INTERNATIONAL STANDARD
|
|
|
- Clementine Johnston
- 10 years ago
- Views:
Transcription
1 INTERNATIONAL STANDARD IEC Second edition Information technology equipment Safety Part 1: General requirements IEC 2005 Copyright - all rights reserved No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland Telephone: Telefax: [email protected] Web: Commission Electrotechnique Internationale International Electrotechnical Commission Международная Электротехническая Комиссия PRICE CODE For price, see current catalogue XM
2 IEC: CONTENTS FOREWORD...15 INTRODUCTION Principles of safety General principles of safety Hazards Materials and components General Scope Definitions General requirements General conditions for tests Components Power interface Markings and instructions Protection from hazards Protection from electric shock and energy hazards SELV circuits TNV circuits Limited current circuits Limited power sources Provisions for earthing and bonding Overcurrent and earth fault protection in primary circuits Safety interlocks Electrical insulation Clearances, creepage distances and distances through insulation Wiring, connections and supply General Connection to a mains supply Wiring terminals for connection of external conductors Disconnection from the mains supply Interconnection of equipment Physical requirements Stability Mechanical strength Design and construction Protection against hazardous moving parts Thermal requirements Openings in enclosures Resistance to fire Electrical requirements and simulated abnormal conditions Touch current and protective conductor current Electric strength Abnormal operating and fault conditions...375
3 IEC: Connection to telecommunication networks Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment Protection of equipment users from overvoltages on telecommunication networks Protection of the telecommunication wiring system from overheating Connection to cable distribution systems General Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment Protection of equipment users from overvoltages on the cable distribution system Insulation between primary circuits and cable distribution systems Annex A (normative) Tests for resistance to heat and fire Annex B (normative) Motor tests under abnormal conditions Annex C (normative) Transformers Annex D (normative) Measuring instruments for touch current tests Annex E (normative) Temperature rise of a winding Annex F (normative) Measurement of clearances and creepage distances Annex G (normative) Alternative method for determining minimum clearances Annex H (normative) Ionizing radiation Annex J (normative) Table of electrochemical potentials (see ) Annex K (normative) Thermal controls Annex L (normative) Normal load conditions for some types of electrical business equipment Annex M (normative) Criteria for telephone ringing signals Annex N (normative) Impulse test generators Annex P (normative) Normative references Annex Q (normative) Voltage dependent resistors (VDRs) Annex R (informative) Examples of requirements for quality control programmes Annex S (informative) Procedure for impulse testing Annex T (informative) Guidance on protection against ingress of water Annex U (normative) Insulated winding wires for use without interleaved insulation Annex V (normative) AC power distribution systems Annex W (informative) Summation of touch currents Annex X (informative) Maximum heating effect in transformer tests Annex Y (normative) Ultraviolet light conditioning test Annex Z (informative) Overvoltage categories (see and Clause G.2) Annex AA (normative) Mandrel test (see ) Annex BB (informative) Changes in the second edition...557
4 IEC: Bibliography Index Figure 2A Test finger Figure 2B Test pin Figure 2C Test probe Figure 2D - Accessibility of internal conductive parts Figure 2E Voltages in SELV circuits under single fault conditions Figure 2F Maximum voltages permitted after a single fault Figure 2G Test generator Figure 2H Examples of application of insulation Figure 2J Thermal ageing time Figure 2K Abrasion resistance test for coating layers Figure 4A Impact test using a steel ball Figure 4B Examples of cross-sections of designs of openings preventing vertical access Figure 4C Examples of louvre design Figure 4D Enclosure openings Figure 4E Typical bottom of a fire enclosure for partially enclosed component or assembly Figure 4F Baffle plate construction Figure 5A Test circuit for touch current of single-phase equipment on a star TN or TT power supply system Figure 5B Test circuit for touch current of three-phase equipment on a star TN or TT power supply system Figure 6A Test for separation between a telecommunication network and earth Figure 6B Application points of test voltage Figure B.1 Determination of arithmetic average temperature Figure C.1 Determination of arithmetic average temperature Figure D.1 Measuring instrument Figure D.2 Alternative measuring instrument Figure F.1 Narrow groove Figure F.2 Wide groove Figure F.3 V-shaped groove Figure F.4 Rib Figure F.5 Uncemented joint with narrow groove Figure F.6 Uncemented joint with wide groove Figure F.7 Uncemented joint with narrow and wide grooves Figure F.8 Narrow recess Figure F.9 Wide recess Figure F.10 Coating around terminals Figure F.11 Coating over printed wiring...443
