1 Command Control Interface User and Reference Guide Hitachi Virtual Storage Platform G1000 Hitachi Unified Storage VM Hitachi Virtual Storage Platform Hitachi Universal Storage Platform V/VM FASTFIND LINKS Contents Product Version Getting Help MK-90RD

2 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or stored in a database or retrieval system for any purpose without the express written permission of Hitachi, Ltd. Hitachi, Ltd., reserves the right to make changes to this document at any time without notice and assumes no responsibility for its use. This document contains the most current information available at the time of publication. When new or revised information becomes available, this entire document will be updated and distributed to all registered users. Some of the features described in this document might not be currently available. Refer to the most recent product announcement for information about feature and product availability, or contact Hitachi Data Systems Corporation at Notice: Hitachi, Ltd., products and services can be ordered only under the terms and conditions of the applicable Hitachi Data Systems Corporation agreements. The use of Hitachi, Ltd., products is governed by the terms of your agreements with Hitachi Data Systems Corporation. Notice on Export Controls. The technical data and technology inherent in this Document may be subject to U.S. export control laws, including the U.S. Export Administration Act and its associated regulations, and may be subject to export or import regulations in other countries. Reader agrees to comply strictly with all such regulations and acknowledges that Reader has the responsibility to obtain licenses to export, re-export, or import the Document and any Compliant Products. Hitachi is a registered trademark of Hitachi, Ltd., in the United States and other countries. Hitachi Data Systems is a registered trademark and service mark of Hitachi, Ltd., in the United States and other countries. Archivas, Essential NAS Platform, HiCommand, Hi-Track, ShadowImage, Tagmaserve, Tagmasoft, Tagmasolve, Tagmastore, TrueCopy, Universal Star Network, and Universal Storage Platform are registered trademarks of Hitachi Data Systems Corporation. AIX, AS/400, DB2, Domino, DS6000, DS8000, Enterprise Storage Server, ESCON, FICON, FlashCopy, IBM, Lotus, MVS, OS/390, RS/6000, S/390, System z9, System z10, Tivoli, VM/ESA, z/os, z9, z10, zseries, z/ VM, and z/vse are registered trademarks or trademarks of International Business Machines Corporation. All other trademarks, service marks, and company names in this document or website are properties of their respective owners. Microsoft product screen shots are reprinted with permission from Microsoft Corporation. ii

3 Contents Preface xi Intended audience xii Product version xii Document revision level xii Changes in this revision xiii Referenced documents xiii Document conventions xv Convention for storage capacity values xvi Accessing product documentation xvi Getting help xvi Comments xvii 1 Overview About Command Control Interface CCI functions CCI functions matrix Provisioning function Asynchronous command processing Command execution modes Precheck function Command execution by the out-of-band method User authentication LDEV nickname function LDEV grouping function Resource group function Resource locking function CCI functions available on all RAID storage systems In-system replication Remote replication Data protection iii

4 2 CCI software environment Overview of the CCI software environment CCI components on the RAID storage system Command device Command device guarding Alternate command device function Define the remote command device CCI and the SCSI command interface Command competition Command flow Issuing commands for LDEVs within a LUSE device CCI instance components on the host server HORCM operational environment CCI instance configurations Host machines that can be paired Configuration definition file Overview Configuration definition file settings Configuration definition for cascading volume pairs Configuration file and mirror descriptors Cascading connection and configuration files ShadowImage Cascading connections for TrueCopy and ShadowImage CCI software files CCI files supplied with the software CCI files for UNIX-based systems CCI files for Windows-based systems CCI files for OpenVMS-based systems CCI log and trace files CCI log files CCI trace files CCI trace control command Command logging for audit Logging other than raidcom command Logging raidcom command User-created files User environment variable CCI functions Command execution using in-band and out-of-band methods Connecting to CCI server already connected by In-Band method using Out-of-Band method User authentication Command operation authority and user authentication Controlling User Role Controlling user resources iv

5 Commands executed depending on operation authorities Relation between resource groups and command operations Resource lock function Command execution modes Overview Context check How to check Details of check contents Configuration check Resource location and parameter MP blade location and parameter LDEV grouping function Overview Device group definition methods Read operations and command device settings Define device group Device group creation LDEV addition to device group LDEV deletion from device group Device group deletion Copy group function Copy group creation LDEV addition to a copy group LDEV deletion from copy group Copy group deletion Pair operation by specifying a copy group Pair operations with mainframe volumes Using "dummy" LUs for mainframe LDEVs Pair status and access permission for mainframe LDEVs Operational differences for multiplatform volumes Operational differences for replication commands Global virtualization function (VSP G1000 only) System configuration example with the global virtualization function Using CCI in a system configuration with the global virtualization function Specifying a virtual storage machine by HORCM_VCMD Configuration definition file settings when specifying a virtual storage machine by HORCM_VCMD Example of the configuration definition files when specifying a virtual storage machine by HORCM_VCMD Specifying a virtual storage machine by command options Configuration definition file settings when specifying a virtual storage machine by command options Example of the configuration definition files when specifying a virtual storage machine by command options Commands to the virtual storage machine Operation target when you specify the virtual storage machine by the raidcom command v

6 4 Starting up CCI Starting up on UNIX systems Starting up on Windows systems Starting up on OpenVMS systems Starting CCI as a service (Windows systems) Provisioning operations with CCI About provisioning operations Overview of the configuration setting command Synchronous command processing Asynchronous command processing Asynchronous commands Help on configuration setting commands LDEV nickname function Available provisioning operations Available provisioning operation (specifying device group) Summary Operation method Common operations when executing provisioning operations Resource group operations Creating resource groups Deleting resource groups Allocating resources that are allocated to resource groups to other resource groups Execution example Internal volume operations Creating internal volumes (open-systems) Creating internal volumes (Mainframe volume) Script examples Script examples Virtual volume (Dynamic Provisioning) operations Creating virtual volumes (Dynamic Provisioning) Script examples Virtual volume (Dynamic Provisioning for Mainframe) operations Creating virtual volumes (Dynamic Provisioning for Mainframe) Script examples Virtual volume (Dynamic Tiering) operations Operational flow Creating virtual volumes (Dynamic Tiering) Script examples External volume operations Creating external volumes Script Examples Virtual Partition Manager operations Performing Virtual Partition Manager operations vi

7 Displaying CLPR information Migrating parity groups in a CLPR Displaying parity group information Moving parity groups Checking result of CLPR transfer Server Priority Manager operations State transitions of Server Priority Manager Controlling server performance Checking WWN of host bus adapters Setting the priority on host bus adapter Checking the status of the prioritized WWN and the non-prioritized WWN settings Setting SPM name for host bus adapter Grouping multiple host bus adapters into one group Checking the traffic of the prioritized WWN and the non-prioritized WWN Stopping performance control of server by using SPM function Caution about exclusive access control with Storage Navigator Deleting WWN from the SPM targets with SPM name or SPM group name Resource group function and restrictions when running Server Priority Manager Virtual storage machine operations (VSP G1000 only) Creating host groups in a virtual storage machine Adding LDEVs to a virtual storage machine Removing the virtual storage machine Data replication operations with CCI About data replication operations Features of paired volumes Using CCI with ShadowImage and TrueCopy Using CCI with Thin Image Using CCI with global-active device ShadowImage operations ShadowImage duplicated mirroring ShadowImage cascading pairs Restrictions for ShadowImage cascading volumes Restriction for TrueCopy/ShadowImage cascading volumes TrueCopy operations TrueCopy takeover commands Takeover-switch function Swap-takeover function SVOL-takeover function PVOL-takeover function TrueCopy remote commands TrueCopy local commands TrueCopy, ShadowImage, and Universal Replicator operations vii

8 TrueCopy/ShadowImage volumes TrueCopy/ShadowImage/Universal Replicator pair status TrueCopy Async, TrueCopy, and Universal Replicator volumes Sidefile cache for TrueCopy Async TrueCopy Async transition states and sidefile control TrueCopy Async/Universal Replicator error state TrueCopy/TrueCopy Async and Universal Replicator fence level settings Setting the fence level Copy-on-Write Snapshot operations Copy-on-Write Snapshot volumes Creating a Copy-on-Write Snapshot pair Copy-on-Write Snapshot pair status Pair status relationship to Copy-on-Write Snapshot commands Controlling Volume Migration Specifications for Volume Migration Commands to control Volume Migration Relations between "cc" command issues and status Restrictions for Volume Migration Universal Replicator MxN configuration and control Overview Policy horcm.conf Command specifications pairdisplay command pairsplit command Notice on system operation Configuration examples Remote volume discovery Discovering a remote volume Data protection operations with CCI Data protection operations Data Retention Utility Restrictions on Data Retention Utility volumes Database Validator Restrictions on Database Validator Protection parameters and operations Data Protection facility Data Protection Facility specifications Examples for configuration and protected volumes Operation authority with CMD security enabled Target commands for protection permission command New options for security raidscan -find inst raidscan -find verify [MU#] viii

9 raidscan -f[d] pairdisplay -f[d] Permitting protected volumes With a $HORCMPERM file Without a $HORCMPERM file: Commands to run on different operating systems Environment variables $HORCMPROMOD $HORCMPERM Determining the protection mode command device Examples of using CCI commands Group version control for mixed storage system configurations LDM volume discovery and flushing for Windows Volume discovery function Mountvol attached to Windows 2012/2008/2003/2000 systems System buffer flushing function Special facilities for Windows systems Signature changing facility for Windows systems GPT disk for Windows Directory mount facility for Windows systems Host group control Specifying a host group Commands and options including a host group Using CCI SLPR security Specifying the SLPR Protection Facility SLPR configuration examples Troubleshooting General troubleshooting Operational notes and restrictions for CCI operations Error messages and error codes System log messages Command error messages Generic error codes (horctakeover and pair commands) Generic error codes (raidscan, raidqry, raidar, horcctl) Specific error codes SSB codes SSB codes returned by the replication commands SSB codes returned by the configuration setting command (raidcom) Calling the HDS Support Center Index ix

10 x

11 Preface This document describes and provides instructions for using the Command Control Interface software to configure and perform operations on the Hitachi RAID storage systems. Please read this document carefully to understand how to use this product, and maintain a copy for reference purposes. Intended audience Product version Release notes Document revision level Changes in this revision Referenced documents Document conventions Convention for storage capacity values Accessing product documentation Getting help Comments Preface xi

12 Intended audience Product version Release notes This document is intended for system administrators, Hitachi Data Systems representatives, and authorized service providers who are involved in installing, configuring, and operating the Hitachi storage system. Readers of this document should be familiar with the following: Data processing and understands RAID storage systems and their basic functions. The Hitachi RAID storage system and the manual for the storage system (for example, Hitachi Virtual Storage Platform G1000 Product Overview, Hitachi Virtual Storage Platform User and Reference Guide). The management software for the storage system (for example, Hitachi Command Suite, Hitachi Device Manager - Storage Navigator, Storage Navigator) and the applicable user manuals (for example, Hitachi Command Suite User Guide, Hitachi Virtual Storage Platform G1000 Mainframe System Administrator Guide, Hitachi Storage Navigator User Guide for VSP, HUS VM, USP V/VM. This document revision applies to CCI version /01 or later. The Release Notes provide information about the microcode (DKCMAIN and SVP), including new features and functions and changes. The Release Notes are available on the Hitachi Data Systems Portal: Document revision level Revision Date Description MK-90RD October 2010 Initial release MK-90RD December 2010 Supersedes and replaces MK-90RD MK-90RD January 2011 Supersedes and replaces MK-90RD MK-90RD April 2011 Supersedes and replaces MK-90RD MK-90RD August 2011 Supersedes and replaces MK-90RD MK-90RD November 2011 Supersedes and replaces MK-90RD MK-90RD March 2012 Supersedes and replaces MK-90RD MK-90RD June 2012 Supersedes and replaces MK-90RD MK-90RD September 2012 Supersedes and replaces MK-90RD MK-90RD November 2012 Supersedes and replaces MK-90RD MK-90RD December 2012 Supersedes and replaces MK-90RD MK-90RD January 2013 Supersedes and replaces MK-90RD MK-90RD February 2013 Supersedes and replaces MK-90RD MK-90RD March 2013 Supersedes and replaces MK-90RD xii Preface

13 Revision Date Description MK-90RD July 2013 Supersedes and replaces MK-90RD MK-90RD October 2013 Supersedes and replaces MK-90RD MK-90RD December 2013 Supersedes and replaces MK-90RD MK-90RD April 2014 Supersedes and replaces MK-90RD MK-90RD August 2014 Supersedes and replaces MK-90RD Changes in this revision Added support for global-active device operations (Remote replication on page 1-8, Using CCI with global-active device on page 6-5). Added a note about slow command response during out-of-band operations (Command execution using in-band and out-of-band methods on page 3-2). Added information about \HORCM\Tool\TRCLOG.bat and \HORCM\etc\rmsra.exe (CCI files for Windows-based systems on page 2-33). Updated the command to run on HP-UX when no $HORCMPERM file exists (Table 7-3 Without a $HORCMPERM file: Commands to run on different operating systems on page 7-13). Updated the tables of CCI error messages (Error messages and error codes on page 9-6). Referenced documents Hitachi Command Control Interface documents: Command Control Interface Installation and Configuration Guide, MK- 90RD7008 Command Control Interface User and Reference Guide, MK-90RD7010 Hitachi Virtual Storage Platform G1000 documents: Hitachi Virtual Storage Platform G1000 Product Overview, MK- 92RD8051 Hitachi Command Suite User Guide, MK-90HC172 Hitachi Command Suite Messages, MK-90HC178 Hitachi Virtual Storage Platform G1000 Mainframe System Administrator Guide, MK-92RD8016 Hitachi Thin Image User Guide, MK-92RD8011 Hitachi Virtual Storage Platform G1000 Provisioning Guide for Open Systems, MK-92RD8014 Hitachi TrueCopy User Guide, MK-92RD8019 Hitachi ShadowImage User Guide, MK-92RD8021 Hitachi Universal Replicator User Guide, MK-92RD8023 Hitachi Universal Volume Manager User Guide, MK-92RD8024 Preface xiii

14 Global-Active Device User Guide, MK-92RD8072 Hitachi Unified Storage VM documents: Hitachi Unified Storage VM Block Module Provisioning Guide, MK- 92HM7012 Hitachi ShadowImage User Guide, MK-92HM7013 Hitachi Storage Navigator User Guide, MK-92HM7016 Hitachi Storage Navigator Messages, MK-92HM7017 Hitachi TrueCopy User Guide, MK-92HM7018 Hitachi Universal Replicator User Guide, MK-92HM7019 Hitachi Universal Volume Manager User Guide, MK-92HM7020 Hitachi Virtual Storage Platform documents: Hitachi Copy-on-Write Snapshot User Guide, MK-90RD7013 Provisioning Guide for Mainframe Systems, MK-90RD7021 Provisioning Guide for Open Systems, MK-90RD7022 Hitachi ShadowImage for Mainframe User Guide, MK-90RD7023 Hitachi ShadowImage User Guide, MK-90RD7024 Hitachi Storage Navigator User Guide, MK-90RD7027 Hitachi Storage Navigator Messages, MK-90RD7028 Hitachi TrueCopy User Guide, MK-90RD7029 Hitachi TrueCopy for Mainframe User Guide, MK-90RD7030 Hitachi Universal Replicator for Mainframe User Guide, MK-90RD7031 Hitachi Universal Replicator User Guide, MK-90RD7032 Hitachi Universal Volume Manager User Guide, MK-90RD7033 Hitachi Thin Image User Guide, MK-90RD7179 Hitachi Universal Storage Platform V/VM documents: Hitachi Copy-on-Write Snapshot User Guide, MK-96RD607 LUN Manager User s Guide, MK-96RD615 Hitachi ShadowImage for IBM z/os User Guide, MK-96RD619 Hitachi ShadowImage User Guide, MK-96RD618 Hitachi Storage Navigator User Guide, MK-96RD621 Hitachi Storage Navigator Messages, MK-96RD613 Hitachi TrueCopy User Guide, MK-96RD622 Hitachi TrueCopy for IBM z/os User s Guide, MK-96RD623 Hitachi Universal Replicator for IBM z/os User s Guide, MK-96RD625 Hitachi Universal Replicator User Guide, MK-96RD624 Hitachi Universal Volume Manager User Guide, MK-96RD626 xiv Preface

15 Document conventions This document uses the following terminology conventions: Convention Hitachi RAID storage system Hitachi enterprise storage system Description Refers to all supported models, unless otherwise noted. The Hitachi RAID storage systems include the following models: Hitachi Virtual Storage Platform G1000 Hitachi Unified Storage VM Hitachi Virtual Storage Platform Hitachi Universal Storage Platform V/VM Hitachi TagmaStore Universal Storage Platform Hitachi TagmaStore Network Storage Controller Refers to the Hitachi RAID storage systems except for the Hitachi Unified Storage VM. This document uses the following typographic conventions: Convention Description Regular text bold Italic Screen text In text: keyboard key, parameter name, property name, hardware label, hardware button, hardware switch In a procedure: user interface item Variable, emphasis, reference to document title, called-out term Command name and option, drive name, file name, folder name, directory name, code, file content, system and application output, user input < > (angle brackets) Variable (used when italic is not enough to identify variable) [ ] (square brackets) Optional value { } (braces) Required or expected value (vertical bar) Choice between two or more options or arguments This document uses the following icons to draw attention to information: Icon Meaning Description Tip Provides helpful information, guidelines, or suggestions for performing tasks more effectively. Note Provides information that is essential to the completion of a task. Caution WARNING Warns that failure to take or avoid a specified action can result in adverse conditions or consequences (for example, loss of access to data). Warns that failure to take or avoid a specified action can result in severe conditions or consequences (for example, loss of data). Preface xv

16 Convention for storage capacity values Physical storage capacity values (for example, disk drive capacity) are calculated based on the following values: Physical capacity unit Value 1 KB 1,000 bytes 1 MB 1,000 KB or 1,000 2 bytes 1 GB 1,000 MB or 1,000 3 bytes 1 TB 1,000 GB or 1,000 4 bytes 1 PB 1,000 TB or 1,000 5 bytes 1 EB 1,000 PB or 1,000 6 bytes Logical storage capacity values (for example, logical device capacity) are calculated based on the following values: Logical capacity unit Value Accessing product documentation Getting help 1 KB 1,024 bytes 1 MB 1,024 KB or 1,024 2 bytes 1 GB 1,024 MB or 1,024 3 bytes 1 TB 1,024 GB or 1,024 4 bytes 1 PB 1,024 TB or 1,024 5 bytes 1 EB 1,024 PB or 1,024 6 bytes 1 block 512 bytes 1 cylinder (cyl) Open-systems: OPEN-V: 960 KB Other than OPEN-V: 720 KB Mainframe: 870 KB The user documentation for CCI and the Hitachi storage systems is available on the Hitachi Data Systems Portal: Check this site for the most current documentation, including important updates that may have been made after the release of the product. The Hitachi Data Systems customer support staff is available 24 hours a day, seven days a week. If you need technical support, log on to the Hitachi Data Systems Portal for contact information: xvi Preface

17 Comments Please send us your comments on this document: Include the document title and number, including the revision level (for example, -07), and refer to specific sections and paragraphs whenever possible. All comments become the property of Hitachi Data Systems Corporation. Thank you! Preface xvii

18 xviii Preface

19 1 Overview This chapter provides an overview of the Command Control Interface software and CCI operations on the Hitachi RAID storage systems. About Command Control Interface CCI functions CCI functions available on all RAID storage systems Overview 1 1

20 About Command Control Interface CCI functions The Command Control Interface software enables you to perform storage system configuration and data management operations by issuing commands to the Hitachi RAID storage systems: Hitachi Virtual Storage Platform G1000 (VSP G1000) Hitachi Unified Storage VM (HUS VM) Hitachi Virtual Storage Platform (VSP) Hitachi Universal Storage Platform V/VM (USP V/VM) Hitachi TagmaStore Universal Storage Platform (TagmaStore USP) Hitachi TagmaStore Network Storage Controller (TagmaStore NSC) CCI continues to provide the proven functionality that has been available for the USP V/VM and previous storage system models, including in-system replication, remote replication, and data protection operations. In addition, CCI for VSP and later now provides command-line access to the same provisioning and storage management operations that are available in the Hitachi Storage Navigator graphical user interface. CCI commands can be used interactively or in scripts to automate and standardize storage administration functions, thereby simplifying the job of the storage administrator and reducing administration costs. Caution: Some storage systems may reject commands from CCI. If a CCI command is rejected, verify the software licenses for the storage system (for example, TrueCopy) and the status of the software product and storage system. CCI functions matrix The following table lists and describes CCI functions available on each storage system. Table 1-1 Available CCI functions on each storage system Storage system Function TagmaStore USP/NSC USP V/VM VSP HUS VM VSP G1000 Local copy (open) Yes Yes Yes Yes Yes Local copy (mainframe) No No Yes* No Yes Remote copy (open) Yes Yes Yes Yes Yes Remote copy No No Yes* No Yes (mainframe) Data protection Yes Yes Yes Yes Yes VSS configuration Yes Yes Yes Yes Yes SRM SRA Yes Yes Yes Yes Yes 1 2 Overview

21 Storage system Function TagmaStore USP/NSC USP V/VM VSP HUS VM VSP G1000 Provisioning (raidcom) No No Yes Yes Yes Out-of-band method No No Yes Yes Yes User authentication No No Yes Yes Yes LDEV nickname No No Yes Yes Yes LDEV group No No Yes Yes Yes Resource group No No Yes Yes Yes Resource lock No No Yes Yes Yes *If DKCMAIN Microcode version of the VSP storage system is x-xx/xx or later, the operation of TrueCopy for Mainframe, Universal Replicator for Mainframe, and ShadowImage for Mainframe can be performed from Command Control Interface. Provisioning function By executing a configuration setting command (raidcom command) from CCI, the provisioning function such as setting commands or creating LDEVs can be done. For the information about the configuration setting command (raidcom command), see Overview of the configuration setting command on page 5-2. Asynchronous command processing Within the configuration setting commands (raidcom commands), using asynchronous commands is a method of command processing applied to a command that takes much time in processing on the storage system. Once this processing method of command is issued, an additional command can be executed without having to wait for the command completion that executed just before. It is also possible to monitor the completion status by using a status reference command. Overview 1 3

22 Command execution modes Precheck function CCI provides two command execution modes: transaction mode that executes by specifying a script file with -zt option, and line-by-line mode that executes a command row-by-row for the configuration setting commands (raidcom commands). The transaction mode can execute the following checking. Context check: This check is executed when a script file is specified by -zt option. It checks the context of preceding commands and determines whether a subsequent command can be executed. Specifying example: > raidcom -zt <script_file> Configuration check: This check verifies that the actual storage system confirmation is valid (implemented) for the resources specified in the commands (LDEVs, ports, pools, etc.). Syntax example: > raidcom get ldev -ldev_id -cnt store<work_file> > raidcom -zt <script_file> -load<work_file> CCI provides a precheck function that checks a configuration command before executing the command for the configuration setting commands (raidcom commands): In previous versions of CCI, an error was returned when the syntax of a command to be executed was not correct. Now the precheck function checks the command syntax before the command is issued. To use this function, specify either the -checkmode precheck option or the -zt option. The following table shows the checking function combinations between the precheck function and the transaction mode. Table 1-2 Summary of the checking functions Command syntax Syntax check Context check Config check Execution raidcom <command> Executed Not executed raidcom <command> -checkmode precheck Executed Not executed Not executed Not executed raidcom -zt <script file> Executed Executed Not executed raidcom get ldev -ldev_id -cnt store<work_file> raidcom -zt <script_file> -load <work_file> Executed Not executed Executed Executed Executed Executed Executed raidcom -zt <script file> -checkmode precheck Executed Executed Not executed Not executed 1 4 Overview

23 Command syntax Syntax check Context check Config check Execution raidcom get ldev -ldev_id -cnt store<work_file> raidcom -zt <script_file> -load <work_file> -checkmode precheck Executed Executed Executed Not executed Command execution by the out-of-band method In the CCI before supporting Hitachi Virtual Storage Platform, a command can be executed only from the host connected by the fibre channel directly. This is known as in-band operations. In the CCI supporting Hitachi Virtual Storage Platform, a command can be executed from any client PC connected to the storage system via LAN, not just from connected hosts. This is known as out-of-band operations. For in-band CCI operations, the command device is used, which is a user-selected and dedicated logical volume on the storage system that functions as the interface to the storage system on the UNIX/PC host. The command device accepts read and write commands that are executed by the storage system. For out-of-band CCI operations, a virtual command device is used. The virtual command device is defined in the configuration definition file by an IP address on the SVP. CCI commands are issued from the client or the host server and transferred via LAN to the virtual command device, and the requested operations are then performed by the storage system. The following figure illustrates in-band and out-of-band CCI operations. Overview 1 5

24 Figure 1-1 Overview of out-of-band and in-band operations The following table provides a comparison of in-band and out-of-band operations. Table 1-3 Comparison of in-band and out-of-band operations Route Command Specification In-band (issued from the host as if it were a command for the command device) Out-of-band (communicating directly with the SVP) Replication Provisioning Replication Provisioning The required or not required of user authentication is changed by the setting of user authentication. User authentication is required. User authentication is required. User authentication is required. 1 6 Overview

25 User authentication To enable user authentication, it is required to enable the user authentication mode for the command device of CCI. A virtual command device always enables the user authentication mode. If the authentication is disabled, provisioning commands and out-of-band commands cannot be executed. The user information to be used (user ID and password) are the same as those used for Storage Navigator and the SVP. LDEV nickname function A unique nickname with up to 32 characters can be given to an LDEV. LDEV grouping function In CCI before supporting Hitachi Virtual Storage Platform, it was required to define a copy group for the configuration definition file on each host. When changing copy group information, editing of the configuration definition file was required on each host. In CCI supporting VSP, the group information that is registered into the storage system can be used as it is. The LDEV grouping function for VSP can minimize the description of the configuration definition file of CCI on each host. When the copy group information changes, you need to update only one configuration file, saving time and eliminating the chance for error due to mismatching edits. This new functionality is implemented using device names, device groups, and copy groups: Device name: A name that can be given in one LDEV per the device group. Each name is associated with a device group in which the LDEV belongs to. An LDEV nickname can be given to the LDEV as a unique name for the LDEV that is not related with device group. Only one LDEV nickname can be given for each LDEV. Device group: A group of one or more LDEVs. One LDEV can belong to multiple device groups. A device group can belong to only one copy group. If you want to construct a mirror or cascade, you need to define a different device group and a device name in each copy group. Copy group: A group that is defined by specifying two device groups: one device group at the primary side and one device group at the secondary side. Overview 1 7

26 Resource group function Using Resource Group function, the storage administrator for each resource group can access only the resources in the resource group. The storage administrator cannot access resources in other resource groups. This prevents the risk of destroying the data by another storage administrator in the other resource groups or of leaking out the data. Resource locking function The resource locking function prevents conflict among multiple users: User scripts cannot be guaranteed to work correctly when there are multiple users (Storage Navigator and SVP). You can use the lock command while the script is running to ensure completion.to use the lock command, user authentication is required. CCI functions available on all RAID storage systems CCI provides the following functionality on all Hitachi Data Systems RAID storage systems. In-system replication Remote replication Data protection In-system replication Remote replication CCI provides command-line control for in-system (local) replication operations, including ShadowImage, Thin Image, and Copy-on-Write Snapshot. CCI displays local replication information and allows you to perform operations by issuing commands or by executing script files. CCI provides command-line control for remote replication operations, including TrueCopy, Universal Replicator, and global-active device. CCI displays remote replication information and allows you to perform operations by issuing commands or by executing script files. For remote copy operations, CCI interfaces with the system software and high-availability (HA) software on the host as well as the software on the RAID storage system. CCI provides failover operation commands that support mutual hot standby in conjunction with industry-standard failover products (for example, MC/ServiceGuard, HACMP, FirstWatch ). CCI also supports a scripting function for defining multiple operations in a script (or text) file. Using CCI scripting, you can set up and execute a large number of commands in a short period of time while integrating host-based highavailability control over copy operations. 1 8 Overview

27 Data protection CCI supports data protection operations, including Hitachi Database Validator and Hitachi Data Retention Utility. Database Validator. The CCI software provides commands to set and verify parameters for volume-level validation checking of Oracle database operations. Once validation checking is enabled, all write operations to the specified volumes must have valid Oracle checksums. CCI reports a validation check error to the syslog file each time an error is detected. Database Validator requires the operation of CCI software product but cannot be controlled via the Storage Navigator software. Data Retention Utility. The CCI software enables you to set and verify the parameters for guarding at the volume level. Once guarding is enabled, the RAID storage system conceals the target volumes from SCSI commands such as SCSI Inquiry and SCSI Read Capacity, prevents reading and writing to the volume, and protects the volume from being used as a copy volume (the TrueCopy, Universal Replicator or ShadowImage paircreate operation fails). Overview 1 9

28 1 10 Overview

29 2 CCI software environment This chapter describes the CCI software environment. Overview of the CCI software environment CCI components on the RAID storage system CCI instance components on the host server CCI software files CCI log and trace files User-created files User environment variable CCI software environment 2 1

30 Overview of the CCI software environment The CCI software environment includes components on the Hitachi RAID storage systems and the CCI software on the host servers and/or on the Storage Navigator computer. The CCI components on the storage systems include the user data volumes and CCI command devices. Each CCI instance on a host server includes: CCI application files, referred to as HORC Manager (HORCM): Log and trace files A command server Error monitoring and event reporting files A configuration management feature Configuration definition file (user-defined) User execution environments for the HDS features, including the commands, a command log, and a monitoring function. The CCI commands also have interface considerations (see CCI and the SCSI command interface on page 2-6). CCI components on the RAID storage system Command device CCI commands are issued by the CCI software to the RAID storage system command device. The command device is a user-selected, dedicated logical volume on the storage system that functions as the interface to the CCI software on the host. The command device is dedicated to CCI communications and cannot be used by any other applications. The command device accepts CCI read and write commands that are issued by the storage system. The command device also returns read requests to the host. The volume designated as the command device is used only by the storage system and is blocked from the user. The command device uses 16 MB, and the remaining volume space is reserved for CCI and its utilities. The command device can be any OPEN-x device (for example, OPEN-V) that is accessible to the host. A LUN Expansion volume cannot be used as a command device. A Virtual LVI/Virtual LUN volume as small as 36 MB (for example, OPEN-3-CVS) can be used as a command device. WARNING: Make sure the volume to be selected as the command device does not contain any user data. The command device will be inaccessible to the host. The CCI software on the host issues read and write commands to the command device. When CCI receives an error notification in reply to a read or write request to the RAID storage system, the CCI software switches to an alternate command device, if one is defined. If a command device is blocked (for example, for online maintenance), you can switch to an alternate command device manually. If no alternate command device is defined or available, all TrueCopy and ShadowImage commands terminate abnormally, and the host will not be able to issue commands to the storage 2 2 CCI software environment

31 system. Therefore, one or more alternate command devices (see Alternate command device function on page 2-5) must be set to avoid data loss and storage system downtime. Each command device must be set using the LUN Manager software on Storage Navigator. In addition, for using a Provisioning command, user authentication is required. Set the security attribute of the command device with user authentication. For information and instructions on setting a command device, see the Provisioning Guide for the storage system. Each command device must also be defined in the HORCM_CMD section of the configuration file for the CCI instance on the attached host. If an alternate command device is not defined in the configuration file, the CCI software may not be able to use the device. The CCI Data Protection Facility uses an enhanced command device that has an attribute to indicate protection ON or OFF. Note: For Solaris operations, the command device must be labeled. To enable dual path of the command device, make sure to include all paths to the command device on a single line in the HORCM_CMD section of the configuration file. The following shows an example with two controller paths to the command device. Putting the path information on separate lines may cause parsing issues, and failover may not occur unless the HORCM startup script is restarted. HORCM_CMD #dev_name dev_name dev_name /dev/rdsk/c1t66d36s2 / dev/rdsk/c2t66d36s2 Command device guarding In the customer environment, a command device may be attacked by the maintenance program of the Solaris Server, after that usable instance will be exhausted, and CCI instance would not start up on all servers (except attacked server). This may happen due to incorrect operation of the maintenance personnel for the UNIX Server. In this case, the command device should be protected against operator error, as long as it can be seen as the device file from the maintenance personnel. Thus, the RAID microcode (for the command device) and CCI support this protection in order to guard from similar access. Guarding method Currently, assignment of the instance via the command device is ONE phase. Therefore, if the command device reads a special allocation area of the instance through the maintenance tool and so on, then it causes a fault of full space of the instance, because the command device interprets as assignment of the instance from CCI. CCI software environment 2 3

32 CCI has TWO phases that it reads to acquire usable LBA, and writes with the acquired LBA in attaching sequence to the command device, so the command device can confirm whether it was required as the assignment for CCI or not, by detecting and adding two status bits to the instance assignment table. Figure 2-1 Current assignment sequence Figure 2-2 Improved assignment sequence The command device performs the assignment of an instance through TWO phases that have "temporary allocation (1 0)" and "actual allocation (1 1)" to the instance assignment table. If the command device is attacked, the instance assignment table is filled with "temporary allocation (1 0)" status. After that, the command device will detect a fault of full space as the instance assignment, clear up all "temporary allocation (1 0)", and then reassign the required instance automatically. This does not require a service representative to switch the command device "OFF/ON" to clear up the instance table. Verifying the CCI instance number CCI provides a way to verify the number of "temporary allocations (1 0)" and "actual allocations (1 1)" on the instance table so that you can confirm validity of the CCI instance number in use. The horcctl -DI command shows the number of CCI instances since HORCM was started as follows. Example without command device security: 2 4 CCI software environment

33 # horcctl -DI Current control device = /dev/rdsk/c0t0d0 AI = 14 TI = 0 CI = 1 Example with command device security: # horcctl -DI Current control device = /dev/rdsk/c0t0d0* AI = 14 TI = 0 CI = 1 AI : NUM of actual instances in use TI : NUM of temporary instances in RAID CI : NUM of instances using current (own) instance Alternate command device function The CCI software issues commands to the command device via the UNIX/ PC raw I/O interface. If the command device fails in any way, all CCI commands are terminated abnormally, and you cannot use any commands. Because the use of alternate I/O path is platform dependent, restrictions are placed upon it. For example, on HP-UX systems, only devices subject to the LVM can use the alternate path PV-LINK. To avoid command device failure, CCI supports an alternate command device function. Definition of alternate command devices. To use an alternate command device, you must define two or more command devices for the HORCM_CMD item in the configuration definition file. When two or more devices are defined, they are recognized as alternate command devices. Timing of alternate command devices. When the HORCM receives an error notification in reply from the operating system via the raw I/O interface, the alternate command device is used. It is possible to force a switch to use the alternate the command device by issuing the horcctl -C switch command provided by CCI. Operation of alternating command. If the command device is blocked due to online maintenance, the switch command should be issued in advance. If the switch command is issued again after completion of the online maintenance, the previous command device is activated. Multiple command devices on HORCM startup. If at least one command device is available during one or more command devices described to the configuration definition file, then HORCM can start with a warning message to the startup log by using the available command device. Confirm that all command devices can be changed by using the horcctl -C command option, or HORCM has been started without the warning message to the HORCM startup log. CCI software environment 2 5

34 Define the remote command device The command device of external storage system that is mapped as a command device of the local storage system is called as remote command device. By issuing a command to the remote command device, the operation at the external storage system is realized. The remote command device is defined by the Storage Navigator. For more information, see the Hitachi Universal Volume Manager User Guide. CCI and the SCSI command interface Figure 2-3 Alternate Command Device Function When CCI commands are converted into a special SCSI command format, a SCSI through driver that can send specially formatted SCSI commands to the RAID storage system is needed. As a result, OS support for CCI depends on the OS capabilities. It is necessary to use a read/write command that can easily be issued by many UNIX/PC server platforms. For example, ioctl() can be used for the following platforms: HP-UX, Linux, Solaris, Windows, IRIX64, OpenVMS and zlinux. SCSI command format used. Use a RD/WR command that can be used with special LDEVs, since they should be discriminated from the normal RD/ WR command. Recognition of the control command area (LBA#). The host issues control commands through the raw I/O special file of a special LDEV. Since the specific LU (command device) receiving these commands is viewed as a normal disk by the SCSI interface, the OS can access its local control area. The RAID storage system must distinguish such accesses from the control command accesses. Normally, several megabytes of the OS control area are used starting at the initial LBA#. To avoid using this area, a specific LBA# area is decided and control commands are issued within this area. The command LBA# recognized by the storage system is shown below, provided the maximum OS control area is 16 MB. 2 6 CCI software environment

35 Figure 2-4 Relationship of the special file to the special LDEV Command competition Acceptance of commands. A command is issued in the LBA area of the special LDEV explained above. The RD/WR command meeting this requirement should be received especially as a CCI command. A command is issued in the form of WR or WR-RD. When a command is issued in the form of RD, it is regarded as an inquiry (equivalent to a SCSI inquiry), and a CCI recognition character string is returned. The CCI commands are asynchronous commands issued via the SCSI interface. As a result, if several processes issue these commands to a single LDEV, the storage system cannot take the proper action. To avoid such a problem, two or more write commands should not be issued to a single LDEV. The command initiators should not issue two or more write commands to a single LDEV unless the storage system can receive commands with independent initiator number * LDEV number simultaneously. Figure 2-5 HORCM and command issue process CCI software environment 2 7

36 Command flow This figure shows the flow of read/write command control for a specified LBA#. Figure 2-6 Command flow Issuing commands for LDEVs within a LUSE device A LUSE device is a group of LDEVs regarded as a single logical unit. Because it is necessary to know the configuration of the LDEVs when issuing a command, a new command is used to specify a target LU and acquire LDEV configuration data, as shown in the following figure. Figure 2-7 LUSE Device and Command Issue 2 8 CCI software environment

37 CCI instance components on the host server HORCM operational environment The HORCM operates as a daemon process on the host server and is activated either automatically when the server machine starts up or manually by the startup script. HORCM reads the definitions specified in the configuration file upon startup. The environment variable HORCM_CONF is used to define the location of the configuration file to be referenced. CCI instance configurations Figure 2-8 HORCM operational environment The basic unit of the CCI software structure is the CCI instance. A CCI instance consists of HORC manager (HORCM), CCI commands, the userdefined configuration definition file, and the log function for maintenance. Each instance uses its own configuration definition file to manage volume relationships while maintaining awareness of the other CCI instances. Each CCI instance normally resides on separate servers (one node per instance). If two or more instances are run on a single server (for example, for test operations), it is possible to activate two or more instances using instance numbers. The CCI commands to be used are selected by the environment variable (HORCC_MRCF). The default command execution environment for CCI is TrueCopy. The CCI instance shown in the following figure has a remote execution link and a connection to the RAID storage system. The remote execution link is a network connection to another PC to allow you to execute CCI functions remotely. The connection between the CCI instance and the storage system illustrates the connection between the CCI software on the host and the command device. The command device accepts CCI commands and communicates read and write I/Os between the host and the volumes on CCI software environment 2 9

38 the storage system. The host does not communicate CCI commands directly to the volumes on the storage system -- the CCI commands always go through the command device. Figure 2-9 CCI instance configuration & components The four possible CCI instance configurations are: One host connected to one storage system. Connecting one host to one storage system allows you to maintain multiple copies of your data for testing purposes or as an offline backup. Each CCI instance has its own operation manager, server software, and scripts and commands, and each CCI instance communicates independently with the command device. The RAID storage system contains the command device that communicates with the CCI instances as well as the primary and secondary volumes of both CCI instances CCI software environment

39 One host connected to two storage systems. Connecting the host to two storage systems enables you to migrate data or implement disaster recovery by maintaining duplicate sets of data in two different storage systems. You can implement disaster recovery solutions by placing the storage systems in different geographic areas. Each CCI instance has its own operation manager, server software, and scripts and commands, and each CCI instance communicates independently with the command device. Each RAID storage system has a command device that communicates with each CCI instance independently. Each storage system contains the primary volumes of its connected CCI instance and the secondary volumes of the other CCI instance (located on the same host in this case). Two hosts connected to one storage system. Having two attached hosts to one storage system, one host for the primary volume and the other host for the secondary volume, allows you to maintain and administer the primary volumes while the secondary volumes can be taken offline for testing. The CCI instances of separate hosts are connected via the LAN so that they can maintain awareness of each other. The RAID storage system contains the command device that communicates with both CCI instances (one on each host) and the primary and secondary volumes of both CCI instances Two hosts connected to two storage systems. Two hosts connected to two storage systems also allows the most flexible disaster recovery plan, because both sets of data are administered by different hosts. This guards against storage system failure as well as host failure.the CCI instances of separate hosts are connected via the LAN so that they can maintain awareness of each other. Each RAID storage system has a command device that communicates with each CCI instance independently. Each storage system contains the primary volumes of its connected CCI instance and the secondary volumes of the other CCI instance (located on a different host in this case). Host machines that can be paired When you perform a pair operation, the version of CCI should be the same on the primary and secondary sites. As a particular application uses HORC, users sometimes use a HORC volume as the data backup volume for the server. In this case, CCI requires that the CCI instance correspond to each OS platform that is located on the secondary site for the pair operation of data backup on the primary servers of each OS platform. However, it is possible to prepare only one server at a secondary site by supporting CCI communications among different OSs (including the converter for little-endian vs. big-endian). Figure 2-10 CCI communication among different operating systems on page 2-12 represents CCI's communication among different OSs, and Table 2-1 Supported CCI (HORCM) communication on page 2-12 shows the supported communication (32-bit, 64-bit) among different OSs. Please note the following terms that are used in the example: RM-H: Value of HORCMFCTBL environment variable for an HP-UX CCI instance on Windows CCI software environment 2 11

40 RM-S: Value of HORCMFCTBL environment variable for a Solaris CCI instance on Windows Restriction: CCI's communications among different operating systems is supported on HP-UX, Solaris, AIX, Linux, and Windows (this is not supported on Tru64 UNIX/Digital UNIX). Also, CCI does not require that the HORCMFCTBL environment variable be set except for RM-H and RM-S instances (to ensure that the behavior of the operating system platform is consistent across different operating systems). Figure 2-10 CCI communication among different operating systems Table 2-1 Supported CCI (HORCM) communication HORCM HORCM 32 bit HORCM 64 bit little big little big Configuration definition file Overview 32 bit little AV AV AV - big AV AV AV - 64 bit little AV AV AV - big The CCI configuration definition file is a text file that defines a CCI instance. The connected hosts, volumes and groups known to the CCI instance are defined in the configuration definition file. Physical volumes (special files) used independently by the servers are combined when paired logical volume names and group names are given to them. The configuration definition file describes the correspondence between the physical volumes used by the servers and the paired logical volumes and the names of the 2 12 CCI software environment

41 remote servers connected to the volumes. See the Command Control Interface Installation and Configuration Guide for instructions on creating the CCI configuration definition file. Figure 2-11 Configuration definition of paired volumes on page 2-13 illustrates the configuration definition of paired volumes. Figure 2-11 Configuration definition of paired volumes Configuration file example UNIX-based servers Note that # at the beginning of a line indicates a comment. HORCM_MON #ip_address service poll(10ms) timeout(10ms) HST1 horcm HORCM_CMD #unitid 0... (seq#30014) #dev_name dev_name dev_name /dev/rdsk/c0t0d0 #unitid 1... (seq#30015) #dev_name dev_name dev_name /dev/rdsk/c1t0d0 HORCM_DEV #dev_group dev_name port# TargetID LU# MU# oradb oradb1 CL1-A oradb oradb2 CL1-A CCI software environment 2 13

42 oralog oralog1 CL1-A 5 0 oralog oralog2 CL1-A1 5 0 oralog oralog3 CL1-A1 5 1 oralog oralog4 CL1-A1 5 1 h1 HORCM_INST #dev_group ip_address service oradb HST2 horcm oradb HST3 horcm oralog HST3 horcm Configuration file example Windows servers The following table lists the parameters defined in the configuration file and specifies the default value, type, and limit for each parameter. Table 2-2 Configuration (HORCM_CONF) parameters Parameter Default Type Limit ip_address None Character string 63 characters Service None Character string or numeric 15 characters value poll (10 ms) 1000 Numeric value 1 None timeout (10 ms) 3000 Numeric value 1 None dev_name for HORCM_CMD dev_name for HORCM_DEV None Character string 63 characters Recommended value = 8 char. or fewer None Character string 31 characters 2 14 CCI software environment

43 Parameter Default Type Limit dev_group None Character string 31 characters Recommended value = 8 char. or less port # None Character string 31 characters target ID None Numeric value 1 7 characters LU# None Numeric value 1 7 characters MU# 0 Numeric value 1 7 characters Serial# 2 None Numeric value 12 characters CU:LDEV(LDEV#) None Numeric value 6 characters dev_name for HORCM_CMD None Character string 63 characters Recommended value = 8 char. or less Notes: 1. Use decimal notation for numeric values (not hexadecimal). 2. For VSP G1000, add a 3 at the beginning of the serial number. For example, for serial number 12345, enter Do not edit the configuration definition file while CCI is running. Shut down CCI, edit the configuration file as needed, and then restart CCI. Do not mix pairs created with the "At-Time Split" option (-m grp) and pairs created without this option in the same group defined in the CCI configuration file. If you do, a pairsplit operation might end abnormally, or S-VOLs of the P-VOLs in the same consistency group (CTG) might not be created correctly at the time the pairsplit request is received. Configuration definition file settings (1) HORCM_MON The monitor parameter (HORCM_MON) defines the following values: Ip_address: The IP address of the local host. When HORCM has two or more network addresses on different subnets for communication, this must be set to NONE. Service: Specifies the UDP port name assigned to the HORCM communication path, which is registered in "/etc/services" ("%windir%\system32\drivers\etc\services" in Windows, "SYS$SYSROOT:[ TCPIP$ETC]SERVICES.DAT" in OpenVMS). If a port number is specified instead of a port name, the port number will be used. Poll: The interval for monitoring paired volumes. To reduce the HORCM daemon load, make this interval longer. If set to -1, the paired volumes are not monitored. The value of -1 is specified when two or more CCI instances run on a single machine. Timeout: The time-out period of communication with the remote server. CCI software environment 2 15

44 If HORCM_MON is not specified, then the following are set as defaults. HORCM_MON #ip_address service poll(10ms) timeout(10ms) NONE default_port H Default_port: For none specified HORCM instance: " " For instance HORCM X : " X + 1" (2) HORCM_CMD When using the in-band method, this command parameter (HORCM_CMD) defines the UNIX device path or Windows physical device number and specifies a command device that can access the CCI. In-band method The command device must be mapped to the SCSI/fibre using LUN Manager. You can define more than one command device to provide failover in case the original command device becomes unavailable (see Alternate command device function on page 2-5). The mapped command devices can be identified by the "-CM" of product ID field of the inqraid command. # ls /dev/rdsk/c1t0* /HORCM/usr/bin/inqraid -CLI -sort DEVICE_FILE PORT SERIAL LDEV CTG H/M/12 SSID R:Group PRODUCT_ID c1t0d0s2 CL2-E OPEN-V-CM c1t0d1s2 CL2-E s/s/ss :02-01 OPEN-V -SUN c1t0d2s2 CL2-E s/s/ss :02-01 OPEN-V -SUN The command device of UNIX host (Solaris) is described in the following. /dev/rdsk/c1t1d0s2 The command device of Windows host is described as follows. \\.\PhysicalDrive2 or \\.\CMD After the process of command device mapping, set HORCM_CMD of the configuration definition file as follows. \\.\CMD-<Serial Number>:<Device special file name> <Serial Number>: Sets the serial number. For VSP G1000, add a 3 at the beginning of the serial number. For example, for serial number 12345, enter <Device special file name>: Sets the device special file name of a command device. Example When the serial number and device special file name, /dev/rdsk/*is specified: 2 16 CCI software environment

45 HORCM_CMD #dev_name dev_name dev_name \\.\CMD-64015:/dev/rdsk/* Out-of-band method When executing commands using the out-of-band method, create a virtual command device. To create a virtual command device, specify as the following to HORCM_CMD of the configuration definition file. \\.\IPCMD-<SVP IP address>-<udp communication port number>[- Unit ID] <SVP IP address>: Sets an IP address of SVP. <UDP communication port number>: Sets the UDP communication port number. This value is fixed (31001). [-Unit ID]: Sets the unit ID of the storage system for the multiple units connection configuration. This can be omitted. Example for IPv4: HORCM_CMD#dev_name dev_name \\.\IPCMD Example for IPv6: HORCM_CMD#dev_name dev_name \\.\IPCMD-fe80::209:6bff:febe:3c dev_name dev_name Note: To enable dual path of the command device under Solaris systems, make sure to include all paths to the command device on a single line in the HORCM_CMD section of the config file. Putting the path information on separate lines may cause parsing issues, and failover may not occur unless the HORCM startup script is restarted on the Solaris system. When a server is connected to two or more storage systems, the HORCM identifies each storage system using the unit ID (see Figure 2-12 Configuration and unit IDs for multiple storage systems on page 2-18). The unit ID is assigned sequentially in the order described in this section of the configuration definition file. When the storage system is shared by two or more servers, each server must be able to verify that the unit ID is the same Serial# (Seq#) among servers. This can be verified using the raidqry command. CCI software environment 2 17

46 Figure 2-12 Configuration and unit IDs for multiple storage systems dev_name for Windows In Windows SAN environment, "Volume{guid}" will be changed on every reboot under MSCS/Windows 2003, if Windows finds the same signature on the command device connected with Multi-Path.Therefore, find NEW "Volume{guid}", and change "Volume{guid}" described in the CCI configuration file. Thus, CCI supports the following naming format specifying Serial#/LDEV#/Port# as notation of the command device only for Windows. For VSP G1000, add a 3 at the beginning of the serial number. For example, for serial number 12345, enter \\.\CMD-Ser#-ldev#-Port# HORCM_CMD #dev_name dev_name dev_name \\.\CMD CL1-A To allow more flexibility, CCI allows the following format. For minimum specification Specifies to use any command device for Serial#30095 \\.\CMD If Windows has two different array models that share the same serial number, fully define the serial number, ldev#, port and host group for the CMDDEV. For under Multi Path Driver Specifies to use any port as the command device for Serial#30095, LDEV#250 \\.\CMD For full specification Specifies the command device for Serial#30095, LDEV#250 connected to Port CL1-A, Host group#1 \\.\CMD CL1-A CCI software environment

47 Other example \\.\CMD CL1-A \\.\CMD CL1 dev_name for UNIX In the UNIX SAN environment, a device file name is changed at the failover operation under the UNIX SAN environment, or each reboot process under the Linux when the SAM is reconfigured. CCI user is required to change the HORCM_CMD described in the CCI configuration file by searching new "Device special file". Therefore, CCI supports the following naming format to specify "Serial#/LDEV#/Port#:HINT" as an expression way of command device for UNIX. For VSP G1000, add a 3 at the beginning of the serial number. For example, for serial number 12345, enter \\.\CMD-Ser#-ldev#-Port#:HINT HORCM_CMD #dev_name dev_name dev_name \\.\CMD CL1-A-1:/dev/rdsk/ Once this name is specified, HORCM finds the "\CMD-Serial#-Ldev#-Port#" from the device file specified by the HINT at the time of HORCM startup. HINT must specify to be end with "/" for the directory of the device file name or the directory that includes the pattern of device filename, as shown in the following. Finds CMD, which is specified by /dev/rdsk/:/dev/rdsk/* Finds CMD, which is specified by /dev/rdsk/c10:/dev/rdsk/c10* Finds CMD, which is specified by /dev/rhdisk:/dev/rhdisk* A device file is displayed while HINT is filtered with the following pattern. HP-UX: /dev/rdsk/* or /dev/rdisk/disk* Solaris: /dev/rdsk/*s2, AIX: /dev/rhdisk* Linux: /dev/sd..., zlinux : /dev/sd... Tru64: /dev/rrz*c or /dev/rdisk/dsk*c or /dev/cport/scp* IRIX64: /dev/rdsk/*vol or /dev/rdsk/node_wwn/*vol/* If HINT is already specified, ":HINT" can be omitted with the following command devices, and the command devices are retrieved from the already stored Inquiry information, which is not required to execute device scanning. HORCM_CMD #dev_name dev_name dev_name \\.\CMD CL1:/dev/rdsk/ \\.\CMD CL2 Basic Specification Specifies when an optional command device of Serial#30095 is used. \\.\CMD-30095:/dev/rdsk/ CCI software environment 2 19

48 Driver in the multi-path environment Specifies when an optional port is used as a command device for Serial#30095, LDEV#250. \\.\CMD :/dev/rdsk/ For full specification Specifies a command device for Serial#30095, LDEV#250:, which is connected to Port CL1-A, Host group#1. Other example \\.\CMD CL1:/dev/rdsk/ \\.\CMD CL2 \\.\CMD-30095:/dev/rdsk/c1 \\.\CMD-30095:/dev/rdsk/c2 (3) HORCM_DEV The device parameter (HORCM_DEV) defines the RAID storage system device addresses for the paired logical volume names. When the server is connected to two or more storage systems, the unit ID is expressed by port# extension. Each group name is a unique name discriminated by a server that uses the volumes, the attributes of the volumes (such as database data, redo log file, UNIX file), recovery level, etc. The group and paired logical volume names described in this item must reside in the remote server. The hardware SCSI/fibre port, target ID, and LUN as hardware components need not be the same. The following values are defined in the HORCM_DEV parameter: dev_group: Names a group of paired logical volumes. A command is executed for all corresponding volumes according to this group name. dev_name: Names the paired logical volume within a group (that is, name of the special file or unique logical volume). The name of paired logical volume must be different to the dev name in another group. Port#: Defines the RAID storage system port number of the volume that connects to the dev_name volume. The following "n" shows unit ID when the server is connected to two or more storage systems (for example, CL1-A1 = CL1-A in unit ID 1). If the "n" option is omitted, the unit ID is 0. The port is not case sensitive (for example, CL1-A= cl1-a= CL1-a= cl1-a). - Basic Option Option Option CL1 An Bn Cn Dn En Fn Gn Hn Jn Kn Ln Mn Nn Pn Qn Rn CL2 An Bn Cn Dn En Fn Gn Hn Jn Kn Ln Mn Nn Pn Qn Rn The following ports can be specified only for the 9900V: - Basic Option Option Option CL3 an bn cn dn en fn gn hn jn kn ln mn nn pn qn rn CL4 an bn cn dn en fn gn hn jn kn ln mn nn pn qn rn For 9900V, CCI supports four types of port names for host groups: 2 20 CCI software environment

49 Specifying the port name without a host group: CL1-A CL1-An, where n is the unit ID if there are multiple RAID storage systems Specifying the port name with a host group: CL1-A-g, where g is the host group CL1-An-g, where n-g is the host group g on CL1-A in unit ID=n The following ports can be specified for USP V/VM and TagmaStore USP/ TagmaStore NSC: - Basic Option Option Option CL5 an bn cn dn en fn gn hn jn kn ln mn nn pn qn rn CL6 an bn cn dn en fn gn hn jn kn ln mn nn pn qn rn CL7 an bn cn dn en fn gn hn jn kn ln mn nn pn qn rn CL8 an bn cn dn en fn gn hn jn kn ln mn nn pn qn rn CL9 an bn cn dn en fn gn hn jn kn ln mn nn pn qn rn CLA an bn cn dn en fn gn hn jn kn ln mn nn pn qn rn CLB an bn cn dn en fn gn hn jn kn ln mn nn pn qn rn CLC an bn cn dn en fn gn hn jn kn ln mn nn pn qn rn CLD an bn cn dn en fn gn hn jn kn ln mn nn pn qn rn CLE an bn cn dn en fn gn hn jn kn ln mn nn pn qn rn CLF an bn cn dn en fn gn hn jn kn ln mn nn pn qn rn CLG an bn cn dn en fn gn hn jn kn ln mn nn pn qn rn Target ID: Defines the SCSI/fibre target ID (TID) number of the physical volume on the specified port. LU#: Defines the SCSI/fibre logical unit number (LU#) of the physical volume on the specified target ID and port. Note: In case of fibre channel, if the TID and LU# displayed on the system are different than the TID on the fibre address conversion table, then you must use the TID and LU# indicated by the raidscan command in the CCI configuration file. MU# for ShadowImage (HOMRCF): Defines the mirror unit number (0-2) to use the redundant mirror for the identical LU on the ShadowImage. If this number is omitted, it is assumed to be zero (0). The cascaded mirroring of the S-VOL is expressed as virtual volumes using the mirror descriptors (MU#1-2) in the configuration definition file. The MU#0 of a mirror descriptor is used for connection of the S-VOL. The mirror descriptor (MU#0-2) can be used in ShadowImage and Copy-on-Write Snapshot. MU#3-63 can be used in Copy-on-Write Snapshot only. Feature SMPL P-VOL S-VOL MU#0-2 MU#3-63 MU#0-2 MU#3-63 MU# 0 MU#1-63 ShadowImage Valid Not valid Valid Not valid Valid Not valid Copy-on-Write Valid Valid Valid Valid Valid Not valid Snapshot CCI software environment 2 21

50 MU#for TrueCopy/UR : Defines the mirror unit number (0-3) to use the redundant mirror for the identical LU on TrueCopy/UR. If this number is omitted, it is assumed to be zero (0). The UR mirror description is described in the MU# column by adding "h" in order to identify identical LUs as the mirror descriptor for UR. The MU# for TrueCopy must be specified only "0". TrueCopy has only one mirror description, but UR has four mirrors as shown below. Feature MU#0 SMPL P-VOL S-VOL MU#h1 - h3 MU#0 MU#h1 - h3 MU#0 MU#h1 - h3 TrueCopy Valid Not valid Valid Not valid Valid Not valid UR Valid Valid Valid Valid Valid Valid (4) HORCM_INST The instance parameter (HORCM_INST) defines the network address (IP address) of the remote server (active or standby). It is used to view or change the status of the paired volume in the remote server (active or standby). When the primary volume is shared by two or more servers, there are two or more remote servers using the secondary volume. Thus, it is necessary to describe the addresses of all of these servers. The following values are defined in the HORCM_INST parameter: dev_group: The server name described in dev_group of HORC_DEV. ip_address: The network address of the specified remote server. service: The port name assigned to the HORCM communication path (registered in the /etc/services file). If a port number is specified instead of a port name, the port number will be used. When HORCM has two or more network addresses on different subnets for communication, the ip_address of HORCM_MON must be NONE. This configuration for multiple networks can be found using the raidqry -r <group> command option on each host. The current HORCM network address can be changed using horcctl -NC <group> on each host CCI software environment

51 Figure 2-13 Configuration for multiple networks (5) HORCM_LDEV The HORCM_LDEV parameter is used for specifying stable LDEV# and Serial# as the physical volumes corresponding to the paired logical volume names. Each group name is unique and typically has a name fitting its use (for example, database data, Redo log file, UNIX file). The group and paired logical volume names described in this item must also be known to the remote server. dev_group: This parameter is the same as HORCM_DEV parameter. dev_name: This parameter is the same as HORCM_DEV parameter. MU#: This parameter is the same as HORCM_DEV parameter. Serial#: This parameter is used to specify the serial number of RAID box. For VSP G1000, add a 3 at the beginning of the serial number. For example, for serial number 12345, enter CU:LDEV(LDEV#): This parameter is used to describe the LDEV number in the RAID storage system and supports three types of format as LDEV#. #dev_group dev_name Serial# CU:LDEV(LDEV#) MU# oradb dev :40 0 oradb dev :41 0 Specifying "CU:LDEV" in hex used by SVP or Web console Example for LDEV# : 04 CCI software environment 2 23

52 Specifying "LDEV" in decimal used by the inqraid command of CCI Example for LDEV# Specifying "LDEV" in hex used by the inqraid command of CCI Example for LDEV# 260 0x104 Note: The HORCM_LDEV format can only be used on the TagmaStore USP/TagmaStore NSC. LDEV# will be converted to "Port#, Targ#, Lun#" mapping to this LDEV internally, because the RAID storage system needs to specify "Port#, Targ#, Lun#" for the target device. This feature is TagmaStore USP/TagmaStore NSC microcode dependent; if HORCM fails to start, HORCM_DEV needs to be used. (6) HORCM_LDEVG The HORCM_LDEVG parameter defines the device group information that the CCI instance reads. For details about device group, see LDEV grouping function on page The following values are defined. Copy group: specifies a name of copy group. This is equivalent to the dev_group of HORCM_DEV and HORCM_LDEV parameters. CCI operates by using the information defined here. ldev_group: Specifies a name of device group that the CCI instance reads. Serial#: Specifies a storage system serial number. For VSP G1000, add a 3 at the beginning of the serial number. For example, for serial number 12345, enter HORCM_LDEVG #Copy_Group ldev_group Serial# ora grp (7) HORCM_INSTP The HORCM_INSTP parameter is used when specifying a path ID for the link of TrueCopy as well as HORCM_INST parameter. You can specify from 1 to 255 for the path ID. If you do not specify the Path ID, the behavior is the same as when 'HORCM_INST' is used. HORCM_INSTP dev_group ip_address service pathid VG01 HSTA horcm 1 VG02 HSTA horcm 2 Note: The path ID can be specified at TrueCopy, Universal Replicator, and Universal Replicator for Mainframe. However, the path ID cannot be specified at UR/URz when connecting USP V/VM and USP/NSC. The same path ID must be specified between the site of P-VOL and S-VOL because the path ID is used at the paircreate command CCI software environment

53 (8) HORCM_ALLOW_INST The HORCM_ALLOW_INST parameter is used to restrict the users using the virtual command device. The allowed IP addresses and port numbers are as follows. For IPv4 HORCM_ALLOW_INST #ip_address service For IPv6 HORCM_ALLOW_INST #ip_address service fe80::209:6bff:febe:3c Note: If CCI clients not defined HORCM_ALLOW_INST, HORCM instance starting up is rejected by SCSI check condition (SKEY=0x05, ASX=0xfe) and CCI cannot be started up. Configuration definition for cascading volume pairs The CCI software (HORCM) is capable of keeping track of up to seven pair associations per LDEV (1 for TrueCopy/UR, 3 for UR, 3 for ShadowImage/ Copy-on-Write Snapshot, 1 for Copy-on-Write Snapshot). By this management, CCI can be assigned to seven groups per actual LU that is described in the configuration definition file. Figure 2-14 Mirror descriptors and group assignment Configuration file and mirror descriptors The group name and MU# described in the HORCM_DEV parameter of a configuration definition file are assigned the corresponding mirror descriptors, as outlined in Table 2-3 Mirror descriptors and group assignments on page "Omission of MU#" is handled as MU#0, and the specified group is registered to MU#0 on ShadowImage and TrueCopy. Also, the MU# that is noted for HORCM_DEV in Table 2-3 Mirror descriptors and group assignments on page 2-26 reflects a random numbering sequence (for example, 2, 1, 0). CCI software environment 2 25

54 Table 2-3 Mirror descriptors and group assignments HORCM_DEV parameter in configuration file TC/ UR MU#0 SI SI (Snapshot) only MU#1-#2 (MU#3- #63) UR only MU#1- #3 HORCM_DEV #dev_group dev_name port# TargetID LU# MU# Oradb oradev1 CL1-D 2 1 HORCM_DEV #dev_group dev_name port# TargetID LU# MU# Oradb oradev1 CL1-D 2 1 Oradb1 oradev11 CL1-D Oradb2 oradev21 CL1-D HORCM_DEV #dev_group dev_name port# TargetID LU# MU# Oradb oradev1 CL1-D 2 1 Oradb1 oradev11 CL1-D Oradb2 oradev21 CL1-D Oradb3 oradev31 CL1-D HORCM_DEV #dev_group dev_name port# TargetID LU# MU# Oradb oradev1 CL1-D HORCM_DEV #dev_group dev_name port# TargetID LU# MU# Oradb oradev1 CL1-D Oradb1 oradev11 CL1-D Oradb2 oradev21 CL1-D HORCM_DEV #dev_group dev_name port# TargetID LU# MU# Oradb oradev1 CL1-D 2 1 Oradb1 oradev11 CL1-D Oradb2 oradev21 CL1-D 2 1 h1 Oradb3 oradev31 CL1-D 2 1 h2 Oradb4 oradev41 CL1-D 2 1 h3 oradev1 oradev1 - - oradev1 oradev1 oradev11 - oradev21 oradev1 oradev11 oradev21 - oradev31 - oradev oradev1 oradev11 oradev21 - oradev1 oradev11 - oradev21 oradev31 oradev41 Cascading connection and configuration files A volume of the cascading connection describes entity in a configuration definition file on the same instance, and classifies connection of volume through the mirror descriptor. In case of TrueCopy/ShadowImage cascading connection, too, the volume entity describes to a configuration definition file on the same instance. The following figure shows an example of this CCI software environment

55 ShadowImage Figure 2-15 ShadowImage cascade connection and configuration file Since ShadowImage is a mirrored configuration within one storage system, it can be described as a volume of the cascading connection according to two configuration definition files. For a ShadowImage-only cascading connection, the specified group is assigned to the mirror descriptor (MU#) of ShadowImage, specifically defining "0" as the MU# for ShadowImage. Figure 2-16 Pairdisplay on HORCMINST0 on page Figure 2-18 Pairdisplay on HORCMINST0 on page 2-28 show ShadowImage cascading configurations and the pairdisplay information for each configuration. CCI software environment 2 27

56 Figure 2-16 Pairdisplay on HORCMINST0 Figure 2-17 Pairdisplay on HORCMINST1 Figure 2-18 Pairdisplay on HORCMINST CCI software environment

57 Cascading connections for TrueCopy and ShadowImage The cascading connections for TrueCopy/ShadowImage can be set up by using three configuration definition files that describe the cascading volume entity in a configuration definition file on the same instance. The mirror descriptor of ShadowImage and TrueCopy definitely describe "0" as MU#, and the mirror descriptor of TrueCopy does not describe "0" as MU#. Figure 2-19 TrueCopy/ShadowImage cascading connection and configuration file Figure 2-20 Pairdisplay for TrueCopy on HOST1 on page 2-30 through Figure 2-23 Pairdisplay for ShadowImage on HOST2 (HORCMINST0) on page 2-31 show TrueCopy/ShadowImage cascading configurations and the pairdisplay information for each configuration. CCI software environment 2 29

58 Figure 2-20 Pairdisplay for TrueCopy on HOST1 Figure 2-21 Pairdisplay for TrueCopy on HOST2 (HORCMINST) 2 30 CCI software environment

59 Figure 2-22 Pairdisplay for ShadowImage on HOST2 (HORCMINST) CCI software files Figure 2-23 Pairdisplay for ShadowImage on HOST2 (HORCMINST0) The CCI software consists of files supplied with the software, log files created internally, and files created by the user. These files are stored on the local disk in the server machine. CCI files supplied with the software on page 2-32 CCI log and trace files on page 2-35 User environment variable on page 2-44 CCI software environment 2 31

60 CCI files supplied with the software CCI files for UNIX-based systems on page 2-32 CCI files for Windows-based systems on page 2-33 CCI files for OpenVMS-based systems on page 2-35 CCI files for UNIX-based systems Title File name Command name Mode User*1 Group HORCM /etc/horcmgr horcmd 0544 root sys HORCM_CONF /HORCM/etc/horcm.conf root sys Takeover /usr/bin/horctakeover horctakeover 0544 root sys Accessibility check /usr/bin/paircurchk paircurchk 0544 root sys Pair generation /usr/bin/paircreate paircreate 0544 root sys Pair splitting /usr/bin/pairsplit pairsplit 0544 root sys Pair /usr/bin/pairresync pairresync 0544 root sys resynchronization Event waiting /usr/bin/pairevtwait pairevtwait 0544 root sys Error notification /usr/bin/pairmon pairmon 0544 root sys Volume check /usr/bin/pairvolchk pairvolchk 0544 root sys Pair configuration /usr/bin/pairdisplay pairdisplay 0544 root sys confirmation RAID scanning /usr/bin/raidscan raidscan 0544 root sys RAID activity /usr/bin/raidar raidar 0544 root sys reporting Connection /usr/bin/raidqry raidqry 0544 root sys confirming Trace control /usr/bin/horcctl horcctl 0544 root sys HORCM activation /usr/bin/horcmstart.sh horcmstart.sh 0544 root sys script HORCM shutdown /usr/bin/horcmshutdown.sh horcmshutdown.sh 0544 root sys script Connection /HORCM/usr/bin/inqraid root sys confirming Synchronous /usr/bin/pairsyncwait pairsyncwait 0544 root sys waiting Configuration setting and confirming command /HORCM/usr/bin/raidcfg raidcfg 0544 root sys Text filtering /HORCM/usr/bin/rmawk rmawk 0544 root sys DB Validator /usr/bin/raidvchkset raidvchkset 0544 root sys setting DB Validator confirmation DB Validator confirmation /usr/bin/raidvchkdsp raidvchkdsp 0544 root sys /usr/bin/raidvchkscan raidvchkscan 0544 root sys 2 32 CCI software environment

61 Title File name Command name Mode User*1 Group Storage Replication Adapter Configuration setting command A file for management A file for management A file for management /HORCM/usr/bin/rmsra rmsra 0544 root sys HORCM/usr/bin/raidcom raidcom 0544 root sys HORCM/etc/ Raidcom_Dic_Raid_RM_Patch.txt HORCM/etc/ Raidcom_Help_Raid_RM.txt HORCM/etc/ Raidcom_Dic_Raid_RM.txt root sys root sys root sys For information and instructions on changing the UNIX user for the CCI software, please see the Command Control Interface Installation and Configuration Guide. CCI files for Windows-based systems Title File name Command name HORCM \HORCM\etc\horcmgr.exe horcmd HORCM_CONF \HORCM\etc\horcm.conf - Takeover \HORCM\etc\horctakeover.exe horctakeover Accessibility check \HORCM\etc\paircurchk.exe paircurchk Pair generation \HORCM\etc\paircreate.exe paircreate Pair split \HORCM\etc\pairsplit.exe pairsplit Pair re-synchronization \HORCM\etc\pairresync.exe pairresync Event waiting \HORCM\etc\pairevtwait.exe pairevtwait Error notification \HORCM\etc\pairmon.exe pairmon Volume checking \HORCM\etc\pairvolchk.exe pairvolchk Pair configuration confirmation \HORCM\etc\pairdisplay.exe pairdisplay RAID scanning \HORCM\etc\raidscan.exe raidscan RAID activity reporting \HORCM\etc\raidar.exe raidar Connection confirmation \HORCM\etc\raidqry.exe raidqry Trace control \HORCM\etc\horcctl.exe horcctl HORCM activation script \HORCM\etc\horcmstart.exe horcmstart HORCM shutdown script \HORCM\etc\horcmshutdown.exe horcmshutdown Synchronous waiting \HORCM\etc\pairsyncwait.exe pairsyncwait Connection confirmation \HORCM\etc\inqraid.exe inqraid Configuration setting and \HORCM\Tool\mkconf.exe mkconf confirming command Text filtering \HORCM\Tool\rmawk.exe rmawk Oracle Validation setting \HORCM\etc\raidvchkset.exe raidvchkset Oracle Validation confirmation \HORCM\etc\raidvchkdsp.exe raidvchkdsp CCI software environment 2 33

62 Title File name Command name Oracle Validation confirmation \HORCM\etc\raidvchkscan.exe raidvchkscan Configuration setting command \HORCM\etc\raidcom.exe raidcom A file for management \HORCM\etc\Raidcom_Dic_Raid_RM_Patch.txt - A file for management \HORCM\etc\Raidcom_Help_Raid_RM.txt - A file for management \HORCM\etc\Raidcom_Dic_Raid_RM.txt - Tool \HORCM\Tool\chgacl.exe chgacl Tool \HORCM\Tool\svcexe.exe svcexe Sample script for svcexe \HORCM\Tool\HORCM0_run.txt - Tool \HORCM\Tool\TRCLOG.bat TRCLOG Storage Replication Adapter \HORCM\etc\rmsra.exe rmsra Takeover \HORCM\usr\bin\horctakeover.exe horctakeover Accessibility check \HORCM\usr\bin\paircurchk.exe paircurchk Pair generation \HORCM\usr\bin\paircreate.exe paircreate Pair split \HORCM\usr\bin\pairsplit.exe pairsplit Pair re-synchronization \HORCM\usr\bin\pairresync.exe pairresync Event waiting \HORCM\usr\bin\pairevtwait.exe pairevtwait Volume check \HORCM\usr\bin\pairvolchk.exe pairvolchk Synchronous waiting \HORCM\usr\bin\pairsyncwait.exe pairsyncwait Pair configuration confirmation \HORCM\usr\bin\pairdisplay.exe pairdisplay RAID scanning \HORCM\usr\bin\raidscan.exe raidscan Connection confirmation \HORCM\usr\bin\raidqry.exe raidqry Oracle Validation setting \HORCM\usr\bin\raidvchkset.exe raidvchkset Oracle Validation confirmation \HORCM\usr\bin\raidvchkdsp.exe raidvchkdsp Oracle Validation confirmation \HORCM\usr\bin\raidvchkscan.exe raidvchkscan Configuration setting and confirming command \HORCM\usr\bin\raidcfg.exe raidcfg Note: The \HORCM\etc\ commands are used from the console window. If these commands are executed without an argument, the interactive mode will start up. The \HORCM\usr\bin commands have no console window, and can therefore be used from the application. The \HORCM\usr\bin commands do not support the directory mounted volumes in subcommands. \HORCM\Tool\TRCLOG.bat is a troubleshooting tool. This tool is not usually used. \HORCM\etc\rmsra.exe is the binary data used for cooperation with VMware. This is used directly by VMware, not usually used by users CCI software environment

