Supply voltage is correct to all appropriate parts of system. Where low voltage cameras are used, the voltage at each camera should be recorded. - Operation of all monitoring, switching, multiplexing and recording equipment is satisfactory, including playback equipment. - Interfaces with alarms (e.g. movement alarms, fences) are satisfactory and triggering of alarms is correct. - Beam interruption detectors are aligned correctly, where used for triggering the CCTV system. - [Text deleted] - All indicator lamps are working. - If a standby power supply is specified, ensuring that the system continues to operate correctly to specification when the mains supply is disconnected. This will also include testing of the following aspects for each camera: - Camera type and lens fitted is correct for each position. - Operation of all automatic and / or remotely controlled camera functions (e.g. pan, tilt, zoom, focus, electronic iris, wiper) is satisfactory. - Correct setting of all pan and / or tilt limits. - Camera movement, and field(s) of view seen through the appropriate monitor(s), is correct and free from obstruction. - Operation of electronic irises and focus is satisfactory under the range of intended light levels (night conditions may be simulated though use of suitable neutral density filters). - Satisfactory operation of supplementary lighting. - Warning labels are in place in respect of possible sudden movement of camera positioning equipment and in respect of any devices that could cause damage to the eye. An example Commissioning Checklist is given as Attachment 1. 17
20 9.3 Handover At handover the installing company shall: (a) (b) Ensure all system documentation is correct (see 9.4 below). Train the designated user(s) in the correct operation and adjustable features of the system; The customer should be requested to make available the designated user(s) to receive training. (c) Provide a system log book to the customer and explain how to record / report events; (d) (e) (f) Demonstrate all aspects of the operation of the system(s) and compliance with the agreed requirements; where required using the test method referred to in Annex A of BS EN : 1996 to confirm that the performance of the installed system is satisfactory for the customer's purposes and recording the result(s) obtained. Consideration shall be given to making a recording of video information obtained during the demonstration for the purpose of creating a benchmark against which to check future system performance. The installer should keep a copy of the video recording, which may be used, for example, as part of the periodic test scheme (see 7.12 of BS EN :1996) and a copy may be given to the customer if so requested. Where an installing company enters into a contract with the customer to provide a monitoring service using another company as sub-contractor, arrangements with the other company shall ensure that the demonstration can be performed and completed. Ensure that the correct documentation is given to the end user to enable the system to be operated; Ensure that the user(s) are aware of the procedure for summoning assistance in the event of system malfunction. An example Handover Checklist is given as Attachment 2. Following handover the customer shall be asked to sign an acceptance document and to enter any confidential information (e.g. passwords which restrict user access to engineer and other reserved functions) required to make the system perform to the agreed specification. An example Acceptance Document is given as Attachment Documentation Upon completion of a CCTV installation there shall be a record for each system making up the installation, which shall include the following information where appropriate: (a) (b) (c) The name and address of the protected site; The name and address of the customer; The location of each control unit and the type and location of each camera and its associated hardware; 18
21 (d) (e) (f) (g) (h) (i) (j) An indication of the camera view(s) defining the protected area(s) and the identification of any specific areas that cannot be successfully or consistently protected by the system; The camera view(s) may be provided in the form of a drawing, a hard copy printout or a video recording. The type and location of power supplies; Details of those cameras that the customer has the facility to manoeuvre or isolate; The type and location of monitors and indicating and / or warning devices; Manufacturer's documentation relating to equipment and its operational settings/controls; Full instructions for the correct use of system, including details of routine testing procedures and any necessary maintenance requirements (see 10); possible sources of interference with the system and equipment with which the system itself will interfere shall be identified. The operation, storage and cycling of recording media such as videocassette tapes and digital audiotape. The make and model number of all items of equipment shall be stated in the system record (or alternatively the installing company s own identifying reference such that using its own records the installing company can identify the make and model number). The system record (i.e. for the as installed system) shall be agreed with the customer and a copy provided to the customer. The customer should be offered drawing(s) of the CCTV installation. Where symbols are used in drawings, a key to these symbols should always be provided to enable customers to understand the content of the drawings. The customer shall be provided with the record of the results of the objective test (see 7.12 above), where this was agreed to be a requirement. All documentation referring to a security system should be kept in a place to which access is restricted to authorised persons. 10. MAINTENANCE For the purposes of this section, the following definitions apply: 10.1 Definitions Preventive Maintenance: Routine servicing of a system, carried out on a scheduled basis Corrective Maintenance: Emergency servicing of a system, or part thereof, carried out in response to the development of a fault CCTV Technician: A person who is trained and competent in the installation, maintenance, servicing and fault-finding of CCTV systems. 19