5 IEC: Figure F.12 Measurements through openings in enclosures Figure F.13 Intervening, unconnected conductive part Figure F.14 Solid insulating material Figure F.15 Thin sheet insulating material Figure F.16 Cemented joints in multi-layer printed board Figure F.17 Component filled with insulating compound Figure F.18 Partitioned bobbin Figure M.1 Definition of ringing period and cadence cycle Figure M.2 I TS1 limit curve for cadenced ringing signal Figure M.3 Peak and peak-to-peak currents Figure M.4 Ringing voltage trip criteria Figure N.1 ITU-T impulse test generator circuit Figure N.2 IEC impulse test generator circuit Figure S.1 Waveform on insulation without surge suppressors and no breakdown Figure S.2 Waveforms on insulation during breakdown without surge suppressors Figure S.3 Waveforms on insulation with surge suppressors in operation Figure S.4 Waveform on short-circuited surge suppressor and insulation Figure V.1 Examples of TN-S power distribution systems Figure V.2 Example of TN-C-S power distribution system Figure V.3 Example of TN-C power distribution system Figure V.4 Example of single-phase, three-wire TN-C power distribution system Figure V.5 Example of three line and neutral TT power distribution system Figure V.6 Example of three line TT power distribution system Figure V.7 Example of three line (and neutral) IT power distribution system Figure V.8 Example of three line IT power distribution system Figure W.1 Touch current from a floating circuit Figure W.2 Touch current from an earthed circuit Figure W.3 Summation of touch currents in a PABX Figure AA.1 Mandrel Figure AA.2 Initial position of mandrel Figure AA.3 Final position of mandrel Table 1A Voltage ranges of SELV and TNV circuits...51 Table 1B Equivalence of flammability classes...59 Table 1C Capacitor ratings according to IEC Table 1D Informative examples of application of capacitors...85 Table 2A Distance through insulation of internal wiring Table 2B Limits for power sources without an overcurrent protective device Table 2C Limits for power sources with an overcurrent protective device...147
6 IEC: Table 2D Minimum size of protective bonding conductors Table 2E Test duration, a.c. mains supplies Table 2F Informative examples of protective devices in single-phase equipment or subassemblies Table 2G Informative examples of protective devices in three-phase equipment Table 2H Examples of application of insulation Table 2J AC mains transient voltages Table 2K Minimum clearances for insulation in primary circuits and between primary and secondary circuits Table 2L Additional clearances in primary circuits Table 2M Minimum clearances in secondary circuits Table 2N Minimum creepage distances Table 2P Tests for insulation in non-separable layers Table 2Q Minimum separation distances for coated printed boards Table 2R Insulation in printed boards Table 3A Sizes of cables and conduits for equipment having a rated current not exceeding 16 A Table 3B Sizes of conductors Table 3C Physical tests on power supply cords Table 3D Range of conductor sizes to be accepted by terminals Table 3E Sizes of terminals for mains supply conductors and protective earthing conductors Table 4A Minimum property retention limits after UV exposure Table 4B Temperature limits, materials and components Table 4C Touch temperature limits Table 4D Size and spacing of openings in metal bottoms of fire enclosures Table 4E Summary of material flammability requirements Table 5A Maximum current Table 5B Test voltages for electric strength tests based on peak working voltages Part Table 5B Test voltages for electric strength tests based on peak working voltages Part Table 5C Test voltages for electric strength tests based on required withstand voltages.375 Table 5D Temperature limits for overload conditions Table B.1 Temperature limits for motor windings (except for running overload test) Table B.2 Permitted temperature limits for running overload tests Table C.1 Temperature limits for transformer windings Table F.1 Value of X Table G.1 AC mains transient voltages...453
7 IEC: Table G.2 Minimum clearances up to m above sea level Table J.1 Electrochemical potentials (V) Table N.1 Component values for Figures N.1 and N Table R.1 Rules for sampling and inspection coated printed boards Table R.2 Rules for sampling and inspection reduced clearances Table T.1 Extract from IEC Table U.1 Mandrel diameter Table U.2 Oven temperature Table X.1 Test steps Table Z.1 Overvoltage categories...549
8 IEC: INTERNATIONAL ELECTROTECHNICAL COMMISSION INFORMATION TECHNOLOGY EQUIPMENT SAFETY Part 1: General requirements FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as IEC Publication(s) ). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and nongovernmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC has been prepared by IEC technical committee 108: Safety of electronic equipment within the field of audio/video, information technology and communication technology. This second edition of IEC cancels and replaces the first edition of IEC , issued in 2001, and constitutes a technical revision. The principal changes in this edition as compared with the first edition of IEC are given in Annex BB, including a list of changed subclause, table and figure numbers.
9 IEC: The text of this standard is based on the following documents: FDIS 108/135A/FDIS Report on voting 108/147/RVD Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. IEC includes the basic requirements for the safety of information technology equipment. Additional parts of IEC will cover specific safety requirements for information technology equipment having limited applications or having special features as follows: Part 21: Remote feeding (published); Part 22: Equipment installed outdoors (planned); Part 23: Large data storage equipment (planned); Except for notes, all text within a normative figure, or in a box under a normative table, is also normative. Text with a superscript reference is linked to a particular item in the table. Other text in a box under a table applies to the whole table. Informative annexes and text beginning with the word "NOTE" are not normative. They are provided only to give additional information. "Country" notes are also informative but call attention to requirements that are normative in those countries. In this standard, the following print types are used: Requirements proper and normative annexes: roman type. Compliance statements and test specifications: italic type. Notes in the text and in tables: smaller roman type. Terms that are defined in 1.2: SMALL CAPITALS. The committee has decided that the contents of this publication will remain unchanged until the maintenance result date indicated on the IEC web site under " in the data related to the specific publication. At this date, the publication will be reconfirmed; withdrawn; replaced by a revised edition, or amended.