63 CCI files for OpenVMS-based systems Title File name Command name User HORCM $ROOT:[HORCM.etc]horcmgr.exe horcmd sys HORCM_CONF $ROOT:[HORCM.etc]horcm.conf - sys Takeover $ROOT:[HORCM.usr.bin]horctakeover.exe horctakeover sys Volume accessibility check $ROOT:[HORCM.usr.bin]paircurchk.exe paircurchk sys Pair generation $ROOT:[HORCM.usr.bin]paircreate.exe paircreate sys Pair splitting $ROOT:[HORCM.usr.bin]pairsplit.exe pairsplit sys Pair re-synchronization $ROOT:[HORCM.usr.bin]pairresync.exe pairresync sys Event waiting $ROOT:[HORCM.usr.bin]pairevtwait.exe pairevtwait sys Error notification $ROOT:[HORCM.usr.bin]pairmon.exe pairmon sys Volume checking $ROOT:[HORCM.usr.bin]pairvolchk.exe pairvolchk sys Pair config. confirmation $ROOT:[HORCM.usr.bin]pairdisplay.exe pairdisplay sys RAID scan $ROOT:[HORCM.usr.bin]raidscan.exe raidscan sys RAID activity report $ROOT:[HORCM.usr.bin]raidar.exe raidar sys Connection confirmation $ROOT:[HORCM.usr.bin]raidqry.exe raidqry sys Trace control $ROOT:[HORCM.usr.bin]horcctl.exe horcctl sys HORCM activation script $ROOT:[HORCM.usr.bin]horcmstart.exe horcmstart.sh sys HORCM shutdown script $ROOT:[HORCM.usr.bin]horcmshutdown.exe horcmshutdown.sh sys Connection confirmation $ROOT:[HORCM.usr.bin]inqraid.exe - sys Synchronous waiting $ROOT:[HORCM.usr.bin]pairsyncwait.exe pairsyncwait sys Configuration file making $ROOT:[HORCM.usr.bin]mkconf.exe - sys Text filtering $ROOT:[HORCM.usr.bin]rmawk.exe - sys Database Validator setting $ROOT:[HORCM.usr.bin]raidvchkset.exe raidvchkset sys DB Validator confirmation $ROOT:[HORCM.usr.bin]raidvchkdsp.exe raidvchkdsp sys DB Validator confirmation $ROOT:[HORCM.usr.bin]raidvchkscan.exe raidvchkscan sys Storage Replication Adapter $ROOT:[HORCM.usr.bin]rmsra.exe rmsra sys Sample file for horcmstart $ROOT:[HORCM]loginhorcm*.com - sys Sample file for horcmstart $ROOT:[HORCM]runhorcm*.com - sys Note: $ROOT is defined as SYS$POSIX_ROOT. $POSIX_ROOT is necessary when using C RTL. The user name for OpenVMS is "System". CCI log and trace files The CCI software (HORCM) maintains internal startup log files, execution log files, and trace files that can be used to identify the causes of errors and to keep records of the status transition history of the paired volumes. CCI log files on page 2-36 CCI trace files on page 2-38 CCI software environment 2 35

64 CCI log files CCI trace control command on page 2-38 Command logging for audit on page 2-39 HORCM logs are classified into startup logs and execution logs. The startup logs contain data on errors that occur before HORCM becomes ready to provide services. Thus, if HORCM fails to start up due to improper environment setting, refer to the startup logs to resolve the problem. The HORCM execution logs (error log, trace, and core files) contain data on errors that are caused by software or hardware problems. These logs contain internal error data that does not apply to any user settings, therefore, you do not need to refer to the HORCM execution logs. When an error occurs in execution of a command, data on the error is collected in the command log file. Users may refer to the command log file if a command execution error occurs. The following figure shows a graphical representation of the CCI log and trace files within the CCI configuration environment. Figure 2-24 Logs and traces The startup log, error log, trace, and core files are stored as shown in Table 2-4 Log file names and locations on page Specify the directories for the HORCM and command log files using the HORCM_LOG and HORCC_LOG environment variables as shown in Table 2-5 Environment variables for log 2 36 CCI software environment

65 directories on page If it is not possible to create the log files, or if an error occurs before the log files are created, the error logs are output in the system log file. If the HORCM activation fails, the system administrator should check the system log file and activation log, identify the error cause, and take the proper action. The system log file for UNIX-based systems is the syslog file. The system log file for Windows-based systems is the event log file. Table 2-4 Log file names and locations File UNIX-based systems Windows-based systems Startup log Error log Trace Core HORCM startup log: $HORCM_LOG/horcm_HOST.log Command log: $HORCC_LOG/ horcc_host.log $HORCC_LOG/horcc_HOST.oldlog HORCM error log: $HORCM_LOG/horcmlog_HOST/ horcm.log HORCM trace: $HORCM_LOG/horcmlog_HOST/ horcm_pid.trc Command trace: $HORCM_LOG/horcmlog_HOST/ horcc_pid.trc HORCM core: $HORCM_LOG/core_HOST_PID/core Command core: $HORCM_LOG/core_HOST_PID/core HORCM startup log: $HORCM_LOG\horcm_HOST_log.txt Command log: $HORCC_LOG\horcc_HOST_log.txt $HORCC_LOG\horcc_HOST_oldlog.txt HORCM error log: $HORCM_LOG\horcmlog_HOST\horcm_log.txt HORCM trace: $HORCM_LOG\horcmlog_HOST\horcm_PID_trc.txt Command trace: $HORCM_LOG\horcmlog_HOST\horcc_PID_trc.txt HORCM core: $HORCM_LOG\core_HOST_PID\core Command core: $HORCM_LOG\core_HOST_PID\core Note: HOST denotes the host name of the corresponding machine. PID denotes the process ID of that machine. The location of the directory containing the log file depends on your command execution environment and the HORCM execution environment. The command trace file and core file reside together under the directory specified in the HORCM execution environment. A directory specified using the environment variable HORCM_LOG is used as the log directory in the HORCM execution environment. If no directory is specified, the directory / tmp is used. A directory specified using the environment variable HORCC_LOG is used as the log directory in the command execution environment. If no directory is specified, the directory /HORCM/log* is used (* = instance number). A nonexistent directory may be specified as a log directory using the environment variable. CCI software environment 2 37

66 Table 2-5 Environment variables for log directories Directory name $HORCM_LOG $HORCC_LOG Definition A directory specified using the environment variable HORCM_LOG. The HORCM log file, trace file, and core file as well as the command trace file and core file are stored in this directory. If no environment variable is specified, "/HORCM/log/curlog" is used. A directory specified using the environment variable HORCC_LOG. The command log file is stored in this directory. If no environment variable is specified, the directory "/HORCM/log*" is used (* is the instance number). While the HORCM is running, the log files are stored in the $HORCM_LOG directory shown in (a). When the HORCM starts up, the log files created in the operation are stored automatically in the $HORCM_LOGS directory shown in (b). a. HORCM log file directory in operation $HORCM_LOG = /HORCM/log*/curlog (* is instance number) b. HORCM log file directory for automatic storing $HORCM_LOGS = /HORCM/log*/tmplog (* is instance number) CCI trace files The command trace file is used for maintenance aiming at troubleshooting. It is not created normally. If a cause of an error cannot be identified using the log file, the environment variables or trace control commands with trace control parameters are issued to start tracing and the trace file is created. The trace control parameters include trace level, file size, mode, etc. More detailed tracing is enabled by increasing the trace level. Tracing is made in wraparound within the range of the file size. HORCM makes the trace file according to the trace level specified in the HORCM startup shell script set to activate the HORCM. CCI trace control command The trace control command (one of the HORCM control commands) sets or changes the trace control parameters. This command is used for troubleshooting and maintenance. If no trace control parameters can be specified using the environment variables in your command execution environment, it is possible to change the trace control parameters into the global parameters using this command. Table 2-6 Trace command parameters on page 2-38 lists and describes the parameters of the trace control command. Table 2-6 Trace command parameters Parameter Function Trace level parameter Specifies the trace level, range = 0 to 15. Trace size parameter Specifies the trace file size in KB. Trace mode parameter Specifies the buffer mode or non-buffer mode for writing data in the trace file. Trace type parameter Specifies the trace type defined internally. Trace change instruction Specifies the command or CCI instance for which the trace control parameters are changed CCI software environment

67 Command logging for audit Logging other than raidcom command on page 2-39 Logging raidcom command on page 2-41 Logging other than raidcom command This section explains the logging other than the raidcom command described in Logging raidcom command on page CCI supports command logging, this logging function cannot be used for auditing the script issuing the command. Thus, CCI supports the function logging the result of the command executions by expanding the current logging. This function has the following control parameters. $HORCC_LOGSZ variable This variable is used to specify a maximum size (in units of KB) and normal logging for the current command. /HORCM/log*/horcc_HOST.log file is moved to /HORCM/log*/horcc_HOST.oldlog file when reaching in the specified maximum size. If this variable is not specified or specified as 0, it is same as the current logging for only command error. This variable is able to define to the environment variable and/or horcc_host.conf as discussed below. For example setting 2MB size: HORCC_LOGSZ=2048 Export HORCC_LOGSZ /HORCM/log*/horcc_HOST.conf file This file is used to describe HORCC_LOGSZ variable and the masking variable for logging. If the HORCC_LOGSZ as the environment variable is not specified, then HORCC_LOGSZ variable of this file is used. If both variable is not specified, then it is same as the current logging for only command error. HORCC_LOGSZ variable This variable must be described as follows: HORCC_LOGSZ=2048 The masking variable This variable is used to mask (disable) the logging by specifying a condition of the command and returned value (except inqraid or EX_xxx error code). This variable is valid for NORMAL exit. If executing the pairvolchk command repeatedly at every interval (30 seconds), logging of this command may not be wanted. Therefore, you can mask it by specifying HORCC_LOGSZ=0 as shown below, and you may need to change your scripts if tracing is ON. Example of masking pairvolchk on a script: Export HORCC_LOGSZ=0 Pairvolchk -g xxx -s Unset HORCC_LOGSZ The masking feature is to enable the tracing without changing their scripts. And this feature is available for all CCI commands (except inqraid or EX_xxx error code). CCI software environment 2 39

68 For example, if you want to mask pairvolchk (returns 22) and raidqry, specify the following: pairvolchk=22 raidqry=0 You can track script performance, and then decide to mask by auditing the command logging file, as needed. Relationship between an environment variable and horcc_host.conf Logging depends on the $HORCC_LOGSZ environment variable and/or the HORCC_HOST.conf file as shown below. $HORCC_LOGSZ HORCC_HOST.conf Performing =value Any (does not matter) Tracing within this APP =0 NO tracing within this APP Unspecified HORCC_LOGSZ=valu Global tracing within this CCI instance e HORCC_LOGSZ=0 NO global tracing within this CCI instance Unspecified or nonexistent Examples for execution /HORCM/log* directory Use the default value (0) The same as the current logging for only command error [root@raidmanager log9]# ls l total 16 drwxr-xr-x 3 root root 4096 Oct 27 17:33 curlog -rw-r--r-- 1 root root 3936 Oct 27 17:36 horcc_raidmanager.log -rw-r--r-- 1 root root Oct 27 17:29 horcc_raidmanager.oldlog -rw-r--r-- 1 root root 46 Oct 27 17:19 horcc_raidmanager.conf drwxr-xr-x 3 root root 4096 Oct 27 17:19 tmplog /HORCM/log*/horcc_HOST.log file COMMAND NORMAL : EUserId for HORC : root (0) Tue Nov 1 12:21: CMDLINE : pairvolchk ss g URA 12:21:54-2d27f [pairvolchk][exit(32)] COMMAND NORMAL : EUserId for HORC : root (0) Thu Oct 27 17:36: CMDLINE : raidqry l 17:36:32-3d83c [raidqry][exit(0)] COMMAND ERROR : EUserId for HORC : root (0) Thu Oct 27 17:31: CMDLINE : pairdisplay g UR 17:31:28-9a ERROR:cm_sndrcv[rc < 0 from HORCM] 17:31:28-9b0a [pairdisplay][exit(239)] [EX_ENOGRP] No such group [Cause ]:The group name which was designated or the device name doesn't exist in the configuration file, or the network address for remote communication doesn't exist. [Action]:Please confirm if the group name exists in the configuration file of the local and remote host /HORCM/log*/horcc_HOST.conf file 2 40 CCI software environment

69 Logging raidcom command # For Example HORCC_LOGSZ=2048 #The masking variable #This variable is used to disable the logging by the command and exit code. #For masking below log pairvolchk returned '32'(status is SVOL_COPY) #COMMAND NORMAL : EUserId for HORC : root (0) Tue Nov 1 12:21: #CMDLINE : pairvolchk ss g URA #12:21:54-2d27f [pairvolchk][exit(32)] pairvolchk=32 pairvolchk=22 The history of performing raidcom command can be stored in syslog server by outputting it to the syslog file. Since the information of what command was performed by who and when are recorded on the syslog file, this is available to use for audit log. Output the syslog file by using syslog service on the host OS. For details, refer to the host OS manual. Caution: The packet loss occurs on the syslog because the syslog uses UDP communication. The log is also lost when the server to be received the syslog is down because the server does not have a function to store the data until it recovered. If you want to record the same log at the client side by considering the lost of syslog at the syslog server, refer to the output setting of the syslog file. This syslog files are not deleted automatically. Delete unnecessary files accordingly, or make run the log rotation by installing such as the logrotate service separately. The conditions to support the output of syslog file The conditions to support this function are explained in the following: Supported OS This function is supported only when the OS of the host is one of the following (Windows is out of support): Solaris 2.5 Solaris 10/x86 HP-UX 10.20/11.0/11.2x AIX 4.3 Red Hat Linux 6.0, 7.0, 8.0 AS/ES 2.1, 3.0, 4.0, 5.0 AS/ES 2.1, 3.0 Update2, 4.0, 5.0 on EM64T / IA641 Target command The following shows the raidcom command that is target to be output on the syslog file. CCI software environment 2 41

70 Setting commands raidcom get command status Authentication commands (performing the authentication command at the prompt also becomes the target.) However, if the command is not issued to the DKC by detecting the raidcom command execution error beforehand, the command becomes out of target even if it falls under the above items. Output setting for the syslog file A syslog file is output when "1" is set on the RAIDCOM_SYSLOG of environment variables. The syslog file is not output at the stage of initial setting. How to set the syslog.conf The contents that can be set on the syslog.conf for the environment setting may vary in each OS. However, set basically according to the syslog.conf described in the following: Setting example (It may vary by the host OS) Client side (extracts) user.info raidcomuser.err Server side (extracts) user.info raidcomuser.err raidcom.err /var/log/ /var/log/ /var/log/ You can record the same log at the client side by considering the lost of syslog at the syslog server. In this case, add the following settings. facility:user level:info/err ("info" for the normal command operation; "err" for the abnormal command operation.) Syslog file display information Three kinds of information for one raidcom command are output on the syslog file. Title row (first row) Command row (second row) Result rows (3-132 rows): the number of rows changes depending on the issuing command CCI software environment

71 Table 2-7 Display information of the title row Item Output example Syslog fixed output part (Including the host name) Jun 27 10:15:13 rmsolx86 raidcom: [ID user.info] *It varies depending on the host OS. Process ID PID:1234 Command status COMMAND NORMAL or COMMAND ERROR Separation : User name Title EUserId for HORC : User name of the host root (user ID) (0) Time that performed Wed Jun 27 10:15: raidcom Table 2-8 Display information of the command row Item Syslog fixed output part (Including the host name) Process ID Title for performed command Performed command Output example Jun 27 10:15:13 rmsolx86 raidcom: [ID user.info] *It varies depending on the host OS. PID:1234 CMDLINE: raidcom modify ldev -ldev_id status nml Table 2-9 Display information of the result rows Item Syslog fixed output part (Including the host name) Process ID [raidcom] Rows for the error information Result of get_command_status Rows for the returned values of a command Output example Jun 27 10:15:13 rmsolx86 raidcom: [ID user.info] *It varies depending on the host OS. PID:1234 [raidcom] [EX_CMDRJE] An order to the control/command device was rejected It was rejected due to SKEY=0x05, ASC=0x26, ASCQ=0x00, SSB=0x2E11,0x2205 on Serial#(64568) HANDLE SSB1 SSB2 ERR_CNT Serial# Description 00c [exit(0)] Display example (It may vary depending on the host OS.) Logs when the normal operation Aug 24 12:24:37 raidmanager raidcom: PID:06864 COMMAND NORMAL : EUserID for HORC : root(0) Fri Aug 24 12:24: Aug 24 12:24:37 raidmanager raidcom: PID:06864 CMDLINE : raidcom get command_status -ldev_id 0001 Aug 24 12:24:37 raidmanager raidcom: PID:06864 [raidcom] HANDLE CCI software environment 2 43

72 SSB1 SSB2 ERR_CNT Serial# Description Aug 24 12:24:37 raidmanager raidcom: PID:06864 [raidcom] 00c Aug 24 12:24:37 raidmanager raidcom: PID:06864 [raidcom] [exit(0)] Logs when the abnormal operation User-created files Aug 24 12:24:27 raidmanager raidcom: PID:06857 COMMAND ERROR : EUserID for HORC : root(0) Fri Aug 24 12:24: Aug 24 12:24:27 raidmanager raidcom: PID:06857 CMDLINE : raidcom get command_status Aug 24 12:24:27 raidmanager raidcom: PID:06857 [raidcom] User for Serial#[64568] : user1234 Aug 24 12:24:27 raidmanager raidcom: PID:06857 [raidcom] User authentication has failed on Serial#(64568). Aug 24 12:24:27 raidmanager raidcom: PID:06857 [raidcom] [EX_ENAUTH] Authentication failed with User Aug 24 12:24:27 raidmanager raidcom: PID:06857 [raidcom] [exit(202)] CCI supports scripting to provide automated and unattended copy operations. A CCI script contains a list of CCI commands that describes a series of TrueCopy and/or ShadowImage operations. The scripted commands for UNIX-based platforms are defined in a shell script file. The scripted commands for Windows-based platforms are defined in a text file. The host reads the script file and sends the commands to the command device to execute the TrueCopy/ShadowImage operations automatically. The CCI scripts are: HORCM startup script (horcmstart.sh, horcmstart.exe). A script that starts HORCM (/etc/horcmgr), sets environment variables as needed (for example, HORCM_CONF, HORCM_LOG, HORCM_LOGS), and starts HORCM. HORCM shutdown script. (horcmshutdown.sh, horcmshutdown.exe): A script for stopping the HORCM (/etc/ horcmgr). HA control script. A script for executing takeover processing automatically when the cluster manager (CM) detects a server error. When constructing the HORCM environment, the system administrator should make a copy of the horcm.conf file. The copied file should be set according to the system environment and registered as the following file (* is the instance number): UNIX systems: /etc/horcm.conf or /etc/horcm*.conf Windows systems:%windir%\horcm.conf or %windir%\horcm*.conf User environment variable When HORCM or command is invoked, environment variable can be specified CCI software environment

73 3 CCI functions This chapter describes the CCI functions. Command execution using in-band and out-of-band methods Connecting to CCI server already connected by In-Band method using Out-of-Band method User authentication Command operation authority and user authentication Relation between resource groups and command operations Resource lock function Command execution modes Resource location and parameter LDEV grouping function Pair operations with mainframe volumes Global virtualization function (VSP G1000 only) CCI functions 3 1

74 Command execution using in-band and out-of-band methods The methods of executing commands provided by CCI can be classified into the in-band and out-of-band methods. In-band method. This method transfers a command from the client or the server to the command device of the storage system via fibre and executes a CCI operation instruction. Out-of-band method. This method transfers a command from the client or the server to the virtual command device in the SVP via LAN, assigning a CCI operation instruction to the storage system, and executes it. If many commands are issued in a short period of time, for example issuing commands in the configuration in cooperation with VMware Site Recovery Manager (SRM), or from pre-existing scripts, the command response may slow. In this case, issuing commands using the In-Band method is recommended. Out-of-band operations are supported on the Virtual Storage Platform and later storage systems. When executing a command using the in-band and out-of-band methods, a command device or a virtual command device is set in a configuration definition file as shown in the following figure. For the out-of-band method, the IP address of the SVP is specified in the configuration definition file. The following figure shows a system configuration example and a setting example of a command device and a virtual command device using the inband and out-of-band methods. 3 2 CCI functions

75 Figure 3-1 System configuration example and setting example of command device and virtual command device by in-band and out-ofband methods To set these two methods, a command device or a virtual command device must be set to HORCM_CMD of a configuration definition file. Connecting to CCI server already connected by In-Band method using Out-of-Band method In Out-of-Band method, CCI server port can also be specified as a virtual command device. For this reason, CCI server which connected to a storage system in In-Band method can be connected in Out-of-Band method. If a CCI server is specified as a virtual command device, it provides a better performance than Out-of-Band method specified SVP as a virtual command device. CCI functions 3 3

76 Hardware requirements CCI uses SCSI path through driver to issue I/O for command device. To use CCI server port as virtual command device, the virtual command device interface needs to be converted to the actual SCSI path through interface. Following is the environment for using CCI server port as a virtual command device. CCI server which can set virtual command devices CCI support platform except Tru64UNIX and the environment can be used SCSI path through driver Client PC which can issue commands to virtual command devices It must be CCI support platform. Windows client such a Windows XP can be used as well. Initiator port Initiator port is required. Following is the default port number. If not specified the instance number: If specified instance number (X): X + 1 If you change the default port number, use following environment variables. $HORCM_IPSCPORT=<services>* * <services>: port number or service name For details about supported platforms, see the Command Control Interface Installation and Configuration Guide. I/O Traffic Control Synchronized I/O is issued from a virtual command device. The queueing time may occur because of the heavy I/O traffic because the virtual command device has to relay the command to the next virtual command device in the cascade configuration using the virtual command device. To improve the response in this environment, define the configuration so that asynchronous I/O is issued using the following environment variables.. $HORCM_IPSCPAIO=1 Security setting Following security can be set. Specifying security of IP address and port number By defining IP address and port number of the client PC that issues command to virtual command device to HORCM_ALLOW_INST in the configuration definition file, users who can use virtual command device can be restricted. For the details about the settings to HORCM_ALLOW_INST, please refer to "Configuration definition file". Security setting for virtual command device 3 4 CCI functions

77 By using the following environment variable, security can be set to virtual command device. $HORCM_IPCMDSEC=<value> Specify the number (from 0 to 7) to <value> depending on the contents of the security which you want, in reference with the following table. Table 3-1 Security setting for virtual command device Value specifying to <value> Security setting Command device setting User authenticatio n Device group definition Security to be set (see Notes) No security Only HORCM_DEV allowed User authentication required User authentication required Only HORCM_DEV allowed CMD security CMD security Only HORCM_DEV allowed CMD security User authentication required CMD security User authentication required Only HORCM_DEV allowed Notes: Only HORCM_DEV allowed: the operation can be performed only for paired logical volumes described in HORCM_DEV. User authentication required: only commands issued by authorized users can be executed. CMD security: only devices recognizable from the host can be operated. For details about CMD security, see Data Protection facility on page 7-5. CCI functions 3 5

78 User authentication CCI allows user authentication by using the user information managed by Storage Navigator and the SVP. User authentication is arbitrary in the Replication operation in the in-band method while the operation by user authentication is mandatory in the configuration information operation and in the out-of-band method. To enable the user authentication function, the user authentication mode of the command device accessed by CCI must be enabled. The user authentication function inputs a login command from the client (server) and, to authenticate the user ID and password sent from CCI and the same types of information maintained by the storage system, issues an authentication request to the authentication module (SVP). If the user ID and password sent from CCI are authenticated, CCI, for the once authenticated user (the user on the client starting up CCI), stores the user ID and password. This saves the necessity of inputting the user ID and password each time a command is executed. If the user logs out, the user ID and password stored by CCI are deleted. If the user ID and password are different, the command is rejected and CCI automatically performs the logout processing for it, and requires the user authentication processing (user ID and password input) again. Note: The only function that can be used if the user authentication function is disabled is the Replication function (replication command). If the user authentication function is disabled, the Provisioning function (configuration setting command) cannot be used. If specific user information or authority information is changed, delete the user ID and password maintained by the storage system from the SVP. Therefore, perform the user authentication processing on CCI again. If the communication with the SVP in the out-band method cannot be performed, the new authentication cannot be performed. Command operation authority and user authentication When CCI is used with the user authentication function enabled, commands are executed complying with the operation authority managed by Storage Navigator and the SVP. Controlling User Role CCI verifies whether or not the user executing the command on the host was already authenticated by checking the command device being in the authentication mode. After that, CCI obtains the execution authority of the command that is configured on the user role, and then compares the relevant command and the execution authority. 3 6 CCI functions

79 Checking the execution authority If the configuring commands authenticated are compared with the execution authorities of commands configured on the user role and they do not correspond, CCI rejects the command with an error code "EX_EPPERM". Normally, the user role needs to be the consistent and integrated authority among the large storage systems. In case of HORCM instances that are configured by the multiple large storage systems, the execution authorities are obtained by the serial number of the storage systems. If the user role is for the multiple storage systems and is not consistent among these storage systems, CCI makes the integrated authority by performing the logical AND of the execution authorities among the storage systems. The target commands CCI checks execution authorities on the following commands that use command devices. horctakeover, horctakeoff paircreate, pairsplit, pairresync raidvchkset Controlling user resources CCI verifies the user who executes the command has been authenticated already. After that, CCI obtains the access authority of the resource groups that are configured on the user roles, and then compares the access authority of the user and the specified resources. Checking resource authorities If the access is not permitted by comparing the access authorities of the resource groups configured on the user roles and the specified resource, CCI rejects the command with an error code "EX_EGPERM". If the resource groups are defined among the large storage systems, the specified resource is compared with the resource specified by obtaining the access authority configured to each large storage system. Target commands CCI checks resource authorities on the following commands that use command devices. raidcom commands (commands for setting configurations) horctakeover, horctakeoff, paircurchk, paircreate, pairsplit, pairresync, pairvolchk, pairevtwait, pairsyncwait, pairmon raidscan (-find verify, -find inst, -find sync except for [d]), pairdisplay, raidar, raidqry (except for -l and -r) raidvchkset, raidvchkscan (except for -v jnl), raidvchkdsp CCI functions 3 7

80 Relation between user authentication and resource groups In user authentication mode, CCI verifies the access authority of the relevant resource based on the user authentication and the role of it. Also, on the user authentication unnecessary mode and the undefined resource groups, CCI checks the access authorities shown in the following table. Table 3-2 Relations between resource groups and command devices Commands Resources Not authenticated user 2 pairxx 1 Authenticated user Not authenticated user 2 raidcom Authenticated user Undefined Permitted Permitted by resource 3 the authority of resource ID 0 Defined resource EX_EGPERM 4 Permitted by the authority of the relevant resource ID EX_EPPERM 4 EX_EGPERM 4 EX_EPPERM Notes: 1. Above-described commands except for the raidcom command 2. User who uses the mode without the command authentication 3. Undefined as the resource group 4. Command execution is rejected by the relevant error Permitted by the authority of resource ID 0 Permitted by the authority of the relevant resource ID Target resources The following objects are arbitrarily defined as the resource groups by each user. LDEV Physical port Host group RAID group External connection group Commands executed depending on operation authorities The commands and operation authority managed by Storage Navigator and SVP are listed in the following table. For information about creating the Storage Navigator user accounts, registering user accounts to user groups, and user group authorities, see the Hitachi Storage Navigator User Guide. 3 8 CCI functions

81 Table 3-3 Commands and operation authority managed by Storage Navigator and SVP Operation Operation target Authority Executable command Operation authority (Role) Setting MP blade MP blade setting authority Resource creation, deletion LDEV External volume (Universal Volume Manager) Pool Dynamic Provisioning virtual volume LDEV creation authority raidcom add ldev LDEV deletion authority External volume creation authority External path operation authority External volume disconnection authority External volume connection check and resumption authority External volume mapping release authority Pool creation and capacity change authority Pool deletion authority Dynamic Provisioning virtual volume creation authority Dynamic Provisioning virtual volume deletion authority raidcom modify ldev raidcom modify journal raidcom modify external_grp raidcom add ldev raidcom delete ldev raidcom add external_grp raidcom discover external_storage raidcom discover lun raidcom check_ext_storage path raidcom disconnect path raidcom check_ext_storage external_grp raidcom disconnect external_grp raidcom delete external_grp raidcom add dp_pool raidcom add snap_pool raidcom delete pool raidcom add ldev -pool raidcom delete ldev Storage Administrator (System Resource Management) Storage Administrator (Provisioning) Storage Administrator (Provisioning) Storage Administrator (Provisioning) Storage Administrator (Provisioning) Storage Administrator (Provisioning) Storage Administrator (Provisioning) Storage Administrator (Provisioning) Storage Administrator (Provisioning) Storage Administrator (Provisioning) Storage Administrator (Provisioning) CCI functions 3 9

82 Operation Operation target Authority Executable command Operation authority (Role) Copy-on-Write Snapshot virtual volume Port Host group LUN WWN LDEV group Local copy Remote copy Copy-on-Write Snapshot virtual volume creation authority Copy-on-Write Snapshot virtual volume deletion authority LUN security setting authority Host group creation authority Host group deletion authority LU path creation authority LU path deletion authority WWN addition authority WWN deletion authority Device group and Copy group creation authority Device group and Copy group deletion authority Pair creation authority Pair deletion authority Volume Migration pair creation authority Volume Migration pair deletion authority Pair creation authority Pair deletion authority raidcom add ldev -pool raidcom delete ldev raidcom modify port - security_switch raidcom add host_grp raidcom delete host_grp raidcom add lun raidcom delete lun raidcom add hba_wwn raidcom delete hba_wwn raidcom add device_grp raidcom add copy_grp raidcom delete device_grp raidcom delete copy_grp paircreate pairsplit -S paircreate pairsplit -S paircreate pairsplit -S Storage Administrator (Provisioning) Storage Administrator (Provisioning) Storage Administrator (System Resource Management) Storage Administrator (Provisioning) Storage Administrator (Provisioning) Storage Administrator (Provisioning) Storage Administrator (Provisioning) Storage Administrator (Provisioning) Storage Administrator (Provisioning) Storage Administrator (Provisioning) Storage Administrator (Provisioning) Storage Administrator (Provisioning) Storage Administrator (Local Copy) Storage Administrator (Local Copy) Storage Administrator (Provisioning) Storage Administrator (Provisioning) Storage Administrator (Remote Copy) Storage Administrator (Remote Copy) 3 10 CCI functions

83 Operation Operation target Authority Executable command Operation authority (Role) Attribute change External volume External path setting authority raidcom add path Storage Administrator (Provisioning) Pool Pool setting authority raidcom modify pool Storage Administrator (Provisioning) Port Port attribute setting authority raidcom modify port - port_attribute Storage Administrator (System Resource Management) Port setting authority raidcom modify port - loop_id Storage Administrator (Provisioning) raidcom modify port - topology raidcom modify port - port_speed Host group Host group setting authority raidcom add host_grp Storage Administrator (Provisioning) WWN WWN setting authority raidcom set hba_wwn raidcom reset hba_wwn Storage Administrator (Provisioning) LDEV nickname LDEV nickname setting authority raidcom modify ldev - ldev_name Storage Administrator (Provisioning) Local copy Pairsplit and resync authority pairresync Storage Administrator (Local Copy) Remote copy Environment construction authority raidcom add rcu raidcom delete rcu raidcom modify rcu Storage Administrator (Remote Copy) raidcom add rcu_path raidcom delete rcu_path raidcom add journal raidcom delete journal raidcom modify journal Pairsplit and resync authority pairresync Storage Administrator (Remote Copy) Relation between resource groups and command operations The operation for using resource groups are different by the command devices (the In-Band method) or the Out-of-Band method that are used when you start CCI. You can create resource groups for each resource. And you can share them with multiple users. When user 10 and user 20 share the port like the following figure, the relation between the command devices and resource groups that user can use is like Table 3-4 Relation between resource groups and command devices on page CCI functions 3 11

84 Figure 3-2 Relation among user, command devices, and resource groups Table 3-4 Relation between resource groups and command devices Login user Comman d device Operating range Referenc e Configuration change Out-ofband operation System administrator CM0 OK: Can operate all resource groups. OK OK OK CM10 OK: OK OK - Can operate only in the range of resource group 10. CM20 OK: OK OK - Can operate only in the range of resource group CCI functions

85 Login user Comman d device Operating range Referenc e Configuration change Out-ofband operation User 10 CM0 OK: Can operate in the range of resource group 10 and shared ports. CM10 CM20 OK: Can operate only in the range of resource group 10. NG: Nothing is displayed or the operation authority error. User 20 CM0 OK: Can operate in the range of resource group 20 and shared ports. Legend: OK: Operable NG: Inoperable CM10 CM20 NG: Nothing is displayed or the operation authority error. OK: Can operate only in the range of resource group 20. As shown in the table above, the relation among users, command devices and operations of resource groups are the following. The range that can be operated by command device 0 (CM0) or Out-of- Band is the shared range (AND) of resource groups that are allocated to each user and all resource groups. The range that can be operated by command device 10 (CM10) is the shared range (AND) of resource groups that are allocated to each user and resource group 10 that the command devices are allocated. Therefore, in the range of resource group 10 can be operated. The following shows the example of the case that the execution results of the commands change by the case of having or not having the authority of the operated resources, specifies only the objects or specifies to the parameters. When user has the authority using CL1-A, CL3-A and CL5-A ports, and CL1- A, CL2-A, CL3-A, CL4-A and CL5-A ports are implemented in the system, executes the following command. When only the objects are specified: # raidcom get port OK OK OK OK OK - Operation authority error OK OK OK Operation authority error OK OK CCI functions 3 13

86 The execution results of CL1-A, CL3-A and CL5-A are displayed. The execution results of CL2-A and CL4-A (the user does not have the authority of the resource) are not displayed (filtered). When parameters are also specified: # raidcom get port -port CL1-A The execution result of CL1-A is only displayed. # raidcom get port -port CL2-A The error is displayed because the user does not have the execution authority. The following shows the output example when -cnt that is used in get ldev is used. The following command is executed when the user has the authorities of LDEV number 10 and 12. # raidcom get ldev -ldev_id 10 -cnt 3 Execution results of LDEV number 10 and 12 are displayed. LDEV number 11 is not displayed because the user does not have the authority of the resource. Resource lock function When the configuration changes from multiple CCI, SVP, or Storage Navigator are done to the same resource, unexpected change is executed on each other and it might not be configure the expected configuration. To prevent from the changing configuration for the same resource by each of the users, the resource lock command is provided. When this command is used, the resource group can be locked for the other users that they cannot be used the specified resource group. And even if the lock is not performed, each configuration change command can be performed. However, the competition with the other application might cause an error. The commands for performing the exclusive control and exclusive control release (lock and unlock) of resource groups are as follows. raidcom lock resource -resource_name <resource group name > [-time <time(sec)>] (Locking a specified resource group) raidcom unlock resource -resource_name <resource group name > (Unlocking a specified resource group) If multiple users (IDs) operate the same resource, by confirming by the raidcom lock resource command that no other user is using the resource, the operation competition for the relevant resource can be prevented. After the configuration change is completed, release the lock status by the raidcom unlock resource command CCI functions

87 Command execution modes Overview Provisioning operations are performed using a configuration setting command. For details about the configuration setting command, see Overview of the configuration setting command on page 5-2 or Command Control Interface Command Reference. Two modes can be used for executing the configuration setting command: Line-by-line mode. This mode executes commands input from the command line one at a time. Transaction mode. Executes a script file specified by the -zt option. When executing the configuration setting command, the following checks can be done depending on the above two mode types. Syntax check This function checks if there is no syntax error in the specified command. This is executed every time at the both line-by-line mode and transaction mode. Context check This function checks the consistency of one specified line in the script and the preceding lines in the order from the top. This function is available only at the Transaction mode. For details about context checking, see Context check on page Configuration check Acquire the current configuration information to a configuration file, and then this function checks whether the resources specified in the script (LDEVs, ports, or host groups) are configured in the storage system or not. This function is available only at the transaction mode. For details about context checking, see Configuration check on page The configuration setting command also has a execution option described in the following. Precheck Specify the checkmode precheck option. It operates checking only (it does not execute processing even if no error is detected.) This can be specified at the both line-by-line mode and transaction mode. The following table shows the overview of execution modes and options of the configuration setting command. CCI functions 3 15

88 Table 3-5 Execution modes and options of the configuration setting command (lineby-line mode) Command syntax Syntax check Context check Configuration check Command execution with no error Remarks raidcom <action> Executed Not executed Not executed Executed Default raidcom <action> - Executed Not executed Not executed Not executed Check only checkmode precheck Table 3-6 Execution modes and options of the configuration setting command (transaction mode) Command syntax Syntax check Context check Configuration check Command execution with no error Remarks raidcom -zt <script file> Executed Executed Not executed Executed Default raidcom -zt <script file> -load <work file> raidcom -zt <script file> -checkmode precheck raidcom -zt <script file> -load < work file> - checkmode precheck Context check Executed Executed Executed Executed With configuration check Executed Executed Not executed Not executed Check only Executed Executed Executed Not executed With configuration check Check only Detailed description are provided in the following. Caution: Observe the following cautions: For <script file>, specify an executable file name. For <script file>, either specify a full path name or store under the c:\horcm\etc folder. For <work file>, either specify a full path name or store in the current directory. This check can be performed to ensure consistent content of the created script file. For example, it can check if the script refers to an ldev_id that is already deleted in the preceding lines. The script is executed only when no error is detected by the checking of whole script contents. The following resources can be the target of the check: LDEV Port Host group Checking the contents before executing the script helps reduce debugging after running the script CCI functions

89 How to check The script is performed by specifying it as follows. raidcom -zt <created script file name> raidcom -zt <created script file name> -load <configuration file> raidcom -zt <created script file name> -checkmode precheck raidcom -zt <created script file name> -load <configuration file> -checkmode precheck Details of check contents Details of Context check is described below. checking contents before issuing a script can reduce load for the debug operation in a way of executing script. LDEV check The check is performed from the following perspective. Note that checking for the object information that is related to the LDEV such as pool or device group, or an attribute of LDEV is not executed. Check with the additional operation It is checked to ensure no same LDEV as the already existing LDEV is added. If the same LDEV is attempted to be added, an error is detected. If it is not clear whether the LDEV to be added exists or not (if the target LDEV information does not exist in the configuration definition file), the error is not detected. Therefore, the script is executed and the LDEV is added. The command as the target of the check is shown below. raidcom add ldev {-parity_grp_id <gno-sgno> -external_grp_id <gno-sgno> -pool {<pool ID#> <pool naming> snap}} {-ldev_id <ldev#> -tse_ldev_id <ldev#>} {-capacity <size> -offset_capacity <size> -cylinder <size>} [-emulation <emulation type>][-location <lba>][-mp_blade_id <mp#>] [-clpr <clpr#>] Check with the attribute setting It is checked whether the operation is performed for the existing LDEV or not. If the operation is attempted to be performed for an LDEV that does not exist, an error is detected. If it is not clear whether the LDEV as the target of the operation exists in the configuration definition file (if the target LDEV information does not exist in the configuration definition file), the error is not detected. The commands as the target of the check are shown below. CCI functions 3 17

90 raidcom modify host_grp -port <port#> [<host group name>] - host_mode <host mode> [-host_mode_opt <host mode option> ] raidcom add hba_wwn -port <port#> [<host group name>] -hba_wwn <WWN strings> raidcom delete hba_wwn -port <port#> [<host group name>] - hba_wwn <WWN strings> raidcom set hba_wwn -port <port#>[<host group name>] -hba_wwn <WWN strings> -wwn_nickname <WWN Nickname> raidcom reset hba_wwn -port <port#>[<host group name>] -hba_wwn <WWN strings> raidcom add lun -port <port#> [<host group name>] {-ldev_id <ldev#> [-lun_id<lun#>] -grp_opt <group option> - device_grp_name <device group name> [<device name>]} raidcom delete lun -port <port#> [<host group name>] {-lun_id <lun#> -ldev_id <ldev#> -grp_opt <group option> - device_grp_name <device group name> [<device name>]} Check with the deletion operation It is checked to ensure that the operation is not intended to be performed for the LDEV that is already deleted. If it is, an error is detected. If it is not clear whether the LDEV as the target of the operation exists in the configuration definition file or not (if the target LDEV information does not exist in the configuration definition file), the error is not detected. The command as the target of the check is shown below. raidcom delete ldev {-ldev_id <ldev#> -grp_opt <group option> -device_grp_name <device group name> [<device name>]} The example of the script where the same LDEV is attempted to be added to the already created LDEV and the execution result of the Context check is shown below. Example of script raidcom add ldev -parity_grp_id ldev_id 1 -capacity 100M raidcom add ldev -parity_grp_id ldev_id 2 -capacity 100M raidcom add ldev -parity_grp_id ldev_id 3 -capacity 100M Execution result 3 18 CCI functions

91 C:\HORCM\etc>raidcom get ldev -ldev_id 1 -cnt store ldevconf_65 > ldevconf_65.txt C:\HORCM\etc>raidcom -zt 3_defined_ldev.bat -load ldevconf_65.dat - checkmode precheck C:\HORCM\etc>raidcom add ldev -parity_grp_id ldev_id 1 -capacity 100M C:\HORCM\etc>raidcom add ldev -parity_grp_id ldev_id 2 -capacity 100M C:\HORCM\etc>raidcom add ldev -parity_grp_id ldev_id 3 -capacity 100M Example of script (the text in bold indicates the part of incorrect configuration definition.) raidcom add ldev -parity_grp_id ldev_id 1 -capacity 100M raidcom add ldev -parity_grp_id ldev_id 2 -capacity 100M raidcom add ldev -parity_grp_id ldev_id 3 -capacity 100M raidcom add ldev -parity_grp_id ldev_id 1 -capacity 100M raidcom add ldev -parity_grp_id ldev_id 2 -capacity 100M raidcom add ldev -parity_grp_id ldev_id 3 -capacity 100M for /l %%i in (1,1,3) do ( raidcom add ldev -parity_grp_id ldev_id %%i -capacity 100M ) for /l %%i in (1,1,3) do ( raidcom add ldev -parity_grp_id ldev_id %%i -capacity 100M ) Execution result (the text in bold indicates the contents of the error accompanying the invalid configuration definition in the script.) CCI functions 3 19

92 C:\HORCM\etc>raidcom get ldev -ldev_id 1 -cnt store ldevconf_65 > ldevconf_65.txt C:\HORCM\etc>raidcom -zt 3_defined_ldev.bat -load ldevconf_65.dat - checkmode precheck C:\HORCM\etc>raidcom add ldev -parity_grp_id ldev_id 1 -capacity 100M C:\HORCM\etc>raidcom add ldev -parity_grp_id ldev_id 2 -capacity 100M C:\HORCM\etc>raidcom add ldev -parity_grp_id ldev_id 3 -capacity 100M C:\HORCM\etc>raidcom add ldev -parity_grp_id ldev_id 1 -capacity 100M raidcom: LDEV(1) is already existing as status is [1] on UnitID# 0. raidcom_#5 : [EX_CTXCHK] Context Check error C:\HORCM\etc>raidcom add ldev -parity_grp_id ldev_id 2 -capacity 100M raidcom: LDEV(2) is already existing as status is [1] on UnitID# 0. raidcom_#6 : [EX_CTXCHK] Context Check error C:\HORCM\etc>raidcom add ldev -parity_grp_id ldev_id 3 -capacity 100M raidcom: LDEV(3) is already existing as status is [1] on UnitID# 0. raidcom_#7 : [EX_CTXCHK] Context Check error The number in raidcom # of raidcom_#7: [EX_CTXCHK] Context Check error is the number of times of performing the raidcom command by using <work file>. The number of times is incremented each time the raidcom command is executed. Port check The check is performed from the following perspective. Note that checking for object information related to the port, such as external volume group or RCU, or an attribute of port, is not executed. Checking for attribute setting It is checked whether the operation is performed for the existing port. If the port does not exist, an error is detected. If it is not clear whether the port as the target of the operation exists in the configuration definition file or not (if the target port information does not exist in the configuration definition file), the error is not detected. The commands as the target of the check are shown below. raidcom modify port -port <port#>{[-port_speed <value>] [-loop_id <value>][-topology <topology>] [-security_switch < y n >] - port_attribute <port attribute>} raidcom add external_grp -path_grp <path group#> -external_grp_id <gnosgno> -port <port#> -external_wwn <wwn strings> -lun_id <lun#> [-emulation <emulation type>] [-clpr <clpr#>] 3 20 CCI functions

93 raidcom add path -path_grp <path group#> -port <port#> - external_wwn <wwn strings> raidcom delete path -path_grp <path group#> -port <port#> - external_wwn <wwn strings> raidcom check_ext_storage path -path_grp <path group#> -port <port#> -external_wwn <wwn strings> raidcom disconnect path -path_grp <path group#> -port <port#> - external_wwn <wwn strings> raidcom add rcu {-rcu <serial#> <mcu#> <rcu#> <id> -ssid <ssid> -cu_free <serial#> <id> <pid>} -mcu_port <port#> -rcu_port <port#> For example, if a path is attempted to be added to a port that does not exist, an error is detected. An example of the script where the error is detected and the execution result of the actual Context check are shown below. Example of script (the text in bold indicates the part of incorrect configuration definition.) raidcom add path -path_grp 1 -port CL1-C -external_wwn 50060e80,06fc4180 raidcom add path -path_grp 1 -port CL1-D -external_wwn 50060e80,06fc4190 raidcom add path -path_grp 1 -port CL1-E -external_wwn 50060e80,06fc41a0 Execution result (the text in bold indicates the contents of the error accompanying the invalid configuration definition in the script.) CCI functions 3 21

94 C:\HORCM\etc>raidcom get port -store portcnf_27.dat PORT TYPE ATTR SPD LPID FAB CONN SSW SL Serial# WWN CL1-A FIBRE TAR AUT EF N FCAL N fc1b000000fc1b CL1-B FIBRE TAR AUT EF N FCAL N e8006fc1b01 CL2-A FIBRE TAR AUT EF N FCAL N e8006fc1b10 CL2-B FIBRE TAR AUT EF N FCAL N e8006fc1b11 CL3-A FIBRE TAR AUT E8 N FCAL N e8006fc1b20 CL3-B FIBRE TAR AUT E0 N FCAL N e8006fc1b21 CL4-A FIBRE TAR AUT D6 N FCAL N e8006fc1b30 CL4-B FIBRE TAR AUT D2 N FCAL N e8006fc1b31 CL5-A FIBRE TAR AUT E4 N FCAL N e8006fc1b40 CL5-B FIBRE TAR AUT DC N FCAL N e8006fc1b41 CL6-A FIBRE TAR AUT D5 N FCAL N e8006fc1b50 CL6-B FIBRE TAR AUT D1 N FCAL N e8006fc1b51 CL7-A FIBRE ELUN AUT E2 N FCAL N e8006fc1b60 CL7-B FIBRE ELUN AUT DA N FCAL N e8006fc1b61 CL8-A FIBRE TAR AUT D4 N FCAL N e8006fc1b70 CL8-B FIBRE TAR AUT CE N FCAL N e8006fc1b71 C:\HORCM\etc>raidcom -zt 4_no_port.bat -load portcnf_27.dat -checkmode precheck C:\HORCM\etc>raidcom add path -path_grp 1 -port CL1-C -external_wwn 50060e80,06fc4180 raidcom: PORT(2) does not exist as status is [2] on UnitID# 0. raidcom_#2 : [EX_CTXCHK] Context Check error C:\HORCM\etc>raidcom add path -path_grp 1 -port CL1-D -external_wwn 50060e80,06fc4190 raidcom: PORT(3) does not exist as status is [2] on UnitID# 0. raidcom_#3 : [EX_CTXCHK] Context Check error C:\HORCM\etc>raidcom add path -path_grp 1 -port CL1-E -external_wwn 50060e80,06fc41a0 raidcom: PORT(4) does not exist as status is [2] on UnitID# 0. raidcom_#4 : [EX_CTXCHK] Context Check error Host group check The check is performed from the following perspective. Note that checking for an attribute of host group, or for a name of host group is not executed. Check with the attribute setting Checks whether the operation is performed for an existing host group. If the host group does not exist, an error is detected. If it is not clear whether the target port or host group exists (if the target port or host group information does not exist in the configuration definition file), the error is not detected. The commands as the target of the check are shown below CCI functions

95 raidcom modify host_grp -port <port#> [<host group name>] - host_mode <host mode> [-host_mode_opt <host mode option> ] raidcom add hba_wwn -port <port#> [<host group name>] -hba_wwn <WWN strings> raidcom delete hba_wwn -port <port#> [<host group name>] - hba_wwn <WWN strings> raidcom set hba_wwn -port <port#>[<host group name>] -hba_wwn <WWN strings> -wwn_nickname <WWN Nickname> raidcom reset hba_wwn -port <port#>[<host group name>] -hba_wwn <WWN strings> raidcom add lun -port <port#> [<host group name>] {-ldev_id <ldev#> [-lun_id<lun#>] -grp_opt <group option> - device_grp_name <device group name> [<device name>]} raidcom delete lun -port <port#> [<host group name>] {-lun_id <lun#> -ldev_id <ldev#> -grp_opt <group option> - device_grp_name <device group name> [<device name>]} Check with deletion operation It is checked to ensure that the operation is not intended to be performed for the host group that is already deleted. If the host group is already deleted, an error is detected. If it is not clear whether the target port or host group exists or not (if the target port or host group information does not exist in the configuration definition file), the error is not detected. The command as the target of the check is shown below. raidcom delete host_grp -port <port> [<host group name>] For example, if the host group that does not exist is attempted to be deleted, an error is detected. An example of the script where the error is detected and the execution result of the actual context check are shown below. Example of script (the text in bold indicates the part of incorrect configuration definition.) raidcom delete host_grp -port CL1-A-0 raidcom delete host_grp -port CL1-A-1 raidcom delete host_grp -port CL1-A-2 Execution result (the text in bold indicates the contents of the error accompanying the invalid configuration definition in the script.) CCI functions 3 23

96 Configuration check C:\HORCM\etc>raidcom get host_grp -port CL1-A -store hostgrpcnf_27_cl1-a.dat PORT GID GROUP_NAME Serial# HMD HMO_BITs CL1-A 0 1A-G LINUX/IRIX C:\HORCM\etc>raidcom -zt 6_no_hstgrp.bat -load hostgrpcnf_27_cl1-a.dat -checkmode precheck C:\HORCM\etc>raidcom delete host_grp -port CL1-A-0 C:\HORCM\etc>raidcom delete host_grp -port CL1-A-1 raidcom: PORT-HGRP(0-1) does not exist as status is [2] on UnitID# 0. raidcom_#3: [EX_CTXCHK] Context Check error C:\HORCM\etc>raidcom delete host_grp -port CL1-A-2 raidcom: PORT-HGRP(0-2) does not exist as status is [2] on UnitID# 0. raidcom_#4 : [EX_CTXCHK] Context Check error The contents of a script file can be checked whether the operation is performed for the existing resource or not. Before performing the configuration check, execute the following command, acquire the current configuration information, and store it in the work file specified by the -store option. Check the operation for LDEV raidcom get ldev {-ldev_id <ldev#> [-cnt <count>] -grp_opt option> -device_grp_name <device group name> [<device name>]} <work file> <group -store Check the operation for Port raidcom get port -port -store <work file> Check the operation for Host group raidcom get host_grp -port <port> -store <work file> After acquiring the configuration information, execute the script by specifying the configuration file. raidcom -zt <created script file name> -load <work file> Resource location and parameter MP blade location and parameter To specify MP blade IDs by the raidcom add ldev command, specify the following IDs CCI functions

97 Table 3-7 MP blade names and parameters for VSP G1000 MP blade name MP blade number MP blade ID MPB-1MA 0 0 MPB-1MB 1 1 MPB-1PE 2 2 MPB-1PF 3 3 MPB-2MA 4 4 MPB-2MB 5 5 MPB-2PE 6 6 MPB-2PF 7 7 MPB-1MC 8 8 MPB-1MD 9 9 MPB-1PL MPB-1PM MPB-2MC MPB-2MD MPB-2PL MPB-2PM Table 3-8 MP blade names and parameters for VSP MP blade name MP blade number MP blade ID MPB-1MA 0 0 MPB-1MB 1 1 MPB-2MC 2 2 MPB-2MD 3 3 MPB-1ME 4 4 MPB-1MF 5 5 MPB-2MG 6 6 MPB-2MH 7 7 Table 3-9 MP unit names and parameters for HUS VM MP unit name MP blade number MP blade ID MPU MPU MPU MPU LDEV grouping function The LDEV grouping function enables you to create a group of multiple LDEVs (device group function and copy group function). CCI functions 3 25

98 Overview CCI can be used to create a group of multiple LDEVs by defining copy groups, which are a group of copy pairs. This is accomplished in both the primary and secondary configuration definition files by defining the group names of the combined LDEVs (dev_name of HORCM_DEV or HORCM_LDEV). To change copy group information, modify the primary and secondary configuration definition files. For example, to change the LDEV configuration of copy group dba (see following figure), change the LDEV information in configuration definition files A and B CCI functions

99 Figure 3-3 LDEV grouping for USP V/VM and earlier For Virtual Storage Platform and later, CCI can be used to create a group of multiple LDEVs by defining device groups. This is accomplished by defining device groups in either the primary or secondary configuration definition file, but not both. By defining a device group, LDEV information can be changed or defined in one operation. It is not required to modify LDEV information in both configuration definition files. For example, referencing LDEVs or creating pools can be executed at the same time, because all LDEVs in the device group are subjected to the operation. CCI functions 3 27

100 Figure 3-4 LDEV grouping for VSP and later (device group and copy group) However, for executing replication function commands in CCI, two device groups must be combined and defined as a copy group CCI functions

101 When defining a device group or copy group by a command, the command can be issued from multiple CCI instances because the group information is defined in the storage system. Device group definition methods To define a device group or copy group in the CCI that supports Virtual Storage Platform or later, use one or both of following methods. Execute a command Create a device group with the raidcom add device_grp command, and execute the raidcom add copy_grp command specifying the name of the device group to define a copy group. When the command is executed, a description corresponding to HORCM_LDEV of CCI is defined in the storage system. Then, define HORCM LDEVG in the configuration file to incorporate it into the CCI instance. This can be executed at CCI that supports Virtual Storage Platform or later. Define a configuration definition file Define HORCM_LDEV or HORCM_DEV of the configuration definition files of the primary and secondary volumes. For definition details, see Configuration definition file on page A device name is a name given to an LDEV in each device group.this is equivalent to the dev_name definition of HORCM_DEV. A device name is not required, but it is convenient to use to specify device group or device name instead of LDEV number. However, to create a pool or a journal, specifying LDEV number is required. The LDEVs that have the same device name are recognized as a pair in the primary and secondary device group. Therefore, make match the device name for the LDEV to be a pair. Also, the number of LDEVs in the device group must be the same at the primary and secondary sides. Pairs are operated in the ascending sequence of the LDEV numbers. If there is no corresponding device name of LDEV in the device group to be paired, an error might be occurred on the pair operation. Read operations and command device settings When grouping LDEVs, if HORCM_LDEVG on the primary side and secondary side is not defined, the read operation of CCI is different depending on the command device settings. The following table shows the details. CCI functions 3 29

102 Table 3-10 Reading of command device setting and group information HORCM_LDEVG Securit y Command device setting User authentication Group information acquisition Reading of device group or copy group information Security to be set Not defined OFF OFF OFF Do not read No security ON Do not read Only HORCM_DEV allowed OFF ON OFF Read 1 User authentication required ON Do not read User authentication required Only HORCM_DEV allowed ON OFF OFF Read 1 CMD security ON Do not read CMD security Only HORCM_DEV allowed ON ON OFF Read 1 CMD security User authentication required ON Do not read CMD security User authentication required Only HORCM_DEV allowed Defined Read 2 - Notes: 1. Read the entire group information in the storage system. 2. Read the information of device group and copy group from the contents of the configuration definition file regardless of the setting of the command device. Define device group A device group is created by specifying a device name and a device group name. Once a device group is created, the device group name, the LDEV number, and the information if there is copy group definition or not are stored in the storage system as configuration information. The maximum number of device groups is 1,024 in one storage system. The maximum 65,279 LDEVs can be placed under the device group. And one LDEV can be placed in multiple device groups. Notes when specifying a device name Multiple device names can be defined in one LDEV (Max: 1,024 names). The length of a device name must be up to 32 characters CCI functions

103 In the device group that does not become an element of copy a group, the same device name can be used in the same device group. In the device group that becomes an element of a copy group, a device group name must be unique in the device group. It is because a pair is created between LDEVs that have same device names in respective primary and secondary volumes at the group operation of a replication series command. Notes when specifying a device group name The length of a device group name must be up to 32 characters. A device group name must be unique within the storage system. The device group name cannot be duplicated in one storage system. When a device group name is specified by the raidcom command option and an LDEV to operate is specified by the device name, all devices that have the same name with the beginning of the specified name will be operated. The contents of the following operations that can be executed for a device group are expressed hereafter with its use cases. 1. Device group creation 2. LDEV addition to device group 3. LDEV deletion from device group 4. Device group deletion Note: The following symbols are used in the use cases described hereafter. Device group creation Creating a device group by specifying a subject of multiple LDEV IDs and device group names of the device groups to be created. Use cases. The following examples show use cases for creating a device group. Creating a device group configured of simplex volumes with different device names. Creating a device group configured of a simplex volume and a paired volume with different device names. CCI functions 3 31

104 Creating a device group configured of simplex volumes with same device names. LDEV addition to device group Adding an LDEV to the device group by specifying a created device group name and the LDEV ID of the LDEV to be added. Use Cases The following shows use cases that can be added an LDEV to a device group. Adding an LDEV (simplex volume) with a different device name to a device group. Adding an LDEV (paired volume) with a different device name to a device group. Adding an LDEV to a device group already including the same device name. The device name can be duplicated in the case of not creating the copy group by specifying a device group CCI functions

105 LDEV deletion from device group Deleting an LDEV from the device group by specifying a created device group name and an LDEV ID of the LDEV to be deleted. LDEV can be deleted from the device group associating a copy group. The pair status does not change even if the LDEV is deleted from the device group. Use Cases The following shows use cases that can be deleted an LDEV from a device group. Deleting an LDEV (simplex volume) not associated with a copy group from a device group. Deleting an LDEV (paired volume) not associated with a copy group from a device group. Deleting an LDEV (simplex volume) associated with a copy group from a device group. Deleting an LDEV (paired volume) associated with a copy group from a device group. CCI functions 3 33

106 Device group deletion Deleting an LDEV that configuring a device group by specifying a created device group name and an LDEV ID of the LDEV to be deleted. If all the LDEVs configuring the device group are deleted from the device, the relevant device group is deleted. And, even if a device group is deleted, the pair status of the pair in the device group does not change. Use Cases The following shows use cases that can be deleted an LDEV from a device group. Deleting a device group configured of simplex volumes and not associated with a copy group. Deleting a device group configured of a simplex volume and a paired volume and not associated with a copy group. Deleting a device group configured of simplex volumes and associated with a copy group. Deleting a device group configured of paired volumes and associated with a copy group CCI functions

107 Copy group function Defining a copy group by specifying two device groups: one device group from primary side and one device group from secondary side, whether they are inside or outside the storage system. A copy group cannot be defined by specifying more than one device group from just one side of primary or secondary. When a copy group is created, which device group is primary and which is secondary cannot be specified. Therefore, it is specified at the time of actual pair creation. As configuration information, a copy group name, a device group name (primary and secondary), and an MU# are maintained in the storage system. The notes when operating copy groups are shown below. When creating a copy group In case of creating a copy group by executing a command, a copy group cannot be created through direct specification of multiple LDEVs. Create a copy group by specifying a device group. In one device group associated as a copy group, the same device name cannot be defined. Copy groups with the same name cannot be defined within the same storage system. One device group cannot be defined to multiple copy groups. The maximum number of copy groups per storage system is 16,384. At the time of consistency group creation (pair creation) and consistency group deletion (pair deletion), the collaboration with the group operations (device group creation/deletion, copy group creation/ deletion) is not performed. When deleting a copy group If a copy group is deleted, the association of two device groups is deleted. However, the actual pair status, the consistency group ID and others are not changed (not affected). Even if the pair status in the copy group is not single and the copy group is deleted, the copy group deletion processing is performed. If an LDEV is deleted from a device group associated as a copy group, the relevant LDEVs are deleted from all the associated copy groups. A copy group defines the relationship of device groups. Therefore, it is not possible to specify an LDEV and remove it from the copy group. Regardless of the pair status (copy status), it is possible to exclude LDEVs from device groups associated as a copy group. The contents of the following operations that can be executed for a copy group are expressed hereafter with its use cases. 1. Copy group creation 2. LDEV addition to copy group CCI functions 3 35

108 3. LDEV deletion from copy group 4. Copy group deletion 5. Pair operation by specifying a copy group Note: The following symbols are used in the use cases described hereafter. Copy group creation Specifying two device groups and creating a copy group. The same device name must not be defined for any LDEVs in a specified device group. A copy group can be created whether the LDEV in the device group is paired status or not. Use cases The following shows use cases that can be created a copy group. Creating a copy group in cases where two device groups are configured of simplex volumes and the device names and the LDEV numbers in the respective device groups are the same. In the following example, when a copy group is created, the LDEVs within the device names of A to A and B to B become a subject of pair operation. Creating a copy group in cases where two device groups are configured of paired volumes and the device names and the LDEV numbers in the respective device groups are the same. In the following example, although pairs have been created on the device names of A to A and B to B, a copy group can be created CCI functions

109 LDEV addition to a copy group Adding an LDEV to a device group by specifying a device group name forming a copy group. It is not possible to add LDEVs directly to the copy group. With the same device name, the operation for the device group associated with a copy group cannot be performed. Use cases The following shows use cases that can be added an LDEV to the device group associating a copy group. Adding an LDEV with a different device name (simplex volume) to a device group forming a copy group. Adding an LDEV with a different device name (paired volume) to a device group forming a copy group. LDEV deletion from copy group Deleting an LDEV from a device group forming a copy group. It can be deleted both the simplex volume or paired volume LDEVs. It is not possible to delete LDEVs directly from the copy group. Use cases The following shows use cases that can be deleted LDEVs from the device group forming a copy group. Deleting an LDEV (simplex volume) from a device group forming a copy group. CCI functions 3 37

110 Deleting an LDEV (paired volume) from a device group forming a copy group. Copy group deletion Deleting a copy group by specifying a defined copy group. Use cases A copy group can be deleted even if it is configured of simplex volumes or paired volumes. The following shows use cases that can be deleted a copy group. Deleting a copy group configured of simplex volumes. Deleting a copy group configured of paired volumes CCI functions

111 Pair operation by specifying a copy group Specifying a copy group and creating a pair. Pairs are created for which the same device names of LDEV defined in respective device groups of the LDEVs. Therefore, it is required to give a same device name for the item to be operated as a pair. If a consistency group attribute is valid and no consistency group ID is specified, automatically assign a consistency group ID (1 copy group=1 consistency group). If the automatic consistency group assignment is specified and the other pairs in a copy group already have consistency group IDs, assign the same consistency group ID. If there is no target LDEV to be a pair in the copy group, the process is terminated by detecting an error. Use cases As an example of pair operation, the following shows use cases that can be created a pair by specifying a copy group. Creating a pair in cases where the device names and the numbers of LDEVs in two device groups in a copy group configured of simplex volumes are the same. In the following example, pairs are created with LDEVs that have the same device name, A to A and B to B. Creating a pair in cases where the device names and the numbers of LDEVs in two device groups in a copy group configured of simplex volumes and paired volumes are the same. In the following example, a pair is created with LDEVs for the device name A. And no operation is performed for the volumes of device name B that are already formed into copy pairs. CCI functions 3 39

112 Creating a pair in cases where different device names exist in two device groups in a copy group configured of simplex volumes. In the following example, a pair for device name A can be created, but not for device name B and C because they have different names. Creating a pair in cases where the device names in two device groups in a copy group configured of simplex volumes and paired volumes are different. In the following example, a pair for device name A to A can be created. For the device name B and C, although it does not change the paired status, but an error occurs because they have different device names. Creating a pair in cases where the numbers of LDEVs in two device groups in a copy group configured of simplex volumes are different. In the following example, pairs are created for the device name A to A and B to B CCI functions

113 Pair operations with mainframe volumes You can create a pair with mainframe LDEVs using CCI. However, some of the replication functions are not available in CCI. For more detailed information, see the user manual for the replication function: Hitachi TrueCopy for Mainframe User Guide, Hitachi Universal Replicator for Mainframe User Guide, or Hitachi ShadowImage for Mainframe User Guide. Using "dummy" LUs for mainframe LDEVs Pseudo-LUs called "dummy" LUs are used to access mainframe LDEVs in CCI. The dummy LUs are unconditionally defined for all mainframe device emulation types. Since the dummy LUs are used only by CCI, other user interfaces such as Storage Navigator and host servers do not display the dummy LUs. Two dummy LUs are assigned to each mainframe LDEV. The port IDs of the mainframe PCBs are assigned as the port IDs for the dummy LUs. Host modes cannot be defined for dummy LUs. To determine the port number for dummy LUs, use the following formula: Port#:Installed Port#(*1) (LDEV# / 0x4000)x32 Installed Port#(*1) (LDEV# / 0x4000)x32+1 *1: The lowest port number of the installed mainframe ports. TID: LU-M: (LDEV# & 03xFCO)/64 (LDEV# &0x3F) To perform pair operations on mainframe volumes just like on open-system volumes, include the mainframe LDEV# in the HORCM_LDEV section of the configuration definition file. If you have mainframe pairs that already exist, you can verify their MU # using the raidscan command. Pair status and access permission for mainframe LDEVs The pair status of mainframe LDEVs is displayed in the same way as for open-system LDEVs. However, access permissions to mainframe P-VOLs and S-VOLs are different from those of open volumes. The following tables show the pair status and access permissions for mainframe LDEVs. For more information about displayed pair status of open LDEVs, see TrueCopy/ ShadowImage/Universal Replicator pair status on page CCI functions 3 41

114 Table 3-11 Pair status and access permission for TrueCopy/TrueCopy for Mainframe Pair status in Storage Navigator Pair status in CCI Open Mainframe Open Mainframe Access to mainframe P-VOL Access to mainframe S-VOL Notes SMPL Simplex SMPL SMPL Read/write enabled COPY Pending COPY COPY Read/write enabled PAIR Duplex PAIR PAIR Read/write enabled PSUS (pair suspended split) PSUE (pair suspended error) Suspended PSUS PSUS Read/write enabled Suspended PSUE PSUE Read/write enabled Read/write enabled Reject Reject Reject 1 Reject 1 not in pair copying Table 3-12 Pair status and access permission for Universal Replicator/Universal Replicator for Mainframe pair suspend suspend by failure PDUB - PDUB inconsistency in LUSE status SSWS SSWS SSWS SSWS - Read/write enabled Notes: 1. When the system option mode 20 is on, this is a read only volume. 2. PDUB (inconsistency in LUSE status) does not exist in the mainframe system. HAM only/ horctakeover only Pair status in Storage Navigator Pair status in CCI Open Mainframe Open Mainframe Access to mainframe P-VOL Access to mainframe S- VOL Notes SMPL Simplex SMPL SMPL Read/write enabled COPY Pending COPY COPY Read/write enabled PAIR Duplex PAIR PAIR Read/write enabled PSUS (pair suspended split) PSUE (pair suspended error) Suspend PSUS PSUS Read/write enabled Suspend PSUE PSUE Read/write enabled Suspending Suspending PAIR PAIR Read/write enabled Deleting Deleting PAIR / COPY PAIR / COPY Read/write enabled Read/write enabled Reject Reject Reject* Reject* Reject Reject not in pair copying pair suspend suspend pair pair/copying 3 42 CCI functions

115 Pair status in Storage Navigator Pair status in CCI Open Mainframe Open Mainframe Access to mainframe P-VOL Access to mainframe S- VOL Notes HOLD Hold PSUS PSUS Read/write enabled HOLDING Holding PSUS PSUS Read/write enabled Reject* PSUS (HLDE) Hlde PSUE PSUE Read/write enabled Reject PFUL Suspend PFUL PFUL Read/write Reject enabled PFUS Suspend PFUS PFUS Read/write Reject enabled SSWS Suspend SSWS SSWS - Read/write enabled *When system option mode 20 is on, this is a read-only volume. suspend - suspend suspend suspend suspend suspend Table 3-13 Pair status and access permission for ShadowImage/ShadowImage for Mainframe Pair status in Storage Navigator Pair status in CCI Open Mainframe Open Mainframe Access to mainframe P-VOL Access to mainframe S-VOL Notes SMPL Simplex SMPL SMPL Read/write enabled COPY(PD) Pending COPY COPY Read/write enabled PAIR Duplex PAIR PAIR Read/write enabled COPY (SP) SP-Pend COPY COPY Read/write enabled PSUS (SP) V-split PSUS PSUS Read/write enabled PSUS (pair suspended split) PSUE (pair suspended error) Split PSUS PSUS Read/write enabled Suspend PSUE PSUE Read/write enabled Read/write enabled Reject Reject Reject Read/write enabled Read/write enabled Reject Operational differences for multiplatform volumes simplex copying The following table shows the operational differences for TrueCopy, Universal Replicator, and ShadowImage multiplatform volumes. pair suspend (in COPY(SP) COPY- COPY) suspend (in Quick Split PSUS-COPY) suspend suspend by failure COPY (RS) Resync COPY COPY Read/write Reject resynchronizing enabled COPY (RS-R) Resync-R RCPY RCPY Reject Reject restoring CCI functions 3 43

116 Table 3-14 Operational differences for multiplatform volumes LU path definition LU path information reported to CCI ShadowImage operations TrueCopy operations Universal Replicator operations LU path is defined. Actual LU path information is reported. ShadowImage for Mainframe operations Commands are rejected. Commands are rejected. LU path is not defined. Dummy LU number is reported. ShadowImage for Mainframe operations Commands are rejected. Commands are rejected. Operational differences for replication commands The following table shows the differences between open volumes and mainframe volumes in replication commands. For details on the differences, see the manual for each program product. Table 3-15 Differences in replication commands Command Option Description Operation in open systems Operation in mainframe systems Notes paircreate* -c <size> Specifies track size when copying. -m grp [CTGID] If CTGID is not specified, CTGID is automatically assigned and a pair is registered to the CT group.if CTGID is specified, a pair is registered to the CTGID in use. TrueCopy: You can specify 1 to 15 tracks. You can specify this option. TrueCopy for Mainframe: 3 or 15 tracks When you specify the number 1 to 3, the copy speed is 3 tracks. When you specify the number 4 to 15, the copy speed is 15 tracks. You can specify this option. This option is not supported in Universal Replicator or Universal Replicator for Mainframe. There is no difference between ShadowImage and ShadowImage for Mainframe. ShadowImage pairs and ShadowImage for Mainframe pairs cannot be registered to the same CTG ID.If both ShadowImage pairs and ShadowImage for Mainframe pairs are registered to one group, the command ends abnormally CCI functions

117 Command Option Description Operation in open systems Operation in mainframe systems Notes pairsplit -r -rw Specifies access mode to S-VOL after splitting a pair. -r: Read only -rw: Read/ write enabled The volume cannot be read regardless of specified options. Global virtualization function (VSP G1000 only) This option is only for TrueCopy, TrueCopy for Mainframe, Universal Replicator, and Universal Replicator for Mainframe. You cannot specify this option in ShadowImage or ShadowImage for Mainframe. *If the capacity of the S-VOL is larger than that of the P-VOL, you cannot create a pair with CCI. To create a TrueCopy for Mainframe pair with volumes that differ in capacity, use Business Continuity Manager or Storage Navigator. Notes: A mainframe primary volume may also be called a source volume or a main volume. A mainframe secondary volume may also be called a target volume or a remote volume. The global virtualization function enables you to minimize rewrites of configuration definition files (horcm*.conf) when you operate volumes migrated from other storage system models to the VSP G1000. For details on the global virtualization function, see the Provisioning Guide for Open Systems. System configuration example with the global virtualization function This topic shows a system configuration with the global virtualization function. In this configuration, a virtual storage machine is created in two VSP G1000 storage systems respectively. Volumes in the virtual storage machine are given virtual LDEV IDs. Primary site Storage system: VSP G1000 (S/N: 67000) Virtual storage machine: VSP (S/N: 65000) LDEV ID of VSP G1000: 10:00 and 10:01 Virtual LDEV ID: 01:00 and 01:01 Secondary site Storage system: VSP G1000 (S/N: 68000) Virtual storage machine: VSP (S/N: 66000) LDEV ID of VSP G1000: 10:00 and 10:01 Virtual LDEV ID: 02:00 and 02:01 CCI functions 3 45