22 Preventive Maintenance Report: A document that records the preventive maintenance carried out in accordance with this Code of Practice or other applicable technical standard. An example Preventative Maintenance Report Form is given as Attachment Corrective Maintenance Report: A document that details the requirement for normal or emergency corrective maintenance and indicates the corrective action taken, as required by this Code of Practice or other applicable technical standard. An example Corrective Maintenance Report Form is given as Attachment Customer: Any person or organisation utilising the services of an approved company for the maintenance and servicing of a CCTV system. It includes the customer's agent Maintenance Service Agreements 10.3 Staff Where preventive and/or corrective maintenance service is provided, it shall be delivered in accordance with this Code of Practice. Installing companies should be able to offer support to the system for a period of five years from handover date. Every approved company shall have sufficient CCTV technicians to maintain and service all its CCTV maintenance contracts in accordance with this Code of Practice (or other applicable technical standards including manufacturers instructions) Corrective Maintenance The emergency service (corrective maintenance) facility shall be so located and organised that, under normal circumstances, the approved company s CCTV technician attends the premises within the time agreed in the contract with the customer A reliable system of communication between the controlling office, the customer and all CCTV technicians shall be maintained at all times There shall be one or more stand-by CCTV technicians. If there is only one CCTV technician on call-out there shall be a support facility to meet the requirements of paragraph above CCTV technicians and other duty engineering staff shall be available and shall keep in regular and frequent contact with their operational base The CCTV technician shall determine the cause of any fault and then carry out one or more of the following: (a) (b) (c) Repair and leave the CCTV system fully operational. Temporarily repair the CCTV system subject to approval of the customer. With the customer's approval, disconnect part of the system and obtain the customer s signature. 20
23 (d) In the case of a fault in a video transmission system, to confirm the condition and change the system to alternative transmission (if installed) and obtain the customer's signature. If the fault on the CCTV system cannot be located or positively confirmed, the CCTV technician shall contact service control for instruction A report of all action taken shall be made on the corrective maintenance report and the customer's signature obtained. A copy is to be made available to the customer. (An example Corrective Maintenance Report Form is given as Attachment 4) Any parts of the CCTV system disconnected or temporarily repaired shall be recorded, obtaining the customer's signature as authority, and must be reported for further action. The approved company shall ensure that action is taken as soon as possible and, in any case, in accordance with the contract for maintenance Preventive Maintenance Where a maintenance service agreement has been entered into, it is essential that approved companies have the capability to operate a planned programme of preventive maintenance visits. It is recommended that a preventive maintenance visit should be made during or before the twelfth calendar month following the month of handover. Thereafter, preventive maintenance visits (if agreed) shall be made at the frequency agreed in the contract with the customer When carrying out a preventive maintenance visit the CCTV technician shall first establish with the customer whether there have been any problems with the CCTV system since the last preceding preventive maintenance visit. The CCTV technician shall examine the system documentation, or that kept by the customer, to see whether there have been any service calls or incidents since the last preceding routine visit. Where possible, the CCTV technician shall also enquire whether there has been, or is likely to be, a change of use of the premises, a change of working procedures, or a change of tenure. The CCTV technician shall ensure that the customer (or the customer s representative) is still fully conversant with the operation of the CCTV system The CCTV system shall then be visually inspected, checking the following items: (a) (b) (c) The number and type of cameras, including lenses, are in accordance with that stated in the specification and any amendment. Draw the customer s attention to any deviations found. Indicator lamps are working correctly. Replace faulty indicator lamps as required. Warning labels are still in place. Replace missing labels as required. 21
24 (d) All cables and conduit (including those that are flexible) are properly supported, undamaged and showing no signs of wear. Lower towers where necessary in order to inspect cables. (e) Ensure sound physical fixings of all equipment including examinations for loosening or corrosion of supports and fixings, including towers and brackets. Lubricate tower mechanisms, where applicable, in accordance with manufacturers instructions and repair or replace brackets as necessary. (f) All glands and seals on external equipment. Repair or replace glands and seals as necessary to maintain the agreed specification The CCTV system shall then be functionally inspected, checking the following items: (i) (ii) (iii) (iv) (v) (vi) The picture quality of each camera and correct monitor selection. Look for signs of condensation on windows of camera housings and limiting of picture highlights. Where necessary, remove covers and housings and clean interiors. All automatic and remote control camera functions comply with specification (e.g. pan, tilt, zoom, electronic iris, focus, wipers, washers, heaters) and that camera movement and fields of view are free from obstruction. Operation of all monitoring, switching, multiplexing and recording equipment (including time and date generators) is satisfactory. All equipment, in particular video recording equipment, should be maintained and serviced in accordance with manufacturers recommendations and instructions. Function of all interfaces with alarms is satisfactory including correct triggering of alarms. Operation of supplementary lighting is satisfactory. Lamps should be replaced at frequencies recommended by manufacturers so as to minimise the possibility of failure between preventive maintenance visits. As the life of a particular lamp cannot be known with certainty, avoidance of such failure cannot be guaranteed. Items requiring attention shall be rectified and / or reported as necessary, recording all such work on the preventive maintenance report. (An example Preventive Maintenance Report Form is given as Attachment 5) Check that the performance of the system(s) continues to meet the agreed Specification / Operational Requirement according to the periodic test scheme agreed with the customer. 22
