CLAMP MULTIMETER F205
|
|
|
- Janice Roberts
- 10 years ago
- Views:
Transcription
1 CLAMP MULTIMETER F205 ENGLISH User s manual
2 Clamp Multimeter F205 English CONTENTS 1 PRESENTATION THE SWITCH THE KEYS OF THE KEYPAD THE DISPLAY UNIT The symbols of the display unit Measurement capacity exceeded (O.L) THE TERMINALS THE KEYS KEY KEY (SECOND FUNCTION) KEY KEY In the normal mode The MAX/MIN/PEAK mode + activation of the HOLD mode Access to the True-INRUSH mode ( set to ) KEY The Hz function in the normal model The Hz function + activation of the HOLD mode KEY USE COMMISSIONING STARTING UP THE CLAMP MULTIMETER SWITCHING THE CLAMP MULTIMETER CONFIGURATION Programming of the maximum resistance allowed for a continuity De-activation of automatic switching off (Auto Power OFF) Programming of the current threshold for the True INRUSH measurement Default configuration VOLTAGE MEASUREMENT (V) CONTINUITY TEST Automatic compensation of the resistance of the leads RESISTANCE MEASUREMENT DIODE TEST CURRENT MEASUREMENT (A) AC measurement DC or AC+DC measurement
3 English Clamp Multimeter F STARTING CURRENT OR OVERCURRENT (TRUE INRUSH) MEASUREMENT POWER MEASUREMENTS W, VA, VAR AND PF Measurement of single-phase power Balanced three-phase power measurement DIRECTION OF ROTATION OF THE PHASES OR ORDER OF THE PHASES MODE FREQUENCY MEASUREMENT (HZ) Frequency measurement in voltage Frequency measurement in current Measurement of frequency in power MEASUREMENT OF THE LEVEL OF HARMONICS (THD) AND OF THE FREQUENCY OF THE FUNDAMENTAL (NETWORK) Measurement of the THD and of the frequency of the fundamental in voltage Measurement of the THD and of the frequency of the fundamental in current CHARACTERISTICS REFERENCE CONDITIONS CHARACTERISTICS UNDER THE REFERENCE CONDITIONS DC voltage measurement AC voltage measurement AC+DC voltage measurement DC current measurement AC current measurement AC+DC intensity measurement True-Inrush measurement Continuity measurement Resistance measurement Diode test Active DC power measurements Active AC power measurements Active AC+DC power measurements Measurement of apparent AC power Measurement of apparent AC+DC power Measurement of reactive AC power Measurement of reactive AC+DC power Calculation of the power factor Frequency measurements Characteristics in THDr Characteristics in THDf Indication of order of the phases ENVIRONMENTAL CONDITIONS CHARACTERISTICS OF CONSTRUCTION
4 Clamp Multimeter F205 English 4.5 POWER SUPPLY COMPLIANCE WITH INTERNATIONAL STANDARDS VARIATIONS IN THE DOMAIN OF USE MAINTENANCE CLEANING REPLACEMENT OF THE BATTERY METROLOGICAL CHECK REPAIR WARRANTY DELIVERY CONDITION
5 English Clamp Multimeter F205 You have just acquired an F205 clamp multimeter and we thank you. For best results from your device : read this user manual attentively, observe the precautions for its use. Meanings of the symbols used on the device Danger. The operator agrees to refer to this data sheet whenever this danger symbol is encountered. Application or withdrawal authorized on uninsulated or bare conductors at dangerous voltages. 9 V battery. The CE marking indicates compliance with European directives. Double insulation or reinforced insulation. Selective sorting of wastes for the recycling of electrical and electronic equipment within the European Union. In conformity with directive DEEE 2002/96/EC: this equipment must not be treated as household waste. AC Alternating current. AC and DC Alternating and direct current. Earth. Risk of electric shock. 5
6 Clamp Multimeter F205 English PRECAUTIONS FOR USE This device complies with safety standards IEC and for voltages of 1000V in category III or 600V in category IV at an altitude OF less than 2000m, indoors, with a degree of pollution not exceeding 2. These safety instructions are intended to ensure the safety of persons and proper operation of the device. If the tester is used other than as specified in this data sheet, the protection provided by the device may be impaired. The operator and/or the responsible authority must carefully read and clearly understand the various precautions to be taken in use. If you use this instrument other than as specified, the protection it provides may be compromised, thereby endangering you. Do not use the instrument in an explosive atmosphere or in the presence of flammable gases or fumes. Do not use the instrument on networks of which the voltage or category exceeds those mentioned. Do not exceed the rated maximum voltages and currents between terminals or with respect to earth. Do not use the instrument if it appears to be damaged, incomplete, or not properly closed. Before each use, check the condition of the insulation on the leads, housing, and accessories. Any element of which the insulation is deteriorated (even partially) must be set aside for repair or scrapped. Use leads and accessories rated for voltages and categories at least equal to those of the instrument. If not, an accessory of a lower category lowers the category of the combined Clamp + accessory to that of the accessory. Observe the environmental conditions of use. Do not modify the instrument and do not replace components with "equivalents". Repairs and adjustments must be done by approved qualified personnel. Replace the battery as soon as the symbol appears on the display unit. Disconnect all cords before opening the battery compartment cover. Use personal protective equipment when conditions require. Keep your hands away from the unused terminals of the instrument. 6
7 English Clamp Multimeter F205 When handling the test probes, crocodile clips, and clamp ammeters, keep your fingers behind the physical guard. As a safety measure, and to avoid repeated overloads on the inputs of the device, we recommend performing configuration operations only when the device is disconnected from all dangerous voltages. MEASUREMENT CATEGORIES Definitions of the measurement categories : CAT II: Circuits directly connected to the low-voltage installation. Example: power supply to household electrical appliances and portable tools. CAT III: Power supply circuits in the installation of the building. Example: distribution panel, circuit-breakers, fixed industrial machines or devices. CAT IV: Circuits supplying the low-voltage installation of the building. Example: power lines, meters, and protection devices. 7
8 Clamp Multimeter F205 English 1 PRESENTATION The F205 is a professional electrical measuring instrument that combines the following functions: Current measurement; Measurement of inrush current / overcurrent (True-Inrush); Voltage measurement; Frequency measurement; Measurement of level of harmonics (THD) Continuity test with buzzer; Resistance measurement; Diode test; Power measurements (W, VA, var and PF); Indication of the order of the phases Item Designation See 1 Jaws with centring marks (see connection principles) 3.5 to Physical guard - 3 Switch Function keys 2 5 Display unit Terminals Trigger - 6 Figure 1 : the F205 clamp multimeter 8
9 English Clamp Multimeter F THE SWITCH The switch has six positions. To access the,,,,, functions, set the switch to the desired function. Each setting is confirmed by an audible signal. The functions are described in the table below Figure 2 : the switch Item Function See 1 OFF mode Switches the clamp multimeter off AC, DC, AC+DC voltage measurement (V) Continuity test Resistance measurement Ω Diode test 4 AC, DC, AC+DC current measurement (A) Power measurements (W, var, VA) and calculation of the power factor (PF) AC, DC, AC+DC Indicator of the order of the phases
10 Clamp Multimeter F205 English 1.2 THE KEYS OF THE KEYPAD Here are the six keys of the keypad : Figure 3 : the keys of the keypad Item Function See 1 Storage of values, disabling of display Zero correction A DC /A AC+DC /W DC /W AC+DC Compensation of the resistance of the leads in the continuity and ohmmeter function 2 Selection of the type of measurement (AC, DC, AC+DC) Selection of single-phase or three-phase measurement 3 Activation or de-activation of the backlighting of the display unit 4 Activation or de-activation of the MAX/MIN/PEAK mode Activation or de-activation of the INRUSH mode in A 5 Measurements of frequency (Hz), of the level of harmonics (THD) Display of the powers W, VA, var and PF 6 Activation of the ΔREL mode Display of relative and differential values
11 English Clamp Multimeter F THE DISPLAY UNIT Here is the display unit of the clamp multimeter: Figure 4 : the display unit 5 Item Function See 1 Display of the modes selected (keys) 2 2 Display of the measurement value and unit 3.5 to Display of the MAX/MIN/PEAK modes Type of measurement (AC or DC) Total three-phase power measurements Display of the selected modes (switch) Spent battery indication The symbols of the display unit Symbol AC DC AC+DC REL Ref Designation Alternating current or voltage Direct current or voltage Alternating and direct current or voltage Relative value, with respect to a reference Reference value 11