118 Using CCI in a system configuration with the global virtualization function To use CCI with the system configuration using the global virtualization function, the following two methods can be used. Specifying a virtual storage machine to HORCM_VCMD in configuration definition files Specifying a virtual storage machine to command options (that is, -s <seq#> or -u <unit id>) If you specify the virtual storage machine to HORCM_VCMD of the configuration file, the shell scripts can be used continuously, because you do not need to modify their scripts. However, if you define HORCM_VCMD, you cannot operate the virtual storage machine whose the serial number is not specified by HORC_VCMD. If you specify the virtual storage machine to the command options (that is, -s <seq#> or -u <unit id>) instead of specifying with HORCM_VCMD, you can also operate the virtual storage machine of the serial number not specifying to HORCM_VCMD. After you change the virtual storage machine configuration with the raidcom add resource command or the raidcom delete resource command, restart HORCM CCI functions

119 Specifying a virtual storage machine by HORCM_VCMD Configuration definition file settings when specifying a virtual storage machine by HORCM_VCMD This topic shows configuration definition file settings with the global virtualization function when specifying a virtual storage machine by HORCM_VCMD. For details on other parameters, see Configuration definition file on page HORCM_CMD Specify a volume belonging to meta_resource in VSP G1000 as the command device. CCI obtains the virtual storage machine information defined in VSP G1000 via the specified command device, and configure the virtual storage machine components. When you specify a volume in the virtual storage machine as the command device in the system configuration with the global virtualization function, you cannot start CCI. HORCM_VCMD In the beginning of HORCM_VCMD, specify a serial number of the virtual storage machine to be operated by this instance. If you specify the serial number of the virtual storage machine to HORCM_VCMD, even if you do not specify the command option (that is, -s <seq#> or -u <unit ID>), the virtual storage machine of the serial number defined with the beginning of HORCM_VCMD is operated. If you define HORCM_VCMD, you cannot operate the virtual storage machines whose serial numbers are not specified by HORCM_VCMD. When you specify a virtual storage machine that is not specified with HORCM_VCMD by command options (that is, -s <seq#> or -u <unit id>), error occurs. To operate more than one virtual storage machine from a instance, specify serial numbers of the virtual storage machines with HORCM_VCMD. To operate the virtual storage machine specified in the second or later of HORCM_VCMD, use the command options (that is, -s <seq#> or -u <unit id>). HORCM_LDEV Specify volumes to be copied. Serial numbers of the virtual storage machine and virtual LDEV IDs must be specified. You cannot specify the volumes with HORCM_DEV in the system configuration with the global virtualization function. Specify the volumes with HORCM_LDEV. HORCM_INST Specify an IP address and a service name of the remote host as it is for not using the global virtualization function. Example of the configuration definition files when specifying a virtual storage machine by HORCM_VCMD Example of the configuration definition files (HORCM0) The underlined parts indicate the information that needs to modify from the file of the old model. CCI functions 3 47

120 #/******** HORCM0 on PHOST *****/ HORCM_MON #ip_address service poll(10ms) timeout(10ms) NONE horcm #/********** For HORCM_CMD ****************/ HORCM_CMD #dev_name \\.\CMD :/dev/rdsk HORCM_VCMD # redefine Virtual DKC Serial# as unitids HORCM_LDEV Ora dev :00 h1 Ora dev :01 h1 #/********** For HORCM_INST ****************/ HORCM_INST #dev_group ip_address service Ora RHOST horcm1 Example of the configuration definition files (HORCM1) The underlined parts indicate the information that needs to modify from the file of the old model. #/******** HORCM1 on RHOST *****/ HORCM_MON #ip_address service poll(10ms) timeout(10ms) NONE horcm #/********** For HORCM_CMD ****************/ HORCM_CMD #dev_name \\.\CMD :/dev/rdsk HORCM_VCMD # redefine Virtual DKC Serial# as unitids HORCM_LDEV Ora dev :00 h1 Ora dev :01 h1 #/********** For HORCM_INST ****************/ HORCM_INST #dev_group ip_address service Ora PHOST horcm0 The raidqry command display example # raidqry -l No Group Hostname HORCM_ver Uid Serial# Micro_ver Cache(MB) raidmanager / / Specifying a virtual storage machine by command options Configuration definition file settings when specifying a virtual storage machine by command options This topic shows configuration definition file settings with the global virtualization function when specifying a virtual storage machine by command options. For details on other parameters, see Configuration definition file on page HORCM_CMD 3 48 CCI functions

121 Specify a volume belonging to meta_resource in VSP G1000 as the command device. CCI obtains the virtual storage machine information defined in VSP G1000 via the specified command device, and configure the virtual storage machine components. When you specify a volume in the virtual storage machine as the command device in the system configuration with the global virtualization function, you cannot start CCI. HORCM_LDEV Specify volumes to be copied. Serial numbers of the virtual storage machine and virtual LDEV IDs must be specified. You cannot specify the volumes with HORCM_DEV in the system configuration with the global virtualization function. Specify the volumes with HORCM_LDEV. HORCM_INST Specify an IP address and a service name of the remote host as it is for not using the global virtualization function. Example of the configuration definition files when specifying a virtual storage machine by command options Example of the configuration definition files (HORCM0) The underlined parts indicate the information that needs to modify from the file of the old model. #/******** HORCM0 on PHOST *****/ HORCM_MON #ip_address service poll(10ms) timeout(10ms) NONE horcm #/********** For HORCM_CMD ****************/ HORCM_CMD #dev_name \\.\CMD :/dev/rdsk HORCM_LDEV Ora dev :00 h1 Ora dev :01 h1 #/********** For HORCM_INST ****************/ HORCM_INST #dev_group ip_address service Ora RHOST horcm1 Example of the configuration definition files (HORCM1) The underlined parts indicate the information that needs to modify from the file of the old model. #/******** HORCM1 on RHOST *****/ HORCM_MON #ip_address service poll(10ms) timeout(10ms) NONE horcm #/********** For HORCM_CMD ****************/ HORCM_CMD #dev_name \\.\CMD :/dev/rdsk HORCM_LDEV Ora dev :00 h1 Ora dev :01 h1 CCI functions 3 49

122 #/********** For HORCM_INST ****************/ HORCM_INST #dev_group ip_address service Ora PHOST horcm0 Commands to the virtual storage machine When HORCM starts, CCI obtains the virtual storage machine information from multiple storage systems, and configure each virtual storage machine component. CCI regards commands as the command to the virtual storage machine by the descriptions of the configuration definition file or the command options (that is, -s <seq#> or -u <unit id>), and use their information. The following table shows how to issue the command to the virtual storage machine for each command. Commands How to issue the command to the virtual storage machine Remarks paircreate pairsplit pairresync pairevtwait pairvolchk pairdisplay paircurchk horctakeover raidvchkset raidvchkdsp pairsyncwait Describe the virtual storage machine information in HORCM_LDEV in the configuration definition file. Describe the virtual storage machine information in HORCM_LDEV in the configuration definition file. Describe the virtual storage machine information in HORCM_LDEV in the configuration definition file. Describe the virtual storage machine information in HORCM_LDEV in the configuration definition file. Describe the virtual storage machine information in HORCM_LDEV in the configuration definition file. Describe the virtual storage machine information in HORCM_LDEV in the configuration definition file. Describe the virtual storage machine information in HORCM_LDEV in the configuration definition file. Describe the virtual storage machine information in HORCM_LDEV in the configuration definition file. Describe the virtual storage machine information in HORCM_LDEV in the configuration definition file. Describe the virtual storage machine information in HORCM_LDEV in the configuration definition file. Describe the virtual storage machine information in HORCM_LDEV in the configuration definition file CCI functions

123 Commands How to issue the command to the virtual storage machine Remarks pairmon Describe the virtual storage machine information in HORCM_LDEV in the configuration definition file. raidscan Specify the virtual storage machine by the -s <seq#> option. The virtual storage machine can be specified regardless of the description contents of the configuration definition file. raidar Specify the virtual storage machine by a unit ID by the command option (-p <port>). Operation target when you specify the virtual storage machine by the raidcom command This topic shows operational objects when you specify the virtual storage machine by the raidcom command option (-s <seq#> or -u <unit ID>). If the operation target of the command is VSP G1000 when you specify the virtual storage machine, even if you specify the virtual storage machine for the command option (that is, -s <seq#> or -u <unit ID>), the option is ignored. When you do not specify the option (that is, -s <seq#> or -u <unit ID>), operational objects of all the raidcom command is VSP G1000s. --- You cannot specify a virtual storage machine by the -u <unit ID> option of the raidscan command. Use the -s <seq#> option. The raidar command has no option to specify a serial number nor a unit ID. Use the -p <port> option as "CL1-An" (specify a unit ID in n). raidqry --- The information of both VSP G1000 and the virtual storage machine is displayed. raidvchkscan Specify the virtual storage machine by the command option (-s <seq#> or -u <unit ID>). The virtual storage machine can be specified regardless of the description contents of the configuration definition file. --- horcctl Specify VSP G1000 information. If you specify the virtual storage machine information, error (No such control device) occurs. raidcom Specify the virtual storage machine by the command option (-s <seq#> or -u <unit ID>). The virtual storage machine can be specified regardless of the description contents of the configuration definition file. Some commands only (see Operation target when you specify the virtual storage machine by the raidcom command on page 3-51). Operation type Commands Operation target when you specify the virtual storage machine Copy group raidcom get copy_grp VSP G1000 raidcom add copy_grp VSP G1000 raidcom delete copy_grp VSP G1000 CCI functions 3 51

124 Operation type Commands Operation target when you specify the virtual storage machine Device group raidcom get device_grp VSP G1000 raidcom add device_grp VSP G1000 raidcom delete device_grp VSP G1000 External volume group raidcom get external_grp VSP G1000 raidcom add external_grp VSP G1000 raidcom delete external_grp VSP G1000 raidcom modify external_grp VSP G1000 raidcom disconnect external_grp VSP G1000 Host group raidcom get host_grp VSP G1000 raidcom add host_grp VSP G1000 raidcom delete host_grp VSP G1000 raidcom modify host_grp VSP G1000 WWN raidcom get hba_wwn VSP G1000 raidcom add hba_wwn VSP G1000 raidcom set hba_wwn VSP G1000 raidcom reset hba_wwn VSP G1000 Journal raidcom get journal VSP G1000 raidcom add journal VSP G1000 raidcom delete journal VSP G1000 raidcom modify journal VSP G1000 LDEV raidcom get ldev Virtual storage machine raidcom add ldev VSP G1000 raidcom delete ldev VSP G1000 raidcom modify ldev VSP G1000 raidcom extend ldev VSP G1000 raidcom initialize ldev VSP G1000 LUN raidcom get lun Virtual storage machine raidcom add lun Virtual storage machine raidcom delete lun Virtual storage machine External path raidcom get path VSP G1000 raidcom add path VSP G1000 raidcom delete path VSP G1000 raidcom disconnect path VSP G1000 raidcom check_ext_storage path VSP G1000 raidcom check_ext_storage external_grp VSP G1000 raidcom discover external_storage VSP G1000 raidcom discover lun VSP G CCI functions

125 Operation type Commands Operation target when you specify the virtual storage machine Pool raidcom get pool VSP G1000 raidcom get dp_pool VSP G1000 raidcom get snap_pool VSP G1000 raidcom add dp_pool VSP G1000 raidcom add snap_pool VSP G1000 raidcom delete pool VSP G1000 raidcom modify pool VSP G1000 raidcom reallocate pool VSP G1000 raidcom monitor pool VSP G1000 Port raidcom get port VSP G1000 raidcom modify port VSP G1000 RCU raidcom get rcu VSP G1000 raidcom add rcu VSP G1000 raidcom delete rcu VSP G1000 Logical path to RCU raidcom add rcu_path VSP G1000 raidcom delete rcu_path VSP G1000 Parity group raidcom get parity_grp VSP G1000 SSID raidcom get ssid VSP G1000 raidcom add ssid VSP G1000 raidcom delete ssid VSP G1000 Resource group raidcom get resource VSP G1000 raidcom add resource VSP G1000 raidcom delete resource VSP G1000 raidcom lock resource VSP G1000 raidcom unlock resource VSP G1000 raidcom map resource VSP G1000 raidcom unmap resource VSP G1000 CLPR raidcom get clpr VSP G1000 raidcom modify clpr VSP G1000 Thin Image raidcom get snapshot Virtual storage machine raidcom add snapshot Virtual storage machine raidcom delete snapshot Virtual storage machine raidcom modify snapshot Virtual storage machine CCI functions 3 53

126 Operation type Commands Operation target when you specify the virtual storage machine Server Priority Manager raidcom get spm_wwn VSP G1000 raidcom get spm_group VSP G1000 raidcom add spm_wwn VSP G1000 raidcom add spm_group VSP G1000 raidcom delete spm_wwn VSP G1000 raidcom delete spm_group VSP G1000 raidcom monitor spm_wwn VSP G1000 raidcom monitor spm_group VSP G1000 Others raidcom get command_status VSP G1000 raidcom reset command_status VSP G1000 raidcom get error_message VSP G CCI functions

127 4 Starting up CCI You can begin using the CCI software after you have installed the CCI software, set the command device, created the configuration definition file(s), and (for OpenVMS only) followed the porting requirements and restrictions. One or two instances of CCI can be used simultaneously in UNIX, Windows, and OpenVMS operating system environments. Starting up on UNIX systems Starting up on Windows systems Starting up on OpenVMS systems Starting CCI as a service (Windows systems) Starting up CCI 4 1

128 Starting up on UNIX systems One instance To start up one instance of CCI on a UNIX system: 1. Modify /etc/services to register the port name/number (service) of each configuration definition file. Make the port name/number the same on all servers: horcm xxxxx/udp xxxxx = the port name/number for horcm.conf 2. If you want CCI to start automatically each time the system starts up, add /etc/horcmstart.sh to the system automatic startup file (for example, /sbin/rc). 3. Execute the horcmstart.sh script manually to start the CCI instances: # horcmstart.sh 4. Set the log directory (HORCC_LOG) in the command execution environment as needed. 5. If you want to perform TrueCopy operations, do not set the HORCC_MRCF environment variable. If you want to perform ShadowImage operations, set the HORCC_MRCF environment variable for the CCI execution environment. For B shell: # HORCC_MRCF=1 # export HORCC_MRCF For C shell: # setenv HORCC_MRCF 1 # pairdisplay -g xxxx xxxx = group name Two instances To start up two instances of CCI on a UNIX system: 1. Modify /etc/services to register the port name/number (service) of each configuration definition file. The port name/number must be different for each CCI instance. horcm0 xxxxx/udp xxxxx = the port name/number for horcm0.conf horcm1 yyyyy/udp yyyyy = the port name/number for horcm1.conf 2. If you want CCI to start automatically each time the system starts up, add /etc/horcmstart.sh 0 1 to the system automatic startup file (for example, /sbin/rc). 3. Execute the horcmstart.sh script manually to start the CCI instances: # horcmstart.sh Set an instance number to the command execution environment: For B shell: 4 2 Starting up CCI

129 # HORCMINST=X # export HORCMINST X = instance number = 0 or 1 For C shell: # setenv HORCMINST X 5. Set the log directory (HORCC_LOG) in the command execution environment as needed. 6. If you want to perform TrueCopy operations, do not set the HORCC_MRCF environment variable. If you want to perform ShadowImage operations, set the HORCC_MRCF environment variable for the CCI execution environment. For B shell: # HORCC_MRCF=1 # export HORCC_MRCF For C shell: # setenv HORCC_MRCF 1 # pairdisplay -g xxxx xxxx = group name Starting up on Windows systems One instance To start up one instance of CCI on a Windows system: 1. Modify %windir%\system32\drivers\etc\services to register the port name/number (service) of the configuration definition file. Make the port name/number the same on all servers: horcm xxxxx/udp xxxxx = the port name/number of horcm.conf 2. If you want CCI to start automatically each time the system starts up, add \HORCM\etc\horcmstart to the system automatic startup file (for example, \autoexec.bat). 3. Execute the horcmstart script manually to start CCI: D:\HORCM\etc> horcmstart 4. Set the log directory (HORCC_LOG) in the command execution environment as needed. 5. If you want to perform TrueCopy operations, do not set the HORCC_MRCF environment variable. If you want to perform ShadowImage operations, set the HORCC_MRCF environment variable for the CCI execution environment: D:\HORCM\etc> set HORCC_MRCF=1 D:\HORCM\etc> pairdisplay -g xxxx xxxx = group name Two instances To start up two instances of CCI on a Windows system: Starting up CCI 4 3

130 1. Modify %windir%\system32\drivers\etc\services to register the port name/number (service) of the configuration definition files. Make sure that the port name/number is different for each instance: horcm0 xxxxx/udp xxxxx = the port name/number of horcm0.conf horcm1 xxxxx/udp xxxxx = the port name/number of horcm1.conf 2. If you want CCI to start automatically each time the system starts up, add \HORCM\etc\horcmstart 0 1 to the system automatic startup file (for example, \autoexec.bat). 3. Execute the horcmstart script manually to start CCI: D:\HORCM\etc> horcmstart Set an instance number to the command execution environment: D:\HORCM\etc> set HORCMINST=X X = instance number = 0 or 1 5. Set the log directory (HORCC_LOG) in the command execution environment as needed. 6. If you want to perform TrueCopy operations, do not set the HORCC_MRCF environment variable. If you want to perform ShadowImage operations, set the HORCC_MRCF environment variable for the CCI execution environment: D:\HORCM\etc> set HORCC_MRCF=1 D:\HORCM\etc> pairdisplay -g xxxx xxxx = group name Starting up on OpenVMS systems One instance To start up one instance of CCI on an OpenVMS system: 1. Create the configuration definition file. For a new installation, use the configuration definition sample file that is supplied (SYS$POSIX_ROOT:[HORCM.etc]horcm.conf). Make a copy of the file: $ COPY SYS$POSIX_ROOT:[HORCM.etc]horcm.conf SYS$POSIX_ROOT:[etc] Edit this file according to your system configuration using a text editor (for example, eve). Register the port name (service) of the configuration definition file in "SYS$SYSROOT:[ TCPIP$ETC]SERVICES.DAT ". horcm xxxxx/udp xxxxx = port number Use the same port number in all servers. The port number can be directly specified without registering it in "SYS$SYSROOT:[ TCPIP$ETC]SERVICES.DAT". 2. Manually execute the HORCM startup command. 4 4 Starting up CCI

131 $ spawn /nowait /process=horcm horcmstart Note: The subprocess (HORCM) created by SPAWN is terminated when the terminal is LOGOFF or the session is terminated. If you want an independent process to the terminal LOGOFF, use the "RUN / DETACHED" command. 3. Confirm the configuration. Set the log directory (HORCC_LOG) in the command execution environment as required. Note: If the log directory under SYS$POSIX_ROOT is shared with other nodes, the log directory of Horc Manager must be set for each node. The log directory of Horc Manager can be changed by setting the parameter of horcmstart. See the Command Control Interface Command Reference for information about horcmstart parameters. If you want to perform ShadowImage operations, set the environment variable (HORCC_MRCF). $ HORCC_MRCF:=1 $ pairdisplay -g xxxx xxxx = group name Note: If a system configuration change or a RAID configuration change causes this file to change, (for example, cache size change or microcode change), these changes will not take effect until you stop HORCM (horcmshutdown) and restart HORCM (horcmstart). Use the "-c" option of the pairdisplay command to verify that there are no configuration errors. Two instances To start up two instances of CCI on an OpenVMS system: 1. Create the configuration definition files. For a new installation, use the configuration definition sample file that is supplied (SYS$POSIX_ROOT:[HORCM.etc]horcm.conf). Copy the file twice, once for each instance. $ COPY SYS$POSIX_ROOT:[HORCM.etc]horcm.conf SYS$POSIX_ROOT:[etc] horcm0.conf $ COPY SYS$POSIX_ROOT:[HORCM.etc]horcm.conf SYS$POSIX_ROOT:[etc] horcm1.conf Edit these two files according to your system configuration using a text editor (for example, eve). Register the port name (service) of the configuration definition file in "SYS$SYSROOT:[ TCPIP$ETC]SERVICES.DAT". horcm0 xxxxx/udp xxxxx = port number horcm1 yyyyy/udp yyyyy = port number Each instance should have a unique port number. The port number can be directly specified without registering it in "SYS$SYSROOT:[ TCPIP$ETC]SERVICES.DAT". 2. Execute the HORCM startup command. Starting up CCI 4 5

132 $ spawn /nowait /process=horcm0 horcmstart 0 $ spawn / nowait /process=horcm1 horcmstart 1 Note: The subprocess (HORCM) created by SPAWN is terminated when the terminal is LOGOFF or the session is terminated. If you want an independent process to the terminal LOGOFF, use "RUN /DETACHED" command. 3. Set the HORCM instance numbers in the environment in which the command is to be executed: $ HORCMINST:=X X = instance number (0 or 1) 4. Confirm the configuration using a CCI command. Set the log directory (HORCC_LOG) in the command execution environment as required. Note: If the log directory under SYS$POSIX_ROOT is shared with other nodes, the log directory of Horc Manager must be set for each node. The log directory of Horc Manager can be changed by setting the parameter of horcmstart. See the Command Control Interface Command Reference for information about horcmstart parameters. If you want to perform ShadowImage operations, set the environment variable (HORCC_MRCF). $ HORCC_MRCF:=1 $ pairdisplay - g xxxx xxxx denotes a group name. Note: If a system configuration change or a RAID configuration change causes this file to change (for example, cache size change, microcode change), these changes will not take effect until you stop HORCM (horcmshutdown 0 1) and restart HORCM (horcmstart 0 and horcmstart 1). Use the "-c" option of the pairdisplay command to verify that there are no configuration errors. Starting CCI as a service (Windows systems) Usually, CCI (HORCM) is started by executing the startup script from the Windows services. However, in the VSS environment, there is no interface to automatically start CCI. CCI provides the svcexe.exe command and a sample script file (HORCM0_run.txt) so that CCI can be started automatically as a service. C:\HORCM\tool\>svcexe Usage for adding [HORCM_START_SVC]: svcexe /A=command_path for deleting [HORCM_START_SVC]: svcexe /D for specifying a service: svcexe /S=service_name for dependent services: svcexe / C=service_name,service_name This command example uses HORCM0 for registering the service name for HORCM instance#0: Example for adding [HORCM0]: svcexe /S=HORCM0 "/ A=C:\HORCM\tool\svcexe.exe" for deleting [HORCM0]: svcexe /S=HORCM0 /D 4 6 Starting up CCI

133 for starting [HORCM0]: :[1] make a C:\HORCM\tool\HORCM0_run.txt file. :[2] set a user account to this service. :[3] confirm to start using horcmstart 0. :[4] confirm to stop using horcmshutdown 0. :[5] start as a service by net start HORCM0. Performing Additional Configuration Tasks 1. Registering the CCI (HORCM) instance as a service. The system administrator must add the CCI instance using the following command: C:\HORCM\tool\>svcexe /S=HORCM0 "/ A=C:\HORCM\tool\svcexe.exe" 2. Customizing a sample script file. The system administrator must customize the sample script file (HORCM0_run.txt) according to the CCI instance. For details, see the descriptions in the HORCM0_run.txt file. 3. Setting the user account. The system administrator must set the user account for the CCI administrator as needed. When using the GUI, use "Administrative Tools - Services - Select HORCM0 - Logon". When using the CUI, use "sc config" command as follows: C:\HORCM\tool\>sc config HORCM0 obj= AccountName password= password If the system administrator uses the default account (LocalSystem), add "HORCM_EVERYCLI=1": # **** For INSTANCE# X, change to HORCMINST=X as needed **** START: set HORCM_EVERYCLI=1 set HORCMINST=0 set HORCC_LOG=STDERROUT C:\HORCM\etc\horcmstart.exe exit 0 4. Starting the CCI instance from the service. After you have confirmed starting and stopping using "horcmstart 0" and "horcmshutdown 0", you must verify that HORCM0 starts from the service and that HORCM0 started automatically from REBOOT, using the following command: C:\HORCM\tool\>net start HORCM0 5. Stopping CCI instance as a service. Instead of using the "horcmshutdown 0" command, you must use the following command to stop HORCM0: C:\HORCM\tool\>net stop HORCM0 (By using the "horcmshutdown 0" command, the script written into HORCM0_run.txt will automatically restart HORCM0). Starting up CCI 4 7

134 4 8 Starting up CCI

135 5 Provisioning operations with CCI This chapter describes storage provisioning operations with CCI. About provisioning operations Available provisioning operations Available provisioning operation (specifying device group) Common operations when executing provisioning operations Resource group operations Internal volume operations Virtual volume (Dynamic Provisioning) operations Virtual volume (Dynamic Provisioning for Mainframe) operations Virtual volume (Dynamic Tiering) operations External volume operations Virtual Partition Manager operations Server Priority Manager operations Virtual storage machine operations (VSP G1000 only) Provisioning operations with CCI 5 1

136 About provisioning operations Provisioning operations can be performed using CCI. For details about provisioning, see the Provisioning Guide for the storage system. Note: The operation of refreshing window on Hitachi Storage Navigator or SVP might be delayed while executing provisioning operation on CCI. During maintenance work on the storage system (SVP in modify mode), the command is rejected (2E10, 8000). Overview of the configuration setting command CCI functions enable provisioning operations such as host setting, LDEV creation, and device group creation. These operations are required for performing the data replication operations. The is done by using the configuration setting command. The configuration setting command is specified using the following syntax: raidcom <action> <resource> <parameter> The content of operation such as add or delete is specified in the action, and a resource object such as LDEV or path is specified in the resource. The necessary value to operate the resource object is specified in the parameter. For the details about contents of specification for the configuration setting command, see Command Control Interface Command Reference. Some provisioning operations take much processing time. Therefore CCI provides two ways to execute the configuration setting command: synchronously and asynchronously. Figure 5-1 Synchronous and asynchronous command processing The processing difference between these two command types are described in Synchronous command processing on page 5-3 and Asynchronous command processing on page Provisioning operations with CCI

137 Synchronous command processing In addition to the replication commands, the process is executed by synchronizing with a command execution, and then returning a response after the processing is completed. When an error occurs, the error is returned to CCI at each occurrence. Asynchronous command processing When an asynchronous command is executed, the command is received at the storage system, and a response is returned before the processing is executed. The actual processing is executed asynchronously with command input. The completion of the asynchronous command processing can be checked with the raidcom get command_status command. Executing raidcom get command_status command after executing an asynchronous command, the raidcom get command_status command is terminated after completing all the asynchronous command processing. When an error occurs by executing asynchronous command, the error information, such as the total number of errors or error code (SSB1 and SSB2), is provided. After executing the asynchronous command, execute raidcom get command_status command to check the error information if the asynchronous command processing completed normally. Error codes SSB1 and SSB2 are stored only at the first error occurrence. For the second and subsequent occurrences, only the number of the error occurrence is stored with no error code. Therefore, before executing an asynchronous command, reset the error information in the storage system using the raidcom reset command_status command. You can check the information in SSB1 and SSB2 by using the raidcom get error_message command. In a part of asynchronous command processing, the multiple commands received by the host are executed at a time. Therefore, the total number of errors may not correspond with the unexecuted commands. If the error occurred in asynchronous commands, verify the system configuration by the reference commands. For details about the reference commands, see Available provisioning operations on page 5-5. When executing an asynchronous command, execute a command or a script with the following procedures. 1. Execute a raidcom reset command_status command. Resets the error information of asynchronous command in the storage system. 2. Execute an asynchronous command. Executes the asynchronous command. 3. Execute a raidcom get command_status command. Checks if all the asynchronous command processing are done or if no error is occurred. Provisioning operations with CCI 5 3

138 Asynchronous commands The asynchronous commands associated with the configuration setting command provide provisioning functions. The table lists the functions performed by asynchronous commands and describes the required syntax. Table 5-1 Asynchronous commands of the configuration setting command Function Command syntax Blocking an LDEV raidcom modify ldev -ldev_id <ldev#> -status blk Adding an LDEV raidcom add ldev {-parity_grp_id <gno-sgno> - external_grp_id <gno-sgno> -pool {<pool ID#> <pool naming> snap}} - ldev_id <ldev#> { -capacity <size> -offset_capacity <size> -cylinder <size>} [-emulation <emulation type>][-location <lba>][-mp_blade_id <mp#>] Deleting an LDEV raidcom delete ldev {-ldev_id <ldev#> -grp_opt <group option> -device_grp_name <device group name> [<device name>]} LDEV Quick Format raidcom initialize ldev {-ldev_id <ldev#> -grp_opt <group option> -device_grp_name <device group name> [<device name>]} -operation qfmt Restoring an LDEV raidcom modify ldev -ldev_id <ldev#> -status nml Creating virtual volume for Dynamic Provisioning, Dynamic Provisioning for Mainframe, Dynamic Tiering, or Copy-on-Write Snapshot Deleting virtual volume for Dynamic Provisioning, Dynamic Tiering, or Copy-on-Write Snapshot Creating a pool /adding a pool volume for Dynamic Provisioning or Dynamic Provisioning for Mainframe Creating a pool /adding a pool volume for Snapshot Deleting or shrinking a pool raidcom add ldev -pool {<pool ID#> <pool naming> snap} - ldev_id <ldev#> -capacity <size> raidcom delete ldev {-ldev_id <ldev#> -grp_opt option> -device_grp_name <device group name>[<device name>]} <group raidcom add dp_pool {{-pool_id <pool ID#> [-pool_name <pool naming>] -pool_name <pool naming>[-pool_id <pool ID#>]} -pool_id <pool ID#> -pool_name <pool naming>} {- ldev_id <ldev#> [-cnt<count>] -grp_opt <group option> - device_grp_name <device group name> [<device name>]}[ - user_threshold <threshold_1> [<threshold_2>] ] raidcom add snap_pool {{-pool_id <pool ID#> [-pool_name <pool naming>] -pool_name <pool naming>[-pool_id <pool ID#>]} -pool_id <pool ID#> -pool_name <pool naming>}} {-ldev_id <ldev#> [-cnt<count>] -grp_opt <group option> -device_grp_name <device group name> [<device name>]}[- user_threshold <%> ] raidcom delete pool -pool {<pool ID#> <pool naming>}[-ldev <ldev#>] Releasing a blocked pool raidcom modify pool -pool {<pool ID#> <pool naming>} - status nml RCU registration raidcom add rcu -cu_free <serial#> <id> <pid> -mcu_port <port> -rcu_port <port> RCU logical path addition raidcom add rcu_path -cu_free <serial#> <id> <pid> -mcu_port <port> -rcu_port <port> RCU deletion raidcom delete rcu -cu_free <serial#> <id> <pid> 5 4 Provisioning operations with CCI

139 Function Command syntax RCU logical path deletion raidcom delete rcu_path -cu_free <serial#> <id> <pid> - mcu_port <port> -rcu_port <port> Creating journal/ Registering journal volume the journal Deleting journal/ Deleting journal volume from the journal Restoration of path for the external path. Help on configuration setting commands To see the configuration setting command help, execute any command using the -h option, for example, raidcom - h. raidcom -h LDEV nickname function As a function of configuration setting command, a nickname can be set for each LDEV. The details of the definition for the LDEV nickname function are shown below. The maximum length of a name is 32 characters. For one LDEV, one nickname can be defined. A nickname can be defined as follows: Available provisioning operations raidcom add journal -journal_id <journal ID#> {-ldev_id <ldev#> [-cnt <count>] -grp_opt <group option> - device_grp_name <device group name> [<device name>]} raidcom delete journal -journal_id <journal ID#> [-ldev_id <ldev#> -grp_opt <group option> -device_grp_name <device group name> [<device name>]] raidcom check_ext_storage path -path_grp <path group#> - port <port> -external_wwn <wwn strings> Setting the external path raidcom add path -path_grp <path group#> -port <port> - external_wwn <wwn strings> Mapping the external volume raidcom add external_grp -path_grp <path group#> - external_grp_id <gno-sgno> -port <port> -external_wwn <wwn strings> -lun_id <lun#> [-emulation <emulation type>] Deleting the external path raidcom delete path -path_grp <path group#> -port <port> - external_wwn <wwn strings> Releasing the mapping of external volume raidcom delete external_grp -external_grp_id <gno-sgno> Stopping the use of paths to the external volume raidcom disconnect path -path_grp <path group#> -port <port> -external_wwn <wwn strings> raidcom modify ldev -ldev_id <ldev#> -ldev_name <ldev naming> The following provisioning operations can be performed using CCI. Operation type Description Corresponding command Login and logout Log in. raidcom -login <user_name> <password> Log out. raidcom -logout Provisioning operations with CCI 5 5

140 Operation type Description Corresponding command Resource Lock resource. raidcom lock resource -resource_name <resource group name > [-time <time(sec)>] Host (see the Provisioning Guide for the storage system) Port (see the Provisioning Guide for the storage system) Unlock resource. Display resource group information. Add resource group. Delete resource group. Create host group. Set host mode. Register a host to host group. Delete host group. Display host group information. Set port. Set port attribute. Display port information. raidcom unlock resource -resource_name <resource group name > raidcom get resource raidcom add resource -resource_name <resource group name> [-resource_id <resource group_id > -ldev_id <ldev#> -port <port#> -port <port#> <host group name> -parity_grp_id <gno-sgno> -external_grp_id <gno-sgno>] raidcom delete resource -resource_name <resource group name> [-ldev_id <ldev#> -port <port#> -port <port#> <host group name> -parity_grp_id <gno-sgno> -external_grp_id <gno-sgno>] raidcom add host_grp -port <port> -host_grp_name <host group name> raidcom modify host_grp -port <port> [<host group name>] -host_mode < host mode> [-host_mode_opt <host mode option> ] raidcom add hba_wwn -port <port> [<host group name>] -hba_wwn <WWN strings> raidcom delete host_grp -port <port> [<host group name>] raidcom get host_grp -port <port> [<host group name>] raidcom modify port -port <port>{[-port_speed <value>] [-loop_id<value>] [-topology <topology>] [-security_switch < y/n >]} raidcom modify port -port <port> -port_attribute <port attribute> raidcom get port [-port <port>] 5 6 Provisioning operations with CCI

141 Operation type Description Corresponding command Internal volume (see the Provisioning Guide for the storage system) Create LDEV. Display LDEV information. Display parity group information. Define SSID. raidcom add ldev {-parity_grp_id <gno-sgno> - external_grp_id <gno-sgno> -pool {<pool ID#> <pool naming> snap}} -ldev_id <ldev#> {-capacity <size> -offset_capacity <size> -cylinder <size>} [-emulation <emulation type>][-location <lba>] [-mp_blade_id <mp#>] raidcom get ldev {-ldev_id <ldev#> [-cnt <count>] -grp_opt <group option> -device_grp_name <device group name> [<device name>]} [-key <keyword>] raidcom get parity_grp [-parity_grp_id <gno-sgno>] raidcom add ssid -rcu <serial#> <mcu#> <rcu#> <id> -ssid <ssid> raidcom delete ssid -rcu <serial#> <mcu#> <rcu#> -ssid <ssid> Provisioning operations with CCI 5 7

142 Operation type Description Corresponding command Virtual volume (Dynamic Provisioning, Dynamic Provisioning for Mainframe, Dynamic Tiering, Copy-on-Write Snapshot) (see the Provisioning Guide for the storage system) Create pool for Dynamic Provisioning or Dynamic Provisioning for Mainframe. Create pool for Copy-on- Write Snapshot. Display pool information for Dynamic Provisioning, Dynamic Provisioning for Mainframe, Dynamic Tiering, or Copy-on-Write Snapshot. Delete pool for Dynamic Provisioning, Dynamic Provisioning for Mainframe, Dynamic Tiering, or Copy-on-Write Snapshot. Change the threshold value of a pool for Dynamic Provisioning, Dynamic Provisioning for Mainframe, Dynamic Tiering, or Copy-on-Write Snapshot. Restore a pool for Dynamic Provisioning, Dynamic Provisioning for Mainframe, Dynamic Tiering, or Copy-on-Write Snapshot. Set the maximum rate of subscription of a pool for Dynamic Provisioning, Dynamic Provisioning for Mainframe, Dynamic Tiering. raidcom add dp_pool {{-pool_id <pool ID#> [-pool_name <pool naming>] -pool_name <pool naming>[-pool_id <pool ID#>]} -pool_id <pool ID#> -pool_name <pool naming>}} {-ldev_id <ldev#> [-cnt<count>] -grp_opt <group option> -device_grp_name <device group name> [<device name>]}[-user_threshold <threshold_1> [<threshold_2>] ] raidcom add snap_pool {{-pool_id <pool ID#> [-pool_name <pool naming>] -pool_name <pool naming>[-pool_id <pool ID#>]} -pool_id <pool ID#> -pool_name <pool naming>}} {-ldev_id <ldev#> [-cnt<count>] -grp_opt <group option> -device_grp_name <device group name> [<device name>]} [-user_threshold <%> ] raidcom get pool [-key <keyword>] raidcom delete pool -pool {<pool ID#> <pool naming>} raidcom modify pool -pool {<pool ID#> <pool naming>} -user_threshold <threshold_1> [<threshold_2>] raidcom modify pool -pool {<pool ID#> <pool naming>} -status nml raidcom modify pool -pool {<pool ID#> <pool naming>} -subscription <%> 5 8 Provisioning operations with CCI

143 Operation type Description Corresponding command Change the pool for Dynamic Provisioning to the pool for Dynamic Tiering. Change the pool for Dynamic Tiering to the pool for Dynamic Provisioning. Set the newly allocation free space percentage of the pool for Dynamic Tiering. Create virtual volume for Dynamic Provisioning, Dynamic Provisioning for Mainframe, Dynamic Tiering, or Copy-on-Write Snapshot. Extend capacity of virtual volume for Dynamic Provisioning, Dynamic Provisioning for Mainframe, Dynamic Tiering. Set enabled or disabled of virtual volume tier reallocation for Dynamic Tiering. Release a page of virtual volume for Dynamic Provisioning, Dynamic Provisioning for Mainframe, Dynamic Tiering. Display the information of a pool for Dynamic Provisioning, Dynamic Provisioning for Mainframe, Dynamic Tiering. Display the information of a pool for Copy-on-Write Snapshot. Extend the capacity of a pool for Dynamic Provisioning, Dynamic Provisioning for Mainframe, Dynamic Tiering. raidcom modify pool -pool {<pool ID#> <pool naming>} -pool_attribute dt_manual raidcom modify pool -pool {<pool ID#> <pool naming>} -pool_attribute dp raidcom modify pool -pool {<pool ID#> <pool naming>} -tier <Tier number><ratio> raidcom add ldev -pool {<pool ID#> <pool naming> snap} -ldev_id <ldev#> -capacity <size> [-emulation <emulation type>] [-location <lba>][-mp_blade_id <mp#>] raidcom extend ldev{-ldev_id <ldev#> -grp_opt <group option> -device_grp_name <device group name> [<device name>]} -capacity <size> raidcom modify ldev -ldev_id <ldev#> -status {enable_reallocation disable_reallocation} raidcom modify ldev -ldev_id <ldev#> -status discard_zero_page raidcom get dp_pool [ -key <keyword>] raidcom get snap_pool raidcom add dp_pool {{-pool_id <pool ID#> [-pool_name <pool naming>] -pool_name <pool naming>[-pool_id <pool ID#>]} -pool_id <pool ID#> -pool_name <pool naming>}} {-ldev_id <ldev#> [-cnt<count>] -grp_opt <group option> -device_grp_name <device group name> [<device name>]}[-user_threshold <threshold_1> [<threshold_2>] ] Provisioning operations with CCI 5 9

144 Operation type Description Corresponding command LU path (see the Provisioning Guide for the storage system) Extend the capacity of a pool for Copy-on-Write Snapshot. Start or stop the performance monitor for Dynamic Tiering Start or stop the tier reallocation of a pool for Dynamic Tiering. Set LU path. Delete LU path. Display LU path information. raidcom add snap_pool {{-pool_id <pool ID#> [-pool_name <pool naming>] -pool_name <pool naming>[-pool_id <pool ID#>]} -pool_id <pool ID#> -pool_name <pool naming>}} {-ldev_id <ldev#> [-cnt<count>] -grp_opt <group option> -device_grp_name <device group name> [<device name>]} [-user_threshold <%> ] raidcom monitor pool -pool {<pool ID#> <pool naming>} -operation <type> raidcom reallocate pool -pool {<pool ID#> <pool naming>} -operation <type> raidcom add lun -port <port> [<host group name>] {-ldev_id <ldev#> [-lun_id<lun#>] -grp_opt <group option> -device_grp_name <device group name> [<device name>]} raidcom delete lun -port <port> [<host group name>] {-lun_id <lun#> -ldev_id <ldev#> -grp_opt <group option> -device_grp_name <device group name> [<device name>]} raidcom get lun -port <port> [<host group name>] 5 10 Provisioning operations with CCI

145 Operation type Description Corresponding command External volume (Universal Volume Manager) (see the Provisioning Guide for the storage system) Search external storage. Search external volume. Map external volume. Disconnect the connection for external volume. Check the connection for external volume and restore it. Unmap external volume. Display mapped external volume information. Create LDEV in external volume. Display LDEV information created in external volume. Change cache mode of external volume. Control cache write of external volume. Modify ownership MP Blade of external volume. Add external path. Delete external path. Display external path information. Stop the usage of external path. Restore the external path. Define SSID. raidcom discover external_storage -port <port> raidcom discover lun -port <port> -external_wwn <wwn strings> raidcom add external_grp -path_grp <path group#> -external_grp_id <gno-sgno> -port <port> -external_wwn <wwn strings> -lun_id <lun#> [-emulation <emulation type>] raidcom disconnect external_grp {-external_grp_id <gno-sgno> -ldev_id <ldev#>} raidcom check_ext_storage external_grp {-external_grp_id <gno-sgno> -ldev_id <ldev#>} raidcom delete external_grp -external_grp_id <gno-sgno> raidcom get external_grp [-external_grp_id <gno-sgno>] raidcom add ldev - external_grp_id <gno-sgno> -ldev_id <ldev#> -capacity <size> [-emulation <emulation type>] [-location <lba>][-mp_blade_id <mp#>] raidcom get ldev {-ldev_id <ldev#> [-cnt <count>] -grp_opt <group option> -device_grp_name <device group name> [<device name>]} [-key <keyword>] raidcom modify external_grp -external_grp_id <gno-sgno> -cache_mode < y n > raidcom modify external_grp -external_grp_id <gno-sgno> -cache_inflow < y n > raidcom modify external_grp -external_grp_id <gno-sgno> -mp_blade_id <mp#> raidcom add path -path_grp <path group#> -port <port> -external_wwn <wwn strings> raidcom delete path -path_grp <path group#> -port <port> -external_wwn <wwn strings> raidcom get path [-path_grp <path group#>] raidcom disconnect path -path_grp <path group#> -port <port> -external_wwn <wwn strings> raidcom check_ext_storage path -path_grp <path group#> -port <port> -external_wwn <wwn strings> raidcom add ssid -rcu <serial#> <mcu#> <rcu#> <id> -ssid <ssid> raidcom delete ssid -rcu <serial#> <mcu#> <rcu#> -ssid <ssid> Provisioning operations with CCI 5 11

146 Operation type Description Corresponding command Maintenance Host LDEV Device group Copy group Add WWN of host path adapter. Delete WWN of host path adapter. Set nickname for WWN of host path adapter. Delete nickname from WWN of host path adapter. Display registered WWN information of host path adapter. raidcom add hba_wwn -port <port> [<host group name>] -hba_wwn <WWN strings> raidcom delete hba_wwn -port <port> [<host group name>] -hba_wwn <WWN strings> raidcom set hba_wwn -port <port>[<host group name>] -hba_wwn <WWN strings> -wwn_nickname <WWN Nickname> raidcom reset hba_wwn -port <port>[<host group name>] -hba_wwn <WWN strings> raidcom get host_grp -port <port> [<host group name>] Blockade or restore LDEV. raidcom modify ldev -ldev_id <ldev#> -status discard_zero_page Create nickname for LDEV. Modify allocated MP Blade to LDEV. Format LDEV. Create device group. Delete LDEV from device group. Display device group information. Create copy group. Delete copy group. Display copy group information. raidcom modify ldev -ldev_id <ldev#> -ldev_name <ldev naming> raidcom modify ldev -ldev_id <ldev#> -mp_blade_id <mp#> raidcom initialize ldev {-ldev_id <ldev#> -grp_opt <group option> -device_grp_name <device group name> [<device name>]} -operation <type> raidcom add device_grp -device_grp_name <ldev group name> <device name> -ldev_id <ldev#> [-cnt <count>] raidcom delete device_grp -device_grp_name <device group name> -ldev_id <ldev#> [-cnt <count>] raidcom get device_grp [-device_grp_name <device group name>] raidcom add copy_grp -copy_grp_name <copy group name> <device group name> [device group name] [-mirror_id <mu#> -journal_id <journal ID#>] raidcom delete copy_grp -copy_grp_name <copy group name> raidcom get copy_grp CLPR View CLPR configuration. raidcom get clpr Modify CLPR (migrate LDEV, parity group, external group). raidcom modify clpr 5 12 Provisioning operations with CCI

147 Operation type Description Corresponding command Remote copy environment RCU (see the manuals for TC, TCz, UR, and URz) Register RCU. Delete RCU. Set RCU attribute. raidcom add rcu -cu_free <serial#> <id> <pid> -mcu_port <port> -rcu_port <port> raidcom delete rcu -cu_free <serial#> <id> <pid> raidcom modify rcu -cu_free <serial#> <id> <pid> -rcu_option <mpth> <rto> <rtt> Display RCU information. raidcom get rcu [-cu_free <serial#> <id> <pid>] RCU path (see the manuals for TC, TCz, UR, and URz) Add RCU logical path. Delete RCU logical path. raidcom add rcu_path -cu_free <serial#> <id> <pid> -mcu_port <port> -rcu_port <port> raidcom delete rcu_path -cu_free <serial#> <id> <pid> -mcu_port <port> -rcu_port <port> Journal (see the manuals for UR and URz) Register journal volume to Journal. Delete journal volume from Journal/ Delete journal. raidcom add journal -journal_id <journal ID#> {-ldev_id <ldev#> [-cnt <count>] -grp_opt <group option> -device_grp_name <device group name> [<device name>]} [-mp_blade_id <mp#> -timer_type <timer type> ] raidcom delete journal -journal_id <journal ID#> [-ldev_id <ldev#> -grp_opt <group option> -device_grp_name <device group name> [<device name>]] Change the Universal Replicator option to be used at Journal. raidcom modify journal -journal_id <journal ID#> {[-data_overflow_watch<time>] [-cache_mode <y/n>][-timer_type <type>]} -path_blocked_watch <time> [-mirror_id <mu#>] -mp_blade_id <mp#> Display journal information. raidcom get journal [ -key <keyword>]raidcom get journal[t] Available provisioning operation (specifying device group) Summary CCI can execute provisioning operation by specifying a device group. When specifying a device group, the LDEVs belonging to the device group can be operated at a time. For details about device group, see LDEV grouping function on page The following table lists the provisioning operations that can be executed by specifying a device group. Table 5-2 Performing provisioning operations by specifying a device group Contents of operation Register a journal group to a journal Delete a journal group from a journal/delete a journal Delete an LDEV/V-VOL Command raidcom add journal raidcom delete journal raidcom delete ldev Provisioning operations with CCI 5 13

148 Contents of operation Command Operation method Extend the capacity of V-VOL for Dynamic Provisioning, Dynamic Provisioning for Mainframe, Dynamic Tiering Display the LDEV information Format an LDEV Create an LU path Delete an LU path Create a pool for Copy-on-Write Snapshot Specify the name of device group (max: 32 characters) and the device name in the device group (max: 32 characters), and execute a command. The following shows an example to map the LDEV to the LUN by specifying a device group. When the both of device group name and device name, the operation is executed for the LDEV that matches to the specified device name in the device group. If the device name is omitted to specify, the operation is executed for all of the LDEVs belonging to the device group. Information of the device group to be operated raidcom extend ldev raidcom get ldev raidcom initialize ldev raidcom add lun raidcom delete lun raidcom add snap_pool Extend the capacity of a pool for Copy-on-Write Snapshot raidcom add snap_pool Create a pool for Dynamic Provisioning, Dynamic Provisioning for Mainframe Extend the capacity of a pool for Dynamic Provisioning, Dynamic Provisioning for Mainframe, Dynamic Tiering Create a resource group Delete a resource group C:\HORCM\etc>raidcom get device_grp -device_grp_name grp1 LDEV_GROUP LDEV_NAME LDEV# Serial# grp1 data grp1 data grp1 data grp1 data raidcom add dp_pool raidcom add dp_pool raidcom add resource raidcom delete resource Result The following shows the result when the raidcom add lun command is executed by specifying device group name: grp1, and device name: data Provisioning operations with CCI

149 C:\HORCM\etc>raidcom add lun -port CL8-A -grp_opt ldev -device_grp_name grp1 data0 GROUP = grp1, DEVICE = data0, UnitID = 0, LDEV = 17000(0x4268)[1], PORT = CL8-A, LUN = none: raidcom: LUN 0(0x0) will be used for adding. done GROUP = grp1, DEVICE = data0, UnitID = 0, LDEV = 17001(0x4269)[1], PORT = CL8-A, LUN = none: raidcom: LUN 1(0x1) will be used for adding. done C:\HORCM\etc>raidcom get lun -port CL8-A-0 PORT GID HMD LUN NUM LDEV CM Serial# HMO_BITs CL8-A 0 LINUX/IRIX CL8-A 0 LINUX/IRIX The following shows the result when the raidcom add lun command is executed by specifying device group name: grp1 only (omitting device name). C:\HORCM\etc>>raidcom add lun -port CL8-A -grp_opt ldev -device_grp_name grp1 GROUP = grp1, DEVICE = data0, UnitID = 0, LDEV = 17000(0x4268)[1], PORT = CL8-A, LUN = none : raidcom: LUN 0(0x0) will be used for adding. done GROUP = grp1, DEVICE = data0, UnitID = 0, LDEV = 17001(0x4269)[1], PORT = CL8-A, LUN = none : raidcom: LUN 1(0x1) will be used for adding. done GROUP = grp1, DEVICE = data1, UnitID = 0, LDEV = 17002(0x426A)[1], PORT = CL8-A, LUN = none : raidcom: LUN 2(0x2) will be used for adding. done GROUP = grp1, DEVICE = data1, UnitID = 0, LDEV = 17003(0x426B)[1], PORT = CL8-A, LUN = none : raidcom: LUN 3(0x3) will be used for adding. done C:\HORCM\etc>>raidcom get lun -port CL8-A-0 PORT GID HMD LUN NUM LDEV CM Serial# HMO_BITs CL8-A 0 LINUX/IRIX CL8-A 0 LINUX/IRIX CL8-A 0 LINUX/IRIX CL8-A 0 LINUX/IRIX The following shows the example for specifying device groups and creating journal. Provisioning operations with CCI 5 15

150 C:\HORCM\etc>raidcom add device_grp -device_grp_name dg_jnl1 data1 - ldev_id C:\HORCM\etc>raidcom get device_grp LDEV_GROUP Serial# dg_jnl C:\HORCM\etc>raidcom get device_grp -device_grp_name dg_jnl1 LDEV_GROUP LDEV_NAME LDEV# Serial# dg_jnl1 data dg_jnl1 data dg_jnl1 data dg_jnl1 data C:\HORCM\etc>raidcom add journal -journal_id 2 -grp_opt ldev - device_grp_name dg_jnl1 GROUP = dg_jnl1, DEVICE = data1, UnitID = 0, LDEV = 512(0x0200)[1], PORT = none, LUN = none :done GROUP = dg_jnl1, DEVICE = data1, UnitID = 0, LDEV = 513(0x0201)[1], PORT = none, LUN = none :done GROUP = dg_jnl1, DEVICE = data1, UnitID = 0, LDEV = 514(0x0202)[1], PORT = none, LUN = none :done GROUP = dg_jnl1, DEVICE = data1, UnitID = 0, LDEV = 515(0x0203)[1], PORT = none, LUN = none :done Common operations when executing provisioning operations When executing each provisioning operation, log in, log out, lock resources, unlock resources, and view resource group information using the following operational flow. Step Summary Contents of operation Command of Execution 1 Logging in Specify your user name and password to log in. 2 Locking resource group 3 Provisioning operations 4 Unlocking resource group 5 Displaying a resource group information Lock the resource group. Execute provisioning operations. Unlock the resource group. Displays a resource group information, and confirms a resource group information and a lock information. raidcom -login <user_name> <password> raidcom lock resource -resource_name <resource group name > [-time <time(sec)>] -- raidcom unlock resource -resource_name <resource group name> raidcom get resource 6 Logging out Log out. raidcom -logout 5 16 Provisioning operations with CCI

151 Resource group operations Creating resource groups To create resource groups, perform the following provisioning operations. Step Operation Description Command 1 Creating resource groups 2 Allocationg resources to resource groups 3 Displaying a resource group information Creates resource groups. Specifies resources that are allocated to meta_resource (resource group), and allocates resources to created resource groups. Displays a resource group information, and confirms execution results of commands. raidcom add resource -resource_name <resource group name> raidcom add resource -resource_name <resource group name> [-ldev_id <ldev#> -port <port#> -port <port#> <host group name> -parity_grp_id <gno-sgno> -external_grp_id <gno-sgno>] raidcom get resource Deleting resource groups To delete resource groups, perform the following provisioning operations. Step Operation Description Command 1 Deleting resources that are allocated to resource groups. 2 Confirming resource deletions 3 Deleting resource groups 4 Displaying resource group information Deletes resources that are allocated to resource groups. In other words, this operation allocates resources to resource group: meta_resource. Confirms that resources are not allocated to resource groups that you want to delete. At that time, allocation of resources to the resource group: meta_resource must be finished. Deletes resource groups. Displays resource group information and confirms results of command executions. raidcom delete resource -resource_name <resource group name> [-ldev_id <ldev#> -port <port#> -port <port#> <host group name> -parity_grp_id <gno-sgno> -external_grp_id <gno-sgno>] raidcom get resource raidcom delete resource -resource_name <resource group name> raidcom get resource Provisioning operations with CCI 5 17

152 Allocating resources that are allocated to resource groups to other resource groups Execution example When you want to allocate resources that are already allocated to resource groups to other resource groups, resources must be once allocated to resource group: meta_resource. After that, allocate resources to the resource groups that you want to allocate. LDEVs that configure journals, pools, LUSEs or device groups must be allocated to resource groups particularly. The following shows the necessary provisioning operations. Step Operation Description Command 1 Deleting resources that are allocated to resource groups 2 Confirming resource deletions 3 Allocating resources to resource groups 4 Displaying resource group information Deletes resources that are allocated to resource groups. In other words, this operation allocates resources to resource group: meta_resource. Confirms that resources are not allocated to resource groups that you want to delete. At that time, allocation of resources to the resource group: meta_resource must be finished. Specifies resources that are allocated to meta_resource (resource group), and allocates resources to resource groups. Displays resource group information and confirms results of command executions. raidcom delete resource -resource_name <resource group name> [-ldev_id <ldev#> -port <port#> -port <port#> <host group name> -parity_grp_id <gno-sgno> -external_grp_id <gno-sgno>] raidcom get resource raidcom add resource -resource_name <resource group name> [-ldev_id <ldev#> -port <port#> -port <port#> <host group name> -parity_grp_id <gno-sgno> -external_grp_id <gno-sgno>] raidcom get resource LDEVs that are allocated to journals or pools must be migrated by users. We recommend that you register LDEVs that are allocated to journals or pools as device groups, and then operate after specifying them by the device groups. The following shows the execution example of registering LDEVs to the pool as device groups, creating resource groups in the device group unit and migrating created resource groups Provisioning operations with CCI

153 C:\HORCM\etc>raidcom add device_grp -device_grp_name dg_jnl1 data1 - ldev_id C:\HORCM\etc>raidcom get device_grp LDEV_GROUP Serial# dg_jnl C:\HORCM\etc>raidcom get device_grp -device_grp_name dg_jnl1 LDEV_GROUP LDEV_NAME LDEV# Serial# dg_jnl1 data dg_jnl1 data dg_jnl1 data dg_jnl1 data C:\HORCM\etc>raidcom add resource -resource_name rsg002 -grp_opt ldev - device_grp_name dg_jnl1 GROUP = dg_jnl1, DEVICE = data1, UnitID = 0, LDEV = 512(0x0200)[1], PORT = none, LUN = none :done GROUP = dg_jnl1, DEVICE = data1, UnitID = 0, LDEV = 513(0x0201)[1], PORT = none, LUN = none :done GROUP = dg_jnl1, DEVICE = data1, UnitID = 0, LDEV = 514(0x0202)[1], PORT = none, LUN = none :done GROUP = dg_jnl1, DEVICE = data1, UnitID = 0, LDEV = 515(0x0203)[1], PORT = none, LUN = none :done C:\HORCM\etc>raidcom delete resource -resource_name rsg002 -grp_opt ldev -device_grp_name dg_jnl1 GROUP = dg_jnl1, DEVICE = data1, UnitID = 0, LDEV = 512(0x0200)[1], PORT = none, LUN = none :done GROUP = dg_jnl1, DEVICE = data1, UnitID = 0, LDEV = 513(0x0201)[1], PORT = none, LUN = none :done GROUP = dg_jnl1, DEVICE = data1, UnitID = 0, LDEV = 514(0x0202)[1], PORT = none, LUN = none :done GROUP = dg_jnl1, DEVICE = data1, UnitID = 0, LDEV = 515(0x0203)[1], PORT = none, LUN = none :done Internal volume operations Creating internal volumes (open-systems) To create LDEVs of internal open-systems volumes and make the LDEVs available to the host, perform the following provisioning operations. Step Operation Description Command 1 Setting port Enable LUN security of the port. Modify settings such as port topology and data transfer speed as needed. 2 Creating host group Specify port and create host group. raidcom modify port -port <port>-security_switch y raidcom add host_grp -port <port> -host_grp_name <host group name> Provisioning operations with CCI 5 19

154 Step Operation Description Command 3 Setting host mode 4 Displaying host group information 5 Adding host to host group 6 Displaying WWN information Specify port and set host mode for host group. Display host group information and confirm result of executing command. Register host to host group of the port. Display WWN of connection host registered to the host group and confirm the result of executing the command. 7 Creating LDEV Specify a parity group and create LDEV. 8 Formatting LDEV 9 Creating LDEV nickname (arbitrary) 10 Setting MP blade of LDEV 11 Displaying LDEV information 12 Creating LU path 13 Displaying LU path information Format created LDEV. Create nickname for created LDEV. This operation is arbitrary. Set MP blade of created LDEV. Display information of created LDEV and confirm the result of executing the command. Specify port, map LDEV to LUN and create an LU path. Display LU path information and confirm the result of executing the command. raidcom modify host_grp -port <port> [<host group name>] -host_mode < host mode> [-host_mode_opt <host mode option> ] raidcom get host_grp -port <port> [<host group name>] raidcom add hba_wwn -port <port> [<host group name>] -hba_wwn <WWN strings> raidcom get hba_wwn -port <port> [<host group name>] raidcom add ldev -parity_grp_id <gno-sgno> -ldev_id <ldev#> -capacity <size> [-emulation <emulation type>] [-location <lba>] [ mp_blade_id <mp#>] raidcom initialize ldev -ldev_id <ldev#> -operation <type> raidcom modify ldev -ldev_id <ldev#> -ldev_name <ldev naming> raidcom modify ldev -ldev_id <ldev#> -mp_blade_id <mp#> raidcom get ldev -ldev_id <ldev#> [-cnt <count>] [-key <keyword>] raidcom add lun -port <port> [<host group name>] -ldev_id <ldev#> [-lun_id<lun#>] raidcom get lun -port <port> [<host group name>] Creating internal volumes (Mainframe volume) To create LDEVs of internal volumes (Mainframe volume) and make the LDEVs available to the host, perform the following provisioning operations Provisioning operations with CCI

155 Step Operation Description Command 1 SSID settings (arbitrarily) Configures the SSID unless it is configured. Set (register) the SSID by specifying undefined LDEV numbers in the area in which SSIDs are not defined. 2 Creating LDEVs Creates LDEVs by specifying parity groups. 3 Formatting LDEVs 4 Creating LDEV nicknames (arbitrarily) 5 Configuring MP blades of LDEVs 6 Displaying a LDEV information Formats created LDEVs. Creates LDEV nicknames. This operation is optional. Configures MP blades of created LDEVs. Displays an information of created LDEV, and confirms an execution result of the command. raidcom modify ldev -ldev_id <ldev#> -ssid<value> raidcom add ldev -parity_grp_id <gno-sgno> -ldev_id <ldev#> {-capacity <size> -offset_capacity <size> -cylinder <size>} [-emulation <emulation type>][-location <lba>][-mp_blade_id <mp#>] raidcom initialize ldev -ldev_id <ldev#> -operation <type> raidcom modify ldev -ldev_id <ldev#> -ldev_name <ldev naming> raidcom modify ldev -ldev_id <ldev#> -mp_blade_id <mp#> raidcom get ldev -ldev_id <ldev#> [-cnt <count>] [-key <keyword>] Script examples The following shows the script examples of internal volume (mainframe volume) operations. Provisioning operations with CCI 5 21

156 Figure 5-2 Script examples of internal volume (Mainframe volume) operation 5 22 Provisioning operations with CCI

157 Script examples The following shows script examples for internal open-system volume operations. Figure 5-3 Script examples of internal open-system volume operation (1/2) Provisioning operations with CCI 5 23

158 Figure 5-4 Script examples of internal open-system volume operation (2/2) Virtual volume (Dynamic Provisioning) operations Creating virtual volumes (Dynamic Provisioning) Use the following provisioning operations to create LDEVs of virtual volumes (Dynamic Provisioning) and make the LDEVs available to the host. Step Operation overview Description Executed command 1 Setting port Enable LUN security for the port. Modify settings such as port topology and data transfer speed as needed. 2 Creating host group Specify port and create host group. raidcom modify port -port <port>-security_switch y raidcom add host_grp -port <port> -host_grp_name <host group name> 5 24 Provisioning operations with CCI

159 Step Operation overview Description Executed command 3 Setting host mode 4 Displaying host group information 5 Adding host to host group 6 Displaying WWN information Specify port and set host mode for host group. Display host group information and confirm result of executing command. Register host to host group of the port. Display WWN of connection host registered to the host group and confirm the result of executing the command. 7 Creating LDEV Specify a parity group and create LDEV. 8 Formatting LDEV 9 Creating LDEV nickname (arbitrary) 10 Setting MP blade of LDEV 11 Displaying LDEV information 12 Creating pool (for Dynamic Provisioning) Format created LDEV. Create nickname for LDEV. This operation is arbitrary. Set MP blade of created LDEV. Display information of created LDEV and confirm the result of executing the command. Create pool (for Dynamic Provisioning). raidcom modify host_grp -port <port> [<host group name>] -host_mode <host mode> [-host_mode_opt <host mode option> ] raidcom get host_grp -port <port> [<host group name>] raidcom add hba_wwn -port <port> [<host group name>] -hba_wwn <WWN strings> raidcom get hba_wwn -port <port> [<host group name>] raidcom add ldev -parity_grp_id <gno-sgno> -ldev_id <ldev#> {-capacity <size> -offset_capacity <size> -cylinder <size>} [-emulation <emulation type>][-location <lba>] [-mp_blade_id <mp#>] raidcom initialize ldev -ldev_id <ldev#> -operation <type> raidcom modify ldev -ldev_id <ldev#> -ldev_name <ldev naming> raidcom modify ldev -ldev_id <ldev#> -mp_blade_id <mp#> raidcom get ldev -ldev_id <ldev#> [-cnt <count>] [-key <keyword>] raidcom add dp_pool {{-pool_id <pool ID#> [-pool_name <pool naming>] -pool_name <pool naming>[-pool_id <pool ID#>]} -pool_id <pool ID#> -pool_name <pool naming>}} -ldev_id <ldev#> [-cnt <count>] [-user_threshold <threshold_1> [<threshold_2>]] Provisioning operations with CCI 5 25

160 Step Operation overview Description Executed command Script examples 13 Creating LDEV (V-VOL) 14 Creating LDEV (V-VOL) nickname (arbitrary) 15 Setting MP blade of LDEV (V-VOL) 16 Displaying LDEV information (V-VOL) 17 Creating LU path 18 Displaying LU path information Specify pool and create an LDEV(V-VOL). Create nickname for the created LDEV. This operation is arbitrary. Set MP blade of created LDEV (V-VOL). Display information of created LDEV (V-VOL) and confirm the result of executing the command. Specify port, map LDEV to LUN and create an LU path. Display LU path information and confirm the result of executing the command. raidcom add ldev -pool {<pool ID#> <pool naming> snap} -ldev_id <ldev#> {-capacity <size> -offset_capacity <size> -cylinder <size>} [-emulation <emulation type>][-location <lba>] [-mp_blade_id <mp#>] raidcom modify ldev -ldev_id <ldev#> -ldev_name <ldev naming> raidcom modify ldev -ldev_id <ldev#> -mp_blade_id <mp#> raidcom get ldev -ldev_id <ldev#> [-cnt <count>] [-key <keyword>] raidcom add lun -port <port> [host group name] -ldev_id <ldev#> [-lun_id <lun#>] raidcom get lun -port <port> [<host group name>] The following shows script examples of virtual volume (Dynamic Provisioning) operation Provisioning operations with CCI

161 Figure 5-5 Script examples of virtual volume operation (Dynamic Provisioning) (1/3) Provisioning operations with CCI 5 27

162 Figure 5-6 Script examples of virtual volume operation (Dynamic Provisioning) (2/3) 5 28 Provisioning operations with CCI

163 Figure 5-7 Script examples of virtual volume operation (Dynamic Provisioning) (3/3) Virtual volume (Dynamic Provisioning for Mainframe) operations Creating virtual volumes (Dynamic Provisioning for Mainframe) To create LDEVs of virtual volumes (Dynamic Provisioning for Mainframe) and make the LDEVs available to the host, perform the following Provisioning operations. Step Operation overview Description Executed command 1 SSID settings (arbitrarily) 2 Creating LDEVs 3 Formatting LDEVs 4 Creating LDEV nicknames (arbitrarily) Configures the SSID unless it is configured. Set (register) the SSID by specifying undefined LDEV numbers in the area in which SSIDs are not defined. Creates LDEVs by specifying parity groups. Specifies only 3390-V for the emulation type. Formats created LDEVs. Creates LDEV nicknames. This operation is optional. raidcom modify ldev -ldev_id<ldev#> -ssid<value> raidcom add ldev -parity_grp_id <gno-sgno> -ldev_id <ldev#> {-capacity <size> -offset_capacity <size> -cylinder <size>} -emulation 3390-V -location <lba>] [-mp_blade_id <mp#>] raidcom initialize ldev -ldev_id <ldev#> -operation <type> raidcom modify ldev -ldev_id <ldev#> -ldev_name <ldev naming> Provisioning operations with CCI 5 29

164 Step Operation overview Description Executed command 5 Configuring MP blades of LDEVs 6 Displaying a LDEV information 7 Creating the pool (for the Hitachi Dynamic Provisioning for mainframe) 8 Creating LDEV (V-VOL) 9 Creating LDEV (V-VOL) nicknames (arbitrarily) 10 Configuring MP blades of LDEVs (V-VOL) 11 Displaying a LDEV (V-VOL) information Configures MP blades of created LDEVs. Displays an information of created LDEV, and confirms an execution result of the command. Creates the pool for the Hitachi Dynamic Provisioning for mainframe. Specifies the pool and creates LDEV (V-VOL). Creates LDEV (V-VOL) nicknames. This operation is optional. Configures MP blades of created LDEVs (V-VOL). Displays an information of created LDEV (V-VOL), and confirms an execution result of the command. raidcom modify ldev -ldev_id <ldev#> -mp_blade_id <mp#> raidcom get ldev -ldev_id <ldev#> [-cnt <count>] [-key <keyword>] raidcom add dp_pool {{-pool_id <pool ID#> [-pool_name <pool naming>] -pool_name <pool naming>[-pool_id <pool ID#>]} -pool_id <pool ID#> -pool_name <pool naming>} {-ldev_id <ldev#> [-cnt <count>] -grp_opt <group option> -device_grp_name <device group name> [<device name>]}[ -user_threshold <threshold_1> [<threshold_2>] ] raidcom add ldev -pool {<pool ID#> <pool naming> snap} -ldev_id <ldev#>{-capacity <size> -offset_capacity <size> -cylinder <size>} [-emulation <emulation type>][-location <lba>] [-mp_blade_id <mp#>] raidcom modify ldev -ldev_id <ldev#> -ldev_name <ldev naming> raidcom modify ldev -ldev_id <ldev#> -mp_blade_id <mp#> raidcom get ldev -ldev_id <ldev#> [-cnt <count>] [-key <keyword>] Script examples The following shows the script examples of virtual volume (Dynamic Provisioning for mainframe) operation Provisioning operations with CCI

165 Figure 5-8 Script examples of virtual volume operation (Dynamic Provisioning for Mainframe) (1/2) Provisioning operations with CCI 5 31

166 Virtual volume (Dynamic Tiering) operations Operational flow Figure 5-9 Script examples of virtual volume operation (Dynamic Provisioning for Mainframe) (2/2) When using the V-VOL (Dynamic Tiering), tiers of pools must be created after creating pools, and then the performance of pools must be monitored before the operation. If the performance of pools are insufficient, extend the capacity of pool volumes (addition of pool volumes) and of the V-VOL. The following diagram shows the flow of work to use a virtual volume (Dynamic Tiering) when operating with GUI (Storage Navigator) or CCI: 5 32 Provisioning operations with CCI

167 Provisioning operations with CCI 5 33

168 Note *1: The multiple tiering pool is disabled when a pool is creating at CCI. And multiple media cannot be registered as a pool volume when a pool is created. Execute tiering after changing the multiple tiering pool to the enabled status. Note *2: When the multiple tiering pool is enabled, the tiering control is set to "Manual" automatically. To change the setting to "Auto", it is required to execute from Storage Navigator. Note: Before creating a pool, it is required to create a virtual volume management area on the cache memory. The virtual volume management area is created automatically when add a cache memory. For the information about adding cache memory, please contact the Support Center. Caution: The operations are explained here are executable by the storage administrator only. Creating virtual volumes (Dynamic Tiering) Use the following operations to create LDEVs of virtual volumes (Dynamic Tiering) and making the LDEVs available to the host. Step Operation overview Description Executed command 1 Setting port Make enabled the LUN security of port. Modify setting such as port topology and data transfer speed as needed. 2 Creating host group 3 Setting host mode 4 Displaying host group information 5 Adding host to host group 6 Displaying WWN information Specify port and create host group. Specify port and set host mode for host group. Display host group information and confirm result of executing command. Register host to host group of the port. Display WWN of connection host registered to the host group and confirm the result of executing the command. raidcom modify port -port <port>-security_switch y raidcom add host_grp -port <port> -host_grp_name <host group name> raidcom modify host_grp -port <port> [<host group name>] -host_mode <host mode> [-host_mode_opt <host mode option> ] raidcom get host_grp -port <port> [<host group name>] raidcom add hba_wwn -port <port> [<host group name>] -hba_wwn <WWN strings> raidcom get hba_wwn {-port <port> [<host group name>]} 5 34 Provisioning operations with CCI

169 Step Operation overview Description Executed command 7 Creating LDEV Specify a parity group and create LDEV. 8 Formatting LDEV 9 Creating LDEV nickname (arbitrary) 10 Setting MP blade of LDEV 11 Displaying LDEV information 12 Creating pool (for Dynamic Provisioning) 13 Setting pool option 14 Adding different media to pool volume 15 Creating LDEV (V-VOL) Format created LDEV. Create LDEV nickname. This operation is arbitrary. Set MP blade of created LDEV. Display information of created LDEV and confirm the result of executing the command. Create pool (for Dynamic Provisioning). Modify pool for Dynamic Provisioning to pool for Dynamic Tiering. Add a pool volume of different media to a pool for Dynamic Tiering. Specify pool and create LDEV (V-VOL). raidcom add ldev {-parity_grp_id <gno-sgno> -ldev_id <ldev#> {-capacity <size> -offset_capacity <size> -cylinder <size>} [-emulation <emulation type>][-location <lba>] [-mp_blade_id <mp#>] raidcom initialize ldev -ldev_id <ldev#> -operation <type> raidcom modify ldev -ldev_id <ldev#> -ldev_name <ldev naming> raidcom modify ldev -ldev_id <ldev#> -mp_blade_id <mp#> raidcom get ldev -ldev_id <ldev#> [-cnt <count>] [-key <keyword>] raidcom add snap_pool {{-pool_id <pool ID#> [-pool_name <pool naming>] -pool_name <pool naming>[-pool_id <pool ID#>]} -pool_id <pool ID#> -pool_name <pool naming>}} -ldev_id <ldev#> [-cnt count>] [-user_threshold <%> ] raidcom modify pool -pool {<pool ID#> <pool naming>} -pool_attribute dt_manual raidcom add dp_pool {{-pool_id <pool ID#> [-pool_name <pool naming>] -pool_name <pool naming>[-pool_id <pool ID#>]} -pool_id <pool ID#> -pool_name <pool naming>} -ldev_id <ldev#> [-cnt <count>] [ -user_threshold <threshold_1> [<threshold_2>] ] raidcom add ldev -pool {<pool ID#> <pool naming> snap} -ldev_id <ldev#> -capacity <size> [-emulation <emulation type>][-location <lba>] [-mp_blade_id <mp#>] Provisioning operations with CCI 5 35