25 APPENDIX 1 CHECKLIST FOR ESTABLISHING PERFORMANCE 1.1 Operational Criteria Procedures System response 1.2 Surveillance Fixed, movable or moving view Number and location of cameras Coverage Complexity (cost implications) 1.3 Camera and Lens Selection Compatibility Suitability Camera type e.g. standard / low-light, monochrome / colour Required angles of view 1.4 Recommended Object Sizes Identification Recognition Detection e.g. alarm event coverage Monitoring e.g. general surveillance. 1.5 Camera mounting system Pan / tilt / zoom Poles / towers / wall brackets Aesthetics Planning regulations Camera housing 1.6 Scene and Illumination Levels of illumination Supplementary lighting Visible or discreet Local or general Lighting efficiency e.g. bulb life, lumens / watt Uniformity Colour rendering (or wavelength) 1.7 Video transmission Coaxial cable Twisted pair cable Fibre-optic cable Microwave Free-space optical Slow-scan 1.8 Telemetry Hard-wired parallel Coaxial cable Separate twisted-pair Integration with the video transmission medium Compatibility between systems Facilities to be provided System expansion capability Preset positioning Priority assignment 23
26 APPENDIX 1 CHECKLIST FOR ESTABLISHING PERFORMANCE (CONTINUED) 1.9 Monitors Number required to provide the required level of surveillance Monitor size and operational requirements Monitor resolution (see Appendix 2) Positioning for minimization of on-screen reflections or use of mesh filters Acceptable video signal level at monitor input Radiation output Facilities Acceptable picture quality e.g. for extended or 24 hr surveillance 1.10 Control and Recording Equipment Type of recording e.g. time-lapse or real-time Number of VCRs and/or DVRs required for general surveillance or alarm-only Multiplexers Time-lapse interval Alarm handling Tape and/or digital image management Frame rates and storage capacity 1.11 Play-back Location, in relation to system operator Tape format compatibility Requirement for specific play-back equipment e.g. additional multiplexer Maintenance considerations e.g. head life and tape quality 1.12 Switching Auto-sequencer or switcher Matrix system Spare outputs / test points Assignment of priorities 1.13 Video channel performance Bandwidth Cross-talk Isolation Signal / noise ratio 1.14 Expansion capabilities Further camera inputs Further monitor / VCR outputs Further operator positions Integration with alarm detection and monitoring systems Integration with camera telemetry system 1.15 Ancillary equipment Video buffer, compensation amplifiers Video distribution amplifiers Signal monitoring devices Solid state and magnetic disc storage systems Video printers Video motion detectors 1.16 Telecommunications networks Image quality System reliability Protection of data Quantity and speed of data transmission 24
27 APPENDIX 2 EFFECTIVE OBSERVED ANGLES OF VIEW FOR A TYPICAL RANGE OF FOCAL LENGTHS Figures given in the table below assume 10% monitor overscan. Figures given in the table below are approximate and will vary according to the source of manufacture. Table: Observed angles of view Focal length of lens ½" Image sensor (Image 6.4 mm x 4.8 mm) ⅓" Image sensor (Image 4.8 mm x 3.6 mm) ¼" Image sensor (Image 3.6 mm x 2.7 mm) mm Horizontal Vertical Horizontal Vertical Horizontal Vertical º 62.4º 51.7º 37.8º 27.3º 26.2º 20.6º 13.3º 11.9º 6.7º 4.4º 3.3º 2.1º 1.7º 63.9º 48.9º 40.0º 28.8º 20.6º 19.8º 15.5º 10.0º 8.9º 5.0º 3.3º 2.5º 1.6º 1.3º 63.9º 48.9º 40.0º 28.8.º 20.6º 19.8º 15.5º 10.0º 8.9º 5.0º 3.3º 2.5º 1.6º 1.3º 50.1º 37.6º 30.5º 21.8º 15.5º 14.9º 11.7º 7.5º 6.7º 3.7º 2.5º 1.9º 1.2º 0.9º 50.1º 37.6º 30.5º 21.8º 15.5º 14.9º 11.7º 7.5º 6.7º 3.7º 2.5º 1.9º 1.2º 0.9º 38.6º 28.7º 23.1º 16.4º 11.7º 11.2º 8.8º 5.6º 5.0º 2.8º 1.9º 1.4º 0.9º 0.7º NOTE: Lenses designed for a particular image size may also be used with sensors of a smaller image size. This will have the effect of reducing the angle of view. 25
28 COMMISSIONING CHECKLIST FOR CCTV SYSTEMS Company Name:... Company Address: Telephone No:.... Customer:... Address:... Job No:... Date: Tick When Checked Remarks 1. Check that the installation is in strict accordance with the agreed specification and is to acceptable workmanship. 2. Check that the requirements of NCP 104 and BS EN :1996 and all other relevant requirements are met. 3. Check all wiring is correctly terminated. 4. Check supply voltage is correct to all appropriate parts of system. 5. Check that operation of all monitoring, switching, multiplexing and recording equipment is satisfactory. 6. Check interfaces with alarms (e.g. movement alarms, fences) and correct triggering of alarms. 7. Check beam interruption detectors for correct alignment if used for triggering the CCTV system. 8. Check that appropriate notices have been provided. 9. Check that all indicator lamps are working. 10. Check that system continues to operate correctly to specification when mains supply is disconnected (if standby power supply specified). FOR EACH CAMERA (1 to 8) TICK WHEN CHECKED A. Check camera type and lens fitted is correct for each position. B. Check correct operation of all automatic and / or remotely controlled camera functions (e.g. pan, tilt, zoom, focus, electronic iris, wiper). C. Check correct setting of all pan and/or tilt limits. D. Check that camera movement and field(s) of view seen through the appropriate monitor(s) is correct and free from obstruction. E. Check operation of electronic irises and focus is satisfactory under the range of intended light levels. F. Check satisfactory operation of supplementary lighting. G. Check that warning labels are in place in respect of possible sudden movement of camera positioning equipment. Outstanding work required if any of the above is not ticked: CCTV Technician s Signature:... Date:. NCP 104 Attachment 1 26