10 IEC: INTRODUCTION 0 Principles of safety The following principles have been adopted by technical committee 108 in the development of this standard. These principles do not cover performance or functional characteristics of equipment. Words printed in SMALL CAPITALS are terms that are defined in 1.2 of this standard. 0.1 General principles of safety It is essential that designers understand the underlying principles of safety requirements in order that they can engineer safe equipment. These principles are not an alternative to the detailed requirements of this standard, but are intended to provide designers with an appreciation of the basis of these requirements. Where the equipment involves technologies and materials or methods of construction not specifically covered, the design of the equipment should provide a level of safety not less than those described in these principles of safety. Designers shall take into account not only normal operating conditions of the equipment but also likely fault conditions, consequential faults, foreseeable misuse and external influences such as temperature, altitude, pollution, moisture, overvoltages on the MAINS SUPPLY and overvoltages on a TELECOMMUNICATION NETWORK or a CABLE DISTRIBUTION SYSTEM. Dimensioning of insulation spacings should take account of possible reductions by manufacturing tolerances, or where deformation could occur due to handling, shock and vibration likely to be encountered during manufacture, transport and normal use. The following priorities should be observed in determining what design measures to adopt: where possible, specify design criteria that will eliminate, reduce or guard against hazards; where the above is not practicable because the functioning of the equipment would be impaired, specify the use of protective means independent of the equipment, such as personal protective equipment (which is not specified in this standard); where neither of the above measures is practicable, or in addition to those measures, specify the provision of markings and instructions regarding the residual risks. There are two types of persons whose safety needs to be considered, USERS (or OPERATORS) and SERVICE PERSONS. USER is the term applied to all persons other than SERVICE PERSONS. Requirements for protection should assume that USERS are not trained to identify hazards, but will not intentionally create a hazardous situation. Consequently, the requirements will provide protection for cleaners and casual visitors as well as the assigned USERS. In general, USERS
11 IEC: should not have access to hazardous parts, and to this end, such parts should only be in SERVICE ACCESS AREAS or in equipment located in RESTRICTED ACCESS LOCATIONS. When USERS are admitted to RESTRICTED ACCESS LOCATIONS they shall be suitably instructed. SERVICE PERSONS are expected to use their training and skill to avoid possible injury to themselves and others due to obvious hazards that exist in SERVICE ACCESS AREAS of the equipment or on equipment located in RESTRICTED ACCESS LOCATIONS. However, SERVICE PERSONS should be protected against unexpected hazards. This can be done by, for example, locating parts that need to be accessible for servicing away from electrical and mechanical hazards, providing shields to avoid accidental contact with hazardous parts, and providing labels or instructions to warn personnel about any residual risk. Information about potential hazards can be marked on the equipment or provided with the equipment, depending on the likelihood and severity of injury, or made available for SERVICE PERSONS. In general, USERS shall not be exposed to hazards likely to cause injury, and information provided for USERS should primarily aim at avoiding misuse and situations likely to create hazards, such as connection to the wrong power source and replacement of fuses by incorrect types. MOVABLE EQUIPMENT is considered to present a slightly increased risk of shock, due to possible extra strain on the supply cord leading to rupture of the earthing conductor. With HAND-HELD EQUIPMENT, this risk is increased; wear on the cord is more likely, and further hazards could arise if the units were dropped. TRANSPORTABLE EQUIPMENT introduces a further factor because it can be used and carried in any orientation; if a small metallic object enters an opening in the ENCLOSURE it can move around inside the equipment, possibly creating a hazard. 0.2 Hazards Application of a safety standard is intended to reduce the risk of injury or damage due to the following: electric shock; energy related hazards; fire; heat related hazards; mechanical hazards; radiation; chemical hazards.
12 IEC: Electric shock Electric shock is due to current passing through the human body. The resulting physiological effects depend on the value and duration of the current and the path it takes through the body. The value of the current depends on the applied voltage, the impedance of the source and the impedance of the body. The body impedance depends in turn on the area of contact, moisture in the area of contact and the applied voltage and frequency. Currents of approximately half a milliampere can cause a reaction in persons in good health and may cause injury indirectly due to involuntary reaction. Higher currents can have more direct effects, such as burn or muscle tetanization leading to inability to let go or to ventricular fibrillation. Steady state voltages up to 42,4 V peak, or 60 V d.c., are not generally regarded as hazardous under dry conditions for an area of contact equivalent to a human hand. Bare parts that have to be touched or handled should be at earth potential or properly insulated. Some equipment will be connected to telephone and other external networks. Some TELECOMMUNICATION NETWORKS operate with signals such as voice and ringing superimposed on a steady d.c. supply voltage; the total may exceed the values given above for steady-state voltages. It is common practice for the SERVICE PERSONS of telephone companies to handle parts of such circuits bare-handed. This has not caused serious injury, because of the use of cadenced ringing and because there are limited areas of contact with bare conductors normally handled by SERVICE PERSONS. However, the area of contact of a part accessible to the USER, and the likelihood of the part being touched, should be further limited (for example, by the shape and location of the part). It is normal to provide two levels of protection for USERS to prevent electric shock. Therefore, the operation of equipment under normal conditions and after a single fault, including any consequential faults, should not create a shock hazard. However, provision of additional protective measures, such as protective earthing or SUPPLEMENTARY INSULATION, is not considered a substitute for, or a relief from, properly designed BASIC INSULATION. Harm may result from: Contact with bare parts normally at HAZARDOUS VOLTAGES. Breakdown of insulation between parts normally at HAZARDOUS VOLTAGES and accessible conductive parts. Examples of measures to reduce risks: Prevent USER access to parts at HAZARDOUS VOLTAGES by fixed or locked covers, SAFETY INTERLOCKS, etc. Discharge accessible capacitors that are at HAZARDOUS VOLTAGES. Provide BASIC INSULATION and connect the accessible conductive parts and circuits to earth so that exposure to the voltage which can develop is limited because overcurrent protection will disconnect the parts having low impedance faults within a specified time; or provide a metal screen connected to protective earth between the parts, or provide DOUBLE INSULATION or REINFORCED INSULATION between the parts, so that breakdown to the accessible part is not likely to occur.