12 Clamp Multimeter F205 English Storage of the values and hold of the display Max Min Peak+ Peak- Maximum RMS value Minimum RMS value Maximum peak value Minimum peak value Balanced total three-phase power measurement V Hz W A Volt Hertz Watt Ampere % Percentage Ω m k var VA PF THD f THD r Ohm Milli- prefix Kilo- prefix Reactive power Apparent power Power factor Total harmonic distortion with respect to the fundamental Total harmonic distortion with respect to the true RMS value of the signal. Indicator of order to the phases Compensation of the resistance of the leads Continuity test Diode test Permanent display (automatic switching off de-activated) Spent battery indicator The display of rdy, for ready, indicates that the device is ready ( Indicator of order of the phases function). 12
13 English Clamp Multimeter F Measurement capacity exceeded (O.L) The O.L (Over Load) symbol is displayed when the display capacity is exceeded. 1.4 THE TERMINALS The terminals are used as follows: Item Function 1 Cold terminal (COM) 2 Hot terminal (+) 1 2 Figure 5 : the terminals 2 THE KEYS The keys of the keypad respond differently to short, long, and sustained presses. The, and keys provide new functions and allow the detection and acquisition of parameters complementary to the usual elementary measurements. - Each of these keys can be used independently of the others or in perfect complementarity with them: this makes navigation simple and intuitive for looking up all measurement results. - It is possible, for example, to look up in turn the MAX, MIN, etc. values of the RMS voltage alone, or else look up in turn all of the MAX (or MIN, or PEAK) values of all power results (W, VA, var, etc.). In this section, the icon represents the possible positions of the switch for which the key concerned has some action. 2.1 KEY This key is used to: store and look up the last values acquired specific to each function (V, A, Ω, T ) according to the specific modes previously activated (MAX/MIN); the present display is then maintained while the detection and acquisition of new values continues; 13
14 Clamp Multimeter F205 English perform automatic compensation of the resistance of the leads (see also 3.6.1) ; perform an automatic zero correction in A DC / AC+DC et W DC / AC+DC (see also 3.9.2) Remark : the key is invalid for the Indication of order of phases function. Successive presses on serve short Long (>2 sec) Sustained A DC A AC+DC W DC W AC+DC 1. to store the results of the present measurements 2. to hold the display of the last value displayed 3. to return to normal display mode (the value of each new measurement is displayed) to perform automatic compensation of the zero (see 3.9.2) Remark : this mode operates if the MAX/MIN/PEAK or HOLD modes (short press) are first desactivated to perform automatic compensation of the resistance of the leads (see 3.6.1) See also and for the action key with the action of the key and with the action of the key. 2.2 KEY (SECOND FUNCTION) This key is used to select the type of measurement (AC, DC, AC+DC) and the second functions marked in yellow next to the relevant positions of the switch. It can also be used, in the configuration mode, to modify the default value (see 3.4) Remark: the key is invalid in the MAX/MIN/PEAK, HOLD and ΔREL modes. 14
15 English Clamp Multimeter F205 Successive presses on short serve -to select AC, DC or AC+DC. Depending on your choice, the screen displays AC, DC or AC+DC Long (>2 sec) -to cycle through the and diode test to the continuity test modes and to return - to reset the measurement process for the indicator of order of rotation of the phases function. - to display the total three-phase power of a balanced system ( is displayed). - by pressing again, to return to display of the single-phase power ( is off) 2.3 KEY This key is used to backlight the display unit. Successive presses on serve -to activate or de-activate the backlighting of the screen Remark: the backlighting is switched off automatically at the end of 2 minutes. 2.4 KEY In the normal mode This key activates detection of the MAX, MIN, PEAK+ and PEAK- values of the measurements made. Max and Min are the extreme mean values in DC and the extreme RMS values in AC. Peak+ is the maximum instantaneous peak and Peak- the minimum instantaneous peak. Remark : in this mode, the "automatic switching off" function of the device is automatically de-activated. The symbol is displayed on the screen. 15
16 Clamp Multimeter F205 English Successive presses on short long (> 2 sec) serve -to activate detection of the MAX/MIN/PEAK values -to display the MAX, MIN, PEAK+ or PEAK- value successively -to return to display of the present measurement without exiting from the mode (the values already detected are not erased) Remark: the MAX, MIN, PEAK+, PEAK- symbols are both displayed, but only the symbol of the quantity selected blinks. Example: If MIN has been selected, MIN blinks and MAX, PEAK+, PEAKare lit steadily. -to activate detection of the MAX/MIN values -to display the MAX or MIN value successively -to return to display of the present measurement without exiting from the mode (the values already detected are not erased) to exit from the MAX/MIN/PEAK mode. The values previously recorded are then erased. Remark: if the HOLD function is activated, it is not possible to exit from the MAX/MIN/PEAK mode. The HOLD function must first be de-activated. Remark : ΔREL function can be used with the functions of the MAX/MIN/PEAK mode The MAX/MIN/PEAK mode + activation of the HOLD mode Successive presses on serve short to display successively the MAX/MIN/PEAK values detected before the key was pressed. Note : the HOLD function does not interrupt the acquisition of new MAX, MIN, PEAK values Access to the True-INRUSH mode ( set to ) This key allows measurement of the True-Inrush current (starting current, or overcurrent in steady-state operation) for AC or DC current only (not operational in AC+DC). 16
17 English Clamp Multimeter F205 Successive presses on long (>2 sec) serves to enter the True-INRUSH mode -"Inrh" is displayed for 3s (the backlighting blinks) -the triggering threshold is displayed for 5s (the backlighting is steady); -"------" is displayed and the "A" symbol flashes -after detection and acquisition, the inrush current measurement is displayed, after the calculations stage "------" (backlighting off) Remark: the A symbol flashes to indicate "surveillance" of the signal. to exit from the True-INRUSH mode (return to simple current measurement). short (<2 sec) Note: a short press is functional only if an True-Inrush value has been detected. -to display the PEAK+ value of the current -to display the PEAK- value of the current -to display the RMS true-inrush current Remark: the A symbol is displayed steadily during this sequence. 2.5 KEY This key is used to display the frequency measurements of a signal, of the power, and of the level of harmonics. Remark : this button is not functional in DC. 17
18 Clamp Multimeter F205 English The Hz function in the normal model Successive presses on short long then short serves to display: -the frequency of the signal measured -the present voltage (V) or current (A) measurement to display: -the apparent power (VA) - the reactive power (var) - the power factor (PF) - the frequency of the signal - the active power (W) - to enter or exit from the level of harmonics (THD) calculation and display mode - to select THD f, THD r or the frequency of the fundamental The Hz function + activation of the HOLD mode Successive presses on short -to store the frequency serves -to display successively the stored frequency, then the voltage or the current - to display in turn the stored values of THD f, then of THD r, then of the frequency of the fundamental 2.6 KEY This key is used to display and store the reference value or to display the diferential and relative value, in the unit of magnitude measured or in %. Remark : in phasis rotation mode, the key is not operating. Successive presses on serve 18
19 English Clamp Multimeter F205 short - to enter the ΔREL mode, to store then display the reference value. The ΔRef symbol is displayed. - to display the diferential value: - (current value reference ( ) The ΔREL symbol is displayed. - to display the relative value in % current value reference ( reference ( The ΔREL and % symbols are displayed. - to display the reference. The ΔRef symbol is displayed - to display the current value. The ΔRef symbol blinks. long (>2 sec) to exit from the ΔREL mode Remark : the Relative mode ΔREL function can be used with the functions of the MAX/MIN/PEAK mode. 3 USE 3.1 COMMISSIONING Insert the battery supplied with the device as follows: 1. Using a screwdriver, unscrew the screw of the battery compartment cover (item 1) on the back of the housing and open it. 2. Place the battery in the compartment (item 2), taking care to get the polarities right. 3. Close the battery compartment cover and screw it to the housing. 19