29 HANDOVER CHECKLIST FOR CCTV SYSTEMS Company Name:... Company Address: Telephone No:... Customer:.... Address:.... Job No:... Date:... Tick When Checked Remarks 1. All system documentation is correct. 2. Designated user(s) have been trained in the correct operation and adjustable features of the system. 3. A system log book has been provided to the customer and an explanation has been given on how to record / report events. 4. All aspects of the operation of the system(s) and compliance with the agreed requirements have been demonstrated to the customer in accordance with the agreed system test specification. 5. A recording of the information obtained during the demonstration has been made. 6. Correct documentation has been given to the end user to enable the system to be correctly operated. 7. User(s) have been made aware of the procedure for summoning assistance in the event of system malfunction. 8. Check that all documentation in accordance with NCP 104 is correct. (It is Recognised that some check under this heading may be subsequent). 9. Record the number of the Certificate issued in accordance with the Council s Rules. 10. Obtain client s signature acknowledging acceptance of the system(s) - see Attachment 3 of this Code of Practice. 11. Check that all surplus materials and equipment are cleared from the site and that premises are left clean and tidy. Outstanding work required if any of the above is negative: CCTV Technician s Signature:... Date:.. NCP 104 Attachment 2 27
30 ACCEPTANCE CERTIFICATE Customer:... Ref: Address: System Record Reference:... Dated: I confirm that the CCTV system has been installed to my satisfaction and that the premises have been left in a tidy condition and that I have received: 1. training in the operation and adjustable features of the CCTV system 2. a record book (system log book) for the CCTV system 3. a demonstration showing compliance of the CCTV system with the requirements using the agreed system test specification 4. full and comprehensive written operating instructions for the CCTV system 5. details of the procedure for summoning assistance in the event of system malfunction. Customer s Signature:... Signature on behalf of Installing Company:... Date:... NCP 104 Attachment 3 28
31 Company Name: Address: Telephone No: Fax No: CORRECTIVE MAINTENANCE REPORT Customer: Address: Tel: Fax: Date:... Contract No: Specification No:... Account No: Location of fault: REPORTED FAULT:... Camera Recording Equipment... Monitor PTZ Equipment... Detector Control Equipment... Illumination Transmission Fail... Other (Specify) 1. Customer related REASON FOR CALL-OUT A. Operator B. Unauthorised adjustment C. Unauthorised removal of equipment 2. Company related A. Design B. Installation C. Maintenance D. Line Fault E. Power Fail F. Non-electric (e.g. mounting) 3. Other Please state REPORT/ACTION TAKEN: Further action required The system was left in full working order, apart from the items and/or disconnections listed below: Technician s signature:..... Customer s signature: Office Use: Time Initials NCP 104 Attachment 4 29
32 PREVENTIVE MAINTENANCE REPORT Customer:... Address: Item Check 1. Check the number and type of cameras, including lenses, are in accordance with the specification and any amendment. 2. Check indicator lamps are working correctly. 3. Check warning labels are still in place. 4. Check all cables and conduit are properly supported, undamaged and showing no signs of wear. 5. Check for sound physical fixings of all equipment including loosening or corrosion of supports and fixings including towers and brackets. 6. Check all glands and seals on external equipment. 7. Check the picture quality of each camera and correct monitor selection. 8. Covers and housings have been removed and interiors cleaned where necessary. 9. Check all automatic and remote control camera functions are satisfactory and that camera movement and fields of view are free from obstruction. 10. Operation of all monitoring, switching, multiplexing and recording equipment (including time and date generators) is satisfactory. 11. Function of all interfaces with alarms is satisfactory including correct triggering of alarms. 12. Operation of supplementary lighting is satisfactory. 13. Check that the performance of the system(s) continues to meet the agreed specification / operational requirement according to the periodic test scheme agreed with the customer. The system has been left in full working order apart from the items listed below: Tick when complete Remarks Items not completed at the time of the check will be completed within... days of the date shown below. Time arrived... Time left.. Technician s Signature... Date.... Customer s / Customer Representative s Signature... NCP 104 Attachment 5 30
33 National Security Inspectorate Sentinel House 5 Reform Road MAIDENHEAD SL6 8BY Tel: or Fax: Website:
maintenance of CCTV surveillance systems code of practice
maintenance of CCTV surveillance systems code of practice Issue 3 January 2015 For other information please contact: British Security Industry Association t: 0845 389 3889 f: 0845 389 0761 e: [email protected]
Code of Practice for Planning, Installation and Maintenance of Access Control Systems ICP 30
Code of Practice for Planning, Installation and Maintenance of Access Control Systems ICP 30 This Code of Practice is to be read in conjunction with the NSI Systems Silver Regulations relating to approval
Surveillance, Security & CCTV: A Buyer s Guide
Surveillance, Security & CCTV: A Buyer s Guide -2- SECURITY SURVEILLANCE SYSTEMS Security surveillance equipment, more commonly referred to as CCTV equipment, is not just for large corporations anymore.
