A Novel Ultrasonic Dynamic Drainage Tester
|
|
|
- Jonathan Jones
- 10 years ago
- Views:
Transcription
1 A Novel Ultrasonic Dynamic Drainage Tester Jinlan Ju 2, Xujun Hua 1, and Huining Xiao 2 1 FPInnovations Pulp and Paper Division, Pointe-Claire, QC, Canada 2 Department of Chemical Engineering, University of New Brunswick, Fredericton, NB, Canada ABSTRACT The Dynamic Drainage Jar (DDJ) is commonly used to assess furnish drainage. However, contrary to the drainage process in a commercial paper machine, drainage in a DDJ normally occurs without turbulence because any impeller mixing increases filtration resistance enormously. A novel Ultrasonic Dynamic Drainage Jar (UDDJ) has been developed to simulate the dynamic drainage conditions found in the forming section of a paper machine. In the UDDJ, ultrasound is directly imparted to the Jar, causing it to oscillate and produce turbulence near the screen. The apparatus is able to simultaneously measure drainage, retention, and web porosity. The influence of ultrasound on fines retention and drainage behaviour of a newsprint furnish were investigated at various impeller mixing speeds in the absence and presence of a cationic retention aid. The results indicated that the ultrasonic forces applied in UDDJ were able to prevent blocking of the filtration screen, to deflocculate the pulp, and to create and enlarge dewatering channels in the forming web. As a result, the ultrasound accelerated pulp drainage, reduced fines retention and produced a more porous web. In this manner, UDDJ resembles the drainage elements of a paper machine, although no low frequency pressure pulses were generated. The UDDJ could be a very useful laboratory tool to determine the drainage performance of furnishes and chemical additives under dynamic conditions. INTRODUCTION In paper manufacture about 99% of the water in paper furnish is removed in the forming and press sections and the rest is evaporated in the drying section. Although the drying section removes only about 1% of the water, it is the largest energy user in the paper machine. It was reported that each percent of reduction in sheet moisture entering the drying section reduces drying cost by 4-5% [1,2]. In addition, web moisture content determines the strength of the wet web, which in turn affects machine runnability. Therefore, fast drainage is desirable for good paper machine runnability and for decreasing the overall production cost. To promote fines retention and improve paper machine drainage, polymeric additives and other chemicals are commonly used in the machine wet-end. The effectiveness of these chemicals as a drainage aid is often established in laboratory tests prior to any machine trials. Thus, a reliable laboratory drainage tester would be very useful for the development and applications of the additives, and for the optimization of wet-end chemistry. BACKGROUND The Canadian Standard Freeness (CSF) tester is often used to characterize pulp drainage. The CSF tester measures the rate at which a pulp with a consistency of.3% is drained by gravity [3]. Although CSF is a useful tool for pulp quality control and for comparing pulp stocks, the results obtained with the freeness tester often show little correlation with the drainage of the stock on a paper machine wire. Clark [4] pointed out that the drainage of the thin agitated web on a paper machine wire was affected more by the wet compressibility of the fibers and less by the fines content when compared to the thick and quiescent mat formed in the freeness tester. Awareness of the freeness tester s limitations led researchers to develop alternative drainage tests to measure drainage under turbulent conditions. In the early 7s, Britt developed the Dynamic Drainage Jar (DDJ) in which, turbulence is introduced by an impeller rotating at a high speed [5]. The DDJ has been proven to be a useful tool to study first-pass retention, and is used in a standard method to determine fines content of paper stock [6]. Due to its simplicity and small specimen requirement, the DDJ is widely applied in the pulp and paper industry. For a drainage measurement, the DDJ is usually modified to allow the application of vacuum beneath the forming mat [7-1]. Several modified DDJ versions are commercially available, for instance, the Dynamic Drainage Analyzer (DDA) produced by AB Akribi Kemikonsulter [11] and the Muteck DFR-4 from BTG Muteck GmbH [12]. Though these devices are claimed to be dynamic drainage testers, the drainage is actually performed under static conditions because the agitation is stopped prior to dewatering [13]. It is observed that the fines retention is higher and drainage is slower when using a DDJ tester compared to commercial paper machines where dewatering proceeds under high PaperCon 211 Page 291
2 turbulence. The lack of turbulence and shear forces in a DDJ causes that the drainage responds to polymeric additives more dramatically than in a paper machine. Thus, although modified DDJ s can provide a rough guide as to how pulp stocks drain, they do not simulate the dynamic drainage conditions in the forming section of a paper machine. During the initial stage of dewatering in the forming zone of a paper machine, pressure and vacuum pulses are generated by forming foils and rolls. Each pressure pulse disrupts the web structure and opens water passages. The subsequent vacuum pulses wash away fines and accelerate dewatering. To simulate this pressure pulsation, the Moving Belt Drainage Tester (MBDT) was developed at Helsinki University of Technology in the early nineties [14,15] and later modified to allow for the collection of the sheet formed by the apparatus [16]. The MBDT consists of a cogged belt, moving between a stationary forming wire and vacuum box. The moving cogs provide scraping action and upward pulses to the wire above, while the gaps between pairs of cogs act as suction slits. The MBDT imitates the conditions on a Fourdrinier wire more realistically than a conventional DDJ. The z-directional filler distribution of the formed sheet was found to be close to that produced by a Fourdrinier machine. However, the MBDT only monitors a part of the drainage process, giving no information on the initial dewatering stage prior to the wet line. The sheets formed by the MBDT are also much wetter than those leaving the couch of a commercial machine. In addition, the level of turbulence cannot be controlled due to limitations on belt speed [14,15]. Despite these shortcomings, the MBDT represents an appreciable step towards the simulation of dynamic conditions of a commercial paper machine. Another drainage tester simulating pressure pulsation in the forming section is the Pulsed Drainage Device (PDD) developed by Betz PaperChem [17,18]. Instead of using a moving belt, pulsation is generated by a rotating hydrofoil located directly beneath the circle-shaped wire of the PDD. An inherent drawback of this approach is the nonuniformity of pressure pulsation along the radius of the forming wire. Nevertheless, the PDD method gives a more complete picture than the CSF and DDJ by producing drainage time, vacuum response, retention, and a handsheet in one trial. Clearly, there is still a need to have an improved laboratory drainage tester which should be able to incorporate turbulence during drainage and overcome the limitations of the existing methods. The objective of this work was to explore a new way of generating turbulence by applying ultrasound energy. This report describes a prototype of an ultrasonic assisted DDJ, and the effect of ultrasound on retention and drainage. It is shown that ultrasound induces additional turbulence and accelerates the furnish drainage rate while avoiding the pitfalls of the conventional DDJs. Ultrasound and Its Applications Ultrasound is acoustic waves traveling through a medium at a frequency higher than that which human ears can detect. Frequencies are usually greater than 2 khz [19]. In a commercial ultrasonic device, ultrasound is generated by a transducer which commonly uses a piezoelectric crystal. The piezoelectric properties make the crystal vibrate when rapid reversing electric charges are applied to it. Absorption of acoustic energy by a fluid could result in acoustic streaming (or fluid flow) and produce turbulence. Apart from acoustic streaming, the fluid is subject to alternating rarefaction and compression cycles resulting from the propagation of ultrasonic waves [2]. At a sufficiently high power, the rarefaction cycle may exceed the tensile strength of the fluid so that a bubble cavity is formed. These ultrasonic effects have been successfully used to disperse particles in liquid and to increase the filtering rate [21]. Ultrasound has been broadly used in cleaning, laboratory mixing, welding, biological cellular dismembrating and sensor technologies, but very rarely in the pulp and paper industry, although some research work has been done. For instance, ultrasound has been considered to enhance recycled pulp deinking, pulp refining, clarification of water streams, and the measurement of pulp consistency and paper stiffness [22]. Jong et al. applied ultrasound to thicken a pulp by redirecting the fibre movement in the flow [23]. Mckay and Aidun employed ultrasonic waves to disrupt fibre mats and to refluidize pulp on simulated forming board in an attempt to enhance dewatering and formation [24]. The Prototype of an Ultrasonic Dynamic Drainage Jar (UDDJ) The ultrasound-assisted drainage testing apparatus, as sketched in Figure 1, was developed based on a modified DDJ system manufactured by the FPInnovations-Paprican Division. It is composed of a drainage jar, a filtration collecting flask, a vacuum pump, a balance and a computer. The drainage jar consists of an upper plastic chamber PaperCon 211 Page 292