20 Clamp Multimeter F205 English 2 1 Figure 6 : the battery compartment cover 3.2 STARTING UP THE CLAMP MULTIMETER The switch is set to OFF. Turn the switch to the function of your choice. The whole display lights (all symbols) for a few seconds (see 1.3), then the screen of the function chosen is displayed. The clamp multimeter is then ready to make measurements. 3.3 SWITCHING THE CLAMP MULTIMETER The clamp multimeter can be switched off either manually, by setting the switch to OFF, or automatically, after ten minutes with no action on the switch and/or the keys. Thirty (30) seconds before the device is switched off, an audible signal sounds intermittently. To re-activate the device, press any key or turn the switch. 3.4 CONFIGURATION As a safety measure, and to avoid repeated overloads on the inputs of the device, we recommend performing configuration operations only when the device is disconnected from all dangerous voltages. 20
21 English Clamp Multimeter F Programming of the maximum resistance allowed for a continuity To program the maximum resistance allowed for a continuity 1. From the OFF position, hold the key down while turning the switch to, until the "full screen" display ends and a beep is emitted, to enter the configuration mode. The display unit indicates the value below which the buzzer is activated and the symbol is displayed. The value stored by default is 40Ω. The possible values lie between 1Ω and 599Ω. 2. To change the threshold, press the key. The right-hand digit flashes: each press on the key increments it. To shift to the next digit, apply a long press (>2s) to the key. To exit from the programming mode, turn the switch to another setting. The detection threshold chosen is stored (emission of a double beep) De-activation of automatic switching off (Auto Power OFF) To de-activate automatic switching off: In the OFF position, hold the key down while turning the switch to, until the "full screen" display ends and a beep is emitted, to enter the configuration mode. The symbol is displayed. When the key is released, the device is in the voltmeter function in the normal mode. The return to Auto Power OFF takes place when the clamp is switched back on Programming of the current threshold for the True INRUSH measurement To program the triggering current threshold of the True INRUSH measurement: 1. in the OFF position, hold the key down while turning the switch to, until the "full screen" display ends and a beep is emitted, to enter the configuration mode. The display unit indicates the percentage overshoot to apply to the measured current to determine the measurement triggering threshold. The value stored by default is 10%, representing 110% of the established current measured. The possible values are 5%, 10%, 20%, 50%, 70%, 100%, 150%, and 200%. 21
22 Clamp Multimeter F205 English 2. To change the threshold, press the key. The value flashes: each press on the key displays the next value. To record the chosen threshold, apply a long press (>2s) on the key. A confirmation beep is emitted. To exit from the programming mode, turn the switch to another setting. The chosen threshold is stored (emission of a double beep). Note: The starting current measurement triggering threshold is fixed at 1% of the least sensitive range. This threshold is not adjustable Default configuration To reset the clamp to its default parameters (factory configuration): In the OFF position, hold the key down while turning the switch to, until the "full screen" display ends and a beep is emitted, to enter the configuration mode. The "rst" symbol is displayed. After 2 s, the clamp emits a double beep, then all of the symbols of the screen are displayed until the key is released. The default parameters are then restored: Continuity detection threshold =40Ω True Inrush triggering threshold =10% 3.5 VOLTAGE MEASUREMENT (V) To measure a voltage, proceed as follows : 1. Set the switch to ; 2. Connect the black lead to the COM terminal and the red lead to "+". 3. Place the test probes or the crocodile clips on the terminals of the circuit to be measured. The device selects AC or DC automatically according to which measured value is larger. The AC or DC symbol lights in blinking mode. To select AC, DC or AC+DC manually, press the yellow key to reach the desired choice. The symbol corresponding to the choice made then lights in fixed mode. 22
23 English Clamp Multimeter F205 The measured value is displayed on the screen. 3.6 CONTINUITY TEST Warning : Before performing the test, make sure that the circuit is off and any capacitors have been discharged. 1. Set the switch to ; the symbol is displayed ; 2. Connect the black lead to the COM terminal and the red lead to «+». 3. Place the test probes or the crocodile clips on the terminals of the circuit or component to be tested. An audible signal is emitted if there is continuity, and the measured value is displayed on the screen. 23
24 Clamp Multimeter F205 English Automatic compensation of the resistance of the leads Warning : before the compensation is executed, the MAX/MIN and HOLD modes must be de-activated. To perform automatic compensation of the resistance of the leads, proceed as follows: 1. Short-circuit the leads connected to the device. 2. Hold the key down until the display unit indicates the lowest value. The device measures the resistance of the leads. 3. Release the key. The correction and the symbole are displayed. The value displayed is stored. Remark : the correction value is stored only if it is 2. Above 2, the value displayed blinks and is not stored. 3.7 RESISTANCE MEASUREMENT Warning : Before making a resistance measurement, make sure that the circuit is cold and any capacitors have been discharged. 1. Set the switch to and press the key. The symbol is displayed; 2. Connect the black lead to the COM terminal and the red lead to «+»; 3. Place the test probes or the crocodile clips on the terminals of the circuit or component to be measured ; The measured value is displayed on the screen Remark : to measure low resistance values, first carry out the compensation of the resistance of the leads (see 3.6.1). 24
25 English Clamp Multimeter F DIODE TEST Warning: Before performing the diode test, make sure that the circuit is cold and any capacitors have been discharged. 1. Set the switch to and press the key twice. The symbol is displayed. 2. Connect the black lead to the COM terminal and the red lead to «+». 3. Place the test probes or the crocodile clips on the terminals of the component to be tested. The measured value is displayed on the screen. 3.9 CURRENT MEASUREMENT (A) The jaws are opened by pressing the trigger on the body of the device. The arrow on the jaws of the clamp (see the diagram below) must point in the presumed direction of flow of the current, from the generator to the load. Make sure that the jaws have closed correctly. Remark: the measurement results are optimal when the conductor is centred in the jaws (aligned with the centring marks). The device automatically selects AC or DC according to which measured value is larger. The AC or DC symbol blinks AC measurement For an AC current measurement, proceed as follows: 1. Set the switch to and select AC by pressing the key. The AC symbol is displayed. 2. Encircle only the conductor concerned with the clamp ; 25
26 Clamp Multimeter F205 English The measured value is displayed on the screen DC or AC+DC measurement To measure the DC or AC+DC current, if the display unit does not indicate "0", first correct the DC zero as follows: Step 1 : to correct the DC zero Important : The clamp must not be closed on the conductor during the DC zero correction. Hold the clamp in the same position during the whole procedure so that the correction value will be exact. Press the key until the device emits a double beep and displays a value near "0". The correction value is stored until the clamp is powered down. Remark : the correction is effected only if the value displayed is < ± 6 A, otherwise the value displayed blinks and is not stored. The clamp must be recalibrated (see 5.3) Step 2 : to make a measurement 1. The switch is set to. Select DC or AC+DC by pressing the yellow key until the desired choice is reached. 2. Apply the clamp to only the conductor concerned. 26
27 English Clamp Multimeter F205 The measurement is displayed on screen STARTING CURRENT OR OVERCURRENT (TRUE INRUSH) MEASUREMENT Remark : the measurement can be made only in AC or DC mode (AC+DC mode disabled) To measure a starting current or overcurrent, proceed as follows: 1. Set the switch to, correct the DC zero ( 3.9.2), then apply the clamp around the single conductor concerned. 2. Effect a long press on the key. The InRh symbol is displayed, then the triggering threshold. The clamp then awaits detection of the True- Inrush current. "------" is displayed and the "A" symbol flashes. 3. After detection and acquisition for 100 ms, the RMS value of the True-Inrush current is displayed, along with the PEAK+/PEAK- values subsequently. 4. A long press on the key or a change of function leads to exiting from the True-Inrush mode. Remark : the triggering threshold in A is 6A if the initial current is zero (starting of installation); it is that set in the configuration (see 3.4.3) for an established current (overload in a installation) POWER MEASUREMENTS W, VA, VAR AND PF This measurement is possible en single-phase or in balanced three-phase. Reminder : in DC or AC+DC power measurement, first correct the DC zero in current (see 3.9.2, step 1) For the power factor (PF) and the powers VA and var, the measurement is possible only in AC or AC+DC. 27