Fire. The Fire Installers Mate. A guide to fire alarm systems design
Fire The Fire Installers Mate A guide to fire alarm systems design BS 5839 Part 1:2002 A guide to BS 5839 Part 1:2002 Disclaimer This booklet is not intended to be a comprehensive guide to all aspects
National Security Inspectorate. NSI Code of Practice for Design, Installation and Maintenance of Access Control Systems NCP 109
National Security Inspectorate NSI Code of Practice for Design, Installation and Maintenance of Access Control Systems NCP 109 This Code of Practice is to be read in conjunction with the NSI Regulations
planning, design, installation and operation of CCTV surveillance systems code of practice and associated guidance
planning, design, installation and operation of CCTV surveillance systems code of practice and associated guidance Issue 4 July 2014 For other information please contact: British Security Industry Association
BS5839 Part 1:2002 Overview
BS5839 Part 1:2002 Overview 1 Contents Introduction So why is the current standard being revised? The brief for the new standard Changes to structure of current Standard Enhanced certification of Fire
SELECTING THE CCTV SECURITY SYSTEM THAT IS RIGHT FOR YOU
SELECTING THE CCTV SECURITY SYSTEM THAT IS RIGHT FOR YOU When buying a security camera or complete CCTV system you need to consider the main purpose of the system. For example, is it to be used for: Observation
T855 Day & Night Security Camera
T855 Day & Night Security Camera For use with Swann 4500 DVR EN INSTRUCTION MANUAL MT855_091014E Swann 2014 Before you begin Introduction Congratulations on your purchase of this T850 Day & Night Security
How To Comply With The Loss Prevention Certification Board
Loss Prevention Standard LPS 1014: Issue 5.3 This Loss Prevention Standard is the property of BRE Global Ltd. and is made publicly available for information purposes only. Its use for testing, assessment,
ISO IEC 27002 2005 (17799 2005) INFORMATION SECURITY AUDIT TOOL
9.1 USE SECURITY AREAS TO PROTECT FACILITIES 1 GOAL Do you use physical methods to prevent unauthorized access to your organization s information and premises? 2 GOAL Do you use physical methods to prevent
National Security Inspectorate NACOSS Gold Supplementary Code of Practice for the Planning, Installation and Maintenance of Intruder Alarms NACP 11
National Security Inspectorate NACOSS Gold Supplementary Code of Practice for the Planning, Installation and Maintenance of Intruder Alarms NACP 11 This Code of Practice applies to companies holding NACOSS
Dome Security Camera with IR night vision
Dome Security Camera with IR night vision EN INSTRUCTION MANUAL 1 Before you begin Limited Warranty Terms & Conditions Swann Communications warrants this product against defects in workmanship and material
INFORMATION ON STANDARDS FOR ELECTRONIC SECURITY SYSTEMS
INFORMATION ON STANDARDS FOR ELECTRONIC SECURITY SYSTEMS This is an uncontrolled document. The purpose of this document is to list the primary technical standards that NACOSS Gold and Systems Silver approved
Policing requirements for Closed Circuit Television
Policing requirements for Closed Circuit Television 1 Policing requirements for Closed Circuit Television Policing requirements for Closed Circuit Television 2 Closed circuit television (CCTV) systems
PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE
MODEL HAA51 PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE OPERATING MANUAL HAA51 PASSIVE INFRARED INTRUDER DETECTOR INTRODUCTION HAA51 Passive Infrared
AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839
AVAILABLE TO DOWNLOAD ON THE APOLLO APP a guide to Fire Alarm Systems Design BS5839 Part1:2013 The Regulatory Reform (Fire Safety) Order (FSO) became law on 1 October 2006 Legally you must comply! What
Special Specification 6033 Computerized Transportation Management System
6033 Special Specification 6033 Computerized Transportation Management System 1. DESCRIPTION Relocate computerized transportation management system (CTMS) equipment as shown on the plans and as described
For the Design, Installation, Commissioning & Maintenance of Fixed Gaseous Fire Suppression Systems
BAFE Scheme: SP203-3 Version 1: July 2008 Amendment No: 1 Fire Protection Industry Scheme, Reference SP203 Part 3 For the Design, Installation, Commissioning & Maintenance of Fixed Gaseous Fire Suppression
FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10
TECHNICAL SPECIFICATIONS Page 1 of 10 FIRE DETECTION AND ALARM SYSTEM Scope Furnish a complete 24V DC conventional, electrically supervised, zone annunciated, fire detection and alarm system as specified
SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC5451. www.lorextechnology.com
SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC5451 www.lorextechnology.com Contents 1x Camera and mounting stand 1x Power adapter 1x Mounting kit 1x Allen key 1x Screw cap 1x 60 ft. (18m)
38. ACCESS CONTROL AND ELECTRONIC SECURITY SYSTEM
38. ACCESS CONTROL AND ELECTRONIC SECURITY SYSTEM 38.1 GENERAL Scope Modification and extension of the existing CDU Cardax security system and CCTV System including: Cardax (FT 3000 series) Access control
Bold items are particular to the City of Euless
EULESS FIRE DEPARTMENT FIRE MARSHAL S OFFICE INFORMATION LINE: Revised 2/12 Fire Chief Wes Rhodes Fire Marshal Paul Smith EFD-FMO 3-2 2009 International Fire & Building Code as Amended NFPA Standards Adopted
integration of intruder alarm systems with other systems under PD 6662 a guide
integration of intruder alarm systems with other systems under PD 6662 a guide July 2013 For other information please contact: British Security Industry Association t: 0845 389 3889 f: 0845 389 0761 e:
UBC Technical Guidelines Section 17900 2015 Edition Secure Access: General Standards Page 1 of 7
Page 1 of 7 1.0 GENERAL 1.1 Related UBC Guidelines.1 Section 17910, 17920 and 17930.2 Section 17100 Cable Infrastructure Overview, sub sections 1.4.9 and 1.5.3 Section 17110 Communication Rooms, sub section
CCTV Monitoring - Terms and conditions, scope of work
1. Where specified in a Contract for Monitoring Services, and provided that the Customer complies with it obligations under our terms and conditions for CCTV monitored services. Paramount SG shall use
LOOK to us because we re. Advice for your domestic security. nsi.org.uk
LOOK to us because we re looking out for you Advice for your domestic security nsi.org.uk Can you afford not to secure your home? Most of us don t think about the implications of a break-in or the need
12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting
12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.