3 and a lower base. The two parts are threaded to fit each other and to hold an ultrasonic filtration screen made of a stainless steel wire of 6-mesh. An ultrasonic horn is connected laterally to the screen frame which also functions as a resonant ring. The resonant ring generates turbulence in the pulp and the entire system. In this way, ultrasound energy is evenly spread over the entire screen and its frame in order to avoid over-intensive ultrasonic forces near the tip of a conventional laboratory ultrasonic mixer. It is expected that the ultrasound produces three primary effects by wave propagation: (1) turbulence in the pulp that is intended to reduce colloidal flocculation; (2) acoustic forces on the forming mat that increase drainage channels and promote fines and water migration through the channels; (3) deblinding or unblocking on the screen. Ultrasound may be applied or stopped at any point throughout the drainage process. The amplitude of ultrasound can be adjusted between 2% and 1% of the maximum power. For a drainage experiment, the sample is added to the DDJ and pre-mixed using an impeller. The pre-mixing imitates the approach system in a commercial machine while the subsequent filtration stage simulates the wire section. During drainage, the shear force and turbulence are generated by the impeller and ultrasonic oscillations. The device allows drainage testing to be conducted under various levels of vacuum. During drainage, the weight of filtrate is monitored with a balance and the vacuum level under the screen is measured with a pressure transducer. The weight and pressure data are automatically recorded, and processed by a computer to produce drainage profiles of the tested furnish. screen Ultrasound Horn Impeller Vacuum Gauge Vacuum Pump Balance Figure 1. Schematic of the Ultrasonic Dynamic Drainage Jar (UDDJ) system. EXPERIMENTAL Materials A newsprint furnish (TMP) provided by a Canadian paper company was used in this work. The pulp consistency was around 5%. The CSF of the TMP was 12 ml and its average fibre length was 1.51 mm. The fines content (FC) of the pulp was 38.9%, which was measured according to TAPPI T261 cm-. An aqueous chitosan solution prepared at a concentration of.1% was employed as a polymeric retention aid. The dosage of chitosan was.5 g/kg fibre (o.d.). Retention Without Mat Formation First-pass retention (FPR) and fines retention without mat formation (R f ) were measured at room temperature using the UDDJ. To avoid mat forming, the filtrate flow-rate was restricted to 2 ml/min. The distance between the impeller blade and the screen was set at 3 mm. Before testing, the pulp was diluted with deionized water to a consistency of.2%. Then, 5 g of the diluted pulp suspension was poured into the UDDJ with mixing at a specified impeller speed between -15 rpm. The filtration valve was opened after 15 seconds of mixing and the PaperCon 211 Page 293
4 mixing continued during the filtration. In some tests, ultrasound was applied from the time of valve opening, until the end of drainage. To determine fines retention, the first 1 g of filtrate was collected. Collected filtrate was filtered through a pre-weighed glass fibre filter paper to retain the fines, then the filter paper was oven-dried and weighed. This procedure gave the weight of fines in the filtrate. FPR was calculated according to Equation 1: FPR = (C p *W filtrate - W fines )/ C p *W filtrate (1) where C p is the pulp consistency and W filtrate and W fines refer to the weight of the filtrate collected and the weight of fines in the filtrate, respectively. The fines retention, R f, was calculated according to Equation 2: where FC is the fines content of the pulp. R f = (C p *FC *W filtrate - W fines )/ C p *FC *W filtrate (2) Measurement of Drainage and Retention with Mat Formation The drainage measurement was conducted using the UDDJ at the agitator speed of either 4 rpm or 1 rpm. A pulp slurry at 2% consistency was first premixed for 15 seconds in the jar. If chitosan was used, the suspension was agitated for another 2 seconds. After the premixing period, the drainage valve was opened, and pre-mixing was stopped, or continued if turbulence conditions were needed. The filtrate drained into a flask which had a vacuum level of 2 mmhg. Ultrasound could be applied during the drainage. Combinations of ultrasound with mixing during drainage create four categories of drainage conditions with different degrees of turbulence as listed in Table I. The no-turbulence testing conditions were equivalent to those of a conventional DDJ. Table I: Turbulence conditions imparted during drainage testing Category No turbulence Mixing Ultrasound Ultrasound +Mixing Description of Turbulence conditions Stop mixing when drainage valve was opened. No ultrasound was applied. Continue mixing at the same speed as premixing during drainage. No ultrasound was applied. Stop mixing but start ultrasound at the moment that drainage valve was opened Continue mixing and start ultrasound when drainage valve was opened The drainage profiles based on both filtrate weight and vacuum pressure in the UDDJ were recorded and processed with a computer. The fines were separated from the filtrate at the end of drainage to quantify the fines retention. The drainage time was defined as the time needed to reach the inflection point on the filtrate profile curve calculated by the second derivative of the weight-time curve. The first-pass retention and fines retention with mat formation (R fm ) were calculated in the same way as described earlier. Fibre Quality Analysis Mat formed on the screen of the drainage tester was split into five layers using a Beloit sheet splitter. Each layer was disintegrated in deionized water, and analysed using a Fibre Quality Analyzer (FQA - LDA2 from OpTest Equipment Inc). Length-weighted length (L w ) and length-weighted fines content (C lw ) were calculated according to Equations 3 and 4, respectively [25]. L w = ( N i L 2 i )/( N i L i ) (3) C lw = ( n k L k )/ ( N i L i ) (4) PaperCon 211 Page 294
5 Where: i and k = 1, 2,.m categories N i = fibre number in the i th category L i = fibre length in the i th category n k = number of fines whose length was less than.2 mm in the k th category L k = fines length in the k th category RESULTS AND DISCUSSION 1. Effect of Impeller Mixing on DDJ Drainage Test The primary function of the drainage elements on paper machines is to accelerate dewatering. In the initial stage of mat formation, the drainage elements generate pressure pulses and produce turbulence to disrupt the fibrous mat, and to prevent over-flocculation of the fibres. These pulses also reduce the effect of retention aids. To imitate the dynamic drainage conditions on paper machines, turbulence should, therefore, be included into a drainage tester. For the conventional DDJ, the rotating impeller is a direct and simple way to generate turbulence in the draining pulp, and to disrupt the mat formed. One might expect that such mixing should lead to accelerated drainage if it functions like machine drainage elements. In order to determine the effect of mixing, the drainage profiles of a newsprint furnish were determined when impeller mixing was applied during the drainage. The drainage curves were compared to those obtained without mixing. Figure 2 shows the influence of impeller speed on the drainage behaviour of the newsprint furnish. Contraintuitively, the impeller agitation applied during dewatering actually slowed down the filtration rate, resulting in prolonged drainage time. When drainage was tested without turbulence, that is, the mixing stopped at the beginning of drainage, the drainage time was 14.1 s. When drainage was measured with mixing continued during drainage at an impeller speed of 4 rpm, the drainage time increased to 17. s. The drainage time of the same pulp was prolonged to 38.1 s when agitated at 1 rpm. Obviously, increasing mixing speed reduced drainage rate. 4 No mixing 14.1s Filtrate Weight (g) Mixing at 4rpm 17.s Mixing at 1 rpm 38.1s Time (sec) Figure 2. Influence of impeller speed on the drainage behaviour of a newsprint furnish. The numbers under the legends are drainage time. PaperCon 211 Page 295