28 Clamp Multimeter F205 English Measurement of single-phase power 1. Set the switch to and select VA, var, or PF by pressing the key until the desired choice is reached; 2. The device automatically displays AC+DC. To select AC, DC, or AC+DC, press the key until the desired choice is reached. 3. Connect the black lead to the COM terminal and the red lead to "+"; 4. Place the test probes or the crocodile clips of the black lead on the neutral (N), then those of the red lead on the L phase. 5. Clamp only the corresponding conductor, respecting the direction; The measurement is displayed on screen Balanced three-phase power measurement 1. Set the switch to and select VA, var, or PF by pressing the key until the desired choice is reached 2. Press the yellow key until the symbol is displayed. 3. The device automatically displays AC+DC. To select AC, DC, or AC+DC, press the yellow key until the desired choice is reached. 4. Connect the black lead to the COM terminal and the red lead to "+"; 5. Connect the leads and the clamp to the circuit as follows: If the red lead is connected and the black lead is connected then the clamp is on the conductor To the L1 phase to the L2 phase of the L3 phase To the L2 phase to the L3 phase of the L1 phase To the L3 phase to the L1 phase of the L2 phase Reminder : the arrow on the jaws of the clamp (see the diagram below) must point in the presumed direction of flow of the current from the source (producer) to the load (consumer) 28
29 English Clamp Multimeter F205 The measurement is displayed on screen. Remark : You can also measure the three-phase power on a balanced 4-wire network by proceeding in the same way, or by proceeding as for the measurement on a single-phase network, then multiplying the value found by three DIRECTION OF ROTATION OF THE PHASES OR ORDER OF THE PHASES MODE This mode is used to determine the order of the phases of a three-phase network by the "2-wire" method. To determine the order of the phases, proceed as follows: Step 1: determination of a "reference" period: 1. Set the switch to. The rdy symbol is displayed; the device is ready for the first phase order determination measurement; 2. Connect the black lead with crocodile clip to the COM terminal and the red lead with test probe to "+"; 3. Connect the crocodile clip to the presumed L1 phase and apply the red test probe to the presumed L2 phase; 4. Press the yellow key. The ref symbol blinks on the screen. The instrument is ready to determine the reference period. When the reference period has been determined, an audible signal sounds and the ref and symbols are displayed. Remark : if the reference period has not been determined, the device emits a beep and displays the "Err Hz" or "ErrV" message. The symbol flashes, then the "rdy" message is displayed on the screen. Repeat the procedure from 4. 29
30 Clamp Multimeter F205 English Step 2: determination of a "measurement" period: Within the next 10 seconds, apply the test probe to the presumed L3 phase. The "MEAS" indication then blinks on the display unit as soon as the L2 phase is disconnected; the device is in the calculation phase. Remark: if the measurement period has not been determined, the device emits a beep and displays the "Err Hz" or "ErrV" message, then "rdy". Repeat the procedure from 4. Result: when the order of the phases has been determined, the device emits a beep and the indication of order of the phases is displayed on the screen, as follows: when the direction of rotation is direct. The "0" symbol blinks and turns clockwise; when the direction of rotation is reversed. The "0" symbol blinks and turns anticlockwise. Remark: if the order of the phases has not been determined, the device emits a beep and displays the "Err" message. Repeat the procedure from FREQUENCY MEASUREMENT (HZ) The frequency measurement is available in V, W and A for AC and AC+DC quantities. The measurement is based on a count of the passages of the signal through zero (positive-going edges) Frequency measurement in voltage To measure the frequency in voltage, proceed as follows: 1. Set the switch to and press the key. The Hz symbol is displayed. 2. Select AC or AC+DC by pressing the yellow key until the desired choice is reached. 3. Connect the black lead to the COM terminal and the red lead to Place the test probes or the crocodile clips on the terminals of the circuit to be measured. 30
31 English Clamp Multimeter F205 The measured value is displayed on the screen Frequency measurement in current 1. Set the switch to and press the key. The Hz symbol is displayed. 2. Select AC or AC+DC by pressing the yellow key until the desired choice is reached. 3. Encircle only the conductor concerned with the clamp. The measured value is displayed on the screen Measurement of frequency in power In the single-phase AC or AC+DC Power (W) setting, it is possible to display the frequency of the voltage of the signal on the terminals. In the balanced three-phase AC or AC+DC Power (W) setting, it is possible to display the frequency of the phase-to-phase voltage of the signal on the terminals. 31
32 Clamp Multimeter F205 English 3.14 MEASUREMENT OF THE LEVEL OF HARMONICS (THD) AND OF THE FREQUENCY OF THE FUNDAMENTAL (NETWORK) The device measures the total harmonic distortion with respect to the fundamental (THD f ) and the total harmonic distortion with respect to the true RMS value of the signal (THD r ) in voltage and in current. Similarly, it determines the frequency of the fundamental by digital filtering and FFT, for network frequencies of 50, 60, 400, and 800Hz Measurement of the THD and of the frequency of the fundamental in voltage 1. Set the switch to and press and hold (>2s) the key. The THD f symbol is displayed. To select THD r, press the key again. The THD r symbol is displayed. To select the frequency of the fundamental, press the key again. The Hz symbol is displayed. 2. Connect the black lead to the COM terminal and the red lead to «+»; 3. Place the test probes or the crocodile clips on the terminals of the circuit to be measured; The measurement is displayed on screen Measurement of the THD and of the frequency of the fundamental in current 1. Set the switch to and press and hold (>2s) the key. The THD f symbol is displayed. To select THD r, press again. The THD r symbol is displayed. To select the frequency of the fundamental, press the key again The Hz symbol is displayed. 2. Apply the clamp to only the conductor concerned. 32
33 English Clamp Multimeter F205 The measurement is displayed on screen. 4 CHARACTERISTICS 4.1 REFERENCE CONDITIONS Quantities of influence Reference conditions Temperature: 23 C ±2 C Relative humidity: 45% to 75% Supply voltage: 9.0V ±0.5V Frequency range of the applied signal: 45 65Hz Sine wave: pure Peak factor of the applied alternating signal: 2 Position of the conductor in the clamp: centred Adjacent conductors: none Alternating magnetic field: none Electric field: none 33
34 Clamp Multimeter F205 English 4.2 CHARACTERISTICS UNDER THE REFERENCE CONDITIONS The uncertainties are expressed in ± (x% of the reading (R) + y points (pt)) DC voltage measurement Measurement range 0.00 V to 60.0 V to 600 V to 1000 V V V (1) Specified measurement range 0 to 100% of the measurement range Uncertainties from 0.00V to 5.99V ±(1% R + 10 pt) from 6.00V to 59.99V ±(1% R +3 pt) ±(1% R +3 pt) Resolution 0.01V 0.1V 1V Input impedance 10M Note (1) - The display indicates "+OL" above +2000V and "-OL" below 2000V in REL mode - Above 1000V, a repetitive beep indicates that the voltage being measured is greater than the safety voltage for which the device is guaranteed. The display indicates "OL" AC voltage measurement Measurement range Specified measurement range (2) Uncertainties 0.15 V to V from 0.15V to 5.99V ± (1% R + 10 pt) from 6.00V to 59.99V ± (1% R +3 pt) V to V 0 to 100% of the measurement range 600 V to 1000V RMS 1400V peak (1) ± (1% R +3 pt) Resolution 0.01V 0.1V 1V Input impedance 10M Note (1) - The display indicates "OL" above 1000V (1400V in PEAK mode). - Above 1000V, a repetitive beep indicates that the voltage being measured is greater than the safety voltage for which the device is guaranteed. The display indicates "OL". - Bandwidth in AC = 3 khz