Fire Alarm Systems Care and Maintenance
April 2011 Country of Origin: United Kingdom Fire Alarm Systems Care and Maintenance Introduction A fire alarm installation is designed to provide early warning of a fire condition. To ensure that the
High definition day/night
PROFESSIONAL High definition day/night security CAMERA HIGH DEFINITION 600 TVL colour CAMERA DELIVERING HIGH QUALITY VIDEO with accurate colour rendition POWERFUL NIGHT VISION 24 INFRA-RED LEDs FOR NIGHT
Standard the the Raising
Raising the Standard Introduction to BS 5839-1:2013 An Overview of the BS 5839 1:2013 for professionals who are responsible for the provision of fire detection and alarm systems for buildings Agenda Introduction
REPLACEMENT AIR CONDITIONING UNITS FOR BRITISH EMBASSY RESIDENCE
REPLACEMENT AIR CONDITIONING UNITS FOR BRITISH EMBASSY RESIDENCE FOREIGN & COMMENWEALTH OFFICE BE BAHRAIN TEL: MAY 2014 EMAIL: TENDER ISSUE: 002/2014 1. GENERAL REQUIREMENTS 1.01 LOCATION OF SITE The British
INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT
INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT FIRE EXTINGUISHERS,SPRINKLER SYSTEMS AND FIRE ALARMS Attachment #1 Inspection of Fire Extinguishers Fire Extinguishers must be tested according
FIRE DETECTION AND ALARM SYSTEMS
HMO Information Sheet No 1 FIRE DETECTION AND ALARM SYSTEMS 1. Introduction When a property is in multiple occupation, the risk of fire breaking out is greater than in an ordinary single family home. Some
CalMod Design-Build Electrification Services
SECTION 28 16 00 INTRUSION DETECTION SYSTEM PART 1 - GENERAL 1.1 DESCRIPTION A. This section describes the detailed technical requirements for the Intrusion Detection System (IDS), where the Contractor
ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1
KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1 PART 1 - GENERAL 1.01 RELATED DOCUMENTS: SECTION 16050 A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1
INTRUSION ALARM SYSTEM
INTRUSION ALARM SYSTEM Case studies reveal most burglars are deterred by the mere presence of an alarm system. Burglars attack unprotected premises considerably more often than ones protected by alarm
SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines
PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting
D/N VARI-FOCAL IR CAMERA
D/N VARI-FOCAL IR CAMERA PIH-0364X/0368X/0384X/0388X W/S INSTRUCTION MANUAL IMPORTANT SAFEGUARDS 1. Read Instructions All the safety and operating instructions should be read before the unit is operated.
ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems
ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems Content Introduction Preventing unauthorized access by perimeter surveillance Monitoring unauthorized access by indoor surveillance
Advanced Fencing and Security Technologies Ltd
G.M. Advanced Fencing and Security Technologies Ltd P.O. Box 2327 Kfar Sava Industrial Area 44425, Israel Tel +972-9-7662965 Fax + 972-9-7662964 E-mail: [email protected] Website: www.gmsecurity.com
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
Surveillance Security Camera Guide
Surveillance Security Camera Guide By Guy Avital DVRMASTER.COM All Rights Reserved A BUYERS GUIDE TO SURVEILLANCE SECURITY CAMERA SYSTEMS There are a variety range of security cameras, security DVR and
GUIDE TO SPECIFYING A CCTV SYSTEM
GUIDE TO SPECIFYING A CCTV SYSTEM Introduction This paper is aimed at the end user and is guidance on avoiding some of the pitfalls created by a poorly structured or ill thought-out specification. You
Your Canadian Security Specialists. Eddie D Orazio
Your Canadian Security Specialists Eddie D Orazio Commercial Sales Structured Security Systems Toll Free: 1-888-693-1118 Tel: 905-640-0069 Fax: 905-576-2836 Mobile: 905-424-0050 [email protected]
Loss Prevention Standard
Loss Prevention Standard : ISSUE 3.0 Requirements for the LPCB Approval and Listing of Companies Undertaking the Maintenance and Repair of Doorsets, Shutters, and Active Smoke/Fire Barriers This standard
Video Security Systems Designer
Video Security Systems Designer Level II Certification Content Outline National Institute for Certification in Engineering Technologies Introduction The purpose of this certification program is to recognize
Day / Night IR Color Camera User Manual V2.1.0
Day / Night IR Color Camera User Manual V2.1.0 1 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to DS-2CC102P(N)-IR1(IR3)(IR5),
A customer s guide to BS 8418 detector-activated remotely monitored CCTV systems
A customer s guide to BS 8418 detector-activated remotely monitored CCTV systems May 2016 For other information please contact: British Security Industry Association t: 0845 389 3889 e: [email protected]
Fire Alarm System Plans Submittal Guidelines For New and Existing Systems
Fire Alarm System Plans Submittal Guidelines For New and Existing Systems SCOPE The Temecula Fire Prevention Bureau (TFPB) has established the following requirements for the submittal of all fire alarms,
ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK. Website www.iomfire.com
ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK Website www.iomfire.com ADDRESS OF PREMISES FIRE CERTIFICATE No. (where applicable).. LOCATION OF LOG BOOK. CONTENTS OF LOG BOOK Useful telephone
D/N VANDAL RESISTANT 700TVL VARI-FOCAL IR DOME CAMERA CMR6082X/6082MX3.6 N/P CMR6086X/6086MX3.6 N/P
D/N VANDAL RESISTANT 700TVL VARI-FOCAL IR DOME CAMERA CMR6082X/6082MX3.6 N/P CMR6086X/6086MX3.6 N/P INSTRUCTION MANUAL IMPORTANT SAFEGUARDS CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE
Remote Monitoring and Control of Traffic Control Equipment via a Telecommunications Network
traffic systems and signing TR 2522 Issue A October 2005 Remote Monitoring and Control of Traffic Control Equipment via a Telecommunications Network Crown Copyright 2005 First published 2005 Printed and
Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM
Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM Hycontrol Limited, Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, UK. Tel: +44 (0)1527 406800 Fax:
Regulation IO-6.0: Electrical Safety Regulations
Regulation IO-6.0: Electrical Safety Regulations 6.1 Workmanship & Material 6.2 Electrical Conductors 6.3 Overcurrent Protective Devices 6.4 Precautions against Earth Leakage and Earthfault Currents 6.5
Utilities and existing services
Construction Services Building standards for mechanical and electrical installations Utilities and existing services October 2012 Directorate: Environment Construction Services - Building standards for
UNIVERSITY COLLEGE LONDON CCTV POLICY. Endorsed by the Security Working Group - 17 October 2012
UNIVERSITY COLLEGE LONDON CCTV POLICY Endorsed by the Security Working Group - 17 October 2012 Endorsed by the Infrastructure IT Services Strategy Group - 18 October 2012 Reviewed and endorsed (with one
aseries A13B Mini Bullet Camera User Manual
aseries A13B Mini Bullet Camera User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to the MicroView
Specifying an IT Cabling System
Specifying an IT Cabling System This guide will help you produce a specification for an IT cabling system that meets your organisation s needs and gives you value for money. You will be able to give your
SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS
SECTION 16721 FIRE ALARM AND DETECTION SYSTEMS The equipment requirements of this section apply to the IUB Campus. The IUPUI Campus has a preferred vendor agreement for fire alarm systems. Contact Pat
NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide
NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series en Quick Install Guide NEI-30 VEI-30 Dinion Infrared Imager Table of Contents en 3 Table of Contents 1 Planning 4 1.1 Hardware Requirements 4 1.2 Pre-installation
Telemetry system for cathodic protection equipment of underground metal pipelines
RECOMMENDATION PCRA 009 June 2010 Rev. 0 Committee for Cathodic Protection and Associated Coatings Telemetry system for cathodic protection equipment of underground metal pipelines DISCLAIMER: The present
Section 6 Fire Detection and Alarm Systems Russell Porteous Chief Executive Officer Firewize Services
Section 6 Fire Detection and Alarm Systems Russell Porteous Chief Executive Officer Firewize Services General Information Section 6 of AS1851-2012 covers: Fire Detection and Alarms Systems Electrical Detection
Solar Panel Installations
Solar Panel Installations Page 1 of 6 SINGLE-FAMILY RESIDENTIAL CHECKLIST City of Hayward Development Services Department Revised: 7-09-15 PERMIT REQUIREMENTS Permits are required for all solar panel installations.
Axis network cameras A wide portfolio of products for professional video surveillance.
Axis network cameras A wide portfolio of products for professional video surveillance. The market s widest range of network cameras The video surveillance market is thriving, driven by increased public
NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems
NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems 1.0 Purpose A. The following guideline provides the minimum standards and requirements for fire alarm systems. 2.0
SECTION 16760 - PLANT INTERCOMMUNICATION SYSTEM. City of San Diego, CWP Guidelines
PART 1 - GENERAL SECTION 16760-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing plant intercommunication systems with power supplies, signal amplifiers,
DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)
DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations) DETAILS OF THE CLEINT Client and address ADDRESS OF THE INSTALLATION Installation
Closed Circuit Television (CCTV) code of practice. Based on the publication A Code of Practice for CCTV www.ico.gov.uk
Closed Circuit Television (CCTV) code of practice Based on the publication A Code of Practice for CCTV www.ico.gov.uk Owner: Ian Heywood Last reviewed: July 2011 Contents 1.0 Introduction... 4 2.0 CCTV
CORRECTIONAL SERVICES CANADA TECHNICAL SERVICES BRANCH ELECTRONIC SECURITY SYSTEMS ELECTRONIC ENGINEERING STANDARD FIXED OUTDOOR CAMERA ENCLOSURE
CORRECTIONAL SERVICES CANADA TECHNICAL SERVICES BRANCH ELECTRONIC SECURITY SYSTEMS Revision 2 ELECTRONIC ENGINEERING STANDARD FIXED OUTDOOR CAMERA ENCLOSURE FOR USE IN FEDERAL CORRECTIONAL INSTITUTIONS
Perimeter Security System
TM Perimeter Security System The Next Generation Perimeter Security System ICRONET combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience. It is a sophisticated
CFP 2/4/8 ZONE CONVENTIONAL FIRE ALARM CONTROL PANEL. user manual & log book. Approved Document No. DFU7001020 Rev 1
CFP 2/4/8 ZONE CONVENTIONAL FIRE ALARM CONTROL PANEL user manual & log book Approved Document No. DFU7001020 Rev 1 CONTENTS Safety...3 Important information regarding the safe use of this fire alarm panel
INSPECTION AND TESTING OF FIRE ALARM SYSTEMS
Page 1 January 2, 2009 INSPECTION AND TESTING OF FIRE ALARM SYSTEMS Introduction Early warning plays a key role in a healthcare facility s ability to safely evacuate its residents during a fire emergency.