6 To better understand this phenomenon, fines distribution in the mat obtained from drainage testing under continuous mixing was analyzed with a Fibre Quality Analyzer (FQA). As shown in Figure 3, fines content decreased from the wire side to the top side of the mat. The fines content was 26.6% in the wire-side layer and only 7.7% in the top layer. The average fibre length (L w ) in the respective layers was.95 mm and 1.82 mm. During drainage under rapid mixing and vacuum, pulp suspension was exposed to a strong downward force produced by vacuum and to a centrifugal force from the impeller s rotation. Fines passed through the wire more easily than fibres, but some would be trapped in the openings of the wire and contribute to the initial mat. On the other hand, fibres on the surface of the forming mat were more easily swept off by the impeller and returned to the pulp suspension. As the mat built up, fines migrated toward the wire side with water flow and tended to clog the pores and interstices of the mat, while fibres could not so easily migrate through the mat due to their large size. Consequently, fines were more concentrated on the wire side. The z-direction fines distribution of the mat formed in a DDJ under impeller mixing was actually the converse of that of a commercial paper, where the wire-side contains fewer fines [15]. Therefore, a rotating impeller alone is not a suitable turbulent generator for drainage testing. To simulate more closely machine drainage, other means of generating turbulence and de-clogging are required Fines Content (%) Wire side Thickness (mm) Top side Figure 3. Fines distribution of a sheet formed in a DDJ under continuous mixing. 2. The Effects of Ultrasound on Screen Unblocking and Deflocculation To explore the effect of ultrasound on deflocculation and screen-unblocking, the operating conditions of UDDJ were set up in such a way that mat formation was avoided by limiting drainage flow to 2 ml/min, similar to those conditions used in a conventional DDJ for retention tests. The first-pass fines retention of the newsprint furnish (at.2% consistency) was measured under various impeller mixing speeds with and without application of ultrasound. As shown in Figure 4, first-pass fines retention decreased as mixing speed increased, and reached a minimum level at about 5 rpm. No further decrease in retention was observed beyond this speed. Thus, 5 rpm is sufficient to deflocculate and avoid mat formation under the conditions used in this work. At the same impeller mixing speeds, applying ultrasound reduced fines retention. The greatest impact was observed when the mixing speed was below 5 rpm. The ultrasound reduced the fines retention up to 3%. The lowering of retention could be attributed to deflocculation, mat disruption and screen-unblocking effect from the applied ultrasound. When the mixing speed was 5 rpm or higher, the effect of ultrasound levelled off, resulting in a roughly constant reduction in retention of about 5.5%. At these speeds, the impeller mixing itself was sufficient to destroy flocs and fibre mat, so the effect of ultrasound was diminished, and limited to its function of screen-unblocking. PaperCon 211 Page 296
7 1 Fines Retention (%) Without ultrasound With ultrasound Impeller Rotating Speed (rpm) Figure 4. First-pass fines retention of the untreated TMP furnish (.2% cons.) as a function of impeller rotating speed with and without ultrasound. Chitosan (poly[β-(1 4)-2-amino-2-deoxy-D-glucopyranose]) is a linear, high-molecular-weight aminopolysaccharide with a structure similar to cellulose. Under slightly acidic conditions, the primary amine group on each glucose moiety renders chitosan cationic, and enables it to interact with negative-charged cellulose fibres and fines as a retention aid [26]. To verify whether ultrasonic forces were able to destroy the flocs induced by retention aids, fines retentions of TMP treated with chitosan were measured. The results are presented in Figure 5. As expected, fines retention dramatically increased in the presence of chitosan. However, flocs were degraded by intensive shear force, especially when mixing speed was higher than 5 rpm. In addition to mixing, ultrasound further reduced the fines retention of the chitosan-treated samples to levels similar to those of untreated samples in the absence of ultrasound (see Figure 4). The effect of ultrasound was most pronounced at a mixing speed of about 4 rpm. Mixing with impeller at this speed was not sufficient to destroy the flocs induced by chitosan. However, applying ultrasonic forces at this mixing level reduced fines retention from 73% to 24%, a reduction of 49%. If the unblocking effect of ultrasound is assumed to be 5.5% as mentioned earlier, the additional reduction of 43.5% in fines retention may be caused mainly by the deflocculation effect of ultrasound. Clearly, ultrasonic forces are capable of destroying flocs induced by polymers. It was observed that the effect of ultrasound was influenced by the weight of the sample. As shown in Figure 6, without ultrasound, the first-pass retention was independent of pulp weight. When ultrasound was used, however, FPR varied with the weight of the pulp. The retentions of 35 g of pulp furnish were lower in general than those of 5 g of pulp furnish (.2% cons.). Therefore, ultrasound is more effective with a smaller sample. This is understandable because the intensity of ultrasonic forces increases as the sample becomes smaller. To maximize the effect of ultrasound, 35 g of pulp furnish was employed in the subsequent drainage tests. 3. Effect of Ultrasound on the Drainage Behaviour of TMP In sheet formation on a paper machine, drainage, retention and formation are influenced by mechanical entrapment of fines elements and by flocculation of fibres, fines and fillers. However, the fines retention discussed in the previous section excludes the influence of mechanical entrapment because of the absence of mat formation during drainage. To obtain a complete view of the drainage and retention performance of a papermaking furnish in the presence of a chemical aid, it is necessary to characterize its performance with mat formation. PaperCon 211 Page 297
8 1 Fines Retention (%) With ultrasound Without ultrasound Impeller Rotating Speed (rpm) Figure 5. The first pass fines retention of the chitosan-treated TMP as a function of impeller rotating speed with and without ultrasound. 1 9 Without ultrasound 35g and 5g of pulp furnish FPR (%) 8 With ultrasound 5 g of pulp furnish 7 35 g of pulp furnish Impeller Speed (rpm) Figure 6. The effect of ultrasound on retention depends on sample weight. 3.1 Drainage with low premixing speed (4 rpm) As shown in section 2, ultrasonic deflocculation was dominant at 4 rpm. Thus, to maximize the ultrasound effect, the drainage behaviour of the TMP was investigated following a premixing at 4 rpm in this part of work. After premixing, the pulp was exposed to various turbulent draining conditions including: no mixing, mixing at 4 rpm, ultrasound, and ultrasound plus mixing at 4 rpm (see Table I for details). The drainage profiles under each condition are shown in Figure 7. At the beginning of the drainage, when the filtrate was less than 6 g, all the curves were overlapping, indicating that the drainage velocities were the same for all mixing intensities. Afterwards the drainage velocities deviated from one another, probably due to the changes in mat structure under different turbulences. As a result, drainage time varied. Without turbulence, the UDDJ acts as a conventional DDJ, and the drainage time tested was 14.1 s. Continuous mixing at 4 rpm increased drainage time to 17. s, whereas ultrasound reduced the drainage time to 11.5 s. With the combination of ultrasound and mixing, drainage time was longer than that without mixing but shorter than that observed for agitated DDJ. PaperCon 211 Page 298
9 4 No mixing 14.1s Filtrate Weight (g) Ultrasound 11.5s Mixing at 4rpm 17.s Mixing at 4 rpm & ultrasound 15.9s Time (sec) Figure 7. Drainage profiles of a newsprint furnish at various mxing intensities with a low premixing speed (4rpm) in the absence of additives. The corresponding fines retention without mixing and ultrasound was 77.6%, much higher than the typical fines retention found on a commercial machine which is often below 4% [26]. This high retention was due to the lack of turbulence and increased mechanical trapping. Application of ultrasonic forces reduced mechanical trapping, resulting in a decrease in fines retention, to 64.2%. The effect on mechanical trapping is dependent on ultrasound intensity. As illustrated in Figure 8, as the amplitude of ultrasound increased, the fines retention measured with the UDDJ was reduced further. Overall, ultrasonic forces affect drainage and retention in three ways: screen unblocking, deflocculating, and prevention of fines entrapment during mat formation. Therefore, ultrasonic forces act in a way similar to the drainage elements of a commercial paper machine. 9 Fines Retention (%) Untreated TMP Chitosan Treated TMP Ultrasound Amplitude (%) Figure 8. Fines retention as a function of ultrasonic amplitude. PaperCon 211 Page 299