35 English Clamp Multimeter F205 Note (2) Any value between zero and the min. threshold of the measurement range (0.15V) is forced to "----" on the display AC+DC voltage measurement Measurement range (2) 0.15 V to V 60.0 V to V 600 V to 1000V RMS (1) 1400V peak Specified measurement range 0 to 100% of the measurement range Uncertainties from 0.15V to 5.99V ± (1% R+10 pt) from 6V to 59.99V ± (1% R +3 pt) ± (1% R +3 pt) Resolution 0.01V 0.1V 1V Input impedance 10M Note (1) - The display indicates "OL" above 1000V (1400V in PEAK mode). - Above 1000V (DC or RMS), a repetitive beep indicates that the voltage being measured is greater than the safety voltage for which the device is guaranteed. - Bandwidth in AC = 3 khz Note (2) - Any value between zero and the min. threshold of the measurement range (0.15V) is forced to "----" on the display. Specific characteristics in MAX/MIN mode in voltage (from 10Hz to 1kHz in AC and AC+DC, and from 0.30V): Uncertainties: add 1% R to the values in the tables above. Capture time of the extrema: approximately 100ms. Specific characteristics in PEAK mode in voltage (from 10Hz to 1kHz in AC and AC+DC): Uncertainties: add 1.5% R to the values in the tables above. PEAK capture time: 1ms min. to 1.5ms max DC current measurement Measurement 0.00 A to 60.0 A to 600 A to 900 A (1) range (2) A A Specified measurement 0 to 100% of the measurement range range Uncertainties (2) ± (1% R+10 ± (1% R +3 pt) (zero corrected) pt) Resolution 0.01A 0.1A 1A 35
36 Clamp Multimeter F205 English Note (1) -The display indicates +OL" above 1800A and "-OL" below 1800A in REL mode. The - and + signs are managed (polarity). Note (2) - The residual current at zero depends on the remanence; It can be corrected by the DC zero function of the HOLD key AC current measurement Measurement range 0.15 A to 60.0 A to 600 A (1) (2) A A Specified 0 to 100% of the measurement range measurement range Uncertainties ± (1% R + 10 pt) ± (1% R +3 pt) Resolution 0.01A 0.1A 1A Note (1) - The display indicates "OL" above 900A in PEAK mode. The "-" and "+" signs are not managed. - Bandwidth in AC = 3 khz Note (2) - Any value between zero and the min. threshold of the measurement range (0.15V) is forced to ---- on the display. - Residual current at zero <150mA AC+DC intensity measurement Measurement range (2) 0.15 A to A 60.0 A to A AC: 600 A DC or PEAK: 600 A to 900 A (1) Specified 0 to 100% of the measurement range measurement range Uncertainties (2) ± (1% R+10 ± (1% R +3 pt) (zero corrected) pt) Resolution 0.01A 0.1A 1A Note (1) - In DC, the display indicates "+OL" above +1800A and "+-OL" above A in REL mode. The "-" and "+" signs are managed (polarity). - In AC and AC+DC, the display indicates "+OL" above 900A in PEAK mode. The "-" and "+" signs are not managed. - Bandwidth in AC = 3 khz Note (2) - In AC, any value between zero and the min. threshold of the measurement range (0.15A) is forced to "----" on the display. - Residual current at zero: 36
37 English Clamp Multimeter F205 In DC: depends on the remanence. Can be corrected by the "DC zero" function of the HOLD key In AC: <150mA Specific characteristics in MAX/MIN mode in current (from 10Hz to 1kHz in AC and AC+DC, and from 0.30 A): Uncertainties: add ± (1% R) to the values in the tables above. Capture time of the extrema: approximately 100ms. Specific characteristics in PEAK mode in current (from 10Hz to 1kHz in AC and AC+DC): Uncertainties: add ± (1.5% R+0.5A) to the values in the tables above. PEAK capture time: 1ms min. to 1.5ms max True-Inrush measurement Measurement range 6 A to 600 A AC 6 A to 900 A DC Specified measurement range 0 to 100% of the measurement range Uncertainties ± (5% R + 5 pt) Resolution 1 A Specific characteristics in PEAK mode in True-Inrush (from 10Hz to 1kHz in AC): Uncertainties: add ± (1.5% R+0.5A) to the values in the tables above. PEAK capture time: 1ms min. to 1.5ms max Continuity measurement Measurement range 0.0Ω to Open-circuit voltage 3,6 V Measurement current 550 µa Uncertainties ± (1% R +3 pt) Buzzer triggering threshold Adjustable from 1Ω to 599 (40 is the default) Resistance measurement Measurement range (1) 0.0 Ω to 600 Ω to 6.00 kω to k 1 to 100% of the Specified measurement 0 to 100% of the measurement measurement range range range Uncertainties ± (1% R +3 pt) Resolution Open-circuit voltage 3,6 V Measurement current 550µA 100µA 10µA 37
38 Clamp Multimeter F205 English Note (1) - Above the maximum display value, the display unit indicates "OL". - The "-" and "+" signs are not managed. Specific characteristics in MAX/MIN mode: Uncertainties: add 1% R to the values of the table above. Capture time of the extrema: approximately 100ms Diode test Measurement range Specified measurement range Uncertainties 0.000V to 3.199V DC 1 to 100% of the measurement range ± (1% R + 3 pt) Resolution 0.001V Measurement current Indication: junction reversed or open-circuit 0.55 ma Display of "OL" when the measured voltage >3.199V Note : The "-" sign is disabled for the diode test function Active DC power measurements Measurement range (2) Specified measurement range Uncertainties (3) 0 W to 5999 W 1 to 100% of the measurement range 6.00 kw to kw 60.0 kw to kw 600 kw to 900 kw (1) 0 to 100% of the measurement range ± (2% R +10 pt) ± (2% R +3 pt) Resolution 1W 10W 100W 1,000W Note (1) - Display of O.L or ± O.L - Above 900kW in single-phase (1000V x 900A). - Above ±1800kW, in REL mode. Note (2) - Any applied voltage greater than 1000V causes the emission of an intermittent alarm beep to report a dangerous overload. Note (3) - The measurement result may be perturbed by an instability linked to the current measurement (approximately 0.1A). Example: for a power measurement made at 10A, the instability of the measurement will be 0.1A/10A or 1%. 38
39 English Clamp Multimeter F Active AC power measurements Measurement range (2) (4) Specified measurement range Uncertainties (3) (7) 5 W to 5999 W 1 to 100% of the measurement range 6.00 kw to kw 60.0 kw to kw 600 kw (1) 0 to 100% of the measurement range ± (2% R +10 pt) ± (2% R +3 pt) Resolution 1W 10W 100W 1000W Note (1) - Display of O.L - Above 600kW in single-phase (1000V x 600A). - Bandwidth in AC in voltage = 3 khz, in current = 3 khz Notes (2) and (3) of the previous apply. Note (4) - Any power measured less than 5W is regarded as zero and causes the display of dashes "----" - If the voltage is less than 0.15V or if the current is less than 0.15A, the power measured is regarded as zero and causes the display of dashes "----" Note 5 - The active powers are positive for power consumed and negative for power generated. Note 6 - The signs of the active and reactive powers and power factor are defined by the four-quadrant rule below: - The diagram below sums up the signs of the power as a function of the phase angle between U and I: Quadrant 1 : Active power P sign + (power consumed) Quadrant 2 : Active power P sign - (power generated) Quadrant 3 : Active power P sign - (power generated) Quadrant 4 : Active power P sign + (power consumed) 39
40 Clamp Multimeter F205 English Note (7) - In balanced three-phases, with deformed signals (THD and harmonics), uncertainties are guaranted since Ф > 30. Additionals errors are following, depending of THD : Add +1% for 10% < THD < 20% Add +3% for 20% < THD < 30% Add +5% for 30% < THD < 40% Active AC+DC power measurements Measurement range (2) (4) Specified measurement range Uncertainties (3) (7) 5 W to 5999 W 1 to 100% of the measurement range 6.00 kw to kw 60.0 kw to kw 600 kw to 900 kw (1) 0 to 100% of the measurement range ± (2% R +10 pt) ± (2% R +3 pt) Resolution 1W 10W 100W 1000W Note (1) - Display of O.L - Above 900kW in single-phase (1000V x 900A). - Bandwidth in AC in voltage = 3 khz, in current = 3 khz Notes (2), (3), (4), 5, 6 and (7) of the previous apply. 40
41 English Clamp Multimeter F Measurement of apparent AC power Measurement 5 VA to 6.00 kva to 60.0 kva to range (2) (4) 5999 VA kva kva 600 kva (1) Specified measurement 1 to 100% of the measurement 0 to 100% of the measurement range range range Uncertainties (3) ± (2% R +10 pt) ± (2% R +3 pt) Resolution 1VA 10VA 100VA 1000VA Note (1) - Display of O.L - Above 600 kva in single-phase (1000 V x 600 A). - Bandwidth in AC in voltage = 3 khz, in current = 3 khz Notes (2), (3) and (4) of the previous apply Measurement of apparent AC+DC power Measurement range (2) (4) 5 VA to 5999 VA 6.00 kva to kva 60.0 kva to kva 600 kva to 900 kva (1) Specified 1 to 100% of the measurement measurement range range 0 to 100% of the measurement range Uncertainties (3) ± (2% R +10 pt) ± (2% R +3 pt) Resolution 1VA 10VA 100VA 1000VA Note (1) - Display of O.L - Above 900 kva in single-phase (1000 V x 900 A). - Bandwidth in AC in voltage = 3 khz, in current = 3 khz Notes (2), (3) and (4) of the previous apply. 41