VdS 5473en : 2006-09 (01) Video Surveillance Systems (CCTV)
VdS 5473en : 2006-09 (01) Video Surveillance We wish to thank the Police, in particular the Kommission Polizeiliche Kriminalprävention der Länder und des Bundes - KPK (German Police commitee for crime
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
PDF Created with deskpdf PDF Writer - Trial :: http://www.docudesk.com
CCTV Lens Calculator For a quick 1/3" CCD Camera you can work out the lens required using this simple method: Distance from object multiplied by 4.8, divided by horizontal or vertical area equals the lens
EVIDENCE PHOTOGRAPHY TEST SPECIFICATIONS MODULE 1: CAMERA SYSTEMS & LIGHT THEORY (37)
EVIDENCE PHOTOGRAPHY TEST SPECIFICATIONS The exam will cover evidence photography involving crime scenes, fire scenes, accident scenes, aircraft incident scenes, surveillances and hazardous materials scenes.
Middleborough Police Electronic Security Narrative
Middleborough Police Electronic Security Narrative 1. PURPOSE The purpose of this document is to define specific security, access control and surveillance requirements for the exterior and interior of
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
Islington ICT Physical Security of Information Policy A council-wide information technology policy. Version 0.7 June 2014
Islington ICT Physical Security of Information Policy A council-wide information technology policy Version 0.7 June 2014 Copyright Notification Copyright London Borough of Islington 2014 This document
Building Technologies
Building Technologies Passive infrared detectors: Safe detection of unwanted visitors. Efficient security systems by Siemens. Many demands are made on the protection of people and property against burglary,
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS Before you install or use the apparatus, you must read and understand these Important Safety Instructions. At all times when using the apparatus you must follow these Important
SYSTEMS SILVER APPROVAL CRITERIA
SYSTEMS SILVER APPROVAL CRITERIA These Criteria are to be read in conjunction with the Regulations relating to Systems Silver Approval. No Company shall hold out or claim that it meets Systems Silver Approval
Release: 1. CPPSEC3020A Monitor security from control room
Release: 1 CPPSEC3020A Monitor security from control room CPPSEC3020A Monitor security from control room Modification History Not Applicable Unit Descriptor Unit descriptor This unit of competency specifies
Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual
0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security
Engineers Edge, LLC PDH & Professional Training
510 N. Crosslane Rd. Monroe, Georgia 30656 (770) 266-6915 fax (678) 643-1758 Engineers Edge, LLC PDH & Professional Training Copyright, All Rights Reserved Engineers Edge, LLC An Introduction to Communication
FIRERAY 2000 Installation Guide
FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description
Totally Wireless Video Security
Traditional Video Surveillance ($50,000+) vs. Event-Based Videofied Solution ($2,500) Executive Summary: Totally Wireless Video Security has been effective but cost and complexity has limited deployment
Alarm Systems. The purpose of an intruder alarm system is: Commonly utilised detection devices include:
Alarm Systems An intruder alarm system is designed to detect intruder presence at your premises. When detected, a siren will activate and communicate an alarm signal to one of our highly sophisticated
Conventional Fire Detection and Extinguishant Control System Specification
Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
IP Matrix MVC-FIPM. Installation and Operating Manual
IP Matrix MVC-FIPM en Installation and Operating Manual IP Matrix IP Matrix Table of Contents en 3 Table of Contents 1 Preface 5 1.1 About this Manual 5 1.2 Conventions in this Manual 5 1.3 Intended Use
Security Technician Certification Program
Security Technician Certification Program Forms part of the Certificate II in Technical Security CPP 20307 Introduction to the Program Incorporating AS 2201.1:2007 AS/ACIF S008:2006 AS/ACIF S009:2006 Telstra
FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.
Polk School District Specifications for the New Fire Alarm in the Existing Building Eastside Elementary School FIRE ALARM SYSTEM 1.01 SUBMITTALS A. Shop drawings shall be submitted as follows: 1. Manufacturer's
How To Use A Ds340 (Dsp)
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
FIREFINDER XLS ADDRESSABLE FIRE ALARM SYSTEM SECTION 13851
FIREFINDER XLS ADDRESSABLE FIRE ALARM SYSTEM SECTION 13851 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
SECTION 16721 FIRE ALARM AND SMOKE DETECTION SYSTEMS
SECTION 16721 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Fire Alarm Control Panels B. Manual Fire Alarm Stations C. Automatic Smoke D. Fire Alarm Notification Appliances E. Auxiliary Fire Alarm Equipment
TESTING AND COMMISSIONING PROCEDURE FOR BURGLAR ALARM AND SECURITY INSTALLATION GOVERNMENT BUILDINGS THE HONG KONG SPECIAL ADMINISTRATIVE REGION
TESTING AND COMMISSIONING PROCEDURE FOR BURGLAR ALARM AND SECURITY INSTALLATION IN GOVERNMENT BUILDINGS OF THE HONG KONG SPECIAL ADMINISTRATIVE REGION 2007 EDITION ARCHITECTURAL SERVICES DEPARTMENT THE