13 IEC: Contact with circuits connected to TELECOMMUNICATION NETWORKS that exceed 42,4 V peak or 60 V d.c. Breakdown of USER-accessible insulation. TOUCH CURRENT (leakage current) flowing from parts at HAZARDOUS VOLTAGES to accessible parts, or failure of a protective earthing connection. TOUCH CURRENT may include current due to EMC filter components connected between PRIMARY CIRCUITS and accessible parts. Limit the accessibility and area of contact of such circuits, and separate them from unearthed parts to which access is not limited. Insulation that is accessible to the USER should have adequate mechanical and electrical strength to reduce the likelihood of contact with HAZARDOUS VOLTAGES. Limit TOUCH CURRENT to a specified value, or provide a high integrity protective earthing connection Energy related hazards Injury or fire may result from a short-circuit between adjacent poles of high current supplies or high capacitance circuits, causing: burns; arcing; ejection of molten metal. Even circuits whose voltages are safe to touch may be hazardous in this respect. Examples of measures to reduce risks include: separation; shielding; provision of SAFETY INTERLOCKS Fire Risk of fire may result from excessive temperatures either under normal operating conditions or due to overload, component failure, insulation breakdown or loose connections. Fires originating within the equipment should not spread beyond the immediate vicinity of the source of the fire, nor cause damage to the surroundings of the equipment. Examples of measures to reduce risks include: providing overcurrent protection; using constructional materials having appropriate flammability properties for their purpose; selection of parts, components and consumable materials to avoid high temperature which might cause ignition; limiting the quantity of combustible materials used;
14 IEC: This is a preview - click here to buy the full publication shielding or separating combustible materials from likely ignition sources; using ENCLOSURES or barriers to limit the spread of fire within the equipment; using suitable materials for ENCLOSURES so as to reduce the likelihood of fire spreading from the equipment Heat related hazards Injury may result from high temperatures under normal operating conditions, causing: burns due to contact with hot accessible parts; degradation of insulation and of safety-critical components; ignition of flammable liquids. Examples of measures to reduce risks include: taking steps to avoid high temperature of accessible parts; avoiding temperatures above the ignition point of liquids; provision of markings to warn USERS where access to hot parts is unavoidable Mechanical hazards Injury may result from: sharp edges and corners; moving parts that have the potential to cause injury; equipment instability; flying particles from imploding cathode ray tubes and exploding high pressure lamps. Examples of measures to reduce risks include: rounding of sharp edges and corners; guarding; provision of SAFETY INTERLOCKS; providing sufficient stability to free-standing equipment; selecting cathode ray tubes and high pressure lamps that are resistant to implosion and explosion respectively; provision of markings to warn USERS where access is unavoidable.
15 IEC: Radiation Injury to USERS and to SERVICE PERSONS may result from some forms of radiation emitted by equipment. Examples are sonic (acoustic), radio frequency, infra-red, ultraviolet and ionizing radiation, and high intensity visible and coherent light (lasers). Examples of measures to reduce risks include: limiting the energy level of potential radiation sources; screening radiation sources; provision of SAFETY INTERLOCKS; provision of markings to warn USERS where exposure to the radiation hazard is unavoidable Chemical hazards Injury may result from contact with some chemicals or from inhalation of their vapours and fumes. Examples of measures to reduce risks include: avoiding the use of constructional and consumable materials likely to cause injury by contact or inhalation during intended and normal conditions of use; avoiding conditions likely to cause leakage or vaporization; provision of markings to warn USERS about the hazards. 0.3 Materials and components Materials and components used in the construction of equipment should be so selected and arranged that they can be expected to perform in a reliable manner for the anticipated life of the equipment without creating a hazard, and would not contribute significantly to the development of a serious fire hazard. Components should be selected so that they remain within their manufacturers' ratings under normal operating conditions, and do not create a hazard under fault conditions.
16 IEC: INFORMATION TECHNOLOGY EQUIPMENT SAFETY Part 1: General requirements 1 General 1.1 Scope Equipment covered by this standard This standard is applicable to mains-powered or battery-powered information technology equipment, including electrical business equipment and associated equipment, with a RATED VOLTAGE not exceeding 600 V. This standard is also applicable to such information technology equipment: designed for use as telecommunication terminal equipment and TELECOMMUNICATION NETWORK infrastructure equipment, regardless of the source of power; designed and intended to be connected directly to, or used as infrastructure equipment in, a CABLE DISTRIBUTION SYSTEM, regardless of the source of power; designed to use the AC MAINS SUPPLY as a communication transmission medium (see Clause 6, Note 4 and 7.1, Note 4). This standard is also applicable to components and subassemblies intended for incorporation in information technology equipment. It is not expected that such components and subassemblies comply with every aspect of the standard, provided that the complete information technology equipment, incorporating such components and subassemblies, does comply. NOTE 1 Examples of aspects with which uninstalled components and subassemblies may not comply include the marking of the power rating and access to hazardous parts. NOTE 2 This standard may be applied to the electronic parts of equipment even if that equipment does not wholly fall within its Scope, such as large-scale air conditioning systems, fire detection systems and fire extinguishing systems. Different requirements may be necessary for some applications. This standard specifies requirements intended to reduce risks of fire, electric shock or injury for the OPERATOR and layman who may come into contact with the equipment and, where specifically stated, for a SERVICE PERSON. This standard is intended to reduce such risks with respect to installed equipment, whether it consists of a system of interconnected units or independent units, subject to installing, operating and maintaining the equipment in the manner prescribed by the manufacturer.