42 Clamp Multimeter F205 English Measurement of reactive AC power Measurement range (2) (4) Specified measurement range Uncertainties (3) (8) 5 var to 5999 var 1 to 100% of the measurement range 6.00 kvar to 59,99 kvar kvar to kvar 600 kvar (1) 0 to 100% of the measurement range ± (2% R +10 pt) ± (2% R +3 pt) Resolution 1 var 10 var 100 var 1000 var Note (1) - Display of O.L - Above 600 kvar in single-phase (1000 V x 600 A). - Bandwidth in AC in voltage = 3 khz, in current = 3 khz Notes (2), (3) and (4) of the previous apply. Note 5 - In single-phase, the sign of the reactive power is determined by the phase lead or lag between the U and I signs, while in balanced threephase, it is determined by the calculation on the samples. Note 6 - Signs of reactive powers according to the four-quadrant rule ( ): Quadrant 1 : Reactive power Q sign + Quadrant 2 : Reactive power Q sign + Quadrant 3 : Reactive power Q sign - Quadrant 4 : Reactive power Q sign Note (8) - In single phase, with deformed signals (THD and harmonics), uncertainties are guaranted since Ф > 30. Additionals errors are following, depending of THD : Add +1% for 10% < THD < 20% Add +3% for 20% < THD < 30% Add +5% for 30% < THD < 40% Measurement of reactive AC+DC power Measurement range (2) (4) Specified measurement range Uncertainties (3) (8) 5 var to 5999 var 1 to 100% of the measurement range 6.00 kvar to kvar 60.0 kvar to kvar 600 kvar to 900 kvar (1) 0 to 100% of the measurement range ± (2% R +10 pt) ± (2% R +3 pt) Resolution 1 var 10 var 100 var 1000 var
43 English Clamp Multimeter F205 Note (1) - Display of O.L - Above 900 kvar in single-phase (1000 V x 900 A). - Bandwidth in AC in voltage = 3 khz, in current = 3 khz Notes (2), (3), (4), 5, 6 and (8) of the previous apply. Specific characteristics in MAX/MIN mode in power (from 10Hz to 1kHz): Uncertainties: add 1% R to the values in the tables above. Capture time: approximately 100ms Calculation of the power factor Measurement range (1) to Specified measurement range 0 to 50% of the measurement range 50 to 100% of the measurement range Uncertainties (7) ± (3% R +3 pt) ± (2% R +3 pt) Resolution 0.01 Note (1) - If one of the terms in the calculation of the power factor is displayed as "OL", or forced to zero, the display of the power factor is an indeterminate value "----". Note (7) of the previous apply. Note 9 - Sign of the power factor according to the four-quadrant rule ( ): Quadrant 1 : Power factor PF sign + (inductive system) Cos Φ sign + Quadrant 2 : Power factor PF sign - (capacitive system) Cos Φ sign - Quadrant 3 : Power factor PF sign + (inductive system) Cos Φ sign - Quadrant 4 : Power factor PF sign - (capacitive system) Cos Φ sign + Specific characteristics in MAX/MIN mode (from 10Hz to 1kHz): Uncertainties: add 1% R to the values in the tables above. Capture time: approximately 100ms. 43
44 Clamp Multimeter F205 English Frequency measurements Characteristics in voltage Measurement range (1) 5.0 Hz to 600 Hz to 6.00 khz to Hz 5999 Hz khz 1 to 100% of the Specified measurement 0 to 100% of the measurement measurement range range range Uncertainties ± (0.4% R + 1 pt) Resolution 0.1Hz 1Hz 10Hz Characteristics in current Measurement range (1) Specified measurement range Uncertainties Resolution 5.0 Hz to 2999 Hz 1 to 100% of the measurement range ± (0.4% R + 1 pt) 0.1Hz Note (1) in MAX/MIN mode, the operating range is limited to 1kHz. - If the level of the signal is too low (<10% of the range, or U<10V or I<10A) or if the frequency is less than 5Hz, the device cannot determine the frequency and displays dashes "----". Specific characteristics in MAX/MIN mode (from 10Hz to 1kHz): Uncertainties: add 1% R to the values of the table above. Capture time of the extrema: approximately 100ms Characteristics in THDr Measurement range % Specified measurement range 0 to 100% of the measurement range Uncertainties ± (5% R ±2 pts) in voltage ± (5% R ±5 pts) in current Resolution 0.1% Characteristics in THDf Measurement range % Specified measurement range 0 to 100% of the measurement range Uncertainties ± (5% R ±2 pts) in voltage ± (5% R ±5 pts) in current Resolution 0.1% 44
45 English Clamp Multimeter F205 Note : - The display is "----" if the input signal is too low (U<5V or I<6A) or if the frequency is less than 5Hz. Specific characteristics in MAX/MIN mode in THD (from 10Hz to 1kHz): Uncertainties: add 1% R to the values in the tables above. Capture time of the extrema: approximately 100ms Indication of order of the phases Frequency range 47Hz to 400Hz Acceptable voltage range 50V to 1,000V Duration of acquisition of the reference period Duration of validity of the reference period information Duration of acquisition of the measurement period + display of the order of the phases Acceptable phase unbalance 500ms approximately 10s at 50Hz approximately 2s to 400Hz 500ms 10 Acceptable amplitude unbalance 20% Acceptable level of harmonics in voltage 10% 4.3 ENVIRONMENTAL CONDITIONS Environmental conditions in use in storage Temperature -20 C to + 55 C -40 C to + 70 C Relative humidity (RH): 90% at 55 C 90% up to 70 C 45
46 Clamp Multimeter F205 English 4.4 CHARACTERISTICS OF CONSTRUCTION Housing: Jaws: Screen: Dimension: Weight: Rigid polycarbonate shell with moulded elastomer covering Polycarbonate Opening: 34 mm Clamping diameter: 34 mm LCD display unit Blue backlighting Dimension: 28 x 43.5 mm H-222 x W-78 x D-42 mm 340g (with the battery) 4.5 POWER SUPPLY Batter: Mean life: Duration of operation before automatic switching off: 1 x 9 V LF22 >120 hours (without backlighting) After 10 minutes without action on the switch and/or keys 4.6 COMPLIANCE WITH INTERNATIONAL STANDARDS Electric safety: Electromagnetic compatibility: Mechanical strength: Level of protection of the housing: Compliant with standards IEC , IEC , and IEC : 1000V CAT-III or 600V CAT IV. Compliant with standard EN Classification: residential environment Free fall: 2m (in accordance with standard IEC ) IP40 (per standard IEC-60529) 46
47 English Clamp Multimeter F VARIATIONS IN THE DOMAIN OF USE Quantity of influence Temperature Humidity Frequency Position of the conductor in the jaws (f 400 Hz) Adjacent conductor carrying a current of 150 A DC or RMS Conductor enclosed by the clamp Application of a voltage of the clamp Peak factor Range of influence C 10%...90%HR 10 Hz...1 khz 1 khz...3 khz 10 Hz 400 Hz 400 Hz 3 khz Any position on the internal perimeter of the jaws Conductor touching the external perimeter of the jaws A DC or RMS V DC or RMS 1,4 to 3,5 limited to 900 A peak 1400 V peak Quantity Influence influenced Typical MAX V AC V DC A W AC W DC V A W V A - 0,1%R/10 C 1%R/10 C - - 0,15%R/10 C 1 pt - 0,2%R 0,25%R 1%R + 1 pt 8%R + 1 pt 1%R + 1 pt 4%R + 1 pt 0,1%R/10 C 0,5%R/10 C + 2pts 1,5%R/10 C + 2pts 0,1%R/10 C + 2 pts 0,2%R/10 C + 1 C 0,3%R/10 C + 2 pts 0,1%R + 1 pt 0,1%R + 2 pts 0,3%R + 2 pts 0,5%R + 2 pts 1%R + 1 pt 9%R + 1 pt 1%R + 1 pt 5%R + 1 pt A-W 3%R 4%R + 1 pt A-W 45 db 40 db V < 1 pt 1 pt A-W 1 pt 1 pt A (AC-AC+DC) V (AC-AC+DC) 1%R 1%R 3%R + 1 pt 3%R + 1 pt 47
48 Clamp Multimeter F205 English 5 MAINTENANCE The instrument has no parts that can be replaced by personnel who are not trained and approved. Any non-approved repair or other work, or replacement of a part by an "equivalent", may severely compromise safety. 5.1 CLEANING Disconnect everything connected to the device and set the switch to OFF. Use a soft cloth moistened with soapy water. Rinse with a damp cloth and dry quickly using a dry cloth or forced air. Dry perfectly before putting back into use. 5.2 REPLACEMENT OF THE BATTERY The symbol indicates that the battery is spent. When this symbol appears on the display unit, the battery must be replaced. The measurements and specifications are no longer guaranteed. To replace the battery, proceed as follows: 1. Disconnect the measurement leads from the input terminals. 2. Set the switch to OFF. 3. Use a screwdriver to unscrew the screw securing the battery compartment cover to the back of the housing and open the cover (see 3.1). 4. Replace the battery (see 3.1). 5. Close the cover and screw it to the housing. 5.3 METROLOGICAL CHECK Like all measuring or testing devices, the instrument must be checked regularly. This instrument should be checked at least once a year. For checks and calibrations, contact one of our accredited metrology laboratories (information and contact details available on request), at our Chauvin Arnoux subsidiary or the branch in your country. 5.4 REPAIR For all repairs before or after expiry of warranty, please return the device to your distributor. 48
49 English Clamp Multimeter F205 6 WARRANTY Except as otherwise stipulated, our warranty is valid for three years starting from the date on which the equipment was sold. Extract from our General Conditions of Sale provided on request. The warranty does not apply in the following cases: Inappropriate use of the equipment or use with incompatible equipment; Modifications made to the equipment without the explicit permission of the manufacturer s technical staff; Work done on the device by a person not approved by the manufacturer; Adaptation to a particular application not anticipated in the definition of the equipment or not indicated in the user s manual; Damage caused by shocks, falls, or floods. 7 DELIVERY CONDITION The F205 clamp multimeter is delivered in its packaging box with : 2 banana-banana leads, one red and one black 2 test probes, one red and one black 1 black crocodile clip 1 9V batteries 1 carrying bag the multiligual user manual on mini-cd the multiligual getting started guide 49