10 Table II shows the drainage times when chitosan was used. The drainage times were shortened in the presence of chitosan due to pulp flocculation, except when ultrasound was applied. In the presence of ultrasound, drainage times with and without chitosan were similar. This similarity is related to the increase in fines retention when chitosan was used. Without ultrasound, chitosan treatment only increased fines retention by 11% and 8% because a large amount of fines were trapped in the mat. Under these conditions, the contribution of flocculation induced by chitosan to retention was relatively unimportant. Under the influence of ultrasound, the mechanical entrapment of fines was reduced. The flocculation by polymer became more important, which led to a greater increase of fines retention, by about 17%. Thus, chitosan did not improve drainage in the presence of ultrasound because the acceleration of drainage induced by flocculation was counteracted by high fines retention. This counteractive behaviour brought by polymer addition was undetectable using a conventional DDJ. Table II: Comparison of drainage time and retention between chitosan-treated and untreated pulps with premixing at 4 rpm. sample No mixing Mixing at Mixing at 4 Ultrasound 4 rpm rpm + ultrasound Drainage time (s) Untreated pulp Chitosan-treated pulp Fines retention with mat formation (%) Untreated pulp Chitosan-treated pulp Increase in fines retention by chitosan (%) Drainage with high premixing speed (1 rpm) Because the turbulent forces generated by mixing at 4 rpm are much weaker than those encountered in the wetend of a commercial paper machine [27], the drainage behaviour of a pulp was studied under a high premixing speed (1 rpm) using the UDDJ. The results are shown in Figure 9. Similar to the results obtained at 4 rpm, ultrasound accelerated drainage whereas mixing prolonged drainage time. Compared to that achieved with mixing only, ultrasound reduced drainage time by a factor of 3. The order of drainage time ( t ) was: t (ultrasound) < t (ultrasound/mixing) < t (no mixing) << t (mixing) These results further support the argument that impeller mixing alone does not generate the proper turbulence to simulate machine drainage. Ultrasound is able to introduce additional shear forces into pulp without impeding drainage. Different from its impact on drainage under low speed premixing, the addition of chitosan at high premixing speed failed to improve drainage velocity under the first three mixing conditions as shown in Table III. On the other hand, chitosan still improved fines retention (also shown in Table III). The high pre-mixing speed might have reduced polymer-induced flocculation. The reduced flocculation and increased fines retention are probably the reasons why chitosan failed to improve drainage under these conditions. It is interesting to note under the combination of both ultrasound and high speed mixing, the fines retention was reduced significantly, to a level similar to that found in commercial paper machines. Under high mixing intensity, chitosan increased fines retention by only ~ 5%. As expected, chitosan was able to shorten drainage time, from 1.7 s to 9.4 s in this case, when the increase in fines retention was not great. These results illustrate that the UDDJ may be used to simulate various turbulence conditions occurring at the wet-end of fast paper machines by a proper combination of ultrasound and mixing. Only under these high turbulence conditions, can the functions of polymeric additives be estimated realistically. PaperCon 211 Page 3
11 4 Filtrate Weight (g) No mixing, 11.7 s Mixing at 1 rpm, 38.1 s Ultrasound, 1. s Ultrasound & mixing at 1 rpm 1.7s Time (sec) Figure 9. Drainage profile of the newsprint furnish at 1 rpm. Table III: Comparison of the drainage time and fines retention between chitosan-treated and untreated pulps under premixing at 1 rpm. Sample No mixing Mixing Ultrasound at 1 rpm Drainage time (s) Mixing at 1 rpm + ultrasound Untreated pulp Chitosan-treated pulp Fines retention with mat formation (%) Untreated pulp Chitosan-treated pulp Increase in the fines retention by chitosan (%) Figure 1 shows the pressure profiles of the corresponding drainage curves of Figure 9. In general pressure first decreased (higher vacuum), and then fluctuated, except for the curve obtained under continuous shearing at 1 rpm. The vacuum became constant afterwards, which was defined as the equilibrium vacuum whose value reflects the porosity of the wet web [18]. The first pressure peak during the pressure fluctuation usually corresponded to the wet line in web formation. It is interesting to observe that pressure profiles under various drainage conditions were very different. When pulp was drained with mixing, the equilibrium vacuum was higher because more fines blocked the screen and the wire-side web, resulting in a much more closed web and a lower drainage rate, as discussed in the first section. In contrast, applying ultrasound made the web more porous as evidenced by the lower vacuum. Due to the loose structure of the web formed with ultrasound, the filtration resistance was low and water drained more rapidly. The correlation between equilibrium vacuum and drainage time is shown in Figure 11. For comparison, the corresponding fines retention was also plotted against the drainage time. Clearly, drainage time was more correlated with equilibrium vacuum pressure, than to the fines retention. Since the equilibrium vacuum pressure reflects the porosity and compressibility of forming sheet, the higher correlation indicates that the web structure plays a more important role in drainage than the fines content, like in commercial paper machines [4]. PaperCon 211 Page 31
12 Pressure (kpa) -1-2 Ultrasound Ultrasound & mixing at 1 rpm No turbulence Mixing at 1rpm -3 Time (sec) Figure 1. Pressure profile of the newsprint furnish at various turbulence conditions corresponding to Figure Vacuum Pressure (kpa) 2 1 Fines Retention R 2 =.455 Equilibrium Vacuum R 2 = Fines Retention (%) Drainage Time (s) Figure 11. Logarithmic Correlations of drainage time to equilibrium vacuum pressure and fines retention. 3.3 Mechanism of Drainage under Various Turbulences As shown in the previous section, applying ultrasound increased drainage rate and reduced fines retention, while mixing with an impeller had the opposite effect. Based on the drainage behaviours and mat structure, the drainage processes in the presence of ultrasound or mixing are schematically depicted in Figure 11. PaperCon 211 Page 32
13 A: Before starting drainage test B: Dewatering under mixing C: Dewatering under ultrasound Figure 12. The proposed schematic of dewatering under various turbulent conditions. The red small circles represent fines, the blue ovals symbolize the fibres, and the bottom dashed line indicates the forming wire. Before drainage starts, both fibres and fines are evenly dispersed. When the pulp is drained while mixing, some fines are readily trapped by the wire and form the initial mat. Because the fines fill up the pores and interstices, the drainage rate is low and the formed web has low permeability. When the pulp is drained in the presence of ultrasound, the fines go through the wire more easily with less entrapment of fines in the openings of the wire and in the formed web, resulting in a more porous web, faster drainage, and reduced fines content in the web. CONCLUDING REMARKS An Ultrasonic Dynamic Drainage Jar (UDDJ) has been developed for studying the drainage performance of papermaking furnishes by directly generating ultrasonic vibration in the tester. The UDDJ generates both drainage and pressure profiles instantaneously. The drainage time can be computed based on these profiles. The vacuum level at the end of drainage reflects web porosity and compressibility. The first-pass retention can be determined by measuring the fines concentration in the filtrate. The preliminary results show that the ultrasonic forces produced by UDDJ are able to deflocculate pulp suspension, to reduce fines retention, to accelerate drainage processes and to produce porous wet web, while these functions cannot be achieved by the conventional impeller mixing alone. By applying ultrasound together with impeller mixing, UDDJ can be used to simulate various turbulence conditions occurring at the wet-end of a fast paper machine, so that the performance of polymeric additives can be assessed under more realistic conditions. The results suggest the effect of ultrasound in the UDDJ includes the following three aspects: 1. Unblocking forming wire and retarding the formation of the initial mat. 2. Deflocculating the pulp suspension. 3. Creating or enlarging dewatering channels in the forming web. The ultrasonic DDJ can simulate the drainage in the paper machine former better than commercially available laboratory testers. It is also conceivable that ultrasound could be potentially used in the forming section of a real paper machine to accelerate its drainage rate. The Ultrasonic DDJ possesses several additional advantages over the conventional DDJs: 1. The intensity of turbulence can be easily controlled by adjusting the amplitude of ultrasonic power. The amplitude and the acting time can both be programmed to simulate the varying turbulence conditions along the forming section. 2. The apparatus is able to simultaneously measure drainage, retention, and web porosity. There is also the potential to obtain handsheets made under dynamic conditions. 3. Unlike impeller mixing, the ultrasound could act on a very thin layer of pulp suspension, which provides possibilities to make handsheets at high consistency and low basis weight. PaperCon 211 Page 33