170 Step Operation overview Description Executed command 16 Creating LDEV (V-VOL) nickname (arbitrary) 17 Setting MP blade of LDEV (V-VOL) 18 Displaying LDEV (V-VOL) information 19 Creating LU path 20 Displaying LU path information 21 Starting performance monitoring of a pool for Dynamic Tiering. 22 Stopping performance monitoring of a pool for Dynamic Tiering. 23 Instructing reallocation of pool for Dynamic Tiering Create nickname for created LDEV (V-VOL). This operation is arbitrary. Set MP blade of created LDEV (V-VOL). Display information of created LDEV (V-VOL) and confirm the result of executing the command. Specify port, map LDEV to LUN and create an LU path. Display LU path information and confirm the result of executing the command. Start the performance monitoring of a pool for Dynamic Tiering. Stop the performance monitoring of a pool for Dynamic Tiering. Perform instruction of reallocation of pool for Dynamic Tiering. raidcom modify ldev -ldev_id <ldev#> -ldev_name <ldev naming> raidcom modify ldev -ldev_id <ldev#> -mp_blade_id <mp#> raidcom get ldev -ldev_id <ldev#> [-cnt <count>] [-key <keyword>] raidcom add lun -port <port> [host group name] -ldev_id <ldev#> [-lun_id <lun#>] raidcom get lun -port <port> [<host group name>] raidcom monitor pool -pool {<pool ID#> <pool naming>} -operation start raidcom monitor pool -pool {<pool ID#> <pool naming>} -operation stop raidcom reallocate pool -pool {<pool ID#> <pool naming>} -operation <type> Script examples The following shows the script examples of virtual volume (Dynamic Tiering) operation Provisioning operations with CCI

171 Figure 5-10 Script examples of virtual volume operation (Dynamic Tiering) (1/3) Provisioning operations with CCI 5 37

172 Figure 5-11 Script examples of virtual volume operation (Dynamic Tiering) (2/3) 5 38 Provisioning operations with CCI

173 Figure 5-12 Script examples of virtual volume operation (Dynamic Tiering) (3/3) External volume operations Creating external volumes Use the following provisioning operations to create LDEVs of external volumes and make the LDEVs available from the host. Provisioning operations with CCI 5 39

174 Step Operation overview Description Executed command 1 Setting port attribute of local storage system 2 Searching external storage 3 Searching external volume 4 Creating external volume 5 Modifying external volume option 6 Checking external volume information 7 Setting external path 8 Displaying external path information 9 Setting port of external storage system 10 Creating host group 11 Setting host mode 12 Displaying host group information Set port attribute of local storage system to External (ELUN)port Display port information on the external storage connected to the External port. Display a list of external volumes that can be mapped from External port. Create external volume. Modify external volume option (cache mode, inflow mode, and MP blade setting). Display external volume information and confirm result of executing command. Set external path. Execute the required number of commands. Display external path information for and confirm the result of executing the command. Make enabled the LUN security of port. Modify setting such as port topology and data transfer speed as needed. Specify port, map LDEV to LUN and create an LU path. Specify port and set host mode for host group. Display host group information and confirm result of executing command. raidcom modify port -port <port> -port_attribute ELUN raidcom discover external_storage -port <port> raidcom discover lun -port <port> -external_wwn <wwn strings> raidcom add ldev - external_grp_id <gno-sgno> -ldev_id <ldev#> -capacity <size> [-emulation <emulation type>][-location <lba>] [ mp_blade_id <mp#>] raidcom modify external_grp -external_grp_id <gno-sgno> {-cache_mode < y n > -cache_inflow < y n > -mp_blade_id <mp#>} raidcom get external_grp [-external_grp_id <gno-sgno>] raidcom add path -path_grp <path group#> -port <port> -external_wwn <wwn strings> raidcom get path [-path_grp <path group#>] raidcom modify port -port <port> -security_switch y raidcom add host_grp -port <port> -host_grp_name <host group name> raidcom modify host_grp -port <port> [<host group name>] -host_mode <host mode> [-host_mode_opt <host mode option> ] raidcom get host_grp -port <port> [<host group name>] 5 40 Provisioning operations with CCI

175 Step Operation overview Description Executed command 13 Adding host to host group 14 Displaying WWN information Register host to host group of the port. Display WWN of connection host registered to the host group and confirm the result of executing the command. 15 Creating LDEV Specify external volume group and create LDEV. 16 Creating LDEV nickname (arbitrary) 17 Setting MP blade of LDEV 18 Displaying LDEV information 19 Creating LU path 20 Displaying LU path information Create nickname of created LDEV. This operation is arbitrary. Set MP blade of created LDEV. Display information of created LDEV and confirm the result of executing the command. Specify port, map LDEV to LUN and create an LU path. Display LU path information and confirm the result of executing the command. raidcom add hba_wwn -port <port> [<host group name>] -hba_wwn <WWN strings> raidcom get hba_wwn -port <port> [<host group name>] raidcom add ldev - external_grp_id <gno-sgno> -ldev_id <ldev#> {-capacity <size> -offset_capacity <size> -cylinder <size>} [-emulation <emulation type>][-location <lba>] [-mp_blade_id <mp#>] raidcom modify ldev -ldev_id <ldev#> -ldev_name <ldev naming> raidcom modify ldev -ldev_id <ldev#> -mp_blade_id <mp#> raidcom get ldev -ldev_id <ldev#> [-cnt <count>] [-key <keyword>] raidcom add lun -port <port> [<host group name>] -ldev_id <ldev#> [-lun_id<lun#>] raidcom get lun -port <port> [<host group name>] Script Examples The following shows the script examples of external volume operations. Provisioning operations with CCI 5 41

176 Figure 5-13 Script Examples of External Volume Operation (1/3) 5 42 Provisioning operations with CCI

177 Figure 5-14 Script Examples of External Volume Operation (2/3) Provisioning operations with CCI 5 43

178 Figure 5-15 Script Examples of External Volume Operation (3/3) Virtual Partition Manager operations Virtual Partition Manager operations using CCI include migrating LDEVs, parity groups, and external volume groups to other CLPRs. For information about Virtual Partition Manager operations, including important warnings and restrictions, see the Hitachi Virtual Partition Manager User Guide for USP V/VM or the Performance Guide for VSP. For details about the CCI commands for Virtual Partition Manager operations, see the Command Control Interface Command Reference. Performing Virtual Partition Manager operations The following table shows the procedure for migrating LDEVs, parity groups, and external volume groups to other CLPRs. Step Operation overview Description Command 1 Confirming the CLPR configuration. Check the status of the CLPRs. raidcom get clpr 5 44 Provisioning operations with CCI

179 Step Operation overview Description Command 2 Migrating one of the following to other CLPRs: LDEV parity group external volume group 3 Verifying the CLPR migration. Displaying CLPR information Specify the LDEV number, parity group number, or external volume group number. For parity group migration, check the status of the parity group. raidcom modify clpr -clpr <clpr#> { -ldev_id <ldev#> -parity_grp_id <gno-sgno> - external_grp_id <gnosgno>} raidcom get parity_grp The raidcom get clpr command lists and displays the status of the CLPRs in the storage system. If no CLPRs have been created, CLPR0 is displayed as entire cache. Display example: # raidcom get clpr CLPR CLPR_NAME TC_CAP(MB) TU_CAP(MB) WP_CAP(MB) SF_CAP(MB) U(%) W(%)S(%) 000 Oracle_DB Oracle_DB_PROD Oracle_DB_BACK Migrating parity groups in a CLPR This section explains operations from checking the parity group information to moving the parity group. Displaying parity group information The raidcom check the status, display the information about the parity group. The following shows the display example of parity groups. # raidcom get parity_grp T GROUP Num_LDEV U(%) AV_CAP(GB) R_LVL R_TYPE SL CL DRIVE_TYPE R RAID1 2D+2D 0 0 DKS2C-K072FC R RAID1 2D+2D 0 0 DKS2C-K072FC R RAID1 2D+2D 0 0 DKS2C-K072FC R RAID1 2D+2D 0 3 DKS2C-K072FC Moving parity groups If you change the allocation of parity groups, parity groups are moved from another CLPR. In this case, plural parity groups which configure the distributed parity group have to be allocated the same CLPR. Parity groups including LDEVs where cache area of Cache Residency is defined cannot be Provisioning operations with CCI 5 45

180 moved to another CLPR. For the restrictions on the CLPR's transfer, see the Performance Guide. The following shows examples of parity groups transfer in CLPR. Move the parity group to the CLPR number 1. # raidcom modify clpr clpr 1 parity_grp_id Checking result of CLPR transfer By displaying the information about parity groups, check the result of CLPR transfer. The following shows an example of parity group list. # raidcom get parity_grp T GROUP Num_LDEV U(%) AV_CAP(GB) R_LVL R_TYPE SL CL DRIVE_TYPE R RAID1 2D+2D 0 0 DKS2C-K072FC R RAID1 2D+2D 0 1 DKS2C-K072FC R RAID1 2D+2D 0 3 DKS2C-K072FC R RAID1 2D+2D 0 3 DKS2C-K072FC Server Priority Manager operations Server Priority Manager enables you to prioritize host I/O operations to provide high-speed processing for specified hosts. The host is identified by WWN of host bus adapter. Server Priority Manager has two settings: prioritized and non-prioritized. Set the prioritized option for hosts that require high-speed processing, and the non-prioritized option for the other hosts. The upper limit of the non-prioritized WWN is set to each port to which the non-prioritized WWN belongs and is applied only to the port. If the threshold is set to the port to which the prioritized WWN belongs, the threshold overwrites the thresholds of all the ports in the storage system to which the prioritized WWN belongs as well. For more details about the upper limit and the threshold, see Setting the priority on host bus adapter on page For details about the CCI commands for Server Priority Manager operations, see the Command Control Interface Command Reference. You can give a nickname (SPM name) to each host WWN to assist in managing the hosts. You can also manage WWN and the SPM name per group. The groups to which WWN and the SPM name are registered are managed uniquely. The following table lists the details for the Server Priority Manager operations and the management unit. SPM Operation Management per port Management per system raidcom modify spm_wwn prioritized or non-prioritized threshold upper limit WWN or SPM name raidcom modify spm_group prioritized or non-prioritized threshold upper limit SPM group name raidcom add spm_wwn - SPM name 5 46 Provisioning operations with CCI

181 SPM Operation Management per port Management per system raidcom add spm_group - SPM group name raidcom delete spm_wwn - SPM name (SPM information per port is also deleted.) raidcom delete spm_group - SPM group name (SPM information per port is also deleted.) raidcom get spm_wwn prioritized or non-prioritized upper limit WWN or SPM name SPM group name threshold raidcom get spm_group raidcom monitor spm_wwn raidcom monitor spm_group prioritized or non-prioritized upper limit SPM group name performance of server (IOps/ KBps) performance of server (IOps/ KBps) State transitions of Server Priority Manager threshold control mode of SPM control mode of SPM The following shows the state by the SPM operation and its state transition. Controlling server performance The server performance is controlled by setting the priority of the I/O operation, the upper limit, and a threshold (per system) for the host bus adapter. The following table shows the procedure for controlling the server performance by setting the priority of the I/O operation, the upper limit, and a threshold (per system) for the host bus adapter. Provisioning operations with CCI 5 47

182 Step Operation overview Description Executed command 1 Setting the SPM information for WWN 2 Giving a nickname (SPM name). 3 Registering WWN for SPM to SPM group 4 Checking the SPM information Set the priority (prioritized or nonprioritized option) for the SPM controlling by specifying the number of port to which the host bus adapter is connected and WWN of the host bus adapter. Give a nickname to WWN for the SPM controlling to make the host bus adapter distinguishable. Specifying WWN: To operate per group, group multiple WWNs for SPM control into one group. Specifying nickname: To operate per group, group multiple WWNs for SPM control into one group. Display the setting state of SPM by specifying WWN or the SPM name. raidcom modify spm_wwn -port <port#> [-spm_priority <y/n>] {-limit_io -limit_kb -limit_mb } <value> {-hba_wwn <wwn_strings> -spm_name <nick_name>} raidcom add spm_wwn -port <port#> -spm_name <nick_name> -hba_wwn <wwn_strings> raidcom add spm_group -port <port#> -spm_group <group_name> -hba_wwn <wwn_strings> raidcom add spm_group -port <port#> -spm_group <group_name> <nick_name> raidcom get spm_wwn -port <port#> [ -hba_wwn <wwn_strings> -spm_name <nick_name> ] 5 Displaying the monitoring information of the prioritized WWN or the nonprioritized WWN 6 Changing the threshold or the upper limit value of the nonprioritized WWN Display the SPM information by specifying the SPM group name. Display the monitoring information by specifying WWN or the SPM name. Display the monitoring information by specifying the SPM group name. Change the threshold or the upper limit value of the non-prioritized WWN by specifying WWN or the SPM name. Change the threshold or the upper limit value of the non-prioritized WWN by specifying the SPM group name. raidcom get spm_group -port <port#> -spm_group <group_name> raidcom monitor spm_wwn {-hba_wwn <wwn_strings> -spm_name <nick_name>} raidcom monitor spm_group -spm_group <group_name> raidcom modify spm_wwn -port <port#> [-spm_priority <y/n>] {-limit_io -limit_kb -limit_mb } <value> {-hba_wwn <wwn_strings> -spm_name <nick_name>} raidcom modify spm_group -port <port> [-spm_priority <y/n>] {-limit_io -limit_kb -limit_mb } <value> -spm_group <group_name> 5 48 Provisioning operations with CCI

183 Step Operation overview Description Executed command 7 Deleting WWN from the SPM targets Delete WWN from the SPM targets by specifying WWN or the SPM name. Delete WWN from the SPM targets by specifying the SPM group name. raidcom delete spm_wwn -port <port#> [-hba_wwn <wwn_strings> -spm_name <nick_name> ] raidcom delete spm_group -port <port#> -spm_group <group_name> Checking WWN of host bus adapters Displays the WWN of the host bus adapters that are registered in host groups. Display example: # raidcom get hba_wwn -port CL4-E-0 PORT GID GROUP_NAME HWWN Serial# NICK_NAME CL4-E 0 Linux_x e08b0256f ORA_NODE0_CTL_0 CL4-E 0 Linux_x e08b039c ORA_NODE1_CTL_1 Setting the priority on host bus adapter Set the high-priority host bus adapter for the prioritized WWN, and set the low-priority host bus adapter for the non-prioritized WWN. You need to set the upper limit and the threshold with the priority. The upper limit is set for the non-prioritized WWN. In the low-priority server, the frequency of the access to the storage system or the data traffic is restricted with the upper limit. The threshold is set for the prioritized WWN. Only one threshold can be set for the entire storage system. The threshold cannot be set for each prioritized WWN. When the traffic of the high-priority server declines to the threshold, the control with the upper limit becomes invalid automatically. By adjusting the upper limit or the threshold to the appropriate value, the frequency of the access to the storage system or the data traffic becomes stabilized in a high level in the high-priority server. The following shows examples of the priority settings. Set the host bus adapter (WWN: e0,8b0256f8) to the nonprioritized WWN, and set 5000 [IOPS] as the upper limit. # raidcom modify spm_wwn -port CL4-E -spm_priority n -limit_io hba_wwn e0,8b0256f8 Set the host bus adapter (WWN: e0,8b039c15) to the prioritized WWN, and set 3000 [IOPS] as the threshold. # raidcom modify spm_wwn -port CL4-E -spm_priority y limit_io hba_wwn e0,8b039c15 -limit_io 3000 shown in the example of the priority setting is the threshold value of the entire system. Provisioning operations with CCI 5 49

184 Checking the status of the prioritized WWN and the non-prioritized WWN settings Display the status of the prioritized WWN and the non-prioritized WWN settings and check it. Display examples of the status of the prioritized WWN and the non-prioritized WWN settings. Display the status of settings of the prioritized WWN and the non-prioritized WWN assigned under the specified port (CL4-E). # raidcom get spm_wwn -port CL4-E PORT SPM_MD SPM_WWN NICK_NAME GRP_NAME Serial# CL4-E WWN e08b0256f CL4-E WWN e08b039c Display the status of setting to specify the WWN (210000e08b0256f8). # raidcom get spm_wwn -port CL4-E -hba_wwn e0,8b0256f8 PORT SPM_MD PRI IOps KBps Serial# CL4-E WWN N Displays the status of setting to specify the WWN (210000e08b039c15). # raidcom get spm_wwn -port CL4-E -hba_wwn e0,8b039c15 PORT SPM_MD FRI IOps KBps Serial# CL4-E WWN Y The threshold value displayed for the prioritized WWN by using the get spm_wwn command is set for the entire system. Setting SPM name for host bus adapter The host bus adapters can be identified by checking the WWNs, but using SPM names may make it easier to identify the host bus adapters. Display examples of setting the SPM name of the host bus adapter: Set the SPM name (ORA_NODE0_CTL_0) for the WWN (210000e08b0256f8). # raidcom add spm_wwn -port CL4-E -spm_name ORA_NODE0_CTL_0 -hba_wwn e0,8b0256f8 Set the SPM name (ORA_NODE1_CTL_1) for the WWN (210000e08b039c15). # raidcom add spm_wwn -port CL4-E -spm_name ORA_NODE1_CTL_1 -hba_wwn e0,8b039c15 SPM names are managed uniquely in the entire system. Grouping multiple host bus adapters into one group You can group the host bus adapters into SPM groups, and then use the SPM groups to change the priorities of multiple host bus adapters at the same time. You can also set the same upper limit value for all host bus adapters in a SPM group at the same time. Examples of setting the SPM group: Set the SPM name (ORA_NODE0_CTL_0) for the SPM gropup name (WWN_GRP_LINUX0) Provisioning operations with CCI

185 # raidcom add spm_group -port CL4-E -spm_group WWN_GRP_LINUX0 ORA_NODE0_CTL_0 Set the WWN (210000e08b039c15) for the SPM gropup name (WWN_GRP_LINUX1). # raidcom add spm_group -port CL4-E -spm_group WWN_GRP_LINUX1 -hba_wwn e0,8b039c15 SPM group names are managed uniquely in the entire system. Checking the traffic of the prioritized WWN and the non-prioritized WWN You can use the monitoring function to check whether the performance of the prioritized WWN can be secured by setting the upper limit. Example of acquiring the monitoring information: Acquires the monitoring information by specifying the WWN (210000e08b039c15). # raidcom monitor spm_wwn -hba_wwn e0,8b039c15 PORT SPM_MD IOps KBps Serial# CL4-E WWN Stopping performance control of server by using SPM function To stop controlling the performance of the server by using the SPM function, delete the SPM name from the SPM targets. Example of deleting from the SPM targets: Delete the SPM name ("ORA_NODE0_CTL_0") from the SPM targets. # raidcom delete spm_wwn -port CL4-E -spm_name ORA_NODE0_CTL_0 Caution about exclusive access control with Storage Navigator Server Priority Manager settings are exclusive for CCI operations and Storage Navigator operations: If you set Server Priority Manager using CCI, you cannot set Server Priority Manager from Storage Navigator. You need to delete all Server Priority Manager settings made using CCI, and then use Server Priority Manager on Storage Navigator to make the Server Priority Manager settings. If you set Server Priority Manager using Storage Navigator, you cannot set Server Priority Manager using CCI. You need to delete all Server Priority Manager settings made using Storage Navigator, and then use Server Priority Manager from CCI to make the Server Priority Manager settings. Deleting WWN from the SPM targets with SPM name or SPM group name If you delete WWN from the SPM targets by using the SPM name, the SPM setting and SPM name under the specified port are deleted. If the same SPM name is set to another port, only the SPM setting of the specified port is deleted. Provisioning operations with CCI 5 51

186 If you delete WWN from the SPM targets by using the SPM group name, the SPM setting and the group under the specified port are deleted. If the same SPM group name is set to another port, only the SPM setting of the specified port is deleted. Resource group function and restrictions when running Server Priority Manager When you use the resource group function, the range of operation is limited per port of resource group by Server Priority Manager. The threshold value, the SPM name, and the SPM group name, which are managed in the entire system, are common among the resource groups. When you perform Server Priority Manager operations using the resource group function, share the threshold value that the storage administrator determines among users of resource groups. Determine rules for SPM names and SPM group names including port names to avoid redundant names between ports. Virtual storage machine operations (VSP G1000 only) Creating host groups in a virtual storage machine on page 5-52 Adding LDEVs to a virtual storage machine on page 5-53 Removing the virtual storage machine on page 5-53 Creating host groups in a virtual storage machine Use the following provisioning operations to create host groups in a virtual storage machine and to assign virtualized LDEV to LU. Ste p Operation overview Description Executed command 1 Reserving host group IDs 2 Creating host groups 3 Specifying the host mode and host mode options 4 Adding hosts to the host group Reserve ports and host group IDs to the resource groups in the virtual storage machine. Be sure to execute the command before creating host groups. Create host groups by specifying the reserved port and host group ID to the resource group. Specify the host mode to the created host group. Also, specify the host mode options if necessary. Register hosts to the host group. raidcom add resource -resource_name <resource group name> -port <port#>-<hg#> raidcom add host_grp -port <port>-<hg#> -host_grp_name <host group name> raidcom modify host_grp -port <port> [<host group name>] - host_mode < host mode> [- host_mode_opt <host mode option> ] raidcom add hba_wwn -port <port> [<host group name>] -hba_wwn <WWN strings> 5 52 Provisioning operations with CCI

187 Adding LDEVs to a virtual storage machine Use the following provisioning operations to add LDEVs to a virtual storage machine and to use LDEVs from hosts. Ste p Operation overview Description Executed command 1 Delete the virtual LDEV ID set by default 2 Add the LDEV to the resource group Specify an LDEV ID to delete the virtual LDEV ID set by default. By default, the virtual LDEV ID is the same as the real LDEV ID. Add the LDEV of which the virtual LDEV ID was deleted to the resource group in the virtual storage machine. 3 Virtualize LDEVs Set a virtual LDEV ID to the specified LDEV. Also, specify the product ID and SSID if necessary. 4 Create LU path To create LU path, assign LDEVs to the host group that belongs to the resource group in the virtual storage machine. Removing the virtual storage machine raidcom unmap resource -ldev_id <ldev#> -virtual_ldev_id <ldev#> raidcom add resource -resource_name <resource group name> -ldev_id <ldev#> raidcom map resource -ldev_id <ldev#> - virtual_ldev_id <ldev#> [-ssid<ssid> -emulation <emulation type>] raidcom add lun -port <port> [<host group name>] -ldev_id <ldev#> [-lun_id<lun#>] Use the following provisioning operations to remove resources from the virtual storage machine and to remove the virtual storage machine. Ste p Operation overview Description Executed command 1 Remove the LU path 2 Remove the virtual LDEV ID 3 Remove the LDEV from the resource group 4 Invalidate the LDEV virtualization Remove the LU path from the LDEV in the virtual storage machine. Remove the virtual LDEV ID from the LDEV in the virtual storage machine. Remove the LDEV from the resource group in the virtual storage machine Specify the virtual LDEV ID that is the same as the real LDEV ID in order to invalidate the LDEV virtualization. raidcom delete lun -port <port#> [<host group name>] {-lun_id <lun#> -ldev_id <ldev#> -grp_opt <group option> -device_grp_name <device group name> [<device name>]} raidcom unmap resource -ldev_id <ldev#> -virtual_ldev_id <ldev#> raidcom delete resource -resource_name <resource group name> -ldev_id <ldev#> raidcom map resource -ldev_id <ldev#> -virtual_ldev_id <ldev#> Provisioning operations with CCI 5 53

188 Ste p Operation overview Description Executed command 5 Delete the host group 6 Remove the host group ID from the resource group 7 Remove the resource from the resource group 8 Remove the virtual storage machine Delete the host group in the virtual storage machine. Remove the host group ID that belongs to the resource group in the virtual storage machine Remove the resource from the resource group in the virtual storage machine. Delete all resource groups in the virtual storage machine in order to remove the virtual storage machine. raidcom delete host_grp -port <port#> [<host group name>] raidcom delete resource -resource_name <resource group name> -port <port#> -<HG#> raidcom delete resource -resource_name <resource group name> [-ldev_id <ldev#> -port <port#> [<host group name>] -parity_grp <gno-sgno> -external_grp_id <gnosgno> -grp_opt <group option> -device_grp_name <device group name> [<device name>]] raidcom delete resource -resource_name <resource group name> 5 54 Provisioning operations with CCI

189 6 Data replication operations with CCI This chapter describes data replication operations with CCI. About data replication operations Features of paired volumes Using CCI with ShadowImage and TrueCopy Using CCI with Thin Image Using CCI with global-active device ShadowImage operations TrueCopy operations TrueCopy, ShadowImage, and Universal Replicator operations Copy-on-Write Snapshot operations Controlling Volume Migration Universal Replicator MxN configuration and control Remote volume discovery Data replication operations with CCI 6 1

190 About data replication operations The data replication features of the RAID storage systems include: Local replication: ShadowImage ShadowImage for Mainframe Thin Image Copy-on-Write Snapshot Remote replication: TrueCopy TrueCopy for Mainframe Universal Replicator Universal Replicator for Mainframe global-active device Mainframe replication: Compatible XRC Compatible FlashCopy V2 Business Continuity Manager For detailed information about any of these features, see the applicable user guide (for example, Hitachi ShadowImage User Guide). Features of paired volumes Paired logical volumes are often handled independently by servers. When CCI is used, the paired volumes can be managed by the replication functions (for example, TrueCopy, ShadowImage, Universal Replicator) as combined or separated pairs. The replication function regards the two volumes being combined or separated as a uniquely paired logical volume used by the servers. Paired volumes can also be handled as groups, grouping them by units of server software or units of databases and their attributes. For detailed information about volume pairs (for example, maximum number of pairs per storage system, maximum P-VOL size), see the user guide for your storage system and copy function (for example, Hitachi ShadowImage User Guide). 6 2 Data replication operations with CCI

191 Figure 6-1 Concept of paired volumes Addressing paired logical volumes: The correspondence of paired logical volumes to their physical volumes is defined by describing the paired logical volume names and group names in the configuration definition files of each server. It is possible to define a server for the paired logical volumes in units of group name. Each paired logical volume must belong to a group in order to determine the corresponding server. Specification of volumes by commands: Volume names to be used by the CCI commands must be referenced via the paired logical volume names or the group names. Using CCI with ShadowImage and TrueCopy CCI allows you to perform ShadowImage and TrueCopy operations by issuing ShadowImage and TrueCopy commands from the UNIX/PC server host to the RAID storage system. ShadowImage and TrueCopy operations are nondisruptive and allow the primary volume of each volume pair to Data replication operations with CCI 6 3

192 remain online to all hosts for both read and write operations. Once established, ShadowImage and TrueCopy operations continue unattended to provide continuous data backup. There are specific requirements for using ShadowImage and TrueCopy in high-availability (HA) configurations. UNIX/PC servers in HA configurations normally support disk duplication functions to enhance disk reliability (for example, mirroring provided by the LVM or device driver, RAID5 or an equivalent function provided by the LVM). UNIX/PC servers also feature hot standby and mutual hot standby functions in case of failures on the server side. However, mutual hot standby for disaster recovery has not yet been achieved since it requires the remote mirroring function. ShadowImage provides the mirroring function within the storage system. For detailed information about ShadowImage operations, please see the Hitachi ShadowImage User Guide for your storage system. TrueCopy provides remote mirroring functionality, linkage functionality with failover switching, and remote backup operations among servers, all of which are required by UNIX/PC servers in HA configurations for disaster recovery. For detailed information about TrueCopy operations, please see the Hitachi TrueCopy User Guide for your storage system. Using CCI with Thin Image CCI allows you to perform Hitachi Thin Image operations by issuing raidcom commands (for example, raidcom add snapshot) to the RAID storage system. Hitachi Thin Image stores snapshots in storage system. Creating a Thin Image pair changes the status to PAIR and stores snapshot data as a copy of the data on the Thin Image P-VOL. A Thin Image pair consists of a P-VOL, one or more S-VOLs that are virtual volumes (V-VOLs), and one or more pool-vols that are LDEVs. P-VOL differential data is stored as snapshot data in the pool-vols. If your storage system experiences a data storage failure, you can restore the data using the snapshot data in the pool. Splitting a Thin Image pair saves a snapshot and stops the copying of replaced data in the pool. Consistency groups and snapshot groups are groups of pairs for which you can simultaneously perform pair tasks on all pairs within the group. You can use CCI raidcom commands to create consistency groups and snapshot groups and to split pairs to store the snapshot data for the groups. A consistency group can include HTI, SI, and SIz pairs. Splitting the pairs using the group assures data consistency at the time the storage system receives the request. 6 4 Data replication operations with CCI

193 A snapshot group is a group of only Thin Image pairs. Use consistency or snapshot groups to perform Thin Image tasks on all of the pairs within the group. You define Thin Image pairs to a snapshot group when you create the pairs. Note: When you use the CCI to define multiple Thin Image pairs in a consistency group, you can only specify one consistency group for a group defined in the CCI configuration definition file. The configuration definition file for CCI is a group that is not a consistency group. Creating a new pair and defining the pairs in a consistency group for a group you defined using the CCI configuration definition file and the pair is already defined in a consistency group defines the pair in the same consistency group, even if you try to create a new pair and assign it to a different consistency group. For details about Hitachi Thin Image, see the Hitachi Thin Image User Guide for your storage system. Using CCI with global-active device The CCI software is installed on the host servers and used for global-active device operations. The CCI command devices and CCI configuration definition files are required for global-active device operations. You can execute CCI commands for global-active device using the in-band or out-ofband method of CCI command execution. For details about global-active device, see the Global-Active Device User Guide. For details about the CCI command options and display results for global-active device operations (for example, PHY_LDEV, VIR_LDEV), see the Command Control Interface Command Reference. Note: If you set the S-VOL Disable attribute of Data Retention Utility to a GAD secondary volume, GAD pair operations from CCI are restricted. Release the S-VOL Disable attribute of the GAD secondary volume, and then perform the GAD pair operations. ShadowImage operations Figure 6-2 ShadowImage system configuration on page 6-6 illustrates a ShadowImage configuration. The ShadowImage commands also support the functionality that links the system operation for the purpose of volume backup among UNIX servers managed by the operating system. For detailed information about the operational requirements and specifications for ShadowImage, see the Hitachi ShadowImage User Guide for your storage system. Following is a list of sample ShadowImage functions that can be executed using CCI commands: Pair creation: Creates a new volume pair. Volume pairs can be created in units of volumes or groups. Data replication operations with CCI 6 5

194 Pair splitting: Splits a volume pair and allows read and write access to the secondary volume. Pair resynchronization: Resynchronizes a split volume pair based on the primary volume. The primary volume remains accessible during resynchronization. Pair resynchronization with restore option: Resynchronizes a split pair based on the secondary volume (reverse resync). The primary volume is not accessible during resync with restore option. Event waiting: Used for waiting for the completion of a volume pair creation or resynchronization to check the pair status. Pair status display and configuration confirmation: Displays the pair status and configuration of the volume pairs; this can also be used for checking the completion of a pair creation or pair resynchronization. ShadowImage duplicated mirroring Figure 6-2 ShadowImage system configuration Duplicated mirroring of a single primary volume is possible when the ShadowImage feature is used. Duplicated mirror volumes can be specified up tp the maximum quantity 3. The duplicated mirror volumes of the P-VOL are expressed as virtual volumes using the mirror descriptors (MU#0-2) in the configuration diagram as shown below. 6 6 Data replication operations with CCI

195 ShadowImage cascading pairs Figure 6-3 ShadowImage duplicated mirrors ShadowImage provides a cascading function for the ShadowImage S-VOL. Cascading mirror volumes can be specified up to the maximum quantity 2. The cascading mirrors of the S-VOL are expressed as virtual volumes using the mirror descriptors (MU#1-2) in the configuration diagram as shown below. The MU#0 of a mirror descriptor is used for connection of the S-VOL. Data replication operations with CCI 6 7

196 Figure 6-4 ShadowImage cascade volume pairs Restrictions for ShadowImage cascading volumes Pair Creation. Pair creation of SVOL (oradb1) can only be performed after the pair creation of S/PVOL (oradb). If you create the oradb1 pair first without creating the oradb, the subsequent oradb creation will be rejected with EX_CMDRJE or EX_CMDIOE. 6 8 Data replication operations with CCI

197 Pair splitting. Pair splitting of SVOL (oradb1) can only be performed after the S/PVOL (oradb) is in a SMPL or PSUS state, since ShadowImage copies are asynchronous. If pair splitting of the SVOL (oradb1) is attempted while the S/PVOL (oradb) is in a COPY or PAIR state, the pairsplit command is rejected with EX_CMDRJE or EX_CMDIOE. Pair restore. Pair restore (resync from SVOL (oradb1) to S/PVOL) can only be performed when the SVOL (oradb) and the PVOL (oradb2) on the S/PVOL are in the SMPL and PSUS states. If the pair restore of SVOL (oradb1) is performed while either the SVOL (oradb) or PVOL (oradb2) on the S/PVOL are in a COPY, PAIR or PSUS state, the pairresync -restore command is rejected with EX_CMDRJE or EX_CMDIOE. Restriction for TrueCopy/ShadowImage cascading volumes Pair restore (resynchronization from SVOL (oradb1) to S/PVOL) can only be performed when the TrueCopy SVOL (oradb) and the PVOL (oradb2) on the S/PVOL are in the SMPL or PSUS(SSUS) state. If pairresync of S-VOL (oradb1) is performed when the S/PVOL (oradb or oradb2) is in any other state, the pairresync -restore option command is rejected with EX_CMDRJE or EX_CMDIOE. TrueCopy operations CCI TrueCopy commands operate in conjunction with the software on the UNIX/PC servers and the TrueCopy functions of the RAID storage systems. The CCI software provides failover and other functions such as backup Data replication operations with CCI 6 9

198 commands to allow mutual hot standby in cooperation with the failover product on the UNIX/PC server (for example, MC/ServiceGuard, FirstWatch, HACMP). Note: For proper maintenance of TrueCopy operations, it is important to determine if there are any faults in paired volumes, recover the volumes from the failures as soon as possible, and continue operation in the original system. Note: For information about the operational requirements and specifications for TrueCopy, please see the Hitachi TrueCopy User Guide for your storage system. TrueCopy takeover commands Figure 6-5 Server failover system configuration on page 6-10 illustrates a high-availability (HA) environment. When a server software error or a node error is detected, the HA failover software causes the cluster manager (CM) to monitor server programs and causes the CM of the standby node to automatically activate the HA control script of the corresponding server program. The HA control script usually contains database recovery procedures, server program activation procedures, and other related recovery procedures. The TrueCopy CCI takeover commands are also activated by the HA control script. Figure 6-5 Server failover system configuration Legend CM (Cluster Manager) : Demon process that keeps the consistency of the cluster by monitoring the node and server program in the cluster Data replication operations with CCI

199 Script : Shell script that automatically performs takeover process when CM detects the server failure. In an HA environment, a package is a group of applications that are scripted to run on the secondary host in the event of a primary host failure. When using the HA software (for example, MC/ServiceGuard), the package can be transferred to the standby node as an operation executed by the system administrator (see Figure 6-6 Package transfer on high availability (HA) software on page 6-11). Note: If the operation is performed when CCI and TrueCopy are being used, the volume is switched from primary to secondary as if an error had occurred, even though data consistency is assured. When restoral of the original node occurs along with its original package (group of applications), it is necessary to copy the data on the secondary volume onto the primary volume; this operation can take as much time as the initial copy operation for the pair. In actual operation, no package can be transferred when TrueCopy is being used. The secondary package is switched to the primary package, and vice versa, when the primary volume is switched to the secondary volume. Therefore, the primary and secondary TrueCopy volumes should be switched depending on the package state. Figure 6-6 Package transfer on high availability (HA) software The swap option of the takeover command allows swapping of the primary and secondary volume designations, so if the primary and secondary volume are switched due to a server error or package transfer, pair operation can be continued using the reversed volumes. When control is handed back over to the original node, swapping the volume designations again eliminates the need of copying them. In addition, the takeover command has the option to allow the secondary volume to be logically separated (for the purpose of recovery from a disaster at the original operating site). The takeover command has four functions designed for HA software operation: Takeoverswitch, swap-takeover, SVOL-takeover, and PVOL-takeover. This command is not available for ShadowImage Data replication operations with CCI 6 11

200 Takeover-switch function The control scripts activated by HA software are used by all nodes of a cluster in exactly the same manner so they have no discrimination between primary and secondary pair volumes (they just know the near and far disk in a pair). Thus, the takeover command, when activated by a control script, must check the combination of attributes of volumes possessed by the local and remote nodes and determine the proper takeover action. The table below shows the takeover actions. Table 6-1 Near/Local and Far/Remote Volume Attributes and Takeover Actions Local node (Takeover node) Volume attribute Fence and status Volume attribute Remote node P-VOL status Takeover action SMPL - SMPL - Reject P-VOL - Nop-takeover 1 P-VOL (primary) Fence == Data or && pair status == PSUE or PDUB or MINAP == 0 S-VOL - Unconformable Unknown - Reject SMPL - Reject P-VOL - Unconformable S-VOL - PVOL-Takeover 2 Unknown - PVOL-Takeover 2 Others SMPL - Reject P-VOL - Unconformable S-VOL - Nop-takeover 1 Unknown - Nop-takeover 1 S-VOL (secondar y) == SSWS (After SVOL_SSUStakeov er) - - Nop-takeover 1 Other than SSWS SMPL - Unconformable P-VOL PAIR or PFUL Swap-takeover 2 Notes: 1. No action needed to allow local writes. 2. Required to allow local writes. Others SVOL-takeover 2 S-VOL - Unconformable Unknown - SVOL-takeover 2 Nop-takeover: No operation is done to allow local writes, though the takeover command is accepted. Personality swaps must be accomplished in another way Data replication operations with CCI

201 Unconformable: A pair of volumes are not conformable to each other as a pair (that is, one P-VOL, one S-VOL). The takeover command execution terminates abnormally. Reject: The takeover command is rejected, and the operation terminates abnormally. Unknown: The attribute of the remote node is unknown and cannot be identified. This means that the remote node system has gone down or cannot communicate over the LAN. SSWS: Since the SSWS state is referring to a Suspend for Swapping with S-VOL Side only, the SSWS state is displayed as SSUS (SVOL_PSUS) by all commands except the -fc option of the pairdisplay command. Swap-takeover function The P-VOL status at the remote node is PAIR or PFUL (TrueCopy Async and over HWM) and the S-VOL has mirroring consistency. In such a state, it is possible to swap the primary and secondary volume designations to continue operation. The takeover command internally executes the operating commands (explained later) step by step, to swap the primary and secondary volume designations. Swapping can be specified at the granularity of volume pair, CT group, or volume group. The swap-takeover function does not use Simplex and No Copy mode for Swapping in order to guarantee mirror consistence more surely, and it is included as a function of SVOL-takeover. 1. As the preliminary step of swap-takeover, the command orders a Suspend for Swapping (SSWS) for the local volume (S-VOL). If this step fails, the swap-takeover function is disabled and it will be returned at an error. 2. The command orders a Resync for Swapping for switch to the primary volume that the local volume (S-VOL) is swapped as the NEW_PVOL and re-synchronizes the NEW_SVOL based on the NEW_PVOL. As for the number of simultaneous copy tracks, if the remote host is known then the command will use the value of P-VOL specified at paircreate time, else (remote host is Unknown) the command will use a default of 3 as the number of tracks for Resync for Swapping. If this step fails, the swap-takeover function will be returned at SVOLSSUS-takeover, and the local volume (S-VOL) is maintained in SSUS(PSUS) state which permits WRITE and maintaining delta data (BITMAP) for the secondary volume. Also this special state is displayed as SSWS state using -fc option of pairdisplay command. TrueCopy Async/Universal Replicator specific behavior for swaptakeover: The S-VOL side CCI will issue a Suspend for Swapping to the S- VOL side storage system. Non-transmitted data which remains in the FIFO queue (sidefile) of the primary volume will be copied to the S-VOL side and a Resync for Swapping operation will be performed (after the copy process). The Swap operation is required to copy Nontransmitted P-VOL data within a given timeout value (specified by the -t <timeout> option). Data replication operations with CCI 6 13

202 SVOL-takeover function The function makes it so the takeover node alone can use the secondary volume (except in COPY state) in SSUS(PSUS) state (i.e., reading and writing are enabled), on the assumption that the remote node (possessing the primary volume) cannot be used. The data consistency of the secondary volume is judged by its status and fence level. If this check proves that data is not consistent, the SVOLtakeover function fails. If this check proves that data is consistent then this function will try to switch the S-VOL to a primary volume using a Resync for Swapping, and if it succeeds then this function will return Swap-takeover, else this function will return SVOL-SSUS-takeover as the return value of horctakeover command. In case of a Host failure, this function will be returned as Swap-takeover. In case of a FICON or P-VOL site failure, this function will be returned as SVOL-SSUS-takeover. A SVOL-takeover can be specified by the granularity of a paired logical volume, CT group or volume group. If a SVOL-takeover is specified for a volume group, a data consistency check is executed for all volumes in the group. Inconsistent volumes are picked out and displayed in the execution log file as shown below: Example: Group Pair vol Port targ# lun# LDEV#...Volstat Fence To be... oradb1 ora001 CL1-A S-VOL PAIR NEVER Analyzed oradb1 ora002 CL1-A S-VOL PSUS STATUS Suspected Even so, the SVOL-takeover function enables the secondary volume to be used (i.e., reading and writing are enabled) since it assumes that the remote node (possessing the primary volume) cannot be used. TrueCopy Async/Universal Replicator specific behavior for svoltakeover: The S-VOL side CCI will issue a Suspend for Swapping to the S- VOL side storage system. Non-transmitted P-VOL data will be copied to the S-VOL and a Resync for Swapping operation will be performed (after the copy process). In case of a Host failure, this data synchronize operation will be accomplished and the SVOL-takeover function will return as Swaptakeover after attempting a Resync for Swapping. In case of a FICON or P-VOL site failure, this data synchronization operation may fail. Even so, the SVOL-takeover function will do Suspend for Swapping, and enable the secondary volume to be used Data replication operations with CCI

203 As a result, this function will return as SVOL-SSUS-takeover. Through this behavior, you will be able to judge that non-transmitted data of the primary volume was not transmitted completely when a SVOL-takeover returns SVOL-SSUS-takeover. PVOL-takeover function Caution: The SVOL-takeover operation is required to copy Nontransmitted P-VOL data within a given timeout value (specified by the -t <timeout> option). If the timeout occurs (before the SVOL-takeover operation has completed all S-VOL changes to a SSWS state), the horctakeover command will fail with EX_EWSTOT. If the horctakeover has failed due to a timeout then you need to try for a recovery as shown below. Wait until the S-VOL state becomes SSWS' via pairdisplay -g <group> -l -fc command, and try to the start-up again for the HA Control Script. Make an attempt to re-synchronize the original P-VOL based on the S- VOL using pairresync -g <group> -swaps -c <size> for a Fast Failback operation. If this operation fails with [EX_CMDRJE] or [EX_CMDIOE], this is due to a FICON link down or site failure. After a recovery from the failure, perform the operation again. Therefore this timeout value should be a greater than (or equal) to the start-up timeout value for the MC & CC Control Script. A PVOL-takeover relinquishes the pair state for a volume or group in order to make the P-VOL writable following some type of error (for example, link down with DATA fence). This function makes it so the takeover node alone can use the primary volume (that is, reading and writing are enabled), on the assumption that the remote node (possessing the secondary volume) cannot be used. The PVOL-takeover function has two functions: PVOL-PSUE-takeover, and PVOL-SMPL-takeover. A PVOL-PSUE-takeover forces the primary volume to suspend (PSUE, PSUS) state which permits WRITEs to all primary volumes of the group (even if the fence level is data). Therefore PSUE and/or PSUS are intermingled in the volume group through the action of this PVOLPSUE_ Takeover. This intermingled pair status creates PSUE as the group status, therefore the pairvolchk command results give precedence to PSUE (PDUB) status over PSUS for the group. This special state returns back to its original state by issuing the pairresync command. A PVOL-SMPL-Takeover forces the primary volume to simplex (SMPL) state so the pair is destroyed. At first, PVOL-takeover executes PVOL-PSUE-takeover. If PVOL-PSUE-takeover fails, it then executes PVOL- SMPLtakeover. PVOL-takeover can be specified per paired logical volume or per volume group. TrueCopy Async/Universal Replicator specific behavior for pvoltakeover: PVOL-Takeover will not be executed. It will become a Nop- Takeover, since the Fence Level will be Async which is equal to Never so it is not needed to allow P-VOL writes. Data replication operations with CCI 6 15

204 TrueCopy remote commands Figure 6-7 TrueCopy remote system configuration on page 6-17 illustrates a TrueCopy remote configuration. The CCI TrueCopy remote commands assist the system operation with volume backups among UNIX servers and their operating system management functions. The TrueCopy remote pair commands are also used to copy volumes in server failover configurations and to restore the volumes to their original state after a server failover has been recovered. Pair creation command: Creates a new volume pair. Volume pairs can be created in units of volume or group. Pair splitting command: Splits a volume pair and allows read and write access to the secondary volume. Pair resynchronization command: Resynchronizes a split volume pair based on the primary volume. The primary volume remains accessible during resynchronization. Swaps(p) option (TrueCopy only). Swaps volume from the SVOL(PVOL) to the PVOL(SVOL) when the SVOL(PVOL) is in the suspended state and resynchronizes the NEW_SVOL based on the NEW_PVOL. At the result of this operation, the volume attributes of the host of reference (local host) are used as the attributes for the NEW_PVOL(SVOL). Event waiting command: Used to wait for the completion of volume pair creation or resynchronization and to check the pair status. Pair status display and configuration confirmation command: Displays the pair status and configuration of the volume pairs and is used for checking the completion of pair creation or pair resynchronization Data replication operations with CCI

205 Legend HORCM : The manager is a demon process, executes multiple commands, charges to a storage system through itself. Among the managers are connected by UDP, remotely execute a command among the servers mutually. Command : A command provisioned by CCI. TrueCopy local commands Figure 6-7 TrueCopy remote system configuration Figure 6-8 TrueCopy local system configuration on page 6-18 illustrates a TrueCopy local configuration. The CCI TrueCopy local commands assist the system operation with volume backups among UNIX servers and their operating system management functions. The TrueCopy local commands perform the same functions as the remote commands but within the same RAID storage system instead of between two RAID storage systems. Data replication operations with CCI 6 17

206 TrueCopy, ShadowImage, and Universal Replicator operations TrueCopy/ShadowImage volumes Figure 6-8 TrueCopy local system configuration TrueCopy commands allow you to create volume pairs consisting of one primary volume (P-VOL) and one secondary volume (S-VOL). The TrueCopy P-VOL and S-VOL can be in different storage systems. TrueCopy provides synchronous and asynchronous copy modes. TrueCopy Async can only be used between separate storage systems (not within one storage system). For details on TrueCopy specifications, volumes and operations, please see the Hitachi TrueCopy User Guide for your storage system. ShadowImage commands allow you to create volume pairs consisting of one P-VOL and up to nine S-VOLs using the ShadowImage cascade function. ShadowImage pairs are contained within the same storage system and are maintained using asynchronous update copy operations. For details on ShadowImage specifications volumes and operations, please see the Hitachi ShadowImage User Guide for your storage system. Each volume pair that you want to create must be registered in the CCI configuration file. ShadowImage volume pairs must include a MU (mirrored unit) number assigned to the S-VOL. The MU number indicates that the pair is a ShadowImage pair and not a TrueCopy pair. Once the correspondence between the paired logical volumes has been defined in the HORCM_DEV 6 18 Data replication operations with CCI

207 section of the configuration file, you can use the configuration file to group the paired volumes into volume groups that can be managed by the host operating system's LVM (logical volume manager). The host's LVM allows you to manage the TrueCopy/ShadowImage volumes as individual volumes or by volume group. TrueCopy/ShadowImage commands can specify individual logical volumes or group names. For LUSE volumes, you must enter commands for each volume (LDEV) within the expanded LU. If you define volume groups and you want to issue commands to those volume groups, you must register the volume groups in the configuration file. For further information about the server LVM, see the user documentation for your corresponding operating system. TrueCopy/ShadowImage/Universal Replicator pair status Each TrueCopy pair consists of one P-VOL and one S-VOL, and each ShadowImage pair consists of one P-VOL and up to nine S-VOLs when the cascade function is used. Table 6-2 TrueCopy and ShadowImage pair status on page 6-19 lists and describes the TrueCopy and ShadowImage pair status terms. Table 6-3 Universal Replicator pair status on page 6-20 lists and describes the Universal Replicator pair status terms. The P-VOL controls the pair status for the primary and secondary volumes. The major pair statuses are SMPL, PAIR, PSUS/PSUE, and COPY/RCPY. Read and write requests from the host are accepted or rejected depending on the pair status of the volume. The pair status can change when a CCI command is executed. The validity of the specified operation is checked according to the status of the volume (primary volume). Table 6-4 Pair status versus TrueCopy/Universal Replicator commands on page 6-22 shows the relationship between pair status and TrueCopy/ Universal Replicator command acceptance. Table 6-5 Pair status versus ShadowImage commands on page 6-22 shows the relationship between pair status and ShadowImage command acceptance. Table 6-6 Pair status versus Copy-on-Write Snapshot commands on page 6-25 shows the relationship between pair status and Copy-on- Write Snapshot command acceptance. For details on pair status of TrueCopy for Mainframe, ShadowImage for Mainframe, and Universal Replicator for Mainframe, see Pair operations with mainframe volumes on page Table 6-2 TrueCopy and ShadowImage pair status Statu s TrueCopy Pair ShadowImage Pair Primary Secondary SMPL Unpaired volume Unpaired volume R/W enabled PAIR Paired volume. Initial copy is complete. Updates are processed synchronously or asynchronously. Paired volume. Initial copy is complete. Updates are processed asynchronously. R/W enabled R/W enabled R enabled Data replication operations with CCI 6 19

208 Statu s TrueCopy Pair ShadowImage Pair Primary Secondary COPY In paired state, but initial copy, pairsplit, or resync operation is not complete. Includes COPY(PD), COPY(SP), and COPY(RS) status. In paired state, but initial copy, pairsplit, or resync operation is not complete. Includes COPY(PD), COPY(SP), and COPY(RS) status. RCPY Not used for TrueCopy In paired state, but reverse resync operation is not complete. Includes COPY(RS-R) status. PSUS (split) SSUS (split) PSUE (error) or PFUS PDUB In paired state, but updates to the S-VOL data are suspended due to user-requested pairsplit. The RAID storage system keeps track of P-VOL and S-VOL updates while the pair is split. In paired state, but updates to the S-VOL data are suspended due to an error condition. (PSUE is PSUS due to internal error. PFUS is PSUS due to sidefile full.) Used only for TrueCopy LUSE pairs. In paired state, but updates to one or more LDEVs within the LUSE pair are suspended due to an error condition. In paired state, but updates to the S-VOL data are suspended due to user-requested pairsplit. The RAID storage system keeps track of P-VOL and S-VOL updates while the pair is split. In paired state, but updates to the S-VOL volume data are suspended due to an error condition. When a PSUE pair is resynchronized, the RAID storage system copies the entire P-VOL to the S-VOL (same as initial copy). Not used for ShadowImage R/W enabled R enabled R/W enabled R/W enabled if no error occurs in the primary volume R/W enabled if no error occurs in the primary volume R enabled R enabled R/W enabled when using write enable pairsplit option R enabled R enabled Table 6-3 Universal Replicator pair status Statu s Universal Replicator Pair Primary Secondary SMPL Unpaired volume R/W enabled R/W enabled PAIR The pair is synchronized. Updates to the P-VOL are R/W enabled R enabled duplicated on the S-VOL. COPY In paired state, but initial copy, pairsplit, or resync operation is not complete. Includes COPY(PD), COPY(SP), and COPY(RS) status. R/W enabled R enabled 6 20 Data replication operations with CCI

209 Statu s Universal Replicator Pair Primary Secondary PSUS (split) SSUS (split) PSUE PFUS SSWS The user has split the pair or released the pair; the pair is no longer synchronized. The primary and secondary systems keep track of journal data discarded during the pairsplit operation. When the operation is performed at the primary system, the status of both the P-VOL and S-VOL changes to PSUS. When the operation is performed at the secondary system, the status of the S-VOL changes to PSUS; the primary system detects this (if path status is normal) and changes P-VOL status to PSUS. When a pair is released from the secondary system, the secondary system changes the status of the S- VOL to SMPL. The primary system detects this (if path status is normal and changes P-VOL status to PSUS. (The pair must be released from the primary system to change P-VOL status to SMPL.) The pair is suspended due to an error; the pair is not synchronized. The primary and secondary systems keep track of any journal data that are discarded during the suspension operation. The primary system keeps track of P-VOL tracks that are updated while the pair is suspended. When a UR suspension condition is detected, the primary system changes P-VOL and S-VOL status to PSUE. If the secondary system detects the condition, it changes the S-VOL status to PSUE; the primary system detects this and changes P-VOL status to PSUS. If the Data Overflow Watch period is exceeded, pair status changes from PFUL to PFUS, and the pair is suspended. The PFUS status is displayed by CCI and Storage Navigator as PSUS. If a virtual volume of Dynamic Provisioning (DP- VOL) is used as a UR S-VOL, and the capacity of a pool-vol is nearly full, UR status becomes PFUS and the pair is suspended. After Takeover, SSWS is the status of the S-VOL. With this status, data can be written to the S-VOL. SSWS is displayed by CCI, from which the horctakover command is issued. Storage Navigator displays this status as PSUS or PSUE. R/W enabled R/W enabled if no error occurs in the primary volume R/W enabled R enabled R/W enabled when using write enable pairsplit option R enabled Read Only, unless write option is enabled. R/W enabled Data replication operations with CCI 6 21

210 Statu s Universal Replicator Pair Primary Secondary PFUL If data in the journal volume exceeds 80-percent, pair status changes to PFUL. The write data that inflows then is monitored during the Data Overflow Watch. R/W enabled R enabled PFUL status is displayed by CCI. Storage Navigator displays this status as PAIR. Table 6-4 Pair status versus TrueCopy/Universal Replicator commands - TrueCopy/Universal Replicator command paircreate pairsplit pairresync # Copy Nocopy -r or -rw option -P option -S option Resync 1 SMPL Accepted 2 Accepted 3 Rejected Rejected Acceptable Rejected 2 COPY Acceptable Acceptable Accepted 4 Rejected Accepted 1 Acceptable 3 PAIR Acceptable Acceptable Accepted 4 Accepted 4 Accepted 1 Acceptable 4 PSUS Rejected Rejected Acceptable Acceptable Accepted 1 Accepted 2* 5 PSUE Rejected Rejected Acceptable Acceptable Accepted 1 Accepted 2* 6 PDUB Rejected Rejected Rejected Rejected Accepted 1 Accepted 2* Legend: Accepted = Accepted and executed. When the operation terminates normally, the status changes to the indicated number. Acceptable = Accepted but no operation is executed. Rejected = Rejected and operation terminates abnormally. Pairsplit of a TrueCopy Async volume is returned after verification of state transition that waits until delta data is synchronized from P-VOL to S-VOL. Note: In the case of the SSWS status after SVOL-SSUS-takeover execution, the pairresync command (from P-VOL to S-VOL) is rejected because the delta data for S-VOL becomes dominant, and its status is expected to be using the -swaps(p) option of pairresync. If the pairresync command (from P-VOL to S-VOL) is rejected, confirm this special status using the -fc option of the pairdisplay command. The following table shows the relation of command acceptances for paired status and ShadowImage. Table 6-5 Pair status versus ShadowImage commands - ShadowImage command paircreate pairsplit pairresync Pair No -split -split -E option -C option -S option Resync 1 SMPL Accepted 2 Accepted 2 to 4 2 COPY RCPY Acceptable Accepted [1] 2 to 4 Rejected Rejected Acceptable Rejected Accepted 5 Accepted [1] 2 to 4 Accepted 1 Acceptable 6 22 Data replication operations with CCI

211 - ShadowImage command paircreate pairsplit pairresync Pair No -split -split -E option -C option -S option Resync 3 PAIR Acceptable Accepted [2] 2 to 4 Accepted 5 Accepted [2] 2 to 4 Accepted 1 Acceptable 4 PSUS Rejected Acceptable Accepted 5 Acceptable Accepted 1 Accepted 2 5 PSUE Rejected Acceptable Acceptable Acceptable Accepted 1 Accepted 2 Legend: Accepted = Accepted and executed. When the operation terminates normally, the status changes to the indicated number. Acceptable = Accepted but no operation is executed. Rejected = Rejected and operation terminates abnormally. In the following descriptions, when the pair statuses of P-VOL and S-VOL are different, PVOL_ or SVOL_ are applied to show which volume is indicated. Note: If the P-VOL does not have Write in the PAIR state, then data identical with an S-VOL is guaranteed. Therefore, when using the S-VOL with the SMPL state, after stopping Write to the P-VOL, generate a paired volume, and then split the paired volume after confirming that the paired volume has the PAIR status. In the PSUE state, ShadowImage does not manage differential data at the P-VOL or S-VOL. Therefore, pairresync issued to a pair in the PSUE state is all copy performance, but the copy progress rate returned by the -fc option of the pairdisplay command indicates "0%". [1]: The (2 to 4) state change is effective for only the COPY state that is changed without specification of -split for paircreate command. [2]: The (2 to 4) state change appears as P-VOL_PSUS & S-VOL_COPY (see example below), and reading and writing are enabled for S-VOL in SVOL_COPY state. # pairsplit -g oradb # pairdisplay -g oradb -fc Group PairVol(L/R) (Port#,TID,LU-M), Seq#, LDEV#.P/S,, %, P-LDEV# M oradb oradev3(l) (CL2-N, 3, 4-0) P-VOL PSUS, W oradb oradev3(r) (CL2-N, 3, 5-0) S-VOL COPY, PVOL_PSUS & SVOL_COPY is the non-reflected PSUS state that data is still being copied from the P-VOL to the S-VOL, and this state has the following specific behavior. Data replication operations with CCI 6 23

212 If you attempt to read non-reflected data on S-VOL in PVOL_PSUS & SVOL_COPY state, then ShadowImage copies non-reflected data from P- VOL to S-VOL, and returns the correct data after copied. This will bring the performance degradation (1/6 to 1/15 with IOPS) to read on the S- VOL. If you attempt to write non-reflected data on S-VOL in PVOL_PSUS & SVOL_COPY state, then ShadowImage copies non-reflected data from P- VOL to S-VOL, and writing data is managed as delta data for S-VOL after copied. This will bring the performance degradation(1/6 to 1/8 with IOPS) to write on the S-VOL. If you attempt to write to the data on P-VOL that does not still reflected the data to S-VOL, then ShadowImage copies non-reflected data from P-VOL to S-VOL, and writing data is managed as delta data for P-VOL. This will bring the performance degradation(1/6 to 1/8 with IOPS) to write on the P-VOL. The state changes for pairsplit are (WD = Write Disable, WE = Write Enable): If P-VOL has non-reflected data in PAIR state: Behavior of OLD pairsplit at T0 T0 PVOL_PAIR from/to SVOL_PAIR(WD) T1: PVOL_COPY from/to SVOL_COPY(WD) T2: PVOL_PSUS from/to SVOL_SSUS(WE) Behavior of first pairsplit at T0 PVOL_PAIR from/to SVOL_PAIR(WD) PVOL_PSUS from/to SVOL_COPY(WE) PVOL_PSUS from/to SVOL_SSUS(WE) If P-VOL has been reflected all data to S-VOL in PAIR state: Behavior of OLD pairsplit at T0 T0: PVOL_PAIR from/to SVOL_PAIR(WD) T1: PVOL_PSUS from/to SVOL_SSUS(WE) Behavior of First pairsplit at T0 PVOL_PAIR from/to SVOL_PAIR(WD) PVOL_PSUS from/to SVOL_SSUS(WE) The state changes for paircreate -split are: Behavior of OLD paircreate -split at T0 Behavior of First paircreate -split at T0 T0: SMPL from/to SMPL SMPL from/to SMPL T1: PVOL_COPY from/to SVOL_COPY(WD) T2: PVOL_PSUS from/to SVOL_SSUS(WE) PVOL_PSUS from/to SVOL_COPY(WE) PVOL_PSUS from/to SVOL_SSUS(WE) If you attempt the pairevtwait -s psus in PVOL_PSUS & SVOL_COPY state, then pairevtwait will return immediately even if the S-VOL is still in SVOL_COPY state because P-VOL is already in PVOL_PSUS state. If you want to wait the "SVOL_SSUS" state, and then you must check the status of the S-VOL becomes "SVOL_PSUS" via the return code using pairvolchk -ss command on S-VOL side or pairvolchk -ss -c command on P-VOL side. Or you can use pairevtwait -ss ssus on both P-VOL and S-VOL, pairevtwait -ss ssus -l on S-VOL locally. If you attempt the pairresync -restore or pairsplit -S in PVOL_PSUS & SVOL_COPY state, then ShadowImage will reject this command due to unable to perform. In this case, you need to wait until the S-VOL state becomes SVOL_SSUS Data replication operations with CCI

213 Table 6-6 Pair status versus Copy-on-Write Snapshot commands Copy-on-Write Snapshot Command Pair paircreate pairsplit pairresync No -split -split -E option -C option -S option Resync 1 SMPL Accepted 2 Rejected Rejected Rejected Acceptable Rejected 2 COPY Acceptable Rejected Rejected Rejected Rejected Acceptable RCPY 3 PAIR Acceptable Accepted* 4 Rejected Accepted 4 Accepted 1 Acceptable 4 PSUS Rejected Acceptable Rejected Acceptable Accepted 1 Accepted* 2 (PFUS) 5 PSUE Rejected Rejected Acceptable Rejected Accepted 1 Accepted* 2 Accepted*: A command is accepted and issued; whether this command is executed or not depends on the microcode version of the RAID storage system. Note: pairsplit ("simplex -S") of Copy-on-Write Snapshot volume is returned without verification of state transition that waits until SMPL state. In SMPL state, the volume that was S-VOL becomes R/W disable and data is discarded. In the "PSUE" state, Copy-on-Write Snapshot does not manage for differential data between the primary volume and secondary volume. TrueCopy Async, TrueCopy, and Universal Replicator volumes TrueCopy Async/Universal Replicator provides paired volumes that use asynchronous transfer to ensure the sequence of writing data between the primary volume and secondary volume. The sequence of writing data between the primary and secondary volumes is guaranteed within each consistency (CT) group (see Figure 6-9 TrueCopy Async consistency groups on page 6-26). Data replication operations with CCI 6 25

214 Restrictions Figure 6-9 TrueCopy Async consistency groups Group definition of TrueCopy Async/Universal Replicator/TrueCopy volume: All volumes in a group must be contained within the same storage system. If two or more groups of CCI include the same CT group (CTGID), then pair operation of the group specification is handled in CT group entirety. Registration of CTGID number and limitations: CCI registers CTGID to RAID disk array automatically when paired volumes are created by paircreate command, and groups of configuration definition files are mapped to CTGID. The maximum number of CT groups is 256 for Virtual Storage Platform and USP V/VM (CTGID0 to CTGID255), 128 for TagmaStore USP/TagmaStore NSC (CTGID0 to CTGID127), 64 for Lightning 9900 V (CTGID0-CTGID63), and 16 for XP512/XP48 Disk Array (CTGID0 to CTGID15). TrueCopy Async/Universal Replicator pair command is terminated with EX_ENOCTG when the maximum number of CT groups is exceeded. Relationships between CTGID and Journal ID: CT group numbers are used for TrueCopy Async, TrueCopy, and Universal Replicator. The rest of the CT group numbers are used only for Universal Replicator, and are mapped to the journal Data replication operations with CCI

215 Table 6-7 Assignment of consistency group IDs (CTGIDs) CTGID Assignment TrueCopy Asynchronous TrueCopy At-time Split for TrueCopy: The operation for making data consistency is only supported by the following option: pairsplit -g <group>... [-r] pairsplit -g <group>... -rw TrueCopy Async and Universal Replicator volume characteristics TrueCopy Async/Universal Replicator volumes have the following characteristics: PAIR state: A TrueCopy Async pair changes to the PAIR status as soon as all pending recordsets have been placed in the queue at the primary volume, without waiting for the updates to complete at the secondary volume. Pair splitting:when a TrueCopy Async pair is split or deleted, all pending recordsets at the primary volume are sent to the secondary volume, then the pair status changes to PSUS or SMPL. With the pairsplit command only, updates for the primary volume that occur during and after the pairsplit operation are marked on the bitmap of the primary volume. Pair resynchronization: The pairresync command resynchronizes the secondary volume based on the primary volume. This resynchronization does not guarantee the sequenced data transfer. Error suspending: Pending recordsets that have not yet been sent to the secondary volume are marked on the bitmap of the primary volume, then deleted from the queue, and then the pair status changes to PSUE. Group operations: TrueCopy Async automatically registers the CTGIDs with the storage system when paired volumes are created using the paircreate command, and groups in the configuration file are mapped to their corresponding CTGIDs. If more than one group, defined in the configuration definition file, is assigned to the same CTGID, then pair operations on the group specificity apply to the entire consistency group. Sidefile cache for TrueCopy Async CTG Universal Replicator CTG Universal Replicator CTG The first-in-first-out (FIFO) queue of each CT group is placed in an area of cache called the sidefile. The sidefile is used for transferring TrueCopy Async recordsets to the RCU. The sidefile is not a fixed area in cache but has variable capacity for write I/Os for the primary volume. If the host write I/ O rate is high and the MCU cannot transfer the TrueCopy Async recordsets to the RCU fast enough, then the sidefile capacity expands gradually. The sidefile has a threshold to control the quantity of data transfer of host side Data replication operations with CCI 6 27

216 write I/O. Host side write I/Os are controlled by delaying response when the sidefile exceeds the constant quantity limit on cache in the storage system (see Figure 6-10 Sidefile quantity limit on page 6-28). Figure 6-10 Sidefile quantity limit Sidefile area: Sidefile area = 30% to 70% of cache as set on Storage Navigator (default sidefile = 50% for USP V/VM, 9900V; 40% for TagmaStore USP/TagmaStore NSC). Write I/O control via the high-water mark (HWM): When the quantity of data in the sidefile reaches 30% of cache, the TrueCopy Async pair status is HWM of PAIR state, and the host write I/Os receive a delayed response in the range of 0.5 seconds to 4 seconds. Following is an arithmetic expression of the HWM at 100% of a sidefile space: HWM(%) = High water mark(%) / Sidefile threshold (30 to 70) * 100 Write I/O control via the sidefile threshold: When the quantity of data in the sidefile occupies the maximum defined sidefile area, host write I/Os are delayed until there is enough sidefile space to store the next new write data. The copy pending timeout group option is defined using Storage Navigator and specifies the maximum delay between the M-VOL update and the corresponding R-VOL update. The range for the copy pending timeout option is seconds (600 seconds for Universal Replicator), and default value is 90 seconds (60 seconds for UR). If the timeout occurs during this wait state, the pair status changes from PAIR to PSUS (sidefile full), and host write I/Os continue with updates being managed by the cylinder bitmap. Important: The copy pending timeout value should be less than the I/O timeout value of the host system. TrueCopy Async transition states and sidefile control TrueCopy Async volumes have special states for sidefile control during status transitions. Table 6-8 State table for TrueCopy vs. TrueCopy Async on page 6-29 shows the transition states for TrueCopy and TrueCopy Async volumes. The suspending and deleting states are temporary internal states within the RAID storage system. CCI cannot detect these transition states, because these states are reported on the previous state of the storage system. These states are therefore concealed inside the pairsplit command. After the pairsplit command is accepted, host write I/Os for the P-VOL are managed by the cylinder bitmap (normal), non-transmitted data remaining 6 28 Data replication operations with CCI

217 in the P-VOL's FIFO queue is transferred to the S-VOL's FIFO queue, and the pair status is then set to PSUS [SMPL] state when all data in the P-VOL's FIFO queue has been transmitted. PFUL. If the quantity of data in sidefile cache exceeds 30% of cache storage, the internal status of the RAID storage system is PFUL, and host write I/Os receive delayed response in the range of 0.5 seconds (minimum) to 4 seconds (maximum). PFUS. If the quantity of data in sidefile cache exceeds the user-defined sidefile area (30%-70%), then host write I/Os must wait for enough sidefile space to become available for storing the next new write data. If a copy pending timeout occurs during this waiting state, then the pair status changes from PAIR to PFUS, host write I/Os are accepted, and write data is managed by bitmap. The CCI software can detect and report the PFUL and PFUS states as follows: As a return code of the pairvolchk command As the status code displayed to code item by the pairmon command As the paired status displayed to status item using -fc option of pairdisplay command Table 6-8 State table for TrueCopy vs. TrueCopy Async CCI state Storage system internal state TrueCopy Sync Description TrueCopy Async Writing control on TC async volume Writing data Response Transfer data via ESCON SMPL SMPL SMPL Same Normal Usual None COPY COPY COPY Same Via Sidefile Usual* Sidefile & bitmap Deleting N/A Deleting from COPY using Normal Usual Sidefile [pairsplit -S] Suspending N/A Suspending from COPY by Via Bitmap Usual Sidefile using [pairsplit] PAIR PAIR Synchronized Async Less than HWM Via Sidefile Usual Sidefile PFUL N/A sidefile in HWM to use Threshold Via Sidefile Delayed Sidefile Over Threshold Deleting N/A Deleting from PAIR using [pairsplit -S] Suspending N/A Suspending from PAIR Using [pairsplit ] Timeout of over threshold Via Sidefile Wait until under threshold Sidefile Normal Usual Sidefile Via Bitmap Usual Sidefile Data replication operations with CCI 6 29

218 CCI state Storage system internal state TrueCopy Sync Description TrueCopy Async Writing control on TC async volume Writing data Response Transfer data via ESCON PSUS PSUS PSUS Same Via Bitmap Usual None PFUS None Timeout Over Threshold Via Bitmap Usual None PSUE PSUE PSUE Same (link down, etc) Via Bitmap Usual None PDUB PDUB PDUB Same Via Bitmap Usual None * If the host has more write I/Os in COPY state, then host write I/Os are delayed until there is enough space in the sidefile. Legend: Bitmap: Host write data is managed via a cylinder BITMAP of delta data. Normal: Host write data is not managed by BITMAP or sidefile. Usual: Host side writing response is not delayed. HWM (High Water Mark): Sidefile quantity is over 30% of cache storage. TrueCopy Async/Universal Replicator error state In the case of an ESCON or fibre-channel (FC) failure, the S-VOL FIFO queue is missing a data block that was transferred from the P-VOL FIFO queue. The RCU waits to store the next sequenced data block in the S-VOL FIFO queue until the TrueCopy Async copy pending timeout occurs (defined using TrueCopy). In addition, the timeout value can be specified at SVP. The default value is set to 5 minutes. If the timeout occurs during this waiting state, the pair status changes from PAIR to PSUE, and non-sequenced data blocks are managed by the S-VOL bitmap. The missing data block can be recovered using the pairresync command, which merges the S-VOL bitmap with the P-VOL bitmap. Figure 6-11 TrueCopy Async suspension condition on page 6-31 shows this situation on the secondary side Data replication operations with CCI

219 Figure 6-11 TrueCopy Async suspension condition TrueCopy/TrueCopy Async and Universal Replicator fence level settings TrueCopy volume pairs are assigned a fence level for write I/Os to ensure mirroring consistency of critical volumes. When the secondary volume takes over from the primary volume, the takeover action is determined according to the pair status and fence level of the corresponding secondary volume. Table 6-9 Relationship between TrueCopy pair statuses and fence levels on page 6-31 shows the relationship between TrueCopy pair statuses and fence levels. Mirror consistency = Identity and sequence of data is assured via error notification after an I/O completion. Data consistency = Sequence of data is assured in I/O order based on host. Table 6-9 Relationship between TrueCopy pair statuses and fence levels TrueCopy pair status of volume Fence level and write response Data [1] [2] Never [3] Async [4] OK OK OK OK Mirroring consistency assured Mirroring consistency assured Mirroring consistency assured Data consistency assured Data replication operations with CCI 6 31