17 IEC: Examples of equipment that is in the scope of this standard are: Generic product type banking equipment data and text processing machines and associated equipment data network equipment electrical and electronic retail equipment electrical and electronic office machines other information technology equipment postage equipment telecommunication network infrastructure equipment telecommunication terminal equipment Specific example of generic type monetary processing machines including automated teller (cash dispensing) machines (ATM) data preparation equipment, data processing equipment, data storage equipment, personal computers, plotters, printers, scanners, text processing equipment, visual display units bridges, data circuit terminating equipment, data terminal equipment, routers cash registers, point of sale terminals including associated electronic scales calculators, copying machines, dictation equipment, document shredding machines, duplicators, erasers, micrographic office equipment, motor-operated files, paper trimmers (punchers, cutting machines, separators), paper jogging machines, pencil sharpeners, staplers, typewriters photoprinting equipment, public information terminals, multimedia equipment mail processing machines, postage machines billing equipment, multiplexers, network powering equipment, network terminating equipment, radio basestations, repeaters, transmission equipment, telecommunication switching equipment facsimile equipment, key telephone systems, modems, PABXs, pagers, telephone answering machines, telephone sets (wired and wireless) NOTE 3 The requirements of IEC may also be used to meet safety requirements for multimedia equipment. See IEC Guide 112, Guide on the safety of multimedia equipment. This list is not intended to be comprehensive, and equipment that is not listed is not necessarily excluded from the Scope. Equipment complying with the relevant requirements in this standard is considered suitable for use with process control equipment, automatic test equipment and similar systems requiring information processing facilities. However, this standard does not include requirements for performance or functional characteristics of equipment Additional requirements Requirements additional to those specified in this standard may be necessary for: equipment intended for operation in special environments (for example, extremes of temperature; excessive dust, moisture or vibration; flammable gases; and corrosive or explosive atmospheres); electromedical applications with physical connections to the patient; equipment intended to be used in vehicles, on board ships or aircraft, in tropical countries, or at altitudes greater than m; equipment intended for use where ingress of water is possible; for guidance on such requirements and on relevant testing, see Annex T. NOTE Attention is drawn to the fact that authorities of some countries impose additional requirements.
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60076-11 First edition 2004-05 Power transformers Part 11: Dry-type transformers This English-language version is derived from the original bilingual publication by leaving out
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61215 Second edition 2005-04 Crystalline silicon terrestrial photovoltaic (PV) modules Design qualification and type approval This English-language version is derived from the
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61892-1 First edition 2001-12 Mobile and fixed offshore units Electrical installations Part 1: General requirements and conditions Unités fixes et mobiles en mer Installations
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60812 Second edition 2006-01 Analysis techniques for system reliability Procedure for failure mode and effects analysis (FMEA) This English-language version is derived from the
TECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION IEC TS 61400-14 First edition 2005-03 Wind turbines Part 14: Declaration of apparent sound power level and tonality values IEC 2005 Copyright - all rights reserved No part of this
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61400-2 Second edition 2006-03 Wind turbines Part 2: Design requirements for small wind turbines This English-language version is derived from the original bilingual publication
INTERNATIONAL STANDARD
IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60227-1 Edition 2.2 1998-03 Edition 2:1993 consolidated with amendments 1:1995 and 2:1997 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60870-5-103 First edition 1997-12 Telecontrol equipment and systems Part 5-103: Transmission protocols Companion standard for the informative interface of protection equipment
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60071-2 Third edition 1996-12 Insulation co-ordination Part 2: Application guide This English-language version is derived from the original bilingual publication by leaving out
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60300-3-3 Second edition 2004-07 Dependability management Part 3-3: Application guide Life cycle costing IEC 2004 Copyright - all rights reserved No part of this publication
Guide to the electrical parameter classifications of IEC 60950 and IEC 62368 safety standards
Guide to the electrical parameter classifications of IEC 60950 and IEC 62368 safety standards Abstract This Guide is an informative listing of selected terms and definitions found in IEC Glossary entry
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60076-1 Edition 2.1 2000-04 Edition 2:1993 consolidated with amendment 1:1999 Power transformers Part 1: General This English-language version is derived from the original bilingual
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61190-1-3 Second edition 2007-04 Attachment materials for electronic assembly Part 1-3: Requirements for electronic grade solder alloys and fluxed and non-fluxed solid solders
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 62885-3 Edition 1.0 2014-12 colour inside Surface cleaning appliances Part 3: Wet carpet cleaning appliances Methods for measuring the performance INTERNATIONAL ELECTROTECHNICAL
ANSI/IEC 60529-2004. Degrees of Protection Provided by Enclosures (IP Code) (identical national adoption)