14 Thus, the UDDJ could be a very useful laboratory tool to evaluate the drainage performance of furnishes and chemical additives under dynamic conditions. The future work includes optimization and automation of the device, and validation of the results using a pilot paper machine. ACKNOWLEDGEMENTS The authors are indebted to the following staff members of FPInnovations Paprican Division who helped with the improvements of the initial drainage apparatus, on which the current UDDJ is based: G. Dorris and G. Laivins for the auto-measurement of filtrate weight, T. Owston and M. Drainville for the pressure sensor, C. Castro for the data processing program, T. Owston for the primary application of ultrasound on drainage testing, and Istvan Tihanyi and Normand Vignola for the manufacture of the UDDJ. The authors are also grateful to many colleagues for their useful comments and suggestions regarding this work, especially M. Laleg, J. Jong, I. Vadeiko, T. Owston, and S. Middleton. This work was carried-out under a post graduate program by the University of New Brunswick and was partially supported by the NSERC IPS program. REFERENCES 1. Hoyland, R.W., The Role of the Press Section in Energy Conservation, Paper Technology and Industry, 19(1): (1978). 2. Gess, J.M., United States Patent 4,613,46 (1986). 3. TAPPI T 227 om-4, Freeness of Pulp (Canadian Standard Method) (24). 4. Clark, J.D A, Freeness Fallacies and Facts, Svensk Papperstidning 73(3): (197). 5. Britt, K.W., Mechanisms of Retention during Paper Formation, Tappi 56(1): 46 (1973). 6. TAPPI T 261 cm-, Fines Fraction of Paper Stock by Wet Screening (2). 7. Britt, K.W., Unbehend, J.E. and Holman, J.C., Dynamic Drainage of Paper Stock, Tappi J. 65(11): (1982). 8. Abson, D., Predicting the Performance of Shear-Sensitive Additives, Tappi J. 63(6): 55-58(198). 9. Springer, A.M., Chandrasekaran, S. and Wegner, T.H., The Influence of Starch on Drainage and Retention in Paperboard Mill Systems, Tappi J. 67(2): (1984). 1. Unbehend, J.E., Laboratory Drainage Testers A Critical Review, 199 Tappi Papermakers Conference, (199). 11. The Dynamic Drainage Analyzer Manual, AB Akribi Kemikonsulter, Sundsvall, Sweden (21). 12. Chabot B. and Daneault C.A., Methodology of Determine Retention and Drainage in Laboratory, Paperi ja Puu/Paper and Timber, 86(6): (24). 13. Krogerus, B., Laboratory Testing of Retention and Drainage, in Papermaking Chemistry, edited by Leo Neimo, Fapet Oy, (1999). 14. Karrila, S., Raisanen, K., and Paulapuro, H., The Moving Belt Drainage Tester (MBDT), 1992 Tappi Papermakers Conference, (1992). PaperCon 211 Page 34
15 15. Raisanen, K. and Paulapuro, H., Wire Section Simulation with the Moving Belt Drainage Tester (MBDT), 1993 Tappi Papermakers Conference, (1993). 16. Mitchell, C., Parker, I. and Johnston, R., Development of the Moving Belt Sheet Former/Drainage Tester, 56th Appita Annual General Conference, Rotorua, New Zealand, (22). 17. Lin, J.T. and Schuster, M.A., et al., Apparatus for Simulation Processing Parameters and Predicting Variables in a Papermaking Operation Including Sequential Pulsation, Gravity and Vacuum Drainage, Fines Retention and Paper Formation, US Patent (1994). 18. Sutman, F.J., Development and Validation of an Improved Drainage Testing Methodology, Tappi, 83(4): 69-7 (2). 19. Kuttruff, H., Applications of High Intensity Ultrasound in Ultrasonics Fundamentals and Applications, Elsevier Science Publishers Ltd., London and NewYork, (1991). 2. Lamminen, M.O., Walker, H.W., and Weavers, L.K., Mechanism and Factors Influencing the Ultrasonic Cleaning of Particle-Fouled Ceramic Membranes, J. Membrane Sci., 237, (24). 21. Mason, T.J. and Lorimer J.P., Miscellaneous Effects of Power Ultrasound in Sonochemistry: Theory, Applications and Uses of Ultrasound in Chemistry, Ellis Horwood Ltd., Chichester, England, (1988). 22. Brodeur, P.H. and Gerhardstein, J.P., Overview of Applications of Ultrasonics in the Pulp and Paper Industry, IEEE Ultrasonics Symposium, (1998). 23. Jong, J.H. and Choi, M.M., et al., Acoustic Separation of Moving Fibers in a Pulp Flow, 1999 TAPPI Pulping Conference, (1999). 24. Paul Mckay and Cyrus K.Aidun, Refluidization of Wood Fiber Mats with High Intensity Ultrasound, TAPPI Paper Summit, Spring Technical and International Environmental Conference, 3-5 (24). 25. OpTest Equipment Inc., Operation Manual, Fiber Quality Analyzer Code LDA2 (1999). 26. Laleg, M. and Pikulik, I.I., Wet-Web Strength Increase by Chitosan, Nordic Pulp and Paper Research Journal, 6(3): (1991). 27. Britt, K.W., Unbehend, J.E., and Shridharan, R., Observations on Water Removal in Papermaking, Tappi Journal, 69(7): (1986). PaperCon 211 Page 35
PLEASE SCROLL DOWN FOR ARTICLE
This article was downloaded by: [University of Minnesota] On: 8 April 2009 Access details: Access Details: [subscription number 788736612] Publisher Taylor & Francis Informa Ltd Registered in England and
Standard Test Procedures Manual
STP 206-4 Standard Test Procedures Manual Section: 1. SCOPE 1.1. Description of Test This method describes the procedure for determining the liquid limit, plastic limit and the plasticity index of coarse-grained
Filter Aid Filtration
Filter Aid Filtration Filtration is the separation of solids from liquids by forcing the liquid to flow through a porous medium and depositing the solids on the medium. A filter aid (finely divided material
Flash Mixing, fast and simple way to introduce wet end additives efficiently into papermaking process
Flash Mixing, fast and simple way to introduce wet end additives efficiently into papermaking process 2. 1. Jouni Matula Wetend Ltd Savonlinna Finland 1 (8) Flash Mixing, fast and simple way to introduce
Improvement in the Retention and Strength of Paper Made from White-grade Wastepaper
Improvement in the Retention and Strength of Paper Made from White-grade Wastepaper Ji Young Lee, a Eun Hye Kim, b and Yong Joo Sung c, * White ledger is white-grade recycled pulp that replaces the bleached
Characteristics of Floc: Interplay between Retention Aid and Hydrodynamic. Forces Effects in Fines Flocculation
Characteristics of Floc: Interplay between Retention Aid and Hydrodynamic Forces Effects in Fines Flocculation Mohammad. R. Abdallah/Qasaimeh AlBalqa Applied University, AlHuson University College, Chemical
SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS
SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS Published in Water and Waste Digest membrane issue, November 2008 Miroslav Colic; Chief Scientist, Clean Water Technology
New Insights into Gap Forming of Lightweight Containerboard
New Insights into Gap Forming of Lightweight Containerboard Frank Swietlik, Jukka Muhonen, Ari Puurtinen, Hannu Turpeinen, Teuvo Virkkunen Metso, Paper business line ABSTRACT This presentation gives new
CONTROL SYSTEMS, ROBOTICS, AND AUTOMATION - Vol. XIX - Automation And Control Of Pulp And Paper Processes - H. N. Koivo
AUTOMATION AND CONTROL OF PULP AND PAPER PROCESSES Helsinki University of Technology, Espoo, Finland Keywords: Paper machine, mechanical pulp, chemical pulp, digester, recovery boiler, grinder, stone groundwood,
Interpretation of clogging effects on the hydraulic behavior of ion treated geotextiles
9 th International Conference on Geosynthetics, Brazil, 2010 Interpretation of clogging effects on the hydraulic behavior of ion treated geotextiles Lee, K. W. Department of Civil Engineering, Dongseo
It is an important tool to assess factors that affect the bioavailability of a drug from a solid preparartion.
Quality control of tablets Dissolution It is an important tool to assess factors that affect the bioavailability of a drug from a solid preparartion. To ensure that the preparation comply with product
Sterilization methods and equipment Lab 1-2
Sterilization methods and equipment Lab 1-2 PHT 434 Sterilization Sterilization a process that by which all viable M.O are removed or destroyed, based on a probability function. Sterilization concept Sterilization
Welding of Plastics. Amit Mukund Joshi. (B.E Mechanical, A.M.I.Prod.E)
Welding of Plastics Amit Mukund Joshi (B.E Mechanical, A.M.I.Prod.E) Introduction Mechanical fasteners, adhesives, and welding processes can all be employed to form joints between engineering plastics.