220 TrueCopy pair status of volume Fence level and write response Data [1] [2] Never [3] Async [4] ERROR OK OK OK Mirroring consistency assured Mirroring consistency not assured Mirroring consistency not assured Data consistency assured ERROR ERROR OK OK Mirroring consistency assured Mirroring consistency assured Mirroring consistency not assured Data consistency assured [1] When the fence level is data: Mirroring consistency is assured, since a write error is returned if mirror consistency with the remote S-VOL is lost. The secondary volume can continue operation, regardless of the status. Note: A P-VOL write that discovers a link down situation will, in addition to returning an error to the host, likely be recorded on [only] the P-VOL side. [2] When the fence level is status: If there is a mirror consistency problem (that is, PSUE) and it is possible to set the S-VOL to PSUE, the P-VOL write completes OK. If the S-VOL cannot be set to PSUE for any reason, the P-VOL write completes with an error. The mirror consistency of the S-VOL depends on its status: PSUE: The secondary volume is dubious. PAIR: The secondary volume can continue operation. [3] When the fence level is never: Writing to the P-VOL is still enabled in the state where mirror consistency to the S-VOL is lost, regardless of whether the secondary volume status is updated or not. Thus, the secondary could have these states: PSUE: The secondary volume is dubious. PAIR: The secondary volume is substantially dubious, since it can continue operation and is also dubious. The P-VOL status must be checked to confirm the mirroring consistency. [4] When the fence level is async: TrueCopy Async/UR uses asynchronous transfers to ensure the sequence of write data between the P-VOL and S-VOL. Writing to the P-VOL is enabled, regardless of whether the S-VOL status is updated or not. Thus the mirror consistency of the secondary volume is dubious (similar to the "Never" fence): PSUE: The S-VOL mirroring consistency is not assured, but the PSUE suspended state ensures the sequence of data for the consistency group; thus, data consistency is also assured during a PSUE state. At a PSUE state, the P-VOL writes still complete and are also noted in a bitmap for future transfer. Due to the use of a bitmap in the suspend state, data consistency is not assured during a copy state resync. PAIR: If the P-VOL and S-VOL are both in a PAIR state, mirror consistency is not assured (may be behind) but data consistency is assured (what has reached the S-VOL is in the proper order). Setting the fence level Data fence level 6 32 Data replication operations with CCI

221 Figure 6-12 Relationship between logs (journal) and data in paired status on page 6-33 shows the relationship between redo log files (journal) and data files. If the S-VOL takes over from the P-VOL in the status shown in Figure 6-12 Relationship between logs (journal) and data in paired status on page 6-33 (where two errors have occurred), the secondary host leaves data (V) unprocessed in the roll-back processing and cannot be recovered completely. Therefore, the fence level of a redo log file must be defined as data. Once the fence level is set to data, the P-VOL returns an error if data may possibly be inconsistent when a write request is issued by the host. Since writing to the data file is not executed due to a write error of the redo log file, the log file stays consistent with the data file. However, when the fence level is set to data, a write I/O error occurs even in the case where operation is suspended due to an error in the S-VOL. Accordingly, duplication becomes meaningless when the S-VOL takes over. Thus, applications using paired volumes with the data fence level should be able to handle write I/O errors properly. For example, the Oracle application creates multiple redo log files by itself (three by default). The fence level can be set to data in this case in which disk errors are permissible by creating multiple files. Figure 6-12 Relationship between logs (journal) and data in paired status Never fence level Because most UNIX file systems (excluding JFS and VxFS) have no journal files, the fence level should be defined as Never. When a takeover by the S- VOL occurs, fsck is executed on the volume and the file system is cleaned up, even if the S-VOL is undefined at the secondary host. The data that is lost depends on how much differential data is contained in the P-VOL when the S-VOL is suspended. During operation, error recovery should be performed when the suspended status (PSUE or PDUB) is detected (when one error occurs). Copy-on-Write Snapshot operations Copy-on-Write Snapshot normally creates virtual volumes for copying on write without specifying LUNs as S-VOLs. However, to use a Copy-on-Write Snapshot volume via the host, it is necessary to map the Copy-on-Write Snapshot S-VOL to a LUN. Therefore, CCI provides a combined command to enable the user or application to use the same CCI command in order to maintain ShadowImage compatibility. Copy-on-Write Snapshot uses two techniques, one called "V-VOL mapping" (or virtual volume mapping) and the other is "Snapshot using copy on write" or "Copy-on-Write Snapshot." Copy-on-Write Snapshot volumes are also Data replication operations with CCI 6 33

222 put into pooling volumes called a "Snapshot pool," and a Snapshot pool is specified as a pool ID when a Snapshot is made. Copy-on-Write Snapshot and volume mapping is illustrated in Figure 6-13 Copy-on-Write Snapshot and volume mapping on page Figure 6-13 Copy-on-Write Snapshot and volume mapping Copy-on-Write Snapshot volumes The specifications for Copy-on-Write Snapshot volumes are: Allowable type of paired volume: The supported volume type is OPEN-V only for P VOL, and OPEN-0V for S VOL. Number of volumes (Copy-on-Write Snapshot) can be paired: This depends on P VOL capacity, Copy-on-Write Snapshot pool capacity, and shared memory capacity on the RAID storage system. Duplicated writing mode: Copying on write. Number of mirror volumes: Thin Image: Up to 1,024 secondary volumes can be defined for each P VOL. Copy-on-Write Snapshot: Up to 64 secondary volumes can be defined for each P VOL. For details on Thin Image or Copy-on-Write Snapshot specifications such as maximum number of mirrored volumes, volumes and operations, please see the Hitachi Thin Image User Guide or Hitachi Copy-on-Write Snapshot User Guide for your storage system Data replication operations with CCI

223 Creating a Copy-on-Write Snapshot pair The CCI command for creating a Thin Image or Copy-on-Write Snapshot pair is the same as for ShadowImage. However, Thin Image pair can only operate up to 64 S-VOLs. Therefore, use raidcom command if you want to operate more than 64 S-VOLs. The RAID storage system determines whether it is a ShadowImage pair or a Thin Image/Copy-on-Write Snapshot pair by the attribute of the S-VOL. The RAID storage system also determines whether it is a Thin Image pair or a Copy-on-Write Snapshot pair by the type of the pool to be used. A Thin Image pair is generated in the following two cases: When a V-VOL (OPEN-0V) is specified as an S-VOL. When a pool for Thin Image is specified as the pool type. A Copy-on-Write Snapshot pair is generated in the following two cases: When a V-VOL (OPEN-0V) is specified as an S-VOL. When a pool for Copy-on-Write Snapshot is specified as the pool type. A V-VOL has the following characteristics: It appears as "OPEN-0V" to identify a V-VOL easily via the SCSI Inquiry or CCI. A V-VOL unmapped to the S-VOL of a Copy-on-Write Snapshot will reply to a SCSI Inquiry, but Reading and/or Writing is not allowed. LDEV will reply the capacity setting as an LU to SCSI Read Capacity. A V-VOL that has become the S-VOL of a Copy-on-Write Snapshot will reply to a SCSI Inquiry, and Reading and/or Writing is allowed. Copy-on-Write Snapshot pair status Each paired volume consists of a primary volume (P-VOL) and a secondary volume (S-VOL). Each volume has the status for controlling the pair state. The P-VOL controls the pair state that is reflected on the status of the S- VOL. The major pair statuses are "SMPL", "PAIR", "PSUS", "COPY", and "RCPY". The status is changed when the CCI command is issued. A read or write request from the host is allowed or rejected according to the status. Data replication operations with CCI 6 35

224 Table 6-10 Copy-on-Write Snapshot Pairing P-VOL Pairing Primary Secondary SMPL Unpaired (Copy-on-Write Snapshot) volume R/W enabled R/W disable 1 PAIR (PFUL) COPY RCPY PSUS (PFUS) PSUE (Error) The Copy-on-Write Snapshot available state allocated the resource. The preparing state allocates the resource for the Copy-on-Write Snapshot. The copying state from Copy-on-Write Snapshot to the primary volume by using restore option. The differences of the updated data of the primary and secondary volume are controlled with copying on write. "PSUS" status due sto an internal failure. The differences of the updated data for the Copyon-Write Snapshot volume are not controlled. R/W enabled R/W enabled R/W enabled R/W enabled R/W enabled 2 R/W disable R/W disable R/W disable R/W enabled R/W disable Notes: 1. V-VOL unmapped to the S-VOL of a Copy-on-Write Snapshot will reply to a SCSI Inquiry, but Reading and/or Writing is not allowed. 2. Reading and writing are enabled, as long as no failure occurs in the primary volume. Pair status relationship to Copy-on-Write Snapshot commands Table 6-11 Pair status relationship to Copy-on-Write Snapshot commands on page 6-36 applies to a Copy-on-Write Snapshot context. It explains 1) what a pair status may be prior to any CCI command execution, 2) what the result would be after giving a CCI command, and 3) what the pair status may be if the CCI command is Accepted. Table 6-11 Pair status relationship to Copy-on-Write Snapshot commands - Copy-on-Write Snapshot Command paircreate pairsplit pairresync Pair No -split -split -E option -C option -S option Resync 1 SMPL Accepted 2 Rejected Rejected Rejected Acceptable Rejected 2 COPY Acceptable Rejected Rejected Accepted* Accepted 1 Acceptable RCPY 3 PAIR Acceptable Accepted*4 Rejected Accepted* Accepted 1 Acceptable 4 PSUS Rejected Acceptable Rejected Accepted* Accepted 1 Accepted*2 (PFUS) 5 PSUE Rejected Rejected Rejected Rejected Accepted 1 Accepted*2 *A command is accepted and issued. Whether this command is executed or not depends on the microcode version of the RAID storage system Data replication operations with CCI

225 Note: pairsplit -S of a Copy-on-Write Snapshot volume is returned without verification of the state transition that waits until SMPL state. In a SMPL state, note that the volume that was an S-VOL becomes R/ W disabled and data is discarded. In the "PSUE" state, Copy-on-Write Snapshot does not manage differential data between the primary volume and secondary volume. Controlling Volume Migration Volume Migration, including external volumes, must be controlled using CLI in a Data Lifecycle Management (DLCM) solution. It is possible to support volume migration (Volume Migration function) and the external connection by operating the current ShadowImage and VDEV mapping of the external connection. Also, it is important to consider the support of Volume Migration on the compatibility based on the current CLI interface, because CCI is supporting ShadowImage and the external connection. For this purpose, CCI makes the CLI interface that works by minimum compatible of the application by specifying the COPY mode for Volume Migration to the CLI of CCI. Specifications for Volume Migration CCI must be mapped to the port for pooling of RAID in order to control the volume of the external connection. Therefore, the external volume needs to be mapped previously to the RAID port without connecting to the host. Following is an execution example of the volume migration executed for LDEV#18. Figure 6-14 Volume Migration configurations (1) Command specification Data replication operations with CCI 6 37

226 CCI operates the volume migration by specifying to the horcm*.conf as same SI and TC, because the volume migration using CCI is necessary to be defined the mapping for the target volume. MU# (of SMPL as SI) that is not used because SI is used for Volume Migration operation. An original volume for the migration is defined as P-VOL. A target volume for the migration is defined as S-VOL. In other words, an original volume is migrated from P-VOL to S-VOL, and the mapping between LDEV and VDEV is swapped after copied. (2) Mapping specification The mapping between LUN and LDEV is maintained for the replying of SCSI- Inquiry in order to make recognize as identical LUN through the host after mapping changes. The way to know whether the mapping is changed or not is possible to use "-fe" option of pairdisplay and/or raidscan command that shows the connection for the external volumes. Also LU of the external connection and LU of RAID Group intermingle on the port for pooling, but can confirm this with the above option of the raidscan command. (3) Group operation It is possible to execute the Volume Migration as a group by describing it to the horcm*.conf, however LU(LDEV), which was mapped to S-VOL after command execution, does not maintain the consistency of the group. In other words, you must consider the volume mapped to the S-VOL after execution as the discarded volume. When HORCM demon is KILLed or the host has crash during group operation, the group aborting the execution of the command has LUN mixed with the external connection and RAID Group as the group. In this case, CCI skips the executed LU and issues the CC (Volume Migration) command to the un-executed LU, and an identical command is executed once again. (4) Using MU# CCI manages the status of TC/SI using MU#, so CCI uses the empty MU# that is managed for SI. Therefore, execute the command of the volume migration in the environment for SI having HORCC_MRCF environment variable. An example is shown below. (5) HORCM instance 6 38 Data replication operations with CCI

227 It is possible to describe the original and target volume for the volume migration to MU# as another group in horcm*.conf for HORCM instance of SI and /or TC. Also, it is possible to define the original and target volume for the volume migration in the horcm*.conf as HORCM instance independent from SI/TC. Commands to control Volume Migration (1) Command for Volume Migration CCI supports the volume migration by adding an option (-m cc) to the paircreate command. paircreate -g <group> -d <pair vol> -m <mode> -vl[r] -c <size> -m <mode> mode = cc (can only be specified for ShadowImage) This option is used to specify the Volume Migration mode. Note: This option cannot be specified with "-split" option in the same command. -vl[r] The -vl option specifies "local", and copies from the local instance LU (P- VOL) to the remote instance LU (S-VOL), an original volume as the local instance LU is migrated from P-VOL to S-VOL, and the physical volume mapping between P-VOL and S-VOL is swapped after copied The -vr option specifies "remote", and copies from the remote instance LU (P-VOL) to the local instance LU (S-VOL), an original volume as the remote instance LU is migrated from P-VOL to S-VOL, and the physical volume mapping between P-VOL and S-VOL is swapped after copied. -c <size> This option is used to specify a track size of the case that copies paired volume at 1-15 extents. In case of stopping Write to P-VOL and copying in a short time, the maximum value 15 is specified. When this option is omitted, it uses a default value of (3) is used for track size. (2) Command for discovering an external volume It is possible to discover the external volumes by using "-fe" option of the raidscan command. raidscan -p <port> -fe -fe This option is used to display the serial# and LDEV# of the external LUNs only mapped to the LDEV. If the external LUN mapped to the LDEV on a specified port does not exist, then this option will do nothing.also if this option is specified, -f[f][g][d] option is not allowed. Data replication operations with CCI 6 39

228 Display example: # raidscan -p cl1-a-0 -fe -CLI PORT# /ALPA/C TID# LU# Seq# Num LDEV# P/S Fence E- Seq# E-LDEV# CL1-A-0 ef SMPL CL1-A-0 ef SMPL CL1-A-0 ef SMPL E-Seq#: Displays the production (serial) number of the external LUN. E- LDEV#: Displays the LDEV# of the external LUN. (3) Command for confirming the status It is possible to confirm the status for Volume Migration by using "-fe" option of the pairdisplay command. pairdisplay -g <group> -fe -fe This option is used to display the serial# and LDEV# of the external LUNs mapped to the LDEV and additional information for the pair volume. This option displays the information above by adding to last column, and then ignores the format of 80 column. This option is invalid if the cascade options (-m all,-m cas) are specified. Display example: Before execution of Volume Migration command: # pairdisplay -g horc0 -fe Group... Seq#,LDEV#.P/S,, Seq#,P-LDEV# M CTG CM EM E-Seq# E-LDEV# horc SMPL ---, horc SMPL ---, H # paircreate -g horc0 -vl -m cc During execution of Volume Migration command, the progress is displayed in the copy %: # pairdisplay -g horc0 -fe Group... Seq#,LDEV#.P/S,, Seq#,P-LDEV# M CTG CM EM E-Seq# E-LDEV# horc P VOL COPY, C horc S VOL COPY, C H After completion of Volume Migration command: 6 40 Data replication operations with CCI

229 Group... Seq#,LDEV#.P/S,, Seq#,P-LDEV# M CTG CM EM E-Seq# E-LDEV# horc P VOL PSUS, C V horc S VOL SSUS, C CM: Displays the copy mode N : Non Snapshot S : Snapshot. For SMPL state, this shows that pair-volume will be created as Copy-on- Write Snapshot. C : Volume Migration EM: Displays the external connection mode H : Mapped E-lun as hidden from the host. V : Mapped E-lun as visible to the host ' - ': Unmapped to the E-lun BH : Mapped E-lun as hidden from the host, but LDEV blockading. BV : Mapped E-lun as visible to the host, but LDEV blockading B : Unmapped to the E-lun, but LDEV blockading E-Seq#: Displays the production (serial) number of the external LUN. Unknown is shown as '-'. E-LDEV#: Displays the LDEV# of the external LUN. 'Unknown' is shown as '-'. (4) Command for discovering an external volume via the device file It is possible to discover the external volumes by using the inqraid command. Example in Linux: # ls /dev/sd*./inqraid -CLI DEVICE_FILE PORT SERIAL LDEV CTG H/M/12 SSID R:Group PRODUCT_ID sdh CL2-G s/s/ss :01-09 OPEN-V sdu CL2-G s/s/ss 000B S:00001 OPEN-0V sdv CL2-G s/s/ss 000B U:00000 OPEN-0V sdw CL2-G s/s/ss 000B E:16384 OPEN-V R:Group: This displays the physical position of an LDEV according to mapping of LDEV in the RAID storage system. RAID Group LDEV mapping R: Group Example in Linux: RAID Level 1 : RAID1 5 : RAID5 6 : RAID6 RAID Group number - Sub number Copy-on-Write Snapshot S-VOL S PoolID number Unmapped U External LUN E External Group number Data replication operations with CCI 6 41

230 # ls /dev/sd*./inqraid /dev/sdh -> CHNO = 0 TID = 1 LUN = 1 [SQ] CL2-G Ser = LDEV =15360 [HITACHI ] [OPEN-V ] HORC = SMPL HOMRCF[MU#0 = SMPL MU#1 = SMPL MU#2 = SMPL] RAID5[Group 1-9] SSID = 0x0100 /dev/sdu -> CHNO = 0 TID = 1 LUN = 14 [SQ] CL2-G Ser = LDEV =2755 [HITACHI ] [OPEN-V ] HORC = SMPL HOMRCF[MU#0 = SMPL MU#1 = SMPL MU#2 = SMPL] E-LUN[Group 00001] SSID = 0x000B SNAPS[PoolID 0001] SSID = 0x000B /dev/sdv -> CHNO = 0 TID = 1 LUN = 15 [SQ] CL2-G Ser = LDEV =2768 [HITACHI ] [OPEN-V ] HORC = SMPL HOMRCF[MU#0 = SMPL MU#1 = SMPL MU#2 = SMPL] E-LUN[Group 08191] SSID = 0x000B UNMAP[Group 00000] SSID = 0x000B /dev/sdw -> CHNO = 0 TID = 1 LUN = 16 [SQ] CL2-G Ser = LDEV =2769 [HITACHI ] [OPEN-V ] HORC = SMPL HOMRCF[MU#0 = SMPL MU#1 = SMPL MU#2 = SMPL] E-LUN[Group 16384] SSID = 0x000B E-LUN[Group 16384] SSID = 0x000B Group: This item shows physical position of an LDEV according to mapping of LDEV in the RAID storage system. LDEV Mapping Display Formats RAID Group RAID1[Group Group number - Sub number] RAID5[Group Group number - Sub number] RAID6[Group Group number - Sub number] Copy-on-Write Snapshot S-VOL SNAPS[PoolID poolid number ] Unmapped UNMAP[Group 00000] External LUN E-LUN[Group External Group number] Relations between "cc" command issues and status The migration volumes can be handled by issuing the CCI commands (pair creation and pair splitting commands). The validity of the specified operation is checked according to the status of the paired volume (primary volume). Table 6-12 Command issues and pairing status transition on page 6-43 shows the relations between the migration volume statuses and command acceptances Data replication operations with CCI

231 Table 6-12 Command issues and pairing status transition Restrictions for Volume Migration Command: Pair Creation Pair Splitting Pairing CC: -m cc Simplex -S (1) SMPL Accepted (2) to (3) (2) to (4) Acceptable (2) COPY Acceptable Accepted (3) PSUS Accepted (1) (4) PSUE PDUB Accepted (1) Legend: Accepted: A command is accepted and executed. When the command execution succeeds, the status changes to that of the shown number. Accepted: A command is accepted and executed. When the command execution succeeds, the status changes to that of the shown number. Acceptable: No operation is executed, though a command is accepted. Blank: Command execution is rejected and the operation terminates abnormally. Other commands and options (for example, pairresync ) for operating a paired-volume are rejected. The "-m cc" option cannot be specified with "-split" option in the same command. Volume Migration must be used within the following restrictions: ShadowImage (HOMRCF). The operation for the volume migration must be operated at the "SMPL" or "PAIR" or "COPY" state. If not, paircreate -m cc command is rejected with EX_CMDRJE or EX_CMDIOE. Also ShadowImage cannot be operated to CC_SVOL moving in Volume Migration. In copying CC_SVOL, the copy operation for the volume migration is stopped, if the ShadowImage pairsplit command is executed. TrueCopy (HORC). The operation for the volume migration must be performed at the "SMPL" or "PSUS" state. If not, paircreate -m cc command is rejected with EX_CMDRJE or EX_CMDIOE. Also HORC cannot be operated to CC_SVOL copying in Volume Migration. On one hand, in copying CC_SVOL, the copy operation for the volume migration is stopped, if pairresync command for of HORC is executed. Data replication operations with CCI 6 43

232 LDEV type for Volume Migration. The volume of the external connection for the volume migration must be mapped to an LDEV as OPEN-V. Universal Replicator MxN configuration and control Overview Policy Universal Replicator supports 4X4 by using sysplex timers on the mainframe. However, open systems do not have an equivalent of sysplex timers on the mainframe, because the SCSI protocol does not have timestamps. If the open system (CCI) has the timestamp as an equivalent of sysplex timers, Universal Replicator supports 4X4 on the open system. CCI: delivers the timestamp(ctq-marker) to the consistency group Storage system (RCU): arbitrates the timestamp (CTQ-Marker) across multiple storage systems connected remote command devices, and then commits the journal data. In this architecture, CCI needs to be running. If CCI has stopped, the storage system (RCU) function does not appear to exist. Therefore, the better architecture is to include the storage system (RCU) function into CCI. CCI already supports the group control across multiple storage systems in the TC_Sync group. This means that CCI can support Universal Replicator MxN on the open system if CCI is capable of delivering the timestamps and committing the Journal data with a CTQ-Marker. Thus, CCI supports UR MxN for open systems in the four ways described in Policy on page All data consistency of the CT group across multiple storage systems is maintained by CCI. The storage system supports only basic functions; there is no relation between storage systems in order to simplify testing and configurations. CCI supports Universal Replicator MxN in the following ways Data replication operations with CCI

233 horcm.conf (1) Delivering the timestamp (CTQ-Marker) CCI (HORCM daemon process) makes a table for the groups registered to the horcm.conf as HORCM_CTQM with startup, and makes the threads for each group that delivers the same timestamp with an increment to the multiple storage systems configured in a group. The thread for a group delivers the same timestamp with increments, as far as a group configured Universal Replicator in the PAIR status. The timestamp is delivered by using Freeze/Q-Marker & Run way as default. The timestamp is maintained in each storage system. CCI includes this timestamp with startup, and then delivers the same timestamp with increments to each storage system. (2) Arbitrating/committing the journal data with CTQ-Marker The thread for a group on HORCM compares the timestamp of S-JNL on each storage system (RCU) as far as a group configured Universal Replicator in PAIR state. Once HORCM detects a matching point of the timestamp (CTQ- Marker) on all storage systems (RCU), it issues an order to commit the Journal data with CTQ-Marker to each storage system (RCU). (3) Propagating Error suspend The thread for a group on HORCM delivers the same timestamp with increments as far as a group configured Universal Replicator in PAIR state. If the PSUE/PFUS state detects at least one storage system, then it notifies another storage system to suspend PSUS in order to keep the state consistent in the CT group. Then the thread stops to deliver the timestamp, and keeps monitoring its CT group with interval of HORCM_CTQM until it becomes PAIR state by next pair-resync. (4) Committing the Journal data inside pairsplit command The pairsplit command makes a suspending state on PAIR state, and inherits to compare the timestamp of S-JNL on each storage system (RCU). If it detects a matching point of the timestamp (CTQ-Marker) on all storage systems (RCUs), then it issues an order to commit the Journal data with Q- Marker to each storage system (RCU), and repeats it until it detects an EOM (End Of Marker) of CTQ-Marker with the pairsplit command. CCI supports TC_Sync group across multiple storage systems, but it does not allow TrueCopy Async (UR) group across multiple storage systems. Therefore, CCI needs to add the group definition (HORCM_CTQM) in order to allow making TrueCopy Async(UR) group across multiple storage systems. Then the HORCM daemon process delivers the timestamps (called the consistency Q-Marker), and commits S-VOL Journal data with Q-Marker to the defined group. Data replication operations with CCI 6 45

234 (1) Defining to control UR MxN CCI supports a way to specify consistency Q-Marker to the specified group by adding "HORCM_CTQM" as a keyword in horcm.conf (see example below). HORCM CTQM #groupinterval (10ms)mode(optional oradb300 where group is to be allowed as a group across multiple storage systems. interval is the interval for the CTQ-Marker, recommended as a few second. mode is the run mode for the CTQ-Marker (timestamp). The default run mode is freeze/run. This does not normally need to be specified. If "run" is specified, then the timestamp is issued without freeze. (2) Specifying different JID into CT group In order to support the MxN configuration, it is necessary to specify a different journal ID (JID) into a CT group corresponding to a CCI group. Thus CCI adds an option to specify Journal ID in horcm.conf. HORCM_LDEV #dev_group dev_name Serial# CU:LDEV(LDEV#) MU# oradb dev :1 02:40 oradb dev :1 02:41 oradb dev :2 02:42 oradb dev :2 02:43 If JID (Journal ID) is specified on horcm.conf as mentioned above, then the paircreate command need not specify Journal ID (-jp <jid> -js <jid>) option. If JID (Journal ID) is not specified on horcm.conf, then Journal ID (-jp <jid> -js <jid>) option of the paircreate command is used. Command specifications pairdisplay command Note: The number at the end of the serial number (for example, :1 or :2) specifies the Journal ID. CCI does not change the command options for supporting Universal Replicator MxN Open. However the output of the command is added so that the command can display the CT group and Q-Marker for each storage system, because the CT group and Q-Marker are managed on each storage system. The output of pairdisplay -v ctg and pairdisplay -v jnl[t] are supported so that the option can display CT group information for each storage system. Following is an example for UR 2x2: 6 46 Data replication operations with CCI

235 # pairdisplay -g ora -v ctg CTG P/S AP U(%) Q-Marker QM-Cnt SF(%) Seq# IFC OT/s CT/m RT/m 000 P-VOL PAIR ON S-VOL PAIR P-VOL PAIR ON S-VOL PAIR # pairdisplay -g ora -v jnl JID MU CTG JNLS AP U(%) Q-Marker Q-CNT D-SZ(BLK) Seq# Num LDEV# PJNN SJNN PJNN SJNN # pairdisplay -g ora -v jnlt JID MU CTG JNLS AP U(%) Q-Marker Q-CNT D-SZ(BLK) Seq# DOW PBW APW PJNN c SJNN c PJNN c3a SJNN c # pairdisplay -g horc0 -v jnl -fe JID MU CTG JNLS AP U(%) Q-Marker Q-CNT D-SZ(BLK) Seq# Num LDEV# CTQM PJSN bb1b SJSN bb1b f PJSN SJSN f Note: CTQM: Displays the last CTQ-Marker that was committed on S- VOL. pairsplit command The pairsplit command does not change the command options for supporting UR MxN Open. However, internal behavior is different from 1x1 UR or TrueCopy Async. (1) pairsplit -r or -rw option Issues Freeze to CT group on each MCU Issues Suspend & Run to make a suspending state for CT group on each MCU Data replication operations with CCI 6 47

236 Searches/commits a minimum matching point of the CTQ-Marker on RCU via MCU (in other words, do Journal Restore with CTQ-Marker) Repeats above until detecting an EOM (End Of Marker) marked on MCU on all RCU via MCU Issues End of Suspend to terminate a suspending state, after committed with EOM (End Of Marker) marked on MCU on all RCU Exception: If an uncommitted state (that is, link failure) is detected while executing its operation, then the operation of committing is aborted on keeping current CTQ-Marker level, and a suspending state terminates without waiting for the EOM (End Of Marker). (2) pairsplit -P option Issues Freeze to CT group on each MCU Issues Suspend & Run to make a suspending state for CT group on each MCU Searches/commits a minimum matching point of the CTQ-Marker on RCU via MCU (in other words, do Journal Restore with CTQ-Marker) Repeats above until detecting an EOM (End Of Marker) marked on MCU on all RCU via MCU Issues End of Suspend to terminate a suspending state Exception: If an uncommitted state (that is, link failure) is detected while executing its operation, then the operation of committing is aborted on keeping current CTQ-Marker level, and a suspending state terminates without waiting for the EOM (End Of Marker). (3) pairsplit -S option Issues Freeze to CT group on each MCU Issues Delete & Run to make a deleting state for CT group on each MCU Searches/commits a minimum matching point of the CTQ-Marker on RCU via MCU (in other words, do Journal Restore with CTQ-Marker) Repeats above until detecting an EOM (End Of Marker) marked on MCU on all RCU via MCU Issues End of Delete to terminate a deleting state, after committed with EOM (End Of Marker) on all RCU Exception: If an uncommitted state(that is, link failure) is detected while executing its operation, then the operation of committing is aborted on keeping current CTQ-Marker level, and a deleting state terminates without waiting for an EOM (End Of Marker). (4) pairsplit -RS option In the case of PAIR state (NO failure): Issues SwapSuspend to make a suspending state for CT group on each RCU 6 48 Data replication operations with CCI

237 Searches/commits a minimum matching point of the CTQ-Marker on RCU via RCU (in other words, do Journal Restore with CTQ-Marker) Repeats above until detecting an EOM (End Of Marker) marked on MCU on all RCU via RCU Issues End of Suspend to terminate a suspending state, after committed with an EOM (End Of Marker) on all RCU Exception: If an uncommitted state (that is, link failure) is detected while executing its operation, then the operation of committing is aborted on keeping current CTQ-Marker level, and a suspending state terminates with detecting at least one EOM (End Of Marker). In the case of Failure (PSUE/PSUS): Issues SwapSuspend to make a suspending state for CT group on each RCU Searches/commits a minimum matching point of the CTQ-Marker on RCU via RCU (in other words, do Journal Restore with CTQ-Marker) Repeats above until detecting an EOM(End Of Marker) marked on all RCU via RCU Issues End of Suspend to terminate a suspending state (5) pairsplit -R option In the case of PAIR state (NO failure): Issues Delete to make a deleting state for CT group on each RCU Searches/commits a minimum matching point of the CTQ-Marker on RCU via RCU (in other words, do Journal Restore with CTQ-Marker) Repeats above until detecting an EOM (End Of Marker) marked on MCU on all RCU via RCU Issues End of Delete to terminate a deleting state, after committed with an EOM (End Of Marker) on all RCU Exception: If an uncommitted state (that is, link failure) is detected while executing its operation, then the operation of committing is aborted on keeping current CTQ-Marker level, and a deleting state terminates with detecting at least one EOM (End Of Marker). In the case of Failure(PSUE/PSUS): Issues Delete to make a deleting state for CT group on each RCU Searches/commits a minimum matching point of the CTQ-Marker on RCU via RCU (in other words, do Journal Restore with CTQ-Marker) Repeats above until detecting an EOM(End Of Marker) marked on all RCU via RCU Issues End of Delete to terminate a deleting state Data replication operations with CCI 6 49

238 Notice on system operation CCI does not change the command options for supporting Universal Replicator MxN Open. However, the output of the command is added so that the command can display the CT group and Q-Marker for each storage system, because the CT group and Q-Marker are managed on each storage system. (1) CT group ID and journal ID for UR The CT group ID must be assigned/used as the unique identifier across multiple storage systems. Therefore, the paircreate command makes a group volume having the same CT group ID across multiple storage systems. (2) Cascading operation The "-FHORC" option for cascading operation does not perform with CTQ- Marker Mode. Hence the cascading volume must not be specified UR MxN volume when using the "-FHORC" option. (3) Running HORCM daemon HORCM daemon process delivers the timestamps (called the consistency Q- Marker) to the defined CT group. Therefore if HORCM daemon is stopped, then UR will stop to delta (commit) and will suspend because of Journal Full state. Thus HORCM daemon must be running to keep the PAIR state. (4) Separating a command device IO from application IO The HORCM daemon process issues IOs to the command device in order to deliver the timestamps to the defined CT group. Therefore, it is recommended to separate the command device path from the application IO path. (5) About waiting application IO The HORCM daemon process delivers the timestamps to the defined CT group while freezing IO for each journal. Waiting Rate = 0.5ms * Number of journal / / Interval (ms) * 100 (Note that 0.5 ms depends on the OS platform.) Therefore it is recommended to limit within four journal per CT group and 8192 LDEVs per CT group. In the case of multiple CT groups per HORCM, it is recommended to limit within 256 LDEVs per CT group Data replication operations with CCI

239 (6) HOST IO on pairsplit -RS, -R, horctakeover, pairresync - swapp(s) The pairsplit -RS, -R operation cannot be frozen and Split HOST IO from RCU in Link Normal state. In other words this option does not support Attime Split, hence these operations are required to stop HOST IO in order to keep Data Consistency on S-VOL. This is the same restriction as TC_Sync. (7) Suspending/deleting status The suspending/deleting for committing S-VOL Journal data with CTQ- Marker is accomplished by the CCI commands. Therefore the storage system has nothing to do in that status (suspending/deleting). If a CCI command is aborted for some reason (KILL, etc.) or EX_EWSTOT, the storage system keeps that status (suspending/deleting). To terminate this status, re-execute the CCI command, then terminate suspending/deleting status after "JNL Consistency Restore". (8) Detecting inconsistent CTQ-Marker The pairsplit command checks data consistency with CTQ-Marker across multiple storage systems. If an inconsistent CTQ-Marker is detected, then it returns with EX_VOLCUR after changed to suspend status. This error needs to confirm if CTQMs are the same on S-VOL on each storage system using the "pairdisplay -v jnl -fe" option. # pairdisplay -g horc0 -v jnl -fe JID MU CTG JNLS AP U(%) Q-Marker Q-CNT D-SZ(BLK) Seq# Num LDEV# CTQM PJSN bb1b SJSN bb1b f PJSN SJSN f (9) About pairsyncwait command Using the Q-Marker with the pairsyncwait command is managed on each Journal including the target device. Therefore the pairsyncwait command must specify a target device (-g <group> -d <pair vol>, or -d <device file>, or -d <serial#> <ldev#>). For example: # pairsyncwait -g horc0 -d dev-002 -t 500 UnitID CTGID Q-Marker Q-Num de8 DONE 0 If group (-g <group>) is specified, then the first dev_name on the specified group is used. Data replication operations with CCI 6 51

240 Explanation of terms: JNL Consistency Restore: commits up as far as MAX CTQ-Marker. JNL Full Restore: commits up to EOM (End of marker for split). JNL Consistency Suspend: suspends after "JNL Consistency Restore" JNL Full Suspend: suspends after "JNL Full Restore" Configuration examples CCI does not change the command options for supporting Universal Replicator MxN Open. However the output of the command is added so that the command can display the CT group and Q-Marker for each storage system, because the CT group and Q-Marker are managed on each storage system Data replication operations with CCI

241 (1) UR 2x2 Data replication operations with CCI 6 53

242 (2) UR 2x Data replication operations with CCI

243 Remote volume discovery In the configuration separating "Storage admin server (CCI server)" and each production server, it is difficult to verify/check the volumes on the production servers and the volumes described to the horcm.conf on CCI server. In this configuration, you cannot use the following CCI capabilities: Command device security pairdisplay -fd option that displays the device file on the production host view raidscan -find verify To solve this configuration problem, CCI supports a way to discover volumes on the remote server by adding the -export option to the inqraid command, and by importing its output via the raidscan -find command. Figure 6-15 Volume discovery Data replication operations with CCI 6 55

244 Discovering a remote volume The inqraid command exports the device information discovered on the production servers. The device information includes "Keyword, Serial#, Ldev#, Device file name..". The raidscan -find inst command on CCI server imports the device information, and registers it into the HORCM daemon. The inqraid command is needed only for discovering LUNs on the production server. (1) inqraid format The inqraid command adds the "-export" option with -CLI for exporting the results of the volume discovery on the remote server. Example from UNIX (Solaris): # ls /dev/rdsk/c1t* inqraid -CLI -export INQRAID:@CL4-G@64015@0@124@OPEN-V-CM@/dev/rdsk/c1t0d0s2 INQRAID:@CL4-G@64015@1@124@OPEN-V-CM@/dev/rdsk/c1t0d1s2 INQRAID:@CL4-G@64015@2@95@OPEN-V@/dev/rdsk/c1t0d2s2 INQRAID:@CL4-G@64015@3@95@OPEN-V@/dev/rdsk/c1t0d3s2 INQRAID:@CL4-G@64015@4@95@OPEN-V@/dev/rdsk/c1t0d4s2 INQRAID:@CL4-G@64015@5@95@OPEN-V@/dev/rdsk/c1t0d5s2 INQRAID:@CL4-G@64015@7@95@OPEN-V@/dev/rdsk/c1t0d7s2 (2) A way to export/import using pipe & SSH Example for exporting from UNIX (Solaris) to CCI host: # ls /dev/rdsk/c1t* inqraid -CLI -export ssh <CCI host> raidscan -find inst DEVICE_FILE Group PairVol PORT TARG LUN M SERIAL LDEV /dev/rdsk/c1t0d2s2 G1 G1-000 CL4-G /dev/rdsk/c1t0d2s2 G1 G1-000 CL4-G /dev/rdsk/c1t0d3s2 G1 G1-001 CL4-G Example for Verifying from UNIX (Solaris) to CCI host: # ls /dev/rdsk/c1t* inqraid -CLI -export ssh <CCI host> raidscan -find verify DEVICE_FILE Group PairVol PORT TARG LUN M SERIAL LDEV /dev/rdsk/c1t0d0s /dev/rdsk/c1t0d1s /dev/rdsk/c1t0d2s2 G1 G1-000 CL4-G /dev/rdsk/c1t0d3s2 G1 G1-001 CL4-G /dev/rdsk/c1t0d4s /dev/rdsk/c1t0d5s /dev/rdsk/c1t0d7s Data replication operations with CCI

245 (3) A way to import with horcmstart.sh on CCI host Example 1 for exporting: # ls /dev/rdsk/c1t* inqraid -CLI -export ssh <CCI host> cat > /etc/horcmperm*.conf OR Example 2 for exporting: # ls /dev/rdsk/c1t* inqraid -CLI -export > /tmp/inqraid.ex ftp "/tmp/inqraid.ex" to "/etc/horcmperm*.conf" on CCI host This example for importing on CCI host executes horcmstart.sh * on the CCI host, where * is the instance number. Display example for verifying on CCI host: # cat /etc/horcmperm*.conf raidscan -find verify DEVICE_FILE Group PairVol PORT TARG LUN M SERIAL LDEV /dev/rdsk/c1t0d0s /dev/rdsk/c1t0d1s /dev/rdsk/c1t0d2s2 G1 G1-000 CL4-G /dev/rdsk/c1t0d3s2 G1 G1-001 CL4-G /dev/rdsk/c1t0d4s /dev/rdsk/c1t0d5s /dev/rdsk/c1t0d7s # pairdisplay -g G1 -fd -l Group PairVol(L/R) Device_File,Seq#,LDEV#.P/ S,,Fence,Seq#,P-LDEV# M G1 G1-000(L) c1t0d2s SMPL , G1 G1-001(L) c1t0d3s SMPL , Data replication operations with CCI 6 57

246 6 58 Data replication operations with CCI

247 7 Data protection operations with CCI This chapter describes data protection operations using CCI. Data protection operations Protection parameters and operations Data Protection facility Data protection operations with CCI 7 1

248 Data protection operations User data files are normally placed on a disk through a software layer such as a file system, LVM, disk driver, SCSI protocol driver, bus adapter, and SAN switching fabric. Data corruption can happen due to software layer bugs or human error. CCI Data Protection Facility does not prevent these types of errors. On the other hand, the purpose of data protection is to prevent writing to volumes that the RAID storage system is guarding. Data protection functions include: Data Retention Utility Volume Retention Manager Volume Security Encryption License Key Database Validator Data Retention Utility The purpose of the Data Retention Utility is to prevent writing to volumes that the RAID storage system is guarding. Data Retention Utility is similar to the command that supports Database Validator, setting a protection attribute for the specified LU. Hide from Inquiry command. The RAID storage system conceals the target volumes from the SCSI Inquiry command by responding "unpopulated volume" (0x7F) to the device type. SIZE 0 volume. The RAID storage system replies with "SIZE 0" to the target volumes through the SCSI Read capacity command. Read protection. The RAID storage system protects reading from the target volumes by responding with the "Illegal function" check condition (SenseKey = 0x05, SenseCode = 0x2200). Write protection. The RAID storage system replies with "Write Protect" in the mode sense header, and protects from writing the target volumes by responding with the "Write Protect" check condition (SenseKey=0x07, SenseCode=0x2700). SVOL disabling. The RAID storage system rejects the command execution of the copy series program product for not to be overwritten the target volume by the copy process of copy series program product (TrueCopy/Universal Replicator/ShadowImage/Copy-on-Write Snapshot), and protects the target volume. This option can be used with the other Data Retention Utility options in parallel. For example, if you want to protect from the writing by the both copy series program product and the host accessing, set the both write protection option and this option. Only the setting of write protection option cannot protect the target volume from the writing executed by the copy processing of the copy series program product. 7 2 Data protection operations with CCI

249 Restrictions on Data Retention Utility volumes Database Validator File systems using Data Retention Utility When setting DRU to the UNIX file system volumes, the volumes must be mounted with the Read Only option after the volumes are unmounted. If DRU is set to the volumes as they are in the mounted status, unexpected behavior may occur in the system. When using a file system for Write Protect Mode set disk on Windows Server 2003/Windows Server 2008/Windows Server 2012, use the "- x mount" and "-x umount" CCI command options with the above mentioned procedures. Data Retention Utility volumes set to Write Protect Mode (Read ONLY) cannot be used for the Windows NT/Windows 2000 file system (NTFS, FAT). LVM(VxVM) on Data Retention Utility If changing LVM configuration including Data Retention Utility, use the raidvchset -vg command for setting the status of the target volume checking prohibited temporarily. Also, after the completion of LVM configuration change, set again the status as checking. Data Retention Utility in HA Cluster Server If HA Cluster software writes to the metadata at regular intervals to confirm whether its disks are available or not, then Data Retention Utility should not be used in HA environments. Dynamic disk on Windows systems Data Retention Utility volumes cannot be used for the dynamic disk, because the dynamic disk does not handle the volumes set to Write Protect Mode (Read ONLY). Data Retention Utility volumes must be used for basic disks only. LUN#0 Some operating systems cannot recognize LUNs over LUN#1 if LUN#0 has the Data Retention Utility "inv" attribute set. This is because some HBA drivers do not scan all LUNs on a port if LUN#0 is invisible. Database Validator prevents data corruption in an Oracle database by checking Oracle data validation before an Oracle data block is written on a disk. Data Block corruption: This occurs when Oracle data is corrupted by some intervening software layer and/or hardware components. The RAID storage system can check the validity of the data block before the Oracle data block is written to disk. Data block address corruption: The OS (file system, LVM, Disk driver) may write blocks to the wrong location. The RAID storage system can check the validity of the data block address to verify that the Oracle data block is written to the correct location on disk. Data protection operations with CCI 7 3

250 Protection of Oracle volume: Oracle data files might be overwritten by a non-oracle application or by human operation using a command. The RAID storage system can protect volumes storing Oracle files by preventing the volumes from being modified by another application or by human error. Restrictions on Database Validator Oracle tablespace location File system-based Oracle files are not supported by Database Validator. All Oracle database files must be placed on raw volumes (including LVM raw volumes) directly. If host-based striping is used on raw volumes, then the stripe size must be an exact multiple of the Oracle block size. Oracle redo log files (including archive logs) must be on separate volumes with respect to the data files (including control files). In other words, Oracle redo log files and the data files must not be mixed on the same LU. Restoring Oracle files Before restoring Oracle data files from a backup, data validation may need to be temporarily turned off for those data files that were backed up prior to the Oracle checksum being enabled. Old blocks may exist on disk without checksum information in them if the database was running without checksum enabled in the past. Oracle on LVM(VxVM) LVM block size must be a multiple of the Oracle block size. The Oracle block size must be less than or equal to the minimum of the LVM stripe size and the largest block size at which LVM will not fracture (known as "Logical Track Group" in LVM), which is 256 KB in LVM. When adding new physical volumes (PVs) to a logical volume (LV) to be used as an Oracle data file, control file, or online log, the data validation should be re-enabled in order to have HARD checking take effect on those new PVs. Similarly, in order to have HARD checking no longer performed on PVs that have been removed from an LV that had previously been used by Oracle, HARD checking should be explicitly disabled on the device corresponding to the PV. If host-based mirroring is used such as LVM mirroring, all component PV mirrors must be HARD-enabled, otherwise the entire logical volume (LV) is exposed. That is, if a user takes an unmirrored HARDenabled LV, then makes it mirrored on the fly without HARD-enabling all sides of the mirror, that entire LV is exposed to data corruption. LVM bad block relocation is not allowed on PVs that are HARDenabled. Oracle and LVM (VxVM) on HA Cluster Server 7 4 Data protection operations with CCI

251 If HA Cluster software writes to LVM metadata at regular intervals to confirm whether its disks are available or not, change the check area which is set for the target LU (except management area) by using the "-vs <bsize> SLBA ELBA" option. Protection parameters and operations The RAID storage systems have protection checking parameters for each LU, and these parameters are set through CCI and its command device. CCI supports the following commands to set and verify the parameters for protection checking for each LU: raidvchkset: Sets the protection checking parameter for the specified volumes. raidvchkdsp: Shows the protection checking parameter for the specified volumes based on the CCI configuration definition file. raidvchkscan: This command has three different uses depending on the options used with the command. Shows the fibre port, target ID, LDEV, and validation checking parameters for the specified volumes based on the raidscan command. Shows the journal volume list setting and information for the journal volume. Shows the Copy-on-Write Snapshot pool setting and information for the Copy-on-Write Snapshot pool. Data Protection facility The Data Protection Facility permits main operations to volumes that you can see on the host, and prevents wrong operations. CCI controls protected volumes at the result of recognition of protection. CCI recognizes only volumes that the host shows. For that purpose LUN Security is provided for the CCI environment. The Data Protection Facility ON/OFF is controlled by the security setting for the command device, as shown in the following table. Table 7-1 Security setting for command device Command device setting Security User authentication Group information acquisition Security to be set No security Only HORCM_DEV allowed User authentication required User authentication required Only HORCM_DEV allowed CMD security Data protection operations with CCI 7 5

252 Command device setting Security User authentication Group information acquisition Security to be set CMD security Only HORCM_DEV allowed CMD security User authentication required CMD security User authentication required Only HORCM_DEV allowed Notes: Only HORCM_DEV allowed : means to be able to perform the operation for only paired logical volumes described at HORCM_DEV. User authentication required: means that only the commands issued by the authorized users can be executed. CMD security: means that only the devices recognizable from the host can be operated. The Data Protection Facility uses an enhanced command device that you define using the LUN Manager software (or SNMP). When you define the command device, the DataProtection Facility is turned ON or OFF to each command device, which has an attributes to enable the Data Protection Facility. CCI distinguishes the ON from OFF attribute when CCI recognizes the command device. Figure 7-1 Definition of the protection volumes on page 7-6 shows the definition of protected volumes. Note: If the command device is set to enable protection mode, there is no impact on CCI operations. CCI controls pairs under current specification. For details about the command operations when the Data Protection Facility is turned ON, see Target commands for protection on page 7-9. Figure 7-1 Definition of the protection volumes Data Protection Facility specifications Only the permitted volumes can be registered in horcm.conf. When creating the horcm.conf file, describe volumes only from the view that the host shows. CCI manages mirror descriptors (TrueCopy, ShadowImage/ MU#0/1/2) as a unit. The Data Protection Facility has two specifications: 7 6 Data protection operations with CCI

253 one must be a volume that you can see from the host such as the Inquiry tool, and the other must be a mirror descriptor volume that was registered in horcm.conf. The following table shows the registration for the mirror descriptor. Table 7-2 Registration for the mirror descriptor Volumes in horcm.c onf Mirror Descriptor in horcm.conf ShadowImage TrueCopy MU#0 MU#1 MU#2 E none E none E none E none Unknown /dev/ rdsk/ c0t0d0 permitted volumes - permitted volumes - permitted volumes CCI permits operation after the permission command at startup of HORCM. The target is volume that was registered in the horcm.conf file. The permission command is necessary to permit the protected volume at first. The permission command compares an identification for volumes of horcm.conf to all of own host volumes, and the result is registered within HORCM. And HORCM makes tables for protected volume and permitted volumes from horcm.conf and Inquiry result. Inquiry result is based on configuration of Data Retention Utility. When controlling pair volumes, requests to protected volumes are rejected with error code EX_ENPERM. The Data Protection Facility is based on the host side view at the result of Data Retention Utility. You need to configure Data Retention Utility before CCI operation. CCI checks Data Retention Utility by Inquiry within CCI. The Data Protection Facility can be enabled separately for each command device. If you want to use protection and non-protection modes in the same storage system at the same time, you can define two (or more) command devices: one with protection ON, one with protection OFF. Protection mode is enabled for the host that has Data Retention Utility and ON command device. Examples for configuration and protected volumes - permitted volumes Unknown Legend: E: Mirror descriptor volume to be registered in horcm.conf. Unknown: Volumes that own host cannot recognize, even though volumes were registered in horcm.conf. Case (1): Two Hosts (Figure 7-2 Example for the two-host configuration on page 7-8). In protect mode Ora2 are rejected to operate the paired volume, because of Unknown for Grp4 on HOST2. - Data protection operations with CCI 7 7

254 Case (2): One Host (Figure 7-3 Example for the one-host configuration on page 7-8). In protect mode Ora1 and Ora2 are rejected to operate the paired volume, because of Unknown for Grp2 and Grp4 on HOST1. If HOST1 has a protection OFF command device, then Ora1 and Ora2 are permitted to operate the paired volume. Note: The Data Protection Facility is implemented by only CCI. CCI needs to know the protection attribute for the command device whether should be permitted the operation for paired volume. If HORCM has protection ON command device at its time, then HORCM checks a permission for a paired volume. Figure 7-2 Example for the two-host configuration Figure 7-3 Example for the one-host configuration 7 8 Data protection operations with CCI

255 Operation authority with CMD security enabled If the CMD security is enabled, you have the operation authority for the LU which meets both of the following requirements. The connection to the host has been recognized when you start CCI. The LU is the target of the pair operation specified with MU# which is defined in the configuration definition file. For the volumes that you do not have the operation authority, "****" is displayed as the LDEV#, and "----" is displayed as the status. If you perform the pair operations, CCI rejects the request with the error code "EX_ENPERM" (pairdisplay is not included). If you specify 0, for the MU#, your operation authority is limited on the LUs for the local copy program products (ShadowImage, ShadowImage for Mainframe and Copy-on-Write Snapshot). If you specify h0, h1 or h2 for the MU#, your operation authority is limited on the LUs for the remote copy (TrueCopy, TrueCopy for Mainframe, TrueCopy Async, Universal Replicator and Universal Replicator for Mainframe) operations. If you specify nothing for the MU#, you have the operation authority on MU#0 for the local copy and the remote copy operations. Target commands for protection The following commands are controlled by the Data Protection Facility: horctakeover, paircurchk, paircreate, pairsplit, pairresync, pairvolchk, pairevtwait, pairsyncwait, raidvchkset, raidvchkdsp, pairdisplay. When the command is issued to non-permitted volumes, RAID Manager rejects the request with error code "EX_ENPERM" (pairdisplay is not included). The pairdisplay command shows all volumes, so that you can confirm non-permitted volumes. Non-permitted volumes are shown without LDEV# information. As shown below, the LDEV# information is " **** " (-CLI is " "). # pairdisplay -g oradb Group PairVol(L/R) (Port#,TID,LU-M),Seq#, LDEV#.P/S,, Seq#,P-LDEV# M oradb oradev1(l) (CL1-D, 3, 0-0) ****..- -,- - oradb oradev1(r) (CL1-D, 3, 1-0) ****..- -,- - The raidscan command shows all volumes same as current specification, because it does not need HORCM_DEV and HORCM_INST on horcm.conf. If you want to know permitted volumes at raidscan, use raidscan -find. The -find option shows device file name and storage system information by using internal Inquiry result. You can use raidscan -find to make horcm.conf, because only permitted volumes are shown with host side view. Following is an example for HP-UX systems: # ioscan -fun grep rdsk raidscan -find DEVICE_FILE UID S/F PORT TARG LUN SERIAL LDEV PRODUCT_ID /dev/rdsk/c0t3d0 0 F CL1-D Data protection operations with CCI 7 9

256 permission command OPEN-3 /dev/rdsk/c0t3d1 0 F CL1-D OPEN-3 CCI recognizes permitted volumes at the result of the permission command. The permission command is the -find inst option of raidscan. This option issues an inquiry to a specified device file to get Ser# and LDEV# from the RAID storage system, and checks an identification for volumes of horcm.conf to all of own host volumes, then stores the result within HORCM of the instance. This permission command is started by / etc/horcmgr automatically. The following example shows the relation between the device file and horcm.conf for a manual operation on an HP-UX system. All volumes of ioscan are permitted. # ioscan -fun grep rdsk raidscan -find inst DEVICE_FILE Group PairVol PORT TARG LUN M SERIAL LDEV /dev/rdsk/c0t3d0 oradb oradev1 CL1-D /dev/rdsk/c0t3d0 oradb oradev1 CL1-D New options for security raidscan -find inst This option registers the device file name to all mirror descriptors of the LDEV map table for CCI and permits the matching volumes on horcm.conf in protection mode. It is started from /etc/horcmgr automatically. You will not normally need to use this option. This option issues an Inquiry to a device file from the result of STDIN. Then CCI gets Ser# and LDEV# from the RAID storage system. Subsequently, CCI compares the Inquiry result to the contents of horcm.conf, and the result is stored within HORCM for the instance. At the same time CCI shows the result of this option about the relation. This option will also be terminated to avoid wasteful scanning after registration based on horcm.conf, because HORCM does not need the registration any more. # ioscan -fun grep rdsk raidscan -find inst DEVICE_FILE Group PairVol PORT TARG LUN M SERIAL LDEV /dev/rdsk/c0t3d0 oradb oradev1 CL1-D /dev/rdsk/c0t3d0 oradb oradev1 CL1-D Note: When multiple device files share the same LDEV, the first device file is registered to the LDEV map table. raidscan -find verify [MU#] This option shows the relation between group on horcm.conf and Device_File registered to the LDEV map tables from DEVICE_FILE of STDIN Data protection operations with CCI

257 raidscan -f[d] pairdisplay -f[d] # ioscan -fun grep rdsk raidscan -find verify -fd DEVICE_FILE Group PairVol Device_File M SERIAL LDEV /dev/rdsk/c0t3d0 oradb oradev1 c0t3d /dev/rdsk/c0t3d1 oradb oradev2 Unknowm /dev/rdsk/c0t3d Note: It shows shared LDEV among multiple device files, if there is a difference between DEVICE_FILE and Device_File. You can also use this option to the command device that specified non-protection mode. It is used for the purpose to see the relation between DEVICE_FILE and the group of horcm.conf. This option shows the Device_File that was registered on the group of HORCM, based on the LDEV (as defined in the local instance configuration definition file). # raidscan -p cl1-d -fd Port#,TargetID#,Lun#..Num(LDEV#...)...P/S,,Fence,LDEV#,Device_File CL1-D, 3, 0...1(17)...SMPL - - -,c0t3d0 CL1-D, 3, 1...1(18)...SMPL - - -,c0t3d1 This option shows the relation between the Device_File and the paired volumes (protected volumes and permitted volumes), based on the group, even though this option does not have any relation with protection mode. # pairdisplay -g oradb -fd Group PairVol(L/R) Device_File M,Seq#,LDEV#.P/S,, Seq#,P-LDEV# M oradb oradev1(l) c0t3d P-VOL COPY, oradb oradev1(r) c0t3d S-VOL COPY, If either the local or the remote host (instance) has not been shown the Device_File, then pair operations are rejected (except the local option such as "-l") in protection mode because of Unknown volume, as shown in the following example. # pairdisplay -g oradb -fd Group PairVol(L/R) Device_File M,Seq#,LDEV#.P/S,, Seq#,P-LDEV# M oradb oradev1(l) c0t3d P-VOL COPY, oradb oradev1(r) Unknown ****..- -, Permitting protected volumes Protection mode needs recognition step to check accessible volumes and the horcm.conf at the startup of HORCM on protection mode. The protected volumes must be registered to enable the Data Protection Facility at each startup of HORCM, so that this registration process is executed automatically by /etc/horcmgr. Data protection operations with CCI 7 11

258 With a $HORCMPERM file The following is executed for registration of permitted volume file ($HORCMPERM file), if $HORCMPERM file exists and there are permitted volumes. To permit only the volumes specified, then the volume list must be defined in the $HORCMPERM file. Naming of $HORCMPERM file on UNIX systems $HORCMPERM is /etc/horcmperm.conf or /etc/horcmperm*.conf (* = instance number) by default. For example, on HP-UX systems: cat $HORCMPERM /HORCM/usr/bin/raidscan -find inst # The following are an example to permit the LVM Volume groups. # For MU# 0 vg00 /dev/rdsk/c0t3d0 /dev/rdsk/c0t3d1 vg00 /dev/rdsk/c0t3d2 /dev/rdsk/c0t3d3 # For MU# 1 vg01 /dev/rdsk/c0t3d0 /dev/rdsk/c0t3d1 vg01 /dev/rdsk/c0t3d2 /dev/rdsk/c0t3d3 Verifying a group for vg01. The following are examples how to verify whether a LVM volume group is mapped to group (MU#1 for ShadowImage) in the horcm.conf file correctly. # export HORCC_MRCF=1 # cat /etc/horcmperm.conf grep vg01 raidscan -find verify 1 - fd OR # vgdisplay -v /dev/vg01 grep dsk sed 's/\/*\/dsk\//\/rdsk\// g' raidscan -find verify 1 -fd DEVICE_FILE Group PairVol Device_File M SERIAL LDEV /dev/rdsk/c0t3d0 oradb1 oradev1 c0t3d /dev/rdsk/c0t3d1 oradb1 oradev2 c0t3d /dev/rdsk/c0t3d2 oradb oradev3 c0t3d /dev/rdsk/c0t3d Naming of $HORCMPERM file on Windows systems $HORCMPERM is %windir%\horcmperm.conf or %windir%\horcmperm*.conf (* = instance number) by default. type $HORCMPERM x:\horcm\etc\raidscan.exe -find inst # The following are an example to permit the DB Volumes. # Note: a numerical value is interpreted as Harddisk#. # DB0 For MU# 0 Hd0-10 harddisk12 harddisk13 harddisk17 # DB1 For MU# 1 hd20-23 Verifying a group for DB1. The following is an example of how to verify whether a DB volume group is mapped to a group (MU#1 for ShadowImage) in the horcm.conf file correctly Data protection operations with CCI

259 D:\HORCM\etc> set HORCC_MRCF=1 D:\HORCM\etc> echo hd20-23 raidscan -find verify 1 -fd DEVICE_FILE Group PairVol Device_File M SERIAL LDEV Harddisk20 oradb1 oradev1 Harddisk Harddisk21 oradb1 oradev2 Harddisk Harddisk22 oradb oradev3 Harddisk Harddisk Without a $HORCMPERM file: Commands to run on different operating systems If NO $HORCMPERM file exists, run a command on the host to permit all volumes on the host. Table 7-3 Without a $HORCMPERM file: Commands to run on different operating systems on page 7-13 shows the command to run on each operating system. Table 7-3 Without a $HORCMPERM file: Commands to run on different operating systems System HP-UX Linux zlinux Solaris AIX Tru64 UNIX Digital UNIX DYNIX/ptx IRIX64 OpenVMS Windows Command echo /dev/rdsk/* /dev/rdisk/* /dev/rcdisk/* /HORCM/usr/bin/raidscan -find inst ls /dev/sd* /HORCM/usr/bin/raidscan -find inst ls /dev/sd* /dev/dasd* /HORCM/usr/bin/raidscan -find inst ls /dev/rdsk/* /HORCM/usr/bin/raidscan -find inst lsdev -C -c disk grep hdisk /HORCM/usr/bin/raidscan -find inst ls /dev/rdisk/dsk* /HORCM/usr/bin/raidscan -find inst ls /dev/rrz* /HORCM/usr/bin/raidscan -find inst /etc/dumpconf -d grep sd /HORCM/usr/bin/raidscan -find inst ls /dev/rdsk/*vol /dev/rdsk/*/*vol/* /HORCM/usr/bin/raidscan -find inst /HORCM/usr/bin/raidscan -pi '$1$DGA DKA DGA ' -find inst X:\HORCM\etc\raidscan.exe -pi $PhysicalDrive -find inst Note: This registration process has risk because it is executed automatically by /etc/horcmgr without judgment for protection mode in order to validate the -fd option. This registration brings a degradation in horcmstart.sh, but HORCM daemon has been running as usual, and it will depend on how many devices a host has. To start faster at HORCM faster in non-protection mode, create the $HORCMPERM file of "SIZE 0 byte" as a dummy file or to set HORCMPERM=MGRNOINST. At this time, the -fd option shows Device_File name as Unknown, and after you can use raidscan - find inst to validate the -fd option. Data protection operations with CCI 7 13

260 Environment variables $HORCMPROMOD This environment variable turns protection mode ON as specified in the following table. If your command device is set for non-protection mode, this parameter sets it to protection mode. Table 7-4 Relation between HORCMPROMOD and command device Command Device HORCMPROMOD Mode Protection mode Don't care Protection mode Non-protection mode Not specified Non-protection mode Specified Protection mode $HORCMPERM This variable is used to specify the HORCM permission file name. If no file name is specified, /etc/horcmperm.conf or /etc/horcmperm*.conf (* = instance number) is the default. If a HORCM permission file exists, then /etc/horcmgr executes the following command to permit the volumes specified. Example for UNIX systems: cat $HORCMPERM /HORCM/usr/bin/raidscan -find inst Example for Windows systems: type $HORCMPERM x:\horcm\etc\raidscan.exe -find inst If no HORCM permission file exists, then /etc/horcmgr executes a builtin command to permit all volumes of a host. See Without a $HORCMPERM file: Commands to run on different operating systems on page 7-13 for examples of commands run on an operating basis. /etc/horcmgr does not execute the built-in command if the following is defined for $HORCMPERM. This is used to execute a system command to permit the volumes specified from a user's shell script. HORCMPERM=MGRNOINST. Determining the protection mode command device The inquiry page is not changed for a command device with protection mode ON. Therefore, CCI provides how to find the protection mode command device. To determine the currently used command device, use the horcctl -D command. This command shows the protection mode command device by adding an asterisk (*) to the device file name. Example for HP-UX systems: # horcctl -D Current control device = /dev/rdsk/c0t0d0* - * indicates protection ON Data protection operations with CCI

261 8 Examples of using CCI commands This chapter provides examples of typical tasks performed using CCI commands. Group version control for mixed storage system configurations LDM volume discovery and flushing for Windows Special facilities for Windows systems Host group control Using CCI SLPR security Examples of using CCI commands 8 1

262 Group version control for mixed storage system configurations Before executing each option of a command, CCI checks the facility version of the storage system internally to verify that the same version is installed on mixed storage system configuration. If the configuration includes older storage systems (for example, 9900V), this method may not meet the requirements for the mixed storage system environment, because the older storage system limits the availability enhancements in later facility versions. If the facility versions of the storage systems are different, you cannot use TagmaStore USP/TagmaStore NSC-specific facility, because CCI applies the minimum version to all storage systems. To expand the capability for mixed storage system configurations and avoid problems such as this, CCI supports the following group version control to manage a version for each group. CCI (HORCM daemon) makes a facility version for each group based on a configuration file at the startup of HORCM. In a mixed storage system configuration, if the facility version of the storage systems (for example, USP V/VM and TagmaStore USP/ TagmaStore NSC) is different on a group, CCI will apply the minimum version for each group (see the following figure). Figure 8-1 Definition of the group version LDM volume discovery and flushing for Windows Windows systems support the Logical Disk Manager (LDM) (such as VxVM), and a logical drive letter is typically associated with an LDM volume (\Device\HarddiskVolumeX). Therefore, you cannot know the relationship between LDM volumes and the physical volumes of the RAID storage system. Therefore, you need to create the CCI configuration file, and you need to know the relationship that is illustrated in Figure 8-2 LDM volume configuration on page Examples of using CCI commands

263 Volume discovery function Figure 8-2 LDM volume configuration CCI supports the volume discovery function on three levels showing the relationship between LDM volumes and the physical volumes. Physical level. CCI shows the relationship between PhysicalDrive and LDEV by giving $Physical as a KEY WORD for the discovery. LDM volume level. CCI shows the relationship between [LDM volume and PhysicalDrives] and LDEV by given $Volume as KEY WORD for the discovery. Drive letter level. CCI shows the relationship between [Drive letter and LDM volume and PhysicalDrives] and LDEV by given $LETALL as KEY WORD for the discovery. The KEY WORD ($Physical, $Volume, $LETALL)can be used with raidscan -find, inqraid, mkconf commands. In Windows, DOS devices (for example, C:, Volume{}) are linked to a Device Object Name (\Device\...). CCI indicates as the following by abbreviating a long Device Object Name. Device Object Name of the LDM for Windows: \Device\HarddiskVolumeX for Partition : \VolX\DskY DskY shows that VolX are configured through HarddiskY. Device Object Name of the LDM for Windows 2003/2000: \Device\HarddiskDmVolumes\... \VolumeX for spanned volume : \DmsX\DskYs Examples of using CCI commands 8 3

264 \Device\HarddiskDmVolumes\... \StripeX for striped volume : \DmtX\DskYs \Device\HarddiskDmVolumes\... \RaidX for Raid-5 volume : \DmrX\DskYs DskYs shows that DmsX(DmtX,Dmr) volumes are configured through bundling multiple HarddiskY1 Y2. Device Object Name of the PhysicalDrive for Windows: \Device\HarddiskX\DR?? : HarddiskX You can determine the relationship between LDM volumes and LDEV by given a KEY WORD to the inqraid command. inqraid $LETALL -CLI DEVICE_FILE PORT SERIAL LDEV CTG H/M/12 SSID R:Group PRODUCT_ID D:\Vol2\Dsk DDRS-34560D E:\Vol44\Dsk0 CL2-K s/s/ss :01-10 OPEN-3 F:\Vol45\Dsk0 CL2-K s/s/ss :01-10 OPEN-3 G:\Dmt1\Dsk1 CL2-K s/s/ss :01-11 OPEN-3 G:\Dmt1\Dsk2 CL2-K s/s/ss :01-11 OPEN-3 G:\Dmt1\Dsk3 CL2-K s/s/ss :01-11 OPEN-3 inqraid $Volume -CLI DEVICE_FILE PORT SERIAL LDEV CTG H/M/12 SSID R:Group PRODUCT_ID \Vol2\Dsk DDRS-34560D \Vol44\Dsk0 CL2-K s/s/ss :01-10 OPEN-3 \Vol45\Dsk0 CL2-K s/s/ss :01-10 OPEN-3 \Dmt1\Dsk1 CL2-K s/s/ss :01-11 OPEN-3 \Dmt1\Dsk2 CL2-K s/s/ss :01-11 OPEN-3 \Dmt1\Dsk3 CL2-K s/s/ss :01-11 OPEN-3 inqraid $Phy -CLI DEVICE_FILE PORT SERIAL LDEV CTG H/M/12 SSID R:Group PRODUCT_ID Harddisk0 CL2-K s/s/ss :01-10 OPEN-3 Harddisk1 CL2-K s/s/ss :01-11 OPEN-3 Harddisk2 CL2-K s/s/ss :01-11 OPEN-3 Harddisk3 CL2-K s/s/ss :01-11 OPEN-3 Harddisk DDRS-34560D Device Object Name of the Partition for Windows NT \Device\HarddiskX\PartitionY : \DskX\pY Device Object Name of the PhysicalDrive for Windows NT 8 4 Examples of using CCI commands

265 \Device\HarddiskX\Partition0 : HarddiskX inqraid $LETALL -CLI DEVICE_FILE PORT SERIAL LDEV CTG H/M/12 SSID R:Group PRODUCT_ID D:\Dsk0\p DDRS-34560D E:\Dsk1\p1 CL2-K s/s/ss :01-10 OPEN-3 F:\Dsk1\p2 CL2-K s/s/ss :01-10 OPEN-3 inqraid $Phy -CLI DEVICE_FILE PORT SERIAL LDEV CTG H/M/12 SSID R:Group PRODUCT_ID Harddisk DDRS-34560D Harddisk1 CL2-K s/s/ss :01-11 OPEN-3 You want to know the relationship between LDM volumes and a group of the configuration files, and then find a group of the configuration file by giving a KEY WORD to raidscan -find verify command. raidscan -pi $LETALL -find verify DEVICE_FILE Group PairVol PORT TARG LUN M SERIAL LDEV E:\Vol44\Dsk0 ORA ORA_000 CL2-K F:\Vol45\Dsk0 ORA ORA_000 CL2-K G:\Dmt1\Dsk1 ORB ORB_000 CL2-K G:\Dmt1\Dsk2 ORB ORB_001 CL2-K G:\Dmt1\Dsk3 ORB ORB_002 CL2-K raidscan -pi $LETALL -find DEVICE_FILE UID S/F PORT TARG LUN SERIAL LDEV PRODUCT_ID E:\Vol44\Dsk0 0 F CL2-K OPEN-3 F:\Vol45\Dsk0 0 F CL2-K OPEN-3 G:\Dmt1\Dsk1 0 F CL2-K OPEN-3 G:\Dmt1\Dsk2 0 F CL2-K OPEN-3 G:\Dmt1\Dsk3 0 F CL2-K OPEN-3 Mountvol attached to Windows 2012/2008/2003/2000 systems Pay attention to the mountvol /D command attached to a Windows system, such that it does not flush the system buffer associated with the specified logical drive. The mountvol command shows the volume mounted as Volume{guid} as follows: mountvol Creates, deletes, or lists a volume mount point... MOUNTVOL [drive:]path VolumeName MOUNTVOL [drive:]path /D Examples of using CCI commands 8 5

266 MOUNTVOL [drive:]path /L \\?\Volume{56e4954a-28d a408-3ff9a6521e5d}\ G:\ \\?\Volume{bf48a395-0ef6-11d5-8d69-00c00d003b1e}\ F:\ You can determine what \\?\Volume{guid}\ is configured, as follows: inqraid $Volume{bf48a395-0ef6-11d5-8d69-00c00d003b1e} -CLI DEVICE_FILE PORT SERIAL LDEV CTG H/M/12 SSID R:Group PRODUCT_ID \Vol46\Dsk1 CL2-K S/s/ss :01-10 OPEN-3 raidscan -pi $Volume{bf48a395-0ef6-11d5-8d69-00c00d003b1e} -find DEVICE_FILE UID S/F PORT TARG LUN SERIAL LDEV PRODUCT_ID \Vol46\Dsk1 0 F CL2-K OPEN-3 System buffer flushing function The logical drive to be flushed can be specified by the following two methods. One method is that the logical drive (for example, G:\hd1 drive, as below) is specified immediately, but this method must know about the logical drive corresponding to a group before executing the sync command. Also the volume is mounting by a directory and this method requires finding its volume name. To solve such a complication, CCI supports a method that flushes the system buffer associated with a logical drive through finding a volume{guid} corresponding to a group of the configuration file. This method does not depend on mounted point, so that it is possible to flush the volume mounted by a directory. This method is supported to be specified a group to the raidscan -find sync command. Figure 8-3 LDM volume flushing 8 6 Examples of using CCI commands

267 The following example flushes the system buffer associated with the ORB group through $Volume. raidscan -pi $Volume -find sync -g ORB [SYNC] : ORB ORB_000[-] -> \Dmt1\Dsk1 : Volume{bf48a395-0ef6-11d5 8d69-00c00d003b1e} [SYNC] : ORB ORB_001[-] -> \Dmt1\Dsk2 : Volume{bf48a395-0ef6-11d5 8d69-00c00d003b1e} [SYNC] : ORB ORB_002[-] -> \Dmt1\Dsk3 : Volume{bf48a395-0ef6-11d5 8d69-00c00d003b1e} The following example flushes the system buffer associated with all groups for the local instance. raidscan -pi $Volume -find sync [SYNC] : ORA ORA_000[-] -> \Vol44\Dsk0 : Volume{56e4954a-28d a408-3ff9a6521e5d} [SYNC] : ORA ORA_000[-] -> \Vol45\Dsk0 : Volume{56e4954a-28d a408-3ff9a6521e5e} [SYNC] : ORB ORB_000[-] -> \Dmt1\Dsk1 : Volume{bf48a395-0ef6 11d5-8d69-00c00d003b1e} [SYNC] : ORB ORB_001[-] -> \Dmt1\Dsk2 : Volume{bf48a395-0ef6 11d5-8d69-00c00d003b1e} [SYNC] : ORB ORB_002[-] -> \Dmt1\Dsk3 : Volume{bf48a395-0ef6 11d5-8d69-00c00d003b1e} Note: Windows NT does not support the LDM volume, so specify $LETALL instead of $Volume. Offline backup using raidscan-find sync for Windows file system: The raidscan-find sync command flushes the system buffer associated with a logical drive through finding a Volume{guid} corresponding to a group of the configuration file, without using the -x mount and -x umount commands. The following examples are for group ORB. P-VOL Side Close all logical drives on the P-VOL by application. Flush the system buffer for P-VOL using raidscan -pi $Volume -find sync -g ORB. Split the paired volume using pairsplit -g ORB with r/w mode. Open all logical drives on the P-VOL by application. Resynchronize the paired volume using pairresync -g ORB. S-VOL Side Flush the system buffer for NEW S-VOL data using raidscan -pi $Volume -find sync -g ORB. Back up the S-VOL data. Flush the system buffer for S-VOL updates using raidscan -pi $Volume - find sync -g ORB when the backup is finished. Online backup using raidscan-find sync for Windows file system: The raidscan-find sync command flushes the system buffer associated with a logical drive through finding a Volume{guid} corresponding to a group of the configuration file, without using the -x mount and -x umount commands. The following examples are for group ORB. Examples of using CCI commands 8 7