ANSI Approval Date November 3, 2004 ANSI/IEC 60529-2004 Degrees of Protection Provided by Enclosures (IP Code) (identical national adoption) Published by: National Electrical Manufacturers Association
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 62056-21 First edition 2002-05 Electricity metering Data exchange for meter reading, tariff and load control Part 21: Direct local data exchange This English-language version
Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD)
Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Note: This guidance document is a translation of official Chinese document which is issued by CQC (China Quality Certification Center) on
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61400-1 Second edition 1999-02 Wind turbine generator systems Part 1: Safety requirements Aérogénérateurs Partie 1: Spécifications de sécurité IEC 1999 Copyright - all rights
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61131-1 Second edition 2003-05 Programmable controllers Part 1: General information Automates programmables Partie 1: Informations générales IEC 2003 Copyright - all rights reserved
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61156-5 First edition 2002-03 Multicore and symmetrical pair/quad cables for digital communications Part 5: Symmetrical pair/quad cables with transmission characteristics up
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 62616 Edition 1.0 2010-02 Maritime navigation and radiocommunication equipment and systems Bridge navigational watch alarm system (BNWAS) INTERNATIONAL ELECTROTECHNICAL COMMISSION
CONSOLIDATED VERSION IEC 62304. Medical device software Software life cycle processes. colour inside. Edition 1.1 2015-06
IEC 62304 CONSOLIDATED VERSION Edition 1.1 2015-06 colour inside Medical device software life cycle processes INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 11.040 ISBN 978-2-8322-2765-7 Warning! Make sure
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 62305-3 Edition 2.0 2010-12 colour inside Protection against lightning Part 3: Physical damage to structures and life hazard INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE
NEMA ICS 61131-1-2005 (R2013) Programmable Controllers Part 1: General Information
NEMA ICS 61131-1-2005 (R2013) IEC Publication 61131-1 Programmable Controllers Part 1: General Information Published by: National Electrical Manufacturers Association 1300 North 17 th Street, Suite 900
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
TECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION IEC/TS 62351-7 Edition 1.0 2010-07 colour inside Power systems management and associated information exchange Data and communications security Part 7: Network and system management
TECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION IEC/TS 62443-1-1 Edition 1.0 2009-07 colour inside Industrial communication networks Network and system security Part 1-1: Terminology, concepts and models INTERNATIONAL ELECTROTECHNICAL
Installation and safety instructions for AC/DC built-in devices
The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further
This is a preview - click here to buy the full publication TECHNICAL REPORT
TECHNICAL REPORT IEC TR 62066 First edition 2002-06 Surge overvoltages and surge protection in low-voltage a.c. power systems General basic information Surtensions de choc et protection contre la foudre
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61968-8 Edition 1.0 2015-05 colour inside Application integration at electric utilities System interfaces for distribution management Part 8: Interfaces for customer operations
INTERNATIONAL STANDARD
ISO/IEC 14543-4-2 INTERNATIONAL STANDARD Edition 1.0 2008-05 Information technology Home electronic system (HES) architecture Part 4-2: Communication layers Transport, network and general parts of data
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60297-5-101 First edition 2001-01 Mechanical structures for electronic equipment Dimensions of mechanical structures of the 482,6 mm (19 in) series Part 5-101: Subracks and associated
GUIDE TO THE MAINTENANCE, INSPECTION AND TESTING OF PORTABLE EQUIPMENT (ELECTRICAL APPLIANCES AND TOOLS) IN THE WORKPLACE
GUIDE TO THE MAINTENANCE, INSPECTION AND TESTING OF PORTABLE EQUIPMENT (ELECTRICAL APPLIANCES AND TOOLS) IN THE WORKPLACE ET 215:2008 ELECTRO-TECHNICAL COUNCIL OF IRELAND 2008 Page 1 of 6 Published by
Model 1756 Test Lead Kit
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 1756 Test Lead Kit Gerneral Purpose Test Lead Information Description These test leads allow you
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
Trade of Electrician. Three-phase Distribution Boards And Socket Circuits
Trade of Electrician Standards Based Apprenticeship Three-phase Distribution Boards And Socket Circuits Phase 2 Module No. 2.3 Unit No. 2.3.2 COURSE NOTES Created by Charlie Walsh - Athlone TC Revision
NEMA ICS 61131-4-2005 (R2013) Programmable Controllers Part 4: User Guidelines
NEMA ICS 61131-4-2005 (R2013) IEC Publication 61131-4 Programmable Controllers Part 4: User Guidelines Published by: National Electrical Manufacturers Association 1300 North 17 th Street, Suite 900 Rosslyn,
This is a preview - click here to buy the full publication TECHNICAL REPORT
TECHNICAL REPORT IEC TR 62380 First edition 2004-08 Reliability data handbook Universal model for reliability prediction of electronics components, PCBs and equipment : IEC 2004 Copyright - all rights
Disclosure to Promote the Right To Information
इ टरन ट म नक Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information
Safety of electronic equipment
Standard ECMA-287 2 nd edition - December 2002 International Standardizing Information and Communication Systems Safety of electronic equipment Phone: +41 22 849.60.00 - Fax: +41 22 849.60.01 - URL: http://www.ecma.ch
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61587-2 First edition 2000-12 Mechanical structures for electronic equipment Tests for IEC 60917 and IEC 60297 Part 2: Seismic tests for cabinets and racks Structures mécaniques
ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU
ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU George CURCANU, Constantin ILINCA, Ilie SBORA ICMET Craiova, Romania, Calea Bucuresti 144, phone:
This is a preview - click here to buy the full publication
IEC/TR 80001-2-3 TECHNICAL REPORT Edition 1.0 2012-07 colour inside Application of risk management for IT-networks incorporating medical devices Part 2-3: Guidance for wireless networks INTERNATIONAL ELECTROTECHNICAL
Electrical Resistance Resistance (R)
Electrical Resistance Resistance (R) Any device in a circuit which converts electrical energy into some other form impedes the current. The device which converts electrical energy to heat energy is termed
This is a preview - click here to buy the full publication
TECHNICAL REPORT IEC/TR 62443-3-1 Edition 1.0 2009-07 colour inside Industrial communication networks Network and system security Part 3 1: Security technologies for industrial automation and control systems
FAQs-Main switchboard design criteria
FAQs-Main switchboard design criteria Q: What is the Australian standard for main switchboards? Current Australian standard is AS/NZS 3439.1: 2002 originating from IEC 60439. The new series of standard
SURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
PROTECTION AGAINST ELECTRIC SHOCK by John Ware
16 become live under fault conditions. The potential of the metal enclosure is higher than that of the main earthing terminal of the installation (and that of Earth) because of a potential difference created
PUBLICLY AVAILABLE SPECIFICATION PRE-STANDARD
IEC/PAS 62443-3 PUBLICLY AVAILABLE SPECIFICATION PRE-STANDARD Edition 1.0 2008-01 Security for industrial process measurement and control Network and system security INTERNATIONAL ELECTROTECHNICAL COMMISSION
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
TECHNICAL REPORT IEC TR 62443-2-3. Security for industrial automation and control systems Part 2-3: Patch management in the IACS environment
TECHNICAL REPORT IEC TR 62443-2-3 Edition 1.0 2015-06 colour inside Security for industrial automation and control systems Part 2-3: Patch management in the IACS environment INTERNATIONAL ELECTROTECHNICAL
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61131-2 Second edition 2003-02 Programmable controllers Part 2: Equipment requirements and tests Automates programmables Partie 2: Spécifications et essais des équipements IEC
What are the basic electrical safety issues and remedies in solar photovoltaic installations?
What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic
Fire Protection Notice No. 9 ELECTRICAL SAFETY
Fire Protection Notice No. 9 ELECTRICAL SAFETY Because electricity is one of the most controllable forms of energy it can also be one of the safest. But, as industry and commerce draw ever more heavily
Evaluating Water-Damaged Electrical Equipment
Evaluating Water-Damaged Electrical Equipment 1 USE OF THIS PUBLICATION This publication provides information on how to evaluate electrical equipment that has been exposed to water through flooding, fire
Guide to the Safety, Health and Welfare at Work (General Application) Regulations 2007. Part 3: Electricity
Guide to the Safety, Health and Welfare at Work (General Application) Regulations 2007 Part 3: Electricity 9 Guide to the Safety, Health and Welfare at Work (General Application) Regulations 2007 Part
COVER PAGE FOR TEST REPORT
Issue Date: 2007-01-31 Page 1 of 1 Report Reference # E137006-A19-CB-1 COVER PAGE FOR TEST REPORT Test Item Description: Model/Type Reference: DIN-Rail Switch Mode Power Supply XT40.KK1-XX and XT40.KK2-XX,
Electrical Grounding. Appendix C
Appendix C Electrical Grounding Low-Voltage Equipment Grounding The most frequently cited Office of Safety and Health Administration (OSHA) electrical violation is improper occupational grounding of equipment
3053 Electrical Safety Training Program Course Outline
3053 Electrical Safety Training Program Course Outline The following outline summarizes the major points of information presented in the program. The outline can be used to review the program before conducting
1 Introduction. 2 Hazards From Electricity
Risk Assessment Application to Electrical Rigs A guide to assist the Competent Named person who will verify the safety of rigs consisting mainly of electrical equipment. 1 Introduction Every employer shall
DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)
DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations) DETAILS OF THE CLEINT Client and address ADDRESS OF THE INSTALLATION Installation
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61131-2 Third edition 2007-07 Programmable controllers Part 2: Equipment requirements and tests Commission Electrotechnique Internationale International Electrotechnical Commission
Calculating Creepage and Clearance Early Avoids Design Problems Later Homi Ahmadi
Calculating Creepage and Clearance Early Avoids Design Problems Later Homi Ahmadi One of the most common errors uncovered by product safety engineers stems from manufacturers and designers failing to fully
Heading FACT SHEET. Overview. www.safeworkaustralia.gov.au
ELECTRICAL RISKS AT THE WORKPLACE Heading FACT SHEET Overview This fact sheet provides general guidance for persons conducting a business or undertaking (PCBUs) and workers on managing electrical risks
Are you aware. Outline
Electrical Safety of Medical Equipment Hasan Al-Nashash School of Engineering American University of Sharjah (AUS) 1 Are you aware Electrocutions are the 5th leading cause of accidental death in the U.S.
12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting
12 SOLAR PHOTOVOLTAIC POWER by John Ware IT IS PLANNED for BS 7671:2008 to include a new Section 712 providing additional requirements for safety applicable to solar photovoltaic (pv) power supply systems.
Product Safety Considerations for Insulation Coordination of Low- Voltage Equipment. Scott Aldous, Compliance Engineer
Product Safety Considerations for Insulation Coordination of Low- Voltage Equipment Scott Aldous, Compliance Engineer What is Insulation Coordination? From IEC 60664-1, Edition 1.2: So what does that mean
AIR-CONDITIONER SPLIT TYPE
FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,
IEEE802.3poep Study Group Revision of isolation requirements in IEEE802.3 clause 33.