50 Code : A02 - Ed. 2 DEUTSCHLAND - Chauvin Arnoux GmbH Straßburger Str Kehl / Rhein Tel: (07851) Fax: (07851) ESPAÑA - Chauvin Arnoux Ibérica SA C/ Roger de Flor N 293, Planta Barcelona Tel: Fax: ITALIA - Amra SpA Via Sant Ambrogio, 23/ Bareggia di Macherio (MI) Tel: Fax: ÖSTERREICH - Chauvin Arnoux Ges.m.b.H Slamastrasse 29/2/ Wien Tel: Fax: SCANDINAVIA - CA Mätsystem AB Box SE TÄBY Tel: Fax: SCHWEIZ - Chauvin Arnoux AG Moosacherstrasse AU / ZH Tel: Fax: UNITED KINGDOM - Chauvin Arnoux Ltd Unit 1 Nelson Court Flagship Square-Shaw Cross Business Park DEWSBURY West Yorkshire WF12 7TH Tel : Fax : MIDDLE EAST - Chauvin Arnoux Middle East P.O. BOX JAL EL DIB (Beirut) LEBANON Tel: (01) Fax: (01) CHINA - Shanghai Pu-Jiang - Enerdis Instruments Co. Ltd 3 F, 3 rd Building - N 381 Xiang De Road SHANGHAI Tel: Fax: USA - Chauvin Arnoux Inc - d.b.a AEMC Instruments 200 Foxborough Blvd. - Foxborough - MA Tel: (508) Fax: (508) , rue Championnet PARIS Cedex 18 - FRANCE Tél. : Fax : [email protected] Export : Tél. : Fax : [email protected]
UT202A Operating Manual. Contents
Title Contents Page Overview Unpacking Inspection Safety Information Rules for Safe Operation International Electrical Symbols The Meter Structure Functional Buttons and auto power off Display Symbols
Model UT201/202: OPERATING MANUAL. Table of Contents
Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons The Effectiveness
Model UT33A: OPERATING MANUAL Table of Contents (1)
Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter structure Functional Buttons LCD Display Measurement Operation
User's Guide. True RMS Industrial Multimeter
User's Guide 97650 True RMS Industrial Multimeter Ω C ã F ã 10A V µ 10A V ã ã ma A Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12
Table of Contents The Basics of Electricity 2 Using a Digital Multimeter 4 IDEAL Digital Multimeters An Introduction The Basics of Digital Multimeters is designed to give you a fundamental knowledge of
Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)
Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter structure Functional Buttons Measurement Operation A. DC
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Digital Clamp-on DMMs with uncompromising performance
Digital Clamp-on DMMs with uncompromising performance With this new range of clamp-on meters, Metrix introduces practical and inexpensive instruments with uncompromising performance. Designed to satisfy
User Guide. Model 380260 Insulation Tester / Megohmmeter
User Guide Model 380260 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380260 provides three test ranges plus continuity
Manual Ranging MultiMeter
Owner s Manual Manual Ranging MultiMeter Model 82345 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.! Safety! Operation! Maintenance!
Power Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration
Model 8220. POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter
Special product features '''' ENERGY METER ''' MEASURES RPM POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Model A measurement tool for electrical parameters and distribution network disturbances
Model UT58A/B/C: OPERATING MANUAL
Table of Contents Title Page Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons Display Symbols
1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.
1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter
72-7730 72-7732 Intelligent Digital Multimeters
72-7730 72-7732 Intelligent Digital Multimeters Model 72-7730/72-7732 OPERATING MANUAL TABLE OF CONTENTS CHAPTER TITLE PAGE 1. Before You Start Overview Inspection Safety Information Rules For Safe Operation
3U 4V 4A L1 L2 L3 V2 = 314 V3 = -84 N = -14 > ensuring high performance C.A 8332B C.A 8334B C.A 8335 POWER AND ENERGY QUALITY ANALYSERS
v 3 9. v C.A 833B C.A 8334B C.A 8335 9.3 v The experience of the Qualistar ensuring high performance POWER AD EERGY QUALITY AALYSERS 3U 4V 4A L1 L L3 Measure all the necessary voltage, current and power
Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011
Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.
AutoRanging Digital MultiMeter
Owner's Manual AutoRanging Digital MultiMeter Model No. 82139 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
Ground Resistance Clamp On Tester
USER MANUAL Ground Resistance Clamp On Tester MODEL 382357 Introduction Congratulations on your purchase of Extech s 382357 Ground Resistance Tester. This Clamp on device allows the user to measure ground
EPM3. Phase Sequence and Motor Rotation Tester. Users Manual
EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR
The Basics of Digital Multimeters
IDEAL INDUSTRIES INC. The Basics of Digital Multimeters A guide to help you understand the basic Features and Functions of a Digital Multimeter. Author: Patrick C Elliott Field Sales Engineer IDEAL Industries,
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
HVAC Clamp Meter. Users Manual
902 HVAC Clamp Meter Users Manual PN 2547887 May 2006 Rev. 1, 3/07 2006-2007 Fluke Corporation. All rights reserved. Printed in China. All product names are trademarks of their respective companies. LIMITED
Energy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
What is a multimeter?
What is a multimeter? A multimeter is a devise used to measure voltage, resistance and current in electronics & electrical equipment It is also used to test continuity between to 2 points to verify if
INSTRUCTION MANUAL IPM 3600 3 Phase Power Analyser EN FR IT DE ES
INSTRUCTION MANUAL IPM 3600 3 Phase Power Analyser EN FR IT DE ES CONTENTS / EN CONTENTS Title Page I. SAFETY INFORMATION...1 II. INTRODUCTION...3 III. SPECIFICATIONS...4 3-1 Environmental Conditions...4
Model UT71A/B OPERATING MANUAL
Model UT71A/B OPERATING MANUAL CHAPTER TITLE PAGE 1. 2. Before You Start Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols Getting Acquainted Turning
Instructions A622 100 Amp AC/DC Current Probe 070-8883-03
Instructions A622 100 Amp AC/DC Current Probe 070-8883-03 Revision A www.tektronix.com 070888303 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,
i410/i1010 AC/DC Current Clamp
/i1010 AC/DC Current Clamp Instruction Sheet Safety Information XW Read First: Safety Information To ensure safe operation and service of the current clamp, follow these instructions: Read all operating
Panel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
10 Multimeter. Users Manual
10 Multimeter Users Manual 1991-2001 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies. 10 MULTIMETER m m Mk SELECT RANGE OFF VDC VAC
Digital Ground Resistance Tester. Models 4620 & 4630. Digital Ground Resistance Tester
Digital Ground Resistance Tester Models 4620 & 4630 Digital Ground Resistance Tester Models 4620 and 4630 perform both ground resistance and soil resistivity tests. These testers measure from 0 to 2000Ω,
5000V Graphical Megohmmeter Model 5070
5000V Graphical Megohmmeter Model 5070 The Model 5070, the latest design in 5000V Megohmmeters, is the most innovative product in its class on the market today. The features and functions incorporated
Fluke 3000 FC Series Test Tools Technical Data
Fluke 3000 FC Series Test Tools Technical Data Now compatible with Fluke Connect Mobile App Start building tomorrow s test tool system today with the Fluke 3000 FC Digital Multimeter. The new Fluke Connect
How To Use A Cdm250 Digital Multimeter
User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this
Model UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents
P/N:110401103671 Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons
ENERGY AUDITING AND MONITORING IN COMPANIES
ENERGY AUDITING AND MONITORING IN COMPANIES Introduction To implement Article 8 (-6) of the EU Energy Efficiency Directive (0/7/EU), the UK government has set up ESOS (Energy Savings Opportunity Scheme)
Table of Contents. Page 3 4 5 6 8 9 10 11 13 13 14 16 17 19
Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Multimeter Structure Functional Buttons Display Symbols Measurement
User Guide. www.burntec.com. 4 wire Earth Resistance Tester Model GRT300
User Guide 4 wire Earth Resistance Tester Model GRT300 Introduction Congratulations on your purchase of Extech s 4 Wire Earth Resistance Tester. The Model GRT300 has been designed and tested according
Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL
Auto-ranging Digital Multimeter 52-0052-2 INSTRUCTION MANUAL WARNING: READ AND UNDERSTAND THIS MANUAL BEFORE USING YOUR MULTIMETER. FAILURE TO UNDERSTAND AND COMPLY WITH WARNINGS AND OPERATING INSTRUCTIONS
323/324/325. Calibration Manual. Clamp Meter
323/324/325 Clamp Meter Calibration Manual February 2013 2012 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective
Model UT60A: OPERATING MANUAL. Table of Contents. Page 3 4 5 6 8 9 10 11 14 17 17 17 19 19
Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons Display Symbols Measurement
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
Three phase circuits
Three phase circuits THREE PHASE CIRCUITS THREE-PHASE ADVANTAGES 1. The horsepower rating of three-phase motors and the kva rating of three-phase transformers are 150% greater than single-phase motors
User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters
SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm
R448 & R448 V50 A.V.R.