268 P-VOL Side Freeze DB on opening P-VOL by application. Flush the system buffer for P-VOL using raidscan -pi $Volume -find sync -g ORB. Splits the paired volume using pairsplit -g ORB with r/w mode. Unfreeze DB on opening P-VOL by application. Resynchronize the paired volume using pairresync -g ORB. S-VOL Side Flush the system buffer for NEW S-VOL data using raidscan -pi $Volume -find sync -g ORB. Back up the S-VOL data. Flush the system buffer for S-VOL updates using raidscan -pi $Volume -find sync -g ORB when the backup is finished. Offline backup using raidscan-find sync for Windows NT file system: The raidscan-find sync command flushes the system buffer through finding a logical drive corresponding to a group of the configuration file, without using the -x mount and -x umount commands. The following examples are for group ORB. P-VOL Side Close all logical drives on the P-VOL by application. Flush the system buffer for P-VOL using raidscan -pi $LETALL -find sync -g ORB. Split the paired volume using pairsplit -g ORB with r/w mode. Open all logical drives on the P-VOL by application. Resynchronize the paired volume using pairresync -g ORB. S-VOL Side Back up the S-VOL data. Flush the system buffer for S-VOL updates using raidscan -pi $LETALL -find sync -g ORB when the backup is finished. Online backup using raidscan-find sync for Windows NT file system: The raidscan-find sync command flushes the system buffer through finding a logical drive corresponding to a group of the configuration file, without using the -x mount and -x umount commands. The following examples are for group ORB. 8 8 Examples of using CCI commands

269 P-VOL Side S-VOL Side Freeze DB on opening P-VOL by application. Flush the system buffer for P-VOL using the raidscan -pi $LETALL - find sync -g ORB. Splits the paired volume using pairsplit -g ORB with r/w mode. Unfreeze DB on opening P-VOL by application. Resynchronize the paired volume using pairresync -g ORB. Back up the S-VOL data. Flush the system buffer for S-VOL updates using raidscan -pi $LETALL -find sync -g ORB when the backup is finished. Note: P-VOL side must stop the WRITE IO to the logical drive corresponding to a [-g name] before issuing the raidscan -find sync command. S-VOL side must close the logical drive corresponding to a [-g name] before issuing the raidscan -find sync command. Special facilities for Windows systems CCI provides the following special facilities for Windows systems: Signature changing facility for Windows systems on page 8-9 GPT disk for Windows on page 8-11 Signature changing facility for Windows systems Consider the following Microsoft Cluster Server (MSCS) configuration in which a MSCS P-VOL is shared from MSCS Node1 and Node2, and the copied volume of S-VOL is used for backup on Node2. If the Node2 has reboot on standby state, then MSCS of Node2 has a problem to assign drive letter of S-VOL with previous P-VOL drive letter. This problem will happen on Node2 on MSCS environment as shown in the following figure. The conditions are: Node1 is active. Node2 is standby state where P-VOL on Node2 is hidden by MSCS, and reboots the Node2. Figure 8-4 Configurations with MSCS and ShadowImage (HOMRCF) Examples of using CCI commands 8 9

270 MSCS on Node2 will misunderstand the S-VOL as MSCS cluster resource, because the signature of S-VOL and P-VOL is the same due to copied. The reason is that MSCS cluster resources are managed with the signature only. Therefore S-VOL of Node2 will unable to backup so that MSCS of Node2 carry away the S-VOL. This is a problem of MSCS service because Windows system does change the signature through reboot if the same signature is detected on NO MSCS service. MSCS will not accommodate LUNs with duplicate signatures and partition layout. The best way to avoid such problems is to transport to another host outside the cluster, but this enforces to set up a backup server, so CCI supports a facility to put back the signature as a second way. The signature can be changed by using the dumpcfg.exe command attached to Windows resource kits, but if the S-VOL is created with the Noread option and the system is rebooted, then the dumpcfg.exe command will fail to change the signature, because the system does not know the signature and volume layout information for S-VOL. CCI adopts the following way with this point in view: You must save the signature and volume layout information to the system disk by using the inqraid -gvinf command, after an S-VOL has set the signature and new partition by the Windows disk management. You can put back the signature by setting the signature and volume layout information to an S-VOL that was saved to the system disk by using the inqraid -svinf command, after splitting the S-VOL. If the S- VOL is created with the Noread option and the system is rebooted, then the system cannot create a device object (\Device\HarddiskVolume#) and Volume{guid} for S-VOL, but the -svinf option will create a Device object (\Device\HarddiskVolume#) and Volume{guid} without using the Windows disk management. Note: The Cluster Disk Driver does not allow using the Noread volume as [Device is not ready] at the boot time, since the Cluster Disk Driver is a Non-Plug and Play Driver. Verify this situation using the inqraid command as follows: inqraid $Phy -CLI DEVICE_FILE PORT SERIAL LDEV CTG H/M/12 SSID R:Group PRODUCT_ID Harddisk Harddisk In this case, do the following to disable the Cluster Disk Driver: 1. In the Computer Management window, double-click System Tools, and then click Device Manager. 2. On the View menu, click Show Hidden Devices. Non-Plug and Play Drivers appear in the list in the right pane. 3. Open Non-Plug and Play Drivers, right-click Cluster Disk, and then click Disable. When prompted to confirm whether to disable the cluster disk, click Yes. When prompted to restart the computer, click Yes. 4. Verify that you can see the Noread volume using inqraid command as follows Examples of using CCI commands

271 inqraid $Phy -CLI DEVICE_FILE PORT SERIAL LDEV CTG H/M/12 SSID R:Group PRODUCT_ID Harddisk0 CL2-K s/s/ss :01-10 OPEN-3 Harddisk1 CL2-K s/s/ss :01-11 OPEN-3 5. After starting up CCI and splitting the S-VOL, put back the signature by using the inqraid -svinf command. 6. Again, in the Computer Management window, enable the Cluster Disk Driver, and restart the computer. GPT disk for Windows Windows supports the basic disk called GPT disk using GUID partition instead of the Signature. The GPT disk also can be used as an S-VOL of the BC. Therefore, CCI supports saving/restoring the GUID DiskId of the GPT Basic disk to the inqraid command. gvinfex option (Windows 2012 only) This option retrieves the LUN signature and volume layout information by way of a raw device file provided via STDIN or arguments, and saves it in a system disk file with the following format: \WindowsDirectory\VOLssss_llll.ini where ssss = serial# llll = LDEV# Normally, this option is used to save the Disk signature/ GUID DiskId and volume layout information once, after it has been written on a potential (and before its paircreate). You do not need to directly view these host files. For example, saves the volume information for all physical drives: D:\HORCM\etc>inqraid $Phys -gvinfex -CLI \\.\PhysicalDrive10: # Harddisk10 -> [VOL61459_448_DA7C0D91] [OPEN-V ] \\.\PhysicalDrive11: # Harddisk11 -> [VOL61459_449_D4CB5F17-2ADC-4FEE-8650 D E8F5] [OPEN-V ] \\.\PhysicalDrive12: # Harddisk12 -> [VOL61459_450_9ABDCB73-3BA E94 22E3798C3B61] [OPEN-V ] -svinfex[=ptn] option (Windows 2003 only) This option writes LUN signature/guid DiskId and volume layout information (that had previously been saved in a system disk file) by way of a raw device file provided via STDIN or arguments. This option gets the serial# and LDEV# of the RAID storage system for the target device using SCSI Inquiry, and writes the signature/guid DiskId and volume layout information from the VOLssss_llll.ini file to the target device. Examples of using CCI commands 8 11

272 This option will work correctly (even if Harddisk# changes due to configuration changes) because the signature/guid DiskId and volume layout information is associated the array serial# and LDEV# (not Harddisk#). [=PTN] This option specifies a string pattern usable to select only the pertinent output lines being provide from STDIN. If used as shown, only the pairdisplay output lines containing Harddisk would be used to cause signature writing. D:\HORCM\etc>pairdisplay -l -fd -g URA inqraid - svinfex=harddisk [VOL61459_448_DA7C0D91] -> Harddisk10 [OPEN-V ] [VOL61459_449_D4CB5F17-2ADC-4FEE-8650-D E8F5] -> Harddisk11 [OPEN-V ] [VOL61459_450_9ABDCB73-3BA E94-22E3798C3B61] -> Harddisk12 [OPEN-V ] -gplbaex option (Windows 2012/2008 Only) This option is used for displaying usable LBA on a Physical drive in units of 512 bytes, and is used to specify [slba] [elba] options for raidvchkset command. C:\HORCM\Tool>inqraid -CLI -gplbaex hd10,13 Harddisk10 : SLBA = 0x f ELBA = 0x013fe5d9 PCNT = 1 [OPEN-V ] Harddisk11 : SLBA = 0x ELBA = 0x013fffdf PCNT = 2 [OPEN-V ] Harddisk12 : SLBA = 0x ELBA = 0x013fffdf PCNT = 3 [OPEN-V ] SLBA: displays usable starting LBA in units of 512 bytes ELBA: displays usable ending LBA (ELBA -1) in units of 512 bytes PCNT: displays the number of partitions Directory mount facility for Windows systems The attached mountvol command into Windows supports the directory mount, but it does not support the directory mount function that flushes the system buffer associated to a logical drive such as in UNIX systems. The directory mount structure on Windows is only symbolical link between a directory and Volume{guid}, illustrated in Figure 8-5 Directory mount structure on page 8-13 below. As such, CCI supports the function to discover the mounted volumes by a directory, and supports the operation to mount/unmount with the subcommand option Examples of using CCI commands

273 Figure 8-5 Directory mount structure Volume discovery for directory mounted volume: CCI can discover the directory mounted volume by using $LETALL that shows the relationship between logical drive and the physical volumes. The KEY WORD ($LETALL)can also be used with the raidscan -find and mkconf commands. D:\HORCM\etc>inqraid $LETALL -CLI DEVICE_FILE PORT SERIAL LDEV CTG H/M/12 SSID R:Group PRODUCT_ID D:\Vol2\Dsk DDRS-34560D D:\hd1\Vol8\Dsk0 CL2-F s/s/ss :01-01 OPEN-3 D:\hd2\Vol9\Dsk1 CL2-F s/s/ss :01-01 OPEN-3 G:\Dms1\Dsk2 CL2-K s/s/ss :01-11 OPEN-3 G:\Dms1\Dsk3 CL2-K s/s/ss :01-11 OPEN-3 G:\Dms1\Dsk4 CL2-K s/s/ss :01-11 OPEN-3 Subcommand for directory mounted volume: CCI supports the directory mount with the -x mount,-x unmount,-x sync option so that the directory mount can be used to mount/unmount the S-VOL. Mount and Sync used Volume{GUID} for Windows: CCI supports the mountcommand option specified in the device object name, such as \Device\Harddiskvolume X. Windows changes the device number for the device object name after recovering from a failure of the PhysicalDrive. As a result, the mountcommand specified in the device object name may fail. Therefore, CCI supports a mountcommand option that specifies a Volume{GUID} as well as the device object name. Examples of using CCI commands 8 13

274 Mount Examples: The mountcommand option specifies a Volume{GUID} as well as the device object name. If a Volume{GUID} is specified, then it is executed by converting a Volume{GUID} to a device object name. Discover the Volume{GUID}s by using inqraid $Volu -fv command option. C:\HORCM\etc>inqraid -CLI $Vol -fv DEVICE_FILE PORT SERIAL LDEV CTG H/M/12 SSID R:Group PRODUCT_ID Volume{cec25efe-d3b8-11d4-aead-00c00d003b1e}\Vol3\Dsk0 CL2-D OPEN-3-CVS-CM [ Mount used DefineDosDevice() ] Note: This may forcibly dismount the mounted volume due to LOG-OFF of Windows. For example: C:\HORCM\etc>raidscan -x mount E: Volume{cec25efe-d3b8-11d4-aead- 00c00d003b1e} E: <+> HarddiskVolume3 [ Mount used Directory mount ] Note: This prevents the forcible removal of a volume due to LOG-OFF of Windows. For example: C:\HORCM\etc>raidscan -x mount E:\ Volume{cec25efe-d3b8-11d4-aead- 00c00d003b1e} E:\ <+> HarddiskVolume3 sync Example: The synccommand option will also be able to specify a Volume{GUID} as well as the device object name. If a Volume{GUID} is specified, then it is executed by converting a Volume{GUID} to a device object name. C:\HORCM\etc>raidscan -x sync Volume{cec25efe-d3b8-11d4-aead- 00c00d003b1e} [SYNC] Volume{cec25efe-d3b8-11d4-aead-00c00d003b1e} Host group control The RAID storage systems have the defined host group in the port and can allocate a host LU for every host group. CCI does not use this host LU, and specifies an absolute LUN in the port. To eliminate confusion that LUN of the CCI notation does not correspond to LUN on the host view and Storage Navigator, CCI supports specifying a host group and LUN on the host view. Specifying a host group (1) Defining the formats 8 14 Examples of using CCI commands

275 The addition of arguments for the host group to the raidscan command and the configuration file means that it is not compatible with conventional CLI. Therefore, CCI provides a way to support CLI by specifying a host group in the port strings as follows. CL1-A-GRP# (GRP# can be up to 127) Specifying the host group for the raidscan command: raidscan -p CL1-A-5 Specifying the host group for the configuration file: #dev_group dev_name port# TargetID LU# MU# ORA ORA_000 CL2-D ORA ORA_001 CL2-D If the port including a host group is specified to the port name, then a maximum of 255 LUNs can be specified. (2) Specifiable port strings As a result, CCI supports four kinds of forms for the port name. Specifying the port name without a host group CL1-A CL1-An where n: unit ID for multiple RAID Specifying the port name with a host group CL1-A-g CL1-An-g where g: host group where n-g: host group=g on CL1-A in unit ID=n Commands and options including a host group (1) Specifiable command for host group The following commands can specify a host group with the port strings: raidscan -p <port>, raidar -p <port>, raidvchkscan -p <port> # raidscan -p CL2-D-1 PORT# /ALPA/C,TID#,LU#.Num(LDEV#...)...P/S,,Fence,LDEV#,P-Seq#,P-LDEV# CL2-D-1 /da/ 0, 4, 0.1(256)...SMPL , CL2-D-1 /da/ 0, 4, 1.1(257)...SMPL , CL2-D-1 /da/ 0, 4, 2.1(258)...SMPL , (2) Command option including a host group CCI supports new option for the following commands in order to show a LUN on the host view by finding a host group via the specified device. raidscan -pdg <device>, raidar -pdg <device>, raidvchkscan - pdg <device> # raidscan -pdg /dev/rdsk/c57t4d1 PORT# /ALPA/C,TID#,LU#.Num(LDEV#...)...P/S,,Fence,LDEV#,P-Seq#,P-LDEV# Examples of using CCI commands 8 15

276 CL2-D-1 /da/ 0, 4, 0.1(256)...SMPL , CL2-D-1 /da/ 0, 4, 1.1(257)...SMPL , CL2-D-1 /da/ 0, 4, 2.1(258)...SMPL , Specified device(hgrp=1) is LDEV# 0257 raidscan -findg # ls /dev/rdsk/c57* raidscan -findg DEVICE_FILE UID S/F PORT TARG LUN SERIAL LDEV PRODUCT_ID /dev/rdsk/c57t4d0 0 F CL2-D OPEN3-CVS-CM /dev/rdsk/c57t4d1 0 F CL2-D OPEN3-CVS /dev/rdsk/c57t4d2 0 F CL2-D OPEN3-CVS raidscan -findg conf, mkconf -gg # ls /dev/rdsk/c57* raidscan -findg conf 0 -g ORA HORCM_DEV #dev_group dev_name port# TargetID LU# MU# # /dev/rdsk/c57t4d1 SER = LDEV = 257 [ FIBRE FCTBL = 4 ] ORA ORA_000 CL2-D # /dev/rdsk/c57t4d2 SER = LDEV = 258 [ FIBRE FCTBL = 4 ] ORA ORA_001 CL2-D inqraid -fg # ls /dev/rdsk/c57*./inqraid -CLI -fg DEVICE_FILE PORT SERIAL LDEV CTG H/M/12 SSID R:Group PRODUCT_ID c57t4d0 CL2-D OPEN-3-CVS-CM c57t4d1 CL2-D s/p/ss :01-02 OPEN-3-CVS c57t4d2 CL2-D s/p/ss :01-02 OPEN-3-CVS Using CCI SLPR security The Virtual Partition Manager feature of the RAID storage systems (USP V/ VM and TagmaStore USP/TagmaStore NSC) supports storage logical partitioning (SLPR), a feature that partitions the ports and volumes of the RAID storage system. If CCI does not have SLPR security, then it can operate the target volumes crossing SLPR through the command device. The purpose of CCI SLPR security is to prevent CCI from operating the volumes on another SLPR (SLPR#N) through the command device from the SLPR (SLPR#M) that is assigned to its Host. You can use CCI SLPR Security by defining the command device through the Virtual Partition Manager feature, so that CCI can protect the target volume. The following example represents the SLPR protection facility Examples of using CCI commands

277 Figure 8-6 Protection of the command device that has the SLPR attribute Legend SLPR : split of storage SLPR#M : split number M of storage Specifying the SLPR Protection Facility When you want to access certain SLPRs on a single Host, use the CCI protection facility so that the Host can access multiple SLPRs through a single command device. The following outline reviews the setup tasks for the SLPR protection facility. 1. Setting SLPR on the command device: The command device has an SLPR number and an associated bitmap so you can set multiple SLPRs. You accomplish this by sharing a command device (using ports connected to different SLPRs) by setting the command device through SLPR#0 (called Storage Administrator) on Storage Navigator. For example, if the command device is shared with the port on SLPR#1 and SLPR#2, then the command device will automatically set the bitmap corresponding to SLPR#1 and SLPR#2. 2. Testing SLPR: CCI verifies whether or not the command device can access a target within SLPR. So, if the command device belongs to SLPR#0, or CCI has no SLPR function, then the SLPR protection is ignored. However, if the command device is shared with the port on SLPR#1 and SLPR#2, CCI allows you to operate the volume on SLPR#1 and SLPR#2. 3. Rejecting commands: If access is denied on the specified port (or target volume), CCI rejects the following commands and outputs an error code, EX_ESPERM: Examples of using CCI commands 8 17

278 horctakeover, paircurchk, paircreate, pairsplit, pairresync, pairvolchk, pairevtwait, pairsyncwait raidscan (except -find verify, -find inst), raidar, pairdisplay raidvchkset, raidvchkscan (except -v jnl), raidvchkdsp [EX_ESPERM] Permission denied with the SLPR [Cause ] : A specified command device does not have a permission to access other SLPR. [Action] : Please make the SLPR so that the target port and the command device belongs to the same SLPR. SLPR configuration examples Single host Figure 8-7 SLPR configuration on a single host on page 8-18 provides an example of when control is denied to the paircreate and raidscan commands in the following cases: The volume described on RMINST1 is different from the SLPR of the command device, so the paircreate command cannot control the paired volume. The specified port is different from the SLPR of the command device, so the raidscan -p CL3-A command cannot scan any ports that are defined as SLPR#N. Figure 8-7 SLPR configuration on a single host To operate SLPR#N, assign the command device. If RMINST1 has been assigned to a command device for SLPR#N, the paircreate command is permitted. However, the raidscan -p CL3-A command (via RMINST0) is unable to scan a port, because the specified port is different than the SLPR of the command device. In this case, -p CL3-A must be operated via RMINST1, as shown in the following example Examples of using CCI commands

279 Figure 8-8 Operation across SLPRs using two command devices on a single host To operate SLPR#N, share the command device. If RMINST1 has a shared command device for SLPR#N, the paircreate command is permitted. Additionally, the raidscan -p CL3-A command (via RMINST0), is permitted to scan a port, because the shared command device has the Bitmap settings SLPR#M and SLPR#N. Figure 8-9 Operation across SLPRs using a shared command device on a single host Examples of using CCI commands 8 19

280 Dual Hosts In the following example, the paircreate command is unable to operate the paired volume because the volume described on HostB is different than the SLPR of the command device. Also, the raidscan -p CL3-A command (via both Hosts), is unable to scan a port because the specified port is different than the SLPR of the command device. Figure 8-10 SLPR configuration on dual hosts To operate SLPR#N, assign the command device. If HostB has a command device for SLPR#N, the paircreate command is permitted. However, the raidscan -p CL3-A command via HostA is unable to scan a port because the specified port is different than the SLPR of the command device. In this case, raidscan -p CL3-A command must be operated via HostB. Figure 8-11 Operation across SLPRs using two command devices on dual hosts 8 20 Examples of using CCI commands

281 To operate SLPR#N, share the command device. If HostB has a shared command device for SLPR#N, the paircreate command is permitted. Also, the raidscan -p CL3-A command (via HostA), is allowed to scan a port because the shared command device has the Bitmap settings SLPR#M and SLPR#N. Figure 8-12 Operating SLPR#N by sharing the command device TrueCopy using dual hosts In the following example, the pair-operation command (except the -l option) determines whether the operation for paired volumes should be permitted at a remote site. The result is that the paircreate command is not allowed to operate the paired volume, because the volume described on HostB differs from the SLPR of the command device. Also, the raidscan - p CL3-A command (on HostB) is not allowed to scan a port. Figure 8-13 TrueCopy operation using SLPR Examples of using CCI commands 8 21

282 8 22 Examples of using CCI commands

283 9 Troubleshooting This chapter provides troubleshooting information for CCI. General troubleshooting Operational notes and restrictions for CCI operations Error messages and error codes Calling the HDS Support Center Troubleshooting 9 1

284 General troubleshooting If you have a problem with the CCI software, first make sure that the problem is not being caused by the UNIX/PC server hardware or software, and try restarting the server. Problem Deprecated SCSI ioctl The following message is output to syslog file(/var/log/ messages) with every ioctl(): program horcmgr is using a deprecated SCSI ioctl, please convert it to SG_IO CCI cannot be started because horcmstart command fails Recommended action CCI currently uses the ioctl(scsi_ioctl_send_command) for sending the control command to the command device. However, in RHEL 4.0 using kernel XX, the following message is output to syslog file(/var/log/messages) with every ioctl(): program horcmgr is using a deprecated SCSI ioctl, please convert it to SG_IO This may originate from the following kernel code in drivers/scsi/ scsi_ioctl.c as way of warning that ioctl(scsi_ioctl_ ) of kernel XX does not properly handle an error of the HBA driver /* Check for deprecated ioctls... all the ioctls that do not follow the new unique numbering scheme are deprecated */ switch (cmd) { case SCSI_IOCTL_SEND_COMMAND: case SCSI_IOCTL_TEST_UNIT_READY: case SCSI_IOCTL_BENCHMARK_COMMAND: case SCSI_IOCTL_SYNC: case SCSI_IOCTL_START_UNIT: case SCSI_IOCTL_STOP_UNIT: printk(kern_warning "program %s is using a deprecated SCSI " "ioctl, please convert it to SG_IO\n", current->comm); Thus, CCI supports a way to change to the ioctl(sg_io) automatically, if Linux kernel supports the ioctl(sg_io) for horcmgr and inqraid command. However, CCI may encounter Linux kernel that does not support the ioctl(sg_io) fully, so CCI also supports by defining either following environment variable or "/HORCM/etc/ USE_OLD_IOCTL" file(size=0) that uses the ioctl(scsi_ioctl_send_command) forcibly. For example: export USE_OLD_IOCTL=1 horcmstart.sh 10 HORCM/etc: -rw-r--r-- 1 root root 0 Nov 11 11:12 USE_OLD_IOCTL -r--r--r-- 1 root sys Nov 10 20:02 horcm.conf -r-xr--r-- 1 root sys Nov 10 20:02 horcmgr If you have changed the configuration definition file settings: make sure that the configuration definition file you changed is correct. If you have changed the settings of the storage system: make sure that the settings you changed are correct, and if necessary, change the configuration definition file settings. Even if there are no problems in these files and settings, but if you cannot run CCI, get all log files under the specified directory by HORCM_LOG (the default setting: /horcm/log/), and then contact the Hitachi Data Systems Support Center. 9 2 Troubleshooting

285 Operational notes and restrictions for CCI operations For maintenance of volumes used by CCI and the HDS features it supports, if a volume failure occurs, it is important to find the failure in the paired volumes, recover the volumes, and continue operation on the original system. When a CCI (HORCM) or HDS feature failure is detected, please collect the data in the error log file and trace data (all files in HORCM_LOG directory), and report the failure to your HDS representative. Items Startup/shutdown restrictions Hot standby operations Coexistence of LVM mirror and TrueCopy Using paired volume in a single host Notes and restrictions When the server starts up, the secondary volume may be updated by the primary volume's server. The secondary volume must not be mounted automatically in the startup sequence. If the secondary volume is used by the LVM, the volume group of the LVM must be deactivated. The secondary volume must be mounted in the split state or in the simplex mode. When the server starts up, the secondary volume can be activated without confirming, when can be guaranteed that the secondary volume has been PSUS (R/W enable) or in the SMPL state by server shutdown sequence. TrueCopy commands cannot execute hot standby operations between the primary and secondary volumes. Use the takeover command intended for the HA configuration to execute the hot standby operation. In hot standby operation, two servers are used, and the active (primary) and standby (secondary) server programs are run alternately in each server in case of a failure in one server. Follow these precautions: Operation across volumes. Since each TrueCopy command causes the server software to handle the volume by volume, a single volume should not be partitioned to prevent it from being used by some servers. Using LVM and TrueCopy together. When constructing the LVM on the paired volume in the mutual hot standby configuration, the LVM logical volumes must be constructed in units of volume to prevent the volumes from being mounted by the LVM. When the LVM mirror and TrueCopy volumes are used together, the LVM mirror handles write errors and changes the volumes. Thus, the fence level of the volumes used by the LVM mirror must be set to data. When constructing paired volume in a single host, it is necessary to activate two or more CCI instances. To activate two or more CCI instances, instance numbers must be assigned using the environment variable HORCMINST. The HORCM and TrueCopy/ ShadowImage commands must possess this environment variable. A configuration definition file and a log directory is set for each instance. For sharing command devices over 17 instances, use SCSI path among the storage system ports to share the command devices. Troubleshooting 9 3

286 Items Sharing volumes in a hot standby configuration Notes and restrictions When paired volume is used for the disk shared by the hosts in hot standby configuration using HA software, use the primary volume as the shared disk and describe the corresponding hosts using the paired volume in the configuration definition file as shown below. In the HA configuration, if a TrueCopy command issued by host C fails in host B (because host B has gone down and/or IO_ERROR of the command device), host A is connected and the command execution is retried. Linkage with HA software Maintenance Command device SCSI alternate path restrictions The HORC Manager must not be an object of the process monitoring by the HA software (cluster manager), because HORCM should run in the same level as the cluster manager. Cooperation with HA software is done by activating the takeover command from the shell script activated by the cluster manager in units of the package software. Note: Cannot use a pair volume for the cluster lock disk that HA software uses for election. Restart of HORCM is required if the storage system configuration is changed (for example, microcode exchange, cache memory install/uninstall). TrueCopy only: In the case of an error (for example, single error in cache memory) which made the pair volume is accompanied by maintenance work, the pairresync or paircreate command cannot execute copy rejection. Each TrueCopy/ShadowImage command is executed by issuing a command to the command device. The TrueCopy/ShadowImage command is read or written from/into the specific block area of the command device. Therefore, the command device cannot be used. In addition, this device must not belong to an LVM volume group. For Windows systems, do not assign a drive letter to the command device to prevent utilization by general users. If the P-VOL and S-VOL are on the same server, alternate path from P-VOL to S-VOL cannot be used. Use of SCSI alternate path to a volume pair in the pair status is limited to among primary (secondary) volumes. Alternate path using Path Manager (Safe Path) is limited to primary volumes. 9 4 Troubleshooting

287 Items horctakeover (Swap-Takeover) HORCM failure to activate Abnormal termination of command Error in paired volume operation Notes and restrictions When executing horctakeover on a standby server manually, I/O on the active server must be stopped. When the package software goes for a standby server a failover by HA software, the HA software must guarantee an I/O insulation of the active server. After a new system has been constructed, a failure to activate HORCM may occur due to improper environment setting and/or configuration definition. Refer to the HORCM activation log, and correct the settings. Refer to the command log file and HORCM log file to identify the cause of the error. If a command terminates abnormally because of a remote server failure, recover the server from the failure, then re-execute the command. If HORCM has shut down, restart HORCM. If an unrecoverable error occurs, obtain the log files and contact the Hitachi Data Systems Support Center. TrueCopy only: If an error occurs in duplicated writing in paired volumes (that is, pair suspension), the server software using the volumes may detect the error by means of the fence level of the paired volume. In such a case, check the error notification command or syslog file to identify a failed paired volume. The system administrator can confirm that duplicated writing in a paired volume is suspended due to a failure and the system runs in regressed state using the error notification command of the TrueCopy. HORCM monitors failures in paired volumes at regular intervals. When it detects a failure, it outputs it to the host's syslog file. Thus, the system administrator can detect the failure by checking the syslog file. Concerning the operation of the RAID storage system, the failure can also be found on Storage Navigator (or SVP) provided. Issue the TrueCopy commands manually to the identified failed paired volume to try to recover it. If the secondary volume is proved to be the failed volume, issue the pair resynchronization command to recover it. If the primary volume fails, delete the paired volume (pair splitting simplex) and use the secondary volume as the substitute volume. Troubleshooting 9 5

288 Items About "/var(usr)/ tmp" directory Notes and restrictions CCI uses "/var/tmp" or "/usr/tmp" as the directory for the UNIX domain socket for IPC (Inter Process Communication), and makes the directory and files as "/var/tmp/.lcm*" in CCI version /06 or later. Caution: This "/var/tmp/.lcm*" should not be removed while HORCM is running. On Red Hat Linux, Cron executes the following "/etc/cron.daily/ tmpwatch" file as default: /usr/sbin/tmpwatch 240 /tmp /usr/sbin/tmpwatch 720 /var/tmp for d in /var/{cache/man,catman}/{cat?,x11r6/cat?,local/ cat?}; do if [ -d "$d" ]; then /usr/sbin/tmpwatch -f 720 $d fi done The command of second line will remove "/var/tmp/.lcm*" directory after 720 Hr from HORCM startup, even though CCI command is used. Action: So administrator needs to add the following command in order to avoid this problem: /bin/touch -c /var/tmp/.lcm* 2>/dev/null /usr/sbin/tmpwatch 240 /tmp /usr/sbin/tmpwatch 720 /var/tmp for d in /var/{cache/man,catman}/{cat?,x11r6/cat?,local/ cat?}; do if [ -d "$d" ]; then /usr/sbin/tmpwatch -f 720 $d fi done Error messages and error codes System log messages The following table lists and describes the HORCM system log messages and provides recommended actions for resolving the error conditions. Table 9-1 System log messages Message ID Condition Cause Recommended action HORCM_001 The HORCM log file cannot be opened. The HORCM trace file cannot be opened. The file cannot be created in the HORCM directory. Create space on the disk on which the root directory resides. HORCM_002 The file cannot be created in the HORCM directory. Create space on the disk on which the root directory resides. 9 6 Troubleshooting

289 Message ID Condition Cause Recommended action HORCM_003 HORCM_004 HORCM_005 HORCM_006 HORCM_007 HORCM_008 HORCM_009 HORCM_101 HORCM_102 The HORCM daemon process cannot create a child process due to an error. HORCM assertion failed, resulting in a fatal internal error in the HORCM. The CCI software failed to create the end point for remote communication. HORCM memory allocation failed. An error exists in the parameter value in the HORCM setup file. HORCM configuration file parameters reading fails. TrueCopy/ ShadowImage connection to the CCI software failed. TrueCopy/ ShadowImage and the CCI software communication fails. The volume is suspended. HORCM daemon attempted to create more processes than the maximum allowable number. An internal error that could not be identified by the HORCM occurred. HORCM failed to create a socket, or an error exists in the format or a parameter in the HORCM configuration file ($HORCM_CONF). HORCM memory could not be secured. An error exists in the parameter value setting in the HORCM setup file. An error exists in the format or parameters of the HORCM configuration file ($HORCM_CONF). System devices are improperly connected, or an error exists in the device parameter in the HORCM configuration file. A system I/O error occurred or an error exists in the device parameter in the HORCM configuration file ($HORCM_CONF). The pair status was suspended due to code XXXX. Terminate unnecessary programs or daemon processes running simultaneously. Restart the system, and contact the Hitachi Data Systems Support Center. Refer to the HORCM startup log to identify the cause of the error. Increase the system virtual memory, or close any unnecessary programs. Refer to the startup log and reset the parameters. Refer to the HORCM startup log to identify the cause of the error. Refer to the HORCM startup log to identify the cause of the error. Refer to the HORCM startup log to identify the cause of the error. Contact the Hitachi Data Systems Support Center. Troubleshooting 9 7

290 Message ID Condition Cause Recommended action HORCM_103 Detected a validation check error on this volume (xxxx unit#x,ldev#x) : CfEC=n, MNEC=n, SCEC=n, BNEC=n A validation error occurs on the database volume, or validation parameters for this volume are illegal. Please confirm the following items, and use raidvchkdsp -v <op> command for verifying the validation parameters. (1)Check if the block size (-vs <size>) is an appropriate size. (2)Check if the type for checking (-vt <type>) is an appropriate type. (3)Check if the data validations are disabled for LVM configuration changes. (4)Check if the data validations are not shared on file system. (5)Check if the redo log and data file are separated among the volumes. Command error messages The following table lists and describes the command error messages and their return values and provides recommended action for resolving the error conditions. They are typical messages of command error messages. Check the command log file for details of the error. For more details about the command log file, see CCI log files on page Table 9-2 Command error messages Error code Error message Condition Recommended action Value EX_COMERR Can't be communicate with HORC Manager This command failed to communicate with the CCI software. EX_REQARG Required Arg list An option or arguments of an option are not sufficient. EX_INVARG Invalid argument An option or arguments of an option are incorrect. EX_UNWOPT Unknown option Designated an unknown option. EX_ATTHOR EX_ATTDBG Can't be attached to HORC Manager Can't be attached to a Debug layer Could not connect with HORCM. Failed to communicate with HORCM, or cannot make a log directory file. Verify that HORCM is running by using UNIX commands [ps - ef grep horcm]. Please designate the correct option using the -h option. Please designate the correct option using the -h option. Please designate the correct option using the -h option. Please verify that HORCM is running and/or that HORCMINST is set correctly. Verify that HORCM is running by using UNIX commands [ps - ef grep horcm] Troubleshooting

291 Error code Error message Condition Recommended action Value EX_INVNAM EX_OPTINV EX_ENOENT Invalid name of option A specified option is invalid No such device or group The name specified in an argument of an option is not appropriate. Detected contradiction in information that RAID reported. The designated device or group name does not exist in the configuration file. EX_ENODEV No such device The designated device name does not exist in the configuration file. EX_ENOUNT EX_ENQSER No such RAID unit The designated RAID unit ID does not exist in the configuration file. Unmatched Serial# vs RAID unitid The group designated by ShadowImage paircreate does not have the same RAID unit, or the unitid is not identical to the unit ID in the same RAID serial# (Seq#). EX_ENOMEM Not enough core Insufficient memory exists. EW_ENESCR Cannot execute script file The script file specified by the -zt option cannot be performed. EX_ERANGE Result too large Your entry is one of the following statuses. The value was entered beyond the maximum. The result value is beyond the maximum. The unit you set is invalid. Please designate the correct name using the -h option. Contact the Hitachi Data Systems Support Center. Verify the device or group name and add it to the configuration file of the remote and local hosts. Verify the device name and add it to the configuration file of the remote and local hosts. Verify the RAID unit ID and add it to the configuration file of the remote and local hosts. Confirm the serial# (Seq#) of the storage system using the pairdisplay command, or confirm that the serial# (Seq#) and the unit ID of storage system are the same among hosts using the raidqry -r command. Increase the virtual memory capacity of the system, or close any unnecessary programs and/or daemon processes. Confirm the execution right, permission the extension, the execution path of the script file. Refer to the error message, and designate an appropriate value or confirm whether you specified the unit correctly. EX_ENAMLG File name too long Undefined error. Contact the Hitachi Data Systems Support Center Troubleshooting 9 9

292 Error code Error message Condition Recommended action Value EX_ENORMT EX_INVMOD EX_INVCMD No remote host alive for remote commands or remote HORCM might be blocked (sleeping) on an existing I/O Invalid RAID command mode Invalid RAID command A timeout occurred on remote communication, and HORC Manager failed to re-execute. Detected a contradiction for a command. Detected a contradiction for a command. EX_ENOGRP No such group The designated device or group name does not exist in the configuration file, or the network address for remote communication does not exist. EX_UNWCOD EX_CMDIOE Unknown function code Control command I/O error Detected a contradiction for a command. A read/write to the command device failed with an I/O error. Please confirm that the HORC Manager in the remote host is running, and then increase the value of the timeout in the configuration file. Contact the Hitachi Data Systems Support Center. Contact the Hitachi Data Systems Support Center. Verify the device or group name and add it to the configuration file of the remote and local hosts. Retry your operation after restart of the instance for CCI. Contact the Hitachi Data Systems Support Center if the operation fails because of same error again. Refer to the host syslog file, and investigate the cause of the error. If the problem persists, collect the log information of HORCM ($HORCM_LOG), and contact the Hitachi Data Systems Support Center Troubleshooting

293 Error code Error message Condition Recommended action Value EX_CMDRJE An order to the control/command device was rejected The request to the command device failed or was rejected. Note: This error code is sometimes caused by the operating system and reported as EX_CMDIOE instead of EX_CMDRJE (see next row). Verify TrueCopy/ ShadowImage functions are installed. Verify ports are set. Verify CU paths have been established. Verify that the target volume is available. CCI displays "SSB" in the output of the commands so a service representative can identify the cause of EX_CMDRJE (except for Tru64, DYNIX). 221 Example: # paircreate -g G1 -f never -vl -nocopy paircreate: [EX_CMDRJE] An order to the control/ command device was rejected Refer to the command log (/HORCM/log10/horcc_u1-1.log) for details. It was rejected due to SKEY=0x05, ASC=0x26, SSB=0xB9BF,0xB9C7 on Serial#(63502). EX_CMDIOE Control command I/O error or rejected A read/write to the command device failed with an I/O error or was rejected. Refer to the host syslog file, and investigate the cause of the error. If the cause is "Illegal Request (0x05)" Sense Key, please confirm the following items. 237 Verify TrueCopy/ ShadowImage functions are installed. Verify ports are set. Verify CU paths have been established. Verify that the target volume is available. If the problem persists, contact the Hitachi Data Systems Support Center. EX_ENQVOL Unmatched volume status within the group The volume attribute or the fence level within a group is not identical. Confirm status using the pairdisplay command. Make sure all volumes in the group have the same fence level and volume attributes. 236 Troubleshooting 9 11

294 Error code Error message Condition Recommended action Value EX_EVOLCE EX_EWSUSE EX_EWSTOT EX_EWSLTO EX_ESTMON EX_UNWCMD EX_INCSTG Pair Volume combination error Pair suspended at WAIT state Timeout waiting for specified status Timeout waiting for specified status on the local host HORCM Monitor stopped Unknown command Inconsistent status in group Combination of a volume is unsuitable between the remote and local host. Detected a suspended status (PSUE) for the paired volume, before it made it to the designated status. Detected a time out, before it made it to the designated status. Timeout error because the remote did not notify about expected status in time. HORC Manager monitoring was refused. An unknown command was attempted. The pair status of a volume within a group is not identical to the status of the other volumes in the group. EX_INVSTP Invalid pair status The pair status of the target volume is not appropriate. EX_INVVOL EX_INVMUN Invalid volume status Invalid mu# with HORC/UR or HOMRCF The volume status of the target volume is not appropriate. The MU# of the volume to be operated is not appropriate. Confirm volume status using the pairdisplay command, and change the combination of volumes properly. Please issue the pairresync command manually to the identified failed paired volume to try to recover it. If the problem persists, contact the Hitachi Data Systems Support Center. Please increase the value of the timeout using the -t option. For details, refer to the troubleshooting information in the relevant user document. Please confirm that HORC Manager on the remote host is running. Please confirm the value of "poll" in the configuration file. Please confirm the command name. Please confirm the pair status using the pairdisplay command. Please confirm the pair status using the pairdisplay command. Please confirm the volume status using the pairdisplay -l or the raidvchkdsp -v aou command. Please confirm the MU# (MU #1/2 cannot be used for TrueCopy and must be P-VOL for ShadowImage.) for the specified group using the pairdisplay command. And also confirm the command execution environment to be set as HOMRCF Troubleshooting

295 Error code Error message Condition Recommended action Value EX_ENLDEV No such LDEV within the RAID A device defined in the configuration file does not have a mapping to a real LUN and target ID within the RAID storage system. Please confirm that the Port, Target ID, LUN are defined correctly under HORCM_DEV in the configuration file. 227 EX_INVRCD Invalid return code Wrong return code. Contact the Hitachi Data Systems Support Center. 226 EX_VOLCUR S-VOL currency error Currency check error for S-VOL. Cannot guarantee identical data on S-VOL. Check the volume list to see if an operation was directed to the wrong S-VOL. 225 EX_VOLCUE Local volume currency error The volume specified with the SVOLtakeover command is not the same as the P- VOL. Please confirm the pair status of the local volume using the pairdisplay command. 224 EX_VOLCRE Local and remote volume currency error The combination of the volumes specified with Swap-takeover is unsuitable. Please confirm the pair status of remote and local volumes using the pairdisplay command. 223 EX_UNWERR Unknown error code. Wrong error code. Contact the Hitachi Data Systems Support Center. -- EX_ENOCTG Not enough CT groups in RAID When creating TrueCopy Async/UR or ShadowImage volume, CTGID could not be registered due to being beyond the max number of CT groups for an async volume: for VSP G1000, VSP, USP V/ VM, TagmaStore USP, TagmaStore NSC for HUS VM and 9900V for 7700E. Please create a pair with cutting the number of the group on the configuration files or make already existing group and the target group the same CTGID. Please confirm already existing group CTGID using the pairvolchk command. Then, please create a pair specifying CTGID as the paircreate -f option. 217 EX_EXTCTG Extended CT group across RAIDs A TrueCopy Async/UR or ShadowImage volume is defined in the configuration file (HORCM_CONF) as a group that extends across storage systems. Please confirm the serial # of the volumes by using the pairdisplay command to verify that the CT group is contained completely within one RAID storage system. 216 EX_ENXCTG No CT groups left for OPEN Vol use. An available CT group for OPEN Volume does not exist. Please confirm whether all CT groups are already used by mainframe volumes. 215 Troubleshooting 9 13

296 Error code Error message Condition Recommended action Value EX_ENQCTG Unmatched CTGID within the group The CT group references within a group do not have an identical CTGID. Please confirm the CTGID using the pairvolchk command and confirm that group references within the configuration file (HORCM_CONF) refer to the same CT group. 214 EX_ENPERM Permission denied with the LDEV A device mentioned in the configuration file does not have a permission for a pairoperation. Please confirm whether pairoperation is permitted on the device by using the pairdisplay or raidscan - find verify command. 213 EX_ENQSIZ Unmatched volume size for pairing Size of a volume is unsuitable between the remote and local volume. Please confirm volume size or number of LUSE volume using the 'raidscan -f' command, and make sure the volume sizes are identical. 212 EX_ERPERM Permission denied with the RAID A storage system (RAID) mentioned in the configuration file does not have a permission for CCI. Please confirm if the type of storage system is permitted for a CCI by using the inqraid -CLI and raidqry -h commands. 211 EX_ESVOLD SVOL denied due to be disabling A specified target volume for S-VOL is denied to become S- VOL by the setting of Data Retention Utility. Please confirm whether a target volume is setting to S- VOL disabling by using inqraid -fl or raidvchkscan -v gflag command. 209 EX_ENOSUP Microcode not supported The storage system does not support a function for CCI. Please confirm the microcode version by using the raidqry -l command. 210 EX_EPRORT Mode changes denied due to retention time A target volume is denied to be changing due to retention time via LDEV guarding. Please confirm the retention time for a target volume that is set to Data Retention Utility by using raidvchkscan -v gflag command. 208 EX_ESPERM Permission denied with the SLPR A specified command device does not have a permission to access other SLPR. Please make the SLPR so that the target port and the command device belongs to the same SLPR. 207 EX_ENOPOL Not enough Pool in RAID Could not retain the pool for executing a command due to be exceeded the threshold rate. Please release the pair of older generations paired volume, or re-synchronize the pair of split status paired volume Troubleshooting

297 Error code Error message Condition Recommended action Value EX_ENOOBJ EX_EPPERM EX_ENQCLP EX_CTXCHK EX_EACCES EX_ENAUTH No such Object in the RAID Permission denied with the privilege Unmatched CLPR with JNL and Volume Context check error Access denied with Lock/Unlock Authentication failed with User The specified object is not installed. There are port, LDEV, and Hostgroup in the object. The specified command device does not have an authority to execute this command. The specified command device does not have an authority to execute this command. An error is detected by the Context Checking. The resource that you specified to lock or unlock has already been used by another user. User authentication failed at the authentication command device. EW_INVARG Invalid argument Invalid option or an argument of the option. EW_INVOPA Invalid option argument Invalid argument of an option Specify the appropriate object. Check the status of one of the following. The specified port is not installed. The value of specified port is invalid. LU path is defined. A logical path between MCU and RCU remain. LDEV is not installed. The attribute of the port is not Target (TAR) or RCU Target (RCU). LUN security is invalid. The specified host group is not installed. Check the operation authentication. Check the operation authentication. Check if the operation by the command executes a proper procedures and has the consistency or not. Check if the specified resource is used by such as Device Manager - Storage Navigator or not. Check the user ID and password. User -h option to check the correct option, and specify it. Use -h option to check the correct option and use it. EW_INVOPT Invalid option Invalid option. Use -h option to check the correct option and use it Troubleshooting 9 15

298 Error code Error message Condition Recommended action Value EW_LNGARG EW_MAXARG Argument too long Maximum argument The number of character for action, object, option or argument of option exceeded the maximum. The total number of option or the argument of option exceeded the maximum. EW_ENFILE No such file The specified file dies not exist. EW_REQCMD EW_REQOPT EW_UNWCMD EW_UNWOPT Required action/ object list Required option list Unknown command raidcom: [EW_UNWOPT] Unknown option The number of action or the argument of object is insufficient. The number of option or the argument of option is insufficient. The command action or an object is undefined. Specifies an undefined option. EW_SYSERR System error An invalid internal error has detected. EW_ENOMEM Not enough core Memory to execute a command cannot be allocated in HORCM. EX_CHGOBJ Objects was changed while referring The object is in operation. Specify the number of characters of action, object, option, an argument of option, or the total number of characters are to be appropriate number of characters. Check the total number of option or argument of option. Check if the specified file exist or not, and specify the correct file. Use -h option and specify the correct action or object. Use -h option and specify the correct option. Check the issued command action and object. Use -h option and specify the correct option. Contact the Hitachi Data Systems Support Center. Add more virtual memory of a whole system, or terminate unnecessary programs or daemons that are executed in parallel. Issue the command again after the operation of the object is complete Generic error codes (horctakeover and pair commands) The following table lists the generic error codes returned by these commands: horctakeover paircurchk, paircreate, pairsplit, pairresync, pairevtwait, pairvolchk, pairsyncwait, pairdisplay In this table, "Unrecoverable" indicates errors that cannot be recovered by reexecuting the command, and "Recoverable" indicates errors that can be recoverable by reexecuting the command Troubleshooting

299 Table 9-3 Generic error codes (horctakeover and pair commands) Category Error code Error message Retur n Value Syntax for Argument (Unrecoverable) Configuration (Unrecoverable) Command I/O to RAID (Recoverable) Communication for HORCM (Recoverable) EX_REQARG Required Arg list 254 EX_INVARG Invalid argument 253 EX_INVNAM Invalid name of option 249 EX_UNWOPT Unknown option 252 EX_UNWCOD Unknown function code 238 EX_UNWCMD Unknown command 230 EX_ERANGE Result too large 244 EX_ENAMLG File name too long 243 EX_INVRCD Invalid return code 226 EX_ENOGRP No such group 239 EX_ENOENT No such device or group 247 EX_ENODEV No such device 246 EX_ENLDEV No such LDEV within the RAID 227 EX_ENOUNT No such RAID unit 219 EX_INVMUN Invalid mu# with HORC or HOMRCF 220 EX_ENQSER Unmatched Serial# vs RAID unitid 218 EX_EXTCTG Extended CTgroup across RAIDs 216 EX_ENQCTG Unmatched CTGID within the group 214 EX_ENPERM Permission denied with the LDEV 213 EX_ERPERM Permission denied with the RAID 211 EX_ESPERM Permission denied with the SLPR 207 EX_CMDRJE An order to the control/command was rejected 221 EX_CMDIOE Control command I/O error, or rejected 237 EX_OPTINV A specified option is invalid 248 EX_INVMOD Invalid RAID command mode 241 EX_INVCMD Invalid RAID command 240 EX_ATTHOR Cannot be attached to HORC manager 251 EX_ATTDBG Cannot be attached to a Debug layer 250 EX_COMERR Cannot be communicate with HORC manager 255 Recoverable EX_ENORMT No remote host alive for remote commands, or Remote CCI might be blocked (sleeping) on an existing I/O. Resource (Unrecoverable) Generic error codes (raidscan, raidqry, raidar, horcctl) The following table lists the generic error codes returned by these commands: 242 EX_ENOMEM Not enough core 245 Troubleshooting 9 17

300 raidscan raidqry raidar horcctl In this table, "Unrecoverable" indicates errors that cannot be recovered by reexecuting the command, and "Recoverable" indicates errors that can be recoverable by reexecuting the command. Table 9-4 Generic error codes (raidscan, raidqry, raidar, horcctl) Category Error code Error message Value Syntax for Argument (Unrecoverable) Configuration (Unrecoverable) Command I/O to RAID (Recoverable) Communication for HORCM (Recoverable) Resource (Unrecoverable) EX_REQARG Required Arg list 254 EX_INVARG Invalid argument 253 EX_INVNAM Invalid name of option 249 EX_UNWOPT Unknown option 252 EX_UNWCOD Unknown function code 238 EX_UNWCMD Unknown command 230 EX_ERANGE Result too large 244 EX_ENAMLG File name too long 243 EX_INVRCD Invalid return code 226 EX_ENLDEV No such LDEV within the RAID 227 EX_ENOUNT No such RAID unit 219 EX_INVMUN Invalid mu# with HORC or HOMRCF 220 EX_ERPERM Permission denied with the RAID 211 EX_ENOSUP Microcode not supported 210 EX_ESPERM Permission denied with the SLPR 207 EX_CMDIOE Control command I/O error 237 EX_OPTINV A specified option is invalid 248 EX_INVMOD Invalid RAID command mode 241 EX_INVCMD Invalid RAID command 240 EX_ATTHOR Can't be attached to HORC manager 251 EX_ATTDBG Can't be attached to a Debug layer 250 EX_COMERR Can't be communicated with HORC manager 255 EX_ENOMEM Not enough core 245 Specific error codes The following table lists the specific error codes returned by these commands: horctakeover paircurchk, paircreate, pairsplit, pairresync, pairevtwait, pairvolchk, pairsyncwait, raidvchkset 9 18 Troubleshooting

301 In this table, "Unrecoverable" indicates errors that cannot be recovered by reexecuting the command, and "Recoverable" indicates errors that can be recoverable by reexecuting the command. See the Command Control Interface Command Reference for more information on error codes for each command. Table 9-5 Specific error codes Category Error code Error message Value Volume (Unrecoverable) Timer (Recoverable) Resource (Unrecoverable) EX_ENQVOL Unmatched volume status within the group 236 EX_INCSTG Inconsistent status in group 229 EX_INVVOL Invalid volume status 222 EX_EVOLCE Pair Volume combination error 235 EX_INVSTP Invalid pair status 228 EX_VOLCUR S-VOL currency error 225 EX_VOLCUE Local Volume currency error 224 EX_VOLCRE Local and Remote Volume currency error 223 EX_EWSUSE Pair suspended at WAIT state 234 EX_ENQSIZ Unmatched volume size for pairing 212 EX_ESVOLD SVOL denied due to be disabling 209 EX_EPRORT Mode changes denied due to retention time 208 EX_EWSTOT Timeout waiting for specified status 233 EX_EWSLTO Timeout waiting for specified status on the local 232 host EX_ENOCTG Not enough CT groups in the RAID 217 EX_ENXCTG No CT groups left for OPEN Vol use. 215 EX_ENOPOL Not enough Pool in RAID 206 SSB codes An SSB code is error information that is output when an error occurs by executing a CCI command. The SSB code is output to the CCI execution log file or to the console. Identify the SSB code from an error code as follows: SSB code that is output to the CCI execution log file. The following shows an example of a SSB code that is output to the CCI execution log file. Example:11:06: SSB = 0xb9a0,2089 The alphanumeric characters after the equal sign shows an error code. The last four digits of alphanumeric characters on the left side of the comma (,) is SSB1 (for example, b9ao), and the alphanumeric characters on the right side is SSB2 (for example, 2089). SSB code that is output on the console. The following shows an example of an SSB code that is output to the console. Troubleshooting 9 19

302 Figure 9-1 An example of SSB code that is output to the console The alphanumeric characters after the "SSB=" show an error code. The last four digits of alphanumeric characters on the left side of comma (,) is SSB1 (for example, B9E1), and the last four digits of alphanumeric characters on the right side is SSB2 (for example, B901). The following describes the SSB codes that are returned by the replication commands and the configuration setting command (raidcom). SSB codes returned by the replication commands When a replication command returns an SSB code, refer to the troubleshooting information in the user document for the product as follows: Command Product returning the SSB code paircreate pairresync pairsplit horctakeover horctakeoff paircreate pairresync pairsplit horctakeover horctakeoff paircreate pairresync pairsplit raidvchkset -vt raidvchkset -vs Hitachi TrueCopy Universal Replicator Hitachi ShadowImage Database Validator raidvchkset -vg Data Retention Utility raidvchkset -vext Hitachi Dynamic Provisioning SSB codes returned by the configuration setting command (raidcom) Executing the configuration setting command (raidcom command) may return an SSB code. An error may occur whether the command is executed synchronously or asynchronously. For an asynchronous error, the error information is displayed on the console by executing raidcom get command_status command. When the error message shows "CMDRJE" or " ", check the contents of SSB1 and SSB2. You can 9 20 Troubleshooting

303 verify a content of an error by the raidcom get error_message command. When you specify the SSB code with the raidcom get error_message command, make sure not to specify a wrong SSB code. The following tables provide information about each SSB code returned by the configuration setting command (raidcom command). If you see an error not described in the tables, contact the Hitachi Data Systems Support Center. Table 9-6 SSB codes returned by the configuration setting command (common) common Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing/ Async 2E Unavailable to operate because another application is in progress on Device Manager - Storage Navigator or SVP. CMDRJE Executing 2E The resource group to which the operation object belongs is locked by the other user. CMDRJE Executing 2E The command cannot be executed because there is blocked part in the system. CMDRJE Executing 2E The command cannot be executed because the user authentication is not performed. CMDRJE Executing 2EF The virtual storage machine with the specified serial number was not found. Table 9-7 SSB codes returned by raidcom add external_grp raidcom add external_grp Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E00 000D Invalid emulation type. Async 2E There are not enough cache management devices. CMDRJE Executing 2E The external volume group is not in a effective range. Async 2E The external volume group exists already. Async 2E00 410B The specified CLPR does not exist. CMDRJE Executing 2E00 410D The volume cannot be mapped for online data migration because the emulation type is not OPEN-V. CMDRJE Executing 2E00 410E Invalid attribute of the specified external volume group. CMDRJE Executing 2E The path group is not in a effective range. CMDRJE Executing 2E The value of specified port is not enabled. Troubleshooting 9 21

304 raidcom add external_grp Error message Executing / Async Error code SSB1 SSB2 Description Async 2E LUN of specified external storage port does not exist. Async 2E The external volume cannot be created because the specified external LU is a command device. Async 2E The WWN on the side of specified external storage does not connected to a External port. This message may be output if the migration source storage system is USP V/VM and the host mode option 2 is not set to the port that connects to the migration target storage system. Async 2E The specified external LU cannot create a external volume because the transition of data is required. Async 2E The specified path group cannot be operated because a path between other devices exists. CMDRJE Executing 2E The storage system is in internal process, or the configuration changing processes are conflicting. CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command. CMDRJE CMDRJE Async 2E Package for Mainframe is required when you specify the emulation type of mainframe. Async 2E The specified MP Blade is not installed. Executing/ Async Executing Async 2E The program product of Universal Volume Manager is not installed. 2E The program product of nondisruptive migration is not installed. Async 2E The external volume group exists already. CMDRJE Executing 2E The external volume group exists already. Async 2E Exceeded the number of mapping that can be set per 1 port. Async 2E The operation cannot be done because the number of path in the path group exceeds 8. Async 2E The external volume cannot be added because the number of virtual volumes that can be created in the system exceeded the maximum number. Async 2E The specified external LU has mapped already. CMDRJE Executing 2E The port attribute is not External. Async 2E The specified external storage LU is the device of not supported Troubleshooting

305 raidcom add external_grp Error message Executing / Async Error code SSB1 SSB2 Description Async 2E The specified external storage system is not supported. Async 2E The specified external volume does not support nondisruptive migration. Async 2E The usage capacity exceeds the license capacity of the program product. CMDRJE Executing 2EDA 00EE The command cannot be accepted. After a while, execute the same command. Async 2EDA 41FA An internal error occurred. CMDRJE Executing 2EF The specified parameter is invalid. Check the Command Control Interface Command Reference. Table 9-8 SSB codes returned by raidcom check_ext_storage external_grp raidcom check_ext_storage external_grp Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The external volume group is not in the effective range. CMDRJE Executing 2E The specified external volume has already disconnected the path, or is in the process of checking path. CMDRJE Executing 2E11 001B The target LDEV is blocked. CMDRJE Executing 2E The path for the specified external path is in the state of disconnected. CMDRJE Executing 2E All the paths for the specified external path are blocked. CMDRJE Executing 2E There is no external volume group. CMDRJE Executing 2E There is no external path. CMDRJE Executing 2E30 001E Online from the mainframe host. Async 2EDA 0905 An internal error occurred by the operation of external path. Call Hitachi Data Systems Support Center. CMDRJE Executing 2EDA 0905 An internal error occurred by the operation of external volume. Call Hitachi Data Systems Support Center. Troubleshooting 9 23

306 Table 9-9 SSB codes returned by raidcom delete external_grp raidcom delete external_grp Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The external volume group # is in the effective range. Async 2E LDEVs in the external volume group are devices that have a CC/XRC attributes. CMDRJE Executing 2E The specified external volume group is used in another operation. Async 2E Destage is not executed. Async 2E The external volume is used as Compatible FlashCopy V2. Async 2E The specified external volume cannot be deleted because audit logs for the system disk are being used. Async 2E The operation cannot be done because the internal processing is in progress. CMDRJE Executing 2E The storage system is in internal process, or the configuration changing processes are conflicting. Async 2E The operation cannot be done because there is blocked part in the system. CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command. CMDRJE Executing 2E There is no external volume group. CMDRJE Executing 2E LU path is defined to LDEV in the external volume group. Async 2E The external volume is used as a system disk. Async 2E The external volume is used as LUSE. Async 2E The external volume is used as a TrueCopy pair volume. Async 2E The external volume is used as a TrueCopy pair volume. Async 2E The external volume is used as a ShadowImage pair volume. Async 2E The external volume is used as a ShadowImage pair volume. Async 2E There is the volume that has path definition. Async 2E The external volume is used as a ShadowImage reserved VOL. Async 2E The external volume is used as a Volume Migration reserved VOL Troubleshooting

307 raidcom delete external_grp Error message Executing / Async Error code SSB1 SSB2 Description Async 2E There is a mainframe path group setting in the external volume. Async 2E30 410A There is a Data Retention Utility setting in the external volume. Async 2E30 410B There is a mainframe LDEV Guard setting in the external volume. Async 2E30 410C There is a Volume Security setting in the external volume. Async 2E30 410D The external volume is used as a Universal Replicator pair volume. Async 2E30 410E The external volume is used as a Universal Replicator journal volume. Async 2E30 410F The external volume is used as a pool-vol. Async 2E The external volume is used as a pool-vol. Async 2E The external volume is used as a Volume Migration VOL. Async 2E The external volume is used as a Volume Migration VOL. Async 2E The target external group cannot be deleted because a quorum disk exists in it. CMDRJE Executing 2EDA 00EE The command cannot be accepted. After a while, execute the same command. Async 2EE8 FFFB An internal error occurred. Call Hitachi Data Systems Support Center. Async 2EFF 41FF An internal error occurred. Call Hitachi Data Systems Support Center. Table 9-10 SSB codes returned by raidcom check_ext_storage path raidcom check_ext_storage path Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The path group is not in the enabled range. CMDRJE Executing 2E The value of the port is not enabled. Async 2E The specified external volume has already disconnected the path, or is in the process of checking path. Async 2E11 001B The target LDEV is blocked. Async 2E The path for the specified external path is in the state of disconnected. Troubleshooting 9 25

308 raidcom check_ext_storage path Error message Executing / Async Error code SSB1 SSB2 Description Async 2E All the paths for the specified external path are blocked. CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command. Async 2E There is no specified external volume. CMDRJE Async/ Executing 2E There is no specified path. CMDRJE Executing 2E WWN is not registered. CMDRJE Executing 2E The path group is not registered. CMDRJE Executing 2E The path group does not exist. Async 2E30 001E Online from the mainframe host. CMDRJE Executing 2E The port attribute is not External (ELUN). CMDRJE Executing 2EDA 00EE The command cannot be accepted. After a while, execute the same command. Async 2EDA 0905 An internal error occurred by the operation of external path. Call Hitachi Data Systems Support Center. Table 9-11 SSB codes that are returned by raidcom disconnect external_grp command raidcom disconnect external_grp Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The external volume group is not in the effective range. CMDRJE Executing 2E The specified LDEV is used as a ShadowImage pair. CMDRJE Executing 2E It is used as a TrueCopy or Universal Replicator pair. CMDRJE Executing 2E A ShadowImage pair, a Thin Image/Copy-on- Write Snapshot pair or a Compatible FlashCopy V2 relationship or in status of splitting or pending exists. CMDRJE Executing 2E The specified LDEV is used as a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E It is used as a system disk. CMDRJE Executing 2E It is used as a concurrent copy or a XRC Troubleshooting

309 raidcom disconnect external_grp Error message Executing / Async Error code SSB1 SSB2 Description Async 2E The specified LDEV is used as the primary volume of a global-active device (GAD) pair. Async 2E The specified LDEV is used as the secondary volume of a GAD pair. CMDRJE Executing 2E The specified external volume group is in the state of disconnected. CMDRJE Executing 2E The specified external device is in the state of disconnected. CMDRJE Executing 2E The specified external volume has already disconnected the path, or is in the process of checking path. CMDRJE Executing 2E It is in the state of shredding. CMDRJE Executing 2E11 001B The target LDEV is blocked. CMDRJE Executing 2E The path for the specified external path is in the state of disconnected. CMDRJE Executing 2E All the paths for the specified external path are blocked. CMDRJE Executing 2E The specified external volume belongs to a Thin Image or Copy-on-Write Snapshot where the pair in the PSUS status exists. CMDRJE Executing 2E11 800E The operation cannot be done because the internal processing is in progress. Wait for a while, then retry the operation. CMDRJE Executing 2E There is no specified external volume. CMDRJE Executing 2E There is no specified path. CMDRJE Executing 2E30 000A It is included the Hitachi Dynamic Provisioning volume that is associated with a pool. Async 2E30 000C The specified LDEV is used as a quorum disk. CMDRJE Executing 2E30 000E It is used as a pool volume. CMDRJE Executing 2E30 000F It is used as a journal volume. CMDRJE Executing 2E It is used as a reserved volume of Volume Migration. CMDRJE Executing 2E30 001A Volume Security is set. CMDRJE Executing 2E30 001C It is used as a remote command device. CMDRJE Executing 2E30 001E Online from the mainframe host. CMDRJE Executing 2E30 004E This is a volume that the Data Retention Utility is set. CMDRJE Executing 2E The Dynamic Provisioning volume not in the blocked state is included in the Dynamic Provisioning that is associated with the pool to which the pool volume is belongs. Troubleshooting 9 27

310 raidcom disconnect external_grp Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2EDA 0000 An internal error occurred by the operation of disconnecting the external volume. Call Hitachi Data Systems Support Center. CMDRJE Executing 2EDA 0905 An internal error occurred by the operation of external volume. Call Hitachi Data Systems Support Center. Table 9-12 SSB codes that are returned by raidcom modify external_grp command raidcom modify external_grp Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The external volume group is not in the effective range. CMDRJE Executing 2E00 410F The specified value of the load balance mode is invalid. CMDRJE Executing 2E The specified value of the ALUA mode is invalid. CMDRJE Executing 2E MP Blade ID is not in the effective range. CMDRJE Executing 2E The operation cannot be performed because the volume used for data migration is reserved from the host. CMDRJE Executing 2E The specified MP Blade is blocked. CMDRJE Executing 2E The attribute cannot be changed because Volume Migration is being executed. CMDRJE Executing 2E The load balance mode cannot be changed because the alternative path mode is set to Single. CMDRJE Executing 2E11 800F The load balance mode cannot be changed because microcodes of multiple versions are in the storage system. CMDRJE Executing 2E There is no external volume group. CMDRJE Executing 2E The specified MP Blade is not installed. CMDRJE Executing 2E The attribute cannot be changed because the external volume is used as a ShadowImage pair volume. CMDRJE Executing 2E30 410D The external volume is used as a Universal Replicator pair volume. CMDRJE Executing 2E30 411A The external volume is used as a TrueCopy volume. CMDRJE Executing 2E31 000C Cache mode cannot be changed because there is an LDEV that Cache Residency Manager bind mode is set Troubleshooting

311 raidcom modify external_grp Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E Cache mode cannot be changed because the specified external volume includes a pool volume or an LDEV that is used by LUSE. CMDRJE Executing 2E The cache mode cannot be changed because one of the following applies to the specified external volume. A pool volume of the pool that consists of both external volumes and internal volumes. A pool volume of the pool where the multi tier pool option is enabled. CMDRJE Executing 2E The attribute of the external volume cannot be changed from the current cache mode to the specified cache mode. CMDRJE Executing 2E The attribute cannot be changed because the external volume group is not mapped for online data migration. CMDRJE Executing 2EDA 00F1 The specified command cannot be accepted because the command is not supported. CMDRJE Executing 2EDA 0905 An internal error occurred on the changing of an external volume option. Call Hitachi Data Systems Support Center. CMDRJE Executing 2EF The specified parameter is incorrect. Check the Command Control Interface Command Reference. Table 9-13 SSB codes that are returned by raidcom modify port -loop_id command raidcom modify port -loop_id Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B C The specified AL-PA is invalid. CMDRJE Executing B E The specified topology is invalid. CMDRJE Executing B955 05A6 The other than "fabric on" cannot be specified when specifying a topology of the package for Fibre Channel over Ethernet. CMDRJE Executing B955 05A7 The other than "P-to-P (point to point)" cannot be specified when specifying a topology of the package for Fibre Channel over Ethernet. CMDRJE Executing B The command device being used at the local CCI exists under the port. CMDRJE Executing B F The program product is not installed. CMDRJE Executing B D Invalid host speed is set for the 4Gbps fibre adapter. The available host speeds are AUTO, 1G, 2G, and 4G only. Troubleshooting 9 29

312 raidcom modify port -loop_id Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B F Invalid host speed is set for the 8Gbps fibre adapter. The available host speeds are AUTO, 2G, 4G, and 8G only. CMDRJE Executing B955 11A5 The other than "10G" cannot be specified when specifying a host speed of the package for Fibre Channel over Ethernet. Table 9-14 SSB codes that are returned by raidcom modify port -topology command raidcom modify port -topology Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B C The specified AL-PA is invalid. CMDRJE Executing B E The specified topology is invalid. CMDRJE Executing B955 05A6 The other than "fabric on" cannot be specified when specifying a topology of the package for Fibre Channel over Ethernet. CMDRJE Executing B955 05A7 The other than "P-to-P (point to point)" cannot be specified when specifying a topology of the package for Fibre Channel over Ethernet. CMDRJE Executing B The command device being used at the local CCI exists under the port. CMDRJE Executing B F The program product is not installed. CMDRJE Executing B D Invalid host speed is set for the 4Gbps fibre adapter. The available host speeds are AUTO, 1G, 2G, and 4G only. CMDRJE Executing B F Invalid host speed is set for the 8Gbps fibre adapter. The available host speeds are AUTO, 2G, 4G, and 8G only. CMDRJE Executing B955 11A5 The other than "10G" cannot be specified when specifying a host speed of the package for Fibre Channel over Ethernet. CMDRJE Executing B955 12AF Topology FC-AL and 16G as the host speed is not supported for the 16Gbps fibre adapter. Table 9-15 SSB codes that are returned by raidcom modify port -security _switch command raidcom modify port -security _switch Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B C The specified AL-PA is invalid. CMDRJE Executing B E The specified topology is invalid Troubleshooting

313 raidcom modify port -security _switch Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B955 05A6 The other than "fabric on" cannot be specified when specifying a topology of the package for Fibre Channel over Ethernet. CMDRJE Executing B955 05A7 The other than "P-to-P (point to point)" cannot be specified when specifying a topology of the package for Fibre Channel over Ethernet. CMDRJE Executing B The command device being used at the local CCI exists under the port. CMDRJE Executing B F The program product is not installed. CMDRJE Executing B D Invalid host speed is set for the 4Gbps fibre adapter. The available host speeds are AUTO, 1G, 2G, and 4G only. CMDRJE Executing B F Invalid host speed is set for the 8Gbps fibre adapter. The available host speeds are AUTO, 2G, 4G, and 8G only. CMDRJE Executing B955 11A5 The other than "10G" cannot be specified when specifying a host speed of the package for Fibre Channel over Ethernet. Table 9-16 SSB codes that are returned by raidcom add ldev command raidcom add ldev Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E It exceeds the range of LDEV number. CMDRJE Executing 2E Cannot create because the specified capacity is invalid. CMDRJE Executing 2E SSID is not in the effective range. CMDRJE Executing 2E00 000D The value of specified emulation type is invalid. CMDRJE Executing 2E00 000E The specified emulation type is not supported in this command. CMDRJE Executing 2E A Dynamic Provisioning virtual volume cannot be created because the specified LDEV number is already used. Asynchrono us Asynchrono us 2E There are not enough cache management devices. 2E Cannot create because the specified capacity is invalid. CMDRJE Executing 2E The capacity in the case of specifying a emulation type of the mainframe series must be dividable by the cylinder. CMDRJE Executing 2E00 001A The capacity when 3390-V emulation type is specified must be divisible by page unit. Troubleshooting 9 31

314 raidcom add ldev Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E00 001C When you specify emulation type for open system, you cannot specify the size by the cylinder. CMDRJE Executing Async 2E A volume for online data migration cannot be created because the specified value of capacity (LBA) is not the maximum. CMDRJE Executing 2E The capacity must be specified because LDEVs are in the parity group (or the external volume group). CMDRJE Executing 2E The capacity must be specified. Async 2E00 002D The emulation type of the mainframe cannot be specified because the virtual volume is set for the specified LDEV. CMDRJE Executing 2E The parity group number or the external group number is not in the effective range. Async 2E Failed to restore the LDEV that is created to external volume group. CMDRJE Executing 2E The specified pool ID is not in the effective range. Asynchrono us 2E The total capacity of Dynamic Provisioning V-VOL which is defined in the specified pool exceeds the permitted capacity in the pool. CMDRJE Executing 2E The specified CLPR number is not in the effective range. CMDRJE Executing 2E MP Blade ID is not in the effective range. CMDRJE Executing 2E The specified LDEV is used as a Compatible FlashCopy V2 relationship. Async 2E10 001F The operation cannot be done because the total capacity of virtual volumes for Dynamic Tiering in the system exceeds the maximum. Async 2E10 005A The operation cannot be performed because the following information of the migration source and the migration target does not match. serial number product ID emulation type SSID LUSE CVS configuration LDEV number Async 2E The volumes cannot be added because the encryption value of the key number that is set to encryption ECC is invalid. Async 2E The volumes cannot be added because the check sum of the encryption key is not coincident Troubleshooting