BIOMEDICAL ULTRASOUND
BIOMEDICAL ULTRASOUND Goals: To become familiar with: Ultrasound wave Wave propagation and Scattering Mechanisms of Tissue Damage Biomedical Ultrasound Transducers Biomedical Ultrasound Imaging Ultrasonic
Evaluation of Initial Setting Time of Fresh Concrete
Evaluation of Initial Setting Time of Fresh Concrete R R C Piyasena, P A T S Premerathne, B T D Perera, S M A Nanayakkara Abstract According to ASTM 403C, initial setting time of concrete is measured based
Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers
Flow and Flow rate. Laminar and Turbulent flow Laminar flow: smooth, orderly and regular Mechanical sensors have inertia, which can integrate out small variations due to turbulence Turbulent flow: chaotic
KEMFORM, POSSIBILITY TO IMPROVE PRODUCTIVITY OF THE MACHINES FOR PRINTING AND PACKAGING GRADES
KEMFORM, POSSIBILITY TO IMPROVE PRODUCTIVITY OF THE MACHINES FOR PRINTING AND PACKAGING GRADES Matti Hietaniemi Kemira Research Scientist Espoo, Finland Marcus Lillandt Kemira Sr Research Scientist Espoo,
Vacuum dewatering of paper SPCI Convention September 2013
Vacuum dewatering of paper SPCI Convention September 2013 Karlstad University Content of presentation - Energy consumption of vacuum systems - Influence of vacuum dwell time and vacuum level - at Karlstad
Stock Preparation Division: The C-bar screen basket a high-tech product
14 Stock Preparation Division: The C-bar screen basket a high-tech product According to an old saying: paper is made in the Holländer. Despite the common opinion that paper mills only contain paper machines,
Dispersion of Synthetic Fibers in Wet-Lay Nonwovens
Dispersion of Synthetic Fibers in Wet-Lay Nonwovens This article was written by James M. Keith, retired Director of Technical Services for MiniFIBERS, and published in the Tappi Journal, Vol. 77, No. 6,
METHOD OF TEST FOR DETERMINATION OF PERMEABILITY OF GRANULAR SOILS
Laboratory Testing Manual Date: 99 06 21 Page 1 of 7 METHOD OF TEST FOR DETERMINATION OF PERMEABILITY OF GRANULAR SOILS 1. SCOPE 1.1 This method covers the determination of the coefficient of permeability
Performance prediction of a centrifugal pump working in direct and reverse mode using Computational Fluid Dynamics
European Association for the Development of Renewable Energies, Environment and Power Quality (EA4EPQ) International Conference on Renewable Energies and Power Quality (ICREPQ 10) Granada (Spain), 23rd
Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications
Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications Janet E. Semmens Sonoscan, Inc. 2149 E. Pratt Boulevard Elk Grove Village, IL 60007 USA Phone: (847)
Development of New Inkjet Head Applying MEMS Technology and Thin Film Actuator
Development of New Inkjet Head Applying MEMS Technology and Thin Film Actuator Kenji MAWATARI, Koich SAMESHIMA, Mitsuyoshi MIYAI, Shinya MATSUDA Abstract We developed a new inkjet head by applying MEMS
Novel Press Fabric Cleaning Method Increases Productivity in a Sustainable Manner
Novel Press Fabric Cleaning Method Increases Productivity in a Sustainable Manner Dave Kelso Senior Account Manager DuBois Chemical ([email protected]) John Schwamberger Paper Chemicals Division
Estimation of impact of alternative papermaking additives on paper web dewatering intensity and paper properties
Aleksandra Judasz 128573 Faculty of Chemistry Technical University of Lodz Papermaking and printing Estimation of impact of alternative papermaking additives on paper web dewatering intensity and paper
Improving the yield of soybean oil extraction process by using of microwave system
Improving the yield of soybean oil extraction process by using of microwave system M. Ghazvehi, M. Nasiri* School of Chemical, Gas and Petroleum Engineering, Semnan University,Semnan, Iran The increasing
Free Fall: Observing and Analyzing the Free Fall Motion of a Bouncing Ping-Pong Ball and Calculating the Free Fall Acceleration (Teacher s Guide)
Free Fall: Observing and Analyzing the Free Fall Motion of a Bouncing Ping-Pong Ball and Calculating the Free Fall Acceleration (Teacher s Guide) 2012 WARD S Science v.11/12 OVERVIEW Students will measure
Outotec HIGmills; A Fine Grinding Technology
23 rd International Mining Congress & Exhibition of Turkey 16-19 April 2013 ANTALYA Outotec HIGmills; A Fine Grinding Technology H. Lehto Outotec Finland Oy A. Paz Outotec Pty Ltd, Perth, Australia I.
T 549. WORKING GROUP CHAIRMAN N/A; reaffirmed SUBJECT RELATED
NOTICE: This is a DRAFT of a TAPPI Standard in ballot. Although available for public viewing, it is still under TAPPI s copyright and may not be reproduced or distributed without permission of TAPPI. This
Rock Bolt Condition Monitoring Using Ultrasonic Guided Waves
Rock Bolt Condition Monitoring Using Ultrasonic Guided Waves Bennie Buys Department of Mechanical and Aeronautical Engineering University of Pretoria Introduction Rock Bolts and their associated problems
PART I SIEVE ANALYSIS OF MATERIAL RETAINED ON THE 425 M (NO. 40) SIEVE
Test Procedure for PARTICLE SIZE ANALYSIS OF SOILS TxDOT Designation: Tex-110-E Effective Date: August 1999 1. SCOPE 1.1 This method covers the quantitative determination of the distribution of particle
associates Precision Cleaning Systems 3678 Bassett St., Santa Clara CA 95054 Phn: [ 408 ] 727 8388 Fax: [ 408 ] 727 8991 E-Mail tony@tmasc.
associates Precision Cleaning Systems www.tmasc.com 3678 Bassett St., Santa Clara CA 95054 Phn: [ 408 ] 727 8388 Fax: [ 408 ] 727 8991 E-Mail [email protected] Basic Facts on Ultrasonic Cleaning Process Description
Building Design for Advanced Technology Instruments Sensitive to Acoustical Noise
Building Design for Advanced Technology Instruments Sensitive to Acoustic Noise Michael Gendreau Colin Gordon & Associates Presentation Outline! High technology research and manufacturing instruments respond
PAGE 2. Figure 1: Difference between PWL ins and SPL 1m
PAGE 1 Pipe noise J.H. Granneman and R.P.M. Jansen, Peutz Consulting Engineers, The Netherlands, emphasise the need for an adequate pipe noise control procedure, with reference to the design phase, insulation
Heat. LD Physics Leaflets. Determining the adiabatic exponent c P /c V of various gases using the gas elastic resonance apparatus P2.5.3.
WZ 013-06 Heat Kinetic theory of gases Specific heat of gases LD Physics Leaflets P..3. Determining the adiabatic exponent c P /c V of various gases using the gas elastic resonance apparatus Experiment
INJECTION MOLDING COOLING TIME REDUCTION AND THERMAL STRESS ANALYSIS
INJECTION MOLDING COOLING TIME REDUCTION AND THERMAL STRESS ANALYSIS Tom Kimerling University of Massachusetts, Amherst MIE 605 Finite Element Analysis Spring 2002 ABSTRACT A FEA transient thermal structural
Testing and appraisal of Lucobit polymer effect as an additive on asphalt mixture performance
Abstract Testing and appraisal of polymer effect as an additive on asphalt mixture performance Hamid Sabbagh mollahosseini*,golazin Yadollahi**, Ershad Amoosoltani*** *, ***Executive of Engineering and
AMPLITUDE AND FORCE PROFILING: STUDIES IN ULTRASONIC WELDING OF THERMOPLASTICS
AMPLITUDE AND FORCE PROFILING: STUDIES IN ULTRASONIC WELDING OF THERMOPLASTICS David A. Grewell Branson Ultrasonics Corporation ABSTRACT This paper reviews effects of amplitude and force control during
The Theory of HPLC. Gradient HPLC
The Theory of HPLC Gradient HPLC i Wherever you see this symbol, it is important to access the on-line course as there is interactive material that cannot be fully shown in this reference manual. Aims
Optimizing Tank Cleaning Operations
Optimizing Tank Cleaning Operations Choosing the best way to thoroughly clean your tanks while minimizing use of costly chemicals, water and manual labor can be challenging. There are several things you
Experiment (13): Flow channel
Introduction: An open channel is a duct in which the liquid flows with a free surface exposed to atmospheric pressure. Along the length of the duct, the pressure at the surface is therefore constant and
Papermaking PAPERMACHINE PRESSING
1. INTRODUCTION Papermaking PAPERMACHINE PRESSING The paper web formed on the wire part or the forming section passes onto the press section. Pressing of the web on the paper machine follows entering of
Lecture slides on rolling By: Dr H N Dhakal Lecturer in Mechanical and Marine Engineering, School of Engineering, University of Plymouth
Lecture slides on rolling By: Dr H N Dhakal Lecturer in Mechanical and Marine Engineering, School of Engineering, University of Plymouth Bulk deformation forming (rolling) Rolling is the process of reducing
Automatic Back-Flushing Filter AutoFilt RF9.