IEEE802.3poep Study Group Revision of isolation requirements in IEEE802.3 clause 33. San Francisco, July 2005 Arkadiy Peker Powerdsine [email protected] Yair Darshan Powerdsine [email protected]
Evaluating Water-Damaged Electrical Equipment
Evaluating Water-Damaged Electrical Equipment 1 USE OF THIS PUBLICATION This publication provides information on how to evaluate electrical equipment that has been exposed to water through flooding, fire
Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited
Electrical Wiring Methods, Components and Equipment for General Use Approved for Public Release; Further Dissemination Unlimited At the completion of this unit you shall be able to: 1. Utilize section
Evaluating Water-Damaged Electrical Equipment
Evaluating Water-Damaged Electrical www.nema.org Evaluating Water-Damaged Electrical 1 USE OF THIS PUBLICATION This publication provides information on how to evaluate electrical equipment that has been
2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY
2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY Thomas P. McNamara, P.E. Manager, Development Engineering ABB Inc. Power Technologies Medium
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
DRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
A series of technology briefs spanning Tyco Electronics product portfolio
A series of technology briefs spanning Tyco Electronics product portfolio Coordinated Circuit Protection Schemes Help Prevent Overvoltage and Overcurrent Damage Through advances in materials science and
Model UT33A: OPERATING MANUAL Table of Contents (1)
Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter structure Functional Buttons LCD Display Measurement Operation
FINAL DRAFT INTERNATIONAL STANDARD
PROJECT IEC 61975 Edition 1.0 2010-05 FINAL DRAFT INTERNATIONAL STANDARD High-voltage direct current (HVDC) installations System tests INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 29.130.01; 31.080.01
Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012
Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012 CHANGE CONTROL RECORD: Version Date Action* Reason for Revision
Operating instructions
ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 [email protected] www.ebmpapst.com CONTENTS 1. SAFETY REGULATIONS AND S 1.1 Levels of hazard
This document is a preview generated by EVS
INTERNATIONAL STANDARD NORME INTERNATIONALE IEC 62313 Edition 1.0 2009-04 Railway applications Power supply and rolling stock Technical criteria for the coordination between power supply (substation) and
The following document contains information on Cypress products.
The following document contains information on Cypress products. HANDLING PRECAUTIONS 1. Handling Precautions Any semiconductor devices have inherently a certain rate of failure. The possibility of failure
ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST
Name of School: OPTIONAL INFORMATION Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST Guidelines: This checklist
IEC specifications for LV assembly switchboards
Technical set IEC specifications for LV assembly switchboards In conformity with IEC 61439-1&2 standard Specifier Guide Introduction Within the IEC 61439 series of standards for low-voltage switchgear
A Practical Guide to Dielectric Testing
Chroma Systems Solutions, Inc. A Practical Guide to Dielectric Testing 19032 Series Electrical Safety Analyzer & 19050 Series Hipot Tester AC/DC/IR/SCAN Keywords: Dielectric tests, insulation resistance
Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal
Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
ELECTRICAL SAFETY RISK ASSESSMENT
ELECTRICAL SAFETY RISK ASSESSMENT The intent of this procedure is to perform a risk assessment, which includes a review of the electrical hazards, the associated foreseeable tasks, and the protective measures
IEC 61439-1 & 2 standard. The reference for safe and reliable LV switchboards
IEC 61439-1 & 2 standard The reference for safe and reliable LV switchboards IEC61439-1 & 2 The power of a standard adapted to your needs IEC standards are today legal or market references. The new IEC
Regulation IO-6.0: Electrical Safety Regulations
Regulation IO-6.0: Electrical Safety Regulations 6.1 Workmanship & Material 6.2 Electrical Conductors 6.3 Overcurrent Protective Devices 6.4 Precautions against Earth Leakage and Earthfault Currents 6.5
Residual Current Circuit Breaker
Introduction Residual Current Circuit Breaker / ELCB The Fault current overloads and short circuits can be detected by circuit breakers like MCB s MCCB s & HRC Fuses etc. But, Circuit breakers don t detect
USER S MANUAL. MaxPower 400-600 UPS. Uninterruptible Power System 28-2MAXPO0018
USER S MANUAL MaxPower 400-600 UPS Uninterruptible Power System 28-2MAXPO0018 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models MaxPower 400 and
Dielectric Withstand Testing in a Production Environment
Dielectric Withstand Testing in a Production Environment Performing a routine product safety test should not in itself represent a shock hazard to the operator who is conducting the test, yet anytime you
MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003
MiCAFIL 1 RIP Technology Z. Zic 09/2003 )XQFWLRQRI+LJK9ROWDJH%XVKLQJ Uncontrolled (natural) electrical field Capacity-controlled electrical field %XVKLQJV0DLQ,QVXODWLRQ6\VWHPV 7\SH 0DLQ,QVXODWLRQ +RXVLQJFRYHU
RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug. 2011. RIGOL Technologies, Inc.
Quick Guide DS1000CA Series Oscilloscope Aug. 2011 Technologies, Inc. Guaranty and Declaration Copyright 2011 Technologies, Inc. All Rights Reserved. Trademark Information is a registered trademark of
UT202A Operating Manual. Contents
Title Contents Page Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Functional Buttons and auto power off Display Symbols