Armature + 6- This manual is to be given to the end user F1 ST5 Field Slow fuse 250V 10 A with LAM without LAM 10 Yellow 11 Red 12 Black 9 Green X2 Z1 X1 Z2 E+ E- 0V 110 22 ST3 requency ST10 50Hz 60Hz
Pocket Tach 99 (PT99) Non-Contact Tachometer
CE DECLARATION OF CONFORMITY As Manufacturer: Monarch Instrument Division of Monarch International Inc. 15 Columbia Drive, Amherst NH 03031 USA declares under Monarch s sole responsibility that the product:
max 6f / computer max
POWER FACTOR REGULATORS computer max max 6f / computer max max 12f Instructions Manual ( M98234601-03-10A ) - 1 - Index 1 INTRODUCTION AND SAFETY RECOMMENDATIONS... 3 1.1 DELIVERY SPOT CHECK... 3 1.2 STARTING
Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE
Understanding Power Factor and How it Affects Your Electric Bill Presented by Scott Peele PE Understanding Power Factor Definitions kva, kvar, kw, Apparent Power vs. True Power Calculations Measurements
Loop and earth Ohmmeter C.A 6456
Loop and earth Ohmmeter C.A 6456 E N G L I S H User's manual 1 Meaning of the symbol : WARNING! Consult the user manual before using the instrument. Failure to follow or carry out the instructions in this
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
Microwave Meter. Instruction Manual
Microwave Meter 840046 Instruction Manual Microwave Meter 840046 Copyright 2009 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted
C.A 8230 ENGLISH. Operating manual
SINGLE-PHASE POWER QUALITY ANALYSER C.A 8230 ENGLISH Operating manual 1 Meaning of the symbol. Attention: refer to the operating manual before using the instrument. Failure to properly observe or execute
HOW TO USE MULTIMETER. COMPILE BY: Dzulautotech
HOW TO USE MULTIMETER COMPILE BY: Dzulautotech 1. GENERAL Electricity is absolutely necessary for an automobile. It is indispensable when the engine is started, the air fuel mixture is ignited and exploded,
Keysight N4877A Clock Data Recovery and Demultiplexer 1:2
Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 Getting Started Getting Started with the Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 You only need a few minutes to get started
Fluke Digital Multimeters Solutions for every need
Fluke Digital Multimeters Solutions for every need How to choose the best DMM for your job Choosing the right digital multimeter (DMM) requires thinking about what you ll be using it for. Evaluate your
1. SAFETY INFORMATION
RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter
Current Monitoring Kit QUICK START GUIDE
Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Ground Resistance Clamp-On Tester
User s Manual Ground Resistance Clamp-On Tester MODEL 382357 Warranty EXTECH INSTRUMENTS CORPORATION (a FLIR company) warrants the basic instrument to be free of defects in parts and workmanship for one
T 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
Current Monitoring Kit
Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added
Dual Display Digital Multimeter
Dual Display Digital Multimeter GDM-8246 GW INSTEK PART NO. 82DM-82460MG1 This manual contains proprietary information, which is protected by copyrights. All rights are reserved. No part of this manual
User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger
RD2000: SuperC.A.T + SuperC.A.T TL SuperC.A.T S SuperC.A.T CPS T1 Transmitter User Guide
RD000 SuperC.A.T RD000: SuperC.A.T + SuperC.A.T TL SuperC.A.T S SuperC.A.T CPS T Transmitter User Guide RD000 SuperC.A.T User Guide Functions SuperC.A.T Locator functions 4 6 On/Off Trigger. Press and
DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D
ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
Simple Logger II Data Loggers
TRMS CLAMP-ON AC CURRENT AC VOLTAGE DC CURRENT DC VOLTAGE THERMOCOUPLE TEMP/RH EVENT LOGGER Simple Logger II Data Loggers E N G L I S H User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a.
H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.
Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.
LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems
LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems TDB301021en/06.2013 LIETRAXX -A etwork and system protection (S protection) for monitoring
Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
www.elektroexpressz.hu
www.elektroexpressz.hu 2013 1 UT10 SERIES / UT20 SERIES Modern Pocket - Size Digital Multimeters Pocket-Size Digital Multimeters UNI-T UT10A UT10A DC Voltage 400mV/4V/40V/300 ±(0.8%+1) AC Voltage 4V/40V/300V
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
7. Reactive energy compensation
593 7. Reactive energy compensation 594 7. REACTIVE ENERGY COMPENSATION Reactive energy compensation is an important element for reducing the electricity bill and improving the quality of the electrical
Model UT713 OPERATING MANUAL
Model UT713 OPERATING MANUAL TABLE OF CONTENTS TITLE PAGE Introduction Unpacking Inspection Safety Information Turning the Calibrator On Simulating a Thermocouple Measuring a Thermocouple Simulating TC
Problem / Solution. The problem:
Problem / Solution Solar Photovoltaic (PV) technology has shown significant development in recent years and this has led to many UK homeowners investing in Solar PV installations. Solar electricity is
Integrating Sound Level Meter and Datalogger
USER GUIDE Integrating Sound Level Meter and Datalogger Model 407780A Introduction Thank you for selecting the Extech Instruments Model 407780A. This device is shipped fully tested and calibrated and,
Water Leak Detection System
Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:[email protected] 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
SOUND LEVEL METER 94405
SOUND LEVEL METER 94405 INSTRUCTION MANUAL REC FAST A/C 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter only as specified
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM
EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273
Contactless Encoder RI360P0-QR24M0-INCRX2-H1181
Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.
Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document
By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By the Authority Vested By Part 5 of the United States Code 552(a) and Part 1 of the Code of Regulations 51 the attached document has
Multi Media Cable Tester TM-901N/TM-902/TM-903
Multi Media Cable Tester TM-901N/TM-902/TM-903 User Manual HB2TM9020010 TENMARS ELECTRONICS CO., LTD Table of Contents 1 Introduction... 1 2 Safety Precaution... 1 3 The verifier does the following:...
INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
Fig. 1 Analogue Multimeter Fig.2 Digital Multimeter
ELECTRICAL INSTRUMENT AND MEASUREMENT Electrical measuring instruments are devices used to measure electrical quantities such as electric current, voltage, resistance, electrical power and energy. MULTIMETERS
162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL
162 CB CABLE TRACER Filter Probe & Tone Generator INSTRUCTION MANUAL INDEX PAGE 1. INTRODUCTION... 1 2. FILTER PROBE... 1-3 3. TONE GENERATOR... 3-6 4. SPECIFICATION... 7-8 5. MAINTENANCE... 8 1. INTRODUCTION
User s manual FLIR VP50/VP52 Non-contact AC voltage detector
User s manual FLIR VP50/VP52 Non-contact AC voltage detector User s manual FLIR VP50/VP52 #T559851; r. AD/ 9134/9134; en-us Table of contents 1 Disclaimers... 1 1.1 Copyright... 1 1.2 Quality assurance...
EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS
1 EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS The oscilloscope is the most versatile and most important tool in this lab and is probably the best tool an electrical engineer uses. This outline guides