315 raidcom add ldev Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing /Async 2E The specified pool be associated with the virtual volume of Dynamic Provisioning because the state of the pool is incorrect. Async 2E An LDEV that is in the state of shredding is included in the parity group of the target LDEV. Async 2E An LDEV that is in the state of formatting is included in the parity group of the target LDEV. Async 2E An LDEV that is in the state of executing quick format is included in the parity group of the target LDEV. CMDRJE Executing 2E The specified LDEV is used in another operation. Async 2E The parity group of the target LDEV is in the state of correction copy. CMDRJE Executing 2E The parity group or the external volume group that the specified LDEV is belongs to is used in another operation. Async 2E The operation cannot be done because the internal processing is in progress. CMDRJE Executing 2E The storage system is in internal process, or the configuration changing processes are conflicting. Async 2E Cache segment size is incorrect. Async 2E The operation cannot be done because there is blocked part in the system. CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command. CMDRJE Executing/ Async 2E The specified CLPR does not exist. CMDRJE Executing 2E There is no parity group. CMDRJE Executing/ Async 2E Pool ID is invalid. Async 2E The specified MP Blade is not installed. Asynchrono us Asynchrono us 2E There is not enough free shared memory space. 2E Package for Mainframe is required when you specify the emulation type of mainframe. CMDRJE Executing 2E The program product is not installed. CMDRJE Executing 2E The program product is not installed. CMDRJE/Get Command Executing/ Async 2E The program product is not installed. Troubleshooting 9 33

316 raidcom add ldev Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E21 900E Compatible Software for IBM FlashCopy SE program product is not installed. CMDRJE Executing 2E LDEV is already defined. CMDRJE Executing 2E22 000F You cannot create the volume because the size of the specified external volume group exceeds the maximum capacity of the external volume for online data migration. CMDRJE Executing/ 2E The number exceeds the maximum number of Async LDEV that can be created in the current system configuration. Async 2E The specified LDEV is used in the FICON Data Migration. CMDRJE Executing 2E The specified SSID is already used in another CU. CMDRJE Executing 2E The SSID is allocated to the CU already. Asynchrono us 2E The specified volume is used as an alias device in Compatible PAV. Async 2E An LDEV of another emulation type is allocated in the range where the number is divided into each 32LDEVs. CMDRJE Executing 2E30 004C The emulation type that cannot be mixed with is specified. CMDRJE Executing 2E30 004D The number of ldevs exceeds the maximum number of ldevs that can be created in the parity group or the external volume group. CMDRJE Executing 2E There is not enough amount of free space that is specified in the parity group or the external volume group. CMDRJE Executing 2E The location is out of the range that can be specified. CMDRJE Executing 2E Volume whose emulation type is 3390-V cannot be created in RAID1 parity group. CMDRJE CMDRJE Executing/ Async Executing/ Async 2E The virtual volume cannot be added because the number of virtual volumes that can be created in the system exceeded the maximum number. 2E The specified pool is the pool for Thin Image or Copy-on-Write Snapshot. CMDRJE Executing 2E A virtual volume of Dynamic Provisioning that is associated with the specified pool cannot be created with the specified emulation type Troubleshooting

317 raidcom add ldev Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E TSE-VOL cannot be created because of the following conditions. The specified pool is other than HDPz pool. The specified emulation type is other than 3390-A. CMDRJE Executing 2E TSE-VOL cannot be created in combination with the specified pool ID and the CU number of LDEV. You must specify the even CU number for the pool of even pool ID, and the odd CU number for the pool of odd pool ID. Async 2E A TSE-VOL cannot be created in the specified pool for Dynamic Tiering. CMDRJE Executing 2EE8 00EE The command cannot be accepted. After a while, execute the same command. Async 2EE8 FFFB An internal error occurred. Call Hitachi Data Systems Support Center. CMDRJE Executing 2EF The specified parameter is invalid. Check the Command Control Interface Command Reference. ERANGE Result too large Executing - - The value of the capacity is invalid. Table 9-17 SSB codes that are returned by raidcom delete journal command raidcom delete journal Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The number of specified LDEV is invalid. Async 2E The specified volume capacity is too small. CMDRJE Executing 2E The specified journal ID is exceeds the range. Async 2E The specified volume is not installed or cannot be used. Async 2E The specified volume is used in maintenance operation. Async 2E The specified operation failed because the journal or mirror is not in the operable status. Async 2E The journal volume cannot be deleted with the specified journal status. Async 2E11 800B The operation cannot be done because it is in the state of start-up. Async 2E11 800E The operation cannot be done because the internal processing is in progress. Wait for a while, then retry the operation. Troubleshooting 9 35

318 raidcom delete journal Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command. CMDRJE Executing 2E The specified LDEV is not in the journal. CMDRJE Executing 2E The specified journal ID is not registered. Async 2E The operation failed because the specified journal is not registered. Async 2E The journal volume cannot be added, or the journal cannot be added to the extended CT group due to insufficient capacity of the shared memory (SM). CMDRJE Executing 2E SM for Universal Replicator is not installed. CMDRJE Executing 2E The number of specified LDEVs is invalid. Async 2E The specified volume cannot be used as a journal volume because it is an external volume that can execute the I/O suppression mode. Async 2E The specified journal cannot be deleted because there are data volumes. CMDRJE Executing 2EE4 08E6 The command cannot be accepted. After a while, execute the same command. Async 2EE4 50EE An internal error occurred. Call Hitachi Data Systems Support Center. Table 9-18 SSB codes that are returned by raidcom add journal command raidcom add journal Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The value of LDEV number is invalid. CMDRJE Executing 2E A new journal volume cannot be registered because the number of journal volume exceeds the maximum that can be registered. Async 2E The specified volume capacity is too small. CMDRJE Executing 2E The specified MP Blade ID is invalid. CMDRJE Executing Async 2E The specified volume is already used by another program product. CMDRJE Executing Async 2E The specified volume is not installed or cannot be used. Async 2E10 001A The specified volume is connected from the mainframe host Troubleshooting

319 raidcom add journal Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE CMDRJE CMDRJE Executing Async Executing Async 2E10 001B There is a PIN slot in the journal volume. 2E10 001C The specified volume cannot be registered as a journal volume because it is in shredding. Wait until the shredding operation is completed, then retry the operation. Async 2E The specified volume is used in maintenance operation. Async 2E The specified volume cannot be used as the journal volume because the virtual LDEV ID is deleted. Async 2E The specified volume cannot be used as the journal volume because it is the virtual volume. Async 2E The specified operation failed because the journal or mirror is not in the operable status. Async 2E11 800B The operation cannot be done because it is in the state of start-up. Async 2E11 800E The operation cannot be done because the internal processing is in progress. Wait for a while, then retry the operation. Executing Async 2E11 810A Abnormal cache status. CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command. CMDRJE Executing 2E The specified LDEV is not defined. CMDRJE Executing 2E The specified MP Blade is not installed. Async 2E The operation failed because the specified journal is not installed. Async 2E The journal volume cannot be added, or the journal cannot be added to the extended CT group due to insufficient capacity of the shared memory (SM). CMDRJE Executing 2E The SM for Universal Replicator is not installed. Async 2E A journal volume cannot be registered, or a journal cannot be added to the extended CT group because the program product of Universal Replicator or Universal Replicator for Mainframe is not installed. Async 2E A new journal volume cannot be registered, or the number of selected volumes is too many. CMDRJE Executing 2E The number of specified LDEVs is invalid. Async 2E23 003E The operation failed because the multiple LDKC numbers cannot be mixed in the journal. Troubleshooting 9 37

320 raidcom add journal Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE CMDRJE CMDRJE CMDRJE CMDRJE CMDRJE CMDRJE CMDRJE CMDRJE CMDRJE Async 2E The operation failed because the number of journals in the journal or the extended CT group exceeds the maximum. Executing Async Executing Async Executing Async Executing Async Executing Async 2E The specified volume cannot be used as a journal volume because it is set by Cache Residency Manager or Cache Residency Manager for Mainframe. 2E The specified volume cannot be used because it is used in FICON(R) Data Migration. 2E A path is defined in the specified volume. 2E30 000C The operation failed because the specified volume is a Quorum disk. 2E30 000D The specified volume cannot be used as a journal volume because it is a system disk. Async 2E30 000E The operation failed because the specified volume is a pool volume of Dynamic Provisioning. Async/ Executing Executing Async Executing Async Executing Async Executing Async 2E30 000F The specified volume is already used as a journal volume or a data volume. 2E The specified volume is used as a command device. 2E The specified volume cannot be used as a journal volume because it is a LUSE volume. 2E The specified volume cannot be used as a journal volume because it is set by Data Retention Utility or Volume Retention Manager. 2E30 001A Using the specified volume is prohibited by Volume Security. CMDRJE Executing 2E The internal volumes and external volumes exist in the specified journal. Async 2E The emulation type of the specified volume is not supported. Or, the combination of an emulation type of the journal volume is incorrect Troubleshooting

321 raidcom add journal Error message Executing / Async Error code SSB1 SSB2 Description Async 2E The volume cannot be registered as a journal volume because the CLPR number of the specified volume differs from the CLPR number of the registered journal volume. CMDRJE Executing 2E30 005F The specified LDEV is a remote command device. CMDRJE Executing 2E The specified volume cannot be used as a journal Async volume because it is an external volume that can execute the I/O suppression mode. CMDRJE CMDRJE CMDRJE CMDRJE CMDRJE CMDRJE Executing Async Executing Async Executing Async 2E The specified volume is a reserved volume of a mainframe host. 2E The specified volume is used by the XRC. 2E The specified volume is a volume of Just in Time (On-demand) function. Async 2E The specified volume cannot be used as a journal volume because it is used by Compatible PAV. Executing Async Executing Async 2E The resource group ID of the specified volume cannot be registered because the resource group ID is different from the resource group ID of the other journal volume in the specified journal group. 2E The specified LDEV cannot be operated because it is an external volume mapped for online data migration. Async 2E The specified LDEV cannot be used as a journal volume because the size of the LDEV is less than the minimum capacity of journal volume. Executing Async 2E The operation cannot be performed because the specified volume is not the Dynamic Provisioning V-VOL. CMDRJE Executing 2EE4 08E6 The command cannot be accepted. After a while, execute the same command. CMDRJE Executing Async 2EE4 50EE An internal error occurred. Call Hitachi Data Systems Support Center. CMDRJE Executing Async 2EE4 FEEC An internal error occurred. Call Hitachi Data Systems Support Center. CMDRJE Executing 2EF The specified parameter is invalid. Check the Command Control Interface Command Reference. Troubleshooting 9 39

322 Table 9-19 SSB codes that are returned by raidcom modify journal command raidcom modify journal Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The specified volume capacity is too small. CMDRJE Executing 2E00 500B The specified path block watch time exceeds the range. CMDRJE Executing 2E The specified MP Blade ID is invalid. CMDRJE Executing 2E The specified volume is not installed or cannot be used. CMDRJE Executing 2E The specified operation failed because the journal or mirror is not in the operable status. CMDRJE Executing 2E The specified operation failed because the mirror of journal is not in the operable status. CMDRJE Executing 2E The specified MP Blade is blocked. CMDRJE Executing 2E11 800B The operation cannot be done because it is in the state of start-up. CMDRJE Executing 2E The specified journal ID is not registered. CMDRJE Executing 2E The operation failed because the specified journal is not registered. CMDRJE Executing 2E The journal volume cannot be added, or the journal cannot be added to the extended CT group due to insufficient capacity of the shared memory (SM). Async 2E The specified volume cannot be used as a journal volume because it is an external volume that can execute the I/O suppression mode. CMDRJE Executing 2E The timer type cannot be changed because the specified journal belongs to the extended CT group. CMDRJE Executing 2E The parameter of inflow control cannot be changed because the specified journal is not a primary journal. CMDRJE Executing 2E The cache mode option or the data overflow monitoring time cannot be changed because the specified journal is used by both the primary and the secondary journals. CMDRJE Executing 2EE4 50EE An internal error occurred. Call Hitachi Data Systems Support Center Troubleshooting

323 Table 9-20 SSB codes that are returned by raidcom modify ldev -mp_blade_id command raidcom modify ldev -mp_blade_id Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The number of LDEV exceeded the range. CMDRJE Executing 2E MP Blade ID is not in the effective range. CMDRJE Executing 2E The specified MP Blade is blocked. CMDRJE Executing 2E LDEV is not installed. CMDRJE Executing 2E The specified MP Blade is not installed. Table 9-21 SSB codes that are returned by raidcom delete device_grp command raidcom delete device_grp Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E It exceeds the range of LDEV number. CMDRJE Executing 2E LDEV is not installed. CMDRJE Executing 2E LDEV is not registered in the device group. CMDRJE Executing 2E A device group is not installed. CMDRJE Executing 2E22 000E The number of LDEVs that can be deleted in a operation exceeds the maximum. The number of LDEVs that can be deleted includes the number of LDEVs of a LUSE. CMDRJE Executing 2E The number of specified LDEVs is invalid. Table 9-22 SSB codes that are returned by raidcom add device_grp command raidcom add device_grp Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E It exceeds the range of LDEV number. CMDRJE Executing 2E LDEV is not installed. CMDRJE Executing 2E The number of device name in the system has reached the maximum. CMDRJE Executing 2E22 000A The device name of an LDEV is duplicated in the system. CMDRJE Executing 2E22 000E The number of LDEVs that can be registered in a operation exceeds the maximum. The number of LDEVs that can be registered includes the number of LDEVs of a LUSE. CMDRJE Executing 2E The number of specified LDEVs is invalid. Troubleshooting 9 41

324 raidcom add device_grp Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E It exceeds the number of device group in the system. CMDRJE Executing 2E The LDEV to be allocated to the device group is not set the device name. CMDRJE Executing 2E The specified resource group ID of the LDEV cannot be registered because it is different from other resource group ID of the LDEV in the specified device group. CMDRJE Executing 2EEA FEEC An internal error occurred. Call Hitachi Data Systems Support Center. Table 9-23 SSB codes that are returned by raidcom modify ldev -ldev_name command raidcom modify ldev -ldev_name Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E It exceeds the range of LDEV number. CMDRJE Executing 2E LDEV nickname is not specified. CMDRJE Executing 2E LDEV is not installed. Invalid Character Executing - - Unavailable character is included in LDEV nickname. Table 9-24 SSB codes that are returned by raidcom initialize ldev command raidcom initialize ldev Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E It exceeds the range of LDEV number. Async 2E The specified LDEV is used as a ShadowImage pair. Async 2E The specified LDEV is used as a TrueCopy pair or a Universal Replicator pair. Async 2E The specified LDEV is used as a Compatible FlashCopy V2 relationship. Async 2E The specified LDEV is used as a Thin Image or Copy-on-Write Snapshot pair. Async 2E The specified LDEV is used on the system disk. Async 2E LDEV is not blocked Troubleshooting

325 raidcom initialize ldev Error message Executing / Async Error code SSB1 SSB2 Description Async 2E The specified LDEV is a CC/XRC attribute device. Async 2E The specified LDEV is used as the primary volume of a GAD pair. Async 2E The specified LDEV is used as the secondary volume of a GAD pair. Async 2E The formatting operation cannot be done because the encryption value of the key number that is set to encryption ECC is invalid. Async 2E The formatting operation cannot be done because the check sum of the encryption key is not coincident. Async 2E The LDEV is in shredding. Async 2E The operation cannot be done because LDEV is now expanding. Async 2E11 001E The operation cannot be done because the virtual disk space is blocked. CMDRJE Executing 2E The specified LDEV is used in another operation. Async 2E The parity group of the target LDEV is in the state of correction copy. CMDRJE Executing 2E The parity group or the external volume group to which the specified LDEV belongs is used in another operation. Async 2E The operation of Dynamic Provisioning V-VOL cannot be done because there is a blocked pool. Async 2E The operation of Dynamic Provisioning V-VOL cannot be done because there is a blocked pool volume. Async 2E The operation cannot be done because the internal processing is in progress. CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command. Async 2E The processing stopped because aborting processing is required. CMDRJE Executing 2E LDEV is not installed. CMDRJE Executing 2E The program product is not installed. Async 2E The quick format cannot be performed because the total number of parity groups in which the LDEVs in quick formatting or the LDEVs blocked while quick formatting are implemented exceeds the maximum number that can be performed at the same time. Async 2E30 000A The specified LDEV is used as a Dynamic Provisioning. Troubleshooting 9 43

326 raidcom initialize ldev Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Async 2E30 000C The specified LDEV is used as a quorum disk. Executing Async 2E30 000E The specified LDEV is used as a pool volume. Async 2E30 000F The specified LDEV is used as a journal volume. Async 2E30 001A Volume Security is set to the specified LDEV. Async 2E30 002D Quick format cannot be done because the target LDEV is not an internal volume. Async 2E30 004E The specified LDEV is a Data Retention Utility/ Volume Retention Manager attribute device. Async 2E The specified LDEV is a pool volume and the pool volume include the Dynamic Provisioning volume that is not in the blocked status. Async 2E The specified LDEV cannot be operated because it is an external volume mapped for online data migration. Async 2E Maintenance work cannot be performed because the target LDEV is a quorum disk. Async 2E LDEV cannot be formatted because there is no normal external path. CMDRJE Executing 2EE8 00EE The command cannot be accepted. After a while, execute the same command. Async 2EE8 0A18 An internal error occurred. CMDRJE Executing Async 2EE8 FEEC An internal error occurred. Call Hitachi Data Systems Support Center. CMDRJE Executing 2EF The specified parameter is incorrect. Check the Command Control Interface Command Reference. Table 9-25 SSB codes that are returned by raidcom modify ldev -command_device raidcom modify ldev -command_device Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The command device cannot be set to the specified LDEV because of the following causes. The LDEV is used as a ShadowImage pair. The reserve attribute of a ShadowImage is configured Troubleshooting

327 raidcom modify ldev -command_device Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The specified LDEV is used as a TrueCopy pair. CMDRJE Executing 2E The specified LDEV is used as a Universal Replicator pair or a journal. CMDRJE Executing 2E The specified volume cannot be set because it is used by the Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The specified LDEV is used as the primary volume of a GAD pair. CMDRJE Executing 2E The specified LDEV is used as the secondary volume of a GAD. CMDRJE Executing 2E The specified LDEV is not defined. CMDRJE Executing 2E The following settings cannot be performed because the program product of LUN Manager is not installed. Command device settings Command security settings CMDRJE Executing 2E The emulation type of the specified volume is not OPEN volume. CMDRJE Executing 2E The command device cannot be set because LDEV is used as a Thin Image or Copy-on-Write Snapshot virtual volume. CMDRJE Executing 2E30 000C The specified volume cannot be set because it is a quorum disk. CMDRJE Executing 2E30 000D The specified volume cannot be set because it is a system disk. CMDRJE Executing 2E30 000E The specified volume cannot be set because it is a pool volume. CMDRJE Executing 2E The specified LDEV cannot be released because it is command device that is being used. CMDRJE Executing 2E The specified volume cannot be set because it is a LUSE volume. CMDRJE Executing 2E The command device cannot be set to the specified LDEV because of the following causes. It is used as a Volume Migration. The reserve attribute of a Volume Migration is configured. CMDRJE Executing 2E The specified LDEV cannot be set because it has a reserve attribute of a Data Retention Utility. CMDRJE Executing 2E The specified volume cannot be used as a command device because it is set by a Data Retention Utility. CMDRJE Executing 2E The specified LDEV cannot be operated because it is an external volume mapped for online data migration. Troubleshooting 9 45

328 raidcom modify ldev -command_device Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2EE8 FEEC An internal error occurred. Call Hitachi Data Systems Support Center. Table 9-26 SSB codes that are returned by raidcom modify ldev -ssid command raidcom modify ldev -ssid Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E SSID cannot be changed because there are LDEVs in the boundary where the specified LDEV belongs. CMDRJE Executing 2E The specified SSID is used for the other boundary. CMDRJE Executing 2EE8 FEEC An internal error occurred. Call Hitachi Data Systems Support Center. CMDRJE Executing 2EF The specified parameter is invalid. Check the Command Control Interface Command Reference. Table 9-27 SSB codes that are returned by raidcom modify ldev -status nml command raidcom modify ldev -status nml Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E It exceeds the range of LDEV number. Async 2E The specified LDEV is used as a ShadowImage pair. Async 2E The specified LDEV is used as a TrueCopy pair or a Universal Replicator pair. Async 2E The specified LDEV is used as a Compatible FlashCopy V2 relationship. Async 2E The specified LDEV is used as a Thin Image or Copy-on-Write Snapshot pair. Async 2E The specified LDEV is used as a system disk. CMDRJE Executing 2E LDEV is not blocked. Async 2E The specified LDEV is a CC/XRC attribute device. Async 2E10 001E The specified LDEV is not formatted after it is used as the journal volume. Async 2E The operation cannot be done because LDEV is not expanding Troubleshooting

329 raidcom modify ldev -status nml Error message Executing / Async Error code SSB1 SSB2 Description Async 2E11 001E The operation cannot be done because the virtual disk space is blocked. Async 2E The specified LDEV is used as the primary volume of a GAD pair. Async 2E The specified LDEV is used as the secondary volume of a GAD pair. CMDRJE Executing 2E The specified LDEV is used in another operation. CMDRJE Executing 2E The parity group or the external group to which the specified LDEV belongs is used in another operation. Async 2E The operation of Dynamic Provisioning V-VOL cannot be done because there is a blocked pool volume. Async 2E The operation cannot be done because the internal processing is in progress. CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command. CMDRJE Executing 2E The specified LDEV is not installed. Async 2E30 000A The specified LDEV is used as a Dynamic Provisioning. Async 2E30 000C The specified LDEV is used as a quorum disk. Async 2E30 000E The specified LDEV is used as a pool volume. Async 2E The specified LDEV is used as a reserved volume of Volume Migration. Async 2E30 001A Volume Security is set to the specified LDEV. Async 2E30 002C The specified LDEV cannot be restored because the shredding or the formatting operation has not been performed. Async 2E30 004E The specified LDEV is a Data Retention Utility/ Volume Retention Manager attribute device. Async 2E LDEV cannot be restored because there is no connection path to the normal external path. CMDRJE Executing 2EE8 00EE The command cannot be accepted. After a while, execute the same command. Troubleshooting 9 47

330 Table 9-28 SSB codes that are returned by raidcom modify ldev -status blk command raidcom modify ldev -status blk Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E It exceed the range of LDEV number. Async 2E The specified LDEV is used as a pair of ShadowImage/Thin Image/Copy-on-Write Snapshot/Volume Migration or a relationship of Compatible FlashCopy V2/Compatible Software for IBM FlashCopy SE. Async 2E The specified LDEV is used for a pair of TrueCopy or Universal Replicator. Async 2E The specified LDEV is used as a Compatible FlashCopy V2 relationship. Async 2E The specified LDEV is used as a Thin Image or Copy-on-Write Snapshot pair. Async 2E The specified LDEV is used as a system disk. CMDRJE Executing 2E LDEV is not installed, or LDEV is not in the state of Normal. Async 2E The specified LDEV is used at the concurrent copy or XRC. Async 2E The specified LDEV is used as the primary volume of an GAD pair. Async 2E The specified LDEV is used as the secondary volume of an GAD pair. Async 2E The operation cannot be done because LDEV is now expanding. Async 2E11 001E The operation cannot be done because the virtual disk space is blocked. CMDRJE Executing 2E The specified LDEV is used in another operation. CMDRJE Executing 2E The parity group or the external group to which the specified LDEV belongs is used in another operation. Async 2E The operation cannot be done because the internal processing is in progress. CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command. CMDRJE Execution 2E The specified LDEV is not installed. Async 2E30 000A The specified LDEV is used as a Dynamic Provisioning. Async 2E30 000C The specified LDEV is used as a quorum disk. Async 2E30 000E The specified LDEV is used as a pool volume. CMDRJE Executing 2E30 000F It is used as a journal Troubleshooting

331 raidcom modify ldev -status blk Error message Executing / Async Error code SSB1 SSB2 Description Async 2E The specified LDEV is used as a reserved volume of Volume Migration. Async 2E30 001A Volume Security is set to the specified LDEV. Async 2E30 001C It is used as a remote command device. Async 2E30 004E It is a volume that the Data Retention Utility is set. Async 2E30 004E The specified LDEV is a Data Retention Utility/ Volume Retention Manager attribute device. Async 2E It is used as a command device that is used at extended consistency group. Async 2E DP volume that is not in the blocked state is included in the DP volume associated with a pool that the pool volume is belongs to. Async 2E Maintenance work cannot be performed because the target LDEV is a quorum disk. Async 2E LDEV cannot be blocked because there is no connection path to the normal external path. Async 2EE8 0A18 An internal error occurred. Table 9-29 SSB codes that are returned by raidcom modify ldev -status enable_reallocation/disable_reallocation/new_page_allocation/ enable_relocation_policy command raidcom modify ldev -status enable_reallocation/disable_reallocation/ new_page_allocation/enable_relocation_policy Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E Invalid LDEV number. CMDRJE Executing 2E The tiering policy is not in the effective range. CMDRJE Executing 2E The new page assignment tier is invalid. CMDRJE Executing 2E The specified LDEV is not installed. CMDRJE Executing 2E The SM (Shared Memory) for Dynamic Tiering is not installed. CMDRJE Executing 2E30 000B The specified LDEV is not a virtual volume of Dynamic Provisioning/Dynamic Tiering. CMDRJE Executing 2E The specified LDEV is not a virtual volume of Dynamic Tiering. Troubleshooting 9 49

332 Table 9-30 SSB codes that are returned by raidcom modify ldev -status discard_zero_page command raidcom modify ldev -status discard_zero_page Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The specified LDEV is used as an ShadowImage pair. CMDRJE Executing 2E The specified LDEV is used as a TrueCopy pair. CMDRJE Executing 2E The specified LDEV is used as a Universal Replicator pair. CMDRJE Executing 2E The specified LDEV is used as a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The specified LDEV is used as a Volume Migration pair. CMDRJE Executing 2E The specified LDEV is blocked. CMDRJE Executing 2E10 600B The associated pool is blocked. CMDRJE Executing 2E Page cannot be discarded because the pool volume is being deleted or the Tier is being reallocated. CMDRJE Executing 2E The operation cannot be done because the system pool volume is blocked. CMDRJE Executing 2E The specified LDEV is not installed. CMDRJE Executing 2E30 000B The specified LDEV is not a virtual volume of Dynamic Provisioning/Dynamic Tiering. CMDRJE Executing 2E30 000F The specified LDEV is used as a journal volume. CMDRJE Executing 2E It is not associated to a pool. CMDRJE Executing 2E Page cannot be discarded because the specified LDEV is a TSE-VOL. CMDRJE Executing 2EE8 00E7 An internal error occurred. Call Hitachi Data Systems Support Center. Table 9-31 SSB codes that are returned by raidcom modify ldev -quorum_enable command raidcom modify ldev -quorum_enable Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The LDEV number is out of settable range. CMDRJE Executing 2E The device type is invalid. CMDRJE Executing 2E The serial number is invalid. CMDRJE Executing 2E00 A001 The quorum disk ID is out of settable range. Async 2E The specified LDEV is used for Volume Migration Troubleshooting

333 raidcom modify ldev -quorum_enable Error message Executing / Async Error code SSB1 SSB2 Description Async 2E The specified LDEV cannot be configured because the LDEV is a virtual volume. Async 2E10 A001 The specified quorum disk ID is being used. Async 2E10 A003 The specified quorum disk is in processing. Async 2E10 A005 The specified quorum disk is used as the quorum disk of the different device. Async 2E10 A006 The specified LDEV is used as the quorum disk. Async 2E11 001B The specified LDEV is being blocked. CMDRJE Executing 2E The specified LDEV is used for other operation. Async 2E The specified LDEV is not the first LDEV that belongs to the external volume group. CMDRJE Executing 2E LDEV is not installed. Async 2E20 000E The specified LDEV is not an external volume. Async 2E21 810A A shared memory is not installed. CMDRJE Async 2E Cache Residency Manager is set to the specified volume. Async 2E A path is defined to the specified volume. Async 2E30 000E The specified LDEV is used as a pool volume. Async 2E30 000F The specified LDEV is used as a journal volume. Async 2E The specified volume is used as a command device. Async 2E30 004E Data Retention Utility is set to the specified volume. Async 2E The specified LDEV cannot be operated because it is an external volume mapped for online data migration. Async 2E30 008E The emulation type of the specified LDEV is not OPEN-V. Async 2E The specified LDEV cannot be used because the size of LDEV is less than the minimum capacity of the quorum disk. Executing Async 2EE8 FEEC Internal error occurred. Troubleshooting 9 51

334 Table 9-32 SSB codes that are returned by raidcom delete lun command raidcom delete lun Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B The other than multiplatform volume or OPEN volume is included in the specified LDEV. CMDRJE Executing B D An used LDEV exists in the specified LDEV. CMDRJE Executing B It cannot be deleted because it is the last path of TrueCopy. CMDRJE Executing B It cannot be deleted because it is the last path of ShadowImage. CMDRJE Executing B A It cannot be deleted because it is the last path of Thin Image or Copy-on-Write Snapshot. CMDRJE Executing B B It cannot be deleted because it is the last path of Universal Replicator. CMDRJE Executing B It cannot be deleted because the operation object LU is executing host I/O. CMDRJE Executing B It cannot be deleted because the operation object LU is reserved. CMDRJE Executing B The command device is being used in the local Command Control Interface. CMDRJE Executing B A command device is being set. CMDRJE Executing B The command cannot be operated because the virtual LDEV is not defined yet. CMDRJE Executing B The value of LUN exceeds the maximum. CMDRJE Executing B The value of LDEV exceeds the maximum. CMDRJE Executing B The value of host group ID exceeds the maximum. CMDRJE Executing B The program product is not installed. CMDRJE Executing B Host group is not installed. CMDRJE Executing B D An invalid LDEV exists in the specified LDEVs. CMDRJE Executing B C The multiple LDEV cannot be specified. CMDRJE Executing B D When the host mode option 60 is set, LUN path of LUN0 cannot be set or released. CMDRJE Executing B The LU path cannot be deleted because the virtual LDEV ID of the specified volume was deleted. CMDRJE Executing B958 09A1 Another LDEV is already mapped in the specified LUN. CMDRJE Executing B9F9 B9F9 The command device is being used in the local Command Control Interface Troubleshooting

335 Table 9-33 SSB codes that are returned by raidcom add lun command raidcom add lun Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2EF An invalid LDEV exists in the specified LDEVs. CMDRJE Executing B LUN path cannot be set because it is reserved for Volume Migration. CMDRJE Executing B The attribute of the specified port is Initiator or External. CMDRJE Executing B The other than HMDE volume or OPEN volume is included in the specified LDEV. CMDRJE Executing B A An LU path has already defined in the relevant LDEV. CMDRJE Executing B D An invalid LDEV exists in the specified LDEVs. CMDRJE Executing B E It exceeds the maximum LUN under the port. CMDRJE Executing B LDEV is set as a pool volume. CMDRJE Executing B B LUN path cannot be set because the LDEV is a system disk. CMDRJE Executing B C LUN path cannot be set because the LDEV is a journal volume. CMDRJE Executing B D LUN path cannot be set because the access attribute of LDEV Data Retention Utility is reserved. CMDRJE Executing B958 01A3 When the host mode is Universal Volume Manager(0x4C), the LUN path cannot be set in the other than the external volume. CMDRJE Executing B958 01F2 The host group and the LDEV that configure the LU path do not exist in the same virtual storage machine. CMDRJE Executing B958 01F3 The LU path definition cannot be set because the virtual LDEV information of the specified LDEV is not defined yet. CMDRJE Executing B Command device cannot be set because it is reserved for Volume Migration. CMDRJE Executing B Command device cannot be set because it is an ShadowImage pair/or it is reserved. CMDRJE Executing B The command device cannot be operated because it is used at the local CCI. CMDRJE Executing B A A command device cannot be set because LDEV is other than the OPEN volume. CMDRJE Executing B D The specified LDEV is not installed. CMDRJE Executing B A command device cannot be set because LDEV is the virtual volume of Thin Image or Copy-on- Write Snapshot. CMDRJE Executing B The command cannot be operated because the virtual LDEV is not defined yet. CMDRJE Executing B The value of LUN exceeds the maximum. Troubleshooting 9 53

336 raidcom add lun Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B The value of LDEV exceeds the maximum. CMDRJE Executing B Another LDEV is already mapped to the specified LUN. CMDRJE Executing B The value of Host group ID exceeds the maximum. CMDRJE Executing B The program product is not installed. CMDRJE Executing B The specified host group is not installed. CMDRJE Executing B D An invalid LDEV exists in the specified LDEVs. CMDRJE Executing B C The multiple LDEV cannot be specified. CMDRJE Executing B D When the host mode option 60 is set, LUN path of LUN0 cannot be set or released. CMDRJE Executing B An invalid LDEV exists in the specified LDEVs. CMDRJE Executing B The LU path cannot be added because the virtual LDEV ID of the specified volume was deleted. Table 9-34 SSB codes that are returned by raidcom modify pool command raidcom modify pool Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The value of pool ID is invalid. CMDRJE Executing 2E The specified pool is for Thin Image or Copy-on- Write Snapshot. CMDRJE Executing 2E The value of maximum reserve ratio is out of range, or it falls below the maximum reserve ratio of the V-VOL. CMDRJE Executing 2E The specified Tier Range value is invalid. CMDRJE Executing 2E Relations between the specified lower limit of Tier Range and the Delta value is invalid. CMDRJE Executing 2E The specified Tier capacity threshold value is out of range. CMDRJE Executing 2E The threshold of the specified High water mark is out of range. CMDRJE Executing 2E00 600A The operation cannot be done because the specified threshold of Warning is larger than the threshold of the specified High water mark. CMDRJE Executing 2E The specified tier number is out of range. CMDRJE Executing 2E10 001F The operation cannot be done because the total capacity of virtual volumes for Dynamic Tiering in the system exceeds the maximum. CMDRJE Executing 2E10 600B The specified pool is in the state of blocked Troubleshooting

337 raidcom modify pool Error message Executing / Async Error code SSB1 SSB2 Description Async 2E10 600C The setting of the threshold value is less than the pool usage value. CMDRJE Executing 2E10 600D The operation cannot be done because it is in the state of shrinking. CMDRJE Executing 2E The operation cannot be done because it is being discarded pages. Async 2E Pool cannot be restored because the usage rate of pool is 100%. CMDRJE Executing 2E The operation cannot be done because the Tier is being deterred reallocation. CMDRJE Executing 2E The operation cannot be done because collecting the performance monitoring data is being prepared. CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command. CMDRJE Executing 2E The Dynamic Tiering operations cannot be done to the pool because the specified pool contains RAID 1 pool VOLs. CMDRJE Executing 2E The specified pool for Dynamic Provisioning cannot be changed to a pool for Dynamic Tiering because the pool is related to TSE-VOL. CMDRJE Executing 2E Pool ID is not installed. CMDRJE Executing 2E The specified Tier number is invalid. CMDRJE Executing 2E SM for Dynamic Provisioning is not installed. CMDRJE Executing 2E SM for Dynamic Tiering is not installed. CMDRJE Executing 2E30 006E The Dynamic Tiering operation cannot be done to the pool because the specified pool contains the external volumes whose cache mode is invalid. CMDRJE Executing 2E The threshold value 1 is out of range. CMDRJE Executing 2E The specified pool is for Thin Image or Copy-on- Write Snapshot. CMDRJE Executing 2E The specified pool must be assigned two userdefined thresholds to. CMDRJE Executing 2E30 600D The specified pool is not the pool for Dynamic Tiering. CMDRJE Executing 2E The specified pool includes the different RAID levels of volumes although the pool cannot include those volumes together. CMDRJE Executing 2E The specified pool includes external volumes although the pool cannot include those volumes together. CMDRJE Executing 2E The specified pool cannot be used for a Dynamic Tiering. Troubleshooting 9 55

338 raidcom modify pool Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The capacity that can be used by the installed program products exceeds the maximum. CMDRJE Executing 2E The program product is not installed. CMDRJE Executing 2EE Pool ID is not installed. CMDRJE Executing 2EE An internal error occurred at the pool operation. Call Hitachi Data Systems Support Center. CMDRJE Executing 2EE7 00EE The command cannot be accepted. After a while, execute the same command. CMDRJE Executing 2EE7 FEEC An internal error occurred in the pool operation. Call Hitachi Data Systems Support Center. Table 9-35 SSB codes that are returned by raidcom rename pool command raidcom rename pool Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The value of pool ID is out of range. CMDRJE Executing 2E The pool name cannot be changed because the pool configuration is being changed. CMDRJE Executing 2E Invalid pool ID. CMDRJE Executing 2E The pool name is duplicated with another pool. CMDRJE Executing 2EE7 FEEC An internal error occurred. Call Hitachi Data Systems Support Center. Table 9-36 SSB codes that are returned by raidcom delete pool command raidcom delete pool Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E LDEV# exceeds the range. CMDRJE Executing 2E The value of pool ID is out of range. Async 2E00 600B All pool volumes associated to a pool cannot be deleted. Async 2E The specified LDEV is in the state of blocked. CMDRJE Executing 2E10 600D This pool cannot be deleted because a volume in the pool is being deleted. Async 2E10 600E The operation cannot be done because the pool usage rate exceed the threshold value of the pool usage Troubleshooting

339 raidcom delete pool Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Async 2E10 600F The operation cannot be done because the current capacity rate exceeds the value of maximum reserved capacity rate. Async 2E It cannot be deleted because the pool volume is set in the state of being deterred deleting. Async 2E Deleting operation cannot be done because it is being discarded pages. Async 2E The specified operation is not supported in the current microcode version. Async 2E11 001F The operation cannot be done because a Thin Image or Copy-on-Write Snapshot pair remains or the association with a Dynamic Provisioning virtual volume exists. Async 2E The operation cannot be done because a Thin Image or Copy-on-Write Snapshot pair is being deleted or a Dynamic Provisioning virtual volume is being deleted. Async 2E The operation cannot be done because a pool volume of a specified pool is being formatted. Executing/ Async 2E The pool is not in the status where the pool can be deleted or a pool volume can be deleted. Async 2E The operation cannot be done because the power supply is switched off. CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command. CMDRJE Executing 2E The specified LDEV is not registered to the pool. CMDRJE Async 2E The operation cannot be done because the pool volume is not of a specified pool. Executing/ Async 2E Pool ID is not installed. Async 2E The operation cannot be performed because the shared memory (SM) is not initialized. CMDRJE Executing 2E The number of specified LDEVs is invalid. CMDRJE Executing 2E The specified LDEV cannot be deleted because it is a top VOL of the pool. CMDRJE Executing 2E The specified pool is a pool for Thin Image or Copy-on-Write Snapshot. CMDRJE Executing 2EE7 00EE The command cannot be accepted. After a while, execute the same command. CMDRJE Executing 2EE7 00F9 Pool ID is not installed. CMDRJE Executing 2EE7 FEEC An internal error occurred. Call Hitachi Data Systems Support Center. Troubleshooting 9 57

340 raidcom delete pool Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2EF The specified parameter is invalid. Check the Command Control Interface Command Reference. Table 9-37 SSB codes that are returned by raidcom add snap_pool command raidcom add snap_pool Error message Executing / Async Error code SSB1 SSB2 Description Async 2E The value of LDEV number is out of range. CMDRJE Executing 2E Pool ID is out of range. CMDRJE Executing 2E The type of pool is invalid. CMDRJE Executing 2E The maximum reserve ratio for V-VOL is out of range. Async 2E10 000C The operation cannot be done because a SATA-E drive in the state of quick formatting is in the specified LDEV. Async 2E The specified LDEV is in the state of blocked. CMDRJE Executing 2E The specified LDEV is in the state of blocked, or not installed. CMDRJE Async 2E Thin Image cannot be used because there are not enough cache management devices to create pairs. Async 2E The pool cannot be created because there are not enough resources (VDEV) depending on cache management devices. Async 2E10 600D The operation cannot be performed because the pool volume is being deleted. Executing /Async 2E The pool is not in the status where the pool volume can be added. Async 2E The operation cannot be done because the power supply is switched off. CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command. Async 2E The specified LDEV is not installed. Async 2E The operation cannot be performed because the memory capacity of the shared memory (SM) is insufficient. Async 2E The operation cannot be done because the SM for Thin Image or Copy-on-Write Snapshot is not initialized Troubleshooting

341 raidcom add snap_pool Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E Thin Image or Copy-on-Write Snapshot program product is not installed. Async 2E Exceeded the number of pool volume that can be registered in a pool. Async 2E22 000D The larger number of drive types than the supported configuration cannot be added to the specified pool. Async 2E Pool volume cannot be registered because the drive type of specified LDEV is different from the other pool volume type, or the drive type in the pool exceeds the three. CMDRJE Executing 2E The number of specified LDEVs is invalid. Async 2E The emulation type of specified LDEV cannot be used as a pool VOL. Async 2E The specified LDEV has the LU path definition. Async 2E30 000C The specified LDEV is used as a quorum disk. Async 2E30 000D The specified LDEV is used as a system disk. Async 2E30 000E The specified LDEV is already used as a pool volume. Async 2E The specified LDEV is a command device. Async 2E It cannot be used as a pool volume because the size of specified LDEV is less than 8GB. Async 2E Creating a pool or adding a pool volume cannot be done because CLPR is mixed in the specified pool. Async 2E30 005C The specified LDEV is used as a V-VOL. Async 2E30 005E The specified LDEV is used in another program product. CMDRJE Executing 2E30 006C An LDEV, whose emulation type is not available to be mixed, is in the specified LDEVs. CMDRJE Executing 2E30 006D The emulation type of the specified volume is not OPEN-V. Async 2E30 006E The operation cannot be done for the following reasons: The pool volumes include external volumes whose cache modes are invalid. The pool includes both external volumes whose cache modes are invalid and internal volumes. Troubleshooting 9 59

342 raidcom add snap_pool Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing Async 2E A pool volume cannot be added because the LDEV of the resource group different from the resource group of the pool volume to which the specified pool belongs is specified. Async 2E The specified LDEV cannot be operated because it is an external volume mapped for online data migration. Async 2E The specified volume cannot be used as a pool volume. CMDRJE Executing 2E The threshold value 1 is out of range. Async 2E The specified pool attribute differs from the pool attribute of existed pool. Async 2E The RAID level of the specified LDEV is different from the RAID level of the other pool volumes. Async 2E There is a blocked pool volume. Async 2E External volumes whose cache modes are different are included. CMDRJE Executing 2E The POOL Name is duplicated with another pool. CMDRJE Async 2E The pool cannot include volumes in different RAID levels because the pool cannot include those volumes. Or the pool cannot include the RAID 1 volumes and the volumes of other RAID levels together. Async 2E The pool cannot include both internal volumes and external volumes because the pool is not set to Mixable. Async 2E The usage capacity exceeds the license capacity of program product. Executing Async 2EE7 FEEC An internal error occurred. Call Hitachi Data Systems Support Center. CMDRJE Executing 2EF The specified parameter is invalid. Check the Command Control Interface Command Reference. Table 9-38 SSB codes returned by raidcom add snapshot raidcom add snapshot Error message Executing /Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The value exceeds the range of LDEV number. CMDRJE Executing 2E A pair cannot be created because there are not enough cache management devices Troubleshooting

343 Error message Executing /Async Error code SSB1 SSB2 raidcom add snapshot Description CMDRJE Executing 2E The command ends abnormally because the volume out of the range of LDEV number is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the volume out of the range of LDEV number is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The specified pool ID is out of the range. CMDRJE Executing 2E There are not enough required input parameters. CMDRJE Executing 2E A pair cannot be created because the volume exceeded the support size is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E A pair cannot be created because the volume exceeded the support size is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E A pair cannot be created because the V-VOL is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E A pair cannot be created because the pool-vol is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E A pair cannot be created because the journal volume of Universal Replicator is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the LUSE volumes of different structure are specified as the P-VOL and the S-VOL. CMDRJE Executing 2E A pair cannot be created because the volume in which the VMA is set is specified as the P-VOL. CMDRJE Executing 2E A pair cannot be created because the external volume is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E A pair cannot be created because the volume other than V-VOL is specified as the S-VOL of a Thin Image or Copyon-Write Snapshot pair. CMDRJE Executing 2E A pair cannot be created because the pool-vol is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E10 002A A pair cannot be created because the volume (the data volume or the journal volume) of the Universal Replicator pair that is in the intermediate site of the 3DC cascading configuration is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E10 002B A pair cannot be created because the P-VOL of a Universal Replicator pair is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. Troubleshooting 9 61

344 Error message Executing /Async Error code SSB1 SSB2 raidcom add snapshot Description CMDRJE Executing 2E10 002C A pair cannot be created because the S-VOL of a Universal Replicator pair is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E10 002D A pair cannot be created because the journal volume of the Universal Replicator is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E10 002E The command ends abnormally because the volume that is set the S-VOL Disable is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E10 002F A pair cannot be created because the volume that is set the VMA is specified as the S-VOL of a Thin Image or Copyon-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the volumes of different Max LBA size are specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair and S-VOL. CMDRJE Executing 2E The command ends abnormally because the volumes in which the number of slots is different are specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair and S-VOL. CMDRJE Executing 2E A pair cannot be created because the Dynamic Provisioning V-VOL is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the ShadowImage reserved volume is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the Volume Migration source volume is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the Volume Migration target volume is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the Volume Migration reserved volume is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the P-VOL of a ShadowImage pair is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the S-VOL of a ShadowImage pair is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the ShadowImage reserved volume is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E10 003A The command ends abnormally because the Volume Migration source volume is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair Troubleshooting

345 Error message Executing /Async Error code SSB1 SSB2 raidcom add snapshot Description CMDRJE Executing 2E10 003B The command ends abnormally because the Volume Migration target volume is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E10 003C The command ends abnormally because the Volume Migration reserved volume is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E10 003D A Thin Image or Copy-on-Write Snapshot pair cannot be created because the volume of Universal Replicator for the delta resync is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E10 003E A Thin Image or Copy-on-Write Snapshot pair cannot be created because the volume of Universal Replicator for the delta resync is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E10 003F The command ends abnormally because the Quorum disk is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the Quorum disk is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E A Thin Image or Copy-on-Write Snapshot pair cannot be created because the Dynamic Provisioning V-VOL in capacity expanding is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E A Thin Image or Copy-on-Write Snapshot pair cannot be created because the Dynamic Provisioning V-VOL that is discharging zero data is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E A pair cannot be created because the P-VOL of a TrueCopy pair is specified as the S-VOL of a Thin Image or Copy-on- Write Snapshot pair. CMDRJE Executing 2E A pair cannot be created because the S-VOL of a TrueCopy pair is specified as the S-VOL of a Thin Image or Copy-on- Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the ShadowImage pair is being resynchronized when the volume is shared between the P-VOL of a Thin Image/ Copy-on-Write Snapshot pair and the P-VOL of a ShadowImage pair. CMDRJE Executing 2E10 004A The command ends abnormally because the ShadowImage pair status is other than PSUS when the volume is shared between P-VOL of a Thin Image/Copyon-Write Snapshot pair and the S-VOL of a ShadowImage pair. CMDRJE Executing 2E10 004E The operation cannot be performed because the Quick Restore is being operated on the specified ShadowImage P-VOL. Troubleshooting 9 63

346 Error message Executing /Async Error code SSB1 SSB2 raidcom add snapshot Description CMDRJE Executing 2E A pair operations cannot be performed because the volume using 2 mirrors included in the 3DC multi-target configuration, 3DC cascade configuration or 3DC delta resync configuration by the 3 Universal Replicator sites is specified. CMDRJE Executing 2E A Thin Image pair cannot be created because the pair status of all Thin Image pairs sharing the specified P-VOL is PSUE. CMDRJE Executing 2E10 005B A Thin Image pair cannot be operated because the virtual storage machine of the P-VOL is different from the virtual storage machine of the S-VOL. CMDRJE Executing 2E10 005C A Thin Image pair cannot be operated because changing the model and the serial number in the virtual storage machine of the specified P-VOL is in progress. CMDRJE Executing 2E10 005D A Thin Image pair cannot be operated because changing the model and the serial number in the virtual storage machine of the specified S-VOL is in progress. CMDRJE Executing 2E A Thin Image or Copy-on-Write Snapshot pair with the specified consistency group number cannot be created due to one of the following reasons: The specified consistency group number is used by the ShadowImage. The number of pairs that can be defined in a consistency group exceeds the maximum. The pair created by using the same P-VOL already exists in the specified consistency group. CMDRJE Executing 2E A Thin Image pair specifying CTG mode cannot be created because the maximum number of consistency groups has already been defined. CMDRJE Executing 2E A Thin Image or Copy-on-Write Snapshot pair cannot be created due to unavailable of the pool. CMDRJE Executing 2E A Thin Image or Copy-on-Write Snapshot pair cannot be created because there are not enough pair tables. CMDRJE Executing 2E A Thin Image or Copy-on-Write Snapshot pair cannot be created because there are not enough differential tables. CMDRJE Executing 2E A pair cannot be created because there is not enough free shared memory space. CMDRJE Executing 2E The command ends abnormally because the pair is in the state of unacceptable the command. CMDRJE Executing 2E A Thin Image or Copy-on-Write Snapshot pair cannot be created because the number of Thin Image or Copy-on- Write Snapshot pairs has already reached the maximum. CMDRJE Executing 2E A Thin Image pair cannot be created because the maximum number of Snapshot IDs (MU numbers) has already been in use for the specified P-VOL Troubleshooting

347 Error message Executing /Async Error code SSB1 SSB2 raidcom add snapshot Description CMDRJE Executing 2E A Thin Image pair cannot be created because the maximum number of Snapshot groups has already been defined, or the maximum number of Thin Image pairs has already been defined in the specified Snapshot group. CMDRJE Executing 2E A Thin Image pair cannot be created because the DP pool is being initialized. CMDRJE Executing 2E An error occurred at the operation of Thin Image due to one of the following reasons: The LDEV number specified for the P-VOL or the S-VOL is incorrect. The LDEV specified as the P-VOL or the S-VOL is not paired. The pair of the specified P-VOL or the S-VOL is not ready to perform the specified operation. The specified Snapshot ID (MU number) is wrong. The specified Snapshot ID (MU number) is already used. The specified pool is not in the usable status. The license capacity has exceeded the maximum. The control table for Thin Image is depleted. CMDRJE Executing 2E The operation cannot be performed because power-off is in progress. CMDRJE Executing 2E A Thin Image or Copy-on-Write Snapshot pair cannot be created because the specified P-VOL is a LUSE volume. CMDRJE Executing 2E A pair cannot be created because there is a pair in the specified primary volume, which is using a different pool number from the specified pool number. CMDRJE Executing 2E The specified pair operation cannot be performed for the specified pool. CMDRJE Executing 2E The consistency group to be used in the specified Snapshot Group is in one of the following status: The number of pairs that can be defined in a consistency group exceeds the maximum. The pair created by using the same P-VOL already exists in the specified consistency group. CMDRJE Executing 2E The specified LDEV is not defined. CMDRJE Executing 2E The command ends abnormally because an unmounted volume is specified as the P-VOL of a Thin Image or Copyon-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the blocked volume is specified as the P-VOL of a Thin Image or Copyon-Write Snapshot pair. CMDRJE Executing 2E20 000A The command ends abnormally because the volume in formatting operation is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. Troubleshooting 9 65

348 Error message Executing /Async Error code SSB1 SSB2 raidcom add snapshot Description CMDRJE Executing 2E20 000B The command ends abnormally because an unmounted volume is specified as the S-VOL of a Thin Image or Copyon-Write Snapshot pair. CMDRJE Executing 2E20 000C The command ends abnormally because the blocked volume is specified as the S-VOL of a Thin Image or Copyon-Write Snapshot pair. CMDRJE Executing 2E20 000D The command ends abnormally because the volume in formatting operation is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the shared memory (FC, TPF, or Extension1) is not expanded for necessary capacity. CMDRJE Executing 2E The command ends abnormally because the shared memory (SS1 or more) is not expanded for necessary capacity. CMDRJE Executing 2E A Thin Image or Copy-on-Write Snapshot pair cannot be created due to one of the following reasons: The shared memory is not expanded for necessary capacity. It is in the initializing process. CMDRJE Executing 2E The program product is not installed. CMDRJE Executing 2E30 000C The specified LDEV is used as a quorum disk. CMDRJE Executing 2E A pair cannot be created because the volume is already used in the S-VOL of a Thin Image or Copy-on-Write Snapshot pair is specified as the P-VOL. CMDRJE Executing 2E A pair cannot be created because the volume is already used in the P-VOL of a Thin Image or Copy-on-Write Snapshot pair is specified as the S-VOL. CMDRJE Executing 2E A pair cannot be created because the volume is already used in the S-VOL of a Thin Image or Copy-on-Write Snapshot pair is specified as the S-VOL. CMDRJE Executing 2E30 007A The command ends abnormally because the volume other than OPEN-V is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E30 007B A pair cannot be created because the volume that is set the command device is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E30 007C The command ends abnormally because the volume other than OPEN-V is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E30 007D A pair cannot be created because the volume that is set the command device is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E30 007E The command ends abnormally because the volume that has no path definition is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair Troubleshooting

349 Error message Executing /Async Error code SSB1 SSB2 raidcom add snapshot Description CMDRJE Executing 2E30 007F The command ends abnormally because the volume that has no path definition is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the external volume mapped for the online data migration is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the external volume mapped for the online data migration is specified as the S-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The pair operation is rejected because the specified volume as the primary volume is a reserved volume for GAD, or a volume for the GAD pair which is in the invalid status. CMDRJE Executing 2E The pair operation is rejected because the specified volume as the secondary volume is a reserved volume for GAD, or a volume for a GAD pair. CMDRJE Executing 2E30 600E A pair cannot be created because the attribute of the pool is other than Thin Image or Copy-on-Write Snapshot is specified. CMDRJE Executing 2E A pair cannot be created because the capacity exceeds the licensed capacity. CMDRJE Executing 2E3F 8000 The specified operation is not supported in the current microcode version. CMDRJE Executing 2EC6 FEEC An internal error occurred. Call Hitachi Data Systems Support Center. Table 9-39 SSB codes returned by raidcom modify snapshot raidcom modify snapshot Error message Executing /Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The value exceeds the range of LDEV number. CMDRJE Executing 2E00 000B The MU number exceeds the maximum. CMDRJE Executing 2E The command ends abnormally because the volume out of the range of LDEV number is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the ShadowImage reserved volume is specified as the P- VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the Volume Migration source volume is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. Troubleshooting 9 67

350 raidcom modify snapshot Error message Executing /Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The command ends abnormally because the Volume Migration target volume is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the Volume Migration reserved volume is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E10 003F The command ends abnormally because the Quorum disk is specified as the P-VOL of a Thin Image or Copyon-Write Snapshot pair. CMDRJE Executing 2E The Thin Image or Copy-on-Write Snapshot pair cannot be restored because the TrueCopy pair status is other than PSUS or PSUE when the volume is shared between the P-VOL of a Thin Image/Copy-on-Write Snapshot pair and the P-VOL of a TrueCopy pair. CMDRJE Executing 2E A Thin Image or Copy-on-Write Snapshot pair cannot be restored because the Universal Replicator pair status is other than PSUS or PSUE when the volume is shared between the P-VOL of a Thin Image/Copy-on-Write Snapshot pair and the P-VOL of a Universal Replicator pair. CMDRJE Executing 2E A Snapshot data cannot be obtained because the TrueCopy pair status is COPY when the volume is shared between the P-VOL of a Thin Image/Copy-on- Write Snapshot pair and the S-VOL of a TrueCopy pair. CMDRJE Executing 2E A Snapshot data cannot be obtained because the Universal Replicator pair status is COPY when the volume is shared between the P-VOL of a Thin Image/ Copy-on-Write Snapshot pair and the S-VOL of a Universal Replicator pair. CMDRJE Executing 2E The command ends abnormally because the ShadowImage pair is being resynchronized when the volume is shared between the P-VOL of a Thin Image/ Copy-on-Write Snapshot pair and the P-VOL of a ShadowImage pair. CMDRJE Executing 2E10 004A The command ends abnormally because the ShadowImage pair status is other than PSUS when the volume is shared between P-VOL of a Thin Image/Copyon-Write Snapshot pair and the S-VOL of a ShadowImage pair. CMDRJE Executing 2E10 004B The Thin Image or Copy-on-Write Snapshot pair cannot be restored because the Thin Image or Copy-on-Write Snapshot pair status is other than PSUS or PSUE when the volume is shared between the P-VOL of a Thin Image/Copy-on-Write Snapshot pair and the P-VOL of a ShadowImage pair Troubleshooting

351 raidcom modify snapshot Error message Executing /Async Error code SSB1 SSB2 Description CMDRJE Executing 2E10 004C The Thin Image or Copy-on-Write Snapshot pair cannot be restored because the Thin Image or Copy-on-Write Snapshot pair status is other than PSUS when the volume is shared between the P-VOL of a Thin Image/ Copy-on-Write Snapshot pair and the S-VOL of a ShadowImage pair. CMDRJE Executing 2E10 004D A Snapshot data cannot be obtained because the TrueCopy asynchronous pair status is other than PSUS or PSUE when the volume is shared between the P-VOL of a Thin Image/Copy-on-Write Snapshot pair and the S-VOL of a TrueCopy asynchronous pair. CMDRJE Executing 2E10 004E The operation cannot be performed because the Quick Restore is being operated on the specified ShadowImage P-VOL. CMDRJE Executing 2E A pair operation cannot be performed because the volume using two mirrors included in the 3DC multitarget configuration, 3DC cascade configuration or 3DC delta resync configuration by the three Universal Replicator sites is specified. CMDRJE Executing 2E A Thin Image pair operation cannot be performed because the pair status of all Thin Image pairs sharing the specified P-VOL is PSUE. CMDRJE Executing 2E The Thin Image pair operation cannot be performed because the virtual LDEV ID of the specified volume was deleted. CMDRJE Executing 2E A Thin Image or Copy-on-Write Snapshot pair cannot be created due to unavailable of the pool. CMDRJE Executing 2E A Snapshot data cannot be obtained because the pool or the pool-vol is blocked. CMDRJE Executing 2E A Thin Image or Copy-on-Write Snapshot pair cannot be created because there are not enough pair tables. CMDRJE Executing 2E A Thin Image or Copy-on-Write Snapshot pair cannot be created because there are not enough differential tables. CMDRJE Executing 2E A pair cannot be created because there is not enough free shared memory space. CMDRJE Executing 2E The command ends abnormally because other than the raidcom add snapshot command is issued for the volume other than the Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the pair is in the state of unacceptable the command. CMDRJE Executing 2E The Thin Image or Copy-on-Write Snapshot pair cannot be restored because the volume is shared between the P-VOL of a Thin Image/Copy-on-Write Snapshot pair and the S-VOL of a TrueCopy pair. Troubleshooting 9 69

352 raidcom modify snapshot Error message Executing /Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The Thin Image or Copy-on-Write Snapshot pair cannot be restored because the volume is shared between the P-VOL of a Thin Image/Copy-on-Write Snapshot pair and the S-VOL of a Universal Replicator pair. CMDRJE Executing 2E The Thin Image or Copy-on-Write Snapshot pair cannot be restored due to one of the following reasons: Snapshot data of a restore target Thin Image or Copy-on-Write Snapshot pair is being obtained per consistency group. Snapshot data of a different pair whose primary volume is the restore target P-VOL of a Thin Image or Copy-on-Write Snapshot pair is being obtained per consistency group. CMDRJE Executing 2E An error occurred at the operation of Thin Image due to one of the following reasons: The LDEV number specified for the P-VOL or the S- VOL is incorrect. The LDEV specified as the P-VOL or the S-VOL is not paired. The pair of the specified P-VOL or the S-VOL is not ready to perform the specified operation. The specified Snapshot ID (MU number) is wrong. The specified Snapshot ID (MU number) is already used. The specified pool is not in the usable status. The license capacity has exceeded the maximum. The control table for Thin Image is depleted. CMDRJE Executing 2E The operation cannot be performed because power-off is in progress. CMDRJE Executing 2E The specified LDEV is not defined. CMDRJE Executing 2E The command ends abnormally because an unmounted volume is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the blocked volume is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E20 000A The command ends abnormally because the volume in formatting operation is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the shared memory (FC, TPF, or Extension3) is not expanded for necessary capacity. CMDRJE Executing 2E The command ends abnormally because the shared memory (SS3 or more) is not expanded for necessary capacity. CMDRJE Executing 2E The program product is not installed Troubleshooting

353 raidcom modify snapshot Error message Executing /Async Error code SSB1 SSB2 Description CMDRJE Executing 2E30 000C The specified LDEV is used as a quorum disk. CMDRJE Executing 2E The Thin Image or Copy-on-Write Snapshot pair cannot be restored because the volume that is set the S-VOL Disable is specified as the P-VOL. CMDRJE Executing 2E30 007A The command ends abnormally because the volume other than OPEN-V is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the external volume mapped for the online data migration is specified as the S-VOL of a Thin Image or Copy-on- Write Snapshot pair. CMDRJE Executing 2E The pair operation is rejected because the specified volume as the primary volume is a reserved volume for GAD, or the volume for the GAD pair which is in the invalid status. CMDRJE Executing 2E The pair operation is rejected because the specified volume as the secondary volume is a reserved volume for GAD, or the volume for the GAD pair. CMDRJE Executing 2E3F 8000 The specified operation is not supported in the current microcode version. CMDRJE Executing 2EC6 FEEC An internal error occurred. Call Hitachi Data Systems Support Center. CMDRJE Executing 2EF The specified parameter is invalid. Check the Hitachi Command Control Interface Command Reference. Table 9-40 SSB codes returned by raidcom get snapshot raidcom get snapshot Error message Executing /Async Error code SSB1 SSB2 Description CMDRJE Executing 2EC5 FEEC An internal error occurred. Call Hitachi Data Systems Support Center. Table 9-41 SSB codes returned by raidcom delete snapshot raidcom delete snapshot Error message Executing /Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The value exceeds the range of LDEV number. CMDRJE Executing 2E00 000B The MU number exceeds the maximum. CMDRJE Executing 2E The command ends abnormally because the volume out of the range of LDEV number is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. Troubleshooting 9 71

354 raidcom delete snapshot Error message Executing /Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The command ends abnormally because the ShadowImage reserved volume is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the Volume Migration source volume is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the Volume Migration target volume is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the Volume Migration reserved volume is specified as the P-VOL of a Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the ShadowImage pair is being resynchronized when the volume is shared between the P-VOL of a Thin Image/ Copy-on-Write Snapshot pair and the P-VOL of a ShadowImage pair. CMDRJE Executing 2E10 004A The command ends abnormally because the ShadowImage pair status is other than PSUS when the volume is shared between P-VOL of a Thin Image/Copyon-Write Snapshot pair and the S-VOL of a ShadowImage pair. CMDRJE Executing 2E10 004D A Snapshot data cannot be obtained because the TrueCopy asynchronous pair status is other than PSUS or PSUE when the volume is shared between the P-VOL of a Thin Image/Copy-on-Write Snapshot pair and the S-VOL of a TrueCopy asynchronous pair. CMDRJE Executing 2E10 004E The operation cannot be performed because the Quick Restore is being operated on the specified ShadowImage P-VOL. CMDRJE Executing 2E A Snapshot data cannot be obtained because the pool or the pool-vol is blocked. CMDRJE Executing 2E The command ends abnormally because other than the raidcom add snapshot command is issued for the volume other than the Thin Image or Copy-on-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the pair is in the state of unacceptable the command Troubleshooting

355 raidcom delete snapshot Error message Executing /Async Error code SSB1 SSB2 Description CMDRJE Executing 2E An error occurred at the operation of Thin Image due to one of the following reasons: The LDEV number specified for the P-VOL or the S- VOL is incorrect. The LDEV specified as the P-VOL or the S-VOL is not paired. The pair of the specified P-VOL or the S-VOL is not ready to perform the specified operation. The specified Snapshot ID (MU number) is wrong. The specified Snapshot ID (MU number) is already used. The specified pool is not in the usable status. The license capacity has exceeded the maximum. The control table for Thin Image is depleted. CMDRJE Executing 2E The operation cannot be performed because power-off is in progress. CMDRJE Executing 2E The specified LDEV is not defined. CMDRJE Executing 2E The command ends abnormally because an unmounted volume is specified as the P-VOL of a Thin Image or Copyon-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the blocked volume is specified as the P-VOL of a Thin Image or Copyon-Write Snapshot pair. CMDRJE Executing 2E The command ends abnormally because the shared memory (FC, TPF, or Extension2) is not expanded for necessary capacity. CMDRJE Executing 2E The command ends abnormally because the shared memory (SS2 or more) is not expanded for necessary capacity. CMDRJE Executing 2EC6 FEEC An internal error occurred. Call Hitachi Data Systems Support Center. Table 9-42 SSB codes that are returned by raidcom add ssid command raidcom add ssid Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The CU number of the RCU exceeds the effective value. CMDRJE Executing 2E The command cannot be executed because the parameter of the specified RCU is invalid. CMDRJE Executing 2E The CU number is out of effective range. CMDRJE Executing 2E The operation cannot be done because the microcode is being changed. Troubleshooting 9 73

356 raidcom add ssid Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The serial number, product ID, or SSID of the target storage system is incorrect. CMDRJE Executing 2E The command cannot be executed because the specified RCU is not registered. CMDRJE Executing 2E The operation cannot be performed due to one of the following reasons: The number of RCUs registered in MCU or RCU is more than four. The number of RCUs registered in the system is more than 64 in the case of specifying the cu free. CMDRJE Executing 2E The number of the specified SSIDs is invalid. CMDRJE Executing 2E The command cannot be executed because the RCU identification code of a path is invalid. CMDRJE Executing 2ED6 00EF An internal error occurred. Call Hitachi Data Systems Support Center. CMDRJE Executing 2ED The SSID is invalid. CMDRJE Executing 2EF The specified parameter is invalid. Check the Command Control Interface Command Reference. Table 9-43 SSB codes that are returned by raidcom delete ssid command raidcom delete ssid Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The CU number of the RCU exceeds the effective value. CMDRJE Executing 2E The command cannot be executed because the parameter of the specified RCU is invalid. CMDRJE Executing 2E The CU number is out of effective range. CMDRJE Executing 2E The operation cannot be done because the microcode is being changed. CMDRJE Executing 2E The serial number, the product ID, or the SSID of the remote storage system is invalid. CMDRJE Executing 2E The command cannot be executed because the specified RCU is not registered. CMDRJE Executing 2E The number of the specified SSIDs is invalid. CMDRJE Executing 2ED6 00EF An internal error occurred. Call Hitachi Data Systems Support Center. CMDRJE Executing 2ED The SSID is invalid. CMDRJE Executing 2EF The specified parameter is invalid. Check the Command Control Interface Command Reference Troubleshooting

357 Table 9-44 SSB codes that are returned by raidcom add dp_pool command raidcom add dp_pool Error message Executing / Async Error code SSB1 SSB2 Description Async 2E LDEV number is out of rage. CMDRJE Executing 2E The value of pool ID is out of range. CMDRJE Executing 2E The type of pool is invalid. CMDRJE Executing 2E The maximum reserve ratio of V-VOL is out of range. CMDRJE Executing 2E The threshold of the specified High water mark is out of range. CMDRJE Executing 2E00 600A The operation cannot be done because the specified threshold of Warning is larger than the threshold of the specified High water mark. Async 2E The specified LDEV is in the state of blocked. Async 2E10 000C The operation cannot be done because a SATA-E drive in the state of quick formatting is in the specified LDEV. CMDRJE Executing 2E The specified LDEV is in the state of blocked, or not installed. CMDRJE Async 2E The pool cannot be created because there are not enough resources (VDEV) depending on cache management devices. Async 2E10 600D The operation cannot be performed because the pool volume is being deleted. Async 2E The specified operation is not supported in the current microcode version. Executing /Async 2E The pool is not in the status where the pool volume can be added. Async 2E The operation cannot be done because the power supply is switched off. CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command. Async 2E The specified LDEV is not installed. Async 2E The operation cannot be performed because the memory capacity of the shared memory (SM) is insufficient. Async 2E The operation cannot be performed because the shared memory (SM) is not initialized. CMDRJE Executing 2E Dynamic Provisioning program product is not installed. Async 2E Exceeded the number of pool volume that can be registered in a pool. Troubleshooting 9 75

358 raidcom add dp_pool Error message Executing / Async Error code SSB1 SSB2 Description Async 2E22 000D The larger number of drive types than the supported configuration cannot be added to the specified pool. Async 2E Pool volume cannot be registered because the drive type of specified LDEV is different from the other pool volume type, or the drive type in the pool exceeds three. CMDRJE Executing 2E The number of specified LDEVs is invalid. Async 2E The emulation type of specified LDEV cannot be used as a pool VOL. Async 2E The specified LDEV has the LU path definition. Async 2E30 000C The specified LDEV is used as a quorum disk. Async 2E30 000D The specified LDEV is used as a system disk. Async 2E30 000E The specified LDEV is already used as a pool volume. Async 2E The specified LDEV is a command device. Async 2E It cannot be used as a pool volume because the size of specified LDEV is less than 8GB. Async 2E Creating a pool or adding a pool volume cannot be done because CLPR is mixed in the specified pool. Async 2E30 005C The specified LDEV is used as a V-VOL. Async 2E30 005D The specified LDEV is a volume of unsupported Dynamic Tiering. Async 2E30 005E The specified LDEV is used in another program product. CMDRJE Executing 2E30 006C An LDEV, whose emulation type is not available to be mixed, is in the specified LDEVs. CMDRJE Async 2E30 006E The operation cannot be done for the following reasons: The pool volumes to be added to the Dynamic Tiering pool include external volumes whose cache modes are invalid. The Dynamic Provisioning pool includes both external volumes whose cache modes are invalid and internal volumes. Executing Async 2E A pool volume cannot be added because the LDEV of the resource group different from the resource group of the pool volume to which the specified pool belongs is specified Troubleshooting

359 raidcom add dp_pool Error message Executing / Async Error code SSB1 SSB2 Description Async 2E The specified LDEV cannot be operated because it is an external volume mapped for online data migration. Async 2E The specified volume cannot be used as a pool volume. CMDRJE Executing 2E The threshold value 1 is out of range. Async 2E The specified pool attribute differs from the pool attribute of existed pool. Async 2E The RAID level of the specified LDEV is different with the RAID level of others. Async 2E There is a blocked pool volume. Async 2E External volumes whose cache modes are different are included. CMDRJE Executing 2E The POOL Name is duplicated with another pool. Async 2E The pool cannot include volumes in different RAID levels because the pool cannot include those volumes. Or the pool cannot include the RAID 1 volumes and the volumes of other RAID levels together. Async 2E The pool cannot include both internal volumes and external volumes because the pool is not set to Mixable. Async 2E The usage capacity exceeds the license capacity of program product. CMDRJE Executing 2EE7 00EE The command cannot be accepted. After a while, execute the same command. CMDRJE Executing Async 2EE7 FEEC An internal error occurred. Call Hitachi Data Systems Support Center. Table 9-45 SSB codes that are returned by raidcom modify rcu command raidcom modify rcu Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E CU# of RCU exceed the effective value. CMDRJE Executing 2E The value of least path number is invalid. CMDRJE Executing 2E The value of RIO MIH time is invalid. CMDRJE Executing 2E The value of Round-trip response time is invalid. CMDRJE Executing 2E Invalid product ID or path registration ID. Troubleshooting 9 77

360 raidcom modify rcu Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E Incident that is created by CU is not in the one of followings. - Incident that is sent to MCU host and RCU. - Incident that is sent to RCU. Async 2E Command cannot be executed because the parameter of specified RCU is invalid. Async 2E Command cannot be executed because all the CU numbers in the RCU is not unified at the path that is specified creation or deletion. CMDRJE Executing 2E The CU number is out of effective range. CMDRJE Executing 2E The operation cannot be done because the microcode is being changed. CMDRJE Executing 2E The serial number, the product ID, or the SSID of the target storage system is incorrect. CMDRJE Executing 2E The attribute of the RCU cannot be changed because the specified RCU is not registered. Async 2E The specified CU number is not defined, or an LDEV is not defined under the CU number. CMDRJE Executing 2E The operation cannot be done because the number of paths becomes less than the least path number. Async 2E Command cannot be executed because the RCU identification code of a path is invalid. CMDRJE Executing 2ED6 00EF An internal error occurred. Call Hitachi Data Systems Support Center. CMDRJE Executing 2ED The value of SSID for the remote storage system is invalid. Table 9-46 SSB codes that are returned by raidcom delete rcu_path command raidcom delete rcu_path Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The CU# of RCU exceeds the effective value. CMDRJE Executing 2E The product ID or the path registration ID is invalid. Async 2E Command cannot be executed because the parameter of specified RCU is invalid. CMDRJE Executing 2E The specified port # on the side of RCU is invalid. CMDRJE Executing/ Async 2E The CU number is out of effective range Troubleshooting