Automatic Back-Flushing Filter AutoFilt RF9. AutoFilt RF9 Clearing the Way. The Challenge: In response to the Tier III standard which will come into effect in 2016, the International Maritime Organization
Machine needle shut-off nozzle type-a
Machine needle shut-off nozzle type-a spring operated Applications: Thermoplastics (not applicable for PVC) Shut-off mechanism: Operated with one axial high performance spring Index of contents Chapter
Enhanced Organic Precursor Removals Using Aged Filter Media Page 1. Enhanced Organic Precursor Removals Using Aged Filter Media
Enhanced Organic Precursor Removals Using Aged Media Page 1 Enhanced Organic Precursor Removals Using Aged Media O b j e c t i v e s The main goals of this project was to evaluate the dissolved organic
Vibration Isolation in Data Centers
Vibration Isolation in Data Centers Vibrations in Data Centers Vibrations in Data Centers can be produced by nearby construction works, heavy traffic, railways or even the own cooling units inside or next
Radial-axial Radial mixing is based on the premise that the fluids to be mixed enter the mixer in the correct proportions simultaneously
Brochure E-0501 1 Introduction. Static mixers are used for a wide range of applications including mixing, heat exchange and dispersion, due to numerous unique innovations our products are especially suitable
Analysis of free reed attack transients
Analysis of free reed attack transients James Cottingham Physics Department, Coe College, Cedar Rapids, Iowa, United States Summary Attack transients of harmonium-type free reeds from American reed organs
EcoCWave. The all-round talent for aqueous part cleaning. www.durr.com
EcoCWave The all-round talent for aqueous part cleaning www.durr.com Part cleaning as a value-adding value-adding process process Increasing demands on cleanliness in component manufacturing impose a need
STRATEGIES FOR HIGH VACUUM DEWATERING ON PAPER MACHINES
STRATEGIES FOR HIGH VACUUM DEWATERING ON PAPER MACHINES Ravi Pandey and A.K.Ray Saharanpur Campus Department of Paper Technology Indian Institute of Technology Roorkee, India ABSTRACT The Paper machine
Common Defects in Digital Printing. Paul Geldenhuys & Amir Shapira January, 2009
Common Defects in Digital Printing Paul Geldenhuys & Amir Shapira January, 2009 Overview Ambient Influences Humidity Temperature Sunlight & UV Abrasion Chemical Resistance Common Defects in Digital Printing
The Effects of Certain Polymers on Tensile strength and Tension Relaxation of Wet Web
The Effects of Certain Polymers on Tensile strength and Tension Relaxation of Wet Web Salminen, K. 1, Kataja-aho, J. 2, Lindqvist, H. 3, Retulainen, E. 2, Rantanen, T. 2 and Sundberg, A. 3 1) VTT Technical
Flocking of textiles. Flocked shirt 13. flocking drying cleaning. adhesive. application. creation
Flocking of textiles > The motif flocking is the high-class alternative to textile printing. One not only flocks sports wear for schools, sport clubs, associations etc., but also fabrics for garments,
PASSIVE CONTROL OF SHOCK WAVE APPLIED TO HELICOPTER ROTOR HIGH-SPEED IMPULSIVE NOISE REDUCTION
TASK QUARTERLY 14 No 3, 297 305 PASSIVE CONTROL OF SHOCK WAVE APPLIED TO HELICOPTER ROTOR HIGH-SPEED IMPULSIVE NOISE REDUCTION PIOTR DOERFFER AND OSKAR SZULC Institute of Fluid-Flow Machinery, Polish Academy
v = fλ PROGRESSIVE WAVES 1 Candidates should be able to :
PROGRESSIVE WAVES 1 Candidates should be able to : Describe and distinguish between progressive longitudinal and transverse waves. With the exception of electromagnetic waves, which do not need a material
PEGRES project. Paper, bioenergy and Green chemicals from nonwood RESidues by a novel biorefinery. Juha Tanskanen
Paper, bioenergy and Green chemicals from nonwood RESidues by a novel biorefinery A Nonwood Biorefinery Paper, bioenergy and green chemicals from nonwood residues by a novel biorefinery Leader of the consortium
FORMATION DAMAGE AND WELL TREATMENT SYSTEM
FORMATION DAMAGE AND WELL TREATMENT SYSTEM FDWTS-10K Includes ability to test Liquid Permeability & Gas Permeability Fines migration & critical velocity Static Filtration Drilling mud invasion evaluation
THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST
THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST Instruction: Check each test method for which you are requesting accreditation. An asterisk beside the NVLAP Test Method Code indicates that proficiency
Piezoelectric Driven Non-toxic Injector for Automated Cell Manipulation
Medicine Meets Virtual Reality 18 J.D. Westwood et al. (Eds.) IOS Press, 2011 2011 The authors. All rights reserved. doi:10.3233/978-1-60750-706-2-231 231 Piezoelectric Driven Non-toxic Injector for Automated
DryWeight BulkVolume
Test Procedure for BULK SPECIFIC GRAVITY AND WATER ABSORPTION OF AGGREGATE TxDOT Designation: Tex-201-F Effective Date: January 2016 1. SCOPE 1.1 Use this method to determine the bulk specific gravity
Physical Science Study Guide Unit 7 Wave properties and behaviors, electromagnetic spectrum, Doppler Effect
Objectives: PS-7.1 Physical Science Study Guide Unit 7 Wave properties and behaviors, electromagnetic spectrum, Doppler Effect Illustrate ways that the energy of waves is transferred by interaction with
On the Mean Flow Pore Size Distribution of Microfiber and Nanofiber Webs
ORIGINAL PAPER/PEER-REVIEWED On the Mean Flow Pore Size Distribution of Microfiber and Nanofiber Webs By Dr. Norman Lifshutz, Senior Research Fellow, Hollingsworth & Vose Co. Abstract A nonwoven fibrous
Using Computational Fluid Dynamics (CFD) Simulation to Model Fluid Motion in Process Vessels on Fixed and Floating Platforms
Using Computational Fluid Dynamics (CFD) Simulation to Model Fluid Motion in Process Vessels on Fixed and Floating Platforms Dr. Ted Frankiewicz Dr. Chang-Ming Lee NATCO Group Houston, TX USA IBC 9 th
DIESEL EFFECT PROBLEM SOLVING DURING INJECTION MOULDING
RESEARCH PAPERS FACULTY OF MATERIALS SCIENCE AND TECHNOLOGY IN TRNAVA SLOVAK UNIVERSITY OF TECHNOLOGY IN BRATISLAVA 2014 Volume 22, Special Number DIESEL EFFECT PROBLEM SOLVING DURING INJECTION MOULDING
DUPONT PERFORMANCE POLYMERS Joint Design: A Critical Factor in Strong Bonds GENERAL GUIDELINES FOR ULTRASONIC, VIBRATION AND SPIN WELDING
DUPONT PERFORMANCE POLYMERS Joint Design: A Critical Factor in Strong Bonds GENERAL GUIDELINES FOR ULTRASONIC, VIBRATION AND SPIN WELDING Introduction Welding techniques for assembling parts molded with
Installation PowerPoint for Grasscrete Formers
Installation PowerPoint for Grasscrete Formers 1 This document describes the two single-use tools utilized to create the Grasscrete product. The original Former is a vacuum formed light gauge plastic mold
APPLICATION OF TRANSIENT WELLBORE SIMULATOR TO EVALUATE DELIVERABILITY CURVE ON HYPOTHETICAL WELL-X
PROCEEDINGS, Thirty-Third Workshop on Geothermal Reservoir Engineering Stanford University, Stanford, California, January 8-30, 008 SGP-TR-185 APPLICATION OF TRANSIENT WELLBORE SIMULATOR TO EVALUATE DELIVERABILITY
Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE
Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent
International Journal of TechnoChem Research. Eldho Abraham
International Journal of TechnoChem Research ISSN: 2395-4248 www.technochemsai.com Vol.01, No.01, pp 25-34, 2015 Study on Gas Induction and Comparison of Power Consumption of Gas Inducing Mechanically
T 815 SUBJECT. (No changes from Draft 2)
WI 050308.03 T 815 DRAFT NO. 3 TAPPI DATE March 12, 2006 WORKING GROUP CHAIRMAN Gary Vosler SUBJECT CATEGORY RELATED METHODS FISCOTEC See Additional Information CAUTION: This Test Method may include safety