361 raidcom delete rcu_path Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing /Async 2E The value of specified port is invalid. Async 2E Failed to establish a path or the deletion operation. The following factor can be thought. Input parameter is invalid. Port status or the MP Blade status is in the state of abnormal. Cable is not connected correctly. Port is specified incorrectly. Async 2E The operation cannot be done because the microcode is being changed. CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command. Async 2E A logical path cannot be deleted because the specified RCU is not registered. Async 2E The specified CU number is not defined, or an LDEV is not defined under the CU number. Async 2E The operation cannot be done because the number of paths becomes less than the least path number. CMDRJE Executing 2E30 840A The port attribute is not Initiator (MCU). Async 2E Command cannot be executed because the RCU identification code of a path is invalid. Async 2E Command cannot be executed because the serial number is not unified in the specified path. CMDRJE Executing 2ED6 00EE The command cannot be accepted because the DKC is busy. After a while, execute the same command. Async 2ED An internal error occurred. Call Hitachi Data Systems Support Center. CMDRJE Executing 2EF The specified parameter is invalid. Check the Command Control Interface Command Reference. Table 9-47 SSB codes that are returned by raidcom add rcu_path command raidcom add rcu_path Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E CU# of RCU exceeds the effective value. CMDRJE Executing 2E Invalid product ID or path registration ID. Async 2E Command cannot be executed because the parameter of specified RCU is invalid. Troubleshooting 9 79

362 raidcom add rcu_path Error message Executing / Async Error code SSB1 SSB2 Description Async 2E Command cannot be executed because all the CU numbers in the RCU is not unified at the path that is specified creation or deletion. CMDRJE Executing 2E The value of port # on the side of RCU is invalid. CMDRJE Executing /Async 2E The CU number is out of effective range. CMDRJE Executing /Async 2E The value of specified port is invalid. Async 2E Failed to establish a path or the deletion operation. The following factor can be thought. Input parameter is invalid. Port status or the MP Blade status is in the state of abnormal. Cable is not connected correctly. Port is specified incorrectly. Async 2E The operation cannot be done because the microcode is being changed. CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command. Async 2E The serial number, the product ID, or the SSID of the target storage system is incorrect. Async 2E A logical path cannot be added because the specified RCU is not registered. Async 2E The specified CU number is not defined, or an LDEV is not defined under the CU number. Async 2E An RCU path cannot be added because the number of valid paths exceeds the maximum. Async 2E The operation cannot be done because the number of paths becomes less than the least path number. CMDRJE Executing 2E30 840A The port attribute is not Initiator (MCU). Async 2E Command cannot be executed because the RCU identification code of a path is invalid. Async 2E Command cannot be executed because the serial number is not unified in the specified path. CMDRJE Executing 2ED6 00EE The command cannot be accepted because the DKC is busy. After a while, execute the same command. Async 2ED An internal error occurred. Call Hitachi Data Systems Support Center. CMDRJE Executing 2ED The value of SSID on the remote storage system is invalid Troubleshooting

363 raidcom add rcu_path Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2EF The specified parameter is invalid. Check the Command Control Interface Command Reference. Table 9-48 SSB codes that are returned by raidcom delete rcu command raidcom delete rcu Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E CU# on the RCU exceeds the effective range. CMDRJE Executing 2E Invalid product ID or path registration ID. Async 2E Command cannot be executed because the parameter of specified RCU is invalid. CMDRJE Executing 2E The value of specified port# on the side of RCU is invalid. Async 2E The CU number is out of effective range. CMDRJE Executing /Async 2E The value of specified port is invalid. Async 2E The operation cannot be done because the microcode is being changed. CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command. Async 2E The serial number, the product ID, or the SSID of the target storage system is incorrect. Async 2E The specified RCU cannot be deleted because the RCU is not registered. Async 2E The specified CU number is not defined, or an LDEV is not defined under the CU number. Async 2E Path cannot be deleted because there is a pair of TrueCopy/Universal Replicator, or a journal volume is in the relevant CU. Async 2E Command cannot be executed because the RCU identification code of a path is invalid. CMDRJE Executing 2ED6 00EE The command cannot be accepted because the DKC is busy. After a while, execute the same command. Async 2ED An internal error occurred. Call Hitachi Data Systems Support Center. CMDRJE Executing 2ED The value of SSID on the remote storage system is invalid. CMDRJE Executing 2EDE 00D1 RCU storage system does not exist. Troubleshooting 9 81

364 raidcom delete rcu Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2EF The specified parameter is invalid. Check the Command Control Interface Command Reference. Table 9-49 SSB codes that are returned by raidcom add rcu command raidcom add rcu Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The value of CU# on the RCU exceeds the effective range. CMDRJE Executing 2E Invalid product ID or path registration ID. Async 2E Command cannot be executed because the parameter of specified RCU is invalid. Async 2E Command cannot be executed because all the CU numbers in the RCU is not unified at the path that is specified creation or deletion. CMDRJE Executing 2E The value of port# on the side of RCU is invalid. CMDRJE Executing /Async 2E The CU number is out of effective range. CMDRJE Executing /Async 2E The value of specified port is invalid. Async 2E Failed to establish a path or the deletion operation. The following factor can be thought. Input parameter is invalid. Port status or the MP Blade status is in the state of abnormal. Cable is not connected correctly. Port is specified incorrectly. Async 2E The operation cannot be done because the microcode is being changed. CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command. Async 2E The serial number, the product ID, or the SSID of the target storage system is incorrect. Async 2E The specified CU number is not defined, or an LDEV is not defined under the CU number. Async 2E The specified RCU is already registered to another product ID Troubleshooting

365 raidcom add rcu Error message Executing / Async Error code SSB1 SSB2 Description Async 2E The operation cannot be performed due to one of the following reasons: The number of RCUs registered in MCU or RCU is more than four. The number of RCUs registered in the system is more than 64 in the case of specifying the cu free. Async 2E The specified SSID is already registered to another RCU. Async 2E The specified RCU is cannot be registered because there is no free RCU. Async 2E The operation cannot be done because the number of paths becomes less than the least path number. CMDRJE Executing 2E30 840A The port attribute is not Initiator (MCU). Async 2E Command cannot be executed because the RCU identification code of a path is invalid. Async 2E The operation cannot be performed because the remote storage system does not support the path between CUs. Async 2E Command cannot be executed because the serial number is not unified in the specified path. CMDRJE Executing 2ED6 00EE The command cannot be accepted because the DKC is busy. After a while, execute the same command. Async 2ED An internal error occurred. Call Hitachi Data Systems Support Center. CMDRJE Executing 2ED The value of SSID on the remote storage system is invalid. CMDRJE Executing 2EF The specified parameter is invalid. Check the Command Control Interface Command Reference. Table 9-50 SSB codes that are returned by raidcom delete ldev command raidcom delete ldev Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E It exceeds the range of LDEV number. Async 2E00 000E This command does not support the emulation type of the specified LDEV. Troubleshooting 9 83

366 raidcom delete ldev Error message Executing / Async Error code SSB1 SSB2 Description Async 2E The specified LDEV is used as a pair of ShadowImage/Thin Image/Copy-on-Write Snapshot/Volume Migration or a relationship of Compatible FlashCopy V2/Compatible Software for IBM FlashCopy SE. Async 2E The specified LDEV is used as a TrueCopy pair, a Universal Replicator pair or a command device defined by Business Continuity Manager. Async 2E The specified LDEV is used as a Universal Replicator pair or a journal. Async 2E The specified LDEV is used as a Compatible FlashCopy V2 relationship. Async 2E The specified LDEV is used as a Thin Image or Copy-on-Write Snapshot pair. Async 2E The specified LDEV is used as a Volume Migration. Async 2E The specified LDEV is used as a system disk. Async 2E The specified LDEV is used as a CC/XRC attribute device. Async 2E The specified LDEV is used as the primary volume for the GAD pair. Async 2E The specified LDEV is used as the secondary volume for the GAD pair. Async 2E An LDEV that is in the state of formatting is included in the parity group of the target LDEV. Async 2E An LDEV that is in the state of executing quick format is included in the parity group of the target LDEV. CMDRJE Executing 2E The specified LDEV is used in another operation. Async 2E The parity group of the target LDEV is in the state of correction copy. CMDRJE Executing 2E The parity group or the external volume group that the specified LDEV is belongs to is used in another operation. Async 2E The operation of Dynamic Provisioning V-VOL cannot be done because there is a blocked pool. Async 2E The operation cannot be done because the internal processing is in progress. CMDRJE Executing 2E The storage system is in internal process, or the configuration changing processes are conflicting. Async 2E The operation cannot be done because there is blocked part in the system. CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command Troubleshooting

367 raidcom delete ldev Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing Async 2E LDEV is not installed. CMDRJE Executing 2E An LU path has been defined. CMDRJE Async 2E30 000A The specified LDEV is used as a Dynamic Provisioning. Async 2E30 000C The specified LDEV is used as a quorum disk. Async 2E30 000E The specified LDEV is used as a pool volume. Async 2E30 000F The specified LDEV is used as a journal volume. Async 2E The specified LDEV is used in the FICON Data Migration. Async 2E The specified LDEV is a command device. Executing Async 2E The specified volume cannot be deleted because it is a LUSE volume. Async 2E This is a volume that the Data Retention Utility is set. Async 2E30 001A Volume Security is set to the specified LDEV. Async 2E30 001E The specified LDEV cannot be deleted because of online from the mainframe host. Async 2E30 004E The specified LDEV is a Data Retention Utility/ Volume Retention Manager attribute device. Async 2E This is a volume that the Volume Retention Manager is set. Async 2E The specified LDEV is used as a Compatible FlashCopy V2 or a Compatible Software for IBM FlashCopy SE relationship. Async 2E The specified LDEV is used as a Volume Migration. Async 2E The specified LDEV is used as a Volume Migration Async 2E The specified LDEV is used as a system disk. Async 2E The specified LDEV is used as a system disk. Async 2E The specified LDEV is a command device. Troubleshooting 9 85

368 raidcom delete ldev Error message Executing / Async Error code SSB1 SSB2 Description Async 2E The specified LDEV cannot be operated because it is an external volume mapped for online data migration. Async 2E The specified volume is used as a TrueCopy. Async 2E The specified volume is used as a TrueCopy. Async 2E The specified volume is used as a ShadowImage. Async 2E The specified volume is used as a ShadowImage. Async 2E The specified volume is used as a ShadowImage. Async 2E The specified LDEV is used as a reserved volume of Volume Migration. Async 2E The target LDEV is a quorum disk and cannot be deleted. CMDRJE Executing 2EE8 00EE The command cannot be accepted. After a while, execute the same command. Async 2EE8 0A18 An internal error occurred. CMDRJE Executing Async 2EE8 FEEC An internal error occurred. Call Hitachi Data Systems Support Center. Async 2EE8 FFFB An internal error occurred. Call Hitachi Data Systems Support Center. Table 9-51 SSB codes that are returned by raidcom delete hba_wwn command raidcom delete hba_wwn Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B F The program product is not installed. CMDRJE Executing B The host group ID exceeds the maximum value. CMDRJE Executing B The specified host group is not installed. CMDRJE Executing B A The attribute of specified port is Initiator or External Troubleshooting

369 Table 9-52 SSB codes that are returned by raidcom add hba_wwn command raidcom add hba_wwn Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B F The program product is not installed. CMDRJE Executing B The value of hba_wwn is invalid. CMDRJE Executing B The value of host group ID exceeds the maximum. CMDRJE Executing B The host group is not installed. CMDRJE Executing B A The attribute of specified port is Initiator or External. CMDRJE Executing B The number of WWN reached the maximum. CMDRJE Executing B HBA WWN is already registered. Table 9-53 SSB codes that are returned by raidcom set hba_wwn command raidcom set hba_wwn Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B F The program product is not installed. CMDRJE Executing B The value of host group ID exceeds the maximum. CMDRJE Executing B The host group is not installed. CMDRJE Executing B A The attribute of specified port is Initiator or External. CMDRJE Executing B The specified WWN does not exist. CMDRJE Executing B B The specified WWN nickname is already used in the same port. Table 9-54 SSB codes that are returned by raidcom reset hba_wwn command raidcom reset hba_wwn Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B F The program product is not installed. CMDRJE Executing B The value of Host group ID exceeds the maximum. CMDRJE Executing B The host group is not installed. CMDRJE Executing B A The attribute of the specified port is Initiator or External. CMDRJE Executing B The specified WWN does not exists. Troubleshooting 9 87

370 Table 9-55 SSB codes that are returned by raidcom add copy_grp command raidcom add copy_grp Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E00 000B The number of MU# exceeds the maximum. CMDRJE Executing 2E Invalid device number. CMDRJE Executing 2E The specified journal ID exceeds the range. CMDRJE Executing 2E A device group is not installed. CMDRJE Executing 2E There is a copy group. CMDRJE Executing 2E The number of copy groups in the system reached the maximum. CMDRJE Executing 2E The specified device group is already defined in the other copy group. CMDRJE Executing 2E There is an LDEV in the device group that has an undefined device name. CMDRJE Executing 2E The same device names of LDEV are in the device group. CMDRJE Executing 2E The same LDEVs are in the copy group. Invalid Character Executing - - Unavailable character is included in the name of copy group. Table 9-56 SSB codes that are returned by raidcom delete copy_grp command raidcom delete copy_grp Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The copy group is not installed. Invalid Character Executing - - Unavailable character is included in the name of copy group. Table 9-57 SSB codes that are returned by raidcom modify port -port_speed command raidcom modify port -port_speed Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B C The specified AL-PA is invalid. CMDRJE Executing B E The specified topology is invalid. CMDRJE Executing B955 05A6 The other than "fabric on" cannot be specified when specifying a topology of the package for Fibre Channel over Ethernet. CMDRJE Executing B955 05A7 The other than "P-to-P (point to point)" cannot be specified when specifying a topology of the package for Fibre Channel over Ethernet Troubleshooting

371 raidcom modify port -port_speed Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B The command device being used at the local CCI exists under the port. CMDRJE Executing B F The program product is not installed. CMDRJE Executing B D Invalid host speed is set for 4Gbps fibre adapter. The available host speeds are AUTO, 1G, 2G, and 4G only. CMDRJE Executing B F Invalid host speed is set for 8Gbps Fibre Adapter. The available host speeds are AUTO, 2G, 4G, and 8G only. CMDRJE Executing B955 11A5 The other than "10G" cannot be specified when specifying a host speed of the package for Fibre Channel over Ethernet. CMDRJE Executing B955 11AE Invalid host speed is set for 16Gbps Fibre Adapter. The available host speeds are AUTO, 2G, 4G, and 8G only. CMDRJE Executing B955 12AF Topology FC-AL and 16G as the host speed are not supported for the 16Gbps fibre adapter. Table 9-58 SSB codes that are returned by raidcom modify port -port_attribute command raidcom modify port -port_attribute Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E Invalid package CMDRJE Executing 2E The operation cannot be done because another application, for example Device Manager - Storage Navigator and SVP, is used. CMDRJE Executing 2E The specified port is blocked. CMDRJE Executing 2E There is a pair for TrueCopy/Universal Replicator that is used the specified port. CMDRJE Executing 2E There is a pair for TrueCopy/Universal Replicator that is used the specified port. CMDRJE Executing 2E11 800D The storage system is in the state of start-up. Wait for a while, then retry the operation. CMDRJE Executing 2E The specified port is not installed. CMDRJE Executing 2E There is a path for TrueCopy/Universal Replicator in the specified port. CMDRJE Executing 2E There is an external VOL path in the specified port. CMDRJE Executing 2E There is a path for TrueCopy/Universal Replicator in the specified port. CMDRJE Executing 2E There is a path for TrueCopy/Universal Replicator in the specified port. Troubleshooting 9 89

372 raidcom modify port -port_attribute Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E An LU path has been defined. CMDRJE Executing 2ED0 84FC An internal error occurred. Call Hitachi Data Systems Support Center. Table 9-59 SSB codes that are returned by raidcom delete host_grp command raidcom delete host_grp Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B C The cancelling of the host mode option 61 setting was aborted. CMDRJE Executing B F The program product is not installed. CMDRJE Executing B The value of host group ID exceeds the maximum. CMDRJE Executing B The attribute of the specified port is Initiator or External. CMDRJE Executing B Deletion cannot be executed because the last path of ShadowImage is included in the host group. CMDRJE Executing B A Deletion cannot be executed because the last path of Thin Image or Copy-on-Write Snapshot is included in the host group. CMDRJE Executing B The command device being used at the local CCI exists under the host group. Table 9-60 SSB codes that are returned by raidcom add host_grp command raidcom add host_grp Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B F The program product is not installed. CMDRJE Executing B The value of host group ID exceeds the maximum. CMDRJE Executing B The attribute of the specified port is Initiator or External. CMDRJE Executing B The same host group name is already installed in the specified port. CMDRJE Executing B The default host group name cannot be registered for the host group ID is other than Troubleshooting

373 Table 9-61 SSB codes that are returned by raidcom modify host_grp command raidcom modify host_grp Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B The command device being used at the local CCI exists under the host group. CMDRJE Executing B Changing of the host mode/ host mode option cannot be executed for the port of Initiator or External. CMDRJE Executing B The invalid host mode is specified. CMDRJE Executing B C The cancelling of the host mode option 61 setting was aborted. CMDRJE Executing B The host group ID exceeds the maximum. CMDRJE Executing B The program product is not installed. CMDRJE Executing B The specified host group is not installed. CMDRJE Executing B9F9 B9F9 The command device being used at the local CCI exists under the host group. Table 9-62 SSB codes that are returned by raidcom disconnect path command raidcom disconnect path Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The path group is out of the enabled range. CMDRJE Executing 2E The value of specified port is invalid. Async 2E The specified external path has already disconnected the path, or is in the process of checking path. Async 2E11 001B The target LDEV is blocked. Async 2E The path for the specified external path is in the state of disconnected. Async 2E This command cannot be operated due to one of the following reasons: All the paths to the external volumes are blocked. There will be no normal paths. CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command. CMDRJE CMDRJE Executing/ Async Executing/ Async 2E There is no specified external volume. 2E There is no connection path to an external volume. Troubleshooting 9 91

374 raidcom disconnect path Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E WWN is not registered. CMDRJE Executing 2E There is no path group. CMDRJE Executing 2E external_wwn is not defined. Async 2E30 001E Online from the mainframe host. CMDRJE Executing 2E The attribute of a port is not External(ELUN). CMDRJE Executing 2EDA 00EE The command cannot be accepted. After a while, execute the same command. Async 2EDA 0905 An internal error occurred by the operation of a path for an external path. Call Hitachi Data Systems Support Center. Table 9-63 SSB codes that are returned by raidcom delete path command raidcom delete path Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The path group is not in a effective range. CMDRJE Executing 2E The value of the specified port is incorrect. Async 2E The path operations cannot be performed for the following reasons: The target of the specified path group is TagmaStore USP/TagmaStore NSC. The specified path group contains the external volume that is set the reserve attribute from the host. Async 2E The operation cannot continue because the microcode is being replaced. CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command. CMDRJE Executing 2E There is no external volume group. CMDRJE Executing 2E There is no external connection path. CMDRJE Executing 2E WWN is not registered. CMDRJE Executing /Async 2E There is no path group. CMDRJE Executing /Async 2E Paths cannot be deleted because there are no normal paths. CMDRJE Executing 2E The port attribute is not External (ELUN). CMDRJE Executing 2EDA 00EE The command cannot be accepted. After a while, execute the same command Troubleshooting

375 raidcom delete path Error message Executing / Async Error code SSB1 SSB2 Description Async 2EDA FEEC An internal error occurred. Call Hitachi Data Systems Support Center. Async 2EDA FFFF An internal error occurred. Call Hitachi Data Systems Support Center. Table 9-64 SSB codes that are returned by raidcom add path command raidcom add path Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The path group is not in the enabled range. CMDRJE Executing 2E The value of specified port is incorrect. Async 2E The path operations cannot be performed for the following reasons: The target of the specified path group is TagmaStore USP/TagmaStore NSC. The specified path group contains the external volume that is set the reserve attribute from the host. Async 2E The WWN on the side of specified external storage is not connected to an External port. This message may be output if the migration source storage system is USP V/VM and the host mode option 2 is not set to the port that connects to the migration target storage system. Async 2E The operation cannot continue because the microcode is being replaced. CMDRJE Executing 2E The command cannot be accepted. After a while, execute the same command. CMDRJE Executing 2E There is no external volume group. Async 2E Invalid WWN. CMDRJE Executing /Async 2E There is no path group. CMDRJE Executing/ Async 2E The same path has been defined already. Async 2E The operation cannot be done because the number of path in the path group exceeds 8. CMDRJE Executing 2E The attribute of a port is not External (ELUN). Async 2E The specified external storage LU is the device of not supported. Troubleshooting 9 93

376 raidcom add path Error message Executing / Async Error code SSB1 SSB2 Description Async 2E The specified external storage system is not supported. CMDRJE Executing 2EDA 00EE The command cannot be accepted. After a while, execute the same command. Async 2EDA FEEC An internal error occurred. Call Hitachi Data Systems Support Center. Async 2EDA FFFF An internal error occurred. Call Hitachi Data Systems Support Center. Table 9-65 SSB codes that are returned by raidcom -logout command raidcom -logout Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E Failed to release the resource lock. Table 9-66 SSB codes that are returned by raidcom monitor pool command raidcom monitor pool Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The value of pool ID is out of range. CMDRJE Executing 2E Monitor cannot be started because the performance monitor is in the collecting status. CMDRJE Executing 2E Monitor cannot be stopped because the performance monitor is stopped. CMDRJE Executing 2E Monitor cannot start because the performance monitor is in use. Retry the operation after completing or stopping the reallocation of Tier. CMDRJE Executing 2E There is not enough time after collecting performance monitor. CMDRJE Executing 2E The pool is not in the state of specifying the performance monitor to start or stop. CMDRJE Executing 2E The pool ID is not installed. CMDRJE Executing 2E A SM for Dynamic Provisioning is not installed. CMDRJE Executing 2E A SM for Dynamic Tiering is not installed. CMDRJE Executing 2E The program product of Dynamic Tiering is not installed. CMDRJE Executing 2E Start or stop of performance monitor by hand cannot be done because it is a pool for Dynamic Provisioning or it is automatic execution mode Troubleshooting

377 raidcom monitor pool Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The specified pool is the one for Thin Image or Copy-on-Write Snapshot. CMDRJE Executing 2EE7 FEEC An internal error occurred. Call Hitachi Data Systems Support Center. Table 9-67 SSB codes that are returned by raidcom reallocate pool command raidcom reallocate pool Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The value of pool ID is out of range. CMDRJE Executing 2E There is not enough time after collecting performance monitor. CMDRJE Executing 2E Tier Reallocation cannot be started because the state of performance monitor information is not enabled. Start the performance monitor again. CMDRJE Executing 2E Reallocation cannot be started because it is reallocating. CMDRJE Executing 2E10 600A Reallocation cannot be stopped because it is not reallocating. CMDRJE Executing 2E The operation cannot be done because it is being discarded pages. CMDRJE Executing 2E The operation cannot be done because the Tier is being deterred reallocation. CMDRJE Executing 2E The pool is not in the status of specifying the reallocation to start or stop. CMDRJE Executing 2E The pool ID is not installed. CMDRJE Executing 2E A SM for Dynamic Provisioning is not installed. CMDRJE Executing 2E A SM for Dynamic Tiering is not installed. CMDRJE Executing 2E The program product of Dynamic Tiering is not installed. CMDRJE Executing 2E Start or stop of performance monitor by hand cannot be done because it is a pool for Dynamic Provisioning or it is automatic execution mode. CMDRJE Executing 2E The specified pool is the one for Thin Image or Copy-on-Write Snapshot. CMDRJE Executing 2E Reallocation cannot be done because there is only one Tier in the pool group. CMDRJE Executing 2EE7 FEEC An internal error occurred. Call Hitachi Data Systems Support Center. Troubleshooting 9 95

378 Table 9-68 SSB codes that are returned by raidcom extend ldev command raidcom extend ldev Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B96B 0B27 The command cannot be operated because the virtual LDEV is not defined yet. CMDRJE Executing - - See the troubleshooting topics in the Provisioning Guide for the storage system. Table 9-69 SSB codes that are returned by raidcom delete resource command raidcom delete resource Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The specified resource group cannot be operated. CMDRJE Executing 2E Resource groups cannot be deleted because the resource groups are locked. CMDRJE Executing 2E The LDEV and the host group cannot be set to the different virtual storage machine. CMDRJE Executing 2E There is no parity group. CMDRJE Executing 2E A resource group cannot be deleted because the specified resource group is undefined. CMDRJE Executing 2E There is no external volume group. CMDRJE Executing 2E The information for the virtual storage machine is set in the specified resource. CMDRJE Executing 2E A resource group cannot be deleted because a resource belongs to the specified resource group. CMDRJE Executing 2E A resource cannot be deleted from the resource group because the specified LDEV number is not the top LDEV number in the LUSE volume. CMDRJE Executing 2E The operation to resource group 0 (meta_resource) cannot be performed. CMDRJE Executing 2ECA FEEC An internal error occurred. Call Hitachi Data Systems Support Center. Table 9-70 SSB codes that are returned by raidcom add resource command raidcom add resource Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The specified resource group name is against the naming rules. CMDRJE Executing 2E The specified resource group cannot be operated Troubleshooting

379 raidcom add resource Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The resource ID and the sub-resource ID are out of the effective range. CMDRJE Executing 2E The machine type is invalid. CMDRJE Executing 2E The serial number is invalid. CMDRJE Executing 2E The value of specified port is invalid. CMDRJE Executing 2E The LDEV and the host group cannot be set to the different virtual storage machine. CMDRJE Executing 2E There is no parity group. CMDRJE Executing 2E You cannot execute this command because of either reason below. A resource cannot be added to the resource group because the specified resource group is undefined. A resource group name cannot be changed because the specified resource group is undefined. CMDRJE Executing 2E There is no external volume group. CMDRJE Executing 2E21 900D The program products of Resource Partition Manager are not installed. CMDRJE Executing 2E The information for the virtual storage machine is set in the specified resource. CMDRJE Executing 2E You cannot execute this command because of either reason below. A resource group cannot be created because the specified resource group name is duplicated. A resource group name cannot be changed because the specified resource group name is duplicated. CMDRJE Executing 2E A resource cannot be added to a resource group because the specified resource belongs to the resource group. CMDRJE Executing 2E A resource cannot be added to the resource group because the specified LDEV number is not the top LDEV number in the LUSE volume. CMDRJE Executing 2E Any more resource groups cannot be created because the registered number of resource groups has reached the maximum. CMDRJE Executing 2E A virtual storage machine cannot be created because the number of registered virtual storage machines has reached the maximum. CMDRJE Executing 2E The operation to resource group 0 (meta_resource) cannot be performed. CMDRJE Executing 2ECA FEEC An internal error occurred. Call Hitachi Data Systems Support Center. Troubleshooting 9 97

380 Table 9-71 SSB codes that are returned by raidcom get resource command raidcom get resource Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2EF0 FEEC An internal error occurred. Call Hitachi Data Systems Support Center. Table 9-72 SSB codes that are returned by raidcom map resource command raidcom map resource Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The specified LDEV number or the LDEV number for the virtual volume is out of the range. CMDRJE Executing 2E SSID is not with in the valid range. CMDRJE Executing 2E00 000E The specified emulation type of the LDEV is not supported in this command. CMDRJE Executing 2E00 002B The specified attribute of the virtual LDEV is not supported. CMDRJE Executing 2E00 002C The specified attribute of the virtual LDEV is invalid. CMDRJE Executing 2E You cannot execute the command because a parameter required for the virtualization was not specified. CMDRJE Executing 2E The specified emulation type is invalid. CMDRJE Executing 2E The specified LDEV cannot be operated because it belongs to the default virtual storage machine. CMDRJE Executing 2E The specified volume cannot be operated because the LDEV number of the specified volume does not match the LDEV number of the virtual volume. CMDRJE Executing 2E You cannot execute the command because the processing by the other software (Device Manager - Storage Navigator or SVP, and so on) is in progress. CMDRJE Executing 2E The information of the virtual storage machine is already set in the specified resource. CMDRJE Executing 2E The specified virtual LDEV number is already exist in the virtual storage machine to which the specified LDEV belongs. CMDRJE Executing 2E You cannot operate the LDEV that has the LU path definition. CMDRJE Executing 2E The specified LDEV is already defined. CMDRJE Executing 2E The specified volume cannot be set because it is a LUSE volume Troubleshooting

381 raidcom map resource Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The specified LDEV cannot be operated because it has an attribute. CMDRJE Executing 2E30 008C The specified LDEV cannot be set the information of the virtual volume because it is not virtualized. CMDRJE Executing 2ECA FEEC An internal error occurred. Call Hitachi Data Systems Support Center. CMDRJE Executing 2EF The specified operation cannot be performed because it is not supported. Table 9-73 SSB codes that are returned by raidcom unmap resource command raidcom unmap resource Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The specified LDEV number or the LDEV number for the virtual volume is out of the range. CMDRJE Executing 2E10 004F The specified LDEV for the virtual storage machine is not defined in the specified LDEV. CMDRJE Executing 2E10 005E The specified LDEV is used by the TrueCopy pair or the Universal Replicator pair. CMDRJE Executing 2E You cannot execute the command because the processing by the other software (Device Manager - Storage Navigator or SVP, and so on) is in progress. CMDRJE Executing 2E The Resource Partition Manager is not installed. CMDRJE Executing 2E The information of the virtual storage machine is not set in the specified resource. CMDRJE Executing 2E You cannot operate the LDEV that has the LU path definition. CMDRJE Executing 2E30 000C The specified LDEV is used as a quorum disk. CMDRJE Executing 2E30 008B The specified LDEV cannot be operated because it is the external volume for the online data migration. CMDRJE Executing 2E30 008D The specified volume cannot be operated because it is the mainframe volume. CMDRJE Executing 2ECA FEEC An internal error occurred. Call Hitachi Data Systems Support Center. CMDRJE Executing 2EF The specified operation cannot be performed because it is not supported. Troubleshooting 9 99

382 Table 9-74 SSB codes that are returned by raidcom modify resource command raidcom modify resource Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2EF The specified operation cannot be performed because it is not supported. Table 9-75 SSB codes that are returned by raidcom set resource command raidcom set resource Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2EF The specified operation cannot be performed because it is not supported. Table 9-76 SSB codes that are returned by raidcom reset resource command raidcom reset resource Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2EF The specified operation cannot be performed because it is not supported. Table 9-77 SSB codes that are returned by raidcom unlock resource command raidcom unlock resource Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E Cannot unlock because it is locked in another session. Table 9-78 SSB codes that are returned by raidcom modify clpr command raidcom modify clpr Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E It exceeds the settable range of LDEV numbers. CMDRJE Executing 2E00 002A The specified LDEV is not subject to processing. CMDRJE Executing 2E The parity group number or the external volume group number is not in the effective range. CMDRJE Executing 2E The specified group type is not correct. CMDRJE Executing 2E The combined parity group cannot be set across multiple CLPRs Troubleshooting

383 raidcom modify clpr Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing 2E The item cannot be migrated to another CLPR because of either reason below. The specified parity group or external volume group has an LUSE volume. The specified volume is an LUSE volume. CMDRJE Executing 2E The specified CLPR number is invalid. CMDRJE Executing 2E11 810A Abnormal cache status. CMDRJE Executing 2E The CLPR cannot be migrated because the specified parity group or the external volume group includes the pool volume that is used in the pool for Thin Image or Copy-on-Write Snapshot. CMDRJE Executing 2E LDEV is not installed. CMDRJE Executing 2E There is no parity group. CMDRJE Executing 2E There is no external volume group. CMDRJE Executing 2E The specified CLPR is not installed. CMDRJE Executing 2E CLPR cannot be transferred by either one of the following two reasons. Cache Residency Manager is set for the specified volume. The specified parity group includes the volumes for which Cache Residency Manager are set. CMDRJE Executing 2E30 000F The specified LDEV is used as a journal volume. CMDRJE Executing 2E The specified parity group includes HDEV with the journal attribute. CMDRJE Executing 2EE8 00F0 The specified command cannot be accepted because the command is not supported. CMDRJE Executing 2EE8 FEEC An internal error occurred. Call Hitachi Data Systems Support Center. CMDRJE Executing 2EF The specified parameter is invalid. Check the Command Control Interface Command Reference. CMDRJE Executing 2EF3 9F02 The specified operation cannot be performed because it is not supported. CMDRJE Executing 2EF6 FEEC An internal error occurred. Call Hitachi Data Systems Support Center. Troubleshooting 9 101

384 Table 9-79 SSB codes that are returned by raidcom add spm_group command raidcom add spm_group Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B9D4 B9D0 Server Priority Manager is being used by Device Manager - Storage Navigator. CMDRJE Executing B9D4 B9D4 Server Priority Manager program product is not installed. CMDRJE Executing B9D4 B9D6 The number of Server Priority Manager groups exceeds the maximum. Table 9-80 SSB codes that are returned by raidcom delete spm_group command raidcom delete spm_group Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B9D4 B9D0 Server Priority Manager is being used by Device Manager - Storage Navigator. CMDRJE Executing B9D4 B9D2 The specified WWN or nickname does not exist. CMDRJE Executing B9D4 B9D4 Server Priority Manager program product is not installed. Table 9-81 SSB codes that are returned by raidcom modify spm_group command raidcom modify spm_group Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B9D4 B9D0 Server Priority Manager is being used by Device Manager - Storage Navigator. CMDRJE Executing B9D4 B9D4 Server Priority Manager program product is not installed. Table 9-82 SSB codes that are returned by raidcom add spm_wwn command raidcom add spm_wwn Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B9D4 B9D0 Server Priority Manager is being used by Device Manager - Storage Navigator. CMDRJE Executing B9D4 B9D2 The specified WWN does not exist. CMDRJE Executing B9D4 B9D4 Server Priority Manager program product is not installed. CMDRJE Executing B9D4 B9D7 The specified SPM name has already existed Troubleshooting

385 Table 9-83 SSB codes that are returned by raidcom delete spm_wwn command raidcom delete spm_wwn Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B9D4 B9D0 Server Priority Manager is being used by Device Manager - Storage Navigator. CMDRJE Executing B9D4 B9D2 The configuration WWN or nickname does not exist. CMDRJE Executing B9D4 B9D4 Server Priority Manager program product is not installed. Table 9-84 SSB codes that are returned by raidcom modify spm_wwn command raidcom modify spm_wwn Error message Executing / Async Error code SSB1 SSB2 Description CMDRJE Executing B9D4 B9D0 Server Priority Manager is being used by Device Manager - Storage Navigator. CMDRJE Executing B9D4 B9D1 The number of WWNs exceeds the maximum that can be set in the system. CMDRJE Executing B9D4 B9D4 Server Priority Manager program product is not installed. CMDRJE Executing B9D4 B9D5 The number of WWNs exceeds the maximum that can be set to the port. Calling the HDS Support Center If you need to contact the Hitachi Data Systems Support Center, please provide as much information about the problem as possible, including: The circumstances surrounding the error or failure. The exact content of any error messages displayed on the host systems. The exact content of any error messages displayed by Storage Navigator. The Storage Navigator configuration information (use the Dump Tool). The data in the CCI error log file and trace data (all files in the HORCM_LOG directory). The service information messages (SIMs), including reference codes and severity levels, displayed by Storage Navigator. The HDS customer support staff is available 24 hours a day, seven days a week. If you need technical support, log on to the HDS Portal for contact information: Troubleshooting 9 103

386 9 104 Troubleshooting

387 Index A alternate command device 2 5 defining 2 6 asynchronous commands list of provisioning 5 4 processing 1 3, 5 3 authorities for commands and operations 3 9 C cascading connections and configuration files 2 26 configuration files 2 29 cascading pairs 6 7 cascading volume pairs definition 2 25 cascading volumes restrictions 6 8 CCI functions 1 2 cluster manager 6 10 command device 2 2 alternate 2 5 guarding 2 3 instance number 2 4 command execution modes 3 15 command parameter, HORCM_CMD 2 16 commands authorities 3 9 error logging for audit 2 39 error messages and troubleshooting 9 8 examples 8 1 execution modes 1 4 in-band execution 3 2 out-of-band execution 3 2 processing asynchronously 5 3 processing synchronously 5 3 configuration check 3 24 configuration definition file 2 12 examples 2 13 configuration definition file settings 2 15, 2 16 cascading connections 2 26, 2 29 cascading volume pairs 2 25 dev_name 2 18 HORCM_DEV 2 20 HORCM_INST 2 22 HORCM_LDEV 2 23 HORCM_LDEVG 2 24 HORCM_MON 2 15 configuration file parameters 2 14 configuration file parameters 2 14 configuration setting commands, raidcom 1 3 consistency groups 6 25 copy groups 3 29 defining 3 35 deleting 3 38 deleting LDEV 3 37 D data protection 1 9 command compatibility 7 9 configuration examples 7 7 defining command device 7 14 environment variables 7 14 facility 7 5 parameters 7 5 permission command 7 10 permitting protected volumes 7 11 specifications 7 6 data protection operations 7 1 data replication operations 6 1 Data Retention Utility how it works 7 2 restrictions on volumes 7 3 Database Validator how it works 7 3 restrictions 7 4 definition file, configuration parameters 2 14 definition file, configuration parameters 2 14 dev_name 2 18 device groups 3 29 definition methods 3 29 deleting 3 34 settings and read operations 3 29 device parameter, HORCM_DEV 2 20 Index 1

388 discovering remote volumes 6 55 dual pathing on Solaris 2 3, 2 17 duplicated mirroring 6 6 E endian little vs big 2 11 environment variables for data protection 7 14 environment variables for log directories 2 38 error codes horctakeover and pair commands:troubleshooting 9 16 raidscan, raidqry, raidar, horcctl:troubleshooting 9 17 troubleshooting 9 6, 9 18 error messages troubleshooting 9 6 examples directory mound for Windows 8 12 GPT disk for Windows 8 11 group version control for mixed storage system configurations 8 2 LDM volume discovery and flushing for Windows 8 2 mountvol attached to Windows 8 5 signature changing facility for Windows 8 9 SLPR configuration 8 18 specify host group 8 14 system buffer flushing 8 6 volume discovery 8 3 external volumes creating 5 39 operations 5 39 F fence level settings 6 31, 6 32 fibre channel failure 6 30 files 2 31 log and trace files 2 35 OpenVMS 2 35 UNIX 2 32 user-created scripts 2 44 Windows 2 33 H HORCM_CMD 2 16 HORCM_DEV 2 20 HORCM_INST 2 22 HORCM_INSTP 2 24, 2 25 HORCM_LDEV 2 23 HORCM_LDEVG 2 24 HORCM_MON 2 15 horcm.conf file 6 45 host components 2 9 and pairing 2 11 HORCM 2 9 instance configurations 2 9 host group check 3 22 I in-band command execution 3 2 in-system replication 1 8 instance number 2 4 instance parameter, HORCM_INST 2 22 internal volumes creating 5 19, 5 20 operations 5 19 L LDEV adding 3 32 check 3 17 deleting 3 33 LDEV group function 3 25 LDEV group parameter, HORCM_LDEVG 2 24 LDEV grouping 1 7 LDEV nickname 1 7, 5 5 LDEV parameter, HORCM_LDEV 2 23 line-by-line mode 1 3, 1 4, 3 15, 3 16 log and trace files 2 35 command error logging for audit 2 39 log files 2 36 environment variables for log directories 2 38 names and locations 2 37 logging command errors for audit 2 39 M mirror descriptors and group assignment configuration files 2 25 and volumes 7 7 mirroring duplicated 6 6 monitor parameter, HORCM_MON 2 15 MxN configuration and control 6 44 O OpenVMS files 2 35 starting up one instance 4 4 starting up two instances 4 5 Oracle protection of volume 7 4 restrictions with Database Validator 7 4 out-of-band command execution 3 2 P pairdisplay examples on HOST1 and HOST paired volumes 6 2 parameters, configuration 2 14 permission command and data protection 7 10 port check 3 20 Index 2

389 precheck 1 4 provisioning operations 5 1 R raidcom command configuration setting command 1 3 remote command device defining 2 6 replication 6 44 remote replication 1 8 remote volume discovery 6 55 replication cascading pairs 6 7 cascading volumes 6 8 duplicated mirroring 6 6 in-system 1 8 local system configuration 6 17 operations 6 2, 6 18 pair status 6 19 paired volumes 6 25 remote 1 8 remote system configuration 6 16 requirements 6 3 sidefile cache 6 27 volume status 6 19 resource group locking 1 8 resource lock function 3 14 restrictions cascading volumes 6 8 CCI operations 9 3 Data Retention Utility 7 3 Database Validator 7 4 replication 6 26 Volume Migration 6 43 S script files 2 44 content checking 3 16 SCSI command interface command competition 2 7 command flow 2 8 LDEVs 2 8 SCSI commands 2 6 sidefile 6 28 cache 6 27 SLPR configuration examples 8 18 security 8 16 security:specify SLPR protection facility 8 17 Solaris dual pathing 2 3, 2 17 SSB codes troubleshooting 9 19 starting as a service on Windows 4 6 one instance on OpenVMS 4 4 one instance on UNIX 4 2 one instance on Windows 4 3 two instance on OpenVMS 4 5 two instances on UNIX 4 2 two instances on Windows 4 3 synchronous commands processing 5 3 system log messages troubleshooting 9 6 T takeover commands 6 10 trace control command 2 38 trace files 2 38 trace control command 2 38 transaction mode 1 3, 1 4, 3 15, 3 16 troubleshooting 9 1 command error codes 9 8 error messages and error codes 9 6 general 9 2 generic error codes (horctakeover and pair commands) 9 16, 9 19 generic error codes (raidscan, raidqry, raidar, horcctl) 9 17 notes and restrictions 9 3 specific codes 9 18 system log messages 9 6 U UNIX files 2 32 starting up one instance 4 2 starting up two instances 4 2 user authentication 1 7, 3 6 command operation 3 6 V virtual volumes creating 5 24, 5 34 operations 5 24, 5 32 volume migration commands 6 39 configurations 6 37 controlling 6 37 specifications 6 37 volumes restrictions using Data Retention Utility 7 3 W Windows files 2 33 starting as a service 4 6 starting up one instance 4 3 starting up two instances 4 3 Index 3

390 Index 4

391

392 Hitachi Data Systems Corporate Headquarters 2845 Lafayette Street Santa Clara, California U.S.A. Regional Contact Information Americas Europe, Middle East, and Africa +44 (0) Asia Pacific MK-90RD

Hitachi Virtual Storage Platform

Hitachi Virtual Storage Platform Hitachi Virtual Storage Platform Performance Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-90RD7020-12 2010-2013 Hitachi Ltd. All rights reserved. No part of this

More information

Hitachi Virtual Storage Platform

Hitachi Virtual Storage Platform Hitachi Virtual Storage Platform Encryption License Key User Guide FASTFIND LINKS Contents Product Version Getting Help MK-90RD7015-10 2010-2014 Hitachi, Ltd. All rights reserved. No part of this publication

More information

Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Hitachi Data Retention Utility User s Guide

Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Hitachi Data Retention Utility User s Guide Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Hitachi Data Retention Utility User s Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-96RD612-03

More information

Hitachi Virtual Storage Platform

Hitachi Virtual Storage Platform Hitachi Virtual Storage Platform Hitachi Universal Replicator User Guide FASTFIND LINKS Contents Product Version Getting Help MK-90RD7032-14 2010-2014 Hitachi, Ltd. All rights reserved. No part of this

More information

Hitachi Storage Replication Adapter 2.1 for VMware vcenter Site Recovery Manager 5.1/5.5 Deployment Guide

Hitachi Storage Replication Adapter 2.1 for VMware vcenter Site Recovery Manager 5.1/5.5 Deployment Guide Hitachi Storage Replication Adapter 2.1 for VMware vcenter Site Recovery Manager 5.1/5.5 Deployment FASTFIND LINKS Document conventions Product version Getting help Contents MK-09RM6745-08 2009-2014 Hitachi

More information

Hitachi Command Suite. Dynamic Link Manager. (for Windows ) User Guide. Document Organization. Product Version. Getting Help. Contents MK-92DLM129-30

Hitachi Command Suite. Dynamic Link Manager. (for Windows ) User Guide. Document Organization. Product Version. Getting Help. Contents MK-92DLM129-30 Hitachi Command Suite Dynamic Link Manager (for Windows ) User Guide Document Organization Product Version Getting Help Contents MK-92DLM129-30 2014 Hitachi, Ltd. All rights reserved. No part of this publication

More information

Hitachi Data Ingestor

Hitachi Data Ingestor Hitachi Data Ingestor Backup Restore Features Supplement for Hitachi Data Protection Suite Product Version Getting Help Contents MK-90HDI009-14 2010-2015 Hitachi, Ltd. All rights reserved. No part of this

More information

Hitachi Virtual Storage Platform

Hitachi Virtual Storage Platform Hitachi Virtual Storage Platform Hitachi Storage Navigator User Guide FASTFIND LINKS Contents Product Version Getting Help MK-90RD7027-15 2010-2014 Hitachi, Ltd. All rights reserved. No part of this publication

More information

FASTFIND LINKS. Document Organization Product Version Getting Help Contents MK-96RD617-06

FASTFIND LINKS. Document Organization Product Version Getting Help Contents MK-96RD617-06 Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Hitachi Performance Manager User s Guide Performance Monitor, Volume Migration, and Server Priority Manager FASTFIND LINKS Document

More information

Compute Systems Manager

Compute Systems Manager Hitachi Command Suite Compute Systems Manager Installation and Configuration Guide MK-91HC195-12 2014, 2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted

More information

Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Dynamic Provisioning User s Guide

Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Dynamic Provisioning User s Guide Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Dynamic Provisioning User s Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-96RD641-07 Copyright

More information

Hitachi Command Suite. Tuning Manager. Installation Guide. Document Organization. Product Version. Getting Help. Contents MK-96HC141-27

Hitachi Command Suite. Tuning Manager. Installation Guide. Document Organization. Product Version. Getting Help. Contents MK-96HC141-27 Hitachi Command Suite Tuning Manager Installation Guide Document Organization Product Version Getting Help Contents MK-96HC141-27 2014, 2015 Hitachi, Ltd. All rights reserved. No part of this publication

More information

Tuning Manager. Hitachi Command Suite. Server Administration Guide MK-92HC021-38. FASTFIND LINKS Document Organization. Product Version.

Tuning Manager. Hitachi Command Suite. Server Administration Guide MK-92HC021-38. FASTFIND LINKS Document Organization. Product Version. Hitachi Command Suite Tuning Manager Server Administration Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-92HC021-38 2015 Hitachi, Ltd. All rights reserved. No part

More information

Hitachi Virtual Storage Platform G1000

Hitachi Virtual Storage Platform G1000 Hitachi Virtual Storage Platform G1000 Encryption License Key User Guide FASTFIND LINKS Contents Product Version Getting Help MK-92RD8009-02 2014 Hitachi, Ltd. All rights reserved. No part of this publication

More information

FASTFIND LINKS. Document Organization. Product Version. Getting Help. Contents MK-96RD617-15

FASTFIND LINKS. Document Organization. Product Version. Getting Help. Contents MK-96RD617-15 Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM Hitachi Performance Manager User s Guide Performance Monitor and Server Priority Manager FASTFIND LINKS Document Organization

More information

Hitachi Unified Storage VM Block Module

Hitachi Unified Storage VM Block Module Hitachi Unified Storage VM Block Module System Operations Using Spreadsheets FASTFIND LINKS Contents Product Version Getting Help MK-92HM7015-02 2012-2013 Hitachi Ltd. All rights reserved. No part of this

More information

Hitachi Command Suite

Hitachi Command Suite Hitachi Command Suite Hitachi Command Suite User Guide MK-90HC172-15 2014 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic

More information

Open-Systems Host Attachment Guide

Open-Systems Host Attachment Guide Open-Systems Host Attachment Guide Hitachi Virtual Storage Platform G1000 Hitachi Virtual Storage Platform Hitachi Unified Storage VM Hitachi Universal Storage Platform V/VM FASTFIND LINKS Contents Product

More information

Compute Systems Manager

Compute Systems Manager Hitachi Command Suite Compute Systems Manager User Guide MK-91HC194-10 2014, 2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means,

More information

Hitachi Command Suite. Automation Director. Installation and Configuration Guide MK-92HC204-00

Hitachi Command Suite. Automation Director. Installation and Configuration Guide MK-92HC204-00 Hitachi Command Suite Automation Director Installation and Configuration Guide MK-92HC204-00 2015 Hitachi, Ltd. All rights reserved No part of this publication may be reproduced or transmitted in any form

More information

Hitachi Compute Blade 500 Series NVIDIA GPU Adapter User s Guide

Hitachi Compute Blade 500 Series NVIDIA GPU Adapter User s Guide Hitachi Compute Blade 500 Series NVIDIA GPU Adapter User s Guide FASTFIND LINKS Getting Help Contents MK-91CB500083-01 2010-2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced

More information

Hitachi NAS Blade for TagmaStore Universal Storage Platform and Network Storage Controller NAS Blade Error Codes User s Guide

Hitachi NAS Blade for TagmaStore Universal Storage Platform and Network Storage Controller NAS Blade Error Codes User s Guide Hitachi NAS Blade for TagmaStore Universal Storage Platform and Network Storage Controller NAS Blade Error Codes User s Guide MK-95RD280-03 2006 Hitachi, Ltd., Hitachi Data Systems Corporation, ALL RIGHTS

More information

Hitachi Application Protector Version 1.2 for SAP Release Notes

Hitachi Application Protector Version 1.2 for SAP Release Notes Hitachi Application Protector Version 1.2 for SAP Release Notes Copyright Information... 2 Product Release Information... 4 Introduction... 4 Installation and Configuration Notes... 4 Manifest... 4 Minimum

More information

Hitachi Command Suite. Command Director. User Guide MK-90HCMD001-13

Hitachi Command Suite. Command Director. User Guide MK-90HCMD001-13 Hitachi Command Suite Command Director User Guide MK-90HCMD001-13 2014 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic

More information

Configuration Guide for VMware ESX Server Host Attachment

Configuration Guide for VMware ESX Server Host Attachment Configuration Guide for VMware ESX Server Host Attachment Hitachi Unified Storage VM Hitachi Virtual Storage Platform Hitachi Universal Storage Platform V/VM Hitachi TagmaStore Universal Storage Platform

More information

Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool User's Guide log monitoring functions for VMware vma

Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool User's Guide log monitoring functions for VMware vma Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool User's Guide log monitoring functions for VMware vma FASTFIND LINKS Document Organization Product Version

More information

FASTFIND LINKS. Contents Product Version Getting Help MK-96RD640-05

FASTFIND LINKS. Contents Product Version Getting Help MK-96RD640-05 Configuration Guide for Red Hat Linux Host Attachment Hitachi Unified Storage VM Hitachi Virtual Storage Platform Hitachi Universal Storage Platform V/VM FASTFIND LINKS Contents Product Version Getting

More information

Hitachi Unified Storage File Module Replication and Disaster Recovery Administration Guide Release 12.0

Hitachi Unified Storage File Module Replication and Disaster Recovery Administration Guide Release 12.0 Hitachi Unified Storage File Module Replication and Disaster Recovery Administration Guide Release 12.0 MK-92USF009-03 2011-2014 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced

More information

Hitachi Application Protector User Guide for Microsoft SQL Server

Hitachi Application Protector User Guide for Microsoft SQL Server Hitachi Application Protector User Guide for Microsoft SQL Server FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-91HAP007-06 Copyright 2011-2014 Hitachi, Ltd., Hitachi Data

More information

Configuration Guide for Microsoft Windows Host Attachment

Configuration Guide for Microsoft Windows Host Attachment Configuration Guide for Microsoft Windows Host Attachment Hitachi Unified Storage VM Hitachi Virtual Storage Platform Hitachi Universal Storage Platform V/VM FASTFIND LINKS Contents Product Version Getting

More information

Hitachi Virtual Storage Platform

Hitachi Virtual Storage Platform Hitachi Virtual Storage Platform Hitachi Audit Log User Guide FASTFIND LINKS Contents Product Version Getting Help MK-90RD7007-12 2010-2014 Hitachi, Ltd. All rights reserved. No part of this publication

More information

Hitachi Virtual Storage Platform

Hitachi Virtual Storage Platform Hitachi Virtual Storage Platform User and Reference Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-90RD7042-10 2010-2013 Hitachi Ltd, All rights reserved. No part of

More information

HiCommand Dynamic Link Manager (HDLM) for Windows Systems User s Guide

HiCommand Dynamic Link Manager (HDLM) for Windows Systems User s Guide HiCommand Dynamic Link Manager (HDLM) for Windows Systems User s Guide MK-92DLM129-13 2007 Hitachi Data Systems Corporation, ALL RIGHTS RESERVED Notice: No part of this publication may be reproduced or

More information

Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool OS Setup Guide

Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool OS Setup Guide Hitachi Compute Blade Series Hitachi Compute Rack Series FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-99COM061-07 2012-2015 Hitachi, Ltd. All rights reserved. No part of

More information

Hitachi Storage Replication Adapter Software VMware vcenter Site Recovery Manager Deployment Guide

Hitachi Storage Replication Adapter Software VMware vcenter Site Recovery Manager Deployment Guide Hitachi Storage Replication Adapter Software VMware vcenter Site Recovery Manager Deployment Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-09RM6745-01 Copyright 2009

More information

Hitachi Virtual Storage Platform

Hitachi Virtual Storage Platform Hitachi Virtual Storage Platform Hitachi Storage Navigator User Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-90RD7027-11 2010-2013 Hitachi Ltd, All rights reserved.

More information

Hitachi Content Platform Installing an HCP System

Hitachi Content Platform Installing an HCP System Hitachi Content Platform MK-99ARC026-11 2009 2015 Hitachi Data Systems Corporation. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, electronic

More information

Hitachi Unified Storage VM Block Module

Hitachi Unified Storage VM Block Module Hitachi Unified Storage VM Block Module Hitachi Universal Replicator User Guide FASTFIND LINKS Contents Product Version Getting Help MK-92HM7019-08 2012-2014 Hitachi, Ltd. All rights reserved. No part

More information

Hitachi Data Systems Software

Hitachi Data Systems Software P r o d u c t L i n e C a r d Data Systems Software and Data Management Basic Operating System Dynamic Provisioning Dynamic Tiering Compatible PAV for IBM z/os Compatible HyperPAV for IBM z/os Cross-OS

More information

Hitachi Device Manager Software Getting Started Guide

Hitachi Device Manager Software Getting Started Guide Hitachi Device Manager Software Getting Started Guide FASTFIND LINKS Document Organization Software Version Getting Help Contents MK-98HC149-03 Copyright 2008, 2009 Hitachi Ltd., Hitachi Data Systems Corporation,

More information

Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool User's Guide log monitoring functions for VMware vma

Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool User's Guide log monitoring functions for VMware vma Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool User's Guide log monitoring functions for VMware vma FASTFIND LINKS Document Organization Product Version

More information

Hitachi NAS Platform F1000 Series

Hitachi NAS Platform F1000 Series Hitachi NAS Platform F1000 Series Cluster Troubleshooting Guide Product Version Getting Help Contents MK-92NAS066-07 2012-2015 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced

More information

Replication and Disaster Recovery Administration Guide

Replication and Disaster Recovery Administration Guide Hitachi Unified Storage File Module Replication and Disaster Recovery Administration Guide Release 12.1 MK-92USF009-04 2011-2014 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced

More information

Acer Hitachi AS2040 specifications

Acer Hitachi AS2040 specifications Product overview The Acer Hitachi AS2040 is a reliable and robust storage system designed with the small and mid-sized business in mind. Designed with enterprise-class features and simplified management

More information

Hitachi Storage Command Suite Hitachi Protection Manager Software VSS Backup of Microsoft Exchange Server Getting Started Guide

Hitachi Storage Command Suite Hitachi Protection Manager Software VSS Backup of Microsoft Exchange Server Getting Started Guide Hitachi Storage Command Suite Hitachi Protection Manager Software VSS Backup of Microsoft Exchange Server Getting Started Guide MK-96HC127-05 2008 Hitachi, Ltd., Hitachi Data Systems Corporation, ALL

More information

Acer Hitachi AMS 2100 specifications

Acer Hitachi AMS 2100 specifications Product overview For small and mid-sized businesses, Acer Hitachi Adaptable Modular Storage 2100 is an easy-to-use, scalable, cost-effective storage system for Microsoft Exchange Server, VMware, databases

More information

Hitachi Virtual Storage Platform

Hitachi Virtual Storage Platform Hitachi Virtual Storage Platform Hitachi SNMP Agent User Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-90RD7025-09 2010-2013 Hitachi Ltd. All rights reserved. No part

More information

VERITAS Bare Metal Restore 4.6 for VERITAS NetBackup

VERITAS Bare Metal Restore 4.6 for VERITAS NetBackup VERITAS Bare Metal Restore 4.6 for VERITAS NetBackup System Administrator s Guide for UNIX and Windows N09870C Disclaimer The information contained in this publication is subject to change without notice.

More information

Backup Server DOC-OEMSPP-S/6-BUS-EN-21062011

Backup Server DOC-OEMSPP-S/6-BUS-EN-21062011 Backup Server DOC-OEMSPP-S/6-BUS-EN-21062011 The information contained in this guide is not of a contractual nature and may be subject to change without prior notice. The software described in this guide

More information

Hitachi Unified Storage VM Block Module

Hitachi Unified Storage VM Block Module Hitachi Unified Storage VM Block Module Hardware User Guide FASTFIND LINKS Contents Product Version Getting Help MK-92HM7005-04 2012-2013 Hitachi Ltd. All rights reserved. No part of this publication may

More information

Hitachi Command Suite

Hitachi Command Suite Hitachi Command Suite Audit Log Reference Guide Document Organization Product Version Getting Help Contents MK-92HC213-01 2014 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced

More information

XP24000/XP20000 Performance Monitor User Guide

XP24000/XP20000 Performance Monitor User Guide HP StorageWorks XP24000/XP20000 Performance Monitor User Guide Abstract This user's guide describes and provides instructions for using the Performance Monitor software. Part Number: T5214-96088 Eleventh

More information

Lab Validation Report. By Steven Burns. Month Year

Lab Validation Report. By Steven Burns. Month Year 1 Hyper-V v2 Host Level Backups Using Symantec NetBackup 7.0 and the Hitachi VSS Hardware Provider with the Hitachi Adaptable Modular Storage 2000 Family Lab Validation Report By Steven Burns March 2011

More information

Job Management Partner 1/Performance Management - Remote Monitor for Virtual Machine Description, User's Guide and Reference

Job Management Partner 1/Performance Management - Remote Monitor for Virtual Machine Description, User's Guide and Reference Job Management Partner 1 Version 10 Job Management Partner 1/Performance Management - Remote Monitor for Virtual Machine Description, User's Guide and Reference 3021-3-353(E) Relevant program products

More information

Scheduler Job Scheduling Console

Scheduler Job Scheduling Console Tivoli IBM Tivoli Workload Scheduler Job Scheduling Console Feature Level 1.3 (Revised December 2004) User s Guide SC32-1257-02 Tivoli IBM Tivoli Workload Scheduler Job Scheduling Console Feature Level

More information

Hitachi NAS Platform Deduplication Best Practices Guide

Hitachi NAS Platform Deduplication Best Practices Guide Hitachi NAS Platform Deduplication Best Practices Guide By Francisco Salinas (Global Services Engineering) MK-92HNAS031-00 2011-2013 Hitachi, Ltd. All rights reserved. No part of this publication may be

More information

Tivoli Storage Manager

Tivoli Storage Manager Tivoli Storage Manager for Mail Version 5.3 Data Protection for Microsoft Exchange Server Installation and User s Guide SC32-9058-03 Tivoli Storage Manager for Mail Version 5.3 Data Protection for Microsoft

More information

Using Hitachi ShadowImage and Hitachi TrueCopy software with the IBM DB2 Universal Database Enterprise Server Edition Version 8.1

Using Hitachi ShadowImage and Hitachi TrueCopy software with the IBM DB2 Universal Database Enterprise Server Edition Version 8.1 Enterprise Storage Using Hitachi ShadowImage and Hitachi TrueCopy software with the IBM DB2 Universal Database Enterprise Server Edition Version 8.1 A White Paper September 2003 Hitachi, Ltd. Disk Array

More information

Storage Subsystem Administration Guide

Storage Subsystem Administration Guide Hitachi Unified Storage File Module Storage Subsystem Administration Guide Release 12.1 MK-92USF006-05 Hitachi Data Systems products and services can be ordered only under the terms and conditions of Hitachi

More information

Hitachi NAS Platform Backup Administration Guide Release 12.0

Hitachi NAS Platform Backup Administration Guide Release 12.0 Hitachi NAS Platform Backup Administration Guide Release 12.0 MK-92HNAS007-03 2011-2014 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by

More information

Hitachi TagmaStore Universal Storage Platform and Network Storage Controller. Partner Beyond Technology

Hitachi TagmaStore Universal Storage Platform and Network Storage Controller. Partner Beyond Technology Hitachi TagmaStore Universal Storage Platform and Network Storage Controller Partner Beyond Technology Hitachi TagmaStore Universal Storage Platform and Network Storage Controller Having established a

More information

Hitachi NAS Platform F1000 Series

Hitachi NAS Platform F1000 Series Hitachi NAS Platform F1000 Series Single Node Administrator's Guide Product Version Getting Help Contents MK-92NAS089-05 2013-2015 Hitachi, Ltd. All rights reserved. No part of this publication may be

More information

Basic System. Vyatta System. REFERENCE GUIDE Using the CLI Working with Configuration System Management User Management Logging VYATTA, INC.

Basic System. Vyatta System. REFERENCE GUIDE Using the CLI Working with Configuration System Management User Management Logging VYATTA, INC. VYATTA, INC. Vyatta System Basic System REFERENCE GUIDE Using the CLI Working with Configuration System Management User Management Logging Vyatta Suite 200 1301 Shoreway Road Belmont, CA 94002 vyatta.com

More information

Building Continuous Cloud Infrastructures

Building Continuous Cloud Infrastructures Building Continuous Cloud Infrastructures Deepak Verma, Senior Manager, Data Protection Products & Solutions John Harker, Senior Product Marketing Manager October 8, 2014 WebTech Educational Series Building

More information

FlexArray Virtualization

FlexArray Virtualization Updated for 8.2.1 FlexArray Virtualization Installation Requirements and Reference Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support

More information

High Availability. Vyatta System

High Availability. Vyatta System VYATTA, INC. Vyatta System High Availability REFERENCE GUIDE WAN Load Balancing VRRP Clustering Stateful NAT and Firewall Failover RAID 1 Configuration Synchronization Vyatta Suite 200 1301 Shoreway Road

More information

Protect SQL Server 2012 AlwaysOn Availability Group with Hitachi Application Protector

Protect SQL Server 2012 AlwaysOn Availability Group with Hitachi Application Protector Protect SQL Server 2012 AlwaysOn Availability Group with Hitachi Application Protector Tech Note Nathan Tran The purpose of this tech note is to show how organizations can use Hitachi Applications Protector

More information

Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool User's Guide log monitoring functions

Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool User's Guide log monitoring functions Hitachi Compute Blade Series Hitachi Compute Rack Series Server installation and monitoring tool User's Guide log monitoring functions FASTFIND LINKS Getting Help Contents MK-99COM064-02 2010-2014 Hitachi,

More information

Microsoft SQL Server Always On Technologies

Microsoft SQL Server Always On Technologies Microsoft SQL Server Always On Technologies Hitachi Data Systems Contributes Always On Storage Solutions A Partner Solutions White Paper By Rick Andersen and Simon Pengelly December 2006 Executive Summary

More information

Back-up Server DOC-OEMSPP-S/2014-BUS-EN-10/12/13

Back-up Server DOC-OEMSPP-S/2014-BUS-EN-10/12/13 Back-up Server DOC-OEMSPP-S/2014-BUS-EN-10/12/13 The information contained in this guide is not of a contractual nature and may be subject to change without prior notice. The software described in this

More information

Hitachi Data Systems and Brocade Disaster Recovery Solutions for VMware Environments

Hitachi Data Systems and Brocade Disaster Recovery Solutions for VMware Environments Hitachi Data Systems and Brocade Disaster Recovery Solutions for VMware Environments Technical Brief By Sarah Hamilton, Hitachi Data Systems Marcus Thordal, Brocade July 2009 Executive Summary The rapid

More information

EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution

EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution Release 3.0 User Guide P/N 300-999-671 REV 02 Copyright 2007-2013 EMC Corporation. All rights reserved. Published in the USA.

More information

Storage Systems User Administration

Storage Systems User Administration Hitachi Unified Storage File Module Storage Systems User Administration Release 12.1 MK-92USF011-04 2011-2014 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted

More information

Hitachi Storage Command Suite Hitachi Protection Manager Software for Microsoft SQL Server Getting Started Guide

Hitachi Storage Command Suite Hitachi Protection Manager Software for Microsoft SQL Server Getting Started Guide Hitachi Storage Command Suite Hitachi Protection Manager Software for Microsoft SQL Server Getting Started Guide MK-96HC128-05 2008 Hitachi, Ltd., Hitachi Data Systems Corporation, ALL RIGHTS RESERVED

More information

IBM TSM DISASTER RECOVERY BEST PRACTICES WITH EMC DATA DOMAIN DEDUPLICATION STORAGE

IBM TSM DISASTER RECOVERY BEST PRACTICES WITH EMC DATA DOMAIN DEDUPLICATION STORAGE White Paper IBM TSM DISASTER RECOVERY BEST PRACTICES WITH EMC DATA DOMAIN DEDUPLICATION STORAGE Abstract This white paper focuses on recovery of an IBM Tivoli Storage Manager (TSM) server and explores

More information

Vicom Storage Virtualization Engine. Simple, scalable, cost-effective storage virtualization for the enterprise

Vicom Storage Virtualization Engine. Simple, scalable, cost-effective storage virtualization for the enterprise Vicom Storage Virtualization Engine Simple, scalable, cost-effective storage virtualization for the enterprise Vicom Storage Virtualization Engine (SVE) enables centralized administration of multi-platform,

More information

How To Manage A Cluster Server On A Server Farm On A Microsoft Server Farm (Microsoft) On A Network (Netware) On An Uniden Server (Networking) On Your Server Farm

How To Manage A Cluster Server On A Server Farm On A Microsoft Server Farm (Microsoft) On A Network (Netware) On An Uniden Server (Networking) On Your Server Farm Hitachi Unified Storage File Module Server and Cluster Administration Guide Release 12.0 MK-92USF007-05 2011-2014 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted

More information

IBM Tivoli Storage Manager for Mail Version 7.1.4. Data Protection for Microsoft Exchange Server Installation and User's Guide IBM

IBM Tivoli Storage Manager for Mail Version 7.1.4. Data Protection for Microsoft Exchange Server Installation and User's Guide IBM IBM Tivoli Storage Manager for Mail Version 7.1.4 Data Protection for Microsoft Exchange Server Installation and User's Guide IBM IBM Tivoli Storage Manager for Mail Version 7.1.4 Data Protection for

More information

Server and Cluster Administration Guide

Server and Cluster Administration Guide Hitachi NAS Platform Server and Cluster Administration Guide Release 12.2 MK-92HNAS010-06 2011-2014 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any

More information

HP StorageWorks Automated Storage Manager User Guide

HP StorageWorks Automated Storage Manager User Guide HP StorageWorks Automated Storage Manager User Guide Part Number: 5697 0422 First edition: June 2010 Legal and notice information Copyright 2010, 2010 Hewlett-Packard Development Company, L.P. Confidential

More information

Server Installation Guide ZENworks Patch Management 6.4 SP2

Server Installation Guide ZENworks Patch Management 6.4 SP2 Server Installation Guide ZENworks Patch Management 6.4 SP2 02_016N 6.4SP2 Server Installation Guide - 2 - Notices Version Information ZENworks Patch Management Server Installation Guide - ZENworks Patch

More information

File Services Administration Guide

File Services Administration Guide Hitachi NAS Platform File Services Administration Guide Release 12.2 MK-92HNAS006-05 2011-2014 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form

More information

Deploying SAP on Microsoft SQL Server 2008 Environments Using the Hitachi Virtual Storage Platform

Deploying SAP on Microsoft SQL Server 2008 Environments Using the Hitachi Virtual Storage Platform 1 Deploying SAP on Microsoft SQL Server 2008 Environments Using the Hitachi Virtual Storage Platform Implementation Guide By Sean Siegmund June 2011 Feedback Hitachi Data Systems welcomes your feedback.

More information

Data Replication User s Manual (Installation and Operation Guide for Windows)

Data Replication User s Manual (Installation and Operation Guide for Windows) NEC Storage Manager Data Replication User s Manual (Installation and Operation Guide for Windows) IS016-5E NEC Corporation 2001-2004 No part of the contents of this book may be reproduced or transmitted

More information

Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM User and Reference Guide

Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM User and Reference Guide Hitachi Universal Storage Platform V Hitachi Universal Storage Platform VM User and Reference Guide FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-96RD635-12 Copyright 2009

More information

Best Practices for Oracle Automatic Storage Management (ASM) on Hitachi Dynamic Provisioning(HDP)

Best Practices for Oracle Automatic Storage Management (ASM) on Hitachi Dynamic Provisioning(HDP) Best Practices for Oracle Automatic Storage Management (ASM) on Hitachi Dynamic Provisioning(HDP) Rev. 0 March 2008 1 Introduction Until now, when storage was introduced, generally future capacity requirements

More information

Silect Software s MP Author

Silect Software s MP Author Silect MP Author for Microsoft System Center Operations Manager Silect Software s MP Author User Guide September 2, 2015 Disclaimer The information in this document is furnished for informational use only,

More information

StarWind Virtual SAN Installation and Configuration of Hyper-Converged 2 Nodes with Hyper-V Cluster

StarWind Virtual SAN Installation and Configuration of Hyper-Converged 2 Nodes with Hyper-V Cluster #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Installation and Configuration of Hyper-Converged 2 Nodes with MARCH 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the

More information

TIBCO Administrator User s Guide. Software Release 5.7.1 March 2012

TIBCO Administrator User s Guide. Software Release 5.7.1 March 2012 TIBCO Administrator User s Guide Software Release 5.7.1 March 2012 Important Information SOME TIBCO SOFTWARE EMBEDS OR BUNDLES OTHER TIBCO SOFTWARE. USE OF SUCH EMBEDDED OR BUNDLED TIBCO SOFTWARE IS SOLELY

More information

Database FAQs - SQL Server

Database FAQs - SQL Server Database FAQs - SQL Server Kony Platform Release 5.0 Copyright 2013 by Kony, Inc. All rights reserved. August, 2013 This document contains information proprietary to Kony, Inc., is bound by the Kony license

More information

High Availability Guide for Distributed Systems

High Availability Guide for Distributed Systems Tivoli IBM Tivoli Monitoring Version 6.2.2 Fix Pack 2 (Revised May 2010) High Availability Guide for Distributed Systems SC23-9768-01 Tivoli IBM Tivoli Monitoring Version 6.2.2 Fix Pack 2 (Revised May

More information

HP 3PAR Online Import for HDS Storage 1.3.0 Data Migration Guide

HP 3PAR Online Import for HDS Storage 1.3.0 Data Migration Guide HP 3PAR Online Import for HDS Storage 1.3.0 Data Migration Guide Abstract This guide provides information on using HP 3PAR Online Import for HDS Storage software to migrate data from an HDS Storage system

More information

BrightStor ARCserve Backup for Windows

BrightStor ARCserve Backup for Windows BrightStor ARCserve Backup for Windows Enterprise Option for Microsoft SQL Using HP-XP Snap-Shot Guide r11.5 D01190-2E This documentation and related computer software program (hereinafter referred to

More information

HP StorageWorks Auto LUN XP user guide. for the XP12000/XP10000

HP StorageWorks Auto LUN XP user guide. for the XP12000/XP10000 HP StorageWorks Auto LUN XP user guide for the XP12000/XP10000 Part number: T1715-96006 Sixth edition: September 2007 Legal and notice information Copyright 2005, 2007 Hewlett-Packard Development Company,

More information

EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution

EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution EMC NetWorker Module for Microsoft for Windows Bare Metal Recovery Solution Version 9.0 User Guide 302-001-755 REV 01 Copyright 2007-2015 EMC Corporation. All rights reserved. Published in USA. Published

More information

Business Enterprise Server Help Desk Integration Guide. Version 3.5

Business Enterprise Server Help Desk Integration Guide. Version 3.5 Business Enterprise Server Help Desk Integration Guide Version 3.5 June 30, 2010 Copyright Copyright 2003 2010 Interlink Software Services, Ltd., as an unpublished work. All rights reserved. Interlink

More information

Hitachi Virtual Storage Platform G1000

Hitachi Virtual Storage Platform G1000 Hitachi Virtual Storage Platform G1000 Product Overview MK-92RD8051-01 2014 Hitachi, Ltd. All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means,

More information

HP ProLiant PRO Management Pack (v 2.0) for Microsoft System Center User Guide

HP ProLiant PRO Management Pack (v 2.0) for Microsoft System Center User Guide HP ProLiant PRO Management Pack (v 2.0) for Microsoft System Center User Guide Abstract This guide provides information on using the HP ProLiant PRO Management Pack for Microsoft System Center version

More information