Plate waves in phononic crystals slabs
Acoustics 8 Paris Plate waves in phononic crystals slabs J.-J. Chen and B. Bonello CNRS and Paris VI University, INSP - 14 rue de Lourmel, 7515 Paris, France [email protected] 41 Acoustics 8 Paris We
John D. Dyson, Manager Municipal Water Group Infilco Degremont Inc. Richmond, VA
High Rate Pulsed Sludge Blanket Clarifier Performance on Rivers and Reservoirs with Widely Different Raw Water Characteristics in Texas and United States John D. Dyson, Manager Municipal Water Group Infilco
CHARACTERIZATION OF HIGH PRESSURE RTM PROCESSES FOR MANUFACTURING OF HIGH PERFORMANCE COMPOSITES
CHARACTERIZATION OF HIGH PRESSURE RTM PROCESSES FOR MANUFACTURING OF HIGH PERFORMANCE COMPOSITES R. Chaudhari 1*, M. Karcher 1, P. Elsner 1, F. Henning 1 1 Fraunhofer Institute for Chemical Technology,
EXTRUDER FEEDING SYSTEMS
EXTRUDER FEEDING SYSTEMS www.kreyenborg-pt.com www.kreyenborg-group.com KREYENBORG GROUP BEST TECHNOLOGY INSIDE! The KREYENBORG GROUP is comprised of the following companies: KREYENBORG GmbH, BKG Bruckmann
Energy savings in commercial refrigeration. Low pressure control
Energy savings in commercial refrigeration equipment : Low pressure control August 2011/White paper by Christophe Borlein AFF and l IIF-IIR member Make the most of your energy Summary Executive summary
Doppler Effect Plug-in in Music Production and Engineering
, pp.287-292 http://dx.doi.org/10.14257/ijmue.2014.9.8.26 Doppler Effect Plug-in in Music Production and Engineering Yoemun Yun Department of Applied Music, Chungwoon University San 29, Namjang-ri, Hongseong,
When Quality Control is not enough
When Quality Control is not enough What is Quality Control to you? Chasing Quality instead of Performance? Interested in the difference? Predictive Quality Control When Quality Control is not enough Quality
The Impact Of Cementing On Proper Well Control
The Impact Of Cementing On Proper Well Control Lee Dillenbeck Senior Advisor, Cementing Chevron ETC Drilling and Completions 2010 Chevron Learning Objectives Explain the main reasons for cementing wells
Numerical modelling of shear connection between concrete slab and sheeting deck
7th fib International PhD Symposium in Civil Engineering 2008 September 10-13, Universität Stuttgart, Germany Numerical modelling of shear connection between concrete slab and sheeting deck Noémi Seres
Soil Suction. Total Suction
Soil Suction Total Suction Total soil suction is defined in terms of the free energy or the relative vapor pressure (relative humidity) of the soil moisture. Ψ = v RT ln v w 0ω v u v 0 ( u ) u = partial
CORESTA RECOMMENDED METHOD Nº 81
CORESTA RECOMMENDED METHOD Nº 81 ROUTINE ANALYTICAL MACHINE FOR E-CIGARETTE AEROSOL GENERATION AND COLLECTION DEFINITIONS AND STANDARD CONDITIONS (June 2015) 0. INTRODUCTION This Method includes the requirements
USE OF GEOSYNTHETICS FOR FILTRATION AND DRAINAGE
USE OF GEOSYNTHETICS FOR FILTRATION AND DRAINAGE Prof. G L Sivakumar Babu Department of Civil Engineering Indian Institute of Science Bangalore 560012 Functions of a Filter Retain particles of the base
CASE STUDY. University of Windsor, Canada Modal Analysis and PULSE Reflex. Automotive Audio Systems PULSE Software including PULSE Reflex, Transducers
CASE STUDY University of Windsor, Canada Modal Analysis and PULSE Reflex Automotive Audio Systems PULSE Software including PULSE Reflex, Transducers The automotive glass subwoofer technology has been in
Abrasive-Flow Machining
1 Polishing Using Magnetic Fields Figure 25.30 Schematic illustration of polishing of balls and rollers using magnetic fields. (a) Magnetic float polishing of ceramic balls. (b) Magnetic-field-assisted
MONITORING THE GPR RESPONSE OF CURING CONCRETE T. De Souza 1, A.P. Annan 1, J.D. Redman 1, and N. Hu 1 1 Sensors & Software Inc., Mississauga, Canada
MONITORING THE GPR RESPONSE OF CURING CONCRETE T. De Souza 1, A.P. Annan 1, J.D. Redman 1, and N. Hu 1 1 Sensors & Software Inc., Mississauga, Canada Abstract: Ground penetrating radar (GPR) is becoming
INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!
In-situ Testing! Insitu Testing! Insitu testing is used for two reasons:! To allow the determination of shear strength or penetration resistance or permeability of soils that would be difficult or impossible
Plastics and Polymer Business. Properties enhancement for Plastics
News Letter Vol. 18, issue October-December, 2012 Hyperdispersants and Coupling Agents for Thermoplastics and Thermosets Solplus, Ircolplus and Solsperse hyperdispersants and coupling agents have been
Chapter 3.5: Fans and Blowers
Part I: Objective type questions and answers Chapter 3.5: Fans and Blowers 1. The parameter used by ASME to define fans, blowers and compressors is a) Fan ration b) Specific ratio c) Blade ratio d) Twist
EXPERIMENTAL RESEARCH ON CHARACTERISTICS OF CENTRIFUGAL PUMP NOISE IN WATER PIPE SYS- TEM
The 21 st International Congress on Sound and Vibration 13-17 July, 2014, Beijing/China EXPERIMENTAL RESEARCH ON CHARACTERISTICS OF CENTRIFUGAL PUMP NOISE IN WATER PIPE SYS- TEM Muze Huang, Hongling Sun,
NUMERICAL INVESTIGATIONS ON HEAT TRANSFER IN FALLING FILMS AROUND TURBULENCE WIRES
NUMERICAL INVESTIGATIONS ON HEAT TRANSFER IN FALLING FILMS AROUND TURBULENCE WIRES Abstract H. Raach and S. Somasundaram Thermal Process Engineering, University of Paderborn, Paderborn, Germany Turbulence
ENS 07 Paris, France, 3-4 December 2007
ENS 7 Paris, France, 3-4 December 7 FRICTION DRIVE SIMULATION OF A SURFACE ACOUSTIC WAVE MOTOR BY NANO VIBRATION Minoru Kuribayashi Kurosawa, Takashi Shigematsu Tokyou Institute of Technology, Yokohama
BRAZED PLATE INSTALLATION MANUAL
www.brazedplate.com BRAZED PLATE INSTALLATION MANUAL S.E.C. Heat Exchangers P.E.I. CANADA C0A 1A0 tel; 902-659-2424 fax; 902-659-2800 Table of Contents Description...2 Mounting position...3 Piping connections......3
Encoders for Linear Motors in the Electronics Industry
Technical Information Encoders for Linear Motors in the Electronics Industry The semiconductor industry and automation technology increasingly require more precise and faster machines in order to satisfy
Adhesive Recommendation for Altro Flooring. Porous (absorbent) subfloors (most wood subfloors and some concrete)
Adhesive Recommendation for Altro Flooring Product Safety Sheet Flooring Smooth Sheet Flooring Porous (absorbent) subfloors (most wood subfloors and some concrete) Altrofix 30/31 (excessively heavy rolling
Chemical Engineering - CHEN
Auburn University 1 Chemical Engineering - CHEN Courses CHEN 2100 PRINCIPLES OF CHEMICAL ENGINEERING (4) LEC. 3. LAB. 3. Pr. (CHEM 1110 or CHEM 1117 or CHEM 1030) and (MATH 1610 or MATH 1613 or MATH 1617
Measurement and correction of baggy edges on paper machines
Measurement and correction of baggy edges on paper machines Frédéric Parent and Jean Hamel FPInnovations, 57 Boul. St-Jean, Pointe-Claire, QC, Canada, H9R 3J9 ABSTRACT A new tension beam was developed
Experimental Study on Non Destructive Testing Techniques (NDTT)
Experimental Study on Non Destructive Testing Techniques (NDTT) G.Lalitha 1, K.Bala Showry 2 1 G.Lalitha Assistant Prof, Civil Engineering, BVRIT, TS, India 2 Dr.K.Bala Showry Professor, Mechanical Engineering,
FXA 2008. UNIT G485 Module 4 5.4.3 Ultrasound. Candidates should be able to :
1 Candidates should be able to : ULTRASOUND Describe the properties of ultrasound. ULTRASOUND is any sound wave having a frequency greater than the upper frequency limit of human hearing (20 khz). Describe
